You are on page 1of 2

ELECTROSTATIC PRECIPITATOR ENQUIRY DATA SHEET

1. Source of Gas

Boiler Flue gas

2. Type of Boiler

AFBC Boiler

3. Boiler Capacity

16 TPH, 21 Kg/Sq. cm, 350+/-10 Deg.C


21 TPH, 21 Kg/Sq. cm, 350+/-10 Deg.C

4. Type of Firing

Over bed

5. Fuel to be used

100% Rice Husk

6. % Excess Air

35% maxi., 25% min.

7. GCV of Fuel

Rice Husk 3275 Kcal/Kg

8. Fuel Analysis
Ultimate Analysis
Description
Carbon
Hydrogen
Nitrogen
Oxygen
Sulphur
Moisture
Ash

Rice Husk
36.14
3.7
0.46
29.34
0.08
8.92
21.36

9. Flue gas Analysis


Description
CO2
H2 O
N2
O2
SO2

Rice Husk 100%


13.66
10.64
70.9
4.8
0.01

10. Flue Gas Flow


Description
Gas Flow, m3/sec

16 TPH Boiler
8.75

21 TPH Boiler
11.5

11. Gas Pressure at inlet

-110 mmWC (Operating)

12. Gas Pressure for Design

+/- 400 mmWC

13. Gas Temp. at inlet

135 Deg. C

14. Dust to be handled

Rice Husk Ash

15. Type of Dust

Abrasive

16. Inlet Dust Concentration

25.64 gm/Nm3 (Max.)

17. Emission Level (Reqd.)

150 mg/Nm3

18. Location of Site

Near Sangrur (Punjab

19. Ambient Temp.

48 0C (Maxi.), 2.2 0C (Min.)

20. Relative Humidity

20 80 % (60% Average)

21. Seismic Load

Seismic Zone 4

22. Wind velocity

47 Km/hr

23. ESP Data


a. Ash hopper valley angle

600

b. Clearance below hopper

Min. 2.5 m