Conversion between Metric and English System
E20+ can be set to display in English system. When it’s required to change
setting from metric system to English system, follow the operations as below:
Just press button P until the indicator p is on,input 36987 or 14789 to access X
or Y parameter,change parameters as the table below,and others keep the same.
Gust for KNUTH machine)
Parameter NO. Metric system English system
PAH9 1 3
PAHI8 4 127
PAHI9 1 125
PAH20 a @/25.4
PAH21 b b/25.4
PAU 2 4
PAUI8 + 127
PAUI9 1 125
PAU20 c 25.4
PAU21 d d/25.4
NOTE:
If for metric system PA18 is 2 and PA19 is 1,parameters for English system
must be changed to PAI8=127 and PA19=250.(For both axises)
EXAMPLE:
The original max. value PAH21, e.g. 620.0mm, can be converted into 620 mm/
25.4 = 24.409inch.
The original min: value PAH20, e.g. 10.0 mm, can be converted into
10.0mm/25.4=0.394inch.