You are on page 1of 4

8.

3 Cable
Following table shows cables for PNMS connection. In accordance with customers
network configuration, the selection of suitable cable is required.
Cable Name

How to use

Pin Assignment Drawing #

LCT

Figure 8.5

Figure 8.6

182-228614

PNMT

Figure 8.7

Figure 8.8

182-228615

PNMT+LCT

Figure 8.9

Figure 8.10

182-228617

Figure 8.11,8.12

Figure 8.13

182-228616

-RS232C

Figure 8.14

Figure 8.15

182-228618

-RS485

Figure 8.14

Figure 8.16

182182-228619
228619

(1)

Figure 8.17

Figure 8.18

182182-228620
228620

(2)

Figure 8.17

Figure 8.19

182182-228622
228622

(3)

Figure 8.17

Figure 8.20

182
182-228623

(1)

Figure 8.21

Figure 8.22

182-229766

(2)

Figure 8.21

Figure 8.23

182-228622

(3)

Figure 8.21

Figure 8.24

182-228623

-RS232C

Figure 8.25

Figure 8.26

UNDER DRAFT

-RS422

Figure 8.25

Figure 8.27

UNDER DRAFT

(1)

Figure 8.28

Figure 8.29

UNDER DRAFT

(2)

Figure 8.28

Figure 8.30

182-228622

PNMS
Back to Back (Point to point)

Back to Back (Point to multi-point)

PNMS+Back to Back (Point to multi-point)

HYB CONV-PASOLINK (point to point)

HYB CONV-PASOLINK (point to multi-point)

Table 8.15 Cable List

PNMS Engineering manual


-1-

8.3.5 Back to Back Cable (Point to Point)

RPM

CPM

RPM

RPM
NMS Port

NMS Port

182-228618 (RS232C)
182-228619 (RS485)

Figure 8.14 Back-to-Back (point to point) connection

15pin(M)

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

(182-228619)
Figure8.16 Pin assignment for back to back
(point to point, RS485) connection

PNMS Engineering manual


-2-

8.3.6 Back to Back Cable (Point to Multi-point)

CPM

SCPM
F

NMS Port
[RS485]

182-228620

RPM

RPM

RPM

SCPM

NMS Port
[RS485]

NMS Port
[RS485]

182-228622

182-228623
F

182-228622

Put on the Termination M at the end of connections

15pin(F)

15pin(M)

Figure8.17 Back to Back Cable (point to Multi-point) connection

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228620)
Figure8.18 Pin assignment for back to back (point to multi-point) connection (1)
Using with Cascade connection cable (182-228622)

PNMS Engineering manual


-3-

0.5 to 15m

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

0.3m

15pin(M)

15pin(F)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

(182-228622)
Figure8.19 Pin assignment for back to back (point to multi-point) connection (2)
(Cascade connection Cable)

15pin(M)

RS-485
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

EMS-TXD+
EMS-TXDEMS-TXDR
EMS-RXD+
EMS-RXDGND

NMS-TXD+
NMS-TXDNMS-TXDR
NMS-RXD+
NMS-RXD-

(182-228623)
Figure8-20 Pin assignment for back to back (point to multi-point) connection (3)
(Termination connector)

PNMS Engineering manual


-4-

You might also like