Troubleshooting
C13 and C15 On-highway Engines
Media Number -RENR9343-06 Publication Date -01/11/2007 Date Updated -29/11/2007

i02886655
Timer Parameters
SMCS - 1900
"Idle Shutdown Time"
This parameter is the time (minutes) of engine idle before shutting down. The engine will only shut down
if the Engine Control Module (ECM) senses low engine load and no vehicle speed.
This feature is disabled and the engine will idle until the key switch is in the OFF position if this
parameter is programmed to zero minutes.
Note: This feature does not shut down the vehicle's power. The ECM and the vehicle remain powered.
Table 1
Default Minimum Maximum
0 minutes 1 minute 1440 minutes
"Idle Shutdown Timer Maximum RPM"
This parameter resets the "Idle Shutdown Timer" if engine speed goes above the programmed "Idle
Shutdown Timer Maximum RPM". Programming this parameter to 2120 rpm disables this feature. By
disabling this feature, the "Idle Shutdown Timer" cannot be overridden by increasing the engine rpm. If
this parameter is programmed to a value below 2120 rpm and the "PTO Shutdown Timer" is used, the
timer will be reset when the engine rpm exceeds the programmed value.
Table 2
Default Minimum Maximum
2120 rpm 600 rpm 2120 rpm
"Allow Idle Shutdown Override"
This parameter determines if the clutch or the service brake can be used to override the idle shutdown
timer during the driver alert. The driver alert is the last 90 seconds when the check engine lamp begins
flashing. This parameter requires the "Idle Shutdown Time" to be programmed to three or more minutes
for the parameter to be enabled. When the "Idle Shutdown Time" is programmed to zero minutes, this
feature is disabled.
In order to override the timer under the following conditions, depress the clutch or the service brake if
the parameter is programmed to "Outside Temperature Based" or "J1587 Outside Temperature Based"
and the driver alert is activated. Depression of the clutch or the service brake will override the timer:
PDF Created with deskPDF PDF Writer - Trial :: http://www.docudesk.com
Service Information System https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sis...
2 / 4 10.12.2007 11:10
The outside temperature is below the programmed "Minimum Idle Shutdown Outside
Temperature".
The outside temperature is above the" Maximum Idle Shutdown Outside Temperature".
Note: The engine will not shut down when the timer is overridden.
If the outside temperature is between the "Minimum Idle Shutdown Outside Temperature" and the
"Maximum Idle Shutdown Outside Temperature", the timer is not overridden and the engine will shut
down. If the "Outside Temperature Based" option is programmed, an air temperature sensor must be
installed in order to measure the outside temperature.
Table 3
Default Alternative
Yes
No
Outside Temperature Based
(J1587) Outside Temperature Based
"Minimum Idle Shutdown Outside Temp"
This parameter determines the lower outside temperature limit when the "Allow Idle Shutdown
Override" is programmed to one of the following options:
"Outside Temperature Based"
"J1587 Outside Temperature Based"
Table 4
Default Minimum Maximum
49 C (120 F)
-40 C (-40 F) 49 C (120 F)
View Image
PDF Created with deskPDF PDF Writer - Trial :: http://www.docudesk.com
Service Information System https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sis...
3 / 4 10.12.2007 11:10

Illustration 1 g01261767
The "Allow Idle Shutdown Override" is programmed to the "Outside Temperature Based" option or to the "Outside
Temperature Based (J1587)" option.
"Maximum Idle Shutdown Outside Temperature"
This parameter determines the upper outside temperature limit when the "Allow Idle Shutdown
Override" is programmed to one option of the options that follow:
"Outside Temperature Based"
"J1587 Outside Temperature Based"
Illustration 1 indicates that the "Allow Idle Shutdown Override" is allowed in the final 90 seconds of the
timer's countdown. During the final 90 seconds, one of the following conditions must exist in order for
the engine to be shut down:
The outside temperature is below the programmed "Minimum Idle Shutdown Outside
Temperature".
The outside temperature is above the "Maximum Idle Shutdown Outside Temperature".
Table 5
Default Minimum Maximum
49 C (120 F) -40 C (-40 F) 49 C (120 F)
PDF Created with deskPDF PDF Writer - Trial :: http://www.docudesk.com
Service Information System https://sis.cat.com/sisweb/sisweb/techdoc/content.jsp?calledpage=/sis...
4 / 4 10.12.2007 11:10
"A/C Switch Fan-On Time"
Note: Program this parameter only when a normally closed high pressure A/C switch is connected to
P1-41.
The timer prevents excessive cycling of the cooling fan clutch due to successive cycling of the A/C
switch. Programming this parameter to "0" disables the function.
The ECM has a built-in timer. This parameter programs the duration of the timer. Programming depends
on the refrigerant, and the design of the air conditioning system as well as the use of the signal input.
Program the timer to one second when another system also provides a time delay.
This feature requires the "Fan Control Type" to be programmed to any value except "None".
Table 6
Default Minimum Maximum
0 seconds 1 second 600 seconds
"Engine Retarder Delay"
This parameter provides a programmable delay after provisions to turn on the engine retarder or the
engine brake are met.
Table 7
Default Minimum Maximum
0 seconds 0 seconds 3 seconds