12 Volt 2.

0 AH

PS-1221

Features

Absorbent Glass Mat (AGM) technology for superior


performance
Valve regulated, spill proof construction allows safe
operation in any position
Power/volume ratio yielding unrivaled energy density
Rugged impact resistant ABS case and cover (UL94-HB)
Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and
C.A.B. certified
U.L. recognized under file number MH 20845
Terminals

Performance Specications

(mm)

Nominal Voltage ........................................................................ 12 volts (6 cells)

Pressure Contacts

Positive

Negative

10.5

Nominal Capacity

13.5
.5

.5

20-hr.

(100mA to 10.50 volts) ........................................................ 2.00 AH

10-hr.

(190mA to 10.50 volts) ....................................................... 1.90 AH

5-hr.

(340mA to 10.20 volts) ....................................................... 1.70 AH

1-hr.

(1.24A to 9.00 volts) ............................................................. 1.24 AH

15-min. (3.33A to 9.00 volts) .............................................................. 0.83 AH


Approximate Weight ........................................................... 1.30 lbs. (0.59 kg)

Physical Dimensions: in (mm)

Energy Density (20-hr. rate) ............................... 1.77 W-h/in3 (108.10 W-h/l)


Specic Energy (20-hr. rate) ............................. 18.46 W-h/lb (40.70 W-h/kg)
Internal Resistance (approx.) ..... This battery is protected by a bimetal circuit
breaker. If the current discharge temperature
rises above design limits the breaker is activated

Max Discharge Current (7 Min.) .................................................. 6.0 amperes


Max Short-Duration Discharge Current (10 Sec.) ....... n/a - battery is fused
Shelf Life (% of nominal capacity at 68F (20C))
CAUTION

Sealed Rechargeable
Battery

HT

MODEL PS-1221

MH20845

UST BE R

Pb

YCL ED

"SEALED LEAD BATTERY.


MUST BE RECYCLED OR
DISPOSED OF PROPERLY."

EC

12 Volt 2.0 Amp. Hr.

TTERY
BA

Do not make direct contact between battery terminals.


Do not discharge completely.
Recharge battery immediately after use.
Do not use other than specified battery charger.
Do not use below -10 C (15 F) or above + 40 C (105 F).
Recharge battery immediately after use.
If the temperature exceeds this upper limit,
a safety device will automatically prevent
operation of battery.

1 Month ...................................................................................................... 97%


3 Months ..................................................................................................... 91%

NONSPILLABLE

6 Months .................................................................................................... 83%


L

Operating Temperature Range


Charge .. .......................................................... 15F (-10C) to 105F (40C)

L: 5.63 (143) W: 0.94 (24) H: 2.56 (65) HT: 2.56 (65)


Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for
height dimensions. All data subject to change without notice.

Discharge ........................................................ 15F (-10C) to 105F (40C)


Case ...................................................................................................... ABS Plastic
Power-Sonic Chargers ................................................................... PSC-12300A

To ensure safe and efcient operation always refer to the latest edition of our Technical Manual, as published on our website.
All data subject to change without notice.

www.power-sonic.com

PS-1221 12 Volt 2.0 AH

Discharge Characteristics

100

Charging is not
necessary unless
100% of capacity
is required.

80

Charging before
use is necessary
to help recover
full capacity.

5oC
(41oF)

60
o

30 C
o
(86 F)

40oC
(104oF)

40
0

14.0

10

Charge may fail


to restore full
capacity. Do not
let batteries reach
this state.

20oC
(68oF)
12

14

16

18

20

12.0
11.0
10.0
9.0

2.4

12

24 36 48 1

Discharge Time

4 6 8 10

20 4 0

Life Characteristics in Stand-By Use

Retention Capacity (%)

min

20
15
10
Discharge Time

2.0
4.0

1.2

Discharge Time vs. Discharge Current

0.20 0.10

0.40

1.0

Final
Voltage

8.0

Standing Period (Months)

Ambient Temperature 20 C (68 F)

13.0

Terminal Voltage (V)

Capacity Retention Ratio (%)

Shelf Life & Storage

Final
Voltage
10.5V

10.2V

1
9.6V

min

30

9.0V

10
5

8.1V

0.10

0.20 0.40

1.0

2.0

80
60

20
0

Note: Due to the self-discharge characteristics of this type of battery, it is


imperative that they be charged within 6 months of storage, otherwise permanent
loss of capacity might occur as a result of sulfation.

Chargers

Life Characteristics in Cyclic Use


120

Retention Capacity (%)

Discharge Current (A)

Float or Stand-By Service: Hold battery across constant voltage source of


13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its
own current level and maintain itself in a fully charged condition.

Years

4.0

Cycle Applications: Limit initial current to 600mA. Charge until battery voltage
(under charge) reaches 14.4 to 14.7 volts at 68F (20C). Hold at 14.4 to 14.7
volts until current drops to under 20mA. Battery is fully charged under these
conditions, and charger should be disconnected or switched to float voltage.

Float Charging Voltage


2.25 - 2.30 V/Cell

40

40 C (104 F)
o
o
20 C (68 F)
o
o
0 C (32 F)

Charging

Ambient Temperature 20C (68F)

100

100
80
60

Discharge
Depth 100%

Discharge
Depth 50%

Discharge
Depth 30%

40
1. Discharge Current 0.2C (Final Voltage 1.7V/Cell)
2. Charge Current: 0.1C
3. Ambient Temperature: 20oC to 25oC (68oF to 77oF)

20
0

200

400

600

800

1000

1200

Number of Cycles

Further Information

Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH.


Please refer to the Charger Selection Guide in our specification sheets for C-Series
Switch Mode Chargers and Transformer Type A and F Series. Please contact our
Technical department for advice if you have difficulty in locating suitable models.

Please refer to our website www.power-sonic.com for a complete range of useful


downloads, such as product catalogs, material safety data sheets (MSDS), ISO
certification, etc..

Contact Information
DOMESTIC SALES
Tel: +1-619-661-2020
Fax: +1-619-661-3650
national-sales@power-sonic.com

www.power-sonic.com
CUSTOMER SERVICE
Tel: +1-619-661-2030
Fax: +1-619-661-3648
customer-service@power-sonic.com

TECHNICAL SUPPORT
Tel: +1-619-661-2020
Fax: +1-619-661-3648
support@power-sonic.com

INTERNATIONAL SALES
Tel: +1-650-364-5001
Fax: +1-650-366-3662
international-sales@power-sonic.com

CORPORATE OFFICE 7550 Panasonic Way San Diego, CA 92154 USA Tel: +1-619-661-2020 Fax: +1-619-661-3650
2011. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.

0211 1M

You might also like