You are on page 1of 18

PLUMBING TERMS ABS ACCESIBLE AERATION AIR BREAK AIR CHAMBER AIR DRAIN AIR GAP AIR GAP,

DRAINAGE AIR GAP, WATER DISTRIBUTION

AIR SPACE AIR VENT ALLEY ALTER / ALTERATION ANGLE VALVE APGA B&S BACK SIPHONAGE BACK VENT BACK WATER VALVE BACKBEND PIPE BACKFLOW BACKFLOW CONNECTION BACKFLOW PREVENTER BACKPRESSURE BACKFLOW BALL COCK BALL JOINT BALL VALVE BATHROOM BATTERY OF FIXTURE BELL OR HUB BENDING PIN or IRON BIBB BIDET BLANK FLANGE BLIND FLANGE

BLOW-OFF BOILER BLOW-OFF BRANCH BRANCH FIXTURE

BRANCH INTERVAL BRANCH VENT / HOR. VENT / GROUP VENT BRAZED JOINT BUILDING BUILDING DRAIN BUILDING SEWER BUILDING SUBDRAIN BUILDING SUPPLY BUILDING TRAP CAP CATCH BASIN CAULKING

CESSPOOL CHASE CHECK VALVE CIRCUIT VENT / LOOP VENT CISTERN CLARIFIER CLOSE NIPPLE COLD JOINT COMBINATION WASTE & VENT SYSTEM COMBUSTIBLE CONSTRUCTION COMMON VENT COMPREESED AIR

COMPRESSION COCK
CONDUCTOR CONFINED SPACE CONTAMINATION

CONTINIOUS VENT CONTINIOUS WASTE CORPORATION COCK COUPLING COURT CPVC CRITICAL LEVEL CROSS CONNECTION DEAD END DEVELOPED LENGTH DIAMETER DOMESTIC SEWAGE DOUBLE BEND FITTING DOUBLE OFFSET DOWNFEED DOWNSPOUT DRAIN DRAIN WASTE VENT DRAINAGE SYSTEM DRY VENT DUAL VENT

DURHAM SYSTEM EFFECTIVE OPENING ELASTROMETRIC GASKETED & RUBBER-RING JOINTS EQUIVALENT LENGTH FAUCET FERRULE FIXTURE FIXTURE BRANCH (DRAINAGE) FIXTURE BRANCH (SUPPLY) FIXTURE DRAIN FIXTURE SUPPLY FIXTURE UNIT

FLANGING FLASHING FLOAT VALVE FLOOD LEVEL FLOOD LEVEL RIM FLOW VALVE

FLUSH TANK FLUSH VALVE

FLUSHOMETER TANK GATE VALVE GLOBE VALVE GOOSE NECK GRADE GREASE INTERCEPTOR GREASE TRAP GROUND WATER GROUP VENT HANGERS

HARDNESS
HEIGHT OF BUILDING HIGH HAZARD

HORIZONTAL BRANCH HORIZONTAL PIPE HOUSE DRAIN HOUSE SEWER HOUSE STORM SEWER HUBLESS PIPE

INCINERATION
INDIRECT WASTE PIPE INSANITARY

INTERCEPTOR INVERT

JOCKEY PUMP LATERAL LATRINE LAVATORY LEACHING CESSPOOL LEACHING WELL LEADER LENGTH OF PIPE LOCAL VENT LOW HAZARD MAIN MAIN SEWER MAIN VENT MANHOLE MASTER PLUMBER MAXIMUM DEMAND NAMPAP NATIONAL PLUMBING CODE NIPPLE OAKUM OFFSET PB (POLIBUTYLENE) PE (POLYETHYLENE)

PERCOLATION TEST
PIPE PITCH PLUMBING PLUMBING APPLIANCE PLUMBING APPORTENANCE PLUMBING FIXTURE PLUMBING OFFICIAL PLUMBING SYSTEM PLUMBING UNIT POTABLE WATER PRESSURE GAUGE PRESSURE, RESIDUAL PRESSURE, STATIC PRIMARY BRANCH PRIVATE

PRIVATE SEWAGE DISPOSAL SYSTEM PRIVATE SEWER PRIVY PRIVY VAULT PUBLIC PUBLIC SEWER PVC QUALITY OF MATERIALS

RA. 1378
RAIN WATER RECEPTOR REDUCER REGULATING EQUIPMENT RELIEF VENT REPAIR RETURN BEND RISER ROOF LEADER

ROUGHING-IN

SAFETY VALVE
SAND FILTER SANITARY SEWAGE

SANITARY SEWER SANITARY TEE SEAL SECONDARY BRANCH SEDIMENTATION SEEPAGE PIT / DRY WELL / LEACHIND CESSPOOL SEPTIC TANK SERVICE PIPE SEWAGE

SEWAGE EJECTOR SEWER SEWERAGE WORK SHAFT SHALLOW WELL SHIELDED COUPLING SIAMESE CONNECTION SIPHONAGE SITZ BATH SIZE OF TUBING SLIP JOINT SLOPE SINK SOIL PIPE SOIL STACK PIPE SOIL WATER DRAIN SOLDERED JOINT SPECIAL WASTE SPIGOT SPRINGKLER HEAD STACK PIPE STACK VENT STANDPIPE

STATIC HEAD
STOREY STORM WATER STREET SEWER SUBSOIL DRAIN SUMP SUMP PUMP SUPPORTS SURFACE WATER TAIL PIECE TAPPED TEE TELEPHONE SHOWER

THREADED JOINTS

TRAP TRAP ARM TRAP PRIMER TRAP SEAL TUBE TUNGSTEN INNER GAS UNCONFINED SPACE UNION ELBOW UNIT VENT UPFEED VACUUM VACUUM BREAKER VACUUM RELIEF VALVE VENT PIPE VERTICAL PIPE WASHDOWN WATER CLOSET WASTE WASTE PIPE WASTE, INDUSTRIAL WASTE, LIQUID WASTE, WATER BORNE WATER TREATMENT WELDED JOINT WET VENT WINDOW WYE FITTING YACK VICE YOKE VENT ZEOLITE

PLUMBING TERMS PLASTIC PIPE USED WATER SERVICE, IRRIGATION. ALSO KNOWN "BLACK PIPE" WITHOUT CONSTRUCTION RAW WATER PASS TO A PIPES & EXPOSED TO AIR OF FINE MIST TO PURIFY IT SEPARATION BETWEEN WASTE PIPE & INDIRECT WASTE RECEPTION DEVICE USED TO PREVENT HAMMERING BY MINISHING THE WATER FORCE PRESENT IN THE WATER DISTRIBUTION SYSTEM RECEPTOR DESIGN TO COLLECT SURFACE OR STORM FROM A OPEN AREA. VERTICAL DISTANCE BETWEEN LOWEST OPENING TO FLOOD LEVEL ROOM UNOBSTRUCTED VERTICAL DISTANCE BETWEEN LOWEST OPENING TO FLOOD LEVEL ROOM UNOBSTRUCTED VERTICAL DISTANCE. POTABLE WATER THE GAP BETWEEN THE WATER LEVEL AND THE UNDERSIDE OF THE CONCRETE SLAB COVER OF A SEPTIC TANK WHERE FREE OXYGEN SUPPORTS BACTERIA IN THE PROCESS OF ORGANIC DECOMPOSITION TERMINAL DEVICE DESIGNED TO ALLOW THE PASSAGE OF FRESH AIR TO A SPACE FROM THE OUTSIDE 2-3 METERS DEDICATED FOR PUBLIC USE. CHANGE, ADDITION, MODIFICATION USE TO CONTROL WATER FLOW AT 90DEG. BEND. ASSOCIATED OF PHILIPPINES GOV, ARCHITECTURE BROWN & SHARPE (SPECIFICATION) BELL & SPIGOT (ENDS OF PIPE) NEGATIVE PRESSURE INDIVIDUAL VENT. REVENT PIPE PREVENT REVERSE FLOW INDIVIDUAL VENT WATER FROM ANY SOURCE OTHER THAN REGULAR SOURCE REVERSE FLOW CAN OCCUR VACUUM BREAKER. PREVENT FLOW OF LIQUID FROM RETURNING TO THE SOURCE INCREASED REVERSE PRESSURE ABOVE THE SUPPLY. AIR PRESSURE GREATER THAN ATMOSPHERIC PRESSURE. VALVE OF AN ATTACHED BALL FLOATING BALL SHAPED END HELD IN CUPLIKE.THAT ALLOW MOVEMENT IN EVERY DIRECTION. VALVE CONTAINING A PERPORATED BALL, WHICH CAN BE TURNED TO ALIGN WITH PORTS IN THE CASING AND ALLOW LIQUID TO PASS THROUGH ROOM WITH SHOWER STALL OR BATHTUB 2 OR MORE SIMILAR ADJACENT FIXTURES WHICH DISCHARGE INTO A COMMON HOR. SOIL BRANCH SUFFICIENTLY ENLARGE TO RECEIVE END OF PIPE OF THE SAME DIAMETER FOR MAKING A JOINT. STRAIGTHENING / BENDING LEAD PIPE FAUCET, COCK, TAP, PLUG WASHING THE MIDDLE PART OF BODY NOT DRILLED FOR BOLT HOLES CLOSES END OF PIPE

CONTROLLED OUTLET TO DISCHARGE LIQUID DETRITUS VALVE OUTLET TO DISCHARGE ACCUMULATED SEDIMENTS PART OF PIPING SYSTEM OTHER THAN MAIN, RISER, STACK SUPPLY PIPE LENGTH OF SOIL OR WASTE STACK CORRESPONDING IN GENERAL TO A STOREY HEIGHT, BUT IN NO CASE LESS THAN 2.43 MTS. WITHIN WHICH THE HORIZONTAL BRANCHES FROM ONE FLOOR OR STOREY OF A BLDG. ARE CONNECTED TO THE STACK. HORIZONTAL VENT CONNECTING ONE MORE INDIVIDUAL VERTICAL BACK VENT WITH THE VENT STACK AND THE STACK VENT. ANY JOINT OBTAINED BY JOINING OF METAL PARTS WITH ALLOYS W/C MELTS AT TEMPERATURE HIGHER THAN 449C STRUCTURE BUILT LOWEST HORIZONTAL PIPING W/C RECEIVES THE DISCHARGE FROM SOIL, WATER AND OTHER DRAINAGE PIPES INSIDE THE WALLS OF THE BUILDING. STARTS FROM THE END OF BUILDING DRAIN AND RECEIVES DISCHARGE FROM THE BUILDING DRAIN. CANNOT DRAIN BY GRAVITY INTO THE BUILDING SEWER WATER SERVICE CONNECTION PREVENT CIRCULATION OF AIR BETWEEN THE DRAINAGE PIPING SYSTEM OF THE BUILDING SEWER. CLOSING THE END OF THE PIPE OR FITTING HAVING A FEMALE THREAD RECEPTACLE IN W/C LIQUID ARE RETAINED TO ALLOWS SETTLEMENT MATERIALS TO PENETRATE. PLUGGING AN OPENING WITH OAKUM, LEAD. PREVENT LEAKAGE CESSPIT. TREATMENT OF WASTE WATER. UNDERGROUND STORAGE CONTAINER. EMPTIED AT REGULAR INTERVALS, FOR SEWAGE WHICH CANNOT BE PIPED AWAY FOR TREATMENT. VERTICAL SHAFT FOR INSTALLATION OF DIFFERENT PIPES. AUTOMATICALLY CLOSES TO PREVENT REVERSE DIRECTION CONNECTS TO A VENT STACK. UNDERGROUND WATER TANK INTERCEPTOR. GREASE TRAP. TYPE OF NIPPLE WITH THE ENTIRE LENGTH EXTERNALLY THREADED TYPE OF PIPE OF CONNECTION IN WHICH A BALL-SHAPED END IS HELD IN A CUPLIKE SHELL AND ALLOWS MOVEMENT IN EVERY DIRECTION. HORIZONTAL WET VENTING (SINKS / FLOOR DRAINS) BURN AT TEMPERATURE OF 756 C OR LESS UNIT VENT. DUAL VENT. GREATER THAN THE ATMOSPHERIC PRESSURE OF AIR AT ANY PRESSURE BIBB OPERATED BY THE COMPRESSION OF A SOFT PACKING UPON A METAL SHEET VERTICAL PIPE TO CONVEY RAINWATER. HAVING A VOLUME LESS THAN 1.4 CU.M. IMPAIRMENT OF POTABLE WATER. HIGH HAZARD

CONTINUATION OF THE DRAIN TO W/C VENT CONNECTS. DRAIN CONNECTING COMPARTMENTS STOP VALVE CONNECTED TO WATER SERVICE PIPE TO MAIN PVC FITTING USED TO CONNECT TWO STRAIGHT LINES OF PIPE OPEN, UNOCCUPIED SPACE PIPE FOR HOT WATER SUPPLY DETERMINES THE MAXIMUM ELEVATION ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE. CONNECTION OF PIPES BETWEEN TWO SEPERATE BLDG'S WATER SUPPLY PIPES OR SYSTEM. EXTENDED PORTION OF A PIPE CLOSED AT ONE END LENGTH OF PIPE AT CENTERLINE OF A PIPE AND FITTINGS NOMINAL DESIGN AS DESIGNATED COMMERCIALLY LIQUID/ WATER BORNE WASTES. FREE FROM INDUSTRIAL WASTE. PIPE FITTING W/C ADJACENT REVERSE BENDS AND SHAPED LIKE LETTER "S" 2 OFFSET IN SUCESSION SYSTEM OF WATER SUPPLY EMPLOYED WHEN AN ELEVATED TANK IS INSTALLED WITHIN THE BUILDING. VER. PORTION OF RAINWATER CONDUCTOR. THAT COLLECTS RAIN WATER. GROUND SURFACE WATER, STORM WATER, WASTE WATER IN BLDG. DRAINAGE SYSTEM. COMBINED SANITARY DRAINAGE AND VENTING SYSTEM. PIPINGS. CONVEY SEWAGE/ LIQUID WASTE. DOES NOT CARRY LIQUID OR WASTE-BORNE WASTES UNIT VENT TERM USED TO DESCRIBE SOIL OR WASTE SYSTEM WHERE ALL THREADED, TUBING OR RIGID CONNECTION USING RECESSED DRAINAGE FITTINGS TO CORRESPOND TO TE TYPES OF PIPING. CROSS SECTIONAL AREA OF WATER SUPPLY

NEOPRENE GASKETS ARE RECOMMENDED FOR OIL HANDLING PIPING WORKS. LENGTH OF STRAIGHT PIPE OF A SPECIFIC DIAMETER PRODUCE THE SAME FRICTIONAL RESISTANCE. VALVE LOCATED LOCATED AT THE END OF A WATER PIPE THROUGH OF WHICH WATER CAN BE DRAWN FROM OE HELD WITHIN THE PIPE. METALLIC SLEEVE. PLUG IS SCREWED THAT CAN BE REMOVED FOR THE PURPOSE OF CLEANING THE INSIDE RECEPTACLE OTHER THAN TRAP ATTACHED TO A PLUMBING SYSTEM IN WHICH WATER OR WASTES MAY BE COLLECTED OR RETAINED DRAIN PIPE FROM THE TRAP OF A FIXTURE TO THE JUNCTION OF THAT DRAIN WITH OTHER DRAIN WATER SUPPLY SOURCE CONNECTING THE FIXTURE AND SUPPLY PIPE FROM TRAP OF FIXTURE TO JUNCTION OF DRAIN WATER SUPPLY PIPE CONNECTING THE FIXTURE WITH THE FIXTURE BRANCH. FLOW OF WASTE USED FOR SIZING PLUMBING JOBS IN A PLUMBING SYSTEM EQUAL TO ONE CUBIC FOOT PER MINUTE.

TYPE OF JOINT FOR IRON PIPE SIZE AND FITTINGS SHALL BE MADE WITH FITTINGS MEETING APPROVED STANDARDS. THE TUBING SHALL BE EXPANDED WITH A PROPER FLARING TOOL. PIECE OF SHEET METAL FITTED UNDER ANOTHER PIECE OF FLAT METAL OR WOOD OVER WHICH WATER IS EXPECTED TO RUN. FITTING AUTOMATICALLY STOPS THE FLOW OF WATER IN THE TANK. CRITICAL LEVEL. WATER BEGINS TO OVERFLOW. TOP EDGE OF A RECEPTACLE FROM THE WATER OVERFLOWS. INDICATION OF WATER FLOW IN WET SPRINKLER SYSTEM TANK LOCATED LOCATED ABOVE OR INTEGRAL WITH WATER CLOSET, URINAL OR SIMILAR STRUCTURES FOR FLUSHING OR REMOVING EXCREMENTS IN THE FIXTURES. VALVE FOR DELIVERING A REGULATED AMOUNT OF FLUSHING WATER TO A SOIL APPLIANCE. INTEGRATED WITHIN AN AIR ACCUMULATOR VESSEL WHICH IS DESIGNED TO DISCHARGE A PREDETERMINED QUANTITY OF WATER INTO FIXTURES FOR FLUSHING PURPOSES. FULL-OPEN VALVE. RAISED-LOWERED BY THREADED SYSTEM TORTOUS PASSAGE. FITS AGAINTS THE VALVE SEAT. RETURN BEND. SUITABLE FOR KITCHEN SINK. 1 FT. X 3 IN. SLOPE, FALL, PITCH 3 CU.M. INTERCEPTOR SEPERATES GREASE OR OIL FROM THE WASTE WATER TO PREVENT THE CLOGGING OF PIPES STANDING-IN OR PASSING THROUGH BRANCH VENT THAT PERFORMS ITS FUNCTION FOR 2 OR MORE TRAPS. ANCHOR, BRANCKETS, CRADLES IMPORTANT CONCERN IN THE PRIVATE WATER SUPPLY FROM "GRADE LINE" TO HIGHEST POINT OF COPING CONTAMINATION DRAIN PIPE EXTENDING LATERALLY FROM A SOIL OR WASTE STACK OR BUILDING DRAIN OR WITHOUT VERTICAL SECTIONS OR BRANCHES FROM ONE OR MORE FIXTURES DRAINS AND CONDUCTS IT TO THE SOIL OR WASTE STACK OR TO THE BUILDING DRAIN. EXTENDING LATERALLY. INSTALLED PIPE OR FITTINGS ANGLE OF NOT MORE THAN 45 WITH THE HORIZONTAL. BUILDING DRAIN. LOWEST HORIZONTAL PIPING OF A SYSTEM WHICH RECEIVES THE DISCHARGE FROM SOIL, WASTE AND OTHER DRAINAGE PIPE. PART OF BUILDING EXTENDING OUTISDE TO ANY POINT OF DISCHARGE AND CONVEYING THE DRAINAGE OF ONE BUILDING SITE. PIPELINE FROM THE BLDG. TO THE PUBLIC STORM SEWER. = 6" PLAIN ENDS. BOLTED STEEL BANDS, NEOPRENE GASKET. COMMON WAY OF DISPOSING SOLIDS WASTE PIPE INDIRECTLY CONNECTED WITH BUILDING DRAINAGE. INJURIOUS TO HEALTH RECEPTACLE DESIGNED AND CONSTRUCTED TO INTERCEPT OR SEPARATE AND PREVENT THE PASSAGE OF SOIL, GREASE, SAND OR OTHER MATERIALS INTO THE DRAINAGE SYSTEM. LOWEST PORTION OF INSIDE OF PIPE THAT IS NOT VERTICAL

PUMP USED WHEN FIRE IS ABOUT TO START. SECONDARY PIPELINE. RECEIVES SEWAGE ONLY FROM BUILDING SEWERS. WATER CLOSET W/ TROUGH EXTENDS UNDER TWO OR MORE ADJACENT SEATS. WASH BASIN NON-WATERTIGHT LINED EXCAVATION. PERMITTING LIQUID TO SEEP. PIT OR INTERCEPTOR HAVING POROUS WALLS W/C PERMITS THE CONTENTS TO SEP INTO THE GROUND. GUTTER TO DOWNSPOUT MEASURED ALONG PIPE. CONVEY FOUL AIR TO OUTER AIR. POLLUTION PRINCIPAL PIPE OF SYSTEM OF CONTINOUS PIPING TO WHICH BRANCH CONNECTIONS CAN BE MADE. COMMON SEWER PRINCIPAL VENT PIPE OF A SYSTEM TO WHICH VENT CONNECTION CAN BE MADE. ACCESS CHAMBER PERSON WITH KNOWLEDGE OF AND EXPRERIENCE IN PLUMBING WHO EMPLOYS JOURNEYMEN PLUMBERS OR WHO CONDUCTS PLUMBING SYSTEM. MAX. WATER OF DISCHARGE FOR PLUMBING FIXTURES NAT'L MASTER PLUMBER ASSOCIATION OF THE PHIL. INC. CODE THAT PRESCRIBES REGULATIONS ON WATER PIPING INSTALLATION INSIDE BUILDINGS AND PREMISES SHORT LENGTH OF A PIPE WITH TREADS AT EACH END, USED TO CONNECT COUPLING OF FITTINGS. HEMP. ROPE SOAKED IN OIL TO MAKE IT WATERPROOF. COMBINATION OF ELBOWS AND BENDS IN PIPING LINE. BLACK, CROSS SECTIONAL, OVAL BLACK, CROSS SECTIONAL, CIRCULAR DETERMINE THE SIZE OF A LEACHING FIELD CYLINDRICAL CONDUIT GRADE ART AND TECHNIQUE OF INSTALLING PIPES, FIXTURES. SPECIAL CLASS DEVICE. EX: REF, DRINKING FOUNTAIN ADJUNCT TO PIPING SYSTEM & FIXTURES. EX: SHOWER HEAD FIXTURE, RECEPTACLE ADMINISTRATIVE AUTHORITY, ENFORCE NPCP. ALL WATER SUPPLY, DRAINAGE AND VENTING SYSTEM AND ALL FIXTURES AND THEIR TRAPS COMPLETE WITH THEIR CONNECTIONS. MIN. STANDARD QUANTITY WATER SATISFACTORY. 85% CORRECTED GADGET INDICATE THE PRESSURE IN WATER SUPPLY SYSTEM PRESSURE DROP. FRICTION LESS, HEAD METER. PRESSURE WITHOUT ANY FLOW MOTION SINGLE SLOPING DRAIN FROM THE BASE OF A STACK TO ITS JUNCTION W/ MAIN BLDG. DRAIN. PRIVATE USE

DISCHARGING TO SUBSURFACE DISPOSAL FIELD. PRIVATELY OWNED. NOT CONTROLLED BY PUBLIC AUTHORITY OUTHOUSE TOILET PIT BENEATH A PRIVY IN WHICH EXCREMENT COLLECTS. PUBLIC USE DIRECTLY CONTROL BY PRIVATE AUTHORITY. POTABLE WATER PIPING.\ FREE FROM DEFECTS PLUMBING LAW OF THE PHILIPPINES WATER PRECIPITATED AS RAIN RECEIVE DISCHARGE FROM INDIRECT WASTE. USED WHEN PIPE ARE OF DIFF. SIZES ARE CONNECTED IN THE SAME LINE VALVES & CONTROL PROVIDES CIRCULATION OF AIR BETWEEN DRAINAGE AND VENT SYSTEM. ACTS AS AUXILIARY VENT. RECONSTRUCTION OR RENEWAL OF ANY PART 2-90 BENDS, 180 BEND COPPER TUBING VERTICAL WATER PIPE/ EXTENDS ONE FULL STOREY TO CONVEY WATER TO BRANCHES OR FIXTURES. PIPE CONNECTED FROM BUILDING GUTTER TO THE DOWNSPOUT OR CONDUCTOR. INSTALLATION OF CERTAIN PARTS OF THE PLUMBING SYSTEM THAT CAN BE DONE BEFORE INSTALLATION OF THE FIXTURES INCLUDING DRAINAGE, VENTING AND WATER SUPPLY. USED ON WATER SYSTEM, HEATING SYSTEM, COMPRESSED AIR LINE WITH EXCESSIVE PRESSURE REMOVE SOLID OR COLLOIDAL MATERILA OF A TYPE THAT CANNOT REMOVE BY SEDIMENTATION FROM SEPTIC TANK. DOMESTIC SEWAGE. SEWER AGE CONTAINING HUMAN EXCREMENT AND LIQUID HOUSEHOLD WASTE. DOMESTIC SEWER. INTENDED TO RECEIVE SANITARY SEWAGE W/ OR W/O INDUSTRIAL WASTE AND W/O THE ADMIXTURE OF SURFACE WATER, STORM WATER OR DRAINAGE USED FOR SWIFT PASSAGE OF WATERBORNE WASTE. VERT. DISTANCE FROM CROWN WEIR OF A TRAP TO TOP DIP HOR. RUN OF PIPE EMANATING FROM A FIXTURE OR GROUP UP TO ITS JUNTION W/ THE PRIMARY BRANCH. SUSPENDED PATICLES SETTLED DOWN TO PURIFY WATER DRY WELL. LEACHING CESSPOOL. NON-WATERTIGHT LINED EXCAVATION IN THE GROUND WHICH RECEIVES THE DISCHARGE OF A SANITARY DRAINAGE SYSTEM. WATERTIGHT RECEPTACLE WHICH RECEIVES THE DISCHARGE OF A SANITARY PLUMBING SYSTEM APIPELINE WHICH CONVEYS WATER OR GAS FROM A SUPPLY MAIN TO A BUILDING LIQUID WASTE. STORM/ GROUND WATER. WASTEWATER

DEVICE USED TO ELEVATE SEWAGE AND LIQUID WASTES FROM A LOWER LEVEL TO A POINT OF DISCHARGE. PIPE / CONDUIT FOR CARRYING SEWAGE AND LIQUID WASTE. CONSTRUCTION FOR COLLECTION, TRANSPORTATION, PUMPING, TREATMENT, FINAL DISPOSITION OF SEWAGE. VERTICAL OPENING. ELEVATORS, DUMBWAITER, AIRWELL PIT 10-20 FT. BELOW THE GROUND SURFACE USE FOR DRAWING WATER ELASTROMETRIC SEALING GASKET. WYE CONNECTION USED ON FIRE LINES SO THAT TWO LINES OF HOSE MAY BE CONNECTED TO HYDRANT. SUCTION, LESS THAN ATMOSPHERIC PRESSURE. WASHING THE MIDDLE PART OF BODY OF THE ELDERLY DIAMETER OF A TUBE COMPRESSOR/ WASHER. FRICTION RING DEEP SINK. USSUALLY SET LOW. ESP. USED FOR EMPTYING PARTS OF DIRTY WATER. PIPE W/C CONVEYS THE DISCHARGE OF WATER CLOSETS, URINALS OR FIXTURE HAVING SIMILAR FUNCTION. VERTICAL DRAINAGE PIPE INTO WHICH IS SOIL WATER IS DISCHARGED INTO A SOIL DRAIN. HORIZONTAL PIPE BURIED BENEATH THE GROUND FOR LEADING SOIL WATER FROM A BUILDING TO A PRIVATE OR PUBLIC SEWER. JOINT SEALED BY SOLDERING. TEMP. BELOW 427 AND ABOVE 149 C USE INDIRECT WASTE PIPING/ RECEPTORS ENDS OF CAST IRON PIPES. GADGET AUTOMATICALLY SPOUT OUT WATER VERTICAL LINE OF SOIL, WASTE OR VENT PIPING VERTICAL EXTENSION OF A SOIL, WASTES OR VENT SYSTEM ABOVE THE HIGHEST HORIZONTAL DRAIN CONNECTED TO A STACK VERTICAL PIPE USUALLY USED FOR THE STORAGE OF WATER, FREQUENTLY UNDER PRESSURE. PART OF WATER SUPPLY DESIGN IS AFFECTED BY BUILDING HEIGHT. AREA BETWEEN VERTICALLY ADJACENT FLOORS OF A BUILDING RAINWATER LINE IN THE STREET WHERE SEVERAL SEWARAGE PIPELINE ARE CONNECTED BUILDING SUBDRAIN ARE UNDERGROUND DRAIN PIPES THAT RECEIVES ONLY SUBSURFACE OR SEEPAGE WATER AND CONVEY IT TO PLACE OF DISPOSAL PIT OR RECEPTACLE AT A LOW POINT TO WHICH THE LIQUID WASTE ARE DRAINED. EMPTIED BY MECH. MEANS PERMANENTLY INSTALLED DEVICE OTHER THAN EJECTOR FOR REMOVING SEWAGE OR LIQUID WASTE FROM A SUMP. HANGERS, ANCHOR, BRACKETS, CRADLES. RIVER, LAKES, SEA, OCEAN CUT PIECE. CAST IRON FITTING W/ THREAD. STREET ELBOW HAND HELD SHOWER TYPE OF JOINT FOR SOFT COPPER WATER, SHALL BE MADE WITH FITTINGS MEETING APPROVED STANDARDS. THE TUBING SHALL BE EXPANDED WITH A PROPER FLARING TOOL.

PREVENT BACKFLOW OF FOUL AIR/ METHANE GAS BET. TRAP & VENT. DIST - 1.50 M DEVICE OR SYSTEM OF PIPING TO MAINTAIN WATER SEAL IN A TRAP SEAL. WATER SEAL CONDUIT. CONDUCTOR (O.D.) BRACE JOINT FOR BRASS PIPE HAVING A VOLUME EQUAL TO AT LEAST 1.4 CU.M. OF AGGREGATE INPUT RATING OF FULL-BURNING APPLIANCE TYPE OF COUPLING ON ONE END SO THAT THE COUPLING END MAY BE CONNECTED TO THE END OF THE PIPE WITHOUT TURNING THE PIPE. COMMON VENT. DUAL VENT. SYSTEM OF WATER SUPPLY USED WHEN THE PRESSURE FROM THE CITY SUPPLY IS SUFFICIENT TO FURNISH THE DESIRED PRESSURE AT THE HIGHEST FIXTURE. AIR PRESSURE LESS THAN THAT ATMOSPHERIC. DESIGNED TO OPERATE UNDER CONDITIONED OF STATIC LINE PRESSURE. DEVICE TO PREVENT EXCESSIVE VACUUM IN A PRESSURE VESSEL. PIPE OR OPENING USED TO ENSURING THE CIRCULATION OF AIR IN PLUMBING SYSTEM AND FOR REDUCING THE PRESSURE EXERTED ON TRAP SEALS. NOT MORE THAN 45 W/ VERTICAL LINE DOES NOT HAVE FLUSH TANK. USED IN LOW COST HOUSING LIQUID WASTE. INDUSTRIAL WASTE. PIPE THAT CONVEYS ONLY LIQUID WASTE FREE OF FECAL MATTER FREE FROM FECAL MATTER. DISCHARGE FROM FIXTURE. NO FECAL MATTER W/ FECAL MATTER REMOVE SUSPENDED SOLID OF FILTRATION. SEAM. JOINING OF METAL PARTS IN PLASTIC MOLTEN STATE. VENT PIPE W/C LIQUID WASTE FLOWS. BEST REQUIREMENTS FOR TOILET ROOM VENTILATION HOSE CONNECTION W/ 2-GATED OUTLETS. USE AS CONNECTOR FOR SANITARY PIPES THREAD TOOL PIPE CONNECTING UPWARD FROM SOIL OR WASTE STACK TO A VENT STACK PREVENTING PRESSURE CHANGES IN THE STACK. TREATMENT OF HARD WATER

15.00 MTS 2% 1 1/2" 2" 3" 4" CDP HPDE PPRC PB PE PVC
AWWA IPS CPVC ABS

IPS 1.20m air space

20/40psi.

STANDARD DISTANCE OF WATER LINE FORM SEWER LINE AS PER NPCP FALL OR SLOPE OF A LINE OF PIPE IN REFERENCE TO A HORIZONTAL PLANE WASTE OUT SIZE OF A LAVATORY MIN. SIZE OF A TRAP OR BRANCH FOR A LAVATORY MINIMUM TRAP DIAMETER OF WATER CLOSET PRIVATE INSTALLATION PIPE CLEANOUT SIZE CONCRETE DRAINAGE PIPE
HIGH DENSITY POLYETHYLENE PIPE POLYPROPYLENE RAMDOM COPOLYMEK PIPE POLYBUTYLENE POLYBUTYLENE POLYVYNYL CHLORIDE AMERICAN WATER WORKS ASSOCIATION. IRON PIPE SIZE CHROLINATED POLYVINYL CHLORIDE ACRYLONITRILE BUTADIENE STYRENE

IRON PIPE SIZE


the min. water depth of the septic tank. the gap between the water level & the underside of the concrete slab cover of a septic tank where free oxygen supports bacteria in the process of organic decomposition. desired max. water pressure in faucet. a type of faucet/bibb operates by the compression of a soft packing upon a metal sht.