You are on page 1of 2

9500 MPR Quick Start Guide MPT-HC Overview and ODU-to-IDU

Connections
C
o
n
f
i
g
u
r
a
t
i
o
n

[
1
+
0
]
RPS module
XPIC-RPS module
[1+1] MPT-HC with RPS module
[1+1] MPT to MSS
Electrical (<100 m)
C
o
n
f
i
g
u
r
a
t
i
o
n

[
1
+
1
]
C
o
n
f
i
g
u
r
a
t
i
o
n

X
P
I
C

[
2
+
0
][2+0] MPT-HC with XPIC-RPS
module
MPT through power injector
plug-in Electrical (<100 m)
[2+0] XPIC MPT to MSS
Electrical (<100 m)
MSS-4/8
Coupler [1+1]
MPT to Ethernet device
Electrical (<100 m)
RPS LC-LC optical jumper
MPT-HC
Four captive screws open the removable cover
(no tool is required)
Optical user port
Power feed over Ethernet port
MPT to MSS
Electrical (< 100 m)
CAT5e cable
data and DC
1AC015760006
MSS-1c
MPT

access

board
CAT5e cable
data and DC
1AC015760006
Power injector plug-in
3CC50120AAXX
RJ45 cable data
Core board
RJ45 to any
switch or router
Power injector box
3CC50129AAXX
or
Power injector
plug-in
3CC50128AAXX


48 V dc
CAT5e cable
data and DC
1AC015760006
Coaxial cable
Jumper
RJ45/N
Fiber
MSS-4/8 or MSS-1c + pigtail
MPT to MSS
Optical ( >100 m)
MPT to core board or Ethernet
device Optical (>100 m)
Fiber
MSS-4/8 or any Ethernet devices
Coaxial cable to station
battery with low-pass
filter, pigtail, lightning
arrestor
Jumper
RJ45/N
To any

switch
or router
Option 2
Option 1
Maintenance port
Optical user port
Power feed over Ethernet port
Optical RPS port
Interconnection
connector
Optical port
dedicated to RPS
RPS LC-LC optical jumper 3CC52169XXXX
Note: In 1+1 configurations, you must inter-connect
the two MPT-HCs using a preassembled RPS
optical jumper and two optical SFP modules
(different lengths are available).
CAT5e cable
data and DC

1AC015760006
MSS-4/8
RPS cable
Fiber
MSS-4/8
Jumper
RJ45/N
Coaxial
cable
RPS
cable
Coupler 6, 7, and 8 GHz
Coupler 11 to 38 GHz
Note: See the applicable MPR user manual
for other supported configurations.
Optical RPS port
Maintenance port
Optical user port
Power feed over Ethernet port
XPIC port
XPIC connector dedicated to Rx signal exchange
between MPT pol H and MPT pol V
interconnection connector
MSS-4/8
c
a
t
7
e
X
P
I
C
MPT pol H
MPT pol V
MSS-4/8
Note: See the applicable MPR user manual for
other supported configurations.
Note: See the applicable MPR user manual for
other supported configurations.
XPIC

cable
OrthoMode Transducer OMT
6, 7, and 8 GHz
MPT pol V
Jumper
RJ45/N
Coaxial
cable
MPT pol H
Fiber
XPIC

cable
[2+0] XPIC MPT to MSS
Optical (>100 m)
[1+1] MPT to MSS
Optical (>100 m)
MSS-4/8
Note: See the applicable MPR user manual
for other supported configurations.
OrthoMode Transducer OMT
11 to 38 GHz
Maintenance port
Note: In 2+0 configurations, you must inter-connect
the two MPT-HCs using a preassembled RPS
optical jumper and two optical SFP modules
(different lengths are available).
CAT5e cable
data and DC

1AC015760006
2 Install outdoor unit
3 Install MPT [1+0] 4 Set MPT polarization 5
Install MPT [2+0] with OMT
9500 MPR Quick Start Guide MPT-HC Installation Steps
RJ45

connector
1AB074610027
Cat5e cable

1AB150990002
3.1 Put silicone grease on the O-ring (mandatory)
before inserting the MPT; see the following figure.
1.1
2.2
2.1
Note: MPT toolbox is mandatory
3CC50098AAXX.
1.1 Install the MSS indoor unit in one of three
supported configurations (see the applicable user
manual):


ETSI

rack (21 in.)


standard rack (19 in.)


wall mount
1.2 Ground the MSS

using the ground screw on

the front panel of the bracket on the right side of
the MSS; use grounding kit 3CC13423AAXX.
1.3 Connect the power supply cable between the
MSS and breakers or power panel:


MSS1-c and power injector box: 2x1 mm
1AC007800068


MSS4/8: 2x4 mm 3DB18271AAXX


MSS8 (full configuration): 2x6 mm
3CC52190AAXX
1.4 Install the integrated DDF; see the applicable
manual (75 , 120 , RJ45).
1.3
1.2
Note: Two pole mounting installation kits are
available: integrated antenna and non-Integrated
antenna. This procedure describes the antenna
mount only.
2.1 Install the integrated antenna mounting kit.
2.2 Verify the polarization on the antenna nose and
change it if required.
4.1 Factory delivery is in V polarization.
To change the polarization, loosen the two
screws and line up the H or V polarization with
the polarization references.
WARNING: To avoid equipment damage, do not
remove the waterproof tape that is glued on the
MPT waveguide.
H
V
3.2 Remove the solar shield from the MPT by
unscrewing the screws.
3.3 Set the appropriate polarization on the MPT
(see step 4); the connectors must face down.
3.4 Open the four locking hooks on the MPT walls
and slide the MPT on the antenna nose adapter.
3.5 Secure the MPT module with the four hooks.
3.1
5.1 Set the coupler polarization (antenna side) to
match the antenna polarization (same process as
steps 3 and 4: Install and Set MPT polarization), and
then connect.
5.2 Secure the module with the four hooks on the
corresponding brackets.
WARNING: Verify that the indication engraved
on the coupler is directed toward the pole side.
Note: MPT [1+1] configuration is always in horizontal
polarization; this setting does not determine the link
polarization.
1.4
Vertical
7.1 Connect the MPT grounding connector to the nearest grounding plate, using the ground cable
16mm 1AC001060084.
Washer screw and terminal plug are
provided with the MPT.
7 Ground the MPT
1 Contact Support
10 Perform alignment
Horizontal
10.1 Plug the connector on the maintenance port on the
MPT; see (A).
10.2 Plug the banana plugs into the multi-meter to align
the antenna; see (B).
Line A-A represents azimuth tracking path of a properly aligned antenna.
10.3 Adjust the site elevation to the tracking path (line A-A)
and adjust the azimuth to the maximum RSL (lobe number 2).
Light Service Kit for Alignment 3CC52191AAXX
11
1 Install MSS indoor unit
Example MPT-HC installation
All Rights Reserved Alcatel-Lucent 2011 REF: 3DB20024BAAA ICS 01
Install RF coupler for
MPT [1+1]
11.1 For MPT 1+1 configuration with pole mounting
on the left side (only with 3CC10752AAAA), remove
the pre-cut part for freq bands from 11 to 38 GHz.


Kit for Ethernet cable or coaxial cable ( 6,85) 1AD040130004


Kit for coaxial cable ( 10,3) 1AB128500002
Connection to the ground plate
Auto-amalgamating tape is recommended.
Example

11 to 38 Ghz coupler
9 Connect optical cables
9.1 Use optical LC-LC preassembled cable
3CC52170xxxx for MPT optical connections.
Optical LC-LC preassembled cable is available in
different lengths to interconnect MPT to MSS.
9.2 Use coaxial cable with N-to-Ethernet pairs
pigtails on each side (plus RJ45 and R2CT
connectors) for MPT power.
Note: This is a guideline for assembling the R2CT with the RJ45 connector for CAT5e cable. For details
see Best practice and tips MPR R2CT and RJ45 connector and grounding 3FQ 24013 1100 PCZZA.
8.1 Prepare the R2CT connector, insert the CAT5e cable, and insert the RJ45 plug unlocking clip.
Electrical CAT5e
4
5
8
11 10
6
H
6.1 Follow the same process described in steps 3
and 4: Install and Set MPT polarization) and then
connect.
6.2 Install the MPT [2+0] with the OMT.
For an explanation, see the
step indicated by the
numbered circle.
XPIC-RPS cable
8.2 Mount the RJ45 connector using the RJ45 hirose tool.
R2CT connector
1AB150990002
8.3 Hoist the cable using the buckle on the R2CT cap.
8.4 Connect the assembled R2CT to the MPT, mount another RJ45 plug indoors, and verify all cables
and connectors using a cable tester (to avoid short circuit and verify continuity).
8 Assemble and connect electrical connectors
RJ45

connector
RJ45

hirose tool
1AD160490001

or
supplier ref:
HT601/TM21-88P
Contact support
To access online customer support
(OLCS), go to:
http://alcatel-lucent.com/support/
supportredirect.html
For product documentation:
On the OLCS page, select Sign In/Register
(MyAccess) and then log in to OLCS.
For technical support contact information:
On the right side of the OLCS page under Product
Technical Support, select your country from the
Phone and Email Contact Information drop-down
list.
The contact information is displayed.
Service kit cable VDC: 5 4.71 4.12 3.5 2.9 2.3 1.71 1.11 0.59 0.14
RSL (dBm) : -10 -20 -30 -40 -50 -60 -70 -80 -90 -100
Measurement
11.2 For MPT 1+1 configuration with pole mounting
on the right side (only with 3CC10752AAAA),
remove the pre-cut part for freq bands from 11 to 38
GHz.
Remove MPT [1+1] solar shield
Assembled R2CT connector
H
V
Reference
polarization
H
V

You might also like