You are on page 1of 19

Date

1/8/2013

CWK

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 1

h
w

tw
(a) Specification
fcu

35 N/mm2

fy

460 N/mm2

fyv

=
=
=

250 N/mm2
50 mm
16 mm

=
=
=

250 mm
3.5 m
3.5 m

tw
H
h
s

20 kN/m3

10 kN/m3

5 kN/m2 (kPa)

(b) Maximum Shear and Moment


Load Factor
Ps + Pw

=
=

142.3 kN/m width

Pq

8.085 kN/m width

VA

=
=

1.4

98.939 kN
115.429 kNm

(b) Main reinforcement


d

176 mm

Ka

0.33

VB

51.491 kN

Date

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 1

M
bd2fcu

=
0.106
Z
= 0.5 + (0.25-K/0.9) d
=
0.863 d
Z should not be more than 0.95d;
Z
=
0.863 d
As'
=
0.0 mm2
As

M
0.87fyZ

1899.2 mm2

As prov

2010.6 mm2

As min

= 0.13bh/100

Sc

K < 0.156

325 mm2

86 mm

(c) Shear Links


=

=
100As
bd
400/d
c

0.562 N/mm2
1.142

###
1/3
1/4
= 0.79(100As/bd) (400/d) /1.25
=

< c

V
bd

0.811 N/mm2

1/8/2013

CWK

1/8/2013

CWK

ed by :

1/8/2013

CWK

ed by :

Provide
T 16

100
b.w.
OK
OK
OK

OK

Date

1/8/2013

CWK

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 2

h
w

tw
(a) Specification
fcu

35 N/mm2

fy

460 N/mm2

fyv

=
=
=

250 N/mm2
50 mm
16 mm

tw
H
h
s

=
=
=

250 mm
4.42 m
3.92 m

20 kN/m3

10 kN/m3

5 kN/m2 (kPa)

(b) Maximum Shear and Moment


Load Factor
Ps + Pw

=
=

106.5 kN/m width

Pq

9.0552 kN/m width

VA

=
=

1.4

80.048 kN
104.596 kNm

(b) Main reinforcement


d

176 mm

Ka

0.33

VB

35.496 kN

Date

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 2

M
bd2fcu

=
0.096
Z
= 0.5 + (0.25-K/0.9) d
=
0.878 d
Z should not be more than 0.95d;
Z
=
0.878 d
As'
=
0 mm2
As

M
0.87fyZ

1691.5 mm2

As prov

2010.6 mm2

As min

= 0.13bh/100

Sc

K < 0.156

325 mm2

86 mm

(c) Shear Links


=

=
100As
bd
400/d
c

0.455 N/mm2
1.142

###
1/3
1/4
= 0.79(100As/bd) (400/d) /1.25
=

< c

V
bd

0.811 N/mm2

1/8/2013

CWK

1/8/2013

CWK

d by :

1/8/2013

CWK

d by :

Provide
T 16

100
b.w.
OK
OK
OK

OK

Date

1/8/2013

CWK

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 3

h
w

tw
(a) Specification
fcu

35 N/mm2

fy

460 N/mm2

fyv

=
=
=

250 N/mm2
50 mm
13 mm

tw
H
h
s

=
=
=

250 mm
4.42 m
2.21 m

20 kN/m3

10 kN/m3

5 kN/m2 (kPa)

(b) Maximum Shear and Moment


Load Factor
Ps + Pw

=
=

56.8 kN/m width

Pq

5.1051 kN/m width

VA

=
=

51.123 kN
37.661 kNm

180.5 mm

1.4

(b) Main reinforcement


d

Ka

0.33

VB

10.735 kN

Date

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 3

M
bd2fcu

=
0.033
Z
= 0.5 + (0.25-K/0.9) d
=
0.962 d
Z should not be more than 0.95d;
Z
=
0.950 d
As'
=
0.0 mm2
As

M
0.87fyZ

548.8 mm2

As prov

663.7 mm2

As min

= 0.13bh/100

Sc

K < 0.156

325 mm2

98 mm

(c) Shear Links


=

=
100As
bd
400/d
c

0.283 N/mm2
0.368

###
1/3
1/4
= 0.79(100As/bd) (400/d) /1.25
=

< c

V
bd

0.552 N/mm2

1/8/2013

CWK

1/8/2013

CWK

d by :

1/8/2013

CWK

d by :

Provide
T 13

200
b.w.
OK
OK
OK

OK

Date

1/8/2013

CWK

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 4

h
w

tw
(a) Specification
fcu

35 N/mm2

fy

460 N/mm2

fyv

=
=
=

250 N/mm2
50 mm
13 mm

=
=
=

250 mm
3m
1.5 m

tw
H
h
s

20 kN/m3

10 kN/m3

5 kN/m2 (kPa)

(b) Maximum Shear and Moment


Load Factor
Ps + Pw

=
=

26.1 kN/m width

Pq

3.465 kN/m width

VA

=
=

24.386 kN
12.193 kNm

180.5 mm

1.4

(b) Main reinforcement


d

Ka

VB

0.33

5.224 kN

Date

Designed by :

JOB NO :

12033/BW

TITLE : Basement Wall Type 4

M
bd2fcu

=
0.011
Z
= 0.5 + (0.25-K/0.9) d
=
0.988 d
Z should not be more than 0.95d;
Z
=
0.950 d
As'
=
0.0 mm2
As

M
0.87fyZ

177.7 mm2

As prov

663.7 mm2

As min

= 0.13bh/100

Sc

K < 0.156

325 mm2

98 mm

(c) Shear Links


=

=
100As
bd
400/d
c

0.135 N/mm2
0.368

###
1/3
1/4
= 0.79(100As/bd) (400/d) /1.25
=

< c

V
bd

0.552 N/mm2

1/8/2013

CWK

1/8/2013

CWK

d by :

1/8/2013

CWK

d by :

Provide
T 13

200
b.w.
OK
OK
OK

OK

Distribution Bar
Main Reinforcement

Summary
BW Type
1
2
3
4

Main Bar
T13-100
T16-100
T13-200
T13-200

Distributiom
T10-200
T10-200
T10-200
T10-200

You might also like