Professional Documents
Culture Documents
Systemkabel, Frontadapter und bergabemodule System Cables, Front Adapter and Termination Boards
www.phoenixcontact.net/yokogawa
System Cabling
System Cables and Termination Boards for YOKOGAWA CENTUM CS3000R3 CENTUMVP INTERFACE
Phoenix Contact 12/2012
Contents
Cross Reference List....3 Termination Boards..5
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 2 of 202
05/12/2012
Analog I/O
AAB841 (1 to 5 V Input, 4 to 20 mA Output, Non-Isolated)
Analog I/O
NFAB841 (1 to 5 V Input, 4 to 20 mA Output, Non-Isolated)
Description
191
191
2314 CABLE-50/4FLK14/.../YUC
194
2306 FLKMIL-50/4FLK14/EZ-DR/.../CS
197
2314 FLK-MIL-50/EZ-DR/KS/.../YCS
199
23213 CABLE-40/2FLK16/.../YUC
201
2319427 UM-2KS50/UNI/CS
140
128
2*Y
2*Y
2*Y
2*Y
2311399 UM-2KS50/UNI/CS/Z/SO180
140
128
2*Y
2*Y
2*Y
2*Y
2314451 FLKMS-KS50/32IM/YCS
174
90
2*Y
2*Y
2*Y
2*Y
2901896 FLKMS-2KS50/32IM/YCS
179
111 10
2*Y
2*Y
2*Y
2*Y
2314464 FLKM-KS50/SI/YCS
350
90 14
2*Y
2*Y
2*Y
2*Y
2901013 UM-2KS50/DI32/CS/SO180
ADV151, ADV161
NFDV151, NFDV161
216
128 17
2*Y
2*Y
2311360 UM-2KS50/DI32/CS/Z/SO180
ADV151, ADV161
NFDV151, NFDV161
216
128 20
2*Y
2*Y
2321884 FLKM-2KS50/PMT/ADV151/YCS
ADV151, ADV161
NFDV151, NFDV161
233
126 23
2*Y
2*Y
2321923 FLKM-2KS50/PMT/ADV151/Z/YCS
ADV151, ADV161
NFDV151, NFDV161
233
126 27
2*Y
2*Y
2321813 FLKM-2KS50/BFI/SPT/CS
344
126 31
2*Y
2*Y
2*Y
2*Y
2321842 FLKM-2KS50/BFI/SPT/CS/C-L
344
126 31
2*Y
2*Y
2*Y
2*Y
2900162 FLKM-2KS50/BFI/MKDS/CS
344
126 35
2*Y
2*Y
2*Y
2*Y
2296553 PLC-V8/FLK14/IN
ADV151, ADV161
NFDV151, NFDV161
49,6
94 39
4*O
8*Q
4*O
8*Q
6,2
80 39
ADV151, ADV161,
NFDV151, NFDV161
231
128 42
2*Y
2*Y
2900898 UM-KS50/32MR/1/ADV151/SC/SO207
ADV151, ADV161,
NFDV151, NFDV161
233
128 46
2*Y
2*Y
2310222 UM-2KS50/32-MR/21/ADV151/SO179
ADV151, ADV161,
NFDV151, NFDV161
520
128 50
2*Y
2*Y
2968506 UM-32NAM/I/M/YCS
ADV151, ADV161
NFDV151, NFDV161
224
128 53
2*Y
2*Y
2304102 PLC-V8/FLK14/OUT/M
ADV551, ADV561
NFDV551, NFDV561
49,6
94 57
4*O 8*Q
4*O 8*Q
6,2
80 58
2969055 UMK-32RM/MR-G24/1/YCS
ADV551, ADV561
NFDV551, NFDV561
202
90 60
2*Y
2*Y
ADV551, ADV561
NFDV551, NFDV561
268
128 63
2*Y
2*Y
2900899 UM-KS50/32MR/1/ADV551/SC/SO207
ADV551, ADV561
NFDV551, NFDV561
233
128 67
2*Y
2*Y
2311373 UM-2KS50/DO32REL/CS/SO180
ADV551, ADV561
NFDV551, NFDV561
240
128 71
2*Y
2*Y
ADV551, ADV561
NFDV551, NFDV561
520
128 74
2*Y
2*Y
2968564 UM-2KS50RM/32MR/SI/1/ADV551/MT
ADV551, ADV561
NFDV551, NFDV561
420
128 78
2*Y
2*Y
2968551 UM-2KS50RM/32MR/SI/1/ADV551/Z/MT
ADV551, ADV561
NFDV551, NFDV561
420
128 82
2*Y
2*Y
2968519 UM-2KS50/32RM/MR/21/SPT/CS
ADV551, ADV561
NFDV551, NFDV561
506
128 86
2*Y
2*Y
2968535 UM-2KS50/32RM/MR/21/SPT/CS/C-L
ADV551, ADV561
NFDV551, NFDV561
506
128 86
2*Y
2*Y
2900163 UM-2KS50/32RM/MR/21/MKDS/CS
ADV551, ADV561
NFDV551, NFDV561
506
128 90
2*Y
2*Y
2311166 UM-2KS50/4FLK14/YCS
78
128 94
2*Y
2*Y
2*Y
2*Y
2968522 UM-4SL/SPT/ADR541/CS
ADR541
233
128 98
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 3 of 202
05/12/2012
12 channel isolated)
Dimensions (B | T) in mm
Spring-cage connection
Centum CS 3000 R3
Knife disconnectIion
Screw connection
AAR181(PT100
Stardom
Order No.
Page
Analog I/O
AAB841 (1 to 5 V Input, 4 to 20 mA Output, Non-Isolated)
Analog I/O
NFAB841 (1 to 5 V Input, 4 to 20 mA Output, Non-Isolated)
Description
2968548 UM-4SL/SPT/ADR541/CS/C-L
ADR541 NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835 NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835 NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835 NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835 NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835 NFAI141, NFAI143, NFAI543, NFAI841, NFAB841, NFAV542, NFAV141, NFAV142 NFAI141, NFAI143, NFAI543, NFAI841, NFAB841, NFAV542, NFAV141, NFAV142
233
128 98
2314642 FLKM-KS40/YCS
AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841 AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841 AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841 AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841 AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841 AAI141, AAI143, AAV141, AAV142, AAI543, AAV542, AAI841, AAB841
112
90 102
2314752 FLKM-2KS40/YCS/ZFKDS
100
126 106
2901056 FLKM-2KS40/YCS
100
126 110
2321826 FLKM-2KS40/SPT/CS
195
126 114
2321855 FLKM-2KS40/SPT/CS/C-L
195
126 114
2321981 FLKM-2KS40/PMT/ST/YCS
180
111 119
2321994 FLKM-2KS40/PMT/ST/Z/YCS
180
111 126
2311331 UM-2KS40/AI16/CS/Z/SO180
AAI141, AAI143
NFAI141, NFAI143
163
128 133
2314286 FLKMS-KS40/AI16/YCS
AAI141, AAI143
NFAI141, NFAI143
214
126 136
2314710 FLKMS-KS40/AI16/YCS/ZFKDS
AAI141, AAI143
NFAI141, NFAI143
214
126 139
2314273 FLKMS-KS40/SI/AI16/YCS
214
126 142
2314260 FLKM-KS40/AO16/YCS
AAI543
NFAI543
108
126 145
2314697 FLKM-KS40/AO16/YCS/ZFKDS
AAI543
NFAI543
108
126 148
2311344 UM-2KS40/AIO16/CS/Z/SO180
108
128 151
2901419 FLKMS-2KS40/BFI/AIO16/Z/YCS
AAI141, AAI841
NFAI141, NFAI841
151
128 154
2321907 FLKM-2KS40/PMT/YCS
AAI135, AAI835
NFAI135, NFAI835
135
77 157
2321978 FLKM-2KS40/PMT/Z/YCS
AAI135, AAI835
NFAI135, NFAI835
135
77 161
2901034 FLKM-2KS40/PMT/SI/YCS
AAI135, AAI835
NFAI135, NFAI835
93
126 168
2321936 FLKM-2KS40/PMT/SI/Z/YCS
AAI135, AAI835
NFAI135, NFAI835
93
126 171
108
128 175
108
128 179
2321871 FLKM-2KS50/AAR145/Z/YCS
AAR145
169
77 182
4U*) 8U*)
4U*) 8U*)
2903571 TC-2KS50-DI32-M-MR-CS
ADV151, ADV161
NFDV151, NFDV161
170
242 186
2902661 TC-2KS40-AIO16R-CS3000
AAI141, AAI543
NFAI141, NFAI543
170
244 188
Solutions with MINI MCR for analog input and analog output cards
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
16
2864105 MINI MCR-SL-NAM-2RNO *) Namur s witching input with s pecial cable FLK 14 to FLK 16 in com bination with the board UM-2KS50/4FLK14/YCS
32U*) 64U*)
32U*) 64U*)
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 4 of 202
05/12/2012
12 channel isolated)
Dimensions (B | T) in mm
Spring-cage connection
Centum CS 3000 R3
Knife disconnectIion
Screw connection
AAR181(PT100
Stardom
Order No.
Page
VARIOFACE termination board for digital I/O modules These boards have been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize this board: - Universal 1:1 connection - Screw / spring-cage connection to the field level - Following I/O-modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for digital I/O cards (ADV151, ADV161, ADV551, ADV561, NFDV151, NFDV161, NFDV551, NFDV561) Screw connection Spring-cage connection
UM-2KS50/UNI/CS UM-2KS50/UNI/CS/Z/SO180
2319427 2311399
1 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 5 of 202
05/12/2012
Connection scheme:
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 6 of 202
05/12/2012
VARIOFACE termination board for Digital I/O modules These boards have been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize these boards: - Transmission of 32 channels - Plus and minus connection per signal - Screw connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Following I/O modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for digital I/O cards (ADV151, ADV161, ADV551, NFDV151, NFDV161, NFDV551, NFDV561)
FLKMS-KS50/32IM/YCS
2314451
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 1A 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
P1+
P1+
P1-
P1-
P2+
P2+
P2-
P2-
X11
X1A
49 50
1 2
X10
1A 2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A 17A 18A 19A 20A 21A 22A 23A 24A 25A 26A 27A 28A 29A 30A 31A 32A
1B
2B
3B
4B
5B
6B
7B
8B
9B 10B 11B 12B 13B 14B 15B 16B 17B 18B 19B 20B 21B 22B 23B 24B 25B 26B 27B 28B 29B 30B 31B 32B
1C
2C
3C 4C
5C
6C
7B
8B
9B 10C 11C 12C 13C 14C 15C 16C 17C 18C 20C 20C 21C 22C 23C 24C 25C 26C 27C 28C 29C 30C 31C 32C
174
81
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 7 of 202
05/12/2012
Connection scheme:
17
18
19
20
21
22
23
24
25
10
26
11
27
12
28
13
29
14
30
15
31
16
32
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 8 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 9 of 202
05/12/2012
VARIOFACE termination board for Digital I/O modules These boards have been specially designed for coupling to the digital I/O modules with dedicated system cables for redundant apllications. The following features characterize these boards: - Transmission of 32 channels - Plus and minus connection per signal - Screw connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Two system connectors in parallel for redundant applications. - Following I/O modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for digital I/O cards (ADV151, ADV161, ADV551, NFDV151, NFDV161, NFDV551, NFDV561)
FLKMS-2KS50/32IM/YCS
2901896
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 1A 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation 2X Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 10 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 11 of 202
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 12 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 13 of 202
05/12/2012
VARIOFACE termination board for Digital I/O modules These boards have been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize these boards: - Transmission of 32 channels - Plus connection per signal with pluggable fuse - Screw connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Two system connectors in parallel for redundant applications. - Following I/O modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board with fuses for 32 channels (ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561) FLKM-KS50/SI/YCS 2314464 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 80mA, pluggable fuse per plus connection (5X20, 0.1A) 2A (P1+, P2+, P3+, P4+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category I, basic isolation 2 X Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 14 of 202
05/12/2012
Connection scheme:
17
18
19
20
21
22
23
24
25
10
26
11
27
12
28
13
29
14
30
15
31
16
32
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 15 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 16 of 202
05/12/2012
VARIOFACE termination board for Digital I/O modules This board has been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize this board: - Transmission of 32 channels - Plus and minus connection per signal - Screw connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Power supply monitoring - Following I/O modules can be used: ADV151, ADV161, NFDV151, NFDV161
Note: Picture shows spring-cage connection
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 32 channels (ADV151, ADV161, NFDV151, NFDV161) UM-2KS50/DI32/CS/SO180 2901013 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (F101 / F117) Max. total current (voltage supply, F150/F151) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Dimensional drawing
24 V DC 10% 100mA 1A, pluggable fuse (5X20, 1A) 2A, pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 17 of 202
R17
R18
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 18 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 19 of 202
05/12/2012
VARIOFACE termination board for Digital I/O modules This board has been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize this board: - Transmission of 32 channels - Plus and minus connection per signal - Spring-cage connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Power supply monitoring - Following I/O modules can be used: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 32 channels (ADV151, ADV161, NFDV151, NFDV161) UM-2KS50/DI32/CS/Z/SO180 2311360 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (F101 / F117) Max. total current (voltage supply, F150/F151) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Dimensional drawing
24 V DC 10% 100mA 1A, pluggable fuse (5X20, 1A) 2A, pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 20 of 202
05/12/2012
Connection scheme:
Channels1 ... 16
Field 1 X10
1C 1+ 150
Channels 17 ... 32
X1B X1A CH. Field
50
X10
17C 17+ 17-
17
17
LD01
48 48
LD17
47 47
2C
18C
2+ 23C
18
18+ 1819C
18
LD02
46 46
LD18
45 45
3+ 34C
19
19+ 1920C
19
LD03
44 44
LD19
43 43
4+ 4-
20
20+ 20-
20
LD04
42 42
LD20
41 41
5C
21C
5+ 56C
21
21+ 21-
21
LD05
40 40
LD21
39 39
22C
6+ 6-
22
22+ 22-
22
LD06
38 38
LD22
37 37
7C
23C
7+ 7-
23
23+ 23-
23
LD07
36 36
LD23
35 35
8C
24C
8+ 89C
24
24+ 2425C
24
LD08
34 34
LD24
33 33
9+ 9-
25
25+ 25-
25
LD09
32 32
LD25
31 31
10C
26C
10
10+ 1011C
10
26
26+ 2627C
26
LD10
30 30
LD26
29 29
11
11+ 11-
11
27
27+ 27-
27
LD11
28 28
LD27
27 27
12C
28C
12
12+ 12-
12
28
28+ 28-
28
LD12
26 26
LD28
25 25
13C
29C
13
1313-
13
29
29+ 29-
29
LD13
24 24
LD29
23 23
14C
30C
14
14+ 14-
14
30
30+ 30-
30
LD14
22 22
LD30
21 21
15C
31C
15
15+ 15-
15
31
31+ 31-
31
LD15
20 20
LD31
19 19
16C
32C
16
16+ 16-
16
32
32+ 32-
32
LD16
LD32
X20
5(+) 6(-) 3(+) 4(-) 1 2 Power Supply monitoring
0V
1 2
1 CBSE 2 CBSE
+24V
12 R1-16 A 14 16 18
12 14 16 18 R17-32 B
11 13 15 17
11 13 15 17
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 21 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 22 of 202
05/12/2012
VARIOFACE termination board for digital input with knife disconnection These boards have been specially designed for coupling to the digital input I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Screw connection with knife disconnection to the field level - Redundant I/O connector - LED indication per channel - Fuse per channel - Two-wire connection with board supply - Power supply detection - Following input modules can be used: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for digital Input (ADV151, ADV161, NFDV151, NFDV161) FLKM-2KS50/PMT/ADV151/YCS Component parts VF-SI/TR5/0,063AT VF-SI/TR5/2AT 2901004 2900996 8 8 2321884 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 63mA, pluggable fuse (IEC 60127-3, 0.063A) 2A (P1+, P2+), pluggable fuse (IEC 60127-3, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 23 of 202
05/12/2012
Yokogawa Yokogawa
32 DI X 32 DI
The labels 33B - 64B/33A - 64A and the additional board sticker 64DI X are enclosed in the cardboard box.
64 DI 64 DI X
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 24 of 202
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 25 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 26 of 202
05/12/2012
VARIOFACE termination board for digital input with knife disconnection These boards have been specially designed for coupling to the digital input I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Spring-cage connection with knife disconnection to the field level - Redundant I/O connector - LED indication per channel - Fuse per channel - Two-wire connection with board supply - Power supply detection - Following input modules can be used: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for digital Input (ADV151, ADV161, NFDV151, NFDV161) Component parts
FLKM-2KS50/PMT/ADV151/Z/YCS
2321923
2901004 2900996
8 8
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 63mA, pluggable fuse (IEC 60127-3, 0.063A) 2A (P1+, P2+), pluggable fuse (IEC 60127-3, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 27 of 202
05/12/2012
Yokogawa Yokogawa
32 DI X 32 DI
The labels 33B - 64B/33A - 64A and the additional board sticker 64DI X are enclosed in the cardboard box.
64 DI 64 DI X
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 28 of 202
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 29 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 30 of 202
05/12/2012
VARIOFACE termination board for digital input and digital output These boards have been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize these boards: - Redundant I/O connector - Blown fuse indication per channel via red LED - Two-wire connection with board supply - Power supply detection with alarm contact and green LED - Spring terminal connection to the field level - Following I/O modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for digital I/O (ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561) Right side version Left side version
FLKM-2KS50/BFI/SPT/CS FLKM-2KS50/BFI/SPT/CS/C-L
2321813 2321842
1 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 20% 100mA, pluggable fuse 5X20, 0.1 AT 4AT (5+, 3+), pluggable fuse 5X20, 4AT 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 31 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 32 of 202
05/12/2012
Connection scheme:
Channels 1 ... 16
Field X10
1A 1B
Channels 17 ... 32
X1B
50 50 17A
X1A
Ch.
Field X10
X1B X1A
49 49
Ch.
1
48
17B
17
47
2A 2B
48
18A
47
2
46
18B
18
45
3A 3B
46
19A
45
3
44
19B
19
43
4A 4B
44
20A
43
4
42
20B
20
41
5A 5B
42
21A
41
5
40 40
21B
21
39
6A 6B
22A
39
6
38
22B
22
37
7A 7B
38
23A
37
7
36
23B
23
35
8A 8B
36
24A
35
8
34
24B
24
33
9A 9B
34
25A
33
9
32
25B
25
31
10A 10B
32
26A
31
10
30
26B
26
29
11A 11B
30
27A
29
11
28
27B
27
27
12A 12B
28
28A
27
12
26
28B
28
25
13A 13B
26
29A
25
13
24
29B
29
23
14A 14B
24
30A
23
14
22
30B
30
21
15A 15B
22
31A
21
15
20
31B
31
19
16A 16B
20
32A
19
16
32B
32
X20
5 (+) 6 (-) 3 (+) 4 (-) 1 2
F100
7 9 1 2 12
7 9 1 2 12 14 16 18
8 10
8 10
F101
CBSE
11 11
14 16 18
COM 1-16
13 15 17
13 15 17
COM 17-32
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 33 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 34 of 202
05/12/2012
VARIOFACE termination board for digital input and digital output These boards have been specially designed for coupling to the digital I/O modules with dedicated system cables. The following features characterize these boards: - Redundant I/O connector - Blown fuse indication per channel via red LED - Two-wire connection with board supply - Power supply detection with alarm contact and green LED - Screw terminal connection to the field level - Following I/O modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Note: Picture shows spring-cage connection
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for digital I/O (ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561) FLKM-2KS50/BFI/MKDS/CS 2900162
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 20% 100mA, pluggable fuse 5X20, 0.1 AT 4AT (5+, 3+), pluggable fuse 5X20, 4AT 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 35 of 202
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 36 of 202
05/12/2012
Connection scheme:
Channels 1 ... 16
Field X10
1A 1B
Channels 17 ... 32
X1B
50 50 17A
X1A
Ch.
Field X10
X1B X1A
49 49
Ch.
1
48
17B
17
47
2A 2B
48
18A
47
2
46
18B
18
45
3A 3B
46
19A
45
3
44
19B
19
43
4A 4B
44
20A
43
4
42
20B
20
41
5A 5B
42
21A
41
5
40 40
21B
21
39
6A 6B
22A
39
6
38
22B
22
37
7A 7B
38
23A
37
7
36
23B
23
35
8A 8B
36
24A
35
8
34
24B
24
33
9A 9B
34
25A
33
9
32
25B
25
31
10A 10B
32
26A
31
10
30
26B
26
29
11A 11B
30
27A
29
11
28
27B
27
27
12A 12B
28
28A
27
12
26
28B
28
25
13A 13B
26
29A
25
13
24
29B
29
23
14A 14B
24
30A
23
14
22
30B
30
21
15A 15B
22
31A
21
15
20
31B
31
19
16A 16B
20
32A
19
16
32B
32
X20
5 (+) 6 (-) 3 (+) 4 (-) 1 2
F100
7 9 1 2 12
7 9 1 2 12 14 16 18
8 10
8 10
F101
CBSE
11 11
14 16 18
COM 1-16
13 15 17
13 15 17
COM 17-32
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 37 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 38 of 202
05/12/2012
VARIOFACE V8 adapter for 6.2 mm PLC Relay terminals (1 PDT) The PLC-V8 adapter is simply inserted in the jumper slots of eight 6.2 mm PLC INTERFACE modules mounted side by side. No additional tools are required. This results in an 8-channel relay or optocoupler module with a width of less than 50 mm. The insertion of electromechanical or solid-state relays can be freely selected for each channel.
Description
Part Description
Order No.
Pcs. Pkt.
PLC-V8/FLK14/IN
2296553
Technical Data Operating voltage Max. continuous current : Test voltage Ambient temperature range Installation position Standards/regulations Dimensions (H x W x D) Connection to I/O Connection data solid / stranded / AWG Tightening torque 24 V DC 10% 1A 3A 0.5 kV, 50 Hz, 1 min. 20 C to + 50 C any IEC 60 644 (1980) /IEC 60 644 A (1981) /DIN VDE 0110 (1.89) housing width: 49,6 mm in combination with PLC Relay: 100 x 49,6 x 94 mm ribbon cable connector, 14pins, IEC603-1 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 39 of 202
05/12/2012
Universal PLC series with PDT relay equipped with pluggable power contact relay 1 PDT (21), 6.2 mm The PLC-R...21 is a relay series, that can be used universally and consists of basic terminal blocks and pluggable miniature relays with PDT contact. Functional plug-in bridges Screw connection and spring-cage connection system naturally with the same shape Input or output interface. In the standard version, the PLC relays are supplied equipped with relay. An input circuit consisting of a status display, free-wheeling and reverse polarity protection function is integrated in the module. PLC-R... is equipped with a robust miniature relay. Its main features include: IP67 protection Environmentally friendly, cadmium-free contact material The relay is securely fastened using an engagement lever. Should it become worn, it can be disengaged and without disconnecting the wiring can be replaced quickly and economically.
Description
Part Description
Order No.
Pcs. Pkt.
PLC interface with screw connection, consisting of basic terminal block PLC-BSC/21 and pluggable miniature relay, for mounting on PLC interface with spring-cage connection, consisting of basic terminal block PLC-BSC/21 and pluggable miniature relay, for mounting on
24 V DC 24 V AC/DC 120 V AC/110 V DC 230 V AC/220 V DC 24 V DC 24 V AC/DC 120 V AC/110 V DC 230 V AC/220 V DC
PLC-RSC- 24DC/21AU PLC-RSC- 24UC/21AU PLC-RSC-120UC/21AU PLC-RSC-230UC/21AU PLC-RSP- 24DC/21AU PLC-RSP- 24UC/21AU PLC-RSP-120UC/21AU PLC-RSP-230UC/21AU
10 10 10 10 10 10 10 10
Technical Data Input data Nominal input voltage UN Typ. input current at UN Typ. response time at UN Typ. release time at UN Input protection
Connection data screw: solid / stranded / AWG Connection data spring-cage: solid / stranded / AWG Output data Contact type Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Max. power rating, ohmic load
120 V AC/ 230 V AC/ 110 V DC 220 V DC 9 mA 11/8.5 mA 3.5/3 mA 3.2/3 mA 5 ms 6 ms 6 ms 7 ms 8 ms 15 ms 15 ms 15 ms Operating indicator, polarity protection diode, free wheeling diode Operating indicator, bridge rectifier 0,14 2,5 / 0,14 2,5 / 26 14 0,2 2,5 / 0,2 2,5 / 24 - 14
24 V DC
24 V AC/DC
Single contact, 1 PDT Ag alloy, hard gold-plated 30 V AC/ 36V DC 100 mV AC/DC 50 mA 50 mA 1 mA 1,2 W -
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 40 of 202
05/12/2012
Universal PLC series with PDT relay equipped with pluggable power contact relay 1 PDT (21), 6.2 mm
General data Test voltage I/O Ambient temperature range Rated operating mode Inflammability class Mechanical service life Standards/regulations 4 kV, 50 Hz, 1 min. -20 C to +60 C 100% operating factor V0 in acc. with UL 94 7 2 x 10 cycles IEC 60 664/IEC 60 664 A/DIN VDE 0110; contamination class 3, surge voltage category III, DIN EN 50 178/VDE 0160 (in relev. parts, IEC 60 255/DIN VDE 0435 (in relev. parts), DIN EN 50 178 (VDE 0160): 1998-04, increased insulation I/O) 6,2 x 94 x 80 mm As desired, in rows with zero spacing
Connection scheme:
1)
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 41 of 202
05/12/2012
VARIOFACE relay modules for digital input These modules have been specially designed for coupling to the digital input modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays - Depending on the jumper positions each channel can be set as power supply from the field or power supply from the board - LED status display and pluggable fuse for each signal path and each supply voltage - Spring-cage connection to the field level - Redundant system power supply - Following input modules can be used: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay input module for 32 channels (ADV151, ADV161, NFDV151, NFDV161) with 32 relays, plugged, for 24 V DC (incl. Relays) Component parts
UM-KS50/32-MR/21/ADV151/SO207
2311111
VF-SI/TR5/1AT VF-SI/TR5/2AT Technical Data Coil side Operating voltage Typ. input current per channel Pluggable fuse per channel Max. total current (voltage supply) Input circuit
2901005 2900996
8 8
24 V DC 10% 7 mA 1, pluggable fuse (IEC 60127-3, 1A) 2A (V1+, V2+) pluggable fuse (IEC 60127-3, 2A) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply) General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
1 N/O contact 24V AC/DC 100 mA 1A (P1+, P2+), pluggable fuse (IEC 60127-3, 1A)
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 1 Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 42 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 43 of 202
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 44 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 45 of 202
05/12/2012
VARIOFACE relay modules for digital input These modules have been specially designed for coupling to the digital input modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays - Depending on the jumper positions each channel can be set as power supply from the field or power supply from the board - LED status display and pluggable fuse for each signal path and each supply voltage - Screw connection to the field level - Redundant system power supply - Following input modules can be used: ADV151, ADV161, NFDV151, NFDV161
Note: Picture shows spring-cage connection
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay input module for 32 channels (ADV151, ADV161, NFDV151, NFDV161) with 32 relays, plugged, for 24 V DC (incl. Relays) Component parts
UM-KS50/32MR/1/ADV151/SC/SO207
2900898
VF-SI/TR5/1AT VF-SI/TR5/2AT Technical Data Coil side Operating voltage Typ. input current per channel Pluggable fuse per channel Max. total current (voltage supply) Input circuit
2901005 2900996
8 8
24 V DC 10% 9 mA 1, pluggable fuse (IEC 60127-3, 1A) 2A (V1+, V2+) pluggable fuse (IEC 60127-3, 2A) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply)
1 N/O contact 24V AC/DC 1A 2A (P1+, P2+), pluggable fuse (IEC 60127-3, 1A)
General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 1 Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 46 of 202
05/12/2012
Dimensional drawing:
P1+ P1+
128
V1+ V1- 1A
2A
3A
4A
5A
6A
7A
8A
17A 18A 19A 20A 21A 22A 23A 24A 25A 26A 27A 28A 29A 30A 31A 32A V2+ V2-
V1+ V1- 1B
2B
3B
4B
5B
6B
7B
8B
17B 18B 19B 20B 21B 22B 23B 24B 25B 26B 27B 28B 29B 30B 31B 32B V2+ V2-
232,5
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 47 of 202
05/12/2012
Connection Scheme:
Channels1 ... 16
Jumper position per channel power field Jumper position per channel power board Jumper position per channel power field
Channels 17 ... 32
Jumper position per channel power board
X 10
1A 1A 1B 1B 2A 2B 2B
X 10
X1A
Ch . IN 1
X10
17A
X10
17A 17B
X1 A
Ch. IN 17
50
49
2A
18A
48 3A
IN 2
47
IN 18
3A
3B 46 4A
IN 3
19A
19B
IN 19
45
3B
4A
4B 44 5A
IN 4
20B
20B 43 21A
4B
IN 20
5A
5B 42 6A
21A
IN 5
21B
21B 41 22A
5B
IN 21
6A
6B 40 7A
22A
IN 6
22B
22B 39 23A
6B
IN 22
7A
7B
IN 7
38
23A
23B 37 24A
IN 23
7B 8A 8A 8B
23B
24A
36
IN 8
24B -V2 -V2
24B 35
IN 24
2A
2A
25A 25B
IN 9
34 25B
IN 25
33
10A
26A
26A 26B
32 11A
IN 10
26B
31
IN 26
11A
27A
11B
IN 11
30
27A
27B 29 28A
IN 27
27B
28A
28
IN 12
28B
28B
27 29A
IN 28
29A
26
IN 13
29B
29B
25 30A
IN 29
30A
24
IN 14
30B
30B
23 31A
IN 30
IN 15
22
31A
31B
IN 31
21
16B
20
IN 16
32B
32B
19
IN 32
X20
P1+ P1+ P2+ P2+ P1P1P2P21 2 12 14 16 18
CBSE
11
COM 1-16
13 15 17
COM 17-32
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 48 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 49 of 202
05/12/2012
VARIOFACE relay modules for digital input These boards have been specially designed for coupling to the digital input modules with dedicated system cables. The following features characterize these boards: - Pluggable relays - Depending on the jumper positions two input types are possible: - Connection of a simple switch contact - Positive and negative input potential - LED status display and pluggable fuse for each - Signal path and each supply voltage - Screw connection to the field level - Redundant system power supply Following input modules can be used: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay input module for 32 channels (ADV151, ADV161, NFDV151, NFDV161) with 32 relays, plugged, for 24 V DC (incl. Relays) Technical Data Coil side Operating voltage Typ. input current per channel Pluggable fuse per channel Max. total current (voltage supply) Input circuit
UM-2KS50/32-MR/21/ADV151/SO179
2310222
24 V DC 10% 18 mA 80mA, pluggable fuse (5X20, 80mAT) 2A (V1+, V2+, V3+, V4+) pluggable fuse (5X20, 2AF) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply) General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Dimensional drawing:
1 N/O contact 24V AC/DC 1A , pluggable fuse (5X20, 1A) 1A (P1+, P2+, P3+, P4+), pluggable fuse (5X20, 1AT)
2 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 50 of 202
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 51 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 52 of 202
05/12/2012
VARIOFACE NAMUR modules for digital input These modules have been specially designed for coupling to the digital input modules with dedicated system cables. The module converts the changing resistance of NAMUR sensors to readable digital signals. The following features characterize these boards: - Regulated power supply for the NAMUR proximity switch - Defined recognition and evaluation of the analog sensor signals - Monitoring of the sensor lines for short circuits and wire breaks; a fault is signalized by a red LED per channel and optional via one relay - Status display per signal via green LED - Spring-cage connection to the field level - Following input modules can be used: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE NAMUR module for 32 channels with Spring-cage connection (ADV151, ADV161, NFDV151, NFDV161) Component parts
UMK-32NAM/I/MYCS
2968506
VF-SI/TR5/0,4AT Technical Data Supply Supply voltage Current consumption Protective circuit Control circuit Non-load voltage Switching points - In unattenuated state - In unattenuated state - For short circuit - For wire break Internal resistance Short circuit current Signal output Max. switching current Max. switching voltage Status display Error detection (line break, short circuit)
2900997
8.2 V DC 10% In acc. with DIN 19234 2.1 mA 1.2 mA 6.3 10mA 0 0.35 mA Approx. 1 kOHM 10 mA
10 mA 28.4 V DC Green LED Red LED Optional via one relay with 1PDT contact
General data Ambient temperature range Transmission frequency (INPUT/OUTPUT) Input pulse length Input pause length Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
20 C to + 50 C 350 Hz 0.5 ms 0.5 ms any DIN EN 50178, contamination class 2, surge voltage category I, basic isolation 2 X Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,14 2,5 mm / 0,14 1,5mm / 26 14 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 53 of 202
05/12/2012
128
49
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
50
Page 54 of 202
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 55 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 56 of 202
05/12/2012
VARIOFACE V8 adapter for 6.2 mm PLC Relay terminals (1 PDT) The PLC-V8 adapter is simply inserted in the jumper slots of eight 6.2 mm PLC INTERFACE modules mounted side by side. No additional tools are required. This results in an 8-channel relay or optocoupler module with a width of less than 50 mm. The insertion of electromechanical or solid-state relays can be freely selected for each channel.
Description
Part Description
Order No.
Pcs. Pkt.
PLC-V8/FLK14/OUT/M
2304102
Technical Data Operating voltage Max. continuous current : Test voltage Ambient temperature range Installation position Standards/regulations Dimensions (H x W x D) Connection to I/O Connection data solid / stranded / AWG Tightening torque 24 V DC 10% 1A 3A 0.5 kV, 50 Hz, 1 min. 20 C to + 50 C any IEC 60 644 (1980) /IEC 60 644 A (1981) /DIN VDE 0110 (1.89) housing width: 49,6 mm in combination with PLC Relay: 100 x 49,6 x 94 mm ribbon cable connector, 14pins, IEC603-1 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 57 of 202
05/12/2012
Universal PLC series with PDT relay equipped with pluggable power contact relay 1 PDT (21), 6.2 mm The PLC-R...21 is a relay series, that can be used universally and consists of basic terminal blocks and pluggable miniature relays with PDT contact. Functional plug-in bridges Screw connection and spring-cage connection system naturally with the same shape Input or output interface. In the standard version, the PLC relays are supplied equipped with relay. An input circuit consisting of a status display, free-wheeling and reverse polarity protection function is integrated in the module. PLC-R... is equipped with a robust miniature relay. Its main features include: IP67 protection Environmentally friendly, cadmium-free contact material The relay is securely fastened using an engagement lever. Should it become worn, it can be disengaged and without disconnecting the wiring can be replaced quickly and economically.
solid stranded [mm] 0,14-2.5 Description 0,14-2,5 AWG 26-14 tightening torque [Nm] [lb in] 0,5-0,6 4,4-5,3 Part Description
PLC-R21
Order No.
Pcs. Pkt.
PLC interface with screw connection, consisting of basic terminal block PLC-BSC/21 and pluggable miniature relay, for mounting on PLC interface with spring-cage connection, consisting of basic terminal block PLC-BSC/21 and pluggable miniature relay, for mounting on
24 V DC 24 V AC/DC 120 V AC/110 V DC 230 V AC/220 V DC 24 V DC 24 V AC/DC 120 V AC/110 V DC 230 V AC/220 V DC
PLC-RSC- 24DC/21 PLC-RSC- 24UC/21 PLC-RSC-120UC/21 PLC-RSC-230UC/21 PLC-RSP- 24DC/21 PLC-RSP- 24UC/21 PLC-RSP-120UC/21 PLC-RSP-230UC/21
10 10 10 10 10 10 10 10
Technical Data Input data Nominal input voltage UN Typ. input current at UN Typ. response time at UN Typ. release time at UN Input protection
Connection data screw: solid / stranded / AWG Connection data spring-cage: solid / stranded / AWG Output data Contact type Contact material Max. switching voltage Min. switching voltage Limiting continuous current Max. inrush current Min. switching current Max. power rating, ohmic load
120 V AC/ 230 V AC/ 110 V DC 220 V DC 9 mA 11/8.5 mA 3.5/3 mA 3.2/3 mA 5 ms 6 ms 6 ms 7 ms 8 ms 15 ms 15 ms 15 ms Operating indicator, polarity protection diode, free wheeling diode Operating indicator, bridge rectifier 0,14 2,5 / 0,14 2,5 / 26 14 0,2 2,5 / 0,2 2,5 / 24 - 14
24 V DC
24 V AC/DC
Single contact, 1 PDT AgSnO 250 V AC/DC 12 V AC/DC 6A Available on request 10 mA 140 W 23 W 40 W 1500 VA 120 mA
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 58 of 202
05/12/2012
Universal PLC series with PDT relay equipped with pluggable power contact relay 1 PDT (21), 6.2 mm
General data Test voltage I/O Ambient temperature range Rated operating mode Inflammability class Mechanical service life Standards/regulations 4 kV, 50 Hz, 1 min. -20 C to +60 C (120, 230 V types to +55 C) 100% operating factor V0 in acc. with UL 94 7 2 x 10 cycles IEC 60 664/IEC 60 664 A/DIN VDE 0110; contamination class 3, surge voltage catergory III, DIN EN 50 178/VDE 0160 (in relev. parts, IEC 60 255/DIN VDE 0435 (in relev. parts), DIN EN 50 178 (VDE 0160): 1998-04, increased insulation I/O) 80 x 6.2 x 94 mm As desired, in rows with zero spacing
Connection scheme:
1)
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 59 of 202
05/12/2012
VARIOFACE relay modules (1 N/O) for Digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable miniature relays, each with a N/O contact - Universal applications from 1mA to 3A continuous current through 2-layer double contact with hard gold plating - Slim construction widths of only 202mm - screw connection to the field level - LED status display for each signal path and supply voltage - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output module for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 miniature relays, plugged, for 24 V DC (incl. Relays) Technical Data Coil side Operating voltage Typ. input current Input circuit
UMK-32RM/MR-G24/21/YCS
2969055
24 V DC 10% 6.5 mA damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current General data Max. total current (voltage supply) Rated surge voltage Ambient temperature range Installation position Standards/regulations Dimensions (H x W x D) Connection to I/O Connection data solid / stranded / AWG Tightening torque
2A (P1+, P2+), pluggable fuse (5X20, 2A) 2 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 90 x 202 x 58 mm Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,14 1,5 mm / 0,14 1,5mm / 26 14 0,5 0,6 Nm
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
90
PMB
PMB
Page 60 of 202
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 61 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 62 of 202
05/12/2012
VARIOFACE relay modules for digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays, each with a N/O contact. - Floating relay contacts or voltage output connection per relay depending on the jumper settings - LED status display and pluggable fuse for each signal path and each supply voltage - Spring-cage connection to the field level - Redundant system power supply - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output module for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays, plugged, for 24 V DC (incl. Relays) Component parts
UM-KS50/32-MR/21/ADV551/SO207
2311108
VF-SI/TR5/1AT VF-SI/TR5/2AT Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
2901005 2900996
8 8
24 V DC 10% 7 mA 1A (P1+, P2), pluggable fuse (IEC 60127-3, 1A)) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply) (max. power rating of the contact (ohmic load) General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
1 N/O 230V AC 2 A, pluggable fuse (IEC 60127-3, 2A)) 8 A (V1+, V2+), pluggable fuse (IEC 60127-3, 8A) 140 W 24 V DC; 23 W 110 V DC
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 63 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 64 of 202
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 65 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 66 of 202
05/12/2012
VARIOFACE relay modules for digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays, each with a N/O contact. - Floating relay contacts or voltage output connection per relay depending on the jumper settings - LED status display and pluggable fuse for each signal path and each supply voltage - Screw connection to the field level - Redundant system power supply - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output module for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays, plugged, for 24 V DC (incl. Relays) Component parts
UM-KS50/32MR/1/ADV551/SC/SO207
2900899
VF-SI/TR5/1AT VF-SI/TR5/8AT VF-SI/TR5/2AT Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
8 8 8
24 V DC 10% 9 mA 1A (P1+, P2), pluggable fuse (IEC 60127-3, 1A)) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply) (max. power rating of the contact (ohmic load) General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
1 N/O 230V AC 2 A, pluggable fuse (IEC 60127-3, 2A)) 8 A (V1+, V2+), pluggable fuse (IEC 60127-3, 8A) 140 W 24 V DC; 23 W 110 V DC
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 67 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
127,5 128
Page 68 of 202
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 69 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 70 of 202
05/12/2012
VARIOFACE relay modules (1 N/O) for digital output This board has been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable miniature relays, each with a N/O contact - Universal applications from 1mA to 4A - Slim construction widths of only 240 mm - Screw connection to the field level - LED status display for each signal path and supply voltage - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output module for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 miniature relays, plugged, for 24 V DC (incl. Relays) Technical Data Coil side Operating voltage Typ. input current Input circuit
UM-2KS50/DO32REL/CS/SO180
2311373
24 V DC 10% 15,6 mA 20% damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current General data Max. total current (voltage supply) Rated surge voltage (coil side) Ambient temperature range Installation position Standards/regulations Dimensions (H x W x D) Connection to I/O Connection data solid / stranded / AWG Tightening torque Dimensional drawing:
2A (P1+, P2+), pluggable fuse (IEC 127-2, 5X20, 2A) 0,5 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation 126 x 240 x 70 mm Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,14 1,5 mm / 0,14 1,5mm / 26 14 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 71 of 202
05/12/2012
Connection Scheme:
Channels1 ... 16
Field
+
Channels 17 ... 32
X1B X1A CH. Field
+
X10
01A K01 b
X10
17A K17 b
1
+ 01B 02A K02
OUT-1 a LD01 50 50
17
+ 17B 18A K18
49
49
b OUT-2 a LD02
b OUT-18 a LD18 47 47
2
+ 02B 03A K03
18
+ 18B 19A K19
48
48
b OUT-3 a LD03
b OUT-19 a LD19 45 45
3
+ 03B 04A K04
19
+ 19B 20A K20
46
46
b OUT-4 a LD04
b OUT-20 a LD20 43 43
4
+ 04B 05A K05
20
+ 20B 21A K21
44
44
b OUT-5 a LD05
b OUT-21 a LD21 41
5
+ 05B 06A K06
21
+ 21B 22A K22
42
42
41
b OUT-6 a LD06
b OUT-22 a LD22 39 39
6
+ 06B 07A K07
22
+ 22B 23A K23
40
40
b OUT-7 a LD07
b OUT-23 a LD23 37 37
7
+ 07B 08A K08
23
+ 23B 24A K24
38
38
b OUT-8 a LD08
b OUT-24 a LD24 35 35
8
+ 08B 09A K09
24
+ 24B 25A K25
36
36
b OUT-9 a LD09
b OUT-25 a LD25 33 33
9
+ 09B 10A K10
25
+ 25B 26A K26
34
34
b OUT-10 a LD10
b OUT-26 a LD26 31 31
10
+ 10B 11A K11
26
+ 26B 27A K27
32
32
b OUT-11 a LD11
b OUT-27 a LD27 29 29
11
+ 11B 12A K12
27
+ 27B 28A K28
30
30
b OUT-12 a LD12
b OUT-28 a LD28 27 27
12
+ 12B 13A K13
28
+ 28B 29A K29
28
28
b OUT-13 a LD13
b OUT-29 a LD29 25 25
13
+ 13B 14A K14
29
+ 29B 30A K30
26
26
b OUT-14 a LD14
b OUT-30 a LD30 23 23
14
+ 14B 15A K15
30
+ 30B 31A K32
24
24
b OUT-15 a LD15
b OUT-31 a LD31 21 21
15
+ 15B 16A K16
31
+ 31B 32A K32
22
22
b OUT-16 a LD16
b OUT-32 a LD32 19 19
16
16B
32
32B
20
20
7, 9
7, 9
8, 10 8, 10
X20
5(+) 6(-) 3(+) 4(-) 1 2 Power Supply monitoring
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 72 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 73 of 202
05/12/2012
VARIOFACE relay modules for Digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays, each with a N/O or N/C contact depending on the jumper setting - Floating relay contacts or voltage output connection per relay depending on the jumper settings - LED status display and pluggable fuse for each signal path and each supply voltage - Screw connection to the field level - Redundant system power supply - Two system connectors in parallel for redundant applications. - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output module for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays, plugged, for 24 V DC (incl. Relays) Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
UM-2KS50/32- MR/21/ADV551/SO179
2310235
24 V DC 10% 18 mA 1A (P1+, P2+, P3+,P4+), pluggable fuse (5X20, 1A) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply)
1 N/O, 1 N/C contact (depending on jumper setting) 24V AC/DC 1 A, pluggable fuse (5X20, 1A) 8A (V1+, V2+,V3+,V4+), pluggable fuse (5X20, 8A)
General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
2 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 74 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 75 of 202
05/12/2012
Connection Scheme :
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 76 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 77 of 202
05/12/2012
VARIOFACE relay modules for digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays, - Depending on the jumper settings: Voltage output connection in 4 groups of 8 relays or potential free contacts - LED status display and pluggable fuse for each signal path and each supply voltage - Redundant system power supply - Two system connectors in parallel for redundant applications. - Screw connection with knife disconnection to the field level - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output modules for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays, (incl. Relays) Component parts
UM-2KS50RM/32MR/SI/1/ADV551/MT
2968564
8 8 8
Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
24 V DC 10% 7 mA 1A (P1+, P2+), pluggable fuse (IEC 60127-3, 1A) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply)
1 N/O contact 250 V AC/DC 1,2 A, pluggable fuse (IEC 60127-3, 4A) 8A (V1+, V2+,V3+,V4+), pluggable fuse (IEC 60127-3, 8A)
General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 78 of 202
05/12/2012
Dimensional drawing:
The additional labels +1X - 33B - 64B/33A - 64A and the additional board sticker 64DI X are enclosed in the cardboard box.
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 79 of 202
05/12/2012
Connection Scheme:
Channels1 ... 16
Jumper position per channel Jumper position per channel Jumper position per channel
Channels 17 ... 32
Jumper position per channel
X10
1A 1B 1A 1B
X10
X1B X1A
Ch. OUT 1
X10
17A 17B
X10
17A 17B
X1 B X1A
Ch. OUT 17
50 50
49 49
2A 2B
2A 2B 48 48
18A
18A 18B 47 47
OUT 2 OUT 3
18B
OUT 18 OUT 19
3A 3B
3A 3B 46 46
19A 19B
19A 19B 45 45
4A 4B
4A 4B 44 44
20A
20A 20B 43 43
OUT 4
20B
OUT 20
5A 5B
5A 5B 42 42
21A
21A 21B 41 41
OUT 5
21B
OUT 21
6A 6B
6A 6B 6C 40 40
22A
22A 22B 39 39
OUT 6 OUT 7
22B
OUT 22 OUT 23
7A 7B
7A 7B 7C
23A 23B
23A 23B 37 37
38 38
8A 8B
8A 8B 36 36
24A
24A 24B 35 35
OUT 8
24B
OUT 24
V1+ V1+ V1V19A 9B 9A 9B 34 34 10A 10B 10A 10B 32 32 11A 11B 11A 11B 30 30
OUT 9
25B
OUT 25
26A
26A 26B
OUT 10
26B
31
31
OUT 26
27A
27A 27B 29 29
OUT 11
27B
OUT 27
12A 12B
12A 12B
28A
28A 28B
28
OUT 12
28
28B
27
27
OUT 28
13A 13B
13A 13B
29A
29A 29B
26
OUT 13
26
29B
25
25
OUT 29
14A 14B
14A 14B
30A
30A 30B
24
OUT 14
24
30B
23
23
OUT 30
15A 15B
15A 15B
31A
31A 31B
22
OUT 15
22
31B
21
21
OUT 31
16A 16B
16A 16B
32A
32A 32B
20
OUT 16
20
32B
19
19
OUT 32
X20
P1+ 1A P2+
13
X20
14 J1 2 1 1
7,8,9,10
24V DC
7,8,9,10
2 1 2
11,12, 13...18
2 1 CBSE
P1J2 P2-
COM
11,12, 13...18
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 80 of 202
05/12/2012
Application diagram:
UM-2KS50RM/32MR/SI/1/ADV551/MT 2968564
13
X 20
13 14 F100 14
Alarm
+24 V DC
P1+
+24 V DC F101
P1-
PW 1
0V +24 V DC
P2+
P2-
0V
PW 2
13 14
X1A / X1B
1 2 CBSE CBSE
8A
+24 V DC
7...10 11...18
+ 24VDC COM
X 10
1A A 1B B
Board Supply
4A
50
50
OUT1
A 1A 1B B 4A
X1B
Phoenix Contact FLK 50-PA-EZ-DR-KS-...-YUC or FLK-MIL-50/EZ-DR/KS/.../YCS 19 OUT32
V4V4V4+ V4+
8A
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 81 of 202
05/12/2012
VARIOFACE relay modules for digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays, - Depending on the jumper settings : Voltage output connection in 4 groups of 8 relays or potential free contacts - LED status display and pluggable fuse for each signal path and each supply voltage - Redundant system power supply - Two system connectors in parallel for redundant applications. - Spring-cage connection with knife disconnection to the field level - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output modules for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays, (incl. Relays) Component parts
UM-2KS50RM/32MR/SI/1/ADV551/Z/MT
2968551
VF-SI/TR5/8AT VF-SI/TR5/1AT VF-SI/TR5/4AT Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
8 8 8
24 V DC 10% 7 mA 1A (P1+, P2+), pluggable fuse (IEC 60127-3, 1A) damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current Max. total current (voltage supply) General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O
1 N/O contact 250 V AC/DC 1,2 A, pluggable fuse (IEC 60127-3, 1A) 8A (V1+, V2+,V3+,V4+), pluggable fuse (IEC 60127-3, 8A)
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 82 of 202
05/12/2012
Dimensional drawing:
The additional labels +1X . 33B - 64B/33A - 64A and the additional board sticker 64DI X are enclosed in the cardboard box.
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 83 of 202
05/12/2012
Connection Scheme:
Channels1 ... 16
Jumper position per channel Jumper position per channel Jumper position per channel
Channels 17 ... 32
Jumper position per channel
X10
1A 1B 1A 1B
X10
X1B X1A
Ch. OUT 1
X10
17A 17B
X10
17A 17B
X1 B X1A
Ch. OUT 17
50 50
49 49
2A 2B
2A 2B 48 48
18A
18A 18B 47 47
OUT 2 OUT 3
18B
OUT 18 OUT 19
3A 3B
3A 3B 46 46
19A 19B
19A 19B 45 45
4A 4B
4A 4B 44 44
20A
20A 20B 43 43
OUT 4
20B
OUT 20
5A 5B
5A 5B 42 42
21A
21A 21B 41 41
OUT 5
21B
OUT 21
6A 6B
6A 6B 6C 40 40
22A
OUT 6 OUT 7
OUT 22 OUT 23
7A 7B
7A 7B 7C
38 38
8A 8B
8A 8B 36 36
24A
24A 24B 35 35
OUT 8
24B
OUT 24
V1+ V1+ V1V19A 9B 9A 9B 34 34 10A 10B 10A 10B 32 32 11A 11B 11A 11B 30 30
OUT 9
25B
OUT 25
26A
26A 26B
OUT 10
26B
31
31
OUT 26
27A
27A 27B 29 29
OUT 11
27B
OUT 27
12A 12B
12A 12B
28A
28A 28B
28
OUT 12
28
28B
27
27
OUT 28
13A 13B
13A 13B
29A
29A 29B
26
OUT 13
26
29B
25
25
OUT 29
14A 14B
14A 14B
30A
30A 30B
24
OUT 14
24
30B
23
23
OUT 30
15A 15B
15A 15B
31A
31A 31B
22
OUT 15
22
31B
21
21
OUT 31
16A 16B
16A 16B
32A
32A 32B
20
OUT 16
20
32B
19
19
OUT 32
X20
P1+ 1A P2+
13
X20
14 J1 2 1 1
7,8,9,10
24V DC
7,8,9,10
2 1 2
11,12, 13...18
2 1 CBSE
P1J2 P2-
COM
11,12, 13...18
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 84 of 202
05/12/2012
Application diagram:
UM-2KS50RM/32MR/SI/1/ADV551/Z/MT 2968551
13
X 20
13 14 F100 14
Alarm
+24 V DC
P1+
+24 V DC F101
P1-
PW 1
0V +24 V DC
P2+
P2-
0V
PW 2
13 14
X1A / X1B
1 2 CBSE CBSE
8A
+24 V DC
7...10 11...18
+ 24VDC COM
X 10
1A A 1B B
Board Supply
4A
50
50
OUT1
A 1A 1B B 4A
X1B
Phoenix Contact FLK 50-PA-EZ-DR-KS-...-YUC or FLK-MIL-50/EZ-DR/KS/.../YCS 19 OUT32
V4V4V4+ V4+
8A
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 85 of 202
05/12/2012
VARIOFACE relay modules for digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays - Redundant system power supply with monitoring - Two system connectors in parallel for redundant applications - Spring terminal connection to the field level - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output module for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays(incl. Relays) Right side version Left side version Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
UM-2KS50/32RM/MR/21/SPT/CS UM-2KS50/32RM/MR/21/SPT/CS/C-L
2968519 2968535
1 1
24 V DC 10% 9 mA 1A (5+, 3+), pluggable fuse 5X20, 1 AT damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current
General data Ambient temperature range Installation position Standards/regulations Rated voltage Rated surge voltage / insulation Connection to I/O
20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III 250 V 4kV / basic isolation (safe isolation, increased insulation and 6kV between input circuit and 1 PDT contacts) 2 X Yokogawa AKB331 connector, 50pins Usable system cables: Yokogawa AKB331 PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 86 of 202
05/12/2012
Dimensional drawing
128 126 128 126
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 87 of 202
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 88 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 89 of 202
05/12/2012
VARIOFACE relay modules for digital output These modules have been specially designed for coupling to the digital output modules with dedicated system cables. The following features characterize these relay boards: - Pluggable relays - Redundant system power supply with monitoring - Two system connectors in parallel for redundant applications - Screw connection to the field level - Following output modules can be used: ADV551, ADV561, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay output modules for 32 channels (ADV551, ADV561, NFDV551, NFDV561) with 32 relays, (incl. Relays)
UM-2KS50/32RM/MR/21/MKDS/CS
2900163
Technical Data Coil side Operating voltage Typ. input current per channel Max. total current (voltage supply) Input circuit
24 V DC 10% 9 mA 1A (5+, 3+), pluggable fuse 5 X 20, 1AT damping diode and polarity protection diode operating voltage display via green LED status display/channel via yellow LED
Contact side Contact type Max. switching voltage Max. continuous current General data Rated surge voltage Ambient temperature range Installation position Standards/regulations Connection to I/O
4 kV 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 90 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 91 of 202
05/12/2012
Connection Scheme:
OUT 16
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 92 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 93 of 202
05/12/2012
VARIOFACE board for digital input/output These boards have been specially designed for coupling PLC RELAY to the digital I/O modules with dedicated system cables. The following features characterize these boards: - Redundant system power supply - 4 FLK 14 connectors for connecting to PLC-V8 adapters - Following I/O modules can be used: ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561
Description
Part Description
Order No.
Pcs. Pkt. 1
VARIOFACE digital output / input module for 32 channels (ADV151, ADV161, ADV551, ADV561 NFDV151, NFDV161, NFDV551, NFDV561) Technical Data
UM-2KS50/4FLK14/YCS
2311166
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to PLC-RELAY Connection data solid / stranded / AWG
24 V DC 10% 1A 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa AKB331, PxC YUC50/YCS50 14-pos. flat ribbon cable plug connector in acc. with IEC 603-1/DIN 41651 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Output:
Adapter PLC-V8/FLK14/OUT/M
Relay screw connection spring-cage screw connection spring-cage 2966171 PLC-RSC- 24DC/21 2966472 PLC-RSP- 24DC/21 2967060 PLC-RSC- 24DC/21-21 2912507 PLC-RSP- 24DC/21-21
ADV551: 2304102
ADV551: 2304306
PLC-V8L/FLK14/OUT/M
Input: ADV151:
Relay screw connection spring-cage 2966265 PLC-RSC- 24DC/21AU 2966540 PLC-RSP- 24DC/21AU
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 94 of 202
05/12/2012
Dimensional drawing:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 95 of 202
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 96 of 202
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 97 of 202
05/12/2012
VARIOFACE termination board for relay output modules These boards have been specially designed for coupling to the ADR541 modules with dedicated system cable AKB334. The following features characterize these boards: - Universal 1:1 connection - Redundant system power supply with monitoring - Two system connectors in parallel for redundant applications - Spring terminal connection to the field level - Fuse with LED indication per channel
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for relay cards ADR 541 Right side version Left side version
UM-4SL/SPT/ADR541/CS UM-4SL/SPT/ADR541/CS/C-L
2968522 2968548
1 1
Technical Data
Max. perm. operating voltage Max. total current (voltage supply) Max. total current for each channel Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
24 V DC 20% 6.3 A (5+, 3+), pluggable fuse 5X20, 6,3 AT 0.63 A, pluggable fuse 5X20, 0,63 AT 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa Usable system cables: Yokogawa AKB334 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 98 of 202
05/12/2012
Dimensional drawing:
8- 8+ 7- 7+ 6- 6+ 5- 5+ 4- 4+ 3- 3+ 2- 2+ 1- 1+
X4
X3
X2 A
1 18
18
18
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
Page 99 of 202
18
B
05/12/2012
X1
REL
X10
6 5 4 3 2 1
1+ 1- 2+ 2- 3+ 3- 4+ 4- 5+ 5- 6+ 6- 7+ 7- 8+ 89+ 9- 10+10-11+11-12+12-13+13-14+14-15+15-16+16-
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Screw connection to the field level - Following I/O-modules can be used: AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards (AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835) Technical Data
FLKM-KS40/YCS
2314642
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
Note: Connect short circuit on terminals 20A and 20B so that disconnected system cable can be detected
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Spring-cage connection to the field level - Redundant I/O connector - Separate marking strips are supplied for several I/O modules - Following I/O-modules can be used: AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards (AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835) Technical Data
FLKM-2KS40/YCS/ZFKDS
2314752
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
Field X10
1A
X1B X1A
40 40 39 39 38 38 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 29 29 28 28 27 27 26
Ch.
1B 2A 2B 3A 3B 4A 4B 5A 5B 6A 6B 7A 7B 8A 25 8B 24 9A 23 9B 22 10A 21 10B 20 11A 19 11B 18 12A 17 12B 16 13A 15 13B 14 14A 13 14B 12 15A 11 15B 10 16A 09 16B 08 17A 07 17B 06 18A 05 18B
26 25
24 23 22 21 20 19 18 17 16 15 14 13 12 11
10 09 08 07 06 05
02 01
02 01
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Separate marking strips are supplied for several I/O modules: AAV141 / AAV142 / AAT141:
AAI141 / AAI143:
AAV542 / AAI543:
AAI841:
AAB841:
AAI135 / AAP135:
AAI835:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
AAR 181:
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Srew connection to the field level - Redundant I/O connector - Separate marking strips are supplied for several I/O modules - Following I/O-modules can be used: AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards (AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835) Technical Data
FLKM-2KS40/YCS
2901056
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
Field X10
1A
X1B X1A
40 40 39 39 38 38 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 29 29 28 28 27 27 26
Ch.
1B 2A 2B 3A 3B 4A 4B 5A 5B 6A 6B 7A 7B 8A 25 8B 24 9A 23 9B 22 10A 21 10B 20 11A 19 11B 18 12A 17 12B 16 13A 15 13B 14 14A 13 14B 12 15A 11 15B 10 16A 09 16B 08 17A 07 17B 06 18A 05 18B
26 25
24 23 22 21 20 19 18 17 16 15 14 13 12 11
10 09 08 07 06 05
02 01
02 01
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Separate marking strips are supplied for several I/O modules: AAV141 / AAV142 / AAT141:
AAI141 / AAI143:
AAV542 / AAI543:
AAI841:
AAB841:
AAI135 / AAP135:
AAI835:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Spring terminal connection to the field level - Redundant I/O connector - Separate marking strips are supplied for several I/O modules - Following I/O-modules can be used: AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards (AAV141, AAV142, AAI141, AAI143, AAV542, AAI543, AAI135, AAI835, AAP135, AAT141, AAR181, AAB841, NFAI141, NFAI43, NFAI543, NFAI135, NFAP135, NFAV141, NFAV142, NFAV542, NFAB841, NFAI841, NFAI835) Right side version Left side version FLKM-2KS40/SPT/CS FLKM-2KS40/SPT/CS/C-L 2321826 2321855 1 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 1A 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 or Phoenix Contact YUC40 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Separate marking strips are supplied for several I/O modules: AAV141 / AAV142 / AAT141:
AAI141 / AAI143:
AAV542 / AAI543:
AAI841:
AAB841:
AAI135 / AAP135:
AAI835:
AAR 181:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules with knife disconnection These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Screw connection with knife disconnection to the field level - Redundant I/O connector - Soldering tags per channel - Following I/O-modules can be used: AAI141, AAI143, AAV141, AAV142, AAI543, AAV542, AAI841, AAB841, NFAI141, NFAI143, NFAI543, NFAI841, NFAB841, NFAV542, NFAV141, NFAV142
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards (AAI141, AAI143, AAV141, AAV142, AAI543, AAV542, AAI841, AAB841, NFAI141, NFAI143, NFAI543, NFAI841, NFAB841, NFAV542, NFAV141, NFAV142) Technical Data
FLKM-2KS40/PMT/ST/YCS
2321981
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 100mA 20 C to + 70 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 Phoenix Contact YUC40 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
8AI/8AO
Yokogawa
16AO X
16AI
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules with knife disconnection These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Spring terminal connection with knife disconnection to the field level - Redundant I/O connector - Soldering tags per channel - Following I/O-modules can be used: AAI141, AAI143, AAV141, AAV142, AAI543, AAV542, AAI841, AAB841, NFAI141, NFAI143, NFAI543, NFAI841, NFAB841, NFAV542, NFAV141, NFAV142
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards (AAI141, AAI143, AAV141, AAV142, AAI543, AAV542, AAI841, AAB841, NFAI141, NFAI143, NFAI543, NFAI841, NFAB841, NFAV542, NFAV141, NFAV142) Technical Data
FLKM-2KS40/PMT/ST/Z/YCS
2321994
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 100mA 20 C to + 70 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 Phoenix Contact YUC40 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
8AI/8AO
Yokogawa
16AO X
16AI
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
8AI/8AO X 8AI/8AO
Yokogawa
Yokogawa
16AO 16AO
16AI 16AI
1-
2-
3-
4-
5-
6-
7-
8-
O1-
O2-
O3-
O4-
O5-
O6-
07-
08-
126 111
Additional labelling
1+
2+
3+
4+
5+
6+
7+
8+
O1+
O2+
O3+
O4+
O5+
O6+
07+
08+
1+
1-
2+
2-
3+
3-
4+
4-
5+
5-
6+
6-
7+
7-
8+
8-
O1+ O1-
O3-
O4+
O4-
O5+ O5-
O6+ O6-
O7+
O7- O8+
O8-
181 180
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input This board has been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize this board: - Transmission of 16 channels with separate plus and minus terminals per channel - Redundant power supply, decoupled by diodes with heat sink - Spring-cage connection to the field level - Two system connectors in parallel for redundant applications. - Hart terminal - Following input modules can be used: AAI141, AAI143, NFAI141, NFAI143
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI141, AAI143, NFAI141, NFAI143) UM-2KS40/AI16/CS/Z/SO180 2311331 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 or Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input These boards have been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize these boards: - Transmission of 16 channels with separate plus and minus terminals per channel - Screw connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Two system connectors in parallel for redundant applications. - Following input modules can be used: AAI141, NFAI141 / AAI143, NFAI143 (has to be set in 4 wire mode)
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI 141, AAI143, NFAI141, NFAI143) FLKMS-KS40/AI/YCS 2314286 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input These boards have been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize these boards: - Transmission of 16 channels with separate plus and minus terminals per channel - Spring-cage connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Two system connectors in parallel for redundant applications. - Following input modules can be used: AAI141, NFAI141 / AAI143, NFAI143 (has to be set in 4 wire mode)
Note: Picture shows screw connection
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI 141, AAI143, NFAI141, NFAI143) FLKMS-KS40/AI/YCS/ZFKDS 2314710 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Dimensional drawing
126
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
PMB
PMB
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input These boards have been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize these boards: - Transmission of 16 channels with separate plus and minus terminals per channel - Pluggable fuse per plus connection with LED indication - Screw connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Two system connectors in parallel for redundant applications. - Following input modules can be used: AAI141, AAI143, AAI135 NFAI141, NFAI143, NFAI135 (has to be set in 4 wire mode)
Pcs. Pkt.
Description
Part Description
Order No.
VARIOFACE termination board for 16 channels (AAI141, AAI143, AAI135, NFAI141, NFAI143, NFAI135) FLKMS-KS40/SI/AI16/YCS 2314273 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA, pluggable fuse per plus connection (5X20, 0.1A) 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input These boards have been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize these boards: - Transmission of 16 channels - Screw connection to the field level - Two system connectors in parallel for redundant applications. - Following output modules can be used: AAI543, NFAI543
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI 543, NFAI543) FLKM-KS40/AO16/YCS 2314260 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 4 mm / 0,2 2,5mm / 24 12 0,5 0,6 Nm
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input These boards have been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize these boards: - Transmission of 16 channels - Spring-cage connection to the field level - Two system connectors in parallel for redundant applications. - Following output modules can be used: AAI543, NFAI543
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI 543, NFAI543) FLKM-KS40/AO16/YCS/ZFKDS 2314697 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for Analog I/O This board has been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize this board: - Transmission of 16 channels - Two system connectors in parallel for redundant applications - Spring-cage connection to the field level - Hart terminal - Switch function for AAI543 or AAI141/AAI143 - NFAI543 or NFAI141/NFAI143 - Following I/O-modules can be used: AAI543, AAI141, AAI143, NFAI543, NFAI141, NFAI143
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI543, AAI141, AAI143, NFAI543, NFAI141, NFAI143) UM-2KS40/AIO16/CS/Z/SO180 2311344 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 or Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input These boards have been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize these boards: - Transmission of 16 channels with separate plus and minus terminals per channel - PTC resettable fuse per plus connection with LED indication - Spring connection to the field level - Redundant power supply, decoupled by diodes with heat sink - Two system connectors in parallel for redundant applications. - Following input modules can be used: AAI141, AAI841 (has to be set in 4 wire mode)
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 16 channels (AAI141, AAI1841, NFAI141, NFAI841) FLKMS-2KS40/BFI/AIO16/Z/YCS 2901419 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Max. total current (voltage supply) Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
24 V DC 10% 100mA, PTC resettable fuse 2A (P1+, P2+), pluggable fuse (5X20, 2A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
Dimensional drawing
151
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection diagram for different sensor types. Note: System card AAI141/AAI143 has to be set in 4-wire mode! (See manual of AAI141/AAI143)
Sensor type:
X10
B Passive sensor + B Passive sensor + 1B 1C 1A 2B 2C 2A . . . Aktive sensor + To external powersupply
16B 16C
16A
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules with knife disconnection These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Screw connection with knife disconnection to the field level - Redundant I/O connector - Following I/O modules can be used: AAI135, AAI835, NFAI135, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards AAI135, NFAI135 (8AI) AAI835, NFAI835 (4AI/4AO) FLKM-2KS40/PMT/YCS 2321907 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14 0,5 0,6 Nm
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
X10
135
Dimensional drawing AAI835
X10
NC
1+
1-
NC
2+
2-
NC
3+
3-
NC
4+
4-
135
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules with knife disconnection These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Spring terminal connection with knife disconnection to the field level - Redundant I/O connector - Following I/O modules can be used: AAI135, AAI835, NFAI135, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards AAI135, NFAI135 (8AI) AAI835, NFAI835 (4AI/4AO) FLKM-2KS40/PMT/Z/YCS 2321978 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 Phoenix Contact YUC40 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
77
1A 1B 1 C 2A 2B 2C 3A 3B 3C 4A 4B 4C NC 1+ 1-
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
PMB
X1A
39 40
1 2
4AI/ 4AO X
Yokoga wa
8AI
X1B
39 40
1 2
PMB
X10
NC 2+ 2-
NC 3+ 3-
NC 4+ 4-
135
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules with knife disconnection These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Screw connection with knife disconnection to the field level - Redundant I/O connector - External / internal loop supply depending on jumper setting - Fuse per channel - Following I/O modules can be used: AAI135, AAI835, NFAI135, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards AAI135, NFAI135 (8AI) AA 835, NFAI835 (4AI/4AO) Component parts
FLKM-2KS40/PMT/SI/YCS
2901034
VF-SI/TR5/0,1AT
2901008
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG Tightening torque
24 V DC 10% 100mA, pluggable fuse (IEC 60127-3, 0.1A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14 0,5 0,6 Nm
Dimensional drawing
126
1A 1B 2A 2B 3A 3B 4A 4B 5A 5B 6A 6B 7A 7B 8A 8B
92,5
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O modules with knife disconnection These boards have been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize these boards: - Spring terminal connection with knife disconnection to the field level - Redundant I/O connector - External / internal loop supply depending on jumper setting - Fuse per channel - Following I/O modules can be used: AAI135, AAI835, NFAI135, NFAI835
Description
Part Description
Order No
Pcs. Pkt.
VARIOFACE termination board for analog I/O cards AAI 135, NFAI135 (8AI) AAI 835, NFAI835 (4AI/4AO) Component parts
FLKM-2KS40/PMT/SI/Z/YCS
2321936
VF-SI/TR5/0,05AT
2900999
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection data solid / stranded / AWG
24 V DC 10% 100mA, pluggable fuse (IEC 60127-3, 0.1A) 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1, Phoenix Contact YUC40 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Dimensional drawing
Delivery status: Jumpers are in the following position: Analog IN/OUT External PW
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog input This board has been specially designed for coupling to the analog input modules with dedicated system cables. The following features characterize this board: - Transmission of 8 channels with separate plus and minus terminals per channel - Spring-cage connection - Two system connectors in parallel for redundant applications. - Hart terminal - Following input modules can be used: AAI135, AAP135, AAR181, AAT141, AAV141, AAV142, NFAI135, NFAV141, NFAV142
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 8 channels (AAI135, AAP135, AAR181, AAT141, AAV141, AAV142, NFAI135, NFAV141, NFAV142) UM-2KS40/AI 8/CS/Z/SO180 Technical Data 2311386 1
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 or Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
C1
C3
C5
08+
07+
06+
05+
04+
03+
02+
01+
C8
C7
128 126
108
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection Scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for analog I/O This board has been specially designed for coupling to the analog I/O modules with dedicated system cables. The following features characterize this board: - Transmission of 4 input and 4 output channels - Spring-cage connection to the field level - Two system connectors in parallel for redundant applications. - Hart terminal. - Following I/O modules can be used: AAB841, AAV542, AAI835, NFAI835, NFAB841 NFAV542
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE termination board for 4 input and 4 output channels (AAB841, AAV542, AAI835, NFAI835, NFAB841, NFAV542) UM-2KS40/AIO 8/CS/Z/SO180 2311357 1
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O Connection to HART multiplexer
24 V DC 10% 100mA 20 C to + 50 C any DIN EN 50178, contamination class 2, surge voltage category II, basic isolation 2 X Yokogawa KS compatible connector, 40pins Usable system cables: Yokogawa KS1 or Phoenix Contact YUC40 Optional a HART connector (26pins) for use with Pepperl+Fuchs cable type K-HM26, in parallel with the system connectors links to the Pepperl+Fuchs HART multiplexer 2 2 0,2 2,5 mm / 0,2 1,5mm / 24 14
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Connection scheme:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE termination board for RTD modules These boards have been specially designed for coupling to the RTD modules with dedicated system cables. The following features characterize these boards: - Universal 1:1 connection - Spring-cage connection to the field level - Redundant I/O connector - Following RTD modules can be used: AAR145
Description
Part Description
Order No
Pcs. Pkt.
Technical Data
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations Connection to I/O
24 V DC 10% 100mA 20 C to + 70 C any DIN EN 50178, contamination class 2, surge voltage category III, basic isolation 2 X Yokogawa KS compatible connector, 50pins Usable system cables: Yokogawa KS8 or Phoenix Contact FLK-MIL50/EZ-DR/KS//YCS 2 2 0,2 4 mm / 0,2 2,5mm / 24 12
Dimensional drawing
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Application diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
VARIOFACE V8 adapter for MINI Analog signal converters The PLC-V8 adapter is simply inserted in the contact slots of eight MINI Analog signal converters by the new plug-in concept. These eight modules are easily connected to a control unit by means of pluggable system cabling. Connection of 16 MINI Analog signal converters to Yokogawa CS3000 by CABLE-40/2FLK16//YUC
Description
Part Description
Order No.
Pcs. Pkt. 1
2811268
Max. perm. operating voltage Max. perm. continuous current per signal Ambient temperature range Installation position Standards/regulations ATEX approval Dimensions (H x W x L) Connection to I/O Number of Positions Connection to YOKOGAWA Centum CS3000 R3
24 V AC/DC 10% 1A 20 C to + 60 C any IEC 60664 /IEC 60664A /DIN VDE 0110,
II 3 G Ex nA II T4 X, UL, USA/Canada 45,5 x 50,4 x 46,2 mm Flat-ribbon cable connector, 16-pos. (FLK 16) 16 CABLE-40/2FLK16//YUC
Connection Diagram:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Termination Carrier board for 32 channel analog input cards This board has been specially designed for coupling to the digital input cards with dedicated system cables. The following features characterize this board: - Transmission of 32 DI channels - two KS50 male cable connector for redundant applications - redundant power supply - Following I/O cards can be connected: ADV151, ADV161, NFDV151, NFDV161
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay input/output module for 16 channels (ADV151, ADV161, NFDV151, NFDV161) Component parts
TC-2KS50-DI32-M-MR-CS
2903571
MINI MCR-SL-NAM-2RNO MINI MCR-SL-PTB-FM MINI MCR-SL-FM-RC-NC TC-C-2MIN-SC-05061516 (included) TC-C-PTB1-SC-05060708 (included) EMLF (108XE)R ZBF 15 FBS 2-6 Technical Data
1 1 1 1 1 1 1 1
Operating voltage Ambient temperature range Mounting position Standards/regulations dimensions A/B/C Connector X1.A / 1.B Conncector X20 type of connection connection data solid mm / stranded mm / AWG *) with mounted modules Dimensional drawing
24 V DC (19,2 - 30V DC) * - 40 C 80 C any DIN EN 50178, contamination class 2, surge voltage category II 160mm, 170mm, 242mm KS50 Combicon connector 6 positions screw connection 0,14 - 2,5 / 0,14 - 2,5 / 26 - 14
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Termination Carrier board for 16 channel analog input / output cards This board has been specially designed for coupling to the analog input/output cards with dedicated system cables. The following features characterize this board: - Transmission of 16 AIO channels - two KS40 male cable connector for redundant applications - redundant power supply - Following I/O cards can be connected: AAI543, AAI141, NFAI141, NFAI543
Description
Part Description
Order No.
Pcs. Pkt.
VARIOFACE relay input/output module for 16 channels (AAI543, AAI141, NFAI141, NFAI543) TC-2KS40-AIO16R-CS3000 Component parts MACX MCR-EX-SL-IDSI-I AO MACX MCR-EX-SL-RPSSI-I AI MACX MCR-PTB TC-C-MAX2-SC-31320000 TC-C-PTB3-SC-31001112-33002122 ME 6,2 TBUS-2 1,5/5-ST-3,81 GN ZBF 15: 2x 2 /Termination Carrier Technical Data 2865405 2865340 2865625 2902425 2902656 2869728 0811202 1 1 1 1 1 1 1 2902661 1
Operating voltage Typ. input current per channel Ambient temperature range Mounting position Standards/regulations dimensions A/B/C Connector X1.A / 1.B Conncector X20 type of connection connection data solid mm / stranded mm / AWG *) with mounted modules Dimensional drawing
24 V DC (19,7 - 30V) * 800 mA - 20 C 60 C any DIN EN 50178, contamination class 2, surge voltage category II 160mm, 170mm, 244mm KS40 Combicon connector 6 positions screw connection 0,34 - 2,5 / 0,2 - 2,5 / 24 - 12
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Analog In:
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
System cables for YOKOGAWA These pre-assembled system cables with overmoulded connectors are plugged onto the CENTUM I/O-cards with 50-pos. or 40-pos. MIL connectors. A special adapter is not necessary. The cable connector on the other side can be plugged on all termination boards using KS or AKB compatible connectors: - FLK 50-PA/YUC: 50 position connectors on both ends (1:1 connection) - FLK 40-PA/YUC: 40 position connectors on both ends (1:1 connection)
50-pos. YUC cables: 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0 11,0 12,0 13,0 14,0 15,0 16,0 17,0 18,0 19,0 20,0 25,0 30,0 40-pos. YUC cables: 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0 11,0 12,0 13,0 14,0 15,0 16,0 17,0 18,0 19,0 20,0 25,0 30,0 35,0 40,0 45,0 FLK 40-PA/EZ-DR/KS/ 100/YUC FLK 40-PA/EZ-DR/KS/200/YUC FLK 40-PA/EZ-DR/KS/300/YUC FLK 40-PA/EZ-DR/KS/400/YUC FLK 40-PA/EZ-DR/KS/ 500/YUC FLK 40-PA/EZ-DR/KS/600/YUC FLK 40-PA/EZ-DR/KS/ 700/YUC FLK 40-PA/EZ-DR/KS/800/YUC FLK 40-PA/EZ-DR/KS/ 900/YUC FLK 40-PA/EZ-DR/KS/1000/YUC FLK 40-PA/EZ-DR/KS/1100/YUC FLK 40-PA/EZ-DR/KS/1200/YUC FLK 40-PA/EZ-DR/KS/1300/YUC FLK 40-PA/EZ-DR/KS/1400/YUC FLK 40-PA/EZ-DR/KS/1500/YUC FLK 40-PA/EZ-DR/KS/1600/YUC FLK 40-PA/EZ-DR/KS/1700/YUC FLK 40-PA/EZ-DR/KS/1800/YUC FLK 40-PA/EZ-DR/KS/1900/YUC FLK 40-PA/EZ-DR/KS/2000/YUC FLK 40-PA/EZ-DR/KS/2500/YUC FLK 40-PA/EZ-DR/KS/3000/YUC FLK 40-PA/EZ-DR/KS/3500/YUC FLK 40-PA/EZ-DR/KS/4000/YUC FLK 40-PA/EZ-DR/KS/4500/YUC 23 22 786 23 14 341 23 14 354 23 14 367 23 21 570 23 14 943 23 21 583 23 14 956 23 21 415 23 14 370 23 21 428 23 21 431 23 21 444 23 21 457 23 14 383 23 21 596 23 21 606 23 21 619 23 21 622 23 14 532 23 14 545 23 14 558 29 01 017 29 01 052 29 02 912 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 FLK 50-PA/EZ-DR/KS/100/YUC FLK 50-PA/EZ-DR/KS/200/YUC FLK 50-PA/EZ-DR/KS/300/YUC FLK 50-PA/EZ-DR/KS/400/YUC FLK 50-PA/EZ-DR/KS/500/YUC FLK 50-PA/EZ-DR/KS/600/YUC FLK 50-PA/EZ-DR/KS/700/YUC FLK 50-PA/EZ-DR/KS/800/YUC FLK 50-PA/EZ-DR/KS/900/YUC FLK 50-PA/EZ-DR/KS/1000/YUC FLK 50-PA/EZ-DR/KS/1100/YUC FLK 50-PA/EZ-DR/KS/1200/YUC FLK 50-PA/EZ-DR/KS/1300/YUC FLK 50-PA/EZ-DR/KS/1400/YUC FLK 50-PA/EZ-DR/KS/1500/YUC FLK 50-PA/EZ-DR/KS/1600/YUC FLK 50-PA/EZ-DR/KS/1700/YUC FLK 50-PA/EZ-DR/KS/1800/YUC FLK 50-PA/EZ-DR/KS/1900/YUC FLK 50-PA/EZ-DR/KS/2000/YUC FLK 50-PA/EZ-DR/KS/2500/YUC FLK 50-PA/EZ-DR/KS/3000/YUC 29 00 991 23 14 299 23 14 309 23 14 312 23 21 499 23 14 927 23 21 509 23 14 930 23 21 512 23 14 325 23 21 389 23 21 525 23 21 392 23 21 402 23 14 338 23 21 538 23 21 541 23 21 554 23 21 567 23 14 503 23 14 516 23 14 529 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Technical Data Maximum operating voltage Maximum current carrying capacity per path Test voltage Operating temperature Conductor gage/cross-section Strands Outer diameter Assembly Connector: 30 V AC/DC 500 mA 0,8kV 20 C to + 70 C 2 AWG26 / 0,14 mm 7 litz wires, Cu tin-plated 11 mm IDC IEC 352-4/DIN EN60 352-4 50 position (FLK 50-PA/YUC, FLK 50-PA/YOC) 40 position (FLK 40-PA/YUC) Glass filled Polyester, Flammability acc. to UL94: V0 Macromelt, Flammability acc. to UL94: V0 Cable jacket, insulating material of conductors: PVC Shield: Braided shielding made of galvanized copper wires General flammability resistance: UL1581, DIN EN 60332-1 Max conductor resistance: < 145 /km
FLK 50-PA/EZ-DR/KS//YUC:
50 pos. connector for Core color termination module 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 Black Brown Red Orange Yellow Green Blue Violet Gray White White-black White-brown White-red White-orange White-yellow White-green White-blue White-violet White-gray Brown-black Brown-red Brown-orange Brown-yellow Brown-green Brown-blue Brown-violet Brown-gray Brown-white Green-black Green-brown Green-red Green-orange Green-blue Green-violet Green-gray Green-white Yellow-black Yellow-brown Yellow-red Yellow-orange Yellow-blue Yellow-violet Yellow-gray Yellow-white Gray-black Gray-brown Gray-red Gray-orange Gray-yellow Gray-green
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
FLK 40-PA/EZ-DR/KS//YUC: 40-pos. connector for I/O card 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 40 pos. connector for termination module 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
Core color
Black Brown Red Orange Yellow Green Blue Violet Gray White White-black White-brown White-red White-orange White-yellow White-green White-blue White-violet White-gray Brown-black Brown-red Brown-orange Brown-yellow Brown-green Brown-blue Brown-violet Brown-gray Brown-white Green-black Green-brown Green-red Green-orange Green-blue Green-violet Green-gray Green-white Yellow-black Yellow-brown Yellow-red Yellow-orange
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Splitting cables for YOKOGAWA These pre-assembled system cables with overmoulded connectors at the I/O module side are plugged onto the CENTUM I/O-cards with 50-pos. connectors. A special adapter is not necessary. The cable connector on the other side can be plugged onto the VARIOFACE V8 adapter for PLC Relay.
CABLE-50/4FLK14//YUC
Description Cable Length [m] 2,0 3,0 4,0 6,0 10,0 15,0 20,0 22,0 28,0 50,0 Part Description Order No. Pcs. Pkg.
50-pos to 4X14pos. splitting cables for ADV 151, ADV551, NFDAV 151, NFDAV161
CABLE-50/4FLK14/2,0M/YUC CABLE-50/4FLK14/3,0M/YUC CABLE-50/4FLK14/4,0M/YUC CABLE-50/4FLK14/6,0M/YUC CABLE-50/4FLK14/10,0M/YUC CABLE-50/4FLK14/15,0M/YUC CABLE-50/4FLK14/20,0M/YUC CABLE-50/4FLK14/22,0M/YUC CABLE-50/4FLK14/28,0M/YUC CABLE-50/4FLK14/50,0M/YUC
23 14 23 14 23 14 23 18 23 14 23 22 23 14 29 02 29 01 23 14
655 668 671 978 684 773 778 800 386 765
1 1 1 1 1 1 1 1 1 1
Technical Data Maximum operating voltage Maximum current carrying capacity per path Test voltage Operating temperature Conductor gage/cross-section Strands Outer diameter Assembly Connector: 30 V AC/DC 500 mA 0,8kV 20 C to + 70 C 2 AWG26 / 0,14 mm 7 litz wires, Cu tin-plated 11 mm IDC IEC 352-4/DIN EN60 352-4 50 position (I/O module) 4 X 14 position (Termination board) Glass filled Polyester, Flammability acc. to UL94: V0 Macromelt, Flammability acc. to UL94: V0 Cable jacket, insulating material of conductors: PVC Shield: Braided shielding made of galvanized copper wires General flammability resistance: UL1581, DIN EN 60332-1 Max conductor resistance: < 145 /km
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
X1
X2
X3
X4
X5
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
X1
X2
X3
X4
X5
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Splitting cables for YOKOGAWA 64 channel I/O modules These pre-assembled system cables with 50 position connectors at the I/O module side are plugged onto the CENTUM I/O-cards with two 50-pos. connectors. For each I/O module two of these cables are necessary. The cable connector on the other side can be plugged onto the VARIOFACE V8 adapter for PLC Relay.
FLKMIL-50/4FLK14//CS
Description
Part Description
50-pos to 4X14pos. splitting cables for ADV 161, ADV561, NFDAV 161, NFDAV561:
1,0 2,0 3,0 5,0 6,0 10,0 15,0 20,0 30,0 45,0
FLKMIL-50/4FLK14/EZ-DR/100/CS FLKMIL-50/4FLK14/EZ-DR/200/CS FLKMIL-50/4FLK14/EZ-DR/300/CS FLKMIL-50/4FLK14/EZ-DR/500/CS FLKMIL-50/4FLK14/EZ-DR/600/CS FLKMIL-50/4FLK14/EZ-DR/1000/CS FLKMIL-50/4FLK14/EZ-DR/1500/CS FLKMIL-50/4FLK14/EZ-DR/2000/CS FLKMIL-50/4FLK14/EZ-DR/3000/CS FLKMIL-50/4FLK14/EZ-DR/4500/CS
23 06 951 23 06 304 23 06 964 23 06 977 23 18 949 23 06 980 23 01 503 23 01 914 29 00 159 29 02 911
1 1 1 1 1 1 1 1 1 1
Technical Data Maximum operating voltage Maximum current carrying capacity per path Test voltage Operating temperature Conductor gage/cross-section Strands Outer diameter Assembly Connector: 30 V AC/DC 500 mA 0,8kV 20 C to + 70 C 2 AWG26 / 0,14 mm 7 litz wires, Cu tin-plated 11 mm IDC IEC 352-4/DIN EN60 352-4 50 position (I/O module) 4 X 14 position (Termination board) Glass filled Polyester, Flammability acc. to UL94: V0 Cable jacket, insulating material of conductors: PVC Shield: Braided shielding made of galvanized copper wires General flammability resistance: UL1581, DIN EN 60332-1 Max conductor resistance: < 145 /km
Cable
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
2 Coding Pin
X1 X2
49 50
X3
X4
X5
X1
X2
X3
X4
X5
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
System cables for YOKOGAWA 64 channel I/O modules These pre-assembled system cables with 50 position connectors at the I/O module side are plugged onto the CENTUM I/O-cards with two 50-pos. connectors. For each I/O module two of these cables are necessary. The cable connector on the other side can be plugged on all termination boards using 50pos. KS or AKB compatible connectors
FLK- MIL-50/EZ-DR/KS//YCS
Cable Length [m] 2,0 3,0 4,0 10,0 15,0 20,0 30,0 35,0 40,0 45,0 80,0 Pcs. Pkg.
Description
Part Description
Order No.
50-pos. cables: FLK- MIL-50/EZ-DR/KS/200/YCS FLK- MIL-50/EZ-DR/KS/300/YCS FLK- MIL-50/EZ-DR/KS/400/YCS FLK- MIL-50/EZ-DR/KS/1000/YCS FLK- MIL-50/EZ-DR/KS/1500/YCS FLK- MIL-50/EZ-DR/KS/2000/YCS FLK- MIL-50/EZ-DR/KS/3000/YCS FLK- MIL-50/EZ-DR/KS/3500/YCS FLK- MIL-50/EZ-DR/KS/4000/YCS FLK- MIL-50/EZ-DR/KS/4500/YCS FLK- MIL-50/EZ-DR/KS/8000/YCS 23 14 590 23 14 781 23 14 794 23 14 804 23 14 817 23 14 820 29 01 018 29 01 019 29 01 020 29 02 909 23 21 868 1 1 1 1 1 1 1 1 1 1 1
Technical Data Maximum operating voltage Maximum current carrying capacity per path Test voltage Operating temperature Conductor gage/cross-section Strands Outer diameter Assembly Connector: Overmoulded connector housing: Cable 30 V AC/DC 500 mA 0,8kV 20 C to + 70 C 2 AWG26 / 0,14 mm 7 litz wires, Cu tin-plated 11 mm IDC IEC 352-4/DIN EN60 352-4 50 position Glass filled Polyester, Flammability acc. to UL94: V0 Macromelt, Flammability acc. to UL94: V0 Cable jacket, insulating material of conductors: PVC Shield: Braided shielding made of galvanized copper wires General flammability resistance: UL1581, DIN EN 60332-1 Max conductor resistance: < 145 /km
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
2 Coding Pin
X1
X2
X1
49 50
X2
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
System cables for YOKOGAWA 16 channel analog I/O modules These pre-assembled system cables with 40 position connectors at the I/O module side are plugged onto two 8-channel MINI analog system adapters with two 16-pos. connectors. Usable for Yokogawa Cards AAI141, AAI143, NFAI141, NFAI143
CABLE-40/2FLK16//YUC
Description
Part Description
Order No.
Pcs. Pkg.
50-pos. cables: 2,0 4,0 10,0 15,0 20,0 CABLE-40/2FLK16/ 2,0M/YUC CABLE-40/2FLK16/ 4,0M/YUC CABLE-40/2FLK16/10,0M/YUC CABLE-40/2FLK16/15,0M/YUC CABLE-40/2FLK16/20,0M/YUC 23 21 23 21 23 21 23 21 23 21 334 347 350 376 363 1 1 1 1 1
Technical Data Maximum operating voltage Maximum current carrying capacity per path Number of positions, control side Number of positions, module side Number of connectors, module side Operating temperature Conductor gage/cross-section Strands Outer diameter Max. conductor resistance 30 V AC/DC 500 mA 40 16 2 20 C to + 50 C 2 AWG26 / 0,14 mm 7 litz wires, Cu tin-plated 11 mm 0,16 /m
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012
Phoenix Contact GmbH & Co. KG 32823 Blomberg Germany Phone +49-(0) 52 35-3-00 Fax +49-(0) 52 35-3-4 12 00 http://www.phoenixcontact.com
PYSF06
Technische nderungen und Irrtmer vorbehalten / Modifications and errors reserved
05/12/2012