Two-third (2/3) rule or Ten-thirteen (10/13) rule ?

FOLLOW ME

Corporate Safety Training


electronicsecurityfiretraininginstitute.com Get expert training on fire safety Apply now for NSDC Certified course

Display prob lem ? Click HERE I have noticed there are many engineers still asking a simple question. In determining if a Pressure Relief Device is required for tube rupture, should we apply two-third (2/3) rule or ten-thirteen (10/13) rule ?

Enter your email address:

Subscribe

SUPPORT This Site

For those who has read my earlier post Criteria for Requirement of Pressure Relief Device for Tube Rupture may have aware that two-third (2/3) rule or ten-thirteen (10/13) rule are basically derivation of above criteria. Both are correct BUT subject to design code and revision of vessel being designed to. WHY two-third (2/3) rule ? Earlier revision of ASME required that equipment and piping be tested at 150% of stated design pressure. If the equipment design pressure is 15 barg, then the test pressure must be 22.5 barg, thus 15/22.5 = 2/3. API RP 521 (1997 edition) stated that if the design pressure of the lowpressure side (LPS) is at least 2/3 of the design pressure of the high pressure side (HPS), tube rupture is not con sidered a credible relieving scenario. WHY ten-thirteen (10/13) rule? In latest ASME, it stated that the test pressure of equipment to be 130% of the design pressure. If the equipment design pressure is 15 barg, then the test pressure shall be 19.5 barg, thus 15/19.5 = 10/13. Similarly follow API RP 521 (1997 edition) statement, if the design pressure of the low-pressure side (LPS) is at least 10/13 of the design pressure of the high pressure side (HPS), tube rupture is not considered a credible relieving scenario. In latest API STD 521, a more reasonable statement is the corrected test pressure of

webwormcpt.blogspot.in/2008/01/two-third-23-rule-or-ten-thirteen-1013.html

1/3

5/2/13

Chemical & Process Technology: Two-third (2/3) rule or Ten-thirteen (10/13) rule ?

low pressure side (LPS) is more than the design pressure of high pressure side (HPS), tube rupture may not be considered a credible relieving scenario. This statement is applicable to any test pressure requirement. WHY both are correct ? One shall remember, the equipment may be designed to latest ASME code which called for test pressure to be 130% of equipment design pressure. Then ten-thirteen (10/13) rule is applied. But if the vessel is designed to AS (Australia), GB (China), etc which both standards still call for equipment test pressure to be 150% of equipment design pressure with stress correction, then two-third (2/3) rule still applied. Thus, whenever consider a tube rupture scenario, the design code of the vessel shall always be taken into consideration. Nevertheless, latest API STD 521 statement still applicable in conjunction with equipment design to any code (ASME, AS, GB, JIS, etc). Updated : June 07, 2008 : "...within" changed to "...at least". Thanks to swakee. Sept 20, 2008 : "22.5/15" to "15/22.5"...

Related Topic
Tube Rupture : Pressure Relief Valve (PSV) or Rupture Disk (RD) ? Criteria for Requirement of Pressure Relief Device for Tube Rupture Requirement of Overpressure Protection Device on "Final Vessel" FREE & Reliable Pressure Relief Valve Sizing Software Extra Caution When Eliminating Overpressure by Fire Attacks Should maximum recommended wall temperature (Tw) for carbon steel vessel used as design temperature ? Should we install Butterfly valve for Pressure Relief Valve (PSV) isolation ? WebWorm Continue receive FREE stuff & Update.......Sub scrib e b y Email OR RSS Any comments / advices ?..........Drop it in comment field (b elow) or send a private email to me... Labels: Overpressure Protection

Process engineer jobs

Application Engineer-II
Expedia, Inc - Gurgaon, Haryana
eCommerce Application Engineer works with the Product... and accurately communicate to program managers, engineers, and senior management. Work Experience and... Expedia more jobs

Relief Valve API Flange ASME Flanges


Recommended Jobs Product Consultant Bangalore, Karnataka - UOP LLC Marketing Engineer Indore, Madhya Pradesh - Effort Consultancy Services Chemical Engineer - Process India - Customer is King

jobs by
posted by Webw orm, 2:19 PM

-->

4 Comments:
swakee said... As per this article for 2/3rd rule, it says "if design pressure of low pressure side (LPS)is within 2/3 of the design pressure of the high presure side, tube rupture is not consideredHigh pressure is not considered a credible relieving scenario". But API 521 says, the low pressure side is designed for atleast 2/3 of the design pressure of the high pressure side. Please correct the rule accordingly, otherwise this will mislead the people who refers this article. June 6, 2008 at 4:05 AM Webworm said... Thanks swakee. Updated. June 6, 2008 at 1:51 PM Anonymous said...

Chemical Engineer - Process Chennai, Tamil Nadu Customer is King Chemical Engineer - Process Bangalore, Karnataka Customer is King

Enter search terms... www.indeed.com

Go

webwormcpt.blogspot.in/2008/01/two-third-23-rule-or-ten-thirteen-1013.html

2/3

5/2/13

Chemical & Process Technology: Two-third (2/3) rule or Ten-thirteen (10/13) rule ?
In your "WHY two-third (2/3) rule?" paragraph, i think 22.5/15 is more than 1, so it should be 15/22.5. September 19, 2008 at 4:26 PM Webworm said... Sharp ! Thx September 19, 2008 at 5:26 PM

Post a Comment
Let us know your opinion !!! You can use some HTML tags, such as <b>, <i>, <a>