3/8 Injection Check Valve High Pressure Spring Installation For use with the PosiFlow Sensor. Provides the required 30PSI back pressure when there is little or no system pressure.
Valve Housing

Spacer Spring Valve Check O-Ring 3/8 Fitting Coupling Nut

O-Ring 3/8 NPT 1/2 NPT

SPRING REPLACEMENT: 1. Unscrew the valve housing from the fitting. 2. Remove the existing spring and replace with the new high pressure spring (P/N E90375). 3. If there is a spacer behind the spring, make sure it also gets reinstalled. CAUTION: Note orientation of the valve check/spring combination. The o-ring end of the valve check should go into the fitting and the spring should go toward the valve housing.

4. During reassembly, make sure that the o-ring between the valve housing and the fitting does not get pinched. Hand tightening these together should be sufficient, but using a wrench to get a snug fit may be necessary for sealing (1/8 turn max.). Contact your local distributor with any questions about the installation of the high pressure spring into your 3/8 injection check valve.

Five Boynton Road Hopping Brook Park Holliston, MA 01746 USA TEL: 508-429-1110 FAX: 508-429-7433 WEB: www.walchem.com E00096.B 10/2008