You are on page 1of 1

7

A Division of Illinois Tool Works Inc.

PENETRANT PROCESS GUIDE

Method A: WATER WASH FOR FLUORESCENT INSPECTION

DCN-282 Aerospace DCN-200 Non-Spec DCN-236 Neutral

ZL-15B Level 1/2 ZL-19 Level 1 ZL-60D Level 2 ZL-67 Level 3 ZL-56 Level 4
APPLY PENETRANT DWELL TIME 10-30 Minutes (in some cases longer) RINSE 50 - 100 F (10 - 38 C) at <40 psi

PRECLEAN WITH DARACLEAN

ZP-5B Water Suspendible

APPLY AQUEOUS DEVELOPER

DRY at 140 F (60 C)

DWELL TIME 10 min. - 2 hrs. max.

INSPECT

ZP-4B Dry Developer

DRY at 140 F (60 C)

APPLY DRY DEVELOPER

DWELL TIME 10 min. - 4 hrs. max.

MAGNAFLUX . 3624 West Lake Avenue . Glenview, Illinois 60026 . (847) 657-5300 . cs@magnaflux.com . www.magnaflux.com