You are on page 1of 3

25 story

Column size 1x1 m


Beam size 0.55 x 0.9 m

X-direction
Frame 1 Exterior frame
A B C D E F G
steel % Ground story 4.24 4.38 4.64 4.74 4.74 4.64 4.38
Load combination DCON20 DCON22 DCON22 DCON22 DCON22 DCON22 DCON22
steel % 5th story 2.63 2.84 3.07 3.18 3.18 3.07 2.84
Load combination DCON20 DCON22 DCON22 DCON22 DCON22 DCON22 DCON22
steel % 10th story 1.18 1.39 1.52 1.57 1.57 1.52 1.39
Load combination DCON22 DCON22 DCON22 DCON22 DCON22 DCON22 DCON22
steel % 15th story 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26 DCON26 DCON26 DCON26
steel % 20th story 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26 DCON26 DCON26 DCON26
steel % 25th story 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26 DCON26 DCON26 DCON26
Concrete (M3) 4 4 4 4 4 4 4

Frame 2 Interior frame


A B C D E F G
steel % Ground story 5.58 5.15 5.41 5.49 5.49 5.41 5.15
Load combination DCON20 DCON22 DCON22 DCON22 DCON22 DCON22 DCON22
steel % 5th story 3.79 3.5 3.73 3.82 3.82 3.73 3.5
Load combination DCON20 DCON22 DCON22 DCON22 DCON22 DCON22 DCON22
steel % 10th story 1.72 2.03 2.18 2.28 2.28 2.18 2.03
Load combination DCON22 DCON22 DCON22 DCON22 DCON22 DCON22 DCON22
steel % 15th story 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26 DCON26 DCON26 DCON26
steel % 20th story 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26 DCON26 DCON26 DCON26
steel % 25th story 0.8 0.8 0.8 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26 DCON26 DCON26 DCON26
Concrete (M3) 4 4 4 4 4 4 4

Y-direction
Frame A Exterior frame
1 2 3 4
steel % Ground story 4.24 5.58 5.58 4.24
Load combination DCON20 DCON20 DCON20 DCON20
steel % 5th story 2.63 3.79 3.79 2.63
Load combination DCON20 DCON20 DCON20 DCON20
steel % 10th story 1.16 1.72 1.72 1.16
Load combination DCON22 DCON21 DCON21 DCON22
steel % 15th story 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26
steel % 20th story 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26
steel % 25th story 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26
Concrete (M3) 4 4 4 4

Frame B interior frame


1 2 3 4
steel % Ground story 4.38 5.15 5.15 4.38
Load combination DCON22 DCON22 DCON21 DCON21
steel % 5th story 2.84 3.5 3.5 2.84
Load combination DCON22 DCON22 DCON21 DCON21
steel % 10th story 1.39 2.03 2.03 1.39
Load combination DCON22 DCON20 DCON20 DCON21
steel % 15th story 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26
steel % 20th story 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26
steel % 25th story 0.8 0.8 0.8 0.8
Load combination DCON26 DCON26 DCON26 DCON26
Concrete (M3) 4 4 4 4
H
4.24 0 3.3
DCON19 5 1.38
2.63 10 0.8
DCON19 15 0.8
1.18 20
DCON22 25
0.8
DCON26
0.8
DCON26
0.8
DCON26
4

H
5.58
DCON19
3.79
DCON19
1.72
DCON22
0.8
DCON26
0.8
DCON26
0.8
DCON26
4

You might also like