SHEET METAL EDGE FLASHING Detail is Applicable

PRIME FLANGE BEFORE STRIPPING for APP, SBS and


Self-Adherd POLYGLASS
POLYGLASS MODIFIED Membranes.
BITUMEN ROOF MEMBRANE SYSTEM

SET FLANGE IN POLYPLUS


FLASHING CEMENT
MULTIPLE-PLY POLYGLASS
MEMBRANE STRIPPING
PLIES

FASTENERS AT
APPROX. 3"
O.C., STAGGERED

GUTTER SPACER
ALTERNATELY SPACED
FROM BRACKETS
ROOF
DECK OPTIONAL: FLEXIBLE
POLYGLASS SA MEMBRANE
WOOD CLOSURE; EXTEND
NAILERS INTO GUTTER

CONTINUOUS CLEAT *
(FASTENED MAX. 12" O.C.)

CONTINUOUS SHEET GUTTER BRACKET


METAL CLOSURE SUPPORT AT 12" TO
FASTENED APPROX. 18" 24" O.C. DEPENDING
[457mm] O.C. UPON CONDITIONS

EXTEND ONE PLY OR SHEET METAL GUTTER


A SEPARATE MEMBRANE
SHEET TO OVERLAY OPTIONAL: TURN-DOWN
METAL CLOSURE

* CONTINUOUS CLEAT IS RECOMMENDED TO BE AT LEAST ONE GAUGE HEAVIER THAN


EDGE FLASHING METAL
NOTES:
1. ATTACH WOOD NAILER TO WALL/DECK IN ACCORDANCE WITH FMRC GUIDLINES, AS PER
SECTION 1-28, REGARDING WINDLOADS TO ROOF SYSTEMS & DECK SECUREMENT.
2. WOOD BLOCKING MAY BE SLOTTED FOR VENTING OF WET-FILL DECKS OR OTHER APPLICABLE
CONSTRUCTIONS
3. THIS DETAIL SHOULD BE USED ONLY WHERE THE DECK IS SUPPORTED BY THE OUTSIDE WALL
4. REFER TO SMACNA RECOMMENDATIONS & DETAILS REGARDING METAL THICKNESS & CLEAT REQUIREMENTS
5. MEMBRANE ENDLAPS MUST BE 6" MINIMUM & FULLY ADHERED AT ALL MEMBRANE IN ALL LOCATIONS
WHERE "FAST LAP" IS NOT PRESENT

NUMBER: PG009
GUTTER DETAIL Polyglass USA Inc.
DATE: Corporate Office and Manufacturing Facility: 150 Lyon Drive, Fernley, Nevada 89408

(ALTERNATE) 05.17.01 Phone (775) 575.6007 - Fax (775) 575.2314 - Toll Free (800) 222-9782
Manufacturing Facilities: 555 Oakridge Road, Humboldt Industrial Park , Hazleton, Pennsylvania 18201
Tel. (570) 384.1230 - Fax (570) 384.3282 - Toll Free (800) 894-4563
621 Snively Avenue, Winterhaven, Florida 33880
REVISION: 02/18/2007 Phone: 863-297-5800 - Fax: 863-297-5858 - Toll Free: 866-802-8017
e-mail: technical@polyglass.com • www.polyglass.com

You might also like