You are on page 1of 16

IS CODES -CIVIL(Strl.

VKMEHTA
MAIN CODES
 CODE OF PRACTICE FOR PLAIN & REINFORCE
CONCRETE IS:456-2000
 CODE OF PRACTICE FOR GENERAL
CONSTRUCTION IN STEEL IS:800-2007
 CODE OF PRACTICE FOR DESIGN LOADS
IS:875 PART 1 TO 5
 CRITERIA FOR EARTHQUAKE RESISTANT
DESIGN OF STRUCTURES :

IS:1893 (PART-1 & PART -4)


CODES FOR FOUNDATION
DESIGN
 CODE OF PRACTICE FOR DESIGN &CONSTRN.
OF PILE FOUNDATIONS IS:2911.
 CODE OF PRACTICE FOR STRUCTURAL
SAFETY OF BLDGS - SHALLOW
FOUNDATIONS IS:1904.
 CODE OF PRACTICE FOR DESIGN & CONSTN.
OF RAFT FOUNDATIONS IS:2950
 CODE OF PRACTICE FOR DESIGN & CONSTN.
OF MACHINE FOUNDATIONS IS:2974.
RCC DESIGN
 CRITERIA FOR BLAST RESISTANT DESIGN OF
STRUCTURES( FOR EXPLOSIONS ABOVE
GROUND ) IS:4991.
 EARTHQUAKE RESISTANT DESIGN &
CONSTN. OF BUILDINGS IS:4326.
 C.O.P. DUCTILE DETAILING OF R.C.
CONCRETE STRUCTURES S. T. SEISMIC
FORCES IS:13920.
 C.O.P. FOR CONCRETE STRUCTURES FOR
STORAGE OF LIQUIDS IS:3370.
 CRITERIA FOR DESIGN OF RCC CHIMNEYS
IS:4998.
STEEL STRUCTURAL DESIGN
 USE OF COLD FORMED LIGHT GAUGE STEEL
STRL. MEMBERS IN GENERAL BUILDING
CONSTRUCTION IS:801.C.O.P.
FOR USE OF STRL. STEEL IN OVERHEAD
TRANSMISSION LINE TOWERS IS:802.
 COP FOR USE OF STEEL TUBES IN GENERAL
BUILDING CONSTRUCTION IS:806.
 C.O.P. FOR USE OF METAL ARC WELDING FOR
GENERAL CONSTRUCTION IS:816.
 C.O.P. FOR DESIGN & CONSTRUCTION OF
STEEL CHIMNEY IS:6533
IS STANDARD PUBLICATIONS
CONCRETE
 SP-16 DESIGN AIDS FOR REINFORCED
CONCRETE TO IS 456-1978.
 SP-22 EXPLANATORY HANKBOOK ON
CODE FOR EARTHQUAKE.
 SP-24 EXPLANATORY HANKBOOK ON
CODE FOR PLAIN &REINFORCED
CONCRETE IS456:1978.
 SP-34 HANK BOOK ON CONCRETE
REINFORCEMENT & DETAILING.
BIS SPECIAL PUBLICATIONS
STRL STEEL
 SP6(1 TO 7)
 6.1 STRL STEEL SECTIONS.
 6.2 DESIGN OF BEAMS & GIRDERS.
 6.3 DESIGN OF COLUMNS
 6.4 DESIGN OF BOLTS.
 6.5 LIGHT GAUGED SECTION.
 6.6 PLASTIC DESIGN
 6.7 SIMPLE WELDED GIRDERS.
 SP-38 HANKBOOK OF TYPIFIED DESIGN OF ROOF
TRUSSES
 SP-40 STEEL PORTAL FRAMES
NATIONAL BUILDING CODE
OF INDIA 2005
•PROVISION OF ALL BUILDING RELATED CODES
INTERWOVEN INTO SINGLE CODE.
•FIRE & SAFETY

•BUILDING MATERIAL

•STRUCTURAL DESIGN ASPECTS

• FOUNDATION
• RCC STRUCTURE
• STEEL
•SERVICES( AIRCONDITIONING/ESCALATOR/LIFT

/PLUMBING / LANDSCAPING ETC)


ATTACHMENTS
IS 875:-DESIGN LOADS FOR BLDGS.&
STR.
(OTHER THAN SEISMIC)
 PART 1 DEAD LOADS
 PART 2 IMPOSED LOADS
 PART 3 WIND LOADS
 PART 4 SNOW LOADS
 PART 5 SPECIAL LOADS & LOAD COMBINATIONS.
 TEMPERATURE EFFECTS
 HYDROSTATIC & SOIL PRESSURE.
 STRUCTURE SAFETY DURING CONSTRCUTION
 ACCIDENTAL LOADS.
 LOAD COMBINATIONS
1893 :CRITERIA FOR EARTHQUAKE
RESISTANT DESIGN OF STRUCTURES
 PART 1(2002) fifth Revision
 GENERAL PROVISION IN BUILDINGS.
 PART 2*
 LIQUID RETAINING TANKS(GROUND & ELEVATED).
 PART 3*
 BRIDGES & RETAINING WALLS
 PART 4(2005)
 INDUSTRIAL STRUCTURE INCLUDING CHIMNEY
 PART 5* DAMS & EMBANKMENTS
* to be issued?
IS 3370:-LIQUID RETAINING
STRUCTURES

 PART 1 GENERAL
 PART 2 RCC
 PART 3 PRESTRESSED
 PART 4 DESIGN TABLES
IMPOSED LOADS AS PER EIL
DESIGN BASIS
 Process Building/Technological Structure
(Open/Enclosed type)
 Operating area - 5.0 kN/m2
 Maintenance area - 7.5 kN/m2
 Compressor House/TG house
 Operating area - 7.5 kN/m2
 Maintenance area - 7.5 kN/m2
 Substation/Control Room
 Panel floor - 10.0 kN/m2

FIGURE 1 OF IS875 PART 3

SPEED
VARIES FROM
33 TO 55M/S
SEISMIC ZONE OF INDIA
!!!!

THANK YOU!