Cdigos de error de televisores LCD de la marca SONY

RECOPILADOS POR PROF. LUIS DAVILA 03/02/2014

Enlace a modos de servicio y mens

Service menu codes

Red led light blinks flashes, red light error code troubleshooting Chart: N of blinks 2 red flashes 3 red flashes 5 red flashes 6 red flashes 7 red flashes 8 red flashes 11 red flashes 12 red light flashes 13 red flashing 14 red flashes Faulty Section is bad power board is bad main or power board is bad lcd panel connection or internal lcd short- expensive fix is backlight error check bad main board, power board or inverter boardsunplug one by one to see if tv stays on is main board over heating is main board sp prot is trident IC, bad main board is tcon error bad T-con board or bad LCD panel is backlight balance error bad lcd panel or inverter boards (common) or balancer boards on kdl-52v4100 only is HFR error bad TCON or Bad LCD panel, in this video its bad T-con board. "how to download update"

Cdigos de error cuanda parpadea LED en TV SONY LCD N de parpadeos Seccin defectuosa 2 Fuente de poder 3 Fuente de poder o tarjeta MAIN 5 Falla de conexin con el panel LCD + T-con + Corto circuito interno en el panel LCD + Reparacin muy costosa Error de backlight. Se deben comprobar las tarjetas: Main, Inverter y Power Supply desconectando una por una para aislar la falla. Mainboard con sobrecalentamiento Mainboard sp proteccin IC Trident: mainboard daada error de T-CON o panel LCD daado Error de consumo en backlights, algunas lmparas consumen mas que otras o panel LCD daado. Puede ser dao en circuito inverter. T-CON o panel LCD

6 7 8 11 12 13 14

SONY BRAVIA - KDL-32CX525 - KDL-40CX525 - KDL-46CX525 LED BLINKING CODES DETAILS


LED BLINKING CODES & DETAILS

A loss of REG12V from the power supply triggers this protect event. This symptom is usually remedied by replacing the power supply board. If the error continues after the power supply board is replaced, suspect excessive loading which is causing the power supply to shut down. This is usually caused by a failure of the inverter circuits. Unplug the inverter and turn the TV back on. If a 6X error is displayed, the inverter (or LCD panel) must be replaced. 3 BLINKS The first thing to check when a 3X blink protection mode occurs is the physical condition of the speakers and speaker connections. The speakers should measure 8 ohms. Shorted speakers or connections can cause a 3X blink protection mode.

If the speakers and connections check okay, then the defective component is on the main board. Either an open F4200, defective DC regulator or defective audio amplifier will cause a 3X blink protection mode which would require replacing the main board. A defect on the Power Supply Board may also cause a 3X blink protection mode and shut-off. Check the AU12V level at CN6704/pin 14. If 0V is measure before shut-off the power supply board needs to be replaced. 5 BLINKS A communications error with the timing control circuits (TCON) has occurred. If the TCON is available for replacement, replace the TCON. If the TCON is not available, the LCD panel must be replaced since the TCON circuit is part of the LCD panel assembly. In rare cases a loose or defective LVDS cable could also be the cause. 6 BLINKS If the inverter circuits fail to generate high voltage or one or more of the backlight lamps fails to light, the television will shut down and display this diagnostics error. Observing for the presence of backlighting is crucial in determining which component is likely at fault. If the backlights turn on before the 6X shutdown occurs, it is safe to assume that the inverter circuits are functioning and one of the lamps failed to ignite. Replacing the LCD panel is necessary. If the backlights never turn on before the 6X shutdown, the inverter has failed. If the inverter is available for replacement, replace the inverter. If the inverter is not available, replace the LCD Panel. 7 BLINKS A digital thermometer IC located on the main board provides a temperature reading of the chassis and LCD panel. If the temperature exceeds a pre-determined point the TV will shut down. If this problem occurs immediately at turn-on, the temperature sensing IC has failed and replacing the main board is required. If this occurs after the TV has been running for a while, check for ventilation issues that could cause the TV to run hotter than normal. LED BLINK COUNTS