You are on page 1of 18

:

Step7 AS-I

AS-Interface
DP/AS-Interface Link Step7 .



.


.
.
PLC
HMI SCADA .


1980 Honeywell
4 20 .
.
. .
. Field device
. Fieldbus
Transducer ,Sensor,Transmitter -

.

. .

AS-I,Profibus,CAN,Modbus,Hart,DeviceNet,EIB,Instabus,BitBus

AS-I
AS-I Actuator Sensor Interface
Open
Fieldbus IEC62026 EN50295
. 1991

AS-International 1996 As-i ATO Trade
Organization .

. AS-I
Gateway .
Profibus,CAN,Modbus,DeviceNet,InterBus...

AS-I
.1
AS-I
.
.
AS-I terminators GSD) . (

.2
AS-I
.

.3

.
LED
. AS-I )( star, bus, tree, ring
100 ) (Repeater
300 . AS-I Terminators
.

.4
AS-I 50
.
.

.


Actuator Sensor Interface
.
:

.1:

.2 :
.3 :
.4:
.5:

single-master

Slave Master

) linear, ring, star (tree

) (2x 1.5 mm

) 24 (DC 200 Slave 8


.BUS

.6 :
.7 :
.8:

100 300 )(repeater

8 .

.9
.10:

)(piercing

:Slave 62 Slave )(version 2.1

4 4 Slave Slave 31 3 )

248 / (.

.11

:Cycle time 5 10 v2.0 v2.1

.12 :

:Master Slave Slave ) PLC .(PC

Slave .Slave
Slave.

PLC

:
:
:

AS-I

Stop


AS-I.
AS-I Master/Slave .
Master PLC AS-I
Slave . Slave
. Slave
1 31
2
Master 2-
. Slave
20 Slave
.
Master 167kbps 1 5
31 . Master
Slave .

Slave :
.1 :
Chip AS-I
Smart Slave
Node
.

.2 : AS-I
ASI Module



Node .

Slave
As_I Addressing Unit PLC
. .
.
4 4
31 124 124 .
v2.1 2
.

As-I Flat
1.5 .
180 75
.
copolymer
.
AS-I
!
.
.

Master
Slave .

ASI (Frequency Shift Keying) FSK


.

Master Slave
100
. Repeater,Tuner Terminator
1000 .
: Terminator.1

. 100 1
. Terminator
2 .
:Repeater.2 Node

. AS-I 2
4 .

: Tuner.3 Tuner 300 .

Star,Line,Tree,Branch Line Slave


Master .

DP/AS-Interface Link
DP/AS-Interface Link
AS-I Profibus.
.

11

AS-Interface
9 Profibus RJ-45 Ethernet
.

EEprom
.
Optional C-PLUG
Backup .
.

C-PLUG . -
:

LED :DP/AS-Interface Link


LED
:
) :SF (System Fault LED
DP Master DP/AS-Interface
EEPROM .
) :BF (BUS Fault LED
profibus-DP
GSD .
:ON LED .

LED :AS-Interface
) :APF (AS-I Power Fail LED AS-I
.
) :CER (Configuration Error LED :
Slave AS-I .

13

DP/AS-Interface Link Offline .


Slave DP/AS-Interface .
Slave AS-I .
) :AUP (Autopray Available LED
.
) :CM (Configuration Mode LED
Protected Configuration .
:ON LED AS-I .
DP/AS-Interface Link Advanced STEP7
Simatic manager HW Config
Profibus-DP DP/AS-i DP/AS-Interface Link Advanced
Master .

Slave AS-I .
AS_I Line
Properties Digital Address
Slave AS-I .

AS-I Slave. Slave


. Slave
.

15

Slave . SIEMENS

.
Slave


Step7 GSD
.
HW Config Option Install GSD File
Install .
Profibus-DP .

17

SIMATIC NET-DP/ASINTERFACE LINK Advanced (Manual)


www.smar.com
www.hms.se
www.fieldbus.org
www.as-interface.net
www.automation.siemens.com

You might also like