PS-12750 12 Volt 75.

0 AH
Features

 Absorbent Glass Mat (AGM) technology for superior


performance
 Valve regulated, spill proof construction allows safe
operation in any position
 Power/volume ratio yielding unrivaled energy density
Rugged impact resistant ABS case and cover (UL94-HB)
Integrated ABS carrying handles for ease of movement
 Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and
C.A.B. certified
U.L. recognized under file number MH 20845
Terminals

(mm)
U: Positive Terminal

10
8.5

8.5

T6

Nominal Capacity

22

13

18

T 6: Threaded insert
w. 6 mm stud
fastener

Nominal Voltage......................................................................... 12 volts (6 cells)

15.9

22

10

17.4
18

U
 : Universal
terminals: Heavyduty posts with nut
& bolt fasteners

Performance Specifications

U: Negative Terminal

13

16
M6
6

20-hr. (3.75A to 10.50 volts) . ......................................................... 75.0 AH

10-hr. (7.2A to 10.50 volts) ............................................................. 72.0 AH

5-hr.

(13.6A to 10.20 volts) . ......................................................... 68.0 AH

1-hr.

(47A to 9.00 volts) ................................................................. 47.0 AH

15-min. (160A to 9.00 volts)................................................................ 40.0 AH

Approximate Weight ....................................................... 50.60 lbs. (22.95 kg)

Physical Dimensions: in (mm)

Energy Density (20-hr. rate) .................................. 1.63 W-h/in3 (99.61 W-h/l)


Specific Energy (20-hr. rate) . ............................. 17.79 W-h/lb (39.21 W-h/kg)
Internal Resistance (approx.) . ....................................................... 6 milliohms

Max Discharge Current (7 Min.) .............................................. 225.0 amperes


Max Short-Duration Discharge Current (10 Sec.)................. 560.0 amperes
Shelf Life (% of nominal capacity at 68F (20C))

Sealed Rechargeable
Battery

HT

MODEL PS-12750 U

12 Volt 75.0 Amp. Hr.

1 Month ...................................................................................................... 97%

3 Months...................................................................................................... 91%

6 Months . ................................................................................................... 83%

ST B E R
MU

Pb

YCL ED
EC

T TE RY
BA

MH20845

www.power-sonic.com

NONSPILLABLE

Operating Temperature Range


Charge... ........................................................... -4F (-20C) to 122F (50C)

Discharge........................................................ -40F (-40C) to 140F (60C)

L: 10.25 (260) W: 6.60 (168) H: 8.15 (207) HT: 8.98 (228)

Case....................................................................................................... ABS Plastic

Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for
height dimensions. All data subject to change without notice.

Power-Sonic Chargers.............................................................PSC-1210000A-C

To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
All data subject to change without notice.

www.power-sonic.com

PS-12750 12 Volt 75.0 AH

Constant Power Discharge Ratings


MODEL

WATTS PER CELL @ 25 C

FINAL
VOLTAGE

5 MIN

10 MIN

15 MIN

20 MIN

30 MIN

45 MIN

60 MIN

1.75

480

339

270

220

168

126

102

1.70

509

356

278

231

171

128

103

1.67

518

360

282

233

173

130

106

PS-12750

Discharge Characteristics

Discharge Time vs. Discharge Current


14.0

Discharge Time

Final
Voltage
10.5V

10.2V

1
9.6V

min

30

8.1V

3.75

7.5

15

12.0
11.0
10.0
9.0

37.5 75

1.2

40 C (104 F)
o
o
20 C (68 F)
o
o
0 C (32 F)

2.4

Note: Due to the self-discharge characteristics of this type of battery, it is


imperative that they be charged within 6 months of storage, otherwise permanent
loss of capacity might occur as a result of sulfation.

Chargers

24 36 48 1

4 6 8 10

20 4 0

Discharge Time

Shelf Life & Storage


Capacity Retention Ratio (%)

Float or Stand-By Service: Hold battery across constant voltage source of


13.5 to 13.8 volts continuously. When held at this voltage, the battery will seek its
own current level and maintain itself in a fully charged condition.

12

min

150

Cycle Applications: Limit initial current to 22.5A. Charge until battery voltage
(under charge) reaches 14.4 to 14.7 volts at 68F (20C). Hold at 14.4 to 14.7
volts until current drops to under 750mA. Battery is fully charged under these
conditions, and charger should be disconnected or switched to float voltage.

75
150

Discharge Current (A)

Charging

3.75

7.5

15

37.5

Final
Voltage

8.0
9.0V

10

Ambient Temperature 20 C (68 F)

13.0

Terminal Voltage (V)

20
15
10

100

Charging is not
necessary unless
100% of capacity
is required.

80

Charging before
use is necessary
to help recover
full capacity.

5oC
(41oF)

60

40
0

30 C
o
(86 F)

40oC
(104oF)
0

10

Charge may fail


to restore full
capacity. Do not
let batteries reach
this state.

20oC
(68oF)
12

14

16

18

20

Standing Period (Months)

Further Information

Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH.


Please refer to the Charger Selection Guide in our specification sheets for C-Series
Switch Mode Chargers and Transformer Type A and F Series. Please contact our
Technical department for advice if you have difficulty in locating suitable models.

Please refer to our website www.power-sonic.com for a complete range of useful


downloads, such as product catalogs, material safety data sheets (MSDS), ISO
certification, etc..

Contact Information
DOMESTIC SALES
Tel: +1-619-661-2020
Fax: +1-619-661-3650
national-sales@power-sonic.com

www.power-sonic.com
CUSTOMER SERVICE
Tel: +1-619-661-2030
Fax: +1-619-661-3648
customer-service@power-sonic.com

TECHNICAL SUPPORT
Tel: +1-619-661-2020
Fax: +1-619-661-3648
support@power-sonic.com

INTERNATIONAL SALES
Tel: +1-650-364-5001
Fax: +1-650-366-3662
international-sales@power-sonic.com

CORPORATE OFFICE 7550 Panasonic Way San Diego, CA 92154 USA Tel: +1-619-661-2020 Fax: +1-619-661-3650
2012. Power-Sonic Corporation. All rights reserved. All trademarks are the property of their respective owners.

0812 1M

You might also like