You are on page 1of 1

COPPER LIGHTENING CONDUCTOR 25mm DIA 2.0 MT. LONG CONNECTED BY G.I.

STRIP 25mm WIDE & 3mm THICK. VENT.

SPECIFICATIONS :
MANHOLE 800X800 3mm TH. M.S. FLAT & 80x80x4 ANGLE FRAME 25 G.I. CLASS - B PIPE RAILING
IN TWO ROWS WITH PAINTING

COPPER LIGHTENING CONDUCTOR 25 G.I. CLASS - B PIPE RAILING


IN TWO ROWS WITH PAINTING

1000 HIGH 65X65X6 ANGLE IRON POSTS @1500C/C


WITH PAINTING

70mm DIA PULLEY

WITH PAINTING

Extra Concrete 150mm Thick 300 FREE BOARD

Extra Concrete 150mm Thick


900 600 300 150

INLET PIPE

C.I. COWL WITH BEND VENT. 1000 HIGH 65X65X6 ANGLE IRON POSTS @1500C/C

VTC

LEVEL INDICATOR OF M.S. SHEET 20 GAUGE & M.S. ANGLE 35x35x5 FRAME SLOGAN & LOGO

FSL 150 DEAD STORAGE 6mm TH.X 50mm WIDE M.S. FLAT

DJ NRV DJ SV

STAINLESS STEEL WIRE 4 mm TH. COPPER FLOAT PLATE FORM BOTTOM BEAM

BYEPASS

ALUMINUM LADDER

D.I. OVER FLOW PIPE

D.I. OUTLET PIPE

BALCONY

D.I. WASH OUT

900
DRAIN

C.I. PUDDLE COLLAR

C.I. PUDDLE COLLAR

RCC COLUMN

BRACE
50x6 FLAT INLET PIPE
OVER FLOW PIPE

C.I. PUDDLE 1000mm

MS BUSH

PLATE FORM SUPPORTING BEAM

DETAIL OF CLAMP FOR FIXING PIPE

300

DETAIL OF PUDDLE FIXING

FSL 25 DIA HOLES 12 NOS

BRACE

100

650 Extra reinforcement(straight and cross bars) 10 tor - 2 Nos. on all four sides of circular hole
1000 HIGH 65X65X6 ANGLE IRON POSTS @1500C/C
WITH PAINTING

FLOAT TANK 4 MM GI SHEET

1650

BRACE

25 G.I. CLASS - B PIPE RAILING


IN TWO ROWS WITH PAINTING

AUX. FLOAT VALVE 25MM DIA.

Extra reinforcement around circular opening for ventilator in dome


LANDING PLATE FORM BEAM

FLOAT M16 BOLT INTERNAL PLATEFORM AT TOP

ELEVATION
SUPPORTING BEAM

SL W A IS T

COLUMN

INTERNAL PLATEFORM AT BOTTOM

DETAIL OF EXTRA REINFORCEMENT FOR PUDDLE COLLAR

DETAIL OF STAIR CASE

TYPICAL INFET ARRANGEMENT


10 @100c/c 3#16 BARS 6#12 BARS 3 - 8 DIST. BARS PIT BEAM 300x300 8 TIES @190c/c TIES 10 @100c/c

600

300

150

800x600

600
1500 MIN

460

890x690 825x625

150 300

GL

100

230 300

GI STRIP 25X3

3#16 BARS

1300

300 X- SECTION OF COLUMN FOR FLOAT VALVE PLATFROM (M-30)

300

GI NIPPLE 40MM
250

SALT COAL
250

12 mm MS HOOK

D.I. OVER FLOW PIPE

D.I. WASH OUT

250

D.I. OUTLET PIPE

D.I. INLET PIPE

900X900

1700

COPPER PLATE 450x450x3MM

250

COLUMN

EARTHING PIT DETAILS

1.00 mt.
FROM FALL OF BALCONY OR EDGE OF FOOTING, WHICHEVER IS MORE

PLAN OF MAN HOLE COVER

PRECAST COVER 100mm THK


STRUNG HINGES (2 NOS.) 10 @100c/c M.S. Flat 5mm

MIN. 1600

M-15 C.C. 150mm WIDE TOE WALL

150

1000

150 150 600

150

1000

150

4 - 8 DIST. BARS

3#16 BARS

PLAN OF BULK METER ROOM PLINTH LVL. SLAB


2#16 BARS

D.I. WASH OUT PIPE SIDE SLOPE - 1 IN 500 SURFACE DRAIN LEAN CONCRETE 150 THICK - M 15

150
D.I. INLET PIPE SV

G.L.

ISA 50x50x6 R.C.C. DOME

150 300 800


CHAMBER

BEAM 300x300 10 @100c/c

300
BEAM 300x300

COMPACTED SOIL

DUCK FOOT BEND

DUCK FOOT BEND

450 100 450

600x600 G.L.
CHAMBER 1000 1200 1800

SECTION OF MAN HOLE COVER

300 300
3#16 BARS

8 @150c/c

VALVE CHAMBER 1000x1000

3#16 BARS

SECTIONAL ELEVATION
150

8 MESH @ 150C/C BOTHWAY & ON BOTH FACES


150

SECTION OF BULK METER ROOM BEAM 300x300 M-20


100

PLAN OF CHAMBER (M-20)

100 TH. ( M-15 P.C.C. )

SECTION FOR FLOAT VALVE PLATFROM (M-30)

SECTION OF CHAMBER (M-20)

SV

12 MM dia bolt

Extra Conc. 150mm Thick Around Puddle

ARRANGEMENT OF R.C.C. LADDER BETWEEN BALCONY AND STAIR

TO

INLET PIPE

OUTLET PIPE WASH OUT PIPE

PIPING ARRANGEMENT PLAN

600

INLET PIPE

800
OVER FLOW PIPE INTERNAL PLATEFORM AT BOTTOM

WASH OUT

OUTLET PIPE PIPE

INTERNAL PLAN FOR PLATFORM

C.I. COWL 3 MM

150 150 300 150 300

S.S. MOSQUITO PROOF JALI

50 WIDE 3 TH. MS PLATE WELDED TO PIPE

OVER FLOW PIPE

TYPICAL SECTION TYPICAL SECTION THROUGH OVERFLOW PIPE THROUGH WASHOUT PIPE

TYPICAL SECTION THROUGH INLET PIPE

TYPICAL SECTION THROUGH OUTLET PIPE

TYPICAL DETAIL OF CLAMP FOR FIXING PIPE (PLAN)

OUTLET PIPE

RAILING

D.I. INLET PIPE

INLET PIPE

R.C.C. LADDER

SV

M.S. LADDER WITH CAGE 50x50x6 ANGLE IRON & 25mm M.S. BARS @ 300c/c

PUDDLE COLLARS PUDDLE COLLARS SHALL BE USED FOR CONNECTING THE INLET, OUTLET, OVERFLOW & WASHOUT PIPES TO THE RESERVOIR. ALL PUDDLES SHALL BE FIXED AT RIGHT ANGLE TO THE RCC WALL DURING CASTING OF WALL. ALL PUDDLE COLLARS SHALL BE OF C.I. THE MINIMUM LENGTH SHALL BE AT LEAST 100 MM MORE THAN THE TOTAL FINISHED THICKNESS OF THE WALLS AND SIZE OF THE PUDDLE COLLARS SHALL BE EQUAL TO THE SIZE OF THE RESPECTIVE PIPE. FLOAT VALVE SYSTEM THE FLOAT VALVE SYSTEM SHALL BE INSTALLED AT THE END OF INLET PIPE IN EACH OHSR. THE FLOAT VALVES FOR OHSR SHALL COMPRISES OF TWO FLOAT VALVES I.E. MAIN FLOAT VALVES AND THE AUXILIARY FLOAT VALVE. THE DIFFERENT MATERIALS OF CONSTRUCTION FOR THE COMPONENTS & OTHER DETAILS SHALL BE AS PER TENDER DOCUMENT. LADDER M.S. LADDER 450 MM WIDE, MADE UP OF 50MM X 50MM X 6MM M.S. ANGLE IRON AND 25MM M.S. BARS WELDED AT 300MM C/C SHALL BE PROVIDED OUTSIDE FROM THE BALCONY TO TOP DOME IN OHSR. MS CAGE SHALL ALSO BE PROVIDED ON THIS LADDER. SIMILARLY MS LADDER/RCC STAIRCASE SHALL BE PROVIDED AT SR FOR ACCESS TO THE TOP DOME. M.S. LADDER WITH ALL ITS COMPONENTS SHOULD BE SUITABLY PAINTED AS PER APPROVAL OF EIC. THE LADDERS IN ALL TYPE OF RESERVOIRS (I.E. CWR & OHSR) FROM TOP DOME ROOF TO INSIDE PLATFORM AND FROM PLATFORM TO BOTTOM DOME IN THE CONTAINER SHALL BE AS PER TENDER SPECIFICATIONS. RAILING HAND RAILING SHALL BE PROVIDED ALONG THE STAIRS OF OHSR AND ON THE TOP DOME OF OHSR. HAND RAILING AROUND THE PLATFORMS, BALCONY, STAIRS AND LANDINGS SHALL BE CONSISTING OF 25 MM DIAMETER MEDIUM B CLASS GI PIPES IN TWO ROWS (ONE AT THE TOP AND OTHER AT MIDDLE LEVEL) AND 1000MM HIGH VERTICAL POST 65X65X6 MM ANGLE IRON @> 1500MM CENTRE TO CENTRE PROPERLY EMBEDDED IN THE CONCRETE(AT LEAST TWO VERTICAL ANGLES ARE TO BE PROVIDED WHEREVER DISTANCE IS LESS) WITH ALL ACCESSORIES LIKE ELBOWS, TEES ETC. INCLUDING WELDING, THREADING AND EMBEDDING IN CEMENT CONCRETE FLOOR. RAILING SHALL BE PROTECTED AGAINST CORROSION AFTER WELDING. THE PIPE SHALL PASS THROUGH HOLE IN THE VERTICAL ANGLE. WATER LEVEL INDICATOR WATER LEVEL INDICATOR SHALL BE CONSISTING OF AN APPROVED FLOAT AND AN IRON COUNTER WEIGHT CONNECTED TO A FLEXIBLE STAINLESS STEEL WIRE 4MM THICK PASSING OVER PULLEY 70MM DIAMETER. THE PULLEYS SHALL BE PROPERLY FIXED WITH STRUCTURE AND SHOULD HAVE A GUIDE SO THAT THE WIRE DOES NOT SLIP FROM THE PULLEY. THE SCALE SHALL BE CALIBRATED IN CENTIMETERS AND SHOULD CONSIST OF M.S. SHEET 20 GAUGE FIXED OVER WOODEN PLANK WITH AN M.S. ANGLE IRON FRAME OF 35MM X 35MM X 5MM AND PAINTED WITH WHITE ENAMEL BASE, LETTERS IN BLACK AND RED. THE SCALE SHALL BE LOCATED AND FIXED WITH RCC VERTICAL WALL OF OHSR. VENTILATOR VENTILATORS SHALL BE PROVIDED FOR ALL RESERVOIRS. THE SIZE OF VENTILATOR SHALL BE APPROVED BY EIC IN CONSIDERATION TO THE TANK SIZE AND SHALL BE OF CI COWL AND A BEND OF 300 MM HIGH WITH MOSQUITO PROOF JALI OF STAINLESS STEEL SHALL BE FIXED AT THE OPENING. IT SHALL BE WELL PAINTED AND PROPERLY FIXED IN CONCRETE. THICKNESS IN CASE OF MS SHALL BE NOT LESS THAN 3 MM. FOR SMALLER RESERVOIRS CI VENT PIPES OF DIA AS PER APPROVAL OF EIC SHALL BE PROVIDED. LIGHTENING ARRESTER LIGHTNING ARRESTER SHALL BE OF COPPER BAR OF 25MM DIA AND 2M LONG TO BE PROVIDED AT THE TOP OF OHSR. THIS IS TO BE CONNECTED BY A GI STRIP 25 MM WIDE & 3MM THICK. THIS CONDUCTOR STRIP SHALL BE CONNECTED TO A 450 MM X 450MM X 3MM THICK COPPER PLATE TO BE EMBEDDED BELOW THE AVERAGE GROUND LEVEL BY DIGGING A PIT. THE EARTHING SYSTEM SHALL COMPLY WITH INDIAN ELECTRICITY RULES AND SHALL CONFIRM TO IS 3043. THE PIT SHALL BE REFILLED BY ALTERNATE LAYERS OF SALT AND COKE AND BALANCE SHALL BE FILLED WITH LOOSE SOIL. THE 40 MM DIA GI WATERING PIPE SHALL BE PROVIDED IN THE PIT. CARE SHALL BE TAKEN THAT EARTH PIT DOES NOT SINK. PLINTH PROTECTION PLINTH PROTECTION WORKS FOR OHSR IS TO BE PROVIDED ALL AROUND EACH RESERVOIR IN A 1 M CIRCULAR STRIP. IT SHALL CONSIST OF LAYING LEAN CONCRETE 150 MM THICK IN M10, OVER COMPACTED SOIL. ALONG THIS PLINTH PROTECTION PROVISION OF TOE WALL OF M15 GRADE CEMENT CONCRETE 150 MM WIDE OVER THE BASE OF LEAN CONCRETE OF M10 SHALL BE PROVIDED. SIDE SLOPE OF PLINTH PROTECTION SHALL BE 1 IN 50 OUTWARD & PERIPHERAL SLOPE SHOULD BE 1 IN 500. PLINTH PROTECTION WORKS TO BE CONSTRUCTED BELOW THE OH SERVICE RESERVOIR, SHALL BE EXTENDED UP TO 1M FROM FALL OF BALCONY OR EDGE OF RAFT SLAB, WHICHEVER IS MORE.. SLOGAN AND LOGO THE CONTRACTOR SHALL PAINT ON THE VERTICAL WALL OF THE TANK PORTION BY USING 3 COATS OF PLASTIC EMULSION PAINT OF SHADE AS APPROVED BY ENGINEER IN CHARGE TO FORM A BASE FOR WRITING THE SLOGAN. THE SIZE & SHADE FOR PAINTING THE SLOGAN WILL BE APPROVED AND DIRECTED BY ENGINEER IN CHARGE. THE LOGO SHOULD INDICATE THE NAME OF THE PROJECT, NAME OF THE VILLAGE AND THE CAPACITY OF THE RESERVOIR. THE SLOGAN SHALL BE AS DIRECTED BY THE ENGINEER-IN-CHARGE. PIPE CLAMP AT LEAST TWO CLAMP ON ONE STAGING SHALL BE PROVIDED OF 6MM THICK 50MM WIDE MS FLAT FIXED ON PIPE & COLUMN. MAN HOLE COVER SQUARE MANHOLE COVER 800X800 MM SHALL BE PROVIDED. THE COVER SHALL BE MADE OF 5 MM THICK MS FLAT. THE FRAME SHALL BE MADE OF MS ANGLE 50*50*6. THE COVER SHALL BE CONNECTED TO THIS FRAME BY USING TWO NOS. STRUNG HINGES. LOCKING ARRANGEMENT SHALL BE PROVIDED.

DJ

FM

OUTLET PIPE

GENERAL ARRANGEMENT OF R.C.C. RESERVOIRS


DETAIL OF VENTILATOR
EXECUTIVE ENGINEER PHED, PROJECT DIVSION GULABPURA

M/S PRATIBHA INDUSTRIES LIMITED BANERA HURDA PROJECT BHILWARA.

You might also like