You are on page 1of 310

ACS550

Users Manual ACS550-01 Drives (0.75132 kW) ACS550-U1 Drives (1200 hp)

ACS550 Drive Manuals


GENERAL MANUALS ACS550-01/U1 User's Manual (0.75132 kW) / 3AFE64804588 (3AUA0000001418) (English) ACS550-02/U2 User's Manual (160355 kW) / (200550 hp) 3AFE64804626 (English) Safety Installation Start-up, control with I/O and ID Run Control panels Application macros Parameters Embedded fieldbus Fieldbus adapter Diagnostics Maintenance Technical data ACS550 Technical Reference Manual (available in electronic format only) Detailed Product Description Technical product description including dimensional drawings Cabinet mounting information including power losses Software and control including complete parameter descriptions User interfaces and control connections Complete options descriptions Spare parts Etc. Practical Engineering Guides PID & PFC engineering guides Dimensioning and sizing guidelines Diagnostics and maintenance information Etc. The IndustrialIT wordmark and Product names in the form DriveIT are registered or pending trademarks of ABB. CANopen is a registered trademark of CAN in Automation e.V. ControlNet is a registered trademark of ControlNet International. DeviceNet is a registered trademark of Open DeviceNet Vendor Association. DRIVECOM is a registered trademark of DRIVECOM User Organization. Interbus is a registered trademark of Interbus Club. LonWorks is a registered trademark of Echelon Corp. Metasys is a registered trademark of Johnson Controls Inc. Modbus and Modbus Plus are registered trademarks of Schneider Automation Inc. PROFIBUS is a registered trademark of Profibus Trade Org. PROFIBUS-DP is a registered trademark of Siemens AG. Guide for Capacitor Reforming in ACS50/150/350/550 3AFE68735190 (EN) MAINTENANCE MANUALS MFDT-01 FlashDrop Users Manual 3AFE68591074 (English) OHDI-01 115/230 V Digital Input Module User's Manual 3AUA0000003101 (English) OREL-01 Relay Output Extension Module User's Manual 3AUA0000001935 (English) OTAC-01 Users Manual Pulse Encoder Interface Module Users Manual 3AUA0000001938 (English). RCAN-01 CANopen Adapter User's Manual 3AFE64504231 (English) RCNA-01 ControlNet Adapter User's Manual 3AFE64506005 (English) RDNA-01 DeviceNet Adapter User's Manual 3AFE64504223 (English) RETA-01 Ethernet Adapter User's Manual 3AFE64539736 (English) RLON-01 LonWorks Adapter Module Users Manual 3AFE64798693 (English) RPBA-01 PROFIBUS-DP Adapter User's Manual 3AFE64504215 (English) Typical contents Safety Installation Programming/Start-up Diagnostics Technical data OPTION MANUALS (delivered with optional equipment)

ACS550-01/U1 Drives 0.75132 kW 1200 hp

Users Manual

3AFE64804588 (3AUA0000001418) Rev F EN EFFECTIVE: 16.04.2007 SUPERSEDES: 3AFE64804588 Rev D 24.06.2004 SUPERSEDES: 3AUA0000001418 Rev E 06.12.2004 2007 ABB Oy. All Rights Reserved.

ACS550 Users Manual

Safety

S dng cc cnh bo v ch :
C hai loi hng dn an ton xuyn sut hng dn s dng ny : v ghi ch cnh bo n iu kin c bit hoc thc trng, hoc cung cp thng tin trn mt ch . Cnh bo phng bn v cc iu kin m c th dn n thit hi nghim trng hoc t vong v/hoc thit hi cho thit b . H cng cho bn bit lm th no trnh nguy c. Cc biu tng cnh bo c dng nh sau : Cnh bo in p nguy him ca in p cao c th gy ra thit hi v vt cht v/hoc thit hi cho thit b . Cnh bo bnh thng cnh bo iu kin, khc hn gy ra bi in , m c th dn n chn thng v/hoc thit hi cho thit b .

Cnh bo! ACS550 iu chnh tc ng c AC ch nn lp t bi mt th in iu kin .

Cnh bo ! ngay c khi ng c dng li , c in p nguy him ti u ni ngun mch in U1, V1, W1 v U2, V2, W2 v, ty thuc vo kich thc khung , UDC+ v UDC-, hoc BRK+ v BRK-.

Cnh bo! Hin ti c in p nguy him khi u vo ngun in c kt ni. Sau khi ngt kt ni ngun cung cp, ch t nht 5 pht ( x ht t trong mch trung gian ) trc khi tho np .

Cnh bo ! ngay c khi ngun in c tc t cc u ni ng vo ca ACS550, c th c in p nguy him (t ngun bn ngoi) trn u ni ca u ra relay RO1RO3.

Cnh bo ! khi u ni kim sot ca hai hoc nhiu bin tn c kt ni song song , in p ph cho kim sot kt ni ny phi c ly t mt ngun duy nht c th l mt trong nhng bin tn hoc ngun cung cp bn ngoi .

Safety

ACS550 Users Manual

Cnh bo ! nu bin tn c b lc bn trong EMC khng b ngt kt ni c lp t trn h thng IT [mt h thng ngun in khng c ni t hoc ni t tr khng cao (trn 30 ohm) h thng in ], h thng s c kt ni n in th t thng qua t lc EMC ca bin tn . iu ny c th gy nguy him hoc h bin tn . Nu bin tn c b lc bn trong EMC khng b ngt kt ni c lp t trn gc ca h thng ni t TN, bin tn s b h . Ngt kt ni b lc bn trong EMC bi g b vt EM1 v EM3 (kch thc khung R1R4, xem biu trong phn Power connection diagrams trn trang 20) hoc vt F1 v F2 (kch thc khung R5 hoc R6, xem biu trn trang 21). Xem thm phn IT systems trn trang 268 v Corner grounded TN systems trn trang 267.

Cnh bo ! ng c gn lp t hoc g b vt EM1, EM3, F1 hoc F2 khi ngun in c cp n u vo u ni bin tn .

Cnh bo ! khng kim sot ng c vi cc thit b ngt (bin php ngt kt ni );thay vo , s dng bng iu khin khi ng v dng phm v lnh thng qua board I/O ca bin tn. S ln nht cho php ca chu k np ca t in DC (i.e. ngun in ln lc cp ngun) l su trong mi pht.

, hoc

Cnh bo ! ACS550-01/U1 khng c kh nng sa cha . Khng bao gi c gn sa cha mt bin tn b hng ; lin h vi nh my hoc trung tm dch v a phng bn c thay th .

cnh bo ! ACS550 t ng khi ng sau khi gin on in p u vo nu lnh chy bn ngoi l bt .

Cnh bo ! tng nhit c th t n nhit cao. Xem chng Technical data trn trang 259.

Ch : bit thm chi tit thng tin k thut, lin h vi nh my hoc i din ABB ca bn .

Safety

ACS550 Users Manual

Table of contents

Safety Use of warnings and notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Table of contents Installation Installation flow chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Preparing for installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Installing the drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Start-up, control with I/O and ID Run How to start up the drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 How to control the drive through the I/O interface . . . . . . . . . . . . . . . . . . . . . . 38 How to perform the ID Run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Control panels About control panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assistant Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Basic Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application macros ABB Standard macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-wire macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Alternate macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor Potentiometer macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hand-Auto macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PID Control macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PFC macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Torque Control macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connection example of a two-wire sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . User parameter sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Macro default values for parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Parameters Complete parameter list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85 Complete parameter descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98 Embedded fieldbus Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical and electrical installation EFB . . . . . . . . . . . . . . . . . . . . . . . . . Communication set-up EFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Activate drive control functions EFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 190 190 191 193 72 73 74 75 76 77 78 79 80 81 82 41 41 42 62

Table of contents

ACS550 Users Manual

Feedback from the drive EFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagnostics EFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modbus protocol technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABB control profiles technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fieldbus adapter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Planning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical and electrical installation FBA . . . . . . . . . . . . . . . . . . . . . . . . . Communication set-up FBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Activate drive control functions FBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Feedback from the drive FBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagnostics FBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ABB Drives profile technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Generic profile technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diagnostics Diagnostic displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 Correcting faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 Correcting alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 Maintenance Maintenance intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heatsink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Main fan replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internal enclosure fan replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical data Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Input power connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Motor connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Brake components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Control connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions and weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Degrees of protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ambient conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Applicable standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . C-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . UL/CSA markings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IEC/EN 61800-3 (2004) Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Compliance with the IEC/EN 61800-3 (2004) . . . . . . . . . . . . . . . . . . . . . . . . . Liability limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product protection in the USA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

197 198 201 209

221 223 224 225 225 228 229 232 240

255 255 256 257 258 258

259 263 271 277 281 282 283 286 289 289 290 291 291 291 292 292 293 294 295

Table of contents

ACS550 Users Manual

Index Contact ABB Product and service inquiries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 Product training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 Providing feedback on ABB Drives manuals . . . . . . . . . . . . . . . . . . . . . . . . . 309

Table of contents

10

ACS550 Users Manual

Table of contents

ACS550 Users Manual

11

Installation
Nghin cu k cc hng dn lp t trc khi tin hnh. Nu khng thc hin cc cnh bo v hng dn c th gy ra s c hoc nguy him ring . Cnh bo! Trc tin bn c chng Safety trn trang 5. Lu : vic lp t lun lun phi c thit k v thc hin theo php lut v quy nh ca a phng . ABB khng chu bt k trch nhim no cho bt k lp t quy phm php lut a phng v/hoc cc quy nh khc. Hn na, nu cc khuyn ngh c a ra bi ABB khng khng c thc hin, bin tn c th gp s c bo hnh khng khng bao gm v .

Installation flow chart


Lp t ca ACS550 iu chnh tc bin tn AC sau y l tm tc bn di. cc bc phi thc hin theo th t hin th. bn phi mi bc c tham chiu n cc thng tin chi tit cn thit cho vic lp t chnh xc bin tn .
Task Chun b cho vic lp t xem Preparing for installation trn trang 12

Chun b v tr lp

Prepare the mounting location trn trang 16

G b v mt trc

Remove the front cover trn trang 16

Gn bin tn

Mount the drive trn trang 17

Lp t dy dn

Wiring overview trn trang 18 v Install the wiring trn trang 24

Kim tra lp t

Check installation trn trang 29

Lp t v

Reinstall the cover trn trang 30

START-UP

How to start up the drive trn trang 31

Installation

12

ACS550 Users Manual

Preparing for installation


Lifting the drive Ch nng bin tn bng khung kim loi. Unpacking the drive 1. Tho bin tn . 2. Kim tra bt k h hi v thng bo cho ngi gi ngay lp tc nu b phn h hng c tm thy . 3. Kim tra ni dung chng li trnh t v nhn hng xc minh rng tt c cc phn bin tn nhn c . Drive identification Drive labels xc nh loi bin tn bn lp t, tham chiu hoc l : s serial c gn cht trn b phn ca chokeplate gia khung my hoc
Type code

IP2040

Serial number

loi m nhn nm trn tng nhit bn ba phi ca bin tn. hai v d ca loi m nhn c a ra di y .

Serial number Type code

Serial number

Type code

Installation

ACS550 Users Manual

13

Type code S dng biu sau y gii thch cc loi m tm thy trn c hai loi v s serial ca nhn .
ACS550-01-08A8-4+J404+
AC, Standard Drive 550 product series Construction (region specific) 01 = Setup and parts specific to IEC installation and compliance U1 = Setup and parts specific to US installation and NEMA compliance Output current rating e.g. 08A8 = 8.8 A, xem phn Ratings trn trang 259 bit thm chi tit Voltage rating 2 = 208240 V AC 4 = 380480 V AC 6 = 500600 V AC Options Examples of options: B055 = IP54 / UL type 12 (no specification = IP21 / UL type 1) 0J400 = No control panel J404 = ACS-CP-C Basic Control Panel L511 = OREL-01 Relay output extension K451 = RDNA-01 DeviceNet K452 = RLON-01 LonWorks K454 = RPBA-01 PROFIBUS DP

Ratings and frame size Biu trong phn Ratings trn trang 259 danh sch chi tit k thut v xc nh kch thc khung ca bin tn, v mt s hng dn trong ti liu ny c khc nhau, ty thuc vo kch thc khung ca bin tn. c bng phn loi, bn cn loi u ra dng in nhp t loi m. Ngoi ra, khi s dng bng phn loi, lu rng bng c chia thnh cc phn da trn bin tn phm vi in p . Serial number Cc nh dng s serial bin tn hin th trn nhn c m t di y .
S Serial l nh dng CYYWWXXXXX, trong C: YY: WW: nc sn xut nm sn xut tun sn xut ; 01, 02, 03, cho tun 1, tun 2, tun 3,

XXXXX: s nguyn mi tun bt u t 0001.

Installation

14

ACS550 Users Manual

Motor compatibility ng c, bin tn v ngun cung cp phi ph hp :


Motor specification Motor type Nominal current Verify 3-pha ng c cm ng Gi tr ng c l trong phm vi ny : 0.22.0 I2hd (I2hd = dng in ti nng ng c) 10500 Hz loi nhn trn bin tn, nhp cho u ra I2hd, hoc loi m trn bin tn v bng phn loi trong chng Technical data trn trang 259. Reference

Nominal frequency Voltage range

ng c tng thch vi 208240 V (cho ACS550-X1-XXXX-2) or ACS550 phm vi in p. 380480 V (cho ACS550-X1-XXXX-4) or 500600 V (cho ACS550-U1-XXXX-6) 500600 V bin tn: hoc Cho ACS550-U1-XXXX-6 ng c tun th NEMA MG1 Part 31, hoc mt b lc du/dt c s dng gia ng c v bin tn .

Insulation

Tools required lp t ACS550 bn cn nhng iu sau y : tua vt (thch hp cho lp t cc phn cng c s dng ) km tut dy bng keo khoang cho lp t lin quan n ACS550-U1, c khung R5 hoc R6 v IP54 / UL type 12 thng: khoang thng cho vic to l lp ng dn cho lp t lin quan n ACS550-U1, c khung R6: cng c g tm ph hp cho cp in . xem phn Power terminal considerations R6 frame size trn trang 269. lp t phn cng: inh vt hoc bu lng v inh c, mi loi 4. Cc loi phn cng ph thuc vo b mt gn kt v kch c khung
Frame size R1R4 R5 R6 Mounting hardware M5 M6 M8 #10 1/4 in 5/16 in

Suitable environment and enclosure Xc nhn rng cc mi ni m bo yu cu. ngn chn thit hi trc khi lp t, lu tr vn chuyn bin tn theo yu cu mi trng quy nh cho vic lu tr v vn chuyn. xem phn Ambient conditions trn trang 289.

Installation

ACS550 Users Manual

15

Xc nhn rng v my l ph hp, da trn v tr mc nhim : IP21 / UL loi 1 v: v tr phi c lp cho bi trong khng kh, kh c tnh n mn hoc cht lng, v cht dn gy nhim nh nc chy, ngng t , bi cacbon v cc ht kim loi . IP54 / UL type 12 enclosure: v ny cung cp khi bi trong khng kh v nh sng hoc nc phung t mi hng . nu , v mt s l do, mt bin tn IP21 cn c lp t m khng c hp che chn hoc bin tn IP54 khng c ng dn hoc tm che, xem lu trong chng Technical data, trang 292. Suitable mounting location Xc nhn rng v tr gn kt p ng cc rng buc sau y : Bin tn phi c gn theo chiu dc trn mt trn, rn, v trong mi trng thch hp nh mc nh trn . Cc yu cu khng gian ti thiu cho bin tn l kch thc bn ngoi (xem phn Outside dimensions trn trang 287), cng vi khng gian kh xung quanh bin tn (xem phn Cooling trn trang 283). Khong cch gia ng c v bin tn c gii hn bi chiu di ln nht cp ng c . xem phn Motor connection specifications trn trang 271. V tr lp t phi chp nhn trng lng bin tn. Xem phn Weight trn trang 288.

Installation

16

ACS550 Users Manual

Installing the drive


Cnh bo! Trc khi lp t ACS550, m bo u vo ngun in cung cp n bin tn l tt ,

Prepare the mounting location ACS550 ch nn c gn kt hp tt c cc yu cu quy nh trong phn Preparing for installation trn trang 12 c p ng. 1. nh du v tr ca cc l vi s gip ca mu cung cp vi bin tn 2. Khoang cc l. Ch : kch thc khung R3 v R4 c 4 l dc theo nh. Ch s dng 2. nu c th , s dng hai l bn ngoi ( cho php phng loi b qut cho bo tr ).
1
X0002

Ch : ACS400 bin tn c th c thay th bng cch s dng gn cc l ban u. Cho R1 v R2 kch c khung, lp t cc l ging ht nhau. Cho R3 v R4 kch c khung, bn trong cc l gn trn u ca bin tn ACS550 gn kt ph hp ACS400 .

Remove the front cover IP21 / UL type 1 1. G b bng iu khin , nu km theo . 2. Ni lng cc c vt trn u bin tn . 3. Ko gn u bn trn tho v .
1 2 3

IP2000

Installation

ACS550 Users Manual

17
R1R5

IP54 / UL type 12 1. nu c np che: tho vt (2) gi np che ti ch. 2. nu c np che: trt np che ln v g np. 3. ni lng vt xung quanh mp ca np. 4. tho v .

R6

1 1 2

4
FM

Mount the drive IP21 / UL type 1 1. v tr cc vt gn ACS550 hoc bu lng v an ton gn cht tt c bn gc . Ch : nht ACS550 bi khung kim loi ca n (kch c khung R6 bi cc l nng hai bn ). 2. khng phi l ting anh: thm mt nhn dn cnh bo trong ngn ng thch hp trn cnh bo trn u ca module. IP54 / UL type 12

IP2002

i vi IP54 / UL loi 12 thng, phch cm cao su c yu cu trong ch cung cp gn vo khe cm bin tn. 1. yu cu cho ng dn, g b phch cm cao su nhn phch cm ra pha sau bin tn . 2. R5 & R6: t vo v tr bng kim loi np (khng hin th) pha trc trn u bin tn. (nh km nh mt phn ca bc tip theo .) 3. nh v ACS550 vo gn cc c hoc bu lng v m bo an ton tht cht c 4 gc .
5 3

1, 4

Ch : nht ACS550 bi khung kim loi (kch c khung R6 ca l nng c hai bn pha trn ). 4. gn li cm cao su . 5. khng phi l ting anh: thm mt nhn dn cnh bo trong ngn ng thch hp cnh bo hin trn n ca module.
FM

Installation

18

ACS550 Users Manual

Wiring overview Conduit/Gland kit Dy dn bin tn vi IP21 / UL loi 1 enclosure i hi ng dn/np bt vi cc mc sau y : conduit/gland box five (5) cable clamps (ACS550-01 only) screws cover. B cng c ny bao gm vi IP21 / UL kiu 1 enclosures. Wiring requirements Cnh bo ! m bo ng c tng thch vi ACS550 ny . Bin tn phi c lp t bi mt ngi c thm quyn ph hp vi quy nh trong phn Preparing for installation trn trang 12. nu nghi ng , lin h vi i din bn hng hoc vn phng ABB ca bn . Khi bn lp t h thng in , quan st nhng iu sau y : c 4 thit lp ca h thng dy in mt thit lp cho mi h thng ca loi v bin tn (IP21 / UL v loi IP54 / UL type 12) v dy dn loi (ng dn hoc cp). Hy chc chc chn chn bin php ph hp . xc nh yu cu in t ph hp (EMC) cho m s cc b . Xem phn Motor cable requirements for CE & C-Tick compliance trn trang 274. Ni chung : tun th lut a phng cho kch thc cp . gi 4 lp ca h thng dy in tch ri : dy in u vo, dy ng c , dy iu khin/dy truyn thng v dy n v thng . khi lp t ngun in u vo v dy ng c, tham kho sau y cho ph hp :
Terminal U1, V1, W11 PE U2, V2, W2
1

M t 3-pha u vo ngun cung cp Bo v ni t Ngun in u ra n ng c

Thng s k tut v ch Input power connections trn trang 263 Ground connections trn trang 266 Motor connections trn trang 271

ACS550 -x1-xxxx-2 (208240 V series) c th s dng vi ngun cung cp 1 pha nu u ra dng in l gim ti 50%. Cho 1 pha in p cung cp, kt ni ngun in ti U1 v W1.

v tr u vo ngun in v u ni kt ni ng c, xem phn Power connection diagrams trn trang 20. i vi chi tit k thut v thit b u cui, xem phn Drives power connection terminals trn trang 268. i vi h thng ni t TN, xem phn Corner grounded TN systems trn trang 267. i vi h thng IT, xem phn IT systems trn trang 268.

Installation

ACS550 Users Manual

19

i vi kch thc khung R6, xem phn Power terminal considerations R6 frame size trn trang 269 lp t u dy cp cho ph hp . i vi bin tn s dng phanh (ty chn), tham chiu n sau y, cho tng thch:
Frame size R1, R2 R3, R4, R5, R6 Terminal BRK+, BRKUDC+, UDCDescription Braking resistor DC bus Braking accessory in tr phanh. Xem phn Brake components trn trang 277. Lin h vi i din ABB ca bn t hng hoc l : phanh n v hoc thng in v in tr

khi lp t h thng dy in , tham kho chng sau hoc phn, cho tng thch : Control terminals table trn trang 22 Control connections trn trang 281 Application macros trn trang 71 Complete parameter descriptions trn trang 98 Embedded fieldbus trn trang 189 Fieldbus adapter trn trang 221.

Installation

20

ACS550 Users Manual

Power connection diagrams S di y cho thy cch b tr thit b u cui cho kch c khung R3, vi, ni chung, p dng cho kch thc khung R1R6, ngoi tr R5/R6 u ni ngun in v ni t.
J1 DIP chuyn mch cho u vo tng t (hai loi c th c s dng) J1 J1 S cho thy khung R3 . ON AI1: ( v tr in p) khung khc c b tr tng t . 12 ON ON AI2: ( v tr dng in) kt ni bng iu khin X1 u vo v u ra tng t (v 10 V ref. in p u ra) Ty chn FlashDrop Power LED (xanh) Fault LED () X1 u ra relay

X1 u vo s
(v 24 V aux. in p u ra)

J2 DIP chuyn i cho RS485 termination J2 J2


ON ON

Ty chn module 1 X1 truyn thng (RS485)

Ty chn module 2 Bt v tr

Tc v tr

kch c khung R5/R6 khc . xem trang tip theo.

Ngun in u vo (U1, V1, W1)

Ngun in u ra n ng c (U2, V2, W2) EM3

EM1 GND PE
3AUA0000001571

Optional braking Frame size R1, R2 R3, R4 Terminal labels BRK+, BRK UDC+, UDCBrake options - phanh in tr phanh n v thng in v in tr

Cnh bo! i vi h thng IT v h thng ni t gc TN , ngt kt ni b lc EMC bn trong bng cch g b : - Trn ACS550-01: vt EM1 v EM3 - Trn ACS550-U1: vt EM1 (bin tn c vn chuyn vi EM3 c g b). xem IT systems trn trang 268 v Corner grounded TN systems trn trang 267.

Installation

ACS550 Users Manual

21

S di y cho thy b tr ngun in v ni t cho kch c khung R5 v R6


R5 R6

F2

F1

F2

PE
X0011

GND GND

ngun in u vo (U1, V1, W1)

Ngun in u ra n ng c (U2, V2, W2) F1

Ty chn phanh Frame size R5, R6 Terminal labels UDC+, UDCBrake options phanh n v thng in v in tr

PE ngun in u vo (U1, V1, W1)

GND

X0013

Ngun in u ra n ng c (U2, V2, W2)

Cnh bo ! i vi h thng IT v h thng ni t gc TN , ngt kt ni b lc EMC bn trong bi g b F1 v F2. xem IT systems trn trang 268 v Corner grounded TN systems trn trang 267.

Installation

22

ACS550 Users Manual

Control terminals table Sau y cung cp thng tin cho kt ni dy iu khin X1 trn bin tn.
X1 1 2 SCR AI1 Hardware description u ni cho tn hiu cp l chn. (kt ni bn trong n khung ni t.) u vo knh 1, lp trnh. Mc nh 2 = tn s tham chiu. phn gii 0.1%, chnh xc 1%. Hai loi cng tc DIP c th c s dng J1: AI1 OFF: 010 V (Ri = 312 kohm) Analog I/O 3 4 5 AGND +10 V AI2 J1: AI1 ON: 020 mA (Ri = 100 ohm)
ON ON

1 1

ON ON

u vo tng t dng in chung (kt ni bn trong n sn gnd. Thng qua 1 Mohm). in th ngun tham chiu : 10 V 2%, max. 10 mA (1 kohm < R < 10 kohm). u vo tng t knh 2, lp trnh. Mc nh 2 = khng s dng. phn gii 0.1%, chnh xc 1%. Hai loi cng tc DIP c th c s dng . J1: AI2 OFF: 010 V (Ri = 312 kohm) J1: AI2 ON: 020 mA (Ri = 100 ohm)
ON ON

1 1

ON ON

6 7 8 9 10 11

AGND AO1 AO2 AGND +24V GND

u vo tng t dng in chung (kt ni bn trong n sn gnd. Thng qua 1 Mohm). u ra tng t, lp trnh. Mc nh 2= tn s. 020 mA (ti < 500 ohm). chnh xc 3%. u ra tng t, lp trnh. Mc nh 2= dng in. 020 mA (ti < 500 ohm). chnh xc 3%. u ra tng t dng in chung (kt ni bn trong n sn gnd. Thng qua 1 Mohm). u ra in p ph 24 V DC / 250 mA (tham chiu n GND), bo v ngn mch dng in . u ra in p ph chung (kt ni bn trong l th ni ). u vo s chung. kch hot u vo s, phi c +10 V (hoc -10 V) gia u vo v DCOM. 24 V c cung cp bi ACS550 (X1-10) hoc bi mt ngun bn ngoi 1224 V ca khng phn cc. u vo s 1, lp trnh. Mc nh 2 = start/stop. u vo s 2, lp trnh. Mc nh 2 = fwd/rev. u vo s 3, lp trnh. Mc nh 2 = hng s tc sel (m). u vo s 4, lp trnh. Mc nh 2 = hng s tc sel (m). u vo s 5, lp trnh. Mc nh 2 = chn cp dc (m). u vo s 6, lp trnh. Mc nh 2 = khng s dng.

12 DCOM Digital inputs1 13 14 15 16 17 18

DI1 DI2 DI3 DI4 DI5 DI6

Installation

ACS550 Users Manual

23

X1 19 20 21 Relay 22 outputs 23 24 25 26 27
1 2

Hardware description u ra relay 1, lp trnh. Mc nh = sn sng Ln nht: 250 V AC / 30 V DC, 2 A Nh nht: 500 mW (12 V, 10 mA) u ra relay 2, lp trnh. Mc nh = chy Ln nht: 250 V AC / 30 V DC, 2 A Nh nht: 500 mW (12 V, 10 mA) u ra relay 3, lp trnh. Mc nh = li (-1) Ln nht: 250 V AC / 30 V DC, 2 A Nh nht: 500 mW (12 V, 10 mA)

RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

u vo s tr khng ti a 1.5 kohm in p u vo s l 30 V. Gi tr mc nh ph thuc vo s dng macro . Gi tr c xc lp cho macro mc nh. Xem chng Application macros trn trang 71.

Ch : Terminals 3, 6 v 9 l ang cng in th .

Ch : v l do an ton tn hiu relay l li khi ACS550 ngun nui xung .

Cnh bo ! All ELV (Extra Low Voltage) mch kt ni n bin tn phi c s dng trong khu vc ca lin kt ng th, tc l trong khu vc ni tt c b phn dn in tng thch vi nhau c kt ni in ngn in p nguy him xut hin gia chng . iu ny c thc hin bi mt my ni t thch hp . Cc u ni trn board iu khin cng nh trn ty chn modules gn km board thc hin Protective Extra Low Voltage (PELV) yu cu c bit trong EN 50178, vi iu kin l mch bn ngoi kt ni n u ni cng thc hin cc yu cu v v v tr lp t l di 2000 m (6562 ft) Bn c th ni dy dn u vo s u ni khc cu hnh PNP hoc NPN.
PNP connection (source) X1 10 11 12 13 14 15 16 17 18 +24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 NPN connection (sink) X1 10 11 12 13 14 15 16 17 18 +24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6

Installation

24

ACS550 Users Manual

Install the wiring Kim tra kt ni ng c v cp ng c . Cnh bo ! kim tra lp t ng c v cp ng c trc khi kt ni bin tn n u vo ngun in. i vi kim tra ny, chc chn rng cp ng c l khng kt ni n bin tn . 1. hon thnh kt ni cp ng c n ng c, nhng khng n ng ra u ni (U2, V2, W2) ca bin tn . 2. cui bin tn ca cp ng c, o in tr cch in gia mi pha cp ng c v bo v ni t (PE): p dng in p ca 1 kV DC v xc minh rng in tr ln hn 1 Mohm.

M ohm PE

Installation

ACS550 Users Manual

25

Wiring IP21 / UL type 1 enclosure with cables 1. m tho ra tng ng trong ng dn/ming m hp . (xem phn Conduit/Gland kit trn trang 18.) 2. lp t kp cp cho cp ngun /cp ng c . 3. trn dy v cp in u vo, tc b v bc n v tr ny gn cp ring l. 4. trn cp ng c, tc b v bc xa l dy dn ng c th xon li thnh ui . gi ui xon ngn gim nh ting n pht x 360 ni t di bu lng sit c khuyn khch cho cp ng c gim ting n bc x. trong trng hp ny, g b v bc ti kp cp. 5. tuyn cp thng qua c hai kp mc . 6. bng keo v kt ni dy ngun /dy ng c v dy in ngun ni t n u ni bin tn . Ch : cho kch c khung R5, kch c cp ngun ti thiu l 25 mm2 (4 AWG). cho kch c khung R6 , tham kho n phn Power terminal considerations R6 frame size trn trang 269. 7. kt ni to thnh u ni dy mm t cp ng c n u ni GND. 8. lp ng dn/ming m hp v sit cht kp cp . 9. lp kp cp (s) cho cp iu khin (s). (cp ngun in/cp ng c v sit cht khng c th hin trong con s ) 10. qun bng keo cp iu khin v sit c ng vo trong u ni dy mm. 11. ng cp iu khin (s) thng qua kp (s) v sit cht kp (s). 12. kt ni li lc vi t u ni dy mm cho cp s v tng t I/O ti X1-1. (ch ni t cui bin tn ) 13. kt ni li lc vi t u ni dy mm cho cp RS485 ti X1-28 hoc X1-32. (ch ni t cui bin tn.) 14. qun bng keo v kt ni cc u dy iu khin n u ni bin tn. Xem phn Control terminals table trn trang 22. 15. lp t ng dn/ming m hp bao gm (1 vt ).
IP2003 X0005

2 1 6 7 6 3 8 4
X0004

IP2001

9
X0006

12 14

11

Installation

26

ACS550 Users Manual

Wiring IP21 / UL type 1 enclosure with conduit 1. m tho ra tng ng trong ng dn/ming m hp. (xem phn Conduit/Gland kit trn trang 18.) 2. lp t ming kp mng ng dn (khng cung cp).

X0007

3. lp t ng dn/ming m hp. 4. kt ni ng dn chy vo hp.


3

X0005

5. trn u dy ngun v dy ng c thng qua ng dn (phi chy ring ng dn ). 6. bng keo ng dn . 7. kt ni dy ngun in, ng c v ni t n u ni bin tn. Ch : i vi kch c khung R5, kch thc cp ngun ti thiu l 25 mm2 (4 AWG).
7

5 4
IP2004

i vi kch c khung R6, tham kho n phn Power terminal considerations R6 frame size trn trang 269. 8. ng truyn cp iu khin thng qua ng dn (phi c tch bit vi u vo ngun in v ng dn chy ng c). 9. qun bng keo cp iu khin v sit cht b lc vo trong u ni dy mm. 10. kt ni ni t b lc u ni dy mm cho cp s v tng t I/O ti X1-1. (ch ni t ti im cui bin tn.) 11. kt ni ni t b lc u ni dy mm cho cp RS485 ti X1-28 hoc X1-32. (ch ni t ti im cui bin tn.) 12. qun bng keo v kt ni dy iu khin ring bit n u ni bin tn. xem phn Control terminals table trn trang 22. 13. lp t ng dn/ming m hp bao gm (1 vt ).
IP2005

10 12

Installation

ACS550 Users Manual

27

Wiring IP54 / UL type 12 enclosure with cables 1. ct cp bch kn l cn thit cho cp ngun in , cp ng c v cp iu khin. (bch kn cp l hnh nn, c bch cao su trn di ca bin tn .)

IP5003

2. trn u vo cp ngun , tc v bc tr li xa truyn ng dy ring bit . 3. trn cp ng c, tc v bc tr li xa l ra dy ng b lc xon b lc thnh mt u ni dy mm. gi u ni dy mm ngn gim ting n bc x . 360 ni t di bu lng sit c khuyn khch cho cp ng c gim ting n bc x. Trong trng hp ny, g b v bc ti kp cp . . 4. ng truyn cp thng qua hai kp v sit cht ci kp .

5 2 4

3 4

IP5004

5. qun bng keo v kt ni dy ngun/dy ng c v dy ngun ni t n u ni bin tn . . Ch : i vi kch c khung R5, kch c cp ngun nh nht l 25 mm2 (4 AWG). i vi kch c khung R6, tham kho n phn Power terminal considerations R6 frame size trn trang 269. 6. kt ni u ni dy mm to ra t b lc cp ng c n u ni GND . 7. bng keo v bc cp iu khin v xon cp ng vo u ni dy mm. 8. ng truyn cp iu khin(s) kp cp(s) v sit cht kp cp (s). 9. kt ni b lc ni t u ni dy mm cho cp I/O s v tng t X1-1. (ch ni t im cui bin tn .) 10. kt ni ui b lc ni t u ni dy mm cho cp RS485 ti X1-28 hoc X1-32. (ch ni t im cui bin tn .) 11. bng keo v kt ni dy iu khin ring bit n u ni bin tn. Xem phn Control terminals table trn trang 22.

911

IP5005

Installation

28

ACS550 Users Manual

Wiring IP54 / UL type 12 enclosure with conduit 1. ph thuc vo kch thc khung : R1R4: g b v lai b bt cp ni ng ng s c t. (cc bt cp hnh nn , bt cao su trn di cng ca bin tn )
1 R5, R6 1
IP5013

R1R4

R5 v R6: dng my khoang to cc l cho kt ni ng dn khi cn thit .

2. i vi mi ng dn chy, lp t kt ni ng dn chng nc (khng cung cp ).


2

IP5023

3. truyn dy ngun in thng qua ng dn. 4. truyn dy ng c thng qua ng dn . 5. bng keo cc dy . 6. kt ni dy ngun in, ng c v ni t n u ni bin tn . Ch : i vi kch thc khung R5, kch thc cp ngun nh nht l 25 mm (4 AWG).
6

IP5016

4
IP5007

i vi kch thc khung R6, tham kho n phn Power terminal considerations R6 frame size trn trang 269. 7. truyn cp thng qua ng dn . 8. bng keo v bc cp iu khin v xon cp ng vo trong pig-tail. 9. kt ni b lc ni t u ni dy mm cho cp I/O s v tng t X1-1. (ch ni t im cui bin.) 10. kt ni b lc ni t u ni dy mm cho cp RS485 X1-28 hoc X1-32. (ch ni t im cui bin.) 11. bng keo v kt ni dy iu khin ring bit n cc u ni bin tn. Xem phn Control terminals table trn trang 22.

Installation

ACS550 Users Manual

29

Check installation Trc khi cp ngun, thc thin cc kim tra sau .
Check Mi trng lp t ph hp vi yu cu k thut ca bin tn cho iu kin mi trng . Bin tn c gn mt cch an ton . Khng gian xung quanh bin tn t im k thut lm mt . ng c v thit b iu khin sn sng khi ng . i vi h thng IT v h thng ni t gc TN: ngt kt ni b lc EMC (c EM1 & EM3 hoc g b F1 & F2 ). Bin tn l ni t thc s . in p ngun u vo (chnh) ph hp u vo in p danh nh bin tn . u vo ngun in (chnh) kt ni ti U1, V1 v W1 c kt ni v sit cht theo quy nh. Ngun in u vo (chnh) cu ch c lp t . ng c c kt ni ti U2, V2 v W2 c kt ni v sit cht theo quy nh . Cp ng c l lun lun truyn loi cp khc . Khng c h s cng sut b t in trong cp ng c. Kt ni iu khin c kt ni v sit cht theo quy nh. Khng cng c hoc i tng bn ngoi (chn hn nh mnh vn khoang) l bn trong bin tn. Khng cu ngun in thay th cho ng c (chn hn nh b qua kt ni) c kt ni khng in p c p dng n u ra ca bin tn .

Installation

30

ACS550 Users Manual

Reinstall the cover IP21 / UL type 1 1. t v vo v tr v lp mng trc ca n vo . 2. sit cht cc vt gi li . 3. lp t bng iu khin . 4. tip tc vi start up. Xem chng Start-up, control with I/O and ID Run trn trang 31. 3 2 1

IP2009

IP54 / UL type 12

R6 4 4

R1R5

1. t v vo v tr v lp mng trc ca n vo . 2. sit cht cc vt quanh vin ca v . . 3. trc np xung trn u ca v. (ch cn thit lp t cho UL kiu 12.) 4. lp t hai c nh km trn np (ch cn thit lp t cho UL kiu 12 .) 5. lp t bng iu khin. Ch : ca s bng iu khin phi c ng thc hin theo IP54 / UL kiu 12. 1 2
FM

5 6

6. ty chn: thm mt kha (khng cung cp) m bo cho ca s bng iu khin. 7. tip tc vi start-up. Xem chng Start-up, control with I/O and ID Run trn trang 31.

Installation

ACS550 Users Manual

31

Khi ng, iu khin vi I/O v ID run


Chng ny hng dn lm th no :
Thc hin khi ng . Khi ng , dng li, thay i hng quay v iu chnh tc ng c

thng qua giao din I/O


thc hin chy xc nh cho bin tn (ID RUN).

S dng bng iu khin lm nhng cng vic ny c gii thch ngn gn trong chng ny. bit chi tit v cch s dng bng iu khin, hy tham kho chng Control panel bt u t trang 41.

Lm th no khi ng bin tn
Lm th no bn khi ng bin tn t bng iu khin bn c,
Nu bn c mt bng iu khin h tr, bn c th thc hin cc h tr khi ng

(xem mc Lm th no thc hin hng dn khi ng trn trang 36 ) hoc thc hin hn ch khi ng (xem mc Lm th no thc hin hn ch khi ng trn trang 31 ). Cc h tr khi ng, bao gm trong bng iu khin h tr duy nht, hng dn bn qua tt c cc thit lp cn thit phi lm. Trong gii hn khi ng, bin tn khng a ra hng dn, bn i qua cc thit lp rt c bn bng cch lm theo hng dn trong sch hng dn.

Nu bn c mt bng iu khin c bn, thc hin theo cc hng dn trong phn Lm

th no thc hin hn ch khi ng trn trang 31

Lm sao thc hin hn ch khi ng hn ch khi ng, bn c th s dng bng iu khin c bn hay bng iu khin h tr .nhng ch dn di ph hp c hai bng iu khin, nhng mn hnh hin th l mn hnh bng iu khin c bn tr khi ch th ny p dng cho duy nht bng iu khin h tr . Trc khi bn khi ng, m bo rng bn c bng d liu thng s ng c trn tay.

AN TON
Vic khi ng ch c th c thc hin bi mt th in iu kin. Cc hng dn an ton trong chng an ton phi c tun theo trong thi gian bt u qu trnh khi ng. Bin tn s t ng khi ng lc cp ngun nu c lnh chy bn ngoi.

Kim tra vic ci t. Xem danh sch kim tra trong chng danh sch kim tra ci t trn trang 29.

Start-up, control with I/O and ID Run

32

ACS550 Users Manual

Kim tra xem s khi ng ca ng c khng gy bt k nguy him no. Tch ri truyn ng my nu: C nguy c thit hi trong trng hp khng ng hng t quay, hay
Mt ID RUN cn phi c thc hin trong khi bin tn khi ng. ID Run l cn thit ch trong ng dng yu cu chnh xc cui cng trong iu khin ng c.

CP NGUN Cp ngun vo. Bng iu khin c bn i n ch u ra.


REM OUTPUT

00 .

Hz

FWD

Bng iu khin h tr hi bn c mun thc hin h tr khi - REM CHOICE Do you want to khi ng. Nu bn nhn EXIT , Start-up Assistant khng thc use the start-up assistant? hin, v bn c th tip tc vi hng dn khi ng ging Yes No theo cch thc c m t di y cho bng iu khin c EXIT 00:00 bn . HNG DN NHP D LIU KHI NG (nhm 99: START-UP DATA) Nu bn c bng iu khin h tr, chn ngn ng (bng iu khin c bn khng h tr ngn ng). Xem tham s 9901 cho cc ngn ng c sn la chn thay th . Bn tm thy m t trong phn tham s Complete parameter descriptions bt u t trang 98. Th tc thit lp cc thng s chung c m t bng di y cho bng iu khin c bn trn trang 67.Bn tm thy hng dn chi tit cho bng iu khin h tr trn trang 49. Tham s thit lp th tc chung:
1. i ti menu chnh nhn
REM

OK

PAR EDIT

9901 LANGUAGE [0] CANCEL 00:00

ENGLISH
SAVE

REM

nu khng nhn
2. . Nhn phm

nu dng di cng thy OUTPUT; cho ti khi bn nhn thy MENU pha di. ti khi thy PAr v nhn
.
REM

MENU

rEF -01PAR PAR

FWD

FWD

3. Tm kim tham s thch hp trong nhm bi phm .

v nhn

REM

2001 2002
PAR

FWD

4. Tm thy tham s thch hp trong nhm bi phm nhn

REM

FWD

5. Nhn v gi

hin th vi

SET

khong 2 giy khi gi tr thng s pha di gi tr.

REM

1500 1600
PAR

rpm

PAR SET FWD

6. Thay i gi tr vi phm

trong khi ban gi phm bm .

. Thay i thng s nhanh hn

REM

rpm

PAR SET FWD

7. Lu

gi tri tham s bi nhn

REM

2002

FWD

Start-up, control with I/O and ID Run

ACS550 Users Manual

33

Chn ng dng macro (tham s 9902). Cc thng s trong qu trnh ci t chung l chn cao hn cho.
Gi tr mc nh 1 (ABB STANDARD) l thch hp trong a s trng hp.

REM

9902
PAR

FWD

Chn cch iu khin ng c (tham s 9904).


hp cho ng dng iu khin momen xon . 3 (SCALAR:FREQ)c ngh
Bin tn s dng cho nhiu ng c, khi s lng ng c kt ni n bin

REM

1 (VECTOR:SPEED) l ph hp trong nhiu trng hp. 2 (VECTOR:TORQ) l ph

9904
PAR

FWD

tn l thay i
Khi dng in danh nh ca ng c thp hn 20% so vi dng in

danh nh ca bin tn
Khi bin tn c s dng cho mc ch th nghim khng c kt ni vi ng c.

D lu vo ng c t bng thng s ng c: ABB Motors


3 motor M2AA 200 MLA 4 IEC 200 M/L 55 No Ins.cl. F V 690 Y 400 D 660 Y 380 D 415 D 440 D Cat. no 6312/C3 Hz 50 50 50 50 50 60 kW 30 30 30 30 r/min 1475 1475 1470 1470 1475 cos 32.5 0.83 56 0.83 34 59 54 59 0.83 0.83 0.83 0.83 A IP 55 IA/IN t E/s

Ch : Thit lp d liu cho ng c chnh xc nh gi tr trn bng thng s ng c.i vi v d, nu tc danh nh ng c l 1470 rpm trn bng thng s, ci t gi tr ca tham s 9908 MOTOR NOM SPEED kt qu n 1500 rpm trong hot ng sai ca bin tn.

30 35 1770

380 V in p cung cp

3GAA 202 001 - ADA 6210/C3 IEC 34-1 180

in p danh nh ng c (tham s 9905)

REM

9905
PAR

FWD

Dng in danh nh ng c (tham s 9906)


Phm vi cho php: 0.22.0 I2hd A

REM

9906
PAR

FWD

Tn s danh nh ng c (tham s 9907)

REM

9907
PAR

FWD

Tc danh nh ng c (tham s 9908)

REM

9908
PAR

FWD

Cng sut danh nh ng c (tham s 9909)

REM

9909
PAR

FWD

Start-up, control with I/O and ID Run

34

ACS550 Users Manual

Chn phng php nhn dng (tham s 9910). Gi tr mc nh 0 (OFF/IDMAGN) s dng s nhn bit t ha l tin dng nn s dng n l tt nht. Nn p dng qu trnh hot ng c bn ny. Tuy nhin lu rng iu ny: Tham s 9904 c thit lp 1 (VECTOR: SPEED) hoc 2 (VECTOR: TORQ) hoc Tham s 9904 c thit lp 3 (SCALAR: FREQ), v tham s 2101 c thit lp 3 (SCALAR FLYSTART) hoc 5 (FLY + BOOST). Nu bn chn l 0 (OFF/IDMAGN), di chuyn sang bc tip theo. Gi tr 1 (ON) nn c chn nu: ch iu khin vector c s dng [tham s 9904 = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ)],v/hoc im hot ng c tc gn bng khng ,v/hoc Phm vi hot ng ca m-men xon trn m-men xon danh nh ca ng c c tc v phm vi rng m khng c bt k phn hi tc no c yu cu. Nu bn quyt nh chn ID Run (gi tr 1 (ON)), tip tuc bng cch lm theo cc hng dn a ra trn trang 39 trong phn Lm th no thc hin ID RUN v sao quay v bc Hng quay ca ng c trn trang 34. XC NH T TNH VI CHN HOAT NG ID 0 (OFF)
Nh nu trn, nhn dng t tnh ch c thc hin nu: tham s 9904 thit lp n 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ), hoc tham s 9904 thit lp n 3 (SCALAR:FREQ ) v tham s 2101 thit lp n 3 (SCALAR FLYST) hoc 5 (FLY + BOOST). Nhn phm LOC REM chuyn i n kim sot cc b (LOC hin th trn pha tri). Nhn khi ng bin tn. cc m hnh ng c hin nay c tnh bng cch t ha ng c cho 10 n 15 giy tc khng (ng c khng xoay).

HNG QUAY CA NG C Kim tra hng quay ca ng c.


Nu bin tn ch iu khin t xa (REM pha trn bn tri), chuyn sang kim sot cc b bi nhn LOC . REM i n menu chnh , nhn
LOC

nu dng di cng cho

xxx .

Hz

SET FWD

thy OUTPUT; nu khng nhn lin tc cho ti khi bn thy MENU pha di. / . Nhn phm n khi bn thy rEF v nhn
Tng tn s tham chiu t khng n mt gi tr nh . vi phm

hot ng ng c. Kim tra xem hng quay thc t ca ng c c ging nh chiu c hin th trong mn hnh khng(FWD c ngha l quay thun v REV l quay nghch). dng ng c. Nhn
Nhn

Start-up, control with I/O and ID Run

ACS550 Users Manual

35

Thay i chiu quay ca ng c:


Ngt kt ni u vo ngun in t bin tn v ch 5 pht cho

t in mch trung gian x ht in . o in p u vo mi thit b u cui (U1,V1v W1) vi mt bng ng h o vn nng m bo rng bin tn x ht in .
Thay i v tr ca 2 dy ngun ra ng c ti ng xut ra ca bin tn hay ti hp kt ni ca ng c. Xc nhn cng vic ca bn bng cch cp ngun vo v lp li kim tra nh trn.

forward direction

reverse direction

GII HN TC V THI GIAN TNG TC / THI GIAN GIM TC t tc nh nht (tham s 2001).
LOC

2001
PAR

FWD

t tc ln nht (tham s 2002).

LOC

2002
PAR

FWD

t thi gian tng tc 1 (tham s 2202). Ch : Cn kim tra thi gian tng tc 2 (tham s 2205) nu 2 thi gian tng tc s c s dng trong ng dng. t thi gian gim tc 1 (tham s 2203). Ch : cn t thi gian gim tc 2 (tham s 2206) nu 2 thi gian gim tc s c s dng trong ng dng.

LOC

2202
PAR

FWD

LOC

2203
PAR

FWD

LU LI S DNG MT MACRO V KIM TRA CUI CNG iu kin khi ng by gi c b sung. Tuy nhin, n c ch ti giai on ny ci t cc yu cu ca ng dng v lu cc ci t s dng tham s theo hng dn trong phn User macros trn trang 81. Kim tra xem tnh trng bin tn l OK. Basic Control Panel: kim tra rng khng c li hoc bo ng hin th trn mng hnh. Nu bn mun kim tra cc n LED trn mt trc bin tn, bt cng tc iu khin t xa (mt li c to ra) trc khi loi b cc bng v chng minh cc LED khng sng v LED xanh sng nhng khng nhy. Assistant Control Panel: kim tra xem c li hay khng hoc bo ng hin trn mn hnh v bng iu khin LED mu xanh v khng nhp nhy. Bin tn sn sng s dng.
LOC

9902
PAR

FWD

Start-up, control with I/O and ID Run

36

ACS550 Users Manual

Lm th no thc hin hng dn khi ng c th thc hin hng dn khi ng, bn cn c Assistant Control Panel trc khi khi ng, m bo rng bn c d liu ca ng c trn tay . AN TON Vic khi ng ch c th c thc hin bi mt th in iu kin. Cc hng dn an ton trong chng trnh an ton c phi tun theo trong thi gian khi ng. Bin tn s t ng khi ng nu c lnh chy bn ngoi. Kim tra vic ci t. Xem danh sch kim tra trong danh sch kim tra ci t chng trn trang 29. Kim tra xem s khi ng ca ng c m bo khng gy bt k s nguy him no.
Tch ri truyn ng my nu :
S iu khin b li hp ca ng c c mt nguy c thit hi trong trng hp khng ng hng . ID run cn phi c thc hin trong lc khi ng bin tn .ID run cn thit trong ng dng yu cu chnh xc cui cng trong iu khin ng c.

NGUN Cp ngun vo .u tin bng iu khin s hi bn mun s dng Start-up Assistant. Nhn OK (khi Yes sng ln) chy khi ng
Assistant. Nhn
EXIT

nu bn khng mun chy cc khi ng tr gip..

REM CHOICE Do you want to use the start-up assistant? Yes No EXIT 00:00

OK

Nhn phm

im sng No v sau nhn OK nu bn mun lm bng hi (hoc khng hi) cc cu hi v chy tr gip khi ng ln sau khi bn bt cng tc ngun cho bin tn .
.

REM CHOICE Show start-up assistant on next boot? Yes No EXIT 00:00

OK

CHN NGN NG
Nu bn quyt nh chy cc Start-up Assistant, sau mn hnh yu cu bn chn ngn ng. Di chuyn n ngn ng bn mun . / v nhn SAVE chp nhn. Nhn
REM PAR EDIT 9901 LANGUAGE [0] EXIT

ENGLISH
00:00 SAVE

Nu nhn

EXIT

, Start-up Assistant b ngng li.

HNG DN CI T KHI NG
Start-up Assistant hin ti hng dn bn thng qua ci t nhim,
REM PAR EDIT

v,khi ng vi ci t ng c. t d liu ng c chnh xc cng gi tr nh trn bng thng s ng c.


/ v Di chuyn n gi tr tham s vi phm Nhn SAVE chp nhn v tip tc vi cc Start-up Assistant

9905 MOTOR NOM VOLT

220 V
00:00

EXIT

SAVE

Ch : ti bt k lc no, nu bn nhn EXIT Start-up Assistant dng li v mng hnh i vo ch u ra.

Start-up, control with I/O and ID Run

ACS550 Users Manual

37

Sau khi hon thnh nhim v ci t, Start-up Assistant cho thy k tip. Nhn OK (khi Continue is sng ln) tip tc xut nhim v. n sng ln Skip v sau nhn OK chuyn Nhn phm sang nhim v sau m khng lm nhim v xut. Nhn EXIT dng the Start-up Assistant. LU S DNG MACRO V KIM TRA CUI CNG Vic khi ng hon thnh. Tuy nhin, n c th c ch giai on ny t cc thng s yu cu bi ng dng ca bn v lu li cc ci t ng dng macro theo hng dn User parameter sets trn trang 81. Sau khi ton b ci t l hon tt , kim tra khng c li hoc bo ng c hin th trn mang hnh v bng iu khin LED mu xanh l v khng nhp nhy. Bin tn sn sng s dng.

REM CHOICE Do you want to continue with application setup? Continue Skip EXIT 00:00

OK

Start-up, control with I/O and ID Run

38

ACS550 Users Manual

Lm th no kim sot bin tn thng qua giao din vo /ra


Bng di y hng dn lm th no khi ng ng c thng qua tnh hiu s v tn hiu tng t u vo khi :
Thc hin khi ng ng c, v Mc nh (tiu chun) tham s ci t hp l.

Mng hnh hin th ca Basic Control Panel c hin th nh l mt v d. CI T S B Nu bn cn thay i hng t quay, kim tra xem tham s 1003 ci t l 3 (REQUEST). m bo rng cc kt ni dy theo s kt ni c cho bi ABB Standard macro.
REM m bo rng bin tn ang ch iu khin t xa.nhn phm LOC

Xem phn ABB Standard macro trn trang 72. Trong ch t xa, bng iu khin cho thy hin th REM.

chuyn i gia ch t xa v cc b KHI NG V KIM SOT TC NG C Khi ng khi c tn hiu s u vo DI1 on. Assistant Control Panel: mi tn bt u xoay. Cho n khi t im t. Basic Control Panel: k t FWD bt u nhp nhy nhanh v dng li khi t im t Thay i tn s u ra ca bin tn (tc ng c) bng cch iu chnh in p hoc dng in tn hiu u vo tng t AI(1).. THAY I CHIU QUAY NG C QUAY NGHCH: cng tc tn hiu s nhp vo DI2 on. QUAY THUN: cng tc tn hiu s nhp vo DI2 off.

REM OUTPUT

00 . 500 . 500 . 500 .

Hz

FWD

REM OUTPUT

Hz

FWD

REM OUTPUT

Hz REV

REM OUTPUT

Hz

FWD

DNG NG C Cng tc tn hiu s vo DI1 off. ng c dng.. Assistant Control Panel: mi tn ngng quay. Basic Control Panel: k t FWD bt u nhp nhy chm.
REM OUTPUT

00 .

Hz

FWD

Start-up, control with I/O and ID Run

ACS550 Users Manual

39

Lm th no thc hin ID RUN


Bin tn t ng c lng c tnh ca ng c khi bin tn hot ng ln u tin v sau khi bt k thng s ng c (nhm 99 START-UP DATA) c thay i. y l hp l khi tham s 9910 ID RUN c gi tr 0 (OFF/IDMAGN).v
tham s 9904 = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ), hoc

tham s 9904 = 3 (SCALAR:FREQ) v tham s 2101 = 3 (SCALAR FLYST) hoc 5 (FLY + BOOST). Trong hu ht cc ng dng khng cn phi thc hin mt RUN ID ring [9910 ID RUN = 1 (ON)]. ID Run nn c chn nu :
Hnh thc kim sot vector c s dng [tham s 9904 = 1 (VECTOR:SPEED) hoc

2 (VECTOR:TORQ)], v/hoc
im hot ng l tc gn bng khng v/ hoc Phm vi hot ng momen xon trn momen xon danh nh ca ng c, trn phm vi tc rng, v khng c bt k phn hi o tc (l khng c b encoder) c dng.

Ch : nu cc thng s ng c (nhm 99 START-UP DATA) c thay i sau khi cc ID Run, n phi c lp i lp li. Quy trnh ID Run Tham s ci t chung khng phi lp i lp li. Assistant Control
Panel xem trang 49 v cho Basic Control Panel trang 67 trong chng Control panels. PRE-CHECK

Cnh bo! ng c s chy ti khong 5080% ca tc danh nh trong khi Run ID. ng c s quay theo hng quay thun. m bo an ton chy ng c trc khi thc hin ID Run ! Khng ghp ng c vi cc thit b iu khin.
Kim tra xem gi tr ca d liu ng c cc tham s 99059909 tng ng vi bng thng s ng c nh hin th trong cc bc trn trang 33.

Nu gi tr tham s (chng 01 OPERATING DATA n chng 98 OPTIONS) c thay i trc khi ID Run, kim tra xem cc ci t mi c p ng cc iu kin sau :
2001 MINIMUM SPEED < 0 rpm

2002 MAXIMUM SPEED > 80% ca tc ng c cao nht 2003 MAXIMUM CURRENT > I2hd 2017 MAX TORQUE 1 > 50% hoc 2018 MAX TORQUE 2 > 50%, ty thuc vo gii hn c s dng theo tham s 2014 MAX TORQUE SEL.

Kim tra xem Run Enable l tnh hiu s (tham s 1601). m bo rng bng iu khin trong ch iu khin cc b (LOC hin th bn tri LOC n REM u trang). Nhn phm REM chuyn i gia iu khin cc b v iu khin t xa..
LOC

Start-up, control with I/O and ID Run

40

ACS550 Users Manual

ID RUN VI BNG IU KHIN PH Thay i tham s 9910 ID RUN n 1 (ON). Lu ci t mi bi nhn SAVE .
LOC PAR EDIT 9910 ID RUN [1] CANCEL

ON
SAVE 50.0Hz

00:00

Nu bn mun theo di gi tr thc t trong ID RUN, i n ng ra bng cch nhn EXIT lin tc cho ti bn tm c
.

LOC

DIR

0.0 Hz 0.0 A 0.0 %


00:00 ALARM

MENU

Nhn bt u ID Run . Bng iu khin gi cc chuyn i trn mng hnh hin th c hin th khi bn bt u ID RUN v hin th bo ng bn phi. Ni chung ,n khng ngh nhn bt k phm iu khin trong khi ID Run. Tuy nhin, bn c th dng ID Run ti bt c lc . no bng cch nhn Sau khi khi ng ID Run honh thnh , mn hnh hin th bo ng khng c hin th na.. Nu khi khi ng ID khng thnh cng , hin th li ny trn pha phi mng hnh hin th. ID RUN VI BNG IU KHIN C BN Thay i tham s 9910 ID RUN n 1 (ON). Lu ci t mi . bi nhn

LOC

ALARM 2019
ID run 00:00

LOC

FAULT

FAULT 11
ID RUN FAIL 00:00

LOC

9910
PAR

FWD

LOC

PAR SET FWD

Nu bn mun theo di cc gi tr thc t trong ID Run, i n ng ra bng cch nhn nhiu ln cho n khi bn nhn c. Nhn chy Run ID. Bng iu khin gi cc chuyn i gia mng hnh hin th c hin th khi bn chy cc ID Run v hin th bo ng bn ngoi. Ni chung ,n khng ngh nhn bt k phm iu khin trong khi ID Run.Tuy nhin, bn c th dng the ID Run ti bt c lc . no bng cch nhn Sau khi ID Run honh thnh , mn hnh hin th bo ng khng c hin th na. Nu khi khi ng ID Run khng thnh cng , hin th li ny trn pha phi mng hnh hin th.

LOC OUTPUT LOC

00 .

Hz

FWD

A2019 F0011

FWD

LOC

FWD

Start-up, control with I/O and ID Run

ACS550 Users Manual

41

Bng iu khin
Bng iu khin tch hp
S dng mt bng iu khin kim sot bin tn, c tnh trng d liu v iu chnh cc thng s. Bin tn lm vic vi mt trong hai loi bng iu khin khc nhau: Basic Control Panel bng ny (c m t trong phn Basic Control Panel trn trang 62) cung cp cng c c bn cho cc cm t hng dn s dng cc gi tr tham s
.
Assistant Control Panel bng ny (m t di y) bao gm cc trnh t lp trnh tr gip t ng thit lp cc thng s ph bin nht. Bng iu khin ny cng cung cp h tr ngn ng n c sn cc ngn ng khc nhau.

Kh nng tng thch


Hng dn s dng ny tng thch vi cc phin bn sau y :
Basic Control Panel: ACS-CP-C Rev. K Assistant Control Panel (Area 1): ACS-CP-A Rev. Y Assistant Control Panel (Area 2): ACS-CP-L Rev. E Assistant Control Panel (Asia): ACS-CP-D Rev. M

Xem trang 45 lm th no tm ra phin bn ca Assistant Control Panel ca bn xem tham s 9901 LANGUAGE xem cc ngn ng c h tr khc nhau bi Assistant Control Panels.

Control panels

42

ACS550 Users Manual

Assistant Control Panel


Tnh nng Cc tnh nng Assistant Control Panel :
K t s bng hin th mt mng hnh LCD la chn ngn ng cho hin th . Start-up Assistant d dng a n bin tn . chc nng sao chp thng s c th c sao chp n thng s bng iu khin sau ny chuyn giao n bin tn khc hoc lu cho 1 h thng c th. Gip tnh chnh xc ng h thi gian thc.

Tng quan Bng sau y tm tc cc chc nng chnh v hin th trn Assistant Control Panel.
1

S.
1
49.1Hz

s dng tnh trng LED xanh cho hot ng bnh thng.Nu LED nhy, hoc , xem chn Diagnostic displays trn trang 243. mng hnh LCD chia lm 3 khu vc chnh:
a. tnh trng bin, ty thuc vo phng thc hot ng, xem phn Status line trn trang 43. b. bin trung tm; ni chung , cho thy tn hiu v gi tr tham s, menu hoc danh sch. Cng cho thy cc li v bo ng. c. line di cho thy chc nng hin ti ca 2 phm mm v, nu c, kch hot ,mng hnh hin th ng h.

2a LOC 2b 2c

49 RPM 0.5 A 10 dm3/s


DIR 12:45 MENU

3 7 9

5 6

4 8 10

3 4 5

phm mm 1 chc nng ph thuc thuc tnh.Cc vn bn gc di bn tri ca mng hnh LCD cho thy cc chc nng. phm mm 2 chc nng ph thuc thuc tnh.Cc vn bn gc di bn phi ca mng hnh LCD cho thy cc chc nng. Up cun ln thng qua 1 menu danh sch hin th trung tm ca mng hnh LCD. gia s mt gi tr ca thm s c chn. gia s gi tr tham kho nu gc trn bn phi c t m . Gi phm xung thay i gi tr nhanh hn. Down cun ln thng qua 1 menu danh sch hin th trung tm ca mng hnh LCD. gia s mt gi tr ca thm s c chn. gia s gi tr tham kho nu gc trn bn phi c t m . Gi phm xung thay i gi tr nhanh hn.
LOC/REM thay i gia iu khin cc b v kim sot t xa ca bin tn.

7 8

tr gip hin th thng tin nhy cm khi nhn phm. Cc thng tin hin th m t hin ti bt sng ln trung tm ca mng hnh hin th
. STOP dng bin tn trong ch kim sot cc b. START khi ng bin tn trong ch kim sot cc b.

9 10

Control panels

ACS550 Users Manual

43

Tnh trng dng Dng trn cng ca mng hnh LCD hin th thng tin trng thi c bn ca bin tn.
LOC 1 No. Field 1 2 Alternatives 49.1Hz 4 LOC 1 2 MAIN MENU 3 1 4

Significance

Kim sot v tr

LOC REM

Kim sot bin tn l cc b, l t bng iu khin. Kim sot bin tn l t xa, chng hn nh I/O hoc tn hiu. Chiu thun hng trc Chiu nghch hng trc

Trng thi
Rotating arrow Dotted rotating arrow Stationary arrow Dotted stationary arrow

Bin tn ang chy im t. Bin tn ang chy nhng khng im t. Bin tn dng. C lnh khi ng nhng ng c khng chy, e.g. bi v khi ng b thiu lnh
tn ca ch hin hnh tn ca dang sch hoc menu hin hnh tn ca ch hot ng, e.g. PAR EDIT gi tr tham kho ch u ra s ca mc sng ln, e.g ch tham s nhm hoc li.

Hnh thc hat ng bng iu khin Gi tr tham kho hoc s ca chn item

Hot ng Hot ng bng iu khin vi menu v cc phm . Cc phm bao gm 2 tn hiu chnh xc phm mm, c chc nng hin ti l ch bo bng vn bn c hin th trong mng hnh hin th trn mi phm .
v Bn chn mt tu chn,e.g.hnh thc hot ng hoc tham s,bi di chuyn phm mi tn n khi chn c t m (in reverse video) v sau nhn cc phm mm khc. Vi phm phi mm bn thng nhp 1 ch , chp nhn mt la chn hoc lu thay i. Phm mm tri c s dng hy b cc thay i v tr v mc hot ng trc .

Assistant Control Panel c 9 bng ch : u ra, thng s, tr gip,thay i tham s ghi li, thi gian v ngy, thng s sao lu, I/O ci t v li . Cc hot ng trong 8 ch u tin c m t trong chng ny . Khi mt li hoc bo ng xy ra , bng iu khin t ng chuyn sang ch hin th li hoc bo ng . Bn c th reset n trong u ra hoc ch li (xem chng Diagnostics).

Control panels

44

ACS550 Users Manual

Ban u, bng iu khin ch u ra, ni bn c th LOC 49.1Hz khi ng, dng, thay i hng, chuyn i gia kim 49.1 Hz sot cc b v iu khin t xa, sa i cc gi tr tham 0.5 A chiu v mng hnh ln 3 gi tr thc t . lm nhim v 10.7 % 00:00 MENU khc,i ti menu chnh v chn ch thch hp trn menu. DIR Tnh trng ng dn (xem phn Status line trn trang 43) LOC MAIN MENU 1 cho thy tn ca menu hin ti , phng thc, trng d PARAMETERS ASSISTANTS liu hoc trng thi .

CHANGED PAR
EXIT 00:00

Lm th no lm nhim v chung

ENTER

Bng di y lit k nhim v ph bin, ch trong bn c th thc hin chng v s lng trang m cc bc lm nhim v chi tit .
Nhim v Lm th no c gip Lm th no tm ra phin bn ca bng iu khin Lm th no iu chnh tng phn ca mng hnh Lm th no chuyn i iu khin cc b v kim sot t xa Lm th no khi ng v dng bin tn Lm th no thay i hng quay ca ng c Lm th no t tc , tn s hoc momen xon tham chiu Lm th no thay i gi tr mt tham s Lm th no chn tn hiu gim st
Mode Any At power up Output Any Any Output Output Parameters Parameters Page 45 45 48 46 46 47 48 49 50 51 54 55 249 56

Lm th no lm nhim v hng dn (t im k thut ca b Assistants thng s) vi assistants Changed Parameters Lm th no xem v thay i cc thng s Lm th no xem li Lm th no reset li v bo ng Lm th no hin/n ng h. Thay i ngy v nh dng thi gian, thit lp ng h v bt tt ng h t ng theo nh sng ban ngy thay i tit kim Lm th no sao chp thng s t bin tn vo bng iu khin Parameter Backup Lm th no khi phc li cc thng s t bng iu khin Lm th no xem thng tin sao lu
Parameter Backup Parameter Backup Fault Logger Output, Fault

59 59 60 61

Lm th no chnh sa v thay i thng s lin quan n I/O thit b ci t I/O

Control panels

ACS550 Users Manual

45

Lm th no c gip
Step 1. Action Display
?

Nhn

c cc vn bn tr gip cho cc mc c t m .

LOC PAR GROUPS 10 01 OPERATING DATA 03 FB ACTUAL SIGNALS 04 FAULT HISTORY 10 START/STOP/DIR 11 REFERENCE SELECT EXIT 00:00 SEL LOC HELP This group defines external sources (EXT1 and EXT2) for commands that enable start, stop and EXIT 00:00 . LOC HELP external sources (EXT1 and EXT2) for commands that enable start, stop and direction changes. EXIT 00:00 LOC PAR GROUPS 10 01 OPERATING DATA 03 FB ACTUAL SIGNALS 04 FAULT HISTORY 10 START/STOP/DIR 11 REFERENCE SELECT EXIT 00:00 SEL

Nu tr gip tn ti cho mc ny, n s c hin th trn mng hnh .

2.

Nu ton b vn bn khng hin th,di chuyn vi phm

3.

Sau khi c vn bn, tr v mng hnh hin th trc bi nhn

EXIT

Lm th no tm ra phin bn ca bng iu khin


Bc
1. 2.

hot ng Nu ngun c bt, cng tt tc . Gi phm ? nhn xung trong khi bn chuyn i ngun in v c thng tin mng hnh hin th cc thng tin t bng sau y : Panel FW: panel firmware version ROM CRC: panel ROM kim tra tng hp Flash Rev: ni dung phin bn flash Ni dung nhn xt Flash. Khi bn nh phm
?

Hin th

PANEL VERSION INFO Panel FW: x.xx ROM CRC: xxxxxxxxxx Flash Rev: x.xx xxxxxxxxxxxxxxxxxxxxx

bng iu khin i vo ch u ra.

Control panels

46

ACS550 Users Manual

Lm th no khi ng , dng v chuyn i gia kim sot cc b v kim sot t xa ? Bn c th khi ng, dng v chuyn i gia kim sot cc b v t xa. c th khi ng hoc dng bin tn, bin tn phi c kim sot cc b.
Bc
1.

hot ng
Chuyn i gia kim sot t xa (REM hin th trn dng trng thi ) v kim

Hin th
LOC MESSAGE Switching to the local control mode.

sot cc b (LOC hin th trn dng trng thi ), nhn REM LOC . ch : chuyn mch n kim sot cc b c th b v hiu ha bi tham s 1606 LOCAL LOCK. Ln u tin bin tn c cp ngun, n ch kim sot t xa (REM v kim sot bin tn thng qua cc ng I/O.Chuyn i n kim sot cc b (LOC) v kim sot bin tn bng cch dng bng iu khin, nhn LOC . REM Kt qu ph thuc vo khong thi gian bn nhn phm :
REM

00:00

Nu bn nh phm ngay lp tc (mng hnh nhp nhychuyn i n ch

iu khin cc b), bin tn dng . t cc tham chiu cc b theo hng dn trn trang 48.
Nu bn nhn phm trong khong 2 giy, bin tn vn tip tc nh trc.

bin tn sao chp gi tr hin ti t xa cho chy /dng tnh trng v ti liu tham kho, v s dng chng nh l ci t kim sot cc b ban u.
dng bin tn trong kim sot cc b,nhn chy bin tn trong kim sot cc b,nhn . .

Mi tn ( hoc )trn dng trng thi dng xoay. Mi tn ( hoc ) trn dng trng thi bt u quay. n chm chm n khi bin tn t n im t.

Control panels

ACS550 Users Manual

47

Hnh thc u ra Trong hnh thc u ra , bn c th :


gim st gi tr thc t ln n 3 tn hiu trong nhm 01 OPERATING DATA. thay i hng quay ca ng c . t tc , tn s hoc momen xon tham kho . iu chnh tng phn mng hnh . khi ng,dng, thay i hng v chuyn i gia kim sot cc b v kim sot t xa.

Bn i n ch u ra bng cch nhn

EXIT

nhiu ln.
49.1Hz LOC HZ 5.0Hz 50%

Gc trn bn phi ca mng LOC hnh hin th l gi tr tham kho 49.1 Hz . trung tm mng hnh c th 0.5 A hin th ti a 3 gi tr tn hiu 10.7 % DIR 00:00 hoc th thanh; xem trang 50 c hng dn la chn v sa i tn hiu gim st . Lm th no thay i hng quay ca ng c
Step 1. Action

MENU

DIR

0.4 A 24.4 %
00:00

MENU

Display
EXIT

Nu bn khng ch ng ra, nhn

nhiu ln cho n khi bn nhn c .

REM

49.1Hz

DIR 2.

49.1 Hz 0.5 A 10.7 %


00:00

MENU 49.1Hz

Nu bin tn ang kim sot t xa (REM hin trn dng trng thi), chuyn LOC i n kim sot cc b bng cch nhn LOC . mng hnh hin th mt thi gian REM ngn cho thy mt thng ip v thay i ch v sau tr v ch u ra.
REM

DIR 3.

49.1 Hz 0.5 A 10.7 %


00:00

MENU 49.1Hz

n thay i hng quay t thun ( hin trn dng trng thi) n quay ngcLOC DIR . (hin trn dng trng thi),hoc ngc li,nhn Ch : tham s 1003 DIRECTION phi c t n 3 (REQUEST)

DIR

49.1 Hz 0.5 A 10.7 %


00:00

MENU

Control panels

48

ACS550 Users Manual

Lm th no t tc , tn s hoc momem xon tham kho .


Step 1. Action Display
EXIT

Nu bn khng ch ng ra, nhn

lin tc cho n khi bn nhn c.

REM

49.1Hz

DIR 2.

49.1 Hz 0.5 A 10.7 %


00:00

MENU 49.1Hz

Nu bin tn ang kim sot t xa (REM hin trn dng trng thi) , chuyn LOC i n kim sot cc b bng cch nhn LOC .Mng hnh hin th mt thi gian REM ngn cho thy mt thng ip v thay i ch v sau tr v ch u ra.
REm

Ch : vi nhm 11 REFERENCE SELECT, bn c th cho php sa i ti liu trong kim sot t xa.
3.

DIR

49.1 Hz 0.5 A 10.7 %


00:00

MENU 50.0Hz

tng gim gi tr tham chiu c nh du hin th gc trn bn phi ca LOC mng hnh,nhn . gi tr thay i ngay lp tc. N c lu trong b nh thng trc ca bin tn v t ng phc hi sau khi chuyn i ngun tc off. gim gi tr ,nhn . DIR

50.0 Hz 0.5 A 10.7 %


00:00

MENU

Lm th no iu chnh tng phn ca mng hnh


Step 1. Action Display
EXIT

Nu bn khng ch ng ra, nhn

lin tc cho n khi bn nhn c.

LOC

49.1Hz

DIR 2. tng tng phn, nhn cc phm


MENU MENU

49.1 Hz 0.5 A 10.7 %


00:00

MENU 49.1Hz

v v

ng thi. ng thi.

LOC

gim tng phn, nhn cc phm

DIR

49.1 Hz 0.5 A 10.7 %


00:00

MENU

Control panels

ACS550 Users Manual

49

Ch tham s Trong hnh thc tham s ny , bn c th:


Xem v thay i gi tr tham s Khi ng, dng, thay i hng v chuyn i gia kim sot cc b v kim sot t xa.

Lm th no chn tham s v thay i gi tr ca n .


Step 1. Action Display
MENU

i n menu chnh bi nhn nu bn ang ch ng ra , nu EXIT khng nhn lin tc cho n khi bn thy menu chnh di

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER LOC PAR GROUPS 01 01 OPERATING DATA 03 FB ACTUAL SIGNALS 04 FAULT HISTORY 10 START/STOP/DIR 11 REFERENCE SELECT EXIT 00:00 SEL LOC PAR GROUPS 99 99 START-UP DATA 01 OPERATING DATA 03 FB ACTUAL SIGNALS 04 FAULT HISTORY 10 START/STOP/DIR EXIT 00:00 SEL LOC PARAMETERS 9901 LANGUAGE ENGLISH 9902 APPLIC MACRO 9904 MOTOR CTRL MODE 9905 MOTOR NOM VOLT EXIT 00:00 EDIT

2.

i n ch thng s bng cch chn PARAMETERS trn menu vi phm ENTER . v , v nhn

3.

Chn tham s nhm thch hp vi phm

Nhn

SEL

4.

Chn tham s thch hp vi phm tham s l cc tham s c hin th di y.

PARAMETERS . gi tr hin ti ca LOC 9901 LANGUAGE 9902 APPLIC MACRO ABB STANDARD 9904 MOTOR CTRL MODE 9905 MOTOR NOM VOLT EXIT 00:00 EDIT LOC PAR EDIT

Nhn

EDIT

9902 APPLIC MACRO [1] CANCEL 00:00 5.

ABB STANDARD
SAVE PAR EDIT

Ch nh mt gi tr mi cho tham s vi cc phm

LOC

nhn phm mt ln tng hoc gim gi tr. Gi phm xung thay i gi tr nhanh hn. Nhn cc phm ng thi thay th cc gi tr hin th vi gi tr mc nh.
6. Lu gi tr mi , nhn
SAVE

9902 APPLIC MACRO

3-WIRE

[2] CANCEL 00:00

SAVE

.
CANCEL

Hy cc gi tr mi v gi nguyn bn, nhn

LOC PARAMETERS 9901 LANGUAGE 9902 APPLIC MACRO 3-WIRE 9904 MOTOR CTRL MODE 9905 MOTOR NOM VOLT EXIT 00:00 EDIT

Control panels

50

ACS550 Users Manual

Lm th no chn tn hiu gim st


Step 1. Action Display LOC PAR EDIT

Bn c th chn nhng tn hiu gim st trong ch u ra v cch chng c hin th vi nhm thng s 34 PANEL DISPLAY . Xem trang 49 c hng dn chi tit v thay i gi tr tham s. Theo mc nh, hin th cho thy 3 tn hiu. nhng tn hiu mc nh c th ph thuc gi tr ca tham s 9902 APPLIC MACRO: vi cc macro c gi tr mc nh ca tham s9904 MOTOR CTRL MODE l 1 (VECTOR:SPEED) mc nh cho tn hiu 1 l 0102 SPEED, nu khng l 0103 OUTPUT FREQ. mc nh tn hiu 2 v 3 lun 0104 CURRENT v 0105 TORQUE, tng ng. n thay i tn hiu mc nh, chn n 3 tn hiu nhm 01 : OPERATING DATA c hin th. Tn hiu 1: thay i gi tr ca tham s 3401 SIGNAL1 PARAM n ch s ca tn hiu tham s trong nhm 01 OPERATING DATA(= s ca tham s ny m khng s khng u), e.g. 105 ngha l tham s 0105 TORQUE gi tr 0 ngha l tn hiu khng c hin th. Lp li cho cc tn hiu 2 (3408 SIGNAL2 PARAM) v 3 (3415 SIGNAL3 PARAM

3401 SIGNAL1 PARAM [103] CANCEL LOC

OUTPUT FREQ
00:00 SAVE PAR EDIT

3408 SIGNAL2 PARAM [104] CANCEL LOC

CURRENT
00:00 SAVE PAR EDIT

3415 SIGNAL3 PARAM [105] CANCEL LOC

TORQUE
00:00 SAVE

2.

Bn mun chn tn hiu s c hin th : l s hoc th thanh .Vi s thp phn, bn c th ch nh v tr im thp phn , hoc s dng v tr cc im thp phn v n v ca ngun tn hiu [ci t (9 (DIRECT)]. chi tit, xem tham s 3404. Tn hiu 1: tham s 3404 OUTPUT1 DSP FORM Tn hiu 2: tham s 3411 OUTPUT2 DSP FORM Tn hiu 3: tham s 3418 OUTPUT3 DSP FORM.

PAR EDIT

3404 OUTPUT1 DSP FORM

DIRECT
00:00

[9] CANCEL

SAVE

3.

Chn cc n v s c hin th cho cc tn hiu. iu ny khng c tc dng 3404/3411/3418 thit lp n 9 (DIRECT). Chi tit, xem tham s 3405. Tn hiu 1: tham s 3405 OUTPUT1 UNIT Tn hiu 2: tham s 3412 OUTPUT2 UNIT Tn hiu 3: tham s 3419 OUTPUT3 UNIT.

LOC

PAR EDIT

3405 OUTPUT1 UNIT

Hz

[3] CANCEL LOC

00:00

SAVE

4.

Chn t l cho cc tn hiu bng cch xc nh cc gi tr hin th nh nht v ln nht. N khng c tc dng nu tham s 3404/3411/3418 c t n 9 (DIRECT). Chi tit , xem tham s 3406 v 3407. Tn hiu 1: tham s 3406 OUTPUT1 MIN v 3407 OUTPUT1 MAX Tn hiu 2: tham s 3413 OUTPUT2 MIN v 3414 OUTPUT2 MAX Tn hiu 3: tham s 3420 OUTPUT3 MIN v 3421 OUTPUT3 MAX.

PAR EDIT

3406 OUTPUT1 MIN

0.0 Hz
00:00 PAR EDIT

CANCEL LOC

SAVE

3407 OUTPUT1 MAX

500.0 Hz
00:00

CANCEL

SAVE

Control panels

ACS550 Users Manual

51

Assistants mode

Khi ln u tin m ngun bin tn, Start-up Assistant hng dn bn thng qua ci t cc thng s c bn. Start-up Assistant c chia thnh nhiu phn ph, mi phn c trch nhim cho cc c im k thut ca mt b tham s lin quan, v d: Motor Setup hoc PID Control . Start-up Assistant kch hot sau khi mt phn ph khc kch hot bn cng c th s dng cc phn ph c lp. bit thm thng tin v nhim v ca cc phn ph khc, xem phn Start-up Assistant trn trang 52. Trong ch the Assistants, bn c th:
S dng assistants hng dn bn thng qua cc t im k thut ca tp hp cc thng s c bn Khi ng ,dng thay i hng v chuyn i gia iu khin cc b v iu khin t xa. How to use an assistant

Bng di y cho thy trnh t hot ng c bn hng dn bn thng qua tr gip. Motor Set-up Assistant c s dng nh v d.
Step 1. Action Display
MENU

i n Main menu bi nhn nu bn ang ch ng ra,nu EXIT khng nhn lin tc cho n khi bn nhn thy menu chnh .

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER LOC ASSISTANTS 1 Start-up assistant Motor Set-up Application Speed control EXT1 Speed control EXT2 EXIT 00:00 SEL PAR EDIT

2.

i n ch the Assistants bi chn ASSISTANTS trn menu vi cc phm


v , v nhn
ENTER

3.

Chn assistant vi cc phm

, v nhn

SEL

. nu bn chn LOC

bt k tr gip khc hn l Start-up Assistant, n hng dn bn thng qua cc 9905 MOTOR NOM VOLT nhim v t im k thut ca tham s,n thit lp nh trong bc 4.v 5 . 220 V di y. Sau bn c th chn mt tr gip trn Assistants menu thot khi ch Assistants. Motor Set-up Assistant c s dng y nh l v d. 00:00 EXIT SAVE Nu bn chn Start-up Assistant,n kch hot assistant u tin,hng dn bn thng qua nhim v c im k thut ca tham s n t nh trong bc 4. v 5. di y. Start-up Assistant sau hi bn c mun tip tc vi tr gip v tip theo hoc b qua n v chn cu tr li tng thch vi phm SEL , v nhn . Nu bn b qua, Start-up Assistant hi cng mt cu hi v tr gip tip theo , v nh vy.
4. xc nh mt gi tr mi,nhn phm v . LOC CHOICE Do you want to continue with application setup? Continue Skip EXIT 00:00

OK

LOC

PAR EDIT

9905 MOTOR NOM VOLT

240 V
00:00

EXIT c thng tin v cc thng s yu cu, nhn phm


?.

SAVE

bn vi phm gip

. ng gip bi nhn

HELP di chuyn vn LOC given on the Set as EXIT .

motor nameplate. Voltage value must correspond to motor D/Y connection. EXIT 00:00

Control panels

52

ACS550 Users Manual

Step 5.

Action chp nhn cc gi tr mi v tip tc ci t cc thng s tip theo , SAVE . nhn dng tr gip , nhn
EXIT

Display LOC PAR EDIT

9906 MOTOR NOM CURR

. EXIT

1.2 A
00:00

SAVE

Bng sau y lit k cc nhim v ca assistants v cc thng s bin tn lin quan. Ty thuc trn cc la chn thc hin trong nhim v ca ng dng (tham s 9902 APPLIC MACRO), Start-up Assistant l quyt nh, m n cho thy hu qu nhim v.
tn Language select Motor set-up M t La chn ngn ng Thit lp d liu ng c Thc hin vic xc nh ng c. (nu cc gii hn tc khng nm Trong phm vi cho php: thit lp gii hn .) Ch ng dng macro Kch hot ty chn module Thit lp cc tham s 9901 99049909 9910 9902, cc thng s lin quan n macro nhm 35: MOTOR TEMP MEAS nhm 52: PANEL COMM 9802 1103 (13011303, 3001) 1104, 1105 2001, 2002, (2007, 2008) 2202, 2203 1106 (13011303, 3001) 1107, 1108 1106 (13011303, 3001) 1107, 1108 2401, 2402 1106 (13011303, 3001) 1107, 1108 2001, 2002, (2007, 2008) 4016, 4018, 4019 1001, 1002 1102 1003 21012103 1601 Group 36: TIMED FUNCTIONS 1001, 1002 1102 1201

Application Option modules

Speed control EXT1

Chn ngun cho cc tham chiu tc (nu AI1 c s dng : thit lp gii hn u vo tng t AI1, t l,o ngc ) Thit lp cc gii hn tham chiu Thit lp gii hn tc (tn s) Thit lp thi gian tng tc gim tc

Speed control EXT2

Chn ngun cho cc tham chiu tc (nu AI1 c s dng : thit lp gii hn u vo tng t AI1, t l,o ngc) Thit lp cc gii hn tham chiu Chn ngun cho momen xon tham chiu (nu AI1 c s dng : thit lp gii hn u vo tng t AI1, t l,o ngc) Thit lp cc gii hn tham chiu Thit lp dc thi gian ln v xung cho momen xon

Torque control

PID control

Chn ngun cho tham chiu qu trnh (nu AI1 c s dng :thit lp gii hn u vo tng t AI1, t l,o ngc) Thit lp cc gii hn tham chiu Thit lp gii hn tc (tn s) Thit lp ngun v gii hn cho qu trnh gi tr thc t

Start/Stop control

chn ngun cho tn hiu khi ng v dng ca hai im kim sot bn ngoi, EXT1 v EXT2 chn gia EXT1 v EXT2 quy nh hng kim sot quy nh ch khi ng v dng chn s dng tn hiu Run Enable

Timed functions

Thit lp cc chc nng hn gi Chn kim sot thi gian khi ng/dng cho v tr kim sot ngoi EXT1 v EXT2 Chn thi gian kim sot EXT1/EXT2 Kch hot thi gian tc khng i 1

Control panels

ACS550 Users Manual

53

Name

Description Chn trng thi chc nng hn gi ch nh thng qua u ra relay RO Chn thng s ci t hn gi PID1 kim sot 1/2

Set parameters 1401 4027 2003, 2017 nhm 14: RELAY OUTPUTS nhm 15: ANALOG OUTPUTS

Protections Output signals

Thit lp gii hn dng in v momen xon Chn ch ra tn hiu thng qua u ra relay RO Chn ch ra tn hiu thng qua u ra tng t AO Thit lp nh nht, ln nht, t l v o ngc

Control panels

54

ACS550 Users Manual

Thay i ch tham s Trong ch thay i tham s , bn c th : xem danh sch ca tt c tham s c thay i t gi tr mc nh macro
thay i cc tham s ny khi ng, dng, thay i hng cc chuyn i gia kim sot cc b v kim sot t xa.

Lm th no xem v sa i cc thng s
Step 1. Action Display
MENU

i n Main menu bi nhn nu bn ang ch ng ra , nu EXIT khng nhn lin tc cho n khi bn i n menu chnh.

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER LOC CHANGED PAR 1202 CONST SPEED 1 10.0 Hz 1203 CONST SPEED 2 1204 CONST SPEED 3 9902 APPLIC MACRO EXIT 00:00 EDIT LOC PAR EDIT

2.

i n ch thay i tham s bng cch chn CHANGED PAR trn ENTER . menu vi phm v , v nhn

3.

Chn thay i tham s trn anh sch vi phm ca tham s c chn s c hin th di n, nhn gi tr.

v
EDIT

. gi tr sa i cc

1202 CONST SPEED 1

10.0 Hz
PAR EDIT

CANCEL 00:00 4.

SAVE

Ch nh mt gi tr mi cho tham s vi cc phm

LOC

nhn phm mt ln tng hoc gim gi tr . Gi phm xung thay i gi tr nhanh hn. Nhn cc phm ng thi thay th cc gi tr hin th vi gi tr mc nh.
5. chp nhn gi tr mi, nhn . Nu gi tr mi l gi tr mc nh, tham s c ly ra t danh sch cc tham s thay i.
CANCEL SAVE

1202 CONST SPEED 1

15.0 Hz

CANCEL 00:00

SAVE

hy cc gi tr mi v gi nguyn bn, nhn

LOC CHANGED PAR 1202 CONST SPEED 1 15.0 Hz 1203 CONST SPEED 2 1204 CONST SPEED 3 9902 APPLIC MACRO EXIT 00:00 EDIT

Control panels

ACS550 Users Manual

55

Fault Logger mode

Trong ch Fault Logger, bn c th:


Xem lch s li ca bin tn nhiu nht 10 li (sau khi tc ngun, ch c 3 li mi nht c lu trong b nh) Xem chi tit trong 3 li mi nht (sau khi tc ngun, cc chi tit ca cc li gn y nht c gi trong b nh) c cc vn bn tr gip ca li Khi ng, dng, thay i hng v chuyn i gia kim sot cc b v iu khin t xa.

Lm th no xem li
Step 1. Action Display
MENU

i n menu chnh bi nhn nu bn ang ch ng ra,nu EXIT khng nhn nhiu ln n khi bn i n menu chnh.

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER LOC FAULT LOG 10: PANEL LOSS 19.03.05 13:04:57 6: DC UNDERVOLT 6: AI1 LOSS EXIT 00:00 DETAIL

2.

i n ch Fault Logger bng cch chn FAULT LOGGER trn menu vi ENTER phm v , v nhn . Mng hnh hin th li bt u vi cc li mi nht. S trn hng l s ca li theo nguyn nhn v cch khc phc c lit k trong chng Diagnostics.

3.

Xem chi tit ca 1 li, chn n vi phm


DETAIL

, v nhn

PANEL LOSS LOC FAULT 10 FAULT TIME 1 13:04:57 FAULT TIME 2 EXIT 00:00 DIAG LOC DIAGNOSTICS Check: Comm lines and connections, parameter 3002, parameters in groups 10 and 11. EXIT OK 00:00

4.

Hin th vn bn tr gip,nhn
.

DIAG

. di chuyn vi cc phm gip

sau khi c tr gip , nhn

OK

tr v mng hnh hin th trc .

Control panels

56

ACS550 Users Manual

Clock Set mode Trong ch Clock Set, bn c th: Hin th hoc n ng h Thay i nh dng hin th ngy thng v thi gian t ngy v thi gian Kch hot hoc v hiu ho qu trnh chuyn i ng h t ng thay i theo nh sng

ban ngy
Khi ng, dng, thay i hng v chuyn i gia kim sot cc b v iu khin t xa.

Assistant Control Panel c cha mt pin m bo chc nng ca ng h khi bng ny khng c cp ngun bi bin tn.

Lm th no hin th hoc n ng h, thay i nh dng hin th ,t ngy v thi gian v cho php hoc v hiu ha qu trnh chuyn i ng h thay i tit kim theo nh sng ban ngy
Step 1. Action Display
MENU

i n menu chnh bng cch nhn nu bn ang ch ng ra,nu EXIT khng nhn nhiu ln n khi bn i n menu chnh .

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER 1

2.

TIME & DATE i n ch Time and Date bng cch chn TIME & DATE trn menu vi phmLOC ENTER CLOCK VISIBILITY . v , v nhn TIME FORMAT DATE FORMAT SET TIME SET DATE EXIT 00:00

SEL 1

3.

Hin th (n) ng h, chn CLOCK VISIBLILITY trn menu, nhn

chn hin th ng h (n ng h) v nhn v mng hnh trc m khng thay i , nhn

SEL

SEL

, hoc nu bn mun tr EXIT .

LOC CLOCK VISIB Show clock Hide clock

EXIT xc nh inh dng ngy, chn DATE FORMAT trn menu, nhn
SEL OK CANCEL

00:00

SEL 1

v chn mt nh dng ph hp.nhn ca bn.

lu hoc

hy b thay i

LOC DATE FORMAT dd.mm.yy mm/dd/yy dd.mm.yyyy mm/dd/yyyy CANCEL 00:00 OK

xc nh nh dng thi gian, chnTIME FORMAT n menu, nhn

SEL

v chn mt nh dng ph hp.nhn ca bn.

OK

lu hoc

CANCEL

hy b thay i

LOC TIME FORMAT 24-hour 12-hour

CANCEL t thi gian, chn SET TIME trn menu v nhn . xc nh gi OK vi cc phm v , v nhn . sau ghi r vo bin bn. OK CANCEL Nhn lu hoc hy b thay i ca bn.
SEL

00:00

OK

LOC

SET TIME

15:41
CANCEL 00:00 OK

Control panels

ACS550 Users Manual

57

Step

Action LOC chn SET DATE trn menu v nhn . Ch nh ln u tin mt phn ca ngy (ngy hoc thng ty thuc vo nh dng ngy thng) OK vi phm v , v nhn . lp li cho phn th hai. Sau OK CANCEL . lu thay i , nhn . hy thay i ca bn, nhn t ngy ,
SEL

Display SET DATE

19.03.05
00:00 OK

CANCEL bt hoc v hiu ha qu trnh chuyn i ng h t ng thay i theo SEL . nh sng ban ngy, chn DAYLIGHT SAVING trn menu v nhn

Nhn ? m ra s gip cho thy s bt u v kt thc ca thi gian m nh sng ban ngy tit kim ,c s dng trong mi quc gia hoc khu vc tit kim nh sng ban ngy c th thay i , bn c th chn sau y.
v hiu ha qu trnh chuyn i ng h t ng tit kim thay i theo SEL . nh sng, chn Off v nhn kch hot hiu ng chuyn tip ng h t ng, chn quc gia hoc khu SEL . vc tit kim nh sng ban ngy thay i bn c th chn tr v mng hnh trc m khng thay i, nhn
EXIT

LOC DAYLIGHT SAV 1 Off EU US Australia1:NSW,Vict.. Australia2:Tasmania.. EXIT 00:00 SEL LOC HELP EU: On: Mar last Sunday Off: Oct last Sunday US: EXIT 00:00

Control panels

58

ACS550 Users Manual

Thng s ch sao lu Ch Parameter Backup c s dng xut cc thng s t bin tn n


1 ci khc hoc sao lu thng s cc bin tn. Ti ln n b nh bng iu khin

thng s bin tn, trong c n 3 b phn s dng, n Assistant Control Panel thit lp y , mt phn thng s t (ng dng) v ngi s dng sau c th ti v t bng iu khin n bin tn khc hoc bin tn nh vy.
B nh bng iu khin khng d mt i v khng ph thuc vo pin ca bng iu khin.

Trong ch Parameter Backup bn c th:


Sao chp tt c thng s t bin tn n bng iu khin (UPLOAD TO PANEL).

iu ny bao gm tt c cc phn s dng v thng s ni b (khng iu chnh c bi ngi dng) cc thng s to ra bi ID Run.
Xem thng tin v cc sao lu c lu tr vo bng iu khin vi UPLOAD

TO PANEL (BACKUP INFO). Bao gm e.g. loi v phm vi ca bin tn ni thc hin sao lu. N rt hu ch kim tra thng tin ny khi bn s sao chp cc thng s bin tn khc vi DOWNLOAD FULL SET m bo rng cc bin tn ph hp .
Khi phc li ton b cc thng s t bng iu khin cho bin tn (DOWNLOAD

FULL SET). Vit tt c cc thng s ny, bao gm cc ni dung ngi dng khng th iu

chnh thng s ng c, n bin tn. N khng bao gm b thng s s dng . ch : ch s dng chc nng ny khi phc bin tn t sao lu hoc tham s chuyn giao cho h thng trng vi h thng ban u .
Sao chp mt phn tham s ci t (1 phn ca tp hp y ) t bng iu khin n

bin tn(DOWNLOAD APPLICATION). Ci t mt phn khng bao gm phn ngi s dng, cc thng s bn trong, tham s 99059909, 1605, 1607, 5201, khng bao gm nhm 51 EXT COMM MODULE v tham s 53 EFB PROTOCOL. Ngun v mc tiu bin tn v kch c h ng c khng cn phi ging nhau.
Copy USER S1 tham s t bng iu khin n bin tn (DOWNLOAD

USER SET1). Tp hp ci t s dng gm nhm 99 START-UP DATA tham s v thng s ni b ng c. Chc nng ny hin th trn menu khi User Set 1 c lu li bi s dng tham s u tin 9902 APPLIC MACRO ( xem phn User macros trn trang 81) v sau ti ln bng iu khin vi UPLOAD TO PANEL.
Copy USER S2 tham s t bng iu khin n bin tn (DOWNLOAD USER SET2). nh DOWNLOAD USER SET1 trn. Khi ng, dng, thay i hng v chuyn i gia kim sot cc b v kim sot t xa.

Control panels

ACS550 Users Manual

59

Lm th no ti ln ti v cc thng s . ti ln ti v cc chc nng c sn, xem trn.


Step 1. Action Display
MENU

i n menu chnh bi nhn nu bn ang trong ch ng ra, nu EXIT khng nhn lin tc cho n khi bn i ti menu chnh.

LOC

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER

MAIN MENU

2.

i n ch Par Backup bi chn PAR BACKUP trn menu vi cc phm ENTER . v , v nhn

LOC COPY MENU 1 UPLOAD TO PANEL BACKUP INFO DOWNLOAD FULL SET DOWNLOAD APPLICATION DOWNLOAD USER SET1 EXIT 00:00 SEL LOC PAR BACKUP 50%

3.

copy tt c cc tham s (bao gm s dng ci t v tham s ni b) t

bin tn n bng iu khin, chn UPLOAD TO PANEL trn Par Backup vi Copying parameters SEL phm v , v nhn . trong thi gian chuyn giao, mng hnh ABORT hin th cho thy tnh trng chuyn giao nh t l phn trm hon thanh nhn nu bn mun dng hot ng. ABORT 00:00 Sau khi ti ln xong , mng hnh hin th mt thng bo hon thnh OK nhn tr v menu Copy.
LOC MESSAGE Parameter upload successful.

OK thc hin ti v, chn hot ng thch hp ( y DOWNLOAD FULL v SET c s dng lm v d) trn Par Backup vi cc phm . mng hnh hin th trng thi chuyn giao l t l ABORT phn trm hon thnh. Nhn nu bn mun dng hot ng. , v nhn
SEL

00:00

LOC PAR BACKUP Downloading parameters (full set) ABORT 00:00

50%

Sau khi ti v xong, mng hnh hin th mt thng bo hon thnh OK nhn tr v menu Copy.

LOC MESSAGE Parameter download successfully completed. OK 00:00

Control panels

60

ACS550 Users Manual

Lm th no xem thng tin sao lu d phng.


Step 1. Action Display
MENU

i n menu chnh bi nhn nu bn ang ch ng ra, nu EXIT khng nhn nhiu ln cho n khi bn c c menu chnh .

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER LOC COPY MENU 1 UPLOAD TO PANEL BACKUP INFO DOWNLOAD FULL SET DOWNLOAD APPLICATION DOWNLOAD USER SET1 EXIT 00:00 SEL LOC BACKUP INFO DRIVE TYPE ACS550 3304 DRIVE RATING 4A62i 3301 FIRMWARE EXIT 00:00 LOC BACKUP INFO ACS550 3304 DRIVE RATING 4A62i 3301 FIRMWARE 300F hex EXIT 00:00

2.

i n chc nng Par Backup bi nhn PAR BACKUP trn menu vi phm ENTER . v , v nhn

3.

v Chn BACKUP INFO trn Par Backup vi cc phm SEL nhn mng hnh hin th cc thng tin v bin tn c thc hin sao lu : DRIVE TYPE: DRIVE RATING:

, v

kiu ca bin tn phm vi ca bin tn nh dng XXXYZ, trong : XXX: phm vi dng in danh nh . Nu c mt A ch ra mt im thp phn, v d. 4A6 ngha l 4.6 A.
Y: 2 = 200 V 4 = 400 V 6 = 600 V Z: i = European loading package n = US loading package

FIRMWARE:

phin bn vi chng trnh ca bin tn.


v . LOC COPY MENU 1 UPLOAD TO PANEL BACKUP INFO DOWNLOAD FULL SET DOWNLOAD APPLICATION DOWNLOAD USER SET1 EXIT 00:00 SEL

Bn c th cun thng tin vi cc phm


4. Nhn
EXIT

tr v menu Copy.

Control panels

ACS550 Users Manual

61

Chc nng ci t I/O Trong chc nng ci t I/O, bn c th :


Kim tra cc ci t thng s lin quan n thit b u cui I/O Sa cc thit lp thng s. v d , nu 1103: REF1 c lit k theo Ain1

(u vo tng t 1), ngha l, tham s 1103 REF1 SELECT c gi tr AI1, bn c th thay i gi tr ca n e.g. AI2. bn khng c th , tuy nhin, t gi tr ca tham s 1106 REF2 SELECT n AI1.
Khi ng, dng, thay i hng v chuyn i gia kim sot cc b v kim sot t xa

Lm th no chnh sa v thay i ci t thng s lin quan n thit b u cui I/O


Step 1. Action Display
MENU

i n menu chnh bi nhn nu bn ang ch ng ra, nu EXIT khng nhn nhiu ln n khi bn nhn c menu chnh .

LOC

MAIN MENU

PARAMETERS ASSISTANTS CHANGED PAR


EXIT 00:00 ENTER LOC I/O SETTINGS 1 DIGITAL INPUTS (DI) ANALOG INPUTS (AI) RELAY OUTPUTS (ROUT) ANALOG OUTPUTS (AOUT) PANEL EXIT 00:00 SEL LOC SHOW I/O DI1 1001:START/STOP (E1) DI2 DI3 EXIT 00:00 PAR EDIT 1

2.

i n ci t I/O bi chn ch I/O SETTINGS trn menu vi cc phm ENTER . v , v nhn

3.

v , v Chn nhm I/O, e.g. DIGITAL INPUTS, vi cc phm SEL nhn . Sau khi tm dng, mng hnh hin th cc ci t hin hnh i vi vic la chn.

4.

Chn ci t (ph hp vi tham s) vi cc phm


v nhn
EDIT

LOC

1001 EXT1 COMMANDS

DI1

[1] CANCEL 00:00 5.

SAVE

Ch nh mt gi tr ci t mi vi cc phm

LOC

PAR EDIT

Nhn phm mt ln tng hoc gim gi tr. Gi phm xung thay i gi tr nhanh hn. Nhn cc phm ng thi thay th gi tr hin th vi gi tr mc nh.
6. lu gi tr mi, nhn
SAVE

1001 EXT1 COMMANDS

DI1,2

[2] CANCEL 00:00

SAVE 1

.
CANCEL

hy cc gi tr mi v gi nguyn bn , nhn

LOC SHOW I/O DI1 1001:START/STOP (E1) DI2 1001:DIR (E1) DI3 EXIT 00:00

Control panels

62

ACS550 Users Manual

Basic Control Panel


Tnh nng Tnh nng Basic Control Panel :
Bng iu khin s vi mng hnh LCD . Sao chp chc nng thng s c th c sao chp vo b nh ca bng iu khin sau ny chuyn sang bin tn khc hoc sao lu ca mt h thng c th.

Tng quan Bng sau y tm tc cc chc nng chnh v hin th trn bng iu khin tch hp
.
s.
1 1a LOC 1c 1d OUTPUT

s dng Mng hnh LCD chia thnh 5 khu vc:


a. Trn bn tri iu khin v tr: LOC: : bin tn iu khin cc b iu khin t bng iu khin REM: bin tn iu khin t xa t tn hiu I/O ca bin tn. b. Trn bn phi n v ca gi tr hin th. c. Gia bin ; ni chung, cho thy cc thng s v gi tr tn hiu. cc menu hoc danh sch, ngoi ra bo ng v hin th li.

. 11

1b 1e

FWD

RESET EXIT

MENU ENTER

2 6 8

4 5

3 7 9

d. Gia v bn tri pha di trng thi thao tc bng: OUTPUT: kiu u vo PAR: kiu tham s MENU: menu chnh FAULT : kiu li. e. Di bn phi cc ch s:

FWD (chiu thun) / REV (chiu nghch): hng ca ng c quay Nhp nhy chm: dng li Nhp nhy nhanh: ang chy . Cha t im t Khng i: ang chy t im t SET : Hin th gi tr c th c sa i (trong tham s hay kiu tham s
). 2 3 4 RESET/EXIT Thot khi menu mc cao hn k tip m khng lu gi tr thay i. nhng li khi ng li trong u ra v nhng kiu li. MENU/ENTER Nhp su hn vo menu . ch thng s , lu gi tr, hin th nh trn cc ci t mi. Up Cun ln thng qua mt trnh n hoc danh sch. Tng gi tr nu mt tham s c chn. Tng gi tr tham kho ch tham kho. Gi phm xung thay i gi tr nhanh hn . Down Cun xung thng qua mt trnh n hoc danh sch. Lm gim gi tr nu mt tham s c chn. Lm gim gi tr tham kho ch tham kho. Gi phm xung thay i gi tr nhanh hn. LOC/REM Thay i gia kim sot cc b v kim sot t xa ca bin tn. DIR Thay i hng quay ca ng c. STOP Dng bin tn trong kim sot cc b. START Khi ng bin tn trong kim sot cc b..

6 7 8 9

Control panels

ACS550 Users Manual

63

Hot ng Hot ng bng iu khin ca bn vi cc menu v cc phm. Bn chn mt ty chn(v d,


v ch hot ng hay tham s)bng cch di chuyn phm mi tn chn c hin th trn mng hnh v sau nhn

cho n khi ty
phm.

Vi phm

bn quay tr li mc hot ng trc m khng lu thc hin thay i.


Basic Control Panel c 5 bn iu khin ch : u ra, tham kho, tham s, sao chp

v li . cc hot ng trong 4 ch u tin c m t trong chng trnh ny. Khi mt

li hoc bo ng xy ra, bng iu khin t ng chuyn sang ch hin th li


hoc bo li. Bn c th thit lp li cc li hoc bo ng u ra hoc ch li (xem chng Diagnostics).

Sau khi in c bt, bng iu khin ch u ra, bn c th chy , dng, thay i hng ,chuyn i qua li gia iu khin cc b v iu khin t xa
v gim st 3 gi tr thc t (ti 1 thi im). thc hin

REM OUTPUT REM

491 .
MENU

Hz

FWD

cc nhim v khc, u tin i ti menu chnh v chn ch thch hp. Lm sao lm nhng nhim v chung ?

PAr

FWD

Bng di y lit k ph bin nhim v, cc ch trong bn c th thc hin chng v s lng trang v cc bc lm nhim v c m t chi tit.
Nhim v Lm th no chuyn i iu khin t xa v iu khin cc b Lm th no khi ng v dng bin tn Lm th no thay i hng quay ca ng c Lm th no duyt qua cc tn hiu gim st Lm th no t tc ,tn s ,hoc torque tham kho Lm th no thay i cc gi tr tham s Lm th no la chn tn hiu gim st Lm th no thit lp nhng li v bo ng Lm th no sao chp thng s t bin tn n bn iu khin Lm th no khi phc li cc thng s t bng iu khin n bin tn kiu
Any Any Any Output Reference Parameter Parameter Output, Fault Copy Copy

trang
64 64 64 65 66 67 68 249 70 70

Control panels

64

ACS550 Users Manual

Lm th no khi ng/ dng li v chuyn i gia iu khin cc b v iu khin t xa Bn c th khi ng ,dng v chuyn i gia iu khin cc b v iu khin t xa trong ch no. chy hoc ngng bin tn, bin tn phi ch cc b.
Step 1. Action thay i gia iu khin t xa (REM c hin th bn tri) v iu khin cc b (LOC hin bn tri),n LOC REM .
LOC OUTPUT

Display

Ch : chuyn mch ch cc b c th v hiu ha vi cc tham s 1606 LOCAL LOCK . Sau khi nhn phm ,mng hnh hin th mt thi gian ngn thng bo LoC, hoc rE, nu thch hp, trc khi tr v mng hnh hin th trc .

491 . LoC

Hz

FWD

LOC

FWD

Thi gian u khi bin tn c cung cp ngun n nm trong s iu khin t xa . (REM) v c kim sot thng qua thit b u cui I/O ca (bin tn v kim sot cc b (LOC)iu khin bin tn bng iu khin tch REM hp nhn LOC kt qu ph thuc vo thi gian bn nhn LOC/REM:
REM

Nu bn thay i phin bn ngay (mng hnh nhp nhy LoC), bin tn dng. t cc tham chiu iu khin cc b theo hng dn trn trang 66. Nu bn nhn phm trong khong 2 giy (c cu ngt khi mng hnh

thay i t LoC n LoC r), bin tn vn tip tc nh trc. cc bn sao bin tn c gi tr dng t xa cho chy/dng tnh trng v tham kho s dng chng nh l cc ci t ch ci t cc b ban u.
Dng bin tn trong ch cc b,nhn Chy bin tn trong ch cc b,nhn . .

Kim tra FWD hoc REV trn dng di cng bt u nhp nhy chm. Kim tra FWD hoc REV trn dng di cng bt u nhp nhy nhanh n dng nhp nhy khi bin tn t n im t.

Lm th no thay i hng quay ca ng c ! Bn c th thay i hng quay ca ng c ch no?..


Step 1. Action Display

Nu bin tn ang s kim sot t xa (REM hin th trn bn tri), thay i LOC sang k cc b nhn LOC . Mng hnh hin th mt thi gian ngn cho thy REM LoC trc khi v mng hnh hin th trc. OUTPUT thay i chiu quay t thun (FWD hin th pha di) n chiu nghch . (REV hin th pha di), hoc ngc li , nhn Ch : Tham s 1003 DIRECTION phi c t n 3 (REQUEST).
LOC OUTPUT

491 . 491 .

Hz

FWD

2.

Hz REV

Control panels

ACS550 Users Manual

65

Ch u ra Trong ch u ra, bn c th:


Gim st cc gi tri thc t ln n 3 nhm 01 OPERATING DATA tn hiu,

1 tn hiu ti mt thi im
Khi ng, dng , thay i hng v chuyn i gia kim sot cc b v kim sot t xa .

Bn chn ch u ra bng cch nhn pha di.

n khi hin th k t cho thy OUTPUT

Mng hnh hin th cho thy gi tr ca 1 tn hiu nhm: 01 OPERATING DATA. n v c hin th pha phi. Trang 64 cho bit lm th no chn ti a 3 tn hiu theo di ch u ra. Bng di y cho thy lm th no xem chng cng mt lc. Lm th no duyt qua trnh gim st
Bc
1.

REM OUTPUT

491 .

Hz

FWD

hot ng Nu nhiu hn mt tn hiu c chn theo di (xem trang 68 ), bn c th duyt chng trong ch u ra Trnh duyt tn hiu thun , nhn phm quay ngc li ,nhn phm nhiu ln. nhiu ln. trnh duyt
REM OUTPUT REM OUTPUT REM OUTPUT

Display

491 . 107 .

Hz

FWD A

05 .

FWD %

FWD

Control panels

66

ACS550 Users Manual

Ch tham kho Trong ch tham kho , bn c th:


t tc , tn s hay momen xon tham kho Khi ng, dng , thay i hng v chuyn i qua li gia k cc b v kim sot t xa.

Lm th no t tc , tn s hay momen xon tham kho


Step 1. Action Display

i n menu chnh bi nhn nu bn ang ch u ra .Nu , khng bng cch nhn nhiu ln n khi bn thy MENU pha di. Nu bin tn ang k t xa(REM hin th trn bn tri),thay i sang kim sot cc b bi nhn REM . Mng hnh hin th thi gian ngn LoC trc LOC khi chuyn i n kim sot cc b .
REM

REM

MENU

PAr PAr rEF


SET

FWD

2.

LOC

MENU

FWD

ch : vi nhm 11 REFERENCE SELECT, bn c th cho php sa i ti liu tham kho trong iu khin t xa (REM)
3.

Nu bng iu khin khng c ch tham kho (rEF khng nhn thy)nhn LOC hoc khi bn thy rEF v sau nhn . by gi mng hnh hin th cho thy gi tr dng tham chiu SET vi gi tr nh hn.
LOC

MENU

FWD Hz

491 . 500 .
SET

FWD

4.

tng gi tr tham kho, nhn gim gi tr tham kho, nhn

. .

LOC

Hz

Gi tr thay i ngay lp tc khi bn nhn phm. N c lu tr trong b nh khng i ca bin tn v t ng phc hi sau khi cng tc ngun .

FWD

Control panels

ACS550 Users Manual

67

Kiu tham s Trong kiu tham s , bn c th:


Xem v gi tr tham s thay i Chn v thay i cc tn hiu c hin th ch u ra Bt u, dng li, thay i hng v chuyn i gia iu khin cc b v kim sot t xa.

Lm th no chn tham s v thay i gi tr ca n


Step 1. Action Display

i n menu chnh bi nhn


khng bng cch nhn

nu bn dang ch u ra

LOC

nhiu ln n khi bn nhn thy MENU pha di.

MENU

rEF PAr -01PAR

FWD

2. nu bng iu khin khng phi l ch thng s mong mun (PAr ko thy), nhn phm LOC hoc n khi thy PAr v sau nhn . Mng hnh hin th s ca mt trong nhng nhm tham chiu.
LOC

MENU

FWD

FWD

3.

Dng phm

tm nhm tham s mong mun.

LOC

-11PAR PAR

FWD

4.

Nhn .

. mng hnh hin th cho thy mt trong nhng tham s trong nhm

LOC

1101 1103
PAR

FWD

5.

Dng phm

tm thng s mong mun.

LOC

FWD

6.

Nhn v gi khong 2 giy n khi mng hnh hin th gi tr ca tham s vi SET bn di ch ra rng vic thay i ca gi tr l by gi l c th.. Ch : khi
v SET c nhn thy,nhn phm ng thi thay i gi tr hin th n gi tr mc nh ca tham s .

LOC

PAR SET FWD

1 2

7.

S dng phm v chn gi tr tham s. khi bn c thay i gi tr tham s SET bt u nhp nhy.

LOC

PAR SET FWD

lu cc gi tr tham s hin th , nhn hy cc gi tr mi v gi nguyn bn , nhn

. .

LOC

1103
PAR

FWD

Control panels

68

ACS550 Users Manual

Lm th no chn tn hiu gim st


Step 1. Action Display
LOC

Bn c th chn nhng tn hiu c theo di ch u ra v lm th no chng c hin th vi nhm 34 PANEL DISPLAY thng s. xem trang 49 c hng dn chi tit v thay i gi tr tham s. Theo mc nh, hin th cho thy 3 tn hiu. nhng tn hiu mc nh c th xem (xem trang 65) ph thuc gi tr tham s 9902 APPLIC MACRO: vi macro c gi tr mc nh ca tham s 9904 MOTOR CTRL MODE l 1 (VECTOR:SPEED)mc nh tn hiu 1 l 0102 SPEED, nu khng 0103 OUTPUT FREQ mc nh tn hiu 2 v 3 lun 0104 CURRENT v 0105 TORQUE,tng ng . Thay i cc tn hiu mc nh , chn t nhm 01: OPERATING DATA n ba tn hiu c duyt . Tn hiu 1: thay i gi tr ca tham s 3401 SIGNAL1 PARAM n ch s ca cc tham s tn hiu trong nhm 01 OPERATING DATA (= s ca tham s m khng c s 0 u ), e.g. 105 tham s bin php 0105 TORQUE. Gi tr 100 c ngha l tn hiu khng c hin th . Lp li cho tn hiu 2 (3408 SIGNAL2 PARAM) v 3 (3415 SIGNAL3. PARAM). V d, nu 3401 = 0 v 3415 = 0, duyt qua b v hiu ha v ch c cc tn hiu theo quy nh ca 3408 c hin th . Nu c 3 tham s c t 0, i.e. khng c tn hiu c chn theo di, cc bng iu khin hin th vn bn n.A.

PAR SET FWD LOC

103 104 105

PAR SET FWD LOC

PAR SET FWD

2.

Xc nh v tr im thp phn, hoc s dng v tr du thp phn v n v ca ngun tn hiu [ci t (9 (DIRECT)]. th tham s khng c sn cho Basic Operation Panel. Chi tit ,xem tham s 3404. Tn hiu 1: tham s 3404 OUTPUT1 DSP FORM Tn hiu 2: tham s 3411 OUTPUT2 DSP FORM Tn hiu 3: tham s 3418 OUTPUT3 DSP FORM.

LOC

PAR SET FWD

9 3

3.

Chn cc n v s c hin th cho cc tn hiu. iu ny khng c tc dng nu tham s 3404/3411/3418 c t n 9 (DIRECT). Chi tit, xem tham s 3405. Tn hiu 1: tham s 3405 OUTPUT1 UNIT Tn hiu 2: tham s 3412 OUTPUT2 UNIT Tn hiu 3: tham s 3419 OUTPUT3 UNIT.

LOC

PAR SET FWD

4.

Chn t l cho cc tn hiu bng cch xc nh gi tr nh nht v ln nht iu ny khng c tc dng nu tham s 3404/3411/3418 c t 9 (DIRECT). Chi tit, xem tham s 3406 v 3407. Tn hiu 1: tham s 3406 OUTPUT1 MIN v 3407 OUTPUT1 MAX Tn hiu 2: tham s 3413 OUTPUT2 MIN v 3414 OUTPUT2 MAX Tn hiu 3: tham s 3420 OUTPUT3 MIN v 3421 OUTPUT3 MAX.

LOC

PAR SET FWD LOC

00 .

Hz

5000 .

Hz

PAR SET FWD

Control panels

ACS550 Users Manual

69

Hnh thc sao chp

Basic Control Panel c th lu tr tp hp y tham s ca bin tn v ti a s dng 3 ci t ca thng s bin tn vo bng iu khin. B nh bng iu khin l khng d thay i. Trong ch copy, bn c th lm nh sau : Copy tt c cc tham s t bin tn n bng iu khin (uL Upload). iu ny bao gm xc nh gi tr ci t ca cc thng s v ci t sn (khng iu chnh bi ngi dng) cc tham s nh c to ra bi ID Run . Khi phc ton b thng s t bng iu khin n bin tn (dL A Download All). Vit tt c cc thng s ny , bao gm cc thng s ng c
khng s dng , n bin tn. n khng bao gm nhng ci t s dng ca b tham s

Ch : ch s dng chc nng ny khi phc li bin tn, hoc truyn tham s cho h thng trng vi h thng ban u. copy mt tham s ci t mt phn t bng iu khin vo mt bin tn (dL P ti v mt phn). Mt phn ci t khng bao gm cc ci t s dng,cc thng s bn trong ng c, tham s 99059909, 1605, 1607, 5201, khng bao gm nhm 51 EXT COMM MODULE v thng s 53 EFB PROTOCOL. B ngun v bin tn mc tiu v kch c ng c khng cn phi ging nhau.
Sao chp USER S1 tham s t bng iu khin n bin tn (dL u1 Download

User Set 1). Tp hp ci t gm nhm 99 START-UP DATA tham s v thng s ni b ng c . Chc nng ny ch hin th trn menu khi dng Set 1 c lu trc khi s dng tham s 9902 APPLIC MACRO (xem phn User macros trn trang 94) v sau ti ln bng .
Copy USERS2 tham s t bng n bin tn (dL u2 Download

User Set 2). As dL u1 Download User Set 1 trn


Copy USER S3 tham s t bng n bin tn (dL u3 Download

User Set 3). As dL u1 Download User Set 1 trn chy,dng, thay i hng v chuyn i gia iu khin cc b v iu khin t xa.

Control panels

70

ACS550 Users Manual

L th no upload v download cc tham s cho ti ln v ti xung chc nng c sn , xem trn.


Step 1. Action Display
LOC

i n Main menu bng cch nhn nu bn ang ch ng ra, nu khng bi nhn nhiu ln cho ti khi bn thyMENU pha di. Nu bng iu khin khng c ch sao chp(CoPY0 thy),nhn hoc n khi bn nhn thy CoPY.
nhn .

MENU

PAr

FWD

2.

LOC

MENU LOC

CoPY uL dL A

FWD

dL u1
MENU MENU

FWD

3.

ti ln tt c tham s (bao gm c ci t s dng) t bin tn n bng LOC v . iu khin, bc tiuLvi phm

FWD % FWD

Nhn trong thi gian chuyn giao, mng hnh hin th cho thy tnh trng chuyn giao t l hon thnh.
thc hin ti v, bc n hot ng thch hp ( y dL A, v . ti v t c, c s dng lm v d) vi cc phm

LOC

uL 50
MENU

LOC

FWD % FWD

Nhn . trong thi gian chuyn giao, mng hnh hin th cho thy tnh trng chuyn giao t l hon thnh.

LOC

dL 50

M s bo ng Basic Control Panel Ngoi cc li v bo ng to ra bi bin tn (xem chng Diagnostics), Basic Control Panel cho bit bo ng bng iu khin vi m s l A5xxx.. Xem chn Alarm codes (Basic Control Panel) trn trang 253 cho danh sch cc m s bo ng v m t.

Control panels

ACS550 Users Manual

71

Application macros
Macro thay i mt nhm cc tham s mi, cc gi tr c xc nh trc. s dng macro gim thiu s cn thit phi chnh sa bng tay cc thng s. Chn mt macro ci t tt c cc thng s khc mc nh gi tr ca chng , ngoi tr : nhm 99: START-UP DATA tham s (ngoi tr tham s 9904) 1602 PARAMETER LOCK 1607 PARAM SAVE 3018 COMM FAULT FUNC v 3019 COMM FAULT TIME 9802 COMM PROT SEL nhm 50: ENCODER nhm 53: EFB PROTOCOL tham s nhm 29: MAINTENANCE TRIG tham s. Sau khi chn mt macro, bn c th thay i tham s b sung bng tay vi bng iu khin. Bn kch hot ng dng macro bng cch thit lp gi tr ca tham s 9902 APPLIC MACRO. Theo mc nh, 1, ABB STANDARD, l macro c kch hot. Nhng phn sau y m t tng ng dng macro v cung cp mt v d kt ni cho mi macro . Phn cui cng trong chng ny, Macro default values for parameters, danh sch cc tham s thay i macro v cc gi tr mc nh to sn theo tng macro . .

Application macros

72

ACS550 Users Manual

ABB Standard macro


y l macro mc nh. N cung cp mt mc ch chung, cu hnh 2-wire I/O, vi ba (3) tc khng i. Thng s gi tr c mc nh gi tr trong phn Complete parameter list trn trang 85.
V d kt ni:
X1
110 kohm 1

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc)


tn s tham s ngoi 1:

010 V1

u vo tng t dng in chung in p chun 10 V DC khng s dng u vo tng t dng in chung


tn s u ra: 020 mA dng in u ra: 020 mA

u ra tng t dng in chung u ra in p ph : +24 V DC u ra in p ph chung u vo s chung cho tt c


khi ng/dng: kch hot n khi ng thun/nghch: kch hot o ngc hng quay

chn tc khng i 2 chn tc khng i 2 chn gia hai dc: kch hot chn cp dc 2nd acc/dec Khng s dng
u ra Relay 1, lp trnh xc nh hot ng : Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng : ang chy =>22 kt ni n 24 u ra Relay 3, lp trnh xc nh hot ng : Li (-1) =>25 kt ni n 27 (li => 25 kt ni n 26) Note 1. tham chiu ngoi c s dng nh mt tc tham chiu nu ch vector c chn. Note 2. m: 0 = m, 1 = kt ni DI3 0 1 0 1 DI4 0 0 1 1 u ra Tham chiu thng qua AI1 Tc khng i 1 (1202) Tc khng i 2 (1203) Tc khng i 3 (1204) Jumper setting J1
ON ON

Cc u vo tn hiu Tham chiu tng t (AI1) Khi ng, dng v hng (DI1,2) Chn tc khng i (DI3,4) Cp dc (1 of 2) chn (DI5)

Cc u ra tn hiu u ra tng t AO1: tn s u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12

AI1: 010 V AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Application macros

ACS550 Users Manual

73

3-wire macro
Macro ny c s dng khi bin tn c iu khin bng cch s dng nt nhn . N cung cp ba tc khng i. kch hot ,thit lp gi tr ca tham s 9902 n 2 (3-WIRE) Ch : khi cc u vo dng li (DI2) l v hiu ha (khng c u vo), bng iu khin khi ng v nt dng li mt tc dng.
V d kt ni:
X1
110 kohm 1

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc)

tc tham s ngoi 1: 010 V

u vo tng t dng in chung in p chun 10 V DC


Khng s dng

u vo tng t dng in chung


u ra tc ng c: 020 mA dng in u ra: 0 20 mA

u ra tng t dng in chung u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c


khi ng: kch hot tc thi vi DI2 kch hot khi ng bin tn dng: kh kch hot tc thi dng bin tn . thun/nghch: kch hot o ngc hng quay .

chn tc khng i 1 chn tc khng i 1


Khng s dng

u ra Relay 1, lp trnh xc nh hot ng:: Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng: ang chy =>22 kt ni n 24 Relay output 3, programmable xc nh hot ng: li (-1) =>25 kt ni n 27 li => 25 kt ni n 26)

Note 1. Code: 0 = open, 1 = connected DI4 0 1 0 1 DI5 0 0 1 1 Output Reference through AI1 CONST SPEED 1 (1202) CONST SPEED 2 (1203) CONST SPEED 3 (1204)

Cc u vo tn hiu Tham chiu tng t (AI1) Khi ng, dng v hng (DI1,2,3) Chn tc khng i (DI4,5)

Cc u ra tn hiu u ra tng t AO1: tc u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12 ON

Jumper setting J1 AI1: 010 V


ON

AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Application macros

74

ACS550 Users Manual

Alternate macro
Macro ny cung cp I/O cu hnh thch nghi vi mt chui cc DI tn hiu iu khin c s dng khi bin tn iu khin xen k chiu quay ng c. kch hot, t gi tr ca tham s 9902 n 3 (ALTERNATE).
V d kt ni:
110 kohm

X1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc

tc tham chiu ngoi 1: 010 V

u vo tng t dng in chung in p chun 10 V DC


Khng s dng

u vo tng t dng in chung


u ra tc ng c: 020 mA dng in u ra: 0 20 mA

u ra tng t dng in chung u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c khi ng thun: nu trng thi DI1 ging nh DI2, bin tn dng
khi ng nghch

chn tc khng i 1 chn tc khng i 1


chn cp dc: kch hot chn cp dc 2nd acc/dec cho php chy: kh kch hot bin tn lun lun dng u ra Relay 1, lp trnh xc nh hot ng: Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng: ang chy =>22 kt ni n 24 u ra Relay 3, lp trnh xc nh hot ng: li (-1) =>25 kt ni n 27 (li => 25 kt ni n 26)

Note 1. Code: 0 = m, 1 = kt ni DI3 0 1 0 1 DI4 0 0 1 1 Output Tham chiu thng qua AI1 CONST SPEED 1 (1202) CONST SPEED 2 (1203) CONST SPEED 3 (1204)

Cc u vo tn hiu Tham chiu tng t (AI1) Khi ng, dng v hng (DI1,2) Chn tc khng i (DI3,4) Chn cp dc 1/2 (DI5) Cho php chy (DI6)

Cc u ra tn hiu u ra tng t AO1: tc u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12 ON

Jumper setting J1 AI1: 010 V


ON

AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Application macros

ACS550 Users Manual

75

Motor Potentiometer macro


Macro ny cung cp giao din hu hiu cho cc PLC thay i tc ng c ch dng tn hiu s. kch hot macro, t gi tr ca tham s 9902
n 4 (MOTOR POT). V d kt ni:
X1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc) Khng s dng u vo tng t dng in chung in p chun 10 V DC Khng s dng u vo tng t dng in chung
u ra tc ng c: 020 mA u ra dng in: 0 20 mA

u ra tng t dng in chung u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c


khi ng/dng: kch hot khi ng bin tn. thun/nghch: kch hot o ngc hng quay tham chiu ln: kch hot lm tng tham chiu1 tham chiu xung: kch hot lm gim tham chiu 1 tc khng i 1: 1202 cho php chy: kh kch hot bin tn lun lun dng. u ra Relay 1, lp trnh xc nh hot ng: Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng: ang chy =>22 kt ni n 24 u ra Relay 3, lp trnh xc nh hot ng: li (-1) =>25 kt ni n 27 (li => 25 kt ni n 26) Ch 1. cho DI3 v DI4: nu c hai ang hot ng hoc khng hot ng tc tham chiu l khng i. tham chiu tc hin ti c lu tr trong thi gian dng hoc mt in . Ch 2. ci t dc thi gian vi thi gian tng tc v gim tc 2 (thng s 2205 v 2206).

Cc u vo tn hiu Khi ng, dng v hng (DI1,2) Tham chiu ln/xung (DI3,4) Chn tc khng i (DI5) Cho php chy (DI6)

Cc u ra tn hiu u ra tng t AO1: tc u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12 ON

Jumper setting J1 AI1: 010 V


ON

AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Application macros

76

ACS550 Users Manual

Hand-Auto macro
Macro ny cung cp mt cu hnh I/O l chun c s dng trong cc ng dng HVAC. kch hot , t gi tr ca tham s 9902 n 5 (HAND/AUTO)
Ch : thng s 2108 START INHIBIT phi trong ci t mc nh, 0 (OFF). V d kt ni:
X1
110 kohm 1

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tham chiu ngoi 1: 010 V (Hand Control)

tn hiu cp l chn (li lc)

u vo tng t dng in chung in p chun 10 V DC u vo tng t dng in chung


u ra tc ng c: 020 mA u ra dng in: 020 mA

tham chiu ngoi 2: 020 mA (Auto Control)

u ra tng t dng in chung u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c


khi ng/dng (Hand): kch hot khi ng bin tn thun/nghch (Hand): kch hot o ngc hng quay chn EXT1/EXT2: kch hot chn iu khin auto cho php chy: kh kch hot bin tn lun lun dng thun/nghch (Auto): kch hot o ngc hng quay khi ng/dng (Auto): kch hot khi ng bin tn u ra Relay 1, lp trnh xc nh hot ng:: Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng:: ang chy =>22 kt ni n 24 u ra Relay 3, lp trnh xc nh hot ng:: Fault (-1) =>25 connected to 27 (li => 25 kt ni n 26)

Ch 1. Cm bin cn c h tr. Xem hng dn ca nh sn xut. Mt v d kt ni ca mt b cm bin hai dy c hin th trn trang 80. Jumper setting J1
ON ON

Cc u vo tn hiu Hai tham chiu tng t (AI1, 2) khi ng/dng hand/auto (DI1, 6) hng hand/auto (DI2, 5) chn v tr kim sot (DI3) cho php chy (DI4)

Cc u ra tn hiu u ra tng t AO1: tc u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12

AI1: 010 V AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Application macros

ACS550 Users Manual

77

PID Control macro


Macro ny cung cp cc thit lp thng s cho h thng iu khin vng lp knh nh kim sot p sut, kim sot lu lng , v.v. kch hot macro,t gi tr tham s 9902 n 6 (PID CONTROL). Ch : tham s 2108 START INHIBIT phi trong thit lp mc nh 0 (OFF).
V d kt ni:
X1
110 kohm 1

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc)

tham chiu ngoi. 1 (Manual) hoc tham chiu. 2 (PID): 0 10 V1

u vo tng t dng in chung ch 1. in p chun 10 V DC Manual: 010V => tc tham chiu


Tn hiu thc t (PID): 420 mA

u vo tng t dng in chung


u ra tc ng c: 020 mA u ra dng in: 020 mA

PID: 010V => 0 100% im t PID

u vo tng t dng in chung ch 3. u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c

cm bin cn c h tr . xem hng dn ca nh sn xut. mt kt ni v d ca mt cm bin hai dy c hin th trn trang 80.

khi ng/dng (Hand): kch hot khi ng bin tn chn EXT1/EXT2: kch hot chn iu khin PID tc khng i 1: (khng s dng trong iu khin PID)2 tc khng i 2: (khng s dng trong iu khin PID)2 cho php chy: kh kch hot bin tn lun lun dng khi ng/dng (PID): kch hot khi ng bin tn u ra Relay 1, lp trnh xc nh hot ng: Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng: ang chy =>22 kt ni n 24 u ra Relay 3, lp trnh xc nh hot ng: Fault (-1) =>25 connected to 27 (li => 25 kt ni n 26)

Ch 2. m : 0 = m, 1 = kt ni DI3 0 1 0 1 DI4 0 0 1 1 u ra Tham chiu thng qua AI1 CONST SPEED 1 (1202) CONST SPEED 2 (1203) CONST SPEED 3 (1204)

Cc u vo tn hiu Tham chiu tng t (AI1) Gi tr thc t (AI2) khi ng/dng hand/PID (DI1, 6) chn EXT1/EXT2 (DI2) chn tc khng i (DI3, 4) cho php chy (DI5)

Cc u ra tn hiu u ra tng t AO1: tc u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12 ON

Jumper setting J1 AI1: 010 V


ON

AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Ch : s dng cc chuyn i sau y theo trnh t: 1. EXT1/EXT2 2. cho php chy 3. khi ng.

Application macros

78

ACS550 Users Manual

PFC macro
macro cung cp thit lp thng s cho ng dng kim sot bm v qut (PFC). kch hot, thit lp gi tr ca tham s 9902 n 7 (PFC CONTROL).

Ch : tham s 2108 START INHIBIT phi trong thit lp mc nh 0 (OFF).


V d kt ni :
110 kohm

X1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc)

tham chiu ngoi. 1 (Manual) hoc ngoi. 2 (PID/PFC): 010 V1

u vo tng t dng in chung in p chun 10 V DC


Tn hiu thc t (PID): 420 mA

u vo tng t dng in chung

u ra tn s: 020 mA Thc t 1 (PI iu khin gi tr thc t): 0(4) 20 mA

ch 1. Manual: 010V => 050 Hz PID/PFC: 010V => 0100% im t PID

u vo tng t dng in chung u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c


khi ng/dng (Manual): kch hot khi ng bin tn cho php chy: kh kch hot bin tn lun lun dng chn EXT1/EXT2: kch hot chn iu khin PFC kha lin ng: kh kch hot bin tn lun lun dng kha lin ng: kh kch hot dng tc khng i ng c khi ng/dng (PFC): kch hot khi ng bin tn u ra Relay 1, lp trnh xc nh hot ng: Sn sng =>19 kt ni n 21 ch 2. Cm bin cn phi c h tr. xem hng dn ca nh sn xut. mt kt ni v d ca mt cm bin hai dy c hin th trn trang 80.

u ra Relay 2, lp trnh xc nh hot ng: ang chy =>22 kt ni n 24 (li => 22 kt ni n 23) u ra Relay 3, lp trnh xc nh hot ng: bt ng c ph =>25 kt ni n 27 Cc u ra tn hiu u ra tng t AO1: tn s u ra tng t AO2: thc t 1 u ra Relay 1: ang chy u ra Relay 2: li (-1) u ra Relay 3: ng c ph ON
12 ON ON

Cc u vo tn hiu Tham chiu tng t v thc t (AI1, 2) khi ng/dng manual/PFC (DI1, 6) cho php chy (DI2) chn EXT1/EXT2 (DI3) kha lin ng (DI4, 5)

Jumper setting J1 AI1: 010 V AI2: 0(4)20 mA

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Ch : s dng cc chuyn i sau y theo trnh t: 1. EXT1/EXT2 2. cho php chy 3. khi ng.

Application macros

ACS550 Users Manual

79

Torque Control macro


Macro ny cung cp cc thit lp thng s cho cc ng dng t c yu cu kim sot momen xon ca ng c. Kim sot ny cng c th c chuyn sang kim sot tc . kch hot , t gi tr ca tham s 9902 n 8 (TORQUE CTRL).
V d kt ni:
X1
110 kohm 1

2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

SCR AI1 AGND 10V AI2 AGND AO1 AO2 AGND 24V GND DCOM DI1 DI2 DI3 DI4 DI5 DI6 RO1C RO1A RO1B RO2C RO2A RO2B RO3C RO3A RO3B

tn hiu cp l chn (li lc)

tc tham chiu ngoi 1: 010 V

u vo tng t dng in chung in p chun 10 V DC


momen xon tham chiu ngoi: 420 mA

u vo tng t dng in chung


u ra tc ng c: 020 mA u ra dng in: 020 mA ch 1. quay ngc hng trong kim sot tc . hng moen xon ngc trong kim sot momen xon.

u vo tng t dng in chung u ra in p ph +24 V DC u ra in p ph chung u vo s chung cho tt c

khi ng/dng : kch hot khi ng bin tn thun/nghch : kch hot o ngc hng quay 1 kim sot tc /momen xon: kch hot chn kim sot momen xon tc khng i 1: 1202 chn cp dc: kch hot n chn cp dc 2nd acc/dec cho php chy: kh kch hot bin tn lun lun dng u ra Relay 1, lp trnh xc nh hot ng: Sn sng =>19 kt ni n 21 u ra Relay 2, lp trnh xc nh hot ng : ang chy =>22 kt ni n 24 u ra Relay 3, lp trnh xc nh hot ng: Fault (-1) =>25 connected to 27 (li => 25 kt ni n 26) Cc u ra tn hiu u ra tng t AO1: tc u ra tng t AO2: dng in u ra Relay 1: sn sng u ra Relay 2: ang chy u ra Relay 3: li (-1)
12 ON ON

ch 2.. Cm bin cn phi c h tr. Xem hng dn ca nh sn xut.. Mt kt ni v d ca mt cm bin hai dy c hin th trn trang 80

Cc u vo tn hiu Hai tham chiu tng t (AI1, 2) khi ng/dng v hng (DI1, 2) chn tc khng i (DI4) chn gia hai cp dc 1/2 (DI5) cho php chy (DI6)

Jumper setting J1 AI1: 010 V AI2: 0(4)20 mA

kim sot tc /momen xon (DI3)

or J1
ON

AI1: 010 V AI2: 0(4)20 mA

Application macros

80

ACS550 Users Manual

Connection example of a two-wire sensor


Nhiu ng dng s dng qu trnh PI(D) v cn mt tnh hiu phn hi t qu trnh ny. Tn hiu phn hi thng c kt ni vi u vo tng t 2 (AI2). S ni dy macro trong chng ny cho thy cc kt ni khi mt cm bin c s dng cp ngun ring . hnh di y cho mt v d v cch kt ni s dng mt cm bin hai dy .
420 mA I X1 / control board 5 AI2 o qu trnh gi tr thc t , 6 AGND 0(4) 20 mA, Rin = 100 ohm X1 / control board 10 +24 V u ra in p ph, khng b c lp , 11 GND 24 V DC, 250 mA

Lu : cm bin ny cung cp thng qua u ra dng in. tn hiu u ra phi c 420 mA, khng phi 020 m A.

Application macros

ACS550 Users Manual

81

User parameter sets


Ngoi cc ng dng macro tiu chun , n c th to ra hai macro ngi dng
b tham s vo trong b nh thng xuyn ca n v ti n thi gian sau . Mt tp hp tham s ngi dng bao gm cc tham s ngi dng, bao gm c nhm 99: STARTUP DATA, v kt qu ca vic xc nh ng c. Cc bng tham kho cng c lu

nu macro c lu v np trong ch kim sot cc b. Thit lp iu khin t xa c lu vo cc macro ngi dng , nhng cc thit lp kim sot cc b th khng.
.

Cc bc di y cho thy lm th no to ra v thu hi user macro 1. th tc cho hai Macro ngi dng l ging nhau, ch c tham s 9902 c gi tr khc..
lu User Parameter Set 1: iu chnh cc thng s . Thc hin xc nh ng c nu n cn thit trong ng dng nhng n khng c nu ra. Lu cc ci t thng s v kt qu ca vic xc nh ng c n b nh thng trc bng cch thay i tham s 9902 n -1 (USER S1 SAVE). Nhn
SAVE

(Assistant Control Panel) hoc

MENU ENTER

(Basic Control Panel).

n ti User Parameter Set 1: Thay i tham s 9902 n 0 (USER S1 LOAD). Nhn


SAVE

(Assistant Control Panel) hoc

MENU ENTER

(Basic Control Panel) ti.

Cc macro ngi dng cng c th c chuyn qua u vo s (xem tham s


1605).

Ch : User macro ti phc hi thng s ci t bao gm c nhm nhm 99: START -UP DATA v kt qu ca vic xc nh ng c.Kim tra ci t tng ng vi ng c s dng. Gi : v d ngi s dng c th chuyn i bin tn vi hai ng c m khng phi iu chnh cc thng s ng c v lp li vic xc nh ng c l thay i. Ngi s dng ch cn iu chnh cc thit lp v thc hin vic xc nh ng c mt ln cho mi ng c v sau lu d liu nh ba macro s dng . Khi thay i cc ng c, ch c macro s dng tng ng cc nhu cu c np , v bin tn sn sng hot ng .

Application macros

82

ACS550 Users Manual

Gi tr mc nh Macro cho tham s


Gi tr mc nh c lit k trong phn Complete parameter list trn trang 85. Thay i t macro mc nh (ABB Standard), l, chnh sa gi tr ca tham s 9902, thay i gi tr thng s mc nh nh quy nh trong cc bng di y . Ch : c hai b gi tr bi mc nh cho cu hnh 50 Hz/ IEC ph hp (ACS550-01) v 60 Hz/NEMA ph hp (ACS550-U1). ACS550-01

Parameter

Hand3-wire Alternate Motor auto Potentio Standard meter ABB 1 3 2 0 3 0 1 2 9 0 1 2 3 103 50 104 0 0 50 5 103 103 10 60 1 60 0 2 1 4 0 3 0 1 2 10 0 1 2 3 102 50 104 0 0 50 0 102 102 10 60 1 60 0 3 1 9 0 3 0 1 2 9 0 1 2 3 102 50 104 0 6 50 5 102 102 10 60 1 60 0 4 1 2 0 3 0 12 2 5 0 1 2 3 102 50 104 0 6 50 0 102 102 10 60 1 60 0 5 1 2 7 3 3 1 2 0 20 1 2 3 102 50 104 0 4 50 0 102 102 10 60 1 60 0

PID PFC Torque Control Control Control

9902 9904 1001 1002 1003 1102 1103 1106 1201 1304 1401 1402 1403 1501 1503 1507 1510 1601 2008 2201 3201 3401 4001 4002 4101 4102 8123

APPLIC MACRO MOTOR CTRL MODE EXT1 COMMANDS EXT2 COMMANDS DIRECTION EXT1/ EXT2 SEL REF1 SELECT REF2 SELECT CONST SPEED SEL MINIMUM AI2 RELAY OUTPUT RELAY OUTPUT 2 RELAY OUTPUT 3 AO1 CONTENT SEL AO1 CONTENT MAX AO2 CONTENT SEL MINIMUM AO2 RUN ENABLE MAXIMUM FREQ ACC/DEC

1/2 SEL

SUPERV 1 PARAM SIGNAL1 PARAM GAIN INTEGRATION TIME GAIN INTEGRATION TIME PFC ENABLE

6 1 1 6 1 2 1 19 9 20 1 2 3 102 50 104 0 5 50 0 102 102 10 60 1 60 0

7 3 1 6 1 3 1 19 0 20 2 3 31 103 52 130 4 2 52 0 103 103 25 3 2,5 3 1

8 2 2 2 3 3 1 2 4 20 1 2 3 102 50 104 0 6 50 5 102 102 10 60 1 60 0

Application macros

ACS550 Users Manual

83

ACS550-U1

Parameter

ABB Standard

3-wire Alternate Motor Potenti ometer 2 1 4 0 3 0 1 2 10 0 1 2 3 102 60 104 0 0 60 0 102 102 10 60 1 60 0 3 1 9 0 3 0 1 2 9 0 1 2 3 102 60 104 0 6 60 5 102 102 10 60 1 60 0 4 1 2 0 3 0 12 2 5 0 1 2 3 102 60 104 0 6 60 0 102 102 10 60 1 60 0

Hand- PID PFC Torque auto Control Control Control

9902 9904 1001 1002 1003 1102 1103 1106 1201 1304 1401 1402 1403 1501 1503 1507 1510 1601 2008 2201 3201 3401 4001 4002 4101 4102 8123

APPLIC MACRO MOTOR CTRL MODE EXT1 COMMANDS EXT2 COMMANDS DIRECTION EXT1/ EXT2 SEL REF1 SELECT REF2 SELECT CONST SPEED SEL MINIMUM AI2 RELAY OUTPUT RELAY OUTPUT 2 RELAY OUTPUT 3 AO1 CONTENT SEL AO1 CONTENT MAX AO2 CONTENT SEL MINIMUM AO2 RUN ENABLE MAXIMUM FREQ ACC/DEC

1/2 SEL

SUPERV 1 PARAM SIGNAL1 PARAM GAIN INTEGRATION TIME GAIN INTEGRATION TIME PFC ENABLE

1 3 2 0 3 0 1 2 9 0 1 2 3 103 60 104 0 0 60 5 103 103 10 60 1 60 0

5 1 2 7 3 3 1 2 0 20 1 2 3 102 60 104 0 4 60 0 102 102 10 60 1 60 0

6 1 1 6 1 2 1 19 9 20 1 2 3 102 60 104 0 5 60 0 102 102 10 60 1 60 0

7 3 1 6 1 3 1 19 0 20 2 3 31 103 62 130 4 2 62 0 103 103 25 3 2,5 3 1

8 2 2 2 3 3 1 2 4 20 1 2 3 102 60 104 0 6 60 5 102 102 10 60 1 60 0

Application macros

84

ACS550 Users Manual

Application macros

ACS550 Users Manual

85

Parameters

B sung danh sch tham s


Bng di y lit k tt c cc thng s. bng tiu vit tc l : S = tham s c sa i ch khi dng bin tn. User = khong nhp cc gi tr tham s mong mun Mt s gi tr ph thuc trn cu to nh ch bo trong bng bi 01: hoc U1:. Hy tham kho loi k hiu trn bin tn, cho v d ACS550-01..
Code 9901 9902 9904 9905 Name Range 015 / 03 -38, 31 1 = VECTOR:SPEED, 2 = VECTOR:TORQUE, 1 3 = SCALAR:FREQ 115345 V 01: 200600 V / U1: 230690 V U1: 288862 V 9906 9907 9908 9909 9910 0101 0102 0103 0104 0105 0106 0107 0109 0110 0111 0112 0113 0114 0115 0116 0118 MOTOR NOM CURR MOTOR NOM FREQ MOTOR NOM SPEED 0.2 I2hd 2.0 I2hd 10.0.0500.0 Hz 5030000 rpm 1V 0.1 A 0.1 Hz 1 rpm 01: 0.1 kW / U1: 0.1 hp ID RUN SPEED& DIR SPEED OUTPUT FREQ CURRENT TORQUE POWER DC BUS VOLTAGE OUTPUT VOLTAGE DRIVE TEMP 1 EXTERNAL REF 2 EXTERNAL REF CTRL LOCATION RUN TIME (R) KWH COUNTER (R) APPL BLK OUTPUT DI 1-3 STATUS 0 = OFF/IDMAGN, 1 = ON -3000030000 rpm 030000 rpm 0.0500.0 Hz 0.02.0 I2hd -200.0200.0% -2.02.0 Phd 02.5 VdN 02.0 VdN 0.0150.0 030000 rpm / 0.0500.0 Hz 0.0100.0% (0.0600.0% for torque) 0.1% 0 = LOCAL, 1 = EXT1, 2 = EXT2 09999 h 09999 kWh 0.0100.0% (0.0600.0% for torque) 0.1% 000111 (07 decimal) 1 1 1h 1 kWh 1 1 rpm 1 rpm 0.1 Hz 0.1 A 0.1% 0.1 kW 1V 1V 0.1 1 rpm / 0.1 Hz 0h 0 (OFF/IDMAGN) ! Group 01: OPERATING DATA 1V 1V Resolution 1 1 Default 0 (ENGLISH) 1 (ABB STANDARD) 3 (SCALAR:FREQ) 230 V 01: 400 V / U1: 460 V U1: 575 V 1.0 I2hd 01: 50.0 Hz / U1: 60.0 Hz Size dependent 1.0 Phd ! ! MOTOR NOM POWER 0.23.0 Phd ! ! ! ! ! ! ! User S Group 99: START-UP DATA LANGUAGE APPLIC MACRO MOTOR CTRL MODE MOTOR NOM VOLT

Parameters

86

ACS550 Users Manual

Code 0119 0120 0121 0122 0123 0124 0125 0126 0127 0128 0129 0130 0131 0132 0133 0134 0135 0136 0137 0138 0139 0140 0141 0142 0143 0144 0145

Name
DI AI AI

Range 000111 (07 decimal) 0.0100.0% 0.0100.0% 000111 (07 decimal) 000111 (07 decimal) 0.020.0 mA 0.020.0 mA -1000.01000.0% -100.0100.0% Unit and scale defined by par. 4006/ 4106 and 4007/4107 Unit and scale defined by par. 4206 and 4207 Unit and scale defined by par. 4006/ 4106 and 4007/4107 Unit and scale defined by par. 4206 and 4207 Unit and scale defined by par. 4006/ 4106 and 4007/4107 Unit and scale defined by par. 4206 and 4207 065535 -32768+32767 -32768+32767 0.00499.99 kh 09999 MWh 065535 Mrev 065535 days 00:00:0023:59:58 Par. 3501 = 13: -10200 C Par. 3501 = 4: 05000 ohm Par. 3501 = 56: 01 032768 -32768 +32767 0 = NOT DETECTED, 1 = DETECTED -20.0150.0 C 0.0999.9 kWh 09999 MWh 1 2 -32768 +32767 -32768 +32767 -

Resolution 1 0.1% 0.1% 1 1 0.1 mA 0.1 mA 0.1% 0.1% -

Default -

User S

4-6 STATUS 1 2 1-3 STATUS 4-6 STATUS 1 2 1 OUTPUT 2 OUTPUT 1 SETPNT 2 SETPNT 1 FBK 2 FBK 1 DEVIATION 2 DEVIATION

RO RO AO AO PID PID PID

PID

PID

PID

PID

PID

COMM RO WORD COMM VALUE COMM VALUE PROCESS VAR PROCESS VAR PROCESS VAR RUN TIME MWH COUNTER REVOLUTION CNTR DRIVE ON TIME HI DRIVE ON TIME LO MOTOR TEMP

1 1 1 1 1 1 0.01 kh 1 MWh 1 Mrev 1 day 1=2s 1

0 0 0

1 2 1 2 3

0.00 kh 0 0 0 -

0146 0147 0148 0150 0151 0152 0158 0159 0301 0302 0303

MECH ANGLE MECH REVS Z PLS DETECTED CB TEMP INPUT KWH (R) INPUT MWH PID COMM VALUE PID COMM VALUE

1 1 1 (DETECTED) 1.0 C 1.0 kWh 1 MWh 1 1 -

Group 03: FB ACTUAL SIGNALS


FB CMD WORD FB CMD WORD FB STS WORD

1 2 1

Parameters

ACS550 Users Manual

87

Code 0304 0305 0306 0307 0308 0309 0401 0402 0403 0404 0405 0406 0407 0408 0409 0410 0411 0412 0413 1001 1002 1003 1004 1101 1102 1103 1104 1105 1106 1107 1108 1201 1202 1203 1204 1205

Name
FB STS WORD FAULT WORD FAULT WORD FAULT WORD ALARM WORD ALARM WORD

Range 2 1 2 3 1 2 Fault codes (panel displays as text) 1 2 Time hh.mm.ss -32768+32767 -3276.8+3276.7 0.06553.5 0.06553.5 -3276.8+3276.7 00xFFFF (hex) 000111 (07 decimal) 000111 (07 decimal) 1 2 As par. 0401 As par. 0401 014 014 1 = FORWARD, 2 = REVERSE, 3 = REQUEST -66 1 = REF1(Hz/rpm), 2 = REF2(%) -612 017, 2021 0.0500.0 Hz / 030000 rpm 0.0500.0 Hz / 030000 rpm 017, 1921 0.0100.0% (0.0600.0% for torque) 0.1% 0.0100.0% (0.0600.0% for torque) 0.1% -14 19 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz

Resolution 1 1 1 1 1 1 1 2s 1 rpm 0.1 Hz 0.1 V 0.1 A 0.1% 1 1 1 1 1 1 1 1 1 1 1 1

Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 (DI1,2) 0 (NOT SEL) 3 (REQUEST) 0 (NOT SEL) 1 [REF1(Hz/rpm)] 0 (EXT1) 1 (KEYPAD)

User S

Group 04: FAULT HISTORY


LAST FAULT FAULT TIME FAULT TIME

Date dd.mm.yy / power-on time in days 1 day

SPEED AT FLT FREQ AT FLT VOLTAGE AT FLT CURRENT AT FLT TORQUE AT FLT STATUS AT FLT DI DI

1-3 AT FLT 4-6 AT FLT

PREVIOUS FAULT PREVIOUS FAULT

Group 10: START/STOP/DIR


EXT1 COMMANDS EXT2 COMMANDS DIRECTION

! ! ! !

JOGGING SEL

Group 11: REFERENCE SELECT


KEYPAD REF SEL EXT1/ EXT2 SEL REF1 SELECT REF1 MIN REF1 MAX

! !

0.1 Hz / 1 rpm 0.0 Hz / 0 rpm 0.1 Hz / 1 rpm 01: 50.0 Hz / 1500 rpm U1: 60.0 Hz / 1800 rpm 1 2 (AI2) 0.0% 100.0% 1 9 (DI3,4) U1: 360 rpm / 6.0 Hz ! !

REF2 SELECT REF2 MIN REF2 MAX

Group 12: CONSTANT SPEEDS


CONST SPEED SEL CONST SPEED

1 2 3 4

1 rpm / 0.1 Hz 01: 300 rpm / 5.0 Hz 1 rpm / 0.1 Hz 01: 600 rpm / 10.0 Hz U1: 720 rpm / 12.0 Hz 1 rpm / 0.1 Hz 01: 900 rpm / 15.0 Hz U1: 1080 rpm / 18.0 Hz 1 rpm / 0.1 Hz 01: 1200 rpm / 20.0 Hz U1: 1440 rpm / 24.0 Hz

CONST SPEED

CONST SPEED

CONST SPEED

Parameters

88

ACS550 Users Manual

Code 1206 1207 1208 1209 1301 1302 1303 1304 1305 1306 1401 1402 1403 1404 1405 1406 1407 1408 1409 1410 1411 1412 1413 1414 1415 1416 1417 1418 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510

Name
CONST SPEED

Range 5 6 7 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 1 = EXT/CS 1/2/3, 2 = CS1/2/3/4 0.0100.0% 0.0100.0% 0.010.0 s 0.0100.0% 0.0100.0% 0.010.0 s 1 2 3 047, 52 047, 52 047, 52 0.03600.0 s 0.03600.0 s 0.03600.0 s 0.03600.0 s 0.03600.0 s 0.03600.0 s 4 5 6 046, 52 046, 52 046, 52 0.03600.0 s 0.03600.0 s 0.03600.0 s 0.03600.0 s 0.03600.0 s 0.03600.0 s 99159 0.020.0 mA 0.020.0 mA 0.010.0 s 99159 0.020.0 mA

Resolution

Default U1: 1800 rpm / 30.0 Hz

User S

1 rpm / 0.1 Hz 01: 1500 rpm / 25.0 Hz 1 rpm / 0.1 Hz 01: 2400 rpm / 40.0 Hz U1: 2880 rpm / 48.0 Hz 1 rpm / 0.1 Hz 01: 3000 rpm / 50.0 Hz U1: 3600 rpm / 60.0 Hz 1 0.1% 0.1% 0.1 s 0.1% 0.1% 0.1 s 1 1 1 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 1 1 1 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 1 0.1 mA 0.1 mA 0.1 s 1 0.1 mA 2 (CS1/2/3/4) 0.0% 100.0% 0.1 s 0.0% 100.0% 0.1 s 1 (READY) 2 (RUN) 3 [FAULT(-1)] 0.0 s 0.0 s 0.0 s 0.0 s 0.0 s 0.0 s 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0.0 s 0.0 s 0.0 s 0.0 s 0.0 s 0.0 s 103 (tham s 0103 OUTPUT FREQ) Defined by par. 0103 Defined by par. 0103 0.0 mA 20.0 mA 0.1 s 104 (parameter 0104 CURRENT) Defined by par. 0104 Defined by par. 0104 0.0 mA !

CONST SPEED

CONST SPEED

TIMED MODE SEL

Group 13: ANALOG INPUTS


MINIMUM AI1 MAXIMUM AI1 FILTER AI1 MINIMUM AI2 MAXIMUM AI2 FILTER AI2

Group 14: RELAY OUTPUTS


RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT RO RO RO RO RO RO

1 ON DELAY 1 OFF DELAY 2 ON DELAY 2 OFF DELAY 3 ON DELAY 3 OFF DELAY

RELAY OUTPUT RELAY OUTPUT RELAY OUTPUT RO RO RO RO RO RO

4 ON DELAY 4 OFF DELAY 5 ON DELAY 5 OFF DELAY 6 ON DELAY 6 OFF DELAY

Group 15: ANALOG OUTPUTS


AO1 CONTENT SEL AO1 CONTENT MIN AO1 CONTENT MAX MINIMUM AO1 MAXIMUM AO1 FILTER AO1 AO2 CONTENT SEL AO2 CONTENT MIN AO2 CONTENT MAX MINIMUM AO2

Parameters

ACS550 Users Manual

89

Code 1511 1512 1601 1602 1603 1604 1605 1606 1607 1608 1609 1610 1611 2001 2002 2003 2005 2006 2007 2008 2013 2014 2015 2016 2017 2018 2101 2102 2103 2104 2105 2106 2107 2108 2109 2110 2112 2113

Name
MAXIMUM AO2 FILTER AO2

Range 0.020.0 mA 0.010.0 s -67 0 = LOCKED, 1 = OPEN, 2 = NOT SAVED 065535 -68 -66 -68 0 = DONE, 1 = SAVE 1 2 -67 -67 0 = NO, 1 = YES 0 = DEFAULT, 1 = FLASHDROP -3000030000 rpm 030000 rpm 0 1.8 I2hd 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE(TIME), 2 = ENABLE -500.0500.0 Hz 0.0500.0 Hz -67 -67 -600.00.0% -600.00.0% 0.0600.0% 0.0600.0% Vector control modes: 1, 2, 8 Scalar control mode: 15, 8 1 = COAST, 2 = RAMP 0.0010.00 s 0 = NOT SEL, 1 = DC HOLD, 2 = DC BRAKING 0360 rpm 0100% 0.0250.0 s 0 = OFF, 1 = ON -66 15300% 0.0 = NOT SEL, 0.160.0 s 0.0060.00 s

Resolution 0.1 mA 0.1 s 1 1 1 1 1 1 1 1 1 1 1 1 rpm 1 rpm 0.1 A 1 1 0.1 Hz 0.1 Hz 1 1 0.1% 0.1% 0.1% 0.1% 1 1 0.01 s 1 1 rpm 1% 0.1 s 1 1 1% 0.1 s 0.01 s

Default 20.0 mA 0.1 s 0 (NOT SEL) 1 (OPEN) 0 0 (KEYPAD) 0 (NOT SEL) 0 (NOT SEL) 0 (DONE) 0 (NOT SEL) 0 (NOT SEL) 0 (NO) 0 (DEFAULT) 0 rpm 01: 1500 rpm / U1: 1800 rpm 1.8 I2hd 1 (ENABLE) 1 [ENABLE( TIME)] 0.0 Hz 01: 50.0 Hz / U1: 60.0 Hz 0 (MIN TORQUE 1) 0 (MAX TORQUE 1) -300.0% -300.0% 300.0% 300.0% 8 (RAMP) 1 (COAST) 0.30 s 0 (NOT SEL) 5 rpm 30% 0.0 s 0 (OFF) 0 (NOT SEL) 100% 0.0 s (NOT SEL) 0.00 s

User S

Group 16: SYSTEM CONTROLS


RUN ENABLE PARAMETER LOCK PASS CODE FAULT RESET sEL USER PAR SET CHG LOCAL LOCK PARAM SAVE START ENABLE START ENABLE DISPLAY ALARMS PARAMETER VIEW

! !

Group 20: LIMITS


MINIMUM SPEED MAXIMUM SPEED

! ! !

MAX CURRENT OVERVOLT CTRL UNDERVOLT CTRL

MINIMUM FREQ MAXIMUM FREQ

! !

MIN TORQUE SEL MAX TORQUE SEL MIN TORQUE MIN TORQUE MAX TORQUE MAX TORQUE

1 2 1 2

Group 21: START/STOP


START FUNCTION

STOP FUNCTION DC MAGN TIME DC HOLD CTL

DC HOLD SPEED DC CURR REF DC BRAKE TIME START INHIBIT EMERG STOP SEL TORQ BOOST CURR ZERO SPEED DELAY START DELAY

Parameters

90

ACS550 Users Manual

Code 2201 2202 2203 2204 2205 2206 2207 2208 2209 2301 2302 2303 2304 2305 2401 2402 2501 2502 2503 2504 2505 2506 2507 2601 2602 2603 2604 2605 2606 2607 2608 2609 2619 2901 2902 2903 2904 2905 2906

Name
ACC/DEC

Range 1/2 SEL 1 1 1 2 2 2 0 -67 0.01800.0 s 0.01800.0 s 0.0 = LINEAR, 0.11000.0 s 0.01800.0 s 0.01800.0 s 0.0 = LINEAR, 0.11000.0 s 0.01800.0 s -67 0.00200.00 0.00600.00 s 010000 ms 0.00600.00 s 0 = OFF, 1 = ON 0.00120.00 s 0.00120.00 s 0 = OFF, 1 = ON 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 030000 rpm / 0.0500.0 Hz 0 = OFF, 1 = ON 0 = OFF, 1 = ON 0.0100.0 V 0100% 1 = LINEAR, 2 = SQUARED 1, 4, 8, 12 kHz 0 = OFF, 1 = ON 0200% 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 0.06553.5 kh, 0.0 disables 0.06553.5 kh 065535 Mrev, 0 disables 065535 Mrev 0.06553.5 kh, 0.0 disables 0.06553.5 kh

Resolution 1 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 0.1 s 1 0.01 0.01 s 1 ms 0.01 s 1 0.01 s 0.01 s 1

Default 5 (DI5) 5.0 s 5.0 s 0.0 s 60.0 s 60.0 s 0.0 s 1.0 s 0 (NOT SEL) 10.00 2.50 s 0 ms 0.00 s 0 (OFF) 0.00 s 0.00 s 0 (OFF)

User S

Group 22: ACCEL/DECEL

ACCELER TIME DECELER TIME RAMP SHAPE ACCELER TIME DECELER TIME RAMP SHAPE

EMERG DEC TIME RAMP INPUT

Group 23: SPEED CONTROL


PROP GAIN INTEGRATION TIME DERIVATION TIME ACC COMPENSATION AUTOTUNE RUN

Group 24: TORQUE CONTROL


TORQ RAMP UP TORQ RAMP DOWN

Group 25: CRITICAL SPEEDS


CRIT SPEED SEL CRIT SPEED CRIT SPEED CRIT SPEED CRIT SPEED CRIT SPEED CRIT SPEED

1 LO 1 HI 2 LO 2 HI 3 LO 3 HI

1 rpm / 0.1 Hz 0 rpm / 0.0 Hz 1 rpm / 0.1 Hz 0 rpm / 0.0 Hz 1 rpm / 0.1 Hz 0 rpm / 0.0 Hz 1 rpm / 0.1 Hz 0 rpm / 0.0 Hz 1 rpm / 0.1 Hz 0 rpm / 0.0 Hz 1 rpm / 0.1 Hz 0 rpm / 0.0 Hz 1 1 0.1 V 1% 1 1 1% 1 1 0.1 kh 0.1 kh 1 Mrev 1 Mrev 0.1 kh 0.1 kh 0 (OFF) 0 (OFF) Size dependent 80% 1 (LINEAR) 4 kHz 1 (ON) 0 0 (DISABLE) 0 (DISABLE) 0.0 kh 0.0 kh 0 Mrev 0 Mrev 0.0 kh 0.0 kh

Group 26: MOTOR CONTROL


FLUX OPT ENABLE FLUX BRAKING IR COMP VOLT IR COMP FREQ U/F RATIO SWITCHING FREQ SWITCH FREQ CTRL SLIP COMP RATIO NOISE SMOOTHING DC STABILIZER

Group 29: MAINTENANCE TRIG


COOLING FAN TRIG COOLING FAN ACT REVOLUTION TRIG REVOLUTION ACT RUN TIME TRIG RUN TIME ACT

Parameters

ACS550 Users Manual

91

Code 2907 2908 3001 3002 3003 3004 3005 3006 3007 3008 3009 3010 3011 3012 3017 3018 3019 3021 3022 3023 3024 3101 3102 3103 3104 3105 3106 3107 3108 3201 3202 3203 3204 3205 3206 3207 3208 3209

Name
USER USER

Range MWh TRIG MWh ACT 0.06553.5 MWh, 0.0 disables 0.06553.5 MWh 03 13 1 2 -66 -66 0 = NOT SEL, 1 = FAULT, 2 = ALARM 2569999 s 50150% 25150% 1250 Hz 0 = NOT SEL, 1 = FAULT, 2 = ALARM 0.550 Hz 10400 s 0 = DISABLE, 1 = ENABLE 0 = NOT SEL, 1 = FAULT, 2 = CONST SP 7, 1 3 = LAST SPEED 060.0 s 0100% 0100% 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 05 1.0600.0 s 0.0120.0 s 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 100 = NOT SELECTED, 101159 100 = NOT SELECTED, 101159 100 = NOT SELECTED, 101159 -

Resolution 0.1 MWh 0.1 MWh 1 1 1 1 1 1 1 1 1 1 0.1 Hz 1s 1

Default 0.0 MWh 0.0 MWh 0 (NOT SEL) 1 (FAULT) 0 (NOT SEL) 0 (NOT SEL) 1 (FAULT) 500 s 100% 70% 35 Hz 0 (NOT SEL) 20 Hz 20 s 1 (ENABLE) 0 (NOT SEL)

User S

Group 30: FAULT FUNCTIONS


AI<MIN FUNCTION PANEL COMM ERR EXTERNAL FAULT EXTERNAL FAULT MOT THERM PROT MOT THERM TIME MOT LOAD CURVE ZERO SPEED LOAD BREAK POINT FREQ STALL FUNCTION STALL FREQUENCY STALL TIME EARTH FAULT COMM FAULT FUNC

COMM FAULT TIME AI1 FAULT LIMIT AI2 FAULT LIMIT WIRING FAULT CB TEMP FAULT

0.1 s 0.1% 0.1% 1 1 1 0.1 s 0.1 s 1 1 1 1 1 1 1 1 -

3.0 s 0% 0% 1 (ENABLE) 1 (ENABLE) 0 30 s 0s 0 (DISABLE) 0 (DISABLE) 0 (DISABLE) 0 (DISABLE) 0 (DISABLE) 103 (parameter 0103 OUTPUT FREQ) 0 0 104 (parameter 0104 CURRENT) 0 0 105 (parameter 0105 TORQUE) 0 0 !

Group 31: AUTOMATIC RESET


NUMBER OF TRIALS TRIAL TIME DELAY TIME AR OVERCURRENT AR OVERVOLTAGE AR UNDERVOLTAGE AR AI<MIN AR EXTERNAL FLT

Group 32: SUPERVISION


SUPERV

1 PARAM 1 LIM LO 1 LIM HI 2 PARAM 2 LIM LO 2 LIM HI 3 PARAM 3 LIM LO 3 LIM HI

SUPERV SUPERV SUPERV

SUPERV SUPERV SUPERV

SUPERV SUPERV

Parameters

92

ACS550 Users Manual

Code 3301 3302 3303 3304 3305 3401 3402 3403 3404 3405 3406 3407 3408 3409 3410 3411 3412 3413 3414 3415 3416 3417 3418 3419 3420 3421 3501 3502 3503

Name

Range 0000FFFF hex 0000FFFF hex yy.ww 0000FFFF hex 100 = NOT SELECTED, 101159 09 0127 100 = NOT SELECTED, 101159 09 0127 100 = NOT SELECTED, 101159 09 0127 06 18 Par. 3501 = 13: -10200 C Par. 3501 = 4: 05000 ohm Par. 3501 = 56: 01 Par. 3501 = 13: -10200 C Par. 3501 = 4: 05000 ohm Par. 3501 = 56: 01 -67 00:00:0023:59:58 00:00:0023:59:58 17 17 2 00:00:0023:59:58

Resolution 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Default Firmware version 0 0 Par. table version 103 (parameter 0103 OUTPUT FREQ) 9 (DIRECT) 104 (parameter 0104 CURRENT) 9 (DIRECT) 105 (parameter 0105 TORQUE) 9 (DIRECT) 0 (NONE) 1 (AI1) 110 C / 1500 ohm / 0

User S

Group 33: INFORMATION


FIRMWARE LOADING PACKAGE TEST DATE DRIVE RATING PARAMETER TABLE

Group 34: PANEL DISPLAY


SIGNAL1 PARAM SIGNAL1 MIN SIGNAL1 MAX OUTPUT1 DSP FORM OUTPUT1 UNIT OUTPUT1 MIN OUTPUT1 MAX SIGNAL2 PARAM SIGNAL2 MIN SIGNAL2 MAX OUTPUT2 DSP FORM OUTPUT2 UNIT OUTPUT2 MIN OUTPUT2 MAX SIGNAL3 PARAM SIGNAL3 MIN SIGNAL3 MAX OUTPUT3 DSP FORM OUTPUT3 UNIT OUTPUT3 MIN OUTPUT3 MAX

Group 35: MOTOR TEMP MEAS


SENSOR TYPE INPUT SELECTION ALARM LIMIT

3504

FAULT LIMIT

130 C / 4000 ohm / 0

Group 36: TIMED FUNCTIONS 3601 3602 3603 3604 3605 3606
TIMERS ENABLE START TIME STOP TIME START DAY STOP DAY START TIME

1 2s 2s 1 1 2s

0 (NOT SEL) 00:00:00 00:00:00 1 (MONDAY) 1 (MONDAY) 00:00:00

1 1 1 1

Parameters

ACS550 Users Manual

93

Code 3607 3608 3609 3610 3611 3612 3613 3614 3615 3616 3617 3622 3623 3626 3629

Name
STOP TIME START DAY STOP DAY START TIME STOP TIME START DAY STOP DAY START TIME STOP TIME START DAY STOP DAY

Range 2 2 2 3 3 3 3 4 4 4 4 00:00:0023:59:58 17 17 00:00:0023:59:58 00:00:0023:59:58 17 17 00:00:0023:59:58 00:00:0023:59:58 17 17 -66 00:00:0023:59:58 14 SRC 031

Resolution 2s 1 1 2s 2s 1 1 2s 2s 1 1 1 2s 1

Default 00:00:00 1 (MONDAY) 1 (MONDAY) 00:00:00 00:00:00 1 (MONDAY) 1 (MONDAY) 00:00:00 00:00:00 1 (MONDAY) 1 (MONDAY) 0 (NOT SEL) 00:00:00 0 (NOT SEL)

User S

BOOSTER SEL BOOSTER TIME TIMED FUNC

Group 37: USER LOAD CURVE 3701 3702 3703 3704 3705 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715 3716 3717 3718 4001 4002 4003 4004 4005 4006 4007 4008
USER LOAD C MODE USER LOAD C FUNC USER LOAD C TIME LOAD FREQ

03 1 = FAULT, 2 = ALARM 10400 s 0500 Hz

1 1 1s 1 Hz 1% 1% 1 Hz 1% 1% 1 Hz 1% 1% 1 Hz 1% 1% 1 Hz 1% 1% 0.1 0.1 s 0.1 s 0.1 s 1 1 1

0 (NOT SEL) 1 (FAULT) 20 s 5 Hz 10% 300% 25 Hz 15% 300% 43 Hz 25% 300% 50 Hz 30% 300% 500 Hz 30% 300% 1.0 60.0 s 0.0 s 1.0 s 0 (NO) 4 (%) 1 0.0%

1 1 1 2 2 3 3 4 4 5 5

LOAD TORQ LOW LOAD TORQ HIGH LOAD FREQ

0600% 0600% 0500 Hz 0600% 0600% 0500 Hz 0600% 0600% 0500 Hz 0600% 0600% 0500 Hz 0600% 0600% 0.1100.0 0.0 = NOT SEL, 0.13600.0 s 0.010.0 s 0.010.0 s 0 = NO, 1 = YES 0127 04 Unit and scale defined by par. 4006 and 4007

LOAD TORQ LOW LOAD TORQ HIGH LOAD FREQ

LOAD TORQ LOW LOAD TORQ HIGH LOAD FREQ

LOAD TORQ LOW LOAD TORQ HIGH LOAD FREQ

LOAD TORQ LOW LOAD TORQ HIGH

Group 40: PROCESS PID SET 1


GAIN INTEGRATION TIME DERIVATION TIME PID DERIV FILTER ERROR VALUE INV UNITS UNIT SCALE

0% VALUE

Parameters

94

ACS550 Users Manual

Code 4009 4010 4011 4012 4013 4014 4015 4016 4017 4018 4019 4020 4021 4022 4023 4024 4025 4026 4027 4101 4102 4103 4104 4105 4106 4107 4108 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 4120 4121

Name 100% VALUE


SET POINT SEL INTERNAL SETPNT

Range Unit and scale defined by par. 4006 and 4007 02, 817, 1920 Unit and scale defined by par. 4006 and 4007 -500.0500.0% -500.0500.0% 113 0.000 = NOT SEL, -32.76832.767 17 17 -10001000% -10001000% -10001000% -10001000% -67 030000 rpm / 0.0500.0 Hz 0.03600.0 s Unit and scale defined by par. 4006 and 4007 0.0060.00 s -614 0.1100.0 0.0 = NOT SEL, 0.13600.0 s 0.010.0 s 0.010.0 s 0 = NO, 1 = YES 0127 04 Unit and scale defined by par. 4106 and 4107 Unit and scale defined by par. 4106 and 4107 02, 817, 1920 Unit and scale defined by par. 4106 and 4107 -500.0500.0% -500.0500.0% 113 0.000 = NOT SEL, -32.76832.767 17 17 -10001000% -10001000% -10001000% -10001000%

Resolution

Default 100.0%

User S

1 (AI1) 40.0%

SETPOINT MIN SETPOINT MAX FBK SEL FBK MULTIPLIER ACT1 INPUT ACT2 INPUT ACT1 MINIMUM ACT1 MAXIMUM ACT2 MINIMUM ACT2 MAXIMUM SLEEP SELECTION PID SLEEP LEVEL PID SLEEP DELAY WAKE-UP DEV WAKE-UP DELAY PID

0.1% 0.1% 1 0.001 1 1 1% 1% 1% 1% 1 0.1 s

0.0% 100.0% 1 (ACT1) 0.000 (NOT SEL) 2 (AI2) 2 (AI2) 0% 100% 0% 100% 0 (NOT SEL) 60.0 s 0.0% ! !

1 rpm / 0.1 Hz 0 rpm / 0.0 Hz

0.01 s 1 0.1 0.1 s 0.1 s 0.1 s 1 1 1

0.50 s 0 (SET 1) 1.0 60.0 s 0.0 s 1.0 s 0 (NO) 4 (%) 1 0.0% 100.0%

1 PARAM sET

Group 41: PROCESS PID SET 2


GAIN INTEGRATION TIME DERIVATION TIME PID DERIV FILTER ERROR VALUE INV UNITS UNIT SCALE

0% VALUE 100% VALUE


SET POINT SEL INTERNAL SETPNT

1 (AI1) 40.0%

SETPOINT MIN SETPOINT MAX FBK SEL FBK MULTIPLIER ACT1 INPUT ACT2 INPUT ACT1 MINIMUM ACT1 MAXIMUM ACT2 MINIMUM ACT2 MAXIMUM

0.1% 0.1% 1 0.001 1 1 1% 1% 1% 1%

0.0% 100.0% 1 (ACT1) 0.000 (NOT SEL) 2 (AI2) 2 (AI2) 0% 100% 0% 100% ! !

Parameters

ACS550 Users Manual

95

Code 4122 4123 4124 4125 4126 4201 4202 4203 4204 4205 4206 4207 4208 4209 4210 4211 4212 4213 4214 4215 4216 4217 4218 4219 4220 4221 4228 4229 4230 4231 4232 5001 5002 5003 5010 5011 5101

Name
SLEEP SELECTION PID SLEEP LEVEL PID SLEEP DELAY WAKE-UP DEV WAKE-UP DELAY

Range -67 030000 rpm / 0.0500.0 Hz 0.03600.0 s Unit and scale defined by par. 4106 and 4107 0.0060.00 s 0.1100.0 0.0 = NOT SEL, 0.13600.0 s 0.010.0 s 0.010.0 s 0 = NO, 1 = YES 0127 04 Unit and scale defined by par. 4206 and 4207 Unit and scale defined by par. 4206 and 4207 02, 817, 1920 Unit and scale defined by par. 4206 and 4207 -500.0500.0% -500.0500.0% 113 0.000 = NOT SEL, -32.76832.767 17 17 -10001000% -10001000% -10001000% -10001000% -612 0.0100.0% 0 = NOT SEL, 1 = PROPORTIONAL, 3 = DIRECT -100.0100.0% 1 = PID2REF, 2 = PID2OUTPUT 5016384 0 = DISABLE, 1 = ENABLE 1 = FAULT, 2 = ALARM 0 = DISABLE, 1 = ENABLE 0 = DISABLE, 1 = ENABLE 065535

Resolution 1 0.1 s

Default 0 (NOT SEL) 60.0 s 0.0%

User S

1 rpm / 0.1 Hz 0 rpm / 0.0 Hz

0.01 s 0.1 0.1 s 0.1 s 0.1 s 1 1 1

0.50 s 1.0 60 s 0.0 s 1.0 s 0 (NO) 4 (%) 1 0.0% 100.0%

Group 42: EXT / TRIM PID


GAIN INTEGRATION TIME DERIVATION TIME PID DERIV FILTER ERROR VALUE INV UNITS UNIT SCALE

0% VALUE 100% VALUE


SET POINT SEL INTERNAL SETPNT

1 (AI1) 40.0%

SETPOINT MIN SETPOINT MAX FBK SEL FBK MULTIPLIER ACT1 INPUT ACT2 INPUT ACT1 MINIMUM ACT1 MAXIMUM ACT2 MINIMUM ACT2 MAXIMUM ACTIVATE OFFSET TRIM MODE

0.1% 0.1% 1 0.001 1 1 1% 1% 1% 1% 1 0.1% 1 0.1% 1 1 1 1 1 1 1

0.0% 100.0% 1 (ACT1) 0.000 (NOT SEL) 2 (AI2) 2 (AI2) 0% 100% 0% 100% 0 (NOT SEL) 0.0% 0 (NOT SEL) 0.0% 1 ( PID2REF) 1024 0 (DISABLE) 1 (FAULT) 0 (DISABLE) 0 (DISABLE) 0 (NOT DEFINED) 0 ! ! ! ! ! !

TRIM SCALE CORRECTION SRC

Group 50: ENCODER


PULSE NR ENCODER ENABLE ENCODER FAULT Z PLS ENABLE POSITION RESET

Group 51: EXT COMM MODULE


FBA TYPE

5102 FB PAR 226 5126

Parameters

96

ACS550 Users Manual

Code 5127 5128 5129 5130 5131 5132 5133 5201 5202 5203 5204 5205 5206 5207 5208 5301 5302 5303 5304 5305 5306 5307 5308 5309 5310 5311 5312 5313 5314 5315 5316 5317 5318 5319 5320 8103 8104 8105

Name
FBA PAR REFRESH FILE CPI FW REV FILE CONFIG ID FILE CONFIG REV FBA STATUS FBA CPI FW REV FBA APPL FW REV

Range 0 = DONE, 1 = REFRESH 00xFFFF (hex) 00xFFFF (hex) 00xFFFF (hex) 06 00xFFFF (hex) 00xFFFF (hex) 1247 9.6, 19.2, 38.4, 57.6, 115.2 kbits/s 0 = 8 NONE 1, 1 = 8 NONE 2, 2 = 8 EVEN 1, 3 = 8 ODD 1 065535 065535 065535 065535 065535 00xFFFF 065535 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 76.8 kbits/s 0 = 8 NONE 1, 1 = 8 NONE 2, 2 = 8 EVEN 1, 3 = 8 ODD 1 0 = ABB DRV LIM, 1 = DCU PROFILE, 2 = ABB DRV FULL 065535 065535 065535 07 065535 065535 065535 065535 065535 065535 065535 065535 065535 00xFFFF (hex) 00xFFFF (hex) 1 2 3 0.0100.0% 0.0100.0% 0.0100.0%

Resolution 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Default 0 (DONE) 0 0 0 0 (IDLE) 0 0 1 9.6 kbits/s 0 (8 NONE 1) 0 1 9.6 kbits/s 0 (8 NONE 1)

User S !

Group 52: PANEL COMM


STATION ID BAUD RATE PARITY

OK MESSAGES PARITY ERRORS FRAME ERRORS BUFFER OVERRUNS CRC ERRORS

Group 53: EFB PROTOCOL


EFB PROTOCOL ID EFB STATION ID EFB BAUD RATE

EFB PARITY

EFB CTRL PROFILE

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0.1% 0.1% 0.1%

0 (ABB DRV LIM) 0 0 0 0 (IDLE) 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0 (NOT SEL) 0 0 0 0.0% 0.0% 0.0%

EFB OK MESSAGES EFB CRC ERRORS EFB UART ERRORS EFB STATUS EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR EFB PAR

10 11 12 13 14 15 16 17 18 19 20

Group 81: PFC CONTROL


REFERENCE STEP REFERENCE STEP REFERENCE STEP

Parameters

ACS550 Users Manual

97

Code 8109 8110 8111 8112 8113 8114 8115 8116 8117 8118 8119 8120 8121 8122 8123 8124 8125 8126 8127 8128 9802

Name
START FREQ

Range 1 2 3 0.0500.0 Hz 0.0500.0 Hz 0.0500.0 Hz 0.0500.0 Hz 0.0500.0 Hz 0.0500.0 Hz 0.03600.0 s 0.03600.0 s 04 -0.1 = TEST MODE, 0.0 = NOT SEL, 0.1336 h 0.0100.0% 06 0 = NO, 1 = YES 0.0010.00 s 0 = NOT SEL, 1 = ACTIVE 0.0 = NOT SEL, 0.11800.0 s 0.0 = NOT SEL, 0.11800.0 s 04 17 1 = EVEN RUNTIME, 2 = RELAY ORDER 0 = NOT SEL, 1 = STD MODBUS, 4 = EXT FBA

Resolution 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 Hz 0.1 s 0.1 s 1 0.1 h 0.1% 1 1 0.01 s 1 0.1 s 0.1 s 1 1 1 1

Default 01: 50.0 Hz / U1: 0.0 Hz 01: 50.0 Hz / U1: 0.0 Hz 01: 50.0 Hz / U1: 0.0 Hz 01: 25.0 Hz / U1: 30.0 Hz 01: 25.0 Hz / U1: 30.0 Hz 01: 25.0 Hz / U1: 30.0 Hz 5.0 s 3.0 s 1 0.0 h ( NOT SEL) 50% 4 (DI4) 0 (NO) 0.50 s 0 (NOT SEL) 0.0 s (NOT SEL) 0.0 s (NOT SEL) 0 (NOT SEL) 2 1 (EVEN RUNTIME) 0 (NOT SEL)

User S

START FREQ

START FREQ

LOW FREQ

1 2 3

LOW FREQ

LOW FREQ

AUX MOT START D AUX MOT STOP D NR OF AUX MOT AUTOCHNG INTERV

! !

AUTOCHNG LEVEL INTERLOCKS REG BYPASS CTRL PFC START DELAY PFC ENABLE ACC IN AUX STOP DEC IN AUX START TMED AUTOCHNG MOTORS AUX START ORDER

! ! !

Group 98: OPTIONS


COMM PROT SEL

Parameters

98

ACS550 Users Manual

B sung cc m t tham s
Phn ny m t tn hiu thc t v cc thng s cho ACS550. Nhm 99: START-UP DATA Nhm ny xc nh d liu khi ng c bit yu cu : Thit lp bin tn . Nhp thng tin ca ng c.
M s 9901 m t LANGUAGE

Chn hin th ngn ng. c hai Assistant Control Panels, mi b h tr mt ngn ng khc nhau . (Panel ACS-CP-L h tr cc ngn ng 0, 2, 1115 s c tch hp vo ACS-CP-A.)
Assistant Control Panel ACS-CP-A: 0 = ENGLISH 1 = ENGLISH (AM) 5 = PORTUGUES 6 = NEDERLANDS 10 = SVENSKA 11 = RUSSKI 15 = MAGYAR Assistant Control Panel ACS-CP-D (Asia): 0 = ENGLISH 1 = CHINESE 9902 APPLIC MACRO 2 = DEUTSCH 7 = FRANAIS 12 = POLSKI 3 = ITALIANO 8 = DANSK 13 = TRKE 4 = ESPAOL 9 = SUOMI 14 = CZECH

2 = KOREAN

3 = JAPANESE

La chn ng dng macro. ng dng macro t ng sa i cu hnh thng s ACS550 cho ng dng c th .
1 = ABB STANDARD 6 = PID CONTROL 0 = USER S1 LOAD 2 = 3-WIRE 7 = PFC CONTROL -1 = USER S1 SAVE 3 = ALTERNATE 8 = TORQUE CTRL -2 = USER S2 LOAD 4 = MOTOR POT 5 = HAND/AUTO 31 = LOAD FD SET -3 = USER S2 SAVE

tham s 1611 PARAMETER VIEW. FlashDrop l mt thit b ty chn cho vic sao chp nhanh chng khng cn ngun bin tn. FlashDrop cho php d dng sa i ring ca danh sch tham s, e.g. chn thng s n. bit thm thng tin, xem MFDT-01FlashDrop Users Manual [3AFE68591074 (English)]. -1 = USER S1 SAVE, -3 = USER S2 SAVE c th lu hai thng s ngi dng khc nhau t vo b nh vnh vin bin tn cho s dng sau ny. Mi b c thit lp thng s, bao gm nhm 99: START-UP DATA, v kt qu ca vic chy nhn dng ng c. 0 = USER S1 LOAD, -2 = USER S2 LOAD vi nhng b tham s s dng c th c a tr li s dng
9904 . MOTOR CTRL MODE

31 = LOAD FD SET FlashDrop gi tr tham s c xc nh bi tp tin FlashDrop . Thng s xem c chn bi

Chn ch kim sot ng c. 1 = VECTOR : SPEED Cm bin ch iu khin vector. Tham chiu 1 = tc tham chiu trong vng/ pht. Tham chiu 2 = tc tham chiu trong phn trm. 100% tc tuyt i, ln nht, bng vi gi tr ca

tham s 2002MAXIMUM SPEED (hoc 2001 MINIMUM SPEED nu gi tr tuyt i ca tc nh nht ln hn gi tr tc ln nht ).

2 = VECTOR : TORQ. Tham chiu 1 = tc tham chiu trong vng/ pht . Tham chiu 2 = momen xon tham chiu trong phn trm .(100% =momen xon danh nh ) 3 = SCALAR : FREQ Ch iu khin v hng. Tham chiu 1 = tn s tham chiu trong Hz. Tham chiu 2 = tn s tham chiu trong phn trm. 100% l tn s tuyt i ln nht, bng vi gi tr ca

tham s 2008 (hoc 2007 MINIMUM FREQUENCY nu gi tr tuyt i ca tc nh nht ln hn gi tr tc ln nht).

9905

MOTOR NOM VOLT

Xc nh in p danh nh ng c. phi bng vi gi tr trn nhn my. ACS550 khng th cung cp cho ng c vi in p ln hn in p ngun u vo (li in).

Parameters

ACS550 Users Manual

99

Code Description 9906 MOTOR NOM CURR

Xc nh dng in danh nh ng c. Phi ng bng gi tr ghi trn nhn my. phm vi cho php: 0.22.0 I2hd (ni I2hd l dng in bin tn).
9907 MOTOR NOM FREQ

Xc nh tn s danh nh ng c bin : 10500 Hz (thng l 50 hoc 60 Hz) thit lp tn s m ti u ra in p bng vi MOTOR NOM VOLT. phm vi im suy yu = Nom Freq cung cp Volt / Mot in p danh nh.
9908 MOTOR NOM SPEED

Xc nh tc danh nh ng c. Phi ng bng gi tr ghi trn nhn my.


9909 MOTOR NOM POWER

Xc nh cng sut danh nh ng c. Phi ng bng gi tr ghi trn nhn my.


9910 ID RUN

Tham s iu khin ny l mt qu trnh hiu chun c gi l Motor ID Run trong qu trnh ny, bin tn vn hnh ng c v to ra mt php o xc nh c tnh ng c v to ra mt model s dng tnh ton ni b
. ID Run c bit hiu qu khi : ch kim sot vector c s dng [tham s 9904 = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ)], v/hoc im hot ng l tc gn bng khng, v/hoc hot ng i hi mt lot momen xon trn momen xon danh nh ng c, trn mt phm vi tc rng, v khng c bt k phn hi tc (i.e. tc l khng c b m ha xung). 0 = OFF/IDMAGN Qu trnh Motor ID Run l khng chy. Xc nh t tnh c thc hin, ty, thuc vo ci

t tham s 9904 v 2101. trong xc nh t tnh, model ng c c tnh khi ng u ln bi t tnh ca ng c cho 10 n 15 s ti tc 0 (ng c khng xoay). model ny lun lun c tnh lc khi ng sau khi thay i thng s ca ng c.. Tham s 9904 = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ): xc nh t tnh c thc hin. Tham s 9904 = 3 (SCALAR:FREQ) v tham s 2101 = 3 (SCALAR FLYST) hoc 5 (FLY + BOOST): xc nh t tnh c thc hin. Tham s 9904 = 3 (SCALAR:FREQ) v tham s 2101 c gi tr khc ngoi 3 (SCALAR FLYST) hoc 5 (FLY + BOOST): xc nh t tnh khng c thc hin Ch : ng c khng c ghp i t cc thit b iu khin. Ch : Kim tra hng quay ca ng c trc khi khi ng ID Run.
Cnh bo! ng c s chy ln ti khong 5080% ca tc danh nh trong khi ID Run. ng c s xoay theo hng thun . m bo rng n l an ton chy ng c trc khi thc hin ID Run! Xem thm phn How to perform the ID Run trn trang 39.

1 = ON cho php ng c ID Run, trong thi gian ng c quay, theo lnh khi ng tip theo. Sau khi chy hon thnh, gi tr ny s thay i n khng .

Parameters

100

ACS550 Users Manual

nhm 01: OPERATING DATA Nhm ny cha d liu iu hnh bin tn, bao gm c cc tn hiu thc t. bin tn thit lp gi tr cho tn hiu thc t, da trn cc php o hoc tnh ton. Bn khng th thit lp cc gi tr ny .
Code Description 0101 SPEED & DIR

Tnh tc ng c trong vng/pht. Gi tr tuyt i ca 0101 SPEED & DIR l ging nh gi tr ca


0102 SPEED. gi tr ca 0101 SPEED & DIR l dng nu ng c quay theo chiu thun. gi tr ca 0101 SPEED & DIR l m nu ng c quay theo chiu nghch. 0102 SPEED

Tnh tc ng c trong vng/pht. (tham s 0102 hoc 0103 c hin th bi mc nh trong bng iu khin ch
u ra.) 0103 OUTPUT FREQ Tn s (Hz) p dng cho ng c. (tham s 0102 hoc 0103 c hin th bi mc nh trong bng iu khin ch u ra .) 0104 0105 CURRENT Dng in ng c, c o bng ACS550. (hin th bi mc nh trong bng iu khin ch u ra.) TORQUE u ra momen xon. tnh gi tr momen xon trn trc ng c trong % ca momen xon danh nh ng c. (hin th bi mc nh trong bng iu khin ch u ra.) 0106 0107 0109 0110 0111 0112 0113 POWER

o cng sut ng c n v kW .
DC BUS VOLTAGE DC bus in p trong V DC, nh c o bi ACS550. OUTPUT VOLTAGE in p p dng cho bin tn. DRIVE TEMP Nhit ngun transistor ca bin tn trong C. EXTERNAL REF 1 Tham chiu ngoi, REF1, trong rpm hoc Hz n v thp phn bi tham s 9904. EXTERNAL REF 2 Tham chiu ngoi, REF2, trong %. CTRL LOCATION Hot ng v tr kim sot. Cc la chn thay th: 0 = LOCAL 1 = EXT1 2 = EXT2 0114 RUN TIME (R) Bin tn tch ly thi gian chy trong gi (h). c th reset bi nhn UP v DOWN phm ng thi khi bng iu khin ch thng s. 0115 KWH COUNTER (R) Cng sut tiu th ca bin tn c tch ly trong kilowatt gi. c th reset bng cch nhn UP v DOWN ng thi khi bng iu khin ch thng s. 0116 APPL BLK OUTPUT ng dng chn u ra tn hiu. gi tr t mt trong hai : kim sot PFC, nu kim sot PFC l kch hot, hoc thng s 0112 EXTERNAL REF 2.

Parameters

ACS550 Users Manual

101

Code Description 0118 DI 1-3 STATUS Tnh trng ca ba u vo k thut s . tnh trng hin th nh mt s nh phn . 1 cho thy rng u vo l hot ng . 0 cho thy rng u vo l khng hot ng . 0119 DI 4-6 STATUS Tnh trng ca ba u vo k thut s . xem thng s 0118 DI 1-3 STATUS. 0120 0121 0122 AI 1 Gi tr tng i ca u vo k thut s 1 trong %. AI 2 Gi tr tng i ca u vo k thut s 2 trong %. RO 1-3 STATUS Tnh trng ca ba u u ra relay . 1 ch ra rng relay c kch hot. 0 ch ra rng relay khng c kch hot. RO 4-6 STATUS Tnh trng ca ba u u ra relay . xem thng s 0122. 0124 AO 1 Gi tr u ra tng t 1 trong milliampe . 0125 AO 2 Gi tr u ra tng t 2 trong milliampe . 0126 0127 0128 PID 1 OUTPUT B iu khin PID 1 u ra gi tr trong %. PID 2 OUTPUT B iu khin PID 2 u ra gi tr trong %. PID 1 SETPNT im t tn hiu b iu khin PID 1. n v v phm vi xc nh bi cc thng s PID. 0129 PID 2 SETPNT im t tn hiu b iu khin PID 2. n v v phm vi xc nh bi cc thng s PID . 0130 PID 1 FBK Tn hiu phn hi b iu khin PID 1 . n v v phm vi xc nh bi cc thng s PID. 0131 PID 2 FBK Tn hiu phn hi b iu khin PID2. n v v phm vi xc nh bi cc thng s PID. 0132 PID 1 DEVIATION S khc nhau gia tham chiu b iu khin PID 1 v gi tr thc t. n v v phm vi xc nh bi cc thng s PID. 0133 PID 2 DEVIATION S khc nhau gia tham chiu b iu khin PID 2 v gi tr thc t. n v v phm vi xc nh bi cc thng s PID. 0134 COMM RO WORD V tr d liu c lp c th c ni tip bng vn bn ca lin kt. c s dng cho kim sot u ra relay. xem tham s 1401. 0135 COMM VALUE 1 V tr d liu c lp c th c ni tip bng vn bn ca lin kt .
RELAY DI

DI

DI

0123

1 STATUS

RELAY 2 STATUS RELAY 3 STATUS

Parameters

102

ACS550 Users Manual

Code Description 0136 0137 COMM VALUE 2 V tr d liu c lp c th c ni tip bng vn bn ca lin kt. PROCESS VAR 1

Bin iu chnh 1 c xc nh bi tham s trong nhm 34: PANEL DISPLAY.


0138 PROCESS VAR 2

Bin iu chnh 2 c xc nh bi tham s trong nhm 34: PANEL DISPLAY.


0139 PROCESS VAR 3

Bin iu chnh 3 c xc nh bi tham s trong nhm 34: PANEL DISPLAY.


0140 RUN TIME Tnh dn thi gian chy ca bin tn trong hng ngn gi (kh). khng th t li. 0141 MWH COUNTER Tnh dn in nng tiu th bin tn trong megawatt gi . khng th t li. 0142 REVOLUTION CNTR Tnh dn s vng quay ca ng c trong hng triu vng quay. c th c t li bng cch nhn phm UP v DOWN ng thi khi bng iu khin ch thng s. 0143 DRIVE ON TIME HI Tnh dn thi gian bt ngun trong ngy . khng th t li. 0144 DRIVE ON TIME LO Tnh dn thi gian bt ngun trong 2 giy ticks (30 ticks = 60 giy). th hin trong nh dng hh.mm.ss. khng th t li. 0145 MOTOR TEMP Nhit ng c trong C / PTC in tr trong ohms. ch p dng nu cm bin nhit ng c c thit lp. xem thng s 3501. 0146 MECH ANGLE Xc nh v tr gc ca trc ng c khong 0.01 (32,768 n v vi 360). V tr ny xc nh l 0 ti bt ngun. trong thi gian hot ng v tr khng th t li bi : mt u vo xung Z-, nu thng s 5010 Z PLS ENABLE = 1 (ENABLE) thng s 5011 POSITION RESET, nu thng s 5010 Z PLS ENABLE = 2 (DISABLE) bt k thay i ca thng s 5002 ENCODER ENABLE. 0147 MECH REVS Mt s nguyn rng m y vng quay ca trc ng c. Gi tr : tng khi tham s 0146 MECH ANGLE thay i t 32767 n 0 gim khi tham s 0146 MECH ANGLE thay i t 0 n 32767. 0148 Z PLS DETECTED Xung d Encoder khng. Khi mt xung Z- xc nh v tr khng, trc phi i qua v tr 0 kch hot xung Z-pulse. Cho n lc , v tr khng bit (bin tn s dng v tr trc ti m ngun nh s 0 ). Tn hiu tham s ny nh tham s 0146 MECH ANGLE l hp l. tham s khi ng l 0 = NOT DETECTED trn bt ngun v thay i n 1 = DETECTED ch khi no : tham s 5010 Z PLS ENABLE = 1 (ENABLE) v mt b m ha xung Z- c pht hin. 0150 CB TEMP Nhit ca board kim sot ng c trong C. CH : mt s bin tn c kim sot board (OMIO) m khng h tr tnh nng ny. Cc bin tn lun lun hin th gi tr khng i ca 25.0 C.

Parameters

ACS550 Users Manual

103

Code Description 0151 INPUT KWH (R) Tnh cng sut tiu th thc t trong kWh. 0152 0158 0159 INPUT MWH Tnh nng lng tiu th trong MWh. PID COMM VALUE 1 D liu nhn c t fieldbus cho iu khin PID (PID1 v PID2). PID COMM VALUE 2 D liu nhn c t fieldbus cho iu khin PID (PID1 v PID2).

Parameters

104

ACS550 Users Manual

nhm 03: FB gi tr thc t Nhm ny theo di thng tin lin lc fieldbus.


M 0301 m t FB CMD WORD 1 ch c bng sao Fieldbus lnh Word 1. lnh fieldbus l phng php iu khin bin tn t b iu khin fieldbus. Lnh thnh phn ca hai Command Words. Bit- m hng dn trong lnh chuyn i Words bin tn gia cc trng thi . kim sot bin tn, bng cch s dng Command Words, mt v tr bn ngoi (EXT1 hoc EXT2) phi c hot ng v Thit lp n COMM. (xem thng s 1001 V 1002.) bng iu khin hin th t trong hex .cho v d, tt c cc s 0 v mt s 1 trong Bit 0 hin th nh 0001. tt c cc s 0 v mt s 1 trong Bit 15 hin th nh 8000. 0302 FB CMD WORD 2 Ch c bng sao Fieldbus Command Word 2. xem thng s 0301. Bit # 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0303 FB STS WORD 1 Ch c bng sao ca Status Word 1. bin tn s gi thng tin trng thi iu khin fieldbus. Trng thi ny bao gm hai Status Words. kim sot bng iu khin hin th hex. V D, tt c cc s 0 v mt s 1 trong Bit 0 hin th nh 0001. tt c khng v 1 trong Bit 15 hin th nh 8000. 0304 FB STS WORD 2 Ch c bng sao ca Status Word 2. xem thng s 0303. Bit # 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0303, FB STS WORD 1 READY ENABLED STARTED RUNNING ZERO_SPEED ACCELERATE DECELERATE AT_SETPOINT LIMIT SUPERVISION REV_REF REV_ACT PANEL_LOCAL FIELDBUS_LOCAL EXT2_ACT FAULT 0304, FB STS WORD 2 ALARM NOTICE DIRLOCK LOCALLOCK CTL_MODE Reserved Reserved CPY_CTL CPY_REF1 CPY_REF2 REQ_CTL REQ_REF1 REQ_REF2 REQ_REF2EXT ACK_STARTINH ACK_OFF_ILCK 0301, FB CMD WORD 1 STOP START REVERSE LOCAL RESET EXT2 RUN_DISABLE STPMODE_R STPMODE_EM STPMODE_C RAMP_2 RAMP_OUT_0 RAMP_HOLD RAMP_IN_0 RREQ_LOCALLOC TORQLIM2 0302, FB CMD WORD 2 FBLOCAL_CTL FBLOCAL_REF START_DISABLE1 START_DISABLE2 Reserved Reserved Reserved Reserved Reserved Reserved Reserved REF_CONST REF_AVE LINK_ON REQ_STARTINH OFF_INTERLOCK

Parameters

ACS550 Users Manual

105

Code 0305

Description FAULT WORD 1 Ch c bng sao ca Fault Word 1. Khi mt li c kch hot, cc bit tng ng kch hot li t trong Fault Words. Mi li dnh ring bit Phn b trong vng Fault Words. Xem chn Fault listing trn trang 244 Cho mt m t v li. Bng iu khin hin th t trong hex . v d, tt c khng v mt 1 trong Bit 0 hin th nh 0001. tt c khng v mt 1 trong Bit 15 hin th nh 8000. Bit # 0305, FAULT WORD 1 0306, FAULT WORD 2 0307, FAULT WORD 3 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OVERCURRENT DC OVERVOLT DEV OVERTEMP SHORT CIRC Reserved DC UNDERVOLT AI1 LOSS AI2 LOSS MOT OVERTEMP PANEL LOSS ID RUN FAIL MOTOR STALL CB OVERTEMP EXT FAULT 1 EXT FAULT 2 EARTH FAULT Obsolete THERM FAIL OPEX LINK OPEX PWR CURR MEAS SUPPLY PHASE ENCODER ERR OVERSPEED Reserved DRIVE ID CONFIG FILE SERIAL 1 ERR EFB CON FILE FORCE TRIP MOTOR PHASE OUTP WIRING EFB 1 EFB 2 EFB 3 INCOMPATIBLE SW USER LOAD CURVE Reserved Reserved Reserved Reserved Reserved System error System error System error System error System error Param. setting fault

0306

FAULT WORD 2 Ch c bng sao ca Fault Word 2. xem tham s 0305.

0307

FAULT WORD 3 Ch c bng sao ca Fault Word 3. xem tham s 0305.

0308

ALARM WORD 1 Khi mt li c kch hot, cc bit tng ng ng kch hot li t trong Alarm Words. Mi li dnh ring bit phn b trong vng Alarm Words. Bits vn t cho n khi t L t li. (thit lp li bng cch vit khng n t.) bng iu khin hin th t trong hex . v d, tt c khng v mt 1 trong Bit 0 hin th nh 0001. tt c khng v mt 1 trong Bit 15 hin th nh 8000 ALARM WORD 2 Xem thng s 0308.

Bit # 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

0308, ALARM WORD 1 OVERCURRENT OVERVOLTAGE UNDERVOLTAGE DIRLOCK COMM LOSS AI1 LOSS AI2 LOSS PANEL LOSS DEVICE OVERTEMP MOTOR TEMP Reserved MOTOR STALL AUTORESET PFC AUTOCHANGE PFC ILOCK Reserved

0309, ALARM WORD 2 OFF BUTTON PID SLEEP ID RUN Reserved START ENABLE 1 START ENABLE 2 EMERGENCY STOP ENCODER ERROR FIRST START Reserved USER LOAD CURVE START DELAY Reserved Reserved Reserved Reserved

0309

Parameters

106

ACS550 Users Manual

nhm 04: FAULT HISTORY nhm ny lu tr lch s gn y ca thng bo li bi bin tn .


Code 0401 Description LAST FAULT 0 xa lch s li (trn bng iu khin = NO RECORD). n m li ca ghi li cui cng. M li c hin th nh mt tn. Xem phn Fault listing trn trang 244 cho m li v tn. Hin th tn li cho tham s ny c th ngn hn vi tn tng ng trong danh sch li, trong cho thy tn nh c hin th mng hnh hin th li. 0402 FAULT TIME 1 Ngy m trn cc li cui cng xy ra. Hoc l: mt ngy nu ng h thi gian thc ang hot ng. s ca ngy sau khi bt ngun nu thc s ng h thi gian cha s dng, hoc khng c thit lp. 0403 FAULT TIME 2 Thi gian m ti li cui cng xy ra. Hoc l: thi gian thc, trong nh dng hh:mm:ss nu ng h thi gian thc ang hot ng. thi gian k t khi bt ngun (tr nhng ngy bo co trong 0402), trong nh dng hh:mm:ss nu ng h thi gian thc cha s dng, hoc khng c thit lp. nh dng trn Basic Control Panel: thi gian k t khi bt ngun trong 2-giy ticks (tr nhng ngy bo co trong 0402). 30 ticks = 60 seconds. E.g. gi tr 514 bng 17 pht v 8 giy (= 514/30). 0404 0405 0406 0407 0408 0409 0410 0411 0412 0413 SPEED AT FLT Tc ng c (rpm) ti thi im xy ra li mi nht . FREQ AT FLT Tn s (Hz) ti thi im xy ra li mi nht. VOLTAGE AT FLT in p DC bus (V) ti thi im xy ra li mi nht. CURRENT AT FLT Dng in ng c (A) ti thi im xy ra li mi nht. TORQUE AT FLT Momen xon ng c (%)ti thi im xy ra li mi nht. STATUS AT FLT Trng thi bin tn (hex code word) ti thi im xy ra li mi nht. DI 1-3 AT FLT Trng thi cc u vo k thut s 13 ti thi im xy ra li mi nht. DI 4-6 AT FLT Trng thi cc u vo k thut s 46 ti thi im xy ra li mi nht. PREVIOUS FAULT 1 M li ca li cui th hai. Ch c. PREVIOUS FAULT 2 M li ca li cui th ba. Ch c.

Parameters

ACS550 Users Manual

107

nhm 10: START/STOP/DIR Nhm ny: Xc nh cc ngun bn ngoi (EXT1 v EXT2) cho lnh cho php chy, dng v thay i hng . Kha hng hoc cho php iu khin hng.

chn gia hai a im bn ngoi s dng nhm tip theo (tham s1102).
M 1001 m t EXT1 COMMANDS Xc nh v tr kim sot bn ngoi 1 (EXT1) cu hnh ca bt u, dng li v lnh hng. 0 = NOT SEL khng khi ng, dng v lnh hng . 1 = DI1 hai dy khi ng/dng. khi ng/dng thng qua u vo KTS DI1 (DI1 kch hot = khi ng; DI1 kh kch hot = dng). tham s 1003 xc nh hng. chn 1003 = 3 (REQUEST) l ging nh 1003 = 1 (FORWARD). 2 = DI1,2 hai dy khi ng/dng. khi ng/dng thng qua u vo KTS DI1 (DI1 kch hot = khi ng; DI1 kh kch hot = dng). kim sot hng [i hi tham s 1003 = 3 (REQUEST)] l thng qua u vo KTS DI2 (DI2 kch hot = nghch ; khng kch hot = thun ). 3 = DI1P,2P ba dy khi ng/dng. lnh khi ng/dng thng qua nt dng xung ( P vit tc ca xung). khi ng thng qua mt nt nhn thng m kt ni vi u vo KTS DI1. bt u khi ng bin tn, u vo KTS DI2 phi c kch hot trc khi kch xung cho DI1. khi ng nhiu ni nt nhn kt ni song song. dng thng qua mt nt nhn thng ng kt ni vi u vo KTS DI2. dng nhiu ni nt nhn kt ni ni tip thng s 1003 xc nh hng. chn 1003 = 3 (REQUEST) l ging nh 1003 = 1 (FORWARD). 4 = DI1P,2P,3 ba dy khi ng/dng, hng. lnh khi ng/dng thng qua nt dng xung, nh m t cho DI1P,2P. hng kim sot [i hi tham s 1003 = 3 (REQUEST)] l thng qua u vo KTS DI3 (DI3 kch hot = nghch; khng kch hot = thun). 5 = DI1P,2P,3P khi ng thun, khi ng nghch v dng. khi ng v lnh hng ng thi vi hai xung ring bit ( P l vit tc cho xung). lnh khi ng quay thun thng qua mt nt nhn thng m kt ni n u vo KTS DI1 bt u khi ng bin tn, KTS DI3 phi c kch hot trc khi kch xung cho DI1. lnh khi ng quay nghch thng qua mt nt nhn thng m kt ni n u vo KTS DI2. bt u khi ng bin tn, KTS DI3 phi c kch hot trc khi kch xung cho DI2. khi ng nhiu ni nt nhn kt ni song song. dng thng qua mt nt nhn thng ng kt ni vi u vo KTS DI3. dng nhiu ni nt nhn kt ni ni tip. yu cu thng s 1003 = 3 (REQUEST). 6 = DI6 Two-wire Start/Stop. khi ng/dng thng qua u vo KTS DI6 (DI6 kch hot = khi ng; DI6 kh kch hot = dng). thng s 1003 xc nh hng. chn 1003 = 3 (REQUEST) l ging nh 1003 = 1 (FORWARD). 7 = DI6,5 Two-wire Start/Stop/Direction. khi ng/dng thng qua u vo KTS DI6 (DI6 kch hot = khi ng; DI6 kh kch hot = dng). kim sot hng [yu cu thng s 1003 = 3 (REQUEST)] l thng qua u vo KTS DI5. (DI5 DI6 kch hot = khi ng; kh kch hot = dng). 8 = KEYPAD bng iu khin. khi ng/dng v lnh hng thng qua bng iu khin EXT1 ang hot ng. kim sot hng yu cu tham s 1003 = 3 (REQUEST). 9 = DI1F,2R khi ng/dng/lnh hng thng qua DI1 v DI2 kt hp. khi ng thun = DI1 kch hot v DI2 khng kch hot. khi ng nghch = DI1 khng kch hot v DI2 kch hot. dng = c hai DI1 v DI2 kch hot, hoc c hai khng kch hot. yu cu tham s 1003 = 3 (REQUEST). 10 = COMM Assigns the fieldbus Command Word nh ngun cho khi ng/dng v lnh hng. Bits 0,1, 2 of Command Word 1 (tham s 0301) kch hot khi ng/dng v lnh hng. xem hng dn s dng Fieldbus c hng dn chi tit.

Parameters

108

ACS550 Users Manual

Code Description 11 = TIMED FUNC 1. ch nh kim sot khi ng dng n chc nng ng h 1 (kch hot chc nng hn gi = START; kh kch hot chc nng hn gi = STOP). xem nhm 36: TIMED FUNCTIONS. 1214 = TIMED FUNC 24 ch nh kim sot khi ng dng n chc nng ng h 24. xem TIMED FUNC 1 trn. 1002 EXT2 COMMANDS Xc nh v tr kim sot bn ngoi 2 (EXT2) cu hnh ca khi ng, dng, v lnh hng . xem thng s 1001 EXT1 COMMANDS trn . 1003 DIRECTION Xc nh kim sot hng quay ca ng c. 1 = FORWARD chiu quay l c nh theo hng thun. 2 = REVERSE chiu quay l c nh theo hng nghch. 3 = REQUEST hng quay c th thay i trn lnh. 1004 JOGGING SEL Xc nh tn hiu kch hot chc nng chy nhp. Chy nhp s dng Constant Speed 7 (thng s 1208) cho tc tham chiu v cp dc 2 (thng s 2205 v 2206) cho tng tc v gim tc. Khi tn hiu kch hot chy nhp b mt , bin tn s dng dc dng li gim tc n tc khng, thm ch nu dc dng c s dng trong hot ng bnh thng (thng s 2102). Tnh trng chy nhp c th c tham s ha n u ra relay (thng s 1401). Trng thi chy nhp cng gp DCU tnh trng bin dng bit 21. 0 = NOT SEL v hiu ha chc nng chy nhp. 1 = DI1 kch hot/kh kch hot chy nhp da trn trng thi ca DI1 (DI1 kch hot = chy nhp hot ng; DI1 kh kch hot =chy nhp khng hot ng). 26 = DI2DI6 kch hot chy nhp da trn trng thi ca chn u vo KTS. xem DI1 trn. -1 = DI1(INV) kch hot chy nhp da trn trng thi ca DI1 (DI1 kch hot = chy nhp khng hot ng; DI1 kh kch hot =chy nhp hot ng). -2-6 = DI2(INV)DI6(INV) kch hot chy nhp da trn trng thi ca chn u vo KTS .xem DI1(INV) trn.

Parameters

ACS550 Users Manual

109

Nhm 11: REFERENCE SELECT Nhm ny xc nh: lm th no bin tn chn gia cc ngun lnh . c im v ngun cho REF1 v REF2.
Code Description 1101 KEYPAD REF SEL

Chn iu khin tham chiu trong ch kim sot cc b.

1 = REF1(Hz/rpm) xc nh loi ca tham chiu trn nhm 9904 MOTOR CTRL MODE. tc tham chiu (rpm) nu 9904 = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ). tn s tham chiu (Hz) nu 9904 = 3 (SCALAR:FREQ). 2 = REF2(%) 1102 EXT1/EXT2 SEL Xc nh ngun chn gia hai a im kim sot ngoi EXT1 hoc EXT2. nh vy, xc nh ngun cho khi ng/dng/lnh hng v tn hiu tham chiu. 0 = EXT1 chn kim sot v tr bn ngoi 1 (EXT1). xem thng s 1001 EXT1 COMMANDS cho EXT1 khi ng/dng /xc nh hng. xem thng s 1103 REF1 SELECT cho EXT1 xc nh tham chiu . 1 = DI1 quy nh kim sot n EXT1 hoc EXT2 da vo trng thi ca DI1 (DI1 kch hot = EXT2; DI1 kh kch hot = EXT1). 26 = DI2DI6 quy nh kim sot n EXT1 hoc EXT2 da vo trng thi ca chn u vo KTS. xem DI1 trn. 7 = EXT2 chn kim sot v tr bn ngoi 2 (EXT2). xem thng s 1002 EXT2 COMMANDS cho EXT2 Khi ng/dng /xc nh hng. xem thng s 1106 REF2 SELECT cho EXT2 xc nh tham chiu. 8 = COMM quy nh kim sot ca bin tn thng qua im kim sot bn ngoi EXT1 hoc EXT2 da trn kim sot t fieldbus. Bit 5 ca Command Word 1 (thng s 0301) xc nh hot ng v tr kim sot bn ngoi (EXT1 hoc EXT2). xem hng dn s dng Fieldbus c hng dn chi tit. 9 = TIMED FUNC 1 quy nh kim sot n EXT1 hoc EXT2 da vo trng thi ca chc nng ng h (chc nng ng h Kch hot = EXT2; chc nng ng h khng kch hot = EXT1). xem Group 36: TIMED FUNCTIONS. 1012 = TIMED FUNC 24 quy nh kim sot n EXT1 hoc EXT2 da vo trng thi ca chc nng ng h. xem TIMED FUNC 1 trn. -1 = DI1(INV) quy nh kim sot n EXT1 hoc EXT2 da vo trng thi ca DI1 (DI1 Kch hot = EXT1; DI1 kh Kch hot = EXT2). -2-6 = DI2(INV)DI6(INV) quy nh kim sot n EXT1 hoc EXT2 da vo trng thi ca chn u vo KTS. xem DI1(INV) trn. 1103 REF1 SELECT

Chn ngun tn hiu cho tham chiu ngoi REF1.

EXT REF

1 MAX

0 = KEYPAD xc nh bng iu khin nh tham chiu ngun . EXT REF 1 MIN 1 = AI1 xc nh u vo tng t 1 (AI1) nh tham chiu ngun . 2 = AI2 xc nh u vo tng t 2 (AI2) nh tham chiu ngun - EXT REF 1 MIN . 3 = AI1/JOYST xc nh u vo tng t 1 (AI1), cu hnh cho hot ng iu khin, nh tham chiu ngun. - EXT REF 1 MAX tn hiu u vo nh nht chy bin tn ti tham chiu ln nht 2 V / 4 mA theo hng ngc li. xc nh nh nht bng cch s dng 0 V / 0 mA tham s 1104. EXT REF 1 MIN tn hiu u vo ln nht chy bin tn ti tham chiu ln nht theo hng thun. Xc nh ln nht bng cch s dng - EXT REF 1 MIN tham s 1105. Hysteresis 4% of full scale yu cu thng s 1003 = 3 (REQUEST).

10 V / 20 mA

-2%

+2%

CNH BO! Bi v vo thp ca tham chiu phm vi lnh hot ng o ngc hon ton, khng s dng 0 V l phn cui thp ca phm vi. Lm nh vy nu tn hiu iu khin b mt (l 0 V u vo) kt qu l hot ng o ngc hon ton . thay vo , s dng sau y thit lp mt mass ca cc u vo tng t gy ra mt li, dng bin tn: t thng s 1301 MINIMUM AI1 (1304 MINIMUM AI2) ti 20% (2 V hoc 4 mA). t thng s 3021 AI1 FAULT LIMIT n gi tr 5% hoc cao hn. t thng s 3001 AI<MIN FUNCTION n 1 (FAULT). 4 = AI2/JOYST xc nh u vo tng t 2 (AI2), cu hnh cho hot ng iu khin, nh ngun tham kho. xem m t trn (AI1/JOYST).

Parameters

110

ACS550 Users Manual

Code

Description 5 = DI3U,4D(R) xc nh u vo KTS nh ngun tham chiu tc (potentiometer kim sot ng c). u vo KTS DI3 tng tc (U vit tc ca ln). u vo KTS DI4 gim tc (D vit tc ca xung). lnh Stop resets cc thng s n bng khng (R vit tc ca reset). tham s 2205 ACCELER TIME 2 iu khin tn hiu tham chiu ca thay i tc . 6 = DI3U,4D tng t nh trn (DI3U,4D(R)), ngoi tr : mt lnh dng khng reset tham chiu n khng . tham chiu c lu. khi khi ng li bin tn, dc ng c ln (ti chn dc tng tc) n tham chiu c lu. 7 = DI5U,6D tng t nh trn (DI3U,4D), ngoi tr DI5 v DI6 l nhng u vo KTS c chn. 8 = COMM xc nh fieldbus nh ngun tham chiu . 9 = COMM+AI1 xc nh mt fieldbus v u vo KTS 1 (AI1) kt hp nh ngun tham kho. xem u vo tng t hiu chnh di y. 10 = COMM*AI1 xc nh mt fieldbus v u vo KTS 1 (AI1) kt hp nh ngun tham kho. xem u vo tng t hiu chnh di y. 11 = DI3U,4D(RNC) tng t nh DI3U,4D(R) trn, ngoi tr : thay i m ngun iu khin (EXT1 n EXT2, EXT2 n EXT1, LOC n REM) khng sao chp tham chiu. 12 = DI3U,4D(NC) tng t nh DI3U,4D trn, ngoi tr : thay i m ngun iu khin (EXT1 n EXT2, EXT2 n EXT1, LOC n REM) khng sao chp tham chiu. 13 = DI5U,6D(NC) tng t nh DI5U,6D trn, ngoi tr : thay i m ngun iu khin (EXT1 n EXT2, EXT2 n EXT1, LOC n REM) khng sao chp tham chiu. 14 = AI1+AI2 xc nh u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham kho. xem tham chiu u vo tng t chnh di y. 15 = AI1*AI2 xc nh u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham kho. xem tham chiu u vo tng t chnh di y. 16 = AI1-AI2 xc nh u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham kho. xem tham chiu u vo tng t chnh di y. 17 = AI1/AI2 xc nh u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham kho. xem tham chiu u vo tng t chnh di y. 20 = KEYPAD(RNC) xc nh bng iu khin nh ngun tham kho. mt lnh dng reset tham chiu n khng (R vit tc ca reset.). thay i m ngun iu khin (EXT1 n EXT2, EXT2 n EXT1) khng sao chp tham chiu. 21 = KEYPAD(NC) xc nh bng iu khin nh ngun tham kho. mt lnh dng khng reset tham chiu n khng . tham chiu c lu. thay i m ngun iu khin (EXT1 n EXT2, EXT2 n EXT1) khng sao chp tham chiu. Chnh tham chiu u vo tng t Gi tr tham s 9, 10 v 1417 s dng cng thc trong bng sau . Value setting C+B C*B C-B C/B Calculation of the AI reference C gi tr + (B gi tr - 50% ca gi tr tham chiu) C gi tr (B gi tr / 50% ca gi tr tham chiu) (C gi tr + 50% ca gi tr tham chiu) - B gi tr (C gi tr 50% ca gi tr tham chiu) / B gi tr 120 100 80 60 40 20 0 16 (-) 0 100% B 9, 14 (+) 10, 15 (*)

Trng hp: C = gi tr tham kho chnh ( = COMM cho cc gi tr 9, 10 v = AI1 cho cc gi tr 1417). B = tham chiu chnh ( = AI1 cho cc gi tr 9, 10 and = AI2 cho cc gi tr 1417). V d: Con s ny cho thy ngun tham chiu cc ng cong cho gi tr Thit lp 9, 10 v 1417, trng hp: C = 25%. P 4012 SETPOINT MIN = 0. P 4013 SETPOINT MAX = 0. B dao ng dc theo trc ngang.

17 (/)

Parameters

ACS550 Users Manual

111

m 1104

m t REF1 MIN Thit lp nh nht cho tham chiu ngoi 1. tn hiu tng t u vo nh nht (nh phn trm ca tn hiu y ca in p hoc amper) tng ng vi REF1 MIN trong Hz/rpm. thng s 1301 MINIMUM AI1 hoc 1304 MINIMUM AI2 thit lp tn hiu tng t u vo nh nht. cc thng s ny (tham chiu v ci t tng t min. v max. ) cung cp t l iu chnh lch cho tham chiu . Ext ref P 1105 (MAX)

1105

REF1 MAX Thit lp ln nht cho tham chiu ngoi 1. tn hiu tng t u vo ln nht (nh phn trm ca tn hiu y ca in p hoc amper) tng ng vi REF1 MAX trong Hz/rpm. thng s 1302 MAXIMUM AI1 hoc 1305 MAXIMUM AI2 thit lp tn hiu tng t u vo ln nht.

P 1104 (MIN) P 1301 or 1304 Ext ref P 1104 (MIN)

u vo tn hiu tng t P 1302 or 1305

P 1105 (MAX) P 1301 hoc 1304 1106 REF2 SELECT Chn tn hiu ngun cho tham chiu ngoi REF2. 017 tng t nh tham s 1103 REF1 SELECT. 19 = PID1OUT tham chu c ly t u ra PID1. xem nhm 40: PROCESS PID SET 1 v nhm 41: PROCESS PID SET 2. 2021 tng t nh tham s 1103 REF1 SELECT. 19=PID1 117 2021 1107 REF2 MIN Chn tn hiu nh nht cho tham chiu ngoi 2. cc tn hiu u vo nh nht (trong volt hoc amper) tng ng vi REF2 MIN trong %. thng s 1301 MINIMUM AI1 hoc 1304 MINIMUM AI2 thit lp tn hiu tng t u vo nh nht. thit lp thng s tn s tham chiu nh nht. gi tr l t l phn trm ca : tn s ln nht hoc tc . qu trnh tham chic ln nht . momen xon danh nh. 1108 REF2 MAX Chn tn hiu ln nht cho tham chiu ngoi 2. cc tn hiu u vo ln nht (trong volt hoc amper ) tng ng v REF2 MAX trong %. thng s 1302 MAXIMUM AI1 hoc 1305 MAXIMUM AI2 thit lp tn hiu tng t u vo ln nht thit lp thng s tn s tham chiu ln nht. gi tr l t l phn trm ca: tn s ln nht hoc tc . qu trnh tham chic ln nht . momen xon danh nh.
REF2 SELECT

u vo P 1302 tn hiu tng t hoc 1305

LIMIT
MAX MIN

Nu PFC c s dng (1107, 1108) (1107, 1108) PFC

Parameters

112

ACS550 Users Manual

nhm 12: CONSTANT SPEEDS Nhm ny xc nh mt tp hp cc tc khng i. ni chung : Bn c th lp trnh ln n 7 tc khng i, tm t 0500 Hz hoc 030000 rpm. Cc gi tr phi dng (khng c gi tr tc m vi tc khng i). Chn tc khng i c b qua nu : iu khin momen xon c kch hot .hoc Qu trnh PID tham chiu c theo sau, hoc Bin tn trong ch kim sot cc b, hoc PFC (iu khin bm-qut) c kch hot. Ch : thng s 1208 CONST SPEED 7 acts cng nh gi mt li tc m c th c kch hot nu tn hiu iu khin mt . v d, xem thng s 3001 AI<MIN FUNCTION, 3002 PANEL COMM ERR v 3018 COMM FAULT FUNC.
Code Description 1201 CONST SPEED SEL Xc nh cc yu t u vo KTS dng chn tc khng i. Xem din gii chung trong phn gii thiu. 0 = NOT SEL v hiu ha chc nng tc khng i . 1 = DI1 chn tc khng i 1 vi u vo KTS DI1. vi u vo KTS kch hot= Constant Speed 1 kch hot . 26 = DI2DI6 chn Constant Speed 1 vi u vo KTS DI2DI6. xem trn. 7 = DI1,2 chn mt trong ba tc khng i (13) s dng DI1 v DI2. s dng hai u vo KTS, nh xc nh di y (0 = DI kh kch hot, 1 = DI kch hot ):
DI1 DI2

0 1 0 1

0 0 1 1

Function Khng tc khng i tc khng i 1 (1202) tc khng i 2 (1203) tc khng i 3 (1204)

c th c thit lp nh gi mt li tc , n c kch hot nu tn hiu kim sot b mt . Tham kho thng s 3001 AI<MIN chc nng v thng s 3002 PANEL COMM ERR. 8 = DI2,3 chn mt trong ba tc khng i (13) s dng DI2 v DI3. xem trn (DI1,2) cho m. 9 = DI3,4 chn mt trong ba tc khng i (13) s dng DI3 v DI4. xem trn (DI1,2) cho m. 10 = DI4,5 chn mt trong ba tc khng i (13) s dng DI4 v DI5. xem trn (DI1,2) cho m. 11 = DI5,6 chn mt trong ba tc khng i (13) s dng DI5 v DI6. xem trn (DI1,2) cho m. 12 = DI1,2,3 chn mt trong by tc khng i (17) s dng DI1, DI2 v DI3. s dng ba u vo s, nh xc nh di y (0 = DI kh kch hot, 1 = DI kch hot): DI1 0 1 0 1 0 1 0 1 DI2 0 0 1 1 0 0 1 1 DI3 0 0 0 0 1 1 1 1 Function Khng tc khng i tc khng i 1 (1202) tc khng i 2 (1203) tc khng i 3 (1204) tc khng i 4 (1205) tc khng i 5 (1206) tc khng i 6 (1207) tc khng i 7 (1208)

Parameters

ACS550 Users Manual

113

Code

Description 13 = DI3,4,5 chn mt trong by tc khng i (17) s dng DI3, DI4 v DI5. xem trn (DI1,2,3) cho m. 14 = DI4,5,6 chn mt trong by tc khng i (17) s dng DI4, DI5 v DI6. xem trn (DI1,2,3) cho m. 1518 = TIMED FUNC 14 chn tc khng i 1 khi chc nng ng h c kch hot. xem nhm 36: TIMED FUNCTIONS. 19 = TIMED FUN1&2 chn mt tc khng i ty thuc vo tnh trng chc nng ng h 1 & 2. xem thng s 1209. -1 = DI1(INV) chn tc khng i 1 vi u vo KTS DI1. ngc hot ng: u vo KTS kh kch hot = tc khng i 1 kch hot . -2- 6 = DI2(INV)DI6(INV) chn tc khng i 1 vi u vo KTS. Xem trn. -7 = DI1,2(INV) chn mt trong ba tc khng i (13) s dng DI1 v DI2. ngc hot ng s dng hai u vo KTS, nh mc nh di (0 = DI kh kch hot, 1 = DI kch hot ):
DI1 DI2

1 0 1 0

1 1 0 0

Function Khng tc khng i tc khng i 1 (1202) tc khng i 2 (1203) tc khng i 3 (1204)

-8 = DI2,3(INV) chn mt trong ba tc khng i (13) s dng DI2 v DI3. xem trn (DI1,2(INV)) cho m. -9 = DI3,4(INV) chn mt trong ba tc khng i (13) s dng DI3 v DI4. xem trn (DI1,2(INV)) cho m. -10 = DI4,5(INV) chn mt trong ba tc khng i (13) s dng DI4 v DI5. xem trn (DI1,2(INV)) cho m. -11 = DI5,6(INV) chn mt trong ba tc khng i (13) s dng DI5 v DI6. xem trn (DI1,2(INV)) cho m. -12 = DI1,2,3(INV) chn mt trong by tc khng i (17) s dng DI1, DI2 v DI3. ngc hot ng s dng ba u vo KTS, nh mc nh di (0 = DI kh kch hot, 1 = DI kch hot):
DI1 DI2 DI3

1 0 1 0 1 0 1 0

1 1 0 0 1 1 0 0

1 1 1 1 0 0 0 0

Function Khng tc khng i tc khng i 1 (1202) tc khng i 2 (1203) tc khng i 3 (1204) tc khng i 4 (1205) tc khng i 5 (1206) tc khng i 6 (1207) tc khng i 7 (1208)

-13 = DI3,4,5(INV) chn mt trong by tc khng i (17) s dng DI3, DI4 v DI5. xem trn (DI1,2,3(INV)) cho m. -14 = DI4,5,6(INV) chn mt trong by tc khng i (17) s dng DI4, DI5 v DI6. xem trn (DI1,2,3(INV)) cho m. 1202 CONST SPEED 1 t gi tr cho tc khng i 1. phm vi v n v ph thuc vo tham s 9904 MOTOR CTRL MODE. phm vi: 030000 rpm khi 9904 = 1 (VECTOR:sPEED) hoc 2 (VECTOR:TORQ). phm vi: 0500 Hz khi 9904 = 3 (SCALAR:FREQ). CONST SPEED 2CONST SPEED 7 Ci t mi b gi tr cho mt tc khng i. xem CONST SPEED 1 trn. tc khng i 7 cng c s dng nh tc chy nhp. xem thng s 1004 JOGGING SEL.

1203 1208

Parameters

114

ACS550 Users Manual

Code Description 1209 TIMED MODE SEL Xc nh kch hot chc nng hn gi, ch tc khng i. Chc nng hn gi c th c s dng thay i gia cc tham chiu ngoi v mt trong ba tc khng i, hoc thay i gia ln nht ca chn 4 tc , i.e. tc khng i 1, 2, 3 v 4. 1 = EXT/CS1/2/3 chn mt tc bn ngoi khi khng c chc nng hn gi c kch hot, chn tc khng i 1 ch khi chc nng hn gi 1 c kch hot, chn tc khng i 2 ch khi chc nng thi gian 2 ang hot ng v chn tc khng i 3 khi c hai chc nng hn gi 1 v 2 ang hot ng .
TIMER1 TIMER2

0 1 0 1

0 0 1 1

Function Tham chiu ngoi tc khng i 1 (1202) tc khng i 2 (1203) tc khng i 3 (1204)

2 = CS1/2/3/4 chn tc khng i 1 khi hn gi khng c kch hot, chn tc khng i 2 ch khi chc nng hn gi 1 l hot ng, chn tc khng i 3 ch khi chc nng hn gi 2 l hot ng, chn tc khng i 4 khi c hai chc nng hn gi l hot ng .
TIMER1 TIMER2

0 1 0 1

0 0 1 1

Function tc khng i 1 (1202) tc khng i 2 (1203) tc khng i 3 (1204) tc khng i 4 (1205)

Parameters

ACS550 Users Manual

115

nhm 13: ANALOG INPUTS Nhm ny xc nh gii hn b lc cho cho cc u vo tng t.


Code 1301 Description MINIMUM AI1 Xc nh gi tr nh l mt phn trm ca dy tn hiu ton tng t. Xem v d di y.

Xc nh gi tr ti thiu ca u vo tng t.

Cc tn hiu tng t u vo ti thiu tng ng vi 1.104 REF1 MIN hoc MIN REF2 1107 MINIMUM AI khng th ln hn MAXIMUM AI. cc thng s ny (ci t tham chiu v tng t min. v max.) cung cp t l v iu chnh. b cho tham chiu. xem hnh thng s 1104. V d. thit lp gi tr u vo tng t ti thiu 4 mA: cu hnh u vo tng t cho tn hiu dng in 020 mA. tnh ti thiu (4 mA) nh phn trm ca y (20 mA) = 4 mA / 20 mA 100% = 20%
1302 MAXIMUM AI1

Xc nh gi tr ti a ca u vo tng t. Xc nh gi tr nh l mt phn trm ca dy tn hiu ton tng t. Cc tn hiu tng t u vo ti a tng ng vi 1105 REF1 MAX hoc 1108 REF2 MAX.
xem hnh thng s 1104. 1303 FILTER AI1 % 100 63

Xc nh thi gian lc lin tc u vo tng t 1 (AI1). cc tn hiu c lc ln n 63% ca bc thay i trong thi gian quy nh .

khng lc tn hiu

Lc tn hiu

Hng s thi gian


1304 MINIMUM AI2

Xc nh gi tr ti thiu ca u vo tng t .
xem MINIMUM AI1 trn. 1305 MAXIMUM AI2

Xc nh gi tr ti a ca u vo tng t
xem MAXIMUM AI1 trn. 1306 FILTER AI2

Xc nh thi gian lc lin tc u vo tng t 2 (AI2).


xem FILTER AI1 trn.

Parameters

116

ACS550 Users Manual

nhm 14: RELAY OUTPUTS Nhm ny xc nh mi iu kin kch hot ca cc relay u ra


Code Description 1401 RELAY OUTPUT 1 Xc nh bin c hoc iu kin kch hot relay 1 phng thc u ra relay 1 l g . 0 = NOT SEL Relay khng c s dng khng c ng in . 1 = READY ng in cho relay khi bin tn sn sng hot ng. yu cu: tn hiu cho php chy hin ti. khng tn ti li. ngun cung cp l trong phm vi . lnh dng khn cp khng on . 2 = RUN ng in cho relay khi bin tn ang chy . 3 = FAULT(-1) ng in cho ngun in relay . khng ng in khi li xy ra. 4 = FAULT ng in cho relay khi mt li c kch hot. 5 = ALARM ng in cho relay khi mt bo ng c kch hot. 6 = REVERSED ng in cho relay khi ng c quay theo hng ngc. 7 = STARTED ng in cho relay khi bin tn nhn c lnh khi ng (ngay c khi khng c tn hiu cho php chy). khngng in cho khi bin tn nhn c lnh dng hoc li xy ra . 8= SUPRV1 OVER ng in cho relay khi tn hiu gim st u tin thng s (3201) vt qu gii hn (3203). xem Group 32: SUPERVISION bt u trn trang 144. 9 = SUPRV1 UNDER ng in cho relay khi tn hiu gim st u tin thng s (3201) gim di mc gii hn (3202). xem Group 32: SUPERVISION bt u trn trang 144. 10 = SUPRV2 OVER ng in cho relay khi tn hiu gim st th hai thng s (3204) vt qu gii hn (3206). xem Group 32: SUPERVISION bt u trn trang 144. 11 = SUPRV2 UNDER ng in cho relay khi tn hiu gim st th hai thng s (3204) gim di mc gii hn (3205). xem Group 32: SUPERVISION bt u trn trang 144. 12 = SUPRV3 OVER ng in cho relay khi tn hiu gim st th ba thng s (3207) vt qu gii hn (3209). xem Group 32: SUPERVISION bt u trn trang 144. 13 = SUPRV3 UNDER ng in cho relay khi tn hiu gim st th ba thng s (3207) gim di mc gii hn (3208). xem Group 32: SUPERVISION bt u trn trang 144. 14 = AT SET POINT ng in cho relay khi tn s u ra bng vi tn s tham chiu. 15 = FAULT(RST) ng in cho relay bin tn trong tnh trng li v s reset sau khi t ng lp trnh -reset tr. xem thng s 3103 DELAY TIME. 16 = FLT/ALARM ng in cho relay khi xy ra li hoc bo ng. 17 = EXT CTRL ng in cho relay khi iu khin bn ngoi c chn. 18 = REF 2 SEL ng in cho relay khi EXT2 c chn . 19 = CONST FREQ ng in cho relay khi tc khng i c chn. 20 = REF LOSS ng in cho relay khi tham chiu hoc kim sot hot ng b mt. 21 = OVERCURRENT ng in cho relay khi mt bo ng qu dng hoc li xy ra. 22 = OVERVOLTAGE ng in cho relay khi mt bo ng qu p hoc li xy ra. 23 = DRIVE TEMP ng in cho relay khi bin tn hoc board iu khin qu nhit hoc li xy ra. 24 = UNDERVOLTAGE ng in cho relay khi mt bo ng thp p hoc li xy ra. 25 = AI1 LOSS ng in cho relay khi tn hiu AI1 b mt. 26 = AI2 LOSS ng in cho relay khi tn hiu AI2 b mt. 27 = MOTOR TEMP ng in cho relay khi bo ng qu nhit ng c hoc li xy ra. 28 = STALL ng in cho relay khi mt bo ng ngng chy hoc li xy ra. 30 = PID SLEEP ng in cho relay khi chc nng ch PID c hot ng. 31 = PFC s dng relay khi ng /dng ng c trong kim sot PFC (xem Group 81: PFC CONTROL). s dng ty chn ny ch khi kim sot PFC c s dng. ch kch hot / v hiu ha khi bin tn khng hot ng. 32 = AUTOCHANGE ng in cho relay khi PFC hot ng autochange c thc hin. s dng ty chn ny ch khi kim sot PFC c s dng. 33 = FLUX READY ng in cho relay khi ng c c t ha v c th cung cp momen xon danh nh (ng c t n t ha danh nh). 34 = USER MACRO 2 ng in cho relay khi User Parameter Set 2 ang hot ng .

Parameters

ACS550 Users Manual

117

Code Description 35 = COMM ng in cho relay da trn thng tin t truyn thng fieldbus. Fieldbus vit m nh phn tham s 0134 c th ng in cho relay 1relay 6 theo sau y: Par. 0134 0 1 2 3 4 562 63 Binary 000000 000001 000010 000011 000100 111111 RO6 0 0 0 0 0 1 RO5 0 0 0 0 0 1 RO4 0 0 0 0 0 1 RO3 0 0 0 0 1 1 RO2 RO1 0 0 0 1 1 0 1 1 0 0 1 1

0 = khng ng in cho relay, 1 = ng in cho relay. 36 = COMM(-1) ng in cho relay da trn thng ti t truyn thng fieldbus. Fieldbus vit m nh phn tham s 0134 c th ng in cho relay 1relay 6 theo sau y: Par. 0134 0 1 2 3 4 562 63 Binary 000000 000001 000010 000011 000100 111111 RO6 1 1 1 1 1 0 RO5 1 1 1 1 1 0 RO4 1 1 1 1 1 0 RO3 1 1 1 1 0 0 RO2 RO1 1 1 1 0 0 1 0 0 1 1 0 0

0 = khng ng in cho relay, 1 = ng in cho relay 37 = TIMED FUNC 1 ng in cho relay khi chc nng hn gi 1 l hot ng. xem nhm 36: TIMED FUNCTIONS. 3840 = TIMED FUNC 24 ng in cho relay khi chc nng hn gi 24 l hot ng. xem TIMED FUNC 1 trn. 41 = MNT TRIG FAN ng in cho relay khi b m qut lm mt c kch hot. xem nhm 29: MAINTENANCE TRIG. 42 = MNT TRIG REV ng in cho relay khi my m vng quay c kch hot. xem nhm 29: MAINTENANCE TRIG. 43 = MNT TRIG RUN ng in cho relay khi m thi gian chy c kch hot. xem nhm 29: MAINTENANCE TRIG. 44 = MNT TRIG MWH ng in cho relay khi b m MWh c kch hot. xem nhm 29: MAINTENANCE TRIG. 46 = START DELAY ng in cho relay khi b khi ng tr c kch hot. 47 = USER LOAD C ng in cho relay khi s dng ti ng cong li hoc bo ng xy ra. 52 = JOG ACTIVE ng in cho relay khi chc nng chy nhp ang hot ng . 1402 RELAY OUTPUT 2 Xc nh bin c hoc iu kin kch hot relay 2 phng thc u ra relay 2 l g. xem 1401 RELAY OUTPUT 1. 1403 RELAY OUTPUT 3 Xc nh bin c hoc iu kin kch hot relay 3 phng thc u ra relay 3 l g xem 1401 RELAY OUTPUT 1. 1404 RO 1 ON DELAY Xc nh chuyn i ng tr cho relay 1. On / off c b qua khi u ra 1401 c t n PFC. 1405 RO 1 OFF DELAY Xc nh chuyn i tc tr cho relay 1. On / off c b qua khi u ra 1401 c t n PFC. 1406 RO 2 ON DELAY Xc nh chuyn i ng tr cho relay 2. xem RO 1 ON DELAY. 1407 RO 2 OFF DELAY Xc nh chuyn i tc tr cho relay 2. xem RO 1 OFF DELAY. 1408 RO 3 ON DELAY Xc nh chuyn i ng tr cho relay 3. xem RO 1 ON DELAY. Control event

Relay status 1404 ON DELAY 1405 OFF DELAY

Parameters

118

ACS550 Users Manual

Code 1409

Description RO 3 OFF DELAY Xc nh chuyn i tc tr cho relay 3. xem RO 1 OFF DELAY.

1410 RELAY OUTPUT 46 Xc nh bin c hoc iu kin kch hot relay 46 phng thc u ra relay 46. l g 1412 xem 1401 RELAY OUTPUT 1. 1413 RO 4 ON DELAY Xc nh chuyn i ng tr cho relay 4. xem RO 1 ON DELAY. 1414 RO 4 OFF DELAY Xc nh chuyn i tc tr cho relay 4. xem RO 1 OFF DELAY. 1415 RO 5 ON DELAY Xc nh chuyn i ng tr cho relay 5. xem RO 1 ON DELAY. RO 5 OFF DELAY Xc nh chuyn i tc tr cho relay 5. xem RO 1 OFF DELAY. 1417 RO 6 ON DELAY Xc nh chuyn i ng tr cho relay 6. xem RO 1 ON DELAY. 1418 RO 6 OFF DELAY Xc nh chuyn i tc tr cho relay 6. xem RO 1 OFF DELAY.

1416

Parameters

ACS550 Users Manual

119

nhm 15: ANALOG OUTPUTS Nhm xy xc nh u vo tng t u ra ca bin tn (tn hiu dng in). u ra tng t bin tn c th l : bt k tham s trong nhm 01: OPERATING DATA gii hn lp trnh gi tr nh nht v ln nht ca u ra dng in thu nh (v/hoc ngc) bng cch xc nh gi tr nh nht v ln nht ca tham s ngun (hoc ni dung). Xc nh mt gi tr ln nht (tham s 1503 hoc 1509) l t hn dung lng gi tr ln nht (tham s 1502 hoc 1508) kt qu ti mt u ra ngc. lc.
Code Description 1501 AO1 CONTENT SEL Xc nh kt ni cho u ra AO1. 99 = EXCITE PTC cung cp mt ngun dng cho cm bin PTC. u ra = 1.6 mA. xem nhm 35: MOTOR TEMP MEAS. 100 = EXCITE PT100 cung cp mt ngun dng cho cm bin PT100. u ra = 9.1 mA. xem nhm 35: MOTOR TEMP MEAS. 101159 u ra tng ng vi tham s trong nhm 01: OPERATING DATA. cc thng s c xc nh bi gi tr (gi tr 102 = tham s 0102) 1502 AO1 CONTENT MIN t gi tr kt ni nh nht . kt ni c chn bi tham s 1501. gi tr nh nht tham s n gi tr kt ni nh nht c chuyn sang mt u ra tng t . cc thng s (ci t kt ni v dng in min. v max. ) cung cp t l v iu chnh b cho u ra. Xem hnh . 1503 AO1 CONTENT MAX t gi tr kt ni ln nht kt ni c chn bi tham s 1501. gi tr ln nht tham s n gi tr kt ni ln nht c chuyn sang mt u ra tng t. 1504 1505 1506 MINIMUM AO1 Ci t u ra dng in nh nht. MAXIMUM AO1 Ci t u ra dng in ln nht. FILTER AO1 Xc nh thi gian lc lin tc cho AO1. cc tn hiu c lc ln n 63% ca bc thay i trong thi gian quy nh. xem hnh trong tham s 1303. 1507 1508 1509 1510 AO2 CONTENT SEL Xc nh kt ni cho u ra tn hiu tng t AO2. xem AO1 CONTENT SEL trn. AO2 CONTENT MIN Thit lp gi tr kt ni nh nht. xem AO1 CONTENT MIN trn. AO2 CONTENT MAX Thit lp gi tr kt ni ln nht. xem AO1 CONTENT MAX trn. MINIMUM AO2 Thit lp dng in u ra nh nht . xem MINIMUM AO1 trn. P 1504 / P 1510
AO CONTENT

AO (mA) P 1505 / P 1511

P 1504 / P 1510 P 1502 / 1508 AO (mA) P 1505 / P 1511

AO CONTENT

P 1503 / 1509

P 1503 / 1509

P 1502 / 1508

Parameters

120

ACS550 Users Manual

Code Description 1511 1512 MAXIMUM AO2 Thit lp dng in u ra ln nht. xem MAXIMUM AO1 trn. FILTER AO2 Xc nh thi gian lc lin tc cho AO2. xem FILTER AO1 trn.

Parameters

ACS550 Users Manual

121

nhm 16: SYSTEM CONTROLS nhm ny xc nh cc bin ca kha cc cp h thng, reset v cho php.
Code Description 1601 RUN ENABLE Chn ngun tn hiu cho php chy. 0 = NOT SEL cho php bin tn khi ng m khng c mt tn hiu cho php chy bn ngoi. 1 = DI1 xc nh u vo KTS DI1 nh tn hiu cho php chy . k thut s u vo ny phi c kch hot cho php chy. nu in p thp v kh kch hot u vo KTS ny, bin tn s theo dc dng v khng th khi ng Cho n khi tn hiu cho php chy tip tc. 26 = DI2DI6 xc nh u vo KTS DI2DI6 nh tn hiu cho php chy. xem DI1 trn. 7 = COMM Assigns the fieldbus Command Word nh ngun tn hiu cho php chy. Bit 6 ca Command Word 1 (thng s 0301) kch hot tn hiu v hiu ha chy. xem fieldbus hng dn s dng c hng dn chi tit . -1 = DI1(INV) xc nh ngc du vo KTS DI1 nh tn hiu cho php chy. u vo KTS ny phi khng c kch hot cho cho php chy. Nu u vo KTS kch hot, bin tn s theo dc dng v khng th khi ng cho n khi tn hiu cho php chy tip tc . -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo KTS DI2DI6 nh tn hiu cho php chy. xem DI1(INV) trn. 1602 PARAMETER LOCK

Quyt nh nu bng iu khin c th thay i gi tr tham s. kha ny khng gii hn thay i tham s ca macro. kha ny khng gii hn thay i tham s u vo c vit bi fieldbus. gi tr ny c th thay i ch nu nhp ng m vt qua. S l thng s 1603 PASS CODE.
0 = LOCKED bn khng th s dng bng iu khin thay i gi tr tham s. cc kha c th c m bng cch nhp m thng qua hp l tham s 1603. 1 = OPEN bn c th s dng bng iu khin thay i gi tr tham s. 2 = NOT SAVED bn c th s dng bng iu khin thay i gi tr tham s, nhng chng khng c lu tr trong b nh lu di. thit lp thng s 1607 PARAM SAVE n 1 (SAVE) lu tr cc gi tr thng s thay i vo b nh. 1603 PASS CODE Nhp chnh xc m vt qua cho php bn thay i tham s kha . xem thng s 1602 trn. m s 358 cho php bn thay i gi tr ca tham s 1602 . mc ny chuyn ngc n 0 t ng . 1604 FAULT RESET SEL Chn ngun tn hiu reset li. tn hiu reset bin tn sau mt li ngt nu nguyn nhn gy ra li khng cn tn ti . 0 = KEYPAD xc nh bng iu khin nh ngun reset li li. reset lun lun c th vi bng iu khin. 1 = DI1 xc nh u vo s DI1 nh ngun reset li li. kch hot u vo s resets li bin tn. 26 = DI2DI6 xc nh u vo s DI2DI6 nh ngun reset li li. xem DI1 trn. 7 = START/STOP xc nh lnh dng nh ngun reset li li. khng s dng ty chn ny khi truyn thng fielbus cung cp khi ng, dng v lnh hng. 8 = COMM xc nh fieldbus nh ngun reset li li. lnh Word c cung cp thng qua truyn thng fieldbus . bit 4 ca Command Word 1 (thng s 0301) reset bin tn. -1 = DI1(INV) xc nh ngc u vo s DI1 nh ngun reset li li. kh kch hot u vo s reset bin tn. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh ngun reset li li. xem DI1(INV) trn.

Parameters

122

ACS550 Users Manual

Code Description 1605 USER PAR SET CHG

Xc nh kim sot thay i tham s ngi dng thit lp. xem tham s 9902 APPLIC MACRO.
bin tn phi dng li ngi dng thay i thng s thit lp. trong mt thay i, bin tn s khng khi ng. Ch : lun lun lu thng s ngi ng thit lp sau khi thay i bt k thng s ci t , hoc thc hin nhn dng ng c. bt k khi no ngun in l chu k, hoc tham s 9902 APPLIC MACRO thay i, bin tn ti cc ci t mi nht c lu, bt k thay i khng c lu vo tham s ngi dng thit lp b mt. Ch : gi tr ca thng s ny (1605) khng bao gm User Parameter Sets, v n khng thay i nu User Parameter Sets thay i. Ch : bn c th s dng relay u ra gim st vic chn ca User Parameter Set 2. xem tham s 1401. 0 = NOT SEL xc nh bng iu khin (s dng tham s 9902) nh kim sot cho thay i User Parameter Sets. 1 = DI1 xc nh u vo s DI1 nh mt kim sot cho thay i User Parameter Sets. bin tn ti User Parameter Set 1 trn cnh xung ca u vo s. bin tn ti User Parameter Set 2 trn cnh ln ca u vo s. User Parameter Set thay i ch khi bin tn dng. 26 = DI2DI6 xc nh u vo s DI2DI6 nh mt kim sot cho thay i User Parameter Sets. xem DI1 trn. -1 = DI1(INV) xc nh ngc u vo s DI1 nh mt kim sot cho thay i User Parameter Sets. bin tn ti User Parameter Set 1 trn cnh ln ca u vo s. bin tn ti User Parameter Set 2 trn cnh xung ca u vo s. User Parameter Set thay i ch khi bin tn dng. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh mt kim sot cho thay i User Parameter Sets. xem DI1(INV) trn . 1606 LOCAL LOCK Xc nh kim sot cho s dng ca ch LOC. Ch LOC cho php kim sot bin tn t bng iu khin. khi LOCAL LOCK hot ng, bng iu khin khng th thay i n ch LOC. 0 = NOT SEL v hiu ha cc kha. Bng iu khin c th chn LOC v kim soat bin tn. 1 = DI1 xc nh u vo s DI1 nh mt kim sot cho thit lp kha cc b . kch hot u vo s kha ra kim sot cc b. kh kch hot u vo s cho php chn LOC. 26 = DI2DI6 xc nh u vo s DI2DI6 nh mt kim sot cho thit lp kha cc b. xem DI1 trn. 7 = ON t kha. Bng iu khin khng th chn LOC v khng th kim sot bin tn. 8 = COMM xc nh bit 14 ca Command Word 1 nh mt kim sot cho thit lp kha cc b . Command Word c cung cp thng qua giao tip fieldbus. Command Word l 0301. -1 = DI1(INV) xc nh ngc u vo s DI1 nh mt kim sot cho thit lp kha cc b. kh kch hot u vo s kha ra kim sot cc b. kch hot u vo s cho php chn LOC. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot cho thit lp kha cc b. xem DI1(INV) trn. 1607 PARAM SAVE Lu tt c thay i cc thng s vo b nh vnh vin. thay i thng s thng qua fieldbus khng t ng lu vo b nh vnh vin. lu, bn phi s dng tham s ny. nu 1602 PARAMETER LOCK = 2 (NOT SAVED), cc thng s thay i t bng iu khin khng c lu. lu, bn phi s dng tham s ny. nu 1602 PARAMETER LOCK = 1 (OPEN), thng s thay i t bng iu khin c lu ngay vo b nh vnh vin. 0 = DONE t ng thay i thng s khi tt c thng s c lu. 1 = SAVE lu thay i cc thng s vo b nh vnh vin.

Parameters

ACS550 Users Manual

123

Code 1608

Description START ENABLE 1 Chn ngun ca tn hiu cho php khi ng 1. Ch : chc nng cho php khi ng khc vi chc nng cho php chy . 0 = NOT SEL cho php bin tn khi ng m khng c mt tn hiu cho php khi ng bn ngoi . 1 = DI1 xc nh u vo s DI1 nh tn hiu cho php khi ng 1. u vo s ny phi c kch hot cho tn hiu cho php khi ng 1. nu in p thp v kh kch hot u vo s ny, bin tn s dng theo qun tnh v hin th bo ng 2021 trn mng hnh hin th. Bin tn s khng khi ng n khi tn hiu cho php khi ng 1 tip tc. 26 = DI2DI6 xc nh u vo s DI2DI6 nh tn hiu cho php khi ng 1. xem DI1 trn. 7 = COMM Assigns the fieldbus Command Word nh ngun cho tn hiu cho php khi ng 1. Bit 2 ca Command word 2 (thng s 0302) kch hot tn hiu cho php khi ng 1. xem hng dn s dng fieldbus c hng dn chi tit . -1 = DI1(INV) xc nh ngc u vo s DI1 nh tn hiu cho php khi ng 1 . -2-6 = DI2 (INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh tn hiu cho php khi ng 1 . xem DI1 (INV) trn. Drive started START/STOP COMMAND (Group 10) START ENABLE SIGNAL (Parameters 1608 & 1609) Relay de-energized Relay energized STARTED RELAY STATUS (Group 14) Damper open Damper closed Damper opening time Damper closed DAMPER Damper closing time STATUS

RUN ENABLE SIGNAL from the damper end switch when the damper is fully opened. (Parameter 1601)

MOTOR STATUS Acceleration time (Par 2202) Drive coasts to stop

Parameters

124

ACS550 Users Manual

Code 1609

Description START ENABLE 2 Ch ngun ca tn hiu cho php khi ng 2. Ch : chc nng cho php khi ng khc vi chc nng cho php chy. 0 = NOT SEL cho php bin tn khi ng m khng c mt tn hiu cho php khi ng bn ngoi. 1 = DI1 xc nh u vo s DI1 nh tn hiu cho php khi ng 2 . u vo s ny phi c kch hot cho tn hiu cho php khi ng 2. nu in p thp v kh kch hot u vo sny, bin tn s dng theo qun tnh v hin th bo ng 2022 trn mng hnh hin th. Bin tn s khng khi ng n khi tn hiu cho php khi ng 2 tip tc. 26 = DI2DI6 xc nh u vo s DI2DI6 nh tn hiu cho php khi ng 2. xem DI1 trn. 7 = COMM Assigns the fieldbus Command Word nh ngun cho tn hiu cho php khi ng 2. Bit 3 ca Command word 2 (thng s 0302) kch hot tn hiu cho php khi ng 2 . xem hng dn s dng fieldbus c hng dn chi tit. -1 = DI1(INV) xc nh ngc u vo s DI1 nh tn hiu cho php khi ng 2. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh tn hiu cho php khi ng 2. xem DI1 (INV) trn.

1610

DISPLAY ALARMS iu khin kh nng hin th ca cc bo ng sao y : 2001, bo ng qu dng 2002, bo ng qu p 2003, bo ng thp p 2009, bo ng qu nhit thit b. bit thm thng tin, xem phn Alarm listing trn trang 250. 0 = NO cc bo ng trn l b chn. 1 = YES tt c cc bo ng trn l c kch hot .

1611

PARAMETER VIEW Chn ch xem thng s, tc l thng s c hin th. Ch : thng s ny ch c hin th khi n c kch hot bng thit b FlashDrop. FlashDrop c thit k cho vic sao chp thng s nhanh chng khi khng cp in cho bin tn. n cho php d dng sa i danh sch tham s, e.g. chn thng s c n. bit thm thng tin, xem MFDT-01 FlashDrop Users Manual [3AFE68591074 (ting anh)]. FlashDrop gi tr tham s c kch hot bng cch t tham s 9902 n 31 (LOAD FD SET). 0 = DEFAULT danh sch y tham s di v ngn c hin th. 1 = FLASHDROP FlashDrop danh sch tham s c hin th. Khng bao gm danh sch tham s ngn. tham s c n bng thit b FlashDrop khng nhn thy c.

Parameters

ACS550 Users Manual

125

nhm 20: LIMITS Nhm ny xc nh gii hn nh nht v ln nht theo di iu khin ng c tc , tn s, dng in, momen xon, v.v.
Code Description 2001 MINIMUM SPEED Xc nh tc nh nht cho php (rpm). mt s dng (hoc khng) gi tr tc nh nht xc nh hai dy, mt dng v mt m . mt gi tr tc m xc nh mt dy tc . xem hnh. Speed P 2002 Speed range allowed 0 P 2001 2001 gi tr l < 0

Time

2002

MAXIMUM SPEED Xc nh tc ln nht cho php (rpm).

Speed P 2002

2001 gi tr l > 0

Speed range allowed P 2001 0 -(P 2001) Speed range allowed -(P 2002) 2003 2005 MAX CURRENT Xc nh dng in u ra ln nht (A) cung cp bi bin tn n ng c. OVERVOLT CTRL Thit lp iu khin qu in p DC on hoc off. phanh nhanh ca mt qun tnh ti cao gy ra in p DC bus tng ln n gii hn kim sot qu p. ngn chn in p DC t vt qu gii hn ngt, b iu khin qu in p t ng lm gim momen xon phanh bng cch tng tn s u ra. 0 = DISABLE v hiu ha b iu khin. 1 = ENABLE cho php b iu khin Ch : nu thng in hoc thng in tr c kt ni vi bin tn, gi tr tham s ny phi c t n 0 (DISABLE) m bo hot ng tt ca thng in. 2006 UNDERVOLT CTRL Thit lp iu khin thp in p DC on hoc off. khi on : nu in p DC bus thp mt in p u vo, b iu khin thp p gim tc ng c gi in p DC bus trn gii hn thp . khi ng c gim tc , qun tnh ti gy ra ti sinh vo bin tn, gi DC bus thay i v ngn cn ngt thp p. b iu khin thp p trung gian DC lm tng tn tht ngun in thng qua h thng vi mt qun tnh cao, chn hn nh my li tm hoc mt qut. 0 = DISABLE v hiu ha iu khin. 1 = ENABLE(TIME) cho php iu khin vi 500 ms gii hn thi gian cho hot ng. 2 = ENABLE cho php iu khin vi gii hn thi gian hot ng ln nht cho hot ng . Time

Parameters

126

ACS550 Users Manual

Code Description 2007 MINIMUM FREQ Xc nh gii hn nh nht cho u ra tn s bin tn gi tr tn s nh nht dng hoc khng xc nh hai dy mt dng v mt m. mt gi tr nh nht m xc nh mt dy tc . Xem hnh. Ch : gi MINIMUM FREQ v MAXIMUM FREQ. 2008 MAXIMUM FREQ Xc nh gii hn ln nht cho u ra tn s bin tn. Freq P 2008 Frequency range allowed P 2007 0 -(P 2007) Frequency range allowed -(P 2008) 2013 MIN TORQUE SEL Xc nh kim xot ca chn gia hai gii hn momen xon nh nht (2015 MIN TORQUE 1 v 2016 MIN TORQUE 2). 0 = MIN TORQUE 1 chn 2015 MIN TORQUE 1 l gii hn s dng nh nht. 1 = DI1 xc nh u vo s DI1 nh kim sot chn gii hn s dng nh nht. kch hot u vo s chn gi tr MIN TORQUE 2. kh kch hot u vo s chn gi tr MIN TORQUE 1 . 26 = DI2DI6 xc nh u vo s DI2DI6 nh kim sot chn gii hn s dng nh nht. xem DI1 trn. 7 = COMM xc nh bit 15 ca Command Word 1 nh kim sot cho chn gii hn s dng nh nht. Command Word c cung cp thng qua giao tip fieldbus . Command Word l tham s 0301. -1 = DI1(INV) xc nh ngc u vo s DI1 nh kim sot cho chn gii hn s dng nh nht. kch hot u vo s chn gi tr MIN TORQUE 1 . kh kch hot u vo s chn gi tr MIN TORQUE 2. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot cho chn gii hn s dng nh nht . xem DI1(INV) trn. 2014 MAX TORQUE SEL Xc nh kim xot ca chn gia hai gii hn momen xon ln nht (2017 MAX TORQUE 1 v 2018 MAX TORQUE 2). 0 = MAX TORQUE 1 chn 2017 MAX TORQUE 1 l gii hn s dng ln nht. 1 = DI1 xc nh u vo KTS DI1 nh kim sot chn gii hn s dng ln nht. kch hot u vo KTS chn gi tr MAX TORQUE 2. kh kch hot u vo KTS chn gi tr MAX TORQUE 1. 26 = DI2DI6 xc nh u vo KTS DI2DI6 nh kim sot chn gii hn s dng ln nht. xem DI1 trn. 7 = COMM xc nh bit 15 ca Command Word 1 nh kim sot cho chn gii hn s dng ln nht.. Command Word c cung cp thng qua giao tip fieldbus. kh kch hot u vo KTS chn gi tr 0301. -1 = DI1(INV) xc nh ngc u vo KTS DI1 nh kim sot cho chn gii hn s dng ln nht. kch hot u vo KTS chn gi tr MAX TORQUE 1 . kh kch hot u vo KTS chn gi tr MAX TORQUE 2 . -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo KTS DI2DI6 nh kim sot cho chn gii hn s dng ln nht . xem DI1(INV) trn. 2015 2016 MIN TORQUE 1 Thit lp gii hn nh nht u tin (%). Gi tr l phn trm ca momen xon danh nh ng c. MIN TORQUE 2 Thit lp gii hn nh nht th hai (%). Gi tr l phn trm ca momen xon danh nh ng c. Time 2007 value is > 0 Freq P 2008 Frequency range allowed 0 P 2007 2007 value is < 0

Time

Parameters

ACS550 Users Manual

127

Code Description 2017 2018 MAX TORQUE 1 Thit lp gii hn ln nht u tin (%). Gi tr l phn trm ca momen xon danh nh ng c. MAX TORQUE 2 Thit lp gii hn ln nht th hai (%). Gi tr l phn trm ca momen xon danh nh ng c.

Parameters

128

ACS550 Users Manual

nhm 21: START/STOP Nhm ny xc nh lm th no khi ng v dng ng c. ACS550 h tr mt s ch khi ng v dng .


Code Description 2101 START FUNCTION Chn phng php khi ng ng c. Cc ty chn ph thuc vo gi tr ca tham s 9904 MOTOR CTRL MODE. 1 = AUTO chn ch t ng khi ng. ch kim sot Vector: ti u trong nhiu trng hp. bin tn t ng chn tn s u ra chnh xc bt u quay ng c. ch SCALAR:FREQ: khi ng ngay lp tc t tn s khng . 2 = DC MAGN chn ch khi ng t ha DC Ch : ch khi ng t ha DC khng th khi ng khi ng c ang quay . Ch : bin tn khi ng khi thi gian thit lp t ha (tham s 2103 DC MAGN TIME) thng qua, ngay c khi t ha ng c khng hon thnh . ch kim sot Vector: t ha ng c trong thi gian xc nh bi tham s 2103 DC MAGN TIME bng cch s dng dng DC. kim sot thng thng c cho php sau khi thi gian t ha. La chn ny m bo momen xon lun lun cao nht c th lun lun gy ra . ch SCALAR:FREQ: t ha ng c trong thi gian xc nh bi tham s 2103 DC MAGN TIME s dng dng in DC. kim sot thng thng c cho php sau khi thi gian t ha. 3 = SCALAR FLYST chn flying ch khi ng . ch kim sot Vector: khng p dng. ch SCALAR:FREQ: bin tn t ng chn chnh xc tn s u ra khi ng quay ng c c ch nu ng c ang quay v nu bin tn khi ng tt tn s hin ti. 4 = TORQ BOOST chn ch t ng tng cng momen xon ( ch ch SCALAR:FREQ). c th cn thit trong bin tn vi momen xon khi ng cao . momen xon tng chi p dng ti khi ng, kt thc khi tn s u ra vt qu 20 Hz hoc khi tn s u ra bng tham chiu. trong bt u t ha ng c thi gian xc nh bi tham s 2103 DC MAGN TIME s dng dng DC . xem tham s 2110 TORQ BOOST CURR. 5 = FLY + BOOST chn c hai khi ng flying v ch tng cng momen xon (ch ch SCALAR:FREQ). Flying start thc hin ln u v ng c t ha. Nu tc tm thy l khng, tng momen xon c thc hin . 8 = RAMP khi ng ngay lp tc t tn s khng. 2102 STOP FUNCTION Chn phng php dng ng c. 1 = COAST chn ct ngun cung cp ca ng c nh phng php dng. ng c quay theo qun tnh n dng. 2 = RAMP chn s dng dc gim tc. dc gim tc xc nh bi tham s 2203 DECELER TIME 1 hoc 2206 DECELER TIME 2 (ty theo hot ng ). 2103 DC MAGN TIME Xc nh thi gian t ha cho ch khi ng DC Magnetizing. s dng tham s 2101 chn ch khi ng. sau lnh khi ng bin tn t ha ng c trong thi gian quy nh v sau khi ng ng c. t thi gian t ha di cho php t ha y ng c. Thi gian qu di lm nng ng c qu mc. 2104 DC HOLD CTL Motor speed chn dng DC c s dng cho phanh hoc DC Hold . 0 = NOT SEL v hiu ha dng in DC hot ng. 1 = DC HOLD cho php chc nng DC Hold . xem s . yu cu tham s 9904 MOTOR CTRL MODE = 1 (VECTOR:SPEED) dng to dng in hnh sin v tng DC vo ng c khi c hai tham chiu v gim tc ng c di gi tr ca tham s Ref 2105. khi tham chiu tng ln trn mc ca tham s 2105 bin tn gi DC hold hot ng bnh thng. speed 2 = DC BRAKING cho php DC Injection Braking sau khi dng . nu tham s 2102 STOP FUNCTION l 1 (COAST), phanh c p dng sau khi ng g b. nu tham s 2102 STOP FUNCTION l 2 (RAMP), phanh c p dng sau dc. DC hold

Parameters

ACS550 Users Manual

129

Code 2105 2106 2107 2108

Description DC HOLD SPEED t tc cho DC Hold. Yu cu tham s 2104 DC HOLD CTL = 1 (DC HOLD). DC CURR REF Xc nh kim sot tham chiu dng in DC nh phn trm ca tham s 9906 MOTOR NOM CURR. DC BRAKE TIME Xc nh thi gian phanh DC sau khi iu bin dng li, nu tham s 2104 l 2 (DC BRAKING). START INHIBIT Thit lp chc nng Start inhibit on hoc off. Chc nng Start inhibit b qua mt lnh khi ng trong bt k tnh hung sau y (mt lnh mi l bt but): mt li l reset. Run Enable (tham s 1601) kch hot trong khi lnh khi ng c kch hot. thay i ch t cc b sang t xa. kim sot chuyn i t EXT1 n EXT2. kim sot chuyn i t EXT2 n EXT1. 0 = OFF v hiu ha chc nng Start inhibit . 1 = ON cho php chc nng the Start inhibit .

2109

EMERG STOP SEL Xc nh kim sot ca lnh dng khn cp. khi c kch hot : dng khn cp gim tc ng c bng cch s dng dc dng khn cp (tham s 2208 EMERG DEC TIME). cn phi c lnh dng bn ngoi v loi b lnh dng khn cp trc khi bin tn c th khi ng li . 0 = NOT SEL v hiu ha chc nng dng khn cp thng qua cc u vo k thut s . 1 = DI1 xc nh u vo s DI1 nh kim sot cho lnh dng khn cp. kch hot u vo s mt lnh dng khn cp. kh kch hot u vo s loi b mt lnh dng khn cp. 26 = DI2DI6 xc nh u vo s DI2DI6 nh kim sot cho lnh dng khn cp. xem DI1 trn. -1 = DI1(INV) xc nh ngc u vo s DI1 nh kim sot cho lnh dng khn cp. kch hot u vo s mt lnh dng khn cp. kh kch hot u vo s loi b mt lnh dng khn cp. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot cho lnh dng khn cp. xem DI1(INV) trn.

2110

TORQ BOOST CURR Xc nh cung cp dng in ln nht trong thi gian tng momen xon. xem tham s 2101 START FUNCTION.

Parameters

130

ACS550 Users Manual

Code Description 2112 ZERO SPEED DELAY Xc nh tr cho chc nng Zero Speed Delay . nu gi tr tham s t n khng, chc nng Zero Speed Delay b v hiu ha. Chc nng ny rt hu ch trong cc ng dng ni mt khi ng trn tru v nhanh chng l cn thit. trong thi gian chm tr bin tn bit chnh xc v tr rotor No Zero Speed Delay Speed Speed controller switched off: Motor coasts to stop. With Zero Speed Delay Speed Speed controller remains live. Motor is decelerated to true 0 speed.

Zero Speed t

Zero Speed t

Delay Tc tr khng c th c s dng e.g. vi chc nng chy nhp hoc phanh c kh. No Zero Speed Delay Bin tn nhn c lnh dng v gim tc cng mt dc. khi tc thc t ng c gim xung di mt gii hn ni b (gi Zero Speed), b iu khin tc tc off. iu bin bin tn dng li theo qun tnh ng c n dng. With Zero Speed Delay Bin tn nhn c lnh dng v gim tc cng mt dc. khi tc thc t ng c gim xung di mt gii hn ni b (gi Zero Speed), tc tr khng hot ng. trong thi gian tr chc nng gi cho b iu khin tc sng: iu bin bin tn, ng c c t ha v bin tn sn sng cho khi ng li nhanh chng. Ch : tham s 2102 STOP FUNCTION must be 2 = RAMP cho tc khng n hot ng. 0.0 = NOT SEL v hiu ha chc nng Zero Speed Delay . 2113 START DELAY Xc nh khi ng tr. Sau khi iu kin cho khi ng c hon thnh, bin tn i cho n khi tr hon tri qua v sau khi ng dng c. Khi ng tr c th s dng vi tt c cc ch khi ng. nu START DELAY = zero, chm tr b v hiu ha. trong thi gian khi ng tr, bo ng 2028 START DELAY c hin th.

Parameters

ACS550 Users Manual

131

nhm 22: ACCEL/DECEL Nhm ny xc nh dc kim sot t l ca tng tc v gim tc . Bn xc nh cc cp dc, mt cho tng tc v mt cho gim tc. Bn c th xc nh hai cp dc v s dng u vo s chn mt trong hai cp khc nhau .
Code 2201 Description ACC/DEC 1/2 SEL Xc nh kim sot chn dc tng tc /gim tc. dc c xc nh trong cp, mi cp cho tng tc v gim tc. xem di y cho xc nh dc tham s. 0 = NOT SEL v hiu ha chn, cp c u tin c s dng. 1 = DI1 xc nh u vo KTS DI1 nh kim sot chn cp dc. kch hot u vo KTS chn cp dc 2. kh kch hot u vo KTS chn cp dc 1. 26 = DI2DI6 xc nh u vo KTS DI2DI6 nh kim sot chn cp dc. xem DI1 trn. 7 = COMM xc nh bit 10 ca Command Word 1 nh kim sot chn cp dc. Command Word c cung cp thng giao tip fieldbus . Command Word l tham s 0301. -1 = DI1(INV) xc nh ngc u vo KTS DI1 nh kim sot chn cp dc. kh kch hot u vo KTS chn cp dc 2 kch hot u vo KTS chn cp dc 1. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo KTS DI2DI6 nh kim sot chn cp dc. xem DI1(INV) trn . 2202 ACCELER TIME 1 Thit lp thi gian tng tc t khng n tn s ln nht cho cp dc mt 1. xem hnh. thi gian tng tc thc t nh xc nh trn 2204 RAMP SHAPE 1. xem 2008 MAXIMUM FREQ. 2203 DECELER TIME 1 Thit lp thi gian gim tc t tn s ln nht n khng cho cp dc mt 1. thi gian gim tc thc t nh xc nh trn 2204 RAMP SHAPE 1. xem 2008 MAXIMUM FREQ. 2204 RAMP SHAPE 1 Chn hnh dng ca dc tng tc /gim tc cho cp dc mt 1. xem hnh trong B . hnh dng c xc nh nh dc, tr thm thi gian quy nh y t c tn s ti a. Thi gian di cung cp mt s chuyn tip mm hn cui mi dc hnh dng tr thnh ng cong s- . nguyn tc nh: 1/5 l h thc ph hp gia dng dc thi gian v dc thi gian khi ng. 0.0 = LINEAR ch nh tuyn dc tng tc /gim tc cho cp dc 1. 0.11000.0 = S-CURVE ch nh ng cong s-dc tng tc/gim tc cho cp dc 1. 2205 ACCELER TIME 2 Thit lp thi gian tng tc t khng n tn s ln nht cho cp dc 2. xem 2202 ACCELER TIME 1. c s dng cng nh thi gian tng tc chy nhp. xem 1004 JOGGING SEL. 2206 DECELER TIME 2 Thit lp thi gian gim tc t tn s ln nht n khng cho cp dc 2. xem 2203 DECELER TIME 1. c s dng cng nh thi gian gim tc chy nhp. xem 1004 JOGGING SEL. 2207 RAMP SHAPE 2 Chn hnh dng ca dc tng tc /gim tc cho cp dc 2. xem 2204 RAMP SHAPE 1.
MAX FREQ

Linear

B (=0) T
MAX FREQ

S-curve

B A A = 2202 ACCELER TIME 1 B = 2204 RAMP SHAPE 1

Parameters

132

ACS550 Users Manual

Code Description 2208 EMERG DEC TIME Thit lp thi gian gim tc t tn s ln nht n khng cho dng khn cp. xem tham s 2109 EMERG STOP SEL. dc l tuyn tnh . 2209 RAMP INPUT 0 Xc nh kim sot cho buc dc u vo n 0. 0 = NOT SEL khng chn. 1 = DI1 xc nh u vo s DI1 nh kim sot cho buc dc u vo n 0. kch hot u vo s buc dc n khng 0. dc u ra s l dc n 0 ph hp vi dng in s dng dc thi gian, sau n s dng li n 0. kh kch hot u vo s: tip tc hot ng dc bnh thng . 26 = DI2DI6 xc nh u vo s DI2DI6 nh kim sot cho buc dc u vo n 0. xem DI1 trn. 7 = COMM xc nh bit 13 ca Command Word 1 nh kim sot cho buc dc u vo n 0. Command Word c cung cp thng qua giao tip fieldbus . Command Word l tham s 0301. -1 = DI1(INV) xc nh ngc u vo s DI1 nh kim sot cho buc dc u vo n 0. kh kch hot u vo s buc dc n khng 0. kch hot u vo KTS: tip tc hot ng dc bnh thng. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot cho buc chc nng dc pht in u vo n 0. xem DI1(INV) trn.

Parameters

ACS550 Users Manual

133

nhm 23: SPEED CONTROL Nhm ny xc nh s dng bin cho hot ng kim sot tc .
Code 2301 Description PROP GAIN Thit lp li cho iu khin tc . gi tr ln hn c th gy ra dao ng tc . cc con s cho thy iu khin tc u ra sau mt bc li (li vn khng i). Ch : c th s dng thm s 2305 AUTOTUNE RUN t ng thit lp theo t l li . Gain = Kp = 1 TI = Integration time = 0 TD= Derivation time = 0 Error value Controller output e = Error value t Controller output Gain = Kp = 1 TI = Integration time > 0 TD= Derivation time = 0

Controller output = Kp e

2302

INTEGRATION TIME Thit lp thi gian tch hp cho b iu khin tc . thi gian tch hp xc nh mc tc m b iu khin u ra thay i cho mt gi tr li khng i. ngn mch thi gian tch hp lm kim sot khng bn . kim sot tr nn khng n nh nu thi gian tch hp qu ngn cc con s cho thy iu khin tc u ra sau mt bc li (li vn khng i). Ch : bn c th s dng tham s 2305 AUTOTUNE t ng thit lp theo thi gian tch hp .

Kp e

Kp e

e = Error value t TI

2303

DERIVATION TIME Thit lp thi gian dn sut cho iu khin tc . hot ng dn sut lm cho kim sot p ng nhiu hn thay i gi tr li. thi gian dn sut qu di , nhiu hn u ra iu khin tc thc y trong thi gian thay i . nu thi gian dn sut t n khng , b iu khin hot ng nh b iu khin PI, nu khng nh b diu khin PID.

Hnh di y cho thy iu khin tc u ra sau mt bc li khi li ny vn khng i.


%

Kp TD

Ts Kp e

Controller output

Error value

Gain = Kp = 1 TI = thi gian tch hp > 0 TD= thi gian dn sut > 0 Ts= khong thi gian lp li = 2 ms = gi tr li thay i gia hai khong

Kp e

e = Error value t TI

Parameters

134

ACS550 Users Manual

Code Description 2304 ACC COMPENSATION Thit lp thi gian dn sut cho b gia tc . thm mt dn sut ca tham chiu n u ra ca b iu khin tc cho qun tnh trong thi gian tng tc. 2303 DERIVATION TIME m t nguyn tc ca hot ng dn sut . nguyn tc nh: thit lp tham s gia 50 v 100% ca tng hng s thi gian c hc cho ng c v my iu khin. cc con s cho thy tc phn ng khi mt qun tnh ti cao l tng tc dc theo dc. * No acceleration compensation % Acceleration compensation %

Speed reference Actual speed t *ch : bn c th s dng tham s 2305 AUTOTUNE RUN t ng thit lp b thi gian khi ng. 2305 AUTOTUNE RUN T ng khi ng iu chnh b iu khin tc . 0 = OFF v hiu ha qu trnh Autotune. (khng th v hiu ha hot ng ca thit lp Autotune.) 1 = ON kch hot b iu khin tc autotuning. T ng phc hi n OFF. Phng php: Ch : ng c phi c kt ni vi ti. chy ng c tc khng i ca 20 n 40% ca t l tc . thay i t ng iu chnh tham s 2305 n ON. Bin tn: tng tc ng c. tnh gi tr t c gi tr, thi gian tch hp v b tng tc. thay i tham s 2301, 2302 v 2304 n cc gi tr ny. Reset 2305 n OFF. t

Parameters

ACS550 Users Manual

135

nhm 24: TORQUE CONTROL Nhm ny xc nh s dng cc bin cho kim sot hot ng ca momen xon.
Code 2401 Description TORQ RAMP UP Xc nh dc thi gian ln ca momen xon tham chiu thi gian nh nht tham chiu tng t khng n momen xon danh nh ng c. 2402 TORQ RAMP DOWN Xc nh dc thi gian xung ca momen xon tham chiu thi gian nh nht tham chiu gim t momen xon danh nh n khng .

Parameters

136

ACS550 Users Manual

nhm 25: CRITICAL SPEEDS Nhm ny xc nh ti a ba tc quan trng hoc phm vi tc trnh n, v d, cng hng c kh tc nht nh .
Code Description 2501 CRIT SPEED SEL Thit lp chc nng tc quan trng on hoc off. chc nng tc quan trng trnh phm vi tc c th. 52 0 = OFF v hiu ha chc nng tc quan trng. 1 = ON cho php chc nng tc quan trng. 46 V d : trnh tc m ti h thng qut b rung: xc nh phm vi tc . Gi s chng c tm thy 23 : 1823 Hz v 4652 Hz. 18 Set 2501 CRIT SPEED SEL = 1. Set 2502 CRIT SPEED 1 LO = 18 Hz. Set 2503 CRIT SPEED 1 HI = 23 Hz. Set 2504 CRIT SPEED 2 LO = 46 Hz. Set 2505 CRIT SPEED 2 HI = 52 Hz. 2502 CRIT SPEED 1 LO Thit lp gii hn nh nht cho phm vi tc quan trng 1. gi tr phi nh hn hoc bng 2503 CRIT SPEED 1 HI. n v l rpm, tr khi n v 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ), sau l Hz. 2503 CRIT SPEED 1 HI Thit lp gii hn ln nht cho phm vi tc quan trng 1. gi tr phi ln hn hoc bng 2502 CRIT SPEED 1 LO. n v l rpm, tr khi n v 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ), sau l Hz. 2504 CRIT SPEED 2 LO Thit lp gii hn nh nht cho phm vi tc quan trng 2. xem tham s 2502. 2505 CRIT SPEED 2 HI Thit lp gii hn ln nht cho phm vi tc quan trng 2. xem tham s 2503. 2506 CRIT SPEED 3 LO Thit lp gii hn nh nht cho phm vi tc quan trng 3. xem tham s 2502. 2507 CRIT SPEED 3 HI Thit lp gii hn ln nht cho phm vi tc quan trng 3. xem tham s 2503. foutput

fREF (Hz) f1L f1H 18 23 f2L f2H 46 52

Parameters

ACS550 Users Manual

137

nhm 26: MOTOR CONTROL Nhm ny xc nh bin s dng cho kim sot ng c .
Code Description 2601 FLUX OPT ENABLE

Thay i ln ca thng lng ty thuc vo ti thc t. Ti u ha thng lng c th gim tiu th nng lng tng v ting n, v n s c kch hot cho cc bin tn thng hot ng di ti danh ngha
0 = OFF v hiu ha tnh nng ny. 1 = ON cho php tnh nng ny . 2602 FLUX BRAKING Cung cp gim tc nhanh hn bng cch tng mc t ha trong ng c khi cn thit , thay v gii hn dc gim tc . bng cch tng thng lng ng c , nng lng ca h thng my c thay i thnh nng lng nhit trong ng c yu cu tham s 9904 MOTOR CTRL MODE = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ). 0 = OFF v hiu ha tnh nng ny. 1 = ON cho php tnh nng ny. Braking torque (%) 120% 80 40 2 0 120% 80 40 0 5 5 2 4 10 3 20 30 40 50 f (Hz) 5 Rated motor power 1 2.2 kW Without flux braking 2 15 kW 3 37 kW 4 75 kW 1 5 250 kW 3 4 5 10 20 30 40 50 f (Hz)

With flux braking

2603

IR COMP VOLT Thit lp b IR in p s dng cho 0 Hz. yu cu tham s 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ). gi b IR cng thp cng tt trnh b qu nng . chun gi tr b IR l: 380480 V drives PN (kW) 3 IR comp (V) 18

B IR khi cho php,b IR cung cp tng in p b sung ng c tc thp. s dng b IR V d , trong ng dng i hi momen xon ph hy cao . Motor voltage A

7.5 15

15 12

37 8

132 3 P 2603

A = IR compensated B = No compensation f (Hz)

2604

IR COMP FREQ Thit lp tn s m b IR l 0 V (trong % ca tn s ng c). B P 2604

2605

U/F RATIO Chn hnh thc cho U/f (in p n tn s) t l di im trng suy yu. 1 = LINEAR u tin cho cc ng dng momen xon khng i. 2 = SQUARED u tin cho cc bm li tm v ng dng qut. (Square l im lng hn cho hu ht cc tn s hot ng.)

Parameters

138

ACS550 Users Manual

Code Description 2606 SWITCHING FREQ Thit lp tn s chuyn i cho bin tn. xem thm tham s 2607 SWITCH FREQ CTRL v phn Switching frequency derating trn trang 262. chuyn i tn s cao hn c ngha l t ting n. 1, 4 v 8 kHz chuyn i tn s c sn cho tt c cc loi, tr ACS550-01-246A-4 ch 1 v 4 kHz l c sn. 12 kHz chuyn i tn s c sn ch khi tham s 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ). 12 kHz chuyn i tn s c sn cho 200 V v 400 V c khung R1R4 (tr loi R4 ACS550-01-087A-4 v ACS550-U1-097A-4) v cho 600 V c khung R2R4. SWITCH FREQ CTRL Tn s chuyn mch c th gim xung nu nhit ni b tng ACS550 trn mt gii hn. xem hnh. Chc nng ny cho php tn s chuyn i cao nht c th c s dng da trn iu kin hot ng. Chuyn i tn s cao hn kt qu l ting n m thanh thp hn . 0 = OFF chc nng b v hiu ha. 1 = ON tn s chuyn i c gii hn theo cc con s . 2608 SLIP COMP RATIO t li cho b trc (trong %). mt ng c lng sc trc di ti. tng tn s nh tng momen xon ng c b cho s trc . yu cu tham s 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ). 0 khng b trc. 1200 tng b trc. 100% ngha l b trc y . 2609 NOISE SMOOTHING fsw limit 12 kHz 8 kHz 4 kHz 80 C 90 C 100 C T R1R4 drives, see par 2606 R5R6 drives, see par 2606 Drive temperature

2607

Tham s ny gii thiu mt thnh phn ngu nhin vo cc tn s chuyn i. Ting n lm Mn phn phi ting n m thanh ng c qua mt lot tn s thay v mt tn s duy nht dn n cng ting n thp . cc thnh phn ngu nhin c trung bnh 0 Hz. N thm vo tn s chuyn mch c thit lp bi tham s 2606 SWITCHING FREQ. tham s ny khng c tc dng nu tham s 2606 = 12 kHz. 0 = v hiu ha 1 = cho php.
2619 DC STABILIZER Cho php hoc v hiu ha n nh in p DC. n nh DC c s dng trong ch iu khin v hng ngn chn dao ng in p c th trong bin tn DC bus gy ra bi ti ng c hoc mng cung cp yu. trong trng hp bin in p bin tn iu chnh tn s tham chiu n nh in p DC bus v thnh ra dao ng momen xon ti. 0 = DISABLE v hiu ha n nh DC. 1 = ENABLE cho php n nh DC.

Parameters

ACS550 Users Manual

139

nhm 29: MAINTENANCE TRIG Nhm ny cha ng mc s dng v im kch hot. khi s dng t n im t kch hot, mt thng bo hin th trn tn hiu bng iu khin l n lc bo tr.
Code Description 2901 COOLING FAN TRIG Thit lp im kch hot cho b m qut lm mt bin tn. gi tr c so snh vi gi tr tham s 2902 . 0.0 v hiu ha vic kch hot . 2902 COOLING FAN ACT Xc nh gi tr thc t ca b m qut lm mt bin tn. khi tham s 2901 c t gi tr khc khng, b m khi ng. khi gi tr thc t ca b m vt qu gi tr xc nh bi tham s 2901, mt thng bo bo tr c hin th trn bng iu khin 0.0 Reset tham s. 2903 REVOLUTION TRIG Thit lp im kch hot cho b m m vng quay ca ng c. gi tr c so snh vi gi tr tham s 2904 . 0 v hiu ha vic kch hot. 2904 REVOLUTION ACT Xc nh gi tr thc t ca b m m vng quay ca ng c. khi tham s 2903 c t gi tr khc khng, b m khi ng. khi gi tr thc t ca b m vt qu gi tr xc nh bi tham s 2903, mt thng bo bo tr c hin th trn bng iu khin. 0 Resets tham s. 2905 RUN TIME TRIG Thit lp im kch hot cho m thi gian chy ca bin tn. gi tr c so snh vi gi tr tham s 2906 . 0.0 v hiu ha vic kch hot. 2906 RUN TIME ACT Xc nh gi tr thc t ca b m thi gian chy ca bin tn. khi tham s 2905 c t gi tr khc khng, b m khi ng. khi gi tr thc t ca b m vt qu gi tr xc nh bi tham s 2905, mt thng bo bo tr c hin th trn bng iu khin. 0.0 Resets tham s . 2907 USER MWh TRIG Thit lp im kch hot b m cng sut tiu th cng dn ca bin (trong megawatt gi). gi tr c so snh vi gi tr tham s 2908 . 0.0 v hiu ha vic kch hot . 2908 USER MWh ACT Xc nh gi tr thc t ca b m cng sut tiu th cng dn ca bin tn (trong megawatt gi). khi tham s 2907 c t gi tr khc khng, b m khi ng. khi gi tr thc t ca b m vt qu gi tr xc nh bi tham s 2907, mt thng bo bo tr c hin th trn bng iu khin. 0.0 Resets tham s.

Parameters

140

ACS550 Users Manual

nhm 30: FAULT FUNCTIONS Nhm ny xc nh tnh hung m bin tn xc nhn nh l li tim nng v xc nh lm th no bin tn p ng nu li c pht hin .
Code Description 3001 AI<MIN FUNCTION Xc nh bin tn phn ng nu u vo tng t (AI) tn hiu gim xung di mc gii hn li v AI c s dng trong chui tham chiu . 3021 AI1 FAULT LIMIT v 3022 AI2 FAULT LIMIT t gii hn li 0 = NOT SEL khng phn ng . 1 = FAULT hin th mt li (7, AI1 LOSS hoc 8, AI2 LOSS) v bin tn dng theo dc . 2 = CONST SP 7 hin th mt bo ng (2006, AI1 LOSS hoc 2007, AI2 LOSS) v t tc s dng 1208 CONST SPEED 7. 3 = LAST SPEED hin th mt bo ng (2006, AI1 LOSS hoc 2007, AI2 LOSS) v t tc s dng cc cp hot ng mi nht. Gi tr ny l tc trong vng 10 giy cui cng. Cnh bo! Nu bn chn CONST SP 7 or LAST SPEED, chc chn rng cc hot ng l an ton khi tn hiu tng t u vo b mt . 3002 PANEL COMM ERR Xc nh phn ng ca bin tn n giao tip li bng iu khin. 1 = FAULT hin th li (10, PANEL LOSS) v bin tn dng theo dc. 2 = CONST SP 7 hin th mt bo ng (2008, PANEL LOSS) v t tc s dng 1208 CONST SPEED 7. 3 = LAST SPEED hin th mt bo ng (2008, PANEL LOSS) v t tc s dng cc cp hot ng mi nht Gi tr ny l tc trong vng 10 giy cui cng. Cnh bo! Nu bn chn CONST SP 7 hoc LAST SPEED, chc chn rng cc hot ng l an ton khi tn hiu tng t u vo b mt . 3003 EXTERNAL FAULT 1 Xc nh u vo tn hiu li ngoi 1 v phn ng ca bin tn vi mt li ngoi. 0 = NOT SEL tn hiu li ngoi l khng s dng. 1 = DI1 xc nh u vo KTS DI1 nh u vo li ngoi . kch hot u vo KTS ch ra mt li. bin tn hin th mt li (14, EXT FAULT 1) v bin tn dng theo dc . 26 = DI2DI6 xc nh u vo KTS DI2DI6 nh u vo li ngoi. xem DI1 trn. -1 = DI1(INV) xc nh ngc u vo KTS DI1 nh u vo li ngoi. kh kch hot u vo KTS ch ra mt li. bin tn hin th mt li (14, EXT FAULT 1) v bin tn dng theo dc . -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo KTS DI2DI6 nh u vo li ngoi. xem DI1(INV) trn. 3004 EXTERNAL FAULT 2 xc nh u vo tn hiu li ngoi 2 v phn ng ca bin tn vi mt li ngoi. xem tham s 3003 trn. 3005 MOT THERM PROT Xc nh bin tn phn ng n ng c qu nng. 0 = NOT SEL khng phn ng v/hoc bo v nhit khng c thit lp. 1 = FAULT khi tnh ton nhit ng c vt qu 90 C, hin th bo ng (2010, MOTOR TEMP). khi tnh ton nhit ng c vt qu 110 C, hin th li (9, MOT OVERTEMP) v bin tn dng theo qun tnh . 2 = ALARM khi tnh ton nhit ng c vt qu 90 C, hin th bo ng (2010, MOTOR TEMP). 3006 MOT THERM TIME Ti ng c Thit lp thi gian nhit ng c khng i cho cc m hnh nhit ng c . y l thi gian cn thit cho ng c t 63% ca nhit cui cng c ti trng n nh . Temp. rise bo v nhit theo yu cu UL cho NEMA 100% Loi ng c, s dng cc nguyn tc nh: MOTOR THERM TIME bng 63% 35 ln t6, ni t6 (trong vi giy) l quy nh ca nh sn xut ng c nh thi gian ng c c th hot ng an ton su ln dng in cao nht ca n . thi gian nhit cho mt ng cong Class 10 ngt l 350 s, cho ng cong Class 20 ngt l 700 s, v cho ng cong Class 30 ngt l 1050 s.

t } P 3006

Parameters

ACS550 Users Manual

141

Code Description 3007 MOT LOAD CURVE Thit lp ti hot ng cho php t a ca ng c. khi thit lp n 100%, ti ti a cho php bng vi gi tr ca tham s 9906 MOTOR NOM CURR. iu chnh mc ng cong ti nu nhit mi trng khc vi danh nh . 3008 ZERO SPEED LOAD Thit lp dng in ti a cho php ti tc khng. gi tr l tng i 9906 MOTOR NOM CURR. 3009 BREAK POINT FREQ Thit lp tn s im gy cho ng cong ti ng c. P 3009 V d : Thi gian ngt bo v nhit khi cc thng s 3006 MOT THERM TIME, 3007 MOT LOAD CURVE v 3008 ZERO SPEED LOAD c gi tr mc nh. 3.5 3.0 2.5 2.0 1.5 1.0 0.5 fO/fBRK 0 0 3010 0.2 0.4 0.6 0.8 1.0 1.2 STALL FUNCTION Tham s ny quy nh hot ng ca chc nng Stall. Bo v ny hot ng nu bin tn hot ng trong khu vc ngng chy (xem hnh) thi gian xc nh bi 3012 STALL TIME. gii hn s dng c xc nh trong nhm 20: LIMITS bi 2017 MAX TORQUE 1, 2018 MAX TORQUE 2, hoc gii hn trong u vo COMM . 0 = NOT SEL bo v ngng chy l khng s dng. 1 = FAULT khi bin tn hot ng trong khu vc ngng chy thi gian c thit lp bi 3012 STALL TIME: bin tn dng theo qun tnh. mt du hiu li c hin th. 2 = ALARM khi bin tn hot ng trong khu vc ngng chy thi gian c thit lp bi 3012 STALL TIME: mt du hiu bo ng c hin th. bo ng bin mt khi bin tn ra khi khu vc ngng chy thi gian c thit lp bi tham s 3012 STALL TIME. 3011 STALL FREQUENCY t gi tr tham s tn s ny cho chc nng Stall. Hy tham kho hnh . 3012 3017 STALL TIME t gi tr tham s thi gan ny cho chc nng Stall. EARTH FAULT Xc nh bin tn phn ng nu bin tn pht hin li ni t trong ng c hoc cp ng c . bin tn gim st Li ni t trong khi bin tn ang chy, v trong khi bin tn khng chy. xem thm tham s 3023 WIRING FAULT. 0 = DISABLE bin tn khng phn ng li ni t. 1 = ENABLE li ni t hin th li 16 (EARTH FAULT), v (nu ang chy) bin tn dng theo qun tnh. IO /IN A Output current (%) relative to 9906 MOTOR NOM CURR 150

P 3007 100 P 3008 50 Frequency

60 s 90 s 180 s 300 s 600 s IO = dng in u ra IN = dng in danh nh ng c fO = tn s u ra fBRK = tn s im t A = thi gian ngt

Torque/ Current Stall region 95%

User
limit

f P 3011 Stall frequency

Parameters

142

ACS550 Users Manual

Code Description 3018 COMM FAULT FUNC Xc nh bin tn phn ng nu truyn thng fieldbus b mt. 0 = NOT SEL khng phn ng. 1 = FAULT hin th mt li (28, SERIAL 1 ERR) v bin tn dng theo qun tnh. 2 = CONST SP 7 hin th mt bo ng (2005, I/O COMM) v t tc s dng 1208 CONST SPEED 7. This tc bo ng vn hot ng cho n khi fieldbus vit mt gi tr tham chiu mi. 3 = LAST SPEED hin th mt bo ng (2005, I/O COMM) v t tc s dng vi cp hot ng mi nht. gi tr ny l tc trung bnh trong 10 giy cui cng. tc bo ng ny vn hot ng cho n khi fieldbus vit mt gi tr tham chiu mi Cnh bo! Nu bn chn CONST SP 7, hoc LAST SPEED, chc chc rng hot ng tip theo l an ton khi truyn thng fieldbus b mt. 3019 COMM FAULT TIME Thit lp thi gian li giao tip c s dng vi 3018 COMM FAULT FUNC. gii thiu tm tc truyn thng fieldbus khng c xem l li nu chng t hn gi tr COMM FAULT TIME . 3021 AI1 FAULT LIMIT Thit lp mc li cho u vo tng t 1. xem 3001 AI<MIN FUNCTION. 3022 AI2 FAULT LIMIT Thit lp mc li cho u vo tng t 2. xem 3001 AI<MIN FUNCTION. 3023 WIRING FAULT Xc nh bin tn phn ng n vt qua li n pht hin li ni t khi bin tn khng chy. khi bin tn khng chy n gim st: kt ni khng ng ngun in u vo n u ra bin tn (bin tn c th hin th li 35, OUTPUT WIRING nu cc kt ni khng ph hp c pht hin). li ni t (bin tn c th hin th li 16, EARTH FAULT nu mt li ni t c pht hin). xem thm tham s 3017 EARTH FAULT. 0 = DISABLE bin tn khng phn ng n mt trong cc kt qu gim st trn. 1 = ENABLE bin tn hin th li khi gim st pht hin vn . 3024 CB TEMP FAULT Xc nh bin tn phn ng n kim sot qu nng board . Khng phi cho bin tn vi mt kim sot board OMIO. 0 = DISABLE khng phn ng. 1 = ENABLE hin th li 37 (CB OVERTEMP) v bin tn dng theo qun tnh.

Parameters

ACS550 Users Manual

143

nhm 31: AUTOMATIC RESET Nhm ny quy nh iu kin t ng reset. T ng reset xy ra sau khi mt li c th c pht hin. bin tn gi mt thit lp thi gian tr, sau t ng khi ng li. Bn c th gii hn s ca reset trong mt khong thi gian quy nh v thit lp t ng reset cho mt lot cc li.
Code Description 3101 NUMBER OF TRIALS Thit lp s ca cho php t ng reset trong thi gian dng th xc nh bi 3102 TRIAL TIME. nu s ca t ng reset vt qu gii hn ny (trong thi gian th nghim) , bin tn ngn nga t ng reset v vn dng li , . khi ng li sau yu cu phi reset thnh cng t bng in khin hoc t mt ngun c chn bi tham s 1604 FAULT RESET SEL. 3102 TRIAL TIME Thit lp khong thi gian c s dng cho m v gii hn s ca reset . xem 3101 NUMBER OF TRIALS. 3103 DELAY TIME Thit lp thi gian tr gia pht hin li v khi ng li bin tn. nu DELAY TIME = zero, bin tn reset ngay lp tc. 3104 AR OVERCURRENT Thit lp t ng reset cho chc nng qu dng on hoc off. 0 = DISABLE v hiu ha t ng reset. 1 = ENABLE cho php t ng reset. t ng resets li (OVERCURRENT) sau khi thit lp tr bi 3103 DELAY TIME, v bin tn tip tc hot ng bnh thng. 3105 AR OVERVOLTAGE Thit lp t ng reset cho chc nng qu p on hoc off. 0 = DISABLE v hiu ha t ng reset. 1 = ENABLE cho php t ng reset. t ng resets li (DC OVERVOLT) sau khi thit lp tr bi 3103 DELAY TIME, v bin tn tip tc hot ng bnh thng. 3106 AR UNDERVOLTAGE Thit lp t ng reset cho chc nng thp p on hoc off. 0 = DISABLE v hiu ha t ng reset. 1 = ENABLE cho php t ng reset. t ng resets li (DC UNDERVOLT) sau khi thit lp tr bi 3103 DELAY TIME, v bin tn tip tc hot ng bnh thng. 3107 AR AI<MIN Thit lp t ng reset cho cc u vo tng t t hn gi tr nh nht chc nng on hoc off. 0 = DISABLE v hiu ha t ng reset. 1 = ENABLE cho php t ng reset. t ng resets li (AI<MIN) sau khi thit lp tr bi 3103 DELAY TIME, v bin tn tip tc hot ng bnh thng. Cnh bo ! khi tn hiu u vo tng t c phc hi , bin tn c th c khi ng li, ngay c khi dng lu. Hy chc chn rng t ng, khi ng tr di s khng gy thit hi v vt cht v/hoc thit hi thit b 3108 AR EXTERNAL FLT Thit lp t ng reset cho chc nng li ngoi on hoc off. 0 = DISABLE v hiu ha t ng reset. 1 = ENABLE cho php t ng reset. t ng resets li (EXT FAULT 1 hoc EXT FAULT 2) sau khi thit lp tr bi 3103 DELAY TIME, v bin tn tip tc hot ng bnh thng. v d: ba li xy ra trong thi gian th nghim . cui cng l reset ch nu gi tr cho 3101 NUMBER OF TRIALS l 3 hoc nhiu hn. Trial time Time X x = Automatic reset XX

Parameters

144

ACS550 Users Manual

nhm 32: SUPERVISION Nhm ny xc nh gim st cho n ba tn hiu t nhm 01: OPERATING DATA. Gim st theo di mt tham s ch nh v ng in cho mt u ra relay nu tham s vt qua mt gii hn xc nh. S dng nhm 14: RELAY OUTPUTS xc nh relay v xem tip kch hot relay khi tn hiu nh vy l qu thp hoc qu cao .
Code 3201 Description SUPERV 1 PARAM Chn tham s gim st u tin. phi c mt s ca tham s t nhm 01: OPERATING DATA. 100 = NOT SELECTED khng chn tham s. 101159 chn tham s 01010159. nu tham s gim st vt qua gii hn, mt u ra relay c cp in . gii hn gim st c xc nh trong nhm ny. u ra relay c xc nh trong nhm 14: RELAY OUTPUTS (xc nh cng quy nh gii hn c theo di gim st). LO HI

LO HI Ch : trng hp LO HI trnh bi mt tr bnh thng. Gi tr ca tham s gim st


HI (3203) LO (3202)

Case A D liu hot ng gim st s dng u ra relay, khi LOHI. trng hp A = tham s 1401 RELAY OUTPUT 1 (hoc 1402 RELAY Energized (1) t OUTPUT 2, v.v.) gi tr l SUPRV1 OVER hoc SUPRV2 OVER. 0 S dng cho gim st khi /nu tn hiu gim st vt qu gii Case B hn nht nh. relay vn hot ng cho n khi gi tr gim st nh di gii hn thp. Energized (1) t trng hp B = tham s 1401 RELAY OUTPUT 1 (hoc 1402 RELAY 0 OUTPUT 2, vv.) gi tr l SUPRV1 UNDER hoc SUPRV2 UNDER. S dng cho gim st khi /nu tn hiu gim st gim xung di gii hn nht nh. relay vn hot ng n khi gi tr gim LO > HI ch : trng hp LO>HI trnh bi mt tr c bit vi st tng ln trn gii hn cao. hai gii hn gim st ring bit. LO > HI D liu hot ng gim st s dng u ra relay, khi LO>HI. Gi tr ca tham s gim st Active limit gii hn thp (HI 3203) l hot ng ban u v vn hot ng cho n khi tham s gim st n mc gii hn cao nht LO (3202) (LO 3202), gii hn hot ng gii hn . Gii hn vn hot HI (3203) ng n khi cc thng s gim st i di mc gii hn thp nht (HI 3203), lm gii hn hot ng . trng hp A= tham s 1401 RELAY OUTPUT1(hoc 1402 RELAY OUTPUT 2, v,v.) gi tr l SUPRV1 OVER hoc SUPRV2 OVER. Case A Ban u relay khng c cp in. n c cp in bt c khi no cp in (1)thng s gim st trn gii hn hot ng. 0 trng hpB= tham s 1401 RELAY OUTPUT1(hoc 1402 RELAY OUTPUT 2, v,v.) gi tr l SUPRV1 UNDER hoc SUPRV2 UNDER. Case B ban u relay c cp in. n khng c cp in bt c khi Energized (1) no tham s gim st di mc gii hn. 3202 SUPERV 1 LIM LO Thit lp gii hn thp cho tham s gim st u tin. Xem 3201 SUPERV 1 PARAM trn. 3203 SUPERV 1 LIM HI Thit lp gii hn cao cho tham s gim st u tin. Xem 3201 SUPERV 1 PARAM trn. 3204 3205 3206 SUPERV 2 PARAM Chn tham s gim st th hai. xem 3201 SUPERV 1 PARAM trn. SUPERV 2 LIM LO Thit lp gii hn thp cho tham s gim st th hai. Xem 3204 SUPERV 2 PARAM trn. SUPERV 2 LIM HI Thit lp gii hn cao cho tham s gim st th hai. Xem 3204 SUPERV 2 PARAM trn. 0

Parameters

ACS550 Users Manual

145

Code Description 3207 SUPERV 3 PARAM Chn tham s gim st th hai. xem. See 3201 SUPERV 1 PARAM trn. 3208 SUPERV 3 LIM LO Thit lp gii hn thp cho tham s gim st th ba. xem 3207 SUPERV 3 PARAM trn. 3209 SUPERV 3 LIM HI Thit lp gii hn cao cho tham s gim st th ba. xem 3207 SUPERV 3 PARAM trn.

Parameters

146

ACS550 Users Manual

nhm 33: INFORMATION Nhm ny cung cp d liu thng tin chng trnh hin ti ca bin tn: Phin bn v ngy kim tra .
Code Description 3301 3302 3303 3304 FIRMWARE Phin bn vi chng trnh ca bin tn. LOADING PACKAGE Phin bn gi ti. TEST DATE Cha ngy kim tra (yy.ww). DRIVE RATING Ch ra phm vi dng in v in p bin tn. nh dng l XXXY, trong : XXX = phm vi dng in danh nh ca bin tn trong amper. Nu hin ti, A ch dn mt im thp phn trong phm vi dng in. v d XXX = 8A8 ch ra phm vi dng in danh nh l 8.8 A. Y = phm vi in p ca bin tn, trong Y = : 2 tc l phm vi 208240 V. tc l phm vi 380480 V . 6 tc l phm vi 500600 V . 3305 PARAMETER TABLE C cc phin bn ca bng thng s s dng trong bin tn.

Parameters

ACS550 Users Manual

147

nhm 34: PANEL DISPLAY Nhm ny xc nh ni dung hin th ca bng iu khin (khu vc gia), khi bng iu khin ch u ra.
Code Description 3401 SIGNAL1 PARAM Chn tham s hin th u tin hin th (theo s) trn bng iu khin . nh ngha trong nhm ny xc nh ni dung hin th khi bng iu khin trong ch kim sot. bt k s tham s trong nhm 01: OPERATING DATA c th c chn . s dng cc tham s sau y , gi tr hin th c thu nh chuyn i, cho cc n v thun tin v/hoc hin th nh th thanh. cc con s xc nh c chn thc hin bi tham s trong nhm ny . 100 = NOT SELECTED tham s u tin khng c hin th. 101159 hin th tham s 01010159. nu tham s khng tn ti hin th cho thy n.a. P 3404 DIR 3402 SIGNAL1 MIN Xc nh gi tr d kin cho tham s hin th u tin. S dng tham s 3402, 3403, 3406 v 3407, v d chuyn i mt nhm Tham s nhm 01: OPERATING DATA, chn hn nh 0102 SPEED (trong rpm) n tc ca bng ti iu khin bi ng c (trong ft/min). Cho chuyn i nh vy, gi tr ngun trong hnh l min. v max. tc ng c, v hin th gi tr min tng ng . v max. tc bng ti . S dng tham s 3405 chn ng n v cho hin th. Ch : chn n v khng chuyn i cc gi tr . Tham s l khng hiu qu nu tham s 3404 OUTPUT1 DSP FORM = 9 (DIRECT). 3403 SIGNAL1 MAX Xc nh gi tr d kin ln nht cho tham s hin th u tin. Ch : cc tham s khng hiu qu nu tham s 3404 OUTPUT1 DSP FORM = 9 (DIRECT). 3404 OUTPUT1 DSP FORM Xc nh v tr im thp phn cho tham s hin th u tin. 07 Xc nh v tr im thp phn. nhp ch s mong mun bn phi im thp phn . xem bng cho mt v d s dng (3.14159). 8 = BAR METER ch nh hin th dng th thanh. 9 = DIRECT v tr im thp phn v n v o lng c trng vi tn hiu ngun. xem nhm 01: OPERATING DATA tham s lit k trong phn Complete parameter list trn trang 85 cho phn gii (trong ch ra v tr im thp phn) v cc n v o lng. 3404 value 0 1 2 3 4 5 6 7 8 9 Display Range +3 -32768+32767 (Signed) + 3.1 + 3.14 + 3.142 3 065535 (Unsigned) 3.1 3.14 3.142 Hin th tc bar. V tr im thp phn v n v nh tn hiu ngun . Display value P 3407 LOC P 3401 (137) P 3408 (138) P 3415 (139) DIR LOC HZ P 3404 P 3405 49.1Hz

49.1 Hz 0.5 A 10.7 %


00:00

MENU 5.0Hz 50%

0.4 A 24.4 %
00:00

MENU

P 3406

P3402

P 3403 Source value

Parameters

148

ACS550 Users Manual

Code Description 3405 OUTPUT1 UNIT Chn n v s dng vi cc thng s hin th u tin. Ch : thng s khng hiu qu nu thng s 3404 OUTPUT1 DSP FORM = 9 (DIRECT). 0 = NO UNIT 1=A 2=V 3 = Hz 4=% 5=s 6=h 7 = rpm 8 = kh 9 = C 10 = lb ft 11 = mA 12 = mV 13 = kW 14 = W 15 = kWh 16 = F 17 = hp 18 = MWh 19 = m/s 20 = m3/h 21 = dm3/s 22 = bar 23 = kPa 24 = GPM 25 = PSI 26 = CFM 27 = ft 28 = MGD 29 = inHg 30 = FPM 31 = kb/s 32 = kHz 33 = ohm 34 = ppm 35 = pps 36 = l/s 37 = l/min 38 = l/h 39 = m3/s 40 = m3/m 41 = kg/s 42 = kg/m 43 = kg/h 44 = mbar 45 = Pa 46 = GPS 47 = gal/s 48 = gal/m 49 = gal/h 50 = ft3/s 51 = ft3/m 52 = ft3/h 53 = lb/s 54 = lb/m 55 = lb/h 56 = FPS 57 = ft/s 58 = inH2O 59 = in wg 60 = ft wg 61 = lbsi 62 = ms 63 = Mrev 64 = d 65 = inWC 66 = m/min 67 = Nm

Cc n v sau y c ch cho vic hin th thanh . 117 = %ref 119 = %dev 121 = % SP 123 = Iout 118 = %act 120 = % LD 122 = %FBK 124 = Vout 3406 OUTPUT1 MIN Thit lp gi tr nh nht cho tham s hin th u tn.

125 = Fout 126 = Tout

127 = Vdc

Ch : thng s khng hiu qu nu thng s 3404 OUTPUT1 DSP FORM = 9 (DIRECT). 3407 OUTPUT1 MAX Thit lp gi tr ln nht cho tham s hin th u tn. Ch : thng s khng hiu qu nu thng s 3404 OUTPUT1 DSP FORM = 9 (DIRECT). 3408 3409 3410 3411 3412 3413 3414 SIGNAL2 PARAM Chn tham s hin th th hai (theo s) trn bng iu khin. xem tham s 3401. SIGNAL2 MIN Xc nh gi tr d kin nh nht cho tham s hin th th hai. Xem tham s 3402. SIGNAL2 MAX Xc nh gi tr d kin ln nht cho tham s hin th th hai. Xem tham s 3403. OUTPUT2 DSP FORM Xc nh v tr im thp phn cho tham s hin th th hai. Xem tham s 3404. OUTPUT2 UNIT Chn n v s dng vi tham s hin th th hai. Xem tham s 3405. OUTPUT2 MIN Thit lp gi tr hin th nh nht cho tham s hin th th hai. Xem tham s 3406. OUTPUT2 MAX Thit lp gi tr hin th ln nht cho tham s hin th th hai. Xem tham s 3407. 3415 SIGNAL3 PARAM Chn tham s hin th th ba (theo s) trn bng iu khin. xem tham s 3401. 3416 SIGNAL3 MIN Xc nh gi tr d kin nh nht cho tham s hin th th ba. Xem tham s 3402. 3417 3418 3419 3420 SIGNAL3 MAX Xc nh gi tr d kin ln nht cho tham s hin th th ba. Xem tham s 3403. OUTPUT3 DSP FORM Xc nh v tr im thp phn cho tham s hin th th ba. Xem tham s 3404. OUTPUT3 UNIT Chn n v s dng vi tham s hin th th ba. Xem tham s 3405. OUTPUT3 MIN Thit lp gi tr hin th nh nht cho tham s hin th th ba. Xem tham s 3406.

Parameters

ACS550 Users Manual

149

Code Description 3421 OUTPUT3 MAX Thit lp gi tr hin th ln nht cho tham s hin th th ba. Xem tham s 3407.

Parameters

150

ACS550 Users Manual

nhm 35: MOTOR TEMP MEAS Nhm ny quy nh vic pht hin v bo co mt li tim nng c th qu nhit ng c , nh c xc nh bi mt cm bin nhit . Cc kt ni chun c xc nh di y .
Mt cm bin Ba cm bin
AI1 AI1

Motor

Motor
AGND

AGND

T
AO1 AGND

T
AO1 AGND

10 nF

10 nF

Cnh bo! IEC 60664 yu cu cch in gp i hoc gia c gia cc phn sng v cc b phn c th dn in hoc khng dn in nhng khng kt ni vi bo v ni t . thc hin yu cu ny, kt ni mt in tr nhit (v cc thnh phn tng t khc) kim sot thit b u cui ca bin tn s dng bt k nhng la chn thay th: ring in tr nhit t b phn sng ca ng c vi cch in tng cng gp i . . bo v tt c cc mch kt ni n u vo s v tng t ca bin tn. Bo v chng li lin lc, v cch nhit t cc mch in p thp khc vi cch in c bn (nh mc ca cp in p nh mch chnh ca bin tn ). s dng mt relay nhit bn ngoi . Cch nhit relay phi mc cao nht i vi cp in p nh mch chnh ca bin tn. Hnh di y cho thy cc kt ni thay th in tr nhit ti cui ng c l chn cp phi c ni t qua mt t in 10 nF . Nu iu ny khng th, l chn cha c ni t.
Thermistor relay: THERM(0) or THERM(1) Thermistor relay
THERM(0)

Control board DI6 +24 V DC T 10 nF Control board DI6 +24 V DC

T Motor

Motor

Parameters

ACS550 Users Manual

151

Cho li khc, hoc cho d on qu nhit ng c bng cch s dng m hnh, xem nhm 30: FAULT FUNCTIONS.
Code Description 3501 SENSOR TYPE Xc nh loi cm bin nhit ng c s dng, PT100 (C), PTC (ohm) hoc in tr nhit. Xem tham s 1501 AO1 CONTENT SEL v 1507 AO2 CONTENT SEL. 0 = NONE 1 = 1 x PT100 cu hnh cm bin s dng mt cm bin PT 100 . u ra tng t AO1 hoc AO2 dng iin cung cp lin tc thng qua cm bin. cc cm bin tng in tr nh nhit ng c tng, cng nh in p trn cm bin. chc nng o nhit c in p thng qua u vo tng t AI1 hoc AI2 v chuyn i n n C. 2 = 2 x PT100 cu hnh cm bin s dng hai cm bin PT100 . hot ng l tng t nh i vi 1 x PT100 trn. 3 = 3 x PT100 cu hnh cm bin s dng ba cm bin PT100 . ohm hot ng l tng t nh i vi 1 x PT100 trn. 4000 4 = PTC cu hnh cm bin s dng PTC. u ra tng t cung cp mt dng khng i thng qua cm bin. 1330 in tr ca cm bin tng mnh khi nhit ng c tng hn nhit tham chiu PTC (Tref), cng nh in p trn in tr . chc nng o nhit c in p thng qua u vo tng t 550 AI1 v chuyn i n thnh ohm. hnh di y cho thy kt ni cm bin PTC gi tr in tr nh mt chc nng ca nhit hot ng ng c. 100 Nhit Bnh thng Qu cao in tr < 3 kohm > 28 kohm

5 = THERM(0) cu hnh s dng mt cm bin nhit . bo v nhit ng c c kch hot thng qua u vo s. Kt ni cm bin PTC hoc tip im thng ng relay nhit n u vo s. Bin tn c trng thi u vo s nh hin th trong bng trn. khi cc u vo s l 0 ng c qu nng. xem hnh gii thiu v nhm ny. 6 = THERM(1) cu hnh s dng hai cm bin nhit . bo v nhit ng c c kch hot thng qua u vo s. Kt ni thng m relay nhit n mt u vo s . Bin tn c trng thi u vo s nh hin th trong bng trn. khi cc u vo s l 1 ng c qu nng. xem hnh gii thiu v nhm ny. 3502 INPUT SELECTION Xc nh s dng u vo cho cm bin nhit . 1 = AI1 PT100 v PTC. 2 = AI2 PT100 v PTC. 38 = DI1DI6 nhit in tr 3503 ALARM LIMIT Xc nh gii hn bo ng cho o nhit ng c. nhit ng c trn gii hn ny, bin tn hin th bo ng (2010, MOTOR TEMP) cho in tr nhit: 0 kh kch hot 1 kch hot 3504 FAULT LIMIT Xc nh gii hn li cho o nhit ng c. nhit ng c trn gii hn ny, bin tn hin th li (9, MOT OVERTEMP) v dng bin tn. cho in tr nhit: 0 kh kch hot 1 kch hot

Parameters

152

ACS550 Users Manual

nhm 36: TIMED FUNCTIONS Nhm ny xc nh chc nng hn gi. chc nng hn gi bao gm: bn khi ng ngy v dng thi gian . bn khi ng tun, dng v tng cng thi gian bn gi cho tp hp chn giai on vi nhau. Hn gi c th c kt ni vi nhiu khong thi gian v mt khong thi gian c th trong nhiu gi .
Time Period 1 3602 START TIME 1 3603 STOP TIME 1 3604 START DAY 1 3605 STOP DAY 1 Time Period 2 3606 START TIME 2 3607 STOP TIME 2 3608 START DAY 2 3609 STOP DAY 2 Time Period 3 3610 START TIME 3 3611 STOP TIME 3 3612 START DAY 3 3613 STOP DAY 3 Time Period 4 3614 START TIME 4 3615 STOP TIME 4 3616 START DAY 4 3617 STOP DAY 4 Booster 3622 BOOSTER SEL 3623 BOOSTER TIME Timer 3 3628 TIMED FUNC 3 SRC Timer 4 3629 TIMED FUNC 4 SRC

Timer 1 3626 TIMED FUNC 1 SRC Timer 2 3627 TIMED FUNC 2 SRC

Mt tham s c th c kt ni ch vi mt b m thi gian .


Timer 1 3626 TIMED FUNC 1 SRC Timer 2 3627 TIMED FUNC 2 SRC 1001 EXT1 COMMANDS 1002 EXT2 COMMANDS 1102 EXT1/EXT2 SEL 1201 CONST SPEED SEL 1401 RELAY OUTPUT 11403 RELAY OUTPUT 3 1410 RELAY OUTPUT 41412 RELAY OUTPUT 6 4027 PID 1 PARAM SET 8126 TIMED AUTOCHNG

Parameters

ACS550 Users Manual

153

Code Description 3601 TIMERS ENABLE Chn ngun cho tn hiu cho php hn gi. 0 = NOT SEL chc nng hn gi b v hiu ha. 1 = DI1 xc nh u vo s DI1 nh tn hiu cho php chc nng hn gi . u vo s phi c kch hot kch hot chc nng hn gi. 26 = DI2DI6 xc nh u vo s DI2DI6 nh tn hiu cho php chc nng hn gi. 7 = ACTIVE chc nng hn gi l cho php. -1 = DI1(INV) xc nh ngc u vo s DI1 nh tn hiu cho php chc nng hn gi. u vo s phi c kh kch hot kch hot chc nng hn gi. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh tn hiu cho php chc nng hn gi. 3602 START TIME 1 Xc nh thi gian khi ng hng ngy. thi gian c th thay i trong bc ca 2 giy. nu gi tr tham s l 07:00:00, thi gian c kch hot lc 7 a.m. hnh di y cho thy nhiu gi trn cc ngy khc nhau . 20:30:00 17:00:00 15:00:00 13:00:00 12:00:00 10:30:00 Time period 1 09:00:00 00:00:00 Mon Tue Wed Thu Fri Sat Sun 3603 STOP TIME 1 Xc nh thi gian dng hng ngy. thi gian c th thay i trong bc ca 2 giy. nu gi tr tham s l 09:00:00, thi gian c kh kch hot lc 9 a.m. START DAY 1 Xc nh thi gian khi ng ngy trong tun. 1 = MONDAY7 = SUNDAY nu gi tr tham s l 1, b m thi gian tun hot ng t na m th hai (00:00:00). STOP DAY 1 Xc nh thi gian dng ngy trong tun. 1 = MONDAY7 = SUNDAY nu gi tr tham s l 5, b m thi gian tun ngng hot ng t na m th su(23:59:58). START TIME 2 Xc nh thi gian thi gian 2 khi ng hng ngy. xem tham s 3602. STOP TIME 2 Xc nh thi gian dng hng ngy b m thi gian 2. xem tham s 3603. START DAY 2 Xc nh b m thi gian 2 ngy khi ng trong tun. xem tham s 3604. STOP DAY 2 Xc nh b m thi gian 2 ngy dng trong tun. xem tham s 3605. START TIME 3 Xc nh thi gian thi gian 3 khi ng hng ngy. xem tham s 3602. STOP TIME 3 Xc nh thi gian dng hng ngy b m thi gian 3. xem tham s 3603. Time period 3 Time period 4

Time period 2

3604

3605

3606

3607

3608

3609

3610

3611

Parameters

154

ACS550 Users Manual

Code Description 3612 START DAY 3 Xc nh b m thi gian 3 ngy khi ng trong tun. xem tham s 3604. STOP DAY 3 Xc nh b m thi gian 3 ngy dng trong tun. xem tham s 3605. START TIME 4 Xc nh thi gian thi gian 4 khi ng hng ngy. xem tham s 3602. STOP TIME 4 Xc nh thi gian dng hng ngy b m thi gian 4. xem tham s 3603. START DAY 4 Xc nh b m thi gian 4 ngy khi ng trong tun. xem tham s 3604. STOP DAY 4 Xc nh b m thi gian 3 ngy dng trong tun. xem tham s 3605. BOOSTER SEL Chn ngun cho tn hiu tng cng . 0 = NOT SEL tn hiu tng cng b v hiu ha. 1 = DI1 xc nh DI1 nh tn hiu tng cng. 26 = DI2DI6 xc nh DI2DI6 nh tn hiu tng cng. -1 = DI1(INV) xc nh ngc u vo KTS DI1 nh tn hiu tng cng. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo KTS DI2 DI6 nh tn hiu tng cng. BOOSTER TIME Xc nh thi gian tng cng ON. Thi gian bt u khi tn hiu tng cng c gii phng. Nu gi tr tham s l 01:30:00, tng cng l hot ng cho 1 gi v 30 pht sau khi hot ng DI c gii phng . Booster active

3613

3614

3615

3616

3617

3622

3623

Activation DI

Booster time 3626 TIMED FUNC 1 SRC Xc nh khong thi gian c s dng bi tnh gi. 0 = NOT SEL khng c khong thi gian c chn. 1 = T1 khong thi gian 1 chn trong b nh thi. 2 = T2 khong thi gian 2 chn trong b nh thi. 3 = T1+T2 khong thi gian 1 v 2 chn trong b nh thi. 4 = T3 khong thi gian 3 chn trong b nh thi. 5 = T1+T3 khong thi gian 1 v 3 chn trong b nh thi. 6 = T2+T3 khong thi gian 2 v 3 chn trong b nh thi. 7 = T1+T2+T3 khong thi gian 1, 2 v 3 ch trong b nh thi. 8 = T4 khong thi gian 4 chn trong b nh thi. 9 = T1+T4 khong thi gian 1 v 4 chn trong b nh thi. 10 = T2+T4 khong thi gian 2 v 4 chn trong b nh thi. 11 = T1+T2+T4 khong thi gian 1, 2 v 4 chn trong b nh thi. 12 = T3+T4 khong thi gian 3 v 4 chn trong b nh thi. 13 = T1+T3+T4 khong thi gian 1, 3 v 4 chn trong b nh thi. 14 = T2+T3+T4 khong thi gian 2, 3 v 4 chn trong b nh thi. 15 = T1+T2+T3+T4 khong thi gian 1, 2, 3 v 4 chn trong b nh thi. 16 = BOOSTER tng cng chn trong b nh thi. 17 = T1+B tng cng v khong thi gian 1 chn trong b nh thi. 18 = T2+B tng cng v Time Period 2 chn trong b nh thi. 19 = T1+T2+B tng cng v khong thi gian 1 v 2 chn trong b nh thi. 20 = T3+B tng cng v khong thi gian 3 chn trong b nh thi.

Parameters

ACS550 Users Manual

155

Code Description 21 = T1+T3+B tng cng v khong thi gian 1 v 3 chn trong b nh thi. 22 = T2+T3+B tng cng v khong thi gian 2 v 3 chn trong b nh thi. 23 = T1+T2+T3+B tng cng v khong thi gian 1, 2 v 3 chn trong b nh thi. 24 = T4+B tng cng v khong thi gian 4 chn trong b nh thi. 25 = T1+T4+B tng cng v khong thi gian 1 v 4 chn trong b nh thi. 26 = T2+T4+B tng cng v khong thi gian 2 v 4 chn trong b nh thi. 27 = T1+T2+T4+B tng cng v khong thi gian 1, 2 v 4 chn trong b nh thi. 28 = T3+T4+B tng cng v khong thi gian 3 v 4 chn trong b nh thi. 29 = T1+T3+T4+B tng cng v khong thi gian 1, 3 v 4 chn trong b nh thi. 30 = T2+T3+T4+B tng cng v khong thi gian 2, 3 v 4 chn trong b nh thi. 31 = T1+2+3+4+B tng cng v khong thi gian 1, 2, 3 v 4 chn trong b nh thi. 3627 3628 3629 TIMED FUNC 2 SRC xem tham s 3626. TIMED FUNC 3 SRC xem tham s 3626. TIMED FUNC 4 SRC xem tham s 3626.

Parameters

156

ACS550 Users Manual

nhm 37: USER LOAD CURVE Nhm ny xc nh gim st ca ngi s dng iu chnh ng cong ti (momen xon ng c nh chc nng ca tn s ). ng cong xc nh bi nm im.
Code Description 3701 USER LOAD C MODE Ch gim st cho ngi s dng iu chnh ng cong ti Chc nng ny thay th cun dy non ti gim st trong nhm 30: FAULT FUNCTIONS. m phng n, xem phn Correspondence with the obsolete underload supervision trn trang 157. 0 = NOT SEL gim st khng c kch hot. 1 = UNDERLOAD gim st momen xon xung thp hn ng cong non ti. 2 = OVERLOAD gim st momen xon vt qu ng cong qu ti. 3 = BOTH gim st momen xon ri xung ng cong non ti hoc vt qu ng cong qu ti . Motor torque (%) Overload area
P3706 P3709 P3712

P3715 P3714

P3718 P3717

Allowed operating area


P3711 P3705

Underload area
P3708 P3704 P3707 P3710 P3713 P3716

Output frequency (Hz) 3702 USER LOAD C FUNC Hot ng mong mun trong thi gian gim st ti. 1 = FAULT mt li c to ra khi cc iu kin xc nh bi 3701 USER LOAD C MODE hp l di hn thi gian thit lp bi 3703 USER LOAD C TIME. 2 = ALARM mt bo ng c to ra khi cc iu kin xc nh bi 3701 USER LOAD C MODE hp l di hn na ca thi gian xc nh bi 3703 USER LOAD C TIME. 3703 USER LOAD C TIME Xc dnh thi gian gii hn to ra mt li. mt na thi gian ny c s dng nh l gii hn to ra mt bo ng. 3704 LOAD FREQ 1 Xc nh gi tr tn s ca ng cong ti u tin xc nh im . phi nh hn 3707 LOAD FREQ 2. 3705 LOAD TORQ LOW 1 Xc nh gi tr momen xon ca ng cong non ti th nht xc nh im. phi nh hn 3706 LOAD TORQ HIGH 1. 3706 3707 LOAD TORQ HIGH 1 Xc nh gi tr momen xon ca ng cong qu ti th nht xc nh im. LOAD FREQ 2 Xc nh gi tr tn s ca ng cong ti th hai xc nh im. phi nh hn 3710 LOAD FREQ 3. 3708 LOAD TORQ LOW 2 Xc nh gi tr momen xon ca ng cong non ti th hai xc nh im. phi nh hn 3709 LOAD TORQ HIGH 2. 3709 3710 LOAD TORQ HIGH 2 Xc nh gi tr momen xon ca ng cong qu ti th hai xc nh im. LOAD FREQ 3 Xc nh gi tr tn s ca ng cong ti th ba xc nh im. phi nh hn 3713 LOAD FREQ 4. 3711 LOAD TORQ LOW 3 Xc nh gi tr momen xon ca ng cong non ti th ba xc nh im. phi nh hn 3712 LOAD TORQ HIGH 3. 3712 LOAD TORQ HIGH 3 Xc nh gi tr momen xon ca ng cong qu ti th ba xc nh im.

Parameters

ACS550 Users Manual

157

Code Description 3713 LOAD FREQ 4 Xc nh gi tr tn s ca ng cong ti th t xc nh im. phi nh hn 3716 LOAD FREQ 5 3714 LOAD TORQ LOW 4 Xc nh gi tr momen xon ca ng cong non ti th t xc nh im. phi nh hn 3715 LOAD TORQ HIGH 4. 3715 3716 3717 LOAD TORQ HIGH 4 Xc nh gi tr momen xon ca ng cong qu ti th t xc nh im. LOAD FREQ 5 Xc nh gi tr tn s ca ng cong ti th nm xc nh im. LOAD TORQ LOW 5 Xc nh gi tr momen xon ca ng cong non ti th nm xc nh im. phi nh hn 3718 LOAD TORQ HIGH 5. 3718 LOAD TORQ HIGH 5 Xc nh gi tr momen xon ca ng cong qu ti th nm xc nh im.

Tng ng vi gim st non ti khng dng na bo gi khng ng tham s 3015 UNDERLOAD CURVE cung cp 5 la chn ng cong c hin th trong hnh. c im cc tham s nh m t di y. nu ti xung thp di thit lp ng cong cho di hn thi gian thit lp bi tham s 3014 UNDERLOAD TIME (khng ng), bo v non ti c kch hot. ng cong 13 t ti a tn s nh mc ng c t bi tham s 9907 MOTOR
NOM FREQ. TM (%) 80

Underload curve types

3 70%

60

2 50%

40

5 30%

20

4 f N 2.4 N

TM = momen xon danh nh ca ng c. N = tn s danh nh ca ng c

nu bn mun m phng trng thi ca ng cong non ti c vi tham s nh trong cc ct t bng, thit lp tham s mi nh trong cc ct trng trong hai bng di y :
Obsolete parameters Underload supervision with parameters 30133015 (obsolete) 3013
UNDERLOAD FUNCTION

New parameters 3701


USER LOAD C MODE

3014
UNDERLOAD TIME

3702
USER LOAD C FUNC

3703
USER LOAD C TIME

No underload functionality Underload curve, fault generated Underload curve, alarm generated

0 1 2

t t

0 1 1

1 2

t 2t

Parameters

158

ACS550 Users Manual

Obs. par. 3015


UNDER LOAD CURVE

New parameters 3704


LOAD FREQ 1

3705
LOAD TORQ LOW 1

3707
LOAD FREQ 2

3708
LOAD TORQ LOW 2

3710
LOAD FREQ 3

3711
LOAD TORQ LOW 3

3713
LOAD FREQ 4

3714
LOAD TORQ LOW 4

3716
LOAD FREQ 5

3717
LOAD TORQ LOW 5

(Hz) EU 1 2 3 4 5 5 5 5 5 5 US 6 6 6 6 6

(%)

(Hz) EU US 38 37 37 88 86

(%)

(Hz) EU US 50 50 50 117 119

(%)

(Hz) EU US 60 60 60

(%)

(Hz) EU US

(%)

10 20 30 10 20

32 31 31 73 71

17 30 43 17 30

41 42 42 98 99

23 40 57 23 40

50 50 50

30 50 70 30 50

500 500 500 500 500 500 500 500 500 500

30 50 70 30 50

120 144 120 144

Parameters

ACS550 Users Manual

159

nhm 40: PROCESS PID SET 1 Nhm ny xc nh tp hp cc tham s c s dng cho qu trnh iu khin PID (PID1) . Thng thng ch cc thng s trong nhm ny l cn thit . B iu khin PID cc thit lp c bn Trong ch iu khin PID, bin tn so snh mt tnh hiu tham chiu (im t) n tn hiu thc t (phn hi) v t ng iu chnh tc ng c ph hp vi hai tn hiu. s khc nhau gia hai tn hiu l gi tr sai lch. thng thng ch iu khin PID c s dng, khi tc ca ng c cn c iu khin da trn p lc, dng chy hoc nhit . Trong a s trng hp khi ch c mt u d tn hiu n ACS550 ch nhm tham s 40 l cn thit. Sau y l s mch ca im t/tn hiu phn hi dng chy s dng tham s nhm 40.
Panel REF1 Panel REF 2 500% PID Setpoint -500% G40 PID1 P1106 017, 2021 19 PANEL LOC/REM selection LOC REM P1101 REF1 REF2

Panel REF2 AI Current Torque Power AI Current Torque Power P4016

P4017

P4014

P4015 PID Act Value

Panel REF 1 DI AI Comm REF 1 Panel REF 2 DI AI Comm REF 2 Panel REF2 P4010 AI1 AI2 Comm Internal AI P4016 Current Torque Power P4014 AI P4017 Current Torque Power P1106

P1103

G12 Const Speed

P1104 P1105

P1102 EXT 1 EXT 2

G12 Const Speed P1106 017, 2021 19

PID Setpoint P4012 P4013 G40 PID1 P4015 PID Act Value

P1107 P1108

PID1 Out

Ch : kch hot v s dng b iu khin PID, tham s 1106 phi c t n gi tr 19.

Parameters

160

ACS550 Users Manual

B iu khin PID cao cp ACS550 c hai b iu khin PID ring bit: qu trnh PID (PID1) v bn ngoi PID (PID2) Qu trnh PID (PID1) c 2 b thit lp ca cc thng s : qu trnh PID (PID1) SET1, xc nh trong nhm 40: PROCESS PID SET 1 v qu trnh PID (PID1) SET2, xc nh trong nhm 41: PROCESS PID SET 2 Bn c th chn gia hai b khc nhau bng cch s dng tham s 4027. Thng thng hai b iu khin PID khc nhau c s dng khi ti ca ng c thay i ng k t mt tnh hung khc . Bn c th s dng b iu khin PID (PID2) ngoi, xc nh trong nhm 42: EXT / TRIM PID, trong hai cch khc nhau: thay v s dng b iu khin PID b sung phn cng, bn c th thit lp u ra ca ACS550 kim sot mt my o sch tay ging nh mt van iu tit hoc mt van. Trong trng hp ny ,thit lp tham s 4230 n gi tr 0. (0 l gi tr mc nh.) bn c th s dng External PID (PID2) vi chnh hoc tinh chnh tc ca ACS550.
Code Description 4001 GAIN Xc nh tng ch ( li)cho b iu khin PID. phm vi thit lp l 0.1 100. 0.1, u ra b iu khin PID thay i mt phn mi so vi gi tr li. 100, u ra b iu khin PID thay i mt trm ln so vi gi tr li. S dng t c t l v gi tr thi gian kt hp iu chnh p ng cho h thng. mt gi tr thp cho t l tng ch v gi tr cao cho thi gian m bo hot ng n nh, nhng cung cp phn ng chm. Nu gi tr t l tng ch qu ln hoc thi gian tch ri qu ngn, h thng c th khng n nh. Phng php: thit lp ban u: 4001 GAIN = 0.1. 4002 INTEGRATION TIME = 20 giy. khi ng h thng v xem nu n t n im t nhanh trong khi duy tr hot ng n nh. Nu khng tng, GAIN (4001) cho n khi tn hiu thc t (hoc tc bin tn) dao ng lin tc. n c th cn thit khi ng v dng bin tn to ra dao ng ny. gim GAIN (4001) n khi ngng dao ng. t GAIN (4001) n 0,4 n 0,6 thi gian so vi gi tr trn. gim INTEGRATION TIME (4002) cho n khi tn hiu phn hi (hoc tc bin tn) dao ng lin tc. n c th cn thit khi ng v dng bin tn to ra dao ng ny. gim INTEGRATION TIME (4002) n khi ngng dao ng. t INTEGRATION TIME (4002) n 1.15 n 1.5 thi gian so vi gi tr trn. nu tn hiu phn hi cha ting n tn s cao, th tng gi tr ca tham s 1303 FILTER AI1 hoc 1306 FILTER AI2 cho n khi ting n c lc t cc tn hiu.

Parameters

ACS550 Users Manual

161

Code Description 4002 INTEGRATION TIME Xc nh thi gian tch hp ca b iu khin PID. Thi gian tch hp l, bi mc nh, thi gian cn thit tng u ra bi gi tr sai lch : gi tr sai lch l hng s v 100%. li = 1. thi gian tch hp ca 1 giy c ngha l thay i 100% l t c trong vng 1 giy. 0.0 = NOT SEL v hiu ha tch hp (I-mt phn ca b iu khin). 0.13600.0 thi gian tch hp (giy). xem 4001 cho phng php iu chnh . B D (P 4001 = 10) C (P 4001 = 1) t P 4002 A = Error B = Error value step C = Controller output with Gain = 1 D = Controller output with Gain = 10 Error 100% Process error value A

4003

DERIVATION TIME Xc nh thi gian dn sut cho b iu khin PID. bn c th thm dn sut ca li ny n b iu khin PID u ra . dn sut l mc gi tr sai lch c thay i. cho v d , nu qu trnh li gi tr thay i tuyn tnh , Dn sut l mt hng s c thm vo u ra b iu khin PID. cc dn sut sai lch c lc vi mt b lc mt cc 1-. Thi gian lin tc ca b lc c xc nh bi tham s 4004 PID DERIV FILTER. 0.010.0 thi gian dn sut (giy).

0% PID output Gain P 4001

t D-part of controller output

t P 4003 4004 PID DERIV FILTER Xc nh thi gian lc khng i trong mt phn li dn sut ca u ra b iu khin PID. trc khi c b sung vo u ra b iu khin PID , li dn sut c lc vi b lc mt cc. tng thi gian lc phng cho li dn sut, gim ting n . 0.010.0 thi gian lc khng i (giy). 4005 ERROR VALUE INV Chn bnh thng hoc ngc gia tn hiu phn hi v tc bin tn . 0 = NO bnh thng, gim tn hiu phn hi lm tng tc bin tn. Error = Ref - Fbk 1 = YES ngc, gim tn hiu phn hi lm tng tc bin tn. Error = Fbk - Ref 4006 UNITS Chn n v cho b iu khin PID gi tr thc t. (PID1 tham s 0128, 0130 v 0132). xem tham s 3405 cho danh sch cc n v c sn. 4007 UNIT SCALE Xc nh v tr im thp phn b iu khin PID gi tr thc t. nhp v tr im thp phn t bn phi ca mc . xem bng cho v d s dng pi (3.14159). 4007 value 0 1 2 3 Entry 0003 0031 0314 3142 Display 3 3.1 3.14 3.142

Parameters

162

ACS550 Users Manual

Code Description 4008 0% VALUE Xc nh (cng vi cc thng s tip theo) p dng t l cho b iu khin PID tn hiu thc t (PID1 tham s 0128, 0130 v 0132). n v l t l xc nh bi tham s 4006 v 4007. 4009 100% VALUE Xc nh (cng vi cc thng s tip theo) p dng t l n b iu khin PID tn hiu thc t. n v l t l xc nh bi tham s 4006 v 4007. P 4008 n v (P4006) T l (P4007) P 4009

+1000.0%

-1000.0% 4010 SET POINT SEL

0%

100% T l bn trong (%)

Xc nh tn hiu ngun tham chiu cho b iu khin PID . thng s khng c gi tr khi PID iu chnh l bi-passed (xem 8121 REG BYPASS CTRL). 0 = KEYPAD tham chiu c cung cp t bng iu khin . 1 = AI1 u vo tng t 1 cung cp tham chiu. 2 = AI2 u vo tng t 2 cung cp tham chiu. 8 = COMM Fieldbus cung cp tham chiu. 9 = COMM+AI1 xc nh fieldbus v u vo tng t 1 (AI1) kt hp nh l ngun tham chiu. Xem iu chnh u vo tng t di y. 10 = COMM*AI1 xc nh fieldbus v u vo tng t 1 (AI1) kt hp nh l ngun tham chiu. Xem iu chnh u vo tng t di y . 11 = DI3U,4D(RNC) u vo s, hot ng nh ch chit p kim sot ng c, cung cp tham chiu. DI3 tng tc (U vit tc ca up) DI4 gim tham chiu ( D vit tc ca down). tham s 2205 ACCELER TIME 2 iu khin tham chiu ca tc thay i. R = Stop lnh resets tham chiu n. NC = gi tr tham chiu khng sao chp. 12 = DI3U,4D(NC) tng t nh DI3,4D(RNC) trn, ngoi tr: lnh dng khng thit lp li tham chiu n khng. Lc khi ng li ng c tng tc theo dc, vi tc tng tc , c la chn ,tham chiu c lu tr. 13 = DI5U,6D(NC) tng t nh DI3U,4D(NC) trn, ngoi tr: s dng u vo KTS DI5 v DI6. 14 = AI1+AI2 xc nh mt u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham chiu. xem iu chnh tham chiu u vo tng t di y. 15 = AI1*AI2 xc nh mt u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham chiu. xem iu chnh tham chiu u vo tng t di y. 16 = AI1-AI2 xc nh mt u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham chiu. xem iu chnh tham chiu u vo tng t di y. 17 = AI1/AI2 xc nh mt u vo tng t 1 (AI1) v u vo tng t 2 (AI2) kt hp nh ngun tham chiu. xem iu chnh tham chiu u vo tng t di y. 19 = INTERNAL mt gi tr thit lp khng i s dng tham s 4011 cung cp tham chiu. 20 = PID2OUT xc nh b iu khin PID 2 u ra (tham s 0127 PID 2 OUTPUT) nh l ngun tham chiu.

Parameters

ACS550 Users Manual

163

m t iu chnh tham chiu u vo tng t Gi tr tham chiu 9, 10 v 1417 s dng cng thc trong bng sau. Value setting C+B C*B C-B C/B Calculation of the AI reference C value + (B value - 50% ca gi tr tham chiu) C value (B value / 50% ca gi tr tham chiu) (C value + 50% ca gi tr tham chiu) - B value (C value 50% ca gi tr tham chiu) / B value 120 17 (/) 100 80 60 40 20 0 16 (-) 0 100% B 9, 14 (+) 10, 15 (*)

Trong : C = gi tr tham kho chnh ( = COMM cho cc gi tr 9, 10 v = AI1 cho gi tr 1417) B = iu chnh tham chiu ( = AI1 cho cc gi tr 9, 10 v = AI2 cho cc gi tr 1417). V d : Hnh bn cho thy ng cong tham chiu ngun cho thit lp gi tr 9, 10 v 1417, trong : C = 25%. P 4012 SETPOINT MIN = 0. P 4013 SETPOINT MAX = 0. B dao ng dc theo trc ngang.

4011

INTERNAL SETPNT t mt gi tr khng i s dng cho qu trnh tham kho . n v v t l c xc dnh bi tham s 4006 v 4007.

4012

SETPOINT MIN t gi tr nh nht cho tn hiu ngun tham chiu. xem tham s 4010.

4013

SETPOINT MAX t gi tr ln nht cho tn hiu ngun tham chiu. xem tham s 4010.

4014

FBK SEL Xc nh tn hiu phn hi b iu khin PID (tn hiu thc t). bn c th xc nh mt kt hp ca hai gi tr thc t (ACT1 v ACT2) nh l tn hiu phn hi. s dng tham s 4016 xc nh ngun cho gi tr thc t 1 (ACT1). s dng tham s 4017 xc nh ngun cho gi tr thc t 2 (ACT2). 1 = ACT1 gi tr thc t 1 (ACT1) cung cp tn hiu phn hi . 2 = ACT1-ACT2 ACT1 tr ACT2 cung cp tn hiu phn hi. 3 = ACT1+ACT2 ACT1 cng ACT2 cung cp tn hiu phn hi. 4 = ACT1*ACT2 ACT1 nhn ACT2 cung cp tn hiu phn hi. 5 = ACT1/ACT2 ACT1 chia ACT2 cung cp tn hiu phn hi. 6 = MIN(ACT1,2) nh hn ca ACT1 hoc ACT2 cung cp tn hiu phn hi. 7 = MAX(ACT1,2) ln hn ca ACT1 hoc ACT2 cung cp tn hiu phn hi. 8 = sqrt(ACT1-2) cn bc hai ca gi tr ACT1 tr ACT2 cung cp tn hiu phn hi. 9 = sqA1+sqA2 cn bc hai ca ACT1 cng vi cn bc hai ca ACT2 cung cp tn hiu phn hi. 10 = sqrt(ACT1) cn bc hai ca ACT1 cung cp tn hiu phn hi. 11 = COMM FBK 1 tn hiu 0158 PID COMM VALUE 1 cung cp tn hiu phn hi. 12 = COMM FBK 2 tn hiu 0159 PID COMM VALUE 2 cung cp tn hiu phn hi. 13 = AVE(ACT1,2) t l trung bnh ca ACT1 v ACT2 cung cp tn hiu phn hi.

4015

FBK MULTIPLIER Xc nh mt s nhn thm cho phn hi PID gi tr FBK xc nh bi tham s 4014. c dng ch yu trong cc ng dng tnh s chnh lch p sut khc nhau. 0.000 = NOT SEL tham s ny khng c hiu lc (1.000 s dng nh l h s nhn). -32.76832.767 nhn c p dng cho cc tn hiu xc nh bi tham s 4014 FBK SEL. V d: FBK = nhn A1 A2

Parameters

164

ACS550 Users Manual

Code 4016

Description ACT1 INPUT Xc nh ngun cho tn hiu thc t 1 (ACT1). Xem thm tham s 4018 ACT1 MINIMUM. 1 = AI1 s dng u vo tng t 1 cho ACT1. 2 = AI2 s dng u vo tng t 2 cho ACT1. 3 = CURRENT s dng dng in cho ACT1. 4 = TORQUE s dng momen xon cho ACT1. 5 = POWER s dng cng sut cho ACT1. 6 = COMM ACT 1 s dng gi tr ca tn hiu 0158 PID COMM VALUE 1 cho ACT1. 7 = COMM ACT 2 s dng gi tr ca tn hiu 0159 PID COMM VALUE 2 cho ACT1.

4017

ACT2 INPUT Xc nh ngun cho gi tr thc t 2 (ACT2). Xem thm tham s 4020 ACT2 MINIMUM. 1 = AI1 s dng u vo tng t 1 cho ACT2. 2 = AI2 s dng u vo tng t 2 cho ACT2. 3 = CURRENT s dng dng in cho ACT2. 4 = TORQUE s dng momen xon cho ACT2. 5 = POWER s dng cng sut cho ACT2. 6 = COMM ACT 1 s dng gi tr ca tn hiu 0158 PID COMM VALUE 1 cho ACT2. 7 = COMM ACT 2 s dng gi tr ca tn hiu 0159 PID COMM VALUE 2 cho ACT2.

4018

ACT1 MINIMUM Thit lp gi tr nh nht cho ACT1. t l tn hiu ngun s dng nh gi tr thc t ACT1 (xc nh bi tham s 4016 ACT1 INPUT). Cho tham s 4016 gi tr 6 (COMM ACT 1) v 7 (COMM ACT 2) t l khng c thc hin. Par 4016 1 2 3 4 5 Source Analog input 1 Analog input 2 Current Torque Power Source min. 1301 MINIMUM AI1 1304 MINIMUM AI2 0 -2 nominal torque -2 nominal power Source max. 1302 MAXIMUM AI1 1305 MAXIMUM AI2 2 nominal current 2 nominal torque 2 nominal power

ACT1

(%)

P 4019

P 4018 Source min. Source max. Source signal


ACT1

(%)

xem hnh: A= bnh thng; B = o ngc (ACT1 MINIMUM > ACT1 MAXIMUM) 4019 ACT1 MAXIMUM t gi tr ln nht cho ACT1. xem 4018 ACT1 MINIMUM. 4020 ACT2 MINIMUM t gi tr nh nht cho ACT2. xem 4018 ACT1 MINIMUM. 4021 ACT2 MAXIMUM t gi tr ln nht cho ACT2. xem 4018 ACT1 MINIMUM. 4022 SLEEP SELECTION

P 4018

P 4019 Source min. Source max.

Source signal

Xc nh kim sot cho chc nng ng PID. 0 = NOT SEL v hiu ha kim sot chc nng ng PID. 1 = DI1 xc nh u vo s DI1 nh kim sot chc nng ng PID . kch hot u vo s kch hot chc nng ng. kh kch hot u vo s khi phc kim sot PID . 26 = DI2DI6 xc nh u vo s DI2DI6 nh kim sot chc nng ng PID. xem DI1 trn. 7 = INTERNAL xc nh u ra rpm/tn s , quy trnh tham chiu v quy trnh gi tr thc t nh kim sot chc nng ng PID. Tham chiu n tham s 4025 WAKE-UP DEV v 4023 PID SLEEP LEVEL. -1 = DI1(INV) xc nh ngc u vo s DI1 nh kim sot chc nng ng PID. kh kch hot u vo s kch hot chc nng ng. kch hot u vo s khi phc kim sot PID . -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot chc nng ng PID. xem DI1(INV) trn.

Parameters

ACS550 Users Manual

165

Code Description 4023 PID SLEEP LEVEL Thit lp tc / tn s ng c cho php chc nng ng PID tc / tn s ng c di mc ny , cho khong thi gian t nht 4024 PID SLEEP DELAY cho php chc nng ng PID (bin tn dng li). yu cu 4022 = 7 (INTERNAL). xem hnh: A = PID cp u ra; B = PID qu trnh thc t. 4024 PID SLEEP DELAY Thit lp thi gian tr hon cho chc nng ng PID tc / tn s ng c thp 4023 PID SLEEP LEVEL cho khong thi gian t nht cho php chc nng ng PID (bin tn dng li). xem 4023 PID SLEEP LEVEL trn. 4025 WAKE-UP DEV Xc nh lch nh thc lch t im t ln hn gi tr ny cho khong thi gian t nht 4026 WAKE-UP DELAY, khi ng li b iu khin PID . tham s 4006 v 4007 xc nh n v v t l. tham s 4005 = 0, cp tnh dy = im t lch tnh dy. tham s 4005 = 1, cp tnh dy = im t + lch tnh dy. Cp tnh dy c th trn hoc di im t. Xem hnh: C = Cp tnh dy khi tham s 4005 = 1 D = Cp tnh dy khi tham s 4005 = 0 E = thng tin phn hi l trn cp tnh dy v ko di lu hn 4026 WAKE-UP DELAY PID chc nng tnh dy. F = thng tin phn hi l di cp tnh dy v ko di lu hn 4026 WAKE-UP DELAY PID chc nng tnh dy. 4026 WAKE-UP DELAY Xc nh s tnh dy tr mt lch t mt im t ln hn 4025 WAKE-UP DEV, cho khong thi gian ny t nht, khi ng li b iu khin PID. Setpoint P 4025 t Stop Start t < P 4024 t > P 4024 P 4023 t B P 4026 A

P 4025 Setpoint P 4025

}4005 = 1

}4005 = 0
D t

E C P 4025 Setpoint P 4025 P 4026 D P 4026 F

Parameters

166

ACS550 Users Manual

Code Description 4027 PID 1 PARAM SET Qu trnh PID (PID1) c hai b ring bit ca cc thng s, PID t 1 v PID t 2. PID t 1 s dng b tham s 40014026. PID t 2 s dng b tham s 41014126. PID 1 PARAM SET xc nh nhng thit lp c chn. 0 = SET 1 PID Set 1 (cc tham s 40014026) l hot ng . 1 = DI1 xc nh u vo s DI1 nh kim sot cho chn PID Set. kch hot u vo s chn PID t 2. kh kch hot u vo s chn PID t 1. 26 = DI2DI6 xc nh u vo s DI2DI6 nh kim sot cho chn PID Set. xem DI1 trn. 7 = SET 2 PID Set 2 (tham s 41014126) l hot ng. 811 = TIMED FUNC 14 xc nh chc nng hn gi nh kim sot cho chn PID Set (chc nng hn gi kh kch hot = PID Set 1; chc nng hn gi kch hot = PID Set 2) xem nhm 36: TIMED FUNCTIONS. 12 = 2-ZONE MIN bin tn tnh ton s khc nhau gia im t 1 v phn hi 1 cng nh im t 2 v phn hi 2. bin tn s kim sot khu vc (v chn thit lp) m c s khc bit. mt s dng khc (im t cao hn thng tin phn hi) lun lun ln hn s m khc. Gi gi tr phn hi ti hoc trn im t . b iu khin khng phn ng n trng thi phn hi trn im t nu mt thng tin phn hi gn im t ca n. 13 = 2-ZONE MAX bin tn tnh ton s khc nhau gia im t 1 v phn hi 1 cng nh im t 2 v phn hi 2. bin tn s kim sot khu vc (v chn thit lp) m c s khc bit. mt s m khc (im t thp hn thng tin phn hi) lun lun nh hn s dng khc. Gi gi tr phn hi ti hoc di im t. b iu khin khng phn ng n trng thi phn hi di im t nu mt thng tin phn hi gn im t ca n. 14 = 2-ZONE AVE bin tn tnh ton s khc nhau gia im t 1 v phn hi 1 cng nh im t 2 v phn hi 2. Ngoi ra, n tnh ton t l trung bnh ca lch v s dng n kim sot khu vc 1. do mt phn hi l gi trn im t v gi n nh di im t. -1 = DI1(INV) xc nh ngc u vo s DI1 nh kim sot cho chn PID Set. kch hot u o s chn PID Set 1. kh kch hot u vo s chn PID Set 2. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot cho chn PID Set. xem DI1(INV) trn.

Parameters

ACS550 Users Manual

167

nhm 41: PROCESS PID SET 2 Tham s ca nhm ny thuc v PID tham s set 2. cc hot ng ca cc tham s 41014126 l tng t vi set 1 tham s 40014026. PID tham s set 2 c th chn bi tham s 4027 PID 1 PARAM SET.
Code 4101 4126 Description xem 4001 4026

Parameters

168

ACS550 Users Manual

nhm 42: EXT / TRIM PID Nhm ny xc nh cc tham s s dng cho b iu khin PID th hai (PID2), c s dng cho External / Trimming PID. Hot ng ca tham s 42014221 l tng t vi qu trnh PID set 1 (PID1) tham s 40014021.
Code Description 4201 4221 4228 xem 4001 4021

ACTIVATE Xc nh ngun cho php chc nng PID bn ngoi. yu cu 4230 TRIM MODE = 0 (NOT SEL). 0 = NOT SEL v hiu ha kim sot PID bn ngoi. 1 = DI1 xc nh u vo s DI1 nh kim sot cho php kim sot PID bn ngoi. kch hot u vo s cho php kim sot PID bn ngoi. kh kch hot u vo s v hiu ha kim sot PID bn ngoi. 26 = DI2DI6 xc nh u vo s DI2DI6 nh kim sot cho php kim sot PID bn ngoi. xem DI1 trn. 7 = DRIVE RUN xc nh lnh khi ng nh kim sot cho php kim sot PID bn ngoi. kch hot lnh khi ng (bin tn chy) cho php kim sot PID bn ngoi. 8 = ON xc nh ngun in-on nh kim sot cho php kim sot PID bn ngoi. cp ngun in vo bin tn cho php kim sot PID bn ngoi. 912 = TIMED FUNC 14 xc nh chc nng hn gi nh kim sot cho php kim sot PID bn ngoi (chc nng hn gi kch hot cho php kim sot PID bn ngoi). xem nhm 36: TIMED FUNCTIONS. -1 = DI1(INV) xc nh ngc u vo s DI1 nh kim sot cho php kim sot PID bn ngoi. kch hot u vo s v hiu ha kim sot PID bn ngoi. kh kch hot u vo s cho php kim sot PID bn ngoi. -2-6 = DI2(INV)DI6(INV) xc nh ngc u vo s DI2DI6 nh kim sot cho php kim sot PID bn ngoi. xem DI1(INV) trn.

4229

OFFSET Xc nh lch cho u ra PID. khi PID l hot ng, trng thi u ra t gi tr ny . khi PID khng hot ng, u ra resets n gi tr ny. tham s l hot ng khi 4230 TRIM MODE = 0 (ch trim khng hot ng ).

4230

TRIM MODE Chn loi ca vi chnh, nu c. S dng vi chnh n c th kt hp mt h s n tham chiu bin tn. 0 = NOT SEL v hiu ha chc nng vi chnh. 1 = PROPORTIONAL thm mt s yu t vi chnh t l thun vi tham chiu rpm/Hz . 2 = DIRECT thm mt s yu t vi chnh da trn gii hn ti a ca kim sot vng lp .

4231

TRIM SCALE Xc nh nhn (nh phn trm, cng hoc tr) c s dng ch vi chnh.

Parameters

ACS550 Users Manual

169

Code Description 4232 CORRECTION SRC Xc nh tham chiu tinh chnh cho ngun sa cha. 1 = PID2REF s dng tng thch REF MAX (SWITCH A OR B): 1105 REF1 MAX khi REF1 ang hot ng (A). 1108 REF2 MAX khi REF2 ang hot ng (B). 2 = PID2OUTPUT s dng tc hoc tn s c lp ln nht (Switch C): 2002 MAXIMUM SPEED nu 9904 MOTOR CTRL MODE = 1 (VECTOR:SPEED) hoc 2 (VECTOR:TORQ). 2008 MAXIMUM FREQ nu 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ). Ramped ref Add Trimmed ref Switch Ext ref 1 max (A) Ext ref 2 max (B) Abs max speed/ freq (C) Select (par. 4230) off proportional direct Select (par. 4232) Trimming PID2 ref PID2 ref PID 2 Trimming PID2 out Trim scale Mul. X Mul. X +

Parameters

170

ACS550 Users Manual

nhm 50: ENCODER Nhm ny xc nh thit lp cho s dng b m ha xung : thit lp s lng xung m ha trn mi vng quay. cho php hot ng b m ha. xc nh lm th no thit lp li gc c kh v my m vng quay . Xem thm Users Manual for Pulse Encoder Interface Module OTAC-01 [3AUA0000001938 (English)].
Code Description 5001 5002 PULSE NR Thit lp s lng xung c cung cp bi b m ha ty chn cho mi vng quay ton b trc ng c (ppr). ENCODER ENABLE Cho php/v hiu ha mt ty chn b m ha. 0 = DISABLE bin tn s dng tc phn hi t bn trong m hnh ng c (p dng cho bt k thit lp ca tham s 9904 MOTOR CTRL MODE). 1 = ENABLE bin tn s dng thng tin phn hi t ty chn b m ha xung. Chc nng ny i hi giao din Pulse Encoder Module (OTAC-01) v mt b m ha. Hot ng ph thuc vo thit lp ca tham s 9904 MOTOR CTRL MODE: 9904 = 1 (VECTOR:SPEED): b m ha cung cp thng tin phn hi ci thin tc v ci thin chnh xc momen xon thp . 9904 = 2 (VECTOR:TORQ): b m ha cung cp thng tin phn hi ci thin tc v ci thin chnh xc momen xon thp. 9904 = 3 (SCALAR:SPEED): b m ha cung cp tc phn hi. (y khng phi l ng tc vng lp. Tuy nhin, bng cch s dng tham s 2608 SLIP COMP RATIO v b m ha tc ci thin n nh trng thi .) 5003 ENCODER FAULT Xc nh bin tn hot ng nu li c pht hin trong giao tip gia b m ha v giao din module b m ha , hoc gia module v bin tn . 1 = FAULT bin tn pht sinh li ENCODER ERR, v ng c dng theo qun tnh . 2 = ALARM bin tn pht sinh bo ng ENCODER ERR v hot ng nh tham s 5002 ENCODER ENABLE = 0 (DISABLE), c ngha l, tc phn hi c xc nh t bn trong model ng c. 5010 Z PLS ENABLE Cho php /v hiu ha s dng ca b m ha xung Z- xc nh v tr khng ca trc ng c. Khi cho php, mt xung Zu vo reset tham s 0146 MECH ANGLE n khng xc nh v tr khng ca trc. chc nng ny yu cu b m ha cung cp tn hiu xung Z-. 0 = DISABLE Z- u vo xung l khng c hoc b qua nu c. 1 = ENABLE A Z u vo xung reset tham s 0146 MECH ANGLE n khng. 5011 POSITION RESET Resets v tr phn hi b m ha. tham s l t xa. 0 = DISABLE khng hot ng. 1 = ENABLE Resets v tr phn hi b m ha. Tham s reset xc nh trn trng thi ca tham s 5010 Z PLS ENABLE: 5010 = 0 (DISABLE) Reset p dng n cc tham s 0147 MECH REVS v 0146 MECH ANGLE. 5010 = 1 (ENABLE) Reset p dng thm tham s 0147 MECH REVS.

Parameters

ACS550 Users Manual

171

nhm 51: EXT COMM MODULE Nhm ny xc nh cc bin cho b chuyn i fieldbus (FBA) module truyn thng . bit thm chi tit v cc tham s ny, hy tham kho sch hng dn s dng cung cp vi cc module FBA.
Code Description 5101 FBA TYPE Hin th kiu ca kt ni b chuyn i fieldbus module. 0 = NOT DEFINED Module l khng tm thy, hoc kt ni khng ng, hoc tham s 9802 khng c t n 4 (EXT FBA). 1 = PROFIBUS-DP 16 = INTERBUS 21 = LONWORKS 32 = CANopen 37 = DEVICENET 64 = MODBUS PLUS 101 = CONTROLNET 128 = ETHERNET 5102 FB PAR 2FB PAR 26 Tham chiu n t liu truyn thng module cho thm thng tin v cc tham s ny. 5126 5127 FBA PAR REFRESH Xc nhn bt k thay i thng s ci t fieldbus. 0 = DONE khng lm mi. 1 = REFRESH lm mi. sau khi lm mi, gi tr t ng phc hi n DONE. 5128 FILE CPI FW REV Hin th phin bn vi chng trnh CPI ca cu hnh tp tin b chuyn i fieldbus ca bin tn. nh dng l xyz trong : x = phin bn chnh y = phin bn nh z = phin bn s V d: 107 = phin bn 1.07 5129 FILE CONFIG ID Hin th phin bn ca cu hnh nh dng tp tin b chuyn i fieldbus module ca bin tn. thng tin cu hnh tp tin l ph thuc vo chng trnh ng dng ca bin tn. 5130 FILE CONFIG REV Bao gm phin bn ca cu hnh nh dng tp tin b chuyn i fieldbus module ca bin tn. V d: 1 = phin bn 1 5131 FBA STATUS Cha trng thi ca b chuyn i module. 0 = IDLE b chuyn i khng c cu hnh. 1 = EXECUT INIT b chuyn i c khi to. 2 = TIME OUT mt thi gian ch xy ra trong giao tip gia b chuyn i v bin tn . 3 = CONFIG ERROR cu hnh b chuyn i b li. m sa i ca phin bn vi chng trnh b chuyn i CPI l c hn yu cu ca phin bn vi chng trnh CPI xc nh trong bin tn l tp tin cu hnh (tham s 5132 < 5128). 4 = OFF-LINE b chuyn i l off-line. 5 = ON-LINE b chuyn i l on-line. 6 = RESET b chuyn i l thc hin thit lp li phn cng. 5132 FBA CPI FW REV C cc phn bn ca module l chng trnh CPI. nh dng l xyz trong : x = phin bn chnh y = phin bn nh z = phin bn s Example: 107 = revision 1.07 5133 FBA APPL FW REV C cc phin bn ca module l chng trnh ng dng. nh dng l xyz (xem tham s 5132).

Parameters

172

ACS550 Users Manual

nhm 52: PANEL COMM Nhm ny xc nh thit lp truyn thng cho cng truyn bng iu khin trn bin tn. Thng thng, khi s dng bng iu khin cung cp, khng cn phi thay i thit lp trong nhm. Trong nhm ny, tham s sa i lm nh hng n ln m in tip theo.
Code 5201 Description STATION ID Xc nh a ch ca bin tn. hai n v cng a ch khng c php trn mng . phm vi : 1247 5202 BAUD RATE Xc nh tc truyn thng ca bin tn trong kbits trn giy (kb/s). 9.6 kb/s 19.2 kb/s 38.4 kb/s 57.6 kb/s 115.2 kb/s 5203 PARITY Thit lp k t nh dng c s dng vi truyn thng bng iu khin . 0 = 8 NONE 1 khng tng ng, mt dng bit. 1 = 8 NONE 2 khng tng ng, hai dng bits. 2 = 8 EVEN 1 chn, mt dng bit . 3 = 8 ODD 1 l, mt dng bit. 5204 OK MESSAGES Cha mt s ca tin nhn hp l Modbus nhn c bi bin tn. trong thi gian hot ng bnh thng, gi tr b m tng lin tc . 5205 PARITY ERRORS Cha mt s ca k t vi li chn l l nhn c t bus. Cho b m cao, kim tra : ci t chn l ca thit b kt ni trn bus h khng khc bit . ting n in t ca mi trng xung quanh mc ting n cao to ra cc li. 5206 FRAME ERRORS C cha mt s ca k t vi mt khung li m bus nhn c. Cho b m cao, kim tra: thit lp tc giao tip ca kt ni thit b trn bus h khng khc bit. ting n in t ca mi trng xung quanh mc ting n cao to ra cc li.. 5207 BUFFER OVERRUNS C cha mt s ca k t nhn c m khng th c t trong b m. chiu di tin nhn di nht cho bin tn l 128 bytes. nhn c tin nhn vt qu 128 bytes trn b m. Cc k t vt qu c m. 5208 CRC ERRORS Cha mt s ca tin nhn vi mt li CRC m bin tn nhn c. Cho b m cao, kim tra : ting n in t ca mi trng xung quanh mc ting n cao to ra cc li. CRC tnh cc li c th xy ra .

Parameters

ACS550 Users Manual

173

nhm 53: EFB PROTOCOL Nhm ny xc nh thit lp s dng cc bin cho t vo giao thc truyn thng fieldbus (EFB) .giao thc tiu chun EFB trong ACS550 l Modbus. Xem chng Embedded fieldbus trang 189.
Code Description 5301 EFB PROTOCOL ID Bao gm xc nh v sa i chng trnh ca giao thc. nh dng: XXYY, trong xx = giao thc ID, v YY = sa i chng trnh . 5302 EFB STATION ID Xc nh im a ch ca lin kt RS485 . nt a ch trn mi n v l duy nht . 5303 EFB BAUD RATE Xc nh tc truyn thng ca kin kt RS485 trong kbits trn giy (kb/s). 1.2 kb/s 2.4 kb/s 4.8 kb/s 9.6 kb/s 19.2 kb/s 38.4 kb/s 57.6 kb/s 76.8 kb/s 5304 EFB PARITY Xc nh d liu di ,chn l v dng bits c s dng vi lin kt truyn thng RS485. thit lp tng t phi c s dng trong tt c trng thi trn ng truyn. 0 = 8 NONE 1 8 data bit , khng tng ng,mt dng bit. 1 = 8 NONE 2 8 data bit , khng tng ng,hai dng bit. 2 = 8 EVEN 1 8 data bit , chn, mt dng bit. 3 = 8 ODD 1 8 data bit , l, mt dng bit. 5305 EFB CTRL PROFILE Chn thng tin truyn thng c s dng bi giao thc EFB. 0 = ABB DRV LIM hot ng ca Control/Status Words ph hp vi ABB Drives Profile, nh s dng trong ACS400. 1 = DCU PROFILE hot ng ca Control/Status Words ph hp vi 32-bit DCU Profile. 2 = ABB DRV FULL hot ng ca Control/Status Words ph hp vi ABB Drives Profile, nh s dng trong ACS600/800. 5306 EFB OK MESSAGES Cha mt s ca tin nhn hp l xc nh bi bin tn . trong thi gian hot ng, b m tng gi tr lin tc . 5307 EFB CRC ERRORS Cha mt s ca tin nhn vi mt li CRC nhn c bi bin tn. Cho b m cao, kim tra: ting n in t ca mi trng xung quanh mc ting n cao to ra cc li. CRC tnh cc li c th xy ra. 5308 5309 EFB UART ERRORS Cha mt s ca tin nhn vi mt khung li nhn c t bin tn. EFB STATUS Cha cc trng thi ca giao thc EFB . 0 = IDLE EFB giao thc c cu hnh, nhng khng nhn c bt k tin nhn no. 1 = EXECUT INIT EFB giao thc c khi to . 2 = TIME OUT mt thi gian ch xy ra trong giao tip gia mng chnh v giao thc EFB . 3 = CONFIG ERROR EFB giao thc c li cu hnh. 4 = OFF-LINE EFB giao thc ang nhn tin nhn m khng gi n bin tn. 5 = ON-LINE EFB giao thc ang nhn tin nhn c gi n bin tn. 6 = RESET EFB giao thc ang thc hin reset li phn cng. 7 = LISTEN ONLY EFB giao thc l trong ch ch nghe. 5310 EFB PAR 10 Ch nh cc tham s nh x n Modbus Register 40005.

Parameters

174

ACS550 Users Manual

Code Description 5311 5312 5313 5314 5315 5316 5317 5318 EFB PAR 11 Ch nh cc tham s nh x n Modbus Register 40006. EFB PAR 12 Ch nh cc tham s nh x n Modbus Register 40007. EFB PAR 13 Ch nh cc tham s nh x n Modbus Register 40008. EFB PAR 14 Ch nh cc tham s nh x n Modbus Register 40009. EFB PAR 15 Ch nh cc tham s nh x n Modbus Register 40010. EFB PAR 16 Ch nh cc tham s nh x n Modbus Register 40011. EFB PAR 17 Ch nh cc tham s nh x n Modbus Register 40012. EFB PAR 18 Modbus: thit lp tr thm trong milli giy trc khi ACS550 bt u truyn ti p ng yu cu tng th . 5319 5320 EFB PAR 19 ABB Drives profile (ABB DRV LIM hoc ABB DRV FULL) Control Word. Ch c bng sao ca Fieldbus Control Word. EFB PAR 20 ABB Drives profile (ABB DRV LIM hoc ABB DRV FULL) Status Word. Ch c bng sao ca Fieldbus Status Word.

Parameters

ACS550 Users Manual

175

nhm 81: PFC CONTROL Nhm ny xc nh ch kim sot BM-QUT (PFC) ca phng thc hot ng. Tnh nng chnh ca kim sot PFC l : ACS550 iu khin ng c ca bm s. 1, thay i tc ng c kim sot cng sut my bm. ng c ny l tc quy nh ca ng c. kt ni trc tip ngun in ng c ca bm s . 2 v bm s .3, v,v. ACS550 chuyn mch bm s. 2 (v sau bm s. 3, v,v.) on v off khi cn thit. Cc ng c l ng c ph . ACS550 PID kim sot s dng hai tn hiu: mt qu trnh tham chiu v mt gi tr phn hi thc t. b iu khin PID iu chnh tc (tn s) ca bm u tin nh gi tr thc t sau qu trnh tham chiu . khi yu cu (xc nh bi qu trnh tham chiu) vt qu cng sut ng c (ngi dng xc nh nh l mt gii hn tn s), b diu khin PFC t ng khi ng my bm ph . PFC cng lm gim tc ca bm u tin tnh n cng sut bm ph b sung n tng cng sut. sau ,nh trc y, b iu khin PID iu chnh tc (tn s) ca bm th nht nh gi tr thc t sau qu trnh tham chiu. nu yu cu tip tc tng, PFC cho bit thm my bm b sung ph tr, s dng cng quy trnh . khi yu cu gim xung, nh vy tc my bm u tin gim xung di tc gii hn nh nht (ngi dng xc nh bi mt gii hn tn s), b iu khin PFC t ng dng mt my bm ph tr. PFC cng tng tc ca my bm u tin tnh n cng sut b thiu ca bm ph tr . mt chc nng kha lin ng (khi kch hot) xc nh ngt kt ni ng c (u ra ca thit b ph), v iu khin PFC b qua sn sng ng c tip theo trong chui. mt chc nng t ng thay i (khi kch hot v vi cc thit b chuyn mch ph hp) cn bng thi gian tc dng gia cc ng c bm. T ng thay i nh k gia s v tr ca tng ng c trong t quay tc , tr thnh ng c ph mi nht , cc ng c ph u tin tr thnh tc iu chnh ng c v . v .
Code Description 8103 REFERENCE STEP 1 Thit lp gi tr phn trm c thm vo qu trnh tham chiu. thm vo ch khi c t nht mt ng c ph (tc khng i) ang chy. mc nh gi tr l 0%. V d : ACS550 hot ng ba bm song song m duy tr p lc nc trong mt ng. 4011 INTERNAL SETPNT thit lp mt tham chiu p lc lin tc kim sot p sut trong ng ng . tc quy nh bm hot ng mt mnh mc tiu th t nc . lng nc tiu th tng, tc khng i bm u tin hot ng, sau , bm th hai. khi tng lu lng, p sut u ra cui ng ng so vi p sut o u vo kt thc khi bc ng c ph tng lu lng, iu chnh chnh xc tham chiu di y kt hp cht ch hn p sut u ra. khi bm ph u tin hot ng ,tng cng tham chiu vi tham s 8103 REFERENCE STEP 1. khi hai bm ph hot ng, tng cng tham chiu vi tham s 8103 REFERENCE STEP 1 + tham s 8104 REFERENCE STEP 2. khi ba bm ph hot ng, tng cng tham chiu vi tham s 8103 REFERENCE STEP 1 + tham s 8104 REFERENCE STEP 2 + tham s 8105 REFERENCE STEP 3.

Parameters

176

ACS550 Users Manual

Code Description 8104 REFERENCE STEP 2 Thit lp gi tr phn trm c thm vo qu trnh tham chiu. ch p dng khi c t nht hai ng c ph (tc khng i) ang chy . xem tham s 8103 REFERENCE STEP 1. 8105 REFERENCE STEP 3 Thit lp gi tr phn trm c thm vo qu trnh tham chiu. ch p dng khi c t nht ba ng c ph (tc khng i) ang chy. xem tham s 8103 REFERENCE STEP 1. 8109 START FREQ 1 Thit lp gii hn tn s s dng khi ng ng c ph u tin. ng c ph u tin khi ng nu: khng c ng c ph no ang chy . f (Hz) ACS550 u ra tn s vt qu gii hn : P 8115 8109 + 1 Hz. tn s u ra vn trn trn gii hn lm nh fMAX (8109 - 1 Hz) cho thi gian it nht: 8115 AUX MOT START D. (P 8109)+1 Sau khi ng c ph th nht khi ng : P 8109 u ra tn s gim bi gi tr = A (8109 START FREQ 1) - (8112 LOW FREQ 1). P 8112 trong thc t , u ra ca ng c gim xung tc thp fMIN b cho u vo t ng c ph . xem hnh , trong : A = (8109 START FREQ 1) - (8112 LOW FREQ 1) B = tn s u ra tng trong thi gian khi ng tr . C = biu hin th trng thi chy ng c ph nh tng tn s (1 = On). Ch : 8109 START FREQ 1 gi tr phi c gia : 8112 LOW FREQ 1 (2008 MAXIMUM FREQ) -1. 8110 START FREQ 2 Thit lp gii hn tn s s dng khi ng ng c ph th hai . xem 8109 START FREQ 1 cho m t y ca hot ng. ng c ph th hai khi ng nu : ng c ph mt ang chy. ACS550 tn s u ra vt qu gii hn: 8110 + 1. tn s u ra vn trn trn gii hn lm nh (8110 - 1 Hz) cho thi gian t nht: 8115 AUX MOT START D. 8111 START FREQ 3 Thit lp gii hn tn s s dng khi ng ng c ph th ba. xem 8109 START FREQ 1 cho m t y ca hot ng. ng c ph th ba khi ng nu: ng c ph th hai ang chy. ACS550 tn s u ra vt qu gii hn: 8111 + 1 Hz. tn s u ra vn trn trn gii hn lm nh (8111 - 1 Hz) cho thi gian t nht: 8115 AUX MOT START D.

BA t

C 1 0 t

Parameters

ACS550 Users Manual

177

Code Description 8112 LOW FREQ 1 Thit lp gii hn tn s c s dng dng ng c ph u tin. ng c ph u tin dng li nu : ch c mt ng c ph (u tin) ang chy . f (Hz) ACS550 tn s u ra xung thp di gii hn: 8112 - 1. tn s u ra vn nm di gii hn lm nh P 8109 (8112 + 1 Hz) cho thi gian t nht: 8116 AUX MOT STOP D. fMAX sau khi ng c ph th nht dng : A tn s u ra tng bi gi tr = P 8112 (8109 START FREQ 1) - (8112 LOW FREQ 1). (P 8112)-1 trong thc t , u ra tc ng c tng ln b cho fMIN s mt ca ng c ph . xem hnh ,trong : A = (8109 START FREQ 1) - (8112 LOW FREQ 1) B = tn s u ra gim trong thi gian dng tr . C = biu hin th trng thi chy ng c ph nh gim tn s C (1 = On). 1 ng dn mu xm = hin th tr nu thi gian b o ngc, ng dn v pha sau l khng ging nhau . bit thm chi tit ng dn cho khi ng, 0 xem biu ti 8109 START FREQ 1. Ch : 8112 LOW FREQ 1 gi tr phi c gia : (2007 MINIMUM FREQ) +1. 8109 START FREQ 1 8113 LOW FREQ 2 Thit lp gii hn tn s c s dng dng ng c ph th hai . xem 8112 LOW FREQ 1 cho m t y ca hot ng. ng c ph th hai dng nu: hai ng c ph ang chy . ACS550 tn s u ra thp di gii hn : 8113 - 1. tn s u ra vn di gii hn lm nh (8113 + 1 Hz) cho thi gian t nht: 8116 AUX MOT STOP D. 8114 LOW FREQ 3 Thit lp gii hn tn s c s dng dng ng c ph th ba . xem 8112 LOW FREQ 1 cho m t y ca hot ng . ng c ph th ba dng nu: ba ng c ph ang chy. ACS550 tn s u ra thp di gii hn: 8114 - 1. tn s u ra vn di gii hn lm nh (8114 + 1 Hz) cho thi gian t nht: 8116 AUX MOT STOP D. 8115 AUX MOT START D Thit lp khi ng tr cho cc ng c ph . tn s u ra phi trn gii hn tn s cao (tham s 8109, 8110, hoc 8111) cho khong thi gian ny Trc khi cc ng c ph khi ng . xem 8109 START FREQ 1 cho m t y ca hot ng. 8116 AUX MOT STOP D Thit lp dng tr cho cc ng c ph. tn s u ra phi di gii hn tn s thp (tham s 8112, 8113, or 8114) cho khong thi gian ny trc khi cc ng c ph dng. xem 8112 LOW FREQ 1 cho m t y ca hot ng. P 8116

A t

Parameters

178

ACS550 Users Manual

Code Description 8117 NR OF AUX MOT Thit lp s ca ng c ph . mi ng c ph i hi mt u ra relay, m bin tn s dng gi tn hiu khi ng/dng . chc nng t ng thay i, nu c s dng, yu cu b sung u ra relay cho iu chnh tc ng c. di y m t thit lp cc yu cu ca u ra relay . Relay outputs Nh ni trn, mi ng c ph i hi mt u ra relay, m bin tn s dng gi tn hiu khi ng/dng. Di y m t lm th no bin tn theo di ng c v relay . ACS550 cung cp u ra relay RO1RO3. mt module u ra s bn ngoi c th c thm vo cung cp u ra relay RO4RO6. tham s xc nh 14011403 v 14101412, tng ng, lm th no relays RO1RO6 c s dng gi tr tham s 31 PFC xc nh cc relay c s dng cho PFC. ACS550 quy nh ng c ph n relay theo th t tng dn. Nu chc nng t ng thay i b v hiu ha , ng c ph u tin c kt ni n relay u tin vi mt tham s ci t = 31 PFC, v nh vy . nu chc nng t ng thay i c s dng, n nh xoay vng. Ban u , tc ng c n nh c kt ni n relay u tin vi tham s ci t = 31 PFC, ng c ph u tin l mt kt ni n relay th hai vi tham s ci t = 31 PFC, v so on. Relay logic
ACS550 ACS550

Ch PFC tiu chun

PFC vi ch t ng thay i

ng c ph th t c c s dng cng mt bc tham chiu, tn s thp v gi tr tn s khi ng nh ng c ph th ba .

Parameters

ACS550 Users Manual

179

Code

Description bng di y cho thy ACS550 PFC n nh ng c cho mt s ci t in hnh trong Relay Output cc tham s (14011403 v 14101412), ni cc thit lp l khc =31 (PFC), hoc =X (bt c nhng 31), v chc nng t ng thay i b v hiu ha (8118 AUTOCHNG INTERV = 0). Parameter setting ACS550 Relay assignment 1 1 1 1 1 1 8 Autochange disabled 4 4 4 4 4 4 1 RO1 RO2 RO3 RO4 RO5 0 0 0 1 1 1 1 1 2 3 0 1 2 7 31 X X X X X 1 Aux. X X X X 31 31 X X X X 2 Aux. Aux. X X X 31 31 31 X X X 3 Aux. Aux. Aux. X X X 31 31 X X X 2 X Aux. Aux. X X X X X 31 X 31 2 X X X Aux. X 31 31 X X X X 1* Aux. Aux. X X X * = mt u ra relay b sung cho PFC l s dng. mt ng c l trong ng khi khc l quay .

RO6

X X X X Aux. X

bng di y cho thy ACS550 PFC n nh ng c cho mt s ci t in hnh trong Relay Output Cc tham s (14011403 v 14101412), ni cc thit lp l khc =31 (PFC), hoc =X (bt c nhng 31), v Chc nng t ng thay i l cho php (8118 AUTOCHNG INTERV = gi tr l > 0). Parameter setting ACS550 Relay assignment 1 1 1 1 1 1 8 Autochange enabled 4 4 4 4 4 4 1 RO1 RO2 RO3 RO4 RO5 RO6 0 0 0 1 1 1 1 1 2 3 0 1 2 7 31 31 X X X X 1 PFC PFC X X X X 31 31 31 X X X 2 PFC PFC PFC X X X X 31 31 X X X 1 X PFC PFC X X X X X X 31 X 31 1 X X X PFC X PFC 31 31 X X X X 0** PFC PFC X X X X ** = khng ng c ph, nhng chc nng t ng thay i l s dng. s vn hnh Nh kim sot PID-tiu chun. 8118 AUTOCHNG INTERV Kim sot hot ng ca chc nng Autochange v thit lp khong cch gia cc thay i. khong thi gian Autochange ch p dng cho thi im khi ng c ang chy tc n nh . xem tham s 8119 AUTOCHNG LEVEL cho mt tng quan v chc nng Autochange. bin tn lun lun dng theo qun tnh khi t ng thay i c thc hin. Autochange cho php yu cu tham s 8120 INTERLOCKS = gi tr > 0. -0.1 = TEST MODE khong lc c gi tr 3648 s. 0.0 = NOT SEL v hiu ha chc nng Autochange . 0.1336 thi gian hot ng trong khong (thi gian khi tn hiu khi ng l on) gia thay i t ng ng c. Cnh bo! Khi c kch hot, chc nng Autochange i hi kha lin ng (8120 INTERLOCKS = gi tr > 0) kch hot. trong thi gian autochange cng sut u ra b gin on v bin tn dng theo qun tnh, ngn nga thit hi n tip im. Relay logic
ACS550

PFC with Autochange mode

Parameters

180

ACS550 Users Manual

Code Description 8119 AUTOCHNG LEVEL t gii hn trn, nh phn trm ca u ra cng sut, cho autochange logic. Khi u ra t khi iu khin PID/PFC vt qu gii hn ny, autochange l ngn nga. v d, s dng tham s t chi autochange khi h thng bm- qut hot ng gn cng sut ti a . Autochange overview Mc nh ca hot ng autochange l cn bng thi gian gia s dng nhiu ng c trong h thng. ti mt hot ng autochange: mi ng c khc nhau c mt ln kt ni vi u ra ca ACS550 tc n quy nh ca ng c . khi ng ny ca quay mt ng c khc. Chc nng Autochange yu cu: thit b chuyn mch bn ngoi cho thay i kt ni u ra ca bin tn . tham s 8120 INTERLOCKS = gi tr > 0. Autochange c thc hin khi : thi gian chy k t khi autochange t vi thi gian c thit lp bi 8118 AUTOCHNG INTERV. u vo PFC l di mc thit lp bi tham s, 8119 AUTOCHNG LEVEL. Ch : ACS550 lun lun dng theo qun tnh khi autochange c thc hin. trong autochange, chc nng Autochange hin tt c sau y PID output A (xem hnh): 4PFC khi to mt thay i khi thi gian ang chy, k t khi 100% autochange, t c 8118 AUTOCHNG INTERV, v u vo PFC 2PFC l di mc gii hn 8119 AUTOCHNG LEVEL. P 8119 dng tc n nh ng c. 3PFC tt contactor ca tc n nh ng c. 3PFC khi ng tng dn b m, thay i khi ng 4PFC cho cc ng c. 2PFC xc nh ng c tip theo trong ng dn nh tc n t 1PFC nh ng c . tt contactor ng c trn , nu ng c ang chy P 8122 bt k ng c khc chy khng b gin on. P 8118 P 8118 bt contactor tc n nh mi ca ng c B autochange chuyn mch kt ni ng c n A = Area above 8119 AUTOCHNG LEVEL ngun in u ra ACS550. autochange not allowed. khi ng ng c tr cho ti gian 8122 PFC START DELAY. B = Autochange occurs. khi ng n nh tc ng c . 1PFC, etc. = PID output associated with each motor. xc nh ng c tip theo tc khng i quay . chuyn mch ng c trn on, nhng ch nu tc quy nh ng c mi chy (nh tc ng c khng i) bc ny gi mt s bng ca ng c chy trc v sau khi autochange. tip tc vi cc hot ng PFC bnh thng . Output Starting order counter frequency hot ng ca khi ng m : 2 aux No aux 1 aux motors motors motor tham s u ra relay xc nh (14011403 v fMAX 14101412) t ra trnh t ng c ban u . (s tham s thp nht vi gi tr 31 (PFC) xc nh kt ni relay n 1PFC, ng c u tin, v so on.) ban u, 1PFC = quy nh tc ng c, 2PFC = 1st ng c ph, v,v ... trnh t t ng thay i u tin n: 2PFC = tc quy nh ng c, 3PFC = 1st ng c ph , , 1PFC = ng c Area ph cui cng . Autochange trnh t t ng thay i tip theo ln na, v nh vy. is allowed PID output nu t ng thay i khng th khi ng mt ng c cn thit bi v Khng khch hot ng c c vo khp , bin tn hin th mt bo ng 100% P 8119 (2015, PFC I LOCK). khi ngun cung cp cho ACS550 b tt, b m bo ton v tr quay hin ti ca Autochange vo b nh vnh vin. khi c in tr li , Autochange khi ng ti v tr c lu tr trong b nh. nu cu hnh relay PFC c thay i (hoc nu gi tr cho php ca PFC c thay i), v tr c t li. (xem bullet u tin trn .)

Parameters

ACS550 Users Manual

181

Code m t 8120 INTERLOCKS Xc nh hot ng ca chc nng kha lin ng. khi chc nng kha lin ng c kch hot: mt kha lin ng ang hot ng khi lnh kch hot ca n l khng c . mt kha lin ng khng hot ng khi lnh kch hot ca n l c . ACS550 s khi ng nu nu xy ra mt lnh khi ng khi tc quy nh ng c kha lin ng l hot ng bng iu khin hin th mt bo ng (2015, PFC I LOCK). Mi dy dn kha lin ng trong mch nh sau: dy dn tip in ca chuyn i bt /tt ng c n mch kha lin ng PFC logic ca bin tn c th cng nhn rng ng c c tc v khi ng ng c tip theo l c sn. dy dn tip in ca relay nhit ng c (hoc thit b bo v trong mch ng c) n u vo kha kin ng PFC logic bin tn c th nhn ra rng ng c c li v dng ng c. 0 = NOT SEL v hiu ha chc nng kha lin ng. tt c cc u vo s l c sn cho cc mc ch khc nhau . yu cu 8118 AUTOCHNG INTERV = 0 (chc nng Autochange phi v hiu ha nu chc nng kha lin ng b v hiu ha.) 1 = DI1 cho php chc nng kha lin ng v giao cho mt u vo s (khi ng vi DI1) cho tn hiu kha lin ng cho mi relay PFC. n nh c xc nh trong bng di y v ty thuc vo : s lng ca relay PFC [s ca tham s 14011403 v 14101412 vi gi tr = 31 (PFC)] trng thi chc nng Autochange (v hiu ha nu 8118 AUTOCHNG INTERV = 0, v nu khng c kch hot ). S. PFC relays 0 1 Autochange v hiu ha (P 8118) DI1: Speed Reg Motor DI2DI6: Free DI1: Speed Reg Motor DI2: Relay PFC u tin DI3DI6: Free DI1: Speed Reg Motor DI2: Relay PFC u tin DI3: Relay PFC th hai DI4DI6: Free DI1: Speed Reg Motor DI2: Relay PFC u tin DI3: Relay PFC th hai DI4: Relay PFC th ba DI5DI6: Free DI1: Speed Reg Motor DI2: Relay PFC u tin DI3: Relay PFC th hai DI4: Relay PFC th ba DI5: Relay PFC th t DI6: Free DI1: Speed Reg Motor DI2: Relay PFC u tin DI3: Relay PFC th hai DI4: Relay PFC th ba DI5: Relay PFC th t DI6: Relay PFC th nm Khng cho php Autochange kch hot (P 8118) Khng cho php DI1: Relay PFC u tin DI2DI6: Free DI1: Relay PFC u tin DI2: Second PFC Relay DI3DI6: Free DI1: Relay PFC u tin DI2: Relay PFC th hai DI3: Relay PFC th ba DI4DI6: Free DI1: Relay PFC u tin DI2: Relay PFC th hai DI3: Relay PFC th ba DI4: Relay PFC th t DI5DI6: Free DI1: Relay PFC u tin DI2 Relay PFC th hai DI3: Relay PFC th ba DI4: Relay PFC th t DI5: Relay PFC th nm DI6: Free DI1: Relay PFC u tin DI2: Relay PFC th hai DI3: Relay PFC th ba DI4: Relay PFC th t DI5: Relay PFC th nm DI6: Relay PFC th su

Parameters

182

ACS550 Users Manual

Code Description 2 = DI2 cho php chc nng kha lin ng v giao cho mt u vo s (khi ng vi DI2) mt tn hiu kha lin ng cho mt relay PFC. n nh c xc nh trong bng di y v ty thuc vo : s lng ca relay PFC [s ca tham s 14011403 v 14101412 vi gi tr = 31 (PFC)] trng thi chc nng Autochange (v hiu ha nu 8118 AUTOCHNG INTERV = 0, v nu khng c kch hot). No. PFC relays 0 Autochange v hiu ha (P 8118) DI1: Free DI2: Speed Reg Motor DI3DI6: Free DI1: Free DI2: Speed Reg Motor DI3: Relay PFC u tin DI4DI6: Free DI1: Free DI2: Speed Reg Motor DI3: Relay PFC u tin DI4: Relay PFC th hai DI5DI6: Free DI1: Free DI2: Speed Reg Motor DI3: Relay PFC u tin DI4: Relay PFC th hai DI5: Relay PFC th ba DI6: Free DI1: Free DI2: Speed Reg Motor DI3: Relay PFC u tin DI4: Relay PFC th hai DI5: Relay PFC th ba DI6: Relay PFC th t Khng cho php Autochange kch hot (P 8118) Khng cho php

DI1: Free DI2: Relay PFC u tin DI3DI6: Free DI1: Free DI2: Relay PFC u tin DI3: Relay PFC th hai DI4DI6: Free DI1: Free DI2: Relay PFC u tin DI3: Relay PFC th hai DI4: Relay PFC th ba DI5DI6: Free DI1: Free DI2: Relay PFC u tin DI3: Relay PFC th hai DI4: Relay PFC th ba DI5: Relay PFC th t DI6: Free DI1: Free DI2: Relay PFC u tin DI3: Relay PFC th hai DI4: Relay PFC th ba DI5: Relay PFC th t DI6: Relay PFC th nm Khng cho php

Khng cho php

Parameters

ACS550 Users Manual

183

Code Description 3 = DI3 cho php chc nng kha lin ng v giao cho mt u vo s (khi ng vi DI3) mt tn hiu kha lin ng Cho mt relay PFC. n nh c xc nh trong bng di y v ty thuc vo: s lng ca relay PFC [s ca tham s 14011403 v 14101412 vi gi tr = 31 (PFC)] trng thi chc nng Autochange (v hiu ha nu 8118 AUTOCHNG INTERV = 0, v nu khng c kch hot). No. PFC relays 0 Autochange v hiu ha (P 8118) DI1DI2: Free DI3: Speed Reg Motor DI4DI6: Free DI1DI2: Free DI3: Speed Reg Motor DI4: Relay PFC u tin DI5DI6: Free DI1DI2: Free DI3: Speed Reg Motor DI4: Relay PFC u tin DI5: Relay PFC th hai DI6: Free DI1DI2: Free DI3: Speed Reg Motor DI4: Relay PFC u tin DI5: Relay PFC th hai DI6: Third PFC Relay Khng cho php Autochange kch hot (P 8118) Khng cho php

DI1DI2: Free DI3: Relay PFC u tin DI4DI6: Free DI1DI2: Free DI3: Relay PFC u tin DI4: Relay PFC th hai DI5DI6: Free DI1DI2: Free DI3: Relay PFC u tin DI4: Relay PFC th hai DI5: Relay PFC th ba DI6: Free DI1DI2: Free DI3: Relay PFC u tin DI4: Relay PFC th hai DI5: Relay PFC th ba DI6: Relay PFC th t Khng cho php

56

Khng cho php

4 = DI4 cho php chc nng kha lin ng v giao cho mt u vo s (khi ng vi DI4) mt tn hiu kha lin ng cho mt relay PFC. n nh c xc nh trong bng di y v ty thuc vo: s lng ca relay PFC [s ca tham s 14011403 and 14101412 with value = 31 (PFC)] trng thi chc nng Autochange (v hiu ha nu 8118 AUTOCHNG INTERV = 0, v nu khng c kch hot). No. PFC relays 0 Autochange v hiu ha (P 8118) DI1DI3: Free DI4: Speed Reg Motor DI5DI6: Free DI1DI3: Free DI4: Speed Reg Motor DI5: Relay PFC u tin DI6: Free DI1DI3: Free DI4: Speed Reg Motor DI5: Relay PFC u tin DI6: Relay PFC th hai Khng cho php Autochange kch hot (P 8118) Khng cho php

DI1DI3: Free DI4: Relay PFC u tin DI5DI6: Free DI1DI3: Free DI4: Relay PFC u tin DI5: Relay PFC th hai DI6: Free DI1DI3: Free DI4: Relay PFC u tin DI5: Relay PFC th hai DI6: Relay PFC th ba Khng cho php

46

Khng cho php

Parameters

184

ACS550 Users Manual

Code Description 5 = DI5 cho php chc nng kha lin ng v giao cho mt u vo s (khi ng vi DI5) mt tn hiu kha lin ng Cho mt relay PFC. n nh c xc nh trong bng di y v ty thuc vo: s lng ca relay PFC [s ca tham s 14011403 and 14101412 with value = 31 (PFC)] trng thi chc nng Autochange (v hiu ha nu 8118 AUTOCHNG INTERV = 0, v nu khng c kch hot ). No. PFC relays 0 Autochange v hiu ha (P 8118) DI1DI4: Free DI5: Speed Reg Motor DI6: Free DI1DI4: Free DI5: Speed Reg Motor DI6: Relay PFC u tin Khng cho php Autochange kch hot (P 8118) Khng cho php

36

Khng cho php

DI1DI4: Free DI5: Relay PFC u tin DI6: Free DI1DI4: Free DI5: Relay PFC u tin DI6: Relay PFC th hai Khng cho php

6 = DI6 cho php chc nng kha lin ng v giao cho u vo s DI6 mt tn hiu kha lin ng cho quy nh tc ng c. yu cu 8118 AUTOCHNG INTERV = 0. No. PFC relays 0 1 26 Autochange v hiu ha DI1DI5: Free DI6: Speed Reg Motor Khng cho php Khng cho php Autochange kch hot Khng cho php DI1DI5: Free DI6: Relay PFC u tin Khng cho php

Parameters

ACS550 Users Manual

185

Code Description 8121 REG BYPASS CTRL Chn iu chnh -kim sot mch vng. khi c kch hot , iu chnh -kim sot mch vng cung cp mt c ch kim sot n gin m khng iu chnh PID. s dng iu chnh -kim sot mch vng ch trong ng dng fOUT c bit . 0 = NO v hiu ha iu chnh -kim sot mch vng. Bin tn fMAX s dng tham chiu bnh thng PFC: 1106 REF2 SELECT. 1 = YES cho php iu chnh -kim sot mch vng. qu trnh iu chnh PID c b qua. Gi tr thc t ca PID c s dng nh tham chiu P 8110 PFC (u vo). Bnh thng EXT REF2 c s dng P 8109 nh tham chiu PFC bin tn s dng tn hiu phn hi xc nh bi 4014 FBK SEL (hoc 4114) cho tn s tham chiu PFC. P 8113 hnh bn cho thy mi quan h gia tn hiu kim sot 4014 FBK SEL (hoc 4114) v iu chnh tc P 8112 ng c l tn s trong mt h thng ba ng c fMIN . V d : trong biu di y, u ra trm bm c iu khin bi xc nh dng in u vo vo (A). A B C P 4014 (%)

A = ng c ph khng chy B = chy mt ng c ph Mains 3~ 3 3 ACS550 P1 P2 P3 3 A Sewage tank P2 M 3~ P3 Outlet pipe3 3 P1 M 3~ Outlet pipe2 3 Contactors 3 C = chy hai ng c ph

M 3~ Outlet pipe1

Inlet pipe

8122

PFC START DELAY Thit lp khi ng tr cho tc quy nh ca ng c trong h thng. s dng s tr, bin tn lm cng vic nh sau : bt contactor ca tc quy nh ng c kt ni ng c n u ra ngun in ACS550. thi gian khi ng tr ca ng c 8122 PFC START DELAY. khi ng iu chnh tc ng c . khi ng ng c ph. Xem tham s 8115 cho tr. Cnh bo ! ng c c trang b vi khi ng sao / tam gic i hi mt PFC Start Delay. sau khi u ra relay ACS550 chuyn i ng c on, khi ng sao / tam gic phi chuyn sang kt ni sao v v sau cho kt ni tam gic trc khi bin tn p dng ngun in. v vy, PFC khi ng tr phi di hn thi gian ci t ca khi ng sao / tam gic.

8123

PFC ENABLE Chn kim sot PFC. Khi c kch hot, kim sot PFC: chuyn i trong, hoc ngoi, tc ng c ph khng i nh h s ti tng hoc gim. tham s 8109 START FREQ 1 n 8114 LOW FREQ 3 xc nh cc im chuyn i trong quan h cc u ra tn s bin tn. iu chnh ng ra tc ng c xung , nh ng c ph c thm vo, v iu chnh ng ra tc ng c ln, nh ng c ph c ly ra khi mch. cung cp chc nng kha lin ng, nu c kch hot. yu cu 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ). 0 = NOT SEL v hiu ha kim sot PFC. 1 = ACTIVE cho php kim sot PFC.

Parameters

186

ACS550 Users Manual

Code 8124

Description ACC IN AUX STOP Thit lp PFC thi gian tng tc t khng n tn s ln nht theo dc. PFC dc tng tc : p dng cho tc quy nh ng c, khi mt ng c ph c tt. thay th dc tng tc xc nh trong nhm 22: ACCEL/DECELl. ch p dng cho n khi u ra ng c tng theo quy nh bi mt i lng bng n u ra ca tt ng c ph. Sau tng tc theo dc xc nh p dng trong nhm 22: ACCEL/DECEL. 0 = NOT SEL. 0.11800 kch hot chc nng ny bng cch s dng gi tr nhp vo nh thi gian tng tc. fOUT A B

P 8125 Aux. motor 1 0

P 8124

8125

DEC IN AUX START Thit lp PFC thi gian gim tc t tn s ln nht-n khng theo dc . PFC gim tc theo dc : p dng cho tc quy nh ng c, khi mt ng c ph c bt. thay th dc gim tc xc nh trong nhm 22: ACCEL/DECEL. ch p dng cho n khi u ra ng c gim theo quy nh bi mt i lng bng n u ra ca bt ng c ph. Sau gim tc theo dc xc nh p dng trong nhm nhm 22: ACCEL/DECEL. 0 = NOT SEL. 0.11800 kch hot chc nng ny bng cch s dng gi tr nhp vo nh thi gian gim tc.

A = iu chnh tc ng c tng tc bng cch s dng Group 22:ACCEL/DECEL tham s (2202 hoc 2205). B = iu chnh tc ng c gim tc bng cch s dng Group 22: ACCEL/DECEL tham s (2203 hoc 2206). Ti ng c ph khi ng, iu chnh tc ng c gim tc bng cch s dng 8125 DEC IN AUX START. Ti ng c ph dng, iu chnh tc ng c tng tc bng cch s dng 8124 ACC IN AUX STOP.

8126

TIMED AUTOCHNG Thit lp t ng thay i bng cch s dng chc nng hn gi. Xem tham s 8119 AUTOCHNG LEVEL. 0 = NOT SEL. 1 = TIMED FUNC 1 cho php t ng thay i khi chc nng hn gi 1 hot ng. 24 = TIMED FUNC 24 cho php t ng thay i khi chc nng hn gi 24 hot ng.

8127

MOTORS Thit lp s thc t ca b iu khin PFC iu khin cc ng c (nhiu nht 7 ng c, 1 tc iu chnh, 3 kt ni trc tip v 3 ng c thay th). gi tr ny cng bao gm iu chnh tc ng c. gi tr ny phi ph hp vi s lng relay cho PFC nu chc nng t ng thay i c s dng . nu chc nng t ng thay i c s dng, tc ng c thay i l khng cn thit cho u ra relay phn tn n PFC nhng n cn bao gm cc gi tr ny.

8128

AUX START ORDER Thit lp trt t khi ng ca ng c ph . 1 = EVEN RUNTIME thi gian phn chia c kch hot. trnh t khi ng ph thuc vo thi gian chy . 2 = RELAY ORDER trnh t khi ng l c nh c th t cc relay.

Parameters

ACS550 Users Manual

187

nhm 98: OPTIONS Cu hnh nhm ny cho cc ty chn, c bit, cho php giao tp ni tip vi bin tn.
Code 9802 Description COMM PROT SEL Chn giao thc truyn thng. 0 = NOT SEL khng giao thc truyn thng c chn. 1 = STD MODBUS bin tn giao tip vi Modbus thng qua ng truyn RS485 (X1-truyn thng, u cui ). xem thm nhm 53: EFB PROTOCOL. 4 = EXT FBA bin tn giao tip thng qua b chuyn i fieldbus module trong ty chn khe cm 2 ca bin tn. xem thm nhm 51: EXT COMM MODULE.

Parameters

188

ACS550 Users Manual

Parameters

ACS550 Users Manual

189

Embedded fieldbus

Tng quan
ACS550 c th c thit lp chp nhn mt h thng kim sot t bn ngoi bng cch s dng giao thc truyn thng ni tip theo tiu chun. khi s dng giao thc ni tip , ACS550 c th hoc : nhn c tt c cc thng tin kim sot t fieldbus, hoc . c kim sot t mt s kt hp ca kim sot fieldbus v cc im kim sot c sn khc , chng hn nh cc u vo s hoc tng t v bng iu khin .
B iu khinFieldbus Fieldbus

Cc thit b khc

S dng cch kt ni khc : t vo fieldbus tiu chun (EFB) ti u ni X1:2832 b chuyn i fieldbus (FBA) module c gn vo khe cm 2 (ty chn Rxxx).

Hai cu hnh h thng thng tin c bn l c sn: embedded fieldbus (EFB) s dng giao din RS485 ti u ni X1:2832 trn bo mch iu khin , h thng kim sot c th giao tip vi bin tn s dng giao thc Modbus. (cho giao thc v m t thng tin, xem phn Modbus protocol technical data v ABB control profiles technical data sau ny trong chng .) fieldbus adapter (FBA) xem chng Fieldbus adapter trn trang 221. Giao din iu khin Ni chung, giao din iu khin c bn gia Modbus bin tn bao gm : u ra words kim sot Word tham chiu 1 tham chiu 2 u vo words tnh trng Word gi tr thc t 1 gi tr thc t 2

Embedded fieldbus

190

ACS550 Users Manual

gi tr thc t 3 gi tr thc t 4 gi tr thc t 5 gi tr thc t 6 gi tr thc t 7 gi tr thc t 8 Ni dung ca nhng words c xc nh bi cu hnh. bit thm chi tit v cu hnh s dng, Xem phn ABB control profiles technical data trn trang 209. Ch : nhng word ng ra v ng vo c s dng nh ly t im iu khin fieldbus hin th . Cho v d mt u ra m t d liu lu thng t b iu khin fieldbus n bin tn v xut hin nh mt u vo im iu khin ca hin th.

Planning
Quy hoch mng li to nn a ch theo cc cu hi sau : lm sao loi v s lng cc thit b phi c kt ni n mng li ? lm sao kim sot thng tin phi c gi xung n bin tn ? lm sao thng tin phn hi phi c gi t bin tn n h thng kim sot ?

Mechanical and electrical installation EFB


Cnh bo! Kt ni ch c thc hin trong khi bin tn ngt kt ni t ngun in . u ni bin tn 2832 dnh cho truyn thng RS485. Use Belden 9842 hoc tng ng. Belden 9842 l mt xon kp, cp c bo v vi mt sng tr khng l 120 ohm. s dng mt trong nhng cp xon che chn cho lin kt RS485 . s dng cp ny kt ni tt c u ni A (-) vi nhau v tt c u ni B (+) vi nhau. s dng mt dy dn trong cp khc cho ni t hp l (u ni 31), li mt dy khng s dng . khng ni t trc tip mng RS485 ti bt k im no. Ni t tt c cc thit b trn mng bng cch s dng cc thit b u cui ni t tng ng. nh mi khi, cc dy tp t khng nn to vng knh, v tt c cc thit b c ni t mt mat chung. kt ni lin kt RS485 trong mt bus chui xch, m khng c kin kt nh.

Embedded fieldbus

ACS550 Users Manual

191

gim ting n trn mng, u ni h thng RS485 s dng in tr 120 ti cui ca h thng. s dng cng tc DIP kt ni hoc tc in tr u cui. xem s v bng sau .
u ni station Station Station u ni station

X1 28 29 30 31 32

Identification Screen B (Positive +) A (Negative -) AGND Screen

Hardware description RS485 Multidrop application SCR + GND SCR + GND 28 29 30 31 32 SCR B A AGND SCR RS485 interface J2 J2
ON ON

OFF position ON position Bus termination

kt ni ca cp l chn mt u ca cp vo bin tn. trn mt u, kt ni cp l chn n u ni 28, v u bn kia kt ni n u ni 32. khng kt ni cc cp l chn vo v ra cng mt u ni, v lm nh th s lm che chn lin tc . i vi thng tin cu hnh xem cc phn sau : thit lp truyn thng EFB trn trang 191 kch hot chc nng kim sot bin tn EFB trn trang 193 giao thc EFB thch hp d liu k thut c th. Cho v d, Modbus protocol technical data trn trang 201.

Communication set-up EFB


Chn giao tip ni tip kch hot giao tip ni tip, xem tham s 9802 COMM PROT SEL = 1 (STD MODBUS). Ch : nu bn khng th thy la chn mun c trn bng iu khin, bin tn ca bn khng c phn mm giao thc trong b nh ng dng .

Embedded fieldbus

192

ACS550 Users Manual

Cu hnh giao tip ni tip Thit lp 9802 t ng ci t cc gi tr mc nh thch hp trong cc tham s xc nh qu tnh truyn thng. Cc thng s v m t c xc nh di y . Trong , lu rng v tr Id c th c iu chnh .
Code 5301 EFB PROTOCOL ID Bao gm vic xc nh v sa i chng trnh ca giao thc. Description Protocol reference Modbus Khng c chnh sa . nhp bt k gi tr khc khng cho tham s 9802 COMM PROT SEL,thit lp tham s ny t ng. nh dng l: XXYY, trong XX = giao thc ID, v YY = sa i chng trnh. t mi bin tn trn mng vi mt gi tr duy nht cho tham s ny . Khi giao thc ny c la chn, gi tr mc nh cho tham s ny l : 1 Ch : cho mt a ch mi c nh hng, cng sut bin tn phi l chu k hoc 5302 u tin phi c t n 0 trc khi chn mt a ch mi. 5302 = 0 v tr knh RS485 trong reset, v hiu ha giao tip. 5303 EFB BAUD RATE Xc nh tc truyn thng cho lin kt RS485 trong kbits trn giy (kbits/s). 1.2 kb/s 2.4 kb/s 4.8 kb/s 9.6 kb/s 5304 19.2 kb/s 38.4 kb/s 57.6 kb/s 76.8 kb/s Khi giao thc nay c la chn , gi tr mc nh cho tham s ny l: 1 Khi giao thc nay c la chn , gi tr mc nh cho tham s ny l 9.6 kb/s

5302

EFB STATION ID Xc nh a ch ca nt lin kt RS485 .

EFB PARITY Xc nh di d liu, chn l v bits dng c S dng vi giao tip RS485 . cc thit lp tng t phi c thit lp trong tt c cc trm trn mng.

0 = 8 NONE 1 8 bits d liu , khng chn l, mt bit dng. 1 = 8 NONE 2 8 bits d liu, khng chn l, hai bits dng. 2 = 8 EVEN 1 8 bits d liu, chn, mt bit dng. 3 = 8 ODD 1 8 bits d liu, l, mt bit dng. 5305 EFB CTRL PROFILE Chn thng tin truyn thng c chn bi cc giao thc EFB. 0 = ABB DRV LIM hot ng ca kim sot/trng thi Words ph hp vi ABB Drives Profile, nh c s dng trong ACS400. 1 = DCU PROFILE hot ng ca kim sot/trng thi Words ph hp vi 32-bit DCU Profile. 2 = ABB DRV FULL hot ng ca kim sot/trng thi Words ph hp vi ABB Drives Profile, nh c s dng trong ACS600/800. Khi giao thc ny c la chn , gi tr mc nh cho tham s ny l: 0

Ch : sau khi bt k thay i cc thit lp giao tip, giao thc ny phi c kch hot bi chu k ngun in bin tn , hoc bng cch xa v sau khi phc li v tr Id (5302).

Embedded fieldbus

ACS550 Users Manual

193

Activate drive control functions EFB


iu khin bin tn fieldbus kim sot chc nng khc nhau ca bin tn i hi cu hnh n : bo cho bin tn chp nhn iu khin fieldbus ca cc chc nng . xc nh nh mt u vo fieldbus, bt k d liu bin tn cho kim sot xc nh nh mt u ra fieldbus, bt k d liu kim sot theo yu cu bi bin tn . Nhng thnh phn sau y m t, mc chung , cu hnh cn thit cho mi chc nng kim sot . bit chi tit giao thc c th , xem ti liu cung cp vi module FBA. Start/Stop Direction control S dng fieldbus cho khi ng/dng/kim sot hng ca bin tn yu cu : thit lp gi tr tham s bin tn nh bn di b iu khin fieldbus cung cp lnh(s) v tr thch hp. (v tr ny c xc nh bi Protocol Reference, l giao tc ph thuc .)
Modbus1 protocol reference Drive parameter 1001 1002 1003
1

Value

Description ABB DRV DCU PROFILE 40031 bits 0, 1 40031 bits 0, 1 40031 bit 3 Khi ng/dng bi fieldbus 40001 bits 03 Vi chn Ext1. Khi ng/dng bi fieldbus 40001 bits 03 Vi chn Ext2 . hng bi fieldbus. 4002/40032

EXT1 COMMANDS 10 (COMM) EXT2 COMMANDS 10 (COMM) DIRECTION 3 (REQUEST)

For Modbus, cc tham chiu giao thc c th ph thuc vo thng tin c s dng, t hai ct c hin th trn bng. mt ct tham chiu n thng tin ABB Drives , chn khi tham s 5305 = 0 (ABB DRV LIM) hoc 5305 = 2 (ABB DRV FULL). Ct tham chiu khc n thng tin DCU chn khi Tham s 5305 = 1 (DCU PROFILE). Xem phn ABB control profiles technical data trn trang 209. Tham chiu ny cung cp kim sot hng mt tham chiu m cung cp hng quay ngc li.

Embedded fieldbus

194

ACS550 Users Manual

Input reference select S dng fieldbus n cung cp tham chiu u vo yu cu bin tn: cc gi tr tham chiu bin tn thit lp nh mc nh di y b iu khin fieldbus cung cp tham chiu word(s) v tr thch hp. (v tr c xc nh bi giao thc tham chiu, vi giao thc ph thuc.)
Drive parameter Value Description Modbus protocol reference
ABB DRV DCU PROFILE

1102 1103 1106

EXT1/EXT2 SEL 8 (COMM) REF1 SELECT REF2 SELECT 8 (COMM) 8 (COMM)

Thit lp tham chiu chn bi fieldbus. Tham chiu u vo 1 bi fieldbus. Tham chiu u vo 2 bi fieldbus.

40001 bit 11

40031 bit 5

40002 40003

Reference Scaling Trng hp cn thit, THAM CHIU c th t l. xem sau y, nh tng ng : Modbus Register 40002 trong phn Modbus protocol technical data trn trang 201 Reference scaling trong phn ABB control profiles technical data trn trang 209. Miscellaneous drive control S dng fieldbus cho bin tn kim sot hn hp cc yu cu : cc gi tr tham s bin tn nh mc nh di y . b iu khin fieldbus cung cp lnh (s) v tr thch hp. (v tr c xc nh bi giao thc tham chiu, vi giao thc ph thuc.)
Modbus protocol reference
ABB DRV DCU PROFILE

Drive parameter

Value

Description

1601 1604 1606 1607 1608 1609 2013 2014 2201

RUN ENABLE

7 (COMM) 8 (COMM) 8 (COMM) 1 (SAVE) 1 2 7 (COMM) 7 (COMM) 7 (COMM) 7 (COMM) 7 (COMM)

cho php chy bi fieldbus. reset li bi fieldbus. ngun cho kha cc b la chn l fieldbus. Lu thay i thng s n b nh (sau tr v gi tr 0). ngun cho php khi ng 1 l fieldbus Command word. ngun cho php khi ng 2 l fieldbus Command word. ngun cho momen xon nh nht chn l fieldbus. ngun cho momen xon ln nht chn l fieldbus. ngun cho cp dc chn l fieldbus.

40001 bit 3 40031 bit 6 (inverted) 40001 bit 7 40031 bit 4 Does not apply 40031 bit 14 41607 Does not apply. 40032 bit 2 40032 bit 3 40031 bit 15

FAULT RESET SEL LOCAL LOCK

PARAM SAVE

START ENABLE

START ENABLE

MIN TORQUE SEL

MAX TORQUE SEL

ACC/DEC

1/2 SEL

40031 bit 10

Embedded fieldbus

ACS550 Users Manual

195

Relay output control S dng fieldbus cho kim sot u ra relay theo yu cu : thit lp gi tr tham s bin tn nh xc nh di y . b iu khin fieldbus cung cp, m nh phn, lnh relay (s) v tr thch hp . (v tr ny c xc nh bi Protocol Reference, l giao thc ph thuc.)
Modbus protocol reference
ABB DRV DCU PROFILE

Drive parameter 1401 1402 1403 14101 14111 14121


1

Value 35 (COMM) 35 (COMM) 35 (COMM) 35 (COMM) 35 (COMM) 35 (COMM)

Description u ra Relay 1 iu khin bi fieldbus. u ra Relay 2 iu khin bi fieldbus. u ra Relay 3 iu khin bi fieldbus. u ra Relay 4 iu khin bi fieldbus. u ra Relay 5 iu khin bi fieldbus. u ra Relay 6 iu khin bi fieldbus.

RELAY OUTPUT 1 RELAY OUTPUT 2 RELAY OUTPUT 3 RELAY OUTPUT 4 RELAY OUTPUT 5 RELAY OUTPUT 6

40134 bit 0 hoc 00033 40134 bit 1 hoc 00034 40134 bit 2 hoc 00035 40134 bit 3 hoc 00036 40134 bit 4 hoc 00037 40134 bit 5 hoc 00038

Nhiu hn 3 relays i hi b sung mt module relay m rng.

Ch : trng thi Relay xy ra thng tin phn hi m khng cn cu hnh nh nh ngha di y.


Modbus protocol reference
ABB DRV DCU PROFILE

Drive parameter

Description

0122 0123

RO RO

1-3 STATUS 4-6 STATUS

Relay 13 status. Relay 46 status.

40122 40123

Kim sot u ra tng t S dng fieldbus cho kim sot u ra tng t (e.g. PID im t) yu cu : gi tr tham s bin tn t nh nh ngha di y . b iu khin fieldbus cung cp gi tr tng t(s) v tr thch hp. (v tr ny xc nh bi giao thc tham chiu, l giao thc ph thuc.)
Drive parameter Value Description Modbus protocol reference
ABB DRV DCU PROFILE

1501 0135 1507 0136

AO1 CONTENT SEL COMM VALUE

135 (COMM VALUE 1) 136 (COMM VALUE 2)

ng ra tng t 1 kim sot bi vn bn cho tham s 0135. ng ra tng t 2 kim sot bi vn bn cho tham s 0136.

40135 40136

AO2 CONTENT SEL COMM VALUE

Embedded fieldbus

196

ACS550 Users Manual

PID control setpoint source S dng cc thit lp sau y chn fieldbus nh ngun im t cho vng lp PID :
Modbus protocol reference
ABB DRV DCU PROFILE

Drive parameter

Value

Description

4010 4110 4210

SET POINT SEL

8 (COMM VALUE 1) 9 (COMM+AI1) 10 (COMM*AI1)

(Set 1)
SET POINT SEL

im t la u vo tham chiu 2 (+/-/* AI1)

40003

(Set 2)
SET POINT SEL

(Ext/Trim)

Communication fault Khi s dng kim sot fieldbus, xc nh hnh ng ca bin tn nu giao tip ni tip b mt .
Drive parameter 3018 Value Description Thit lp cho bin tn phn ng thch hp.

COMM FAULT FUNC 0 (NOT SEL) 1 (FAULT) 2 (CONST SP7) 3 (LAST SPEED) COMM FAULT TIME

3019

t thi gian tr trc khi hnh ng trn mt truyn thng.

Embedded fieldbus

ACS550 Users Manual

197

Feedback from the drive EFB


c xc nh trc thng tin phn hi u vo n b iu khin (cc u ra bin tn) c ngha c xc nh trc khi to sn bi giao thc. Phn hi ny khng i hi cu hnh bin tn . Bng danh sch di y l mu ca d liu phn hi . Cho mt danh sch y , xem u vo word/im/danh sch i tng trong d liu k thut cho giao thc khi ng thch hp trn trang 201.
Tham s bin tn 0102 0103 0104 0105 0106 0107 0109 0301 0301 0118 SPEED OUTPUT FREQ CURRENT TORQUE POWER DC BUS VOLTAGE OUTPUT VOLTAGE FB CMD WORD1 bit 0 (STOP) FB CMD WORD1 bit 2 (REV) 1 DI 1-3 STATUS bit 0 (DI3) Modbus protocol reference
ABB DRV DCU PROFILE

40102 40103 40104 40105 40106 40107 40109 40301 bit 0 40301 bit 2 40118

Ch : vi Modbus, bt k tham s c th ng dn c s dng bng cch nh dng: 4 sau y bi s lng tham s .

Actual value scaling T l ca gi tr thc t c th l giao thc ph thuc. Ni chung, cho gi tr thc t , t l thng tin phn hi s nguyn bng cch s dng chnh xc ca tham s. (xem phn Complete parameter list trn trang 85 cho chnh xc ca tham s.) v d :
Feedback integer 1 10 Parameter resolution 0.1 mA 0.1% (Feedback integer) (Parameter resolution) = Scaled value 1 0.1 mA = 0.1 mA 10 0.1% = 1%

Trng hp cc tham s l phn trm, Complete parameter descriptions chn quy nh lm sao tham s tng ng vi 100%. Trong trng hp ny, chuyn i t phn trm n n v k thut, nhn bi gi tr ca tham s xc nh 100% v phn chia bi 100%.

Embedded fieldbus

198

ACS550 Users Manual

V d :
Feedback integer 10 100
1 2

Parameter resolution 0.1% 0.1%

Value of the parameter that defines 100% 1500 rpm1 500 Hz2

(Feedback integer) (Parameter resolution) (Value of 100% ref.) / 100% = Scaled value 10 0.1% 1500 RPM / 100% = 15 rpm 100 0.1% 500 Hz / 100% = 50 Hz

Gi s, cho li ca v d ny, rng gi tr thc t s dng tham s 9908 MOT NOM SPEED nh 100% tham chiu v rng 9908 = 1500 rpm. Gi s, cho li ca v d ny, rng gi tr thc t s dng tham s 9907 MOT NOM FREQ nh 100% tham chiu v rng 9907 = 500 Hz.

Diagnostics EFB
Fault queue for drive diagnostics i vi thng tin m t chung ACS550, xem chng Diagnostics trn trang 243. Ba li gn y nht ACS550 c thng bo n fieldbus nh mc nh bn di .
Drive parameter 0401 0412 0413 LAST FAULT PREVIOUS FAULT 1 PREVIOUS FAULT 2 Modbus protocol reference
ABB DRV DCU PROFILE

40401 40412 40413

Serial communication diagnostics Cc vn mng c th gy ra bi nhiu ngun. mt s ngun l : kt ni lng lo dy khng chnh xc (bao gm i ch dy) tip t xu tng i s trm . thit lp khng chnh xc ca bin tn hoc thit b khc trn mng. Phn tch tnh nng chnh d tm s c trn mng EFB bao gm nhm 53: EFB PROTOCOL tham s 53065309. phn Complete parameter descriptions trn trang 98 m t cc thng s c th .

Embedded fieldbus

ACS550 Users Manual

199

Diagnostic situations Phn nh di y m t phn tch cc bin khc nhau triu chng s c v hnh ng khc phc . Normal operation Trong thi gian mng hot ng bnh thng, 53065309 gi tr tham s hot ng nh sau ti mi bin tn : 5306 EFB OK MESSAGES tng ln (tng ln cho mi tin nhn c xc nhn v a ch n bin tn ny). 5307 EFB CRC ERRORS khng tng ln tt c (tng ln khi nhn c tin nhn CRC khng hp l ). 5308 EFB UART ERRORS khng tng ln tt c (tng ln khi c trng li nh dng c pht hin, chng hn nh tnh chn l hoc khung li). 5309 EFB STATUS gi tr khc nhau ty thuc vo lu lng trn mng. Loss of communication ng thi ACS550, nu truyn thng b mt, c cu hnh trc trong phn Communication fault trn trang 196. cc tham s l 3018 COMM FAULT FUNC v 3019 COMM FAULT TIME. Phn Complete parameter descriptions trn trang 98 m t cc thng s c th . No master station on line Nu khng c trm ch trn ng truyn: Neither the EFB OK MESSAGES cng khng phi li (5307 EFB CRC ERRORS v 5308 EFB UART ERRORS) tng trn bt k cc trm. chnh xc : kim tra xem tng th mng li c kt ni v lp trnh ng trn mng . xc minh rng cp c kt ni v rng n khng b ct hoc ngn mch . Duplicate stations Nu hai hoc nhiu trm c tng i s lng : hai hoc nhiu bin tn khng th cng a ch . mi khi c hoc vit t mt trng thi ring, gi tr cho 5307 EFB CRC ERRORS hoc 5308 EFB UART ERRORS tng ln . chnh xc : xc minh s trm ca tt c cc trm. thay i s trm mu thun . Swapped wires Nu dy truyn thng b i ch (u ni A trn bin tn c kt ni n u ni B mt ci khc ): gi tr ca 5306 EFB OK MESSAGES khng tng ln . gi tr ca 5307 EFB CRC ERRORS v 5308 EFB UART ERRORS tng ln. chnh xc : kim tra xem ng truyn RS-485 khng b tro i.

Embedded fieldbus

200

ACS550 Users Manual

Fault 28 Serial 1 Err Nu bng iu khin ca bin tn hin th m li 28, SERIAL 1 ERR, kim tra cc iu $ $ h thng tng th l xung. chnh xc, gii quyt vn vi h thng tng th . cc kt ni truyn thng l xu. chnh xc, kim tra cc kt ni truyn thng ti bin tn . ht thi gian chn cho bin tn l qu ngn cho vic ci t nht nh. tng th khng phi l kim sot vng bin tn trong quy nh ht thi gian tr., chnh xc ,tng thi gian thit lp bi tham s 3019 COMM FAULT TIME. Faults 3133 EFB1EFB3 Ba m li EFB c lit k cho bin tn trong chng Diagnostics trn trang 243 (m li 3133) l khng c s dng . Intermittent off-line occurrences Cc vn m t trn l nhng vn ph bin nht ACS550 gp phi giao tip ni tip. Cc vn lin tc cng gy ra bi : kt ni nh lng hao mn trn dy gy ra bi cc thit b rung ng ni t khng v che chn trn c hai thit b v trn cp truyn thng .

Embedded fieldbus

ACS550 Users Manual

201

Modbus protocol technical data


Overview Giao thc Modbus c gii thiu bi Modicon, Inc. Cho s dng trong mi trng kim sot c tnh nng iu khin lp trnh Modicon. Do d s dng v ci t . ngn ng thng thng ny PLC nhanh chng c chp nhn nh chun thc t cho kt hp ca nhiu thit b iu khin tng th v ph thuc . Modbus l ni tip, giao thc khng ng b. Cc giao tc l n phng , c trng l mt tn hiu iu khin tng th hoc l thuc. trong khi RS232 c th s dng cho truynthng t im n im gia tn hiu tng th v tn hiu ph thuc, mt lnh ci t chung ,tnh nng a im RS485 trn mng vi mt tn hiu tng th kim sot nhiu thit b ph thuc. ACS550 tnh nng RS485 cho giao din vt l Modbus ca n . RTU Cc c im Modbus xc nh hai phng thc truyn dn khc nhau: ASCII v RTU. ACS550 ch h tr RTU. Feature summary Modbus chc nng m sau y c h tr bi ACS550.
Function Read Coil Status Code (Hex) 0x01 Description c u ra trng thi ring bit. i vi ACS550, bits ring l ca kim sot word c nh x n cun dy 116. cc u ra Relay c nh x lin tc bt u vi cun dy 33 (e.g. RO1=Coil 33). c u ra trng thi ring bit. i vi ACS550, bits ring l ca kim sot word c nh x n u vo 116 hoc 132, ty thuc vo bin dng hot ng . u ni u vo c nh x lin tc bt u vi u vo 33 (e.g. DI1=u vo 33). c nhiu ng sut thanh ghi. i vi ACS550, ton b thit lp tham s c nh x nh ng sut thanh ghi, cng nh ra lnh , tnh trng v gi tr tham chiu . c nhiu thanh ghi u vo. i vi ACS550, 2 knh tng t u vo c nh x nh u vo thanh ghi 1 & 2. Vit tn hiu u ra b ghi . i vi ACS550, bit ring bit ca kim sot word v nh x n cun dy 116. cc u ra Relay c nh x lin tc bt u vi cun dy 33 (e.g. RO1=Coil 33). Vit mt ng sut thanh ghi. i vi ACS550, ton b cc thit lp thng s c nh x nh ng sut thanh ghi, cng nh ra lnh . tnh trng v gi tr tham chiu . Thc hin phn tch Modbus. M ph hi (0x00), Restart (0x01) & Listen Only (0x04) c h tr. Vit nhiu u ra ring bit. i vi ACS550, cc bit ring bit ca kim sot word c nh x n cun dy 116. cc u ra Relay c nh x lin tc bt u vi cun dy 33 (e.g. RO1=Coil 33). Vit nhiu ng sut thanh ghi. i vi ACS550, ton b thit lp tham s c nh x nh ng sut thanh ghi, cng nh ra lnh tnh trng v gi tr tham chiu. chc nng ny kt hp chc nng 0x03 and 0x10 vo mt lnh n .

Read Discrete Input Status

0x02

Read Multiple Holding Registers Read Multiple Input Registers Force Single Coil

0x03

0x04 0x05

Write Single Holding Register Diagnostics

0x06

0x08

Force Multiple Coils 0x0F

Write Multiple Holding Registers Read/Write Multiple Holding Registers

0x10

0x17

Embedded fieldbus

202

ACS550 Users Manual

Mapping summary Bng sau y tm tc cc nh x gia ACS550 (tham s v I/0) v khng gian tham chiu Modbus. Chi tit, xem Modbus addressing di .
ACS550 Control Bits Relay Outputs Modbus reference Coils(0xxxx) Supported function codes 01 Read Coil Status 05 Force Single Coil 15 Force Multiple Coils Status Bits Discrete Inputs Analog Inputs Parameters Control/Status Words References Input Registers(3xxxxx) Holding Registers(4xxxx) 04 Read Input Registers 03 Read 4X Registers 06 Preset Single 4X Register 16 Preset Multiple 4X Registers 23 Read/Write 4X Registers Discrete Inputs(1xxxx) 02 Read Input Status

Communication profiles Khi truyn thng bi Modbus, ACS550 h tr nhiu cu hnh kim sot v tnh trng thng tin. Tham s 5305 EFB CTRL PROFILE chn thng tin c s dng. ABB DRV LIM cc thng tin chnh (v mc nh) l thng tin ABB DRV LIM. Ci t ny ca ABB Drives l chun giao din iu khin vi bin tn ACS400 . ABB Drives thng tin da trn giao din PROFIBUS. N c tho lun chi tit trong cc phn sau y . DCU PROFILE DCU PROFILE h tr m rng kim sot v trng thi giao din n 32 bit . n l giao din ni b gia giao din chnh ca bin tn v t vo mi trng fieldbus . ABB DRV FULL ABB DRV FULL thc thi ca ABB Drives h tr rng l chun kim sot giao din vi bin tn ACS600 v ACS800 . Thc hin h tr ny vi hai word bits kim sot khng c h tr vi thc hin ABB DRV LIM . Modbus addressing Vi Modbus, mi m chc nng ng ng dn n thit lp mt tham chiu Modbus c th . Do , cc s quan trng l khng c bao gm phn a ch ca tin nhn Modbus. Ch : ACS550 h tr khng da trn a ch ca c im k thut Modbus . ng sut thanh ghi 40002 l a ch 0001 trong mt tin nhn Modbus . Tng t, cun dy 33 l a ch nh 0032 trong mt tin nhn Modbus . Tham kho mt ln na tm tc bng trn. Phn sau y m t, c th , bng thit lp mi tham chiu Modbus . 0xxxx Mapping Modbus coils. S bin tn sau y m t thng tin thit lp 0xxxx Modbus c gi l Modbus Coils: tng bit s ca CONTROL WORD (chn bng cch s dng tham s 5305 EFB CTRL PROFILE). u tin cun dy 32 c dnh ring cho mc ch ny.

Embedded fieldbus

ACS550 Users Manual

203

relay u ra trng thi, s c nh tun t vi coil 00033. Bng di y tm tc cc thit lp tham s 0xxxx:
Modbus ref. 00001 00002 00003 00004 00005 00006 00007 00008 00009 00010 00011 00012 00013 00014 00015 00016 00017 00018 00019 00020 00021 00032 00033 00034 00035 00036 00037 00038
1

Internal location (all profiles)


CONTROL WORD Bit 0 CONTROL WORD Bit 1 CONTROL WORD Bit 2 CONTROL WORD Bit 3 CONTROL WORD Bit 4 CONTROL WORD Bit 5 CONTROL WORD Bit 6 CONTROL WORD Bit 7 CONTROL WORD Bit 8 CONTROL WORD Bit 9 CONTROL WORD Bit 10 CONTROL WORD Bit 11 CONTROL WORD Bit 12 CONTROL WORD Bit 13 CONTROL WORD Bit 14 CONTROL WORD Bit 15 CONTROL WORD Bit 16 CONTROL WORD Bit 17 CONTROL WORD Bit 18 CONTROL WORD Bit 19

ABB DRV LIM

DCU PROFILE

ABB DRV FULL

(5305 = 0) OFF11 OFF21 OFF31 START N/A RAMP_HOLD1 RAMP_IN_ZERO1 RESET N/A N/A N/A EXT2 N/A N/A N/A N/A Does not apply

(5305 = 1) STOP START REVERSE LOCAL RESET EXT2 RUN_DISABLE STPMODE_R STPMODE_EM STPMODE_C RAMP_2 RAMP_OUT_0 RAMP_HOLD RAMP_IN_0 REQ_LOCALLOCK N/A TORQLIM2 FBLOCAL_CTL FBLOCAL_REF START_DISABLE1 START_DISABLE2 N/A

(5305 = 2) OFF11 OFF21 OFF31 START RAMP_OUT_ZERO1 RAMP_HOLD1 RAMP_IN_ZERO1 RESET N/A N/A REMOTE_CMD1 EXT2 N/A N/A

Does not apply

Reserved
RELAY OUTPUT 1 RELAY OUTPUT 2 RELAY OUTPUT 3 RELAY OUTPUT 4 RELAY OUTPUT 5 RELAY OUTPUT 6

Reserved Relay Output 1 Relay Output 2 Relay Output 3 Relay Output 4 Relay Output 5 Relay Output 6

Reserved Relay Output 1 Relay Output 2 Relay Output 3 Relay Output 4 Relay Output 5 Relay Output 6

Reserved Relay Output 1 Relay Output 2 Relay Output 3 Relay Output 4 Relay Output 5 Relay Output 6

= Active low

Cho thanh ghi 0xxxx: tnh trng lun lun c th c c . lc cho php ngi dng cu hnh ca bin tn cho kim sot fieldbus. b sung u ra relay l c thm vo tun t .

Embedded fieldbus

204

ACS550 Users Manual

ACS550 h tr m chc nng sau Modbus cho cun dy :


Function code 01 05 15 (0x0F Hex) Description c trng thi cun dy Lc mt cun dy Lc nhiu cun dy

1xxxx Mapping Modbus discrete inputs. Cc phng n bin tn sau y thng tin n thit lp 1xxxx Modbus c gi l u vo Modbus Discrete : tng phng n bit ca STATUS WORD (chn bng cch s dng tham s 5305 EFB CTRL PROFILE). u tin u vo 32 c dnh ring cho mc inh ny. u vo phn cng ring bit, s c nh tun t bt u vi u vo 33. Bng di y tm tc cc thit lp tham chiu 1xxxx :
Modbus ref. 10001 10002 10003 10004 10005 10006 10007 10008 10009 10010 10011 10012 10013 10014 10015 10016 10017 10018 10019 10020 10021 10022 10023 10024 10025 10026 10027 Internal location (all profiles)
STATUS WORD Bit 0 STATUS WORD Bit 1 STATUS WORD Bit 2 STATUS WORD Bit 3 STATUS WORD Bit 4 STATUS WORD Bit 5 STATUS WORD Bit 6 STATUS WORD Bit 7 STATUS WORD Bit 8 STATUS WORD Bit 9 STATUS WORD Bit 10 STATUS WORD Bit 11 STATUS WORD Bit 12 STATUS WORD Bit 13 STATUS WORD Bit 14 STATUS WORD Bit 15 STATUS WORD Bit 16 STATUS WORD Bit 17 STATUS WORD Bit 18 STATUS WORD Bit 19 STATUS WORD Bit 20 STATUS WORD Bit 21 STATUS WORD Bit 22 STATUS WORD Bit 23 STATUS WORD Bit 24 STATUS WORD Bit 25 STATUS WORD Bit 26
ABB DRV DCU PROFILE

(5305 = 0 OR RDY_ON RDY_RUN RDY_REF TRIPPED OFF_2_STA1 OFF_3_STA1 SWC_ON_INHIB ALARM AT_SETPOINT REMOTE ABOVE_LIMIT EXT2 RUN_ENABLE N/A N/A N/A Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved Reserved

2) READY

(5305 = 1)

ENABLED STARTED RUNNING ZERO_SPEED ACCELERATE DECELERATE AT_SETPOINT LIMIT SUPERVISION REV_REF REV_ACT PANEL_LOCAL FIELDBUS_LOCAL EXT2_ACT FAULT ALARM REQ_MAINT DIRLOCK LOCALLOCK CTL_MODE Reserved Reserved Reserved Reserved Reserved REQ_CTL

Embedded fieldbus

ACS550 Users Manual

205

Modbus ref. 10028 10029 10030 10031 10032 10033 10034 10035 10036 10037 10038
1

Internal location (all profiles)


STATUS WORD Bit 27 STATUS WORD Bit 28 STATUS WORD Bit 29 STATUS WORD Bit 30 STATUS WORD Bit 31 DI1 DI2 DI3 DI4 DI5 DI6

ABB DRV

DCU PROFILE

(5305 = 0 OR 2) Reserved Reserved Reserved Reserved Reserved DI1 DI2 DI3 DI4 DI5 DI6

(5305 = 1) REQ_REF1 REQ_REF2 REQ_REF2EXT ACK_STARTINH ACK_OFF_ILCK DI1 DI2 DI3 DI4 DI5 DI6

= Active low

Cho thanh ghi 1xxxx: cc u vo ring bit c thm vo tun t . ACS550 h tr m chc nng sau Modbus cho u vo ring bit :
Function code 02 Description c u vo trng thi

3xxxx Mapping Modbus inputs. Cc phng n bin tn sau y thng tin n a ch 3xxxx Modbus c gi l u vo thanh ghi Modbus : ngi dng n nh bt k u vo tng t. Bng di y tm tc cc u vo thanh ghi:
Modbus reference 30001 30002 ACS550 all profiles
AI1 AI2

Remarks Thanh ghi ny bo co mc ca u vo tng t 1 (0100%). Thanh ghi ny bo co mc ca u vo tng t 2 (0100%).

ACS550 h tr m chc nng sau Modbus cho thanh ghi 3xxxx :


Function code 04 Description c 3xxxx u vo trng thi

4xxxx Register mapping. Phng n bin tn n l tham s v d liu khc n tnh trng thanh ghi 4xxxx nh di y : 4000140099 phng n bin tn kim sot v gi tr thc t . cc thanh ghi c m t trong bng di y . 4010149999 phng n n bin tn tham s 01019999. a ch thanh ghi khng tng ng tham s bin tn l khng hp l. nu c gn c hoc ghi bn ngoi cc a ch tham s , giao din Modbus tr v mt m s ngoi l iu khin .

Embedded fieldbus

206

ACS550 Users Manual

Bng di y tm tc 4xxxx bin tn kim sot thanh ghi 4000140099 (cho 4xxxx thanh ghi trn 40099, xem danh sch tham s bin tn, e.g. 40102 l tham s 0102):
Modbus register 40001
CONTROL WORD

Access R/W

Remarks Phng n trc tip cu hnh CONTROL WORD. Ch c h tr nu 5305 = 0 hoc 2 (ABB Drives profile). Tham s 5319 gi mt bn sao trong nh dng hex . phm vi = 0+20000 ( t l n 01105 REF1 MAX), hoc -200000 (t l n 1105 REF1 MAX0). Phm vi = 0+10000 (t l n 01108 REF2 MAX), hoc -100000 (t l n 1108 REF2 MAX0). Phng n trc tip cu hnh STATUS WORD. Ch c h tr nu 5305 = 0 hoc 2 (ABB Drives profile). Tham s 5320 gi mt bn sao trong nh dng hex. Mc nh, lu tr mt bng sao ca 0103 OUTPUT FREQ. s dng tham s 5310 chn gi tr thc t khc cho thanh ghi ny . Mc nh, lu tr mt bng sao ca 0104 CURRENT. s dng tham s 5311 chn gi tr thc t khc cho thanh ghi ny. Mc nh, khng lu tr. S dng tham s 5312 chn mt gi tr thc t cho thanh ghi . Mc nh, khng lu tr. S dng tham s 5313 chn mt gi tr thc t cho thanh ghi. Mc nh, khng lu tr. S dng tham s 5314 chn mt gi tr thc t cho thanh ghi. Mc nh, khng lu tr. S dng tham s 5315 chn mt gi tr thc t cho thanh ghi. Mc nh, khng lu tr. S dng tham s 5316 chn mt gi tr thc t cho thanh ghi. Mc nh, khng lu tr. S dng tham s 5317 chn mt gi tr thc t cho thanh ghi. Phng n hng n t nht Significant Word ca DCU thng tin CONTROL WORD. Ch c h tr nu 5305 = 1. Xem tham s 0301. Phng n hng n nhiu nht Significant Word ca DCU thng tin CONTROL WORD. Ch c h tr nu 5305 = 1. Xem tham s 0302. Phng n hng n t nht Significant Word ca DCU thng tin CONTROL WORD. Ch c h tr nu 5305 = 1. Xem tham s 0303. Phng n hng n nhiu nht Significant Word ca DCU thng tin CONTROL WORD. Ch c h tr nu 5305 = 1 Xem tham s 0304.

40002 40003 40004

Reference 1 Reference 2
STATUS WORD

R/W R/W R

40005

Actual 1 (select using 5310) Actual 2 (select using 5311) Actual 3 (select using 5312) Actual 4 (select using 5313) Actual 5 (select using 5314) Actual 6 (select using 5315) Actual 7 (select using 5316) Actual 8 (select using 5317) ACS550 CONTROL WORD LSW ACS550 CONTROL WORD MSW ACS550 STATUS WORD LSW ACS550 STATUS WORD MSW

40006 40007 40008 40009 40010 40011 40012 40031

R R R R R R R R/W

40032

40033

40034

Embedded fieldbus

ACS550 Users Manual

207

i vi cc giao thc Modbus, tham s bin tn trong nhm 53: EFB PROTOCOL bo co phng n tham s 4xxxx thanh ghi .
Code 5310 EFB PAR 10 Ch nh phng n tham s n Modbus thanh ghi 40005. 5311 EFB PAR 11 Ch nh phng n tham s n Modbus thanh ghi 40006. 5312 EFB PAR 12 Ch nh phng n tham s n Modbus thanh ghi 40007. 5313 EFB PAR 13 Ch nh phng n tham s n Modbus thanh ghi 40008. 5314 EFB PAR 14 Ch nh phng n tham s n Modbus thanh ghi 40009. 5315 EFB PAR 15 Ch nh phng n tham s n Modbus thanh ghi 40010. 5316 EFB PAR 16 Ch nh phng n tham s n Modbus thanh ghi 40011. 5317 EFB PAR 17 Ch nh phng n tham s n Modbus thanh ghi 40012. 5318 EFB PAR 18 Thit lp thm b tr trong milli giy trc khi ACS550 bt u Truyn p ng yu cu tng th . 5319 EFB PAR 19 Gi mt bn sao (trong hex) ca CONTROL WORD, Modbus thanh ghi 40001. 5320 EFB PAR 20 Gi mt bn sao (trong hex) ca STATUS WORD, Modbus thanh ghi 40004. Description

Tr trng hp b gii hn bi bin tn, tt c cc thng s c sn cho c c v vit. tham s vit c xc minh cho gi tr chnh xc v cho mt a ch thanh ghi hp l . ch : tham s vit thng qua tiu chun Modbus l lun lun thay i c i.e. thay i gi tr l khng t ng lu vo b nh vnh vin. S dng tham s 1607 PARAM SAVE lu tt c cc gi tr thay i. ACS550 h tr m chc nng Modbus sau y cho thanh ghi 4xxxx :
Function code 03 06 16 (0x10 Hex) 23 (0x17 Hex) Description Read holding 4xxxx registers Preset single 4xxxx register Preset multiple 4xxxx registers Read/write 4xxxx registers

Embedded fieldbus

208

ACS550 Users Manual

Gi tr thc t Ni dung ca a ch thanh ghi 4000540012 l GI TR THC T v l: quy nh c th bng cch s dng cc thng s 53105317 . ch c gi tr c cha thng tin v hot ng ca bin tn . 16-bit words c cha bit duy nht v mt s nguyn 15-bit khi gi tr m, vit nh hai b sung ca gi tr dng tng ng t l nh m t trc trong phn t l thc t trn trang 197. M ngoi l M ngoi l l nhy giao tip ni tip t bin tn. ACS550 h tr m ngoi l tiu chun Modbus c xc nh bn di .
Exception code 01 02 03 Name ILLEGAL FUNCTION ILLEGAL DATA ADDRESS ILLEGAL DATA VALUE Khng h tr lnh a ch d liu nhn c trong yu cu l khng cho php. N khng xc nh c tham s/nhm . Gi tr cha trong trng d liu yu cu l khng cho php gi tr cho ACS550, bi v n l mt trong nhng iu sau y : Outside min. or max. limits. thng s l ch c. thng bo l qu di. cc tham s ghi khng c php khi bt u hot ng. cc tham s ghi khng c php khi macro factory c chn. Meaning

Embedded fieldbus

ACS550 Users Manual

209

ABB control profiles technical data


Overview ABB Drives profile ABB Drives h tr cung cp mt h tr tiu chun c th c s dng trn nhiu giao thc , bao gm Modbus v cc giao thc c sn trn FBA module. Hai ci t h tr ABB Drives l c sn : ABB DRV FULL ci t tiu chun ny giao din iu khin vi bin tn ACS600 v ACS800. ABB DRV LIM ci t tiu chun ny giao din iu khin vi bin tn ACS400. ci t ny khng h tr hai kim sot word bits h tr bi ABB DRV FULL. Ngoi nh nu, sau y ABB Drives Profile m t vic ci t cho c hai . DCU profile DCU thng tin m rng kim sot v trng thi giao din 32 bits. N l giao din ni b gia ng dng chnh ca bin tn v t vo mi trng fieldbus . Control Word
CONTROL WORD l

bin php ch yu iu khin bin tn t mt h thng fieldbus . Trm ch fieldbus gi CONTROL WORD n bin tn . Bin tn chuyn i gia trng thi ph hp n bit-m hng dn trong CONTROL WORD. Bng cch s dng CONTROL WORD yu cu l : bin tn l trong kim sot t xa (REM) . cc knh truyn thng ni tip c xc nh nh ngun cho lnh iu khin (thit lp bng cch s dng tham s nh 1001 EXT1 COMMANDS, 1002 EXT2 COMMANDS v 1102 EXT1/EXT2 SEL). cc knh truyn thng ni tip c s dng cu hnh s dng mt cu hnh iu khin ABB. V d , s dng thng tin kim sot ABB DRV FULL i hi c hai tham s 9802 COMM PROT SEL = 1 (STD MODBUS) v tham s 5305 EFB CTRL PROFILE = 2 (ABB DRV FULL).

Embedded fieldbus

210

ACS550 Users Manual

ABB Drives profile Bng sau y v s trng thi sau ny trong phn nh ny m t kt ni CONTROL WORD cho thng tin ABB Drives .
ABB Drives profile CONTROL WORD (xem tham s 5319) Bit 0 Name OFF1 CONTROL Value 1 0 Commanded state Comments

READY TO OPERATE Nhp READY TO OPERATE EMERGENCY OFF Bin tn dng theo dc n hot ng hin ti ca dc gim tc (2203 hoc 2205) chui lnh bnh thng : nhp OFF1 ACTIVE tip tc n READY TO SWITCH ON, tr khi kha lin ng khc (OFF2, OFF3) ang hot ng .

OFF2 CONTROL

1 0

OPERATING EMERGENCY OFF

tip tc hot ng (OFF2 khng hot ng) Bin tn dng theo qun tnh . Chui lnh bnh thng: nhp OFF2 ACTIVE tip tc n SWITCHON INHIBITED

OFF3 CONTROL

1 0

OPERATING EMERGENCY STOP

tip tc hot ng (OFF3 khng hot ng) bin tn dng trong thi gian quy nh bi tham s 2208. chui lnh bnh thng: nhp OFF3 ACTIVE lin tc n SWITCH ON INHIBITED Cnh bo! Chc chn ng c v thit b iu khin khc dng li bng cch s dng ch ny .

INHIBIT OPERATION

OPERATION ENABLED

Nhp OPERATION ENABLED (ch tn hiu cho php chy phi hot ng . Xem 1601. nu 1601 l t n COMM, bit ny cng hot ng tn hiu kch hot chy .) c ch hot ng. nhp OPERATION INHIBITED

0 4 Unused ( ABB DRV LIM) RAMP_OUT_ ZERO (ABB DRV FULL) 1 0

OPERATION INHIBITED

NORMAL OPERATION RFG OUT ZERO

Nhp RAMP FUNCTION GENERATOR: ACCELERATION ENABLED Chc nng dc lc pht in u ra cho khng . bin tn dng theo dc (dng in v gii hn in p DC trong lc ). Kch hot chc nng dc . Nhp RAMP FUNCTION GENERATOR: ACCELERATOR ENABLED Dng dc (chc nng dc pht in u ra t chc )

RAMP_HOLD

RFG OUT ENABLED

0 6 RAMP_IN_ ZERO 1 0

RFG OUT HOLD

RFG INPUT ENABLED hot ng bnh thng. nhp OPERATING

RFG INPUT ZERO

chc nng lc dc pht in u ra n khng.

Embedded fieldbus

ACS550 Users Manual

211

ABB Drives profile CONTROL WORD (See parameter 5319) Bit 7 Name RESET Value 0=>1 Commanded state RESET Comments Li reset nu hot ng li vn tn ti (nhp SWITCH-ON INHIBITED). Hiu qu nu 1604 = COMM. Tip tc hot ng bnh thng

0 89 Unused 10 Unused ( ABB DRV LIM) REMOTE_CMD (ABB DRV FULL) 1 0

OPERATING

Fieldbus cho php kim sot. CW = 0/ or Ref = 0: /Retain last CW and Ref. CW = 0 and Ref = 0: Fieldbus cho php Kim sot. tham chiu v dc gim tc/tng tc c kha .

11

EXT CTRL LOC

1 0

EXT2 SELECT EXT1 SELECT

Chn im kim sot bn ngoi 2 (EXT2). Hiu qu nu 1102 = COMM. Chn im kim sot bn ngoi 1 (EXT1). Hiu qu nu 1102 = COMM.

12 15

cha s dng

DCU Profile Bng sau y m t cc kt ni CONTROL WORD cho thng tin DCU .
DCU profile CONTROL WORD (See parameter 0301) Bit 0 STOP Name Value 1 0 1 START 1 0 2 REVERSE 1 0 3 LOCAL 1 0 4 RESET -> 1 other 5 EXT2 1 0 6 RUN_DISABLE 1 0 7 STPMODE_R 1 0 Command/Req. Stop (no op) Start (no op) Reverse direction Forward direction Local mode External mode Reset (no op) Switch to EXT2 Switch to EXT1 Run disable Run enable on Normal ramp stop mode (no op) Ngc , cho php chy. Comments Dng theo ch tham s hoc dng theo ch cu hnh (bits 7 v 8). ng thi lnh STOP v START kt qu l mt lnh dng . Bit ny XORd vi tn hiu ca tham chiu xc nh hng . Khi thit lp fieldbus ny bit, n ly i kim sot v bin tn di chuyn n fieldbus ch kim sot cc b. Edge sensitive.

Embedded fieldbus

212

ACS550 Users Manual

DCU profile CONTROL WORD (See parameter 0301) Bit 8 Name STPMODE_EM Value 1 0 9 STPMODE_C 1 0 10 RAMP_2 1 0 11 RAMP_OUT_0 1 0 12 RAMP_HOLD 1 0 13 RAMP_IN_0 1 0 14 RREQ_LOCALL OC TORQLIM2 1 0 1 0 Command/Req. Emergency ramp stop mode (no op) Coast stop mode (no op) Ramp pair 2 Ramp pair 1 Ramp output to 0 (no op) Ramp freeze (no op) Ramp input to 0 (no op) Local mode lock (no op) Torque limit pair 2 Torque limit pair 1 Trong kha , bin tn s khng chuyn sang ch cc b. Comments

15

DCU profile CONTROL WORD (See parameter 0302) Bit 1626 27 REF_CONST 1 0 28 REF_AVE 1 0 29 LINK_ON 1 0 30 REQ_STARTINH 1 0 31 OFF_INTERLOCK 1 0 Name Value Function Reserved Constant speed ref. (no op) Average speed ref. (no op) Master is detected in link Link is down Start inhibit request is pending Start inhibit request is OFF Panel OFF button pressed (no op) i vi bng iu khin (hoc cng c PC) y l nt OFF ca kha lin ng. nhng bits ny ch dnh cho mc ch gim st . Comments

Status Word Ni dung ca STATUS WORD l trng thi thng tin, gi bi bin tn n trm ch .

Embedded fieldbus

ACS550 Users Manual

213

ABB Drives profile Bng sau y v s trng thi trong phn nh ny m t cc kt ni STATUS WORD cho thng tin ABB Drives.
ABB Drives profile (EFB) STATUS WORD (See parameter 5320) Bit 0 Name RDY_ON Value 1 0 1 RDY_RUN 1 0 2 RDY_REF 1 0 3 TRIPPED 01 0 4 OFF_2_STA 1 0 5 OFF_3_STA 1 0 6 SWC_ON_INHIB 1 0 7 ALARM 1 0 8 AT_SETPOINT 1 0 9 REMOTE 1 0 10 ABOVE_LIMIT 1 Description (Correspond to states/boxes in the state diagram) READY TO SWITCH ON NOT READY TO SWITCH ON READY TO OPERATE OFF1 ACTIVE OPERATION ENABLED OPERATION INHIBITED FAULT No fault OFF2 INACTIVE OFF2 ACTIVE OFF3 INACTIVE OFF3 ACTIVE SWITCH-ON INHIBIT ACTIVE SWITCH-ON INHIBIT NOT ACTIVE Bo ng (xem phn Alarm listing trn trang 250 cho hng dn chi tit bo ng.) Khng bo ng OPERATING. Gi tr thc t bng (gii hn dung sai) gi tr tham chiu . Gi tr thc t ngoi gii hn chiu ng (khng bng gi tr tham chiu). v tr kim sot bin tn: REMOTE (EXT1 hoc EXT2) v tr kim sot bin tn: LOCAL Gi tr tham s gim st > gii hn gim st cao . Bit vn cn 1 n khi gi tr tham s gim st < gii hn gim st thp. xem nhm 32: SUPERVISION. 0 Gi tr tham s gim st < gii hn gim st thp. Bit vn cn 0 n khi gi tr tham s gim st > gii hn gim st cao. xem nhm 32: SUPERVISION. 11 EXT CTRL LOC 1 0 12 EXT RUN ENABLE 1 0 13 15 Cha s dng Chn v tr kim sot ngoi 2 (EXT2) Chn v tr kim sot ngoi 1 (EXT1) Nhn c tn hiu Run Enable bn ngoi Khng nhn c tn hiu Run Enable bn ngoi

Embedded fieldbus

214

ACS550 Users Manual

DCU profile Bng sau y m t kt ni STATUS WORD cho thng tin DCU .
DCU profile STATUS WORD (See parameter 0303) Bit 0 Name READY Value 1 0 1 ENABLED 1 0 2 STARTED 1 0 3 RUNNING 1 0 4 ZERO_SPEED 1 0 5 ACCELERATE 1 0 6 DECELERATE 1 0 7 AT_SETPOINT 1 0 8 LIMIT 1 0 9 SUPERVISION 1 0 10 REV_REF 1 0 11 REV_ACT 1 0 12 PANEL_LOCAL 1 0 13 FIELDBUS_LOCAL 1 0 14 EXT2_ACT 1 0 15 FAULT 1 0 Status Bin tn sn sng nhn lnh khi ng. Bin tn khng sn sng. Nhn c tn hiu cho php chy bn ngoi. Khng nhn c tn hiu cho php chy bn ngoi. Bin tn nhn c lnh khi ng. Bin tn khng nhn c lnh khi ng. Bin tn l iu bin. Bin tn khng iu bin. Bin tn l tc khng . Bin tn khng t c tc khng . Bin tn ang tng tc. Bin tn khng tng tc. Bin tn ang gim tc . Bin tn khng gim tc. Bin tn ti im t. Bin tn khng t c im t. Hot ng b gii hn bi ci t nhm 20: LIMITS. Hot ng nm trong ci t nhm 20: LIMITS . Mt tham s gim st (nhm 32: SUPERVISION) l bn ngoi gii hn ca n. Tt c tham s gim st nm trong gii hn . Tham chiu bin tn l theo hng ngc li. Tham chiu bin tn l theo hng thun . Bin tn ang chy theo hng ngc li . Bin tn ang chy theo hng thun . Kim sot l ch kim sot bng iu khin cc b (hoc cng c PC). Kim sot l khng ch kim sot bng iu khin cc b. Kim sot l trong ch cc b fieldbus (ly i bng iu khin cc b ). Kim sot l khng trong ch cc b fieldbus. Kim sot l trong ch EXT2. Kim sot l trong ch EXT1. Bin tn l trong trng thi li. Bin tn l khng trong trng thi li.

Embedded fieldbus

ACS550 Users Manual

215

DCU profile STATUS WORD (See parameter 0304) Bit 16 Name ALARM Value 1 0 17 REQ_MAINT 1 0 18 DIRLOCK 1 0 19 LOCALLOCK 1 0 20 CTL_MODE 1 0 2125 26 REQ_CTL 1 0 27 REQ_REF1 1 0 28 REQ_REF2 1 0 29 REQ_REF2EXT 1 0 30 ACK_STARTINH 1 0 31 ACK_OFF_ILCK 1 0 Mt bo ng l on. Khng bo ng l on. Mt yu cu bo tr l tr hon. Khng yu cu bo tr l tr hon. Hng kha l ON. (hng thay i kha u ra .) Hng kha l OFF. Kha ch cc b l ON. (ch cc b b kha u ra .) Kha ch cc b l OFF. Bin tn l trong ch kim sot vector. Bin tn l trong ch kim sot v hng. Ngc li Sao chp kim sot word (no op) Yu cu tham chiu 1 trong chng ny. Yu cu tham chiu 1 l khng trong chng ny. Yu cu tham chiu 2 trong chng ny. Yu cu tham chiu 2 l khng trong chng ny. Tham chiu bn ngoi PID 2 yu cu trong chng ny. Tham chiu bn ngoi PID 2 khng yu cu trong chng ny. Mt c ch khi ng t chng ny l c cp . Mt c ch khi ng t chng ny l khng c cp. c ch khi ng do nt OFF hot ng bnh thng . Status

Embedded fieldbus

216

ACS550 Users Manual

State diagram ABB Drives profile minh ha hot ng ca s trng thi, v d sau (ABB DRV LIM thc hin ca thng tin ABB Drives ) s dng kim sot word khi ng bin tn : u tin, yu cu cho s dng CONTROL WORD phi c p ng. xem trn . khi in nng l kt ni u tin, trng thi ca bin tn l khng sn sng chuyn i on. Xem chm ng dn ( ) trong s trng thi di y . s dng CONTROL WORD bc thng qua trng thi my n khi trng thi OPERATING trng thi l t c , c ngha l bin tn ang chy v sau cc tham chiu cho. Xem bng di y .
Step 1 CONTROL WORD Value CW = 0000 0000 0000 0110 bit 15 2 3 4 5 CW = 0000 0000 0000 0111 CW = 0000 0000 0000 1111 CW = 0000 0000 0010 1111 bit 0 Description CW ny c gi tr thay i trng thi bin tn n READY TO SWITCH ON. Ch t nht 100 ms trc khi tip tc . CW ny c gi tr thay i trng thi bin tn n READY TO OPERATE. CW ny c gi tr thay i trng thi bin tn n OPERATION ENABLED.Bin tn khi ng, nhng s khng tng tc. CW ny c gi tr tham chiu dc chc nng my pht (RFG) u ra v thay i trng thi bin tn n RFG: ACCELERATOR ENABLED. CW ny c gi tr tham chiu dc chc nng my pht (RFG) u ra v thay i trng thi bin tn n OPERATING. Bin tn tng tc n tham chiu trc v sau tham chiu .

CW = 0000 0000 0110 1111

Embedded fieldbus

ACS550 Users Manual

217

S trng thi di y m t chc nng khi ng- dng ca CONTROL WORD (CW) v STATUS WORD (SW) bits cho thng tin ABB Drives .
T bt k trng thi Dng khn cp OFF3 (CW Bit2=0) (SW Bit5=0) OFF3 ACTIVE OFF2 ACTIVE T bt k trng thi Dng khn cp tc OFF2 (CW Bit1=0) (SW Bit4=0) T bt k trng thi Li FAULT (SW Bit3=1) (CW Bit7=1)**

n(f)=0 / I=0 T bt k trng thi OFF1 (CW Bit0=0) (SW Bit1=0) n(f)=0 / I=0 OFF1 ACTIVE MAINS OFF Power ON

SWITCH-ON INHIBITED

(SW Bit6=1)

(CW Bit0=0)

A B* C D

NOT READY TO SWITCH ON

(SW Bit0=0)

(CW Bit3=0) (SW Bit2=0) OPERATION INHIBITED

(CW xxxx x1xx xxxx x110) READY TO SWITCH ON (SW Bit0=1)

OPERATION INHIBITED

(CW= xxxx x1xx xxxx x111) B* C* D*

READY TO OPERATE

(SW Bit1=1)

(CW Bit4=0)*

(CW Bit3=1 and SW Bit12=1) OPERATION ENABLED A

CD (CW Bit5=0)

(SW Bit2=1)

(CW=xxxx x1xx xxx1* 1111 i.e. Bit 4=1)* RFG OUTPUT ENABLED* B* (CW=xxxx x1xx xx11* 1111 i.e. Bit 5=1) RFG: ACCELERATOR ENABLED C (CW=xxxx x1xx x111* 1111 i.e. Bit 6=1) OPERATING D (SW Bit8=1)

KEY Trng thi Thay i trng thi ng dn mo t trong v d CW = CONTROL WORD SW = STATUS WORD RFG = chc nng dc my pht I = Param. 0104 CURRENT f = Param. 0103 OUTPUT FREQ n = tc * ch ra tnh nng khng trong ABB DRV LIM ** chuyn i trng thi ny cng xy ra nu li l reset t bt k ngun khc (e.g. u vo s ). (CW Bit6=0) D

Embedded fieldbus

218

ACS550 Users Manual

Reference scaling ABB Drives and DCU profiles Bng di y m t t l THAM CHIU cho ABB Drives v thng tin DCU .
ABB Drives and DCU profiles Reference REF1 Range -32767 +32767 Reference type tc hoc tn s Scaling -20000 = -(par. 1105) 0=0 +20000 = (par. 1105) (20000 corresponds to 100%) REF2 -32767 +32767 -10000 = -(par. 1108) 0=0 +10000 = (par. 1108) (10000 corresponds to 100%) momen xon -10000 = -(par. 1108) 0=0 +10000 = (par. 1108) (10000 corresponds to 100%) PID Tham chiu -10000 = -(par. 1108) 0=0 +10000 = (par. 1108) (10000 corresponds to 100%) Tham chiu cui cng c gii hn bi 4012/4013 (PID set1) hoc 4112/4113 (PID set2). Remarks Tham chiu cui cng c gii hn bi 1104/1105. Tc thc t ng c gii hn bi 2001/2002 (tc ) hoc 2007/2008 (tn s ). Tham chiu cui cng c gii hn bi 1107/1108. tc thc t ng c c gii hn bi 2001/ 2002 (tc ) hoc 2007/2008 (tn s ). Tham chiu cui cng c gii hn bi 2015/2017(momen xon 1) hoc 2016/2018 (momen xon 2).

tc hoc tn s

Ch : ci t cc tham s 1104 REF1 MIN v 1107 REF2 MIN khng c tc dng vi t l ca tham chiu . Khi tham s 1103 REF1 SELECT hoc 1106 REF2 SELECT c t n COMM+AI1 hoc COMM*AI1, tham chiu l t l nh bn di :
ABB Drives and DCU profiles Reference REF1 Value setting
COMM+AI1 COMM

AI reference scaling (%) +(AI (%) - 0.5 REF1 MAX (%)) Tham chiu Fieldbus hiu chnh h s (100 + 0.5 (Par. 1105)%

100%

AI1 u vo tn hiu (100 - 0.5 (par. 1105))% 0% 50% 100%

Embedded fieldbus

ACS550 Users Manual

219

ABB Drives and DCU profiles Reference REF1 Value setting


COMM*AI1 COMM

AI reference scaling (%) (AI (%) / 0.5 REF1 MAX (%)) Tham chiu Fieldbus hiu chnh h s 200%

100%

AI1 u vo tn hiu (100 - 0.5 (par. 1105))% REF2


COMM+AI1

0%

50%

100%

COMM

(%) + (AI (%) - 0.5 REF2 MAX (%)) Tham chiu Fieldbus hiu chnh h s (100 + 0.5 (Par. 1108)%

100%

AI1 u vo tn hiu (100 - 0.5 (par. 1108)% REF2


COMM*AI1

0%

50%

100%

COMM

(%) (AI (%) / 0.5 REF2 MAX (%)) Tham chiu Fieldbus hiu chnh h s 200%

100%

AI1 u vo tn hiu 0% 0% 50% 100%

Embedded fieldbus

220

ACS550 Users Manual

Reference handling S dng nhm 10: START/STOP/DIR tham s cu hnh cho kim sot hng quay cho mi v tr kim sot (EXT1 v EXT2). Cc s sau y m t lm th no 10 nhm tham s v k hiu ca tham chiu fieldbus tng tc to ra gi tr THAM CHIU (REF1 v REF2). Ch , tham chiu fieldbus l lng cc, ngha l n c th dng hoc m .
ABB Drives profile Parameter 1003 DIRECTION Value setting 1 (FORWARD) Max. ref T l tham chiu AI Resultant ref.

Fieldbus reference

-163% -100%

100% 163%

-(Max. ref.) 1003 DIRECTION 2 (REVERSE) Max. ref Resultant ref. Fieldbus reference -163% -100% 100% 163%

-(Max. ref.) 1003 DIRECTION 3 (REQUEST) Max. ref Resultant ref.

Fieldbus reference

-163% -100% 100% 163%

-(Max. ref.)

Embedded fieldbus

ACS550 Users Manual

221

Fieldbus adapter

Overview
ACS550 c th thit lp chp nhn kim sot t mt h thng bn ngoi bng cch s dng chun giao thc giao tip ni tip . Khi s dng giao tip ni tip, ACS550 c th khc : nhn c tt c cc thng tin kim sot t fieldbus, hoc c iu khin t mt s h thng ca kim sot fieldbus v v tr kim sot c sn khc, chng hn nh u vo s hoc tng t v bng iu khin .
B iu khin Fieldbus Fieldbus

Thit b khc

S dng kt ni khc : t vo fieldbus tiu chun (EFB) ti u ni X1:2832 b chuyn i fieldbus (FBA) module c gn trong khe cm 2 (ty chn Rxxx)

Hai cu hnh truyn thng ni tip c bn l c sn : t vo fieldbus (EFB) xem chng Embedded fieldbus trn trang 189. b chuyn i fieldbus (FBA) vi mt ty chn FBA modules trong khe cm m rng 2 ca bin tn , bin tn c th giao tip vi mt h thng iu khin bng cch s dng mt trong cc giao thc sau y : Profibus-DP LonWorks CANopen DeviceNet ControlNet. ACS550 t ng pht hin vi giao thc giao tip c s dng bi php vo b chuyn i fieldbus. Ci t mc nh cho mi giao thc gi nh rng thng tin c s dng l chun giao thc cng ngh thng tin bin tn (e.g. PROFI bin tn cho PROFIBUS, AC/DC bin tn cho DeviceNet). Tt c cc giao thc FBA cng c th cu hnh cho thng tin ABB Drives . cu hnh chi tit ph thuc vo giao thc v s dng giao thc. bit thm chi tit c cung cp trong hng dn s dng vi cc FBA module. Chi tit cho thng tin ABB Drives (p dng cho tt c cc giao thc) c cung cp trong phn ABB Drives profile technical data trn trang 232.

Fieldbus adapter

222

ACS550 Users Manual

Control interface Ni chung, giao din iu khin c bn gia h thng fieldbus v bin tn bao gm: u ra Words: CONTROL WORD REFERENCE (tc hoc tn s) khc : bin tn h tr nhiu nht 15 u ra words. Gii hn giao thc c th hn ch tng s u ra. u vo Words: STATUS WORD gi tr thc t (tc hoc tn s) khc : bin tn h tr nhiu nht 15 u vo words. Gii hn giao thc c th hn ch tng s u ra. Ch : word u ra v u vo c s dng ly t im iu khin fieldbus ca xem. V d mt dng u ra d liu m t t iu khin fieldbus n bin tn v xut hin nh mt u vo t im bin tn ca xem . ngha ca giao din iu khin words l khng gii hn bi ACS550. Tuy nhin, thng tin s dng c th thit lp ngha c bit .
B iu khin Fieldbus Fieldbus Control Word (CW) Tham chiu Status Word (SW) Gi tr thc t

Process I/O (cyclic)

Service Messages (Acyclic)

Tham s R/W Requests/Responses

Control Word
CONTROL WORD l

phng thc chnh cho iu khin bin tn t mt h thng fieldbus. B iu khin fieldbus gi CONTROL WORD n bin tn. Bin tn chuyn i gia trng thi ph hp n hng dn m bit- trong CONTROL WORD. Bng cch s dng CONTROL WORD yu cu : bin tn trong kim sot t xa (REM) . cc knh truyn thng ni tip c xc nh nh ngun cho lnh iu khin T EXT1 (thit lp bng cch s dng tham s 1001 EXT1 COMMANDS v 1102 EXT1/EXT2 SEL). ghp vo b chuyn i fieldbus bn ngoi c kch hot:

Fieldbus adapter

ACS550 Users Manual

223

tham s 9802 COMM PROT SEL = 4 (EXT FBA). ghp vo b chuyn i fieldbus bn ngoi c cu hnh s dng ch thng tin bin tn hoc thng tin i tng bin tn. dung lng ca CONTROL WORD ph thuc vo giao thc/thng tin s dng. xem hng dn s dng cung cp vi FBA module v/hoc chn ABB Drives profile technical data trn trang 232. Status Word
STATUS WORD l

word 16-bit c cha thng tin trng thi, gi bi bin tn n b iu khin fieldbus. Dung lng ca STATUS WORD ph thuc vo giao thc/thng tin s dng. Xem hng dn s dng cung cp vi FBA module v/hoc chn ABB Drives profile technical data trn trang 232. Reference Dung lng ca mi REFERENCE word: c th s dng, nh tc hoc tn s tham chiu . l word 16-bit bao gm 1 bit k hiu v 15-bit nguyn . tham chiu m (ch hng quay ngc li) c ch nh bi b sung hai gi tr tham chiu dng tng ng . Vic s dng tham chiu th hai (REF2) c h tr ch khi mt giao thc l c cu hnh cho thng tin ABB Drives . T l tham chiu l loi fieldbus c th. Xem hng dn s dng c cung cp vi FBA module v/hoc phn sau y cho ph hp : Reference scaling trn trang 236 (ABB Drives profile technical data) Reference scaling trn trang 240 (Generic profile technical data). Actual Values Gi tr thc t l words 16-bit c cha thng tin trn chn hot ng ca bin tn . gi tr thc t bin tn (v d, nhm 10: START/STOP/DIR tham s ) phng n c th Words bng cch s dng nhm 51: EXT COMM MODULE tham s (giao thc ph thuc, nhng cc thng s thng thng 51045126).

Planning
Quy hoch mng li a ch vi cc cu hi sau y : loi v s lng cc thit b phi c kt ni vo mng ? kim sot thng tin phi c gi xung n bin tn ? thng tin phn hi phi c gi t bin tn n h thng iu khin ?

Fieldbus adapter

224

ACS550 Users Manual

Mechanical and electrical installation FBA


Cnh bo! Kt ni c thc hin ch khi bin tn c ngt kt ni t ngun in. Overview FBA (b chuyn i fieldbus) l ghp vo module ph hp trong khe cm m rng 2 ca bin tn . module l t chc ti im vi v nha gi li v hai vt. Cc vt cng ni t cho cp l chn module v kt ni tn hiu module GND n board kim sot bin tn . trn h thng ca kt ni module, in n bin tn l t ng thit lp thng qua kt ni u ni 34-pin. Mounting procedure
1

Ch : lp t u vo ngun in v cp ng c u tin . 1. chn module mt cch cn thn vo khe cm m rng 2 ca bin tn cho n khi kha ghim gi module vo v tr. 2. vn cht hai c vt (included) n dng li . Ch : lp t ng cc c vt l cn thit cho thc hin yu cu EMC v hot ng ng ca module . .
7 2

3. m tch ra thch hp trong hp chia dy v lp t u kp cp cho cp mng. 4. nh v mng cp thng qua u kp cp. 5. kt ni mng cp kt ni mng ca module . 6. sit cht cc u kp cp . 7. lp t hp ng dn bao gm (1 vt ). 8. cho thng tin cu hnh xem di y : phn Communication set-up FBA trn trang 225 phn Activate drive control functions FBA trn trang 225 giao thc cung cp c trng ring vi module.

X00301

5 6 3 4
X00302

Fieldbus adapter

ACS550 Users Manual

225

Communication set-up FBA


Serial communication selection kch hot giao tip ni tip, s dng tham s 9802 COMM PROT SEL. Thit lp 9802 = 4 (EXT FBA). Serial communication configuration Thit lp 9802, cng vi trang b mt FBA module ring bit, t ng thit lp cc gi tr mc nh thch hp trong tham s xc nh qu trnh truyn thng. Cc tham s v m t c xc nh trong hng dn s dng cung cp vi FBA module. tham s 5101 l t ng cu hnh. tham s 51025126 l giao thc ph thuc v xc nh, v d, thng tin s dng v b sung word I/O. Cc tham s ny c gi l cc tham s cu hnh fieldbus. Xem hng dn s dng cung cp vi FBA module cho chi tit trn tham s cu hnh fieldbus. tham s 5127 lc thay i ph hp n tham s 51025126. nu tham s 5127 l khng c s dng , thay i n tham s 51025126 ch nh hng n sau khi ngun in bin tn l chu k . tham s 51285133 cung cp d liu cc module FBA lp t hin thi (e.g. cc phn phin bn v trng thi ). xem nhm 51: EXT COMM MODULE cho m t tham s.

Activate drive control functions FBA


Kim sot Fieldbus ca cc chc nng khc nhau bin tn i hi cu hnh n : bo cho bin tn chp nhn chc nng kim sot fieldbus xc nh nh mt u vo fieldbus , bt k d liu iu khin theo yu cu cho iu khin xc nh nh mt u ra fieldbus , bt k d liu iu khin theo yu cu ca bin tn. Phn sau y m t , mc chung , cu hnh cn thit cho mi chc nng kim sot. Ct cui cng trong mi bng di y l c tnh trng. Xem hng dn s dng cung cp vi FBA module cho nhp vo thch hp. Start/Stop Direction control S dng fieldbus cho khi ng/dng/kim sot hng ca bin tn yu cu : gi tr tham s bin tn t nh mc nh sau y b iu khin fieldbus cung cp lnh(s) v tr thch hp. (v tr xc nh bi giao thc tham chiu, l giao thc ph thuc.)
Drive parameter 1001
EXT1 COMMANDS

Value 10 (COMM)

Description iu khin khi ng / dng bi fieldbus vi Chn Ext1.

Protocol reference

Fieldbus adapter

226

ACS550 Users Manual

Drive parameter 1002 1003


EXT2 COMMANDS DIRECTION

Value 10 (COMM) 3 (REQUEST)

Description iu khin khi ng / dng bi fieldbus vi chn Ext2. fieldbus.

Protocol reference

chn u vo tham chiu s dng fieldbus cung cp u vo tham chiu n bin tn yu cu : gi tr tham s bin tn t nh mc nh sau y . b iu khin fieldbus cung cp tham chiu word(s) v tr thch hp . (v tr c xc nh bi giao thc tham chiu, l giao thc phu thuc.)
Drive parameter 1102 1103 EXT1/EXT2 SEL REF1 SELECT Value 8 (COMM) 8 (COMM) 9 (COMM+AI1) 10 (COMM*AI1) 8 (COMM) 9 (COMM+AI) 10 (COMM*AI) Description Ref. chn bi fieldbus. (Required only if 2 references used.) u vo tham chiu 1 c cung cp bi fieldbus. u vo tham chiu 2 c cung cp bi fieldbus. (bt but ch khi tham chiu 2 c s dng.) Protocol reference

1106

REF2 SELECT

Ch : nhiu tham chiu c h tr ch khi s dng thng tin ABB Drives. T l Khi cn thit, THAM CHIU c th c thu nh li. xem phn sau, nh trng hp : Reference scaling trn trang 236 (ABB Drives profile technical data) Reference scaling trn trang 240 (Generic profile technical data). System control S dng fieldbus cho bin tn kim sot hn hp yu cu : gi tr tham s bin tn t nh mc nh sau y . b iu khin lnh fieldbus (s) v tr thch hp. (v tr ny c xc nh bi giao thc tham chiu, l giao thc phu thuc.)
Drive parameter 1601 1604 1607
RUN ENABLE FAULT RESET SEL PARAM SAVE

Value 7 (COMM) 8 (COMM) 1 (SAVE)

Description cho php chy bi fieldbus. li reset bi fieldbus. Lu thay i thng s vo b nh (sau gi tr tr v 0).

Protocol reference

Fieldbus adapter

ACS550 Users Manual

227

Relay output control S dng fieldbus cho kim sot u ra relay yu cu : gi tr tham s bin tn t nh mc nh sau y b iu khin fieldbus cung cp, m nh phn, lnh relay (s) v tr thch hp . (v tr ny c xc nh bi giao thc tham chiu, l giao thc ph thuc.)
Protocol reference

Drive parameter 1401 1402 1403 14101 14111 14121


1

Value 35 (COMM) 36 (COMM(-1))

Description Relay Output 1 controlled by fieldbus. Relay Output 2 controlled by fieldbus. Relay Output 3 controlled by fieldbus. Relay Output 4 controlled by fieldbus. Relay Output 5 controlled by fieldbus. Relay Output 6 controlled by fieldbus.

RELAY OUTPUT 1 RELAY OUTPUT 2 RELAY OUTPUT 3 RELAY OUTPUT 4 RELAY OUTPUT 5 RELAY OUTPUT 6

Nhiu hn 3 relays i hi b sung mt module relay m rng .

Ch : Relay tnh trng thng tin phn hi m khng cn cu hnh nh di y .


Drive parameter 0122 0123
RO 1-3 STATUS RO 4-6 STATUS

Value Relay 13 status. Relay 46 status.

Protocol reference

Analog output control S dng fieldbus cho u vo tng t kim sot (e.g. im t PID) yu cu : gi tr tham s bin tn t nh mc nh sau y . b iu khin fieldbus cung cp gi tr tng t(s) v tr thch hp . (v tr ny c xc nh bi giao thc tham chiu, l giao thc ph thuc.)
Drive parameter 1501 0135 1502 1505 1506 1507 0136 1508 1511 1512
AO1 CONTENT SEL COMM VALUE

Value 135 (COMM VALUE 1) Set appropriate values.

Description Analog Output 1 controlled by writing to parameter 0135. Used for scaling

Protocol reference

AO1 CONTENT MIN

MAXIMUM AO1 FILTER AO1 AO2 CONTENT SEL COMM VALUE

Filter time constant for AO1. 136 (COMM VALUE 2) Set appropriate values. Analog Output 2 controlled by writing to parameter 0136. Used for scaling

AO2 CONTENT MIN

MAXIMUM AO2 FILTER AO2

Filter time constant for AO2.

Fieldbus adapter

228

ACS550 Users Manual

PID Control setpoint source S dng ci t di y chn fieldbus nh ngun im t cho PID vng knh :
Drive parameter 4010 4110 4210
SET POINT SEL SET POINT SEL SET POINT SEL

Value 8 (COMM VALUE 1) 9 (COMM+AI1) 10 (COMM*AI1)

Setting im t l u vo tham chiu 2 (+/-/* AI1)

Protocol reference

(Set 1) (Set 2) (Ext/Trim)

Communication fault Khi s dng kim sot fieldbus , xc nh bin tn hot ng nu truyn thng ni tip b mt .
Drive parameter 3018
COMM FAULT FUNC

Value 0 (NOT SEL) 1 (FAULT) 2 (CONST SP7) 3 (LAST SPEED)

Description Thit lp cho bin tn phn ng thch hp.

3019

COMM FAULT TIME

Thit lp thi gian tr trc khi hot ng trn mt truyn thng b mt.

Feedback from the drive FBA


u vo n b iu khin (u ra bin tn) c ngha c xc nh trc ngha c sn bi phng thc. phn hi ny khng i hi cu hnh bin tn. bng sau y lit k cc mu ca d liu phn hi. Cho y danh sch, xem tt c danh sch tham s trong phn Complete parameter descriptions trn trang 98.
Drive parameter 0102 0103 0104 0105 0106 0107 0109 0301 0301 0118
SPEED OUTPUT FREQ CURRENT TORQUE POWER DC BUS VOLTAGE OUTPUT VOLTAGE FB CMD WORD FB CMD WORD DI

Protocol reference

1 bit 0 (STOP) 1 bit 2 (REV)

1-3 STATUS bit 0 (DI3)

Scaling t l gi tr tham s bin tn xem nhng phn sau, nh tng thch: Actual Value scaling trn trang 239 (ABB Drives profile technical data) Actual Value scaling trn trang241 (Generic profile technical data).

Fieldbus adapter

ACS550 Users Manual

229

Diagnostics FBA
Fault handling ACS550 cung cp thng tin cc li nh sau : mng hnh bng iu khin hin th mt m li v vn bn. xem chng Diagnostics trn trang 243 cho m t y . tham s 0401 LAST FAULT, 0412 PREVIOUS FAULT1 and 0413 PREVIOUS FAULT2 lu tr li gn y nht . cho truy cp fieldbus, bin tn bo li nh gi tr thp lc phn, c gn v m ha theo cc c im k thut DRIVECOM . xem bng di y. Khng phi tt c bin dng h tr yu cu m li s dng c im k thut ny. Cho thng tin h tr c im k thut ny, ti liu thng tin c xc nh qu trnh li theo yu cu thch hp .
Drive fault code 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19 20 21 22 23 24 25 26 OVERCURRENT DC OVERVOLT DEV OVERTEMP sHORT CIRC Reserved DC UNDERVOLT AI1 LOSS AI2 LOSS MOT OVERTEMP PANEL LOSS ID RUN FAIL MOTOR STALL EXT FAULT1 EXT FAULT2 EARTH FAULT Obsolete THERM FAIL OPEX LINK OPEX PWR CURR MEAS SUPPLY PHASE ENCODER ERR OVERSPEED Reserved DRIVE ID Fieldbus fault code (DRIVECOM specification) 2310h 3210h 4210h 2340h FF6Bh 3220h 8110h 8110h 4310h 5300h FF84h 7121h 9000h 9001h 2330h FF6Ah 5210h 7500h 5414h 2211h 3130h 7301h 7310h FF80h 5400h

Fieldbus adapter

230

ACS550 Users Manual

Drive fault code 27 28 29 30 31 32 33 34 35 36 37 38 101 102 103 104 105 201 202 203 204 205 206 207 1000 1001 1002 1003 1004 1005 1006 1007 1008 1009 1012 1013 1014 1016 CONFIG FILE SERIAL1 ERR EFB CON FILE FORCE TRIP EFB 1 EFB 2 EFB 3 MOTOR PHASE OUTP WIRING INCOMPATIBLE SW CB OVERTEMP USER LOAD CURVE SERF CORRUPT Reserved SERF MACRO Reserved Reserved DSP T1 OVERLOAD DSP T2 OVERLOAD DSP T3 OVERLOAD DSP STACK ERROR Reserved (obsolete) CB ID ERROR EFB LOAD ERR PAR HZRPM PAR PFC REF NEG Reserved (obsolete) PAR AI SCALE PAR AO SCALE PAR PCU2 PAR EXT RO PAR FIELDBUS MISSING PAR PFC MODE PAR PCU1 PAR PFC IO1 PAR PFC IO2 PAR PFC IO3 PAR USER LOAD C

Fieldbus fault code (DRIVECOM specification) 630Fh 7510h 6306h FF90h FF92h FF93h FF94h FF56h FF95h 630Fh 4110h FF6Bh FF55h FF55h FF55h FF55h FF55h 6100h 6100h 6100h 6100h 5000h 5000h 6100h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h 6320h

Fieldbus adapter

ACS550 Users Manual

231

Serial communication diagnostics Ngoi cc m li bin tn , FBA module c cc cng c m t. tham chiu hng dn s dng cung cp vi FBA module.

Fieldbus adapter

232

ACS550 Users Manual

ABB Drives profile technical data


Overview ABB Drives thng tin cung cp mt bin dng tiu chun c th c s dng trn nhiu giao thc , bao gm cc giao thc c sn trn FBA module. Phn ny m t ABB Drives thng tin thc hin cho FBA modules. Control Word Nh c m t trc trong phn Control interface trn trang 222, CONTROL WORD l phng tin chnh cho kim sot bin tn t h thng fieldbus . Bng sau y v trng thi sau ny trong phn nh ny m t ni dung CONTROL WORD cho thng tin ABB Drives .
ABB Drives profile (FBA) CONTROL WORD Bit 0 Name OFF1 CONTROL Value 1 0 Commanded state Comments

READY TO OPERATE Enter SN SNG HOT NG EMERGENCY OFF Bin tn dng theo dc ph hp vi dc hot ng gim tc (2203 hoc 2205) chui lnh bnh thng: nhp OFF1 ACTIVE tip tc READY TO SWITCH ON, tr khi cc kha lin ng khc (OFF2, OFF3)ang hot ng .

OFF2 CONTROL

1 0

OPERATING EMERGENCY OFF

Tip tc hot ng (OFF2 khng hot ng) Bin tn dng theo dc. chui lnh bnh thng: nhp OFF2 ACTIVE tip tc SWITCHON INHIBITED

OFF3 CONTROL

1 0

OPERATING EMERGENCY STOP

Tip tc hot ng (OFF3 khng hot ng) Bin tn dng trong thi gian quy nh bi tham s 2208. chui lnh bnh thng: nhp OFF3 ACTIVE tip tc SWITCH ON INHIBITED Cnh bo ! hy chc chn ng c v thit b iu khin c th dng li bng cch s dng ch ny.

INHIBIT OPERATION

OPERATION ENABLED

Nhp OPERATION ENABLED (ch tn hiu cho php chy phi c kch hot. xem 1601. nu 1601 l t n COMM, bit ny cng kch hot tn hiu cho php chy .) c ch hot ng. nhp OPERATION INHIBITED Nhp RAMP FUNCTION GENERATOR: ACCELERATION ENABLED Dc chc nng lc u ra my pht n 0. bin tn dng theo dc (dng in v gii hn in p DC trong lc tc dng).

0 4 RAMP_OUT_ ZERO 1 0

OPERATION INHIBITED NORMAL OPERATION RFG OUT ZERO

Fieldbus adapter

ACS550 Users Manual

233

ABB Drives profile (FBA) CONTROL WORD Bit 5 Name RAMP_HOLD Value 1 Commanded state RFG OUT ENABLED Comments Cho php dc chc nng . Nhp RAMP FUNCTION GENERATOR: ACCELERATOR ENABLED 0 6 RAMP_IN_ ZERO 1 0 0=>1 RFG OUT HOLD Dng dc (dc chc nng pht in u ra held)

RFG INPUT ENABLED hot ng bnh thng. nhp OPERATING RFG INPUT ZERO RESET dc lc chc nng my pht u vo n 0. Li reset nu li hot ng vn tn ti (nhp SWITCH-ON INHIBITED). Hiu qu nu 1604 = COMM. Tip tc hot ng bnh thng

RESET

0 89 10 Unused REMOTE_CMD 1 0

OPERATING

Kim sot Fieldbus c kch hot CW = 0/ hoc Ref =/ 0: Retain last CW v Ref. CW = 0 v Ref = 0: kim sot Fieldbus cho php . tham chiu v dc tng tc / gim tc c kha .

11

EXT CTRL LOC

1 0

EXT2 SELECT EXT1 SELECT

Chn v tr kim sot bn ngoi 2 (EXT2). hiu qu nu 1102 = COMM. Chn v tr kim sot bn ngoi 1 (EXT1). hiu qu nu 1102 = COMM.

1215

Unused

Status Word Nh c m t trc trong phn Control interface trn trang 222, ni dung ca STATUS WORD l tnh trng thng tin , gi bi bin tn n trm ch. Bng sau y v trng thi sau ny trong phn nh ny m t trng thi ni dung ca word .
ABB Drives profile (FBA) STATUS WORD Bit 0 RDY_ON Name Value 1 0 1 RDY_RUN 1 0 2 RDY_REF 1 0 3 TRIPPED 01 0 Description (Correspond to states/boxes in the state diagram) READY TO SWITCH ON NOT READY TO SWITCH ON READY TO OPERATE OFF1 ACTIVE OPERATION ENABLED OPERATION INHIBITED FAULT No fault

Fieldbus adapter

234

ACS550 Users Manual

ABB Drives profile (FBA) STATUS WORD Bit 4 Name OFF_2_STA Value 1 0 5 OFF_3_STA 1 0 6 SWC_ON_INHIB 1 0 7 ALARM 1 0 8 AT_SETPOINT 1 0 9 REMOTE 1 0 10 ABOVE_LIMIT 1 Description (Correspond to states/boxes in the state diagram) OFF2 inactive OFF2 ACTIVE OFF3 inactive OFF3 ACTIVE SWITCH-ON INHIBIT ACTIVE SWITCH-ON INHIBIT NOT ACTIVE Bo ng (xem phn Alarm listing trn trang 250 bit chi tit v h thng bo ng . khng bo ng OPERATING. gi tr thc t bng (trong gii hn dung sai) gi tr tham chiu . gi tr thc t l ngoi gii hn dung sai (khng bng gi tr tham chiu ). Kim sot v tr bin tn: REMOTE (EXT1 hoc EXT2) Kim sot v tr bin tn: LOCAL Tham s gim st l gi tr > cao hn gii hn gim st. Bit vn cn 1 n khi tham s gim st l gi tr < thp hn gii hn gim st . xem nhm 32: SUPERVISION. 0 Tham s gim st l gi tr < thp hn gii hn gim st. Bit vn cn 0 n khi tham s gim st l gi tr > cao hn gii hn gim st. xem nhm 32: SUPERVISION. 11 EXT CTRL LOC 1 0 12 EXT RUN ENABLE 1 0 13 15 cha s dng Kim sot v tr bin tn 2 ( EXT2) c chn . Kim sot v tr bin tn 1 (EXT1) c chn . Nhn c tn hiu cho php chy bn ngoi Khng nhn c tn hiu cho php chy bn ngoi

Fieldbus adapter

ACS550 Users Manual

235

S trng thi di y m t chc nng khi ng dng ca CONTROL WORD (CW) v STATUS WORD (SW) bits.
T bt k trng thi Emergency Stop OFF3 (CW Bit2=0) (SW Bit5=0) OFF3 ACTIVE OFF2 ACTIVE T bt k trng thi Emergency Off OFF2 (CW Bit1=0) (SW Bit4=0) T bt k trng thi Fault FAULT (SW Bit3=1) (CW Bit7=1)

n(f)=0 / I=0 From any state OFF1 (CW Bit0=0) (SW Bit1=0) n(f)=0 / I=0 OFF1 ACTIVE MAINS OFF Power ON

SWITCH-ON INHIBITED

(SW Bit6=1)

(CW Bit0=0)

ABCD

NOT READY TO SWITCH ON

(SW Bit0=0)

(CW Bit3=0) (SW Bit2=0) OPERATION INHIBITED

(CW xxxx x1xx xxxx x110) READY TO SWITCH ON (SW Bit0=1)

OPERATION INHIBITED

(CW= xxxx x1xx xxxx x111) BCD

READY TO OPERATE

(SW Bit1=1)

(CW Bit4=0)

(CW Bit3=1 and SW Bit12=1) OPERATION ENABLED A (CW=xxxx x1xx xxx1 1111) RFG OUTPUT ENABLED B (CW=xxxx x1xx xx11 1111)

CD

(SW Bit2=1)

(CW Bit5=0)

D (CW Bit6=0) KEY Trng thi Thay i trng thi CW = CONTROL WORD SW = STATUS WORD RFG = dc chc nng my pht I = Param. 0104 CURRENT f = Param. 0103 OUTPUT FREQ n = tc D C

RFG: ACCELERATOR ENABLED (CW=xxxx x1xx x111 1111) OPERATING (SW Bit8=1)

Fieldbus adapter

236

ACS550 Users Manual

Reference Nh c m t trc trong phn Control interface trn trang 222, REFERENCE word l mt tc hoc tham chiu tn s . Reference scaling Bng di y m t t l REFERENCE cho thng tin ABB Drives .
ABB Drives Profile (FBA) Reference REF1 Range -32767 +32767 Reference type Speed or frequency Scaling -20000 = -(par. 1105) 0=0 +20000 = (par. 1105) (20000 corresponds to 100%) REF2 -32767 +32767 Speed or frequency -10000 = -(par. 1108) 0=0 +10000 = (par. 1108) (10000 corresponds to 100%) Torque -10000 = -(par. 1108) 0=0 +10000 = (par. 1108) (10000 corresponds to 100%) PID Reference -10000 = -(par. 1108) 0=0 +10000 = (par. 1108) (10000 corresponds to 100%) Tham chiu cui cng gii hn bi 4012/4013 (PID set1) hoc 4112/4113 (PID set2). Remarks Tham chiu cui cng gii hn bi 1104/1105. tc thc t ng c gii hn bi 2001/2002 (tc ) hoc 2007/2008 (tn s ). Tham chiu cui cng gii hn bi 1107/1108. tc thc t ng c gii hn bi 2001/2002 (tc ) hoc 2007/2008 (tn s ). Tham chiu cui cng gii hn bi 2015/2017 (torque1) hoc 2016/2018 (torque2).

Ch : thit lp ca tham s 1104 REF1 MIN v 1107 REF2 MIN khng c tc dng trn t l ca tham chiu . Khi tham s 1103 REF1 SELECT hoc 1106 REF2 SELECT l t n COMM+AI1 hoc COMM*AI1, t l tham chiu l nh sau y :
ABB Drives profile (FBA) Reference REF1 Value setting COMM+AI1 AI reference scaling COMM(%) + (AI (%) - 0.5 REF1 MAX (%)) Fieldbus reference correction coefficient (100 + 0.5 (Par. 1105)%

100% AI1 input signal 0% 50% 100%

(100 - 0.5 (par. 1105))%

Fieldbus adapter

ACS550 Users Manual

237

ABB Drives profile (FBA) Reference REF1 Value setting


COMM*AI1 COMM

AI reference scaling (%) (AI (%) / 0.5 REF1 MAX (%)) Fieldbus reference correction coefficient 200%

100% AI1 input signal (100 - 0.5 (par. 1105))% 0% REF2


COMM+AI1 COMM

50%

100%

(%) + (AI (%) - 0.5 REF2 MAX (%)) Fieldbus reference correction coefficient

(100 + 0.5 (Par. 1108)%

100% AI1 input signal (100 - 0.5 (par. 1108)% 0% REF2


COMM*AI1 COMM

50%

100%

(%) (AI (%) / 0.5 REF2 MAX (%)) Fieldbus reference correction coefficient 200%

100% AI1 input signal 0% 50% 100%

0%

Fieldbus adapter

238

ACS550 Users Manual

Reference handling S dng nhm 10: START/STOP/DIR tham s cu hnh cho kim sot hng quay cho mi v tr kim sot (EXT1 v EXT2). Cc s sau y minh ha lm th no nhm thng s 10 v biu tng ca tham chiu fieldbus tng tc sn xut gi tr REFERENCE (REF1 v REF2). Ch , tham chiu fieldbus l lng cc, ngha l n c th dng hoc m .
ABB Drives profile Parameter 1003 DIRECTION Value setting 1 (FORWARD) Max. ref AI reference scaling Resultant ref.

Fieldbus reference

-163% -100%

100% 163%

-(Max. ref.) 1003 DIRECTION 2 (REVERSE) Max. ref Resultant ref. Fieldbus -163% -100% reference 100% 163%

-(Max. ref.) 1003 DIRECTION 3 (REQUEST) Max. ref Resultant ref.

Fieldbus reference

-163% -100% 100% 163%

-(Max. ref.)

Fieldbus adapter

ACS550 Users Manual

239

Actual Value Nh c m t trc trong phn Control interface trn trang 222, gi tr thc t l cc t cha cc gi tr ca bin tn. Actual Value scaling T l cc s nguyn gi cho fieldbus nh gi tr thc t ph thuc trn phn gii ca chn tham s bin tn. ngoi tr nh nu cho ACT 1 v ACT2 sau y, t l s nguyn thng tin phn hi bng cch s dng danh sch phn gii cho tham s trong phn Complete parameter list trn trang 85. v d :
Feedback integer 1 10 Parameter resolution 0.1 mA 0.1% Scaled Value 1 0.1 mA = 0.1 mA 10 0.1% = 1%

D liu cc t 5 v 6 l t l di y :
ABB Drives profile Contents ACT1 ACT2
ACTUAL SPEED TORQUE

Scaling -20000 +20000 = -(par. 1105) +(par. 1105) -10000 +10000 = -100% +100%

Virtual addresses of the drive control a ch o ca vic kim sot bin tn c phn b nh sau :
1 2 3 4 5 6 Control Word Reference 1 (REF1) Reference 2 (REF2) Status Word Actual Value 1 (ACT1) Actual Value 2 (ACT2)

Fieldbus adapter

240

ACS550 Users Manual

Generic profile technical data


Overview Cc thng tin chung chung nhm thc hin y tiu chun cng nghip thng tin bin tn cho mi giao thc (e.g. PROFIdrive for PROFIBUS, AC/DC Drive for DeviceNet). Control Word Nh c m t trc trong phn Control interface trn trang 222, CONTROL WORD phng tin chnh kim sot bin tn t mt h thng fieldbus. Cho c th ni dung CONTROL WORD , xem hng dn s dng cng vi FBA module. Status Word Nh c m t trc trong phn Control interface trn trang 222, ni dung ca STATUS WORD l thng tin trng thi, gi bi bin tn n trm ch. Cho c th ni dung STATUS WORD , xem hng dn s dng cng vi FBA module. Reference Nh c m t trc trong phn Control interface trn trang 222, REFERENCE t l tc hoc tn s tham chiu . Ch : REF2 khng c h tr bi thng tin Generic Drive. Reference scaling
REFERENCE t

l l loi fieldbus c th tuy nhin , vo bin tn ngha ca 100% REFERENCE gi tr l c nh nh m t trong bng di y.cho m t chi tit trn phm vi v t l ca REFERENCE, xem hng dn s dng cng vi FBA module .

Generic profile Reference REF Range Fieldbus specific Reference type Speed Scaling -100% = -(par. 9908) 0=0 +100 = (par. 9908) -100% = -(par. 9907) 0=0 +100 = (par. 9907) Remarks Tham chiu cui cng gii hn bi 1104/1105. Tc thc t ng c gii hn bi 2001/ 2002 (tc ). Tham chiu cui cng gii hn bi 1104/1105. Tc thc t ng c gii hn bi 2007/ 2008 (tn s).

Frequency

Actual Values Nh c m t trc trong phn Control interface trn trang 222, gi tr thc t l t cha trong gi tr bin tn .

Fieldbus adapter

ACS550 Users Manual

241

Actual Value scaling Gi tr thc t, t l s nguyn phn hi bng cch s dng phn gii ca tham s. (xem phn Complete parameter list trn trang 85 cho phn gii tham s.) v d :
Feedback integer 1 10 Parameter resolution 0.1 mA 0.1% (Feedback integer) (Parameter resolution) = Scaled Value 1 0.1 mA = 0.1 mA 10 0.1% = 1%

Trng hp cc thng s nm trong phn trm, Complete parameter list chn quy nh c th ci g tng ng vi 100%. Trong trng hp ny, chuyn i t phn trm n n v k thut , nhn vi gi tr ca tham s mc nh 100% v chia bi 100%. V d :
Feedback integer 10 100
1 2

Parameter resolution 0.1% 0.1%

Value of the parameter that defines 100% 1500 rpm1 500 Hz2

(Feedback integer) (Parameter resolution) (Value of 100% ref.) / 100% = Scaled Value 10 0.1% 1500 RPM / 100% = 15 rpm 100 0.1% 500 Hz / 100% = 50 Hz

Gi s, cho sake ca v d ny, rng gi tr thc t s dng tham s 9908 MOT NOM SPEED nh 100% tham chiu v rng 9908 = 1500 rpm. Gi s, cho sake ca v d ny, rng gi tr thc t s dng tham s 9907 MOT NOM FREQ nh 100% tham chiu v rng 9907 = 500 Hz.

Actual Value mapping xem hng dn s dng cng vi FBA module.

Fieldbus adapter

242

ACS550 Users Manual

Fieldbus adapter

ACS550 Users Manual

243

Diagnostics

Cnh bo! Khng tm cch o lng, thay th cc b phn sn xut dnh v khc m khng c m t trong s tay ny . Lm nh vy s mt hiu lc bo hnh, c th gy nguy him cho hot ng chnh xc v tng thi gian cht v chi ph .

Cnh bo ! tt c cc ci t in v cng vic bo tr c m t trong chng ny ch nn c thc hin bi nhn vin phc v c trnh . Cc hng dn an ton trong chng Safety trn trang 5 phi c theo sau .

Diagnostic displays
Bin tn pht hin tnh hung li v bo cho h bng cch s dng : cc LED xanh v trn sn ca bin tn . tnh trng LED trn bng iu khin (nu mt Assistant Control Panel c gn vo bin tn) mng hnh bng iu khin (nu mt bng iu khin c gn vo bin tn) Fault Word v Alarm Word tham s bits (tham s 0305 n 0309). xem nhm 03: FB ACTUAL SIGNALS trn trang 104 cho nh ngha bit. Hnh thc hin th ph thuc vo mc nghim trng ca li. bn c th xc nh mc nghim trng ca nhiu li bi ch o bin tn n : b qua tnh hnh sai lch . bo co tnh hnh nh bo ng . bo co tnh hnh nh mt li . Red Faults Bin tn pht tn hiu rng n pht hin mt li nghim trng, hoc li, bi : cho php LED trn bin tn (LED sng n nh hoc nhp nhy) LED trng thi hin th n nh trn bng iu khin (nu gn vo bin tn) thit lp mt bit thch hp trong tham s Fault Word (0305 n 0307) u tin kim sot bng iu khin vi mng hnh hin th ca m li trong ch Fault ( con s bn phi ) dng ng c (nu n ang chy). M li trn bng iu khin hin th l tm thi . Nhn bt k phm sau y loi b tin nhn li : MENU, ENTER, UP, hoc phm DOWN.
LOC

LOC

FAULT

FAULT 8
AI1 LOSS 00:00

F0008

FWD

Diagnostics

244

ACS550 Users Manual

Tin nhn ny li xut hin sau vi giy nu bng iu khin khng c tip xc v li vn cn hot ng. Flashing green Alarms i vi li t nghim trng, c gi l bo ng, mng hnh hin th m t l t vn . i vi nhng tnh hung ny, bin tn ch n gin bo co rng n pht hin ci g bt thng. trong tnh hung ny, bin tn : nhp nhy LED mu xanh trn bin tn (khng p dng cho cc bo ng pht sinh t li kim sot hot ng ca bng iu khin) nhp nhy LED mu xanh trn bin tn (c nh trn bin tn) thit lp mt bit ph hp trong tham s Alarm Word (0308 hoc 0309). xem nhm 03: FB ACTUAL SIGNALS trn trang 104 nh ngha cc bit ghi bng iu khin hin th vi hin th ca mt m bo ng/hoc tn trong ch li (con s bn phi). Tin nhn bo ng bin mt trong mng hnh hin th sau vi giy. Tin nhn tr v theo nh k min l tn ti tnh trng bo ng .
LOC ALARM

ALARM 2008
PANEL LOSS 00:00
LOC

A2008

FWD

Correcting faults
Cc hnh ng khc phc c ngh cho li l : s dng cc bng trong phn Fault listing di y tm v a ch gii quyt nguyn nhn gc ca vn . Reset bin tn . xem phn Fault resetting trn trang 249. Fault listing Bng sau y lit k cc li bi m s v tng m t . Tn li dng di c hin th ch Fault ca Assistant Control Panel khi c li xy ra . tn li hin th (ch cho Assistant Control Panel ) trong ch Fault Logger (xem trang 55) v tn li cho tham s 0401 LAST FAULT c th ngn hn .
Fault code 1 Fault name in panel Description and recommended corrective action

OVERCURRENT Ng ra dng in l qu. kim tra v ng : ng c qu ti . thi gian tng tc khng (tham s 2202 ACCELER TIME 1 v 2205 ACCELER TIME 2). li ng c, cp ng c hc kt ni .

Diagnostics

ACS550 Users Manual

245

Fault code 2

Fault name in panel DC OVERVOLT

Description and recommended corrective action Qu in p mch trung gian DC. Kim tra v ng: dng hoc qu p nht thi trong vic cung cp nng lng u vo. khng thi gian gim tc (tham s 2203 DECELER TIME 1 v 2206 DECELER TIME 2). thng in cha kch thc (nu c). xc nhn rng b iu khin qu p l ON (s dng tham s 2005).

DEV OVERTEMP Tn nhit bin tn qu nng. Nhit ti hoc cao hn gii hn . R1R4 & R7/R8: 115 C (239 F) R5/R6: 125 C (257 F) Kim tra v hiu chnh : qut hng . c vt cn trong dng chy khng kh . bu hoc bt ph trn tn nhit . qu nhit mi trng xung quanh . qu ti ng c .

SHORT CIRC

Li dng in . Kim tra v ng: ngn mch trong cp ng c (s) hoc ng c. cung cp b nhiu.

5 6

RESERVED

Khng s dng.

DC UNDERVOLT in p mch trung gian DC l cha . Kim tra v ng: thiu phase trong ngun in cung cp. n cu ch. thp p trn li in .

AI1 LOSS

u vo tng t 1 b mt. Gi tr u vo tng t l thp hn AI1 FAULT LIMIT (3021).kim tra v hiu chnh: ngun v kt ni u vo tng t . ci t cc thng s cho AI1 FAULT LIMIT (3021) v 3001 AI<MIN FUNCTION.

AI2 LOSS

u vo tng t 2 b mt. Gi tr u vo tng t l thp hn AI2 FAULT LIMIT (3022).kim tra v hiu chnh: ngun v kt ni u vo tng t. ci t cc thng s cho AI2 FAULT LIMIT (3022) v 3001 AI<MIN FUNCTION.

MOT OVERTEMP

ng c qu nng , hoc da trn c tnh khc ca bin tn hoc trn phn hi nhit . kim tra qu ti ng c . iu chnh cc tham s cho d ton (30053009). kim tra cm bin nhit v nhm 35: MOTOR TEMP MEAS Tham s .

10

PANEL LOSS

Truyn thng bng iu khin l mt hoc l: bin tn trong ch kim sot cc b (kim sot bng iu khin hin th LOC), hoc bin tn trong ch kim sot t xa (REM) v tham s chp nhn khi ng dng, hng hoc tham chiu t bng iu khin . chnh xc kim tra : ng truyn thng v kt ni. tham s 3002 PANEL COMM ERR. tham s trong nhm 10: START/STOP/DIR v Group 11: REFERENCE SELECT (nu hot ng bin tn l REM).

Diagnostics

246

ACS550 Users Manual

Fault code 11

Fault name in panel ID RUN FAIL

Description and recommended corrective action ID Run ng c hon thnh khng thnh cng . kim tra v ng: kt ni ng c . tham s ng c 99059909.

12

MOTOR STALL

ng c hoc qu trnh ngng chy. ng c ang hot ng trong khu vc ngng. chy . kim tra v hiu chnh: qu ti . ng c thiu cng sut . tham s 30103012.

13 14 15 16

RESERVED EXT FAULT1 EXT FAULT2 EARTH FAULT

Khng s dng . u vo s c xc nh bo li u tin bn ngoi hot ng. xem tham s 3003 EXTERNAL FAULT 1. u vo s c xc nh bo li bn ngoi th hai hot ng. xem tham s 3004 EXTERNAL FAULT 2. Li ni t c th c pht hin trong ng c hoc cp ng c . Bin tn gim st cho li ni t trong khi bin tn ang chy v trong khi bin tn khng chy . Pht hin ny l nhy cm hn khi bin tn khng chy v c th gy ra dng sai . c th hiu chnh : kim tra/hiu chnh li trong h thng dy in u vo . xc nh rng cp ng c khng vt qu di ti a quy nh . ni t tam gic u vo ngun cung cp v cp ng c vi in dung cao c th dn n bo li sai trong qu trnh th nghim khng chy . c trng v hiu ha n gim st li khi bin tn khng chy, s dng tham s 3023 WIRING FAULT. phn ng v hiu ha cc gim st li ni t, s dng tham s 3017 EARTH FAULT.

17 18 19

OBSOLETE THERM FAIL OPEX LINK

Khng s dng. Li bn trong. Cc nhit in tr o nhit bn trong ca bin tn l m hoc thiu . lin lc vi i din ABB ca bn . Li bn trong. Mt vn lin quan n truyn thng c pht hin trn dy lin kt gia kim sot v board OINT. lin lc vi i din ABB ca bn . Li bn trong. iu kin in p thp c pht hin trn OINT ngun cung cp . lin lc vi i din ABB ca bn. Li bn trong. Dng in o c ra khi phm vi. lin lc vi i din ABB ca bn . gn sng in p trong lin kt DC l qu cao. Kim tra v ng: thiu phase ngun in . n cu ch .

20 21 22

OPEX PWR CURR MEAS SUPPLY PHASE

23

ENCODER ERR

Bin tn khng pht hin tn hiu m ha ph hp . Kim tra v ng: Encoder hin din v kt ni ph hp (ngc dy, kt ni lng hoc ngn mch ). in p mc logic l ngoi phm vi quy nh . vn hnh v ng kt ni Pulse Encoder giao din Module, OTAC-01. sai gi tr nhp trong tham s 5001 PULSE NR. Sai gi tr s ch c xc nh nu nu li l c tnh lowng hn 4 ln so vi dnh gi ca ng c . Encoder khng c s dng, nhng tham s 5002 ENCODER ENABLE = 1 (ENABLE).

Diagnostics

ACS550 Users Manual

247

Fault code 24

Fault name in panel OVERSPEED

Description and recommended corrective action Tc ng c ln hn 120% ln hn (trong ln) of 2001 MINIMUM SPEED hoc 2002 MAXIMUM SPEED. Kim tra v ng: ci t tham s cho 2001 v 2002. y ca braking torque ng c . kh nng ng dng ca kim sot momen xon. Brake chopper l in tr .

25 26 27 28

RESERVED DRIVE ID CONFIG FILE SERIAL1 ERR

Khng s dng. Li bn trong. Cu hnh Block Drive ID khng hp l. lin h vi i din ABB ca bn . Tp tin cu hnh bn trong b li . lin h vi i din ABB ca bn . truyn thng Fieldbus qu gii hn. Kim tra v ng: li thit lp (3018 COMM FAULT FUNC v 3019 COMM FAULT TIME). ci t truyn thnd (nhm 51: EXT COMM MODULE hoc Group 53: EFB PROTOCOL tng thch ). kt ni xu v/hoc ting n trn ng dn.

29 30 31 32 33 34

EFB CON FILE FORCE TRIP EFB 1 EFB 2 EFB 3 MOTOR PHASE

Li trong tp tin cu hnh t vo fieldbus. Li ngt bt but bi fieldbus. Xem hng dn s dng fieldbus . M li dnh ring cho fieldbus (EFB)giao thc ng dng . C ngha l giao thc ph thuc .

Li trong mch ng c. Mt trong nhng pha ca ng c b mt. kim tra v iu chnh : li ng c . li cp ng c. li relay nhit (nu c s dng ). li bn trong .

35

OUTP WIRING

C th pht hin li h thng dy in. khi bin tn khng chy n gim st mt kt ni khng ph hp gia u vo in nng bin tn v u ra bin tn. Kim tra v hiu chnh: ng u vo h thng dy in ng dn in p l khng kt ni vi u ra bin tn. li c th thit lp sai nu u vo ngun in l h thng ni t tam gic v cp ng c c in dung rt ln. li ny c th c v hiu ha bng cch s dng tham s 3023 WIRING FAULT.

36

INCOMPATIBL E XW

Bin tn c th khng s dng phn mm. li bn trong . cc phn mm c ti khng tng thch vi bin tn . gi i din h tr.

37

CB OVERTEMP

board kim sot bin tn l qu nng. Gii hn ngt li l 88 C. kim tra v hiu chnh : qu mc nhit mi trng xung quanh . qut hng . vt cn trong dng chy khng kh . Khng cho bin tn vi mt OMIO kim sot board.

38

USER LOAD CURVE

iu kin c xc nh bi tham s 3701 USER LOAD C MODE c hp l di hn thi gian quy nh bi 3703 USER LOAD C TIME.

Diagnostics

248

ACS550 Users Manual

Fault code 101 199 201 299

Fault name in panel

Description and recommended corrective action

SYSTEM ERROR Li bn trong bin tn. lin h vi i din ABB ca bn v bo s ca li . SYSTEM ERROR Li h thng . lin h vi i din ABB ca bn v bo s ca li .

UNKNOWN DRIVE TYPE: ACS550 SUPPORTED DRIVES: X

Sai loi bng , i.e. bng iu khin h tr bin tn X nhng khng phi l ACS550, c kt ni vi ACS550.

Li ch ra nhng mu thun trong cc ci t tham s c lit k di y .


Fault code 1000 Fault name in panel PAR HZRPM Description and recommended corrective action Cc gi tr tham s l khng ph hp . kim tra bt k cc tham s sau y : 2001 MINIMUM SPEED > 2002 MAXIMUM SPEED. 2007 MINIMUM FREQ > 2008 MAXIMUM FREQ. 2001 MINIMUM SPEED / 9908 MOTOR NOM SPEED l trng hp ngoi phm vi (> 50). 2002 MAXIMUM SPEED / 9908 MOTOR NOM SPEED l trng hp ngoi phm vi (> 50). 2007 MINIMUM FREQ / 9907 MOTOR NOM FREQ l trng hp ngoi phm vi (> 50). 2008 MAXIMUM FREQ / 9907 MOTOR NOM FREQ l trng hp ngoi phm vi (> 50). 1001 PAR PFC REF NEG RESERVED PAR AI SCALE Cc gi tr tham s l khng ph hp . kim tra cc iu sau y: 2007 MINIMUM FREQ l m, khi 8123 PFC ENABLE l hot ng . Khng s dng . Cc gi tr tham s l khng ph hp . kim tra bt c tham s sau y: 1301 MINIMUM AI1 > 1302 MAXIMUM AI1. 1304 MINIMUM AI2 > 1305 MAXIMUM AI2. 1004 PAR AO SCALE Cc gi tr tham s l khng ph hp . kim tra bt c tham s sau y: 1504 MINIMUM AO1 > 1505 MAXIMUM AO1. 1510 MINIMUM AO2 > 1511 MAXIMUM AO2. 1005 PAR PCU 2 Cc gi tr tham s cho kim sot cng sut l khng ph hp : danh nh ng c khng ng kVA hoc cng sut anh nh ng c. Kim tra cc iu sau y : 1.1 < (9906 MOTOR NOM CURR 9905 MOTOR NOM VOLT 1.73 / PN) < 3.0 Trong : PN = 1000 9909 MOTOR NOM POWER (nu n v l kW) hoc PN = 746 9909 MOTOR NOM POWER (nu n v l hp, e.g. in US) 1006 PAR EXT RO Cc gi tr tham s l khng ph hp . kim tra cc iu sau y: module relay m rng l khng c kt ni . 14101412 RELAY OUTPUTS 46 c gi tr khc khng. 1007 PAR FIELDBUS MISSING Cc gi tr tham s l khng ph hp . kim tra cc iu sau y: mt tham s l thit lp cho kim sot fieldbus (e.g. 1001 EXT1 COMMANDS = 10 (COMM)), nhng 9802 COMM PROT SEL = 0. Cc gi tr tham s l khng ph hp 9904 MOTOR CTRL MODE phi c = 3 (SCALAR:FREQ), khi 8123 PFC ENABLE c kch hot .

1002 1003

1008

PAR PFC MODE

Diagnostics

ACS550 Users Manual

249

Fault code 1009

Fault name in panel PAR PCU 3

Description and recommended corrective action Cc gi tr tham s cho kim sot cng sut l khng ph hp : khng ng tn s hoc tc danh nh. Kim tra c hai sau y : 1 < (60 9907 MOTOR NOM FREQ / 9908 MOTOR NOM SPEED < 16 0.8 < 9908 MOTOR NOM SPEED / (120 9907 MOTOR NOM FREQ / Motor Poles) < 0.992

1010/ 1011 1012

RESERVED PAR PFC IO 1

Khng s dng. Cu hnh IO l khng ph hp khng relay c tham s ha n PFC. Hoc, hoc mt mu thun hin c gia nhm 14: RELAY OUTPUTS, tham s 8117 NR OF AUX MOT v tham s 8118 AUTOCHNG INTERV. Cu hnh IO l khng ph hp s lng thc t ca ng c PFC (tham s 8127, MOTORS) khng ph hp vi cc ng c PFC trong nhm 14: RELAY OUTPUTS v tham s 8118 AUTOCHNG INTERV. Cu hnh IO l khng ph hp bin tn l khng th phn b cc u vo s (kha lin ng ) hoc mi ng c PFC (tham s 8120 INTERLOCKS v 8127 MOTORS). Khng s dng . Cc gi tr tham s s dng ng cong ti khng ph hp . kim tra xem cc iu kin sau y : 3704 LOAD FREQ 1 < 3707 LOAD FREQ 2 < 3710 LOAD FREQ 3 < 3713 LOAD FREQ 4 < 3716 LOAD FREQ 5. 3705 LOAD TORQ LOW 1 < 3706 LOAD TORQ HIGH 1. 3708 LOAD TORQ LOW 2 < 3709 LOAD TORQ HIGH 2. 3711 LOAD TORQ LOW 3 < 3712 LOAD TORQ HIGH 3. 3714 LOAD TORQ LOW 4 < 3715 LOAD TORQ HIGH 4. 3717 LOAD TORQ LOW 5 < 3718 LOAD TORQ HIGH 5.

1013

PAR PFC IO 2

1014

PAR PFC IO 3

1015 1016

RESERVED PAR USER LOAD C

Fault resetting ACS550 c th c cu hnh t ng reset nhng li no . tham chiu n tham s nhm 31: AUTOMATIC RESET. Cnh bo ! nu mt ngun tn hiu ngoi cho lnh khi ng c chn v n ang kch hot, ACS550 c th khi ng ngay sau khi reset li . Flashing red LED reset bin tn cho li c ch th bi LED nhp nhy : tt ngun khong 5 pht . Red LED reset bin tn cho li c ch th bi LED mu (sng, khng nhp nhy), ng vn v lm mt trong nhng iu sau y : nhn RESET t bng iu khin . tt ngun khong 5 pht. Ty thuc vo gi tr ca 1604 FAULT RESET SEL, sau cng c th c s dng reset bin tn :

Diagnostics

250

ACS550 Users Manual

u vo s truyn thng ni tip . Khi li sa cha, ng c c th c khi ng . History Cho tham chiu , ba m li cui cng c lu vo trong cc tham s 0401, 0412, 0413. i vi cc li gn y nht (xc nh bi tham s 0401), bin tn lu d liu b sung (trong cc tham s 04020411) h tr khc phc s c. cho v d, tham s 0404 lu tc ng c ti thi im ca li . Assistant Control Panel cung cp thm thng tin v lch s li . Xem phn Fault Logger mode trn trang 55 bit thm thng tin . xa lch s li ( tt c ca cc tham s nhm 04: FAULT HISTORY): 1. s dng bng iu khin trong ch tham s , chn tham s 0401. 2. nhn EDIT (hoc ENTER trn Basic Control Panel). 3. nhn UP v DOWN ng thi. 4. nhn SAVE.

Correcting alarms
Cc hnh ng khc phc c nghi cho bo ng l : xc nh nu bo ng i hi bt k hnh ng khc phc (hot ng l khng phi lun lun yu cu ). s dng cc bng trong phn Alarm listing di y tm v gi quyt nguyn nhn gc r ca vn . Alarm listing Bng sau y lit k cc bo ng bi m s v mi m t .
Alarm code 2001 Display OVERCURRENT Description B iu khin gii hn dng in ang hot ng . kim tra v ng : qu ti ng c . thi gian tng tc khng (tham s 2202 ACCELER TIME 1 v 2205 ACCELER TIME 2). ng c b li, cp ng c hoc kt ni. 2002 OVERVOLTAGE B iu khin qu in p hot ng. kim tra v ng : tnh trng hoc nht thi qu p trong u vo ngun cung cp. khng thi gian gim tc (tham s 2203 DECELER TIME 1 v 2206 DECELER TIME 2). 2003 UNDERVOLTAGE B iu khin thp p hot ng. kim tra v ng : thp p ngun in .

Diagnostics

ACS550 Users Manual

251

Alarm code 2004

Display DIR LOCK

Description Thay i hng th nghim l khng c cho php . hoc l : khng c gn thay i hng quay ng c, hoc thay i tham s 1003 DIRECTION cho php thay i hng (nu hot ng ngc li l an ton ).

2005

IO COMM

Truyn thng Fieldbus qu thi gian. Kim tra v ng : li thit lp (3018 COMM FAULT FUNC v 3019 COMM FAULT TIME). ci t truyn thng (nhm 51: EXT COMM MODULE hoc nhm 53: EFB PROTOCOL l ph hp ). kt ni ngho nng v/ting n trn ng truyn .

2006

AI1 LOSS

u vo tng t 1 l mt, hoc gi tr nh hn thit lp nh nht . kim tra : ngun u vo v cc kt ni . tham s m ci t nh nht (3021). tham s m ci t bo ng/li hot ng (3001),

2007

AI2 LOSS

u vo tng t 2 l mt, hoc gi tr nh hn thit lp nh nht. kim tra : ngun u vo v cc kt ni. tham s m ci t nh nht (3022). tham s m ci t bo ng/li hot ng (3001).

2008

PANEL LOSS

Truyn thng bng iu khin b mt v hoc l: bin tn trong ch kim sot cc b (bng iu khin hin th l LOC), hoc bin tn trong ch kim sot t xa (REM) v cc tham s chp nhn khi ng/dng, hng hoc tham chiu t bng iu khin . n kim tra ng : ng dn truyn thng v kt ni . tham s 3002 PANEL COMM ERR. tham s trong nhm 10: START/STOP/DIR v nhm 11: REFERENCE SELECT (nu hot ng bin tn l REM).

2009

DEVICE OVERTEMP

Tng nhit bin tn nng . bo ng ny cnh bo rng li DEVICE OVERTEMP c th gn n . R1R4 & R7/R8: 100 C (212 F) R5/R6: 110 C (230 F) Kim tra v ng : qut hng . c vt cn trong dng chy khng kh . bu hoc bt ph trn tn nhit. qu nhit mi trng xung quanh . qu ti ng c.

2010

MOTOR TEMP

ng c nng, da trn bin tn c tnh hoc trn nhit phn hi . bo ng ny cnh bo rng mt MOT OVERTEMP li ngt c th gn n. kim tra : kim tra qu ti ng c . iu chnh cc tham s c s dng cho d ton (30053009). kim tra cm bin nhit v nhm 35: MOTOR TEMP MEAS.

2011 2012

RESERVED MOTOR STALL

Khng s dng. ng c hot ng trong khu vc ngng chy. bo ng ny cnh bo rng MOTOR STALL li ngt c th gn n .

Diagnostics

252

ACS550 Users Manual

Alarm code 2013 (Note 1)

Display AUTORESET

Description Bo ng ny cnh bo rng bin tn l khong thc hin t ng reset li li , c th khi ng ng c . t ng kim sot reset, s dng nhm 31: AUTOMATIC RESET.

2014 (Note 1)

AUTOCHANGE

Bo ng ny cnh bo rng chc nng PFC t ng thay i l hot ng . kim sot PFC, s dng nhm 81: PFC CONTROL v PFC macro trn trang 78.

2015

PFC I LOCK

Bo ng ny cnh bo rng kha lin ng PFC l hot ng, c ngha l bin tn khng th khi ng sau y : bt k ng c (khi t ng thay i c s dng ). iu chnh tc ng c (khi t ng thay i c s dng).

2016/ 2017 2018 (Note 1)

RESERVED PID SLEEP

Khng s dng . Bo ng ny cnh bo rng chc nng ng PID l hot ng, c ngha l ng c c th tng tc khi chc nng ng PID kt thc. kim sot PID ng, s dng tham s 40224026 hoc 41224126.

2019 2020 2021

ID RUN RESERVED START ENABLE 1 MISSING

Thc hin ID Run. Khng s dng . Bo ng ny cnh bo rng Start Enable 1 tn hiu l thiu . n kim sot chc nng Start Enable 1, s dng tham s 1608. chnh xc ,kim tra : cu hnh u vo s. ci t truyn thng .

2022

START ENABLE 2 MISSING

Bo ng ny cnh bo rng Start Enable 2 tn hiu l thiu. n kim sot chc nng Start Enable 2, s dng tham s 1609. chnh xc ,kim tra: cu hnh u vo s. ci t truyn thng.

2023 2024

EMERGENCY STOP ENCODER ERROR

Dng khn cp c kch hot . Bin tn khng pht hin tn hiu b m ha hp l. kim tra v chnh xc : c b m ha xung v kt ni ph hp (ngc dy, kt ni lng hoc ngn mch ). mc in p logic l ngoi pham vi quy nh . vic lm v kt ni ng Pulse Encoder giao din Module, OTAC-01. sai gi tr nhp trong tham s 5001 PULSE NR. Mt gi tr sai s ch c xc nh nu li ny c tnh dn ln hn 4 ln so vi nh gi ca ng c . b m ha xung khng c s dng, nhng tham s 5002 ENCODER ENABLE =1 (ENABLE).

2025

FIRST START

Tn hiu rng bin tn ang s dng mt c tnh First Start c tnh ca ng c . iu ny bnh thng thi gian u ng c chy sau khi tham s ng c c nhp hoc thay i. Xem tham s 9910 ID RUN cho mt m t ca m hnh ng c. Khng s dng .

2026

RESERVED

Diagnostics

ACS550 Users Manual

253

Alarm code 2027

Display USER LOAD CURVE START DELAY

Description Bo ng ny cnh bo rng iu kin quy nh bi tham s 3701 USER LOAD C MODE hp l lu hn mt na ca thi gian xc nh bi 3703 USER LOAD C TIME. Hin th trong khi tr khi ng. xem tham s 2113 START DELAY.

2028

Ch 1. ngay c khi u ra relay c cu hnh cho bit iu kin bo ng (e.g. tham s 1401 RELAY OUTPUT 1 = 5 (ALARM) hoc 16 (FLT/ALARM)), bo ng ny khng c ch th bi u ra relay .

Alarm codes (Basic Control Panel) Basic Control Panel cho bit bng iu khin bo ng vi mt m s, A5xxx. Bng sau lit k cc m s bo ng v m t .
Code 5001 5002 5010 5011 5012 5013 5014 5015 5018 5019 5020 5021 5022 5023 5024 5025 5026 5027 5028 5029 5030 5031 5032 5040 5041 5042 5043 5044 Bin tn khng p ng . Thng tin giao tip khng tng thch vi bin tn . Tham s sao lu tp tin ca bng iu khin b hng. Bin tn c iu khin t mt ngun khc . Hng xoay b kha . Nt nhn b v hiu ha, bi v c ch khi ng . Nt nhn b v hiu ha, bi v bin tn b li. Nt nhn b v hiu ha, bi v ch cc b b kha . Gi tr mc dnh tham s khng th tm thy . Vit mt gi tr khc khng l b cm (ch c th vit gi tr l khng ). Nhm hoc tham s khng tn ti hoc gi tr tham s khng ph hp . Nhm hoc tham s l n . Nhm hoc tham s l bo v vit . Sa i l khng cho php trong khi bin tn ang chy . Bin tn ang bn, hy th li . Vit khng c php trong khi trong khi ti ln hoc ti v c tin hnh. Gi tr l ti hay di mc gii hn thp . Gi tr l ti hay di mc gii hn cao . Gi tr khng hp l khng ph hp vi bt k gi tr trong danh sch gi tr ring bit. B nh khng sn sng , hy th li. Yu cu khng hp l . Bin tn cha sn sng, e.g do in p DC thp . Thng s li c pht hin . Chn tham s ci t khng tm thy trong cc thng s sao lu hin hnh . Cc tham s sao lu vo b nh khng ph hp . Chn tham s ci t khng tm thy trong cc thng s sao lu hin hnh. Khng c ch khi ng c chp nhn. Phin bn thng s sao lu khng ph hp . Description

Diagnostics

254

ACS550 Users Manual

Code 5050 5051 5052 5060 5062 5070 5071 5080 5081 5083 5084 5085 5086 5087 5088 5089 5090 5091 5092 Cc thng s ti ln b hy b. Li tp tin c pht hin .

Description

Tham s c gn ti ln khng thnh cng . Tham s ti v b hy b. Tham s c gn ti v tht bi . Li ghi tham s bng iu khin sao lu c pht hin. Li c tham s bng iu khin sao lu c pht hin. Hot ng khng c php, bi v bin tn khng trong ch cc b . Hot ng khng c php, bi v mt li c kch hot . Hot ng khng c php, bi v tham s kha dang hot ng . Hot ng khng c php, bi v bin tn bn , hy th li . Download khng c php, bi v loi bin tn khng tng thch . Download khng c php, bi v m hnh bin tn khng ph hp . Download khng c php, bi v tham s thit lp khng khp . Li hot ng, bi v li b nh bin tn c pht hin . Li ti v, bi v li CRC c pht hin . Li ti v, bi v li x l d liu c pht hin. Li hot ng, bi v mt li tham s c pht hin . Li ti v, bi v tham s ci t l khng khp .

Diagnostics

ACS550 Users Manual

255

Maintenance

Cnh bo! Tm hiu chng Safety trn trang 5 trc khi thc hin bt k bo dng thit b . B qua cc hng dn an ton c th gy ra thng tch hoc t vong.

Maintenance intervals
Nu c lp t trong mi trng thch hp, bin tn cn bo dng rt t . Bng ny lit k cc khong bo hnh bo tr thng xuyn khuyn co ca ABB.
Maintenance Kim tra tng nhit v lm sch Interval Ph thuc vo bi ca mi trng (mi 612 thng) mi 6 nm mi ba nm. Instruction xem Heatsink trn trang 255.

Thay mi qut lm mt Thay mi vch ngn bn trong qut lm mt (IP54 / UL type 12 drives) Ci cch t in Thay th t (kch thc khung R5 v R6) Thay th pin trong Assistant Control Panel

xem Main fan replacement trn trang 256. xem Internal enclosure fan replacement trn trang 257. xem Reforming trn trang 258. xem Replacement trn trang 258. xem Battery trn trang 258.

Mi nm khi lu tr Mi chn n mi nm Mi mi nm

Heatsink
Cc sn b tng nhit tch t bi t khng kh lm mt . mt tng nhit nhiu bi tng nhit km hiu qu ti bin tn, nhiu kh nng li qu nhit. Trong mi trng bnh thng (khng bi, khng sch) kim tra tng nhit hng nm, kim tra thng xuyn hn trong mi trng bi . lm sch tng nhit nh sau (khi cn thit): 1. tho ngun in bin tn. 2. tho qut lm mt (xem phn Main fan replacement trn trang 256). 3. dng kh nn thi sch (khng m c) t di ln trn ng thi s dng mt my ht bi ti ca thng gi ht bi . Ch : nu c nguy c ca bi vo thit b tip gip, thc hin v sinh trong phng khc. 4. gn li qut lm mt. 5. khi phc li ngun in .

Maintenance

256

ACS550 Users Manual

Main fan replacement


Qut lm mt chnh ca bin tn c tui th khong 60 000 gi hot ng nhit ti a v ti bin tn cao . Tui th d kin tng gp i cho mi 10 C (18 F) gim nhit qut (nhit qut l chc nng ca mi trng xung quanh v ti bin tn ). Qut hng c th d on bi ting n ngy cng tng t vng bi ca qut v tng dn nhit tn nhit mc d lm sch tng nhit. Nu bin tn hot ng trong mt phn quan trng ca quy trnh, nn thay th qut lm mt mt khi nhng triu chng ny bt u xut hin. Thay th qut lm mt c sn t ABB. Khng s dng ph tng khc vi quy nh ca ABB. Frame sizes R1R4 thay th qut : 1. tho ngun in bin tn . 2. tho np che bin tn . 3. i vi khung kch thc : R1, R2: nhn cng lc cht gi hai bn v bo v qut v, nht ln. R3, R4: nhn trn mc c t nm pha tri ca ch gn qut, v xoay qut ln v ra ngoi . 4. ngt kt ni cp qut. 5. lp t qut theo th t ngc li . 6. khi phc li ngun in . Frame sizes R5 and R6 thay th qut: 1. tho ngun in bin tn. 2. tho cc c gn qut . 3. tho qut : R5: xoay qut ra ngoi trn bng l ca n. R6: ko qut ra . 4. ngt kt ni cp qut . 5. lp t qut theo th t ngc li. 6. khi phc li ngun in. mi tn trong qut cho thy hng v lng khng kh lun chuyn .
X0022 X5023 X0021

3 4

Bottom view (R5) 3

Bottom view (R6)

Maintenance

ACS550 Users Manual

257

Internal enclosure fan replacement


IP54 / UL loi 12 v c mt qut b sung bn trong lu thng khng kh bn trong v .

Frame sizes R1R4 thay th qut bn trong kch thc khung R1 n R3 (nm u bin tn) v R4 (nm pha trc bin tn ): 1. tho ngun in bin tn. 2. tho v mt trc. 3. ngn cha qut lm mt ti ch c gai gi li cc kp mi gc. Nhn c 4 kp v hng trung tm nh cc ngnh.
3 5

R1R3

4. khi cc kp/ngnh l c lp, ko ngn cha ln tho ra t bin tn . 5. ngt kt ni cp qut. 6. lp t qut theo th t ngc li, lu rng : dng kh qut i ln (tham kho mi tn trn qut ). cc dy in an ton l nm pha trc . cc rnh ngn cha nm gc phi pha sau . cc kt ni qut ch cn chuyn tip ca qut ti u ca bin tn. Frame sizes R5 and R6 thay th qut bn trong trong kch thc khung R5 hoc R6: 1. tho ngun in bin tn. 2. tho v mt trc. 3. nhc qut ra v ngt kt ni cp . 4. lp t qut theo th t ngc li. 5. khi phc li ngun in.
R4

FM

3AUA000000404

Maintenance

258

ACS550 Users Manual

Capacitors
Reforming T in lin kt DC bin tn cn phi c ci t li (re-aged) nu bin tn khng hot ng trong hn mt nm. Nu khng ci cch, t in c th b hng khi bin tn bt u hot ng. do ngh ci cch t in mi nm mt ln . xem phn Serial number trn trang 13 lm th no kim tra xem ngy sn xut t cc s hin th trn nhn bin tn . i vi thng tin v ci cch t in, tham kho Guide for Capacitor Reforming in ACS50/150/350/550 [3AFE68735190 (English)], c sn trn internet (i n www.abb.com v nhp m trong khu vc tm kim ). Replacement Bin tn s dng mch trung gian mt s t in. tui th ca t t 35 00090 000 ty thuc vo ti ca bin tn v nhit mi trng. Cuc sng ca t c th ko di bng cch h thp nhit mi trng xung quanh. khng th d on c hng t. t hng thng theo sau hng u vo ngun in nh t cu ch hoc li ngt . lin h ABB nu nghi ng hng t in . thay th cho c khung R5 v R6 l c sn t ABB. khng s dng ph tng khc vi quy nh ca ABB.

Control panel
Cleaning S dng mt ming vi mm m lm sch bng iu khin . Trnh cc cht ty ra c th lm m ca s hin th. Battery Mt pin ch c th s dng trong Assistant Control Panels c chc nng ng h c sn v kch hot . pin gi cho cc hot ng ng h b nh trong thi gian gin on ngun in . Cuc sng ca pin ln hn 10 nm. tho pin, s dng mt ng tin xoay np gi pin mt sau ca bng iu khin. thay pin mi loi CR2032. Ch : pin khng cn thit cho bt k bng iu khin hoc chc nng bin tn, ngoi tr ng h .

Maintenance

ACS550 Users Manual

259

Technical data

Ratings
Bi m loi , bng di y cung cp phm vi cho ACS550 iu chnh tc ng c AC bao gm : loi IEC loi NEMA ( t bng ) kch thc khung . Ratings, 208240 V drives Tiu ct vit tc c m t trong phn Symbols trn trang 261.
Type code ACS550-x1see below -04A6-2 -06A6-2 -07A5-2 -012A-2 -017A-2 -024A-2 -031A-2 -046A-2 -059A-2 -075A-2 -088A-2 -114A-2 -143A-2 -178A-2 -221A-2 -248A-2 4.6 6.6 7.5 11.8 16.7 24.2 30.8 46.2 59.4 74.8 88.0 114 143 178 221 248 I2N A Normal use PN kW 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 PN hp 3.5 4.6 6.6 7.5 11.8 16.7 24.2 30.8 46.2 59.4 74.8 88.0 114 150 178 192 I2hd A 0.55 0.75 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 Heavy-duty use Phd kW 0.75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 Phd hp Frame size

in p cung cp 3 pha, 208240 V R1 R1 R1 R1 R1 R2 R2 R3 R3 R4 R4 R4 R6 R6 R6 R6


00467918.xls B

Technical data

260

ACS550 Users Manual

Ratings, 380480 V drives Tiu ct vit tc c m t trong phn Symbols trn trang 261.
Type code ACS550-x1see below -03A3-4 -04A1-4 -05A4-4 -06A9-4 -08A8-4 -012A-4 -015A-4 -023A-4 -031A-4 -038A-4 -044A-4 (Note 3) -045A-4 (Note 3) -059A-4 -072A-4 -077A-4 (Note 4) -078A-4 (Note 4) -087A-4 (Note 5) -096A-4 (Note 5) -097A-4 -124A-4 (Note 6) -125A-4 (Note 6) -157A-4 -180A-4 -195A-4 -246A-4 3.3 4.1 5.4 6.9 8.8 11.9 15.4 23 31 38 44 45 59 72 77 77 87 96 97 124 125 157 180 195 245 I2N A 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 22 30 37 Note 2 Note 2 45 45 Note 2 55 55 75 90 110 132 Normal use PN kW 1.5 2 Note 1 3 5 7.5 10 15 20 25 30 30 40 50 60 60 Note 1 75 75 100 100 125 150 Note 1 200 PN hp 2.4 3.3 4.1 5.4 6.9 8.8 11.9 15.4 23 31 38 38 44 59 65 72 77 77 77 96 96 124 156 162 192 I2hd A 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 18.5 22 30 Note 2 Note 2 37 37 Note 2 45 45 55 75 90 110 Heavy-duty use Phd kW 1 1.5 Note 1 3 3 5 7.5 10 15 20 25 25 30 40 50 50 Note 1 60 60 75 75 100 125 Note 1 150 Phd hp Frame size

in p cung cp 3 pha , 380480 V R1 R1 R1 R1 R1 R1 R2 R2 R3 R3 R4 R3 R4 R4 R5 R4 R4 R5 R4 R6 R5 R6 R6 R6 R6


00467918.xls B

1. khng c sn trong ACS550-U1 series. 2. khng c sn trong ACS550-01 series. 3. ACS550-01-045A-4 (R3 mt kch c khung) thay th ACS550-01-044A-4 (ngng sn xut 2007). 4. ACS550-U1-078A-4 ( R4 mt kch c khung) thay th ACS550-U1-077A-4 (ngng sn xut 2007). 5. ACS550-01-087A-4 ( R4 mt kch c khung) thay th ACS550-01-096A-4 (ngng sn xut 2007). 6. ACS550-01-125A-4 ( R5 mt kch c khung) thay th ACS550-01-124-4 (ngng sn xut 2007).

Technical data

ACS550 Users Manual

261

Ratings, 500600 V drives Tiu ct vit tc c m t trong phn Symbols trn trang 261.
Type code ACS550-U1see below -02A7-6 -03A9-6 -06A1-6 -09A0-6 -011A-6 -017A-6 -022A-6 -027A-6 -032A-6 -041A-6 -052A-6 -062A-6 -077A-6 -099A-6 -125A-6 -144A-6 2.7 3.9 6.1 9.0 11 17 22 27 32 41 52 62 77 99 125 144 I2N A 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 Normal use PN kW 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 PN hp 2.4 2.7 3.9 6.1 9.0 11 17 22 27 32 41 52 62 77 99 125 I2hd A 1.1 1.5 2.2 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 Heavy-duty use Phd kW 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 Phd hp Frame size

in p cung cp 3 pha, 500600 V (Note 1) R2 R2 R2 R2 R2 R2 R3 R3 R4 R4 R4 R4 R6 R6 R6 R6


00467918.xls B

1. khng c sn trong ACS550-01 series.

Symbols
Typical ratings: Normal use (10% kh nng qu ti ) I2N Dng in lin tc rms. 10% cho php qu ti cho mt pht trong mi pht . PN Cng sut c trng ng c trong s dng bnh thng. Phn loi cng sut kw p dng cho hu ht cc ng c IEC, 4-cc. loi m lc p dng cho hu ht cc ng c 4-cc NEMA. Heavy-duty use (50% kh nng qu ti) I2hd Dng in lin tc rms. 50% cho php qu ti cho mt pht khng lp li mi mi pht. Phd Cng sut c trng ng c trong s dng bnh thng. Phn loi cng sut kw p dng cho hu ht cc ng c IEC, 4-cc. loi m lc p dng cho hu ht cc ng c 4-cc NEMA.

Sizing Phn loi dng in l nh nhau khng ph thuc vo in p cung cp trong vng phm vi in p. t c cng sut ng c cao nht nh trong bng, phm vi dng in ca bin tn phi cao hn hoc bng phm vi dng in ng c. Cng lu rng : phn loi p dng cho nhit mi trng xung quanh l 40 C (104 F) cng sut ti a cho php trn trc ng c c gii hn n 1.5 Phd. Nu gii hn ny b vt qu, momen xon v dng in ng c t ng c hn ch. Chc nng bo v u vo cu o ca bin tn chng li qu ti .

Technical data

262

ACS550 Users Manual

Derating Dung lng ti (dng in v cng sut) gim cho tnh trng nht nh, nh mc nh di y. Trong tnh trng ny, ni cng sut y ng c l cn thit, qu c bin tn gim gi tr ti cung cp dung lng ti . v d, nu ng dng ca bn yu cu 15.4 A dng in ng c v 8 kHz chuyn i tn s, bin tn tnh ton cc yu cu thch hp nh sau y :
kch c yu cu ti thiu = 15.4 A / 0.80 = 19.25 A trong : 0.80 l gim ti cho 8 kHz chuyn i tn s (xem phn Switching frequency derating trn trang 262).

tm I2N bng phn loi (bt u t trang 259), cc bin tn sau vt qu yu cu I2N ca 19.25 A: ACS550-x1-023A-4, hoc ACS550-x1-024A-2. Temperature derating Trong khong nhit +40 C50 C (+104 F122 F), dng in nh mc u ra gim ti 1% mi 1 C (1.8 F) trn +40 C (+104 F). tnh ton u ra dng in bng cch nhn dng in trong bng phn loi bi cc yu t gim ti . V d nu nhit mi trng xung quanh l 50 C (+122 F), yu t gim ti l 100% - 1%/C 10 C = 90% hoc 0.90. Dng in u ra v sau 0.90 I2N hoc 0.90 I2hd. Altitude derating cao 10004000 m (330013,200 ft) trn mc nc bin, gim ti l 1% cho mi 100 m (330 ft). nu lp t cao hn 2000 m (6600 ft) trn mc nc bin , vui lng lin h vi i din ABB ca bn hoc vn phng i din bit thm thng tin. Single phase supply derating i vi bin tn 208240 V series, ngun cung cp mt pha c th c s dng. trong trng hp ny gim ti l 50%. Switching frequency derating Khi s dng 8 kHz chuyn i tn s (tham s 2606), hoc l : Derate PN/Phd v I2N/I2hd n 80% hoc thit lp tham s 2607 SWITCH FREQ CTRL = 1 (ON) cho php bin tn gim tn s nu /khi nhit bin tn vt qu 90 C. xem m t tham s 2607 bit thm chi tit . khi s dng 12 kHz chuyn i tn s (tham s 2606), hoc l : Derate PN/Phd and I2N/I2hd n 65% (n 50% cho 600 V, kch c khung R4, l cho ACS550-U1-032A-6 ACS550-U1-062A-6), V nhit mi trng xung quanh gim ti a n 30 C (86 F), V ch rng dng in c gii hn n gi tr ln nht ca I2hd, hoc thit lp tham s 2607 SWITCH FREQ CTRL = 1 (ON) cho php bin tn gim tn s nu /khi nhit bin tn vt qu 80 C. xem m t tham s 2607 bit thm chi tit.

Technical data

ACS550 Users Manual

263

Input power connections


Cnh bo ! khng hot ng bin tn ngoi phm vi in p danh nh u vo . qu p c th dn n h hi vnh vin n bin tn .

Input power specifications


Input power (mains) connection specifications 208/220/230/240 V AC 3-pha (hoc 1-pha) -15%+10% cho ACS550-x1-xxxx-2. 400/415/440/460/480 V AC 3-pha -15%+10% cho ACS550-x1-xxxx-4. 500/525/575/600 V AC 3-pha-15%+10% cho ACS550-U1-xxxx-6. Prospective shortcircuit current (IEC 629) Frequency Imbalance Fundamental power factor (cos phi1) Cable temperature rating Dng in ngn mch cho php cung cp trong tng lai cung cp l 100 kA m u vo cp ngun ca bin tn c bo v vi cu ch . US: 100 000 AIC. 4863 Hz Max. 3% ca danh nh pha n u vo in p pha 0.98 (ti ti danh nh) 90 C (194 F) nh gi nh nht

Voltage (U1)

Disconnecting device for isolation Lp t u vo ngt kt ni thit b bng tay (ngt kt ni ngun in) gia ngun in p AC v bin tn . cc thit b ngt kt ni phi l loi c th kha n v tr m cho vic lp t v bo tr . chu u : p ng tiu chun ca lin minh chu u , theo tiu chun EN 60204-1, an ton my mc , cc thit b ngt kt ni phi l mt trong cc loi sau y : mt cu dao phn cch ca s dng loi AC-23B (EN 60947-3) mt dao cch ly c cng tc ph trong tt c cc trng hp chuyn mch ph v mch np trc khi ng contactor chnh ca dao cch ly (EN 60947-3) mt cu dao cch ly thch hp cho ph hp vi EN 60947-2. cc khu vc khc: cc thit b kt ni phi ph hp vi p dng quy nh an ton . Fuses Bo v mch nhnh phi c cung cp bi ngi dng cui v kch thc mi quc gia v tiu chun in a phng. Cc bng sau y cung cp khuyn co cho cu ch bo v ngn mch trn u vo ca bin tn .

Technical data

264

ACS550 Users Manual

Cu ch, bin tn 208240 V


ACS550-x1see below -04A6-2 -06A6-2 -07A5-2 -012A-2 -017A-2 -024A-2 -031A-2 -046A-2 -059A-2 -075A-2 -088A-2 -114A-2 -143A-2 -178A-2 -221A-2 -248A-2 Input current A 4.6 6.6 7.5 11.8 16.7 24.2 30.8 46.2 59.4 74.8 88.0 114 143 178 221 248 80 100 125 200 250 315 40 63 16 25 15 25 30 40 60 80 100 110 150 200 250 300 350 JJS-15 JJS-25 JJS-30 JJS-40 JJS-60 JJS-80 JJS-100 JJS-110 JJS-150 JJS-200 JJS-250 JJS-300 JJS-350
00467918.xls B

Input power (mains) fuses IEC 269 gG (A) 10 UL Class T (A) 10 Bussmann type JJS-10

Cu ch, bin tn 380480 V


ACS550-x1see below -03A3-4 -04A1-4 -05A4-4 -06A9-4 -08A8-4 -012A-4 -015A-4 -023A-4 -031A-4 -038A-4 -044A-4 -045A-4 -059A-4 -072A-4 -077A-4 -078A-4 -087A-4 -096A-4 -097A-4 Input current A 3.3 4.1 5.4 6.9 8.8 11.9 15.4 23 31 38 44 45 59 72 77 77 87 96 97 125 125 JJS-125 63 80 80 90 100 JJS-80 JJS-90 JJS-100 25 35 50 16 20 30 40 50 60 JJS-20 JJS-30 JJS-40 JJS-50 JJS-60 15 JJS-15 Input power (mains) fuses IEC 269 gG (A) 10 UL Class T (A) 10 Bussmann type JJS-10

Technical data

ACS550 Users Manual

265

ACS550-x1see below -124A-4 -125A-4 -157A-4 -180A-4 -195A-4 -246A-4

Input current A 124 125 157 180 195 245

Input power (mains) fuses IEC 269 gG (A) 160 UL Class T (A) 175 Bussmann type JJS-175

200 250

200 250

JJS-200 JJS-250

350

JJS-350
00467918.xls B

Cu ch, bin tn 500600 V


ACS550-U1see below -02A7-6 -03A9-6 -06A1-6 -09A0-6 -011A-6 -017A-6 -022A-6 -027A-6 -032A-6 -041A-6 -052A-6 -062A-6 -077A-6 -099A-6 -125A-6 -144A-6 Input current A 2.7 3.9 6.1 9.0 11.0 17.0 22.0 27 32 41 52 62 77 99 125 144 125 160 200 50 60 80 50 60 80 100 150 175 200 JJS-50 JJS-60 JJS-80 JJS-100 JJS-150 JJS-175 JJS-200
00467918.xls B

Input power (mains) fuses IEC 269 gG (A) 10 UL Class T (A) 10 Bussmann type JJS-10

16

15

JJS-15

25

25

JJS-25

35

40

JJS-40

Emergency stop devices Thit k tng th ca tin trnh lp t phi bao gm cc thit b dng khn cp v bt k cc thit b khc c th l cn thit . nhn STOP trn bng iu khin ca bin tn l khng : to ra mt dng khn cp ca bin tn tch ri bin tn vi cc nguy him tim nng . Input power cables/wiring Dy dn u vo bt k c th ca : mt cp dn 4 rut (3 pha v t/bo v ni t). l chn l khng cn thit . 4 dy dn cch in thng qua ng dn .

Technical data

266

ACS550 Users Manual

Kch thc dy theo quy nh an ton ca a phng, in p u vo ph hp v dng in ti ca bin tn. trong mi trng hp, cc dy dn phi nh hn gii hn ti a xc nh bi kch thc u ni (xem phn Drives power connection terminals trn trang 268). Bng di y lit k cc loi cp ng v nhm cho dng ti khc nhau. nhng khuyn ngh ny ch p dng cho cc iu kin c lit k trn cng ca bng .
IEC Cn c vo : EN 60204-1 and IEC 60364-5-2/2001 cch in PVC 30 C (86 F) nhit mi trng 70 C (158 F) nhit b mt cp vi l chn ng tm khng c qu 9 cp trn cp thang cnh nhau. Max. load current A 14 20 27 34 47 62 79 98 119 153 186 215 249 284 Cu cable mm2 31.5 32.5 34 36 310 316 325 335 350 370 395 3120 3150 3185 91 117 143 165 191 218 257 274 285 350 370 395 3120 3150 3185 3240 3 (350) 2 (395) Max. load current A Al cable mm2 Cn c vo: NEC bng 310-16 cho dy ng 90 C (194 F) cch in dy 40 C (104 F) nhit mi trng khng qu 3 dy dn mang dng in trong ng bo v hoc cp , hoc t (chn trc tip) cp ng vi l chn ng tm. Max. load current A 22.8 27.3 36.4 50.1 68.3 86.5 100 118 137 155 178 205 237 264 291 319 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 MCM or 2 1 300 MCM or 2 1/0 350 MCM or 2 2/0 Cu wire size AWG/kcmil NEC

Aluminium cable cannot be used with frame sizes R1R5 because of its lower capacity.

Ground connections i vi quy nh an ton, ng hot ng v gim pht x in t / u d, bin tn v ng c phi dc ni t ti v tr lp t. dy dn in phi kch thc theo yu cu ca quy nh an ton . ngun cp l chn phi c kt ni n bin tn u ni PE p ng quy nh an ton.

Technical data

ACS550 Users Manual

267

cp l chn ngun thch hp cho s dng nh thit b ni t ch khi kch thc l chn y kch thc theo yu cu quy nh an ton . trong lp t nhiu bin tn, khng kt ni thit b u cui trong cc bin tn . Corner grounded TN systems Cnh bo ! khng c gn lp t hoc g b EM1, EM3, F1 hoc F2 c trong khi ngun c p dng u vo thit b u cui bin tn. Gc h thng ni t TN c quy nh trong bng sau. Trong h thng nh vy, ngt kt ni ni t bn trong kt ni bng cch g b vt (cng lm iu ny nu cu hnh nn tng ni t l khng r ): ACS550-01, kch thc khung R1R4: g b cc c EM1 v EM3 (xem phn Power connection diagrams trn trang 20). ACS550-U1, kch thc khung R1R4: g b cc c EM1 bin tn chuyn vi g b EM3 (xem phn Power connection diagrams trn trang 20). kch thc khung R5R6: g b cc c F1 v F2 (xem phn Power connection diagrams, trn trang 21).

Corner grounded TN systems EM1, EM3, F1 and F2 must be out Ni t gc ca tam gic L2 L3 Mt pha , Ni t ti im cui N L3 L3 L1 3 pha Variac m khng ni t c nh dy trung tnh L1 L1 L2 L2 L1 Ni t ti im gia ca mt nhnh tam gic L1

L2 L3

Cc vt (M416) lm kt ni ni t bn trong b kh pht x t tnh in t. trong EMC (tnhtng thch in t) l mt mi quan tm , v h thng l ni t i xng , cc vt c th c lp t . tham kho, biu bn phi minh ha h thng ni t TN i xng c cn c .

L1

L2 L3

Technical data

268

ACS550 Users Manual

IT systems Cnh bo ! ng c gn lp t hoc g b c EM1, EM3, F1 hoc F2 trong khi ngun c p dng u vo thit b u cui bin tn. i vi h thng IT [mt h thng ngun in khng c ni t hoc in tr ni t cao (hn 30 ohm) h thng ngun in ]: ngt kt ni ni t n b lc bn trong EMC : ACS550-01, kch thc khung R1R4: g b cc c EM1 v EM3 (xem phn Power connection diagrams trn trang 20). ACS550-U1, kch thc khung R1R4: g b cc c EM1 bin tn chuyn vi g b EM3 (xem phn Power connection diagrams trn trang 20). kch thc khung R5R6: g b cc c F1 v F2 (xem phn Power connection diagrams, trn trang 21). Where EMC yu cu c , kim tra tha bc x lan truyn n li in p thp ln cn. trong mt s trng hp, s ln p t nhin trong my bin p v cp l . nu nghi ng, s dng my bin p cung cp vi cch ly gia s cp v th cp . khng lp t b lc RFI/EMC bn ngoi . S dng mt lc EMC ni t ngun in u vo thng t lc , m c th lm nguy him v c th lm h bin tn . Drives power connection terminals Bng sau y cung cp chi tit k thut ngun in bin tn kt ni n thit b u cui .
U1, V1, W1 U2, V2, W2 BRK+, UDC+ terminals Max. terminal size mm2 R11 R21 R31 R41 R51 R6
1

Frame size

Earthing PE terminal Max. terminal size mm2 4 10 16 35 70 95 AWG 10 8 6 2 2/0 4/0 Nm 1.4 1.4 1.8 2 15 8 Torque lb-ft 1 1 1.3 2 11 6
00467918.xls B

Torque Nm 1.4 1.4 1.8 2 15 40 lb-ft 1 1 1.3 1.5 11 30

AWG 8 6 3 1/0 2/0 350 MCM

6 10 25 50 70 185

Cp nhm khng c s dng vi cc kch c khung R1R5 bi v cng sut ca n thp hn .

Technical data

ACS550 Users Manual

269

Power terminal considerations R6 frame size Cnh bo ! i vi R6 u ni ngun in, nu c trn u ni cc gn dy c cung cp, h ch c th s dng cho kch thc dy 95 mm2 (3/0 AWG) hoc ln hn. Cc dy dn nh hn s lng v c th lm h bin tn. H yu cu u cos vng nh m t di y .

Crimp-on ring lugs Trn kch thc khung R6, nu c trn cc u ni c cung cp nhng kch thc cp c s dng nh hn 95mm2 (3/0 AWG), hoc khng c c trn cc u ni c cung cp ti tt c, s dng cc u cos vng theo m t di y . 1. chn u cos vng thch hp t bng sau y . . 2. g c trn u ni cc, nu c cung cp . 3. gn cht u cos vng n cc u cui ca cp . 4. tch bit cui ca cos vng vi bng keo cch in hoc mng co PVC. 5. gn cht u cos vng vo bin tn.
Wire size mm2 kcmil/ AWG 6 Manufacturer Ring lug Crimping tool MY29-3 ILC-10 MY29-3 MT-25 MY29-3 IDT-12 MT-25 MY29-3 IDT-12 MT-25 TBM-8 MY29-3 IDT-12 MT-25 TBM-8 No. of crimps 1 2 1 1 2 1 1 2 1 1 3 2 1 1 3
X60002

5 3 4

16

Burndy Ilsco Burndy Ilsco Burndy

YAV6C-L2 CCL-6-38 YA4C-L4BOX CCL-4-38 YA2C-L4BOX CRC-2 CCL-2-38 YA1C-L4BOX CRA-1-38 CCL-1-38 54148 YA25-L4BOX CRB-0 CCL-1/0-38 54109

25

35

Ilsco Ilsco Burndy

50

Ilsco Ilsco Thomas & Betts Burndy

55

1/0

Ilsco Ilsco Thomas & Betts

Technical data

270

ACS550 Users Manual

Wire size mm2 kcmil/ AWG Manufacturer Ring lug

Crimping tool MY29-3 IDT-12 MT-25 TBM-8 MY29-3 IDT-12 MT-25 TBM-8 MY29-3 IDT-12 MT-25 TBM-8

No. of crimps 2 1 1 3 2 1 1 3 2 1 2 4 2

Burndy 70 2/0 Ilsco Ilsco Thomas & Betts Burndy 95 3/0 Ilsco Ilsco Thomas & Betts Burndy 95 3/0 Ilsco Ilsco Thomas & Betts

YAL26T38 CRA-2/0 CCL-2/0-38 54110 YAL27T38 CRA-3/0 CCL-3/0-38 54111 YA28R4 CRA-4/0 CCL-4/0-38 54112

Screw-on terminal lugs S dng phng php sau y gn cp nu c trn u ni cc gn dy c cung cp v kch c cp l 95 mm2 (3/0 AWG) hoc ln hn . 1. gn cht cung cp c trn cc gn dy n u cui ca cp . 2. gn cht c trn cc gn dy n bin tn .
1

X60003

X60001

Technical data

ACS550 Users Manual

271

Motor connections
Cnh bo ! khng bao gi kt ni ngun in n u ni ng ra ca bin tn: U2, V2 hoc W2. Kt ni in p c p dng cho u ra c th gy h hng vnh vin n bin tn . nu cn chuyn mch thng xuyn, s dng my mc thit b chuyn mch hoc contactor .

Cnh bo! Khng kt ni bt k ng c vi mt in p danh nh nh hn mt na in p u vo danh nh bin tn .

Cnh bo! Ngt kt ni bin tn trc khi tin hnh bt k np in p (Hi-Pot) th nghim kim tra in tr cch ly (Megger) trn ng c hoc cp ng c. Khng lm cc kim tra ny trn bin tn .

Motor connection specifications


Motor connection specifications Voltage (U2) Frequency Frequency resolution Current Field weakening point 0U1, 3-pha i xng, U max ti im trng suy yu 0500 Hz 0.01 Hz Xem phn Ratings trn trang 259. 10500 Hz Chn. xem c sn trong bng di y . 208240 V 380480 V 1, 4 and 8 kHz tt c loi tt c loi, tr ACS550-01-246A-4 ch 1 v 4 kHz tt c loi 12 kHz Kch thc khung R1R4 Kch thc khung R1R4, Tr ACS550-01-087A-4 v ACS550-U1-097A-4 Kch thc khung R2R4

Switching frequency

500600 V Cable temperature rating Maximum motor cable length

90 C (194 F) nh mc nh nht. Xem phn Motor cable length for 400 V drives trn trang 272 v Motor cable length for 600 V drives trn trang 273.

Technical data

272

ACS550 Users Manual

Motor cable length for 400 V drives Bng di y cho thy di cp ng c ti a cho bin tn 400 V vi chuyn i tn s khc nhau . cc v d cho vic s dng bng cng c xc nh .
Maximum cable length for 400 V drives EMC limits Second environment (category C31) Frame size R1 R2 R3 R4 R5 R6
1 2 3

Operational limits First environment (category C21) Basic unit 8 kHz m ft 1/4 kHz m ft 8/12 kHz m ft 330 330 With du/dt filters m ft

1 kHz m ft

4 kHz m ft

8 kHz m ft

1 kHz m ft

4 kHz m ft 980 330

300 980 300

300 980 300

980 300 980 300 980 300 980 100 980 300 980 75

300 980 100 330 100 30 98 245 245 200 200 200 660 100 660 100

150 490 250 820 820 980

980 300 980 300 300 980 300

300 980 300 100 100

245 75 75

330 250 300

980 300 980 300 330 100 330 330

980 300 980

75 245

660 100 330

100 330 100 330 100 330


3 3

100 330
3 3

300 980 1502 4902 300 980 300 980 1502 4902 300 980

100 330

100 330 100

330

Xem cc iu khong mi trong phn IEC/EN 61800-3 (2004) Definitions trn trang 292. 12 kHz chuyn i tn s l khng c sn . Khng kim tra .

Sine lc m rng hn na di cp .

Cnh bo ! s dng mt cp ng c c di ln hn qui nh trong bng trn c th gy h hng vnh vin bin tn. V d cho s dng bng :
Requirements R1 frame size, 8 kHz fsw, category C2 150 m (490 ft) cable R3 frame size, 4 kHz fsw, Category C3, 300 m (980 ft) cable Checking and conclusions Kim tra gii hn hot ng cho R1 v 8 kHz -> cho 150 m (490 ft) cp du/dt lc l cn thit. kim tra gii hn EMC -> EMC yu cu cho loi C2 p ng vi 150 m (490 ft) cp. Kim tra gii hn hot ng cho R3 v 4 kHz -> a 300 m (980 ft) cp khng th s dng ngay c vi b lc du/dt. Mt b lc sine phi c s dng nh git in p cp phi c a vo tnh ton trong lp t . kim tra gii hn EMC -> EMC yu cu cho loi C3 p ng vi 300 m (980 ft) cp. R5 frame size, 8 kHz fsw, Category C3, 150 m (490 ft) cable Kim tra gii hn hot ng cho R5 v 8 kHz -> cho a 150 m (490 ft) cp n v c bn l . kim tra gii hn EMC -> EMC yu cu cho loi C3 khng p ng vi 300 m (980 ft) cp. Cu hnh ci t l khng th . mt phng n EMC c khuyn khch khc phc tnh trng. Kim tra gii hn hot ng cho R6 v 4 kHz -> cho 150 m (490 ft) cp n v c bn l . EMC gii hn khng cn khng cn kim tra nh khng yu cu EMC .

R6 frame size, 4 kHz fsw, EMC limits not applicable, 150 m (490 ft) cable

Technical data

ACS550 Users Manual

273

Motor cable length for 600 V drives Bng di y cho thy di cp ng c ti a cho bin tn 600 V vi chuyn i tn s khc nhau. Nh bin tn 600 V khng chp thun CE, chiu di cp cho gii hn EMC l khng nht nh .
Maximum cable length for 600 V drives Operational limits Frame size R2 R3R4 R6
2

1/4 kHz m 100 200 300 ft 330 660 980 m

8/12 kHz ft 330 330 4902

100 100 1502

12 kHz switching frequency is not available.

Cnh bo ! s dng cp ng c di hn quy nh trong bng trn c th gy ra h hng cho bin tn .

Motor thermal protection Theo quy nh, ng c phi c bo v khi qu ti nhit ,dng in phi c tt khi pht hin qu ti . bin tn bao gm chc nng bo v nhit ng c v chuyn i tc ngun in khi cn thit . ty thuc vo gi tr tham s bin tn (xem Group 35: MOTOR TEMP MEAS), chc nng hoc l gim st tnh ton gi tr nhit (da trn m hnh nhit ng c ) hoc ch dn nhit thc t a ra bi cm bin nhit ng c. Ngi dng c th iu chnh m hnh nhit xa hn bng cch cung cp b sung ng c v cc d liu ti. cc cm bin nhit ph bin nht l : kch thc ng c IEC180225: chuyn i nhit (e.g. Klixon) kch thc ng c IEC200250 v ln hn: PTC hoc PT100. Ground fault protection ACS550 pht hin li logic ni t ni b trong bin tn, ng c, hoc cp ng c. li logic ny : l khng an ton c nhn hoc phng chy cha chy c th v hiu ha bng cch s dng tham s 3017 EARTH FAULT c th nhn bi dng in r (u vo ngun in vi t) lin kt vi cp ng c c in dung cao.

Technical data

274

ACS550 Users Manual

Grounding and routing Motor cable shielding Cp ng c cn che chn bng cch s dng ng dn, cp bc thp hoc l chn thp. ng dn khi s dng ng dn : mi ni dng tm ghp vi mt dy dn ni t n ng dn trn mi bn ca b ni . qun bng keo ng dn chy n bin tn . s dng ng dn ring chy cho cp ng c (ring bit ngun in u vo v cp iu khin ). s dng ng dn chy ring bit cho tng bin tn . cp bc thp khi s dng cp bc thp : s dng 6 dy dn (3 pha v 3 grounds), loi MC gn sng lin tc gip cp nhm vi ni t i xng. cp ng c bc thp c th tch ring mt cp vi cp ngun u vo, nhng khng phi vi cp iu khin . l chn cp bit chi tit cp l chn, xem phn Motor cable requirements for CE & C-Tick compliance trn trang 274. Grounding Xem phn Ground connections trn trang 266. Tun th lp t CE v lp t pht x EMC phi c nh nht Xem phn Effective motor cable screens trn trang 275. Drives motor connection terminals Cp l ng c v u ni ngun in u vo c cng thng s k thut. xem phn Drives power connection terminals trn trang 268. Motor cable requirements for CE & C-Tick compliance Cc yu cu trong phn ny p dng cho CE hoc C-Tick compliance. Minimum requirement (CE & C-Tick) Cp ng c phi l cp 3 pha i xng vi mt dy PE ng tm hoc mt cp dn 4 dy vi mt cp l chn ng tm , tuy nhin, mt dy dn i xng PE l lun lun khuyn khch . Hnh di y cho thy cc yu cu ti thiu cho lc cp ng c (v d , MCMK, NK Cables).
Insulation jacket Copper wire screen Inner insulation

Cable core

Technical data

ACS550 Users Manual

275

Recommendation for conductor layout Hnh di y so snh cc tnh nng b tr dy dn trong cp ng c .


Recommended (CE & C-Tick) Symmetrical shielded cable: three phase conductors and a concentric or otherwise symmetrically constructed PE conductor, and a shield PE conductor and shield Shield PE Allowed (CE & C-Tick) A separate PE conductor is required if the conductivity of the cable shield is < 50% of the conductivity of the phase conductor. Shield

Shield Not allowed for motor cables (CE & C-Tick) A four-conductor system: three phase conductors and a protective conductor, without a shield. PE Allowed for motor cables with phase conductor cross section up to 10 mm2.

Effective motor cable screens Nguyn tc chung cho hiu qu lc cp l: ci tin v chng cp c lc , mc pht x thp hn . hnh di y cho thy mt v d ca hiu qu cu to (v d lflex-Servo-FD 780 CP, Lappkabel or MCCMK, NK Cables).
Insulation jacket Inner insulator L2

L1 Braided metallic screen L3

EN 61800-3 compliant motor cables Lc EMC hiu qu nht c th t c bng cch lm theo cc quy tc sau : cp ng c phi c hiu qu nh c m t trong phn Effective motor cable screens trn trang 275. dy lc cp ng c phi c gn vi nhau thnh mt nhm mch ( di nhm mch phi nh hn 5 ln chiu rng ca n) v kt ni n n u ni c nh du ( gc phi bn di bin tn ). cui ng c, b lc cp ng c phi c ni t 360 vi mt tuyn cp EMC, hoc b lc dy phi c xon vi nhau thnh mt b khng di hn chiu rng ca n 5 ln v kt ni vi u ni PE ca ng c . xem phn Motor cable length for 400 V drives, ct EMC limits trn trang 272 kim tra di cp ng c ti a v cn thit lc bin tn 400 V cho ph hp IEC/EN 61800-3.

Technical data

276

ACS550 Users Manual

Cnh bo ! khng s dng lc RFI/EMC trong h thng IT.

Technical data

ACS550 Users Manual

277

Brake components
Availability Phanh c sn cho bin tn ACS550 , bi kch c khung l : R1 v R2 mt phanh thng in bn trong l trang b tiu chun. Thm in tr thch hp c xc nh bng cch s dng phn sau . in tr c sn t ABB. R3R6 khng bao gm mt phanh thng in bn trong . Kt ni thng in v in tr , hoc n v phanh n u ni kin kt DC trn bin tn. lin h i din ABB cho cc b phn thch hp . Selecting the braking resistors (frame sizes R1 and R2) in tr phanh phi p ng 3 yu cu : tr khng phi lun cao hn gi tr nh nht RMIN xc nh cho loi bin tn trong bng sau . khng s dng tr khng thp hn gi tr ny . in tr phi thp to ra momen xon momg mun . t c momen xon phanh ti a ( ln hn 150% ti nng ca 110% ca ti danh nh ), in tr khng vt qu RMAX. Nu momen xon phanh ln nht l khng cn thit , gi tr in tr c th vt qu RMAX. cng sut nh mc in tr phi cao tiu tn cng sut phanh . yu cu ny lin quan n nhiu yu t : cng sut nh mc lin tc ti a cho cc in tr (s) mc m in tr thay i nhit (thi gian nhit in tr khng i) thi gian phanh ti a ON nu cng sut ti sinh (phanh) ln hn cng sut nh mc in tr, c mt gii hn thi gian ON , hoc qu nhit in tr trc khi bt u giai on OFF . thi gian phanh nh nht OFF nu cng sut ti sinh (braking) ln hn cng sut nh mc in tr, thi gian OFF phi ln in tr mt gia chu k ON .
Braking ON Braking OFF ON time OFF time Cycle time Duty cycle = ON time Cycle time

Time

nh cng sut phanh yu cu loi ca phanh (gim tc n khng vs. kim tra k ti) trong qu trnh gim tc n khng, cng sut c pht sinh gim iu n, trung bnh mt na ca nh cng sut . Cho kim tra k ti, phanh l chng li lc bn ngoi (v d nh trng lc) v cng sut phanh l hng s. tng s nhit lng kim tra k ti l gp i nhit to ra t gim tc n tc khng (cho cng mt momen xon cao nht v thi gian ON).

Technical data

278

ACS550 Users Manual

Power Avg. braking power overhauling load Avg. braking power during deceleration to zero Temperature 2x x

Deceleration curve

Overhauling load curve

Time

Time

Nhiu bin trong cc yu cu cui cng trn y l cch d dng nht gii quyt bng cch s dng bng sau y. trc tin , bn xc nh thi gian phanh ti a ON (ONMAX), thi gian phanh ti thiu OFF (OFFMIN) v loi ti (gim tc hoc kim tra ti). tnh chu k nhim v :
Duty cycle ONMAX (ONMAX + OFFMIN) 100%

trong bng thch hp, tm thy d liu ph hp nht cho d liu ca bn : ONMAX < c im k thut ct v Duty cycle < c im k thut ct tm hng ph hp vi bin tn ca bn. cng sut nh mc nh nht cho gim tc n khng l gi tr trong chn hng/ct. kim tra k ti, gp i nh gi ca dng/ct, hoc s dng ct lin tc ON . 208240 V drives
Resistance Type code ACS55001/U1see below Resistor1 minimum continuous power rating Deceleration-to-zero rating Pr3 Pr10 Pr30 Pr60 R MAX R MIN < 3 s ON < 10 s ON < 30 s ON < 60 s ON > 27 s OFF > 50 s OFF > 180 s OFF > 180 s OFF < 10% Duty < 17% Duty < 14% Duty < 25% Duty > 25% Duty ohm ohm W W W W Prcont Continuous ON > 60 s ON

Three-phase supply voltage, 208240 V -04A6-2 -06A6-2 -07A5-2 -012A-2 -017A-2 -024A-2 -031A-2
1

234 160 117 80 48 32 23

80 80 44 44 44 30 22

45 65 85 125 210 315 430

80 120 160 235 390 590 800

120 175 235 345 575 860 1175

200 280 390 570 950 1425 1940

1100 1500 2200 3000 4000 5500 7500

Resistor time constant specification must be > 85 seconds.

Technical data

ACS550 Users Manual

279

380480 V drives
Resistance Type code ACS55001/U1see below R MAX R MIN Resistor1 minimum continuous power rating Deceleration-to-zero rating Pr3 Pr10 Pr30 Pr60 < 3 s ON < 10 s ON < 30 s ON < 60 s ON > 27 s OFF > 50 s OFF > 180 s OFF > 180 s OFF < 10% Duty < 17% Duty < 14% Duty < 25% Duty > 25% Duty W W W W Prcont Continuous ON > 60 s ON

ohm

ohm

Three-phase supply voltage, 380480 V -03A3-4 -04A1-4 -05A4-4 -06A9-4 -08A8-4 -012A-4 -015A-4 -023A-4
1

641 470 320 235 192 128 94 64

120 120 120 80 80 80 63 63

65 90 125 170 210 315 425 625

120 160 235 320 400 590 800 1175

175 235 345 470 575 860 1175 1725

285 390 570 775 950 1425 1950 2850

1100 1500 2200 3000 4000 5500 7500 11000

Resistor time constant specification must be > 85 seconds.

500600 V drive
Resistance Type code ACS550U1see below Resistor1 minimum continuous power rating Deceleration-to-zero rating Pr3 Pr10 Pr30 Pr60 R MAX R MIN < 3 s ON < 10 s ON < 30 s ON < 60 s ON > 27 s OFF > 50 s OFF > 180 s OFF > 180 s OFF < 10% Duty < 17% Duty < 14% Duty < 25% Duty > 25% Duty ohm ohm W W W W Prcont Continuous ON > 60 s ON

Three-phase supply voltage, 500600 V -02A7-6 -03A9-6 -06A1-6 -09A0-6 -011A-6 -017A-6
1

548 373 224 149 110 75

80 80 80 80 60 60

93 137 228 342 467 685

175 257 429 643 877 1286

257 377 629 943 1286 1886

425 624 1040 1560 2127 3119

1462 2144 3573 5359 7308 10718

Resistor time constant specification must be > 85 seconds.

Cnh bo ! khng bao gi s dng in tr phanh vi in tr nh hn gi tr quy nh nh nht cho cc bin tn c th . bin tn v thng in bn trong khng th s l qu dng gy ra bi in tr thp .

Symbols RMIN in tr nh nht cho php ca in tr phanh . RMAX in tr ln nht cho php nu momen phanh ln nht l cn thit .

Technical data

280

ACS550 Users Manual

Prx chu k ti da trn cng sut nh mc in tr trong phanh gim tc, trong x l thi gian ONMAX . Installing and wiring resistors Tt c cc in tr phi c lp t bn ngoi module bin tn trong mt ni m h c th tiu tn nhit . Cnh bo ! nhit b mt in tr rt cao, v khng kh chy t in tr rt nng. Vt liu gn in tr phanh phi khng d chy .. cung cp bo v tip xc bt ng vi in tr . m bo rng u vo cu ch bo v in tr cp , s dng in tr cp vi nh mc nh c s dng cho u vo ngun in bin tn . Chiu dy ti a ca dy cp in tr (s) l 10 m (33 ft). xem phn Power connection diagrams trn trang 20 cho im kt ni cp in tr . Mandatory circuit protection Thit lp sau y l cn thit cho an ton n lm gin on ngun cung cp chnh trong cc tnh hung li lin quan n bao gm ngn mch thng in : trang b bin tn vi contactor chnh. dy contactor m ra nu m nhit in tr (mt in tr qu nng m contactor). Di y l v d s ni dy n gin .
L1 L2 L3 Off Fuses 2 1

1 2 ACS550

3 4

5 6

13 On 14

3 4

U1 V1 W1 Q K1 Thermal switch (standard in ABB resistors)

Parameter set-up kch hot tnh nng phanh, chuyn i tt kim sot qu p bin tn [t tham s 2005 = 0 (DISABLE)].

Technical data

ACS550 Users Manual

281

Control connections
Control connection specifications
Control connection specifications Analog inputs and outputs Digital inputs Xem phn Control terminals table trn trang 22. Tr khng u vo s 1.5 kohm. in p ln nht cho u vo s l 30 V. Relays (digital outputs) Cable specifications Max. in p tip xc: 30 V DC, 250 V AC Max. dng in / cng sut tip xc: 6 A, 30 V DC; 1500 VA, 250 V AC Max. dng in lin tc: 2 A rms (cos = 1), 1 A rms (cos = 0.4) Ti nh nht: 500 mW (12 V, 10 mA) Vt cht tip xc: Silver-nickel (AgN) Cch ly gia u ra relay s, kim tra in p: 2.5 kV rms, 1 minute

Xem phn Control terminals table trn trang 22.

Control cables General recommendations S dng cp nhiu li vi mt dy ng nhiu nhnh b lc, nhit nh mc 60 C (140 F) hoc trn :

Hai l chn Example: JAMAK by Draka NK Cables

Mt l chn Example: NOMAK by Draka NK Cables

im cui, xon b lc li thnh mt b khng di hn 5 ln b rng ca n kt ni vi u ni X1-1 (cho cp I/O s v tng t ) hoc khc l X1-28 hoc X1-32 (cho cp RS485 ). u kia ca cp cha c ni . ng cp iu khin gim thiu bc x n cp : ng cng xa cng tt t ngun in u vo v cp ng c [t nht 20 cm (8 in)]. trng hp cp iu khin phi i qua dy cp in, m bo rng chng ang mt gc 90 l tt nht . dng li 20 cm (8 in) t cc bn ca bin tn . Trng hp s dng trn ln nhiu loi tn hiu trn cp ging nhau: khng dng chung cc tn hiu iu khin relay bng cch s dng hn 30 V v tn hiu iu khin khc trong cng cp. Run relay-iu khin tn hiu nh cp xon (c bit l nu in p > 48 V). Relayiu khin tn hiu thp hn 48 V c th chy trong cng mt cp tn hiu nh u vo tn hiu s .

Technical data

282

ACS550 Users Manual

Ch : khng bao gi trn ln tn hiu 24 V DC v 115/230 V AC trong dy cp .

Analog cables Khuyn ngh cho tn hiu tng t chy : s dng i l chn, cp cp xon . s dng mt cp l chn ring l cho mi tn hiu . khng s dng tr v chung cho cc tn hiu tng t khc nhau . Digital cables Khuyn ngh cho tn hiu s chy : mt i cp l chn l la chn tt nht , nhng che chn n, xon, nhiu cp cp cng c th c s dng . Control panel cable Nu bng iu khin c kt ni n bin tn vi cp, ch s dng loi cp 5 Patch chun ethernet. Chiu di ti a hiu chun p ng EMC l 3 m (9.8 ft). cp di hn d b nhiu in t v phi c ngi s dng hiu chun Xc minh rng yu cu EMC c p ng. trng hp yu cu chy di [c bit l chy di hn 12 m (40 ft)], s dng cng c chuyn i RS232/RS485 ti mi u v chy cp RS485 . Drives control connection terminals Bng sau y cung cp chi tit k thut cho cc thit b u cui ca bin tn .
Frame size Control Maximum wire size 1 mm2 All
1

Torque Nm 0.4 lb-ft 0.3

AWG 16

1.5

Values given for solid wires. For stranded wires, the maximum size is 1 mm2.

Efficiency
Khong 98% mc cng sut danh nh .

Technical data

ACS550 Users Manual

283

Cooling
Cooling specifications Method Requirement Qut bn trong, dng chy hng t di ln trn. Khong trng trn v di bin tn ACS550 l: 200 mm (8 in). khng gian trng l khng cn thit trn cc cnh bn ca bin tn ACS550 bin tn c th c gn cnh nhau .

Air flow, 208240 V drives Bng sau y lit k tn tht nhit v lng khng kh cn thit cho bin tn 208240 V .
Drive ACS550-x1-04A6-2 -06A6-2 -07A5-2 -012A-2 -017A-2 -024A-2 -031A-2 -046A-2 -059A-2 -075A-2 -088A-2 -114A-2 -143A-2 -178A-2 -221A-2 -248A-2 Frame size R1 R1 R1 R1 R1 R2 R2 R3 R3 R4 R4 R4 R6 R6 R6 R6 55 73 81 118 161 227 285 420 536 671 786 1014 1268 1575 1952 2189 W 189 249 276 404 551 776 973 1434 1829 2290 2685 3463 4431 5379 6666 7474 Heat loss BTU/hr 44 44 44 44 44 88 88 134 134 280 280 280 405 405 405 405 m3/h 26 26 26 26 26 52 52 79 79 165 165 165 238 238 238 238
000467918.xls B

Air flow ft3/min

Air flow, 380480 V drives Bng sau y lit k tn tht nhit v lng khng kh cn thit cho bin tn 380480 V .
Drive ACS550-x1-03A3-4 -04A1-4 -05A4-4 -06A9-4 -08A8-4 -012A-4 -015A-4 -023A-4 Frame size R1 R1 R1 R1 R1 R1 R2 R2 40 52 73 97 127 172 232 337 W 137 178 249 331 434 587 792 1151 Heat loss BTU/hr 44 44 44 44 44 44 88 88 m3/h 26 26 26 26 26 26 52 52 Air flow ft3/min

Technical data

284

ACS550 Users Manual

Drive ACS550-x1-031A-4 -038A-4 -044A-4 -045A-4 -059A-4 -072A-4 -077A-4 -078A-4 -087A-4 -096A-4 -097A-4 -124A-4 -125A-4 -157A-4 -180A-4 -195A-4 -246A-4 Frame size R3 R3 R4 R3 R4 R4 R5 R4 R4 R5 R4 R6 R5 R6 R6 R6 R6 457 562 667 667 907 1120 1295 1295 1440 1440 1440 1940 1940 2310 2810 3050 3050 W

Heat loss BTU/hr 1561 1919 2278 2278 3098 3825 4423 4423 4918 4918 4918 6625 6625 7889 9597 10416 10416 134 134 280 134 280 280 250 280 280 250 280 405 350 405 405 405 405 m3/h

Air flow ft3/min 79 79 165 79 165 165 147 165 165 147 165 238 205 238 238 238 238
00467918.xls B

Technical data

ACS550 Users Manual

285

Air flow, 500600 V drives Bng sau y lit k tn tht nhit v lng khng kh cn thit cho bin tn 500600 V .
Drive ACS550-U1-02A7-6 -03A9-6 -06A1-6 -09A0-6 -011A-6 -017A-6 -022A-6 -027A-6 -032A-6 -041A-6 -052A-6 -062A-6 -077A-6 -099A-6 -125A-6 -144A-6 Frame size R2 R2 R2 R2 R2 R2 R3 R3 R4 R4 R4 R4 R6 R6 R6 R6 52 73 127 172 232 337 457 562 667 907 1117 1357 2310 2310 2310 2310 W 178 249 434 587 792 1151 1561 1919 2278 3098 3815 4634 7889 7889 7889 7889 Heat loss BTU/hr 88 88 88 88 88 88 134 134 280 280 280 280 405 405 405 405 m3/h 52 52 52 52 52 52 79 79 165 165 165 165 238 238 238 238
00467918.xls B

Air flow ft3/min

Technical data

286

ACS550 Users Manual

Dimensions and weights


Cc kch thc v khi lng cho ACS550 ty thuc kch thc khung v loi v . nu khng chc chn kch thc khung, u tin, tm loi m trn nhn bin tn (xem phn Type code trn trang 13 v Drive labels trn trang 12). Sau tm loi m trong bng phn loi (xem chng Technical data, trang 259), xc nh kch thc khung . mt b bng v chiu cho bin tn ACS550 nm trong ACS550 Technical Reference Manual. Mounting dimensions
W1 W2 See detail A

H1

See detail B

b Detail A

d Detail B
X0032

IP21 / UL type 1 and IP54 / UL type 12 Dimensions for each frame size Ref. W11 W21 H11 a b c d
1

R1 mm 98.0 -318 5.5 10.0 5.5 5.5 in 3.9 -12.5 0.2 0.4 0.2 0.2 mm 98.0 -418 5.5 10.0 5.5 5.5

R2 in 3.9 -16.4 0.2 0.4 0.2 0.2 mm 160 98.0 473 6.5 13.0 8.0 6.5

R3 in 6.3 3.9 18.6 0.25 0.5 0.3 0.25 mm 160 98.0 578 6.5 13.0 8.0 6.5

R4 in 6.3 3.9 22.8 0.25 0.5 0.3 0.25 mm 238 -588 6.5 14.0 8.5 6.5

R5 in 9.4 -23.2 0.25 0.55 0.3 0.25 mm 263 -675 9.0 14.0 8.5 9.0

R6 in 10.4 -26.6 0.35 0.55 0.3 0.35

Center to center dimension.

Technical data

ACS550 Users Manual

287

Outside dimensions Drives with IP21 / UL type 1 enclosures


D W

H2 H3

X0031

IP21 / UL type 1 dimensions for each frame size Ref. W H H2 H3 D R1 mm 125 330 315 369 212 in 4.9 13.0 12.4 14.5 8.3 mm 125 430 415 469 222 R2 in 4.9 16.9 16.3 18.5 8.7 mm 203 490 478 583 231 R3 in 8.0 19.3 18.8 23.0 9.1 mm 203 596 583 689 262 R4 in 8.0 23.5 23.0 27.1 10.3 mm 267 602 578 736 286 R5 in 10.5 23.7 22.8 29.1 11.3 mm 302 700 698 880 400 R6 in 11.9 27.6 27.5 34.7 15.8

00467918.xls B

Technical data

288

ACS550 Users Manual

Drives with IP54 / UL type 12 enclosures


W2

H3

D IP54 / UL type 12 Dimensions for each frame size

Ref.

R1 mm in 8.4 8.8 18.1 9.2

R2 mm 213 222 561 245 in 8.4 8.8 22.1 9.6

R3 mm 257 267 629 254 in 10.1 10.5 24.8 10.0

R4 mm 257 267 760 285 in 10.1 10.5 29.9 11.2

R5 mm 369 369 775 309 in 14.5 14.5 30.5 12.2

R6 mm 410 410 926 423 in 16.1 16.1 36.5 16.7

W W2 H3 D

213 222 461 234

00467918.xls B

Weight Bng sau y lit k trng lng ti a in hnh cho mi kch thc khung. Cc bin th trong mi kch thc khung (do cc thnh phn lin kt vi in p/dng in danh nh v ty chn) l nh hn.
Weight Enclosure kg IP21 / UL type 1 IP54 / UL type 12 6.5 8.0 R1 lb 14.3 17.6 kg 9.0 11.0 R2 lb 19.8 24.3 kg 16 17.0 R3 lb 35 37.5 kg 24 26.0 R4 lb 53 57.3 kg 34 42.0 R5 lb 75 92.6 kg 69 86.0 R6 lb 152 190

00467918.xls B

Technical data

ACS550 Users Manual

289

Degrees of protection
V my c sn: IP21 / UL loi v 1. cc v tr c lp cho bi v khng kh, khng kh c tnh n mn hoc cht lng, v cht gy nhim nh ngng t, bi v cc ht cacbon kim loi . IP54 / UL loi v 12 . loi v ny cung cp bo v khi bi trong khng kh v nh sng hoc nc phung vo t mi hng . So vi IP21 / UL loi v 1 , IP54 / UL loi v 12 c: mt v nha bn trong nh v IP21 . mt v nha bn ngoi khc . mt qut lm mt b sung bn trong ci thin lm mt . kch thc ln hn . nh mc tng t (khng yu cu gim ti ).

Ambient conditions
Bng sau y lit k cc yu cu mi trng ACS550.
Ambient environment requirements Installation site 01000 m (03 300 ft) Altitude 10002000 m (3 3006 600 ft) if PN and I2N derated 1% every 100 m above 1000 m (300 ft above 3 300 ft) Min. -15 C (5 F) no frost allowed -4070 C (-40158 F) Max. (fsw = 1 or 4) 40 C (104 F); 50 C (122 F) if PN and I2N derated to 90% Ambient temperature Max. (fsw = 8) 40 C (104 F) if PN and I2N derated to 80% Max. (fsw = 12) 30 C (86 F) if PN and I2N derated to 65% (to 50% for 600 V, R4 frame sizes, that is for ACS550-U1-032A-6 ACS550-U1062A-6) Relative humidity < 95% (non-condensing) No conductive dust allowed. The ACS550 should be installed in clean air according to enclosure classification. Cooling air must be clean, free from corrosive materials and free from electrically conductive dust. Chemical gases: Class 3C2 Solid particles: Class 3S2 Storage No conductive dust allowed. Chemical gases: Class 1C2 Solid particles: Class 1S2 Transportation No conductive dust allowed. Chemical gases: Class 2C2 Solid particles: Class 2S2 Storage and transportation in the protective package

Contamination levels (IEC 721-3-3)

Technical data

290

ACS550 Users Manual

Bng sau y lit k cc ng sut kim nh tiu chun ng dn ACS550.


Stress tests Without shipping package Mechanical conditions: In accordance with IEC 60721-3-3, Class 3M4 29 Hz 3.0 mm (0.12 in) 9200 Hz 10 m/s2 (33 ft/s2) Not allowed Not allowed In accordance with IEC 68-2-29: max. 100 m/s2 (330 ft/s2), 11ms Free fall 76 cm (30 in), frame size R1 61cm (24 in), frame size R2 46 cm (18 in), frame size R3 31 cm (12 in), frame size R4 25 cm (10 in), frame size R5 15 cm (6 in), frame size R6 Inside shipping package In accordance with ISTA 1A and 1B specifications.

Sinusoidal vibration

Shock

Materials
Material specifications PC/ABS 2.5 mm, color NCS 1502-Y or NCS 7000-N Hot-dip zinc coated steel sheet 1.52 mm, thickness of coating 20 micrometers. If the surface is painted, the total thickness of the coating (zinc and paint) is 80100 micrometers. Cast aluminium AlSi Extruded aluminium AlSi Package Corrugated board, expanded polystyrene, plywood, raw wood (heat dried). Package wrap consists of one or more of the following: PE-LD plastic wrap, PP or steel bands. The drive contains raw materials that should be recycled to preserve energy and natural resources. The package materials are environmentally compatible and recyclable. All metal parts can be recycled. The plastic parts can either be recycled or burned under controlled circumstances, according to local regulations. Most recyclable parts are marked with recycling marks. Disposal If recycling is not feasible, all parts excluding electrolytic capacitors and printed circuit boards can be landfilled. The DC capacitors contain electrolyte and, if the drive is not provided with the RoHS marking, the printed circuit boards contain lead, both of which will be classified as hazardous waste within the EU. They must be removed and handled according to local regulations. For further information on environmental aspects and more detailed recycling instructions, please contact your local ABB distributor.

Drive enclosure

Technical data

ACS550 Users Manual

291

Applicable standards
Drive compliance with the following standards is identified by the standard marks on the type code label.
Mark EN 50178 (1997) IEC/EN 60204-1 (2005) Applicable standards Electronic equipment for use in power installations Safety of machinery. Electrical equipment of machines. Part 1: General requirements. Provisions for compliance: The final assembler of the machine is responsible for installing: an emergency-stop device a supply disconnecting device. IEC/EN 60529 (2004) IEC 60664-1 (2002) Degrees of protection provided by enclosures (IP code)

Insulation coordination for equipment within low-voltage


systems. Part 1: Principles, requirements and tests

IEC/EN 61800-5-1 (2003) Adjustable speed electrical power drive systems. Part 5-1: Safety requirements. Electrical, thermal and energy IEC/EN 61800-3 (2004) IEC/EN 61800-3 (2004) Adjustable speed electrical power drive systems. Part 3: EMC requirements and specific test methods Adjustable speed electrical power drive systems. Part 3: EMC requirements and specific test methods UL Standard for Safety, Power Conversion Equipment, third edition CSA Standard for Industrial Control Equipment (for ACS550-U1 drives only)

UL 508C

C22.2 No. 14

CE marking
A CE mark is attached to the drive to verify that the drive follows the provisions of the European Low Voltage and EMC Directives (Directive 73/23/EEC, as amended by 93/68/EEC, and Directive 89/336/EEC, as amended by 93/68/EEC). Note: The 600 V ACS550-U1 drives are not CE approved. Compliance with the EMC Directive The Directive defines the requirements for immunity and emissions of electrical equipment used within the European Union. The EMC product standard [IEC/EN 61800-3 (2004)] covers requirements stated for drives. Compliance with IEC/EN 61800-3 (2004) See page 293.

C-Tick marking
The drive carries C-Tick marking. C-Tick marking is required in Australia and New Zealand. A C-Tick mark is attached to the drive to verify compliance with the relevant standard (IEC 61800-3 (2004)

Technical data

292

ACS550 Users Manual

Adjustable speed electrical power drive systems Part 3: EMC product standard including specific test methods), mandated by the Trans-Tasman Electromagnetic Compatibility Scheme. The Trans-Tasman Electromagnetic Compatibility Scheme (EMCS) was introduced by the Australian Communication Authority (ACA) and the Radio Spectrum Management Group (RSM) of the New Zealand Ministry of Economic Development (NZMED) in November 2001. The aim of the scheme is to protect the radio frequency spectrum by introducing technical limits for emission from electrical/ electronic products. Compliance with IEC/EN 61800-3 (2004) See page 293.

UL/CSA markings
An UL mark is attached to ACS550 drives to verify that the drive follows the provisions of UL 508C. A CSA mark is attached to ACS550-U1 type drives to verify that the drive follows the provisions of C22.2 NO. 14. The ACS550 is suitable for use on a circuit capable of delivering not more than 100,000 RMS symmetrical amperes, 480 V maximum. Branch circuit protection must be provided in accordance with local codes. The ACS550 has an electronic motor protection feature that complies with the requirements of UL 508C and, for ACS550-U1, C22.2 No. 14. When this feature is selected and properly adjusted, additional overload protection is not required unless more than one motor is connected to the drive or unless additional protection is required by applicable safety regulations. See parameters 3005 (MOT THERM PROT) and 3006 (MOT THERM RATE). The drives are to be used in a controlled environment. See section Ambient conditions on page 289 for specific limits. Note: For open type enclosures, i.e. drives without the conduit box and/or cover for IP21 / UL type 1 drives, or without the conduit plate and/or hood for IP54 / UL type 12 drives, the drive must be mounted inside an enclosure in accordance with National Electric Code and local electrical codes. Brake choppers, when applied with appropriately sized brake resistors, will allow the drive to dissipate regenerative energy (normally associated with quickly decelerating a motor). Frame sizes R1 and R2 have a built-in brake chopper as standard equipment. For frame sizes R3R6, contact your ABB representative for appropriate parts. See section Brake components on page 277.

IEC/EN 61800-3 (2004) Definitions


EMC stands for Electromagnetic Compatibility. It is the ability of electrical/electronic equipment to operate without problems within an electromagnetic environment.

Technical data

ACS550 Users Manual

293

Likewise, the equipment must not disturb or interfere with any other product or system within its locality. First environment includes establishments connected to a low-voltage network which supplies buildings used for domestic purposes. Second environment includes establishments connected to a network not directly supplying domestic premises. Drive of category C2: drive of rated voltage less than 1000 V and intended to be installed and commissioned only by a professional when used in the first environment. Note: A professional is a person or organisation having necessary skills in installing and/or commissioning power drive systems, including their EMC aspects. Category C2 has the same EMC emission limits as the earlier class first environment restricted distribution. EMC standard IEC/EN 61800-3 does not any more restrict the distribution of the drive, but the using, installation and commissioning are defined. Drive of category C3: drive of rated voltage less than 1000 V, intended for use in the second environment and not intended for use in the first environment. Category C3 has the same EMC emission limits as the earlier class second environment unrestricted distribution.

Compliance with the IEC/EN 61800-3 (2004)


The immunity performance of the drive complies with the demands of IEC/ EN 61800-3, category C2 (see page 292 for IEC/EN 61800-3 definitions). The emission limits of IEC/EN 61800-3 are complied with the provisions described below. First environment (drives of category C2) 1. The internal EMC filter is connected. 2. The motor and control cables are selected as specified in this manual. 3. The drive is installed according to the instructions given in this manual. 4. The motor cable length does not exceed the allowed maximum length specified in section Motor cable length for 400 V drives on page 272 for the frame size and switching frequency in use. WARNING! In a domestic environment, this product may cause radio inference, in which case supplementary mitigation measures may be required. Second environment (drives of category C3) 1. The internal EMC filter is connected. 2. The motor and control cables are selected as specified in this manual. 3. The drive is installed according to the instructions given in this manual. 4. The motor cable length does not exceed the allowed maximum length specified in section Motor cable length for 400 V drives on page 272 for the frame size and switching frequency in use.

Technical data

294

ACS550 Users Manual

WARNING! A drive of category C3 is not intended to be used on a low-voltage public network which supplies domestic premises. Radio frequency interference is expected if the drive is used on such a network.

Note: It is not allowed to install a drive with the internal EMC filter connected on IT (ungrounded) systems. The supply network becomes connected to ground potential through the EMC filter capacitors, which may cause danger or damage the drive. Note: It is not allowed to install a drive with the internal EMC filter connected to a corner grounded TN system as this would damage the drive.

Liability limits
The manufacturer is not responsible for: Any costs resulting from a failure if the installation, commissioning, repair, alteration, or ambient conditions of the drive do not fulfil the requirements specified in the documentation delivered with the unit and other relevant documentation. Units subjected to misuse, negligence or accident. Units comprised of materials provided or designs stipulated by the purchaser. In no event shall the manufacturer, its suppliers or subcontractors be liable for special, indirect, incidental or consequential damages, losses or penalties. This is the sole and exclusive warranty given by the manufacturer with respect to the equipment and is in lieu of and excludes all other warranties, express or implied, arising by operation of law or otherwise, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. If you have any questions concerning your ABB drive, please contact the local distributor or ABB office. The technical data, information and specifications are valid at the time of printing. The manufacturer reserves the right to make modifications without prior notice.

Technical data

ACS550 Users Manual

295

Product protection in the USA


This product is protected by one or more of the following US patents: 4,920,306 5,612,604 6,094,364 6,252,436 6,370,049 6,741,059 6,940,253 6,977,449 7,034,510 7,082,374 D510,320 5,301,085 5,654,624 6,147,887 6,265,724 6,396,236 6,774,758 6,934,169 6,984,958 7,036,223 7,084,604 D511,137 5,463,302 5,799,805 6,175,256 6,305,464 6,448,735 6,844,794 6,956,352 6,985,371 7,045,987 7,098,623 D511,150 5,521,483 5,940,286 6,184,740 6,313,599 6,498,452 6,856,502 6,958,923 6,992,908 7,057,908 7,102,325 D512,026 5,532,568 5,942,874 6,195,274 6,316,896 6,552,510 6,859,374 6,967,453 6,999,329 7,059,390 D503,931 D512,696 5,589,754 5,952,613 6,229,356 6,335,607 6,597,148 6,922,883 6,972,976 7,023,160 7,067,997 D510,319 D521,466

Other patents pending.

Technical data

296

ACS550 Users Manual

Technical data

ACS550 Users Manual

297

Index

Numerics
0xxxx register EFB function codes . . . . . . . . . . . . . . . . . . . 204 EFB mapping . . . . . . . . . . . . . . . . . . . . . . . 202 1xxxx register EFB function codes . . . . . . . . . . . . . . . . . . . 205 EFB mapping . . . . . . . . . . . . . . . . . . . . . . . 204 2-wire sensor, connection example . . . . . . . . . . . 80 3-wire macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 3xxxx register EFB function codes . . . . . . . . . . . . . . . . . . . 205 EFB mapping . . . . . . . . . . . . . . . . . . . . . . . 205 4xxxx register EFB function codes . . . . . . . . . . . . . . . . . . . 207 EFB mapping . . . . . . . . . . . . . . . . . . . . . . . 205

A
ABB feedback on ABB manuals . . . . . . . . . . . . . 309 product and service inquiries . . . . . . . . . . . 309 product training . . . . . . . . . . . . . . . . . . . . . . 309 standard (default) macro . . . . . . . . . . . . . . . . 72 acceleration /deceleration, parameter group . . . . . . . . . . 131 at aux. stop (PFC), parameter. . . . . . . . . . . 186 compensation, parameter . . . . . . . . . . . . . . 134 ramp select, parameter . . . . . . . . . . . . . . . . 131 ramp shape, parameter. . . . . . . . . . . . . . . . 131 ramp time (PFC), parameter . . . . . . . . . . . . 186 ramp zero select, parameter . . . . . . . . . . . . 132 time, parameter . . . . . . . . . . . . . . . . . . . . . . 131 activate (external PID), parameter. . . . . . . . . . . 168 actual input (PID), parameters. . . . . . . . . . . . . . 164 actual max. (PID), parameters. . . . . . . . . . . . . . 164 actual min. (PID), parameters . . . . . . . . . . . . . . 164 actual values mapping, FBA, generic profile. . . . . . . . . . . 241 scaling, EFB comm . . . . . . . . . . . . . . . . . . . 197 scaling, FBA comm . . . . . . . . . . . . . . . . . . . 228 scaling, FBA, ABB drives profile . . . . . . . . . 239 scaling, FBA, generic profile . . . . . . . . . . . . 241 alarm codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 codes (Basic Control Panel) . . . . . . . . . . . . 253 display enable, parameter. . . . . . . . . . . . . . 124 listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 words, data parameters . . . . . . . . . . . . . . . 105 alternate macro . . . . . . . . . . . . . . . . . . . . . . . . . . 74 altitude derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 environment limit . . . . . . . . . . . . . . . . . . . . . 289 shipping limit . . . . . . . . . . . . . . . . . . . . . . . . 289 ambient conditions. . . . . . . . . . . . . . . . . . . . . . . 289

ambient temperature derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 environment limit . . . . . . . . . . . . . . . . . . . . . 289 shipping limit. . . . . . . . . . . . . . . . . . . . . . . . . 289 analog cable, requirements. . . . . . . . . . . . . . . . . 282 analog I/O connections . . . . . . . . . . . . . . . . . . . . . . . . . . 22 specifications . . . . . . . . . . . . . . . . . . . . . . . . . 22 analog input parameter group. . . . . . . . . . . . . . . . . . . . . . 115 data parameter . . . . . . . . . . . . . . . . . . . . . . . 101 fault limit, parameters . . . . . . . . . . . . . . . . . . 142 filter, parameters . . . . . . . . . . . . . . . . . . . . . 115 less than min. auto. reset, parameter. . . . . . 143 less than min., fault parameter . . . . . . . . . . . 140 loss, fault codes . . . . . . . . . . . . . . . . . . . . . . 245 maximum, parameters . . . . . . . . . . . . . . . . . 115 minimum, parameters. . . . . . . . . . . . . . . . . . 115 analog output parameter group. . . . . . . . . . . . . . . . . . . . . . 119 content max., parameters. . . . . . . . . . . . . . . 119 content min., parameters . . . . . . . . . . . . . . . 119 current max., parameters . . . . . . . . . . . . . . . 119 current min., parameters . . . . . . . . . . . . . . . 119 data content, parameters . . . . . . . . . . . . . . . 119 data parameters . . . . . . . . . . . . . . . . . . . . . . 101 filter, parameters . . . . . . . . . . . . . . . . . . . . . 119 angle mechanical, data parameter . . . . . . . . . . . . . 102 application block output, data parameter . . . . . . 100 application macro, parameter . . . . . . . . . . . . . . . . 98 application macros see macros arrow (Assistant Control Panel) . . . . . . . . . . . . . . 43 assistant (Assistant Control Panel) start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Assistant Control Panel see control panel (Assistant) assistants mode (Assistant Control Panel) . . . . . . 51 autochange interval, parameter . . . . . . . . . . . . . . . . . . . . 179 level, parameter . . . . . . . . . . . . . . . . . . . . . . 180 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 starting order counter . . . . . . . . . . . . . . . . . . 180 automatic reset see reset, automatic auxiliary motor see motor, auxiliary

B
backing up parameters Assistant Control Panel . . . . . . . . . . . . . . . . . 58 Basic Control Panel . . . . . . . . . . . . . . . . . . . . 69 Basic Control Panel see control panel (Basic)

Index

298

ACS550 Users Manual

battery (Assistant Control Panel). . . . . . . . . . . . baud rate (RS-232), parameter . . . . . . . . . . . . . braking components . . . . . . . . . . . . . . . . . . . . . . . . protection from overheated resistor . . . . . . resistor heat dissipation . . . . . . . . . . . . . . . selecting brake choppers/resistors . . . . . . . wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . break point frequency, fault parameter . . . . . . . buffer overruns (count), parameter . . . . . . . . . .

258 172 277 280 280 277 280 141 172

C
cable requirements control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 grounding . . . . . . . . . . . . . . . . . . . . . . . . . . 266 input power . . . . . . . . . . . . . . . . . . . . . . . . . 265 motor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 capacitor reforming. . . . . . . . . . . . . . . . . . . . . . . . . . . 258 replacement . . . . . . . . . . . . . . . . . . . . . . . . 258 category (IEC/EN 61800-3 definition) C2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 C3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 CB see control board CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 changed parameters (Assistant Control Panel). . 54 chopper see braking clock setting (Assistant Control Panel) . . . . . . . . 56 communication see EFB (embedded fieldbus) see EFB, drive parameters see FBA (fieldbus adapter) see FBA, drive parameters conduit kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 config file CPI firmware revision, parameter . . . . . . . . 171 fault code . . . . . . . . . . . . . . . . . . . . . . . . . . 247 id revision, parameter . . . . . . . . . . . . . . . . . 171 revision, parameter . . . . . . . . . . . . . . . . . . . 171 connections control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 EFB comm . . . . . . . . . . . . . . . . . . . . . . . . . 190 FBA module . . . . . . . . . . . . . . . . . . . . . . . . 224 X1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 constant speed see speed, constant construction code . . . . . . . . . . . . . . . . . . . . . . . . 13 contamination levels environment limit. . . . . . . . . . . . . . . . . . . . . 289 shipping limit . . . . . . . . . . . . . . . . . . . . . . . . 289 contrast, control panel (Assistant) . . . . . . . . . . . . 48 control connection specifications . . . . . . . . . . . . . . 281 location, data parameter . . . . . . . . . . . . . . . 100 terminal specifications. . . . . . . . . . . . . . . . . 282 through I/O interface . . . . . . . . . . . . . . . . . . . 38

control board overtemperature, fault code . . . . . . . . . . . . . 247 overtemperature, fault parameter. . . . . . . . . 142 temperature, data parameter . . . . . . . . . . . . 102 control cable connections . . . . . . . . . . . . . . . . . . . . . . . . . . 22 requirements . . . . . . . . . . . . . . . . . . . . . . . . 281 control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 cable requirements. . . . . . . . . . . . . . . . . . . . 282 comm error, fault parameter. . . . . . . . . . . . . 140 display bar-graph . . . . . . . . . . . . . . . . . 147, 148 display decimal point (form), parameters . . . 147 display max., parameters . . . . . . . . . . . . . . . 148 display min., parameters . . . . . . . . . . . . . . . 148 display process variables, parameter group 147 display selection, parameters. . . . . . . . . . . . 147 display units, parameters . . . . . . . . . . . . . . . 148 maintenance. . . . . . . . . . . . . . . . . . . . . . . . . 258 manual compatibility. . . . . . . . . . . . . . . . . . . . 41 parameter lock, parameter . . . . . . . . . . . . . . 121 pass code, parameter . . . . . . . . . . . . . . . . . 121 reference control, parameter . . . . . . . . . . . . 109 signal max., parameters. . . . . . . . . . . . . . . . 147 signal min., parameters . . . . . . . . . . . . . . . . 147 control panel (Assistant) . . . . . . . . . . . . . . . . . . . . 42 arrow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 assistants mode . . . . . . . . . . . . . . . . . . . . . . . 51 battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 changed parameters mode . . . . . . . . . . . . . . 54 clock set mode . . . . . . . . . . . . . . . . . . . . . . . . 56 direction of rotation. . . . . . . . . . . . . . . . . . 43, 47 display contrast . . . . . . . . . . . . . . . . . . . . . . . 48 fault logger mode . . . . . . . . . . . . . . . . . . . . . . 55 fault mode . . . . . . . . . . . . . . . . . . . 43, 243, 244 help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 how to do common tasks . . . . . . . . . . . . . . . . 44 I/O settings mode . . . . . . . . . . . . . . . . . . . . . . 61 main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 output mode . . . . . . . . . . . . . . . . . . . . . . . . . . 47 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 parameter backup mode . . . . . . . . . . . . . . . . 58 parameters mode . . . . . . . . . . . . . . . . . . . . . . 49 soft keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 start/stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 status line (LOC/REM, arrow) . . . . . . . . . . . . 43 control panel (Basic) . . . . . . . . . . . . . . . . . . . . . . . 62 alarm codes . . . . . . . . . . . . . . . . . . . . . . . . . 253 copy mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 direction of rotation. . . . . . . . . . . . . . . . . . 62, 64 fault mode . . . . . . . . . . . . . . . . . . . 63, 243, 244 how to do common tasks . . . . . . . . . . . . . . . . 63 main menu . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 output mode . . . . . . . . . . . . . . . . . . . . . . . . . . 65 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 parameter mode. . . . . . . . . . . . . . . . . . . . . . . 67 reference mode . . . . . . . . . . . . . . . . . . . . . . . 66 start/stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 control word ABB drives, FBA, description . . . . . . . . . . . . 232 EFB, description. . . . . . . . . . . . . . . . . . . . . . 209 FBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 FBA generic profile. . . . . . . . . . . . . . . . . . . . 240

Index

ACS550 Users Manual

299

cooling air flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 fan maintenance triggers. . . . . . . . . . . . . . . 139 heat loss . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 space requirement . . . . . . . . . . . . . . . . . . . 283 copy mode (Basic Control Panel) . . . . . . . . . . . . 69 corner grounded TN system . . . . . . . . . . . . . . . 267 warning about filters . . . . . . . . . . . . . . . . . . . . 6 warning about screws at EM1, EM3 . . . . . . . 20 warning about screws at F1, F2 . . . . . . . . . . 21 correction source (PID), parameter . . . . . . . . . . 169 cover remove . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 replace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 cover, top, see hood CRC errors (count), parameter . . . . . . . . . . . . . 172 crimp-on ring lugs . . . . . . . . . . . . . . . . . . . . . . . 269 critical speeds (avoiding) parameter group . . . . . . . . . . . . . . . . . . . . . 136 high, parameters . . . . . . . . . . . . . . . . . . . . . 136 low, parameters. . . . . . . . . . . . . . . . . . . . . . 136 select, parameter . . . . . . . . . . . . . . . . . . . . 136 C-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . 291 current at fault, history parameter . . . . . . . . . . . . . . 106 data parameter . . . . . . . . . . . . . . . . . . . . . . 100 max. limit, parameter. . . . . . . . . . . . . . . . . . 125 measurement, fault code. . . . . . . . . . . . . . . 246 rating code . . . . . . . . . . . . . . . . . . . . . . . . . . 13

D
DC brake time, parameter . . . . . . . . . . . . . . . . . 129 bus voltage, data parameter . . . . . . . . . . . . 100 current ref., parameter . . . . . . . . . . . . . . . . 129 magnetizing time, parameter. . . . . . . . . . . . 128 overvoltage, fault code . . . . . . . . . . . . . . . . 245 undervoltage, fault code . . . . . . . . . . . . . . . 245 voltage stabilizer, parameter . . . . . . . . . . . . 138 deceleration parameter group . . . . . . . . . . . . . . . . . . . . . 131 at aux. start (PFC), parameter . . . . . . . . . . 186 emergency time, parameter . . . . . . . . . . . . 132 ramp select, parameter . . . . . . . . . . . . . . . . 131 ramp shape, parameter. . . . . . . . . . . . . . . . 131 ramp time (PFC), parameter . . . . . . . . . . . . 186 ramp zero select, parameter . . . . . . . . . . . . 132 time, parameter . . . . . . . . . . . . . . . . . . . . . . 131 default values listing for macros . . . . . . . . . . . . . . . . . . . . . . 82 listing for parameters. . . . . . . . . . . . . . . . . . . 85 derating adjustment example . . . . . . . . . . . . . . . . . . 262 altitude. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 single phase supply. . . . . . . . . . . . . . . . . . . 262 switching frequency. . . . . . . . . . . . . . . . . . . 262 temperature. . . . . . . . . . . . . . . . . . . . . . . . . 262 derivation time (PID), parameter . . . . . . . . . . . . 161 derivation time, parameter. . . . . . . . . . . . . . . . . 133 device overtemperature, fault code . . . . . . . . . . 245

diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 EFB comm . . . . . . . . . . . . . . . . . . . . . . . . . . 198 FBA comm . . . . . . . . . . . . . . . . . . . . . . . . . . 229 digital cable requirements . . . . . . . . . . . . . . . . . . 282 digital input at fault, history parameters . . . . . . . . . . . . . . 106 connections . . . . . . . . . . . . . . . . . . . . . . . . . . 22 specifications . . . . . . . . . . . . . . . . . . . . . . . . . 23 status, data parameter . . . . . . . . . . . . . . . . . 101 digital output connections . . . . . . . . . . . . . . . . . . . . . . . . . . 22 specifications . . . . . . . . . . . . . . . . . . . . . . . . 281 dimensions drive, mounting. . . . . . . . . . . . . . . . . . . . . . . 286 drive, outside . . . . . . . . . . . . . . . . . . . . . . . . 287 DIP switches . . . . . . . . . . . . . . . . . . . . . . . . . . 20, 22 direction control, parameter . . . . . . . . . . . . . . . . 108 direction of rotation Assistant Control Panel . . . . . . . . . . . . . . 43, 47 Basic Control Panel . . . . . . . . . . . . . . . . . 62, 64 display format (PID), parameter . . . . . . . . . . . . . 161 disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 download parameter sets application . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 full set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 user sets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 drive EFB comm installation . . . . . . . . . . . . . . . . . 190 FBA module installation . . . . . . . . . . . . . . . . 224 id, fault code . . . . . . . . . . . . . . . . . . . . . . . . . 247 mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 mounting dimensions . . . . . . . . . . . . . . . . . . 286 outside dimensions. . . . . . . . . . . . . . . . . . . . 287 rating, parameter . . . . . . . . . . . . . . . . . . . . . 146 temperature, data parameter . . . . . . . . . . . . 100 weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 drive on time, data parameters . . . . . . . . . . . . . . 102

E
earth fault fault code . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 earthing see ground

Index

300

ACS550 Users Manual

EFB (embedded fieldbus) . . . . . . . . . . . . . . . . . 189 actual value scaling . . . . . . . . . . . . . . . . . . 197 actual values . . . . . . . . . . . . . . . . . . . . . . . . 197 analog output control, activate . . . . . . . . . . 195 comm fault response . . . . . . . . . . . . . . . . . 196 configuration . . . . . . . . . . . . . . . . . . . . . . . . 192 configure for loss of communication . . . . . . 199 control interface . . . . . . . . . . . . . . . . . . . . . 189 control word . . . . . . . . . . . . . . . . . . . . . . . . 209 diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . 198 drive control of functions, activate. . . . . . . . 193 exception codes . . . . . . . . . . . . . . . . . . . . . 208 fault code 28 . . . . . . . . . . . . . . . . . . . . . . . . 200 fault code 31 . . . . . . . . . . . . . . . . . . . . . . . . 200 fault code 32 . . . . . . . . . . . . . . . . . . . . . . . . 200 fault code 33 . . . . . . . . . . . . . . . . . . . . . . . . 200 fault tracing parameters . . . . . . . . . . . . . . . 198 fault, duplicate stations . . . . . . . . . . . . . . . . 199 fault, intermittent off-line . . . . . . . . . . . . . . . 200 fault, no master station on line . . . . . . . . . . 199 fault, swapped wires . . . . . . . . . . . . . . . . . . 199 feedback from drive . . . . . . . . . . . . . . . . . . 197 input reference sel., activate . . . . . . . . . . . . 194 installation . . . . . . . . . . . . . . . . . . . . . . . . . . 190 misc. drive control, activate. . . . . . . . . . . . . 194 modbus actual values . . . . . . . . . . . . . . . . . 208 PID control setpoint source, activate . . . . . 196 planning . . . . . . . . . . . . . . . . . . . . . . . . . . . 190 profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 reference scaling, ABB drives profile . . . . . 218 relay output control, activate . . . . . . . . . . . . 195 set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 start/stop/direction control, activate . . . . . . 193 state diagram . . . . . . . . . . . . . . . . . . . . . . . 217 status word . . . . . . . . . . . . . . . . . . . . . . . . . 212 termination . . . . . . . . . . . . . . . . . . . . . . . . . 191 EFB, drive parameters . . . . . . . . . . . . . . . . . . . 173 protocol, parameter group . . . . . . . . . . . . . 173 baud rate, parameter . . . . . . . . . . . . . . . . . 173 command words, data parameters . . . . . . . 104 config file, fault code . . . . . . . . . . . . . . . . . . 247 control profile, parameter . . . . . . . . . . . . . . 173 CRC errors (count), parameter . . . . . . . . . . 173 fault codes . . . . . . . . . . . . . . . . . . . . . . . . . 247 fault function, parameter . . . . . . . . . . . . . . . 142 fault time, parameter . . . . . . . . . . . . . . . . . . 142 ok messages (count), parameter . . . . . . . . 173 parameters . . . . . . . . . . . . . . . . . . . . . 173, 174 parity, parameter. . . . . . . . . . . . . . . . . . . . . 173 protocol id, parameter . . . . . . . . . . . . . . . . . 173 protocol select, parameter . . . . . . . . . . . . . 187 relay output word, data parameter . . . . . . . 101 station id, parameter . . . . . . . . . . . . . . . . . . 173 status words, data parameters . . . . . . . . . . 104 status, parameter . . . . . . . . . . . . . . . . . . . . 173 UART errors (count), parameter . . . . . . . . . 173 values, data parameter . . . . . . . . . . . . . . . . 101 efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 ELV (Extra Low Voltage) . . . . . . . . . . . . . . . . . . . 23 EM1 and EM3 screws location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 on corner grounded TN system . . . . . . . . . 267 on IT systems . . . . . . . . . . . . . . . . . . . . . . . 268 warning . . . . . . . . . . . . . . . . . . . . . 20, 267, 268

embedded fieldbus see EFB see EFB, drive parameters EMC CE marking . . . . . . . . . . . . . . . . . . . . . . . . . 291 C-Tick marking . . . . . . . . . . . . . . . . . . . . . . . 291 motor cable requirements . . . . . . . . . . . . . . 274 emergency deceleration time, parameter . . . . . . . . . . . . 132 stop devices . . . . . . . . . . . . . . . . . . . . . . . . . 265 stop select, parameter . . . . . . . . . . . . . . . . . 129 enclosure protection class code . . . . . . . . . . . . . . . . . . . 13 types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 encoder parameter group. . . . . . . . . . . . . . . . . . . . . . 170 enable, parameter . . . . . . . . . . . . . . . . . . . . 170 error, fault code . . . . . . . . . . . . . . . . . . . . . . 246 fault, parameter . . . . . . . . . . . . . . . . . . . . . . 170 number of pulses, parameter . . . . . . . . . . . . 170 position reset enable, parameter . . . . . . . . . 170 zero pulse detected, data parameter . . . . . . 102 zero pulse enable, parameter . . . . . . . . . . . 170 energy intake in kWh, data parameter . . . . . . . . . . . 103 intake in MWh, data parameter . . . . . . . . . . 103 error value inversion (PID), parameter . . . . . . . . 161 exception codes, EFB modbus . . . . . . . . . . . . . . 208 external comm module, parameter group see FBA, drive parameters external commands selection, parameter. . . . . . 107 external control selection, parameter . . . . . . . . . 109 external fault automatic reset, parameter . . . . . . . . . . . . . 143 fault codes . . . . . . . . . . . . . . . . . . . . . . . . . . 246 parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 140 external reference, data parameter . . . . . . . . . . 100

F
F1 and F2 screws location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 on corner grounded TN system . . . . . . . . . . 267 on IT systems. . . . . . . . . . . . . . . . . . . . . . . . 268 warning. . . . . . . . . . . . . . . . . . . . . . 21, 267, 268 fan maintenance . . . . . . . . . . . . . . . . . . . . . 256, 257

Index

ACS550 Users Manual

301

fault

functions, parameter group . . . . . . . . . . . . . 140 history, parameter group . . . . . . . . . . . . . . . 106 codes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 comm failure (EFB) . . . . . . . . . . . . . . . . . . . 196 current at, history parameter . . . . . . . . . . . . 106 digital input status at, history parameter . . . 106 FBA comm . . . . . . . . . . . . . . . . . . . . . . . . . 228 frequency at, history parameter . . . . . . . . . 106 history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 last, history parameter. . . . . . . . . . . . . . . . . 106 listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 logging (Assistant Control Panel) . . . . . . . . . 55 mode (Assistant Control Panel) . . 43, 243, 244 mode (Basic Control Panel) . . . . . 63, 243, 244 previous, history parameter. . . . . . . . . . . . . 106 reset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249 reset select, parameter . . . . . . . . . . . . . . . . 121 speed at, history parameter . . . . . . . . . . . . 106 status at, history parameter. . . . . . . . . . . . . 106 time of, history parameters . . . . . . . . . . . . . 106 torque at, history parameter . . . . . . . . . . . . 106 voltage at, history parameter. . . . . . . . . . . . 106 words, data parameters . . . . . . . . . . . . . . . 105 fault display alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 fault names . . . . . . . . . . . . . . . . . . . . . . . . . 244 FB actual signals, parameter group. . . . . . . . . . 104 FBA protocol listing . . . . . . . . . . . . . . . . . . . . . . . 221 FBA (fieldbus adapter). . . . . . . . . . . . . . . . . . . . 221 actual values . . . . . . . . . . . . . . . . . . . . . . . . 223 analog output control, activate . . . . . . . . . . 227 comm fault response. . . . . . . . . . . . . . . . . . 228 configuration . . . . . . . . . . . . . . . . . . . . . . . . 225 control word. . . . . . . . . . . . . . . . . . . . . . . . . 222 control word, ABB drives. . . . . . . . . . . . . . . 232 diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . 229 drive feedback. . . . . . . . . . . . . . . . . . . . . . . 228 fieldbus control, activate . . . . . . . . . . . . . . . 225 input reference sel., activate . . . . . . . . . . . . 226 installation . . . . . . . . . . . . . . . . . . . . . . . . . . 224 PID control setpoint source, activate. . . . . . 228 planning. . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 reference . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 relay output control, activate . . . . . . . . . . . . 227 set-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 start/stop /direction control, activate . . . . . . 225 state diagram, ABB drives. . . . . . . . . . . . . . 235 status word . . . . . . . . . . . . . . . . . . . . . . . . . 223 status word, ABB drives . . . . . . . . . . . . . . . 233

FBA, drive parameters . . . . . . . . . . . . . . . . . . . . 171 ext comm module parameter group . . . . . . . 171 command words, data parameters. . . . . . . . 104 config file CPI firmware revision, parameter. 171 config file id revision, parameter. . . . . . . . . . 171 config file revision, parameter . . . . . . . . . . . 171 fault function, parameter. . . . . . . . . . . . . . . . 142 fault time, parameter . . . . . . . . . . . . . . . . . . 142 fieldbus appl. program revision, parameter . 171 fieldbus CPI firmware revision, parameter . . 171 fieldbus parameter refresh, parameter . . . . . 171 fieldbus parameters . . . . . . . . . . . . . . . . . . . 171 fieldbus status, parameter . . . . . . . . . . . . . . 171 fieldbus type, parameter. . . . . . . . . . . . . . . . 171 protocol select, parameter . . . . . . . . . . . . . . 187 relay output word, data parameter . . . . . . . . 101 status words, data parameters . . . . . . . . . . . 104 values, data parameter. . . . . . . . . . . . . . . . . 101 feedback multiplier (PID), parameter . . . . . . . . . . . . . . 163 on ABB manuals. . . . . . . . . . . . . . . . . . . . . . 309 select (PID), parameter . . . . . . . . . . . . . . . . 163 field weakening point . . . . . . . . . . . . . . . . . . . . . 271 fieldbus see EFB (embedded fieldbus) see EFB, drive parameters see FBA (fieldbus adapter) see FBA, drive parameters fieldbus adapter see FBA see FBA, drive parameters fieldbus, embedded see EFB see EFB, drive parameters firmware panel, version . . . . . . . . . . . . . . . . . . . . . . 41, 45 version, parameter . . . . . . . . . . . . . . . . . 60, 146 first environment (C2), compliance with IEC/EN 61800-3 . . . . 293 (C2), motor cable length. . . . . . . . . . . . . . . . 272 definition . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 FlashDrop application macro, parameter. . . . . . . . . . . . . 98 connection . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 parameter view, parameter . . . . . . . . . . . . . 124 floating network see IT system flux braking, parameter . . . . . . . . . . . . . . . . . . . . 137 flux optimization, parameter . . . . . . . . . . . . . . . . 137 force trip, fault code . . . . . . . . . . . . . . . . . . . . . . 247 frame errors (count), parameter . . . . . . . . . . . . . 172 frame size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 free fall, stress testing . . . . . . . . . . . . . . . . . . . . . 290 frequency at fault, history parameter. . . . . . . . . . . . . . . 106 max. limit, parameter . . . . . . . . . . . . . . . . . . 126 min. limit, parameter . . . . . . . . . . . . . . . . . . . 126 motor, resolution. . . . . . . . . . . . . . . . . . . . . . 271 motor, specification . . . . . . . . . . . . . . . . . . . 271 switching, parameter . . . . . . . . . . . . . . . . . . 138

Index

302

ACS550 Users Manual

fuses 208240 V drives . . . . . . . . . . . . . . . . . . . 264 380480 V drives . . . . . . . . . . . . . . . . . . . 264 500600 V drives . . . . . . . . . . . . . . . . . . . 265

G
gain (PID), parameter . . . . . . . . . . . . . . . . . . . . 160 generic profile, FBA actual value mapping . . . . . . . . . . . . . . . . . 241 actual value scaling . . . . . . . . . . . . . . . . . . 241 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 reference scaling . . . . . . . . . . . . . . . . . . . . 240 technical data . . . . . . . . . . . . . . . . . . . . . . . 240 gland kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 ground cable/wire requirements . . . . . . . . . . . . . . . 266 fault protection . . . . . . . . . . . . . . . . . . . . . . 273

integration time (PID), parameter . . . . . . . . . . . . 161 integration time, parameter. . . . . . . . . . . . . . . . . 133 interlocks, parameter . . . . . . . . . . . . . . . . . . . . . 181 internal setpoint (PID), parameter . . . . . . . . . . . 163 IR compensation frequency, parameter . . . . . . . . . . . . . . . . . . 137 parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 137 voltage, parameter . . . . . . . . . . . . . . . . . . . . 137 isolation, between AC power source and drive . 263 IT system connections . . . . . . . . . . . . . . . . . . . . . . . . . 268 warning about filters . . . . . . . . . . . . . . . . . 6, 276 warning about screws at EM1, EM3. . . . . . . . 20 warning about screws at F1, F2 . . . . . . . . . . . 21

J
jogging activation, parameter . . . . . . . . . . . . . . . 108

H
hand-auto macro . . . . . . . . . . . . . . . . . . . . . . . . . 76 heat loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 hood (IP54 / UL type 12) . . . . . . . . . . . . . . . . 17, 30 how to do common tasks with Assistant Control Panel . . . . . . . . . . . . . 44 with Basic Control Panel . . . . . . . . . . . . . . . . 63

K
keypad see control panel keypad reference select, parameter . . . . . . . . . . 109 kWh counter, data parameter. . . . . . . . . . . . . . . . 100 intake energy, data parameter . . . . . . . . . . . 103

I
I/O settings (Assistant Control Panel) . . . . . . . . . 61 I/O, control through . . . . . . . . . . . . . . . . . . . . . . . 38 id run fail, fault code . . . . . . . . . . . . . . . . . . . . . . . 246 parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 performing. . . . . . . . . . . . . . . . . . . . . . . . . . . 39 identification magnetization . . . . . . . . . . . . . . . . . 99 IEC ratings see ratings impedance grounded network see IT system incompatible software, fault code . . . . . . . . . . . 247 information, parameter group . . . . . . . . . . . . . . 146 input power cable/wire requirements . . . . . . . . . . . . . . . 265 disconnecting device (disconnecting means) 263 specifications . . . . . . . . . . . . . . . . . . . . . . . 263 input power connection IT system . . . . . . . . . . . . . . . . . . . . . . . . . . 268 lugs for R6 . . . . . . . . . . . . . . . . . . . . . . . . . 269 terminal size . . . . . . . . . . . . . . . . . . . . . . . . 268 torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 installation check list . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 compatibility . . . . . . . . . . . . . . . . . . . . . . . . . 14 environment . . . . . . . . . . . . . . . . . . . . . . . . . 14 flow chart . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 mounting drive . . . . . . . . . . . . . . . . . . . . . . . 17 preparation . . . . . . . . . . . . . . . . . . . . . . . . . . 12 procedures . . . . . . . . . . . . . . . . . . . . . . . . . . 11 tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 wiring overview . . . . . . . . . . . . . . . . . . . . . . . 18 insulation check. . . . . . . . . . . . . . . . . . . . . . . . . . 24

L
label serial number . . . . . . . . . . . . . . . . . . . . . . . . . 12 type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 language, parameter . . . . . . . . . . . . . . . . . . . . . . 98 LED on Assistant Control Panel. . . . . . . 42, 243, 244 on drive body . . . . . . . . . . . . . . . . . 20, 243, 244 liability limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . 294 limits, parameter group . . . . . . . . . . . . . . . . . . . . 125 load curve, see user load curve load frequency, see user load curve load torque, see user load curve loading package version, parameter . . . . . . . . . 146 LOC (local control) indication on Assistant Control Panel. . . . . . . 43 indication on Basic Control Panel . . . . . . . . . 62 local control mode lock, parameter. . . . . . . . . . . 122 lock control panel access, IP54 . . . . . . . . . . . . . . . 30 drive control at local control panel . . . . . . . . 122 parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 121 low frequency (PFC), parameters. . . . . . . . . . . . 177 lugs for R6 power cables . . . . . . . . . . . . . . . . . . . 269 ring, crimp-on . . . . . . . . . . . . . . . . . . . . . . . . 269 terminal, screw-on . . . . . . . . . . . . . . . . . . . . 270

Index

ACS550 Users Manual

303

M
macros 3-wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 ABB standard (default) . . . . . . . . . . . . . . . . . 72 alternate . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 hand-auto . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 motor potentiometer . . . . . . . . . . . . . . . . . . . 75 PFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 PID control . . . . . . . . . . . . . . . . . . . . . . . . . . 77 torque control . . . . . . . . . . . . . . . . . . . . . . . . 79 user parameter sets . . . . . . . . . . . . . . . . . . . 81 parameter default values. . . . . . . . . . . . . . . . 82 parameters not changed . . . . . . . . . . . . . . . . 71 magnetization, identification . . . . . . . . . . . . . . . . 99 main menu Assistant Control Panel. . . . . . . . . . . . . . . . . 44 Basic Control Panel. . . . . . . . . . . . . . . . . . . . 63 mains see input power maintenance capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . 258 control panel . . . . . . . . . . . . . . . . . . . . . . . . 258 heat sink . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 internal enclosure fan . . . . . . . . . . . . . . . . . 257 intervals. . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 main fan . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 triggers, parameter group . . . . . . . . . . . . . . 139 manuals list of ACS550 manuals. . . . . . . . . . . . . . . . . . 2 providing feedback . . . . . . . . . . . . . . . . . . . 309 mapping actual value, FBA, generic profile . . . . . . . . 241 EFB modbus . . . . . . . . . . . . . . . . . . . . . . . . 202 materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 maximum frequency, parameter . . . . . . . . . . . . . . . . . 126 torque limit, parameters . . . . . . . . . . . . . . . 127 torque select, parameter . . . . . . . . . . . . . . . 126 mechanical angle, data parameter . . . . . . . . . . . . . . . . . 102 revolutions, data parameter . . . . . . . . . . . . 102 minimum frequency, parameter . . . . . . . . . . . . . . . . . 126 torque limit, parameters . . . . . . . . . . . . . . . 126 torque select, parameter . . . . . . . . . . . . . . . 126 modbus EFB addressing, convention . . . . . . . . . . . . 202 EFB coils . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 EFB discrete inputs . . . . . . . . . . . . . . . . . . . 204 EFB holding registers . . . . . . . . . . . . . . . . . 205 EFB input registers . . . . . . . . . . . . . . . . . . . 205 EFB mapping details . . . . . . . . . . . . . . . . . . 202 EFB mapping summary. . . . . . . . . . . . . . . . 202 EFB supported features . . . . . . . . . . . . . . . 201 EFB technical data . . . . . . . . . . . . . . . . . . . 201

motor checking insulation . . . . . . . . . . . . . . . . . . . . . 24 compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . 14 id run, parameter . . . . . . . . . . . . . . . . . . . . . . 99 load curve break point frequency . . . . . . . . . 141 load curve max., fault parameter . . . . . . . . . 141 load curve zero speed load . . . . . . . . . . . . . 141 maintenance triggers . . . . . . . . . . . . . . . . . . 139 nominal current, parameter . . . . . . . . . . . . . . 99 nominal frequency, parameter . . . . . . . . . . . . 99 nominal power, parameter . . . . . . . . . . . . . . . 99 nominal speed, parameter . . . . . . . . . . . . . . . 99 nominal voltage, parameter . . . . . . . . . . . . . . 98 phase, fault code . . . . . . . . . . . . . . . . . . . . . 247 requirements . . . . . . . . . . . . . . . . . . . . . . . . . 14 stall, fault code . . . . . . . . . . . . . . . . . . . . . . . 246 thermal protection. . . . . . . . . . . . . . . . . . . . . 273 motor cable checking insulation . . . . . . . . . . . . . . . . . . . . . 24 length 400 V drives . . . . . . . . . . . . . . . . . . . . . . 272 600 V drives . . . . . . . . . . . . . . . . . . . . . . 273 max. length. . . . . . . . . . . . . . . . . . . . . . . . . . 271 requirements . . . . . . . . . . . . . . . . . . . . . . . . 274 requirements, EMC . . . . . . . . . . . . . . . . . . . 274 motor connection lugs for R6 . . . . . . . . . . . . . . . . . . . . . . . . . . 269 terminal size . . . . . . . . . . . . . . . . . . . . . . . . . 268 torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 motor control parameter group. . . . . . . . . . . . . . . . . . . . . . 137 control mode, parameter . . . . . . . . . . . . . . . . 98 IR compensation, parameters . . . . . . . . . . . 137 motor potentiometer macro. . . . . . . . . . . . . . . . . . 75 motor temperature measure, parameter group. . . . . . . . . . . . . . 150 alarm limit, parameter. . . . . . . . . . . . . . . . . . 151 data parameter . . . . . . . . . . . . . . . . . . . . . . . 102 fault limit, parameter. . . . . . . . . . . . . . . . . . . 151 overtemperature, fault code . . . . . . . . . . . . . 245 sensor selection, parameter . . . . . . . . . . . . . 151 sensor type, parameter . . . . . . . . . . . . . . . . 151 thermal protection. . . . . . . . . . . . . . . . . . . . . 273 thermal protection, fault parameter . . . . . . . 140 thermal time, fault parameter . . . . . . . . . . . . 140 motor, auxiliary aux start order, parameter . . . . . . . . . . . . . . 186 aux. start delay (PFC), parameter . . . . . . . . 177 aux. stop delay (PFC), parameter . . . . . . . . 177 number of aux., parameter . . . . . . . . . . . . . . 178 mounting dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 286 template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 MWh counter, data parameter . . . . . . . . . . . . . . . . 102 intake energy, data parameter . . . . . . . . . . . 103 power consumption, maintenance trigger . . 139

N
NEMA ratings see ratings noise random sw. freq. parameter . . . . . . . . . . . . . 138

Index

304

ACS550 Users Manual

NPN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

O
offset (PID), parameter . . . . . . . . . . . . . . . . . . . 168 ok messages (count), parameter. . . . . . . . . . . . 172 operating data, parameter group. . . . . . . . . . . . 100 operation Assistant Control Panel . . . . . . . . . . . . . . . . 43 Basic Control Panel . . . . . . . . . . . . . . . . . . . 63 OPEX link, fault code . . . . . . . . . . . . . . . . . . . . 246 OPEX power, fault code . . . . . . . . . . . . . . . . . . 246 options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 parameter group . . . . . . . . . . . . . . . . . . . . . 187 code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 output frequency, data parameter . . . . . . . . . . . . . 100 voltage, data parameter . . . . . . . . . . . . . . . 100 wiring, fault code . . . . . . . . . . . . . . . . . . . . . 247 output mode Assistant Control Panel . . . . . . . . . . . . . . . . 47 Basic Control Panel . . . . . . . . . . . . . . . . . . . 65 overcurrent automatic reset, parameter . . . . . . . . . . . . . 143 fault code . . . . . . . . . . . . . . . . . . . . . . . . . . 244 overload curve see user load curve overspeed, fault code . . . . . . . . . . . . . . . . . . . . 247 overvoltage control enable, parameter . . . . . . . . . . . . . . 125

parity (RS-232), parameter . . . . . . . . . . . . . . . . . . 172 errors (count), parameter . . . . . . . . . . . . . . . 172 patents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295 PE earth earth fault, parameter. . . . . . . . . . . . . . . . . . 141 PE earth connection terminal size . . . . . . . . . . . . . . . . . . . . . . . . . 268 torque . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 PELV (Protective Extra Low Voltage) . . . . . . . . . . 23 PFC control, parameter group . . . . . . . . . . . . . . . 175 acceleration time, parameter . . . . . . . . . . . . 186 aux start order, parameter . . . . . . . . . . . . . . 186 aux. motor start delay, parameter . . . . . . . . 177 aux. motor stop delay, parameter . . . . . . . . 177 deceleration time, parameter . . . . . . . . . . . . 186 enable, parameter . . . . . . . . . . . . . . . . . . . . 185 low frequency, parameters. . . . . . . . . . . . . . 177 macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 number of aux. motors, parameter. . . . . . . . 178 number of motors parameter . . . . . . . . . . . . 186 reference step, parameters . . . . . . . . . . . . . 175 start delay, parameter . . . . . . . . . . . . . . . . . 185 start frequency, parameters . . . . . . . . . . . . . 176

P
panel communication, parameter group . . . . . . 172 panel display variables, parameter group . . . . . 147 panel firmware version . . . . . . . . . . . . . . . . . 41, 45 panel loss, fault code. . . . . . . . . . . . . . . . . . . . . 245 parameter analog input scale, fault code . . . . . . . . . . . 248 analog output scale, fault code . . . . . . . . . . 248 change lock. . . . . . . . . . . . . . . . . . . . . . . . . 121 descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . 98 external relay output, fault code . . . . . . . . . 248 fieldbus, fault code . . . . . . . . . . . . . . . . . . . 248 hz rpm, fault code . . . . . . . . . . . . . . . . . . . . 248 listing (ranges, resolutions, defaults) . . . . . . 85 PCU 1 (power control unit), fault code . . . . 249 PCU 2 (power control unit), fault code . . . . 248 PFC IO, fault code . . . . . . . . . . . . . . . . . . . 249 PFC mode, fault code . . . . . . . . . . . . . . . . . 248 PFC ref. neg., fault code . . . . . . . . . . . . . . . 248 save changes . . . . . . . . . . . . . . . . . . . . . . . 122 table version, parameter . . . . . . . . . . . . . . . 146 user load curve, fault code . . . . . . . . . . . . . 249 view, parameter . . . . . . . . . . . . . . . . . . . . . 124 parameter mode Assistant Control Panel . . . . . . . . . . . . . . . . 49 Basic Control Panel . . . . . . . . . . . . . . . . . . . 67 parameter restore Assistant Control Panel . . . . . . . . . . . . . . . . 58 Basic Control Panel . . . . . . . . . . . . . . . . . . . 69

Index

ACS550 Users Manual

305

PID

process sets, parameter groups . . . . . . . . . 159 external / trimming, parameter group . . . . . 168 0% (actual signal), parameter . . . . . . . . . . . 162 100% (actual signal), parameter . . . . . . . . . 162 actual input select, parameters . . . . . . . . . . 164 actual value max., parameters . . . . . . . . . . 164 actual value min., parameters . . . . . . . . . . . 164 adjustment procedure . . . . . . . . . . . . . . . . . 160 comm value 1, data parameter . . . . . . . . . . 103 comm value 2, data parameter . . . . . . . . . . 103 control macro . . . . . . . . . . . . . . . . . . . . . . . . 77 correction source, parameter . . . . . . . . . . . 169 decimal point (actual signal), parameter . . . 161 derivation filter, parameter . . . . . . . . . . . . . 161 derivation time, parameter . . . . . . . . . . . . . 161 deviation, data parameter . . . . . . . . . . . . . . 101 error feedback inversion, parameter . . . . . . 161 external source activate, parameter . . . . . . 168 feedback multiplier, parameter . . . . . . . . . . 163 feedback select, parameter. . . . . . . . . . . . . 163 feedback, data parameter . . . . . . . . . . . . . . 101 gain, parameter . . . . . . . . . . . . . . . . . . . . . . 160 integration time, parameter . . . . . . . . . . . . . 161 internal setpoint, parameter . . . . . . . . . . . . 163 offset, parameter . . . . . . . . . . . . . . . . . . . . . 168 output, data parameter . . . . . . . . . . . . . . . . 101 parameter set select, parameter . . . . . . . . . 166 scaling (0100%), parameters. . . . . . . . . . 162 setpoint maximum, parameter. . . . . . . . . . . 163 setpoint minimum, parameter . . . . . . . . . . . 163 setpoint select, parameter. . . . . . . . . . . . . . 162 setpoint source, EFB comm activate. . . . . . 196 setpoint source, FBA comm, activate . . . . . 228 setpoint, data parameter . . . . . . . . . . . . . . . 101 sleep delay, parameter . . . . . . . . . . . . . . . . 165 sleep level, parameter. . . . . . . . . . . . . . . . . 165 sleep selection, parameter . . . . . . . . . . . . . 164 trim mode, parameter . . . . . . . . . . . . . . . . . 168 trim scale, parameter . . . . . . . . . . . . . . . . . 168 units (actual signal), parameter. . . . . . . . . . 161 wake-up delay, parameter. . . . . . . . . . . . . . 165 wake-up deviation, parameter. . . . . . . . . . . 165 PID controller advanced set-up . . . . . . . . . . . . . . . . . . . . . 160 basic set-up. . . . . . . . . . . . . . . . . . . . . . . . . 159 planning EFB comm . . . . . . . . . . . . . . . . . . . . . . . . . 190 FBA comm . . . . . . . . . . . . . . . . . . . . . . . . . 223 PNP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 power consumption (MWh) maintenance trigger . . 139 data parameter . . . . . . . . . . . . . . . . . . . . . . 100 previous faults, history parameters . . . . . . . . . . 106 process PID sets, parameter groups . . . . . . . . . 159 process variables, data parameter . . . . . . . . . . 102 product inquiries. . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 training . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 profiles, EFB comm . . . . . . . . . . . . . . . . . . . . . . 202 proportional gain, parameter . . . . . . . . . . . . . . . 133

protection circuit, required w/ chopper . . . . . . . . . . . . . 280 disconnecting device (disconnecting means) 263 enclosure standard. . . . . . . . . . . . . . . . . . . . 291 environmental . . . . . . . . . . . . . . . . . . . . . . . . 289 motor thermal . . . . . . . . . . . . . . . . . . . . . . . . 273 PT100 temperature sensor . . . . . . . . . . . . . . . . . 151 PTC temperature sensor. . . . . . . . . . . . . . . . . . . 151

R
radiation limits, conducted EN 61800-3 . . . . . . . . . . . . . . . . . . . . . . . . . 275 ramp pair (accel/decel), parameter . . . . . . . . . . . 131 range listing for parameters . . . . . . . . . . . . . . . . . 85 ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 reference select, parameter group . . . . . . . . . . . . . . . . 109 corrections for parameter values . . . . . . . . . 110 keypad control, parameter . . . . . . . . . . . . . . 109 maximum, parameters . . . . . . . . . . . . . . . . . 111 minimum, parameters. . . . . . . . . . . . . . . . . . 111 mode (Basic Control Panel) . . . . . . . . . . . . . . 66 select source, parameter . . . . . . . . . . . . . . . 109 step (PFC), parameters . . . . . . . . . . . . . . . . 175 reference scaling EFB, ABB drives profile . . . . . . . . . . . . . . . . 218 FBA, ABB drives profile . . . . . . . . . . . . . . . . 236 FBA, generic profile . . . . . . . . . . . . . . . . . . . 240 reference setting Assistant Control Panel . . . . . . . . . . . . . . . . . 48 Basic Control Panel . . . . . . . . . . . . . . . . . . . . 66 regulator by-pass control, parameter . . . . . . . . . 185 relative humidity environment limit . . . . . . . . . . . . . . . . . . . . . 289 shipping limit. . . . . . . . . . . . . . . . . . . . . . . . . 289 relay output parameter group. . . . . . . . . . . . . . . . . . . . . . 116 activation condition parameters . . . . . . . . . . 116 off-delay, parameters . . . . . . . . . . . . . . . . . . 117 on-delay, parameters . . . . . . . . . . . . . . . . . . 117 status, data parameter . . . . . . . . . . . . . . . . . 101 relays, specifications. . . . . . . . . . . . . . . . . . . . . . 281 REM (remote control) indication on Assistant Control Panel. . . . . . . 43 indication on Basic Control Panel. . . . . . . . . . 62 remove cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 reset, automatic parameter group. . . . . . . . . . . . . . . . . . . . . . 143 analog input less than min., parameter . . . . 143 delay time, parameter. . . . . . . . . . . . . . . . . . 143 external fault, parameter . . . . . . . . . . . . . . . 143 number of trials, parameter . . . . . . . . . . . . . 143 overcurrent, parameter . . . . . . . . . . . . . . . . . 143 trial time, parameter . . . . . . . . . . . . . . . . . . . 143 undervoltage, parameter . . . . . . . . . . . . . . . 143 resolution listing for parameters . . . . . . . . . . . . . . 85 resonance (avoiding) select, parameter . . . . . . . . . . . . . . . . . . . . . 136 revolution counter, data parameter . . . . . . . . . . . 102 revolutions, mechanical, data parameter . . . . . . 102 ring lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269

Index

306

ACS550 Users Manual

RS-232 baud rate, parameter . . . . . . . . . . . . . . . . . 172 parity, parameter. . . . . . . . . . . . . . . . . . . . . 172 station id, parameter . . . . . . . . . . . . . . . . . . 172 RS-232 counts buffer overruns, parameter . . . . . . . . . . . . . 172 CRC errors, parameter . . . . . . . . . . . . . . . . 172 frame errors, parameter . . . . . . . . . . . . . . . 172 ok messages, parameter . . . . . . . . . . . . . . 172 parity errors, parameter . . . . . . . . . . . . . . . 172 RS485 comm. . . . . . . . . . . . . . . . . . . . . . . . . . . 190 run enable source select, parameter. . . . . . . . . 121 run time data parameter . . . . . . . . . . . . . . . . . . 100, 102 maintenance trigger . . . . . . . . . . . . . . . . . . 139

S
safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 save changes parameter. . . . . . . . . . . . . . . . . . 122 scalar:frequency mode . . . . . . . . . . . . . . . . . . . . 98 scaling actual value, FBA, ABB drives profile . . . . . 239 actual value, FBA, generic profile . . . . . . . . 241 actual values, EFB comm . . . . . . . . . . . . . . 197 reference, EFB, ABB drives profile . . . . . . . 218 reference, FBA, ABB drives profile . . . . . . . 236 reference, FBA, generic profile . . . . . . . . . . 240 screw-on terminal lugs . . . . . . . . . . . . . . . . . . . 270 s-curve ramp, parameter . . . . . . . . . . . . . . . . . . 131 second environment (C3), compliance with IEC/EN 61800-3 . . . 293 (C3), motor cable length . . . . . . . . . . . . . . . 272 definition . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 sensor type, parameter . . . . . . . . . . . . . . . . . . . 151 sensorless vector control mode. . . . . . . . . . . . . . 98 serial 1 error (fault code 28) . . . . . . . . . . . . . . . 200 serial 1 error, fault code. . . . . . . . . . . . . . . . . . . 247 serial communication see EFB (embedded fieldbus) see EFB, drive parameters see FBA (fieldbus adapter) see FBA, drive parameters serial number. . . . . . . . . . . . . . . . . . . . . . . . . 12, 13 service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 setpoint maximum (PID), parameter . . . . . . . . . 163 setpoint minimum (PID), parameter . . . . . . . . . 163 setpoint select (PID), parameter . . . . . . . . . . . . 162 shock, stress testing . . . . . . . . . . . . . . . . . . . . . 290 short circuit, fault code . . . . . . . . . . . . . . . . . . . 245 single phase supply connection . . . . . . . . . . . . . . . . . . . . . . . . . . 18 derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 sleep selection (PID), parameter. . . . . . . . . . . . 164 slip compensation ratio, parameter . . . . . . . . . . 138 soft keys (Assistant Control Panel) . . . . . . . . . . . 42 specifications control connections . . . . . . . . . . . . . . . . . . . 281 input power . . . . . . . . . . . . . . . . . . . . . . . . . 263 mains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 263

speed and direction (signed), data parameter . . . . 100 at fault, history parameter . . . . . . . . . . . . . . 106 data parameter. . . . . . . . . . . . . . . . . . . . . . . 100 max. limit, parameter . . . . . . . . . . . . . . . . . . 125 min. limit, parameter. . . . . . . . . . . . . . . . . . . 125 speed control parameter group. . . . . . . . . . . . . . . . . . . . . . 133 acceleration compensation, parameter . . . . 134 automatic tuning, parameter . . . . . . . . 133, 134 derivation time, parameter . . . . . . . . . . . . . . 133 integration time, parameter . . . . . . . . . . . . . 133 proportional gain, parameter . . . . . . . . . . . . 133 vector:speed mode. . . . . . . . . . . . . . . . . . . . . 98 speed, constant parameter group. . . . . . . . . . . . . . . . . . . . . . 112 digital input selection parameter . . . . . . . . . 112 parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 113 stall frequency, fault parameter . . . . . . . . . . . . . . 141 function, fault parameter . . . . . . . . . . . . . . . 141 region . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 time, fault parameter . . . . . . . . . . . . . . . . . . 141 standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 C22.2 No. 14 . . . . . . . . . . . . . . . . . . . . . . . . 291 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . 291 CSA marking . . . . . . . . . . . . . . . . . . . . . . . . 292 C-Tick marking . . . . . . . . . . . . . . . . . . . . . . . 291 EN 50178 . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 IEC 60664-1 . . . . . . . . . . . . . . . . . . . . . . . . . 291 IEC/EN 60204-1 . . . . . . . . . . . . . . . . . . . . . . 291 IEC/EN 60529 . . . . . . . . . . . . . . . . . . . . . . . 291 IEC/EN 61800-3 . . . . . . . . . . . . . . . . . . . . . . 291 IEC/EN 61800-5-1 . . . . . . . . . . . . . . . . . . . . 291 UL 508C . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 UL marking. . . . . . . . . . . . . . . . . . . . . . . . . . 292 start parameter group. . . . . . . . . . . . . . . . . . . . . . 128 aux. motor (PFC), parameters . . . . . . . . . . . 176 aux. motor delay. . . . . . . . . . . . . . . . . . . . . . 177 control, EFB comm. . . . . . . . . . . . . . . . . . . . 193 control, FBA comm. . . . . . . . . . . . . . . . . . . . 225 DC magnetizing time, parameter . . . . . . . . . 128 delay (PFC), parameter . . . . . . . . . . . . . . . . 185 delay, parameter . . . . . . . . . . . . . . . . . . . . . 130 frequency (PFC), parameters. . . . . . . . . . . . 176 function, parameter . . . . . . . . . . . . . . . . . . . 128 inhibit, parameter . . . . . . . . . . . . . . . . . . . . . 129 select enable source, parameter . . . . . . . . . 123 torque boost current, parameter. . . . . . . . . . 129 start mode automatic . . . . . . . . . . . . . . . . . . . . . . . . . . . 128 automatic torque boost. . . . . . . . . . . . . . . . . 128 DC magnetizing . . . . . . . . . . . . . . . . . . . . . . 128 flying start. . . . . . . . . . . . . . . . . . . . . . . . . . . 128 start/stop parameter group. . . . . . . . . . . . . . . . . . . . . . 128 with Assistant Control Panel . . . . . . . . . . . . . 46 with Basic Control Panel . . . . . . . . . . . . . . . . 64 start/stop/dir, parameter group . . . . . . . . . . . . . . 107 starting order counter . . . . . . . . . . . . . . . . . . . . . 180

Index

ACS550 Users Manual

307

start-up assistant . . . . . . . . . . . . . . . . . . . . . . . . . 36, 51 data, parameter group. . . . . . . . . . . . . . . . . . 98 guided, Assistant Control Panel . . . . . . . . . . 36 limited, Assistant or Basic Control Panel . . . 31 state diagram comm (EFB) . . . . . . . . . . . . . . . . . . . . . . . . 217 comm, ABB drives. . . . . . . . . . . . . . . . . . . . 235 station id (RS-232), parameter . . . . . . . . . . . . . 172 status at fault, history parameter . . . . . . . . . . . . 106 status word ABB drives, FBA, description . . . . . . . . . . . 233 EFB comm, definition . . . . . . . . . . . . . . . . . 212 FBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 FBA generic profile . . . . . . . . . . . . . . . . . . . 240 stop parameter group . . . . . . . . . . . . . . . . . . . . . 128 aux. motor (PFC), parameters . . . . . . . . . . 177 aux. motor delay . . . . . . . . . . . . . . . . . . . . . 177 DC brake time, parameter. . . . . . . . . . . . . . 129 DC current control, parameter. . . . . . . . . . . 128 DC current ref., parameter . . . . . . . . . . . . . 129 emergency devices . . . . . . . . . . . . . . . . . . . 265 emergency select, parameter . . . . . . . . . . . 129 flux braking, parameter . . . . . . . . . . . . . . . . 137 function, parameter . . . . . . . . . . . . . . . . . . . 128 stress tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 supervision parameter group . . . . . . . . . . . . . . . . . . . . . 144 parameter low limit, parameters . . . . . . . . . 144 parameter selection, parameters . . . . . . . . 144 supply phase, fault code . . . . . . . . . . . . . . . . . . 246 switching frequency . . . . . . . . . . . . . . . . . . . . . . 271 control, parameter . . . . . . . . . . . . . . . . . . . . 138 derating . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 parameter . . . . . . . . . . . . . . . . . . . . . . . . . . 138 symmetrically grounded network see corner grounded TN system system controls, parameter group . . . . . . . . . . . 121

tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 top cover, see hood torque at fault, history parameter. . . . . . . . . . . . . . . 106 boost current, parameter . . . . . . . . . . . . . . . 129 data parameter . . . . . . . . . . . . . . . . . . . . . . . 100 max. limit select, parameter . . . . . . . . . . . . . 126 max. limit, parameter . . . . . . . . . . . . . . . . . . 127 min. limit select, parameter . . . . . . . . . . . . . 126 min. limit, parameters . . . . . . . . . . . . . . . . . . 126 ramp down, parameter . . . . . . . . . . . . . . . . . 135 ramp up, parameter . . . . . . . . . . . . . . . . . . . 135 torque control parameter group. . . . . . . . . . . . . . . . . . . . . . 135 macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 ramp down, parameter . . . . . . . . . . . . . . . . . 135 ramp up, parameter . . . . . . . . . . . . . . . . . . . 135 vector:torque mode . . . . . . . . . . . . . . . . . . . . 98 training . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 trim mode (PID), parameter. . . . . . . . . . . . . . . . . 168 scale (PID), parameter . . . . . . . . . . . . . . . . . 168 two-wire sensor, connection example. . . . . . . . . . 80 type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12, 13

U
U/f ratio, parameter . . . . . . . . . . . . . . . . . . . . . . . 137 UL/CSA markings . . . . . . . . . . . . . . . . . . . . . . . . 292 underload curve see user load curve undervoltage automatic reset, parameter . . . . . . . . . . . . . 143 control enable, parameter . . . . . . . . . . . . . . 125 ungrounded network see IT system units (PID), parameter. . . . . . . . . . . . . . . . . . . . . 161 unknown drive type, fault code . . . . . . . . . . . . . . 248 unpacking drive. . . . . . . . . . . . . . . . . . . . . . . . . . . 12 unsymmetrically grounded networks see corner grounded TN system user load curve parameter group. . . . . . . . . . . . . . . . . . . . . . 156 fault code . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 frequency, parameters . . . . . . . . . . . . . 156, 157 function, parameter . . . . . . . . . . . . . . . . . . . 156 mode, parameter . . . . . . . . . . . . . . . . . . . . . 156 time, parameter . . . . . . . . . . . . . . . . . . . . . . 156 torque, parameters . . . . . . . . . . . . . . . . 156, 157 user parameter set . . . . . . . . . . . . . . . . . . . . . . . . 81 change control, parameter . . . . . . . . . . . . . . 122 download . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58

T
temperature derating . . . . . . . . . . . . . . . . . . . . . 262 template, mounting . . . . . . . . . . . . . . . . . . . . . . . 16 terminal lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 terminals control, description . . . . . . . . . . . . . . . . . . . . 22 control, specifications . . . . . . . . . . . . . . . . . 282 location diagram, R1R4 . . . . . . . . . . . . . . . 20 location diagram, R5/R6 . . . . . . . . . . . . . . . . 21 termination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 test date, parameter . . . . . . . . . . . . . . . . . . . . . 146 thermal fail, fault code . . . . . . . . . . . . . . . . . . . . 246 timed functions parameter group . . . . . . . . . . . . . . . . . . . . . 152 autochange, parameter . . . . . . . . . . . . . . . . 186 booster, parameter . . . . . . . . . . . . . . . . . . . 154 enable, parameter . . . . . . . . . . . . . . . . . . . . 153 source, parameter . . . . . . . . . . . . . . . . . . . . 154 speed control. . . . . . . . . . . . . . . . . . . . . . . . 114 start time, parameter . . . . . . . . . . . . . . . . . . 153 stop time, parameter . . . . . . . . . . . . . . . . . . 153 timed mode, parameter . . . . . . . . . . . . . . . . . . . 114

V
vector: speed mode . . . . . . . . . . . . . . . . . . . . . . . . . . 98 torque mode . . . . . . . . . . . . . . . . . . . . . . . . . . 98 version firmware, parameter . . . . . . . . . . . . . . . . 60, 146 loading package, parameter. . . . . . . . . . . . . 146 panel firmware . . . . . . . . . . . . . . . . . . . . . 41, 45 parameter table, parameter . . . . . . . . . . . . . 146

Index

308

ACS550 Users Manual

vibration, stress testing . . . . . . . . . . . . . . . . . . . 290 voltage at fault, history parameter . . . . . . . . . . . . . . 106 rating code . . . . . . . . . . . . . . . . . . . . . . . . . . 13 voltage/frequency ratio, parameter . . . . . . . . . . 137

W
wake-up delay (PID), parameter . . . . . . . . . . . . . . . . 165 deviation (PID), parameter . . . . . . . . . . . . . 165 warning automatic start up . . . . . . . . . . . . . . . . . . . . . . 6 dangerous voltages . . . . . . . . . . . . . . . . . . . . 5 disconnecting device (disconnecting means) . 6 ELV (Extra Low Voltage) . . . . . . . . . . . . . . . 23 EM1, EM3, F1 and F2 screws. . . . . . . . . . . . . 6 filter on corner grounded TN system. . . . . . . . 6 filter on IT system . . . . . . . . . . . . . . . . . . . . . . 6 high temperatures . . . . . . . . . . . . . . . . . . . . . . 6 listing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 not field repairable . . . . . . . . . . . . . . . . . . . . . 6 parallel control connections . . . . . . . . . . . . . . 5 qualified installer . . . . . . . . . . . . . . . . . . . . . . . 5 weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288 wiring control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 fault, parameter. . . . . . . . . . . . . . . . . . . . . . 142 installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 installation steps, IP21/cables . . . . . . . . . . . 25 installation steps, IP21/conduit . . . . . . . . . . . 26 installation steps, IP54/cables . . . . . . . . . . . 27 installation steps, IP54/conduit . . . . . . . . . . . 28 overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 requirements, general . . . . . . . . . . . . . . . . . . 18

XYZ
zero pulse detected, data parameter . . . . . . . . . . . . . . enable, parameter. . . . . . . . . . . . . . . . . . . . zero speed delay, parameter . . . . . . . . . . . . . . . . . . . . . load, fault parameter . . . . . . . . . . . . . . . . . . 102 170 130 141

Index

Contact ABB
Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type code and serial number of the drive in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/drives and selecting Drives World wide service contacts on the right pane. Product training For information on ABB product training, navigate to www.abb.com/drives and select Drives Training courses on the right pane. Providing feedback on ABB Drives manuals Your comments on our manuals are welcome. Go to www.abb.com/drives, then select successively Drives Document Library Manuals feedback form (LV AC drives) on the right pane.

SUPERSE DES: 3AUA0000 001418 Rev E 06.12.2004

3AFE6480 4588 (3AUA000 0001418) Rev F / EN

SUPERSE DES: 3AFE6480 4588 Rev D 24.06.2004

EFFECTIV E: 16.04.2007

ABB Oy AC Drives P.O. Box 184 FI-00381 HELSINKI FINLAND Telephone +358 10 22 11 Fax +358 10 22 22681 Internet www.abb.com

ABB Inc. Automation Technologies Drives & Motors 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone +1 262 785-3200 +1 800-HELP-365 Fax +1 262 780-5135

ABB Beijing Drive Systems Co. Ltd. No. 1, Block D, A-10 Jiuxianqiao Beilu Chaoyang District Beijing, P.R. China, 100015 Telephone +86 10 5821 7788 Fax +86 10 5821 7618 Internet www.abb.com

You might also like