To calculate Critical heat flux: 1)1St heat flux

2) second heat flux by following formula

C6)Sat vapor enthalpy-sat.liq enthalpy=latent heat C7)ENTHALPY=Sat.liq enthalpy+(x*latent heat) C26)Total heat duty=mf*enthalpy C27)Sensible heat load=mf*((Cp of water @ 40+Cp of water @ 120)/2)*(water temp at 40-feed water temp@ 30) Total heat duty=sensible heat load +latent heat load C28)Latent heat load=total heat duty-sensible heat load C31)Ideal fuel requirement=total heat duty/Cv C33)Actual air req=Ideal fuel req*air req @ 25% excess E27) total heat duty in sec=total heat duty in hr/3600 C34)Blower flow rate=actual air req*1.2 C39)Flue gas flow rate=ideal fuel req+actual air req C41)Reynold no=(density*flue gas velocity*dia)/(density*kinematic viscosity) C43)Nu=0.023*(Re)0.8*(Pr)0.33 C55)heat load=mf*enthalpy C56) time=(heat load/((40/0.6)*Cv))*60 M46)dia of shell=1.44*(no.of tube*((OD*1.25)/1000)2)

M40)flue gas flow rate=blower flow rate/(Cp*(flue gas inlet temp-(flue gas inlet temp-150)))*36000 M29)hi=(Nu*k)/((OD-2*t)/1000) M32)Overall htc=(1/ITC)+(1/OTC) O37)HTA=(total heat duty/3600)/(overall HTC*LMTD)*1000/4