ECONOMIC-B Basic VCZ-02


water heater /

Wasserwrmetauscher
electric heater /

Elektrowrmetauscher
air-only /
ohne
Wasserwrmetauscher
opening heights of up to 4.5 m /

4,5
fr ffnungen
bis Hhe
4,5
m

GRUNDEIGENSCHAFTEN

BASIC FEATURES
- Single capacity line, for opening heights of up to 4.5 m
- 1.0 m, 1.5 m, and 2.0 m lengths
- Three types of electric heaters, water heater, or air-only
version
- Two types of integrated regulation
- Mounting bracket included
- Water heater regulation from control panel (RF)
- 36-month guarantee

- eine
Leistungsreihe,
,
fr
ffnungen

bis
Hhe 4,5
m4,5
- Lngen

1,0m; 1,5m
1,0 ;und
1,52,0
m
2,0
- drei

Typen

der Elektro-,,
Wasserwrmetauscher,
oder
Ausfhrung

ohne Wrmetauscher

- Zwei
Typen
von integrierter
Regelung

-
Wasserwrmetauscher
Regulierung
von Fernbedienpult

(RF)
-

- die
sind Bestandteil der Lieferung.
Montagekonsolen
(RF)
-- Gewhrleistung
36
Monate
36

The ECONOMIC-B Basic air curtains are designed for the


barrier-free separation of two areas with various climatic
conditions. They may also be used for heating. These air
curtains are suitable for installation in smaller shops,
warehouses, foyers of hotels, public offices, and so on. The
air curtain shall be installed indoor in a dry area with
ambient temperatures ranging from 0 C up to +40 C and
relative humidity of up to 80 %. It is designed for conveying
air free of rough dust, grease, chemical fumes, and other
impurities. IP rating of the air curtain is IP 20.
The air curtain project shall always be developed by
the HVAC designer.
The air curtain housing is made of white painted metalplate
(RAL9010). Other RAL-based color may also be provided on
customer's request.

Die
Luftschleier
ECONOMIC-B Basic
Basic dienen

ECONOMIC-B
zum

barrierenlosen
Trennen
von
zwei
Rumen
mit
verschiedenen
klimatischen
Bedingungen,
ggf.
knnen
sie
- ,
zum
Heizen bentzt
werden. Diese
Luftschleier
sind zur

Installation
in kleineren
Eintrittshallen

Geschften,
Lagern,

von
Hotels,
mtern
usw.
gnstig.
Der
Luftschleier
istzum
, , ,
..
Betreib
in
innerer,
trockener
Umgebung
mit
einer

Umlufttemperatur
0 C
bis +40 C, mit
relativer
zwischen

Feuchtigkeit
80+40
% C
und
zum
Transport staubloser,
0von
C

fettloser
auch
keine
chemischen
Dmpfe
oder
80Luft,
% die


sonstige
Verunreinigungen
enthlt
vorgesehen.
Der
, , Luftschleier
die elektrische
Schutzart
. hat

IP
- IP20.
20. Den
Entwurf
Luftschleiers
hat stets
der Projektant
des

von
der
Lufttechnik
und
Heizung
zu
lsen.

Das
Luftschleiergehuse
ist aus einem weilackierten Blech

.
(RAL
9010)
hergestellt.
Auf
Wunsch
kann auch andere

,
Farbe
aus der
Musterkarte
geliefert werden.

RAL
(RAL9010).

RAL.

PRIMARY PARAMETERS

WICHTIGSTE PARAMETER

Air curtains
withPARAMETERS
electric heater are fitted with the
PRIMARY
emergency thermostat with manual reset. The warm-water
exchangers
designed
for the
maximum
operating
Air
curtainsare
with
electric
heater
are fitted
withwater
the
temperaturethermostat
of +100 Cwith
andmanual
maximum
operating
pressure
emergency
reset.
The warm-water
of 1.6 MPa. are designed for the maximum operating water
exchangers
temperature of +100 C and maximum operating pressure
of 1.6 MPa.

Die Luftschleier
mit
Elektrowrmetauscher sind mit einem

Havariethermostat mit manuellem Reset versehen. Die


Warmwasserwrmetauscher
sind fr eine
max. Betriebs

temperatur
des Wassers +100
C und
max. Betriebsdruck

().
1,6 MPa bestimmt.

+100 C
1,6 .

AIR CURTAINS LUFTSCHLEIER

AIR

Produced in EU

026
029

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02


Heater voltage
/current [V/A]

/ [/]

Fan voltage
/current [V/A]

/ [/]

Weight [kg]
[]

6,0

400/8,7

230-240/0,9

18,6

9,0

400/13,0

230-240/0,9

22,7

48,5

12,0

400/17,3

26,9

1300

46,0

9,0

400/13,0

230-240/0,9
230-240/0,9

VCZ02-B-150-F-xx

1900

47,0

14,0

400/20,2

230-240/0,9

24,5

VCZ02-B-200-F-xx

2550

47,5

18,0

400/26,0

230-240/0,9

29,3

VCZ02-B-100-G-xx

1350

47,0

4,5

400/6,5

230-240/0,9

18,6

VCZ02-B-150-G-xx

2000

48,0

6,75

400/9,7

230-240/0,9

22,7

VCZ02-B-200-G-xx

2700

48,5

9,0

400/13,0

230-240/0,9

26,9

1100

44,0

8,67***

230-240/0,9

22,7

VCZ02-B-150-V-xx

1650

44,5

14,31***

230-240/0,9

28,4

VCZ02-B-200-V-xx

2200

46,0

20,34***

230-240/0,9

34,4

VCZ02-B-100-S-xx

1500

49,0

Without heating

230-240/0,9

17,6

230-240/0,9

20,9

230-240/0,9

24,5

Air capacity [m3/h]

[3/]

Noise** [dB(A)]
** [()]

Heater power [kW]

[]

VCZ02-B-100-E-xx

1350

47,0

VCZ02-B-150-E-xx

2000

48,0

VCZ02-B-200-E-xx

2700

VCZ02-B-100-F-xx

Air curtain type


VCZ02-B-100-V-xx

Door height* [m]


* []

4,5


VCZ02-B-150-S-xx

2200

50,0

Without heating

VCZ02-B-200-S-xx

2950

50,5

Without heating

19,7


Limited distance when air flow speed decreases to 2 m/s. Applies to the
highest capacity type under optimum conditions.
** Sound pressure measured 3 m from the air curtain intake.
***At the temperature gradient of 90/70 and temperature of intake air
equal to +18 C.
*

Electric heater parameters



2 /. .
** , 3
.
*** 90/70
+18 C.

Heater power [kW]


[]

Temperature increase* t [C]


* [C]

Air curtain type


Air capacity [m3/h]

[3/]

1st level / 1 .

2nd level / 2 .

1st level / 1 .

2nd level / 2 .

VCZ02-B-100-E-xx

1350

6,0

13,1

VCZ02-B-150-E-xx

2000

9,0

13,3

VCZ02-B-200-E-xx

2700

12,0

13,1

VCZ02-B-100-F-xx

1300

4,5

9,0

10,2

20,4

VCZ02-B-150-F-xx

1900

7,0

14,0

10,9

21,7

VCZ02-B-200-F-xx

2550

9,0

18,0

10,4

20,8

VCZ02-B-100-G-xx

1350

4,5

9,8

VCZ02-B-150-G-xx

2000

6,75

9,9

VCZ02-B-200-G-xx

2700

9,0

9,8

At the maximum air flow and maximum heater power

Water exchanger parameters for water temperature gradient of 60/40 C


60/40 C
Air capacity* [m3/h]

* [3/]

Heater power* [kW]

* []

Outlet temperature [C]


[C]

Water flow [l/s]


[/]

Water pressure loss [kPa]



[]

VCZ02-B-100-V-xx

1100

4,23

30

0,05

0,76

VCZ02-B-150-V-xx

1650

7,00

31

0,08

3,22

VCZ02-B-200-V-xx

2200

9,98

32

0,12

6,03

Air curtain type


Temperature of intake air: +18 C

+18 C

027
030
AIR
CURTAINS

AIR CURTAINS
Produced in EU

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02


Water exchanger parameters for water temperature gradient of 70/50 C
70/50 C
Air capacity* [m3/h]

* [3/]

Heater power* [kW]

* []

Outlet temperature [C]


[C]

Water flow [l/s]


[/]

Water pressure loss [kPa]



[]

VCZ02-B-100-V-xx

1100

5,68

35

0,07

1,29

VCZ02-B-150-V-xx

1650

9,39

36

0,11

4,90

VCZ02-B-200-V-xx

2200

13,37

37

0,16

10,73

Air curtain type


Temperature of intake air: +18 C

+18 C

Water exchanger parameters for water temperature gradient of 80/60 C


80/60 C
Air curtain type

Air capacity* [m3/h]

* [3/]

Heater power* [kW]

* []

Outlet temperature [C]


[C]

Water flow [l/s]


[/]

Water pressure loss [kPa]



[]
1,98

VCZ02-B-100-V-xx

1100

7,16

39

0,09

VCZ02-B-150-V-xx

1650

11,82

41

0,14

6,90

VCZ02-B-200-V-xx

2200

16,82

43

0,20

16,86

Temperature of intake air: +18 C

+18 C

Water exchanger parameters for water temperature gradient of 90/70 C


90/70 C
Air curtain type

Air capacity* [m3/h]

* [3/]

Heater power* [kW]

* []

Outlet temperature [C]


[C]

Water flow [l/s]


[/]

Water pressure loss [kPa]



[]
2,84

VCZ02-B-100-V-xx

1100

8,67

44

0,11

VCZ02-B-150-V-xx

1650

14,31

46

0,17

9,25

VCZ02-B-200-V-xx

2200

20,34

48

0,24

24,15

Temperature of intake air: +18 C

238

+18 C

251

120

G1/2" water inlet and outlet


G1/2

83

L (1006, 1506, 2006)

AIR CURTAINS
AIR

Produced in EU

028
031

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02

52

164

M6

43

INSTALLATION AND ASSEMBLY

57

130

4x

23

G1/2" water inlet and outlet


G1/2

155

- The air curtain shall be installed in a horizontal position


only.
- The air curtain shall be located as close to the top edge of
the doorway as possible, see figure.
- To ensure a correct function it is recommended that the air
curtain overlaps the doorway by 100 mm on both sides.
- Correct operation of the air curtain requires that specified
distances from the surrounding objects are observed, see
figure.
- Position of the heating water and power supply
connections shall be taken into consideration during
installation.
- The air curtain shall be installed using supplied brackets.

-
.
-
,
100
-
.
-


- ,

min 50 mm
50

min 200 mm
200

The power cable designed for connecting the SM remote


controller (230-240 V control voltage) is not included and
shall be provided by a company performing installation of
air curtain.


SM (
230-240 ) ;
,
.

029
032
AIR
CURTAINS

AIR CURTAINS
Produced in EU

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02


CONTROL

The ECONOMIC-B Basic air curtains are controlled by the


remote control. The basic parameters of the controller are
given in table below.

ECONOMIC-B Basic
.

.

WATER HEATER CONTROL

We recommend the following control methods:

1) Basic by throttling
TV1-1/1 thermostatic valve. The valve controls smoothly the
warm water supply into the air curtain depending on the
temperature of air leaving the air curtain. One valve is
required for each air curtain.

1) -
TV1-1/1.

, .
.

2) Economical by splitting (open/closed)


ZV-3 three-way zone valve with a servo drive and TER-P
room thermostat. The valve switches the warm water
supply into the air curtain and back towards the heat source
depending on the temperature of air leaving the air curtain
or depending on the room temperature. One valve is
required for each air curtain. ZV-3 three-way zone valve can
be directly controlled by RF control panel.

2)
(/)
ZV-3
TER-P.

,
,
.
. ZV-3
RF .

3) Precise by mixing
SMU mixing point, OSMU-01-6A mixing point controller,
P12L1000 channel sensor or P10L1000 room sensor. The
mixing system controls smoothly the ratio of supply and
return heating water flowing into the air curtain depending
on the temperature of air leaving the air curtain and/or
depending on the room temperature. One mixing point may
be used for multiple air curtains provided that they have
identical length and that the exchangers are connected in a
parallel arrangement.

3) -
SMU,
OSMU-01-6A
P12L1000 P10L1000.

,
, .

,
.

AIR CURTAINS
AIR

Produced in EU

030
033

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Produced in EU

2..

NO

YES

NO

NO

YES (on air curtain housing)


( )

Power cable (230-240 V)


(230-240 )

Water heater control


Door contact connection



Electric heater aftercooling



Air curtain chaining



Light indication of selected function



Controller-air curtain connection



NO

YES

YES

NO

YES *
*

3 speeds
3

YES

YES

Open/Closed
/

ON/OFF
/

3 speeds
3

Radio signal
Pc

Radio signal
Pc

YES (on air curtain housing)


( )

Radio signal
Pc

YES (on air curtain housing)


( )

YES

YES

NO

2 levels
2 c

3 speeds
3

Manual

Manual

YES - Unlimited (in range of radio signal)


- ( )

YES (on air curtain housing)


( )

NO

YES

NO

NO

3 speeds
3

VCZ-02-B-xxx-F-SM

VCZ-02-B-xxx-E-RF
VCZ-02-B-xxx-G-RF
VCZ-02-B-xxx-V-RF

*
( E,G = ON/OFF, F = 50 % / 100 % /OFF).

Power cable (230-240 V)


(230-240 )

YES (on air curtain housing)


( )

* Electric heater control depends on the air curtain type (E,G version =
ON/OFF, F version = 50 % / 100 % /OFF).

NO

3 speeds
3

Manual

Manual

Manual

Electric heater control


Air capacity control


Control type

VCZ-02-B-xxx-S-RF

VCZ-02-B-xxx-E-SM
VCZ-02-B-xxx-G-SM
VCZ-02-B-xxx-F-SM

VCZ-02-B-xxx-S-SM
VCZ-02-B-xxx-V-SM

Overview of functions and sensor connection


Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02

031
034
AIR
CURTAINS

AIR CURTAINS

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02


ACCESSORIES

Required accessories

Connection cable
Controller for air curtains with the SM control is connected
using common wiring cable (230-240 V control voltage), see
Wiring diagrams chapter. A suitable cross-section of the
cable shall be determined based on the particular
installation conditions. This cable should be delivered
by a company performing the air curtain electrical
wiring.


SM ( 230-240 B ).
.
()
.
,
.

Optional accessories

Thermostatic valve
TV1-1/1 (detailed description on the page
381)
331


TV1-1/1 ( . . 331
381)

Three-way valve with servo drive


ZV-3 (detailed description on the page 327
377)


ZV-3 ( . . 327
377)

Door switch for air curtains fitted with the SM control


DS (detailed description on the page 410)
362

SM
DS ( . . 362
410)

Door switch for air curtains fitted with


the RF control
DK-1 (detailed description on the page
411)
363


RF
DK-1 ( . . 411)
363

Mixing point
SMU-xx-xx (detailed description on the
page 372)
322


SMU-xx-xx ( . . 322
372)

WIRING DIAGRAMS

The recommended cross-section of the main power supply


cables is stated in the Instruction Manual.
All wiring diagrams provided in the technical catalog are
indicative only. When assembling the product, observe
strictly the nameplate ratings as well as directions and
diagrams affixed directly to the product or enclosed to the
product.

() .
,
, .
,
, ,

.

AIR CURTAINS
AIR

Produced in EU

032
035

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02


VCZ-02-B-xxx-V,S-SM

230-240V~, Control /

II III IV

M1 M2

M3

PE

c 3

d 4

L+N+PE
230-240V/50hz

CP-SM-V-4
Control panel

VCZ-02-B-xxx-E,G-SM

Door contact
2A/230-240V

230-240V~, Control /

0 1 2

a 1
f

d 4

e 5

b 2
c 3

DK

a 1

DK

DK

DK

M1

M2 M3

E1

E2

L1

L2

L3

PE

L
S
M1
M2

L1+L2+L3+N+PE
400V/50hz

M3
E1

CP-SM-E1-4

Control panel

Door contact
2A/230-240V

VCZ-02-B-xxx-F-SM

230-240V~, Control /
0 1 2

a 1
f

d 4

e 5

b 2
c 3

DK DK

M1

M2

M3

E1 E2

L1

L2

L3

PE

L
S
M1
M2

L1+L2+L3+N+PE
400V/50hz

M3
E1
E2

CP-SM-E2-4

Control panel

VCZ-02-B-xxx-E,G,F-RF

DK

L1

L2

L3

2A/230-240V

VCZ-02-B-xxx-S-RF

230-240V~, Control /
DK

Door contact

230-240V~, Control /
DK DK

PE

PE

L+N+PE
230-240V/50hz

L1+L2+L3+N+PE
400V/50hz

2A/240V

Door contact

Door contact

2A/230-240V

VCZ-02-B-xxx-V-RF

230-240V~, Control /

Three-wayvalve

ZV3

L
open

DK DK

PE

L open
L
N

L+N+PE
230-240V/50hz
Door contact

2A/230-240V

033
036
AIR
CURTAINS

AIR CURTAINS
Produced in EU

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

ECONOMIC-B Basic VCZ-02


KEY TO CODING


VCZ-02 - B - 150 - E - SM

VCZ-02 - B - 150 - E - SM
SM - Power control
RF - Radio control

SM -
RF -

S - air-only
G - electric heater with reduced power
E - electric heater
F - electric heater with increased power
V - water heater

S -
G -

E -
F -

V -

100 - nominal width 1000 mm


150 - nominal width 1500 mm
200 - nominal width 2000 mm
B - output series

100 - 1000
150 - 1500
200 - 2000

VCZ-02 - air curtain ECONOMIC-B Basic

B -
VCZ-02 -
ECONOMIC-B Basic

AIR CURTAINS
AIR

Produced in EU

034
037

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

Your partner
partner in
inventilation...
ventilation...

DK

BASIC FEATURES
The DK door contact is designed for switching equipment
on/off depending on the door position. The contact is closed
with door in the closed position.

DK

/.

Switching capacity: 30 mA, 12 V

: 30 , 12

WIRING DIAGRAMS

KEY TO CODING


DK-1

DK-1
door contact

REGULATION
REGULATION

Produced in EU

411
363

The company reserves the right of change without previous announcement. 2VV, spol. s r.o.

You might also like