You are on page 1of 2

CA

TEL
TEL
TEL
CA
C
A
CA
CA
CA
T
E
L
TEL
W
C
O
C
O
RA
CO CO
CO
C
O
C
O
CO
CO CO
CO
CO CO
C
O
C
O
C
O
CO
C
O C
O
CO
CO
CO CO CO
CO
CO CO
C
O
C
O
CO
CO
C
O
C
O
CO
WCO
W
C
O
W
C
O
WCO
W
C
O
W
H
W
H
CO CO CO CO
CO
C
O
C
O
1
2
3
4
5
6
A B C D E
TTB
TTB
CTB
CTB
CTB
CTB
TO CATV SERVICE
ENTRANCE
TO TELEPHONE
SERVICE ENTRANCE
TTC
CTB
BEDROOM 1
BEDROOM 2 T&B-2
BEDROOM 3
LIVING AREA
DINNING AREA
KITCHEN
PARENT'S BEDROOM
T&B-1
W.I.C.
HANNAH'S BEDROOM
PORCH
CTB
CTB
1
2
3
4
5
6
A B C D E
LP-7
LP-11
LP-8
LP-18
LP-6
LP-5
PB
LP-13
LP-6
LP-9
LP-12
DINNING AREA
LIVING AREA
PORCH
BEDROOM 3
T&B-2
BEDROOM 2
BEDROOM 1
HALLWAY
KITCHEN
PARENT'S BEDROOM
T&B-1
W.I.C.
HANNAH'S BEDROOM
HALLWAY
1
2
3
4
5
6
A
B C D E
t
u
v
Stuv
n n
m m
S3Wmn
S3Wmn
LP
Sa
Sg
S3Wg Srs
Spq
Sd
Sm
S3e
S3e
Sb
Su
Se
Sa
S3Wg
a
e
c
b
k
q
p
s
m
u
d
g
r
p
Sc
g
l
a
Skl
m
LP-3
LP-1
LP-2
LP-4
BEDROOM 2
BEDROOM 1
HALLWAY
BEDROOM 3
LIVING AREA
PORCH
HANNAH'S BEDROOM
PARENT'S BEDROOM
T&B-1 W.I.C.
DINNING AREA
KITCHEN
PL
ELECTRICAL FIXTURES LEGEND RCP LEGEND
CONVENIENCE OUTLET
WEATHERPROOF OUTLET
RANGE OUTLET
REFRIGERATOR OUTLET
TELEPHONE OUTLET
CABLE TV OUTLET
LIGHT AND POWER PANEL
PINLIGHT
ONE-GANG
SNAP SWITCH
THREE-GANG
SNAP SWITCH
POWER LINE
LIGHTING WIRE LINE
CIRCUIT BREAKER
GROUNDINGS
ENTRANCE
LEGEND:
TWO-GANG
SNAP SWITCH
TWO-WAY
SNAP SWITCH
CO
WCO
RA
REF
TEL
CA
LP
Sa
Sabc
Sab
SW
TELEPHONE TERMINAL BOIX
CATV TERMINAL BOX
TTB
CTB
GENERAL NOTES:
ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE
PROVISION OF THE LATEST APPROVE EDITION OF THE PHILIPPINE ELECTRICAL
CODE, THE LAWS AND ORDINANCES OF THE LOCAL CODE ENFORCING
AUTHORITIES AND REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE COMPANY.
1. SERVICE POWER SHALL BE 230V, SINGLE PHASE, 2-WIRES WITH GROUND, 60Hz SYSTEM.
2. WIRINR METHOD SHALL BE DONE IN PVC CONDUIT FOR LIGHTING, POWER, TELEPHONE
AND AUXILIARY SYSTEM UNLESS OTHERWISE INDICATED IN THE PLAN.
3. SMALLEST BRANCH CIRCUIT WIRE SHALL BE 3.5mm THHN FOR LIGHTING AND POWER
SYSTEM, UNLESS OTHERWISE STATED IN THE PLAN, IN RACEWAY 15mm TRADE SIZE
CONDUIT, WIRE SHALL BE INSULATED FOR 600 VOLTS.
4. ALL BRANCH CIRCUIT HOMERUN SHALL BE INSTALLED AS INDICATED IN THE PLAN.
EXPOSED CIRCUIT RUN SHALL BE PARALLEL TO OR PERPENDICULAR WITH THE BUILDING
LINE AND SUPPORTED BY CONDUIT CLAMPS EVERY 1.5 METERS. DIAGONAL CONDUIT RUN
SHALL NOT BE ACCEPTED.
5. WHENEVER NECESSARY PULLBOX OF PROPER SIZE AND DIMENSION SHALL BE PROVIDED
ALTHOUGH NOT INDICATED IN THE PLAN. ALL JUNCTION BOXES SHALL BE PROVIDED WITH
METAL PLATE COVER.
6. ALL FLUORESCENT LAMP SHALL BE PRE-HEAT TYPE, WITH HIGH POWER FACTOR
BALLAST, CAPACITOR AND SPRING LOADED LAMP HOLDERS.
7. ALL LIGHT-CONTROLLED SWITCHES SHALL BE RATED 15 AMPS, 220 VOLTS AC ONLY,
SWITCHES SHALL BE INSTALLED FOR WITH HORIZONTAL MOTION.
8. ALL PANELBOARD SHALL BE PROVIDED WITH SOLID GROUNDING BUS WITH TERMINALS.
9. ALL METALLIC CONDUIT, CABINET, BOXES AND EQUIPMENT SHALL BE PROPERLY
GROUNDED AND BONDED.
10. ALL MATERIALS TO BE USED SHALL BE NEWAND APPROVED TYPE FOR THE LOCATION
AND PURPOSES.
11. ALL BOXES SHELL BE MADE OF CODE GAUGE STEEL WITH ZINC CHROMATE PROTECTION.
12. ALL RECEPTACLE OUTLET SHALL BE PROPERLY GROUNDED TO THE BOX BY MEANS OF
GROUNDING LUGS.
13. MOUNTING HEIGHT NOT SHOWN ON SCHEDULE ARE AS FOLLOWS:
a. LIGHT-CONTROLLED SWITCHES ---------- 1.40 M. ABOVE FLOOR FINISH AT CENTER
b. DUPLEX CONVENIENCE OUTLET ---------- 0.30 M. ABOVE FLOOR FINISH AT CENTER
c. TELEPHONE OUTLET --------------------------- 0.30 M. ABOVE FLOOR FINISH AT CENTER
d. PANELBOARDS ----------------------------------- 1.40 M. ABOVE FLOOR FINISH AT CENTER
UNLESS OTHERWISE INDICATED BY THE FIELD
CONDITIONS.
14. THE ELECTRICAL CONTRACTOR SHALL SECURE ALL WIRING PERMITS AND ALL FEES
REQUIRED FOR THE WORK AND SHALL FURNISH THE OWNER THROUGH THE ENGINEERS
FINAL CERTIFICATES OF ELECTRICAL INSPECTION AND APPROVAL FROM PROPER
GOVERNMENT AUTHORITIES FOR COMPLETE WORK.
15. THE ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL DRAWING FOR THE
EXACT LOCATION AND MOUNTING HEIGHT OF ALL VISIBLE WIRING DEVICES, FIXTURES AND
THE LIKES.
16. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE UNDER THE DIRECT AND IMMEDIATE
SUPERVISION OF A DULY QUALIFIED LICENSED ELECTRICAL ENGINEER OR MATER
ELECTRICIAN.
ALL MOUNTING HEIGHTS ARE SUBJECT TO THE APPROVAL OF THE ARCHITECT/OWNER.
PROPOSED:
DATE:
SHEET NO.: SHEET CONTENTS:
DRAWN: CHECKED:
OWNER: PROJECT & LOCATION:
PRC No.:
PROJ. NO.: Place:
PTR No.:
Date:
THESE DRAWINGS AND SPECIFICATIONS AND OTHER
CONTRACT DOCUMENTS, DULY SIGNED, STAMPED OR SEALED
AS INSTRUMENT OF SERVICE, ARE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WETHER THE OBJECT
FROM WHICH THEY ARE MADE EXECUTED OR NOT, IT SHALL
BE UNLAWFUL FOR ANY PERSONS TO DUPLICATE OR TO MAKE
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF
AND FOR OTHER PROJECTS OR BUILDING, EXECUTED PARTLY
OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF
ARCHITECT OR AUTHOR OF SAID DOCUMENTS
REPUBLIC ACT 9266 SEC. 33 SEAL
ENGINEER
ADDRESS
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
District/City/Municipality
LOT 152, LO-ONG, CONCEPCION, ILOILO PROVINCE
FABILA RESIDENCE
MS. HANNAH MAE C. FABILA
LIGHTING, CONV. OUTLET, & AUXILIARY LAYOUT,
GENERAL NOTES, & LEGEND
E-1
02/05/14
0
2
/
0
5
/
1
4
F
O
R

B
U
I
L
D
I
N
G

P
E
R
M
I
T
0011
1 : 100 E-1 A-2
AUXILIARY LAYOUT 3
1 : 100 E-1 A-2
CONVENIENCE OUTLET LAYOUT 1
1 : 100 E-1 A-2
LIGHTING LAYOUT 2
2757
1598261
JAN. 02, 2014
PAKIL, LAGUNA
ENGR. PASCUAL P. FERRER
PROFESSIONAL ELECTRICAL ENGINEER
CKT. NO DESCRIPTION
CRK. BREAKER
SIZE OF CONDUCTOR SIZE OF CONDUIT
1 LIGHTING OUTLETS (HANNA'S/T&B/PARENT'S 230 2 - 3.5 mm THHN & 1 - 2.0 mm TWGND 20mm PVC
VOLT
2 LIGHTING OUTLETS (LIVING/DINING/PORCH
4
5
6
CONVENIENCE OUTLETS (KITCHEN)
CONVENIENCE OUTLETS (LIVING/DINING)
20mm PVC
20mm PVC
20mm PVC
20mm PVC
CONVENIENCE OUTLETS (HANNA'S/T&B/PARENTS)
3
7
8
20mm PVC
LIGHTING OUTLETS (GUEST/BEDROOM 1&2/T&B) 20mm PVC
LOAD SCHEDULE AND COMPUTATION
2
9
10
11
12
LIGHTING OUTLETS (KITCHEN/LAUNDRY/UTILITY)
CONVENIENCE OUTLETS (KITCHEN)
CONVENIENCE OUTLETS (BEDROOM 2/T&B)
CONVENIENCE OUTLETS (BEDROOM 1/GUEST)
20mm PVC
20mm PVC
20mm PVC
VA
250
400
250
350
540
720
2160
2160
1080
1440
3000
AMP
1.09
1.74
1.52
2.35
3.13
9.39
1.09
9.39
4.70
6.26
P AF AT
50
WATER HEATER 1 (T&B)
15
16
17
18
19
230
230
230 950
2680
3.13
4.13
20 CONVENIENCE OUTLETS (LAUNDRY AREA/UTILITY)
13
14
20
21
22
WATER HEATER 2 (BEDROOM 2)
ACU 1 HP (HANNA'S ROOM)
ACU 0.75 HP (BEDROOM 2)
ACU 0.75 HP (BEDROOM 1)
ACU 1 HP (HANNA'S ROOM)
ACU 0.75 HP (PARENT'S ROOM)
ACU 0.75 HP (GUEST ROOM)
ELECTRIC RANGE (KITCHEN)
SPARE
SPARE
SPARE
TOTAL
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
230
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
20mm PVC
2 - 3.5 mm THHN & 1 - 2.0 mm TWGND
2 - 3.5 mm THHN & 1 - 2.0 mm TWGND
2 - 3.5 mm THHN & 1 - 2.0 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 5.5 mm THHN & 1 - 5.5 mm TWGND
2 - 5.5 mm THHN & 1 - 5.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 -3.5 mm TWGND
2 - 5.5 mm THHN & 1 - 5.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
2 - 3.5 mm THHN & 1 - 3.5 mm TWGND
- - - - - - - - - - - -
- - - - - - - - - - - -
- - - - - - - - - - - -
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
50
30
20
15
30
20
20
20
20
20
30
30
20
20
20
20
20
20
20
15
15
15
15
3000
720
720
720
720
360
11.65
1.56
13.04
13.04
3.13
3.13
3.13
PANEL:
MOUNTING:
LOCATION:
LP
FLUSH MOUNTED
KITCHEN
MAIN:
USE:
100AT, 2P, 230V, 60HZ. CKT. BREAKER
IN NEMA 1 ENCLOSE
2 - 30mm THHN & 1 - 8.0mm TWGND. WIRE
IN 1 - 25mmDIA. RSC / 32mmDIA. PVC PIPE
22220 96.61
LP = (96.61 A x 0.80 DF) + (1.5 x 4.13 A)
= 83.84 A (USE 100ATAFCB)
L1 L2
2P,15AT
1
2P,15AT
2
2P,15AT
3
2P,15AT
4
2P,20AT
5
2P,20AT
6
2P,20AT
7
2P,20AT
8
2P,20AT
9
2P,20AT
10
2P,30AT
11
2P,30AT
12
2P,20AT
13
2P,20AT
14
2P,20AT
15
2P,20AT
16
2P,20AT
17
2P,30AT
18
2P,20AT
19
2P,15AT
20
2P,20AT
21
2P,30AT
22
LIGHTING OUTLETS
(HANNA'S/T&B/PARENT'S
LIGHTING OUTLETS
(LIVING/DINING/PORCH
CONVENIENCE OUTLETS
(KITCHEN)
CONVENIENCE OUTLETS
(HANNA'S/T&B/PARENTS)
LIGHTING OUTLETS
(GUEST/BEDROOM 1&2/T&B)
CONVENIENCE OUTLETS
(BEDROOM 2/T&B)
WATER HEATER 1 (T&B)
CONVENIENCE OUTLETS
(LAUNDRY AREA/UTILITY)
ACU 0.75 HP (BEDROOM 1)
ACU 1 HP (HANNA'S ROOM)
ACU 0.75 HP (GUEST ROOM)
SPARE
CONVENIENCE OUTLETS
(LIVING/DINING)
LIGHTING OUTLETS
(KITCHEN/LAUNDRY/UTILITY)
CONVENIENCE OUTLETS
(KITCHEN)
CONVENIENCE OUTLETS
(BEDROOM 1/GUEST)
WATER HEATER 2
(BEDROOM 2)
ACU 0.75 HP
(BEDROOM 2)
ACU 0.75 HP
(PARENT'S ROOM)
ELECTRIC RANGE
(KITCHEN)
SPARE
SPARE
2P, 100AT
M
FFL
PANEL LP
(KITCHEN)
2 - 30 MM THHN COPPER &
1 - 8.0 MM TW COPPER IN
1 - 32 MM DIA. PVC 1
7
0
0

(
V
E
R
I
F
Y
)
POWER SERVICE ENTRANCE
1 DIA. 2 WIRE + GROUND, 230 VAC, 60 HZ
2 - 30 MM THHN COPPER &
1 - 8.0 MM TW COPPER IN
1 - 25 MM DIA. PVC
KILOWATT - HOUR METER
PROPOSED:
DATE:
SHEET NO.: SHEET CONTENTS:
DRAWN: CHECKED:
OWNER: PROJECT & LOCATION:
PRC No.:
PROJ. NO.: Place:
PTR No.:
Date:
THESE DRAWINGS AND SPECIFICATIONS AND OTHER
CONTRACT DOCUMENTS, DULY SIGNED, STAMPED OR SEALED
AS INSTRUMENT OF SERVICE, ARE INTELLECTUAL PROPERTY
AND DOCUMENTS OF THE ARCHITECT, WETHER THE OBJECT
FROM WHICH THEY ARE MADE EXECUTED OR NOT, IT SHALL
BE UNLAWFUL FOR ANY PERSONS TO DUPLICATE OR TO MAKE
COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION OF
AND FOR OTHER PROJECTS OR BUILDING, EXECUTED PARTLY
OR IN WHOLE WITHOUT THE WRITTEN CONSENT OF
ARCHITECT OR AUTHOR OF SAID DOCUMENTS
REPUBLIC ACT 9266 SEC. 33 SEAL
ENGINEER
ADDRESS
REPUBLIC OF THE PHILIPPINES
OFFICE OF THE BUILDING OFFICIAL
District/City/Municipality
LOT 152, LO-ONG, CONCEPCION, ILOILO PROVINCE
FABILA RESIDENCE
MS. HANNAH MAE C. FABILA
SCHEDULE OF LOAD, SIGLE LINE DIAGRAM, &
PANEL DETAIL
E-2
02/05/14
0
2
/
0
5
/
1
4
F
O
R

B
U
I
L
D
I
N
G

P
E
R
M
I
T
0011
NTS E-2
PANEL DETAIL (LP) 1
NTS E-2
POWER SINGLE LINE DIAGRAM 2
2757
1598261
JAN. 02, 2014
PAKIL, LAGUNA
ENGR. PASCUAL P. FERRER
PROFESSIONAL ELECTRICAL ENGINEER
ILp= (96.61A x 0.80DF) +1.5 x4.13A = 83.84A Use 100AT100AFCB