You are on page 1of 9

AMP NETCONNECT

Thng Tin K Thu#t Gi'i Php Data Center





AMP NETCONNECT VIETNAM 1
Website : http://ampnetconnect.com.vn





H) TH+NG CP M.NG AMP
NETCONNECT
CHO DATA CENTERS &
STORAGE AREA NETWORKS
(SANs)

Gii Php T#c ') Cao, M+t ') Cao Dnh Cho
Cp ',ng V Cp Quang
AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 2
Website : http://ampnetconnect.com.vn



M0c L0c



MC LC...........................................................................................................................2

GI#I THI&U...................................................................................................................................3

MC TIU C(A H& TH*NG CP M-NG............................................................................................3

H& TH*NG CP QUANG MPO AMP NETCONNECT ..................4

H& TH*NG CP /0NG MRJ21 AMP NETCONNECT. ......................................................................5

K1T N*I T*C /2 CAO. ............................................................................................................6

C3U HNH L4P /5T....................................................................................................6

H& TH*NG AMP NETCONNECT .................................................................................................8

K1T LU6N. ...........................................................................................................................................8
AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 3
Website : http://ampnetconnect.com.vn


GI2I THI)U

N7u c ai ; hi<u bi7t v= n=n t?ng cng nghB truy=n thng th sC ni vEi bGn rHng sJ lLMng cc Nng dOng trong
cc trung tm dQ liBu ; pht tri<n rRt lEn v ngy cng pht tri<n mGnh hFn nQa. Ngy nay cc mGng cp
quang ;ang ;LMc tri<n khai rSng khTp v gi thnh cUa bVng thng truy=n dQ liBu ; gi?m mGnh trn ton cWu
v th7 cc trung tm dQ liBu tX xa (off-site data storage) sC l mSt gi?i php kh? thi trong kinh doanh. Cc
Storage Area Networks (SANs) v Storage Service Providers (SSPs) vEi cc my chU server v cc s?n phZm
lLu trQ dQ liBu kh[ng l\ cUa EMC v Cisco c]ng l nhQng l^a ch_n yu thch cUa ngay c? th` trLbng chNng
khon NASDAQ. Ngay c? nhQng hB thJng mGng c nhn c]ng ;ang xem xt ;7n s^ pht tri<n kinh khUng cc
trung tm lLu trQ dQ liBu c]ng nhL ;i hci v= dung lLMng ;Lbng truy=n dQ liBu cUa h_ cho cc hnh ?nh 3-D,
my qut 3-D y t7, cc b?n vC CAD/CAM, radio frequency identification (RFID) v cc thi7t b` ;o ;Gc phng xG
yu cWu ph?i gi?i quy7t mSt sJ lLMng dQ liBu kh[ng l\ vEi cc my tnh tJc ;S cao ;< phn tch v mGng tJc ;S
cao ;< truy cdp dQ liBu trong thbi gian th^c. Khi cc nh cung cRp cc thi7t b` ;iBn te nhdn ra th` trLbng kh[ng
l\ cUa trung tm dQ liBu (data center) v SAN th h_ hi<u ngay l cc thi7t b` ;iBn te nhL my tnh, card mGng,..
sC l v dOng n7u hB thJng cp mGng khng th< hf trM cho cc Nng dOng tJc ;S cao.

M5C TIU C7A H) TH+NG CP M.NG

HB thJng cp mGng thLbng b` bc qua hohc khng ;LMc ;nh gi cao mhc d chnh hB thJng cp lGi ;LMc
mong ;Mi l c th< se dOng lu nhRt qua nhi=u th7 hB cc thi7t b` ;iBn te khc. MSt quy7t ;`nh ;ng ;Tn v ;Wu
tL chnh xc vo lc ban ;Wu sC ti7t kiBm ;LMc thbi gian, ti=n bGc v nhQng hcng hc trong qu trnh se dOng
c]ng nhL gi?m thi<u kh? nVng ph?i nng cRp hB thJng cp trong tLFng lai. Cp mGng dnh cho cc data
center hohc trung tm lLu trQ (storage area network) khc vEi cRu trc cp mGng truy=n thJng, nhLng vin c
mSt vi y7u tJ thng thLbng.

MOc tiu ;Wu tin cUa hB thJng cp l ph?i vdn chuy<n dng dQ liBu mSt cch nhanh nhRt v [n ;`nh nhRt. MSt
lLMng dQ liBu lEn sC ;LMc truy=n tX cc ngu\n thu tEi cc thi7t b` lLu trQ v ngLMc lGi, khng ai ;LMc php
can thiBp vo hB thJng lm cho gin ;oGn dng thng tin lLu chuy<n trong vng mSt pht hay mSt giy no. Xa
hFn nQa hB thJng sao lLu (back-up) dQ liBu hng ngy ;ang trj nn ph[ bi7n nhL mSt phWn cUa k7 hoGch
phOc h\i dQ liBu sau bRt trTc (disaster-recovery), th7 nn chng ta khng th< bc ra c? ngy chk ;< chuy<n cc
dQ liBu vo cc trung tm lLu trQ (storage area network) do tJc ;S mGng qu chdm.

MOc tiu thN hai cUa hB thJng cp l ph?i ;LMc tri<n khai nhanh nhRt. Cc thi7t b` ;iBn te nHm tGi cc c?ng
nhdn hng khng th< tGo ra thu nhdp. Do ; cc gi?i php l tLjng cho hB thJng cp l ;La ra cc module ;Fn
gi?n trong se dOng, ;LMc ki<m tra m_i thN tX nh my, dm ;ht hng, ;nh gi, thay th7 vEi sJ lLMng nhc v
;LMc k7t nJi vo cc my chU v cc thi7t b` lLu trQ. Thu nhdp rRt cWn thi7t ;hc biBt l giai ;oGn khji ;Wu cc
cng ty khi ph?i chb hng tuWn, hng ngy thdm ch hng gib ;< cc thi7t b` ;LMc lTp ;ht, cRp ;iBn, ;i cp,
v vdn hnh hB thJng. /Fn gi?n ha viBc lTp ;ht sC gi?m bEt s^ cWn thi7t ph?i ;Ru thWu, bo gi v ldp k7
hoGch thu mLEn nhn cng m nhQng viBc ny c th< ph?i mRt hng tuWn, hng thng trLEc.

MOc tiu thN ba cUa hB thJng cp l mdt ;S cao. ViBc lTp ;ht hiBn nay c th< cWn hFn 90m2 khng gian rack
chk ;< ;ht cc thi7t b` lLu trQ. Cc server, rack, v cc patch panel c th< chi7m nhi=u tWng cUa cc ta nh
lEn. Trong khi cc nh cung cRp d`ch vO lLu trQ ch_n phLFng n ;ht cc hB thJng my chU tX xa nhHm gi?m
bEt chi ph thu mLEn bRt ;Sng s?n tGi cc mi trLbng thnh phJ lEn vEi gi qu ;Tt. Cc gi?i php mdt ;S
cao sC lm gi?m t[ng diBn tch sn, khng gian rack v ;\ng thbi qua ; sC lm gi?m chi ph.

HB thJng cp mGng truy=n thJng khng th< l mSt gi?i php tJt nhRt cho mSt data center hohc SAN bji v n
khng th< cung cRp cc khu v^c lm viBc tX xa vEi cc mht mGng (faceplate) hohc cc ;Wu nJi. /i=u ny c
nghna l hB thJng cp ph?i thca mOc tiu thN tL : mSt hB thJng cF sj hG tWng hf trM cc my chU, thi7t b` lLu

AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 4
Website : http://ampnetconnect.com.vn

trQ v cc ;Fn v` xe l trung tm. /hc trLng l cc thi7t b` ;=u k7t nJi thng qua mGng ;i<m tEi ;i<m (point-to-
point network), nhLng cc thi7t b` lLu trQ c th< ;LMc k7t nJi thng qua hB thJng cp phn phJi (distributed
network cabling). Trong m_i trLbng hMp, hB thJng cp ph?i hf trM thi7t k7 ;i<m tEi ;i<m c]ng nhL thi7t k7 cp
phn phJi, hf trM cc kho?ng cch gWn v xa giQa cc thi7t b` v ph?i cung cRp mSt tJc ;S cao cWn thi7t cho
viBc truy=n din c hiBu qu?.

MOc tiu cuJi cng, ;hc biBt quan tr_ng trong giai ;oGn khji ;Wu, l hG thRp chi ph ;Wu tL ban ;Wu. ViBc lTp
;ht cp mGng truy=n thJng l ph?i ;LMc thca thudn v= m_i thN hohc khng c thca thudn g c? v thLbng
;LMc lTp ;ht khi ta nh bTt ;Wu ;LMc xy d^ng hohc trong khi sea chQa nng cRp. Cc ;Lbng cp trOc
(backbone), cp xuyn tWng (riser) v cp ngang (horizontal) tRt c? ;LMc lTp ;ht linh hoGt ty theo hB thJng
mGng. ViBc ;Wu tL tr? trLEc l mSt yu cWu bTt buSc ;< lTp ;ht chk mSt lWn khi ta nh bTt ;Wu ;LMc se dOng.
Xem xt ;7n viBc bTt ;Wu mSt SAN, tuy nhin cng vEi mSt ngu\n ;Wu tL c hGn v viBc cWn ph?i c thu nhdp
ngay ldp tNc. ViBc ;i cp cho ton bS khu v^c tiu bi<u cho mSt s^ ;Wu tL kh[ng l\ m khng c cF hSi hon
lGi cho ;7n khi khu v^c ; hon ton ;LMc lTp cc thi7t b` ;iBn te. NhQng ngLbi se dOng thLbng c xu hLEng
xem viBc chk cWn ;Wu tL mSt phWn hB thJng cp mGng chf no cWn - giJng nhL viBc lTp ;ht cc thi7t b` ;iBn te,
rack v kho?ng khng gian sn, h_ c th< ;Wu tL thm j phWn sau. ViBc ldp k7 hoGch ;Wu tL cp v cc thi7t b`
;iBn te cho mSt th7 hB ;Wu tL, ;hc biBt sC nng cao cF hSi thnh cng cho mSt k7 hoGch lu di.

Tyco Electronics ;La ra hai hB thJng : H9 Th;ng Cp Quang AMP NETCONNECT MPO v H9 Th;ng Cp
>@ng AMP NETCONNECT MRJ21. C? hai hB thJng cung cRp cc thi7t b` thi7t y7u nhRt cho viBc lTp ;ht nhanh
chng, dm dng mang lGi hiBu suRt cao cho mSt cF sj hG tWng mGng cp cUa Data Center v Storage Area
Network.

H) TH+NG CP QUANG AMP NETCONNECT MPO

/Ji vEi cc kho?ng cch giQa cc thi7t b` kho?ng vi feet hay vi trVm mt, hohc ;Ji vEi tJc ;S mGng l 100
Mb/s, 1 Gb/s hay thdm ch 10 Gb/s, H9 Th;ng Cp Quang AMP NETCONNECT MPO l mSt l^a ch_n xuRt
sTc.

Cc thi7t b` module cVn b?n l cha kha cho viBc tri<n khai nhanh chng, lTp ;ht dm dng, ;Wu tL hiBu qu? v
mSt hB thJng mGng linh hoGt. Qui trnh ;i cp c[ ;i<n ko cp, k7t nJi cp, x7p ;ht cc patch panel, ki<m tra
v xe l hcng hc trong viBc lTp ;ht r\i th sea chQa v tRt nhin sC xuRt hiBn rRt nhi=u l do ;< chdm trm v
khng r rng thdm ch c th< gy ra viBc ;[ vp c? d^ n. Cc dy cp trunk cable, cc bS cassette v cc dy
cp assemblies ;LMc bRm sqn l cc thi7t b` module cVn b?n cWn thi7t ;< hon thnh hB thJng mGng.






Cc dy cp trunk cable ;LMc bRm sqn tGi cc nh my
chNa cc ;Wu nJi MPO mdt ;S cao. Mfi ;Wu nJi MPO c
12 ;Wu quang ;Fn, ;Wu nJi loGi cTm-rt c kch thLEc
bHng vEi cc ;Wu nJi SC hay ST. SMi cp mdt ;S cao cUa
;Wu nJi ny c nghna l sMi cp ;LMc bRm sqn ny c th<
;LMc ;ht vo trong cc cable tray hay thdm ch ;LMc ko
tr^c ti7p trong Jng m yu cWu cc ;Lbng Jng lEn hFn.
/LMc ;ht mSt lWn, sMi cp c th< ;LMc k7t nJi vo cc
patch panel, vEi 12 ruSt cp quang chk bHng mSt c bRm
click. Cp MPO trunk cable c sqn cho tRt c? cc ki<u
cp quang v c nhi=u ruSt (c loGi 12 fiber) theo tiu
chuZn v chi=u di ty ch_n. V viBc lTp ;ht v sTp x7p
rack thLbng ;LMc chuZn b` trLEc cho tLFng lai, chi=u
di cc sMi cp thich hMp c th< ;LMc ;ht hng v cRt
giQ cho ;7n khi ngLbi se dOng cWn ;7n.
AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 5
Website : http://ampnetconnect.com.vn

Khi se dOng cp theo ki<u module, ta c th< dng mSt sMi cp di hFn ;< k7t nJi tGm cc thi7t b` vo mGng vo
lc thudn tiBn sMi cp ; c th< ;LMc thay ;[i vo bHng mSt sMi cp c ;S di chnh xc hFn chk trong mSt vi
pht thbi gian down mGng sC l nhc nhRt.














Cc ;Wu nJi MPO ;LMc cTm vo c[ng MPO j pha sau v cc sMi patch cord tiu chuZn c th< k7t nJi vo cc
c[ng mGng cUa thi7t b` ;iBn te. Cc cassette c th< ;LMc ;ht hng v lLu giQ cho ;7n khi cWn se dOng, n
c]ng c sqn cho tRt c? m_i loGi cp quang.


Ta khng cWn ki<m tra ngay c? trong lWn lTp ;ht ;Wu tin v m_i module thi7t b` ; ;LMc bRm v ki<m tra ngay
trong nh my trLEc khi xuRt xLjng. Chk cWn k7t nJi thi7t b` v hB thJng mGng cUa bGn hon tRt. Trong trLbng
hMp sMi cp b` hcng hohc ;Wu nJi b` gy, mfi thi7t b` c th< dm dng ;LMc thay ;[i mSt cch nhanh chng bHng
mSt thi7t b` khc v viBc sea chQa c th< lm j nFi ngTt mGng. Thbi gian down mGng l nhc nhRt.

H) TH+NG CP >BNG AMP NETCONNECT MRJ21

Gi?i php H9 Th;ng Cp >@ng AMP NETCONNECT MRJ21 c mdt ;S cao, hiBu suRt cao, mSt hB thJng
mGng cp ;\ng theo ki<u module. Gi?i php ny cUa Tyco Electronics ; ;LMc thi7t k7 cho cc c[ng Gigabit
Ethernet, c hohc khng c ngu\n ;iBn, trong mSt gi mdt ;S cao. Gi?i php cp 24 pair cng ;Wu nJi hf trM
hon ton cc mi trLbng cTm v chGy bao g\m cc data center, cc zone-cabled office hay open office.

Cng nghB MRJ21 ; pht tri<n tX thi7t k7 ki<u board mGch truy=n thJng thnh gi?i php cc module cho cF
sj hG tWng. Khi se dOng gi?i php ki<u board mGch ny trn mGng switch hay blade server, ;Wu nJi MRJ21 ;La
ra mdt ;S c[ng cao hFn loGi giao diBn RJ45 thng thLbng, n lm gi?m gi thnh cc c[ng trn cc thi7t b`
mGng chU ;Sng. TX vimn c?nh cUa hB thJng cp, HB thJng cp MRJ21 tLFng t^ nhL hB thJng k7t nJi MPO. HB

PhWn lEn cc giao diBn thi7t b` ngy nay nhL MT-RJ, LC,
ST hay SC duplex khng ph?i loGi MPO c nghna l
viBc chuy<n ;[i tX ;Wu nJi 12 fiber MPO l cWn thi7t. Cc
Modular, cassette mGnh mC sC phOc vO cho mOc ;ch
ny. Mfi cassette c kch thLEc nhc v ;LMc thi7t k7 ;<
gTn ngay vo cc patch panel v enclosure hiBn tGi. Trn
cc mht lLng cUa 12-fiber cassette l mSt ;Wu nJi MPO
(24-fiber cassette c 2 ;Wu nJi MPO). Bn trong cc
cassette, mfi sMi quang trong ;Wu nJi MPO ;LMc k7t nJi
tEi mSt c[ng thch hMp j pha trLEc cUa cassette. Trn
mht trLEc cUa cassette c th< l cc c[ng MT-RJ, LC, ST
hohc SC duplex.
Cp Fan-out cable assemblie cung cRp mSt ty
ch_n nhHm bc qua cc patch panel. Se dOng loGi
;Wu nJi MPO, ;Wu trunk cable MPO c th< ;LMc
cTm vo cp MPO fan-out assembly vJn ;LMc
bRm vo cc ;Wu MT-RJ, LC, ST hay SC. Ty
ch_n ny hoGt ;Sng tJt nhRt vEi cc cabinet hay
vEi cc MPO patch panel, nhLng c th< lm
gi?m tnh linh hoGt cUa s^ thay ;\i trong tLFng
lai cho cF sj hG tWng cp mGng.

AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 6
Website : http://ampnetconnect.com.vn

thJng cp MRJ21 c]ng ;LMc module ha, bRm ;Wu v ki<m tra cc thi7t b` tGi nh my ;< c th< ;LMc lTp ;ht
nhanh chng v dm dng.




















KCT N+I T+C >D CAO

ViBc xy d^ng cF sj hG tWng cp vEi cc hB thJng module sC ti7t kiBm thbi gian kho?ng 6 lWn so vEi viBc k7t
nJi cp ;\ng 4 pair thng thLbng, v n sC nhanh hFn rRt nhi=u so vEi viBc bRm ;Wu quang ki<u dng keo r\i
mi bng (epoxy/polish fiber installations). V dO, lTp 8 ;Wu MRJ21mRt chk mSt vi pht so snh vEi mSt vi gib
cho viBc bRm 48 ;Wu RJ45. Nghna l thbi gian se dOng nng ln v gi?m chi ph thbi gian nhn cng.


CEU HNH LFP >GT

C mSt vi cch ;< Nng dOng hB thJng cp ki<u module, tRt c? ty thuSc vo thi7t b` ;Wu cuJi v viBc cWn thi7t
hay yu cWu cUa cc patch panel.


Minh h_a j dLEi cho ta mSt v dO v= ki<u k7t nJi module cVn b?n 48-port Gigabit Ethernet vEi thi7t b` ;Wu cuJi
RJ45 trong mSt data center. K7t nJi ;LMc xy d^ng vEi 1 cp MRJ21 trunk cable, 2 patch panel 48-port 1U v
96 sMi patch cord 4 pair. So snh vEi 48 sMi cp 4 pair, 4 patch panel 24-port 1U v 96 sMi patch cord 4 pair
trong cch lTp ;ht bnh thLbng. Khi danh mOc cc thi7t b` giJng nhau, nn nhE ; l 48 sMi cp 4 pair cWn ph?i
;o cTt, sau ; nhRn vo 96 c[ng vEi 8 sMi con 1 c[ng (768 sMi con). Gi?i php MRJ21 sqn sng cho viBc
truy=n dQ liBu trLEc khi khJi 12 c[ng ;Wu tin ;LMc bRm vEi cp 4 pair. HiBu suRt ti7t kiBm khng gian ;LMc
nhdn ra trong cc patch panel MRJ21 mdt ;S cao.
Cp trunk cable l nhQng sMi cp Powersum 24-pair hiBu suRt
cao ;LMc bRm ;Wu MRJ21 trn mfi ;Wu sMi cp. Ngoi ra cp
MRJ21 break-out c]ng ; c, vEi mSt ;Wu l MRJ21 v ;Wu
cn lGi ;LMc bRm su ;Wu RJ45. NhL vdy mSt sMi cp MRJ21
trunk cable c th< thay th7 cho 6 sMi cp 4 pair vEi kho?ng
khng gian chi7m v tr_ng lLMng nhc nhRt.

Cc ;Wu nJi MRJ21 c th< ;LMc cTm tr^c ti7p vo thi7t b`
;iBn te, tRt nhin n7u thi7t b` ; ;LMc trang b` ;Wu MRJ21,
hohc cTm vo cc panel-mounted cassette mdt ;S cao hay
cTm vo cc c[ng cUa straight hay angled 1U patch panel.
Cc cassette v patch panel cung cRp cc k7t nJi giQa cc
;Wu nJi MRJ21v cc ;Wu cTm RJ45, n c]ng c th< chRp
nhdn cc patch cord 4-pair.

AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 7
Website : http://ampnetconnect.com.vn

CF sj hG tWng cp mGng giQa cc panel se dOng cp module MRJ21 trunk cable nhHm lTp ;ht nhanh chng,
mdt ;S c[ng cao hFn cc panel 24 port 1U truy=n thJng v cho mSt hiBu suRt cao trn cp. V ;y l hB thJng
cp ;\ng thO ;Sng vEi 2 ;Wu nJi (ghi ch: mfi patch panel ;LMc xem nhL mSt ;Wu nJi ;Fn bji v PC board
chuy<n ;[i giao diBn MRJ21 v RJ45), mSt knh truy=n din bao g\m m_i thN ;LMc giEi hGn j 100 mt vEi
t[ng chi=u di l 10 mt cho 2 cp patch cord.

Minh h_a k7 ti7p bi<u dimn m hnh k7t nJi 3 connector vEi cc c[ng thi7t b` MRJ21 vEi kh? nVng ;`nh hnh
ring cho tXng c[ng mGng theo cc Nng dOng ring. Cc d`ch vO cung cRp thLbng dng 1 patch panel ;La ra
cc c[ng switch mdt ;S cao v cc dy thi7t b` (khu v^c A) ;< k7t nJi tEi cc Nng dOng c nhn vEi cc my
chU back-up hay my chU Nng dOng. Trong v dO ny, cF sj hG tWng cp mGng xuRt hiBn giQa patch panel
MRJ21 48-port angled sJ 2 v 3 se dOng cp modular trunk cable. Cc k7t nJi tGi khu v^c B cung cp cc k7t
nJi tX my chU tEi ;Wu cuJi j xa.



V dO thN ba, mSt ;Wu ta dng ;Wu MRJ21 platform nhL phWn mj rSng cUa giao diBn switch, tLFng t^ nhL ;Wu
cp RJ21 breakout vEi nhQng lMi ch cUa ;Wu MRJ21 mdt ;S cao v c?i thiBn hiBu suRt cp mGng. Ki<u cRu trc
ny c]ng ;\ng thbi dm dng chuy<n ;[i thnh thi7t b` n=n MRJ21 cng vEi kh? nVng tch ring tXng c[ng cho
mfi my desktop cc Nng dOng cp ngang khc, bao g\m c? cc wireless access point khng dy v cc thi7t
b` b?o mdt. Xem minh h_a k7 ti7p.







AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 8
Website : http://ampnetconnect.com.vn



Trong v dO ny, cF sj hG tWng cp mGng tnnh cn lGi giQa patch panel RJ45 24-port v outlet. /i=u ny lm
cho c kh? nVng se dOng switch hiBn tGi thm vo cc c[ng mGng chU ;Sng m khng cWn thm cc kho?ng
trJng cho cc thi7t b` ;iBn te. MRJ21 48-port angled patch panels c th< ;LMc thm n7u cWn thi7t.


H) TH+NG AMP NETCONNECT

Tyco Electronics ;La ra tRt c? cc dng AMP NETCONNECT MPO cp quang v MRJ21 trunk cable cp ;\ng
tiu chuZn v cc cassette AMPTRAC-ready, cc enclosure v cable assembly cho viBc lTp ;ht mGng data
center v cc trung tm lLu trQ.

Cp MPO trunk cable c sqn cc loGi 62.5/125, 50/125, XG (850nm LO 50/125) hohc tiu chuZn (phn tn-
khng ;[i) cp quang single-mode vEi sJ li quang ln tEi 72 trong loGi ;Wu 12 fiber. Chi=u di tiu chuZn cp
tX 10 foot ln ;7n 300 feet v cc chi=u di ty ch_n. M_i cassette c sqn cho 50/125, 62.5/125 v cc phin
b?n single-mode ST v SC cassettechRp nhdn mSt loGi ;Wu nJi MPO; cc MT-RJ v LC cassette c sqn loGi
12-fiber (mSt ;u nJi MPO) v 24-fiber (hai ;Wu nJi MPO). Cp MPO fan-out cable assemblies c]ng ; c sqn
cho cc k7t nJi tEi thi7t b`. Cc cRu hnh k7t nJi c]ng ; sqn sng.

Cp MRJ21 assemblies c sqn cc chi=u di tX 0.5 tEi 100 mt ;i trong nh c]ng nhL cp cRu trc. Cc sMi
cp ny c sqn cc loGi tX MRJ21 tEi MRJ21, tEi RJ21, hay tEi ;Wu cTm RJ45. Cc MRJ21 cassette chRp nhdn
2 ;Wu MRJ21 cho cc Nng dOng 12 port 4-pair (nhL Gigabit Ethernet) hay 1 ;Wu MRJ21cho cc Nng dOng 12
port 2-pair (nhL Fast Ethernet). Cc patch panel Straight 1U c loGi 24 port, v 1U angled panel c loGi 48 port.

Khng yu cWu cc rack ;hc biBt cho cc MRJ21 hay MPO cassette. Cc AMP NETCONNECT panel, loGi lTp
;LMc cc AMP NETCONNECT snap-in adapter plate, sC c th< se dOng vEi cc cassette. Cc panel loGi 3, 4,
8, v 12 cassette theo chuZn 19-inch rack, c]ng c sqn cc wall-mount boxe ;< gTn cc adapter plate v cc
cassette.

KCT LUHN

Truyn d$ li'u nhanh. L)p -.t nhanh. R/t d0 dng v2i cc s5n ph7m AMP NETCONNECT modular
t9 Tyco Electronics.
AMP NETCONNECT
Thng Tin K Thu#t Gi'i Php Data Center



AMP NETCONNECT VIETNAM 9
Website : http://ampnetconnect.com.vn



AMP NETCONNECT Chu Thi Bnh DLFng









































Copyright 2006 Tyco Electronics Corporation. All rights reserved.
TYCO, AMP and AMP CETCONNECT are trademarks. http://www.ampnetconnect.com

Australia Sydney
Phone: +61-2-96388132
Fax: +61-2-96388115
http://www.ampnetconnect.com.au/

Australia Melbourne
Phone: +61-3-93895666
Fax: +61-3-93895680
http://www.ampnetconnect.com.au/

China
Phone: +86-21-96999267
http://www.ampnetconnect.com.cn/

Hong Kong
Phone: +852-27388731
Fax: +852-27351625

Indonesia
Phone: +62-21-7976236
+62-21-7976347
Fax: +62-21-7976175

Japan
Phone: +81-44-844-8071
Fax: +81-44-8448732
http://www.ampnetconnect.com/japan/

Korea
Phone: +82-2-34154551
Fax: +82-2-34862416

Malaysia
Phone: +60-3-78053055
Fax: +60-3-78052831

New Zealand Auckland
Phone: +64-9-6344580
Fax: +64-9-6344286
http://www.ampnetconnect.com/nz

New Zealand Wellington
Phone: +64-4-3841495
Fax: +64-4-3842190
http://www.ampnetconnect.com/nz

Pakistan
Phone: +92-51-2870315/16
Fax: +92-51-2277382

Philippines
Phone: +63-2-8480171
Fax: +63-2-8678661

Singapore
Phone: +65-64164595
Fax: +65-64821012

Taiwan
Phone: +886-2-87682788
Fax: +886-2-87681277
+886-2-87683469

Thailand
Phone: +66-2-9550500
Fax: +66-2-9550513
http://www.ampnetconnect.com/thailand

Vietnam
Phone: +84-903-016694
Fax: +84-8-9111076
http://www.ampnetconnect.com.vn

You might also like