You are on page 1of 17

Chapter No.

Main Structure of AXE


AXE ARCHITECTURE HIERARCHY

System
Level 1

System Level 2

Subsystem Level

Function Block Level


Function Unit Level
GROUP AND CLASSES
ABC REGISTER (EXCERPT)

AX Stored Program Controlled Switching Systems


AXB Exchange Systems for Telex and Data Network.
AXE Public Telephone Exchanges System
AXT Switching Systems for Special Applications\

BF Units Based on Design Module 2.54 MM


BFD Equipped and Unequipped Magazines, Wiring Units
BFE Magazine Groups
BY Packaging Concepts and Structures
BYB Block Packaging Structures.
BZ Power Supply Systems and Installations
BZA Ordinary Full Float Systems
AXE ARCHITECTURE WITH ABC CLASSES

AXE
System Level 1
APZ APT
System Level 2
ANZ ANT
Sub System Level

CNZ CNA
Function Block Level
CAA COA ROF
BFD
Software Hardware
Function Unit Level
AXE 10
A
Systems for Telephone Exchanges,
Private branch Exchanges,and Special Tele Plants.

AX
Stored Program Controlled Switching Systems

AXE
Public Telephone Exchanges System

10 Product No
Main structure of AXE 10
A Manual Exchange in 1890
Switching Lines to/ from
other exchanges
Equipment

Orders Data
APT
Computer APZ
Store Content

An SPC Exchange
The Architecture of control System

Switching Equipment

RP RP RP RP

CP
System Level 1
AXE

APT System APZ


Level 2

TSS SSS OMS Subsystem FMS MCS CPS


Level

Function
LI3 CPU
Block Level

Function Unit Level


LIC (Software or CP-A CP-B
LIR LIU Hardware) Hardware Hardware

AXE Hierarchy Functional Levels


The Structure of Subsystems

Hardware
TSS GSS OMS SSS CCS MTS

Regional Software

TCS TSS GSS OMS SSS CHS SUS OPS CCS MTS NMS

Central Software
System Core
SSS OPS SUS

GSS TCS OMS TSS

CHS CCS
NMS MTS
Hardware LIC

Regional
Program LIR
Software
Data

Central Program
LIU
Software
Data

LI3 Function Block


Hardware

LIC

Regional
Software Program Program
Data Data
LIR

Central Interworking
Software Program Program Program
LIU Data Data Data
Function Function Function
Block LI3 Block X Block Y

Function Block Interworking


Processors in AXE

APT

RP RP RP RP RP

RPB

SP SP CP

CO PRIN
HD
MP
EM-0 EM-1
Extension
EM-15 Modules

EMB
Regional
RP RP Processors

RPB

Central Processors
CP-A CP-B with Maintenance
MAU Unit (MAU)

Inter Working CP-RP-EM


Different CP ’s in AXE

CP Type Subscribers BHCA


APZ 211 40,000 150,000
APZ 212 200,000 800,000
APZ 213 2000 11,000

You might also like