You are on page 1of 1

C

1. DO NOT SCALE FROM DRAWNGS. USE WRTTEN DMENSONS ONLY.


2. BULDER TO CHECK & VERFY ALL DMENSONS & LEVELS PROR TO
COMMENCEMENT OF WORK.
3. T S THE OWNERS RESPONSBLTY TO ENSURE THAT THE ENGNEER
HAS NVESTGATED SUBSOL CONDTONS & DESGNED ALL
STRUCTURAL ELEMENTS TO SUT.
4. THE DESGN & DETALS CONTANED ON THS DRAWNG S SUPPLED N
CONFDENCE & S NOT TO BE USED FOR ANY OTHER PURPOSE,
EXCEPT THATAUTHORSED BY DEANGELS TAYLORAND ASSOCATES
Drawing No.
WD02
Amend't
E
No. of sheets
Job No.
10099
Drawn:
B.T
ScaIe:
As shown @A1
Project:
Dwg Name:
Address:
Nominated Architect:
CAD File: Z:\2010\10099.Liverpool Council.Rose St\3.Design\3.3 WD\10099.WD.(D).Rose St.Liv Council.pln
I: 1 2 01 1011 f: 1 2 821 2213 w: www.cI c.neI .cu
8 8 L c I h u r : I : I r e e I | i v e r p c c | n : w 2 1 7 0 c u : I r c | i c
pc Lcx 8 | i ver pcc| Lc n: w 1871 e: ccmi n@ cI c.neI .cu
Issue Amendment
P1
Drwn Date Chk'd
07.06.2011 AB BA PRELMNARY SSUE
CIient: Project North:
LIVERPOOL
CITY
COUNCIL
STEPHEN TAYLOR.....................................................................................
NSWArchitects Registration Board No. 7414 2 of 13
or ch| t ect ur e | nt er | or des| gn ur bon des | gn
COPYRGHT 2010 - DE ANGELS TAYLOR + ASSOCATES PTY LTD
ROSE STREET DEPOT - FITOUT CONTRACT
ROSE STREET LIVERPOOL NSW 2170
OVERALL SITE PLAN
14.02.12
Date:
P2 30.06.2011 AB BA PRELMNARY SSUE
A 11.08.2011 AB BA CONSTRUCTON SSUE
C 14.02.12 BT ST SSUED FOR TENDER
D 24.02.12 BT ST SSUED FOR TENDER
E 27.02.12 BT ST AMENDED FOR TENDER
d e o n g e I | s t o y I o r + o s s o c | o t e s
| | 0 K | t 0 J | 0
J | k L 1 1 0 0
w w w . d |a |b e fo re y o u d |g . com . au
EXSTNG TREES TO REMAN. REFER ALSO TO
LANDSCAPE DRAWNG.
SWP
58.03
EXSTNG LEVEL. REFER ALSO TO SURVEY.
STORMWATER PT. REFER ALSO TO DRANAGE
DRAWNG.
TEL
EXSTNG TELSTRA PT. REFER ALSO TO SURVEY.
EXTENT OF EXSTNG BULDNGS ON STE TO REMAN
EXTENT OF ALTERATONS + ADDTONS TO EXSTNG
BULDNG
LEGEND - SITE
EXTENT OF STE BOUNDARY
EXTENT OF PROPOSED ADDTONAL NEWSTE
WORKS
20.16
20.77
20.93
20.94
21.51
20.34
20.28
20.24
20.64
20.28
19.85
19.69
19.28
19.01
18.96
19.02
19.12
20.09
20.26
20.50
20.24
20.53
20.46
20.38
20.13 20.01
20.83
19.81
19.67
20.68
20.84
20.92
20.73
20.64
20.75
20.82
20.62
20.91
20.72
20.41
20.40
20.28
19.71
19.67
19.57
19.56 19.55 19.69
19.79
19.81
19.92
19.46
19.21
19.40
19.57
19.47
19.71
19.70
19.93
19.82
19.66
19.42
19.59
19.51
19.30 19.31
19.75
19.37
19.54
19.49
19.60
19.32
19.81
19.87
20.07
19.96
19.85
20.23
19.88
19.98
19.98
20.12
20.05
20.04
19.95 19.96
20.07
20.12
19.73
20.03
19.86
19.94
19.83
19.89
19.82
19.95
19.90
20.14
20.26
19.93
19.75
19.66
19.85
19.82
19.72
19.92
19.90
19.82
19.93
19.82
22.65
18.99
19.31
19.31
19.41
19.21
19.10
19.15
19.24
19.20
19.09
19.03
24.16
18.96
19.30
19.58
19.73
19.58
19.28
19.17
19.31
19.41
19.30
20.09
19.09
19.24
19.64
19.60
19.49
20.27
20.30
20.41
20.71
20.80
20.60
20.39
20.32
20.31
20.71
20.62
20.18
21.30
21.16
21.18
20.63
20.17
20.83
20.75
18.82
19.15
19.33
19.10
19.09
19.00
19.27
19.38
19.29
19.21
19.48
20.06
20.30
20.03
19.99
19.78
19.65
19.66
19.27
19.25
19.35
19.49
23.13
19.71
19.82
20.00
19.60
19.52
19.45
19.53
19.33
19.69
19.50
19.60
20.38
19.17
18.91
19.91
20.10
20.33
19.99
20.15
20.32
20.34
20.36 20.33
20.46
21.68
21.38
21.80
20.88
22.01
22.12
20.04 20.27
20.15
19.77
19.83
22.18 22.06
20.13
20.63
20.09
20.40
20.69
20.73
20.83
20.85
19.63
19.65
20.54
20.39
20.36
20.55
20.34
20.40
20.53
20.66
20.55
19.52
19.18
19.17
19.16
19.17
19.36
19.37
19.13
19.23
19.32
19.37
19.63
22.58
19.81
CHAN WRE FENCE
C
H
A
N
W
R
E
F
E
N
C
E
KERB AND GUTTER
KERB AND GUTTER
KERB AND GUTTER
KERB AND GUTTER
KERB AND GUTTER KERB AND GUTTER
KERB AND GUTTER
EXSTNG
MECHANCAL
WORKSHOP
O
F
F
C
E
L
U
N
C
H
R
O
O
M
E
X
S
T
N
G
B
U
L
D
N
G
E
X
S
T
N
G
B
U
L
D
N
G
ROSE STREET
C
H
A
N
W
R
E
F
E
N
C
E
C
H
A
N
W
R
E
F
E
N
C
E
CHAN WRE FENCE COLARBOND FENCE
C
H
A
N
W
R
E
F
E
N
C
E
SMH
SMH
SMH
S
M
H
O
F
F
C
E
STN 9002(GN)
S
T
N
9
0
0
3
(G
N
)
S
T
N
9
0
0
6
(G
N
)
K
E
R
B
A
N
D
G
U
T
T
E
R
ELP/PP
EXSTNG MECHANCAL WORKSHOP
STAFF
TRANNG
CENTRE
E
X
S
T
N
G
O
F
F
C
E
1
DP216740
NO.74
2
DP216740
NO.72
1
DP216740
NO.70
2
DP1060576
NO.66
1
D
P
1
0
6
0
5
7
6
P
E
A
R
C
E
S
T
R
E
E
T
17
DP216740
3
DP 82270
2
DP 82270
1
DP 249314
12 13
12
NO.
OFFCE
16
DP216740
NO.21
18
DP216740
NO.24
DP216740
15
DP216740
T
E
L
S
T
R
A
C
O
M
P
O
U
N
D
W
E
A
T
H
E
R
C
O
N
T
R
O
L
S
T
A
T
O
N
S
T
N
9
0
0
8
(R
/F
)
CONC SLAB
CONC SLAB
CONC SLAB
C
O
N
C
S
L
A
B
C
O
N
C
S
L
A
B
BTUMEN AREA
BTUMEN AREA
BTUMEN AREA
BTUMEN AREA
BTUMEN AREA
GRAVEL AREA
ELEVATED STORE
AND LOADNG DOCK
WESTED PT
S
T
O
R
A
G
E
POATABLE OFFCE
SWP
SWP
SWP
SWP
SWP SWP
SWP
SWP
SWP
SWP
SWP
SWP
SWP
SWP
SWP
SWP
SWP
SWP
1
8
0
0

R
C
P
1
8
0
0

R
C
P
1
5
0
0

R
C
P
1
5
0
0

R
C
P
375 RCP
CONCRETE BAY
SWP
SERVCE
PT
GRAVEL AREA
ELP
STN 9001(GN)
ENTRY
P
A
T
H
PORTABLE
OFFCE
BTUMEN AREA
CONC AREA
PP
P
O
R
T
A
B
L
E
O
F
F
C
E
C
O
N
C
CONC D'WAY
C
O
N
C
D
' W
A
Y
T
E
L
T
E
L
TEL T
E
L
TEL TEL TEL
TEL
WM
TEL
TEL
ELP/PP
ELP/PP
PP
H
H
PP PP
SWP
C
O
N
T
A
N
E
R
S
C
O
N
T
A
N
E
R
CONTANER
CONTANER
CONTANERS
CONTANER
STN 9025
SSM 57082
PP
ELP/PP
ELP/PP
3
6
D
P
9
7
8
8
8
4
N
O
. 9
7
1
N
O
.9
5
4
DP216740
NO.68
3
NO.66
N
O
T
R
U
C
K
S
B
E
Y
O
N
D
T
H
S
P
O
N
T
S
G
N
L
V
E
R
P
O
O
L
S
.E
.S
P
U
B
L
C
R
E
S
E
R
V
E
375
RCP
1
8
0
0

R
C
P
1
8
0
0

R
C
P
3
7
5

R
C
P
3
0
0

R
C
P
3
7
5

R
C
P
3
7
5

R
C
P
375 RCP
375 RCP
375 RCP
TEL
C
O
N
T
A
N
E
R
S
225 RCP
SWP
T
E
L
W
M
DP215640
NO.64
R
E
S
D
E
N
T
A
L
A
R
E
A
P
A
C
U
L
L
O
P
A
R
K
2 0. 0
0
20 . 0 0
2
0
.
0
0
21.00
20.74
19.62
19.40
19.26
19.54
E
X
S
T
N
G
B
U
L
D
N
G
E
X
S
T
N
G
B
U
L
D
N
G
E
X
S
T
N
G
B
U
L
D
N
G
ROSE STREET
20.28
2 , 0 0 0
EXSTNG
ADMNSTRATON
PROPOSED NEW FTOUT
WORKS
COUTYARD
ESSENTIAL EMERGENCY SERVICES
H

E/L
EXTG
- HYDRANTS
- FRE EXTNGUSHERS
- FRE HOSE REELS
- EMERGENCY LGHTNGS
- LLUMNATED EXT LGHTNGS
- ALL PORTABLE FRE EXTNGUSHERS & FRE BLANKETS TO
COMPLY WTH RELEVANT AUST. STANDARDS.
- EMERGENCY AND EXT LGHTNGS TO BE STANLITE OR
APPROVED EQUAL AND SHALL COMPLY WTH ASNZS 2293.1
- REFER ALSO TO FRE SERVCES CONSULTANTS
DOCUMENTATON.
- ALL NEW WORKS TO COMPLY WTH AS1428 & PART D3 OF BCA,
ACCESS FOR PEOPLE WTH DSABLTES.
- TACTLE NDCATORS TO COMPLY WTH RELEVANT AUST.
STANDARDS.
GENERAL NOTES:
VERFY ON STE ALL SURVEY NFORMATON NCLUDNG ALL EXSTNG
SERVCES & LEVELS PROR TO CONSTRUCTON.
DEMOLSH EXTG STRUCTURES & CLEAR ALL VEGETATONAS REQURED
AND/OR AS SHOWN ON DRAWNGS, READY FOR NEWWORKS. DSPOSE OF
DEMOLSHED BULDNG MATERALSAND ASBESTOS MATERAL
ENCOUNTERED DURNG DEMOLTON, EXCEPT THOSE TEMS SPECFCALLY
DENTFED FOR REUSE.
TERMNATE, CAP OFF OR DVERT OF ALL EXSTNG SERVCES WHERE SO
REQURE AND/OR AS NECESSARY TO CARRY OUT NEW WORKS. PERFORM
ALL WORKS N BEST TRADESMAN-LKE MANNER AND TO THE SATSFACTON
OF RELEVANTAUTHORTES.
REFER TO STRUCTURAL ENG'S DOCUMENTS FOR DETALS OF CONC.
SLABS, STEPS, FOOTNGS NCLUDNG SZES OF STRUCTURAL MEMBERS.
ALL TMBER FRAMNG SZES SHALL COMPLYWTH THE TMBER FRAMNG
CODE.
COMPLYWTH LANDSCAPNG REQUREMENTS AS REQURED BY THE
COUNCL CONDTONS AND/OR AS DETALED BY LANDSCAPE ARCHTECT .
REFER TO HYDRAULC ENG'S DETALS FOR LOCATONAND LEVELS OF ALL
STORM WATERPTS. UNO. CONNECT ALL DOWNPPES NTO NEAREST
EXSTNG STORM WATERSYSTEM AS REQURED AND/OR TO HYD. ENG'S
DETALS. UNO. PROVDE FALL N GROUND FNSHES TO ENSURE ALL
STORM WATER FALLS AWAYFROM BULDNG. LAY PAVNGWTH
SUFFCENT FALL TO PT TOAVOD PONDNG.
REFER TO HYDRAULC ENG'S DETALS FOR DETALS OF SEWER
CONNECTON . COMPLY WTH RELEVANTAUTHORTES REQUREMENTS.
SUPPLY & NSTALLALL ELECTRCAL SERVCES NCLUDNG BUT NOT
LMTED TO, POWER, EXT SGNS, EMERGENCY LFTNG & TELEPHONE
SUPPLY TO RELEVANT AUST STANDARDS & AUTHORTES REQUREMENTS.
SUPPLY & NSTALLALL MECHANCAL VENTLATON NCLUDNG BUT NOT
LMTED TO, MECHANCAL EXHAUST FANS & DUCTS, AR CONDTONNG
UNTS & DUCTS TO RELEVANTAUST STANDARDS & AUTHORTES
REQUREMENTS.
REMOVE ALL REDUNDANT VEHCLE CROSSNGS & REPLACED WTH KERB &
GUTTER TO COUNCL'S REQUREMENTS. MAKE GOOD TO SURROUNDS
WHERE DSTURBED BY NEW WORKS TO COUNCL ENGNEER'S
SPECFCATON.
PROVDE PHYSCAL TERMTE TREATMENT N ACCORDANCE WTH AS 3660.1
WC WTH NWARD SWNGNG DOORS CLOSER THAN 1200mm TO THE PAN
SHALL BE FTTED WTH LFT OFF HNGES AS REQURED BY BCA.
UNO. PROVDE 50mm SET DOWN N FLOOR SLAB TOALL WET AREAS. LAY
PAVNGWTH SUFFCENT FALL TO FLOOR WASTE TOAVOD PONDNG.
MAKE GOOD TOALL SURFACES, DAMAGED / EFFECTED DURNG NEW
WORKS
AT COMPLETON CLEAN UP THE STE PROR TO HAND OVER. MAKE GOOD
TO SURROUNDS WHERE DSTURBED DURNG NEWWORKS.
1
OVERALL SITE PLAN
1:500
GENERAL WALL NOTES
PLASTERBOARD CONTRACTOR TOALLOW FOR ALL NOGGNG TO
CATER FOR HANDLES, HARDWARE FTTNGS.
PROVDE FC LNNG ON FURRNG CHANNELS TO SOLD MASONRY
WALLS FOR PLUMBNG BEHND SANTARYFTTNGS
USE MN. 92mm STUD FOR PLASTERBOARD WALLS, F A URNAL OR 2
OR MORE VANTY BASNS ARE TO BE FXED AGANST THAT WALL
PROVDE ALUMNUM SKRTNGS TOALL WALLS EXCEPT WHERE
SKRTNG DUCT, CERAMC TLE OR VNYL SPECFED
REPLACE EXISTING ROOF SHEETING
TO MECHANICAL WORKSHOP
WITH SELECTED COLORBOND METAL
ROOF SHEETING

You might also like