You are on page 1of 60

ACS800 Ordering Information

Frequency Converters
and Factory-Installed
Optional Devices
Code: 3AFY64556568
Effective from: 17 October 2011
Supersedes: 17 June 2011
Ordering Information
Updated: 12 October 2011
Overview
This document consists of:
- a Type Code Key
- ACS800-... Type Code Sheets (=Order Sheets).
Only the ACS 800 units and the built-in optional devices specified in this document can be
ordered with the codes given here. However, many of the optional devices are also
available as Add-On Kits, and these kits must be ordered separately. For the Add-On Kits
ordering codes, please see the ACS 800 price list.
The Type Code for ordering an ACS 800 unit consists of two parts: the characters in the
first part (min. 16 characters), identify the basic product with default features. The optional
devices are ordered by four-digit option codes which are separated by '+' signs. On the next
page you will find an example of a Type Code Key with legends. With the aid of the Type
Code Sheet you will be able to form the correct ordering code (technical definition) for the
unit(s) you wish to buy.
Various combinations of and restrictions to the available options are explained in detail on
the respective Option Sheets. Not released products are shown in grey
The Type Code Sheet filled in with the requested information about the basic product and
quantity of the selected options can be included in the order or you can copy the correct
Type Code onto your order sheet. Please send the order by Lotus Notes or by fax to the
country responsible Sales Administrator in Helsinki.
Type Code onto your order sheet. Please send the order by Lotus Notes or by fax to the
country responsible Sales Administrator in Helsinki.
Type Code Key
A C S 8 0 0 - 0 1 - 0 0 7 0 - 3 + X X X X +
Product Series
Construction
Size
Voltage Rating
Option codes
Example ACS800 - 01 - 0020 - 3 + E202 + 2L501 + L503
20 kVA 400 V basic drive
EMC filter
2pcs of Digital I/O extensions RDIO-01
DDCS Communication 3
Ordering Information
Updated on 12 October 2011
How to fill in the Industry Segment, Application Area and Distribution Channel
boxes on the Order Sheets
On the subsequent Order Sheets (Type Code Sheets), you will need to fill in the Industry Segment,
Application Area and Distribution Channel boxes on top of each sheet.
Below is a list of the Industry Segment, Application Area and Distribution Channel abbreviations
defined in our Order Processing System (SAP). On the Order Sheets, you may view these using the
Industry Segment, Application Area and Distribution Channel scroll bars and then select the respective
abbreviations from the Industry Segment, Application Area and Distribution Channel drop-down menus.
Abbreviations for Industry Segments and Application Areas (you may view these on the Order Sheets)
Industry Segments Application Areas
AUT - Automotive CAB - Cable car
CEM - Cement CAL - Calander line
CHE - Chemical CEN - Centrifuge
CON - Consumer industry COA - Coating
ELE - Electronics COM - Compressor
FOO - Food and Beverage CON - Conveyor
HVA - HVAC CRA - Crane
MAH - Material handling CRU - Crusher
MAR - Marine CUT - Cutting,Shear,Saw
MET - Metal DRI - Drilling
MIN - Mining DRU - Drum
MUL - Multiple segments OEM ELE - Elevator MUL - Multiple segments OEM ELE - Elevator
OFF - Offshore EXT - Extruder
OGA - Oil and Gas field FAN - Fan
PAP - Pulp and Paper FLA - Flat rolling
PEC - Petrochemical IND - Induction heating
PHA - Pharmaceutical KIL - Kiln
PRI - Printing MAC - Machinetool
POW - Power Plant MIX - Mixer,Stirrer
REC - Recreation PAC - Packaging machine
RUB - Rubber,Plastics PAP - Paper Machine
SAW - Sawmill POW - Power Electronics
TAD - Transmission and Distribution PRC - Processing line
TEX - Textile PRE - Press
WAT - Water PRI - Printing Machine
OTH - Other PRO - Profile rolling
NKN - Not Known PRP - Propulsion
PAR - Not known partner sales PUM - Pump
ROL - Roller table
Distribution Channels SKI - Skilift
SOL - Solar power
DSAL - Direct sales to end customer SPI - Spinning
SOEM - Serial OEM TES - Testbench
POEM - Project OEM THU - Thruster
LDIS - Electrical wholesaler WIC - Winch
TDIS - Technical distributor WID - Windmill
SINT - System integrator WIN - Winder
AHOU - EPCC and automation house NKN - Not Known
LCEN - Local ABB logistics centers OTH - Other
PBIN - Panel builders and installers PAR - Not known partner sales
AINT - ABB internal
Distribution Channel definitions:
Electrical Wholesalers (LDIS): Electrical Wholesalers/distributors has the ability to provide a wide
range of electrical products readily available from one location. Electrical Wholesalers/distributors
normally stocks leading brand name products, and the customer usually specifies the products
required from the catalogue. Electrical Wholesalers/distributors channels are cost driven and
normally use EDI-based ordering. This channel type includes Electrical wholesalers/distributors (e.g.
in US referred as electrical distributor), and also Catalogue houses.
Technical Distributor (TDIS): Technical product and service oriented channel. A technical
distributor has a good technical knowledge of the promoted product. Technical distributor offers
complementary products or services, which add value to the end customer. They do their business
locally, normally have a local stock and have a good working knowledge of local companies. This
channel type includes Drives Specialists, Motor repair shops, Power Transmission Distributors, but
partly also the immaterial channels like contractors, specifiers, consultants, representatives and
agents.
System Integrator (SINT): Technical solution oriented channel. System Integrators are specialized
in providing turn key automation solutions. System Integrator has value adding complementary
products and services in the offering. Business is normally done locally, and System Integrator has
a good working knowledge of local companies and standards. System Integrators are focused to
certain e.g. process industries.
EPCC and Automation House (AHOU): Complete automation solution oriented channel.
Automation Houses are specialized in providing the complete factory automation solutions as turn
key projects. Automation house uses They use one or several sub contractors to carry out the
automation project. Offering covers all the industrial automation products and/or systems. They
operate normally in several countries. EPCC (Engineering, Procurement and construction
contractors) agrees to deliver the keys of a commissioned plant to the owner for an agreed amount
Serial OEM (SOEM): Machine manufacturers that are purchasing products on the regular basis
(=serial) according to the predefined delivery schedule. The scope of supply of ABB product is also
Serial OEM (SOEM): Machine manufacturers that are purchasing products on the regular basis
(=serial) according to the predefined delivery schedule. The scope of supply of ABB product is also
predefined and does not vary significantly from customer to customer.
Project OEM (POEM): Machine manufacturer that purchases the product according to the frame
agreements made with the supplier. Purchase occurs after the project and the customer is known.
The Scope of supply varies from customer to customer.
Panel Builders and Installers (PBIN): Companies taking care of electrical panel building and panel
customization as well as installation of electrical equipments. Often working as sub-suppliers for
other more solution orientated industrial channels. They have good knowledge about local
standards.
Direct sales to end customer (DSAL): Sales directly from ABB to the end customers without using
intermediaries ( = without using other channels in the list above) ABB Internal: Sales to other ABB
units (stock orders, end customer not known)
Local ABB Logistic Center (LCEN): Purchases to local ABB logistic center without knowledge
about the final channel to the market.
ABB Internal (AINT): Sales to other ABB business units and ABB companies
ACS800-01 Type Code Sheet 1 - 200 kW, Wall Mounted
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 1 Construction
Channel
1014 - Size
Frame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6
230V 0001 0002 0003 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070
0004 0005
400V 0003 0004 0005 0011 0016 0020 0025 0030 0040 0050 0060 0100 0120 0135
0006 0009 0075 0165 0205
500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 0165
0009 0011 0105 0205 0255
690V 0011 0016 0050 0060 0070 0100 0120
0020 0025 0145 0175 0205
0030 0040
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
01 = Wall mounted, IP21 (UL type 1), With control panel CDP312R, No EMC
filter, Standard software, Cable lead through entry, Braking chopper in frame
sizes R2, R3 and R4 (only 690V), Boards without coating, One set of default
language documents
L516 available only with Motion control
and PMSM application softwares
L517 available only with standard control
and N651, N652, N654, N668, N677,
N685, N697 and N698 programs
!ndustry Segments Application Areas
Distribution Channels
ACS800-01 - 1 3AFY64556568
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
Communication board has always one
dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
and N651, N652, N654, N668, N677,
N685, N697 and N698 programs
ACS800-01 - 1 3AFY64556568
ACS800-01 Type Code Sheet 1 - 200 kW, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control *) Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Protection class
B056 IP55 (UL type 12)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-01 - 2 3AFY64556568
Construction
C131 Vibration dampers Only for R4, R5 and R6, not available with IP55 (B056)
C132 Marine Drive
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Resistor braking
D150 Braking chopper Included as standard in frame sizes R2 , R3 and 690V
frame R4
E202 not available for 690V units
Coated boards included. Requires Vibration dampers (C131) which are not needed, if
installed in a cabinet. Type approval of classicication socities. Only ABS, BV and
Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS
and BV for -0075-3, -0105-5, -0205-3 and -0255-5
ACS800-01 - 2 3AFY64556568
ACS800-01 Type Code Sheet 1 - 200 kW, Wall Mounted
Updated on 12 October 2011
Cabling
H358 Cable conduit entry (US & UK version)
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards Not applicable with C132
P904 Extended warranty
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
ACS800-01 - 3 3AFY64556568 ACS800-01 - 3 3AFY64556568
ACS800-02 Type Code Sheet 90 - 500 kW, Free standing
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 2 Construction
Channel
1014 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
400V 0140 0170 0260 0320 0400
0210 0440 0490
500V 0170 0210 0320 0400 0440
0260 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
02 = Free standing, 6 pulse diode bridge, IP21 (UL type 1), With control
panel CDP312R, No EMC filter, Standard software, Bottom entry and exit of
cables, Cable lead through entry, Boards without coating, One set of default
language documents
L516 available only with Motion
!ndustry Segments
Application Areas
Distribution Channels
ACS800-02 - 1 3AFY64556568
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
Communication board has always one
dedicated slot.
Modbus adapter can be used with other
Fieldbus adapter
L516 available only with Motion
control and PMSM control
L517 available only with standard
control and N651, N652, N654,
N668, N677, N685, N697 and N698
programs
ACS800-02 - 1 3AFY64556568
ACS800-02 Type Code Sheet 90 - 500 kW, Free standing
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Filters
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-02 - 2 3AFY64556568
Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E208 Common mode filter
Resistor braking
D150 Braking chopper
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards
P904 Extended warranty
E202 not available for 690V units neither for R8 frame
size
ACS800-02 - 2 3AFY64556568
ACS800-04 Type Code Sheet 1 - 200 kW, Drive module
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 4 Construction
Channel
1014 - Size
Frame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6
230V 0001 0002 0003 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070
0004 0005
400V 0003 0004 0005 0011 0016 0020 0025 0030 0040 0050 0060 0100 0120 0135
0006 0009 0023 0035 0075 0165 0205
500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 0165
0009 0011 0028 0045 0105 0205 0255
690V 0011 0016 0050 0060 0070 0100 0120
0020 0025 0145 0175 0205
0030 0040
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
04 = Module, IP20 (UL Open type),No control panel, No EMC filter,
Standard application software, Braking chopper in frame sizes R2, R3 and
R4 (only 690V), Boards without coating, One set of default language
documents
L516 available only with Motion control and
PMSM control
L517 available only with standard application
program and N651, N652, N654, N668,
N677, N685, N697 and N698 programs
!ndustry Segments Application Areas
Distribution Channels
!ndustry Segments Application Areas
Distribution Channels
ACS800-04 (R2-R6) - 1 3AFY64556568
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O, the
other only for motor temp. measurement
With motion control sw it is possible to have
1 or 2 pulse encoder/resolver interfaces
Communication board has always one
dedicated slot.
Modbus adapter can be used with other
Fieldbus adapter
ACS800-04 (R2-R6) - 1 3AFY64556568 ACS800-04 (R2-R6) - 1 3AFY64556568
ACS800-04 Type Code Sheet 1 - 200 kW, Drive module
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
J400 CDP312R control panel in module (in R2 - R4 includes also the J414 holder)
J414 Control panel holder for frame sizes R2 - R4 (not to be used with J400 option)
Construction
C132 Marine Drive
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
Coated boards included. Type approval of classicication socities. Only ABS, BV and
Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS and
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
ACS800-04 (R2-R6) - 2 3AFY64556568
C132 Marine Drive
C135 Flange mounting
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Resistor braking
D150 Braking chopper
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Included as standard in frame sizes R2 , R3 and 690V
frame R4
E202 not available for 690V units
C135: Flange mounting plate ready assembled. Heat sink side IP55, front
side IP20.
Coated boards included. Type approval of classicication socities. Only ABS, BV and
Lloyd's for -0135-3, -0165-3, -0165-5, -0205-5, -0145-7, -0175-7 and -0205-7. ABS and
BV for -0075-3, -0105-5, -0205-3 and -0255-5
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
ACS800-04 (R2-R6) - 2 3AFY64556568 ACS800-04 (R2-R6) - 2 3AFY64556568
ACS800-04 Type Code Sheet 1 - 200 kW, Drive module
Updated on 12 October 2011
Documentation language
0R715 No documentation
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards Not applicable with C132
P904 Extended warranty
+0R715: Module is delivered without manuals. This needs to be
approved by customer.
ACS800-04 (R2-R6) - 3 3AFY64556568 ACS800-04 (R2-R6) - 3 3AFY64556568 ACS800-04 (R2-R6) - 3 3AFY64556568
ACS800-04 Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 4 Construction
Channel
1014 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
400V 0140 0170 0260 0320 0400
0210 0440 0490
500V 0170 0210 0320 0400 0440
0260 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
04 = Drive module, 6 pulse diode bridge, IP00 (UL Open type), Top entry of
cables, side exit, RDCU motor control and I/O unit, No control panel, No
EMC filter, Standard software, Boards without coating, Bookshelf pedestal
with output busbars for motor, Bars for floor and wall fixing, One set of default
language documents
L516 available only with Motion control
and PMSM control
L517 available only with standard
!ndustry Segments
Application Areas
Distribution Channels
ACS800-04(R7-R8) - 1 3AFY64556568
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
With motion control sw it is possible to
have 1 or 2 pulse encoder/resolver
interfaces
Communication board has always one
dedicated slot.
Modbus adapter can be used with other
Fieldbus adapter
L516 available only with Motion control
and PMSM control
L517 available only with standard
application program and N651, N652,
N654, N668, N677, N685, N697 and
N698 programs
ACS800-04(R7-R8) - 1 3AFY64556568
ACS800-04 Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
J400 CDP 312R control panel (incl. 3 m control panel cable)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-04(R7-R8) - 2 3AFY64556568
J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
J413
Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E208 Common mode filter
Resistor braking
D150
Pedestal
0H354 No pedestal
Braking chopper (Including output busbar kit for braking chopper and DC unless +0H354 has been
selected)
RPMP-21 control panel mounting platform ("pocket" model to be mounted inside
the enclosure without control panel)
ACS800-04(R7-R8) - 2 3AFY64556568
ACS800-04 Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Documentation language
0R715 No documentation
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards
P904 Extended warranty
+0R715: Module is delivered without manuals. This
needs to be approved by customer.
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
ACS800-04(R7-R8) - 3 3AFY64556568 ACS800-04(R7-R8) - 3 3AFY64556568
ACS800-04M Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 4 M Construction
Channel
1014 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
400V 0140 0170 0260 0320 0400
0210 0440 0490
500V 0170 0210 0320 0400 0440
0260 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
04M = Modular drive module, 6 pulse diode bridge, IP00 (UL Open type), Top
entry of cables, exit requires pedestal, RDCU motor control and I/O unit, No
control panel, No EMC filter, Standard software, Boards without coating, No
pedestal, No output busbars, One set of default language documents,
Pedestal & mechanical accessories delivered as loose parts
L516 available only with Motion control and
PMSM control
!ndustry Segments
Application Areas
Distribution Channels
ACS800-04M - 1 3AFY64556568
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
With motion control sw it is possible to
have 1 or 2 pulse encoder/resolver
interfaces
Communication board has always one
dedicated slot.
Modbus adapter can be used with other
Fieldbus adapter
L516 available only with Motion control and
PMSM control
L517 available only with standard
application program and N651, N652,
N654, N668, N677, N685, N697 and N698
programs
ACS800-04M - 1 3AFY64556568
ACS800-04M Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
J400 CDP 312R control panel (incl. 3 m control panel cable)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-04M - 2 3AFY64556568
J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
J413
Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E208 Common mode filter
Resistor braking
D150 Braking chopper (if +H354 or +H360 are selected, select also +H356)
Pedestal, pedestal accessories
H352
H354 Bookshelf pedestal (alternatives H352 and H360)
H360 Flat type ("side against wall") mounting pedestal (alternatives H352 and H354)
H356 Pedestal busbar kit for DC and braking chopper outputs (requires +H354 or +H360)
H355
H362
H363
RPMP-21 control panel mounting platform ("pocket" model to be mounted inside the enclosure
without control panel)
Vertical busbars for motor output cable connection (incl. also supports for busbars). Requires +H354
or +H360.
Kit for DC and brake outputs on different sides (one long horisontal pedestal busbar, one extra
vertical busbar, one extra support for vertical busbars). Requires +H354 AND +H356.
Vertical busbars for DC and braking chopper output cable connection. Requires pedestal +H354 or
+H360 and DC busbar kit +H356.
Bottom exit kit (available only for R7; wall mounting; includes DC and braking chopper busbars;
alternatives H354 and H360)
E202 not available for 690V units
ACS800-04M - 2 3AFY64556568
ACS800-04M Type Code Sheet 90 - 560 kW, Drive module
Updated on 12 October 2011
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
B060
Documentation language
0R715 No documentation
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards
P904 Extended warranty
IP20 shroud. Available only for R7 frame size bottom exit version (+H352) and R8 frame size
bookshelf version with vertical busbars (+H354 +H355).
+0R715: Module is delivered without manuals. This
needs to be approved by customer.
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
ACS800-04M - 3 3AFY64556568 ACS800-04M - 3 3AFY64556568
ACS800-U1 Type Code Sheet 1 - 200 HP, Wall Mounted
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - U 1 Construction
Channel
1014 - Size
Frame Size R2 Frame Size R3 Frame Size R4 Frame Size R5 Frame Size R6
230V 0002 0003 0004 0006 0009 0011 0016 0020 0025 0030 0040 0050 0060 0070
500V 0004 0005 0006 0016 0020 0025 0030 0040 0050 0060 0070 0120 0140 0205
0009 0011 0105
690V 0011 0016 0050 0060 0070 0100 0120
(600V) 0020 0025 0145 0175 0205
0030 0040
1516 - Voltage Rating
2 = 230 V 5 = 500 V 7 = 690 V (600V)
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
U1 = Wall mounted (USA), UL type1 (IP21), With control panel CDP312R, No
EMC filter, Standard software (US), Cable conduit entry, Braking chopper in
frame sizes R2, R3 and R4 (only 600V), Boards without coating, One set of
default language documents
1 or 2 Digital extensions
L516 available only with Motion control
and PMSM control
L517 available only with standard
application program and N651, N652,
N654, N668, N677, N685, N697 and
N698 programs
!ndustry Segments
Application Areas
Distribution Channels
ACS800-U1 - 1 3AFY64556568
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
Communication board has always one
dedicated slot.
Modbus adapter can be used with other
Fieldbus adapter
ACS800-U1 - 1 3AFY64556568
ACS800-U1 Type Code Sheet 1 - 150 HP, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Protection class
B056 IP55 (UL type 12)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be
checked from ACS800 software compatibility document (doc
no. 3AFE64638211) in ABB Library
ACS800-U1 - 2 3AFY64556568
Construction
C131 Vibration dampers Only for R4, R5 and R6, not available with UL type 12 (B056)
C132 Marine Drive
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frames R2 - R5 only
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, frame R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Resistor braking
D150 Braking chopper
Cabling
H357 Cable lead through entry (European)
E202 not available for 690V units
Included as standard in frame sizes R2 , R3 and
690V (600V) frame R4
Coated boards included. Requires Vibration dampers (C131) which are not needed, if
installed in a cabinet. Type approval of classicication socities. Only ABS, BV and Lloyd's
for -0205-5, -0145-7, -0175-7 and -0205-7
ACS800-U1 - 2 3AFY64556568
ACS800-U1 Type Code Sheet 1 - 150 HP, Wall Mounted
Updated on 12 October 2011
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards Not applicable with C132
P904 Extended warranty
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
ACS800-U1 - 3 3AFY64556568 ACS800-U1 - 3 3AFY64556568
ACS800-U4 Type Code Sheet 150 - 600 HP, Drive module
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - U 4 Construction
Channel
1014 - Size
Frame Size R7 Frame Size R8
230V 0080 0100 0140 0170 0210
0120 0230 0260 0300
500V 0170 0210 0270 0300 0320 0400
0260 0440 0490 0550 0610
690V 0140 0170 0320 0400 0440
0210 0260 0490 0550 0610
1516 - Voltage Rating
2 = 230 V 5 = 500 V 7 = 690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
U4 = Drive module (USA), 6 pulse diode bridge, UL Open type (IP00), Top entry
of cables, side exit, RDCU motor control and I/O unit, No control panel, No EMC
filter, Standard software (US), Common mode filter in R8, Bookshelf pedestal
with output busbars for motor, Bars for floor and wall fixing, One set of default
language documents
L516 available only with Motion control and
PMSM control
L517 available only with standard
application program and N651, N652,
N654, N668, N677, N685, N697 and N698
programs
!ndustry Segments
Application Areas
Distribution Channels
ACS800-U4 - 1 3AFY64556568
L517 Pulse encoder interface TTL RTAC-03
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
With motion control sw it is possible to
have 1 or 2 pulse encoder/resolver
interfaces
Communication board has always one
dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
N654, N668, N677, N685, N697 and N698
programs
ACS800-U4 - 1 3AFY64556568
ACS800-U4 Type Code Sheet 150 - 600 HP, Drive module
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
J400 CDP 312R control panel (incl. 3 m control panel cable)
J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-U4 - 2 3AFY64556568
J410 RPMP-11 control panel mounting platform incl. 3 m panel connection cable (Without control panel)
J413
Filters
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E208 Common mode filter (Only for R7)
Resistor braking
D150
Pedestal
0H354 No pedestal
Documentation language
0R715 No documentation
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P901 Coated boards
P904 Extended warranty
Braking chopper (Including output busbar kit for braking chopper and DC unless +0H354 has been
selected)
RPMP-21 control panel mounting platform ("pocket" model to be mounted inside
the enclosure without control panel)
+0R715: Module is delivered without manuals. This needs to be
P904 Extended warranty
ACS800-U4 - 2 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 7 Construction
Channel
1014 - Size
Frame Size R5 R6 R7 R8
400V 0075 0100 0120 0135 0260 0320 0400
0165 0205 0440 0490
500V 0105 0120 0140 0165 0320 0400 0440
0205 0255 0490 0550 0610
690V 0070 0100 0120 0320 0400 0440
0145 0175 0205 0260 0490 0550 0610
1516 - Voltage Rating
3 = 400 V 5 = 500 V 7=690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
07 = Cabinet built, IP21 (UL type1), Main switch fuse with aR fuses, 230 VAC
control voltage, Control Panel CDP312R, No EMC filter, Standard software,
Bottom entry and exit of cables, Cable lead through entry, Boards without
coating, One set of default language documents
L516 available only with PMSM
Distribution Channels
!ndustry Segments Application Areas
ACS800-07(R5-R8) - 1 3AFY64556568
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter Requires DDCS communication
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
Communication board has always
one dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
N-type fieldbus adapters require DDCS
Communication board.
Add L503 or L509 to code
L516 available only with PMSM
control
I/O extension adapter
(requires DDCS
communication), adds three
slots for I/O extension and
Pulse encoder. Check
compatibility with different
application softwares.
ACS800-07(R5-R8) - 1 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-07(R5-R8) - 2 3AFY64556568
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Construction
C121 Marine construction
C129 UL listed
C134 CSA approved
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, frame R5 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network, not for frame R5
E205 Du/dt limitation by choke
E208 Common mode filter
E206 Sine output filter
C134 Includes US/CSA type main switch fuse, Bottom entry and exit,
115VAC control voltage, US Cable conduit entry, all components UL/CSA
listed/recognized, max. supply voltage 600 V
Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134
E206 is not available for R5 and R6 except 0135-3, 0205-3, 0165-5, 0255-5,
0145-7 and 0175-7. Not available for 0260-7, 0490-7, 0610-7 or with C121,
C129 or E205. Available output current reduced for some types
Not for 690V, adds width by 200 mm for R7, 400 mm for R8
C129 includes US type main switch fuse, Top entry and exit,115VAC control
voltage, US Cable conduit entry, all components UL listed/recognized, max.
supply voltage 600 V
E208 is not available for R5 and R6 except 0135-3, 0165-3, 0205-
3, 0165-5, 0205-5, 0255-5, 0145-7, 0175-7 and 0205-7
ACS800-07(R5-R8) - 2 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Resistor braking
D150 Braking chopper
D151 Braking resistor
Line fuses
F251 gG line fuses
Line options
F250 Line contactor
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H356 DC cable connection busbars
H358 Cable conduit entry (US & UK version) (Included with C129 or C134)
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)
Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1
Braking resistor is not available as IP54, IP54R, or with C121, C129 or C134.
Available output current reduced for some types
Replaces standard aR fuses, not available with C129
or C134
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
ACS800-07(R5-R8) - 3 3AFY64556568
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-07(R5-R8) - 3 3AFY64556568
ACS800-07 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Starter for auxiliary Motor fan
M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc)
M605 10...16 A (1 pc)
Safety features
Q950 Prevention of unexpected start up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Specialities
P901 Coated boards
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
M604 and M605 are not available for R5 or R6 except 0165-3,
0205-3, 0205-5, 0255-5, 0175-7 and 0205-7
Q951 and Q952 require line
contactor F250
* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or
Permanent Magnet Control Std application (add +L501 to code)
ACS800-07(R5-R8) - 4 3AFY64556568
P913 Special colour (Described in Technical appendix)
ACS800-07(R5-R8) - 4 3AFY64556568
ACS800-U7 Type Code Sheet 150 - 600 HP, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - U 7 Construction
Channel
1014 - Size
Frame Size R6 R7 R8
0270 0300
500V 0100 0120 0140 0320 0400 0440
0165 0205 0490 0550 0610
690V
(600V) 0070 0100 0120 0320 0400 0440
0145 0175 0205 0260 0490 0550 0610
1516 - Voltage Rating
5 = 500 V 7=690 V (600V)
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
U7 = Cabinet built(USA), UL type1 (IP21), US type main switch fuse, 115VAC control
voltage, Control panel CDP312R, No EMC filter, Standard software (US), Top entry
and exit of cables, Cable conduit entry, Common mode filter in R8, One set of default
language documents
L516 available only with PMSM
control
Distribution Channels
!ndustry Segments Application Areas
ACS800-U7(R6-R8) - 1 3AFY64556568
L516 Resolver interface RRIA-01
L503 DDCS Communication 3 RDCO-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505)
L515 I/O extension adapter Requires DDCS communication
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01
N-type fieldbus adapters require
DDCS Communication board.
Add L503 or L509 to code
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
Communication board has always
one dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
I/O extension adapter (requires DDCS
communication), adds three slots for
I/O extension and Pulse encoder.
Check compatibility with different
application softwares.
control
ACS800-U7(R6-R8) - 1 3AFY64556568
ACS800-U7 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B054 IP42 (UL type 1)
Master follower includes optic fibres, requires DDCS
communication (add L503, L509 or L508 to code)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
ACS800-U7(R6-R8) - 2 3AFY64556568
B055 IP54 (UL type 12)
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E210 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed/Unearthed Network
E205 Du/dt limitation by choke
E208 Common mode filter
Resistor braking
D150 Braking chopper
Line options
F250 Line contactor
Cabling
H350 Bottom entry
H352 Bottom exit
H356 DC cable connection busbars
H357 Cable lead through entry (European)
Control voltage
G320 230 VAC Control Voltage
Not for 690V, adds width by 200 mm for R7, 400 mm for R8
Standard in R8, not available for R5 and R6 except 0135-3, 0165-3, 0205-
3, 0165-5, 0205-5, 0255-5, 0145-7, 0175-7 and 0205-7
ACS800-U7(R6-R8) - 2 3AFY64556568
ACS800-U7 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Cabinet options
G300 Cabinet heater (External supply)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230 VAC or 115 VAC (UPS)
G330 Halogen free wiring and materials
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-U7(R6-R8) - 3 3AFY64556568
Starter for auxiliary Motor fan
M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc)
M605 10...16 A (1 pc)
Safety features
Q950 Prevention of unexpected start up Not with Q968,Q963,Q964
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker Not with Q950
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *) Not with Q950
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Specialities
P901 Coated boards
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
M604 and M605 are not available for R5 or R6 except 0165-3, 0205
3, 0205-5, 0255-5, 0175-7 and 0205-7
* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge- or
Permanent Magnet Control Std application (add +L501 to code)
Q951 and Q952 require
line contactor (add F250 to
ACS800-U7(R6-R8) - 3 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 0 7 Construction
Channel
1014 - Size
Frame Size 2xR8i 3xR8i 4xR8i 5xR8i 6xR8i
1xD4 2xD4 2xD4 3xD4 2xD4 3xD4 3xD4 3xD4 4xD4
400V 0610 0770 1230 1540 1850
0870
1030
500V 0760 0910 1540 1820 2310
1090
1210
690V 0750 1160 1500 2120 2320 2900 3190 3490
0870 1740
1060
1516 - Voltage Rating
3 = 400 V 5 = 500 V 7=690 V
+V992 Equipped with the new DSU module
Option codes
07 = Cabinet built, IP21 (UL type1), Main Switch, 230 VAC control voltage, Control
panel CDP312R, DDCS communication RDCO-03, EMC/RFI-filter 2nd Environment,
Du/dt limitation by choke, Common mode filter, Standard software, Bottom entry and
exit of cables, Cable lead through entry, Coated boards, One set of default language
documents
Distribution Channels
!ndustry Segments Application Areas
ACS800-07(nxR8i) - 1 3AFY64556568
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
I/O extension adapter Requires DDCS communication
L515 I/O extension adapter Requires DDCS communication
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
N-type Fieldbus adapters require DDCS
Communication board.
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for
I/O, the other only for motor
temp. measurement
Communication board has
always one dedicated slot.
Modbus adapter can be used
L516 available only with PMSM
RDCO-02 and RDCO-01 will
replace standard RDCO-03
I/O extension adapter adds three
slots for I/O extension and Pulse
encoder. Check compatibility with
different application softwares.
K456 AF100 adapter NAFA-01
Communication board.
ACS800-07(nxR8i) - 1 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N654 Spinning control
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
Software compatibility with different option modules must be checked from ACS800 software
compatibility document (doc no. 3AFE64638211) in ABB Library
Master follower includes optic fibres, requires DDCS
communication (add L509 or L508 to code)
ACS800-07(nxR8i) - 2 3AFY64556568
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Construction
C121 Marine construction
C129 UL listed
C134 CSA approved
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E206 Sine output filter
Resistor braking (standard option only for 2xR8i)
D150 Braking chopper
D151 Braking resistor
Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134
C134 includes 115VAC control voltage, Bottom entry and exit, US Cable
conduit entry, all components UL/CSA listed/recognized, max. supply voltage
600 V
EMC filter only for 6-pulse 0610-3 and 0760-5, requires Load
switch, Line fuses+additional field. Add F253 and F260 to
code
Braking resistor is not available as IP54, IP54R, or with C129 or C134.
Marine construction C121 available only for 500V and 690V.
Available output current reduced for some types
Sine filter is not available with
C129 includes aR line fuses and Load switch, Top entry and exit, 115VAC
control voltage, US Cable conduit entry, all components UL
listed/recognized, max. supply voltage 600 V. 3xD4 and 4xD4 require 12-
pulse operation A004 or Air circuit breaker F255
ACS800-07(nxR8i) - 2 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Line options
F250 Line contactor
Line options, not available with C129 (UL listed)
F253+F260 aR Line fuses and Load switch, 6-pulse operation
A004+F253+F260 aR Line fuses and Load switch, 12-pulse operation
F255+F260 Air circuit breaker, aR Line fuses, 6-pulse operation
F259 Earthing switch (only with F253 or F255, not available with C129/C134)
Line options available only with UL C129 (one of these required always with 3xD4 and 4xD4)
A004 12-pulse operation, includes two fields
F255 Air circuit breaker, 6-pulse operation
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H358 Cable conduit entry (US & UK version) (Included with C129 or C134)
H359 Common motor terminal cubicle
F250 and F255 are alternative options
Air circuit breaker is alternative to Load switch F253, not available with 1xD4.
Load switches inside DSU modules are removed
F253 includes additional field with input terminals. Load switches inside DSU modules are removed
Limitation with CSA C134: 6-pulse not available with 3xD4 or 4xD4
IP54 or IP54R with top entry require Load switch F253 or Air
circuit breaker F255. Dimensions may increase.
Air circuit breaker replaces Load switch, not available with 1xD4.
ACS800-07(nxR8i) - 3 3AFY64556568
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)
Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G317 Busbar Supply Conductors (6-pulse only, requires load switch F253 or air circuit breaker F255)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-07(nxR8i) - 3 3AFY64556568
ACS800-07 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
M602 2,5...4 A (1,2 or 4 pcs)
M603 4...6,3 A (1,2 or 4 pcs)
M604 6,3...10 A (1,2 or 4 pcs)
M605 10...16 A (1 or 2 pcs)
M606 1725 A (1 pc)
Safety features
Q950 Prevention of unexpected start up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q951 and Q952 require
line contactor F250 or
breaker F255
ACS800-07(nxR8i) - 4 3AFY64556568
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q959 Red tripping push button for external breaker
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
* Category 1 E-stop reserves one RDIO module with Standard-, Master follower-,
Centrifuge- or Permanent Magnet Control Std application (add +L501 to code)
line contactor F250 or
breaker F255
ACS800-07(nxR8i) - 4 3AFY64556568
ACS800-11 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 1 1 Construction
Channel
1014 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060
400V 0016 0020 0025 0060 0070
0030 0040 0050 0100
500V 0020 0025 0030 0070 0100
0040 0050 0060 0120
690V 0060 0070
0100
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
11 = Wall mounted regenerative drive, IP21, With control panel CDP312R,
RDCO-03, No EMC filter, Standard software, Cable lead through entry,
Boards with coating, One set of default language documents.
!ndustry Segments Application Areas
Distribution Channels
ACS800-11 - 1 3AFY64556568
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
L516 available only with Motion control and
PMSM control
1 or 2 Digital extensions
1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
With motion control sw it is possible to
have 1 or 2 pulse encoder/resolver
interfaces
Communication board has always one
dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
ACS800-11 - 1 3AFY64556568
ACS800-11 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N668 Traverse control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
ACS800-11 - 2 3AFY64556568
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Cabling
H358 Cable conduit entry (US & UK version)
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P904 Extended warranty
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
E202 not available for 690V units
P904 Extended warranty
ACS800-11 - 2 3AFY64556568
ACS800-U11 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - U 1 1 Construction
Channel
1014 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060
500V 0020 0025 0030 0070 0100
0040 0050 0060 0120
690V 0060 0070
(600V) 0100
1516 - Voltage Rating
2 = 230 V 5 = 500 V 7 = 690 V (600V)
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
U11 = Wall mounted regenerative drive (USA), IP21, With control panel
CDP312R, RDCO-03, No EMC filter, Standard software (US), Cable conduit
entry, Boards with coating, One set of default language documents.
!ndustry Segments Application Areas
Distribution Channels
ACS800-U11 - 1 3AFY64556568
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L517 Pulse encoder interface TTL RTAC-03
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
L516 available only with Motion control and
PMSM control
1 or 2 Digital extensions
1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
With motion control sw it is possible to
have 1 or 2 pulse encoder/resolver
interfaces
Communication board has always one
dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
ACS800-U11 - 1 3AFY64556568
ACS800-U11 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Filters
Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library..
ACS800-U11 - 2 3AFY64556568
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Cabling
H357 Cable lead through entry (European)
Safety features
Q950 Prevention of unexpected start-up Not with Q967
Q967 Safe torque off STO, without safety relay Not with Q950
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P904 Extended warranty
E202 not available for 690V units
Separate gate driver power supply board (AGPS or ASTO) and connection wires included in the converter
package. Does not include e.g. safety relay.
ACS800-U11 - 2 3AFY64556568
ACS800-31 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 3 1 Construction
Channel
1014 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060
400V 0016 0020 0025 0060 0070
0030 0040 0050 0100
500V 0020 0025 0030 0070 0100
0040 0050 0060 0120
690V 0060 0070
0100
1516 - Voltage Rating
2 = 230 V 3 = 400 V 5 = 500 V 7 = 690 V
Option codes
31 = Wall mounted low harmonic drive, IP21, With control panel CDP312R,
RDCO-03, No EMC filter, Standard software, Cable lead through entry,
Boards with coating, One set of default language documents.
!ndustry Segments Application Areas
Distribution Channels
ACS800-31 - 1 3AFY64556568
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
Communication board has always
one dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
L516 available only with PMSM
control
ACS800-31 - 1 3AFY64556568
ACS800-31 Type Code Sheet 7.5 - 110 kW, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N685 Motion control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Filters
Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
ACS800-31 - 2 3AFY64556568
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Cabling
H358 Cable conduit entry (US & UK version)
Safety features
Q967 Safe torque off STO, without safety relay
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
P904 Extended warranty
E202 not available for 690V units
Separate gate driver power supply board (ASTO) and connection wires included in the converter package.
Does not include e.g. safety relay.
ACS800-31 - 2 3AFY64556568
ACS800-U31 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - U 3 1 Construction
Channel
1014 - Size
Frame Size R5 Frame Size R6
230V 0011 0016 0020 0040 0050
0025 0030 0060
500V 0020 0025 0030 0070 0100
0040 0050 0060 0120
690V 0060 0070
(600V) 0100
1516 - Voltage Rating
2 = 230 V 5 = 500 V 7 = 690 V (600V)
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters
L500 Analogue I/O extension RAIO-01
U31 = Wall mounted low harmonic drive (USA), IP21, With control panel
CDP312R, RDCO-03, No EMC filter, Standard software (US), Cable conduit
entry, Boards with coating, One set of default language documents.
!ndustry Segments Application Areas
Distribution Channels
ACS800-U31 - 1 3AFY64556568
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
1 or 2 Digital extensions
1or 2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
Communication board has always
one dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
L516 available only with PMSM
control
ACS800-U31 - 1 3AFY64556568
ACS800-U31 Type Code Sheet 10 - 125 HP, Wall Mounted
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Control panel
0J400 No control panel
Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
ACS800-U31 - 2 3AFY64556568
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
Cabling
H357 Cable lead through entry (European)
Safety features
Q967 Safe torque off STO, without safety relay
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Specialities
E202 not available for 690V units
Separate gate driver power supply board (ASTO) and connection wires included in the converter package.
Does not include e.g. safety relay.
ACS800-U31 - 2 3AFY64556568
P904 Extended warranty
ACS800-U31 - 3 3AFY64556568 ACS800-U31 - 3 3AFY64556568
ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 1 7 Construction
Channel
1014 - Size
Frame Size R6 R7i R8i
400V 0060 0070 0140 0170 0210 0260 0320
0100 0390 0490
500V 0070 0100 0170 0210 0260 0320 0400
0120 0460 0510 0580
690V 0060 0070 0160 0200 0260 0320 0400
0100 0440 0540
1516 - Voltage Rating
3 = 400 V 5 = 500 V 7=690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
17 = Cabinet built regenerative drive, IP21 (UL type1), Main switch fuse with
aR fuses, Line contactor (option for frame R6), 230 VAC control voltage,
RDCO-03, Control Panel CDP312R, EMC 2nd Environment (R6 no EMC
filter), Du/dt limitation by choke in 690V R8i, Common mode filter (not for R6),
Standard software, Bottom entry and exit of cables, Cable lead through entry,
Coated boards, One set of default language documents
Standard control supports
Distribution Channels
!ndustry Segments Application Areas
ACS800-17 (R6-R8i) - 1 3AFY64556568
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for
I/O, the other only for motor
temp. measurement
Communication board has
always one dedicated slot.
Modbus adapter can be used
with other Fieldbus adapter
I/O extension adapter adds three
slots for I/O extension and Pulse
encoder. Check compatibility
with different control softwares.
N-type fieldbus adapters require DDCS
Communication board.
RDCO-03 included by default, L509 is
optional
L516 available only with PMSM control
ACS800-17 (R6-R8i) - 1 3AFY64556568
ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive
materials, requires marking of conductors (G338-G342)
Software compatibility with different option modules must be checked from ACS800 software compatibility
(doc no. 3AFE64638211) in ABB Library.
ACS800-17 (R6-R8i) - 2 3AFY64556568
C121 Marine construction
C129 UL listed
C134 CSA approved
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network, not available for 690V
E205 Du/dt limitation by choke (included in 690V R8i)
E206 Sine output filter
Line options
F250 Line contactor (only for R6, included in other types)
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H356 DC cable connection busbars
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
Reinforced mechanics and fastening, door handels, self extinctive
materials, requires marking of conductors (G338-G342)
Not available with C129 or C134
Not available for R6 or with C121 or C129. Available output current reduced
for some types
E202 in frames R7i and R8i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).
C129 includes: US type main switch fuse, Supply frequency 60 Hz, Top
entry and exit,115VAC control voltage, US Cable conduit entry, all
components UL listed/recognized, max. supply voltage 600 V.
C134 Includes: US/CSA type main switch fuse, Supply frequency 60 Hz,
115VAC control voltage, US Cable conduit entry, all components UL/CSA
listed/recognized, max. supply voltage 600 V
E205 in frame R7i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).
H365 Cable conduit entry (US & UK version), brass 6 mm
H359 Common motor terminal cubicle Only with E202 in R7i/R8i or with E205 in R7i
ACS800-17 (R6-R8i) - 2 3AFY64556568
ACS800-17 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)
Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-17 (R6-R8i) - 3 3AFY64556568
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc) (not for R6)
M605 10...16 A (1 pc) (not for R6)
Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
Category 1 e-stop reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or
Permanent Magnet Control Std applicatrion (add +L501 to code)
Q951 and Q952 require
contactor F250 for R6
ACS800-17 (R6-R8i) - 3 3AFY64556568
ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 1 7 Construction
Channel
1014 - Size
Frame Size 2xR8i 3xR8i 4xR8i 6/5xR8i 6xR8i
400V 0640 0770 1070 1370 1810
0960
500V 0780 0870 1330 1640 2160
1140
690V 0790 0870 1330 1510 1980 2780 2940
1050
1516 - Voltage Rating
3 = 400 V 5 = 500 V 7=690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
17 = Cabinet built regenerative drive, IP21 (UL type1), Air circuit breaker, aR fuses, 230
VAC control voltage, Control panel CDP312R, RDCO-03, EMC 2nd Environment, Du/dt
limitation by choke, Common mode filter, Standard software, Bottom entry and exit of
cables, Cable lead through entry, Coated boards, One set of default language
documents
Distribution Channels
!ndustry Segments Application Areas
ACS800-17 (nxR8i) - 1 3AFY64556568
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for
I/O, the other only for motor temp.
measurement
Communication board has always
one dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
I/O extension adapter adds three
slots for I/O extension and Pulse
encoder. Check compatibility with
different application softwares.
N-type fieldbus adapters require DDCS
Communication board.
RDCO-03 included by default, L509 is
optional
L516 available only with PMSM control
Distribution Channels
!ndustry Segments Application Areas
ACS800-17 (nxR8i) - 1 3AFY64556568
ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Software compatibility with different option modules must be checked from ACS800 software compatibility (doc
no. 3AFE64638211) in ABB Library.
ACS800-17 (nxR8i) - 2 3AFY64556568
B059 IP54R
Construction
C121 Marine construction
C129 UL listed
C134 CSA approved
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E206 Sine output filter
Line options
F259
Earthing switch (not available with C129)
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
H359 Common motor terminal cubicle
Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134
C129 includes: Top entry and exit, Supply frequency 60 Hz, 115VAC control
voltage, US Cable conduit entry, all components UL/CSA listed/recognized,
max. supply voltage 600 V
EMC filter only for 0640-3, 0770-3, 0780-5
and 0870-5
Sine filter is not available with
C121 or C129.
C134 includes: 115VAC control voltage, US Cable conduit entry, Supply
frequency 60Hz, all components UL/CSA listed/recognized, max. supply
voltage 600 V
ACS800-17 (nxR8i) - 2 3AFY64556568
ACS800-17 Type Code Sheet 500 - 2500 kW, Cabinet built
Updated on 12 October 2011
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)
Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G317 Busbar Supply Conductors
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-17 (nxR8i) - 3 3AFY64556568
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
M602 2,5...4 A (1,2 or 4 pcs)
M603 4...6,3 A (1,2 or 4 pcs)
M604 6,3...10 A (1,2 or 4 pcs)
M605 10...16 A (1 or 2 pcs)
M606 1725 A (1 pc)
Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker*)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent Magnet
Control Std applicatrion (add +L501 to code)
P913 Special colour (Described in Technical appendix)
ACS800-17 (nxR8i) - 3 3AFY64556568
ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 3 7 Construction
Channel
1014 - Size
Frame Size R6 R7i R8i
400V 0060 0070 0140 0170 0210 0260 0320
0100 0390 0510
500V 0070 0100 0170 0210 0260 0320 0400
0120 0460 0510 0610
690V 0060 0070 0170 0210 0260 0320 0400
0100 0440 0540
1516 - Voltage Rating
3 = 400 V 5 = 500 V 7=690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
L500 Analogue I/O extension RAIO-01
37 = Cabinet built low harmonic drive, IP21 (UL type1), Main switch fuse with
aR fuses, Line contactor (option for frame R6), 230 VAC control voltage,
RDCO-03, Control Panel CDP312R, EMC 2nd Environment (R6 no EMC
filter), Du/dt limitation by choke in 690V R8i, Common mode filter (not for R6),
Standard software, Bottom entry and exit of cables, Cable lead through entry,
Coated boards, One set of default language documents
Standard control supports
3 Digital extensions and
Distribution Channels
!ndustry Segments Application Areas
ACS800-37 (R6-R8i) - 1 3AFY64556568
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for
I/O, the other only for motor
temp. measurement
Communication board has
always one dedicated slot.
Modbus adapter can be used
with other Fieldbus adapter
I/O extension adapter adds
three slots for I/O extension and
Pulse encoder. Check
compatibility with different
application softwares.
N-type fieldbus adapters require
DDCS Communication board.
RDCO-03 included by default, L509
is optional
L516 available only with PMSM control
ACS800-37 (R6-R8i) - 1 3AFY64556568
ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter Control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Construction
C121 Marine construction Reinforced mechanics and fastening, door handels, self extinctive
materials, requires marking of conductors (G338-G342)
Not available with C129 or C134
Software compatibility with different option modules must be checked
from ACS800 software compatibility (doc no. 3AFE64638211) in ABB
Library.
ACS800-37 (R6-R8i) - 2 3AFY64556568
C129 UL listed
C134 CSA approved
Filters
E200 EMC/RFI-filter, Cat. C3, 2nd Env., Earthed Network, R6 only
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network, not available for 690V
E205 Du/dt limitation by choke (included in 690V R8i)
E206 Sine output filter
Resistor braking
D150 Braking chopper
D151 Braking resistor
Line options
F250 Line contactor (only for R6, included in other types)
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H356 DC cable connection busbars
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
Not available for R6, or with C121 , C129, D150 or D151. Available output
current reduced for some types
Braking resistor is not available as IP54, IP54R, or with C121 , C129 or
E206. Available output current reduced for some types
C129 includes: US type main switch fuse, Supply frequency 60 Hz, Top
entry and exit,115VAC control voltage, US Cable conduit entry, all
C134 Includes: US/CSA type main switch fuse, Supply frequency 60 Hz
115VAC control voltage, US Cable conduit entry, all components UL/CSA
materials, requires marking of conductors (G338-G342)
Not available with C129 or C134
E202 in frames R7i and R8i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).
E205 in frame R7i requires a common motor terminal cubicle, adds width by 300mm
(insert H359 to type code).
H359 Common motor terminal cubicle Only with E202 in R7i/R8i or with E205 in R7i
ACS800-37 (R6-R8i) - 2 3AFY64556568
ACS800-37 Type Code Sheet 55 - 500 kW, Cabinet built
Updated on 12 October 2011
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)
Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-37 (R6-R8i) - 3 3AFY64556568
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
M600 1...1,6 A (1 pc)
M601 1,6...2,5 A (1 pc)
M602 2,5...4 A (1 pc)
M603 4...6,3 A (1 pc)
M604 6,3...10 A (1 pc) (not for R6)
M605 10...16 A (1 pc) (not for R6)
Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or Permanent
Magnet Control Std applicatrion (add +L501 to code)
Q951 and Q952 require
contactor F250 for R6
ACS800-37 (R6-R8i) - 3 3AFY64556568
ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
16 A C S 8 0 0 Product Series Industry Application
79 - 3 7 Construction
Channel
1014 - Size
Frame Size 2xR8i 3xR8i 4xR8i 6/5xR8i 6xR8i
400V 0640 0770 1070 1430 1810
0960
500V 0780 0870 1330 1820 2200
1160
690V 0790 0870 1330 1510 2320 2780 3310
1160
1516 - Voltage Rating
3 = 400 V 5 = 500 V 7=690 V
Option codes
I/O options 2 slots available for I/O options or Fieldbus adapters as standard
37 = Cabinet built low harmonic drive, IP21 (UL type1), Air circuit breaker, aR fuses, 230
VAC control voltage, Control panel CDP312R, RDCO-03, EMC 2nd Environment, Du/dt
limitation by choke, Common mode filter, Standard software, Bottom entry and exit of
cables, Cable lead through entry, Coated boards, One set of default language
documents
Distribution Channels
!ndustry Segments Application Areas
ACS800-37 (nxR8i) - 1 3AFY64556568
L500 Analogue I/O extension RAIO-01
L501 Digital I/O extension RDIO-01
L502 Pulse encoder interface RTAC-01
L516 Resolver interface RRIA-01
L509 DDCS Communication 2 RDCO-02
L508 DDCS Communication 1 RDCO-01
L504 Additional I/O-Terminal Block
L505 Thermistor Relay (1 or 2 pcs) (Not with L506, L513 or L514)
L506 Pt100 Relay (3, 5 or 8 pcs) (Not with L505, L513 or L514)
L513 ATEX Certified thermal protection with PTC (1 or 2 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L514)
L514 ATEX Certified thermal protection with Pt100 relay (3, 5 or 8 pcs)
(requires ATEX safety function, add Q971 to code, not with L505, L506 or L513)
L515 I/O extension adapter
Fieldbus 2 slots available for I/O options or Fieldbus adapters
K451 DeviceNet adapter RDNA-01
K452 LONWorks adapter RLON-01
K454 Profibus-DP adapter RPBA-01
K457 CANOpen adapter RCAN-01
K458 Modbus adapter RMBA-01
K462 ControlNet adapter RCNA-01
K466 Ethernet adapter(EIP,MB/TCP) RETA-01
K467 Ethernet adapter(Profinet IO, MB/TCP) RETA-02
K453 Interbus-S adapter NIBA-01
K456 AF100 adapter NAFA-01
Standard control supports
3 Digital extensions and
2 Analogue extensions, one for I/O,
the other only for motor temp.
measurement
Communication board has always
one dedicated slot.
Modbus adapter can be used with
other Fieldbus adapter
I/O extension adapter adds three
slots for I/O extension and Pulse
encoder. Check compatibility with
different application softwares.
N-type fieldbus adapters require
DDCS Communication board.
RDCO-03 included by default, L509
is optional
L516 available only with PMSM control
Distribution Channels
!ndustry Segments Application Areas
ACS800-37 (nxR8i) - 1 3AFY64556568
ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Program
N687 Pump control
N651 Master/follower control
N652 Crane drive control
N653 Application base control Available only for Drives Engineering Centers
N655 PCP and ESP control
N660 Inline control
N661 Winder control
N669 Centrifuge control Decanter control requires DDCS communication + optic fibres
N671 System control
N675 Rod pump control
N677 PMSM control - system interface (for low speed-high torque motors)
N679 PMSM control - standard interface (for low speed-high torque motors)
N682 Multiblock control
N697 Crane control
N698 Winch control
N678 Test bench control
Protection class
B053 IP22 (UL type 1)
B054 IP42 (UL type 1)
B055 IP54 (UL type 12)
B059 IP54R
Program compatibility with different option modules must be checked from ACS800 software compatibility (doc
no. 3AFE64638211) in ABB Library.
ACS800-37 (nxR8i) - 2 3AFY64556568
B059 IP54R
Construction
C121 Marine construction
C129 UL listed
C134 CSA approved
Filters
E202 EMC/RFI-filter, Cat. C2, 1st Env., Earthed Network
E206 Sine output filter
Resistor braking (standard option only for 2xR8i)
D150 Braking chopper
D151 Braking resistor
Line options
F259
Earthing switch (not available with C129)
Cabling
H351 Top entry (included with C129)
H353 Top exit (included with C129)
H350 Bottom entry (only with C129)
H352 Bottom exit (only with C129)
H358 Cable conduit entry (US & UK version), steel 3 mm (Included with C129 or C134)
H365 Cable conduit entry (US & UK version), brass 6 mm
Reinforced mechanics and fastening, door handels, self extinctive materials,
requires marking of conductors (G338-G342)
Not available with C129 or C134
EMC filter only for 0640-3, 0770-3, 0780-5
and 0870-5
Braking resistor is not available as IP54, IP54R, with C129 or E206. Marine
construction C121 available only for 500V and 690V.
Available output current reduced for some types
Sine filter is not available with
c121 , c129, u150 ot u151.
C129 includes: Top entry and exit,115VAC control voltage, Supply frequency
60 Hz, US Cable conduit entry, all components UL/CSA listed/recognized,
max. supply voltage 600 V
C134 includes: 115VAC control voltage, US Cable conduit entry, Supply
frequency 60Hz, all components UL/CSA listed/recognized, max. supply
voltage 600 V
H359 Common motor terminal cubicle
ACS800-37 (nxR8i) - 2 3AFY64556568
ACS800-37 Type Code Sheet 500 - 2800 kW, Cabinet built
Updated on 12 October 2011
Control voltage
G304 115 VAC Control Voltage (Included with C129 or C134)
Cabinet options
G300 Cabinet heater (External supply) (Not available with C134)
G313 Output for Motor heater (External supply)
G307 Terminals for External Control Voltage 230VAC or 115VAC (UPS)
G317 Busbar Supply Conductors
G330 Halogen free wiring and materials (Not available with C129 or C134)
G338 Wire marking class A1
G339 Wire marking class A2
G340 Wire marking class A3
G341 Wire marking class B1
G342 Wire marking class C1
Documentation language
R700 English
R701 German Delivered set may include manuals in English
R702 Italian Delivered set may include manuals in English
R703 Dutch Delivered set may include manuals in English
R704 Danish Delivered set may include manuals in English
R705 Swedish Delivered set may include manuals in English
R706 Finnish Delivered set may include manuals in English
R707 French Delivered set may include manuals in English
Class A1, equipment pin numbers printed on conductors, conductors
to terminal blocks not marked
Class A2, equipment and terminal block pin numbers printed on
conductors
Class A3, like A2 but marking by rings
Class B1, equipment and terminal block pin numbers and equipment
Ids marked by rings
Class C1, like B1 but remote end address is also marked
ACS800-37 (nxR8i) - 3 3AFY64556568
R707 French Delivered set may include manuals in English
R708 Spanish Delivered set may include manuals in English
R709 Portuguese (in Portugal) Delivered set may include manuals in English
R711 Russian Delivered set may include manuals in English
Starter for auxiliary Motor fan
M602 2,5...4 A (1,2 or 4 pcs)
M603 4...6,3 A (1,2 or 4 pcs)
M604 6,3...10 A (1,2 or 4 pcs)
M605 10...16 A (1 or 2 pcs)
M606 1725 A (1 pc)
Safety features
Q950 Prevention of unexpected start-up Not with Q968,Q963,Q964, Q971
Q951 Emergency Stop, Category 0 with opening main contactor/breaker
Q952 Emergency Stop, Category 1 with opening main contactor/breaker *)
Q963 Emergency Stop, Category 0 without opening main contactor/breaker
Q964 Emergency Stop, Category 1 without opening main contactor/breaker *)
Q968 Safe torque off STO, with safety relay Not with Q950
Q954 Earth Fault Monitoring, Unearthed Mains
Q971 ATEX certified safety function Only with L513 and L514, not with Q950
Specialities
P902 Customised (Described in Technical appendix)
P904 Extended warranty
P913 Special colour (Described in Technical appendix)
* Category 1 reserves one RDIO module with Standard-, Master follower-, Centrifuge-, or
Permanent Magnet Control Std applicatrion (add +L501 to code)
ACS800-37 (nxR8i) - 3 3AFY64556568
ABB Oy, Drives Technical Appendix for ACS800-x7
Revision:
ABB Company: Date: Page:
Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
eMail: Customer ref:
ACS800-07/-17/-37 Non-Standard Options in ACS 800 Price List
All options below needs also +P902 option
No engineering needed only standard as build drawings with customer specific drawing title blocks
(specify above project title, end customer and customer ref) no additional engineering
Document approval not needed, send them just for information before starting the production
Supply freq. for options 60Hz (default 50Hz) Signal lamps (specify colours pcs:
and function)
Power for RMIO board from internal Additional relays (specify type pcs:
230 VAC (Only for ACS800-07, R6-R8) and function)
Ammeter AI/O galvanic isolation for mA signal (1-4 pcs)
Voltmeter
Running hour meter Customer specific cable lead through (gland) plate
(specify below)
+P913 Special colour RAL Empty cabinet (specify on separate page)
NAMUR I/O, requires also +H366 Internal parallel connection busbars for 2xR8i and 3xR8i
+F250+Q951+L501+K454+P902
+C164 Plinth for the cabinet, height: 100mm
+C130 Air outlet channel (IPxxR) 200mm
+D150 Braking chopper (NBRA-6X9) (3-6xR8i)
+C128 Air inlet through bottom +D151 Braking resistor (SAFUR) (3-6xR8i)
3 phase braking chopper (ACS800-607)
Bypass, specify on page "Bypass" (specify the braking power)
+Q965 SLS with encoder
+Q966 SLS without encoder
Design by the old reference project. FIDRI No.: or Purchace No.:
Detailed description of desired function:
Other information
Customer/Local ABB delivers components to FIDRI
and sends the Data Sheets of the components with Technical Appendix. (min. 9weeks before loading date)
Customer/Local ABB delivers predesign documentation
Special door labels (specify using separate appendix)
Preliminary documentation required: Delivery time must be agreed with FIDRI Area Manager
Dimension drawings By Lotus Notes
Control circuit diagrams
Delivery of final documentation By Lotus Notes
Company
Attention Phone
Country e-mail
Address TechnApp - 1 3AFY64556568
ABB Oy, Drives Technical Appendix for ACS800-x7 with Bypass
Revision:
ABB Company: Date: Page:
Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
eMail: Customer ref:
ACS800-07/-17/-37 Engineered DOL Bypass
Please specify nominal motor power (P), full load current (FLC) in the direct on line (DOL) supply:
Nominal power: kW
Full load current: A
Network voltage: VAC
Options required also:
+G307 (Terminals for External Control Voltage)
+P902 (Customized)
Protections for the motor included in the SACE Tmax PR222MP as standard
Adjustable protection against overload, rotor block, short-circuit and missing phase or unbalanced
Ground leakage protection in earthed networks as an option (please select if required).
Ground leakage monitoring by sum current transformer and monitoring relay
Change over control
Manual Local
External
Automatic Synchronization
Please note:
Engineered DOL bypass not for +C129 (UL listed) ; +C134 (CSA approved) nor +E202 (EMC/RFI-filter)
Additional information:
ABB Oy, Drives Technical Appendix for ACS800-x7
Empty cabinets
ABB Company: Date: Page:
Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
Email:
Number of empty cabinets
Colour
RAL 7035 (std.) Special
Mounting
Mounted to the frequency converter Stand-alone
On the left side of the frequency converter
(front view)
On the right side of the frequency converter
(front view)
Enclosure
IP21 Normal door with air inlet openings
IP22 Normal door with control panel mounting platform
IP42 Blank door and roof & no air inlet openings
IP54 (no cooling fans)
IP54R (outlet connection to ventilation channel)
Cable lead through (for empty cabinet)
Standard cable lead through No need for cable lead through
(sealed roof and bottom)
Top Cable gland plate 6mm brass (undrilled)
Cable gland plate 3mm steel (undrilled)
Bottom Cable gland plate 3mm aluminium (undrilled)
Cabinet width
300mm 700 mm
400 mm 800 mm
600 mm 1000 mm
Assembly plates on both sides and on back as standard
Additional information:
TechnApp - 1 3AFY64556568
ABB Oy, Drives Technical Appendix for ACS800-x7
Labels
ABB Company: Date: Page:
Your ref: End Customer:
Contact Person: Project Title:
Phone / Fax: Application:
eMail:
Labels described in this specification are not included as standard only with option +P902.
Models A and B are factory preferred types. If location of labels is not specified, standard location will
be used. Specify location using the lay-out drawing.
Rivet mounting Customer delivers own door labels
Stick-on label Customer defined labels
Specify:
label size
Factory preferred types
character height
A Main reference label
size 140 x 33 mm characters per line
Char. height 20 mm
Max 5 characters
B Description label
size 140 x 33 mm
Char. height 6 mm
23 char. per line , max 3 lines
C Apparatus label
52 x 13 mm
Char. height 3,5 mm
17 char. per line, max 2 lines
Standard location is about 12 mm below the apparatus
Model pcs. Sign text Location
TechnApp - 1 3AFY64556568

You might also like