Cng trnh/Project : Nh my lp rp in t Maseco Hng mc/Service : M&E - Calculation sheet

Ngy/Date : 22/12/09 Reason for issue : Approval Concept; Tender; Approval; Construction; Boq; Information; Action; Comment; Revision S lng pht hnh/Number of copies Issued - a CD/Disk : - Bn in/Print paper : - Bn photo/Photo paper : - Khc/Others :

Danh sch pht hnh/Distribution List : - Khch hng/Client : - Kin trc/Architect : - T vn C-in/M&E Consultant : - Nh thu chnh/Main Contractor : - Khc/Others : 1./ Cc tiu chun tham chiu : Standards reference - TCVN 2622-1995 - TCVN 4513-1988 - TCVN 5760-1993 - TCVN 4317-1986 - TCVN 6305-1997 - TCVN 7336:2003 - NFPA 13 - TCVN 3890-2009 - V cc tiu chun khc ti a phng And other code at local 2./ Thng tin d n : Project description - Nh xng: Work shop S tng (tng ): Number floor Din tch xy dng (m2) : Area (m2) - Nh vn phng: Office S tng (tng ): Number floor Din tch xy dng (m2) : Area (m2) - Nh n: Canteen S tng (tng ): Number floor Din tch xy dng (m2) : Area (m2) - Nh ngh: Rest room S tng (tng ): Number floor Din tch xy dng (m2) : Area (m2) 3./ Tnh ton h thng cha chy Fire fighting calculation a> Nc d tr cho cha chy vch Water for hose reel fire fighting system - Lu lng nc cha chy bn ngoi, Water for outside hose reel fire fighting

: Phng chng chy cho nh v cng trnh - yu cu thit k : Fire protection of buidings design requirements : Cp nc bn trong tiu chun thit k : Internal water supply. Design standard : H thng cha chy - yu cu chung v thit k lp t v s dng : Fire - extinguishing system general requirement of project install and utilize : Nh kho nguyn tc c bn thit k : Stores Basic rules for designing : Phng chy cha chy - h thng sprinkler t ng : Fire protection - automatic sprinkler systems : Phng chy cha chy-H thng Sprinkler t ng - Yu cu thit k v lp t : Fire protection - automatic sprinkler systems - design requirements and install : Tiu chun cha chy quc t : National fire protection association : Phng tin phng chy v cha chy cho nh v cng trnh - trang b, b tr, kim tra, bo dng : Fire protection equipments for building and construction - Providing, installation, inspection, maintenance

2 4584

2 816

1 492

1 84.2

tnh cho 1 m chy. TCVN 2622-1995(2) mc 10.5 bng 13 one fire. TCVN 2622-1995 (2), item 10.5, table 13 Q1 = 10 (l/s) - Lu lng nc cha chy bn trong, 2 hng phun. TCVN 2622-1995(2) mc 10.14 bng 14 Water for inside hose reel fire fighting two fire. TCVN 2622-1995(2), item 10.14, table 14 Q2 =2x 2,5 = 5 (l/s)

- Th tch ca b cha nc d tr phi m bo lng nc dng trong 3 gi (TCVN 2622-1995(2) mc 10.27) Water for hose reel fire fighting system, 3 hours (TCVN 2622-1995(2), item 10.27) Qhr = (Q1 + Q2) x 3 gi x k = 179 m H s k = 1.1 coefficient k b> Nc d tr cho cha chy t ng Water for Sprinkler - Mt bao ph: Density of water cover - Din tch tnh ton: area calculation - Lng nc cha chy trong 1 gi l: Qsk= Water for Sprinkler one hour c> Nc dng cho cha chy vch v cha chy t ng: Water for Hose reel and Sprinker Q=(Qhr+Qsh)*k H s k = coefficient k - Chn th tch d tr cho cha chy: W = Water for hose reel fire fighting system d> Thng s bm cha chy Water fire fighting Pump - Lu lng bm : Flow of Pump Qp = (Qhr + Qsk) x = Vi : h s an ton = : coefficient Chn bm c lu lng, Q = Choose Flow of Pump

7.2 mm/pht 240 m2 104 m3

(TCVN 7336:2003, bng 2) (TCVN 7336:2003, bng 2) (TCVN 7336:2003, bng 2)

311 m3 1.1 315 m

181 m/h 1.15 185 m/h

- p lc t do u ming lng ca hng nc cha chy v tr cao xa nht phi m bo Pressure at top head of hose reel (highest anh far) ct nc c khng di 10(m) (TCVN 2622.mc 10.11) head > 10m (TCVN 2622. item 10.11) -> Cao hnh hc t bm n im cao nht ca vi cha chy: Level from Fire pump to Hose reel H1 = 7 m Ct p ht ca bm, H2 = 4 m Head of inlet Pump - Tng mt p trong ng ng t bm n im cao, xa nht ca cng trnh Loss head of pipes - Tn tht p lc do ma st bn trong ng ng theo cng thc Hazen Williams Friction loss of pipe follow Hazen Williams

P = 6.05 x

Q1.85 x106 C xd 4.87


1.85

P= Q= C= d=
120

Tn tht ma st n v (m/m) Frictional resistance (m/m) Lu lng trong ng (l/pht) Water Flow (l/min) Hng s loi ng Fiction loss coefficient ng knh trong ng (mm) Actual internal diameter (mm)

d.1> Trng hp 1: cha chy cun vi Case 1: Hose reel fire fighting - Tn tht p lc do ma st bn trong ng ng cp nc bng thp hay gang Xc nh theo bng 15(TCVN4513-6.14) v cng thc sau : Table 15 (TCVN 4513-6.14) and formula i= (m) tn tht p lc trong ng trn 1m chiu di Loss head for 1m pipes 2 A= bng 15 (l/s) sc cn n v ph thuc vo ng knh ng Table 15 coefficient of pipe q= 15 (l/s) lu lng nc tnh ton Water Flow (l/s)

i A.q

Loi ng ng size of pipe ng DN150 Pipe DN150 ng DN50 Pipe DN50 Co DN150 Elbow DN150 T DN150 Tee DN150 Van DN150 Valve DN150

Khi lng (m, ci) Quantity (m, ea) 334 20 20 20 6

H s mt p Loss head (m/m) 0.0034 0.0187 0.0176 0.0259 0.0034

Mt p ng Total loss head (m) 1.13 0.37 0.35 0.52 0.02

Van 1 chiu Check valve Tng mt p (m) Total loss head

0.3991

1.20 3.60

-> Tn tht p lc do ma st theo chiu di ng. Cho mng li cha chy l 10% (TCVN4513-6.16) Loss head another, 10% total loss head - Mt p do ng ng : H3 = 3.95 m Loss head of pipes Tn tht p lc trn cun vi (TCVN4513-6.19) Loss head of hose reel Kp = 0.012 H s sc cn ca ng vi rng Dn50 Coefficient of hose reel Dn50 2 q= 2.5 Lu lng ct nc cha chy (l/s) p Fire fighting Water flow (l/s) -> l= 25 Chiu di ng vi rng (m) Length of Hose reel (m) H41 = 1.88 m Tn tht p lc ti u lng phun (TCVN 4513-6.18) Lose head of nozzle (TCVN 4513-6.18) -> H42 = 21.00 m -> H4 =H41+H42= 22.88 m Ct p bm : Head of water fire pump Hp1 = (H1+ H2 + H3+H4) x = 46.00 m Vi : h s an ton = 1.2

H K .q .l

d.2> Trng hp 2: cha chy t ng Case 2: Sprinkler fire fighting ng knh (mm) Diameter (mm) 150 100 Tng mt p (m) Total loss head -> Tn tht p lc do ma st theo chiu di ng. Cho mng li cha chy l 10% (TCVN4513-6.16) Loss head another, 10% total loss head - Mt p do ng ng : H3 = 19.17 (m) Loss head of pipes - Tn tht p lc ti u phun H4 = 5.00 (m) Loss head of nozzle - Ct p bm (trng hp 2): Head of water fire pump (case 2) Hp2 = (H1+ H2 + H3 + H4) x = 42.50 (m) Vi : h s an ton = 1.2 Chn bm c ct p, H = Choose Head pump, H = 5./ Tng kt thng s k thut h thng : Summary system Bm cha chy Fire pump H bm cha chy Fire fighting water pump Bm cha chy in Fire fighting electrical water pump Bm cha chy Diesel Fire fighting Diesel water pump Bm b p Jockey water pump Nc cha chy Water for fire fighting Nc tr cho cha chy Water for Fire firghting Nc cha chy Water for fire fighting 65 m Lu lng (l/pht) Flow (l/min) 1728 1728 H s mt p Loss head (m/m) 0.021240344 0.153012174 Khi lng (m, ci) Quantity (m, ea) 100 100 Mt p ng Total loss head (m) 2.12 15.30 17.43

Lu lng (m/h) Flow (m/h) 185 185 5

Ct p (m) Head (m) 65 65 70

Cng sut (kw) Power (kw) 55 3

S lng (ci) Number (set) 1 1 1

Ghi ch Note Grundfos/ Equivalent Grundfos/ Equivalent Grundfos/ Equivalent

Khi tch (m) Volume (m) 315

S lng (b) number (tank) 1

Ghi ch Note B tng Concrete

Prepare by M&E Engineer Name : Nguyn Ngc Ton Signature :

Approval by M&E Chief Name : L Vn Xun Signature :

Approval by M&E Manager Name : Trn L Quang Signature :