Performance Counter Reference


Version: V3.10.20

ZTE CORPORATION
No. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn

LEGAL INFORMATION
Copyright 2013 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.

Additionally, the contents of this document are protected by

contractual confidentiality obligations.


All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE
CORPORATION or of their respective owners.
This document is provided as is, and all express, implied, or statutory warranties, representations or conditions
are disclaimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose,
title or non-infringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the
use of or reliance on the information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications
covering the subject matter of this document. Except as expressly provided in any written license between ZTE
CORPORATION and its licensee, the user of this document shall not acquire any license to the subject matter
herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
The ultimate right to interpret this product resides in ZTE CORPORATION.

Revision History
Revision NO.

Revision Date

Revision Reason

R1.6

20130925

The following counters have been modified:


C373210422~C373210431,

C373250901,

C373250981,

C373261204,

C373261281,

C373271504,

C373271581,

C373281801,

C373281881,

C373292104,

C373292181,

C373302404,

C373302481,

C373312713,

C373323013,

C373333313,

C373474909,

C373474942,

C373474943,

C373474948,

C373474949,

C373474954,

C373474955,

C373394400,

C373394401,

C373444754,

C373444760,

C373600001,

C373600081,

C373610304,

C373610381,

C373620604,

C373620681,

C373630901,

C373630981,

C373641204,

C373641281,

C373651504,

C373651581,

C373661813,

C373672113,

C373682413,

C373723003,

C373970000, C373970001.
The following counters have been added:
C373220653~C373220655,
C373485133,

C373485123~C373485126,

C373485135~C373485139,

C373485141,

C373485143~C373485147,

C373404450~C373404469,

C373474902~C373474908,

C373474917~C373474925,

C373474984~C373474991,

C373343804~C373343807,

C373394402,

C373414585,

C373424688~C373424691,

SJ-20121224143652-001|20130925(R1.6)

C373444755,

C373414586,
C373444756,

ZTE Proprietary and Confidential

Revision NO.

Revision Date

Revision Reason
C373586700~C373586899,

C373692700~C373692704,

C373723004~C373723009,

C373723011~C373723014,

C373220636,

C373424634~C373424640,

C373424676~C373424687, C373990480~C373990491.
R1.5

20130510

The following counters have been modified:


C373200052,
C373474942,

C373230700~C373230705,
C373474943,

C373474947~C373474949,

C373474953~C373474955,

C373474959,

C373374202~C373374212, C374574202~C374574212.
The following counters have been added:
C373200048,
C373384350,

C373474960~C373474983,
C373384351,

C373733300~C373733303,

C373485112~C373485122.
R1.4

20130328

The following counters have been modified:


C373200060,

C373210200~C373210307,

C373210309,

C373210315,

C373210321,

C373210327,

C373210333,

C373210339,

C373210345,

C373210351,

C373210357,

C373210362~C373210371,

C373220608,

C373220611,

C373220614,

C373250981,

C373261281,

C373271581,

C373281801,

C373281881,

C373292181,

C373302481,

C373312713,

C373312714,

C373323013,

C373323014,

C373333313,

C373333314,

C373505375~C373505392,
C373505481~C373505487,

C373384300~C373384335,
C373505473~C373505479,
C373505490,

C373600001,

C373600081,

C373610382,

C373620681,

C373630901,

C373630981,

C373641281,

C373651581,

C373661813,

C373661814,

C373672113,

C373672114,

C373682413,

C373682414,

C373723003,

C373743403,

C373743404,

C373743421,

C373743422,

C373743510~C373743513,

C373743500~C373743503,
C373930016,

C373930017,

C373930022, C373930023.
The following counters have been added:
C373230701~C373230705,
C373292104,

C373302404,

C373261204,
C373384348,

C373271504,
C373384349,

C373414576~C373414584,

C373424643~C373424646,

C373444761,

C373485181~C373485192,

C373444762,

C373546248~C373546267,

C373556414,

C373566450~C373566503,

C373576600~C373576604,

C373576607~C373576611,

C373576614~C373576618,

Revision NO.

Revision Date

Revision Reason
C373610304,

C373620604,

C373641204,

C373651504,

C373723003, C374624609, C374624611.


R1.3

20121210

The following counters have been modified:


C373200101,

C373505474~C373505488,

C373505491~C373505495,

C373485132,

C373250901,

C373250942,

C373250981,

C373250982,

C373250986,

C373261281,

C373271581,

C373281801,

C373281842,

C373281881,

C373281882,

C373281886,

C373292181,

C373302481,

C373312713,

C373323013,

C373333313,

C373600001,

C373600042,

C373600081,

C373600082,

C373600086,

C373610381,

C373620681,

C373620682,

C373630901,

C373630942,

C373630981,

C373630982,

C373630986,

C373641281,

C373651581,

C373661806,

C373661813,

C373661819,

C373672106,

C373672107,

C373672113,

C373682413,

C373682419,

C373743402,

C373743404, C373743500~C373743509.
R1.2

20121130

The following counters have been modified:


C373200021,
C373200069,

C373200049,
C373200075,

C373200063,

C373200097~C373200103,

C373210512~C373210521,

C373505473~C373505479,

C373505481~C373505487,

C373505489~C373505499,

C373220617,

C373474909,

C373474942~C373474959,

C373474927,
C373485132,

C373474928,
C373250901,

C373250981,

C373261281,

C373261282,

C373271581,

C373271582,

C373281801,

C373281881,

C373292181,

C373292182,

C373302481,

C373312713,

C373323013,

C373333313,

,C373600001,

C373600081,

C373610381,

C373610382,

C373620681,

C373620682,

C373630901,

C373630981,

C373641281,

C373641282,

C373651581,

C373661813,

C373661817~C373661820,

C373672113,

C373682413,

C373682417~C373682420,

C373743400~C373743435,

C373743500~C373743519,

C373343765~C373343791,

C373343796~C373343803,

C373353956~C373353961,
C373374242,
C373444754,

C373374243,

C373364118,

C373364119,

C373434716~C373434740,
C373444757~C373444760,

C373454816~C373454821, C373556400~C373556413.
R1.1

20120815

C373474900 and C373474901 have been added.

R1.0

20120630

First edition.

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Serial Number: SJ-20121224143652-001


Publishing Date: 20130925(R1.6)

Contents
About This Manual ......................................................................................... I
Chapter 1 Statistics of RRC Connection .................................................. 1-1
1.1 RRC Connection Establishment .......................................................................... 1-2
1.1.1 Flow Charts and Sampling Points .............................................................. 1-2
1.1.2 Counter List ............................................................................................. 1-3
1.1.3 Counter Description.................................................................................. 1-3
1.2 RRC Connection Re-establishment ................................................................... 1-15
1.2.1 Flow Charts and Sampling Points ............................................................ 1-15
1.2.2 Counter List ........................................................................................... 1-16
1.2.3 Counter Description................................................................................ 1-18
1.3 RRC Connection Re-configuration..................................................................... 1-32
1.3.1 Flow Charts and Sampling Points ............................................................ 1-32
1.3.2 Counter List ........................................................................................... 1-33
1.3.3 Counter Description................................................................................ 1-33
1.4 RRC Connection Release ................................................................................. 1-35
1.4.1 Flow Charts and Sampling Points ............................................................ 1-35
1.4.2 Counter List ........................................................................................... 1-36
1.4.3 Counter Description................................................................................ 1-36
1.5 RRC Connection Number ................................................................................. 1-44
1.5.1 Flow Charts and Sampling Points ............................................................ 1-44
1.5.2 Counter List ........................................................................................... 1-45
1.5.3 Counter Description................................................................................ 1-45
1.6 RRC Connection Number(PLMN) ...................................................................... 1-49
1.6.1 Flow Charts and Sampling Points ............................................................ 1-49
1.6.2 Counter List ........................................................................................... 1-49
1.6.3 Counter List ........................................................................................... 1-50
1.7 RRC Connection Time ...................................................................................... 1-51
1.7.1 Flow Charts and Sampling Points ............................................................ 1-51
1.7.2 Counter List ........................................................................................... 1-52
1.7.3 Counter Description................................................................................ 1-52

Chapter 2 Statistics of E-RAB ................................................................... 2-1


2.1 Initial E-RAB Setup............................................................................................. 2-2
2.1.1 Flow Charts and Sampling Points .............................................................. 2-2

I
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

2.1.2 Counter List ............................................................................................. 2-3


2.1.3 Counter Description.................................................................................. 2-6
2.2 Additional E-RAB Setup.................................................................................... 2-45
2.2.1 Flow Charts and Sampling Points ............................................................ 2-45
2.2.2 Counter List ........................................................................................... 2-46
2.2.3 Counter Description................................................................................ 2-50
2.3 E-RAB Modification .......................................................................................... 2-87
2.3.1 Flow Charts and Sampling Points ............................................................ 2-87
2.3.2 Counter List ........................................................................................... 2-88
2.3.3 Counter Description................................................................................ 2-91
2.4 E-RAB Release...............................................................................................2-130
2.4.1 Flow Charts and Sampling Points ...........................................................2-130
2.4.2 Counter List ..........................................................................................2-131
2.4.3 Counter Description...............................................................................2-139
2.5 E-RAB Handover.............................................................................................2-225
2.5.1 Flow Charts and Sampling Points ...........................................................2-225
2.5.2 Counter List ..........................................................................................2-226
2.5.3 Counter Description...............................................................................2-228
2.6 E-RAB Activity ................................................................................................2-255
2.6.1 Flow Charts and Sampling Points ...........................................................2-255
2.6.2 Counter List ..........................................................................................2-255
2.6.3 Counter Description...............................................................................2-256
2.7 E-RAB Number ...............................................................................................2-265
2.7.1 Flow Charts and Sampling Points ...........................................................2-265
2.7.2 Counter List ..........................................................................................2-265
2.7.3 Counter Description...............................................................................2-266
2.8 E-RAB Setup Time ..........................................................................................2-280
2.8.1 Flow Charts and Sampling Points ...........................................................2-280
2.8.2 Counter List ..........................................................................................2-281
2.8.3 Counter Description...............................................................................2-281

Chapter 3 Statistics of UE Context ........................................................... 3-1


3.1 UE Context Setup .............................................................................................. 3-2
3.1.1 Flow Charts and Sampling Points .............................................................. 3-2
3.1.2 Counter List ............................................................................................. 3-3
3.1.3 Counter Description.................................................................................. 3-3
3.2 UE Context Modification ..................................................................................... 3-8
3.2.1 Flow Charts and Sampling Points .............................................................. 3-8

II
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

3.2.2 Counter List ............................................................................................. 3-8


3.2.3 Counter Description.................................................................................. 3-9
3.3 UE Context Release ..........................................................................................3-11
3.3.1 Flow Charts and Sampling Points .............................................................3-11
3.3.2 Counter List ........................................................................................... 3-12
3.3.3 Counter Description................................................................................ 3-13
3.4 UE Context for CSFB ....................................................................................... 3-19
3.4.1 Flow Charts and Sampling Points ............................................................ 3-19
3.4.2 Counter List ........................................................................................... 3-19
3.4.3 Counter Description................................................................................ 3-20
3.5 Security Mode.................................................................................................. 3-22
3.5.1 Flow Charts and Sampling Points ............................................................ 3-22
3.5.2 Counter List ........................................................................................... 3-22
3.5.3 Counter Description................................................................................ 3-22

Chapter 4 Statistics of S1/X2-connection ................................................ 4-1


4.1 UE-associated Logical S1-connection.................................................................. 4-1
4.1.1 Flow Charts and Sampling Points .............................................................. 4-1
4.1.2 Counter List ............................................................................................. 4-1
4.1.3 Counter Description.................................................................................. 4-2
4.2 S1 Error Indication.............................................................................................. 4-3
4.2.1 Flow Charts and Sampling points .............................................................. 4-3
4.2.2 Counter List ............................................................................................. 4-3
4.2.3 Counter Description.................................................................................. 4-3

Chapter 5 Statistics of SON....................................................................... 5-1


5.1 MRO ................................................................................................................. 5-1
5.1.1 Flow Charts and Sampling Points .............................................................. 5-1
5.1.2 Counter List ............................................................................................. 5-1
5.1.3 Counter Description.................................................................................. 5-2
5.2 RACH...............................................................................................................5-11
5.2.1 Flow Charts and Sampling Points .............................................................5-11
5.2.2 Counter List ............................................................................................5-11
5.2.3 Counter Description................................................................................ 5-12
5.3 PCI.................................................................................................................. 5-18
5.3.1 Flow Charts and Sampling Points ............................................................ 5-18
5.3.2 Counter List ........................................................................................... 5-18
5.3.3 Counter Description................................................................................ 5-21
5.4 X2 Self Configuration........................................................................................ 5-49
III
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

5.4.1 Flow Charts and Sampling Points ............................................................ 5-49


5.4.2 Counter List ........................................................................................... 5-49
5.4.3 Counter Description................................................................................ 5-49

Chapter 6 Statistics of Cell Congestion ................................................... 6-1


6.1 Cell Congestion.................................................................................................. 6-1
6.1.1 Flow Charts and Sampling Points .............................................................. 6-1
6.1.2 Counter List ............................................................................................. 6-1
6.1.3 Counter Description.................................................................................. 6-2

Chapter 7 Statistics of Service Time ........................................................ 7-1


7.1 Cell Service Time ............................................................................................... 7-1
7.1.1 Flow Charts and Sampling Points .............................................................. 7-1
7.1.2 Counter List ............................................................................................. 7-1
7.1.3 Counter Description.................................................................................. 7-1

Chapter 8 Statistics of Redirection........................................................... 8-1


8.1 LTE-UTRAN Redirection ..................................................................................... 8-1
8.1.1 Flow Charts and Sampling Points .............................................................. 8-1
8.1.2 Counter List ............................................................................................. 8-1
8.1.3 Counter Description.................................................................................. 8-2
8.2 LTE-CDMA Redirection....................................................................................... 8-4
8.2.1 Flow Charts and Sampling Points .............................................................. 8-4
8.2.2 Counter List ............................................................................................. 8-5
8.2.3 Counter Description.................................................................................. 8-5
8.3 LTE-GSM Redirection......................................................................................... 8-7
8.3.1 Flow Charts and Sampling Points .............................................................. 8-7
8.3.2 Counter List ............................................................................................. 8-8
8.3.3 Counter Description.................................................................................. 8-8

Chapter 9 Statistics of Handover .............................................................. 9-1


9.1 Intra-Rat Intra-Freq Handover on Cell .................................................................. 9-2
9.1.1 Intra-eNB Intra-Freq Handover on Cell....................................................... 9-2
9.1.2 Inter-eNB X2 Intra-Freq Handover on Cell.................................................9-11
9.1.3 Inter-eNB S1 Intra-Freq Handover on Cell................................................ 9-25
9.2 Intra-Rat Inter-Freq Handover on Cell ................................................................ 9-38
9.2.1 Intra-eNB Inter-Freq Handover on Cell..................................................... 9-38
9.2.2 Inter-eNB X2 Inter-Freq Handover on Cell................................................ 9-48
9.2.3 Inter-eNB S1 Inter-Freq Handover on Cell................................................ 9-61
9.3 Inter-Rat Handover on Cell ............................................................................... 9-75
9.3.1 LTE-UMTS Handover on Cell .................................................................. 9-75
IV
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

9.3.2 LTE-CDMA Handover on Cell.................................................................. 9-86


9.3.3 LTE-GSM Handover on Cell .................................................................... 9-98
9.4 Handover per Handover Cause on Cell............................................................. 9-110
9.4.1 Handover Based on Covering ................................................................ 9-110
9.4.2 Handover Based on Loadbalance........................................................... 9-115
9.4.3 Handover Based on Other Case.............................................................9-125
9.5 Intra-Rat Intra-Freq Handover on EUtranRelation ..............................................9-137
9.5.1 Intra-eNB Intra-Freq Handover on EUtranRelation...................................9-137
9.5.2 Inter-eNB X2 Intra-Freq Handover on EUtranRelation..............................9-146
9.5.3 Inter-eNB S1 Intra-Freq Handover on EUtranRelation..............................9-160
9.6 Intra-Rat Inter-Freq Handover on EUtranRelation ..............................................9-173
9.6.1 Intra-eNB Inter-Freq Handover on EUtranRelation...................................9-173
9.6.2 Inter-eNB X2 Inter-Freq Handover on EUtranRelation..............................9-183
9.6.3 Inter-eNB S1 Inter-Freq Handover on EUtranRelation..............................9-196
9.7 Inter-Rat Handover on EUtranRelation..............................................................9-210
9.7.1 LTE-UMTS Handover on EUtranRelation ................................................9-210
9.7.2 LTE-CDMA Handover on EUtranRelation................................................9-221
9.7.3 LTE-GSM Handover on EUtranRelation ..................................................9-233
9.8 SRVCC Handover ...........................................................................................9-245
9.8.1 LTE-UTRAN SRVCC Handover..............................................................9-245
9.8.2 LTE-GSM SRVCC Handover..................................................................9-248
9.9 RSRP and RSRQ ...........................................................................................9-250
9.9.1 RSRP and RSRQ of the Serving Cell......................................................9-250
9.9.2 RSRP and RSRQ of the Neighboring Cell ...............................................9-266
9.10 Handover Time..............................................................................................9-281
9.10.1 Flow Charts and Sampling Points ........................................................9-281
9.10.2 Counter List ........................................................................................9-282
9.10.3 Counter Description.............................................................................9-283
9.11 DRX Handover ..............................................................................................9-284
9.11.1 Flow Charts and Sampling Points .........................................................9-284
9.11.2 Counter List.........................................................................................9-284
9.11.3 Counter Description .............................................................................9-285
9.12 GAP Handover ..............................................................................................9-289
9.12.1 Flow Charts and Sampling Points .........................................................9-289
9.12.2 Counter List ........................................................................................9-289
9.12.3 Counter Description.............................................................................9-290

Chapter 10 Statistics of Traffic QoS ....................................................... 10-1


V
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

10.1 Traffic Throughput on Cell ............................................................................... 10-1


10.1.1 PDCP SDU Bitrate ............................................................................... 10-1
10.1.2 PDCP PDU Throughput .......................................................................10-23
10.1.3 RLC PDU Throughput..........................................................................10-51
10.1.4 MAC TB Throughput............................................................................10-80
10.1.5 PHY Throughput .................................................................................10-84
10.1.6 MAC Aggregated Throughput...............................................................10-89
10.1.7 IP Throughput .....................................................................................10-94
10.2 Traffic Delay on Cell ....................................................................................10-121
10.2.1 IP Latency on Cell .............................................................................10-121
10.2.2 PDCP SDU DL Delay on Cell .............................................................10-126
10.2.3 Call Duration Before Drop on Cell.......................................................10-131
10.3 Loss Packet on Cell.....................................................................................10-133
10.3.1 PDCP SDU Loss Packet on Cell.........................................................10-133
10.3.2 PDCP SDU Discard Packet on Cell ....................................................10-144
10.3.3 PDCP SDU Total Number on Cell .......................................................10-149
10.4 User Number on Cell ...................................................................................10-162
10.4.1 Active User Number on Cell ...............................................................10-162
10.4.2 Active State Number on Cell ..............................................................10-180
10.4.3 Category User Number ......................................................................10-183
10.5 RLC PDU Number on Cell............................................................................10-186
10.5.1 RLC PDU Retransmission..................................................................10-186
10.6 Traffic Throughput on Cell(PLMN) ................................................................10-187
10.6.1 PDCP SDU Bitrate ............................................................................10-187
10.6.2 PDCP PDU Throughput .....................................................................10-208
10.6.3 RLC PDU Throughput........................................................................10-237
10.6.4 MAC TB Throughput..........................................................................10-266
10.7 Traffic Delay on Cell(PLMN) .........................................................................10-270
10.7.1 IP Latency on Cell .............................................................................10-270
10.7.2 PDCP SDU DL Delay on Cell .............................................................10-275
10.8 Loss Packet on Cell(PLMN) .........................................................................10-281
10.8.1 PDCP SDU Loss Packet on Cell.........................................................10-281
10.8.2 PDCP SDU Discard Packet on Cell ....................................................10-291
10.8.3 PDCP SDU Total Number on Cell .......................................................10-296
10.9 User Number on Cell(PLMN)........................................................................10-309
10.9.1 Active User Number on Cell ...............................................................10-309
10.9.2 Active State Number on Cell ..............................................................10-328

VI
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources ............................................. 11-1


11.1 DL Transmit Power ..........................................................................................11-2
11.1.1 Flow Charts and Sampling Points ...........................................................11-2
11.1.2 Counter List...........................................................................................11-2
11.1.3 Counter Description ...............................................................................11-3
11.2 Received Signal Strength Indication..................................................................11-4
11.2.1 Flow Charts and Sampling Points ...........................................................11-4
11.2.2 Counter List...........................................................................................11-4
11.2.3 Counter Description ...............................................................................11-4
11.3 Power Headroom.............................................................................................11-5
11.3.1 Flow Charts and Sampling Points ...........................................................11-5
11.3.2 Counter List...........................................................................................11-6
11.3.3 Counter Description ...............................................................................11-6
11.4 PRB Usage ................................................................................................... 11-11
11.4.1 Flow Charts and Sampling Points ......................................................... 11-11
11.4.2 Counter List......................................................................................... 11-11
11.4.3 Counter Description ............................................................................. 11-12
11.5 PRB Usage(PLMN)........................................................................................ 11-28
11.5.1 Flow Charts and Sampling Points ......................................................... 11-28
11.5.2 Counter List......................................................................................... 11-28
11.5.3 Counter Description ............................................................................. 11-28
11.6 SPS .............................................................................................................. 11-30
11.6.1 Flow Charts and Sampling Points ......................................................... 11-30
11.6.2 Counter List......................................................................................... 11-30
11.6.3 Counter Description ............................................................................. 11-30
11.7 SINR............................................................................................................. 11-35
11.7.1 Flow Charts and Sampling Points ......................................................... 11-35
11.7.2 Counter List......................................................................................... 11-35
11.7.3 Counter Description ............................................................................. 11-35
11.8 BLER............................................................................................................ 11-36
11.8.1 Flow Charts and Sampling Points ......................................................... 11-36
11.8.2 Counter List......................................................................................... 11-36
11.8.3 Counter Description ............................................................................. 11-37
11.9 Scheduled User Number ................................................................................ 11-42
11.9.1 Flow Charts and Sampling Points ......................................................... 11-42
11.9.2 Counter List......................................................................................... 11-42
11.9.3 Counter Description ............................................................................. 11-43

VII
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

11.10 Sub-band CQI ............................................................................................. 11-44


11.10.1 Flow Charts and Sampling Points ....................................................... 11-44
11.10.2 Counter List....................................................................................... 11-45
11.10.3 Counter Description ........................................................................... 11-46
11.11 Modulation Scheme ..................................................................................... 11-62
11.11.1 Flow Charts and Sampling Points........................................................ 11-62
11.11.2 Counter List ....................................................................................... 11-62
11.11.3 Counter Description ........................................................................... 11-62
11.12 MIMO Usage ............................................................................................... 11-65
11.12.1 Flow Charts and Sampling Points ....................................................... 11-65
11.12.2 Counter List....................................................................................... 11-65
11.12.3 Counter Description ........................................................................... 11-66
11.13 CCE Aggregation......................................................................................... 11-71
11.13.1 Flow Charts and Sampling Points ....................................................... 11-71
11.13.2 Counter List....................................................................................... 11-72
11.13.3 Counter Description ........................................................................... 11-72
11.14 TA............................................................................................................... 11-74
11.14.1 Flow Charts and Sampling Points ....................................................... 11-74
11.14.2 Counter List....................................................................................... 11-74
11.14.3 Counter Description ........................................................................... 11-75
11.15 Msg2........................................................................................................... 11-81
11.15.1 Flow Charts and Sampling Points ....................................................... 11-81
11.15.2 Counter List....................................................................................... 11-81
11.15.3 Counter Description ........................................................................... 11-81
11.16 NI ............................................................................................................... 11-82
11.16.1 Flow Charts and Sampling Points ....................................................... 11-82
11.16.2 Counter List....................................................................................... 11-82
11.16.3 Counter Description ........................................................................... 11-89
11.17 ICIC .......................................................................................................... 11-169
11.17.1 Flow Charts and Sampling Points ..................................................... 11-169
11.17.2 Counter List..................................................................................... 11-169
11.17.3 Counter Description ......................................................................... 11-171
11.18 TTI Bundling.............................................................................................. 11-197
11.18.1 Flow Charts and Sampling Points ..................................................... 11-197
11.18.2 Counter List..................................................................................... 11-197
11.18.3 Counter Description ......................................................................... 11-197

Chapter 12 Statistics of Paging............................................................... 12-1


VIII
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

12.1 Paging ........................................................................................................... 12-1


12.1.1 Flow Charts and Sampling Points .......................................................... 12-1
12.1.2 Counter List ......................................................................................... 12-1
12.1.3 Counter Description.............................................................................. 12-1

Chapter 13 Statistics of Transport Resources....................................... 13-1


13.1 Throughput on IP Pair..................................................................................... 13-1
13.1.1 Flow Charts and Sampling Points .......................................................... 13-1
13.1.2 Counter List ......................................................................................... 13-1
13.1.3 Counter Description.............................................................................. 13-1
13.2 Vlan Throughput on IP Pair ............................................................................. 13-3
13.2.1 Flow Charts and Sampling Points .......................................................... 13-3
13.2.2 Counter List ......................................................................................... 13-3
13.2.3 Counter Description.............................................................................. 13-4
13.3 Dscp Throughput on IP Pair ............................................................................ 13-6
13.3.1 Flow Charts and Sampling Points .......................................................... 13-6
13.3.2 Counter List ......................................................................................... 13-6
13.3.3 Counter Description.............................................................................. 13-6
13.4 Total Throughput on eNodeB........................................................................... 13-8
13.4.1 Flow Charts and Sampling Points .......................................................... 13-8
13.4.2 Counter List ......................................................................................... 13-8
13.4.3 Counter Description.............................................................................. 13-9
13.5 SCTP Link ....................................................................................................13-20
13.5.1 Flow Charts and Sampling Points .........................................................13-20
13.5.2 Counter List ........................................................................................13-20
13.5.3 Counter Description.............................................................................13-21
13.6 OAM Link......................................................................................................13-21
13.6.1 Flow Charts and Sampling Points .........................................................13-21
13.6.2 Counter List ........................................................................................13-22
13.6.3 Counter Description.............................................................................13-22

Chapter 14 Statistics of System Resources .......................................... 14-1


14.1 CPU Resources ............................................................................................. 14-1
14.1.1 Flow Charts and Sampling Points .......................................................... 14-1
14.1.2 Counter List ......................................................................................... 14-1
14.1.3 Counter Description.............................................................................. 14-1
14.2 Memory Resources ........................................................................................ 14-3
14.2.1 Flow Charts and Sampling Points .......................................................... 14-3
14.2.2 Counter List ......................................................................................... 14-3
IX
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

14.2.3 Counter Description.............................................................................. 14-3

Figures............................................................................................................. I

X
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

About This Manual


Purpose
This manual introduces all performance counters of eNodeB.

Intended Audience
l
l
l

eNodeB deployment engineers


Maintenance engineers
Network management engineers

Prerequisite Skill and Knowledge


To use this document effectively, users should have a general understanding of wireless
telecommunications technology. Familiarity with LTE wireless network and its related
components is helpful.

What Is in This Manual


Chapter

Summary

1, Statistics of RRC Connection

Describes the performance counters of RRC connection

2, Statistics of E-RAB

Describes the performance counters of E-RAB

3, Statistics of UE Context

Describes the performance counters of UE context

4, Statistics of S1/X2-connection

Describes the performance counters of S1/X2-connection

5, Statistics of SON

Describes the performance counters of SON

6, Statistics of Cell Congestion

Describes the performance counters of cell congestion

7, Statistics of Service Time

Describes the performance counters of service time

8, Statistics of Redirection

Describes the performance counters of redirection

9, Statistics of Handover

Describes the performance counters of handover

10, Statistics of Traffic QoS

Describes the performance counters of traffic QoS

11, Statistics of Radio Resources

Describes the performance counters of radio resources

12, Statistics of Paging

Describes the performance counters of paging

13, Statistics of Transport Resources

Describes the performance counters of transport


resources

14, Statistics of System Resources

Describes the performance counters of system resources

I
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

II
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1

Statistics of RRC Connection


Table of Contents
RRC Connection Establishment .................................................................................1-2
RRC Connection Re-establishment ..........................................................................1-15
RRC Connection Re-configuration............................................................................1-32
RRC Connection Release ........................................................................................1-35
RRC Connection Number.........................................................................................1-44
RRC Connection Number(PLMN).............................................................................1-49
RRC Connection Time..............................................................................................1-51

1-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.1 RRC Connection Establishment


1.1.1 Flow Charts and Sampling Points
Figure 1-1 RRC Connection Establishment

l
l
l

l
l

Sampling Point 1: The EUTRAN receives the RRC CONNECTION REQUEST


message from the UE and selects to setup the RRC connection through the CCCH.
Sampling Point 2: The EUTRAN sends the RRC CONNECTION SETUP message to
the UE.
Sampling Point 3: The EUTRAN receives the RRC CONNECTION SETUP
COMPLETE message from the UE, indicating that the RRC connection has been
setup successfully.
Sampling Point 4: The EUTRAN sends the RRC CONNECTION REJECT message
to the UE, indicating that the RRC connection has been set up with failure.
Sampling Point 5: The EUTRAN cann't receive the RRC CONNECTION SETUP and
COMPLETE message from the UE, therefore the timer detects overtime.

1-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373200000

Number of Successful Mt-Access RRC Establishment

C373200001

Number of Mt-Access RRC Establishment Failure due to Timeout

C373200002

Number of Mt-Access RRC Establishment Failure due to ENB Admission


Failure

C373200003

Number of Mt-Access RRC Establishment Failure due to Other Reason

C373200004

Number of Successful Mo-Signalling RRC Establishment

C373200005

Number of Mo-Signalling RRC Establishment Failure due to Timeout

C373200006

Number of Mo-Signalling RRC Establishment Failure due to ENB Admission


Failure

C373200007

Number of Mo-Signalling RRC Establishment Failure due to Other Reason

C373200008

Number of Successful Mo-Data RRC Establishment

10

C373200009

Number of Mo-Data RRC Establishment Failure due to Timeout

11

C373200010

Number of Mo-Data RRC Establishment Failure due to ENB Admission


Failure

12

C373200011

Number of Mo-Data RRC Establishment Failure due to Other Reason

13

C373200012

Number of Successful HighPriorityAccess RRC Establishment

14

C373200013

Number of HighPriorityAccess RRC Establishment Failure due to Timeout

15

C373200014

Number of HighPriorityAccess RRC Establishment Failure due to ENB


Admission Failure

16

C373200015

Number of HighPriorityAccess RRC Establishment Failure due to Other


Reason

17

C373200016

Number of Successful Emergency RRC Establishment

18

C373200017

Number of Emergency RRC Establishment Failure due to Timeout

19

C373200018

Number of Emergency RRC Establishment Failure due to ENB Admission


Failure

20

C373200019

Number of Emergency RRC Establishment Failure due to Other Reason

1.1.3 Counter Description


1.1.3.1 C373200000 Number of Successful Mt-Access RRC Establishment
Definition

The counter is used to count the number of successful RRC establishments


for mt-access.
1-3

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionSetupComplete message


from the UE and the establishmentCause is mt-access.
Sampling Point 3

Explanation

The RRCConnectionSetupComplete message is used to confirm the


successful completion of an RRC connection establishment.The counter
is used to count the number of RRCConnectionSetupComplete message
received by eNodeB from UE, and the RRC establishment cause is
mt-Access.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionSetupComplete message from the UE and the
establishmentCause is mt-access.

1.1.3.2 C373200001 Number of Mt-Access RRC Establishment Failure due to Timeout


Definition

The counter is used to count the number of failed RRC establishment for
mt-access due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionSetupComplete message


expires and the establishmentCause is mt-access.
Sampling Point 5

Explanation

The eNodeB receives the RRCConnectionRequest message from


the UE, then sends the RRCConnectionSetup message to the UE.
While the eNodeB is waiting for the RRCConnectionSetupComplete
message from the UE, the timer expires and then the eNodeB sends the
RRCConnectionRelease message to the UE. The counter is used to count
the number of RRC establishment failures for timeout.

Updated

The counter is incremented by 1 when the timer of waiting for


the RRCConnectionSetupComplete message expires and the
establishmentCause is mt-access.

1-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.1.3.3 C373200002 Number of Mt-Access RRC Establishment Failure due to ENB


Admission Failure
Definition

The counter is used to count the number of failed RRC establishment for
mt-access due to admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs admission failures during RRC Connection


setup procedure and the establishmentCause is mt-access.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is mt-Access. The eNodeB occurs
admission failures during RRC Connection setup procedure, then sends
RRCConnectionReject message to the UE. The counter is used to count
the number of RRC establishment failures for admission failures.

Updated

The counter is incremented by 1 when the eNodeB occurs


admission failures during RRC Connection setup procedure and the
establishmentCause is mt-access.

1.1.3.4 C373200003 Number of Mt-Access RRC Establishment Failure due to Other


Reason
Definition

The counter is used to count the number of failed RRC establishment


for mt-access due to other failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs other failures during RRC Connection setup
procedure and the establishmentCause is mt-access.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is mt-Access. The eNodeB occurs
failures for other reason during RRC Connection setup procedure, then
sends RRCConnectionReject message to the UE. The counter is used to
count the number of RRC establishment failures for other reason.

1-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB occurs other failures


during RRC Connection setup procedure and the establishmentCause is
mt-access.

1.1.3.5 C373200004 Number of Successful Mo-Signalling RRC Establishment


Definition

The counter is used to count the number of successful RRC establishments


for mo-Signalling.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionSetupComplete message


from the UE and the establishmentCause is mo-signalling.
Sampling Point 3

Explanation

The RRCConnectionSetupComplete message is used to confirm the


successful completion of an RRC connection establishment.The counter
is used to count the number of RRCConnectionSetupComplete message
received by eNodeB from UE, and the RRC establishment cause is
mo-Signalling.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionSetupComplete message from the UE and the
establishmentCause is mo-signalling.

1.1.3.6 C373200005 Number of Mo-Signalling RRC Establishment Failure due to


Timeout
Definition

The counter is used to count the number of failed RRC establishment


for mo-Signalling due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionSetupComplete message


expires and the establishmentCause is mo-signalling.
Sampling Point 5

1-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Explanation

The eNodeB receives the RRCConnectionRequest message from the


UE, then sends the RRCConnectionSetup message to the UE. While the
eNodeB is waiting for the RRCConnectionSetupComplete from the UE,
the timer expires and then the eNodeB sends the RRCConnectionRelease
message to the UE. The counter is used to count the number of RRC
establishment failures for timeout.

Updated

The counter is incremented by 1 when the timer of waiting for


the RRCConnectionSetupComplete message expires and the
establishmentCause is mo-signalling.

1.1.3.7 C373200006 Number of Mo-Signalling RRC Establishment Failure due to ENB


Admission Failure
Definition

The counter is used to count the number of failed RRC establishment for
mo-Signalling due to admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs admission failures during RRC Connection


setup procedure and the establishmentCause is mo-signalling.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is mo-Signalling. The eNodeB occurs
admission failures during RRC Connection setup procedure, then sends
RRCConnectionReject message to the UE. The counter is used to count
the number of RRC establishment failures for admission failures.

Updated

The counter is incremented by 1 when the eNodeB occurs


admission failures during RRC Connection setup procedure and the
establishmentCause is mo-signalling.

1.1.3.8 C373200007 Number of Mo-Signalling RRC Establishment Failure due to Other


Reason
Definition

The counter is used to count the number of failed RRC establishment for
mo-Signalling due to other failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
1-7

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB occurs other failures during RRC Connection setup
procedure and the establishmentCause is mo-signalling.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is mo-Signalling. The eNodeB occurs
failures for other reason during RRC Connection setup procedure, then
sends RRCConnectionReject message to the UE. The counter is used to
count the number of RRC establishment failures for other reason.

Updated

The counter is incremented by 1 when the eNodeB occurs failures


for other reason during RRC Connection setup procedure and the
establishmentCause is mo-signalling.

1.1.3.9 C373200008 Number of Successful Mo-Data RRC Establishment


Definition

The counter is used to count the number of successful RRC establishments


for mo-Data.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionSetupComplete message


from the UE and the establishmentCause is mo-Data.
Sampling Point 3.

Explanation

The RRCConnectionSetupComplete message is used to confirm the


successful completion of an RRC connection establishment.The counter
is used to count the number of RRCConnectionSetupComplete message
received by eNodeB from UE, and the RRC establishment cause is
mo-Data.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionSetupComplete message from the UE and the
establishmentCause is mo-Data.

1.1.3.10 C373200009 Number of Mo-Data RRC Establishment Failure due to Timeout


Definition

The counter is used to count the number of failed RRC establishment


for mo-Data due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative
1-8

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionSetupComplete message


expires and the establishmentCause is mo-Data.
Sampling Point 5

Explanation

The eNodeB receives the RRCConnectionRequest message from the


UE, then sends the RRCConnectionSetup message to the UE. While the
eNodeB is waiting for the RRCConnectionSetupComplete from the UE,
the timer expires and then the eNodeB sends the RRCConnectionRelease
message to the UE. The counter is used to count the number of RRC
establishment failures for timeout.

Updated

The counter is incremented by 1 when the timer of waiting for


the RRCConnectionSetupComplete message expires and the
establishmentCause is mo-Data.

1.1.3.11 C373200010 Number of Mo-Data RRC Establishment Failure due to ENB


Admission Failure
Definition

The counter is used to count the number of failed RRC establishment for
mo-Data due to admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs admission failures during RRC Connection


setup procedure and the establishmentCause is mo-Data.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the


UE, and the RRC establishment cause is mo-Data. The eNodeB occurs
admission failures during RRC Connection setup procedure, then sends
RRCConnectionReject message to the UE. The counter is used to count
the number of RRC establishment failures for admission failures.

Updated

The counter is incremented by 1 when the eNodeB occurs


admission failures during RRC Connection setup procedure and the
establishmentCause is mo-Data.

1-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.1.3.12 C373200011 Number of Mo-Data RRC Establishment Failure due to Other


Reason
Definition

The counter is used to count the number of failed RRC establishment


for mo-Data due to other failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs other failures during RRC Connection setup
procedure and the establishmentCause is mo-Data.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the


UE, and the RRC establishment cause is mo-Data. The eNodeB occurs
failures for other reason during RRC Connection setup procedure, then
sends RRCConnectionReject message to the UE. The counter is used to
count the number of RRC establishment failures for other reason.

Updated

The counter is incremented by 1 when the eNodeB occurs other failures


during RRC Connection setup procedure and the establishmentCause
is mo-Data.

1.1.3.13 C373200012 Number of Successful HighPriorityAccess RRC Establishment


Definition

The counter is used to count the number of successful RRC establishments


for highPriorityAccess.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionSetupComplete message


from the UE and the establishmentCause is highPriorityAccess.
Sampling Point 3

Explanation

The RRCConnectionSetupComplete message is used to confirm the


successful completion of an RRC connection establishment.The counter
is used to count the number of RRCConnectionSetupComplete message
received by eNodeB from UE, and the RRC establishment cause is
highPriorityAccess.

1-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionSetupComplete message from the UE and the
establishmentCause is highPriorityAccess.

1.1.3.14 C373200013 Number of HighPriorityAccess RRC Establishment Failure due to


Timeout
Definition

The counter is used to count the number of failed RRC establishment for
highPriorityAccess due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionSetupComplete message


expires and the establishmentCause is highPriorityAccess.
Sampling Point 5

Explanation

The eNodeB receives the RRCConnectionRequest message from the


UE, then sends the RRCConnectionSetup message to the UE. While the
eNodeB is waiting for the RRCConnectionSetupComplete from the UE,
the timer expires and then the eNodeB sends the RRCConnectionRelease
message to the UE. The counter is used to count the number of RRC
establishment failures for timeout.

Updated

The counter is incremented by 1 when the timer of waiting for


the RRCConnectionSetupComplete message expires and the
establishmentCause is highPriorityAccess.

1.1.3.15 C373200014 Number of HighPriorityAccess RRC Establishment Failure due to


ENB Admission Failure
Definition

The counter is used to count the number of failed RRC establishment for
highPriorityAccess due to admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs admission failures during RRC Connection


setup procedure and the establishmentCause is highPriorityAccess.
Sampling Point 4

1-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is highPriorityAccess. The eNodeB
occurs admission failures during RRC Connection setup procedure, then
sends RRCConnectionReject message to the UE. The counter is used to
count the number of RRC establishment failures for admission failures.

Updated

The counter is incremented by 1 when the eNodeB occurs


admission failures during RRC Connection setup procedure and the
establishmentCause is highPriorityAccess.

1.1.3.16 C373200015 Number of HighPriorityAccess RRC Establishment Failure due


to Other Reason
Definition

The counter is used to count the number of failed RRC establishment for
highPriorityAccess due to other failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs other failures during RRC Connection setup
procedure and the establishmentCause is highPriorityAccess.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is highPriorityAccess. The eNodeB
occurs failures for other reason during RRC Connection setup procedure,
then sends RRCConnectionReject message to the UE. The counter is
used to count the number of RRC establishment failures for other reason.

Updated

The counter is incremented by 1 when the eNodeB occurs other failures


during RRC Connection setup procedure and the establishmentCause is
highPriorityAccess.

1.1.3.17 C373200016 Number of Successful Emergency RRC Establishment


Definition

The counter is used to count the number of successful RRC establishments


for emergency.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

1-12
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Sampling Point

When the eNodeB receives the RRCConnectionSetupComplete message


from the UE and the establishmentCause is emergency.
Sampling Point 3

Explanation

The RRCConnectionSetupComplete message is used to confirm the


successful completion of an RRC connection establishment.The counter
is used to count the number of RRCConnectionSetupComplete message
received by eNodeB from UE, and the RRC establishment cause is
emergency.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionSetupComplete message from the UE and the
establishmentCause is emergency.

1.1.3.18 C373200017 Number of Emergency RRC Establishment Failure due to Timeout


Definition

The counter is used to count the number of failed RRC establishment for
emergency due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionSetupComplete message


expires and the establishmentCause is emergency.
Sampling Point 5

Explanation

The eNodeB receives the RRCConnectionRequest message from the


UE, then sends the RRCConnectionSetup message to the UE. While the
eNodeB is waiting for the RRCConnectionSetupComplete from the UE,
the timer expires and then the eNodeB sends the RRCConnectionRelease
message to the UE. The counter is used to count the number of RRC
establishment failures for timeout.

Updated

The counter is incremented by 1 when the timer of waiting for


the RRCConnectionSetupComplete message expires and the
establishmentCause is emergency.

1.1.3.19 C373200018 Number of Emergency RRC Establishment Failure due to ENB


Admission Failure
Definition

The counter is used to count the number of failed RRC establishment for
emergency due to admission failures.

Sampling Interval

Event triggered
1-13

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs admission failures during RRC Connection


setup procedure and the establishmentCause is emergency.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is emergency. The eNodeB occurs
admission failures during RRC Connection setup procedure, then sends
RRCConnectionReject message to the UE. The counter is used to count
the number of RRC establishment failures for admission failures.

Updated

The counter is incremented by 1 when the eNodeB occurs


admission failures during RRC Connection setup procedure and the
establishmentCause is emergency.

1.1.3.20 C373200019 Number of Emergency RRC Establishment Failure due to Other


Reason
Definition

The counter is used to count the number of failed RRC establishment


for emergency due to other failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs other failures during RRC Connection setup
procedure and the establishmentCause is emergency.
Sampling Point 4

Explanation

The eNodeB receives the RRCConnectionRequest message from the UE,


and the RRC establishment cause is emergency. The eNodeB occurs
failures for other reason during RRC Connection setup procedure, then
sends RRCConnectionReject message to the UE. The counter is used to
count the number of RRC establishment failures for other reason.

Updated

The counter is incremented by 1 when the eNodeB occurs other failures


during RRC Connection setup procedure and the establishmentCause is
emergency.

1-14
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.2 RRC Connection Re-establishment


1.2.1 Flow Charts and Sampling Points
Figure 1-2 RRC Connection Re-Establishment

l
l

Sampling Point 1:
The EUTRAN receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE and selects to set up the
RRC connection reestablishment through the CCCH.
Sampling Point 2: The EUTRAN sends the RRC CONNECTION REESTABLISHMENT message to the UE.
Sampling Point 3:
The EUTRAN receives the RRC CONNECTION
REESTABLISHMENT COMPLETE message from the UE, indicating that the RRC
connection reestablishment has been set up successfully.
Sampling Point 4:
The EUTRAN sends the RRC CONNECTION
REESTABLISHMENT REJECT message to the UE, indicating that the RRC
connection reestablishment has been set up with failure.
Sampling Point 5: The EUTRAN cann't receive the RRC CONNECTION
REESTABLISHMENT COMPLETE message from the UE, therefore the timer detects
overtime.

1-15
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 1-3 RRC Connection again Re-Establishment

Sampling Point 6: The EUTRAN again receives the RRC CONNECTION


REESTABLISHMENT COMPLETE message from the UE, when the EUTRAN is
waiting for the RRC CONNECTION REESTABLISHMENT COMPLETE message.

1.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373200060

Number of Successful RRC Connection Re-establishment Triggered by


Handover Failure

C373200061

Number of Handover Failure Triggered RRC Re-establishment Failures due


to RRC Reestablish Complete Timeout

C373200062

Number of Handover Failure Triggered RRC Re-establishment Failures due


to ENB Admission Failure

C373200063

Number of Handover Failure Triggered RRC Re-establishment Failures


due to UE Context Not Found

C373200064

Number of Handover Failure Triggered RRC Re-establishment Failures


due to Continue Re-establishment

C373200065

Number of Handover Failure Triggered RRC Re-establishment Failures


due to Other Reason

C373200066

Number of Successful RRC Connection Re-establishment Triggered by


Reconfig Failure

1-16
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

NO.

Counter

Counter Name

Number
8

C373200067

Number of Reconfig Failure Triggered RRC Re-establishment Failures due


to RRC Reestablish CompleteTimeout

C373200068

Number of Reconfig Failure Triggered RRC Re-establishment Failures due


to ENB Admission Failure

10

C373200069

Number of Reconfig Failure Triggered RRC Re-establishment Failures due


to UE Context Not Found

11

C373200070

Number of Reconfig Failure Triggered RRC Re-establishment Failures due


to Continue Re-establishment

12

C373200071

Number of Reconfig Failure Triggered RRC Re-establishment Failures due


to Other Reason

13

C373200072

Number of Successful RRC Connection Re-establishment Triggered by


Other

14

C373200073

Number of Other Triggered RRC Re-establishment Failures due to RRC


Reestablish CompleteTimeout

15

C373200074

Number of Other Triggered RRC Re-establishment Failures due to ENB


Admission Failure

16

C373200075

Number of Other Triggered RRC Re-establishment Failures due to UE


Context Not Found

17

C373200076

Number of Other Triggered RRC Re-establishment Failures due to Continue


Re-establishment

18

C373200077

Number of Other Triggered RRC Re-establishment Failures due to Other


Reason

19

C373200097

Number of Inter-RAT Successful RRC Connection Re-establishment


Triggerd by Handover Failure

20

C373200098

Number of Inter-RAT Handover Failure Triggered RRC Re-establishment


Failures due to RRC Reestablish Complete Timeout

21

C373200099

Number of Inter-RAT Handover Failure Triggered RRC Re-establishment


Failures due to ENB Admission Failure

22

C373200100

Number of Inter-RAT Handover Failure Triggered RRC Re-establishment


Failures due to UE Context Not Found

23

C373200101

Number of Inter-RAT Handover Failure Triggered RRC Re-establishment


Failures due to Continue Re-establishment

24

C373200102

Number of Inter-RAT Handover Failure Triggered RRC Re-establishment


Failures due to Other Reason

25

C373200103

Number of Inter-RAT RRC Connection Re-establishment Request Triggered


by Handover Failure

1-17
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.2.3 Counter Description


1.2.3.1 C373200060 Number of Successful RRC Connection Re-establishment
Triggered by Handover Failure
Definition

The counter is used to count the number of successful RRC connection


re-establishments for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentComplete


message from the UE, and the ReestablishmentCause is handover failures.
Sampling Point 3

Explanation

Receipt by the eNodeB of a RRCConnectionReestablishmentComplete


message following a RRCConnectionReestablishmentRequest
in which ReestablishmentCause is handoverfailures. Each
RRCConnectionReestablishmentComplete message received is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentComplete message from the UE and the
ReestablishmentCause is handover failures.

1.2.3.2 C373200061 Number of Handover Failure Triggered RRC Re-establishment


Failures due to RRC Reestablish Complete Timeout
Definition

The counter is used to count the number of RRC re-establishment failures


due to timeout,and the ReestablishmentCause is handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionReestablishmentComplete


message expires,and the ReestablishmentCause is handoverfailures.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReestablishmentComplete message not received by the eNodeB and the ReestablishmentCause
is handoverfailures. Each failed RRC connection re-establishment is
added to the counter.

1-18
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Updated

The counter is incremented by 1 when the eNodeB's waiting for


the RRCConnectionReestablishmentComplete timer expires,and the
ReestablishmentCause is handoverfailures.

1.2.3.3 C373200062 Number of Handover Failure Triggered RRC Re-establishment


Failures due to ENB Admission Failure
Definition

The counter is used to count the number of RRC re-establishment


failures due to admission failure,and the ReestablishmentCause is
handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to admission failures, and the
ReestablishmentCause is handoverfailures.
Sampling Point 4

Explanation

For admission failures, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
handoverfailures.Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due to
admission failures, and the ReestablishmentCause is handoverfailures.

1.2.3.4 C373200063 Number of Handover Failure Triggered RRC Re-establishment


Failures due to UE Context Not Found
Definition

The counter is used to count the number of RRC re-establishment failures


due to unknown UE identification,and the ReestablishmentCause is
handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

1-19
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to unknown UE identification,and the
ReestablishmentCause is handoverfailures.
Sampling Point 4

Explanation

For not finding UE context, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
handoverfailures.Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due to no
finding the UE context,and the ReestablishmentCause is handoverfailures.

1.2.3.5 C373200064 Number of Handover Failure Triggered RRC Re-establishment


Failures due to Continue Re-establishment
Definition

The counter is used to count the number of RRC re-establishment


failures due to again receiving Reestablishment message,and the
ReestablishmentCause is handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to again receiving the RRCConnectionReestablishmentRequest
message,and the ReestablishmentCause is handoverfailures.
Sampling Point 6.

Explanation

For again reestablishment, the eNodeB sends an RRCConnectionRelease


message to the UE and the ReestablishmentCause is handoverfailures.Each failed RRC connection re-establishment is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE due to again receiving
the RRCConnectionReestablishmentRequest message,and the
ReestablishmentCause is handoverfailures.

1.2.3.6 C373200065 Number of Handover Failure Triggered RRC Re-establishment


Failures due to Other Reason
Definition

The counter is used to count the number of RRC re-establishment failures


due to other reason,and the ReestablishmentCause is handoverfailures.

1-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the RRC Connection Re-establishment failures


due to other reason,and the ReestablishmentCause is handoverfailures.

Explanation

For other reason, the eNodeB sends an RRCConnectionRelease message


to the UE and the ReestablishmentCause is handoverfailures.Each failed
RRC connection re-establishment is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB occurs the RRC


Connection Re-establishment failures due to other reason,and the
ReestablishmentCause is handoverfailures.

1.2.3.7 C373200066 Number of Successful RRC Connection Re-establishment


Triggered by Reconfig Failure
Definition

The counter is used to count the number of successful RRC connection


re-establishments for reconfigurationfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentComplete


message from the UE,and the ReestablishmentCause is
reconfigurationfailures.
Sampling Point 3

Explanation

Receipt by the eNodeB of a RRCConnectionReestablishmentComplete


message following a RRCConnectionReestablishmentRequest
in which ReestablishmentCause is reconfigurationfailures. Each
RRCConnectionReestablishmentComplete message received is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentComplete message from the UE, and the
ReestablishmentCause is reconfigurationfailures.

1-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.2.3.8 C373200067 Number of Reconfig Failure Triggered RRC Re-establishment


Failures due to RRC Reestablish CompleteTimeout
Definition

The counter is used to count the number of RRC re-establishment failures


due to timeout,and the ReestablishmentCause is reconfigurationfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionReestablishmentComplete


message expires,and the ReestablishmentCause is reconfigurationfailures.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReestablishmentComplete message not received by the eNodeB and the ReestablishmentCause
is reconfigurationfailures. Each failed RRC connection re-establishment is
added to the counter.

Updated

The counter is incremented by 1 when the eNodeB's waiting for


the RRCConnectionReestablishmentComplete timer expires,and the
ReestablishmentCause is reconfigurationfailures.

1.2.3.9 C373200068 Number of Reconfig Failure Triggered RRC Re-establishment


Failures due to ENB Admission Failure
Definition

The counter is used to count the number of RRC re-establishment


failures due to admission failure,and the ReestablishmentCause is
reconfigurationfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to admission failures, and the
ReestablishmentCause is reconfigurationfailures.
Sampling Point 4

Explanation

For admission failures, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
reconfigurationfailures.Each failed RRC connection re-establishment is
added to the counter.

1-22
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE
due to admission failures, and the ReestablishmentCause is
reconfigurationfailures.

1.2.3.10 C373200069 Number of Reconfig Failure Triggered RRC Re-establishment


Failures due to UE Context Not Found
Definition

The counter is used to count the number of RRC re-establishment failures


due to unknown UE identification,and the ReestablishmentCause is
reconfigurationfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to unknown UE identification,and the
ReestablishmentCause is reconfigurationfailures.
Sampling Point 4

Explanation

For not finding UE context, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
reconfigurationfailures.Each failed RRC connection re-establishment is
added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due
to no finding the UE context,and the ReestablishmentCause is
reconfigurationfailures.

1.2.3.11 C373200070 Number of Reconfig Failure Triggered RRC Re-establishment


Failures due to Continue Re-establishment
Definition

The counter is used to count the number of RRC re-establishment


failures due to again receiving Reestablishment message,and the
ReestablishmentCause is reconfigurationfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

1-23
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to again receiving the RRCConnectionReestablishmentRequest
message,and the ReestablishmentCause is reconfigurationfailures.
Sampling Point 6

Explanation

For again reestablishment, the eNodeB sends an RRCConnectionRelease


message to the UE and the ReestablishmentCause is reconfigurationfailures.Each failed RRC connection re-establishment is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE due to again receiving
the RRCConnectionReestablishmentRequest message,and the
ReestablishmentCause is reconfigurationfailures.

1.2.3.12 C373200071 Number of Reconfig Failure Triggered RRC Re-establishment


Failures due to Other Reason
Definition

The counter is used to count the number of RRC re-establishment


failures due to other reason,and the ReestablishmentCause is
reconfigurationfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the RRC Connection Re-establishment


failures due to other reason,and the ReestablishmentCause is
reconfigurationfailures.

Explanation

For other reason, the eNodeB sends an RRCConnectionRelease message


to the UE and the ReestablishmentCause is reconfigurationfailures.Each
failed RRC connection re-establishment is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB occurs the RRC


Connection Re-establishment failures due to other reason,and the
ReestablishmentCause is reconfigurationfailures.

1.2.3.13 C373200072 Number of Successful RRC Connection Re-establishment


Triggered by Other
Definition

The counter is used to count the number of successful RRC connection


re-establishments for otherfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative
1-24

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentComplete


message from the UE,and the ReestablishmentCause is otherfailures.
Sampling Point 3

Explanation

Receipt by the eNodeB of a RRCConnectionReestablishmentComplete


message following a RRCConnectionReestablishmentRequest
in which ReestablishmentCause is otherfailures. Each
RRCConnectionReestablishmentComplete message received is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentComplete message from the UE and the
ReestablishmentCause is otherfailures.

1.2.3.14 C373200073 Number of Other Triggered RRC Re-establishment Failures due


to RRC Reestablish CompleteTimeout
Definition

The counter is used to count the number of RRC re-establishment failures


due to timeout,and the ReestablishmentCause is otherfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionReestablishmentComplete


message expires,and the ReestablishmentCause is otherfailures.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReestablishmentComplete message not received by the eNodeB and the ReestablishmentCause
is otherfailures. Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB's waiting for


the RRCConnectionReestablishmentComplete timer expires,and the
ReestablishmentCause is otherfailures.

1.2.3.15 C373200074 Number of Other Triggered RRC Re-establishment Failures due


to ENB Admission Failure
Definition

The counter is used to count the number of RRC re-establishment failures


due to admission failure,and the ReestablishmentCause is otherfailures.
1-25

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to admission failures, and the
ReestablishmentCause is otherfailures.
Sampling Point 4

Explanation

For admission failures, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
otherfailures.Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due to
admission failures, and the ReestablishmentCause is otherfailures.

1.2.3.16 C373200075 Number of Other Triggered RRC Re-establishment Failures due


to UE Context Not Found
Definition

The counter is used to count the number of RRC re-establishment failures


due to unknown UE identification,and the ReestablishmentCause is
otherfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to unknown UE identification,and the
ReestablishmentCause is otherfailures.
Sampling Point 4

Explanation

For not finding UE context, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
otherfailures.Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due to no
finding the UE context,and the ReestablishmentCause is otherfailures.

1-26
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.2.3.17 C373200076 Number of Other Triggered RRC Re-establishment Failures due


to Continue Re-establishment
Definition

The counter is used to count the number of RRC re-establishment


failures due to again receiving Reestablishment message,and the
ReestablishmentCause is otherfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to again receiving the RRCConnectionReestablishmentRequest
message,and the ReestablishmentCause is otherfailures.
Sampling Point 6.

Explanation

For again reestablishment, the eNodeB sends an RRCConnectionRelease


message to the UE and the ReestablishmentCause is otherfailures.Each
failed RRC connection re-establishment is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE due to again receiving
the RRCConnectionReestablishmentRequest message,and the
ReestablishmentCause is otherfailures.

1.2.3.18 C373200077 Number of Other Triggered RRC Re-establishment Failures due


to Other Reason
Definition

The counter is used to count the number of RRC re-establishment failures


due to other reason,and the ReestablishmentCause is otherfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the RRC Connection Re-establishment failures


due to other reason,and the ReestablishmentCause is otherfailures.

Explanation

For other reason, the eNodeB sends an RRCConnectionRelease message


to the UE and the ReestablishmentCause is otherfailures.Each failed RRC
connection re-establishment is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB occurs the RRC


Connection Re-establishment failures due to other reason,and the
ReestablishmentCause is otherfailures.

1-27
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.2.3.19 C373200097 Number of Inter-RAT Successful RRC Connection


Re-establishment Triggerd by Handover Failure
Definition

The counter is used to count the number of successful RRC connection


re-establishments for inter-RAT handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentComplete


message from the UE,and the ReestablishmentCause is inter-RAT
handoverfailures.
Sampling Point 3

Explanation

Receipt by the eNodeB of a RRCConnectionReestablishmentComplete


message following a RRCConnectionReestablishmentRequest in
which ReestablishmentCause is inter-RAT handoverfailures. Each
RRCConnectionReestablishmentComplete message received is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentComplete message from the UE and the
ReestablishmentCause is inter-RAT handoverfailures.

1.2.3.20 C373200098 Number of Inter-RAT Handover Failure Triggered RRC


Re-establishment Failures due to RRC Reestablish Complete Timeout
Definition

The counter is used to count the number of RRC re-establishment


failures due to timeout,and the ReestablishmentCause is inter-RAT
handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the timer of waiting for the RRCConnectionReestablishmentComplete


message expires,and the ReestablishmentCause is inter-RAT
handoverfailures.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReestablishmentComplete message not received by the eNodeB and the
ReestablishmentCause is inter-RAT handoverfailures. Each failed RRC
connection re-establishment is added to the counter.
1-28

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Updated

The counter is incremented by 1 when the eNodeB's waiting for


the RRCConnectionReestablishmentComplete timer expires,and the
ReestablishmentCause is inter-RAT handoverfailures.

1.2.3.21 C373200099 Number of Inter-RAT Handover Failure Triggered RRC


Re-establishment Failures due to ENB Admission Failure
Definition

The counter is used to count the number of RRC re-establishment failures


due to admission failure,and the ReestablishmentCause is inter-RAT
handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to admission failures, and the
ReestablishmentCause is inter-RAT handoverfailures.
Sampling Point 4

Explanation

For admission failures, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
inter-RAT handoverfailures.Each failed RRC connection re-establishment
is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due
to admission failures, and the ReestablishmentCause is inter-RAT
handoverfailures.

1.2.3.22 C373200100 Number of Inter-RAT Handover Failure Triggered RRC


Re-establishment Failures due to UE Context Not Found
Definition

The counter is used to count the number of RRC re-establishment failures


due to unknown UE identification,and the ReestablishmentCause is
inter-RAT handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

1-29
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the RRCConnectionReestablishmentReject


message to the UE due to unknown UE identification,and the
ReestablishmentCause is inter-RAT handoverfailures.
Sampling Point 4

Explanation

For not finding UE context, the eNodeB sends an RRCConnectionReestablishmentReject message to the UE and the ReestablishmentCause is
inter-RAT handoverfailures.Each failed RRC connection re-establishment
is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReestablishmentReject message to the UE due to no
finding the UE context,and the ReestablishmentCause is inter-RAT
handoverfailures.

1.2.3.23 C373200101 Number of Inter-RAT Handover Failure Triggered RRC


Re-establishment Failures due to Continue Re-establishment
Definition

The counter is used to count the number of RRC re-establishment


failures due to again receiving Reestablishment message,and the
ReestablishmentCause is inter-RAT handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to again receiving the RRCConnectionReestablishmentRequest
message,and the ReestablishmentCause is inter-RAT handoverfailures.
Sampling Point 6

Explanation

For again reestablishment, the eNodeB sends an RRCConnectionRelease


message to the UE and the ReestablishmentCause is inter-RAT
handoverfailures.Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE due to again receiving
the RRCConnectionReestablishmentRequest message,and the
ReestablishmentCause is inter-RAT handoverfailures.

1-30
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.2.3.24 C373200102 Number of Inter-RAT Handover Failure Triggered RRC


Re-establishment Failures due to Other Reason
Definition

The counter is used to count the number of RRC re-establishment


failures due to other reason,and the ReestablishmentCause is inter-RAT
handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the RRC Connection Re-establishment


failures due to other reason,and the ReestablishmentCause is inter-RAT
handoverfailures.

Explanation

For other reason, the eNodeB sends an RRCConnectionRelease


message to the UE and the ReestablishmentCause is inter-RAT
handoverfailures.Each failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB occurs the RRC


Connection Re-establishment failures due to other reason,and the
ReestablishmentCause is inter-RAT handoverfailures.

1.2.3.25 C373200103 Number of Inter-RAT RRC Connection Re-establishment Request


Triggered by Handover Failure
Definition

The counter is used to count the number of RRC re-establishment attemps,


and the ReestablishmentCause is inter-RAT handoverfailures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message, and the ReestablishmentCause is inter-RAT handoverfailures.
Sampling Point 1

Explanation

Receipt by the eNodeB of RRCConnectionReestablishmentRequest


in which ReestablishmentCause is inter-RAT handoverfailures. Each
RRCConnectionReestablishmentRequest message received is added to
the counter.

1-31
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB receives


the RRCConnectionReestablishmentRequest message, and the
ReestablishmentCause is inter-RAT handoverfailures.

1.3 RRC Connection Re-configuration


1.3.1 Flow Charts and Sampling Points
Figure 1-4 RRC Connection Re-configuration

l
l

Sampling Point 1: The eNodeb sends the RRCConnectionReconfiguration message


to UE.
Sampling Point 2: The eNodeb receives the RRCConnectionReconfigurationComplete message from UE, indicating that the RRC connection configuration has been
configed successfully.
Sampling Point 3: The eNodeb receives the RRCConnectionReestablishRequest
message from UE, After Transmission of an RRC Connection Reconfiguration
message.
Sampling
Point
4:
The
eNodeb
does
not
receive
the
RRCConnectionReconfigurationComplete message from the UE, and the timer
expires.

1-32
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373200078

Number of Successful RRC Connection Reconfig

C373200079

Number of RRC Connection Reconfig Failure due to Radio Link Failure

C373200080

Number of RRC Connection Reconfig Failure due to Other

C373200081

Number of RRC Connection Reconfig Failure due to RRC Re-establishment

C373200082

Number of Attempted RRC connection re-configurations

1.3.3 Counter Description


1.3.3.1 C373200078 Number of Successful RRC Connection Reconfig
Definition

The counter is used to count the number of successful RRC connection


reconfiguration.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE.
Sampling Point 2

Explanation

Receipt by the eNodeB of a RRCConnectionReconfigurationComplete


message following a RRC connection reconfigration during non-handover
procedure. Each RRCConnectionReconfigurationComplete message
received is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from UE during
non-Handover.

1.3.3.2 C373200079 Number of RRC Connection Reconfig Failure due to Radio Link
Failure
Definition

The counter is used to count the number of RRC reconfiguration failures


for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative
1-33

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 4

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB during non-handover
procedure. the above failed RRC connection Reconfigration is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for


the RRCConnectionReconfigurationComplete message expires during
non-Handover.

1.3.3.3 C373200080 Number of RRC Connection Reconfig Failure due to Other


Definition

The counter is used to count the number of RRC reconfiguration failures


for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the RRC connection reconfiguration failures


due to other reason.

Explanation

For other reason, an expected RRCConnectionReconfigurationComplete


message not received by the eNodeB during non-handover procedure. the
above failed RRC connection Reconfigration is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB occurs the RRC


connection reconfiguration failures due to other reason.

1.3.3.4 C373200081 Number of RRC Connection Reconfig Failure due to RRC


Re-establishment
Definition

The counter is used to count the number of RRC reconfiguration failures


for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell
1-34

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Sampling Point

When the eNodeB again receives the RRCConnectionReestablishmentRequest message from UE during waiting for the
RRCConnectionReconfigurationComplete message.
Sampling Point 3

Explanation

For again reestablishment, RRCConnectionReconfigurationComplete


message not received by the eNodeB during non-handover procedure. the
above failed RRC connection Reconfigration is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB again receives the


RRCConnectionReestablishmentRequest message from UE during
waiting for the RRCConnectionReconfigurationComplete message. This
excludes Handover.

1.3.3.5 C373200082 Number of Attempted RRC connection re-configurations


Definition

The counter is used to count the number of RRC connection reconfiguration


attempts.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


the UE during non-Handover procedure.
Sampling Point 1

Explanation

Transmission of a RRCConnectionReconfiguration message by


the eNodeB to the UE during non-Handover procedure. Each
RRCConnectionReconfiguration received is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to the UE during non-Handover
procedure.

1.4 RRC Connection Release


1.4.1 Flow Charts and Sampling Points

1-35
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 1-5 RRC Connection Release

Sampling Point 1: The EUTRAN sends the RRC CONNECTION RELEASE message
to the UE.

1.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373200020

Number of RRC Connection Release due to UserInactive Release

C373200021

Number of RRC Connection Release by MME due to UE Context Release

C373200022

Number of RRC Connection Release by ENB due to Unavailable Resource

C373200023

Number of RRC Connection Release due to Cell Block or Reset

C373200024

Number of RRC Connection Release by ENB due to Other Cause

C373200034

Number of RRC Connection Release due to UE Context Setup Timeout

C373200048

Number of RRC Connection Release by ENB due to UE Not Online

C373200049

Number of RRC Connection Release By MME due to Error Indication or


Reestablish Inter eNB

C373200050

Number of RRC Connection Release due to ENB Redirection

10

C373200051

Number of RRC Connection Release due to ENB Radio Link Failure

11

C373200052

Number of RRC Connection Release due to Re-establishment Fail

12

C373200053

Number of RRC Connection Release due to S1 Link Fail

13

C373200054

Number of RRC Connection Release By MME due to Other Reason

14

C373200083

Number of RRC Connection Releases due to Handover Failure

1.4.3 Counter Description


1.4.3.1 C373200020 Number of RRC Connection Release due to UserInactive Release
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

1-36
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE,


with release cause of UserInactive.
Sampling Point 1

Explanation

The eNodeB sends the RRCConnectionRelease message to the UE when


detecting no data in UL and DL buffer within configuration threshold. The
counter is used to count the number of this RRC Connection Release
message.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of
UserInactive.

1.4.3.2 C373200021 Number of RRC Connection Release by MME due to UE Context


Release
Definition

The counter is used to count the number of RRC Connection Release


initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand message


from the MME and the Cause in the message is "Normal Relase",
"Detach"," Authentication failure" or "Interaction with other procedure".
Sampling Point 1

Explanation

The eNodeB receives the UEContextReleaseCommand message from the


MME, in which the Cause is "Normal Release", "Detach", " Authentication
failure"or"Interaction with other procedure". The counter is used to count
the number of RRC Connection Release initiated by MME due to the
above condition.

Updated

The counter is incremented by 1 when the eNodeB receives the


UEContextReleaseCommand message from the MME and then sends
RRCConnectionRelease message to UE.

1-37
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.4.3.3 C373200022 Number of RRC Connection Release by ENB due to Unavailable


Resource
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for unavailable resource.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to detecting cell overload.
Sampling Point 1

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


appropriate UE release after detecting cell overloading. The counter is
used to count the number of RRC Connection Release initiated by eNodeB
due to the above condition.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of
overload.

1.4.3.4 C373200023 Number of RRC Connection Release due to Cell Block or Reset
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


after receiving the cell block command or reset command.
Sampling Point 1

Explanation

When the eNodeB receives the cell block command or occurs cell reset
triggerd by warning or other reason, will sends the RRCConnectionRelease
message to the UE. The counter is used to count the number of RRC
Connection Release initiated by eNodeB due to the above condition.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of cell
block or reset.

1-38
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.4.3.5 C373200024 Number of RRC Connection Release by ENB due to Other Cause
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


due to other reason.
Sampling Point 1

Explanation

The eNodeB sends the RRCConnectionRelease message to the UE when


detecting some failures for internal reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of other
reason.

1.4.3.6 C373200034 Number of RRC Connection Release due to UE Context Setup


Timeout
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for UE Context timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE, with release cause of timeout waiting for the InitialUE ContextSetup
message.
Sampling Point 1

Explanation

After the eNodeB sends initialUEMessage to MME, the


RRCConnectionRelease message is transmitted to UE by eNodeB when
the timer of waiting for the InitialContextSetupRequest message expires.
The RRCConnectionRelease message is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of timeout
of waiting for the InitialUE ContextSetup message.

1-39
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.4.3.7 C373200048 Number of RRC Connection Release by ENB due to UE Not Online
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for UE not online.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE,


with release cause of UE not online.
Sampling Point 1

Explanation

The eNodeB sends the RRCConnectionRelease message to the UE when


detecting UE not online, the counter is used to count the number of this
RRC Connection Release message.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of UE
not online.

1.4.3.8 C373200049 Number of RRC Connection Release By MME due to Error


Indication or Reestablish Inter eNB
Definition

The counter is used to count the number of RRC Connection Release


initiated by MME for Error Indication.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 1

Explanation

The counter is used to count the number of RRC Connection Release


initiated by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context. The eNodeB receives the ErrorIndication
message from the MME, then release the UE Context.

1-40
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Updated

The counter is incremented by 1 when the eNodeB receives the


ErrorIndication message or UEContextReleaseCommand message from
the MME.

1.4.3.9 C373200050 Number of RRC Connection Release due to ENB Redirection


Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE,


with release cause of redirection.
Sampling Point 1

Explanation

When the eNodeB judges the UE to access redirection condition,sends


the RRCConnectionRelease messages to the UE in which
redirectedCarrierInfo is set to on. This message is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of
redirection.

1.4.3.10 C373200051 Number of RRC Connection Release due to ENB Radio Link
Failure
Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


because of detecting radio link failures.
Sampling Point 1

1-41
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the eNodeB to UE, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE, with release cause of RLF.

1.4.3.11 C373200052 Number of RRC Connection Release due to Re-establishment Fail


Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for RRC Connection re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


due to waiting for RRCConnectionReestablishComplete message timeout.
Sampling Point 1

Explanation

When the eNodeB sends the RRCConnectionRelease message to the


UE due to waiting for RRCConnectionReestablishComplete message
timeout. Each above failed RRC connection re-establishment is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE due to waiting for
RRCConnectionReestablishComplete message timeout.

1.4.3.12 C373200053 Number of RRC Connection Release due to S1 Link Fail


Definition

The counter is used to count the number of RRC Connection Release


initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

1-42
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to detecting S1 link fault.
Sampling Point 1

Explanation

The S1 link fault refer to the following:


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE because of detecting S1
link fault.

1.4.3.13 C373200054 Number of RRC Connection Release By MME due to Other Reason
Definition

The counter is used to count the number of RRC Connection Release


initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to UE


after receiving the UEContextReleaseCommand message from MME.
Sampling Point 1

Explanation

The eNodeB receives the UEContextReleaseCommand message from


MME, in which the cause excludes Normal Release, Detach, Authentication
failure, Successful Handover,Failure in the Radio Interface Procedure and
Interaction with other procedure. The counter is used to count the number
of RRC connection Release initiated by MME due to the above condition.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to UE after receiving the
UEContextReleaseCommand message from MME.

1.4.3.14 C373200083 Number of RRC Connection Releases due to Handover Failure


Definition

The counter is used to count the number of RRC connection release


initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
1-43

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE due to handover failures.
Sampling Point 1

Explanation

Transmission of an RRCConnectionRelease message by the eNodeB


to the UE due to an expected UEContextReleaseCommand or
UEContextRelease message indicating handover complete not received
by the eNodeB. Each above RRCConnectionRelease message sent is
added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE due to handover failures

1.5 RRC Connection Number


1.5.1 Flow Charts and Sampling Points
Figure 1-6 RRC Connection Number

Sampling Point 1: When the EUTRAN receives the RRC CONNECTION SETUP
COMPLETE message from the UE, indicating that the RRC connection has been
setup successfully, the RRC connection number is incremented by 1.
1-44

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Sampling Point 2: When the EUTRAN sends the RRC CONNECTION RELEASE
message to the UE, the RRC connection number is decreased by 1.

1.5.2 Counter List


NO.

Counter

Counter Name

Number
1

C373200029

Maximum Number of RRC Connection User

C373200030

Mean Number of RRC Connection User

C373200031

Online Number of RRC Connection User

C373940406

Maximum Number of RRC Connection User (eNB)

C373940407

Mean Number of RRC Connection User (eNB)

C373940408

Online Number of RRC Connection User (eNB)

1.5.3 Counter Description


1.5.3.1 C373200029 Maximum Number of RRC Connection User
Definition

The counter is used to count the maximum number of RRC Connections in


each sampling period.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of RRC user at sampling time.


Sampling Point 1, Sampling Point 2

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the cell from other cell due to handover,the RRC
user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the cell due to handover,the RRC user number is
increased by 1.

Updated

The counter is replaced with the new value when the RRC setup user in a
sampling point is larger than the counter.

1-45
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.5.3.2 C373200030 Mean Number of RRC Connection User


Definition

The counter is used to count the mean number of RRC Connections in


each sampling period.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of RRC user at sampling time.


Sampling Point 1, Sampling Point 2

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the cell from other cell due to handover,the RRC
user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the cell due to handover,the RRC user number is
increased by 1.

Updated

The counter is updated by taking the arithmetic mean of RRC connection


setup user among sampling points.

1.5.3.3 C373200031 Online Number of RRC Connection User


Definition

The counter is used to count the online number of RRC Connections in


each sampling period.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of RRC user at sampling time.


Sampling Point 1, Sampling Point 2

1-46
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the cell from other cell due to handover,the RRC
user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the cell due to handover,the RRC user number is
increased by 1.

Updated

The counter is updated by the RRC connection setup user at last sampling
points.

1.5.3.4 C373940406 Maximum Number of RRC Connection User (eNB)


Definition

The counter is used to count the maximum number of RRC Connections


during each sampling period on eNodeB level.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

eNodeB

Sampling Point

The eNodeB collects the number of RRC user at sampling time according
to "Explanation".

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the eNodeB from other eNodeB due to
handover,the RRC user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the eNodeB due to handover,the RRC user number
is increased by 1.

Updated

The counter is replaced by the RRC Connection Establishment User in


current sampling point if it is larger than the prior in measurement period.

1.5.3.5 C373940407 Mean Number of RRC Connection User (eNB)


Definition

The counter is used to count the average number of RRC Connections


during each sampling period on eNodeB level.

Sampling Interval

10 s

1-47
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Average

Unit

Unit

Measurement Object

eNodeB

Sampling Point

The eNodeB collects the number of RRC user at sampling time according
to "Explanation".

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the eNodeB from other eNodeB due to
handover,the RRC user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the eNodeB due to handover,the RRC user number
is increased by 1.

Updated

The counter is updated by the mean number of RRC Connection


establishment User in measurement period.

1.5.3.6 C373940408 Online Number of RRC Connection User (eNB)


Definition

The counter is used to count the online number of RRC Connections


during each sampling period on eNodeB level.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

eNodeB

Sampling Point

The eNodeB collects the number of RRC user at sampling time according
to "Explanation".

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the eNodeB from other eNodeB due to
handover,the RRC user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the eNodeB due to handover,the RRC user number
is increased by 1.

Updated

The counter is replaced by the RRC Connection establishment User at the


last sampling point in measurement period.

1-48
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

1.6 RRC Connection Number(PLMN)


1.6.1 Flow Charts and Sampling Points
Figure 1-7 RRC Connection Number

Sampling Point 1: When the EUTRAN receives the RRC CONNECTION SETUP
COMPLETE message from the UE, indicating that the RRC connection has been
setup successfully, the RRC connection number is incremented by 1.
Sampling Point 2: When the EUTRAN sends the RRC CONNECTION RELEASE
message to the UE, the RRC connection number is decreased by 1.

1.6.2 Counter List


NO.

Counter

Counter Name

Number
1

C374400029

Maximum Number of RRC Connection User

C374400030

Mean Number of RRC Connection User

1-49
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

1.6.3 Counter List


1.6.3.1 C374400029 Maximum Number of RRC Connection User
Definition

The counter is used to count the maximum number of RRC Connections in


each sampling period.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of RRC user at sampling time.


Sampling Point 1, Sampling Point 2

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the cell from other cell due to handover,the RRC
user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the cell due to handover,the RRC user number is
increased by 1.

Updated

The counter is replaced with the new value when the RRC setup user in a
sampling point is larger than the counter.

1.6.3.2 C374400030 Mean Number of RRC Connection User


Definition

The counter is used to count the mean number of RRC Connections in


each sampling period.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of RRC user at sampling time.


Sampling Point 1, Sampling Point 2

1-50
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Explanation

The sampling rule of RRC Connection Establishment User is as follows:


When the eNodeB receives the RRCConnectionSetupComplete message
from the UE,the RRC user number is increased by 1.
When the UE enter into the cell from other cell due to handover,the RRC
user number is increased by 1.
When the eNodeB triggers UE release,the RRC user number is decreased
by 1.
When the UE get out the cell due to handover,the RRC user number is
increased by 1.

Updated

The counter is updated by taking the arithmetic mean of RRC connection


setup user among sampling points.

1.7 RRC Connection Time


1.7.1 Flow Charts and Sampling Points
Figure 1-8 RRC Connection Setup Time

l
l

Sampling 1:
The eNodeb records the start time when it receives the
RRCConnectionRequest message from UE.
Sampling 2:
The eNodeb records the end time when it receives the
RRCConnectionRequest message from UE.

1-51
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 1-9 RRC Connection Setup to Reconfiguration Time

l
l

Sampling Point 1: The eNodeb records the start time when it receives the
RRCConnectionRequest message from UE.
Sampling Point 2: The eNodeb records the end time when it receives the RRCConnectionReconfigurationComplete message from UE, indicating that the RRC connection
configuration has been configed successfully.

1.7.2 Counter List


NO.

Counter

Counter Name

Number
1

C373200032

Mean Time of RRC Connection Setup

C373200033

Maximum Time of RRC Connection Setup

1.7.3 Counter Description


1.7.3.1 C373200032 Mean Time of RRC Connection Setup
Definition

The counter is used to count the mean time that takes to establish an
RRC connection.

1-52
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 1 Statistics of RRC Connection

Sampling Interval

Event triggered

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionSetupRequest


message from UE, record the start time. Then receiving the
RRCConnectionSetupComplete message from UE, record the end time.
Sampling Point 1, 2.

Explanation

The time intervals for a successful RRC connection establishment


between the receipt of a RRCConnectionRequest and the corresponding
RRCConnectionSetupComplete message by the eNodeB. The counter
provides the maximum RRC connection establishment time.

Updated

The counter is updated by taking the arithmetic mean of the RRC


connection setup time among sampling points.

1.7.3.2 C373200033 Maximum Time of RRC Connection Setup


Definition

The counter is used to count the maximum time that takes to establish
an RRC connection.

Sampling Interval

Event triggered

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionSetupRequest


message from UE, record the start time. Then receiving the
RRCConnectionSetupComplete message from UE, record the end time.
Sampling Point 1, 2.

Explanation

The time intervals for a successful RRC connection establishment


between the receipt of a RRCConnectionRequest and the corresponding
RRCConnectionSetupComplete message by the eNodeB. The counter
provides the mean RRC connection establishment time.

Updated

The counter is replaced with the current value when the RRC setup time in
a sampling point is larger than the counter.

1-53
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

1-54
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2

Statistics of E-RAB
Table of Contents
Initial E-RAB Setup.....................................................................................................2-2
Additional E-RAB Setup ...........................................................................................2-45
E-RAB Modification ..................................................................................................2-87
E-RAB Release ......................................................................................................2-130
E-RAB Handover....................................................................................................2-225
E-RAB Activity........................................................................................................2-255
E-RAB Number ......................................................................................................2-265
E-RAB Setup Time .................................................................................................2-280

2-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1 Initial E-RAB Setup


2.1.1 Flow Charts and Sampling Points
Figure 2-1 Initial E-RAB Setup

l
l
l
l

Sampling Point 1: The EUTRAN receives the INITIAL CONTEXT SETUP REQUEST
message from the MME.
Sampling Point 2:
The EUTRAN sends the RRC CONNECTION
RECONFIGURATION message to the UE.
Sampling Point 3:
The EUTRAN receives the RRC CONNECTION
RECONFIGURATION COMPLETE message from the UE.
Sampling Point 4: The EUTRAN sends the INITIAL CONTEXT SETUP RESPONSE
message to the MME, indicating that the E-RAB Establishment has been set up
successfully.
Sampling
Point
5:
The
EUTRAN
does
not
receive
the
RRCConnectionReconfigurationComplete message from the UE, and the timer
2-2

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

l
l
l

expires. Then EUTRAN sends the INITIAL CONTEXT SETUP FAILURE message
to the MME.
Sampling Point 6: The EUTRAN sends the INITIAL CONTEXT SETUP FAILURE
message to the MME because of no UE context.
Sampling Point 7: The EUTRAN sends the INITIAL CONTEXT SETUP FAILURE
message to the MME because of AS failure.
Sampling Point 8:
The EUTRAN receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE.

2.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373210200

Number of Initial QCI1 SAE Bearers Successful Setup

C373210201

Number of Initial QCI1 SAE Bearers Setup Failures due to ENB Admission
Failure

C373210202

Number of Initial QCI1 SAE Bearers Setup Failures due to Uu Interface


Failure

C373210203

Number of Initial QCI1 SAE Bearers Setup Failures due to Security Failure

C373210204

Number of Initial QCI1 SAE Bearers Setup Failures due to Parameter Error

C373210205

Number of Initial QCI1 SAE Bearers Setup Failures due to Other Reason

C373210206

Number of Initial QCI2 SAE Bearers Successful Setup

C373210207

Number of Initial QCI2 SAE Bearers Setup Failures due to ENB Admission
Failure

C373210208

Number of Initial QCI2 SAE Bearers Setup Failures due to Uu Interface


Failure

10

C373210209

Number of Initial QCI2 SAE Bearers Setup Failures due to Security Failure

11

C373210210

Number of Initial QCI2 SAE Bearers Setup Failures due to Parameter Error

12

C373210211

Number of Initial QCI2 SAE Bearers Setup Failures due to Other Reason

13

C373210212

Number of Initial QCI3 SAE Bearers Successful Setup

14

C373210213

Number of Initial QCI3 SAE Bearers Setup Failures due to ENB Admission
Failure

15

C373210214

Number of Initial QCI3 SAE Bearers Setup Failures due to Uu Interface


Failure

16

C373210215

Number of Initial QCI3 SAE Bearers Setup Failures due to Security Failure

17

C373210216

Number of Initial QCI3 SAE Bearers Setup Failures due to Parameter Error

18

C373210217

Number of Initial QCI3 SAE Bearers Setup Failures due to Other Reason

19

C373210218

Number of Initial QCI4 SAE Bearers Successful Setup

2-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
20

C373210219

Number of Initial QCI4 SAE Bearers Setup Failures due to ENB Admission
Failure

21

C373210220

Number of Initial QCI4 SAE Bearers Setup Failures due to Uu Interface


Failure

22

C373210221

Number of Initial QCI4 SAE Bearers Setup Failures due to Security Failure

23

C373210222

Number of Initial QCI4 SAE Bearers Setup Failures due to Parameter Error

24

C373210223

Number of Initial QCI4 SAE Bearers Setup Failures due to Other Reason

25

C373210224

Number of Initial QCI5 SAE Bearers Successful Setup

26

C373210225

Number of Initial QCI5 SAE Bearers Setup Failures due to ENB Admission
Failure

27

C373210226

Number of Initial QCI5 SAE Bearers Setup Failures due to Uu Interface


Failure

28

C373210227

Number of Initial QCI5 SAE Bearers Setup Failures due to Security Failure

29

C373210228

Number of Initial QCI5 SAE Bearers Setup Failures due to Parameter Error

30

C373210229

Number of Initial QCI5 SAE Bearers Setup Failures due to Other Reason

31

C373210230

Number of Initial QCI6 SAE Bearers Successful Setup

32

C373210231

Number of Initial QCI6 SAE Bearers Setup Failures due to ENB Admission
Failure

33

C373210232

Number of Initial QCI6 SAE Bearers Setup Failures due to Uu Interface


Failure

34

C373210233

Number of Initial QCI6 SAE Bearers Setup Failures due to Security Failure

35

C373210234

Number of Initial QCI6 SAE Bearers Setup Failures due to Parameter Error

36

C373210235

Number of Initial QCI6 SAE Bearers Setup Failures due to Other Reason

37

C373210236

Number of Initial QCI7 SAE Bearers Successful Setup

38

C373210237

Number of Initial QCI7 SAE Bearers Setup Failures due to ENB Admission
Failure

39

C373210238

Number of Initial QCI7 SAE Bearers Setup Failures due to Uu Interface


Failure

40

C373210239

Number of Initial QCI7 SAE Bearers Setup Failures due to Security Failure

41

C373210240

Number of Initial QCI7 SAE Bearers Setup Failures due to Parameter Error

42

C373210241

Number of Initial QCI7 SAE Bearers Setup Failures due to Other Reason

43

C373210242

Number of Initial QCI8 SAE Bearers Successful Setup

44

C373210243

Number of Initial QCI8 SAE Bearers Setup Failures due to ENB Admission
Failure

2-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
45

C373210244

Number of Initial QCI8 SAE Bearers Setup Failures due to Uu Interface


Failure

46

C373210245

Number of Initial QCI8 SAE Bearers Setup Failures due to Security Failure

47

C373210246

Number of Initial QCI8 SAE Bearers Setup Failures due to Parameter Error

48

C373210247

Number of Initial QCI8 SAE Bearers Setup Failures due to Other Reason

49

C373210248

Number of Initial QCI9 SAE Bearers Successful Setup

50

C373210249

Number of Initial QCI9 SAE Bearers Setup Failures due to ENB Admission
Failure

51

C373210250

Number of Initial QCI9 SAE Bearers Setup Failures due to Uu Interface


Failure

52

C373210251

Number of Initial QCI9 SAE Bearers Setup Failures due to Security Failure

53

C373210252

Number of Initial QCI9 SAE Bearers Setup Failures due to Parameter Error

54

C373210253

Number of Initial QCI9 SAE Bearers Setup Failures due to Other Reason

55

C373505375

Number of Initial QCI1 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

56

C373505376

Number of Initial QCI2 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

57

C373505377

Number of Initial QCI3 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

58

C373505378

Number of Initial QCI4 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

59

C373505379

Number of Initial QCI5 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

60

C373505380

Number of Initial QCI6 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

61

C373505381

Number of Initial QCI7 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

62

C373505382

Number of Initial QCI8 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

63

C373505383

Number of Initial QCI9 SAE Bearers Setup Failures due to Receiving RRC
Re-establishment Request

64

C373505473

Number of Initial SAE Bearers Successful Setup

65

C373505474

Number of Initial SAE Bearers Setup Failures due to ENB Admission Failure

66

C373505475

Number of Initial SAE Bearers Setup Failures due to Uu Interface Failure

67

C373505476

Number of Initial SAE Bearers Setup Failures due to Security Failure

2-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
68

C373505477

Number of Initial SAE Bearers Setup Failures due to Parameter Error

69

C373505478

Number of Initial SAE Bearers Setup Failures due to Receiving RRC


Re-establishment Request

70

C373505479

Number of Initial SAE Bearers Setup Failures due to Other Reason

2.1.3 Counter Description


2.1.3.1 C373210200 Number of Initial QCI1 SAE Bearers Successful Setup
Definition

The counter is used to count the number of initial QCI1 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI1 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI1 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI1 E-RAB.

2.1.3.2 C373210201 Number of Initial QCI1 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI1 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB QCI1 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI1 E-RAB. But when
the eNodeB QCI1 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI1 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when


eNodeB occurs QCI1 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI1 E-RAB.

2.1.3.3 C373210202 Number of Initial QCI1 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI1 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,in which the E-RAB Setup List includes the QCI1
E-RAB. But when eNodeB replies the InitialContextSetupFailure message
to MME due to the above same.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI1 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI1 E-RAB.

2-7
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1.3.4 C373210203 Number of Initial QCI1 SAE Bearers Setup Failures due to Security
Failure
Definition

The counter is used to count the number of initial QCI1 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI1 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI1 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2.1.3.5 C373210204 Number of Initial QCI1 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI1 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI1 E-RAB.
Sampling Point 4, 6.

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI1 E-RAB failed to establish is added to the counter.

2-8
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI1
E-RAB.

2.1.3.6 C373210205 Number of Initial QCI1 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI1 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI1 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI1 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI1 E-RAB.

2.1.3.7 C373210206 Number of Initial QCI2 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI2 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI2 E-RAB.
Sampling Point 4

2-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI2 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI2 E-RAB.

2.1.3.8 C373210207 Number of Initial QCI2 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI2 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI2 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI2 E-RAB. But when
the eNodeB QCI2 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI2 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when


eNodeB occurs QCI2 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI2 E-RAB.

2.1.3.9 C373210208 Number of Initial QCI2 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI2 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-10

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI2
E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI2 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI2 E-RAB.

2.1.3.10 C373210209 Number of Initial QCI2 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI2 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI2 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI2 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1.3.11 C373210210 Number of Initial QCI2 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI2 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI2 E-RAB.
Sampling Point 4, 6.

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI2 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI2
E-RAB.

2.1.3.12 C373210211 Number of Initial QCI2 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI2 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI2 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI2 E-RAB failed to establish is added to the counter.

2-12
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI2 E-RAB.

2.1.3.13 C373210212 Number of Initial QCI3 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI3 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI3 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI3 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI3 E-RAB.

2.1.3.14 C373210213 Number of Initial QCI3 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI3 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI3 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI3 E-RAB. But when
the eNodeB QCI3 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

2-13
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI3 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when


eNodeB occurs QCI3 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI3 E-RAB.

2.1.3.15 C373210214 Number of Initial QCI3 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI3 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI3
E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI3 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI3 E-RAB.

2.1.3.16 C373210215 Number of Initial QCI3 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI3 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

2-14
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI3 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI3 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2.1.3.17 C373210216 Number of Initial QCI3 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI3 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI3 E-RAB.
Sampling Point 4, 6.

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI3 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI3
E-RAB.

2-15
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1.3.18 C373210217 Number of Initial QCI3 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI3 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI3 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI3 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI3 E-RAB.

2.1.3.19 C373210218 Number of Initial QCI4 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI4 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI4 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI4 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI4 E-RAB.

2-16
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.1.3.20 C373210219 Number of Initial QCI4 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI4 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI4 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI4 E-RAB. But when
the eNodeB QCI4 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI4 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when


eNodeB occurs QCI4 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI4 E-RAB.

2.1.3.21 C373210220 Number of Initial QCI4 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI4 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI4
E-RAB.
Sampling Point 5

2-17
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI4 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI4 E-RAB.

2.1.3.22 C373210221 Number of Initial QCI4 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI4 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI4 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI4 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2.1.3.23 C373210222 Number of Initial QCI4 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI4 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-18
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI4 E-RAB.
Sampling Point 4, 6.

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI4 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI4
E-RAB.

2.1.3.24 C373210223 Number of Initial QCI4 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI4 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI4 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI4 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI4 E-RAB.

2.1.3.25 C373210224 Number of Initial QCI5 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI5 E-RABs


successfully established.

Sampling Interval

Event triggered
2-19

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI5 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI5 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB for every QCI5
E-RAB when eNodeB sends the InitialContextSetupResponse message to
MME and the E-RAB Setup List IE includes the QCI5 E-RAB.

2.1.3.26 C373210225 Number of Initial QCI5 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI5 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI5 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI5 E-RAB. But when
the eNodeB QCI5 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI5 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when


eNodeB occurs QCI5 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI5 E-RAB.

2-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.1.3.27 C373210226 Number of Initial QCI5 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI5 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI5
E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI5 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI5 E-RAB.

2.1.3.28 C373210227 Number of Initial QCI5 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI5 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI5 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI5 E-RAB failed to establish is added to the counter.

2-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2.1.3.29 C373210228 Number of Initial QCI5 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI5 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI5 E-RAB.
Sampling Point 4, 6.

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI5 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI5
E-RAB.

2.1.3.30 C373210229 Number of Initial QCI5 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI5 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-22
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI5 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI5 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI5 E-RAB.

2.1.3.31 C373210230 Number of Initial QCI6 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI6 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI6 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI6 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI6 E-RAB.

2.1.3.32 C373210231 Number of Initial QCI6 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI6 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

2-23
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB QCI6 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI6 E-RAB. But when
the eNodeB QCI6 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI6 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when


eNodeB occurs QCI6 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI6 E-RAB.

2.1.3.33 C373210232 Number of Initial QCI6 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI6 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI6
E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI6 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI6 E-RAB.

2-24
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.1.3.34 C373210233 Number of Initial QCI6 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI6 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI6 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI6 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2.1.3.35 C373210234 Number of Initial QCI6 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI6 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI6 E-RAB.
Sampling Point 4, 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI6 E-RAB failed to establish is added to the counter.

2-25
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI6
E-RAB.

2.1.3.36 C373210235 Number of Initial QCI6 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI6 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI6 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI6 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI6 E-RAB.

2.1.3.37 C373210236 Number of Initial QCI7 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI7 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB to Setup List includes QCI7 E-RAB.
Sampling Point 4

2-26
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI7 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
to Setup List includes the QCI7 E-RAB.

2.1.3.38 C373210237 Number of Initial QCI7 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI7 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI7 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI7 E-RAB. But when
the eNodeB QCI7 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI7 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when


eNodeB occurs QCI7 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI7 E-RAB.

2.1.3.39 C373210238 Number of Initial QCI7 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI7 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-27

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI7
E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI7 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI7 E-RAB.

2.1.3.40 C373210239 Number of Initial QCI7 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI7 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI7 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI7 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2-28
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.1.3.41 C373210240 Number of Initial QCI7 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI7 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI7 E-RAB.
Sampling Point 4, 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI7 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI7
E-RAB.

2.1.3.42 C373210241 Number of Initial QCI7 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI7 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI7 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI7 E-RAB failed to establish is added to the counter.

2-29
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI7 E-RAB.

2.1.3.43 C373210242 Number of Initial QCI8 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI8 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI8 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI8 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI8 E-RAB.

2.1.3.44 C373210243 Number of Initial QCI8 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI8 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI8 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI8 E-RAB. But when
the eNodeB QCI8 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

2-30
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI8 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when


eNodeB occurs QCI8 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI8 E-RAB.

2.1.3.45 C373210244 Number of Initial QCI8 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI8 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI8
E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI8 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI8 E-RAB.

2.1.3.46 C373210245 Number of Initial QCI8 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI8 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

2-31
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI8 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI8 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends the InitialContextSetupFailure message to MME due to security
mode failures.

2.1.3.47 C373210246 Number of Initial QCI8 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI8 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI8 E-RAB.
Sampling Point 4, 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI8 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI8
E-RAB.

2-32
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.1.3.48 C373210247 Number of Initial QCI8 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI8 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI8 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI8 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI8 E-RAB.

2.1.3.49 C373210248 Number of Initial QCI9 SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial QCI9 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME,


and the E-RAB Setup List IE includes QCI9 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each QCI9 E-RAB successfully
established is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME and the E-RAB
Setup List IE includes the QCI9 E-RAB.

2-33
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1.3.50 C373210249 Number of Initial QCI9 SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial QCI9 E-RABs failed to
setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI9 E-RAB admission failures occur,eNodeB


replies the InitialContextSetupResponse message to MME, in which
the E-RAB Failed to Setup List includes the QCI9 E-RAB. But when
the eNodeB QCI9 E-RAB admission failures occur, eNodeB replies the
InitialContextSetupFailure message to MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each QCI9 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when


eNodeB occurs QCI9 E-RAB admission failures then sends the
InitialContextSetupResponse message to MME, in which the E-RAB Failed
to Setup List includes the QCI9 E-RAB.

2.1.3.51 C373210250 Number of Initial QCI9 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of initial QCI9 E-RABs failed to
setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message


to MME due to timeout of waiting for the RRCConnectionReconfigurationComplete message,and the E-RAB Setup List includes the QCI9
E-RAB.
Sampling Point 5

2-34
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP RESPONSE, or INITIAL CONTEXT SETUP FAILURE
message to the MME, in which each QCI9 E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to timeout
of waiting for the RRCConnectionReconfigurationComplete message,and
the E-RAB Setup List includes the QCI9 E-RAB.

2.1.3.52 C373210251 Number of Initial QCI9 SAE Bearers Setup Failures due to
Security Failure
Definition

The counter is used to count the number of initial QCI9 E-RABs failed to
setup for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB QCI9 E-RAB failed to setup due to security mode
failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each QCI9 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to security
mode failures,and the E-RAB Setup List includes the QCI9 E-RAB.

2.1.3.53 C373210252 Number of Initial QCI9 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of initial QCI9 E-RABs failed to
setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-35
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI9 E-RAB.
Sampling Point 4, 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
QCI9 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to message
parameter error,and the E-RAB Failed to Setup List includes the QCI9
E-RAB.

2.1.3.54 C373210253 Number of Initial QCI9 SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of initial QCI9 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse message to


MME due to other reason,and the E-RAB Failed to Setup List includes
the QCI9 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
QCI9 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends the InitialContextSetupResponse message to MME due to other
reason,and the E-RAB Failed to Setup List includes the QCI9 E-RAB.

2.1.3.55 C373505375 Number of Initial QCI1 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI1 E-RABs failed to
setup for re-establishment.

2-36
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI1 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI1 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.56 C373505376 Number of Initial QCI2 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI2 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI2 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI2 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2-37
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1.3.57 C373505377 Number of Initial QCI3 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI3 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI3 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup,the eNodeB sends an INITIAL CONTEXT SETUP
FAILURE message, each QCI3 E-RAB failed to establish is added to the
counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.58 C373505378 Number of Initial QCI4 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI4 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI4 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI4 E-RAB failed to establish is added
to the counter.

2-38
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.59 C373505379 Number of Initial QCI5 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI5 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI5 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI5 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.60 C373505380 Number of Initial QCI6 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI6 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI6 E-RAB
is included.
Sampling Point 8

2-39
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI6 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.61 C373505381 Number of Initial QCI7 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI7 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI7 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI7 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.62 C373505382 Number of Initial QCI8 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI8 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-40
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI8 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI8 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.63 C373505383 Number of Initial QCI9 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of initial QCI9 E-RABs failed to
setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment in which the QCI9 E-RAB
is included.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT
SETUP FAILURE message, each QCI9 E-RAB failed to establish is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2.1.3.64 C373505473 Number of Initial SAE Bearers Successful Setup


Definition

The counter is used to count the number of initial E-RABs successfully


established.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-41

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse to the MME.


Sampling Point 4

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE message, in which each E-RAB successfully established is
added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends the
InitialContextSetupResponse message to MME and the E-RAB Setup
List IE includes the E-RAB.

2.1.3.65 C373505474 Number of Initial SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of initial E-RABs failed to setup
for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs E-RAB admission failures then replies the
InitialContextSetupResponse or InitialContextSetupFailure message to
MME.
Sampling Point 4, Sampling Point 6

Explanation

On transmission by the eNodeB of an INITIAL CONTEXT SETUP


RESPONSE, or INITIAL CONTEXT SETUP FAILURE message for
admission failures, in which each E-RAB failed to establish is added to
the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB occurs


E-RAB admission failures then sends the InitialContextSetupResponse or
InitialContextSetupFailure message to MME.

2.1.3.66 C373505475 Number of Initial SAE Bearers Setup Failures due to Uu Interface
Failure
Definition

The counter is used to count the number of initial E-RABs failed to setup
for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

2-42
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupFailure message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an INITIAL
CONTEXT SETUP FAILURE message to the MME, in which each E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends the
InitialContextSetupFailure message to MME due to timeout of waiting for
the RRCConnectionReconfigurationComplete message.

2.1.3.67 C373505476 Number of Initial SAE Bearers Setup Failures due to Security
Failure
Definition

The counter is used to count the number of initial E-RABs failed to setup
for security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB E-RAB failed to setup due to security mode


failures,eNodeB replies the InitialContextSetupFailure message to MME.
Sampling Point 7

Explanation

When the eNodeB receives the SecurityModefailures from the UE, then
sends a INITIAL CONTEXT SETUP FAILURE message to the MME, in
which each E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


the InitialContextSetupFailure message to MME due to security mode
failures,and the E-RAB Setup List includes the E-RAB.

2-43
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.1.3.68 C373505477 Number of Initial SAE Bearers Setup Failures due to Parameter
Error
Definition

The counter is used to count the number of initial E-RABs failed to setup
for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse or


InitialContextSetupFailure message to MME due to parameter error.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for parameter error, in which each
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends the
InitialContextSetupResponse or InitialContextSetupFailure message to
MME due to parameter error.

2.1.3.69 C373505478 Number of Initial SAE Bearers Setup Failures due to Receiving
RRC Re-establishment Request
Definition

The counter is used to count the number of initial E-RABs failed to setup
for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialContextSetupfailure message to the


MME due to eNodeB RRC re-establishment.
Sampling Point 8

Explanation

For receiving the RRCConnection ReestablishmentRequest message


during UE Context setup, the eNodeB sends an INITIAL CONTEXT SETUP
FAILURE message, each E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the InitialContextSetupfailure message to the MME due to RRC
re-establishment.

2-44
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.1.3.70 C373505479 Number of Initial SAE Bearers Setup Failures due to Other Reason
Definition

The counter is used to count the number of initial E-RABs failed to setup
for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the InitialContextSetupResponse or


InitialContextSetupFailure message to MME due to other reason.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the InitialContextSetupRequest from the


MME, then replies an INITIAL CONTEXT SETUP RESPONSE, or INITIAL
CONTEXT SETUP FAILURE message for other reason, in which each
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends the
InitialContextSetupResponse or InitialContextSetupFailure message to
MME due to other reason.

2.2 Additional E-RAB Setup


2.2.1 Flow Charts and Sampling Points

2-45
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 2-2 Additional E-RAB Setup

l
l
l
l
l

Sampling Point 1: The EUTRAN receives the E-RAB SETUP REQUEST message
from the MME.
Sampling Point 2: The EUTRAN sends the RRC CONNECTION RECONFIGURATION message to the UE.
Sampling Point 3:
The EUTRAN receives the RRC CONNECTION
RECONFIGURATION COMPLETE message from the UE.
Sampling Point 4: The EUTRAN sends the E-RAB SETUP RESPONSE message to
the MME, indicating that the E-RAB Establishment has been set up successfully.
Sampling
Point
5:
The
EUTRAN
does
not
receive
the
RRCConnectionReconfigurationComplete message from the UE, and the timer
expires. Then EUTRAN sends the E-RAB SETUP FAILURE message to the MME.

2.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373210254

Number of Additional QCI1 SAE Bearers Successful Setup

C373210255

Number of Additional QCI1 SAE Bearers Setup Failures due to ENB


Admission Failure

C373210256

Number of Additional QCI1 SAE Bearers Setup Failures due to Uu Interface


Failure

C373210257

Number of Additional QCI1 SAE Bearers Setup Failures due to Handover


Trigger

2-46
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
5

C373210258

Number of Additional QCI1 SAE Bearers Setup Failures due to Parameter


Error

C373210259

Number of Additional QCI1 SAE Bearers Setup Failures due to Other Reason

C373210260

Number of Additional QCI2 SAE Bearers Successful Setup

C373210261

Number of Additional QCI2 SAE Bearers Setup Failures due to ENB


Admission Failure

C373210262

Number of Additional QCI2 SAE Bearers Setup Failures due to Uu Interface


Failure

10

C373210263

Number of Additional QCI2 SAE Bearers Setup Failures due to Handover


Trigger

11

C373210264

Number of Additional QCI2 SAE Bearers Setup Failures due to Parameter


Error

12

C373210265

Number of Additional QCI2 SAE Bearers Setup Failures due to Other Reason

13

C373210266

Number of Additional QCI3 SAE Bearers Successful Setup

14

C373210267

Number of Additional QCI3 SAE Bearers Setup Failures due to ENB


Admission Failure

15

C373210268

Number of Additional QCI3 SAE Bearers Setup Failures due to Uu Interface


Failure

16

C373210269

Number of Additional QCI3 SAE Bearers Setup Failures due to Handover


Trigger

17

C373210270

Number of Additional QCI3 SAE Bearers Setup Failures due to Parameter


Error

18

C373210271

Number of Additional QCI3 SAE Bearers Setup Failures due to Other Reason

19

C373210272

Number of Additional QCI4 SAE Bearers Successful Setup

20

C373210273

Number of Additional QCI4 SAE Bearers Setup Failures due to ENB


Admission Failure

21

C373210274

Number of Additional QCI4 SAE Bearers Setup Failures due to Uu Interface


Failure

22

C373210275

Number of Additional QCI4 SAE Bearers Setup Failures due to Handover


Trigger

23

C373210276

Number of Additional QCI4 SAE Bearers Setup Failures due to Parameter


Error

24

C373210277

Number of Additional QCI4 SAE Bearers Setup Failures due to Other Reason

25

C373210278

Number of Additional QCI5 SAE Bearers Successful Setup

2-47
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
26

C373210279

Number of Additional QCI5 SAE Bearers Setup Failures due to ENB


Admission Failure

27

C373210280

Number of Additional QCI5 SAE Bearers Setup Failures due to Uu Interface


Failure

28

C373210281

Number of Additional QCI5 SAE Bearers Setup Failures due to Handover


Trigger

29

C373210282

Number of Additional QCI5 SAE Bearers Setup Failures due to Parameter


Error

30

C373210283

Number of Additional QCI5 SAE Bearers Setup Failures due to Other Reason

31

C373210284

Number of Additional QCI6 SAE Bearers Successful Setup

32

C373210285

Number of Additional QCI6 SAE Bearers Setup Failures due to ENB


Admission Failure

33

C373210286

Number of Additional QCI6 SAE Bearers Setup Failures due to Uu Interface


Failure

34

C373210287

Number of Additional QCI6 SAE Bearers Setup Failures due to Handover


Trigger

35

C373210288

Number of Additional QCI6 SAE Bearers Setup Failures due to Parameter


Error

36

C373210289

Number of Additional QCI6 SAE Bearers Setup Failures due to Other Reason

37

C373210290

Number of Additional QCI7 SAE Bearers Successful Setup

38

C373210291

Number of Additional QCI7 SAE Bearers Setup Failures due to ENB


Admission Failure

39

C373210292

Number of Additional QCI7 SAE Bearers Setup Failures due to Uu Interface


Failure

40

C373210293

Number of Additional QCI7 SAE Bearers Setup Failures due to Handover


Trigger

41

C373210294

Number of Additional QCI7 SAE Bearers Setup Failures due to Parameter


Error

42

C373210295

Number of Additional QCI7 SAE Bearers Setup Failures due to Other Reason

43

C373210296

Number of Additional QCI8 SAE Bearers Successful Setup

44

C373210297

Number of Additional QCI8 SAE Bearers Setup Failures due to ENB


Admission Failure

45

C373210298

Number of Additional QCI8 SAE Bearers Setup Failures due to Uu Interface


Failure

2-48
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
46

C373210299

Number of Additional QCI8 SAE Bearers Setup Failures due to Handover


Trigger

47

C373210300

Number of Additional QCI8 SAE Bearers Setup Failures due to Parameter


Error

48

C373210301

Number of Additional QCI8 SAE Bearers Setup Failures due to Other Reason

49

C373210302

Number of Additional QCI9 SAE Bearers Successful Setup

50

C373210303

Number of Additional QCI9 SAE Bearers Setup Failures due to ENB


Admission Failure

51

C373210304

Number of Additional QCI9 SAE Bearers Setup Failures due to Uu Interface


Failure

52

C373210305

Number of Additional QCI9 SAE Bearers Setup Failures due to Handover


Trigger

53

C373210306

Number of Additional QCI9 SAE Bearers Setup Failures due to Parameter


Error

54

C373210307

Number of Additional QCI9 SAE Bearers Setup Failures due to Other Reason

55

C373505384

Number of Additional QCI1 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

56

C373505385

Number of Additional QCI2 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

57

C373505386

Number of Additional QCI3 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

58

C373505387

Number of Additional QCI4 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

59

C373505388

Number of Additional QCI5 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

60

C373505389

Number of Additional QCI6 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

61

C373505390

Number of Additional QCI7 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

62

C373505391

Number of Additional QCI8 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

63

C373505392

Number of Additional QCI9 SAE Bearers Setup Failures due to Receiving


RRC Re-establishment Request

64

C373505481

Number of Additional SAE Bearers Successful Setup

65

C373505482

Number of Additional SAE Bearers Setup Failures due to ENB Admission


Failure
2-49

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
66

C373505483

Number of Additional SAE Bearers Setup Failures due to Uu Interface Failure

67

C373505484

Number of Additional SAE Bearers Setup Failures due to Handover Trigger

68

C373505485

Number of Additional SAE Bearers Setup Failures due to Parameter Error

69

C373505486

Number of Additional SAE Bearers Setup Failures due to Receiving RRC


Re-establishment Request

70

C373505487

Number of Additional SAE Bearers Setup Failures due to Other Reason

2.2.3 Counter Description


2.2.3.1 C373210254 Number of Additional QCI1 SAE Bearers Successful Setup
Definition

The counter is used to count the number of additional QCI1 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI1 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI1 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI1 E-RAB.

2.2.3.2 C373210255 Number of Additional QCI1 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI1 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-50

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI1 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI1 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI1 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


occurs QCI1 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI1 E-RAB.

2.2.3.3 C373210256 Number of Additional QCI1 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of additional QCI1 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI1 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI1 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI1 E-RAB.

2.2.3.4 C373210257 Number of Additional QCI1 SAE Bearers Setup Failures due to
Handover Trigger
Definition

The counter is used to count the number of additional QCI1 E-RABs failed
to setup for handover trigger.
2-51

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
QCI1 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI1 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger, and the
E-RAB Failed to Setup List includes the QCI1 E-RAB.

2.2.3.5 C373210258 Number of Additional QCI1 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI1 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI1 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI1 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI1 E-RAB.

2-52
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.2.3.6 C373210259 Number of Additional QCI1 SAE Bearers Setup Failures due to
Other Reason
Definition

The counter is used to count the number of additional QCI1 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI1
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI1 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI1 E-RAB.

2.2.3.7 C373210260 Number of Additional QCI2 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI2 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI2 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI2 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI2 E-RAB.

2-53
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.2.3.8 C373210261 Number of Additional QCI2 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI2 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI2 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI2 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI2 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


occurs QCI2 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI2 E-RAB.

2.2.3.9 C373210262 Number of Additional QCI2 SAE Bearers Setup Failures due to Uu
Interface Failure
Definition

The counter is used to count the number of additional QCI2 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI2 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI2 E-RAB
failed to establish is added to the counter.

2-54
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI2 E-RAB.

2.2.3.10 C373210263 Number of Additional QCI2 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI2 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger, and the E-RAB Failed to Setup List includes the
QCI2 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI2 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger, and the
E-RAB Failed to Setup List includes the QCI2 E-RAB.

2.2.3.11 C373210264 Number of Additional QCI2 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI2 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI2 E-RAB.
Sampling Point 4, Sampling Point 6

2-55
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB receives the E-RABContextSetupRequest from the


MME, then replies an E-RAB SETUP RESPONSE message for parameter
error, in which each QCI2 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI2 E-RAB.

2.2.3.12 C373210265 Number of Additional QCI2 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI2 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI2
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI2 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI2 E-RAB.

2.2.3.13 C373210266 Number of Additional QCI3 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI3 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI3 E-RAB.
Sampling Point 4.
2-56

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI3 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI3 E-RAB.

2.2.3.14 C373210267 Number of Additional QCI3 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI3 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI3 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI3 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI3 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


occurs QCI3 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI3 E-RAB.

2.2.3.15 C373210268 Number of Additional QCI3 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI3 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-57
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI3 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI3 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI3 E-RAB.

2.2.3.16 C373210269 Number of Additional QCI3 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI3 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger, and the E-RAB Failed to Setup List includes the
QCI3 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI3 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger, and the
E-RAB Failed to Setup List includes the QCI3 E-RAB.

2.2.3.17 C373210270 Number of Additional QCI3 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI3 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-58

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI3 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI3 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI3 E-RAB.

2.2.3.18 C373210271 Number of Additional QCI3 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI3 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI3
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI3 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI3 E-RAB.

2.2.3.19 C373210272 Number of Additional QCI4 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI4 E-RABs


successfully established.

Sampling Interval

Event triggered

2-59
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI4 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI4 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI4 E-RAB.

2.2.3.20 C373210273 Number of Additional QCI4 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI4 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI4 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI4 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI4 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


occurs QCI4 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI4 E-RAB.

2.2.3.21 C373210274 Number of Additional QCI4 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI4 E-RABs failed
to setup for RRC reconfiguration complete timeout.

2-60
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI4 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI4 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI4 E-RAB.

2.2.3.22 C373210275 Number of Additional QCI4 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI4 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger, and the E-RAB Failed to Setup List includes the
QCI4 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI4 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger, and the
E-RAB Failed to Setup List includes the QCI4 E-RAB.

2-61
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.2.3.23 C373210276 Number of Additional QCI4 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI4 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI4 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI4 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI4 E-RAB.

2.2.3.24 C373210277 Number of Additional QCI4 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI4 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI4
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI4 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI4 E-RAB.

2-62
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.2.3.25 C373210278 Number of Additional QCI5 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI5 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI5 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI5 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI5 E-RAB.

2.2.3.26 C373210279 Number of Additional QCI5 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI5 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI5 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI5 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI5 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


occurs QCI5 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI5 E-RAB.

2-63
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.2.3.27 C373210280 Number of Additional QCI5 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI5 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI5 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI5 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI5 E-RAB.

2.2.3.28 C373210281 Number of Additional QCI5 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI5 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
QCI5 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI5 E-RAB failed to establish is added to the counter.

2-64
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger,and the
E-RAB Failed to Setup List includes the QCI5 E-RAB.

2.2.3.29 C373210282 Number of Additional QCI5 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI5 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI5 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI5 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI5 E-RAB.

2.2.3.30 C373210283 Number of Additional QCI5 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI5 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI5
E-RAB.
Sampling Point 4, Sampling Point 6

2-65
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI5 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI5 E-RAB.

2.2.3.31 C373210284 Number of Additional QCI6 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI6 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI6 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI6 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI6 E-RAB.

2.2.3.32 C373210285 Number of Additional QCI6 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI6 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI6 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI6 E-RAB.
Sampling Point 4, 6
2-66

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI6 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


occurs QCI6 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI6 E-RAB.

2.2.3.33 C373210286 Number of Additional QCI6 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI6 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI6 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI6 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI6 E-RAB.

2.2.3.34 C373210287 Number of Additional QCI6 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI6 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-67
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
QCI6 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI6 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger,and the
E-RAB Failed to Setup List includes the QCI6 E-RAB.

2.2.3.35 C373210288 Number of Additional QCI6 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI6 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI6 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI6 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI6 E-RAB.

2.2.3.36 C373210289 Number of Additional QCI6 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI6 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

2-68
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI6
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI6 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI6 E-RAB.

2.2.3.37 C373210290 Number of Additional QCI7 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI7 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB to Setup List includes QCI7 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI7 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB to Setup List
includes the QCI7 E-RAB.

2.2.3.38 C373210291 Number of Additional QCI7 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI7 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-69

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI7 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI7 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI7 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


occurs QCI7 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI7 E-RAB.

2.2.3.39 C373210292 Number of Additional QCI7 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI7 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI7 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI7 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI7 E-RAB.

2.2.3.40 C373210293 Number of Additional QCI7 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI7 E-RABs failed
to setup for handover trigger.
2-70

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
QCI7 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI7 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger,and the
E-RAB Failed to Setup List includes the QCI7 E-RAB.

2.2.3.41 C373210294 Number of Additional QCI7 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI7 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI7 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI7 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI7 E-RAB.

2-71
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.2.3.42 C373210295 Number of Additional QCI7 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI7 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI7
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI7 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI7 E-RAB.

2.2.3.43 C373210296 Number of Additional QCI8 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI8 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI8 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI8 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI8 E-RAB.

2-72
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.2.3.44 C373210297 Number of Additional QCI8 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI8 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI8 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI8 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI8 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


occurs QCI8 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI8 E-RAB.

2.2.3.45 C373210298 Number of Additional QCI8 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI8 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI8 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI8 E-RAB
failed to establish is added to the counter.

2-73
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI8 E-RAB.

2.2.3.46 C373210299 Number of Additional QCI8 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI8 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
QCI8 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI8 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger,and the
E-RAB Failed to Setup List includes the QCI8 E-RAB.

2.2.3.47 C373210300 Number of Additional QCI8 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI8 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI8 E-RAB.
Sampling Point 4, Sampling Point 6

2-74
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI8 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI8 E-RAB.

2.2.3.48 C373210301 Number of Additional QCI8 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI8 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI8
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI8 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI8 E-RAB.

2.2.3.49 C373210302 Number of Additional QCI9 SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional QCI9 E-RABs


successfully established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes QCI9 E-RAB.
Sampling Point 4.
2-75

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each QCI9 E-RAB successfully established is added to
the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABSetupResponse to MME and the E-RAB Setup List IE
includes the QCI9 E-RAB.

2.2.3.50 C373210303 Number of Additional QCI9 SAE Bearers Setup Failures due to
ENB Admission Failure
Definition

The counter is used to count the number of additional QCI9 E-RABs failed
to setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI9 E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the QCI9 E-RAB.
Sampling Point 4, 6

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each QCI9 E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


occurs QCI9 E-RAB admission failures then sends E-RABSetupResponse
to MME, in which the E-RAB Failed to Setup List includes the QCI9 E-RAB.

2.2.3.51 C373210304 Number of Additional QCI9 SAE Bearers Setup Failures due
to Uu Interface Failure
Definition

The counter is used to count the number of additional QCI9 E-RABs failed
to setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-76
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the QCI9 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each QCI9 E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the QCI9 E-RAB.

2.2.3.52 C373210305 Number of Additional QCI9 SAE Bearers Setup Failures due
to Handover Trigger
Definition

The counter is used to count the number of additional QCI9 E-RABs failed
to setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
QCI9 E-RAB.
Sampling Point 6

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each QCI9 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to handover trigger,and the
E-RAB Failed to Setup List includes the QCI9 E-RAB.

2.2.3.53 C373210306 Number of Additional QCI9 SAE Bearers Setup Failures due to
Parameter Error
Definition

The counter is used to count the number of additional QCI9 E-RABs failed
to setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-77

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to message parameter error, and the E-RAB Failed to Setup List
includes the QCI9 E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each QCI9 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to message parameter
error,and the E-RAB Failed to Setup List includes the QCI9 E-RAB.

2.2.3.54 C373210307 Number of Additional QCI9 SAE Bearers Setup Failures due
to Other Reason
Definition

The counter is used to count the number of additional QCI9 E-RABs failed
to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to other reason,and the E-RAB Failed to Setup List includes the QCI9
E-RAB.
Sampling Point 4, Sampling Point 6

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each QCI9 E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABSetupResponse to MME due to other reason,and the E-RAB
Failed to Setup List includes the QCI9 E-RAB.

2.2.3.55 C373505384 Number of Additional QCI1 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI1 E-RABs failed
to setup for re-establishment.

2-78
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI1 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI1
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI1
E-RAB.

2.2.3.56 C373505385 Number of Additional QCI2 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI2 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI2 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI2
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E- RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI2
E-RAB.

2-79
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.2.3.57 C373505386 Number of Additional QCI3 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI3 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI3 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI3
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI3
E-RAB.

2.2.3.58 C373505387 Number of Additional QCI4 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI4 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI4 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI4
E-RAB failed to establish is added to the counter.

2-80
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI4
E-RAB.

2.2.3.59 C373505388 Number of Additional QCI5 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI5 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI5 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI5
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI5
E-RAB.

2.2.3.60 C373505389 Number of Additional QCI6 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI6 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-81
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI6 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI6
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI6
E-RAB.

2.2.3.61 C373505390 Number of Additional QCI7 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI7 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI7 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI7
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI7
E-RAB.

2.2.3.62 C373505391 Number of Additional QCI8 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI8 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered
2-82

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI8 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI8
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI8
E-RAB.

2.2.3.63 C373505392 Number of Additional QCI9 SAE Bearers Setup Failures due to
Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional QCI9 E-RABs failed
to setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes QCI9 E-RAB.
Sampling Point 6

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each QCI9
E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes QCI9
E-RAB.

2-83
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.2.3.64 C373505481 Number of Additional SAE Bearers Successful Setup


Definition

The counter is used to count the number of additional E-RABs successfully


established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse to the MME, and the
E-RAB Setup List IE includes E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message, in which each E-RAB successfully established is added to the
counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABSetupResponse to MME and the E-RAB Setup List IE includes
the E-RAB.

2.2.3.65 C373505482 Number of Additional SAE Bearers Setup Failures due to ENB
Admission Failure
Definition

The counter is used to count the number of additional E-RABs failed to


setup for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs E-RAB admission failures then replies the
E-RABSetupResponse message to MME, in which the E-RAB Failed to
Setup List includes the E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB SETUP RESPONSE


message for admission failures, in which each E-RAB failed to establish is
added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB occurs


E-RAB admission failures then sends E-RABSetupResponse to MME, in
which the E-RAB Failed to Setup List includes the E-RAB.

2-84
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.2.3.66 C373505483 Number of Additional SAE Bearers Setup Failures due to Uu


Interface Failure
Definition

The counter is used to count the number of additional E-RABs failed to


setup for RRC reconfiguration complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB Failed to Setup List includes the E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
SETUP RESPONSE message to the MME, in which each E-RAB failed to
establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB


sends E-RABSetupResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Setup List includes the E-RAB.

2.2.3.67 C373505484 Number of Additional SAE Bearers Setup Failures due to


Handover Trigger
Definition

The counter is used to count the number of additional E-RABs failed to


setup for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABSetupResponse message to MME


due to handover trigger,and the E-RAB Failed to Setup List includes the
E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB SETUP RESPONSE message to the


MME, in which each E-RAB failed to establish is added to the counter.

2-85
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABSetupResponse to MME due to handover trigger, and the E-RAB
Failed to Setup List includes the E-RAB.

2.2.3.68 C373505485 Number of Additional SAE Bearers Setup Failures due to


Parameter Error
Definition

The counter is used to count the number of additional E-RABs failed to


setup for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each E-RAB failed to establish is added to the counter.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for parameter error, in
which each E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABSetupResponse to MME due to message parameter error,and the
E-RAB Failed to Setup List includes the E-RAB.

2.2.3.69 C373505486 Number of Additional SAE Bearers Setup Failures due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of additional E-RABs failed to


setup for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABSetupResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Setup
List includes E-RAB.
Sampling Point 4

2-86
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends an E-RAB SETUP RESPONSE message, each E-RAB
failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the eNodeB
sends the E-RABSetupResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Setup List includes E-RAB.

2.2.3.70 C373505487 Number of Additional SAE Bearers Setup Failures due to Other
Reason
Definition

The counter is used to count the number of additional E-RABs failed


to setup for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each E-RAB failed to establish is added to the counter.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABSetupRequest from the MME, then
replies an E-RAB SETUP RESPONSE message for other reason, in which
each E-RAB failed to establish is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABSetupResponse to MME due to other reason,and the E-RAB Failed
to Setup List includes the E-RAB.

2.3 E-RAB Modification


2.3.1 Flow Charts and Sampling Points

2-87
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 2-3 E-RAB Modification

l
l
l
l
l

Sampling Point 1: The EUTRAN receives the E-RAB MODIFY REQUEST message
from the MME.
Sampling Point 2: The EUTRAN sends the RRC CONNECTION RECONFIGURATION message to the UE.
Sampling Point 3:
The EUTRAN receives the RRC CONNECTION
RECONFIGURATION COMPLETE message from the UE.
Sampling Point 4: The EUTRAN sends the E-RAB MODIFY RESPONSE message to
the MME, indicating that the E-RAB Modification has been successful or failed.
Sampling Point 5:
The EUTRAN waits for the RRC CONNECTION
RECONFIGURATION COMPLETE message from the UE until the timer is timeout,
then the EUTRAN sends the E-RAB MODIFY RESPONSE message to the
MME,indicating that the E-RAB Modification has failed.

2.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373210308

Number of QCI1 SAE Bearers Successful Modification

C373210309

Number of QCI1 SAE Bearers Modification Failure due to ENB Admission


Failure

C373210310

Number of QCI1 SAE Bearers Modification Failure due to Uu Interface


Failure

C373210311

Number of QCI1 SAE Bearers Modification Failure due to Handover Trigger

C373210312

Number of QCI1 SAE Bearers Modification Failure due to Parameter Error

C373210313

Number of QCI1 SAE Bearers Modification Failure due to Other Reason

2-88
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
7

C373210314

Number of QCI2 SAE Bearers Successful Modification

C373210315

Number of QCI2 SAE Bearers Modification Failure due to ENB Admission


Failure

C373210316

Number of QCI2 SAE Bearers Modification Failure due to Uu Interface


Failure

10

C373210317

Number of QCI2 SAE Bearers Modification Failure due to Handover Trigger

11

C373210318

Number of QCI2 SAE Bearers Modification Failure due to Parameter Error

12

C373210319

Number of QCI2 SAE Bearers Modification Failure due to Other Reason

13

C373210320

Number of QCI3 SAE Bearers Successful Modification

14

C373210321

Number of QCI3 SAE Bearers Modification Failure due to ENB Admission

15

C373210322

Number of QCI3 SAE Bearers Modification Failure due to Uu Interface


Failure

16

C373210323

Number of QCI3 SAE Bearers Modification Failure due to Handover Trigger

17

C373210324

Number of QCI3 SAE Bearers Modification Failure due to Parameter Error

18

C373210325

Number of QCI3 SAE Bearers Modification Failure due to Other Reason

19

C373210326

Number of QCI4 SAE Bearers Successful Modification

20

C373210327

Number of QCI4 SAE Bearers Modification Failure due to ENB Admission


Failure

21

C373210328

Number of QCI4 SAE Bearers Modification Failure due to Uu Interface


Failure

22

C373210329

Number of QCI4 SAE Bearers Modification Failure due to Handover Trigger

23

C373210330

Number of QCI4 SAE Bearers Modification Failure due to Parameter Error

24

C373210331

Number of QCI4 SAE Bearers Modification Failure due to Other Reason

25

C373210332

Number of QCI5 SAE Bearers Successful Modification

26

C373210333

Number of QCI5 SAE Bearers Modification Failure due to ENB Admission


Failure

27

C373210334

Number of QCI5 SAE Bearers Modification Failure due to Uu Interface


Failure

28

C373210335

Number of QCI5 SAE Bearers Modification Failure due to Handover Trigger

29

C373210336

Number of QCI5 SAE Bearers Modification Failure due to Parameter Error

30

C373210337

Number of QCI5 SAE Bearers Modification Failure due to Other Reason

31

C373210338

Number of QCI6 SAE Bearers Successful Modification

32

C373210339

Number of QCI6 SAE Bearers Modification Failure due to ENB Admission


Failure

2-89
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
33

C373210340

Number of QCI6 SAE Bearers Modification Failure due to Uu Interface


Failure

34

C373210341

Number of QCI6 SAE Bearers Modification Failure due to Handover Trigger

35

C373210342

Number of QCI6 SAE Bearers Modification Failure due to Parameter Error

36

C373210343

Number of QCI6 SAE Bearers Modification Failure due to Other Reason

37

C373210344

Number of QCI7 SAE Bearers Successful Modification

38

C373210345

Number of QCI7 SAE Bearers Modification Failure due to ENB Admission


Failure

39

C373210346

Number of QCI7 SAE Bearers Modification Failure due to Uu Interface


Failure

40

C373210347

Number of QCI7 SAE Bearers Modification Failure due to Handover Trigger

41

C373210348

Number of QCI7 SAE Bearers Modification Failure due to Parameter Error

42

C373210349

Number of QCI7 SAE Bearers Modification Failure due to Other Reason

43

C373210350

Number of QCI8 SAE Bearers Successful Modification

44

C373210351

Number of QCI8 SAE Bearers Modification Failure due to ENB Admission


Failure

45

C373210352

Number of QCI8 SAE Bearers Modification Failure due to Uu Interface


Failure

46

C373210353

Number of QCI8 SAE Bearers Modification Failure due to Handover Trigger

47

C373210354

Number of QCI8 SAE Bearers Modification Failure due to Parameter Error

48

C373210355

Number of QCI8 SAE Bearers Modification Failure due to Other Reason

49

C373210356

Number of QCI9 SAE Bearers Successful Modification

50

C373210357

Number of QCI9 SAE Bearers Modification Failure due to ENB Admission


Failure

51

C373210358

Number of QCI9 SAE Bearers Modification Failure due to Uu Interface


Failure

52

C373210359

Number of QCI9 SAE Bearers Modification Failure due to Handover Trigger

53

C373210360

Number of QCI9 SAE Bearers Modification Failure due to Parameter Error

54

C373210361

Number of QCI9 SAE Bearers Modification Failure due to Other Reason

55

C373505393

Number of QCI1 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

56

C373505394

Number of QCI2 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

2-90
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
57

C373505395

Number of QCI3 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

58

C373505396

Number of QCI4 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

59

C373505397

Number of QCI5 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

60

C373505398

Number of QCI6 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

61

C373505399

Number of QCI7 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

62

C373505400

Number of QCI8 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

63

C373505401

Number of QCI9 SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

64

C373505489

Number of SAE Bearers Successful Modification

65

C373505490

NNumber of SAE Bearers Modification Failure due to ENB Admission Failure

66

C373505491

Number of SAE Bearers Modification Failure due to Uu Interface Failure

67

C373505492

Number of SAE Bearers Modification Failure due to Handover Trigger

68

C373505493

Number of SAE Bearers Modification Failure due to Parameter Error

69

C373505494

Number of SAE Bearers Modification Failure due to Receiving RRC


Re-establishment Request

70

C373505495

Number of SAE Bearers Modification Failure due to Other Reason

2.3.3 Counter Description


2.3.3.1 C373210308 Number of QCI1 SAE Bearers Successful Modification
Definition

The counter is used to count the number of QCI1 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-91
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI1 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI1 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI1 E-RAB.

2.3.3.2 C373210309 Number of QCI1 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI1 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI1 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI1 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI1 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


occurs QCI1 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI1
E-RAB.

2.3.3.3 C373210310 Number of QCI1 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI1 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

2-92
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI1 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI1 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI1 E-RAB.

2.3.3.4 C373210311 Number of QCI1 SAE Bearers Modification Failure due to Handover
Trigger
Definition

The counter is used to count the number of QCI1 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI1 E-RAB.
Sampling Point 4.

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI1 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI1 E-RAB.

2-93
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.3.3.5 C373210312 Number of QCI1 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI1 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error,and the E-RAB failed to Modify List
includes the QCI1 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI1 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter
error,and the E-RAB Failed to Modify List includes the QCI1 E-RAB.

2.3.3.6 C373210313 Number of QCI1 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI1 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI1
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI1 E-RAB failed to modify the QoS parameter is
added to the counter.

2-94
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI1 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI1 E-RAB.

2.3.3.7 C373210314 Number of QCI2 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI2 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI2 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI2 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI2 E-RAB.

2.3.3.8 C373210315 Number of QCI2 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI2 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI2 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI2 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI2 E-RAB failed to
modify the QoS parameter is added to the counter.
2-95

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


occurs QCI2 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI2
E-RAB.

2.3.3.9 C373210316 Number of QCI2 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI2 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI2 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI2 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI2 E-RAB.

2.3.3.10 C373210317 Number of QCI2 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI2 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-96
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI2 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI2 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI2 E-RAB.

2.3.3.11 C373210318 Number of QCI2 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI2 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI2 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI2 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter
error,and the E-RAB Failed to Modify List includes the QCI2 E-RAB.

2.3.3.12 C373210319 Number of QCI2 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI2 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-97

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI2
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI2 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI2 E-RAB.

2.3.3.13 C373210320 Number of QCI3 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI3 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI3 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI3 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI3 E-RAB.

2.3.3.14 C373210321 Number of QCI3 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI3 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-98

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI3 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI3 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI3 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


occurs QCI3 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI3
E-RAB.

2.3.3.15 C373210322 Number of QCI3 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI3 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI3 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI3 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI3 E-RAB.

2-99
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.3.3.16 C373210323 Number of QCI3 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI3 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI3 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI3 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI3 E-RAB.

2.3.3.17 C373210324 Number of QCI3 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI3 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI3 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI3 E-RAB failed to modify the QoS
parameter is added to the counter.

2-100
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter error,
and the E-RAB Failed to Modify List includes the QCI3 E-RAB.

2.3.3.18 C373210325 Number of QCI3 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI3 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI3
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI3 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason, and the
E-RAB Failed to Modify List includes the QCI3 E-RAB.

2.3.3.19 C373210326 Number of QCI4 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI4 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI4 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI4 E-RAB successfully modified the QoS
parameter is added to the counter.
2-101

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI4 E-RAB.

2.3.3.20 C373210327 Number of QCI4 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI4 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI4 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI4 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI4 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


occurs QCI4 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI4
E-RAB.

2.3.3.21 C373210328 Number of QCI4 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI4 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI4 E-RAB.
Sampling Point 5

2-102
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI4 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI4 E-RAB.

2.3.3.22 C373210329 Number of QCI4 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI4 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI4 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI4 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI4 E-RAB.

2.3.3.23 C373210330 Number of QCI4 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI4 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-103
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI4 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI4 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter error,
and the E-RAB Failed to Modify List includes the QCI4 E-RAB.

2.3.3.24 C373210331 Number of QCI4 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI4 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI4
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI4 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI4 E-RAB.

2.3.3.25 C373210332 Number of QCI5 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI5 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-104

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to the


MME, and the E-RAB Modify List IE includes QCI5 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI5 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends the E-RABModifyResponse message to MME and the E-RAB
Modify List IE includes the QCI5 E-RAB.

2.3.3.26 C373210333 Number of QCI5 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI5 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI5 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI5 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI5 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


occurs QCI5 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI5
E-RAB.

2.3.3.27 C373210334 Number of QCI5 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI5 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

2-105
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI5 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI5 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI5 E-RAB.

2.3.3.28 C373210335 Number of QCI5 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI5 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI5 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI5 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI5 E-RAB.

2-106
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.3.3.29 C373210336 Number of QCI5 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI5 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI5 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI5 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter
error,and the E-RAB Failed to Modify List includes the QCI5 E-RAB.

2.3.3.30 C373210337 Number of QCI5 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI5 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI5
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI5 E-RAB failed to modify the QoS parameter is
added to the counter.

2-107
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI5 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI5 E-RAB.

2.3.3.31 C373210338 Number of QCI6 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI6 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI6 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI6 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI6 E-RAB.

2.3.3.32 C373210339 Number of QCI6 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI6 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI6 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI6 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI6 E-RAB failed to
modify the QoS parameter is added to the counter.
2-108

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


occurs QCI6 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI6
E-RAB.

2.3.3.33 C373210340 Number of QCI6 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI6 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to waiting RRCConnectionReconfigurationComplete timer timeout,and
the the E-RAB failed to Modify List includes the QCI6 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI6 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI6 E-RAB.

2.3.3.34 C373210341 Number of QCI6 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI6 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-109
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI6 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI6 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger., and the
E-RAB Failed to Modify List includes the QCI6 E-RAB.

2.3.3.35 C373210342 Number of QCI6 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI6 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI6 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI6 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter
error,and the E-RAB Failed to Modify List includes the QCI6 E-RAB.

2.3.3.36 C373210343 Number of QCI6 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI6 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-110

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI6
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI6 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI6 E-RAB.

2.3.3.37 C373210344 Number of QCI7 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI7 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB to Setup List includes QCI7 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI7 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB to Setup List
includes the QCI7 E-RAB.

2.3.3.38 C373210345 Number of QCI7 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI7 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-111

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI7 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI7 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI7 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


occurs QCI7 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI7
E-RAB.

2.3.3.39 C373210346 Number of QCI7 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI7 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI7 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI7 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI7 E-RAB.

2-112
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.3.3.40 C373210347 Number of QCI7 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI7 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI7 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI7 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI7 E-RAB.

2.3.3.41 C373210348 Number of QCI7 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI7 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI7 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI7 E-RAB failed to modify the QoS
parameter is added to the counter.

2-113
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter error,
and the E-RAB Failed to Modify List includes the QCI7 E-RAB.

2.3.3.42 C373210349 Number of QCI7 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI7 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI7
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI7 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI7 E-RAB.

2.3.3.43 C373210350 Number of QCI8 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI8 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI8 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI8 E-RAB successfully modified the QoS
parameter is added to the counter.
2-114

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI8 E-RAB.

2.3.3.44 C373210351 Number of QCI8 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI8 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI8 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI8 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI8 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


occurs QCI8 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI8
E-RAB.

2.3.3.45 C373210352 Number of QCI8 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI8 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI8 E-RAB.
Sampling Point 5

2-115
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI8 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI8 E-RAB.

2.3.3.46 C373210353 Number of QCI8 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI8 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI8 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI8 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI8 E-RAB.

2.3.3.47 C373210354 Number of QCI8 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI8 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-116
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI8 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI8 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter
error,and the E-RAB Failed to Modify List includes the QCI8 E-RAB.

2.3.3.48 C373210355 Number of QCI8 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI8 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI8
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI8 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to other reason,and the E-RAB
Failed to Modify List includes the QCI8 E-RAB.

2.3.3.49 C373210356 Number of QCI9 SAE Bearers Successful Modification


Definition

The counter is used to count the number of QCI9 E-RABs successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-117

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and


the E-RAB Modify List IE includes QCI9 E-RAB.
Sampling Point 4.

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each QCI9 E-RAB successfully modified the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABModifyResponse to MME and the E-RAB Modify List IE
includes the QCI9 E-RAB.

2.3.3.50 C373210357 Number of QCI9 SAE Bearers Modification Failure due to ENB
Admission Failure
Definition

The counter is used to count the number of QCI9 E-RABs failed to be


modified the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs QCI9 E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the QCI9 E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each QCI9 E-RAB failed to
modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


occurs QCI9 E-RAB admission failures then sends E-RABModifyResponse
to MME, in which the E-RAB Failed to Modify List includes the QCI9
E-RAB.

2.3.3.51 C373210358 Number of QCI9 SAE Bearers Modification Failure due to Uu


Interface Failure
Definition

The counter is used to count the number of QCI9 E-RABs failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

2-118
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the QCI9 E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each QCI9 E-RAB
failed to modify the QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and the E-RAB Failed
to Modify List includes the QCI9 E-RAB.

2.3.3.52 C373210359 Number of QCI9 SAE Bearers Modification Failure due to


Handover Trigger
Definition

The counter is used to count the number of QCI9 E-RABs failed to be


modified the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
QCI9 E-RAB.
Sampling Point 4

Explanation

For handover, then sends a E-RAB MODIFY RESPONSE message to the


MME, in which each QCI9 E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to handover trigger, and the
E-RAB Failed to Modify List includes the QCI9 E-RAB.

2-119
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.3.3.53 C373210360 Number of QCI9 SAE Bearers Modification Failure due to


Parameter Error
Definition

The counter is used to count the number of QCI9 E-RABs failed to be


modified the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the QCI9 E-RAB.
Sampling Point 4

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each QCI9 E-RAB failed to modify the QoS
parameter is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABModifyResponse to MME due to message parameter error,
and the E-RAB Failed to Modify List includes the QCI9 E-RAB.

2.3.3.54 C373210361 Number of QCI9 SAE Bearers Modification Failure due to Other
Reason
Definition

The counter is used to count the number of QCI9 E-RABs failed to be


modified the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason,and the E-RAB failed to Modify List includes the QCI9
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each QCI9 E-RAB failed to modify the QoS parameter is
added to the counter.

2-120
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI9 E-RAB when eNodeB


sends E-RABModifyResponse message to MME due to other reason, and
the E-RAB Failed to Modify List includes the QCI9 E-RAB.

2.3.3.55 C373505393 Number of QCI1 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI1 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI1 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI1 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI1
E-RAB.

2.3.3.56 C373505394 Number of QCI2 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI2 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-121
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI2 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI2 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI2
E-RAB.

2.3.3.57 C373505395 Number of QCI3 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI3 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI3 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI3 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI3
E-RAB.

2-122
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.3.3.58 C373505396 Number of QCI4 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI4 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI4 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI4 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI4
E-RAB.

2.3.3.59 C373505397 Number of QCI5 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI5 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI5 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI5 E-RAB failed to an modify the QoS parameter message is added to
the counter.

2-123
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI5
E-RAB.

2.3.3.60 C373505398 Number of QCI6 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI6 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI6 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI6 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI6
E-RAB.

2.3.3.61 C373505399 Number of QCI7 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI7 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-124
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI7 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI7 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI7
E-RAB.

2.3.3.62 C373505400 Number of QCI8 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI8 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI8 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI8 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI8
E-RAB.

2-125
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.3.3.63 C373505401 Number of QCI9 SAE Bearers Modification Failure due to


Receiving RRC Re-establishment Request
Definition

The counter is used to count the number of QCI9 E-RABs failed to be


modified the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes QCI9 E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
QCI9 E-RAB failed to an modify the QoS parameter message is added to
the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the E-RABModifyResponse message to the MME due to RRC
re-establishment in which IE E-RAB Failed to Modify List includes QCI9
E-RAB.

2.3.3.64 C373505489 Number of SAE Bearers Successful Modification


Definition

The counter is used to count the number of E-RABs successfully modified


the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse to the MME, and the
E-RAB Modify List IE includes E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message, in which each E-RAB successfully modified the QoS parameter
is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABModifyResponse to MME and the E-RAB Modify List IE includes
the E-RAB.

2-126
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.3.3.65 C373505490 Number of SAE Bearers Modification Failure due to ENB


Admission Failure
Definition

The counter is used to count the number of E-RABs failed to be modified


the QoS parameter for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB occurs E-RAB admission failures then replies the
E-RABModifyResponse message to MME, in which the E-RAB failed to
Modify List includes the E-RAB.
Sampling Point 4

Explanation

On transmission by the eNodeB of an E-RAB MODIFY RESPONSE


message for admission failures, in which each E-RAB failed to modify the
QoS parameter is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB occurs


E-RAB admission failures then sends E-RABModifyResponse to MME, in
which the E-RAB Failed to Modify List includes the E-RAB.

2.3.3.66 C373505491 Number of SAE Bearers Modification Failure due to Uu Interface


Failure
Definition

The counter is used to count the number of E-RABs failed to be modified


the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to timeout of waiting for the RRCConnectionReconfigurationComplete
message,and the E-RAB failed to Modify List includes the E-RAB.
Sampling Point 5

Explanation

The timer expires for an expected RRCConnectionReconfigurationComplete message not received by the eNodeB,the eNodeB sends an E-RAB
MODIFY RESPONSE message to the MME, in which each E-RAB failed
to modify the QoS parameter is added to the counter.

2-127
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every E-RAB when eNodeB


sends E-RABModifyResponse to MME due to timeout of waiting for the
RRCConnectionReconfigurationComplete message,and E-RAB Failed
to Modify List includes the E-RAB.

2.3.3.67 C373505492 Number of SAE Bearers Modification Failure due to Handover


Trigger
Definition

The counter is used to count the number of E-RABs failed to be modified


the QoS parameter for handover trigger.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to handover trigger,and the E-RAB failed to Modify List includes the
E-RAB.
Sampling Point 4

Explanation

For handover, the eNodeB sends a E-RAB MODIFY RESPONSE message


to the MME, in which each E-RAB failed to modify the QoS parameter is
added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABModifyResponse to MME due to handover trigger, and the E-RAB
Failed to Modify List includes the E-RAB.

2.3.3.68 C373505493 Number of SAE Bearers Modification Failure due to Parameter


Error
Definition

The counter is used to count the number of E-RABs failed to be modified


the QoS parameter for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to message parameter error, and the E-RAB failed to Modify List
includes the E-RAB.
Sampling Point 4

2-128
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When the eNodeB receives the E-RABModifyRequest message from


the MME, then replies an E-RAB MODIFY RESPONSE message for
parameter error, in which each E-RAB failed to modify the QoS parameter
is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABModifyResponse to MME due to message parameter error,and the
E-RAB Failed to Modify List includes the E-RAB.

2.3.3.69 C373505494 Number of SAE Bearers Modification Failure due to Receiving


RRC Re-establishment Request
Definition

The counter is used to count the number of E-RABs failed to be modified


the QoS parameter for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABModifyResponse message to the


MME due to RRC re-establishment in which IE E-RAB Failed to Modify
List includes E-RABs.
Sampling Point 4

Explanation

For receiving the RRCConnectionReestablishmentRequest message, the


eNodeB sends E-RAB MODIFY RESPONSE message to the MME.each
E-RAB failed to an modify the QoS parameter message is added to the
counter.

Updated

The counter is incremented by 1 for every E-RAB When the eNodeB


sends the E-RABModifyResponse message to the MME due to RRC
re-establishment and the E-RAB Failed to Modify List includes the E-RAB.

2.3.3.70 C373505495 Number of SAE Bearers Modification Failure due to Other Reason
Definition

The counter is used to count the number of E-RABs failed to be modified


the QoS parameter for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-129
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB replies the E-RABModifyResponse message to MME


due to other reason, and the E-RAB failed to Modify List includes the
E-RAB.

Explanation

When the eNodeB receives the E-RABModifyRequest message from the


MME, then replies an E-RAB MODIFY RESPONSE message for other
reason, in which each E-RAB failed to modify the QoS parameter is added
to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends


E-RABModifyResponse to MME due to other reason,and the E-RAB Failed
to Modify List includes the E-RAB.

2.4 E-RAB Release


2.4.1 Flow Charts and Sampling Points
Figure 2-4 E-RAB Release

Sampling Point 1: The EUTRAN receives the E-RAB RELEASE COMMAND message
from the MME.
2-130

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

l
l
l
l
l
l

Sampling Point 2: The EUTRAN sends the E-RAB RELEASE RESPONSE message
to the MME, indicating that the E-RAB Release has been successful.
Sampling Point 3: The EUTRAN sends the E-RAB RELEASE INDICATION message
to the MME.
Sampling Point 4: The EUTRAN sends the UE Context ReleaseRequest message to
the MME.
Sampling Point 5: The EUTRAN receives the UE Context ReleaseCommand
message from the MME.
Sampling Point 6: The EUTRAN receives the RESET message from the MME.
Sampling Point 7: The EUTRAN receives the Error Indication message from the MME.

2.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373210362

Number of QCI1 E-RAB Release by MME Normal Release

C373210363

Number of QCI2 E-RAB Release by MME Normal Release

C373210364

Number of QCI3 E-RAB Release by MME Normal Release

C373210365

Number of QCI4 E-RAB Release by MME Normal Release

C373210366

Number of QCI5 E-RAB Release by MME Normal Release

C373210367

Number of QCI6 E-RAB Release by MME Normal Release

C373210368

Number of QCI7 E-RAB Release by MME Normal Release

C373210369

Number of QCI8 E-RAB Release by MME Normal Release

C373210370

Number of QCI9 E-RAB Release by MME Normal Release

10

C373210371

Number of E-RAB Release by MME Normal Release

11

C373210372

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

12

C373210373

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

13

C373210374

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

14

C373210375

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

15

C373210376

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

16

C373210377

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

17

C373210378

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control
2-131

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
18

C373210379

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

19

C373210380

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control

20

C373210381

Number of E-RAB Release by ENB Through E-RAB Release Procedure due


to Overload Control

21

C373210382

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

22

C373210383

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

23

C373210384

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

24

C373210385

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

25

C373210386

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

26

C373210387

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

27

C373210388

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

28

C373210389

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

29

C373210390

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason

30

C373210391

Number of E-RAB Release by ENB Through E-RAB Release Procedure due


to Other Abnormal Reason

31

C373210422

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

32

C373210423

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

33

C373210424

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

34

C373210425

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

35

C373210426

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

2-132
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
36

C373210427

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

37

C373210428

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

38

C373210429

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

39

C373210430

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail

40

C373210431

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to HO Fail

41

C373210432

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

42

C373210433

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

43

C373210434

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

44

C373210435

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

45

C373210436

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

46

C373210437

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

47

C373210438

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

48

C373210439

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

49

C373210440

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure

50

C373210441

Number of E-RAB Release by ENB Through E-RAB Release Procedure due


to Radio Link Failure

51

C373210442

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

52

C373210443

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

53

C373210444

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

2-133
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
54

C373210445

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

55

C373210446

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

56

C373210447

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

57

C373210448

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

58

C373210449

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

59

C373210450

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail

60

C373210451

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to Reestablish Fail

61

C373210492

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

62

C373210493

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

63

C373210494

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

64

C373210495

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

65

C373210496

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

66

C373210497

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

67

C373210498

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

68

C373210499

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

69

C373210500

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive

70

C373210501

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to UserInactive

71

C373210502

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

2-134
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
72

C373210503

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

73

C373210504

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

74

C373210505

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

75

C373210506

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

76

C373210507

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

77

C373210508

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

78

C373210509

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

79

C373210510

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset

80

C373210511

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to Cell Block or Reset

81

C373210512

Number of QCI1 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

82

C373210513

Number of QCI2 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

83

C373210514

Number of QCI3 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

84

C373210515

Number of QCI4 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

85

C373210516

Number of QCI5 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

86

C373210517

Number of QCI6 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

87

C373210518

Number of QCI7 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

88

C373210519

Number of QCI8 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

89

C373210520

Number of QCI9 E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB

2-135
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
90

C373210521

Number of E-RAB Release by MME due to Error Indication or Reestablish


Inter eNB

91

C373210522

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

92

C373210523

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

93

C373210524

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

94

C373210525

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

95

C373210526

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

96

C373210527

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

97

C373210528

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

98

C373210529

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

99

C373210530

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection

100

C373210531

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to Redirection

101

C373505309

Number of QCI1 E-RAB Failed to Release

102

C373505310

Number of QCI2 E-RAB Failed to Release

103

C373505311

Number of QCI3 E-RAB Failed to Release

104

C373505312

Number of QCI4 E-RAB Failed to Release

105

C373505313

Number of QCI5 E-RAB Failed to Release

106

C373505314

Number of QCI6 E-RAB Failed to Release

107

C373505315

Number of QCI7 E-RAB Failed to Release

108

C373505316

Number of QCI8 E-RAB Failed to Release

109

C373505317

Number of QCI9 E-RAB Failed to Release

110

C373505318

Number of QCI1 E-RAB Attempted to Release

111

C373505319

Number of QCI2 E-RAB Attempted to Release

112

C373505320

Number of QCI3 E-RAB Attempted to Release

2-136
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
113

C373505321

Number of QCI4 E-RAB Attempted to Release

114

C373505322

Number of QCI5 E-RAB Attempted to Release

115

C373505323

Number of QCI6 E-RAB Attempted to Release

116

C373505324

Number of QCI7 E-RAB Attempted to Release

117

C373505325

Number of QCI8 E-RAB Attempted to Release

118

C373505326

Number of QCI9 E-RAB Attempted to Release

119

C373505345

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

120

C373505346

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

121

C373505347

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

122

C373505348

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

123

C373505349

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

124

C373505350

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

125

C373505351

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

126

C373505352

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

127

C373505353

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error

128

C373505354

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to S1 Link Error

129

C373505355

Number of QCI1 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

130

C373505356

Number of QCI2 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

131

C373505357

Number of QCI3 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

132

C373505358

Number of QCI4 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

2-137
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
133

C373505359

Number of QCI5 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

134

C373505360

Number of QCI6 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

135

C373505361

Number of QCI7 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

136

C373505362

Number of QCI8 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

137

C373505363

Number of QCI9 E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause

138

C373505364

Number of E-RAB Release by ENB Through E-RAB Release Procedure


due to CCO Cause

139

C373505452

Number of QCI1 E-RAB Release by ENB due to UE off-line

140

C373505453

Number of QCI2 E-RAB Release by ENB due to UE off-line

141

C373505454

Number of QCI3 E-RAB Release by ENB due to UE off-line

142

C373505455

Number of QCI4 E-RAB Release by ENB due to UE off-line

143

C373505456

Number of QCI5 E-RAB Release by ENB due to UE off-line

144

C373505457

Number of QCI6 E-RAB Release by ENB due to UE off-line

145

C373505458

Number of QCI7 E-RAB Release by ENB due to UE off-line

146

C373505459

Number of QCI8 E-RAB Release by ENB due to UE off-line

147

C373505460

Number of QCI9 E-RAB Release by ENB due to UE off-line

148

C373505461

Number of E-RAB Release by ENB due to UE off-line

149

C373505462

Number of QCI1 E-RAB Release by MME due to Other Reason

150

C373505463

Number of QCI2 E-RAB Release by MME due to Other Reason

151

C373505464

Number of QCI3 E-RAB Release by MME due to Other Reason

152

C373505465

Number of QCI4 E-RAB Release by MME due to Other Reason

153

C373505466

Number of QCI5 E-RAB Release by MME due to Other Reason

154

C373505467

Number of QCI6 E-RAB Release by MME due to Other Reason

155

C373505468

Number of QCI7 E-RAB Release by MME due to Other Reason

156

C373505469

Number of QCI8 E-RAB Release by MME due to Other Reason

157

C373505470

Number of QCI9 E-RAB Release by MME due to Other Reason

158

C373505471

Number of E-RAB Release by MME due to Other Reason

159

C373505496

Number of E-RAB Attempted to Release

2-138
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
160

C373505497

Number of E-RAB Failed to Release

161

C373505499

Number of Abnormal Release Active ERAB

2.4.3 Counter Description


2.4.3.1 C373210362 Number of QCI1 E-RAB Release by MME Normal Release
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI1 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI1 E-RABs release successful initiated
by MME is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI1 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.2 C373210363 Number of QCI2 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

2-139
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI2 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI2 E-RABs release successful initiated
by MME is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI2 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.3 C373210364 Number of QCI3 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI3 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI3 E-RABs release successful initiated
by MME is added to the counter.

2-140
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI3 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.4 C373210365 Number of QCI4 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI4 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI4 E-RABs release successful initiated
by MME is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI4 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.5 C373210366 Number of QCI5 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
2-141

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI5 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI5 E-RABs release successful initiated
by MME is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI5 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.6 C373210367 Number of QCI6 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI6 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI6 E-RABs release successful initiated
by MME is added to the counter.

2-142
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI6 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.7 C373210368 Number of QCI7 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI7 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI7 E-RABs release successful initiated
by MME is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI7 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.8 C373210369 Number of QCI8 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
2-143

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI8 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI8 E-RABs release successful initiated
by MME is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI8 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.9 C373210370 Number of QCI9 E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the QCI9 E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, Sampling Point 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above QCI9 E-RABs release successful initiated
by MME is added to the counter.

2-144
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies the
E-RAB RELEASE RESPONSE message to MME, and in which IE E-RAB
To Be Released List includes the QCI9 E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.10 C373210371 Number of E-RAB Release by MME Normal Release


Definition

The counter is used to count the number of E-RABs requested to release


initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RABReleaseCommand message from


MME then replies the E-RAB RELEASE RESPONSE message to MME,
and in which IE E-RAB To Be Released List includes the E-RAB. Or
When the eNodeB receives the UEContextReleaseCommand message
from the MME.
Sampling Point 2, 5

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME, in which the Cause is
"Normal Relase", "Detach"," Authentication failure" or" Interaction with
other procedure". Each above E-RABs release successful initiated by
MME is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RABReleaseCommand message from MME then replies
the E-RAB RELEASE RESPONSE message to MME, and in which IE
E-RAB To Be Released List includes the E-RAB. Or When the eNodeB
receives the UEContextReleaseCommand message from the MME.

2.4.3.11 C373210372 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-145

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI1 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI1 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI1 E-RAB.

2.4.3.12 C373210373 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI2 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI2 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI2 E-RAB.

2.4.3.13 C373210374 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for detecting cell overload.
2-146

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI3 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI3 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI3 E-RAB.

2.4.3.14 C373210375 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI4 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI4 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI4 E-RAB.

2-147
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.15 C373210376 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI5 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI5 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI5 E-RAB.

2.4.3.16 C373210377 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI6 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI6 E-RAB is released for above reason,it is added to the counter.

2-148
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI6 E-RAB.

2.4.3.17 C373210378 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI7 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI7 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI7 E-RAB.

2.4.3.18 C373210379 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-149
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI8 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI8 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI8 E-RAB.

2.4.3.19 C373210380 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to Overload Control
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload,and the E-RAB To Be Released List includes
the QCI9 E-RAB.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
QCI9 E-RAB is released for above reason,it is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when eNodeB sends
the E-RAB RELEASE INDICATION message or UE Context Release
Request to the MME due to LoadControl,and the E-RAB released List
includes the QCI9 E-RAB.

2.4.3.20 C373210381 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to Overload Control
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for detecting cell overload.

Sampling Interval

Event triggered
2-150

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to detection overload.
Sampling Point 3

Explanation

In the condition of opening "Load Control" switch,the eNodeB trigger the


some appropriate traffics to release when detecting cell overloading.When
a E-RAB is released for above reason, it is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when eNodeB sends the
E-RAB RELEASE INDICATION message or UE Context Release Request
to the MME due to LoadControl.

2.4.3.21 C373210382 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI1
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI1 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI1 E-RAB.

2.4.3.22 C373210383 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for other reason.

2-151
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI2
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI2 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI2 E-RAB.

2.4.3.23 C373210384 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI3
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI3 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI3 E-RAB.

2-152
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.24 C373210385 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI4
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI4 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI4 E-RAB.

2.4.3.25 C373210386 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI5
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI5 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI5 E-RAB.

2-153
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.26 C373210387 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI6
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI6 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI6 E-RAB.

2.4.3.27 C373210388 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI7
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI7 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI7 E-RAB.

2-154
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.28 C373210389 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI8
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI8 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI8 E-RAB.

2.4.3.29 C373210390 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason,and the E-RAB To Be Released List includes the QCI9
E-RAB.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above QCI9 E-RABs initiated by eNodeB is added
to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other
reason,and the E-RAB To Be Released List includes the QCI9 E-RAB.

2-155
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.30 C373210391 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to Other Abnormal Reason
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to other reason.
Sampling Point 3

Explanation

For other reason, the eNodeB sends the E-RABReleaseIndication


message to MME. Each above E-RABs initiated by eNodeB is added to
the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to other reason.

2.4.3.31 C373210422 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2-156
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.32 C373210423 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2.4.3.33 C373210424 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2-157
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.34 C373210425 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2.4.3.35 C373210426 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2-158
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.36 C373210427 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2.4.3.37 C373210428 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2-159
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.38 C373210429 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger QCI8 E-RAB


realese due to handover failures.

2.4.3.39 C373210430 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to HO Fail
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the corresponding
QCI E-RAB release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the


corresponding QCI E-RAB release due to handover failures.

2-160
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.40 C373210431 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to HO Fail
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB trigger E-RAB release due to UE handover failures.


Sampling Point 5

Explanation

A UE is released by the source eNodeB due to an expected


UEContextReleaseCommand or UEContextRelease message indicating
handover complete not received by the eNodeB. Each of the E-RAB
release is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB trigger the E-RAB


release due to handover failures.

2.4.3.41 C373210432 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI1 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

2-161
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures, and the E-RAB To Be Released List includes the QCI1 E-RAB.

2.4.3.42 C373210433 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI2 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI2 E-RAB.

2.4.3.43 C373210434 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-162
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI3 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI3 E-RAB.

2.4.3.44 C373210435 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI4 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI4 E-RAB.

2-163
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.45 C373210436 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI5 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI5 E-RAB.

2.4.3.46 C373210437 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI6 E-RAB.
Sampling Point 3

2-164
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI6 E-RAB.

2.4.3.47 C373210438 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI7 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI7 E-RAB.

2-165
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.48 C373210439 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI8 E-RAB.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI8 E-RAB.

2.4.3.49 C373210440 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to Radio Link Failure
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures,and the E-RAB To Be Released List includes
the QCI9 E-RAB.
Sampling Point 3

2-166
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseIndication message to MME due to radio link
failures,and the E-RAB To Be Released List includes the QCI9 E-RAB.

2.4.3.50 C373210441 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to Radio Link Failure
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseIndication message to MME


due to radio link failures.
Sampling Point 3

Explanation

When a RLC PDU is transfered then exceeded the maximum number on


the downlink, it is regarded as RLF.
When eNodeB's timer expires that monitoring the message
from the UE to eNodeB, it is regarded as RLF. For example,
the RRCConnectionReestablishmentComplete message, the
RRCConnectionReconfigurationComplete message and so on.
When a SR is transfered then exceeded the maximum number,it is
regarded as RLF.

Updated

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the E-RABReleaseIndication message to MME due to radio link failures.

2.4.3.51 C373210442 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for re-establishment failures.
2-167

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI1 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI1 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI1 E-RAB.

2.4.3.52 C373210443 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI2 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI2 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI2 E-RAB.

2-168
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.53 C373210444 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI3 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI3 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI3 E-RAB.

2.4.3.54 C373210445 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI4 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI4 E-RAB released is added to the counter.
2-169

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI4 E-RAB.

2.4.3.55 C373210446 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI5 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI5 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI5 E-RAB.

2.4.3.56 C373210447 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-170
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI6 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI6 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI6 E-RAB.

2.4.3.57 C373210448 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI7 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI7 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI7 E-RAB.

2-171
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.58 C373210449 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI8 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI8 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI8 E-RAB.

2.4.3.59 C373210450 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to Reestablish Fail
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures,and the E-RAB To
Be Released List includes the QCI9 E-RAB.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above QCI9 E-RAB released is added to the counter.
2-172

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to RRC
connection reestablishment failures,and the UE has the QCI9 E-RAB.

2.4.3.60 C373210451 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to Reestablish Fail
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to RRC connection reestablishment failures.
Sampling Point 4

Explanation

Transmission of a UE CONTEXT RELEASE REQUEST message by the


eNodeB to the MME when eNodeB occur RRC connection reestablishment
failures then sends the RRCConnectionReestablishmentReject message
to the UE.
Each above E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the UeContextReleaseRequest message to MME due to RRC connection
reestablishment failures.

2.4.3.61 C373210492 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI1 E-RAB.
Sampling Point 4

2-173
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI1 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI1 E-RAB.

2.4.3.62 C373210493 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI2 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI2 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI2 E-RAB.

2.4.3.63 C373210494 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-174
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI3 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI3 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI3 E-RAB.

2.4.3.64 C373210495 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI4 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI4 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI4 E-RAB.

2.4.3.65 C373210496 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

2-175
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI5 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI5 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI5 E-RAB.

2.4.3.66 C373210497 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI6 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI6 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI6 E-RAB.

2.4.3.67 C373210498 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for user inactive.

2-176
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI7 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI7 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI7 E-RAB.

2.4.3.68 C373210499 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI8 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI8 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI8 E-RAB.

2-177
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.69 C373210500 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to UserInactive
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to user inactive,and the UE has QCI9 E-RAB.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition QCI9 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to user
inactive,and the UE has QCI9 E-RAB.

2.4.3.70 C373210501 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to UserInactive
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the UeContextReleaseRequest message to MME due to user inactive.
Sampling Point 4

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".
Each above condition E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the UeContextReleaseRequest message to MME due to user inactive.

2-178
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.71 C373210502 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or Reset,and the UE has QCI1 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI1 E-RAB.

2.4.3.72 C373210503 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI2 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI2 E-RAB.

2-179
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.73 C373210504 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI3 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm that trigger UE release.
Each above two conditions QCI3 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI3 E-RAB.

2.4.3.74 C373210505 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI4 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI4 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI4 E-RAB.

2-180
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.75 C373210506 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI5 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI5 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI5 E-RAB.

2.4.3.76 C373210507 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI6 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI6 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI6 E-RAB.

2-181
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.77 C373210508 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI7 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI7 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI7 E-RAB.

2.4.3.78 C373210509 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI8 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI8 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI8 E-RAB.

2-182
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.79 C373210510 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to cell block or reset,and the UE has QCI9 E-RAB.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions QCI9 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to cell block
or reset,and the UE has QCI9 E-RAB.

2.4.3.80 C373210511 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to Cell Block or Reset
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for cell block or reset.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the UeContextReleaseRequest message to MME due to cell block or reset.
Sampling Point 4

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm about cell that trigger UE release.
Each above two conditions E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the UeContextReleaseRequest message to MME due to cell block or reset.

2-183
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.81 C373210512 Number of QCI1 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of QCI1 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.

Updated

The counter is incremented by the number of QCI1 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.82 C373210513 Number of QCI2 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

2-184
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

The counter is used to count the number of QCI2 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI2 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.83 C373210514 Number of QCI3 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of QCI3 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI3 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2-185
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.84 C373210515 Number of QCI4 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of QCI4 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI4 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.85 C373210516 Number of QCI5 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7
2-186

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

The counter is used to count the number of QCI5 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI5 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.86 C373210517 Number of QCI6 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of QCI6 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI6 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2-187
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.87 C373210518 Number of QCI7 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of QCI7 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI7 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.88 C373210519 Number of QCI8 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7
2-188

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

The counter is used to count the number of QCI8 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI8 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.89 C373210520 Number of QCI9 E-RAB Release by MME due to Error Indication
or Reestablish Inter eNB
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of QCI9 E-RABs Release initiated
by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of QCI9 E-RABs


released when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2-189
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.90 C373210521 Number of E-RAB Release by MME due to Error Indication or


Reestablish Inter eNB
Definition

The counter is used to count the number of E-RABs requested to release


initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 5, Sampling Point 7

Explanation

The counter is used to count the number of E-RABs Release initiated by


MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context.
The eNodeB receives the ErrorIndication message from the MME, then
release the UE Context.
.

Updated

The counter is incremented by the number of E-RABs released


when the eNodeB receives the ErrorIndication message or
UEContextReleaseCommand message from the MME.

2.4.3.91 C373210522 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI1 E-RAB.
Sampling Point 4

2-190
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI1 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI1 E-RAB.

2.4.3.92 C373210523 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI2 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI2 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI2 E-RAB.

2.4.3.93 C373210524 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-191
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI3 E-RAB.
Sampling Point 4

Explanation

The eNodeB concludes UE When the eNodeB concludes UE redirection to


other cell, it sends the UeContextReleaseRequest message to MME after
sending the RRCConnectionRelease message to UE. Each above QCI3
E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI3 E-RAB.

2.4.3.94 C373210525 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI4 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI4 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI4 E-RAB.

2.4.3.95 C373210526 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

2-192
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI5 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI5 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI5 E-RAB.

2.4.3.96 C373210527 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI6 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI6 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI6 E-RAB.

2.4.3.97 C373210528 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for redirection.

2-193
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI7 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI7 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI7 E-RAB.

2.4.3.98 C373210529 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI8 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI8 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI8 E-RAB.

2-194
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.99 C373210530 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to Redirection
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection,and the UE has QCI9 E-RAB.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above QCI9 E-RAB
released is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the


eNodeB sends the UeContextReleaseRequest message to MME due to
redirection,and the UE has QCI9 E-RAB.

2.4.3.100 C373210531 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to Redirection
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UeContextReleaseRequest message to


MME due to UE redirection.
Sampling Point 4

Explanation

When the eNodeB concludes UE redirection to other cell, it sends


the UeContextReleaseRequest message to MME after sending the
RRCConnectionRelease message to UE. Each above E-RAB released is
added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the UeContextReleaseRequest message to MME due to redirection.

2-195
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.101 C373505309 Number of QCI1 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI1 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI1 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI1 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI1 E-RAB.

2.4.3.102 C373505310 Number of QCI2 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI2 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI2 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI2 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI2 E-RAB.

2.4.3.103 C373505311 Number of QCI3 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI3 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit
2-196

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI3 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI3 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI3 E-RAB.

2.4.3.104 C373505312 Number of QCI4 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI4 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI4 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI4 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI4 E-RAB.

2.4.3.105 C373505313 Number of QCI5 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI5 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI5 E-RAB.
Sampling Point 2

2-197
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI5 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI5 E-RAB.

2.4.3.106 C373505314 Number of QCI6 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI6 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI6 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI6 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI6 E-RAB.

2.4.3.107 C373505315 Number of QCI7 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI7 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI7 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI7 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI7 E-RAB.

2-198
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.108 C373505316 Number of QCI8 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI8 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI8 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI8 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI8 E-RAB.

2.4.3.109 C373505317 Number of QCI9 E-RAB Failed to Release


Definition

The counter is used to count the number of QCI9 E-RABs failed to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the QCI9 E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each QCI9 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the QCI9 E-RAB.

2.4.3.110 C373505318 Number of QCI1 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI1 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-199

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI1
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI1 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI1 E-RAB.

2.4.3.111 C373505319 Number of QCI2 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI2 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI2
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI2 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI2 E-RAB.

2.4.3.112 C373505320 Number of QCI3 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI3 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
2-200

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI3
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI3 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI3 E-RAB.

2.4.3.113 C373505321 Number of QCI4 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI4 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI4
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI4 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RABs attempted to release includes the QCI4 E-RAB.

2.4.3.114 C373505322 Number of QCI5 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI5 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-201
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI5
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI5 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI5 E-RAB.

2.4.3.115 C373505323 Number of QCI6 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI6 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI6
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI6 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI6 E-RAB.

2.4.3.116 C373505324 Number of QCI7 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI7 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-202
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI7
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI7 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI7 E-RAB.

2.4.3.117 C373505325 Number of QCI8 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI8 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI8
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI8 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI8 E-RAB.

2.4.3.118 C373505326 Number of QCI9 E-RAB Attempted to Release


Definition

The counter is used to count the number of QCI9 E-RABs attempted to


release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-203
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the QCI9
E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each QCI9 E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the QCI9 E-RAB.

2.4.3.119 C373505345 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.120 C373505346 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

2-204
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI2 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.121 C373505347 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI3 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2-205
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.122 C373505348 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


1 The eNodeB detects the fibber warning.
2 The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
3 The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI4 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.123 C373505349 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

2-206
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every QCI5 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.124 C373505350 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI6 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.125 C373505351 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

2-207
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI7 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.126 C373505352 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
3The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI8 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.127 C373505353 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to S1 Link Error
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

2-208
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every QCI9 E-RAB When the eNodeB
sends the UE Context ReleaseRequest message to the MME due to S1
link fault.

2.4.3.128 C373505354 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to S1 Link Error
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to S1 link fault.
Sampling Point 4

Explanation

The S1 link fault refer to the following.


The eNodeB detects the fibber warning.
The eNodeB gtpu layer detects the path fault from the eNodeB to SGW.
The eNodeB gtpu layer receives the ErrorIndication message from the
SGW.

Updated

The counter is incremented by 1 for every E-RAB When the eNodeB sends
the UE Context ReleaseRequest message to the MME due to S1 link fault.

2.4.3.129 C373505355 Number of QCI1 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered
2-209

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI1 E-RABs.
Sampling Point 4.

Explanation

The QCI1 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.130 C373505356 Number of QCI2 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI2 E-RABs.
Sampling Point 4.

Explanation

The QCI2 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.131 C373505357 Number of QCI3 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
2-210

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI3 E-RABs.
Sampling Point 4.

Explanation

The QCI3 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.132 C373505358 Number of QCI4 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI4 E-RABs.
Sampling Point 4.

Explanation

The QCI4 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.133 C373505359 Number of QCI5 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI5 E-RABs.
Sampling Point 4.

2-211
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The QCI5 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.134 C373505360 Number of QCI6 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI6 E-RABs.
Sampling Point 4.

Explanation

The QCI6 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.135 C373505361 Number of QCI7 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI7 E-RABs.
Sampling Point 4.

Explanation

The QCI7 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.
2-212

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.4.3.136 C373505362 Number of QCI8 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI8 E-RABs.
Sampling Point 4.

Explanation

The QCI8 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.137 C373505363 Number of QCI9 E-RAB Release by ENB Through E-RAB Release
Procedure due to CCO Cause
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to the


MME due to CCO and the User has QCI9 E-RABs.
Sampling Point 4.

Explanation

The QCI9 E-RABs requested to be released by eNodeB due to CCO are


added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB when the eNodeB
sends the UE Context ReleaseRequest message to the MME due to CCO.

2-213
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.138 C373505364 Number of E-RAB Release by ENB Through E-RAB Release


Procedure due to CCO Cause
Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to


the MME due to CCO.
Sampling Point 4

Explanation

The E-RABs requested to be released by eNodeB due to CCO are added


to the counter.

Updated

The counter is incremented by 1 for every E-RAB when the eNodeB sends
the UE Context ReleaseRequest message to the MME due to CCO.

2.4.3.139 C373505452 Number of QCI1 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI1 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI1 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI1 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.140 C373505453 Number of QCI2 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.
2-214

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI2 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI2 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI2 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.141 C373505454 Number of QCI3 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI3 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI3 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI3 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.142 C373505455 Number of QCI4 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-215

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI4 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI4 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI4 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.143 C373505456 Number of QCI5 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI5 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI5 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI5 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.144 C373505457 Number of QCI6 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
2-216

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI6 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI6 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI6 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.145 C373505458 Number of QCI7 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI7 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI7 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI7 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.146 C373505459 Number of QCI8 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-217
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI8 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI8 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI8 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.147 C373505460 Number of QCI9 E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to the


MME due to Radio Connection With UE Lost and the UE has QCI9 E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above QCI9 E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every QCI9 E-RAB When the eNodeB
sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.148 C373505461 Number of E-RAB Release by ENB due to UE off-line


Definition

The counter is used to count the number of E-RABs requested to release


initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-218
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the eNodeB sends the UE ContextReleaseRequest message to


the MME due to Radio Connection With UE Lost and the UE has QCI10
E-RAB.
Sampling Point 4

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm.


If the UE's state is concluded as offline, the eNodeB will trigger UE
release.Each above E-RAB released is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB When the eNodeB


sends the UE ContextReleaseRequest message to the MME due to Radio
Connection With UE Lost.

2.4.3.149 C373505462 Number of QCI1 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI1 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI1 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI1 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.150 C373505463 Number of QCI2 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI2 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

2-219
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI2 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI2 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.151 C373505464 Number of QCI3 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI3 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI3 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI3 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.152 C373505465 Number of QCI4 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI4 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-220

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI4 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI4 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.153 C373505466 Number of QCI5 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI5 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI5 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI5 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.154 C373505467 Number of QCI6 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI6 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered
2-221

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI6 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI6 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.155 C373505468 Number of QCI7 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI7 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI7 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI7 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.156 C373505469 Number of QCI8 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI8 E-RABs requested to


release initiated by MME for other reason.
2-222

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI8 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI8 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.157 C373505470 Number of QCI9 E-RAB Release by MME due to Other Reason
Definition

The counter is used to count the number of QCI9 E-RABs requested to


release initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of QCI9 E-RABs
Release initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI9 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2-223
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.4.3.158 C373505471 Number of E-RAB Release by MME due to Other Reason


Definition

The counter is used to count the number of E-RABs requested to release


initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from the MME.

Explanation

The eNodeB receives the UEContextReleaseCommand or


E-RABReleaseCommand message from MME, in which the Cause
excludes Normal Release, Detach , Authentication failure, Interaction with
other procedure,Successful Handover and Failure in the Radio Interface
Procedure. The counter is used to count the number of E-RABs Release
initiated by MME due to the above condition.

Updated

The counter is incremented by the number of QCI1 E-RAB released


when the eNodeB receives the UEContextReleaseCommand or
E-RABReleaseCommand message from the MME.

2.4.3.159 C373505496 Number of E-RAB Attempted to Release


Definition

The counter is used to count the number of E-RABs attempted to release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the E-RAB RELEASE COMMAND message


from the MME in which IE:E-RAB To Be Released List includes the E-RAB.
Sampling Point 1

Explanation

On receipt by the eNodeB of an E-RAB RELEASE COMMAND message


from MME, each E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
receives the E-RAB RELEASE COMMAND message from the MME in
which IE:E-RAB To Be Released List includes the E-RAB.

2.4.3.160 C373505497 Number of E-RAB Failed to Release


Definition

The counter is used to count the number of E-RABs failed to release.


2-224

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the E-RABReleaseReponse message to the


MME, and IE E-RABs Failed to Release List include the E-RAB.
Sampling Point 2

Explanation

On transmission by the eNodeB of an E-RAB RELEASE RESPONSE


message, each E-RAB failed to release is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the eNodeB
sends the E-RABReleaseReponse message to the MME, and IE E-RABs
Failed to Release List include the E-RAB.

2.4.3.161 C373505499 Number of Abnormal Release Active ERAB


Definition

The counter is used to count the number of released E-RABs that were
active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a E-RAB with data in a buffer that


was abnormally released.

2.5 E-RAB Handover


2.5.1 Flow Charts and Sampling Points
No chart.

2-225
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.2 Counter List


NO.

Counter

Counter Name

Number
1

C373210452

Number of Successful E-RAB(QCI1) HO Incoming

C373210453

Number of Successful E-RAB(QCI2) HO Incoming

C373210454

Number of Successful E-RAB(QCI3) HO Incoming

C373210455

Number of Successful E-RAB(QCI4) HO Incoming

C373210456

Number of Successful E-RAB(QCI5) HO Incoming

C373210457

Number of Successful E-RAB(QCI6) HO Incoming

C373210458

Number of Successful E-RAB(QCI7) HO Incoming

C373210459

Number of Successful E-RAB(QCI8) HO Incoming

C373210460

Number of Successful E-RAB(QCI9) HO Incoming

10

C373210461

Number of Successful E-RAB HO Incoming

11

C373210462

Number of Successful E-RAB(QCI1) HO Outgoing

12

C373210463

Number of Successful E-RAB(QCI2) HO Outgoing

13

C373210464

Number of Successful E-RAB(QCI3) HO Outgoing

14

C373210465

Number of Successful E-RAB(QCI4) HO Outgoing

15

C373210466

Number of Successful E-RAB(QCI5) HO Outgoing

16

C373210467

Number of Successful E-RAB(QCI6) HO Outgoing

17

C373210468

Number of Successful E-RAB(QCI7) HO Outgoing

18

C373210469

Number of Successful E-RAB(QCI8) HO Outgoing

19

C373210470

Number of Successful E-RAB(QCI9) HO Outgoing

20

C373210471

Number of Successful E-RAB HO Outgoing

21

C373210472

Number of E-RAB(QCI1) HO Incoming Admission Request

22

C373210473

Number of E-RAB(QCI2) HO Incoming Admission Request

23

C373210474

Number of E-RAB(QCI3) HO Incoming Admission Request

24

C373210475

Number of E-RAB(QCI4) HO Incoming Admission Request

25

C373210476

Number of E-RAB(QCI5) HO Incoming Admission Request

26

C373210477

Number of E-RAB(QCI6) HO Incoming Admission Request

27

C373210478

Number of E-RAB(QCI7) HO Incoming Admission Request

28

C373210479

Number of E-RAB(QCI8) HO Incoming Admission Request

29

C373210480

Number of E-RAB(QCI9) HO Incoming Admission Request

30

C373210481

Number of E-RAB HO Incoming Admission Request

31

C373210482

Number of E-RAB(QCI1) HO Incoming Admission Fail


2-226

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

NO.

Counter

Counter Name

Number
32

C373210483

Number of E-RAB(QCI2) HO Incoming Admission Fail

33

C373210484

Number of E-RAB(QCI3) HO Incoming Admission Fail

34

C373210485

Number of E-RAB(QCI4) HO Incoming Admission Fail

35

C373210486

Number of E-RAB(QCI5) HO Incoming Admission Fail

36

C373210487

Number of E-RAB(QCI6) HO Incoming Admission Fail

37

C373210488

Number of E-RAB(QCI7) HO Incoming Admission Fail

38

C373210489

Number of E-RAB(QCI8) HO Incoming Admission Fail

39

C373210490

Number of E-RAB(QCI9) HO Incoming Admission Fail

40

C373210491

Number of HO Incoming Admission Fail

41

C373546248

Number of Successful E-RAB(QCI1) Re-Establishment Incoming

42

C373546249

Number of Successful E-RAB(QCI2) Re-Establishment Incoming

43

C373546250

Number of Successful E-RAB(QCI3) Re-Establishment Incoming

44

C373546251

Number of Successful E-RAB(QCI4) Re-Establishment Incoming

45

C373546252

Number of Successful E-RAB(QCI5) Re-Establishment Incoming

46

C373546253

Number of Successful E-RAB(QCI6) Re-Establishment Incoming

47

C373546254

Number of Successful E-RAB(QCI7) Re-Establishment Incoming

48

C373546255

Number of Successful E-RAB(QCI8) Re-Establishment Incoming

49

C373546256

Number of Successful E-RAB(QCI9) Re-Establishment Incoming

50

C373546257

Number of Successful E-RAB Re-Establishment Incoming

51

C373546258

Number of Successful E-RAB(QCI1) Re-Establishment Outgoing

52

C373546259

Number of Successful E-RAB(QCI2) Re-Establishment Outgoing

53

C373546260

Number of Successful E-RAB(QCI3) Re-Establishment Outgoing

54

C373546261

Number of Successful E-RAB(QCI4) Re-Establishment Outgoing

55

C373546262

Number of Successful E-RAB(QCI5) Re-Establishment Outgoing

56

C373546263

Number of Successful E-RAB(QCI6) Re-Establishment Outgoing

57

C373546264

Number of Successful E-RAB(QCI7) Re-Establishment Outgoing

58

C373546265

Number of Successful E-RAB(QCI8) Re-Establishment Outgoing

59

C373546266

Number of Successful E-RAB(QCI9) Re-Establishment Outgoing

60

C373546267

Number of Successful E-RAB Re-Establishment Outgoing

2-227
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.3 Counter Description


2.5.3.1 C373210452 Number of Successful E-RAB(QCI1) HO Incoming
Definition

The counter is used to count the number of QCI1 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI1 E-RAB.

Explanation

Each QCI1 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI1 E-RAB.

2.5.3.2 C373210453 Number of Successful E-RAB(QCI2) HO Incoming


Definition

The counter is used to count the number of QCI2 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI2 E-RAB.

Explanation

Each QCI2 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI2 E-RAB.

2-228
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.5.3.3 C373210454 Number of Successful E-RAB(QCI3) HO Incoming


Definition

The counter is used to count the number of QCI3 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI3 E-RAB.

Explanation

Each QCI3 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI3 E-RAB.

2.5.3.4 C373210455 Number of Successful E-RAB(QCI4) HO Incoming


Definition

The counter is used to count the number of QCI4 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI4 E-RAB.

Explanation

Each QCI4 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI4 E-RAB.

2-229
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.3.5 C373210456 Number of Successful E-RAB(QCI5) HO Incoming


Definition

The counter is used to count the number of QCI5 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI5 E-RAB.

Explanation

Each QCI5 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI5 E-RAB.

2.5.3.6 C373210457 Number of Successful E-RAB(QCI6) HO Incoming


Definition

The counter is used to count the number of QCI6 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI6 E-RAB.

Explanation

Each QCI6 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI6 E-RAB.

2-230
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.5.3.7 C373210458 Number of Successful E-RAB(QCI7) HO Incoming


Definition

The counter is used to count the number of QCI7 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI7 E-RAB.

Explanation

Each QCI7 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI7 E-RAB.

2.5.3.8 C373210459 Number of Successful E-RAB(QCI8) HO Incoming


Definition

The counter is used to count the number of QCI8 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI8 E-RAB.

Explanation

Each QCI8 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI8 E-RAB.

2-231
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.3.9 C373210460 Number of Successful E-RAB(QCI9) HO Incoming


Definition

The counter is used to count the number of QCI9 E-RABs successful


incoming handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete and the UE has QCI9 E-RAB.

Explanation

Each QCI9 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the target
eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete and the UE has QCI9 E-RAB.

2.5.3.10 C373210461 Number of Successful E-RAB HO Incoming


Definition

The counter is used to count the number of E-RABs successful incoming


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverNotify message to the MME
or sends the UeContextRelease message to the source eNodeB indicating
handover complete.

Explanation

Each E-RAB for successful handover incoming is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB when the target


eNodeB sends the HandoverNotify message to the MME or sends the
UeContextRelease message to the source eNodeB indicating handover
complete.

2.5.3.11 C373210462 Number of Successful E-RAB(QCI1) HO Outgoing


Definition

The counter is used to count the number of QCI1 E-RABs successful


outgoing handover.
2-232

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI1
E-RAB.

Explanation

Each QCI1 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI1 E-RAB.

2.5.3.12 C373210463 Number of Successful E-RAB(QCI2) HO Outgoing


Definition

The counter is used to count the number of QCI2 E-RABs successful


outgoing handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI2
E-RAB.

Explanation

Each QCI2 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI2 E-RAB.

2.5.3.13 C373210464 Number of Successful E-RAB(QCI3) HO Outgoing


Definition

The counter is used to count the number of QCI3 E-RABs successful


outgoing handover.
2-233

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI3
E-RAB.

Explanation

Each QCI3 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI3 E-RAB.

2.5.3.14 C373210465 Number of Successful E-RAB(QCI4) HO Outgoing


Definition

The counter is used to count the number of QCI4 E-RABs successful


outgoing handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI4
E-RAB.

Explanation

Each QCI4 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI4 E-RAB.

2.5.3.15 C373210466 Number of Successful E-RAB(QCI5) HO Outgoing


Definition

The counter is used to count the number of QCI5 E-RABs successful


outgoing handover.
2-234

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI5
E-RAB.

Explanation

Each QCI5 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI5 E-RAB.

2.5.3.16 C373210467 Number of Successful E-RAB(QCI6) HO Outgoing


Definition

The counter is used to count the number of QCI6 E-RABs successful


outgoing handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI6
E-RAB.

Explanation

Each QCI6 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI6 E-RAB.

2.5.3.17 C373210468 Number of Successful E-RAB(QCI7) HO Outgoing


Definition

The counter is used to count the number of QCI7 E-RABs successful


outgoing handover.
2-235

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI7
E-RAB.

Explanation

Each QCI7 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI7 E-RAB.

2.5.3.18 C373210469 Number of Successful E-RAB(QCI8) HO Outgoing


Definition

The counter is used to count the number of QCI8 E-RABs successful


outgoing handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI8
E-RAB.

Explanation

Each QCI8 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI8 E-RAB.

2.5.3.19 C373210470 Number of Successful E-RAB(QCI9) HO Outgoing


Definition

The counter is used to count the number of QCI9 E-RABs successful


outgoing handover.
2-236

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete and the UE has QCI9
E-RAB.

Explanation

Each QCI9 E-RAB for successful handover outgoing is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete and the UE has QCI9 E-RAB.

2.5.3.20 C373210471 Number of Successful E-RAB HO Outgoing


Definition

The counter is used to count the number of E-RABs successful outgoing


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB indicating handover complete.

Explanation

Each E-RAB for successful handover outgoing is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the source
eNodeB receives the UEContextReleaseCommand message from the
MME or receives the UEContextRelease message from the target eNodeB
indicating handover complete.

2.5.3.21 C373210472 Number of E-RAB(QCI1) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI1 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-237

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI1 E-RAB.

Explanation

Each QCI1 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI1
E-RAB.

2.5.3.22 C373210473 Number of E-RAB(QCI2) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI2 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI2 E-RAB.

Explanation

Each QCI2 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI2
E-RAB.

2.5.3.23 C373210474 Number of E-RAB(QCI3) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI3 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
2-238

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI3 E-RAB.

Explanation

Each QCI3 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI3
E-RAB.

2.5.3.24 C373210475 Number of E-RAB(QCI4) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI4 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI4 E-RAB.

Explanation

Each QCI4 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI4
E-RAB.

2.5.3.25 C373210476 Number of E-RAB(QCI5) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI5 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-239
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI5 E-RAB.

Explanation

Each QCI5 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI5
E-RAB.

2.5.3.26 C373210477 Number of E-RAB(QCI6) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI6 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI6 E-RAB.

Explanation

Each QCI6 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI6
E-RAB.

2.5.3.27 C373210478 Number of E-RAB(QCI7) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI7 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-240
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI7 E-RAB.

Explanation

Each QCI7 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI7
E-RAB.

2.5.3.28 C373210479 Number of E-RAB(QCI8) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI8 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI8 E-RAB.

Explanation

Each QCI8 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI8
E-RAB.

2.5.3.29 C373210480 Number of E-RAB(QCI9) HO Incoming Admission Request


Definition

The counter is used to count the number of QCI9 E-RABs attempted


handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

2-241
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB and in which IE E-RABs To Be Setup List
includes QCI9 E-RAB.

Explanation

Each QCI9 E-RAB for attempted handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB and in which IE E-RABs To Be Setup List includes QCI9
E-RAB.

2.5.3.30 C373210481 Number of E-RAB HO Incoming Admission Request


Definition

The counter is used to count the number of E-RABs attempted handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB.

Explanation

Each E-RAB for attempted handover incoming is added to the counter.

Updated

The counter is incremented by 1 for every E-RAB When the target eNodeB
receives HANDOVER REQUEST message from the MME or source
eNodeB.

2.5.3.31 C373210482 Number of E-RAB(QCI1) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI1 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI1 E-RAB admission failure.

Explanation

Each QCI1 E-RAB for handover admission failures is added to the counter.

2-242
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI1 E-RAB admission failure.

2.5.3.32 C373210483 Number of E-RAB(QCI2) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI2 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI2 E-RAB admission failure.

Explanation

Each QCI2 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI2 E-RAB admission failure.

2.5.3.33 C373210484 Number of E-RAB(QCI3) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI3 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI3 E-RAB admission failure.

Explanation

Each QCI3 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI3 E-RAB admission failure.

2-243
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.3.34 C373210485 Number of E-RAB(QCI4) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI4 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI4 E-RAB admission failure.

Explanation

Each QCI4 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI4 E-RAB admission failure.

2.5.3.35 C373210486 Number of E-RAB(QCI5) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI5 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI5 E-RAB admission failure.

Explanation

Each QCI5 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI5 E-RAB admission failure.

2.5.3.36 C373210487 Number of E-RAB(QCI6) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI6 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

2-244
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI6 E-RAB admission failure.

Explanation

Each QCI6 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI6 E-RAB admission failure.

2.5.3.37 C373210488 Number of E-RAB(QCI7) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI7 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI7 E-RAB admission failure.

Explanation
Updated

Each QCI7 E-RAB for handover admission failures is added to the counter.
The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI7 E-RAB admission failure.

2.5.3.38 C373210489 Number of E-RAB(QCI8) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI8 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI8 E-RAB admission failure.

Explanation

Each QCI8 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI8 E-RAB admission failure.
2-245

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.3.39 C373210490 Number of E-RAB(QCI9) HO Incoming Admission Fail


Definition

The counter is used to count the number of QCI9 E-RABs handover


failures for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs QCI9 E-RAB admission failure.

Explanation

Each QCI9 E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs QCI9 E-RAB admission failure.

2.5.3.40 C373210491 Number of HO Incoming Admission Fail


Definition

The counter is used to count the number of E-RABs handover failures


for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the target eNodeB receives HANDOVER REQUEST message from


the MME or source eNodeB then occurs E-RAB admission failure.

Explanation

Each E-RAB for handover admission failures is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB When the target
eNodeB receives HANDOVER REQUEST message from the MME or
source eNodeB then occurs E-RAB admission failure.

2.5.3.41 C373546248 Number of Successful E-RAB(QCI1) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI1 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

2-246
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI1 E-RAB.

Explanation

Each QCI1 E-RAB for successful handover incoming is added to the


counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI1 E-RAB.

2.5.3.42 C373546249 Number of Successful E-RAB(QCI2) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI2 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI2 E-RAB.

Explanation

Each QCI2 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI2 E-RAB.

2.5.3.43 C373546250 Number of Successful E-RAB(QCI3) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI3 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI3 E-RAB.

Explanation

Each QCI3 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.
2-247

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI3 E-RAB.

2.5.3.44 C373546251 Number of Successful E-RAB(QCI4) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI4 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI4 E-RAB.

Explanation

Each QCI4 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI4 E-RAB.

2.5.3.45 C373546252 Number of Successful E-RAB(QCI5) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI5 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI5 E-RAB.

Explanation

Each QCI5 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI5 E-RAB.

2-248
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.5.3.46 C373546253 Number of Successful E-RAB(QCI6) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI6 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI6 E-RAB.

Explanation

Each QCI6 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI6 E-RAB.

2.5.3.47 C373546254 Number of Successful E-RAB(QCI7) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI7 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI7 E-RAB.

Explanation

Each QCI7 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI7 E-RAB.

2.5.3.48 C373546255 Number of Successful E-RAB(QCI8) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI8 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-249

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI8 E-RAB.

Explanation

Each QCI8 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI8 E-RAB.

2.5.3.49 C373546256 Number of Successful E-RAB(QCI9) Re-Establishment Incoming


Definition

The counter is used to count the number of QCI9 E-RABs successful


incoming re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell and the UE has QCI9 E-RAB.

Explanation

Each QCI9 E-RAB for successful incoming re-establishment from other


cell to local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell and the UE has QCI9 E-RAB.

2.5.3.50 C373546257 Number of Successful E-RAB Re-Establishment Incoming


Definition

The counter is used to count the number of E-RABs successful incoming


re-establishment from other cell to local cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell receives the RRC CONNECTION REESTABLISHMENT


COMPLETE from the UE in other cell.

2-250
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

Each E-RAB for successful incoming re-establishment from other cell to


local cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
receives the RRC CONNECTION REESTABLISHMENT COMPLETE from
the UE in other cell.

2.5.3.51 C373546258 Number of Successful E-RAB(QCI1) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI1 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI1 E-RAB.

Explanation

Each QCI1 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI1 E-RAB.

2.5.3.52 C373546259 Number of Successful E-RAB(QCI2) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI2 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI2 E-RAB.

Explanation

Each QCI2 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI2 E-RAB.

2-251
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.5.3.53 C373546260 Number of Successful E-RAB(QCI3) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI3 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI3 E-RAB.

Explanation

Each QCI3 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI3 E-RAB.

2.5.3.54 C373546261 Number of Successful E-RAB(QCI4) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI4 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI4 E-RAB.

Explanation

Each QCI4 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI4 E-RAB.

2.5.3.55 C373546262 Number of Successful E-RAB(QCI5) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI5 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-252

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI5 E-RAB.

Explanation

Each QCI5 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI5 E-RAB.

2.5.3.56 C373546263 Number of Successful E-RAB(QCI6) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI6 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI6 E-RAB.

Explanation

Each QCI6 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI6 E-RAB.

2.5.3.57 C373546264 Number of Successful E-RAB(QCI7) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI7 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI7 E-RAB.

2-253
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Each QCI7 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI7 E-RAB.

2.5.3.58 C373546265 Number of Successful E-RAB(QCI8) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI8 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI8 E-RAB.

Explanation

Each QCI8 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI8 E-RAB.

2.5.3.59 C373546266 Number of Successful E-RAB(QCI9) Re-Establishment Outgoing


Definition

The counter is used to count the number of QCI9 E-RABs successful


outgoing re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell and the UE has QCI9 E-RAB.

Explanation

Each QCI9 E-RAB for successful outgoing re-establishment from local cell
to other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell and the UE has QCI9 E-RAB.

2-254
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.5.3.60 C373546267 Number of Successful E-RAB Re-Establishment Outgoing


Definition

The counter is used to count the number of E-RABs successful outgoing


re-establishment from local cell to other cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the local cell trigger the UE release for RRC CONNECTION
REESTABLISHMENT to other cell.

Explanation

Each E-RAB for successful outgoing re-establishment from local cell to


other cell is added to the counter.

Updated

The counter is incremented by 1 for every this E-RAB when the local cell
trigger the UE release for RRC CONNECTION REESTABLISHMENT to
other cell.

2.6 E-RAB Activity


2.6.1 Flow Charts and Sampling Points
The E-RABs is said to be activity if any E-RAB data on any Data Radio Bearer (UL or DL)
has been transferred during the last 100 ms.

2.6.2 Counter List


NO.

Counter

Counter Name

Number
1

C373505300

Number of Abnormal Release Active ERAB(QCI=1)

C373505301

Number of Abnormal Release Active ERAB(QCI=2)

C373505302

Number of Abnormal Release Active ERAB(QCI=3)

C373505303

Number of Abnormal Release Active ERAB(QCI=4)

C373505304

Number of Abnormal Release Active ERAB(QCI=5)

C373505305

Number of Abnormal Release Active ERAB(QCI=6)

C373505306

Number of Abnormal Release Active ERAB(QCI=7)

C373505307

Number of Abnormal Release Active ERAB(QCI=8)

C373505308

Number of Abnormal Release Active ERAB(QCI=9)

10

C373505402

UE InSession Active Time

2-255
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
11

C373505403

QCI1 E-RABs InSession Active Time

12

C373505404

QCI2 E-RABs InSession Active Time

13

C373505405

QCI3 E-RABs InSession Active Time

14

C373505406

QCI4 E-RABs InSession Active Time

15

C373505407

QCI5 E-RABs InSession Active Time

16

C373505408

QCI6 E-RABs InSession Active Time

17

C373505409

QCI7 E-RABs InSession Active Time

18

C373505410

QCI8 E-RABs InSession Active Time

19

C373505411

QCI9 E-RABs InSession Active Time

20

C373505498

E-RABs InSession Active Time

2.6.3 Counter Description


2.6.3.1 C373505300 Number of Abnormal Release Active ERAB(QCI=1)
Definition

The counter is used to count the number of released QCI1 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI1 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI1 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI1 E-RAB with data in a buffer


that was abnormally released.

2.6.3.2 C373505301 Number of Abnormal Release Active ERAB(QCI=2)


Definition

The counter is used to count the number of released QCI2 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative
2-256

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI2 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI2 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI2 E-RAB with data in a buffer


that was abnormally released.

2.6.3.3 C373505302 Number of Abnormal Release Active ERAB(QCI=3)


Definition

The counter is used to count the number of released QCI3 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI3 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI3 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI3 E-RAB with data in a buffer


that was abnormally released.

2.6.3.4 C373505303 Number of Abnormal Release Active ERAB(QCI=4)


Definition

The counter is used to count the number of released QCI4 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI4 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI4 E-RAB is added to the counter.

2-257
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when a QCI4 E-RAB with data in a buffer


that was abnormally released.

2.6.3.5 C373505304 Number of Abnormal Release Active ERAB(QCI=5)


Definition

The counter is used to count the number of released QCI5 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI5 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI5 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI5 E-RAB with data in a buffer


that was abnormally released.

2.6.3.6 C373505305 Number of Abnormal Release Active ERAB(QCI=6)


Definition

The counter is used to count the number of released QCI6 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI6 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI6 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI6 E-RAB with data in a buffer


that was abnormally released.

2.6.3.7 C373505306 Number of Abnormal Release Active ERAB(QCI=7)


Definition

The counter is used to count the number of released QCI7 E-RABs that
were active at the time of release.
2-258

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI7 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI7 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI7 E-RAB with data in a buffer


that was abnormally released.

2.6.3.8 C373505307 Number of Abnormal Release Active ERAB(QCI=8)


Definition

The counter is used to count the number of released QCI8 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI8 E-RAB with data in a buffer that was abnormally released.

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI8 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI8 E-RAB with data in a buffer


that was abnormally released.

2.6.3.9 C373505308 Number of Abnormal Release Active ERAB(QCI=9)


Definition

The counter is used to count the number of released QCI9 E-RABs that
were active at the time of release.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a QCI9 E-RAB with data in a buffer that was abnormally released.

2-259
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The abnormally released E-RABs that were active at the time of release.
i.e.when there was user data in the queue in any of the directions. Each
QCI9 E-RAB is added to the counter.

Updated

The counter is incremented by 1 when a QCI9 E-RAB with data in a buffer


that was abnormally released.

2.6.3.10 C373505402 UE InSession Active Time


Definition

The counter is used to count the aggregated active session time for UEs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When UE data on any Data Radio Bearer (UL or DL) has been transferred
during each sampling point.

Explanation

The counter is used to count number of session seconds aggregated for


E-RABs with a UE. The E-RABs for a UE is said to be "in session" if any
E-RAB data on any Data Radio Bearer (UL or DL) has been transferred
during the last 100 ms for that QCI.

Updated

The counter is incremented by 1 when UE data on any Data Radio Bearer


(UL or DL) has been transferred at sampling point.

2.6.3.11 C373505403 QCI1 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI1
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI1 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI1.

Updated

The counter is incremented by 1 when QCI1 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.
2-260

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.6.3.12 C373505404 QCI2 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI2
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI2 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI2.

Updated

The counter is incremented by 1 when QCI2 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.13 C373505405 QCI3 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI3
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI3 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI3.

Updated

The counter is incremented by 1 when QCI3 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.14 C373505406 QCI4 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI4
E-RABs.

2-261
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI4 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI4.

Updated

The counter is incremented by 1 when QCI4 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.15 C373505407 QCI5 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI5
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI5 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI5.

Updated

The counter is incremented by 1 when QCI5 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.16 C373505408 QCI6 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI6
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit
2-262

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When QCI6 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI6.

Updated

The counter is incremented by 1 when QCI6 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.17 C373505409 QCI7 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI7
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI7 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI7.

Updated

The counter is incremented by 1 when QCI7 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.18 C373505410 QCI8 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI8
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI8 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

2-263
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI8.

Updated

The counter is incremented by 1 when QCI8 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.19 C373505411 QCI9 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for QCI9
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When QCI9 E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms for QCI9.

Updated

The counter is incremented by 1 when QCI9 data on any Data Radio


Bearer (UL or DL) has been transferred at sampling point.

2.6.3.20 C373505498 E-RABs InSession Active Time


Definition

The counter is used to count the aggregated active session time for
E-RABs.

Sampling Interval

100 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred at sampling point.

Explanation

The counter is used to count number of session seconds aggregated


for E-RABs with a certain QCI. The E-RABs for a UE is said to be "in
session" if any E-RAB data on any Data Radio Bearer (UL or DL) has been
transferred during the last 100 ms.
2-264

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is incremented by 1 when UE data on any Data Radio Bearer


(UL or DL) has been transferred at sampling point.

2.7 E-RAB Number


2.7.1 Flow Charts and Sampling Points
No chart.

2.7.2 Counter List


NO.

Counter

Counter Name

Number
1

C373240800

Average ERAB Number (QCI=1)

C373240801

Average ERAB Number (QCI=2)

C373240802

Average ERAB Number (QCI=3)

C373240803

Average ERAB Number (QCI=4)

C373240804

Average ERAB Number (QCI=5)

C373240805

Average ERAB Number (QCI=6)

C373240806

Average ERAB Number (QCI=7)

C373240807

Average ERAB Number (QCI=8)

C373240808

Average ERAB Number (QCI=9)

10

C373240809

Online ERAB Number (QCI=1)

11

C373240810

Online ERAB Number (QCI=2)

12

C373240811

Online ERAB Number (QCI=3)

13

C373240812

Online ERAB Number (QCI=4)

14

C373240813

Online ERAB Number (QCI=5)

15

C373240814

Online ERAB Number (QCI=6)

16

C373240815

Online ERAB Number (QCI=7)

17

C373240816

Online ERAB Number (QCI=8)

18

C373240817

Online ERAB Number (QCI=9)

19

C373240818

Maximum ERAB Number (QCI=1)

20

C373240819

Maximum ERAB Number (QCI=2)

21

C373240820

Maximum ERAB Number (QCI=3)

22

C373240821

Maximum ERAB Number (QCI=4)

2-265
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
23

C373240822

Maximum ERAB Number (QCI=5)

24

C373240823

Maximum ERAB Number (QCI=6)

25

C373240824

Maximum ERAB Number (QCI=7)

26

C373240825

Maximum ERAB Number (QCI=8)

27

C373240826

Maximum ERAB Number (QCI=9)

28

C373240827

Average ERAB Number

29

C373240828

Online ERAB Number

30

C373240829

Maximum ERAB Number

2.7.3 Counter Description


2.7.3.1 C373240800 Average ERAB Number (QCI=1)
Definition

The counter is used to count the average number of simultaneous QCI1


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI1 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI1 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI1 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI1 E-RAB number


among sampling points.

2.7.3.2 C373240801 Average ERAB Number (QCI=2)


Definition

The counter is used to count the average number of simultaneous QCI2


E-RABs.

Sampling Interval

10 s

Counter Type

Average

2-266
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI2 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI2 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI2 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI2 E-RAB number


among sampling points.

2.7.3.3 C373240802 Average ERAB Number (QCI=3)


Definition

The counter is used to count the average number of simultaneous QCI3


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI3 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI3 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI3 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI3 E-RAB number


among sampling points.

2.7.3.4 C373240803 Average ERAB Number (QCI=4)


Definition

The counter is used to count the average number of simultaneous QCI4


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

2-267
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB has an QCI4 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI4 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI4 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI4 E-RAB number


among sampling points.

2.7.3.5 C373240804 Average ERAB Number (QCI=5)


Definition

The counter is used to count the average number of simultaneous QCI5


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI5 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI5 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI5 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI5 E-RAB number


among sampling points.

2.7.3.6 C373240805 Average ERAB Number (QCI=6)


Definition

The counter is used to count the average number of simultaneous QCI6


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI6 E-RAB successfully established or


released.

2-268
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When the eNodeB has an QCI6 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI6 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI6 E-RAB number


among sampling points.

2.7.3.7 C373240806 Average ERAB Number (QCI=7)


Definition

The counter is used to count the average number of simultaneous QCI7


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI7 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI7 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI7 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI7 E-RAB number


among sampling points.

2.7.3.8 C373240807 Average ERAB Number (QCI=8)


Definition

The counter is used to count the average number of simultaneous QCI8


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI8 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI8 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI8 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.
2-269

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by the arithmetic mean of QCI8 E-RAB number


among sampling points.

2.7.3.9 C373240808 Average ERAB Number (QCI=9)


Definition

The counter is used to count the average number of simultaneous QCI9


E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI9 E-RAB successfully established or


released.

Explanation

When the eNodeB has an QCI9 E-RAB successfully established, the


counter of E-RAB number is increased by 1. When the eNodeB has an
QCI9 E-RAB successfully released by MME or eNodeB, the counter of
E-RAB number is decreased by 1.

Updated

The counter is updated by the arithmetic mean of QCI9 E-RAB number


among sampling points.

2.7.3.10 C373240809 Online ERAB Number (QCI=1)


Definition

The counter is used to count the online number of simultaneous QCI1


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI1 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI1 E-RAB number at sampling


points.

2-270
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.7.3.11 C373240810 Online ERAB Number (QCI=2)


Definition

The counter is used to count the online number of simultaneous QCI2


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI2 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI2 E-RAB number at sampling


points.

2.7.3.12 C373240811 Online ERAB Number (QCI=3)


Definition

The counter is used to count the online number of simultaneous QCI3


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI3 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter ofE-RAB number is
decreased by 1.

Updated

The counter is updated by the current QCI3 E-RAB number at sampling


points.

2.7.3.13 C373240812 Online ERAB Number (QCI=4)


Definition

The counter is used to count the online number of simultaneous QCI4


E-RABs.

2-271
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI4 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI4 E-RAB number at sampling


points.

2.7.3.14 C373240813 Online ERAB Number (QCI=5)


Definition

The counter is used to count the online number of simultaneous QCI5


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI5 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI5 E-RAB number at sampling


points.

2.7.3.15 C373240814 Online ERAB Number (QCI=6)


Definition

The counter is used to count the online number of simultaneous QCI6


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit
2-272

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI6 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI6 E-RAB number at sampling


points.

2.7.3.16 C373240815 Online ERAB Number (QCI=7)


Definition

The counter is used to count the online number of simultaneous QCI7


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI7 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI7 E-RAB number at sampling


points.

2.7.3.17 C373240816 Online ERAB Number (QCI=8)


Definition

The counter is used to count the online number of simultaneous QCI8


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI8 E-RAB successfully established or


released.

2-273
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI8 E-RAB number at sampling


points.

2.7.3.18 C373240817 Online ERAB Number (QCI=9)


Definition

The counter is used to count the online number of simultaneous QCI9


E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI9 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current QCI9 E-RAB number at sampling


points.

2.7.3.19 C373240818 Maximum ERAB Number (QCI=1)


Definition

The counter is used to count the maximum number of simultaneous QCI1


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI1 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.
2-274

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Updated

The counter is replaced with the current value when the QCI1 E-RAB
number in sampling point is larger than the counter.

2.7.3.20 C373240819 Maximum ERAB Number (QCI=2)


Definition

The counter is used to count the maximum number of simultaneous QCI2


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI2 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI2 E-RAB
number in sampling point is larger than the counter.

2.7.3.21 C373240820 Maximum ERAB Number (QCI=3)


Definition

The counter is used to count the maximum number of simultaneous QCI3


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI3 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI3 E-RAB
number in sampling point is larger than the counter.

2-275
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.7.3.22 C373240821 Maximum ERAB Number (QCI=4)


Definition

The counter is used to count the maximum number of simultaneous QCI4


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI4 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI4 E-RAB
number in sampling point is larger than the counter.

2.7.3.23 C373240822 Maximum ERAB Number (QCI=5)


Definition

The counter is used to count the maximum number of simultaneous QCI5


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI5 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI5 E-RAB
number in sampling point is larger than the counter.

2.7.3.24 C373240823 Maximum ERAB Number (QCI=6)


Definition

The counter is used to count the maximum number of simultaneous QCI6


E-RABs.

2-276
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI6 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI6 E-RAB
number in sampling point is larger than the counter.

2.7.3.25 C373240824 Maximum ERAB Number (QCI=7)


Definition

The counter is used to count the maximum number of simultaneous QCI7


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI7 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI7 E-RAB
number in sampling point is larger than the counter.

2.7.3.26 C373240825 Maximum ERAB Number (QCI=8)


Definition

The counter is used to count the maximum number of simultaneous QCI8


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit
2-277

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI8 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI8 E-RAB
number in sampling point is larger than the counter.

2.7.3.27 C373240826 Maximum ERAB Number (QCI=9)


Definition

The counter is used to count the maximum number of simultaneous QCI9


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an QCI9 E-RAB successfully established or


released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the QCI9 E-RAB
number in sampling point is larger than the counter.

2.7.3.28 C373240827 Average ERAB Number


Definition

The counter is used to count the mean number of simultaneous E-RABs.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an E-RAB successfully established or released.

2-278
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by arithmetic mean of the E-RAB number among


sampling points.

2.7.3.29 C373240828 Online ERAB Number


Definition

The counter is used to count the online number of simultaneous E-RABs.

Sampling Interval

10 s

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an E-RAB successfully established or released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is updated by the current E-RAB number at sampling points.

2.7.3.30 C373240829 Maximum ERAB Number


Definition

The counter is used to count the maximum number of simultaneous


E-RABs.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB has an E-RAB successfully established or released.

Explanation

When the eNodeB has an E-RAB successfully established, the counter


of E-RAB number is increased by 1. When the eNodeB has an E-RAB
successfully released by MME or eNodeB, the counter of E-RAB number
is decreased by 1.

Updated

The counter is replaced with the current value when the E-RAB number at
sampling point is larger than the counter.

2-279
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.8 E-RAB Setup Time


2.8.1 Flow Charts and Sampling Points
Figure 2-5 E-RAB Setup Time(1)

l
l

Sampling Point 1: The eNodeB records the start time when it receives the
InitialContextSetupRequest message from MME.
Sampling Point 2: The eNodeB records the end time when it sends the InitialContextSetupResponse message to MME.

Figure 2-6 E-RAB Setup Time(2)

Sampling Point 3: The eNodeB records the start time when it receives the
ERABSetupRequest message from MME.
2-280

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point 4: The eNodeB records the end time when it sends the
ERABSetupResponse message to MME.

2.8.2 Counter List


NO.

Counter

Counter Name

Number
1

C373505327

Mean Time of QCI1 SAE Bearer Setup

C373505328

Mean Time of QCI2 SAE Bearer Setup

C373505329

Mean Time of QCI3 SAE Bearer Setup

C373505330

Mean Time of QCI4 SAE Bearer Setup

C373505331

Mean Time of QCI5 SAE Bearer Setup

C373505332

Mean Time of QCI6 SAE Bearer Setup

C373505333

Mean Time of QCI7 SAE Bearer Setup

C373505334

Mean Time of QCI8 SAE Bearer Setup

C373505335

Mean Time of QCI9 SAE Bearer Setup

10

C373505336

Maximum Time of QCI1 SAE Bearer Setup

11

C373505337

Maximum Time of QCI2 SAE Bearer Setup

12

C373505338

Maximum Time of QCI3 SAE Bearer Setup

13

C373505339

Maximum Time of QCI4 SAE Bearer Setup

14

C373505340

Maximum Time of QCI5 SAE Bearer Setup

15

C373505341

Maximum Time of QCI6 SAE Bearer Setup

16

C373505342

Maximum Time of QCI7 SAE Bearer Setup

17

C373505343

Maximum Time of QCI8 SAE Bearer Setup

18

C373505344

Maximum Time of QCI9 SAE Bearer Setup

2.8.3 Counter Description


2.8.3.1 C373505327 Mean Time of QCI1 SAE Bearer Setup
Definition

The counter is used to count the mean time it takes to establish an QCI1
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell
2-281

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI1
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI1 E-RAB setup time
among sampling points.

2.8.3.2 C373505328 Mean Time of QCI2 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI2
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI2
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI2 E-RAB setup time
among sampling points.

2-282
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.8.3.3 C373505329 Mean Time of QCI3 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI3
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI3
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI3 E-RAB setup time
among sampling points.

2.8.3.4 C373505330 Mean Time of QCI4 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI4
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

2-283
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI4
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI4 E-RAB setup time
among sampling points.

2.8.3.5 C373505331 Mean Time of QCI5 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI5
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI5
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI5 E-RAB setup time
among sampling points.

2.8.3.6 C373505332 Mean Time of QCI6 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI6
E-RAB.

Sampling Interval

10 s

2-284
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI6
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI6 E-RAB setup time
among sampling points.

2.8.3.7 C373505333 Mean Time of QCI7 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI7
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI7
E-RABs in the granularity period to give the arithmetic mean.
2-285

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by the arithmetic mean of QCI7 E-RAB setup time
among sampling points.

2.8.3.8 C373505334 Mean Time of QCI8 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI8
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI8
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI8 E-RAB setup time
among sampling points.

2.8.3.9 C373505335 Mean Time of QCI9 SAE Bearer Setup


Definition

The counter is used to count the mean time it takes to establish an QCI9
E-RAB.

Sampling Interval

10 s

Counter Type

Average

Unit

ms

Measurement Object

Cell

2-286
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. The end value of this
time will then be divided by the number of successfully established QCI9
E-RABs in the granularity period to give the arithmetic mean.

Updated

The counter is updated by the arithmetic mean of QCI9 E-RAB setup time
among sampling points.

2.8.3.10 C373505336 Maximum Time of QCI1 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI1 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI1 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI1 ERAB setup
time at sampling point is larger than the counter.

2-287
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

2.8.3.11 C373505337 Maximum Time of QCI2 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI2 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI2 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI2 ERAB setup
time at sampling point is larger than the counter.

2.8.3.12 C373505338 Maximum Time of QCI3 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI3 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

2-288
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI3 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI3 ERAB setup
time at sampling point is larger than the counter.

2.8.3.13 C373505339 Maximum Time of QCI4 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI4 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI4 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI4 ERAB setup
time at sampling point is larger than the counter.

2.8.3.14 C373505340 Maximum Time of QCI5 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI5 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms
2-289

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI5 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI5 ERAB setup
time at sampling point is larger than the counter.

2.8.3.15 C373505341 Maximum Time of QCI6 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI6 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI6 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI6 ERAB setup
time at sampling point is larger than the counter.

2-290
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 2 Statistics of E-RAB

2.8.3.16 C373505342 Maximum Time of QCI7 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI7 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI7 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI7 ERAB setup
time at sampling point is larger than the counter.

2.8.3.17 C373505343 Maximum Time of QCI8 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI8 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

2-291
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI8 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI8 ERAB setup
time at sampling point is larger than the counter.

2.8.3.18 C373505344 Maximum Time of QCI9 SAE Bearer Setup


Definition

The counter is used to count the maximum time it takes to establish an


QCI9 E-RAB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

ms

Measurement Object

Cell

Sampling Point

When eNodeB send the INITIAL CONTEXT SETUP RESPONSE message


or E-RAB SETUP RESPONSE to MME, eNodeB count the time intervals
from the INITIAL CONTEXT SETUP REQUEST message to the INITIAL
CONTEXT SETUP RESPONSE message,or from the E-RAB SETUP
REQUEST message to the E-RAB SETUP RESPONSE message.
Sampling Point 1, Sampling Point 2, Sampling Point 3, Sampling Point 4

Explanation

The E-RAB setup time is the time intervals for every successfully
established E-RAB between the receipt of an E-RAB SETUP REQUEST
or INITIAL CONTEXT SETUP REQUEST message and the transmission
of the corresponding E-RAB SETUP RESPONSE or INITIAL CONTEXT
SETUP RESPONSE message by the eNodeB. the counter is the largest
about QCI9 E-RAB in the granularity period.

Updated

The counter is replaced with the current value when QCI9 ERAB setup
time at sampling point is larger than the counter.

2-292
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3

Statistics of UE Context
Table of Contents
UE Context Setup ......................................................................................................3-2
UE Context Modification .............................................................................................3-8
UE Context Release.................................................................................................3-11
UE Context for CSFB ...............................................................................................3-19
Security Mode ..........................................................................................................3-22

3-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

3.1 UE Context Setup


3.1.1 Flow Charts and Sampling Points
Figure 3-1 UE Context Setup

l
l
l
l

Sampling Point 1: The EUTRAN receives the INITIAL CONTEXT SETUP REQUEST
message from the MME.
Sampling Point 2:
The EUTRAN sends the RRC CONNECTION
RECONFIGURATION message to the UE.
Sampling Point 3:
The EUTRAN receives the RRC CONNECTION
RECONFIGURATION COMPLETE message from the UE.
Sampling Point 4: The EUTRAN sends the INITIAL CONTEXT SETUP RESPONSE
message to the MME, indicating that the E-RAB Establishment has been set up
successfully.
Sampling
Point
5:
The
EUTRAN
does
not
receive
the
RRCConnectionReconfigurationComplete message from the UE, and the timer
3-2

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

l
l
l

expires. Then EUTRAN sends the INITIAL CONTEXT SETUP FAILURE message
to the MME.
Sampling Point 6: The EUTRAN sends the INITIAL CONTEXT SETUP FAILURE
message to the MME because of not UE context.
Sampling Point 7: The EUTRAN sends the INITIAL CONTEXT SETUP FAILURE
message to the MME because of AS failure.
Sampling Point 8:
The EUTRAN receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE.

3.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373220600

Number of Successful Context Setup

C373220601

Number of Context Setup Failure due to Active Failure in Security Mode

C373220602

Number of Context Setup Failure due to Admission Control Failure

C373220603

Number of Context Setup Failure due to RRC ReConf Failure

C373220604

Number of Context Setup Failure due to UE Reestablish RRC Connection

C373220605

Number of Context Setup Failure due to Context Setup Request Msg Error

C373220606

Number of Context Setup Failure due to Other Cause

C373220623

Number of Context Setup Failure due to Message not Compatible with


eNodeb State

C373220636

Number of Attempted Context Setup

3.1.3 Counter Description


3.1.3.1 C373220600 Number of Successful Context Setup
Definition

The counter is used to count the number of UE Context successful


established.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the INITIAL CONTEXT SETUP RESPONSE


message to the MME.
Sampling Point 4

3-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The eNodeB receives the InitialContextSetupRequest message from the


MME and replies the INITIAL CONTEXT SETUP RESPONSE message
after successful admission, RRC connection reconfiguration, UE ability
and security mode procedure.

Updated

The counter is incremented by 1 when the eNodeB sends the INITIAL


CONTEXT SETUP RESPONSE message to the MME.

3.1.3.2 C373220601 Number of Context Setup Failure due to Active Failure in Security
Mode
Definition

The counter is used to count the number of UE Context failed to setup for
security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB send the InitialContextSetupfailure to the MME due to


security mode failures.
Sampling Point 7

Explanation

The eNodeB receives the InitialContextSetupRequest message from the


MME and replies the INITIAL CONTEXT SETUP failure message after
security mode procedure failure.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextSetupfailure message to the MME due to security mode
failures.

3.1.3.3 C373220602 Number of Context Setup Failure due to Admission Control Failure
Definition

The counter is used to count the number of UE Context failed to setup


for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB send the InitialContextSetupfailure message to the


MME due to admission failures.
Sampling Point 6

3-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Explanation

The eNodeB receives the InitialContextSetupRequest message from the


MME and replies the INITIAL CONTEXT SETUP failure message after
admission procedure failure.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextSetupfailure message to the MME due to admission failures.

3.1.3.4 C373220603 Number of Context Setup Failure due to RRC ReConf Failure
Definition

The counter is used to count the number of UE Context failed to setup


for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB send the InitialContextSetupfailure message to the


MME due to RRC reconfiguration complete timeout.
Sampling Point 6

Explanation

The eNodeB receives the InitialContextSetupRequest message from the


MME and replies the INITIAL CONTEXT SETUP failure message after
RRC connection reconfiguration procedure failure for timeout.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextSetupfailure message to the MME due to RRC reconfiguration
complete timeout.

3.1.3.5 C373220604 Number of Context Setup Failure due to UE Reestablish RRC


Connection
Definition

The counter is used to count the number of UE Context failed to setup


for re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB send the InitialContextSetupfailure message to the


MME due to receiving the RRC connection re-establishment message.
Sampling Point 8

3-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The eNodeB receives the InitialContextSetupRequest message from


the MME and replies INITIAL CONTEXT SETUP failure message after
receiving RRC connection reestablishment message.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextSetupfailure message to the MME due to RRC
re-establishment.

3.1.3.6 C373220605 Number of Context Setup Failure due to Context Setup Request
Msg Error
Definition

The counter is used to count the number of UE Context failed to setup


for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB send the InitialContextSetupfailure message to the


MME due to message parameter error.
Sampling Point 6

Explanation

The eNodeB receives the InitialContextSetupRequest message from


the MME and replies INITIAL CONTEXT SETUP failure message after
detecting parameter failure.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextSetupfailure message to the MME due to message parameter
error.

3.1.3.7 C373220606 Number of Context Setup Failure due to Other Cause


Definition

The counter is used to count the number of UE Context failed to setup


for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB send the InitialContextSetupfailure to the MME due


to other reason.
Sampling Point 6

3-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Explanation

The eNodeB receives the InitialContextSetupRequest message from the


MME and replies the INITIAL CONTEXT SETUP failure message for some
eNodeB internal errors.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextSetupfailure message to the MME due to other reason.

3.1.3.8 C373220623 Number of Context Setup Failure due to Message not Compatible
with eNodeb State
Definition

The counter is used to count the number of UE Context failed to setup for
message not compatible with receiver state.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the INITIAL CONTEXT SETUP failure message
due to message not compatible with receiver state.
Sampling Point 6

Explanation

The eNodeB's state is not the UE context setup when receiving the INITIAL
CONTEXT SETUP REQUEST message from the MME.Then the eNodeB
reply the INITIAL CONTEXT SETUP failure message to the MME.

Updated

The counter is incremented by 1 when the eNodeB sends the INITIAL


CONTEXT SETUP failure message due to message not compatible with
receiver state.

3.1.3.9 C373220636 Number of Attempted Context Setup


Definition

The counter is used to count the number of UE Context attempted to setup.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the InitialContextSetupRequest message


from the MME.
Sampling Point 1

Explanation

On receipt by the eNodeB of an InitialContextSetupRequest message from


MME, each InitialContextSetupRequest message received is added to
the counter.
3-7

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB receives the


InitialContextSetupRequest message from the MME.

3.2 UE Context Modification


3.2.1 Flow Charts and Sampling Points
Figure 3-2 UE Context Modification

Sampling Point 1: The eNodeB receives the UEContextModificationRequest message


from the MME.
Sampling Point 2: The eNodeB sends the UEContextModificationResponse message to
the MME.
Sampling Point 3: The eNodeB sends the UEContextModificationFailure message to the
MME.

3.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373220607

Number of Successful Context Modify

3-8
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

NO.

Counter

Counter Name

Number
2

C373220608

Number of Context Modify Failure due to ENB Admission Failure

C373220609

Number of Context Modify Failure due to Msg Param Error

C373220610

Number of Context Modify Failure due to Other Cause

C373220632

Number of Context Modify Failure due to Waiting Reconfiguration Complete


timeout

3.2.3 Counter Description


3.2.3.1 C373220607 Number of Successful Context Modify
Definition

The counter is used to count the number of UE Context successfully


modified the QoS parameter.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT MODIFICATION RESPONSE


message to the MME.
Sampling Point 2

Explanation

The eNodeB receives the InitialContextModificationRequest message from


the MME and replies the INITIAL CONTEXT MODIFICATION RESPONSE
message after successful admission, RRC connection reconfiguration
procedure.

Updated

The counter is incremented by 1 when the eNodeB sends the INITIAL


CONTEXT MODIFICATION RESPONSE message to the MME.

3.2.3.2 C373220608 Number of Context Modify Failure due to ENB Admission Failure
Definition

The counter is used to count failed to be modified the QoS parameter


for admission failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

3-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the UE CONTEXT MODIFICATION failure


message to the MME due to admission failures.
Sampling Point 3.

Explanation

The eNodeB receives the InitialContextModificationRequest message from


the MME and replies the INITIAL CONTEXT MODIFICATION FAILURE
message after admission procedure failures.

Updated

The counter is incremented by 1 when the eNodeB sends the


InitialContextModificationfailure message to the MME due to admission
failures.

3.2.3.3 C373220609 Number of Context Modify Failure due to Msg Param Error
Definition

The counter is used to count failed to be modified the QoS parameter


for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT MODIFICATION failure


message to the MME due to message parameter error.
Sampling Point 3.

Explanation

The eNodeB receives the InitialContextModificationRequest message from


the MME and replies the INITIAL CONTEXT MODIFICATION FAILURE
message after detection parameter failures.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextModificationFailure message to the MME due to parameter
error.

3.2.3.4 C373220610 Number of Context Modify Failure due to Other Cause


Definition

The counter is used to count failed to be modified the QoS parameter


for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

3-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Sampling Point

When the eNodeB sends the UE CONTEXT MODIFICATION failure


message to the MME due to other reason.
Sampling Point 3

Explanation

The eNodeB receives the InitialContextModificationRequest message from


the MME and replies the INITIAL CONTEXT MODIFICATION FAILURE
message for some eNodeB internal errors.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextModificationFailure message to the MME due other reason.

3.2.3.5 C373220632 Number of Context Modify Failure due to Waiting Reconfiguration


Complete timeout
Definition

The counter is used to count the number of UE Context failed to be


modified the QoS parameter for timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextModificationFailure message to


the MME due to timeout of waiting for the RRCConnectionReconfiguration
Complete message.
Sampling Point 3

Explanation

After the eNodeB receive the UE CONTEXT MODIFICATION REQUEST,


sends the RRCConnectionReconfiguration message to UE. When the
timer of waiting for the ReconfigurationComplete expires the eNodeb reply
the UE CONTEXT MODIFICATION failures to the MME.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextModificationFailure message to the MME due to timeout of
waiting for the RRCConnectionReconfiguration Complete message.

3.3 UE Context Release


3.3.1 Flow Charts and Sampling Points

3-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 3-3 UE Context Release

l
l
l
l

Sampling Point 1: The EUTRAN sends the UE Context ReleaseRequest message to


the MME.
Sampling Point 2: The EUTRAN receives the UE Context ReleaseCommand message from the MME.
Sampling Point 3: The EUTRAN receives the RESET message from the MME.
Sampling Point 4: The EUTRAN receives the Error Indication message from the MME.

3.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373220611

Number of Context Release by MME due to UE CONTEXT RELEASE


COMMAND

C373220612

Number of Context Release by ENB due to Uu Interface Failure

C373220613

Number of Context Release by ENB due to Handover Failure

C373220614

Number of Context Release by ENB due to Cell Block or Reset


3-12

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

NO.

Counter

Counter Name

Number
5

C373220615

Number of Context Release by ENB due to Inactivity

C373220616

Number of Context Release by ENB due to Other

C373220617

Number of Context Release by MME due to Error Indication or Reestablish


Inter eNB

C373220618

Number of Context Release by ENB due to Redirection

C373220620

Number of Context Release by ENB due to Re-estblishment Fail

10

C373220621

Number of Context Release by ENB due to S1 Link Fail

11

C373220622

Number of Context Release by ENB due to UE Not Online

12

C373220624

Number of Context Release by MME due to Other Reason

13

C373220635

Number of Context Release by ENB due to CCO cause

3.3.3 Counter Description


3.3.3.1 C373220611 Number of Context Release by MME due to UE CONTEXT
RELEASE COMMAND
Definition

The counter is used to count the number of UE CONTEXT Release


initiated by MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand message


from the MME and the Cause in the message is "Normal Relase",
"Detach"," Authentication failure" or" Interaction with other procedure".
Sampling Point 2

Explanation

The eNodeB receives the UEContextReleaseCommand message from the


MME, in which the Cause is "Normal Relase", "Detach"," Authentication
failure" or" Interaction with other procedure". The counter is used to count
the number of UE Context Release initiated by MME due to the above
condition.

Updated

The counter is incremented by 1 when the eNodeB receives


UEContextReleaseCommand message from the MME.

3-13
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

3.3.3.2 C373220612 Number of Context Release by ENB due to Uu Interface Failure


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for Radio Link failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to radio link failures.
Sampling Point 1

Explanation

The eNodeB trigger UE release when timer of RRC reestablishment


complete expires during RRC reestablishment.
The eNodeB trigger UE release when RLC PDU gets maximum
retransmition number.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to radio link failures.

3.3.3.3 C373220613 Number of Context Release by ENB due to Handover Failure


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to handover failures.
Sampling Point 1

Explanation

The eNodeB's timer of waiting for the UEContextReleaseCommand


message expires during handover, eNodeB will trigger UE release. The
cause occurs the source cell.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to handover failures.

3.3.3.4 C373220614 Number of Context Release by ENB due to Cell Block or Reset
Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for cell block or reset.
3-14

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to cell block or reset.
Sampling Point 1

Explanation

The eNodeB receives the Cell Block Command from the OMM for manual
operation.
The eNodeB occurs alarm that trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to cell reset or block.

3.3.3.5 C373220615 Number of Context Release by ENB due to Inactivity


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for handover failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to user inactive.
Sampling Point 1

Explanation

In the condition of opening "USER INACTIVITY" switch,the eNodeB


detects user that have no DTCH data queued on the downlink and the
uplink during configuration intervals. The user is regarded as "inactivity".

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to user inactivity.

3.3.3.6 C373220616 Number of Context Release by ENB due to Other


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
3-15

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to other reason.
Sampling Point 1

Explanation

The eNodeB detects some internal reasons that trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to other reason.

3.3.3.7 C373220617 Number of Context Release by MME due to Error Indication or


Reestablish Inter eNB
Definition

The counter is used to count the number of UE CONTEXT Release


initiated by MME for abnormal reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME.
When the eNodeB receives the UEContextReleaseCommand message
from the MME and the Cause in the message is "Failure in the Radio
Interface Procedure".
Sampling Point 1, Sampling Point 4

Explanation

The counter is used to count the number of UE Context Release initiated


by MME due to the following two conditions.
The eNodeB receives the UEContextReleaseCommand message from
MME, in which the Cause is "Failure in the Radio Interface Procedure",
then release the UE Context. The eNodeB receives the ErrorIndication
message from the MME, then release the UE Context.

Updated

The counter is incremented by 1 when the eNodeB receives the


ErrorIndication message or UEContextReleaseCommand message from
the MME.

3.3.3.8 C373220618 Number of Context Release by ENB due to Redirection


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for redirection.

Sampling Interval

Event triggered

Counter Type

Accumulative

3-16
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to the UE redirection.
Sampling Point 1

Explanation

The eNodeB concludes UE redirection to other cell or eNodeB, then trigger


UE release.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to UE redirection.

3.3.3.9 C373220620 Number of Context Release by ENB due to Re-estblishment Fail


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for re-establishment failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to RRC connection re-establishment failures.
Sampling Point 1

Explanation

The eNodeB will trigger UE release after sending the RRCConnectionReestablishmentReject message to UE.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to RRC connection
re-establishment failures.

3.3.3.10 C373220621 Number of Context Release by ENB due to S1 Link Fail


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for S1 link fault.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

3-17
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to S1 link fault.
Sampling Point 1

Explanation

The counter includes the two following conditions.


The eNodeB detects the fiber fault then trigger UE release.
The eNodeB detects the GTPU path fault then trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to S1 link fault.

3.3.3.11 C373220622 Number of Context Release by ENB due to UE Not Online


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for Radio Connection With UE Lost.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UE CONTEXT RELEASE REQUEST


message to the MME due to Radio Connection With UE Lost.
Sampling Point 1.

Explanation

The eNodeB judge UE's state according to HARQ feedback algorithm. If


the UE's state is concluded as offline, the eNodeB will trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to UE offline.

3.3.3.12 C373220624 Number of Context Release by MME due to Other Reason


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by MME for other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand message


from the MME.
Sampling Point 1

3-18
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Explanation

The eNodeB receives the UEContextReleaseCommand message


from MME, in which the Cause excludes Normal Release, Detach,
Authentication failure, Failure in the Radio Interface Procedure, Successful
Handover and Interaction with other procedure. The counter is used to
count the number of UE Context Release initiated by MME due to the
above condition.

Updated

The counter is incremented by 1 when the eNodeB receives the


UEContextReleaseCommand message from the MME.

3.3.3.13 C373220635 Number of Context Release by ENB due to CCO cause


Definition

The counter is used to count the number of UE CONTEXT Release


initiated by eNodeB for CCO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UEContextReleaseRequest message to


the MME due to CCO.
Sampling Point 1

Explanation

The eNodeB concludes UE CCO to other cell or eNodeB, then trigger


UE release.

Updated

The counter is incremented by 1 when the eNodeB sends the


UEContextReleaseRequest message to the MME due to CCO.

3.4 UE Context for CSFB


3.4.1 Flow Charts and Sampling Points
Refer to:
l
l
l

Figure 3-1 UE Context Setup


Figure 3-2 UE Context Modification
Figure 3-3 UE Context Release

3.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373220653

Number of Attempted Other Initial Context Setup with CSFB


3-19

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
2

C373220654

Number of Successful Other Initial Context Setup with CSFB

C373220655

Number of Other UE Context Release with CSFB

3.4.3 Counter Description


3.4.3.1 C373220653 Number of Attempted Other Initial Context Setup with CSFB
Definition

The counter is used to count the number of UE Context attempted to setup


for CSFB and the RRC establishmentCause neither mt nor mo type.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the InitialContextSetupRequest with CSFB


indication message from the MME and the RRC establishmentCause
neither mt nor mo type.
Figure 3-1 UE Context Setup: Sampling Point 1

Explanation

After the LTE user sends the service request message to MME for neither
mt nor mo type, the MME find the eNodeB not supportting CS service.Then
the MME requires eNodeB to establish the UE Context which indicates CS
service fallback to GERAN/UTRAN. The counter calculates the number
of this UE Context setup attempts.

Updated

The counter is incremented by 1 when the eNodeB receives the


InitialContextSetupRequest with CSFB indication message from the MME
for neither mt nor mo type.

3.4.3.2 C373220654 Number of Successful Other Initial Context Setup with CSFB
Definition

The counter is used to count the number of UE Context successful


established for CSFB and the RRC establishmentCause neither mt nor
mo type.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

3-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Sampling Point

When the eNodeB replys the InitialContextSetupResponse message from


the MME for CSFB and the RRC establishmentCause neither mt nor mo
type.
Figure 3-1 UE Context Setup: Sampling Point 4

Explanation

After the LTE user sends the service request message to MME for neither
mt nor mo type, the MME requires eNodeB to establish the UE Context
which indicates CS service fallback to GERAN/UTRAN. The counter
calculates the number of this UE Context successful setup.

Updated

The counter is incremented by 1 when the eNodeB replys the


InitialContextSetupResponse message from the MME with CSFB for
neither mt nor mo type.

3.4.3.3 C373220655 Number of Other UE Context Release with CSFB


Definition

The counter is used to count the number of UE CONTEXT Release for


CSFB and the RRC establishmentCause neither mt nor mo type.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UEContextReleaseCommand message


from the MME for CSFB and the RRC establishmentCause neither mt
nor mo type.
Figure 3-3 UE Context Release: Sampling Point 2

Explanation

After the LTE user sends the service request message to MME for neither
mt nor mo type, the MME requires eNodeB to establish the UE Context
which indicates CS service fallback to GERAN/UTRAN. The eNodeB
indicates the UE accessing to the target GERAN/UTRAN cell through
the PS HO/CCO/Redirection. The counter calculates the number of this
UE Context release.

Updated

The counter is incremented by 1 when the eNodeB receives the


UEContextReleaseCommand message from the MME with CSFB for
neither mt nor mo type.

3-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

3.5 Security Mode


3.5.1 Flow Charts and Sampling Points
Figure 3-4 Security Mode

l
l
l

Sampling Point 1: The eNodeb sends the SecurityModeCommand message to UE,


indicating the start of security activation procedure.
Sampling Point 2: The eNodeb receives the SecurityModeComplete message from
UE, indicating that the AS Security has been activated successfully.
Sampling Point 3: The eNodeb receives the SecurityModeFailure message from UE,
indicating that the AS Security has been failed to activate.

3.5.2 Counter List


NO.

Counter

Counter Name

Number
1

C373220630

Number of Successful Security Mode

C373220631

Number of Failed Security Mode

3.5.3 Counter Description


3.5.3.1 C373220630 Number of Successful Security Mode
Definition

The counter is used to count the number of successful security activation.

Sampling Interval

Event triggered
3-22

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 3 Statistics of UE Context

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the SecurityModeComplete message from


the UE.
Sampling Point 2

Explanation

The eNodeB will send the SecurityModeCommand message to UE during


Initial UE Context setup. When it receives the SecurityModeComplete
message from UE,indicating successful security activation.

Updated

The counter is incremented by 1 when the eNodeB receives the


SecurityModeComplete message from the UE.

3.5.3.2 C373220631 Number of Failed Security Mode


Definition

The counter is used to count the number of security activation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the SecurityModefailure message from the UE.
Sampling Point 3

Explanation

The eNodeB will send the SecurityModeCommand message to UE


during Initial UE Context setup. When it receives the SecurityModefailure
message from UE,indicating security activation failures.

Updated

The counter is incremented by 1 when the eNodeB receives the


SecurityModefailure message from the UE.

3-23
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

3-24
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 4

Statistics of
S1/X2-connection
Table of Contents
UE-associated Logical S1-connection ........................................................................4-1
S1 Error Indication......................................................................................................4-3

4.1 UE-associated Logical S1-connection


4.1.1 Flow Charts and Sampling Points
Figure 4-1 UE-associated Logical S1-connection

l
l

Sampling Point 1: The eNodeB sends the InitialUEMessage to the MME.


Sampling Point 2: At first, the eNodeB receives the InitialUEContextSetupRequest,
InitialUEContextReleaseCommand, RESET or etc message.

4.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373495200

Number of Send Init UE Message by ENB

C373495201

Number of Received First Message by ENB after Init UE Message

4-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

4.1.3 Counter Description


4.1.3.1 C373495200 Number of Send Init UE Message by ENB
Definition

The counter is used to count the number of attempted UE-associated


logical S1-connection establishments from eNodeB to MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the InitialUEMessage to MME.


Sampling Point 1

Explanation

Transmission of an INITIAL UE MESSAGE by the eNodeB to the MME.

Updated

The counter is incremented by 1 when eNodeB sends InitialUEMessage


to the MME.

4.1.3.2 C373495201 Number of Received First Message by ENB after Init UE Message
Definition

The counter is used to count the number of successful UE-associated


logical S1-connection establishments from eNodeB to MME.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the first signal message from MME after
sending the InitialUEMessage.
Sampling Point 2

Explanation

On receipt by The eNodeB of first message from MME which succeeds


INITIAL UE MESSAGE message on an UE-associated logical
S1-connection.

Updated

The counter is incremented by 1 when eNodeB receives the first signal


message from the MME after sending the InitialUEMessage.

4-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 4 Statistics of S1/X2-connection

4.2 S1 Error Indication


4.2.1 Flow Charts and Sampling points
Figure 4-2 S1 Error Indication

l
l

Sampling Point 1: The eNodeB sends the ErrorIndication Message to the MME.
Sampling Point 2: The eNodeB receives the ErrorIndication message from the MME.

4.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373960440

Number of S1 Error Indications sent by eNB,Message Error Reasons

C373960441

Number of S1 Error Indications sent by eNB,Other Reasons

C373960442

Number of S1 Error Indications sent by MME,Message Error Reasons

C373960443

Number of S1 Error Indications sent by MME,Other Reasons

4.2.3 Counter Description


4.2.3.1 C373960440 Number of S1 Error Indications sent by eNB,Message Error
Reasons
Definition

The counter is used to count the number of Error Indication initiated by


eNB to MME for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
4-3

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the ErrorIndication message to the MME due to
parameter error.
Sampling Point 1

Explanation

After the eNodeB receive the message from the MME, it check the
parameter failed. Then the eNodeB sends the ErrorIndication message
to the MME.

Updated

When the eNodeB sends the ErrorIndication message to the MME due to
parameter error,the counter is incremented by 1.

4.2.3.2 C373960441 Number of S1 Error Indications sent by eNB,Other Reasons


Definition

The counter is used to count the number of Error Indication initiated by


eNB to MME for other error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the ErrorIndication message to the MME due
to other reason.
Sampling Point 1

Explanation

After the eNodeB receive the message from the MME, it occur other failed.
Then the eNodeB sends the ErrorIndication message to the MME.

Updated

When the eNodeB sends the ErrorIndication message to the MME due to
other reason,the counter is incremented by 1.

4.2.3.3 C373960442 Number of S1 Error Indications sent by MME,Message Error


Reasons
Definition

The counter is used to count the number of Error Indication initiated by


MME to eNodeB for parameter error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME
due to parameter error.
Sampling Point 2
4-4

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 4 Statistics of S1/X2-connection

Explanation

After the MME receive the message from the eNodeB, it check the
parameter failed. Then the MME sends the ErrorIndication message to
the eNodeB.

Updated

When the eNodeB receives the ErrorIndication message from the MME
due to parameter error,the counter is incremented by 1.

4.2.3.4 C373960443 Number of S1 Error Indications sent by MME,Other Reasons


Definition

The counter is used to count the number of Error Indication initiated by


MME to eNodeB for other error.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the ErrorIndication message from the MME
due to other reason.
Sampling Point 2

Explanation

After the MME receive the message from the eNodeB, it occur other failed.
Then the MME sends the ErrorIndication message to the eNodeB.

Updated

When the eNodeB receives the ErrorIndication message from the MME
due to other reason,the counter is incremented by 1.

4-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

4-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5

Statistics of SON
Table of Contents
MRO ..........................................................................................................................5-1
RACH.......................................................................................................................5-11
PCI...........................................................................................................................5-18
X2 Self Configuration ...............................................................................................5-49

5.1 MRO
5.1.1 Flow Charts and Sampling Points
MRO refers to that handover fault and unnecessary handover detection and optimize.
The statistics of MRO includes handover too late, handover too early and handover in error
cell.

5.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373474911

Number of Too Early Ho During Handover(Cell)

C373474912

Number of Too Early HO After Handover(Cell)

C373474913

Number of Too Late HO Before Handover(Cell)

C373474914

Number of Too Late HO During Handover(Cell)

C373474915

Number of HO in Error Cell During Handover(Cell)

C373474916

Number of HO in Error Cell After Handover(Cell)

C373474917

Number of Coverage Hole in Cell(Cell)

C373474918

Number of Coverage Hole between Cell(Cell)

C373474919

Number of No Neighbor Relation(Cell)

10

C373723000

Number of Failed Handover Executions Due to Handover Too Early

11

C373723001

Number of Failed Handover Executions Due to Handover Too Later

12

C373723002

Number of Failed Handover Executions Due to Handover Failed

13

C373723003

Number of Ping-Pong Handover

14

C373723004

Number of Too Early Ho During Handover(Cell Pair)


5-1

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
15

C373723005

Number of Too Early HO After Handover(Cell Pair)

16

C373723006

Number of Too Late HO Before Handover(Cell Pair)

17

C373723007

Number of Too Late HO During Handover(Cell Pair)

18

C373723008

Number of HO in Error Cell During Handover(Cell Pair)

19

C373723009

Number of HO in Error Cell After Handover(Cell Pair)

20

C373723011

Number of Coverage Holl between Cell(Cell Pair)

21

C373723012

Number of No Neighbor Relation(Cell Pair)

5.1.3 Counter Description


5.1.3.1 C373474911 Number of Too Early Ho During Handover(Cell)
Definition

The counter is used to count the number of handover too early during
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of


RLF in the source cell.

Explanation

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell,the counter is incremented by 1.

5.1.3.2 C373474912 Number of Too Early HO After Handover(Cell)


Definition

The counter is used to count the number of handover too late after
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

5-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When the UE occurs RRC reestablishment in source cell as a result of


RLF in the target cell.

Explanation

When the UE occurs RRC Reestablishment in source cell as a result of


RLF in the target cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in source cell as a result of


RLF in the target cell,the counter is incremented by 1.

5.1.3.3 C373474913 Number of Too Late HO Before Handover(Cell)


Definition

The counter is used to count the number of handover too early before
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport not reported before RLF.

Explanation

When the UE occurs RRC Reestablishment in target cell as a result of


RLF in the source cell and the MeasurementReport not reported before
RLF,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in target cell as a result of


RLF in the source cell and the MeasurementReport not reported before
RLF,the counter is incremented by 1.

5.1.3.4 C373474914 Number of Too Late HO During Handover(Cell)


Definition

The counter is used to count the number of handover too late during
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport reported before RLF.

Explanation

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport reported before RLF,it is
added to the counter.

5-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport reported before RLF,the
counter is incremented by 1.

5.1.3.5 C373474915 Number of HO in Error Cell During Handover(Cell)


Definition

The counter is used to count the number of handover too wrong cell during
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment in error cell as a result of RLF


in the source cell.

Explanation

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the source cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the source cell,the counter is incremented by 1.

5.1.3.6 C373474916 Number of HO in Error Cell After Handover(Cell)


Definition

The counter is used to count the number of handover too wrong cell after
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment in error cell as a result of RLF


in the target cell.

Explanation

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the target cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the target cell,the counter is incremented by 1.

5.1.3.7 C373474917 Number of Coverage Hole in Cell(Cell)


Definition

The counter is used to count the number of coverage hole in cell.


5-4

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment as a result of RLF in cell,and


the cause is other failures.

Explanation

When the UE occurs RRC reestablishment as a result of RLF in cell,and


the cause is other failures,it is added to the counter.

Updated

When the UE occurs RRC reestablishment as a result of RLF in cell,and


the cause is other failures,the counter is incremented by 1.

5.1.3.8 C373474918 Number of Coverage Hole between Cell(Cell)


Definition

The counter is used to count the number of coverage hole between cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell,and the cause is other failures.

Explanation

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell,and the cause is other failures,it is added to the counter.

Updated

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell,and the cause is other failures,the counter is incremented
by 1.

5.1.3.9 C373474919 Number of No Neighbor Relation(Cell)


Definition

The counter is used to count the number of no neighbor relation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB detects the PCI of the neighbour cell without
configuration.

5-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB detects the PCI of the neighbour cell without
configuration,it is added to the counter.

Updated

When the eNodeB detects the PCI of the neighbour cell without
configuration,the counter is incremented by 1.

5.1.3.10 C373723000 Number of Failed Handover Executions Due to Handover Too


Early
Definition

The counter is used to count the number of outgoing handover related


events that fail related with too early.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC Reestablishment as a result of RLF in the


source cell.

Explanation

When the UE occurs RRC Reestablishment as a result of RLF in the


source cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment as a result of RLF in the


source cell,the counter is incremented by 1.

5.1.3.11 C373723001 Number of Failed Handover Executions Due to Handover Too


Later
Definition

The counter is used to count the number of outgoing handover related


events that fail related with too late.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC Reestablishment as a result of RLF in the target


cell.

Explanation

When the UE occurs RRC Reestablishment as a result of RLF in the target


cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment as a result of RLF in the target


cell,the counter is incremented by 1.

5-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

5.1.3.12 C373723002 Number of Failed Handover Executions Due to Handover Failed


Definition

The counter is used to count the number of outgoing handover related


events that fail related with wrong cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC Reestablishment in error cell as a result of RLF.

Explanation

When the UE occurs RRC Reestablishment in error cell as a result of


RLF,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in error cell as a result of


RLF,the counter is incremented by 1.

5.1.3.13 C373723003 Number of Ping-Pong Handover


Definition

The counter is used to count the number of handover executions that fail
related with Ping-Pong.

Sampling Interval

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs handover from source cell to target cell, then occurs
handover back to source cell within the threshold of time successfully.

Explanation

When the UE occurs handover from source cell to target cell, then occurs
handover back to source cell within the threshold of time successfully,
it is added to the counter.

Updated

When the UE occurs handover from source cell to target cell, then occurs
handover back to source cell within the threshold of time successfully, the
counter is incremented by 1.

5.1.3.14 C373723004 Number of Too Early Ho During Handover(Cell Pair)


Definition

The counter is used to count the number of handover too early during
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
5-7

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of


RLF in the source cell.

Explanation

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell,the counter is incremented by 1.

5.1.3.15 C373723005 Number of Too Early HO After Handover(Cell Pair)


Definition

The counter is used to count the number of handover too late after
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in source cell as a result of


RLF in the target cell.

Explanation

When the UE occurs RRC Reestablishment in source cell as a result of


RLF in the target cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in source cell as a result of


RLF in the target cell,the counter is incremented by 1.

5.1.3.16 C373723006 Number of Too Late HO Before Handover(Cell Pair)


Definition

The counter is used to count the number of handover too late before
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport not reported before RLF.

Explanation

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport not reported before RLF,
it is added to the counter.

5-8
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Updated

When the UE occurs RRC Reestablishment in target cell as a result of


RLF in the source cell and the MeasurementReport not reported before
RLF, the counter is incremented by 1.

5.1.3.17 C373723007 Number of Too Late HO During Handover(Cell Pair)


Definition

The counter is used to count the number of handover too late during
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport reported before RLF.

Explanation

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport reported before RLF,it is
added to the counter.

Updated

When the UE occurs RRC Reestablishment in target cell as a result of RLF


in the source cell and the MeasurementReport reported before RLF,the
counter is incremented by 1.

5.1.3.18 C373723008 Number of HO in Error Cell During Handover(Cell Pair)


Definition

The counter is used to count the number of handover too wrong cell during
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in error cell as a result of RLF


in the source cell.

Explanation

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the source cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the source cell,the counter is incremented by 1.

5-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.1.3.19 C373723009 Number of HO in Error Cell After Handover(Cell Pair)


Definition

The counter is used to count the number of handover too wrong cell after
handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in error cell as a result of RLF


in the target cell.

Explanation

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the target cell,it is added to the counter.

Updated

When the UE occurs RRC Reestablishment in error cell as a result of RLF


in the target cell,the counter is incremented by 1.

5.1.3.20 C373723011 Number of Coverage Holl between Cell(Cell Pair)


Definition

The counter is used to count the number of coverage hole between cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell,and the cause is other failures.

Explanation

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell,and the cause is other failures,it is added to the counter.

Updated

When the UE occurs RRC reestablishment in target cell as a result of RLF


in the source cell,and the cause is other failures,the counter is incremented
by 1.

5.1.3.21 C373723012 Number of No Neighbor Relation(Cell Pair)


Definition

The counter is used to count the number of no neighbor relation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation
5-10

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When the eNodeB detects the PCI of the neighbour cell without
configuration.

Explanation

When the eNodeB detects the PCI of the neighbour cell without
configuration,it is added to the counter.

Updated

When the eNodeB detects the PCI of the neighbour cell without
configuration,the counter is incremented by 1.

5.2 RACH
5.2.1 Flow Charts and Sampling Points
No chart.

5.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373444757

Number of No RACH Dedicate Preamble Assigned

C373444758

Total Number of RACH Dedicate Preamble Assigned

C373444761

Times of Contention Based Random Access Initiated by Handover

C373444762

Times of Non-Contention Based Random Access Initiated by Handover

C373474902

UE Send Preamble Successfully with 1 Times

C373474903

UE Send Preamble Successfully with 2 Times

C373474904

UE Send Preamble Successfully with 3 Times

C373474905

UE Send Preamble Successfully with 4 Times

C373474906

UE Send Preamble Successfully with 5 Times

10

C373474907

UE Send Preamble Successfully with 5 More Times

11

C373474908

Number of UE which Have Contention in Access Procedure

12

C373474909

Number of UE which Have No Contention in Access Procedure

13

C373474927

Number of UE which Access Successfully by Sending 1 Preamble and No


Contention in Access Procedure

14

C373474928

Preamble Number Send by UE which Have No Contention in Access


Procedure

5-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.2.3 Counter Description


5.2.3.1 C373444757 Number of No RACH Dedicate Preamble Assigned
Definition

The counter is used to count the number of dedicated RACH preambles


failed to assign to UEs.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When all dedicated RACH preambles are assigned to UEs.

Explanation

The counter provides the number of dedicated RACH preambles failed to


assign to UEs.

Updated

The counter is incremented by 1 when all dedicated RACH preambles


are assigned to UEs.

5.2.3.2 C373444758 Total Number of RACH Dedicate Preamble Assigned


Definition

The counter is used to count the number of dedicated RACH preambles


assigned to UEs.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When a dedicated RACH preambles is assigned to UEs.

Explanation

The counter provides the number of dedicated RACH preambles assigned


to UEs.

Updated

The counter is incremented by 1 when a dedicated RACH preambles is


assigned to UEs.

5.2.3.3 C373444761 Times of Contention Based Random Access Initiated by Handover


Definition

The counter is used to count the number of contention based random


access initiated by handover.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times
5-12

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Measurement Object

Cell

Sampling Point

When all dedicated RACH preambles are assigned to UEs during handover
procedure.

Explanation

The counter provides the number of dedicated RACH preambles failed to


assign to UEs during handover procedure.

Updated

The counter is incremented by 1 when all dedicated RACH preambles are


assigned to UEs during handover procedure.

5.2.3.4 C373444762 Times of Non-Contention Based Random Access Initiated by


Handover
Definition

The counter is used to count the number of non-contention based random


access initiated by handover.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When a dedicated RACH preambles is assigned to UEs successfully


during handover procedure.

Explanation

The counter provides the number of dedicated RACH preambles assigned


to UEs during handover procedure.

Updated

The counter is incremented by 1 when a dedicated RACH preambles is


assigned to UEs successfully during handover procedure.

5.2.3.5 C373474902 UE Send Preamble Successfully with 1 Times


Definition

The counter is used to count the number of UE which access successfully


by sending 1 preamble.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UE INFORMATION RESPONSE message,


If UE access successfully by sending 1 preamble.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE. If UE access successfully by
sending 1 preamble,it is added to the counter.
5-13

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

When eNodeB enables SON RO function, eNodeB statistics random


access information of following access UE. If UE access successfully by
sending 1 preamble,the counter is increased by 1.

5.2.3.6 C373474903 UE Send Preamble Successfully with 2 Times


Definition

The counter is used to count the number of UE which access successfully


by sending 2 preambles.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UE INFORMATION RESPONSE


message,If UE access successfully by sending 2 preambles.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 2 preambles,it is added to the counter.

Updated

When eNodeB enables SON RO function, eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 2 preambles,the counter is increased by 1.

5.2.3.7 C373474904 UE Send Preamble Successfully with 3 Times


Definition

The counter is used to count the number of UE which access successfully


by sending 3 preambles.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UE INFORMATION RESPONSE


message,If UE access successfully by sending 3 preambles.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 3 preambles,it is added to the counter.

Updated

When eNodeB enables SON RO function, eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 3 preambles, the counter is increased by 1.

5-14
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

5.2.3.8 C373474905 UE Send Preamble Successfully with 4 Times


Definition

The counter is used to count the number of UE which access successfully


by sending 4 preambles.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UE INFORMATION RESPONSE


message,If UE access successfully by sending 4 preambles.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 4 preambles,it is added to the counter.

Updated

When eNodeB enables SON RO function, eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 4 preambles,the counter is increased by 1.

5.2.3.9 C373474906 UE Send Preamble Successfully with 5 Times


Definition

The counter is used to count the number of UE which access successfully


by sending 5 preambles.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UE INFORMATION RESPONSE


message,If UE access successfully by sending 5 preambles.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 5 preambles,it is added to the counter.

Updated

When eNodeB enables SON RO function, eNodeB statistics random


access information of following access UE.If UE access successfully by
sending 5 preambles,the counter is increased by 1.

5.2.3.10 C373474907 UE Send Preamble Successfully with 5 More Times


Definition

The counter is used to count the number of UE which access successfully


by sending more than 5 preambles.

5-15
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UE INFORMATION RESPONSE


message,If UE access successfully by sending more than 5 preambles.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE.If UE access successfully by
sending more than 5 preambles,it is added to the counter.

Updated

When eNodeB enables SON RO function, eNodeB statistics random


access information of following access UE.If UE access successfully by
sending more than 5 preambles,the counter is increased by 1.

5.2.3.11 C373474908 Number of UE which Have Contention in Access Procedure


Definition

The counter is used to count the number of UE which have contention


in access procedure.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the UE report its random access information to eNodeB.

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE. If UE have contention in access
procedure,it is added to the counter.

Updated

When the UE report its random access information to eNodeB,and the UE


have contention in access procedure,the counter is increased by 1.

5.2.3.12 C373474909 Number of UE which Have No Contention in Access Procedure


Definition

The counter is used to count the number of UE which free contention in


access procedure.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the UE report its random access information to eNodeB.


5-16

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Explanation

When eNodeB enables SON RO function,eNodeB statistics random


access information of following access UE. If UE free contention in access
procedure,it is added to the counter.

Updated

When the UE report its random access information to eNodeB,and the UE


have no contention in access procedure,the counter is increased by 1.

5.2.3.13 C373474927 Number of UE which Access Successfully by Sending 1 Preamble


and No Contention in Access Procedure
Definition

The counter is used to count the number of UE which access successfully


by sending 1 preamble and free contention in access procedure.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the UE report its random access information to eNB.

Explanation

When eNB enables SON RO function, eNB statistics random access


information of following access UE. If UE access successfully by sending
1 preamble and free contention in access procedure, this is added to the
counter.

Updated

When eNB enables SON RO function, eNB statistics random access


information of following access UE. If UE access successfully by sending
1 preamble and free contention in access procedure, this counter is
increased by 1.

5.2.3.14 C373474928 Preamble Number Send by UE which Have No Contention in


Access Procedure
Definition

The counter is used to count the preamble number send by UE which


free contention in access procedure.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the UE report its random access information to eNB.

Explanation

When eNB enables SON RO function, eNB statistics random access


information of following access UE. If UE free contention and this UE send
preamble number is Ns in access procedure, it is added to the counter.
5-17

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

When eNB enables SON RO function, eNB statistics random access


information of following access UE. If UE free contention and this UE send
preamble number is Ns in access procedure,this counter is increased by
Ns.

5.3 PCI
5.3.1 Flow Charts and Sampling Points
No chart.

5.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373474900

Number of PCI Conflict(Cell)

C373474901

Number of PCI Confusion(Cell)

C373474920

Number of Different Detect Cell intra RAT

C373474921

Number of Report Detect Cell intra RAT

C373474922

Number of ReportCGI by UE intra RAT

C373474923

Number of ReportCGI by Period intra RAT

C373474924

Number of Successful ReportCGI by Period intra RAT

C373474925

Number of Report Neighbor Relation Addition to OMC intra RAT

C373474942

Number of Different Detect Cell between LTE and UTRAN

10

C373474943

Number of Report Detect Cell between LTE and UTRAN

11

C373474944

Number of ReportCGI by UE between LTE and UTRAN

12

C373474945

Number of ReportCGI by Period between LTE and UTRAN

13

C373474946

Number of Successful ReportCGI by Period between LTE and UTRAN

14

C373474947

Number of Report Neighbor Relation Addition to OMC between LTE and


UTRAN

15

C373474948

Number of Different Detect Cell between LTE and CDMA

16

C373474949

Number of Report Detect Cell between LTE and CDMA

17

C373474950

Number of ReportCGI by UE between LTE and CDMA

18

C373474951

Number of ReportCGI by Period between LTE and CDMA

19

C373474952

Number of Successful ReportCGI by Period between LTE and CDMA

5-18
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

NO.

Counter

Counter Name

Number
20

C373474953

Number of Report Neighbor Relation Addition to OMC between LTE and


CDMA

21

C373474954

Number of Different Detect Cell between LTE and GSM

22

C373474955

Number of Report Detect Cell between LTE and GSM

23

C373474956

Number of ReportCGI by UE between LTE and GSM

24

C373474957

Number of ReportCGI by Period between LTE and GSM

25

C373474958

Number of Successful ReportCGI by Period between LTE and GSM

26

C373474959

Number of Report Neighbor Relation Addition to OMC between LTE and


GSM

27

C373474960

Number of Successful Neighbor Cell Addition Intra RAT

28

C373474961

Number of Successful Handover to Temp Neighbor Cell Intra RAT

29

C373474962

Number of Failed Handover to Temp Neighbor Cell Intra RAT

30

C373474963

Number of Report Neighbor Relation Deletion to OMC Intra RAT

31

C373474964

Number of Successfully Deleted Official Neighbor Cell Intra RAT

32

C373474965

Number of Successful Addition of Official Neighbor Cell between LTE and


UTRAN

33

C373474966

Number of Successful Handover to Temp Neighbor Cell between LTE and


UTRAN

34

C373474967

Number of Failed Handover to Temp Neighbor Cell between LTE and UTRAN

35

C373474968

Number of Report Neighbor Relation Deletion to OMC between LTE and


UTRAN

36

C373474969

Number of Successfully Deleted Official Neighbor Cell between LTE and


UTRAN

37

C373474970

Number of Successful Addition of Official Neighbor Cell between LTE and


CDMA

38

C373474971

Number of Successful Handover to Temp Neighbor Cell between LTE and


CDMA

39

C373474972

Number of Failed Handover to Temp Neighbor Cell between LTE and CDMA

40

C373474973

Number of Report Neighbor Relation Deletion to OMC between LTE and


CDMA

41

C373474974

Number of Successfully Deleted Official Neighbor Cell between LTE and


CDMA

42

C373474975

Number of Successful Addition of Official Neighbor Cell between LTE and


GSM

5-19
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
43

C373474976

Number of Successful Handover to Temp Neighbor Cell between LTE and


GSM

44

C373474977

Number of Failed Handover to Temp Neighbor Cell between LTE and GSM

45

C373474978

Number of Report Neighbor Relation Deletion to OMC between LTE and


GSM

46

C373474979

Number of Successfully Deleted Official Neighbor Cell between LTE and


GSM

47

C373474980

Number of Temp Neighbor Cell Intra RAT

48

C373474981

Number of Temp Neighbor Cell between LTE and UTRAN

49

C373474982

Number of Temp Neighbor Cell between LTE and CDMA

50

C373474983

Number of Temp Neighbor Cell between LTE and GSM

51

C373474984

Number of not Meeting Normal Neighbour Relation Addition Condition intra


RAT

52

C373474985

Number of not Sending Normal Neighbour Relation Addition Request


because of Full intra RAT

53

C373474986

Number of not Meeting Normal Neighbour Relation Addition Condition


between LTE and UTRAN

54

C373474987

Number of not Sending Normal Neighbour Relation Addition Request


because of Full between LTE and UTRAN

55

C373474988

Number of not Meeting Normal Neighbour Relation Addition Condition


between LTE and CDMA

56

C373474989

Number of not Sending Normal Neighbour Relation Addition Request


because of Full between LTE and CDMA

57

C373474990

Number of not Meeting Normal Neighbour Relation Addition Condition


between LTE and GSM

58

C373474991

Number of not Sending Normal Neighbour Relation Addition Request


because of Full between LTE and GSM

59

C373692700

Number of Intra-freq Neighbour Cell Reported by UE

60

C373692701

Number of Inter-freq Neighbour Cell Reported by UE

61

C373692702

Number of Inter-RAT(LTE->UTRAN)Neighbour Cell Reported by UE

62

C373692703

Number of Inter-RAT(LTE->CDMA)Neighbour Cell Reported by UE

63

C373692704

Number of Inter-RAT(LTE->GSM)Neighbour Cell Reported by UE

64

C373723013

Number of PCI Conflict(Cell Pair)

65

C373723014

Number of PCI Confusion(Cell Pair)

5-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

5.3.3 Counter Description


5.3.3.1 C373474900 Number of PCI Conflict(Cell)
Definition

The counter is used to count the number of the service cell PCI same
to the neighbour cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB detects that the neighbour's PCI is the same to the
serving cell.

Explanation

When the eNodeB detects that the neighbour's PCI is the same to the
serving cell, it is added to the counter.

Updated

When the eNodeB detects that the neighbour's PCI is the same to the
serving cell, the counter is incremented by 1.

5.3.3.2 C373474901 Number of PCI Confusion(Cell)


Definition

The counter is used to count the number of detecting the two neighbour
cells PCI being the same.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB detects that the two neighbours' PCI is the same.

Explanation

When the eNodeB detects that the two neighbours' PCI is the same, it is
added to the counter.

Updated

When the eNodeB detects that the two neighbours' PCI is the same,the
counter is incremented by 1.

5.3.3.3 C373474920 Number of Different Detect Cell intra RAT


Definition

The counter is used to count the number of different PCIs intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
5-21

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the different LTE unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the


UE in which the LTE unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by PCI number when the eNodeB receives


the MeasurementReport message from the UE in which the different LTE
unknown PCIs are detected intra RAT.

5.3.3.4 C373474921 Number of Report Detect Cell intra RAT


Definition

The counter is used to count the number of unknown PCI reports intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the LTE unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the


UE in which the LTE unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


MeasurementReport message from the UE in which the LTE unknown
PCIs are detected intra RAT.

5.3.3.5 C373474922 Number of ReportCGI by UE intra RAT


Definition

The counter is used to count the number of CGI to UE intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message


to UE which purpose is ReportCGI of LTE cell.

Explanation

When the eNodeB sends the RRCConnectionReconfiguration message to


UE which purpose is ReportCGI of LTE cell,it is added to the counter.

5-22
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to UE which purpose is
ReportCGI of LTE cell.

5.3.3.6 C373474923 Number of ReportCGI by Period intra RAT


Definition

The counter is used to count the number of CGI intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB is triggered to send a ReportCGI MESConfig to UE


of LTE cell.

Explanation

When the eNodeB is triggered to send a ReportCGI MESConfig to UE of


LTE cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB is triggered to send a


ReportCGI MESConfig to UE of LTE cell.

5.3.3.7 C373474924 Number of Successful ReportCGI by Period intra RAT


Definition

The counter is used to count the number of CGI reported by UE to eNodeB


intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about LTE cell from the UE.

Explanation

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about LTE cell from the UE,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


'ReportCGI' MeasurementReport message about LTE cell from the UE.

5.3.3.8 C373474925 Number of Report Neighbor Relation Addition to OMC intra RAT
Definition

The counter is used to count the number of adding Neighbor Relation


intra RAT.
5-23

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the NeighbourRelation Adding message of LTE


cell to the OMC.

Explanation

When the eNodeB sends the NeighbourRelation Adding message of LTE


cell to the OMC,it is added to the counter.

Updated

The counter is incremented by 1 When the eNodeB sends the


NeighbourRelation Adding message of LTE cell to the OMC.

5.3.3.9 C373474942 Number of Different Detect Cell between LTE and UTRAN
Definition

The counter is used to count the number of different PCIs between LTE
and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the different UTRAN unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the UE


in which the UTRAN unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by PCI number when the eNodeB receives the
MeasurementReport message from the UE in which the different UTRAN
unknown PCIs are detected.

5.3.3.10 C373474943 Number of Report Detect Cell between LTE and UTRAN
Definition

The counter is used to count the number of unknown PCI reports between
LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the UTRAN unknown PCIs are detected.
5-24

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Explanation

When the eNodeB receives the MeasurementReport message from the UE


in which the UTRAN unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


MeasurementReport message from the UE in which the UTRAN unknown
PCIs are detected.

5.3.3.11 C373474944 Number of ReportCGI by UE between LTE and UTRAN


Definition

The counter is used to count the number of CGI to UE between EUTRAN


and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


UE which purpose is ReportCGI of UTRAN cell.

Explanation

When the eNodeB sends the RRCConnectionReconfiguration message to


UE which purpose is ReportCGI of UTRAN cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to UE which purpose is
ReportCGI of UTRAN cell.

5.3.3.12 C373474945 Number of ReportCGI by Period between LTE and UTRAN


Definition

The counter is used to count the number of CGI between EUTRAN and
UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB is triggered to send a ReportCGI MESConfig to UE


of UTRAN cell.

Explanation

When the eNodeB is triggered to send a ReportCGI MESConfig to UE of


UTRAN cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB is triggered to send


a ReportCGI MESConfig to UE of UTRAN cell.

5-25
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.3.3.13 C373474946 Number of Successful ReportCGI by Period between LTE and


UTRAN
Definition

The counter is used to count the number of CGI reported by UE to eNodeB


between EUTRAN and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about UTRAN cell from the UE.

Explanation

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about UTRAN cell from the UE,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


'ReportCGI' MeasurementReport message about UTRAN cell from the UE.

5.3.3.14 C373474947 Number of Report Neighbor Relation Addition to OMC between


LTE and UTRAN
Definition

The counter is used to count the number of adding Neighbor Relation


between EUTRAN and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the NeighbourRelation Adding message of


UTRAN cell to the OMC.

Explanation

When the eNodeB sends the NeighbourRelation Adding message of


UTRAN cell to the OMC,it is added to the counter.

Updated

The counter is incremented by 1 When the eNodeB sends the


NeighbourRelation Adding message of UTRAN cell to the OMC.

5.3.3.15 C373474948 Number of Different Detect Cell between LTE and CDMA
Definition

The counter is used to count the number of different PCIs between LTE
and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative
5-26

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the different CDMA unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the UE


in which the CDMA unknown PCIs are detected, it is added to the counter.

Updated

The counter is incremented by PCI number when the eNodeB receives the
MeasurementReport message from the UE in which the different CDMA
unknown PCIs are detected.

5.3.3.16 C373474949 Number of Report Detect Cell between LTE and CDMA
Definition

The counter is used to count the number of unknown PCI reports between
LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the CDMA unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the UE


in which the CDMA unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


MeasurementReport message from the UE in which the CDMA unknown
PCIs are detected

5.3.3.17 C373474950 Number of ReportCGI by UE between LTE and CDMA


Definition

The counter is used to count the number of CGI to UE between LTE and
CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


UE which purpose is ReportCGI of CDMA cell.

5-27
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB sends the RRCConnectionReconfiguration message to


UE which purpose is ReportCGI of CDMA cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to UE which purpose is
ReportCGI of CDMA cell.

5.3.3.18 C373474951 Number of ReportCGI by Period between LTE and CDMA


Definition

The counter is used to count the number of CGI between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB is triggered to send a ReportCGI MESConfig to UE of


CDMA cell.

Explanation

When the eNodeB is triggered to send a ReportCGI MESConfig to UE of


CDMA cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB is triggered to send


a ReportCGI MESConfig to UE of CDMA cell.

5.3.3.19 C373474952 Number of Successful ReportCGI by Period between LTE and


CDMA
Definition

The counter is used to count the number of CGI reported by UE to eNodeB


between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about CDMA cell from the UE.

Explanation

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about CDMA cell from the UE,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


'ReportCGI' MeasurementReport message about CDMA cell from the UE.

5-28
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

5.3.3.20 C373474953 Number of Report Neighbor Relation Addition to OMC between


LTE and CDMA
Definition

The counter is used to count the number of adding Neighbor Relation


between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the NeighbourRelation Adding message of


CDMA cell to the OMC.

Explanation

When the eNodeB sends the NeighbourRelation Adding message of


CDMA cell to the OMC,it is added to the counter.

Updated

The counter is incremented by 1 When the eNodeB sends the


NeighbourRelation Adding message of CDMA cell to the OMC.

5.3.3.21 C373474954 Number of Different Detect Cell between LTE and GSM
Definition

The counter is used to count the number of different PCIs between LTE
and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the different GSM unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the UE


in which the GSM unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by PCI number when the eNodeB receives the
MeasurementReport message from the UE in which the different GSM
unknown PCIs are detected.

5.3.3.22 C373474955 Number of Report Detect Cell between LTE and GSM
Definition

The counter is used to count the number of unknown PCI reports between
LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative
5-29

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the MeasurementReport message from the


UE in which the GSM unknown PCIs are detected.

Explanation

When the eNodeB receives the MeasurementReport message from the UE


in which the GSM unknown PCIs are detected,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


MeasurementReport message from the UE in which the GSM unknown
PCIs are detected.

5.3.3.23 C373474956 Number of ReportCGI by UE between LTE and GSM


Definition

The counter is used to count the number of CGI to UE between LTE and
GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message


to UE which purpose is ReportCGI of GSM cell.

Explanation

When the eNodeB sends the RRCConnectionReconfiguration message to


UE which purpose is ReportCGI of GSM cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to UE which purpose is
ReportCGI of GSM cell.

5.3.3.24 C373474957 Number of ReportCGI by Period between LTE and GSM


Definition

The counter is used to count the number of CGI between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB is triggered to send a ReportCGI MESConfig to UE


of GSM cell.

Explanation

When the eNodeB is triggered to send a ReportCGI MESConfig to UE of


GSM cell,it is added to the counter.
5-30

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Updated

The counter is incremented by 1 when the eNodeB is triggered to send a


ReportCGI MESConfig to UE of GSM cell.

5.3.3.25 C373474958 Number of Successful ReportCGI by Period between LTE and


GSM
Definition

The counter is used to count the number of CGI reported by UE to eNodeB


between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about GSM cell from the UE.

Explanation

When the eNodeB receives the 'ReportCGI' MeasurementReport message


about GSM cell from the UE,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


'ReportCGI' MeasurementReport message about GSM cell from the UE.

5.3.3.26 C373474959 Number of Report Neighbor Relation Addition to OMC between


LTE and GSM
Definition

The counter is used to count the number of adding Neighbor Relation


between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the NeighbourRelation Adding message of GSM


cell to the OMC.

Explanation

When the eNodeB sends the NeighbourRelation Adding message of GSM


cell to the OMC,it is added to the counter.

Updated

The counter is incremented by 1 When the eNodeB sends the


NeighbourRelation Adding message of GSM cell to the OMC.

5-31
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.3.3.27 C373474960 Number of Successful Neighbor Cell Addition Intra RAT


Definition

The counter is used to count the number of successful normal neighbor


cell addition intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation of LTE cell to the OMC, and
the neighbor relation added successful.

Explanation

When the eNodeB reported neighbor relation of LTE cell to the OMC, and
the neighbor relation added successful, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation of LTE cell to the OMC, and the neighbor relation added successful.

5.3.3.28 C373474961 Number of Successful Handover to Temp Neighbor Cell Intra RAT
Definition

The counter is used to count the number of successful handover to temp


neighbor cell intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE handover to the LTE temporary neighbor cell successfully.

Explanation

When the UE handover to the LTE temporary neighbor cell successfully,


it is added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the LTE


temporary neighbor cell successfully.

5.3.3.29 C373474962 Number of Failed Handover to Temp Neighbor Cell Intra RAT
Definition

The counter is used to count the number of failed handover to temp


neighbor cell intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell
5-32

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When the UE handover to the LTE temporary neighbor cell failed.

Explanation

When the UE handover to the LTE temporary neighbor cell failed, it is


added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the LTE


temporary neighbor cell failed.

5.3.3.30 C373474963 Number of Report Neighbor Relation Deletion to OMC Intra RAT
Definition

The counter is used to count the number of report neighbor relation


deletion to OMC intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbour relation deleting message of LTE


cell to the OMC.

Explanation

When the eNodeB reported neighbour relation deleting message of LTE


cell to the OMC, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbour


relation deleting message of LTE cell to the OMC.

5.3.3.31 C373474964 Number of Successfully Deleted Official Neighbor Cell Intra RAT
Definition

The counter is used to count the number of successfully deleted normal


neighbor cell intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation deletion of LTE cell to the
OMC, and the neighbor relation deleted successful.

Explanation

When the eNodeB reported neighbor relation deletion of LTE cell to the
OMC,and the neighbor relation deleted successful, it is added to the
counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation deletion of LTE cell to the OMC, and the neighbor relation deleted
successful.
5-33

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.3.3.32 C373474965 Number of Successful Addition of Official Neighbor Cell between


LTE and UTRAN
Definition

The counter is used to count the number of successful addition of normal


neighbor cell between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation of UTRAN cell to the OMC,
and the neighbor relation added successful.

Explanation

When the eNodeB reported neighbor relation of UTRAN cell to the OMC,
and the neighbor relation added successful,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation of UTRAN cell to the OMC, and the neighbor relation added
successful.

5.3.3.33 C373474966 Number of Successful Handover to Temp Neighbor Cell between


LTE and UTRAN
Definition

The counter is used to count the number of successful handover to


temporary neighbor cell between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE handover to the UTRAN temporary neighbor cell successfully.

Explanation

When the UE handover to the UTRAN temporary neighbor cell successfully,


it is added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the UTRAN


temporary neighbor cell successfully.

5.3.3.34 C373474967 Number of Failed Handover to Temp Neighbor Cell between LTE
and UTRAN
Definition

The counter is used to count the number of failed handover to temporary


neighbor cell between LTE and UTRAN.

Sampling Interval

Event triggered
5-34

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE handover to the UTRAN temporary neighbor cell failed.

Explanation

When the UE handover to the UTRAN temporary neighbor cell failed, it is


added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the UTRAN


temporary neighbor cell failed.

5.3.3.35 C373474968 Number of Report Neighbor Relation Deletion to OMC between


LTE and UTRAN
Definition

The counter is used to count the number of report neighbor relation


deletion to OMC between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbour relation deleting message of


UTRAN cell to the OMC.

Explanation

When the eNodeB reported neighbour relation deleting message of


UTRAN cell to the OMC, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbour


relation deleting message of UTRAN cell to the OMC.

5.3.3.36 C373474969 Number of Successfully Deleted Official Neighbor Cell between


LTE and UTRAN
Definition

The counter is used to count the number of successfully deleted normal


neighbor cell between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation deletion of UTRAN cell to the
OMC,and the neighbor relation deleted successful.

5-35
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB reported neighbor relation deletion of UTRAN cell to


the OMC,and the neighbor relation deleted successful, it is added to the
counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation deletion of UTRAN cell to the OMC, and the neighbor relation
deleted successful.

5.3.3.37 C373474970 Number of Successful Addition of Official Neighbor Cell between


LTE and CDMA
Definition

The counter is used to count the number of successful addition of normal


neighbor cell between LTE and CDMA

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation of CDMA cell to the OMC,
and the neighbor relation added successful.

Explanation

When the eNodeB reported neighbor relation of CDMA cell to the OMC,and
the neighbor relation added successful, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation of CDMA cell to the OMC, and the neighbor relation added
successful.

5.3.3.38 C373474971 Number of Successful Handover to Temp Neighbor Cell between


LTE and CDMA
Definition

The counter is used to count the number of successful handover to


temporary neighbor cell between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE handover to the CDMA temporary neighbor cell successfully.

Explanation

When the UE handover to the CDMA temporary neighbor cell successfully,


it is added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the CDMA


temporary neighbor cell successfully.
5-36

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

5.3.3.39 C373474972 Number of Failed Handover to Temp Neighbor Cell between LTE
and CDMA
Definition

The counter is used to count the number of failed handover to temporary


neighbor cell between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE handover to the CDMA temporary neighbor cell failed.

Explanation

When the UE handover to the CDMA temporary neighbor cell failed, it is


added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the CDMA


temporary neighbor cell failed.

5.3.3.40 C373474973 Number of Report Neighbor Relation Deletion to OMC between


LTE and CDMA
Definition

The counter is used to count the number of report neighbor relation


deletion to OMC between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbour relation deleting message of CDMA


cell to the OMC.

Explanation

When the eNodeB reported neighbour relation deleting message of CDMA


cell to the OMC, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbour


relation deleting message of CDMA cell to the OMC.

5.3.3.41 C373474974 Number of Successfully Deleted Official Neighbor Cell between


LTE and CDMA
Definition

The counter is used to count the number of successfully deleted normal


neighbor cell between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative
5-37

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation deletion of CDMA cell to the
OMC,and the neighbor relation deleted successful.

Explanation

When the eNodeB reported neighbor relation deletion of CDMA cell to


the OMC, and the neighbor relation deleted successful, it is added to the
counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation deletion of CDMA cell to the OMC, and the neighbor relation
deleted successful.

5.3.3.42 C373474975 Number of Successful Addition of Official Neighbor Cell between


LTE and GSM
Definition

The counter is used to count the number of successful addition of normal


neighbor cell between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation of GSM cell to the OMC,and
the neighbor relation added successful.

Explanation

When the eNodeB reported neighbor relation of GSM cell to the OMC,and
the neighbor relation added successful, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation of GSM cell to the OMC, and the neighbor relation added
successful.

5.3.3.43 C373474976 Number of Successful Handover to Temp Neighbor Cell between


LTE and GSM
Definition

The counter is used to count the number of successful handover to


temporary neighbor cell between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

5-38
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When the UE handover to the GSM temporary neighbor cell successfully.

Explanation

When the UE handover to the GSM temporary neighbor cell successfully,


it is added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the GSM


temporary neighbor cell successfully.

5.3.3.44 C373474977 Number of Failed Handover to Temp Neighbor Cell between LTE
and GSM
Definition

The counter is used to count the number of failed handover to temporary


neighbor cell between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UE handover to the GSM temporary neighbor cell failed.

Explanation

When the UE handover to the GSM temporary neighbor cell failed, it is


added to the counter.

Updated

The counter is incremented by 1 when the UE handover to the GSM


temporary neighbor cell failed.

5.3.3.45 C373474978 Number of Report Neighbor Relation Deletion to OMC between


LTE and GSM
Definition

The counter is used to count the number of report neighbor relation


deletion to OMC between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbour relation deleting message of GSM


cell to the OMC.

Explanation

When the eNodeB reported neighbour relation deleting message of GSM


cell to the OMC, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbour


relation deleting message of GSM cell to the OMC.

5-39
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.3.3.46 C373474979 Number of Successfully Deleted Official Neighbor Cell between


LTE and GSM
Definition

The counter is used to count the number of successfully deleted normal


neighbor cell between LTE and GSM

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reported neighbor relation deletion of GSM cell to the
OMC, and the neighbor relation deleted successful.

Explanation

When the eNodeB reported neighbor relation deletion of GSM cell to


the OMC,and the neighbor relation deleted successful, it is added to the
counter.

Updated

The counter is incremented by 1 when the eNodeB reported neighbor


relation deletion of GSM cell to the OMC, and the neighbor relation deleted
successful.

5.3.3.47 C373474980 Number of Temp Neighbor Cell Intra RAT


Definition

The counter is used to count the number of temporary neighbor cell intra
RAT.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the number of temporary neighbor cell intra RAT is altered.

Explanation

When the number of temporary neighbor cell intra RAT is altered, it is


modified the counter.

Updated

The counter is modified when the number of temporary neighbor cell intra
RAT is altered.

5.3.3.48 C373474981 Number of Temp Neighbor Cell between LTE and UTRAN
Definition

The counter is used to count the number of temporary neighbor cell


between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Modification
5-40

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Unit

Unit

Measurement Object

Cell

Sampling Point

When the number of temporary neighbor cell between LTE and UTRAN is
altered.

Explanation

When the number of temporary neighbor cell between LTE and UTRAN is
altered, it is modified the counter.

Updated

The counter is modified when the number of temporary neighbor cell


between LTE and UTRAN is altered.

5.3.3.49 C373474982 Number of Temp Neighbor Cell between LTE and CDMA
Definition

The counter is used to count the number of temporary neighbor cell


between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the number of temporary neighbor cell between LTE and CDMA is
altered.

Explanation

When the number of temporary neighbor cell between LTE and CDMA is
altered, it is modified the counter.

Updated

The counter is modified when the number of temporary neighbor cell


between LTE and CDMA is altered.

5.3.3.50 C373474983 Number of Temp Neighbor Cell between LTE and GSM
Definition

The counter is used to count the number of temporary neighbor cell


between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Unit

Measurement Object

Cell

Sampling Point

When the number of temporary neighbor cell between LTE and GSM is
altered.

Explanation

When the number of temporary neighbor cell between LTE and GSM is
altered, it is modified the counter.

5-41
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is modified when the number of temporary neighbor cell


between LTE and GSM is altered.

5.3.3.51 C373474984 Number of not Meeting Normal Neighbour Relation Addition


Condition intra RAT
Definition

The counter is used to count the number of not meeting normal neighbour
relation addition condition intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation can't meet the normal neighbour relation
addition condition intra RAT.

Explanation

The counter provides the number of intra-RAT temporary neighbour relation


which not meet the normal neighbour relation addition condition intra RAT.

Updated

The counter is incremented by 1 when the statistic duration is end and the
statistic result of the intra-RAT temporary neighbour relation can't meet the
normal neighbour relation addition condition intra RAT.

5.3.3.52 C373474985 Number of not Sending Normal Neighbour Relation Addition


Request because of Full intra RAT
Definition

The counter is used to count the number of not sending normal neighbour
relation addition request because of full intra RAT.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation meets the normal neighbour relation addition
condition, but the eNodeB does not send addition request because of that
the normal neighbour relation list is full intra RAT.

Explanation

The counter provides the number of not sending intra-RAT ANR neighbour
relation addition request because of that the normal neighbour relation
list is full intra RAT.

5-42
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Updated

The counter is incremented by 1 when the statistic duration is end and


the statistic result of the intra-RAT temporary neighbour relation meets
the normal neighbour relation addition condition, but the eNodeB does
not send addition request because of that the normal neighbour relation
list is full intra RAT.

5.3.3.53 C373474986 Number of not Meeting Normal Neighbour Relation Addition


Condition between LTE and UTRAN
Definition

The counter is used to count the number of not meeting normal neighbour
relation addition condition between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation can't meet the normal neighbour relation
addition condition between LTE and UTRAN.

Explanation

The counter provides the number of intra-RAT temporary neighbour


relation which not meet the normal neighbour relation addition condition
between LTE and UTRAN.

Updated

The counter is incremented by 1 when the statistic duration is end and the
statistic result of the intra-RAT temporary neighbour relation can't meet the
normal neighbour relation addition condition between LTE and UTRAN.

5.3.3.54 C373474987 Number of not Sending Normal Neighbour Relation Addition


Request because of Full between LTE and UTRAN
Definition

The counter is used to count the number of not sending normal neighbour
relation addition request because of full between LTE and UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation meets the normal neighbour relation addition
condition, but the eNodeB does not send addition request because of that
the normal neighbour relation list is full between LTE and UTRAN.

5-43
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the number of not sending intra-RAT ANR neighbour
relation addition request because of that the normal neighbour relation list
is full between LTE and UTRAN.

Updated

The counter is incremented by 1 when the statistic duration is end and the
statistic result of the intra-RAT temporary neighbour relation meets the
normal neighbour relation addition condition, but the eNodeB does not
send addition request because of that the normal neighbour relation list
is full between LTE and UTRAN.

5.3.3.55 C373474988 Number of not Meeting Normal Neighbour Relation Addition


Condition between LTE and CDMA
Definition

The counter is used to count the number of not meeting normal neighbour
relation addition condition between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation can't meet the normal neighbour relation
addition condition between LTE and CDMA.

Explanation

The counter provides the number of intra-RAT temporary neighbour


relation which not meet the normal neighbour relation addition condition
between LTE and CDMA.

Updated

The counter is incremented by 1 when the statistic duration is end and the
statistic result of the intra-RAT temporary neighbour relation can't meet the
normal neighbour relation addition condition between LTE and CDMA.

5.3.3.56 C373474989 Number of not Sending Normal Neighbour Relation Addition


Request because of Full between LTE and CDMA
Definition

The counter is used to count the number of not sending normal neighbour
relation addition request because of full between LTE and CDMA.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

5-44
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation meets the normal neighbour relation addition
condition, but the eNodeB does not send addition request because of that
the normal neighbour relation list is full between LTE and CDMA.

Explanation

The counter provides the number of not sending intra-RAT ANR neighbour
relation addition request because of that the normal neighbour relation
list is full between LTE and CDMA.

Updated

The counter is incremented by 1 when the statistic duration is end and


the statistic result of the intra-RAT temporary neighbour relation meets
the normal neighbour relation addition condition, but the eNodeB does
not send addition request because of that the normal neighbour relation
list is full between LTE and CDMA.

5.3.3.57 C373474990 Number of not Meeting Normal Neighbour Relation Addition


Condition between LTE and GSM
Definition

The counter is used to count the number of not meeting normal neighbour
relation addition condition between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation can't meet the normal neighbour relation
addition condition between LTE and GSM.

Explanation

The counter provides the number of intra-RAT temporary neighbour


relation which not meet the normal neighbour relation addition condition
between LTE and GSM.

Updated

The counter is incremented by 1 when the statistic duration is end and the
statistic result of the intra-RAT temporary neighbour relation can't meet the
normal neighbour relation addition condition between LTE and GSM.

5.3.3.58 C373474991 Number of not Sending Normal Neighbour Relation Addition


Request because of Full between LTE and GSM
Definition

The counter is used to count the number of not sending normal neighbour
relation addition request because of full between LTE and GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative
5-45

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the statistic duration is end and the statistic result of the intra-RAT
temporary neighbour relation meets the normal neighbour relation addition
condition, but the eNodeB does not send addition request because of that
the normal neighbour relation list is full between LTE and GSM.

Explanation

The counter provides the number of not sending intra-RAT ANR neighbour
relation addition request because of that the normal neighbour relation
list is full between LTE and GSM.

Updated

The counter is incremented by 1 when the statistic duration is end and


the statistic result of the intra-RAT temporary neighbour relation meets
the normal neighbour relation addition condition, but the eNodeB does
not send addition request because of that the normal neighbour relation
list is full between LTE and GSM.

5.3.3.59 C373692700 Number of Intra-freq Neighbour Cell Reported by UE


Definition

The counter is used to count the number of intra-frequence neighbour


cell reported by UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When a LTE intra-frequence neighbour cell reported by UE in the


MeasurementReqport for handover.

Explanation

The counter provides the number of intra-frequence neighbour cell


reported by UE.

Updated

The counter is incremented by 1 when a LTE intra-frequence neighbour


cell reported by UE in the MeasurementReqport for handover.

5.3.3.60 C373692701 Number of Inter-freq Neighbour Cell Reported by UE


Definition

The counter is used to count the number of inter-frequence neighbour


cell reported by UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation
5-46

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When a LTE inter-frequence neighbour cell reported by UE in the


MeasurementReqport for handover.

Explanation

The counter provides the number of inter-frequence neighbour cell


reported by UE.

Updated

The counter is incremented by 1 when a LTE inter-frequence neighbour


cell reported by UE in the MeasurementReqport for handover.

5.3.3.61 C373692702 Number of Inter-RAT(LTE->UTRAN)Neighbour Cell Reported


by UE
Definition

The counter is used to count the number of inter-RAT(LTE>UTRAN)neighbour cell reported by UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When a UTRAN neighbour cell reported by UE in the MeasurementReqport


for handover.

Explanation

The counter provides the number of UTRAN neighbour cell reported by UE.

Updated

The counter is incremented by 1 when a UTRAN neighbour cell reported


by UE in the MeasurementReqport for handover.

5.3.3.62 C373692703 Number of Inter-RAT(LTE->CDMA)Neighbour Cell Reported by UE


Definition

The counter is used to count the number of inter-RAT(LTE>CDMA)neighbour cell reported by UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When a CDMA neighbour cell reported by UE in the MeasurementReqport


for handover.

Explanation

The counter provides the number of CDMA neighbour cell reported by UE.

Updated

The counter is incremented by 1 when a CDMA neighbour cell reported by


UE in the MeasurementReqport for handover.

5-47
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.3.3.63 C373692704 Number of Inter-RAT(LTE->GSM)Neighbour Cell Reported by UE


Definition

The counter is used to count the number of inter-RAT(LTE->GSM)neighbour


cell reported by UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When a GSM neighbour cell reported by UE in the MeasurementReqport


for handover.

Explanation

The counter provides the number of GSM neighbour cell reported by UE.

Updated

The counter is incremented by 1 when a GSM neighbour cell reported by


UE in the MeasurementReqport for handover.

5.3.3.64 C373723013 Number of PCI Conflict(Cell Pair)


Definition

The counter is used to count the number of the service cell PCI same
to the neighbour cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB detects that the neighbour's PCI is the same to the
serving cell

Explanation

When the eNodeB detects that the neighbour's PCI is the same to the
serving cell ,it is added to the counter.

Updated

When the eNodeB detects that the neighbour's PCI is the same to the
serving cell ,the counter is incremented by 1.

5.3.3.65 C373723014 Number of PCI Confusion(Cell Pair)


Definition

The counter is used to count the number of detecting the two neighbour
cells PCI being the same.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation
5-48

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Sampling Point

When the eNodeB detects that the two neighbours' PCI is the same.

Explanation

When the eNodeB detects that the two neighbours' PCI is the same ,it is
added to the counter.

Updated

When the eNodeB detects that the two neighbours' PCI is the same,the
counter is incremented by 1.

5.4 X2 Self Configuration


5.4.1 Flow Charts and Sampling Points
No chart.

5.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373990480

Number of Getting Remote IP

C373990481

Number of Getted Remote IP

C373990482

Number of Successful Getted Remote IP

C373990483

Number of Not Enough X2 SCTP

C373990484

Number of No Neighbor X2 Self Delete

C373990485

Number of Link Error X2 Self Delete

C373990486

Number of X2 Self Setup Initiation

C373990487

Number of Successful X2 Self Setup

C373990488

Number of X2 Self Delete Initiation(Exclude Scan of the Invalid X2 SCTP)

10

C373990489

Number of Successful X2 Self Delete(Exclude Scan of the Invalid X2 SCTP)

11

C373990490

Number of Report Invalid X2 SCTP Self Delete

12

C373990491

Number of Successful Invalid X2 SCTP Self Delete

5.4.3 Counter Description


5.4.3.1 C373990480 Number of Getting Remote IP
Definition

The counter is used to count the number of getting remote IP.

Sampling Interval

Event triggered

Counter Type

Accumulative
5-49

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB initiates getting the remote IP.

Explanation

The eNodeB initiates getting the remote IP for X2 self setup,it is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB initiates getting the


remote IP.

5.4.3.2 C373990481 Number of Getted Remote IP


Definition

The counter is used to count the number of getted remote IP.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB getted the remote IP passively.

Explanation

The eNodeB gets the remote IP for X2 self setup initiated by the remote
eNodeB,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB getted the remote


IP passively.

5.4.3.3 C373990482 Number of Successful Getted Remote IP


Definition

The counter is used to count the number of successful getted remote IP.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB gets the remote IP successfully.

Explanation

The eNodeB gets the remote IP for X2 self successfully,it is added to the
counter.

Updated

The counter is incremented by 1 when the eNodeB gets the remote IP


successfully.

5-50
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

5.4.3.4 C373990483 Number of Not Enough X2 SCTP


Definition

The counter is used to count the number of not enough X2 SCTP.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB haven't enough X2 SCTP.

Explanation

The number of the X2 SCTP reached the maximum,it is added to the


counter.

Updated

The counter is incremented by 1 when the eNodeB haven't enough X2


SCTP.

5.4.3.5 C373990484 Number of No Neighbor X2 Self Delete


Definition

The counter is used to count the number of no neighbor X2 self delete.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB deletes the X2 SCTP due to no neighbourcell


relationship.

Explanation

The eNodeB deletes the X2 SCTP due to no neighbour cell relationship,it


is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB deletes the X2 SCTP


due to no neighboure cell relationship.

5.4.3.6 C373990485 Number of Link Error X2 Self Delete


Definition

The counter is used to count the number of link error X2 self delete.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB deletes the X2 SCTP due to link status error.

Explanation

The eNodeB deletes the X2 SCTP due to link status error,it is added to
the counter.
5-51

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB deletes the X2 SCTP


due to link status error.

5.4.3.7 C373990486 Number of X2 Self Setup Initiation


Definition

The counter is used to count the number of X2 self setup initiation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB initiates the X2 self setup.

Explanation

The eNodeB initiates the X2 self setup after configurating the relationship
with the neighbour cell,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB initiates the X2 self


setup.

5.4.3.8 C373990487 Number of Successful X2 Self Setup


Definition

The counter is used to count the number of successful X2 self setup.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB initiates the X2 self setup successfully.

Explanation

The eNodeB initiates the X2 self setup successfully,it is added to the


counter.

Updated

The counter is incremented by 1 when the eNodeB initiates the X2 self


setup successfully.

5.4.3.9 C373990488 Number of X2 Self Delete Initiation(Exclude Scan of the Invalid


X2 SCTP)
Definition

The counter is used to count the number of X2 self delete initiation(exclude


scan of the invalid X2 SCTP).

Sampling Interval

Event triggered

Counter Type

Accumulative
5-52

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 5 Statistics of SON

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB detects no relationship with neighbour cell,or content


the X2 self deletion condition.

Explanation

The eNodeB detects no relationship with neighbour cell,or content the X2


self deletion condition,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB detects no relationship


with neighbour cell,or content the X2 self deletion condition.

5.4.3.10 C373990489 Number of Successful X2 Self Delete(Exclude Scan of the Invalid


X2 SCTP)
Definition

The counter is used to count the number of successful X2 self


delete(exclude scan of the invalid X2 SCTP).

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB deletes the X2 SCTP successfully for non scanning of
the invalid X2 SCTP.

Explanation

The eNodeB deletes the X2 SCTP successfully for non scanning of the
invalid X2 SCTP,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB deletes the X2 SCTP


successfully for non scanning of the invalid X2 SCTP.

5.4.3.11 C373990490 Number of Report Invalid X2 SCTP Self Delete


Definition

The counter is used to count the number of report invalid X2 SCTP self
delete.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB detects the invalid X2 SCTP.

Explanation

The eNodeB detects the invalid X2 SCTP,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB detects the invalid


X2 SCTP.
5-53

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

5.4.3.12 C373990491 Number of Successful Invalid X2 SCTP Self Delete


Definition

The counter is used to count the number of successful invalid X2 SCTP


self delete.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the eNodeB deletes the X2 SCTP successfully for scanning of the
invalid X2 SCTP.

Explanation

The eNodeB deletes the X2 SCTP successfully for scanning of the invalid
X2 SCTP,it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB deletes the X2 SCTP


successfully for scanning of the invalid X2 SCTP.

5-54
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 6

Statistics of Cell Congestion


Table of Contents
Cell Congestion..........................................................................................................6-1

6.1 Cell Congestion


6.1.1 Flow Charts and Sampling Points
No chart.

6.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373404450

Number of Successful Triggered Cell DL Congestion

C373404451

Number of Triggered Cell DL Congestion Failure

C373404452

Number of Cell DL Load Balance Occurred

C373404453

Number of Cell DL Load Control Occurred

C373404454

Number of Cell UL Load Control Occurred

C373404455

Number of Cell Admission Failure due to Not Enough RRC Resource in


eNodeB

C373404456

Number of Cell Admission Failure due to Not Enough E-RAB Resource

C373404457

Number of Cell Admission Failure due to Not Enough DL PRB Resource

C373404458

Number of Cell Admission Failure due to Not Enough UL PRB Resource

10

C373404459

Number of Cell Admission Failure due to Not Enough Transport Resource

11

C373404460

Number of Cell Admission Failure due to Cell Block

12

C373404461

Number of Cell Admission Failure due to Not Enough DL Power

13

C373404462

Number of Cell Admission Failure due to PHY Resource Allocated Failure

14

C373404463

Number of Cell Admission Failure due to Other Reason

15

C373404464

Number of Cell Admission Failure due to Probability Refuse

16

C373404465

Number of Cell Admission Failure due to Not Enough PRB Resource in Load
Balance Inter Manufacturer

6-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
17

C373404466

Number of Successful Triggered Cell UL Congestion

18

C373404467

Number of Triggered Cell UL Congestion Failure

19

C373404468

Number of Cell UL Load Balance Occurred

20

C373404469

Number of Cell Admission Failure due to Not Enough CPU Resource

6.1.3 Counter Description


6.1.3.1 C373404450 Number of Successful Triggered Cell DL Congestion
Definition

The counter is used to count the number of admission success after


congestion control on the downlink.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs DL congestion,and then admit DL resource


successful.

Explanation

In the condition of opening "Switch for Congestion Control" , the eNodeB


triggers the DL congestion control process after detecting cell congestion,
then the DL resource admits successful, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB admits DL traffic


successful after DL congestion control.

6.1.3.2 C373404451 Number of Triggered Cell DL Congestion Failure


Definition

The counter is used to count the number of admission failure after


congestion control on the downlink.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs DL congestion,and then admission DL resource


failed.

6-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 6 Statistics of Cell Congestion

Explanation

In the condition of opening "Switch for Congestion Control" , the eNodeB


triggers the DL congestion control process after detecting cell congestion,
then the DL resource admits failed, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB admits DL traffic failed


after DL congestion control.

6.1.3.3 C373404452 Number of Cell DL Load Balance Occurred


Definition

The counter is used to count the number of cell DL load balance occurred.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB triggers the DL load balance.

Explanation

In the condition of opening "Load Management Switch of Load Balancing


Algorithm",the eNodeB measures the DL load of the serve cell and the
neighbor cell, when the eNodeB judges the cell needs to trigger DL load
balance process, it is added to the counter.

Updated

The counter is incremented by 1 when the cell triggers DL load balance.

6.1.3.4 C373404453 Number of Cell DL Load Control Occurred


Definition

The counter is used to count the number of cell DL load control occurred.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB triggers the DL load control.

Explanation

In the condition of opening "Load Management Switch of Load Control


Algorithm", when the eNodeB judges the cell needs to trigger DL load
control process, it is added to the counter.

Updated

The counter is incremented by 1 when the cell triggers DL load control.

6.1.3.5 C373404454 Number of Cell UL Load Control Occurred


Definition

The counter is used to count the number of cell UL load control occurred.

6-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB triggers the UL load control.

Explanation

In the condition of opening "Load Management Switch of Load Control


Algorithm",when the eNodeB judges the cell needs to trigger UL load
control process, it is added to the counter.

Updated

The counter is incremented by 1 when the cell triggers UL load control.

6.1.3.6 C373404455 Number of Cell Admission Failure due to Not Enough RRC
Resource in eNodeB
Definition

The counter is used to count the number of cell admission failure due to
not enough RRC resource in eNodeB.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new UE due to not enough RRC resource.

Explanation

The eNodeB reject the new UE when the current user number is greater
than the threshold of user number in a cell, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new UE


due to not enough RRC resource.

6.1.3.7 C373404456 Number of Cell Admission Failure due to Not Enough E-RAB
Resource
Definition

The counter is used to count the number of cell admission failure due to
not enough E-RAB resource.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new E-RAB due to not enough E-RAB
resource.

6-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 6 Statistics of Cell Congestion

Explanation

The eNodeB reject the new E-RAB when the current active E-RAB number
is greater than the threshold of active E-RAB number in a cell, it is added
to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new E-RAB
due to not enough E-RAB resource.

6.1.3.8 C373404457 Number of Cell Admission Failure due to Not Enough DL PRB
Resource
Definition

The counter is used to count the number of cell admission failure due
to not enough DL PRB resource.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new E-RAB due to not enough DL PRB
resource.

Explanation

The eNodeB reject the new E-RAB when the current DL PRB usage is
higher than the threshold, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new E-RAB
due to not enough DL PRB resource.

6.1.3.9 C373404458 Number of Cell Admission Failure due to Not Enough UL PRB
Resource
Definition

The counter is used to count the number of cell admission failure due
to not enough UL PRB resource.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new E-RAB due to not enough UL PRB
resource.

Explanation

The eNodeB reject the new E-RAB when the current UL PRB usage is
higher than the threshold, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new E-RAB
due to not enough UL PRB resource.

6-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

6.1.3.10 C373404459 Number of Cell Admission Failure due to Not Enough Transport
Resource
Definition

The counter is used to count the number of cell admission failure due
to not enough transport resource.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new E-RAB due to not enough transport
resource.

Explanation

The eNodeB reject the new E-RAB when the transport resource is not
enough, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new E-RAB
due to not enough transport resource.

6.1.3.11 C373404460 Number of Cell Admission Failure due to Cell Block


Definition

The counter is used to count the number of cell admission failure due
to cell block.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new UE due to cell block.

Explanation

The eNodeB reject the new UE due to cell block, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new UE


due to cell block.

6.1.3.12 C373404461 Number of Cell Admission Failure due to Not Enough DL Power
Definition

The counter is used to count the number of cell admission failure due to
not enough DL power.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell
6-6

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 6 Statistics of Cell Congestion

Sampling Point

When the eNodeB reject the new E-RAB due to not enough DL power
resource.

Explanation

The eNodeB reject the new E-RAB when the DL power resource is not
enough, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new E-RAB
due to not enough DL power resource.

6.1.3.13 C373404462 Number of Cell Admission Failure due to PHY Resource Allocated
Failure
Definition

The counter is used to count the number of cell admission failure due
to PHY resource allocated failure.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new UE or new E-RAB due to PHY resource
allocated failure.

Explanation

The eNodeB reject the new UE or new E-RAB when the PHY resource
allocated failure, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new UE or


new E-RAB due to PHY resource allocated failure.

6.1.3.14 C373404463 Number of Cell Admission Failure due to Other Reason


Definition

The counter is used to count the number of cell admission failure due
to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new UE or new E-RAB due to other reason.

Explanation

The eNodeB reject the new UE or new E-RAB due to other reason, it is
added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new UE or


new E-RAB due to other reason.

6-7
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

6.1.3.15 C373404464 Number of Cell Admission Failure due to Probability Refuse


Definition

The counter is used to count the number of cell admission failure due
to probability refuse.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new UE due to probability refuse.

Explanation

The eNodeB reject the new UE when the probability refuse, it is added to
the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new UE due
to probability refuse.

6.1.3.16 C373404465 Number of Cell Admission Failure due to Not Enough PRB
Resource in Load Balance Inter Manufacturer
Definition

The counter is used to count the number of cell admission failure due to
not enough PRB resource in load balance inter manufacturer.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new E-RAB due to not enough PRB resource
in load balance inter manufacturer resource.

Explanation

The eNodeB reject the new E-RAB when the PRB resource in load balance
inter manufacturer resource is not enough, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new E-RAB
due to not enough PRB resource in load balance inter manufacturer
resource.

6.1.3.17 C373404466 Number of Successful Triggered Cell UL Congestion


Definition

The counter is used to count the number of admission success after


congestion control on the uplink

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
6-8

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 6 Statistics of Cell Congestion

Measurement Object

Cell

Sampling Point

When the eNodeB occurs UL congestion, and then admit UL resource


successful.

Explanation

In the condition of opening "Switch for Congestion Control" , the eNodeB


triggers the UL congestion control process after detecting cell congestion,
then the UL resource admits successful, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB admits UL traffic


successful after UL congestion control.

6.1.3.18 C373404467 Number of Triggered Cell UL Congestion Failure


Definition

The counter is used to count the number of admission failure after


congestion control on the uplink

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs UL congestion, and then admission UL resource


failed.

Explanation

In the condition of opening "Switch for Congestion Control" , the eNodeB


triggers the UL congestion control process after detecting cell congestion,
then the UL resource admits failed, it is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB admits UL traffic failed


after UL congestion control.

6.1.3.19 C373404468 Number of Cell UL Load Balance Occurred


Definition

The counter is used to count the number of cell UL load balance occurred

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB triggers the UL load banlance.

Explanation

In the condition of opening "Load Management Switch of Load Balancing


Algorithm",the eNodeB measures the UL load of the serve cell and the
neighbor cell, when the eNodeB judges the cell needs to trigger UL load
balance process, it is added to the counter.
6-9

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the cell triggers UL load banlance.

6.1.3.20 C373404469 Number of Cell Admission Failure due to Not Enough CPU
Resource
Definition

The counter is used to count the number of cell admission failure due to
not enough CPU resource.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB reject the new UE or new E-RAB due to not enough
CPU resource.

Explanation

The eNodeB reject the new UE or new E-RAB when the current CPU
usage of CC board is greater than the threshold of CPU usage, it is added
to the counter.

Updated

The counter is incremented by 1 when the eNodeB reject the new UE or


new E-RAB due to not enough CPU resource.

6-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 7

Statistics of Service Time


Table of Contents
Cell Service Time .......................................................................................................7-1

7.1 Cell Service Time


7.1.1 Flow Charts and Sampling Points
No chart.

7.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373230700

Cell Service Time

C373230701

Cell Unavailable Time due to Cell Block

C373230702

Cell Unavailable Time due to S1 Link Breakdown

C373230703

Cell Unavailable Time due to BBU Abnormal

C373230704

Cell Unavailable Time due to RRU Abnormal

C373230705

Cell Unavailable Time due to Cell Config or Check

7.1.3 Counter Description


7.1.3.1 C373230700 Cell Service Time
Definition

The counter is used to count the time the cell has been available.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Measurement Object

Cell

Sampling Point

The eNodeB reports the collecting service time of cell at sampling time.

7-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB successfully setup a cell, record the start time. When
the eNodeB delete a cell due to some reasons, record the end time.The
cell service time is equal to the interval from the start time to the end time.

Updated

The counter is incremented by the cell service time at measurement period.

7.1.3.2 C373230701 Cell Unavailable Time due to Cell Block


Definition

The counter is used to count the time the cell has been unavailable for
cell block.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Measurement Object

Cell

Sampling Point

The eNodeB reports the collecting unavailable time of cell due to cell block
at sampling time.

Explanation

When the eNodeB receives the CellBlockCommand from the OMC, record
the start time. When the eNodeB receives the CellUnblockCommand from
the OMC, record the end time.
The cell unavailable time due to cell block time is equal to the interval
from the start time to the end time.

Updated

The counter is incremented by the cell unavailable time due to cell block at
per measurement period.

7.1.3.3 C373230702 Cell Unavailable Time due to S1 Link Breakdown


Definition

The counter is used to count the time the cell has been unavailable for
S1 link fault.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Measurement Object

Cell

Sampling Point

The eNodeB reports the collecting unavailable time of cell due to S1 link
fault at sampling time.

Explanation

When the eNodeB detects S1 link fault, record the start time. When the
eNodeB detects S1 link normal, record the end time.
The cell unavailable time due to s1 link fault is equal to the interval from
the start time to the end time.

7-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 7 Statistics of Service Time

Updated

The counter is incremented by the cell unavailable time due to S1 link


fault at per measurement period.

7.1.3.4 C373230703 Cell Unavailable Time due to BBU Abnormal


Definition

The counter is used to count the time the cell has been unavailable for
BBU abnormal.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Measurement Object

Cell

Sampling Point

The eNodeB reports the collecting unavailable time of cell due to BBU
abnormal at sampling time.

Explanation

When the eNodeB detects BBU abnormal, record the start time. When the
eNodeB detects BBU normal, record the end time.
The cell unavailable time due to BBU abnormal is equal to the interval
from the start time to the end time.

Updated

The counter is incremented by the cell unavailable time due to BBU


abnormal at per measurement period.

7.1.3.5 C373230704 Cell Unavailable Time due to RRU Abnormal


Definition

The counter is used to count the time the cell has been unavailable for
RRU abnormal.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Measurement Object

Cell

Sampling Point

The eNodeB reports the collecting unavailable time of cell due to RRU
abnormal at sampling time.

Explanation

When the eNodeB detects RRU abnormal, record the start time. When the
eNodeB detects RRU normal, record the end time.
The cell unavailable time due to RRU abnormal is equal to the interval
from the start time to the end time.

Updated

The counter is incremented by the cell unavailable time due to RRU


abnormal at per measurement period.

7-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

7.1.3.6 C373230705 Cell Unavailable Time due to Cell Config or Check


Definition

The counter is used to count the time the cell has been unavailable for
cell configuration or other reason.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Measurement Object

Cell

Sampling Point

The eNodeB reports the collecting unavailable time of cell due to cell
configuration at sampling time.

Explanation

When the eNodeB start to config a cell, record the start time. When the
eNodeB successfully config a cell, record the end time.
The cell unavailable time due to cell configuration is equal to the interval
from the start time to the end time.

Updated

The counter is incremented by the cell unavailable time due to cell


configuration at per measurement period.

7-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 8

Statistics of Redirection
Table of Contents
LTE-UTRAN Redirection ............................................................................................8-1
LTE-CDMA Redirection ..............................................................................................8-4
LTE-GSM Redirection.................................................................................................8-7

8.1 LTE-UTRAN Redirection


8.1.1 Flow Charts and Sampling Points
Figure 8-1 LTE-UTRAN Redirection

Sampling Point 1: The EUTRAN sends the RRC CONNECTION RELEASE message
to the UE.

8.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373576607

Number of Redirection Requests from LTE to UTRAN(CSFB)

C373576608

Number of Redirection Requests from LTE to UTRAN(Due to A2 event)

C373576609

Number of Redirection Requests from LTE to UTRAN(Due to Cell Block)

C373576610

Number of Redirection Requests from LTE to UTRAN(Due to B2 event)

C373576611

Number of Redirection Requests from LTE to UTRAN(Due to Energy Saving)

8-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

8.1.3 Counter Description


8.1.3.1 C373576607 Number of Redirection Requests from LTE to UTRAN(CSFB)
Definition

The counter is used to count the number of Redirection requests from


LTE to UTRAN for CSFB reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for CSFB reason in which the UTRAN redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


UTRAN for CSFB reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for CSFB reason in which the
UTRAN redirection information is included.

8.1.3.2 C373576608 Number of Redirection Requests from LTE to UTRAN(Due to A2


event)
Definition

The counter is used to count the number of Redirection requests from


LTE to UTRAN for A2 event reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for A2 event in which the UTRAN redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


UTRAN for A2 event reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for A2 event in which the
UTRAN redirection information is included.

8-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 8 Statistics of Redirection

8.1.3.3 C373576609 Number of Redirection Requests from LTE to UTRAN(Due to Cell


Block)
Definition

The counter is used to count the number of Redirection requests from


LTE to UTRAN for cell block reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE for block cell reason in which the UTRAN redirection information is
included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


UTRAN for cell block reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for block cell reason in which
the UTRAN redirection information is included.

8.1.3.4 C373576610 Number of Redirection Requests from LTE to UTRAN(Due to B2


event)
Definition

The counter is used to count the number of Redirection requests from


LTE to UTRAN for B2 event reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for B2 event in which the UTRAN redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


UTRAN for B2 event reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for B2 event in which the
UTRAN redirection information is included.

8-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

8.1.3.5 C373576611 Number of Redirection Requests from LTE to UTRAN(Due to


Energy Saving)
Definition

The counter is used to count the number of Redirection requests from


LTE to UTRAN for saving energy.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for saving energy in which the UTRAN redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


UTRAN for saving energy reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for saving energy in which
the UTRAN redirection information is included.

8.2 LTE-CDMA Redirection


8.2.1 Flow Charts and Sampling Points
Figure 8-2 LTE-CDMA Redirection

Sampling Point 1: The EUTRAN sends the RRC CONNECTION RELEASE message
to the UE.

8-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 8 Statistics of Redirection

8.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373576614

Number of Redirection Requests from LTE to CDMA2000(CSFB)

C373576615

Number of Redirection Requests from LTE to CDMA2000(Due to A2 event)

C373576616

Number of Redirection Requests from LTE to CDMA2000(Due to Cell Block)

C373576617

Number of Redirection Requests from LTE to CDMA2000(Due to B2 event)

C373576618

Number of Redirection Requests from LTE to CDMA2000(Due to Energy


Saving)

8.2.3 Counter Description


8.2.3.1 C373576614 Number of Redirection Requests from LTE to CDMA2000(CSFB)
Definition

The counter is used to count the number of Redirection requests from


LTE to CDMA2000 for CSFB reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE for CSFB reason in which the CDMA2000 redirection information
is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


CDMA2000 for CSFB reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for CSFB reason in which the
CDMA2000 redirection information is included.

8.2.3.2 C373576615 Number of Redirection Requests from LTE to CDMA2000(Due


to A2 event)
Definition

The counter is used to count the number of Redirection requests from LTE
to CDMA2000 for A2 event reason.

Sampling Interval

Event triggered

Counter Type

Accumulative
8-5

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for A2 event in which the CDMA2000 redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


CDMA2000 for A2 event reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for A2 event in which the
CDMA2000 redirection information is included.

8.2.3.3 C373576616 Number of Redirection Requests from LTE to CDMA2000(Due


to Cell Block)
Definition

The counter is used to count the number of Redirection requests from LTE
to CDMA2000 for cell block reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE for block cell reason in which the CDMA2000 redirection information
is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


CDMA2000 for cell block reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for block cell reason in which
the CDMA2000 redirection information is included.

8.2.3.4 C373576617 Number of Redirection Requests from LTE to CDMA2000(Due


to B2 event)
Definition

The counter is used to count the number of Redirection requests from LTE
to CDMA2000 for B2 event reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
8-6

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 8 Statistics of Redirection

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for B2 event in which the CDMA2000 redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


CDMA2000 for B2 event reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for B2 event in which the
CDMA2000 redirection information is included.

8.2.3.5 C373576618 Number of Redirection Requests from LTE to CDMA2000(Due


to Energy Saving)
Definition

The counter is used to count the number of Redirection requests from LTE
to CDMA2000 for saving energy.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the


UE for saving energy in which the CDMA2000 redirection information is
included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


CDMA2000 for saving energy reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for saving energy in which
the CDMA2000 redirection information is included.

8.3 LTE-GSM Redirection


8.3.1 Flow Charts and Sampling Points

8-7
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 8-3 LTE-GSM Redirection

Sampling Point 1: The EUTRAN sends the RRC CONNECTION RELEASE message
to the UE.

8.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373576600

Number of Redirection Requests from LTE to GSM(CSFB)

C373576601

Number of Redirection Requests from LTE to GSM(Due to A2 event)

C373576602

Number of Redirection Requests from LTE to GSM(Due to Cell Block)

C373576603

Number of Redirection Requests from LTE to GSM(Due to B2 event)

C373576604

Number of Redirection Requests from LTE to GSM(Due to Energy Saving)

8.3.3 Counter Description


8.3.3.1 C373576600 Number of Redirection Requests from LTE to GSM(CSFB)
Definition

The counter is used to count the number of Redirection requests from LTE
to GSM for CSFB reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for CSFB reason in which the GSM redirection information is included.
Sampling Point 1

Explanation

The counter provides the the number of Redirection requests from LTE
to GSM for CSFB reason.

8-8
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 8 Statistics of Redirection

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for CSFB reason in which the
GSM redirection information is included.

8.3.3.2 C373576601 Number of Redirection Requests from LTE to GSM(Due to A2


event)
Definition

The counter is used to count the number of Redirection requests from


LTE to GSM for A2 event reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for A2 event in which the GSM redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


GSM for A2 event reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for A2 event in which the
GSM redirection information is included.

8.3.3.3 C373576602 Number of Redirection Requests from LTE to GSM(Due to Cell


Block)
Definition

The counter is used to count the number of Redirection requests from


LTE to GSM for cell block reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for block cell reason in which the GSM redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


GSM for cell block reason.

8-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for block cell reason in which
the GSM redirection information is included.

8.3.3.4 C373576603 Number of Redirection Requests from LTE to GSM(Due to B2


event)
Definition

The counter is used to count the number of Redirection requests from


LTE to GSM for B2 event reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for B2 event in which the GSM redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


GSM for B2 event reason.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for B2 event in which the
GSM redirection information is included.

8.3.3.5 C373576604 Number of Redirection Requests from LTE to GSM(Due to Energy


Saving)
Definition

The counter is used to count the number of Redirection requests from LTE
to GSM for saving energy.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionRelease message to the UE


for saving energy in which the GSM redirection information is included.
Sampling Point 1

Explanation

The counter provides the number of Redirection requests from LTE to


GSM for saving energy reason.

8-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 8 Statistics of Redirection

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionRelease message to the UE for saving energy in which
the GSM redirection information is included.

8-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

8-12
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9

Statistics of Handover
Table of Contents
Intra-Rat Intra-Freq Handover on Cell.........................................................................9-2
Intra-Rat Inter-Freq Handover on Cell.......................................................................9-38
Inter-Rat Handover on Cell .......................................................................................9-75
Handover per Handover Cause on Cell .................................................................. 9-110
Intra-Rat Intra-Freq Handover on EUtranRelation...................................................9-137
Intra-Rat Inter-Freq Handover on EUtranRelation...................................................9-173
Inter-Rat Handover on EUtranRelation ...................................................................9-210
SRVCC Handover ..................................................................................................9-245
RSRP and RSRQ ..................................................................................................9-250
Handover Time.......................................................................................................9-281
DRX Handover .......................................................................................................9-284
GAP Handover .......................................................................................................9-289

9-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.1 Intra-Rat Intra-Freq Handover on Cell


9.1.1 Intra-eNB Intra-Freq Handover on Cell
9.1.1.1 Flow Charts and Sampling Points
Figure 9-1 Intra-eNB Handover

l
l
l
l

l
l

Sampling Point 1: The eNodeB receives the MeasurementReport message from UE.
Sampling Point 2: The eNodeB sends the RRCConnectionReconfiguration message
to UE.
Sampling Point 3: The handover execution process.
Sampling
Point
4:
The
eNodeB
receives
the
RRCConnectionReconfigurationComplete
message
from
UE
indicating
handover successfully.
Sampling
Point
5:
The
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling
Point
6:
The
eNodeB
receives
the
RRCConnectionReestablishmentRequest
message
from
UE
during
intra-eNB handover.

9-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.1.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373250900

Number of Successful Outgoing Intra-eNB Intra-freq Handover Preparation

C373250901

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to Re-estabilshment to Source eNodeB

C373250902

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to Dest Preparation Failure

C373250903

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to Other Reason

C373250940

Number of Successful Incoming Intra-eNB Intra-freq Handover Preparation

C373250941

Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due


to Resource Allocation Fail

C373250942

Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due


to Dest Occur Reestblishment

C373250943

Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due


to Other Reason

C373250980

Number of Successful Outgoing Intra-eNB Intra-freq Handover Execution

10

C373250981

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to


Re-estabilshment to Source eNodeB

11

C373250982

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to


Dest Occur Reestblishment

12

C373250983

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due


to Other Cause

13

C373250984

Number of Successful Incoming Intra-eNB Intra-freq Handover Execution

14

C373250985

Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due


to RRC ReconfigComplete Timeout

15

C373250986

Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to


Dest Occur Reestblishment

16

C373250987

Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due


to Other Cause

17

C373250988

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to User Inactivity

18

C373250989

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to


Waiting Reconfiguration Complete timeout

9-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.1.1.3 Counter Description


9.1.1.3.1 C373250900 Number of Successful Outgoing Intra-eNB Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing intra-eNB


intra-freq handovers preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


the UE.
Sampling Point 2

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing intra-eNB handover. Each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the RRC


Connection Reconfiguration message to the UE.

9.1.1.3.2 C373250901 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover preparation failures for UE reback to source cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.
Sampling Point 6

Explanation

The source cell has received the RRCConnectionReestablishmentRequest


message from the UE during the preparation of resources in target cell.
The source reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB receives the RRC


Connection Reestablishment Request message from UE in source cell.

9-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.1.1.3.3 C373250902 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to Dest
Preparation Failure
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover preparation failures due to target cell preparation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover preparation failures in target cell.

Explanation

Because the target cell has no enough resources, the source cell reports
the handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures in target cell.

9.1.1.3.4 C373250903 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in source cell.

Explanation

Because the source cell occurs other failure during handover preparation,
it reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in source cell.

9.1.1.3.5 C373250940 Number of Successful Incoming Intra-eNB Intra-freq Handover Preparation


Definition

The counter is used to count the number of successful incoming Intra-eNB


Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from UE in target cell.
Sampling Point 4

Explanation

The targe cell has an successful preparation of resources indicating a


successful incoming intra-eNB handover.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from UE in target cell.

9.1.1.3.6 C373250941 Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due to Resource
Allocation Fail
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the admission failures in target cell.

Explanation

The targe cell in eNB has an preparation failures of resources indicating a


incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs the admission


failures in target cell.

9.1.1.3.7 C373250942 Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due to Dest Occur
Reestblishment
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover preparation failures due to destination occuring reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The targe cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover preparation indicating a
incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.1.1.3.8 C373250943 Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in target cell.

Explanation

The targe cell in eNB occurs other failures during handover preparation
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in target cell.

9.1.1.3.9 C373250980 Number of Successful Outgoing Intra-eNB Intra-freq Handover Execution


Definition

The counter is used to count the number of successful outgoing Intra-eNB


Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE in target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from the UE in target
cell.

9.1.1.3.10 C373250981 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to UE reback source cell.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-7

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.

Explanation

The source cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution indicating a
outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9.1.1.3.11 C373250982 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to Dest Occur
Reestblishment
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to destination occuring reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the source
report handover failure indicating a outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.1.1.3.12 C373250983 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in source cell.

Explanation

The source cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.
9-8

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in source cell.

9.1.1.3.13 C373250984 Number of Successful Incoming Intra-eNB Intra-freq Handover Execution


Definition

The counter is used to count the number of successful Incoming Intra-eNB


Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE in target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter in target cell.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from the UE in target
cell.

9.1.1.3.14 C373250985 Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to RRC
ReconfigComplete Timeout
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

Explanation

After successful the preparation of resources in target cell,the timer of


monitoring RRCConnectionReconfigurationComplete message expires
during handover execution.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.1.1.3.15 C373250986 Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to Dest Occur
Reestblishment
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to destination occuring reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the target
report handover failure indicating a incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.1.1.3.16 C373250987 Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in target cell.

Explanation

The targe cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in target cell.

9.1.1.3.17 C373250988 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to User Inactivity
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

Cell

Sampling Point

The eNodeB detects that the UE's state is "inactive" in source cell during
handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover, the source cell detects the user's state inactive
then trigger UE release.

Updated

The counter is incremented by 1 when UE's state is "inactive" detected by


the eNodeB in source cell during handover preparation.

9.1.1.3.18 C373250989 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to Waiting
Reconfiguration Complete timeout
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfiguration


Complete message expires in target cell.
Sampling Point 5.

Explanation

After successful the preparation of resources in target cell during handover


execution,the timer of monitoring the RRCConnectionReconfigurationComplete message expires.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfiguration Complete message expires in target cell.

9.1.2 Inter-eNB X2 Intra-Freq Handover on Cell


9.1.2.1 Flow Charts and Sampling Points

9-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 9-2 X2 Handover(1)

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequest message to the
target eNodeB.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the source eNodeB.
Sampling Point 3: The source eNodeB receives the HandoverRequestAcknowledge
message from the target eNodeB.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to the source eNodeB.
Sampling
Point
5:
The
source
eNodeB
occurs
timeout
for
HandoverRequestAcknowledge message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the target eNodeB.
Sampling Point 7: The target eNodeB sends the HandoverPreprationFailure message
to the source eNodeB.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
9-12

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l
l
l
l
l

Sampling
Point
9:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
10:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 11: The target eNodeB sends the PathSwitchRequest message to
MME.
Sampling Point 12: The target eNodeB receives the PathSwitchAck message from
MME.
Sampling Point 13: The target eNodeB receives the PathSwitchFailure message from
MME.
Sampling Point 14: The target eNodeB occurs timeout for PathSwitchAck message.
Sampling Point 15: The target eNodeB sends the UEContextRelease message to the
source eNodeB.
Sampling Point 16: The source eNodeB receives the UEContextRelease message
from the target the eNodeB.
Sampling Point 17: The source eNodeB occurs timeout for UEContextRelease
message.

Figure 9-3 X2 Handover(2)

Sampling
Point
20:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB X2 handover.

the
during

9-13
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.1.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373261200

Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover


Preparation

C373261201

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to HO Request Ack Timeout

C373261202

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Dest Preparation Failure

C373261203

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Other Reason

C373261204

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373261240

Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover


Preparation

C373261241

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Resource Allocation Fail

C373261242

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Source Cancle HO

C373261243

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Other Reason

10

C373261280

Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover


Execution

11

C373261281

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373261282

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373261283

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Other Cause

14

C373261284

Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover


Execution

15

C373261285

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

16

C373261286

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Path Switch Failure

17

C373261287

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Other Cause

9-14
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
18

C373261288

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Source Cancel HO

19

C373261289

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to User Inactivity

20

C373261290

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

21

C373261291

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9.1.2.3 Counter Description


9.1.2.3.1 C373261200 Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 8

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the X2 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.1.2.3.2 C373261201 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
HO Request Ack Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to handover request ack
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-15

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverRequestAck


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequst message from the


source eNodeB to the target eNodeB, the timer of monitoring the
HandoverRequestAck message expires. Then the source sends the
HandoverCancel message to the target eNodeB. It indicates the handover
fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverRequestAck message expires.

9.1.2.3.3 C373261202 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failure due to target cell preparation failure.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the target eNodeB.
Sampling Point 6

Explanation

After transmission of the HandoverRequest message from the


source eNodeB to the target eNodeB, the source receives the
HandoverPreparationFailure message from the target eNodeB. It indicates
the handover has failed.Each HandoverPreparationFailure message
received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the target eNodeB.

9.1.2.3.4 C373261203 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-16

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source occurs other failures. Then the
source send HandoverCancel message to the target eNodeB. It indicates
the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.1.2.3.5 C373261204 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source eNodeB receives the RRC
CONNECTION REESTABLISHMENT REQUEST message from the UE. It
indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.1.2.3.6 C373261240 Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via X2) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the source eNodeB.
Sampling Point 4
9-17

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the source eNodeB indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the source eNodeB.

9.1.2.3.7 C373261241 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends Handover Preparation failure message to


the source eNodeB due to admission failures.
Sampling Point 7

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
has no enough resource then sends the HANDOVER PREPARATION
FAILURE message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


Preparation failure message to the source eNodeB due to admission
failures.

9.1.2.3.8 C373261242 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Source Cancle HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Intra-freq handover preparation failures due to source
cancel handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

9-18
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the HANDOVER CANCEL message from the source eNodeB
indicating handover failure.Each the HANDOVER CANCEL message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9.1.2.3.9 C373261243 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
occur other failures then sends the HANDOVER PREPARATION FAILURE
message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.1.2.3.10 C373261280 Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UE Context Release message


from the target eNodeB.
Sampling Point 16

Explanation

When eNodeB receives a X2AP message UE CONTEXT RELEASE sent


from the target eNodeB to the source eNodeB, it indicates a successful
handover over the X2. Each UE CONTEXT RELEASE message received
is added to the counter.
9-19

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB receives the UE


Context Release message from the target eNodeB.

9.1.2.3.11 C373261281 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover execution failures due to reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 20

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by the


source eNodeB from the UE during handover, the HANDOVER CANCEL
message is sent to by the source eNodeB to the target eNodeB. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.1.2.3.12 C373261282 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover execution failures due to the UE Context release
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 17

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the timer of monitoring the message
expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.
9-20

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.1.2.3.13 C373261283 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the other reason occurs.Then the
source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.1.2.3.14 C373261284 Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via X2) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE message to


the source eNodeB.
Sampling Point 15

Explanation

Transmission of a X2AP message UE CONTEXT RELEASE sent from


the target eNodeB to the source eNodeB, indicating a successful IRAT
handover. Each UE CONTEXT RELEASE message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE message to the source eNodeB.

9.1.2.3.15 C373261285 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover execution failures due to RRC reconfig complete
timeout.

9-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 10

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the timer
of monitoring RRCConnectionReconfigurationComplete message
expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.1.2.3.16 C373261286 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Path Switch Failure
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the PathSwitchRequestFailure message


or the timer of waiting for the PathSwitchACK message expires.
Sampling Point 13, Sampling Point 14

Explanation

After transmission of PATH SWITCH REQUEST message from target eNB


to the MME,the target receives the PATH SWITCH REQUEST FAILURE
message from the MME indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE message is added to the
counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


the PathSwitchRequestFailure message or the timer of waiting for the
PathSwitchACK message expires.

9.1.2.3.17 C373261287 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered
9-22

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target occur
other failures then trigger UE release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.1.2.3.18 C373261288 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter counts the number of failed intra-frequency incoming


handovers on the X2 interfaces between ENBs because the handover is
canceled by the source side.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the Handover Cancel message from
the source eNodeB.

Explanation

After transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the source eNodeB to the target eNodeB, the
source eNodeB receives the RRCConnectionReestablishmentRequest
message from the UE. The HANDOVER CANCEL message is sent to by
the source eNodeB to the target eNodeB.

Updated

The counter is incremented by 1 when the target eNodeB receives the


Handover Cancel message from the source eNodeB.

9.1.2.3.19 C373261289 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-23
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the source eNodeB to the target eNodeB. Each the
condition is added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.1.2.3.20 C373261290 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Intra-freq handover preparation failures due to RRC
connection reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE during handover preparation.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the RRCConnectionReestablishmentRequest message from the
UE then sends the HANDOVER FAILURE message to the source eNodeB
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE during
handover preparation.

9.1.2.3.21 C373261291 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


X2) Intra-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-24
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE during handover execution.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNodeB to the source eNodeB,the target
receives the RRCConnectionReestablishmentRequest message from the
UE indicating the handover failure.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE during
handover execution.

9.1.3 Inter-eNB S1 Intra-Freq Handover on Cell


9.1.3.1 Flow Charts and Sampling Points
Figure 9-4 S1 Handover(1)

9-25
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l
l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

9-26
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Figure 9-5 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.1.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373271500

Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover


Preparation

C373271501

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to HO Command Timeout

C373271502

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Dest Preparation Failure

C373271503

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Other Reason

C373271504

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373271540

Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover


Preparation

C373271541

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Resource Allocation Fail

9-27
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
8

C373271542

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Source Cancel HO

C373271543

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Other Reason

10

C373271580

Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover


Execution

11

C373271581

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373271582

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373271583

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Other Cause

14

C373271584

Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover


Execution

15

C373271585

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

16

C373271586

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Source Cancel HO

17

C373271587

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Other Cause

18

C373271588

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to User Inactivity

19

C373271589

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

20

C373271590

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9.1.3.3 Counter Description


9.1.3.3.1 C373271500 Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-28
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 8

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the S1 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.1.3.3.2 C373271501 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to handover command timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source sends the HandoverCancel message
to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.1.3.3.3 C373271502 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell
9-29

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationFailures
message from the MME. It indicates the handover has failed.Each
HandoverPreparationFailures message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9.1.3.3.4 C373271503 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.1.3.3.5 C373271504 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

9-30
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source eNodeB receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE. It indicates the
handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.1.3.3.6 C373271540 Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via S1) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNB,the target sends the HANDOVER REQUEST ACKNOWLEDGE
message to the MME indicating the successful preparation of
resources.Each HANDOVER REQUEST ACKNOWLEDGE message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.1.3.3.7 C373271541 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

9-31
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.1.3.3.8 C373271542 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Source Cancel HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Intra-freq handover preparation failures due to source
cancle handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNB to request the preparation of resources,the target occur other
failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.1.3.3.9 C373271543 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNB to request the preparation of resources,the target occur other
failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.
9-32

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.1.3.3.10 C373271580 Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates
a successful handover over the S1. Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.1.3.3.11 C373271581 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover execution failures due to reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 15

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to MME by the source eNodeB. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9-33
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.1.3.3.12 C373271582 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover execution failures due to the UE Context release
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.1.3.3.13 C373271583 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.1.3.3.14 C373271584 Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via S1) Intra-freq handover execution.

Sampling Interval

Event triggered

9-34
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE COMMAND


message to MME.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE COMMAND message to MME.

9.1.3.3.15 C373271585 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover execution failures due to RRC reconfig complete
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.1.3.3.16 C373271586 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-35
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.1.3.3.17 C373271587 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.1.3.3.18 C373271588 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

9-36
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNB to the target eNB, the
source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.1.3.3.19 C373271589 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Intra-freq handover preparation failures due to
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the RRCConnectionReestablishmentRequest message from the UE then
sends the HANDOVER FAILURE message to the MME indicating the
handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.1.3.3.20 C373271590 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


S1) Intra-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

9-37
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the RRCConnectionReestablishmentRequest message from the UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.2 Intra-Rat Inter-Freq Handover on Cell


9.2.1 Intra-eNB Inter-Freq Handover on Cell
9.2.1.1 Flow Charts and Sampling Points
Figure 9-6 Intra-eNB Handover

l
l
l
l

Sampling Point 1: The eNodeB receives the MeasurementReport message from UE.
Sampling Point 2: The eNodeB sends the RRCConnectionReconfiguration message
to UE.
Sampling Point 3: The handover execution process.
Sampling
Point
4:
The
eNodeB
receives
the
RRCConnectionReconfigurationComplete
message
from
UE
indicating
handover successfully.
9-38

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l

Sampling
Point
5:
The
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling
Point
6:
The
eNodeB
receives
the
RRCConnectionReestablishmentRequest
message
from
UE
during
intra-eNB handover.

9.2.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373281800

Number of Successful Outgoing Intra-eNB Inter-freq Handover Preparation

C373281801

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to Re-estabilshment to Source eNodeB

C373281802

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to Dest Preparation Failure

C373281803

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to Other Reason

C373281840

Number of Successful Incoming Intra-eNB Inter-freq Handover Preparation

C373281841

Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due


to Resource Allocation Fail

C373281842

Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due


to Dst occur Re-establishment

C373281843

Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due


to Other Reason

C373281880

Number of Successful Outgoing Intra-eNB Inter-freq Handover Execution

10

C373281881

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to


Re-estabilshment to Source eNodeB

11

C373281882

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to


Dst occur Re-establishment

12

C373281883

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due


to Other Cause

13

C373281884

14

C373281885

Number of Successful Incoming Intra-eNB Inter-freq Handover Execution


Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout

15

C373281886

Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to


Dst occur Re-establishment

16

C373281887

Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due


to Other Cause

9-39
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
17

C373281888

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to User Inactivity

18

C373281889

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to


Waiting Reconfiguration Complete Timeout

9.2.1.3 Counter Description


9.2.1.3.1 C373281800 Number of Successful Outgoing Intra-eNB Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing Intra-eNB


Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


the UE.
Sampling Point 2

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing intra-eNB handover. Each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.2.1.3.2 C373281801 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover preparation failures due to the UE reback to source cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.
Sampling Point 6

9-40
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

The source cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during the preparation of resources in
target cell. The source reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9.2.1.3.3 C373281802 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to Dest
Preparation Failure
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover preparation failures due to target cell preparation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover preparation failures in target cell.

Explanation

Because the target cell in eNB has no enough resources, the source cell
reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures in target cell.

9.2.1.3.4 C373281803 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in source cell.

Explanation

Because the source cell in eNB occurs other failure during handover
preparation, it reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in source cell.

9.2.1.3.5 C373281840 Number of Successful Incoming Intra-eNB Inter-freq Handover Preparation


Definition

The counter is used to count the number of successful incoming Intra-eNB


Inter-freq handover preparation.

Sampling Interval

Event triggered
9-41

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from UE in target cell.
Sampling Point 4

Explanation

The targe cell in eNB has an successful preparation of resources indicating


a successful incoming intra-eNB handover.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from UE in target cell.

9.2.1.3.6 C373281841 Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due to Resource
Allocation Fail
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs the admission failures in target cell.

Explanation

The targe cell in eNB has an preparation failures of resources indicating a


incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs the admission


failures in target cell.

9.2.1.3.7 C373281842 Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due to Dst occur
Re-establishment
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover preparation failures due to destination occuring reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

9-42
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

The targe cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover preparation indicating a
incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.2.1.3.8 C373281843 Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in target cell.

Explanation

The targe cell in eNB occurs other failures during handover preparation
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in target cell.

9.2.1.3.9 C373281880 Number of Successful Outgoing Intra-eNB Inter-freq Handover Execution


Definition

The counter is used to count the number of successful outgoing Intra-eNB


Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE in target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from the UE in target
cell.

9-43
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.2.1.3.10 C373281881 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.

Explanation

The source cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution indicating a
outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9.2.1.3.11 C373281882 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to Dst occur
Re-establishment
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to destination occuring reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the source
report handover failure indicating a outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.2.1.3.12 C373281883 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-44

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in source cell.

Explanation

The source cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in source cell.

9.2.1.3.13 C373281884 Number of Successful Incoming Intra-eNB Inter-freq Handover Execution


Definition

The counter is used to count the number of successful Incoming Intra-eNB


Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE in target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter in target cell.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from the UE in target
cell.

9.2.1.3.14 C373281885 Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to RRC Reconfig
Complete Timeout
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to RRC reconfig complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

9-45
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After successful the preparation of resources in target cell,the timer of


monitoring RRCConnectionReconfigurationComplete message expires
during handover execution.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9.2.1.3.15 C373281886 Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to Dst occur
Re-establishment
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to destination occuring reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the target
report handover failure indicating a incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.2.1.3.16 C373281887 Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in target cell.

Explanation

The targe cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in target cell.

9-46
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.2.1.3.17 C373281888 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to User Inactivity
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The eNodeB detects that the UE's state is "inactive" in source cell during
handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover, the source cell detects the user inactive then
trigger UE release.

Updated

The counter is incremented by 1 when UE's state is "user inactive" in


source cell during handover preparation.

9.2.1.3.18 C373281889 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to Waiting
Reconfiguration Complete Timeout
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to RRC reconfig complete timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

Explanation

After successful the preparation of resources in target cell during handover


execution,the timer of monitoring RRCConnectionReconfigurationComplete
message expires.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9-47
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.2.2 Inter-eNB X2 Inter-Freq Handover on Cell


9.2.2.1 Flow Charts and Sampling Points
Figure 9-7 X2 Handover(1)

l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequest message to the
target eNodeB.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the source eNodeB.
Sampling Point 3: The source eNodeB receives the HandoverRequestAcknowledge
message from the target eNodeB.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to the source eNodeB.
Sampling
Point
5:
The
source
eNodeB
occurs
timeout
for
HandoverRequestAcknowledge message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the target eNodeB.
9-48

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l
l
l
l
l
l
l

Sampling Point 7: The target eNodeB sends the HandoverPreprationFailure message


to the source eNodeB.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
Sampling
Point
9:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
10:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 11: The target eNodeB sends the PathSwitchRequest message to
MME.
Sampling Point 12: The target eNodeB receives the PathSwitchAck message from
MME.
Sampling Point 13: The target eNodeB receives the PathSwitchFailure message from
MME.
Sampling Point 14: The target eNodeB occurs timeout for PathSwitchAck message.
Sampling Point 15: The target eNodeB sends the UEContextRelease message to the
source eNodeB.
Sampling Point 16: The source eNodeB receives the UEContextRelease message
from the target the eNodeB.
Sampling Point 17: The source eNodeB occurs timeout for UEContextRelease
message.

Figure 9-8 X2 Handover(2)

9-49
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling
Point
20:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB X2 handover.

the
during

9.2.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373292100

Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover


Preparation

C373292101

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to HO Request Ack Timeout

C373292102

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Dest Preparation Failure

C373292103

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Other Reason

C373292104

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373292140

Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover


Preparation

C373292141

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Resource Allocation Fail

C373292142

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Source Cancel HO

C373292143

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Other Reason

10

C373292180

Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover


Execution

11

C373292181

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373292182

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373292183

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Other Cause

14

C373292184

Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover


Execution

15

C373292185

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to RRC Reconfig Timeout

9-50
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
16

C373292186

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Path Switch Failure

17

C373292187

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Other Cause

18

C373292188

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Source Cancel HO

19

C373292189

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to User Inactivity

20

C373292190

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

21

C373292191

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9.2.2.3 Counter Description


9.2.2.3.1 C373292100 Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 8

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the X2 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9-51
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.2.2.3.2 C373292101 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
HO Request Ack Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to handover request ack
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverRequestAck


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequst message from the


source eNodeB to the target eNodeB, the timer of monitoring the
HandoverRequestAck message expires. Then the source sends the
HandoverCancel message to the target eNodeB. It indicates the handover
fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverRequestAck message expires.

9.2.2.3.3 C373292102 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the target eNodeB.
Sampling Point 6

Explanation

After transmission of the HandoverRequest message from the


source eNodeB to the target eNodeB, the source receives the
HandoverPreparationFailure message from the target eNodeB. It indicates
the handover has failed.Each HandoverPreparationFailure message
received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the target eNodeB.

9-52
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.2.2.3.4 C373292103 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source occurs other failures. Then the
source send HandoverCancel message to the target eNodeB. It indicates
the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.2.2.3.5 C373292104 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source eNodeB receives the RRC
CONNECTION REESTABLISHMENT REQUEST message from the UE. It
indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.2.2.3.6 C373292140 Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via X2) Inter-freq handover preparation.
9-53

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the source eNodeB.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the source eNodeB indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the source eNodeB.

9.2.2.3.7 C373292141 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends Handover Preparation failure message to


the source eNodeB due to admission failures.
Sampling Point 7

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
has no enough resource then sends the HANDOVER PREPARATION
FAILURE message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


Preparation failure message to the source eNodeB due to admission
failures.

9.2.2.3.8 C373292142 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Source Cancel HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Inter-freq handover preparation failures due to source
cancle handover.

9-54
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the HANDOVER CANCEL message from the source eNodeB
indicating handover failure.Each the HANDOVER CANCEL message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9.2.2.3.9 C373292143 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
occur other failures then sends the HANDOVER PREPARATION FAILURE
message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.2.2.3.10 C373292180 Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell
9-55

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the source eNodeB receives the UE Context Release message


from the target eNodeB.
Sampling Point 16

Explanation

When eNodeB receives a X2AP message UE CONTEXT RELEASE sent


from the target eNodeB to the source eNodeB, it indicates a successful
handover over the X2. Each UE CONTEXT RELEASE message received
is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the UE


Context Release message from the target eNodeB.

9.2.2.3.11 C373292181 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover execution failures due to reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 20

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by the


source eNodeB from the UE during handover, the HANDOVER CANCEL
message is sent to the target eNodeB by the source eNodeB. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.2.2.3.12 C373292182 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover execution failures due to the UE Context release
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-56
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 17

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the timer of monitoring the message
expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.2.2.3.13 C373292183 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the other reason occurs.Then the
source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.2.2.3.14 C373292184 Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via X2) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE message to


the source eNodeB.
Sampling Point 15

Explanation

Transmission of a X2AP message UE CONTEXT RELEASE sent from


target eNodeB to the source eNodeB, indicating a successful IRAT
handover. Each UE CONTEXT RELEASE message received is added to
the counter.
9-57

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE message to the source eNodeB.

9.2.2.3.15 C373292185 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
RRC Reconfig Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover execution failures due to RRC reconfig complete
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete expires.
Sampling Point 10

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the timer
of monitoring RRCConnectionReconfigurationComplete message
expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfiguration Complete message expires.

9.2.2.3.16 C373292186 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Path Switch Failure
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the PathSwitchRequestFailure message


or the timer of waiting for the PathSwitchACK message expires.
Sampling Point 13, Sampling Point 14

Explanation

After transmission of PATH SWITCH REQUEST message from target eNB


to the MME,the target receives the PATH SWITCH REQUEST FAILURE
message from the MME indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE message is added to the
counter.

9-58
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the target eNodeB receives


the PathSwitchRequestFailure message or the timer of waiting for the
PathSwitchACK message expires.

9.2.2.3.17 C373292187 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target occur
other failures then trigger UE release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.2.2.3.18 C373292188 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter counts the number of failed Inter-frequency outgoing


handovers on the X2 interfaces between ENBs because the handover is
canceled by the source side.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

Explanation

After transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the source eNodeB to the target eNodeB, the
source eNodeB receives the RRCConnectionReestablishmentRequest
message from the UE. The HANDOVER CANCEL message is sent to by
the source eNodeB to the target eNodeB.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9-59
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.2.2.3.19 C373292189 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The eNodeB detects that the UE's state is "inactive" in source eNodeB
during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the source eNodeB to the target eNodeB. Each the
condition is added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.2.2.3.20 C373292190 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Inter-freq handover preparation failures due to
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the RRCConnectionReestablishmentRequest message from the
UE then sends the HANDOVER FAILURE message to the source eNodeB
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9-60
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.2.2.3.21 C373292191 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


X2) Inter-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target
receives the RRCConnectionReestablishmentRequest message from the
UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.2.3 Inter-eNB S1 Inter-Freq Handover on Cell


9.2.3.1 Flow Charts and Sampling Points

9-61
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 9-9 S1 Handover(1)

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
9-62

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-10 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.2.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373302400

Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover


Preparation

C373302401

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to HO Command Timeout

9-63
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
3

C373302402

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Dest Preparation Failure

C373302403

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Other Reason

C373302404

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373302440

Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover


Preparation

C373302441

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Resource Allocation Fail

C373302442

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Source Cancel HO

C373302443

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Other Reason

10

C373302480

Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover


Execution

11

C373302481

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373302482

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373302483

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Other Cause

14

C373302484

Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover


Execution

15

C373302485

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

16

C373302486

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Source Cancel HO

17

C373302487

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Other Cause

18

C373302488

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to User Inactivity

19

C373302489

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

20

C373302490

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9-64
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.2.3.3 Counter Description


9.2.3.3.1 C373302400 Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 8

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the S1 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.2.3.3.2 C373302401 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to handover command timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source sends the HandoverCancel message
to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9-65
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.2.3.3.3 C373302402 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9.2.3.3.4 C373302403 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.2.3.3.5 C373302404 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered
9-66

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source eNodeB receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE. It indicates the
handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.2.3.3.6 C373302440 Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via S1) Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.2.3.3.7 C373302441 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-67

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.2.3.3.8 C373302442 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Source Cancel HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Inter-freq handover preparation failures due to source
cancle handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.2.3.3.9 C373302443 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-68
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.2.3.3.10 C373302480 Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates
a successful handover over the S1. Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.2.3.3.11 C373302481 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover execution failures due to source reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 15

9-69
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to MME by the source eNodeB. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.2.3.3.12 C373302482 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover execution failures due to the UE context release
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.2.3.3.13 C373302483 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.
9-70

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.2.3.3.14 C373302484 Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via S1) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE COMMAND


message to MME.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE COMMAND message to MME.

9.2.3.3.15 C373302485 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover execution failures due to RRC reconfig complete
timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9-71
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.2.3.3.16 C373302486 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.2.3.3.17 C373302487 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.2.3.3.18 C373302488 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered
9-72

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.2.3.3.19 C373302489 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Inter-freq handover preparation failures due to
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the RRCConnectionReestablishmentRequest message from the UE then
sends the HANDOVER FAILURE message to the MME indicating the
handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.2.3.3.20 C373302490 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


S1) Inter-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-73

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the RRCConnectionReestablishmentRequest message from the UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9-74
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.3 Inter-Rat Handover on Cell


9.3.1 LTE-UMTS Handover on Cell
9.3.1.1 Flow Charts and Sampling Points
Figure 9-11 Inter-RAT Handover

9-75
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.

9-76
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-12 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.3.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373312700

Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover


Preparation

C373312701

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation


Failure due to Resource Allocation Fail

9-77
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
3

C373312702

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation


Failure due to Source Cancel HO

C373312703

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation


Failure due to Other Reason

C373312704

Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover


Execution

C373312705

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure


due to RRC Reconfig Complete Timeout

C373312706

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure


due to Source Cancel HO

C373312707

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure


due to Other Cause

C373312708

Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover


Preparation

10

C373312709

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to HO Command Timeout

11

C373312710

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to Dst Preparation Failure

12

C373312711

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to Other Reason

13

C373312712

Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover


Execution

14

C373312713

Number of Outgoing Inter-RAT(LTE->UTRAN)Handover Execution Failure


due to Re-estabilshment to Source eNodeB

15

C373312714

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure


due to UE Context Release Timeout

16

C373312715

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure


due to Other Cause

17

C373312716

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to User Inactivity

9.3.1.3 Counter Description


9.3.1.3.1 C373312700 Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-RAT(UTRAN to LTE) Handover Preparation
9-78

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.3.1.3.2 C373312701 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Preparation failures due to resource allocation fail.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverFailure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverFailure message to the MME due to admission failures.

9.3.1.3.3 C373312702 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Preparation failures due to source cancel handover.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-79

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.3.1.3.4 C373312703 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.3.1.3.5 C373312704 Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover Execution


Definition

The counter is used to count the number of successful Incoming


Inter-RAT(UTRAN to LTE) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-80
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE COMMAND


message from UE.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE COMMAND message from UE.

9.3.1.3.6 C373312705 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure due to RRC
Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.3.1.3.7 C373312706 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Execution failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

9-81
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.3.1.3.8 C373312707 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Execution failures due to Other Cause.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.3.1.3.9 C373312708 Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to UTRAN) Handover Preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 3

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the eNodeB to the UTRAN,it indicates
the successful preparation of an outgoing inter-eNB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.
9-82

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.3.1.3.10 C373312709 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to HO Command Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source send HandoverCancel message to the
MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.3.1.3.11 C373312710 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due to
Dst Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to destination Preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationfailure
message from the MME. It indicates the handover has failed.Each
HandoverPreparationfailure message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.
9-83

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.3.1.3.12 C373312711 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.3.1.3.13 C373312712 Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover Execution


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to UTRAN) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to UTRAN). Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.3.1.3.14 C373312713 Number of Outgoing Inter-RAT(LTE->UTRAN)Handover Execution Failure due to


Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN)Handover Execution failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

9-84
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.3.1.3.15 C373312714 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.3.1.3.16 C373312715 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-85
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.3.1.3.17 C373312716 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The eNodeB detects that the UE's state is "inactive" in source eNodeB
during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.3.2 LTE-CDMA Handover on Cell


9.3.2.1 Flow Charts and Sampling Points

9-86
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Figure 9-13 Inter-RAT Handover

9-87
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.

9-88
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-14 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.3.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373323000

Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover


Preparation

C373323001

Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure


due to Resource Allocation Fail

9-89
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
3

C373323002

Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure


due to Source Cancel HO

C373323003

Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure


due to Other Reason

C373323004

Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover


Execution

C373323005

Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure


due to RRC Reconfig Complete Timeout

C373323006

Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure


due to Source Cancel HO

C373323007

Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure


due to Other Cause

C373323008

Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover


Preparation

10

C373323009

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to HO Command Timeout

11

C373323010

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to Dst Preparation Failure

12

C373323011

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to Other Reason

13

C373323012

Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover


Execution

14

C373323013

Number of Outgoing Inter-RAT(LTE->CDMA)Handover Execution Failure


due to Re-estabilshment to Source eNodeB

15

C373323014

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure


due to UE Context Release Timeout

16

C373323015

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure


due to Other Cause

17

C373323016

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to User Inactivity

9.3.2.3 Counter Description


9.3.2.3.1 C373323000 Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-RAT(GSM to LTE) Handover Preparation.
9-90

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.3.2.3.2 C373323001 Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to resource allocation fail.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.3.2.3.3 C373323002 Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-91

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.3.2.3.4 C373323003 Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.3.2.3.5 C373323004 Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover Execution


Definition

The counter is used to count the number of successful Incoming


Inter-RAT(GSM to LTE) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-92
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE COMMAND


message to MME.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE COMMAND message to MME.

9.3.2.3.6 C373323005 Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure due to RRC
Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.3.2.3.7 C373323006 Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

9-93
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.3.2.3.8 C373323007 Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Other Cause.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.3.2.3.9 C373323008 Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover Preparation


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to CDMA) Handover Preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 3

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the eNodeB to the CDMA,it indicates
the successful preparation of an outgoing inter-eNB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.
9-94

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.3.2.3.10 C373323009 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to HO Command Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source send HandoverCancel message to the
MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.3.2.3.11 C373323010 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to Dst
Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to destination Preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationfailure
message from the MME. It indicates the handover has failed.Each
HandoverPreparationfailure message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.
9-95

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.3.2.3.12 C373323011 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.3.2.3.13 C373323012 Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover Execution


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to CDMA) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to UTRAN). Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.3.2.3.14 C373323013 Number of Outgoing Inter-RAT(LTE->CDMA)Handover Execution Failure due to


Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA)Handover Execution failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

9-96
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.3.2.3.15 C373323014 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.3.2.3.16 C373323015 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-97
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.3.2.3.17 C373323016 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to
User Inactivity
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The eNodeB detects that the UE's state is "inactive" in source eNodeB
during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.3.3 LTE-GSM Handover on Cell


9.3.3.1 Flow Charts and Sampling Points

9-98
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Figure 9-15 Inter-RAT Handover

9-99
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.

9-100
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-16 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.3.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373333300

Number of Successful Incoming Inter-RAT(GSM to LTE) Handover


Preparation

C373333301

Number of Incoming Inter-RAT(GSM to LTE) Handover Preparation Failure


due to Resource Allocation Fail

9-101
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
3

C373333302

Number of Incoming Inter-RAT(GSM to LTE) Handover Preparation Failure


due to Source Cancel HO

C373333303

Number of Incoming Inter-RAT(GSM to LTE) Handover Preparation Failure


due to Other Reason

C373333304

Number of Successful Incoming Inter-RAT(GSM to LTE) Handover Execution

C373333305

Number of Incoming Inter-RAT(GSM to LTE) Handover Execution Failure


due to RRC Reconfig Complete Timeout

C373333306

Number of Incoming Inter-RAT(GSM to LTE) Handover Execution Failure


due to Path Source Cancel HO

C373333307

Number of Incoming Inter-RAT(GSM to LTE) Handover Execution Failure


due to Other Cause

C373333308

Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover


Preparation

10

C373333309

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to HO Command Timeout

11

C373333310

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to Destination Preparation Failure

12

C373333311

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to Other Reason

13

C373333312

Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover Execution

14

C373333313

Number of Outgoing Inter-RAT(LTE->GSM)Handover Execution Failure due


to Re-estabilshment to Source eNodeB

15

C373333314

Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure


due to UE Context Release Timeout

16

C373333315

Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure


due to Other Cause

17

C373333316

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to User Inactivity

9.3.3.3 Counter Description


9.3.3.3.1 C373333300 Number of Successful Incoming Inter-RAT(GSM to LTE) Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-RAT(GSM to LTE) Handover Preparation

Sampling Interval

Event triggered

9-102
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.3.3.3.2 C373333301 Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure due to Resource
Allocation Fail
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to resource allocation fail.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.3.3.3.3 C373333302 Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-103

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.3.3.3.4 C373333303 Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.3.3.3.5 C373333304 Number of Successful Incoming Inter-RAT(GSM- to LTE) Handover Execution


Definition

The counter is used to count the number of successful Incoming


Inter-RAT(GSM to LTE) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE COMMAND


to MME.
Sampling Point 12

9-104
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE COMMAND to MME.

9.3.3.3.6 C373333305 Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure due to RRC
Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.3.3.3.7 C373333306 Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure due to Path
Source Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.
9-105

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.3.3.3.8 C373333307 Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Other Cause.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.3.3.3.9 C373333308 Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover Preparation


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to GSM) Handover Preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 3

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the eNodeB to the GSM,it indicates the
successful preparation of an outgoing inter-eNB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9-106
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.3.3.3.10 C373333309 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to HO
Command Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Preparation failures due to HO Command Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source send HandoverCancel message to the
MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.3.3.3.11 C373333310 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to
Destination Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE


to GSM) Handover Preparation failures due to destination Preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationfailure
message from the MME. It indicates the handover has failed.Each
HandoverPreparationfailure message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9-107
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.3.3.3.12 C373333311 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.3.3.3.13 C373333312 Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover Execution


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to GSM) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to UTRAN). Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.3.3.3.14 C373333313 Number of Outgoing Inter-RAT(LTE->GSM)Handover Execution Failure due to


Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM)Handover Execution failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

9-108
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.3.3.3.15 C373333314 Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE


to GSM) Handover Execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.3.3.3.16 C373333315 Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-109
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.3.3.3.17 C373333316 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to User
Inactivity
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The eNodeB detects that the UE's state is "inactive" in source eNodeB
during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.4 Handover per Handover Cause on Cell


9.4.1 Handover Based on Covering
9.4.1.1 Flow Charts and Sampling Points
No chart.

9-110
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.4.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373485100

Number of Successful Outgoing Inter-Cell Intra-freq Handover Preparation


based Covering

C373485101

Number of Outgoing Inter-Cell Intra-freq Handover Preparation Failure


based Covering

C373485102

Number of Successful Outgoing Inter-Cell Intra-freq Handover Execution


based Covering

C373485103

Number of Outgoing Inter-Cell Intra-freq Handover Execution Failure based


Covering

C373485104

Number of Successful Outgoing Inter-Cell Inter-freq Handover Preparation


based Covering

C373485105

Number of Outgoing Inter-Cell Inter-freq Handover Preparation Failure


based Covering

C373485106

Number of Successful Outgoing Inter-Cell Inter-freq Handover Execution


based Covering

C373485107

Number of Outgoing Inter-Cell Inter-freq Handover Execution Failure based


Covering

9.4.1.3 Counter Description


9.4.1.3.1 C373485100 Number of Successful Outgoing Inter-Cell Intra-freq Handover Preparation based Covering
Definition

The counter is used to count the number of successful outgoing intra-freq


handovers preparation for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation completes. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNB handover, X2 interface handover, and S1
interface handover.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing inter-eNB handover. If the handover cause is coverage and
the handover type is intra-freq, each RRCConnectionReconfiguration
message transimtted is added to the counter.
9-111

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source cell handover preparation


completes.

9.4.1.3.2 C373485101 Number of Outgoing Inter-Cell Intra-freq Handover Preparation Failure based Covering
Definition

The counter is used to count the number of outgoing intra-freq handovers


preparation failures for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation fails. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNB handover, X2 interface handover, and S1
interface handover.

Explanation

Receipt of the HANDOVER PREPARATION FAILURE message by The


eNodeB or timeout etc. it indicates the handover preparation failure. If
the handover cause is coverage and the handover type is intra-freq, the
failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


fails.

9.4.1.3.3 C373485102 Number of Successful Outgoing Inter-Cell Intra-freq Handover Execution based Covering
Definition

The counter is used to count the number of successful outgoing intra-freq


handovers execution for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover completes. The sampling point changes
with the handover type. For details, refer to the descriptions of Sampling
Point of intra-eNB handover, X2 interface handover, and S1 interface
handover.

Explanation

When eNodeB receives the UE CONTEXT RELEASE message sent


from the target cell to the source cell or the UE CONTEXT RELEASE
COMMAND sent from the MME to the source eNodeB, it indicates a
successful handover.If the handover cause is coverage and the handover
type is intra-freq, the message is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


completes.
9-112

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.4.1.3.4 C373485103 Number of Outgoing Inter-Cell Intra-freq Handover Execution Failure based Covering
Definition

The counter is used to count the number of outgoing intra-freq handovers


execution failures for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover fails. The sampling point changes with the
handover type. For details, refer to the descriptions of Sampling Point of
intra-eNB handover, X2 interface handover, and S1 interface handover.

Explanation

Not receipt of the RRCConnectionReestablishmentComplete message by


The eNodeB or timeout etc. it indicates the handover execution failure. If
the handover cause is coverage and the handover type is intra-freq, the
failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


fails.

9.4.1.3.5 C373485104 Number of Successful Outgoing Inter-Cell Inter-freq Handover Preparation based Covering
Definition

The counter is used to count the number of successful outgoing inter-freq


handovers preparation for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation completes. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNB handover, X2 interface handover, and S1
interface handover.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing inter-eNB handover. If the handover cause is coverage and
the handover type is inter-freq, each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


completes.

9-113
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.4.1.3.6 C373485105 Number of Outgoing Inter-Cell Inter-freq Handover Preparation Failure based Covering
Definition

The counter is used to count the number of outgoing inter-freq handovers


preparation failures for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation fails. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNB handover, X2 interface handover, and S1
interface handover.

Explanation

Receipt of the HANDOVER PREPARATION FAILURE message by the


eNodeB or timeout etc. it indicates the handover preparation failure. If
the handover cause is coverage and the handover type is inter-freq, the
failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


fails.

9.4.1.3.7 C373485106 Number of Successful Outgoing Inter-Cell Inter-freq Handover Execution based Covering
Definition

The counter is used to count the number of successful outgoing inter-freq


handovers execution for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover completes. The sampling point changes
with the handover type. For details, refer to the descriptions of Sampling
Point of intra-eNB handover, X2 interface handover, and S1 interface
handover.

Explanation

When eNodeB receives the UE CONTEXT RELEASE message sent


from the target cell to the source cell or the UE CONTEXT RELEASE
COMMAND sent from the MME to the source eNodeB, it indicates a
successful handover based on the coverage.If the handover cause is
coverage and the handover type is inter-freq, the message is added to
the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


completes.

9-114
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.4.1.3.8 C373485107 Number of Outgoing Inter-Cell Inter-freq Handover Execution Failure based Covering
Definition

The counter is used to count the number of outgoing inter-freq handovers


execution failures for covering.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover fails. The sampling point changes with the
handover type. For details, refer to the descriptions of Sampling Point of
intra-eNB handover, X2 interface handover, and S1 interface handover.

Explanation

Not receipt of the RRCConnectionReestablishmentComplete message by


the eNodeB or timeout etc. it indicates the handover execution failure. If
the handover cause is coverage and the handover type is inter-freq, the
failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


fails.

9.4.2 Handover Based on Loadbalance


9.4.2.1 Flow Charts and Sampling Points
No chart.

9.4.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373485108

Number of Successful Outgoing Inter-Cell Inter-freq Handover Preparation


based LoadBalance

C373485109

Number of Outgoing Inter-Cell Inter-freq Handover Preparation Failure


based LoadBalance

C373485110

Number of Successful Outgoing Inter-Cell Inter-freq Handover Execution


based LoadBalance

C373485111

Number of Outgoing Inter-Cell Inter-freq Handover Execution Failure based


LoadBalance

C373485112

Number of Outgoing X2 Handover Preparation Attemps based LoadBalance

C373485113

Number of Successful Outgoing X2 Handover Preparation based


LoadBalance

9-115
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
7

C373485114

Number of Outgoing X2 Handover Preparation Failure based LoadBalance

C373485115

Number of Successful Outgoing X2 Handover based LoadBalance

C373485116

Number of Successful Outgoing X2 Handover Execution Failure based


LoadBalance

10

C373485117

Number of Outgoing X2 Handover Cancels based LoadBalance

11

C373485118

Number of Incoming X2 Handover Preparation Attemps based LoadBalance

12

C373485119

Number of Successful Incoming X2 Handover Preparation based


LoadBalance

13

C373485120

Number of Incoming X2 Handover Preparation Failure based LoadBalance

14

C373485121

Number of Successful Incoming X2 Handover based LoadBalance

15

C373485122

Number of Incoming X2 Handover Cancels based LoadBalance

16

C373733300

UL Unbalance Degree before HO between Serving Cell and Neighbor Cell

17

C373733301

DL Unbalance Degree before HO between Serving Cell and Neighbor Cell

18

C373733302

UL Unbalance Degree Estimate after HO between Serving Cell and


Neighbor Cell

19

C373733303

DL Unbalance Degree Estimate after HO between Serving Cell and


Neighbor Cell

9.4.2.3 Counter Description


9.4.2.3.1 C373485108 Number of Successful Outgoing Inter-Cell Inter-freq Handover Preparation based
LoadBalance
Definition

The counter is used to count the number of successful outgoing inter-freq


handovers preparation for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation completes. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNB handover, X2 interface handover, and S1
interface handover.

9-116
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing inter-eNB handover. If the handover cause is LoadBalance and
the handover type is inter-freq, each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


completes.

9.4.2.3.2 C373485109 Number of Outgoing Inter-Cell Inter-freq Handover Preparation Failure based LoadBalance
Definition

The counter is used to count the number of outgoing inter-freq handovers


preparation failures for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation fails. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNB handover, X2 interface handover, and S1
interface handover.

Explanation

Receipt of the HANDOVER PREPARATION FAILURE message by the


eNodeB or timeout etc. it indicates the handover preparation failure. If
the handover cause is LoadBalance and the handover type is inter-freq,
the failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


fails.

9.4.2.3.3 C373485110 Number of Successful Outgoing Inter-Cell Inter-freq Handover Execution based LoadBalance
Definition

The counter is used to count the number of successful outgoing inter-freq


handovers execution for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover completes. The sampling point changes
with the handover type. For details, refer to the descriptions of Sampling
Point of intra-eNB handover, X2 interface handover, and S1 interface
handover.

9-117
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When eNodeB receives the UE CONTEXT RELEASE message sent


from the target cell to the source cell or the UE CONTEXT RELEASE
COMMAND sent from the MME to the source eNodeB, it indicates a
successful handover.If the handover cause is LoadBalance and the
handover type is inter-freq, the message is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


completes.

9.4.2.3.4 C373485111 Number of Outgoing Inter-Cell Inter-freq Handover Execution Failure based LoadBalance
Definition

The counter is used to count the number of outgoing inter-freq handovers


execution failures for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover fails. The sampling point changes with the
handover type. For details, refer to the descriptions of Sampling Point of
intra-eNB handover, X2 interface handover, and S1 interface handover.

Explanation

Not receipt of the RRCConnectionReestablishmentComplete message by


the eNodeB or timeout etc. it indicates the handover execution failure. If
the handover cause is LoadBalance and the handover type is inter-freq,
the failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


fails.

9.4.2.3.5 C373485112 Number of Outgoing X2 Handover Preparation Attemps based LoadBalance


Definition

The counter is used to count the number of attempted outgoing handovers


preparation for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequest message to the


target eNodeB.

Explanation

The counter provides the numberof attempted outgoing handovers


preparation for loadbalance via X2 interface.

9-118
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverRequest message to the target eNodeB and the handover cause
is LoadBalance.

9.4.2.3.6 C373485113 Number of Successful Outgoing X2 Handover Preparation based LoadBalance


Definition

The counter is used to count the number of successful outgoing handovers


preparation for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the HandoverRequestAcknowledge


message from the target eNodeB.

Explanation

The counter provides the number of successful outgoing handovers


preparation for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the source eNodeB receives the


HandoverRequestAcknowledge message from the target eNodeB and the
handover cause is LoadBalance.

9.4.2.3.7 C373485114 Number of Outgoing X2 Handover Preparation Failure based LoadBalance


Definition

The counter is used to count the number of outgoing handovers preparation


failures for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the HandoverPreparationfailure


message from the target eNodeB,the timer waitting for the
HandoverPreparationfailure message expires or other reason.

Explanation

The counter provides the number of outgoing handovers preparation


failures for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the source eNodeB receives the


HandoverPreparationfailure message from the target eNodeB,the timer
waitting for the HandoverPreparationfailure message expires or other
reason and the handover cause is LoadBalance.

9-119
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.4.2.3.8 C373485115 Number of Successful Outgoing X2 Handover based LoadBalance


Definition

The counter is used to count the number of successful outgoing handovers


execution for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextRelease message from


the target eNodeB.

Explanation

The counter provides the number of successful outgoing handovers


execution for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UEContextRelease message from the target eNodeB and the handover
cause is LoadBalance.

9.4.2.3.9 C373485116 Number of Successful Outgoing X2 Handover Execution Failure based LoadBalance
Definition

The counter is used to count the number of outgoing handovers execution


failures for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB's timer waitting for the UEContextRelease message


expires or the eNodeB receives the RRCConnectionReestablishment
message after sending the RRCConnectionReconfiguration message.

Explanation

The counter provides the number of outgoing handovers execution failures


for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the eNodeB's timer waitting


for the UEContextRelease message expires or the eNodeB receives
the RRCConnectionReestablishment message after sending the
RRCConnectionReconfiguration message and the handover cause is
LoadBalance.

9.4.2.3.10 C373485117 Number of Outgoing X2 Handover Cancels based LoadBalance


Definition

The counter is used to count the number of outgoing handover cancel for
loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-120

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverCancel message to the


target eNodeB.

Explanation

The counter provides the number of outgoing handover cancel for


loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverCancel message to the target eNodeB and the handover cause
is LoadBalance.

9.4.2.3.11 C373485118 Number of Incoming X2 Handover Preparation Attemps based LoadBalance


Definition

The counter is used to count the number of attempted incoming handovers


preparation for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the HandoverRequest message from


the source eNodeB.

Explanation

The counter provides the number of attempted incoming handovers


preparation for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the target eNodeB receives the


HandoverRequest message from the source eNodeB and the handover
cause is LoadBalance.

9.4.2.3.12 C373485119 Number of Successful Incoming X2 Handover Preparation based LoadBalance


Definition

The counter is used to count the number of successful incoming handovers


preparation for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverRequestAcknowledge


message to the source eNodeB.

Explanation

The counter provides the number of successful incoming handovers


preparation for loadbalance via X2 interface.

9-121
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAcknowledge message to the source eNodeB and the
handover cause is LoadBalance.

9.4.2.3.13 C373485120 Number of Incoming X2 Handover Preparation Failure based LoadBalance


Definition

The counter is used to count the number of incoming handovers


preparation failures for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the HandoverPreprationFailure message


to the source eNodeB.

Explanation

The counter provides the number of incoming handovers preparation


failures for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverPreprationFailure message to the source eNodeB and the
handover cause is LoadBalance.

9.4.2.3.14 C373485121 Number of Successful Incoming X2 Handover based LoadBalance


Definition

The counter is used to count the number of successful incoming handovers


execution for loadbalance via X2 interface.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB sends the UEContextRelease message to the


source eNodeB.

Explanation

The counter provides the number of successful incoming handovers


execution for loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the target eNodeB sends the


UEContextRelease message to the source eNodeB and the handover
cause is LoadBalance.

9.4.2.3.15 C373485122 Number of Incoming X2 Handover Cancels based LoadBalance


Definition

The counter is used to count the number of incoming handover cancel for
loadbalance via X2 interface.

Sampling Interval

Event triggered
9-122

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the target eNodeB receives the HandoverCancel message from


the source eNodeB.

Explanation

The counter provides the number of incoming handover cancel for


loadbalance via X2 interface.

Updated

The counter is incremented by 1 when the target eNodeB receives the


HandoverCancel message from the source eNodeB and the handover
cause is LoadBalance.

9.4.2.3.16 C373733300 UL Unbalance Degree before HO between Serving Cell and Neighbor Cell
Definition

The counter is used to show the UL unbalance degree before HO between


serving cell and neighbor cell.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Percent

Measurement Object

EUtran Relation

Sampling Point

When the period for load balancing is arriving, and the serving cell need
to execute load balancing.

Explanation

unbalance_degree_UL_before_HO_i = ABSOLUTE(max(ULT_s,
ucUlPRBLBExeThrdZ) max(ULT_i, ucUlPRBLBExeThrdZ))
ULT_s indicates UL PRB usage of serving cell, ULT_i indicates UL PRB
usage of neighbor cell i, ucUlPRBLBExeThrdZ indicates UL execute
threshold of radio resource for load balancing.

Updated

The counter is updated when the period for load balancing is arriving, and
the serving cell need to execute load balancing.

9.4.2.3.17 C373733301 DL Unbalance Degree before HO between Serving Cell and Neighbor Cell
Definition

The counter is used to show the DL unbalance degree before HO between


serving cell and neighbor cell.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Percent

Measurement Object

EUtran Relation

Sampling Point

When the period for load balancing is arriving, and the serving cell need
to execute load balancing.

9-123
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

unbalance_degree_DL_before_HO_i = ABSOLUTE(max(DLT_s,
ucDlPRBLBExeThrdZ) max(DLT_i, ucDlPRBLBExeThrdZ))
DLT_s indicates DL PRB usage of serving cell, DLT_i indicates DL PRB
usage of neighbor cell i, ucDlPRBLBExeThrdZ indicates DL execute
threshold of radio resource for load balancing.

Updated

The counter is updated when the period for load balancing is arriving, and
the serving cell need to execute load balancing.

9.4.2.3.18 C373733302 UL Unbalance Degree Estimate after HO between Serving Cell and Neighbor Cell
Definition

The counter is used to show the UL unbalance degree estimate after HO


between serving cell and neighbor cell.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Percent

Measurement Object

EUtran Relation

Sampling Point

When the period for load balancing is arriving, and the serving cell need
to execute load balancing.

Explanation

unbalance_degree_UL_after_HO_i = ABSOLUTE(max(ULT_s_after,
ucUlPRBLBExeThrdZ) max(ULT_i_after, ucUlPRBLBExeThrdZ))
ULT_s_after indicates estimated UL PRB usage of serving cell after HO,
ULT_i_after indicates estimated UL PRB usage of neighbor cell i after HO,
ucUlPRBLBExeThrdZ indicates UL execute threshold of radio resource for
load balancing.

Updated

The counter is updated when the period for load balancing is arriving, and
the serving cell need to execute load balancing.

9.4.2.3.19 C373733303 DL Unbalance Degree Estimate after HO between Serving Cell and Neighbor Cell
Definition

The counter is used to show the DL unbalance degree estimate after HO


between serving cell and neighbor cell.

Sampling Interval

Event triggered

Counter Type

Modification

Unit

Percent

Measurement Object

EUtran Relation

Sampling Point

When the period for load balancing is arriving, and the serving cell need
to execute load balancing.

9-124
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

unbalance_degree_DL_after_HO_i = ABSOLUTE(max(DLT_s_after,
ucDlPRBLBExeThrdZ) max(DLT_i_after, ucDlPRBLBExeThrdZ))
DLT_s_after indicates estimated DL PRB usage of serving cell after HO,
DLT_i_after indicates estimated DL PRB usage of neighbor cell i after HO,
ucDlPRBLBExeThrdZ indicates DL execute threshold of radio resource for
load balancing.

Updated

The counter is updated when the period for load balancing is arriving, and
the serving cell need to execute load balancing.

9.4.3 Handover Based on Other Case


9.4.3.1 Flow Charts and Sampling Points
No chart.

9.4.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373485123

Number of Successful Outgoing Inter-Cell Intra-freq Handover Preparation


based LoadBalance

C373485124

Number of Outgoing Inter-Cell Intra-freq Handover Preparation Failure


based LoadBalance

C373485125

Number of Successful Outgoing Inter-Cell Intra-freq Handover Execution


based LoadBalance

C373485126

Number of Outgoing Inter-Cell Intra-freq Handover Execution Failure based


LoadBalance

C373485133

Number of Outgoing Handover Preparation Attemps(CSFB)

C373485135

Number of Outgoing Handover Preparation Attemps(Trigged by PCI Modify)

C373485136

Number of Outgoing Handover Preparation Attemps(Trigged by Service


Handovers)

C373485137

Number of Outgoing Handover Preparation Attemps(Based on Coverage


Measurement)

C373485138

Number of Outgoing Handover Preparation Attemps(Trigged by Overload


balance)

10

C373485139

Number of Outgoing Handover Preparation Attemps(Based on Mobile


Speed)

11

C373485141

Number of Outgoing HO Success(CSFB)

12

C373485143

Number of Outgoing HO Success(Trigged by PCI Modify)


9-125

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
13

C373485144

Number of Outgoing HO Success(Trigged by Service Handovers)

14

C373485145

Number of Outgoing HO Success(Based on Coverage Measurement)

15

C373485146

Number of Outgoing HO Success(Trigged by Overload Balance)

16

C373485147

Number of Outgoing HO Success(Based on Mobile Speed)

9.4.3.3 Counter Description


9.4.3.3.1 C373485123 Number of Successful Outgoing Inter-Cell Intra-freq Handover Preparation based
LoadBalance
Definition

The counter is used to count the number of successful outgoing intra-freq


handovers preparation for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover preparation completes. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNodeB handover, X2 interface handover, and S1
interface handover.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing inter-cell handover. If the handover cause is load balance and
the handover type is intra-freq, each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


completes.

9.4.3.3.2 C373485124 Number of Outgoing Inter-Cell Intra-freq Handover Preparation Failure based LoadBalance
Definition

The counter is used to count the number of outgoing intra-freq handovers


preparation failures for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-126
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the source cell handover preparation fails. The sampling point
changes with the handover type. For details, refer to the descriptions of
Sampling Point of intra-eNodeB handover, X2 interface handover, and S1
interface handover.

Explanation

Receipt of the HANDOVER PREPARATION FAILURE message by the


eNodeB or timeout etc. it indicates the handover preparation failure. If
the handover cause is LoadBalance and the handover type is intra-freq,
the failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover preparation


fails.

9.4.3.3.3 C373485125 Number of Successful Outgoing Inter-Cell Intra-freq Handover Execution based LoadBalance
Definition

The counter is used to count the number of successful outgoing intra-freq


handovers execution for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source cell handover completes. The sampling point changes
with the handover type. For details, refer to the descriptions of Sampling
Point of intra-eNodeB handover, X2 interface handover, and S1 interface
handover.

Explanation

When eNodeB receives the UE CONTEXT RELEASE message sent


from the target cell to the source cell or the UE CONTEXT RELEASE
COMMAND sent from the MME to the source eNodeB, it indicates a
successful handover.If the handover cause is LoadBalance and the
handover type is intra-freq, the message is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


completes.

9.4.3.3.4 C373485126 Number of Outgoing Inter-Cell Intra-freq Handover Execution Failure based LoadBalance
Definition

The counter is used to count the number of outgoing intra-freq handovers


execution failures for loadbalance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-127
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the source cell handover fails. The sampling point changes with the
handover type. For details, refer to the descriptions of Sampling Point of
intra-eNodeB handover, X2 interface handover, and S1 interface handover.

Explanation

Not receipt of the RRCConnectionReestablishmentComplete message by


the eNodeB or timeout etc. it indicates the handover execution failure. If
the handover cause is LoadBalance and the handover type is intra-freq,
the failure is added to the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


fails.

9.4.3.3.5 C373485133 Number of Outgoing Handover Preparation Attemps(CSFB)


Definition

The counter is used to count the number of attempted outgoing handovers


for CSFB.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is CSFB.

Explanation

Transmission of the RRCConnectionReconfiguration message to the UE


triggering the intra-eNodeB handover and the handover cause is CSFB.
Each RRCConnectionReconfiguration message transimtted is added to
the counter.
Transmission of the X2AP message HANDOVER REQUEST from the
source eNodeB to the target eNodeB , indicating the attempt of an outgoing
inter-eNodeB handover preparation or on transmission of S1AP message
HANDOVER REQUIRED to the MME.The handover cause is CSFB.
Transmission of the MobilityFromEUTRACommand message or the
HandoverFromEUTRAPreparationRequest message from the serving
eNodeB to the UE indicating the attempt of an outgoing handover from
EUTRAN to UTRAN or to GERAN or to CDMA2000 and the handover
cause is CSFB. Each MobilityFromEUTRACommand message or
HandoverFromEUTRAPreparationRequest message transmitted is added
to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverRequired message to the MME and the handover cause is CSFB.

9-128
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.4.3.3.6 C373485135 Number of Outgoing Handover Preparation Attemps(Trigged by PCI Modify)


Definition

The counter is used to count the number of attempted outgoing handovers


for PCI modification.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is PCI modification.

Explanation

Transmission of the RRCConnectionReconfiguration message to the UE


triggering the intra-eNodeB handover and the handover cause is PCI
modification. Each RRCConnectionReconfiguration message transimtted
is added to the counter.
Transmission of the X2AP message HANDOVER REQUEST from the
source eNodeB to the target eNodeB , indicating the attempt of an
outgoing inter-eNodeB handover preparation or on transmission of S1AP
message HANDOVER REQUIRED to the MME.The handover cause
is PCI modification.
Transmission of the MobilityFromEUTRACommand message or the
HandoverFromEUTRAPreparationRequest message from the serving
eNodeB to the UE indicating the attempt of an outgoing handover from
EUTRAN to UTRAN or to GERAN or to CDMA2000 and the handover
cause is PCI modification. Each MobilityFromEUTRACommand message
or HandoverFromEUTRAPreparationRequest message transmitted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverRequired message to the MME or sends the HandoverRequest
message to the target eNodeB and the handover cause is PCI modification.

9.4.3.3.7 C373485136 Number of Outgoing Handover Preparation Attemps(Trigged by Service Handovers)


Definition

The counter is used to count the number of attempted outgoing


intra-eNodeB handovers for service.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is service.
9-129

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Transmission of the RRCConnectionReconfiguration message


to the UE triggering the intra-eNodeB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.
Transmission of the X2AP message HANDOVER REQUEST from the
source eNodeB to the target eNodeB , indicating the attempt of an outgoing
inter-eNodeB handover preparation or on transmission of S1AP message
HANDOVER REQUIRED to the MME.
Transmission of the MobilityFromEUTRACommand message or
the HandoverFromEUTRAPreparationRequest message from
the serving eNodeB to the UE indicating the attempt of an
outgoing handover from EUTRAN to UTRAN or to GERAN or to
CDMA2000. Each MobilityFromEUTRACommand message or
HandoverFromEUTRAPreparationRequest message transmitted is added
to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverRequired message to the MME or sends the HandoverRequest
message to the target eNodeB and the handover cause is service.

9.4.3.3.8 C373485137 Number of Outgoing Handover Preparation Attemps(Based on Coverage Measurement)


Definition

The counter is used to count the number of attempted outgoing


intra-eNodeB handovers for coverage.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is coverage.

Explanation

Transmission of the RRCConnectionReconfiguration message to the UE


triggering the intra-eNodeB handover and the handover cause is coverage.
Each RRCConnectionReconfiguration message transimtted is added to
the counter.
Transmission of the X2AP message HANDOVER REQUEST from the
source eNodeB to the target eNodeB , indicating the attempt of an outgoing
inter-eNodeB handover preparation or on transmission of S1AP message
HANDOVER REQUIRED to the MME.The handover cause is coverage.
Transmission of the MobilityFromEUTRACommand message or the
HandoverFromEUTRAPreparationRequest message from the serving
eNodeB to the UE indicating the attempt of an outgoing handover from
EUTRAN to UTRAN or to GERAN or to CDMA2000 and the handover
cause is coverage. Each MobilityFromEUTRACommand message or
9-130

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

HandoverFromEUTRAPreparationRequest message transmitted is added


to the counter.
Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverRequired message to the MME or sends the HandoverRequest
message to the target eNodeB and the handover cause is coverage.

9.4.3.3.9 C373485138 Number of Outgoing Handover Preparation Attemps(Trigged by Overload balance)


Definition

The counter is used to count

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is LoadBalance.

Explanation

Transmission of the RRCConnectionReconfiguration message to the


UE triggering the intra-eNodeB handover and the handover cause is
LoadBalance. Each RRCConnectionReconfiguration message transimtted
is added to the counter.
Transmission of the X2AP message HANDOVER REQUEST from the
source eNodeB to the target eNodeB , indicating the attempt of an
outgoing inter-eNodeB handover preparation or on transmission of S1AP
message HANDOVER REQUIRED to the MME.The handover cause
is LoadBalance.
Transmission of the MobilityFromEUTRACommand message or the
HandoverFromEUTRAPreparationRequest message from the serving
eNodeB to the UE indicating the attempt of an outgoing handover from
EUTRAN to UTRAN or to GERAN or to CDMA2000 and the handover
cause is LoadBalance. Each MobilityFromEUTRACommand message or
HandoverFromEUTRAPreparationRequest message transmitted is added
to the counter.

Updated

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is load balance.

9.4.3.3.10 C373485139 Number of Outgoing Handover Preparation Attemps(Based on Mobile Speed)


Definition

The counter is used to count the number of attempted outgoing


intra-eNodeB handovers for mobility speed.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-131

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the HandoverRequired message to the


MME or sends the HandoverRequest message to the target eNodeB and
the handover cause is mobility speed.

Explanation

Transmission of the RRCConnectionReconfiguration message to the UE


triggering the intra-eNodeB handover and the handover cause is mobility
speed. Each RRCConnectionReconfiguration message transimtted is
added to the counter.
Transmission of the X2AP message HANDOVER REQUEST from the
source eNodeB to the target eNodeB , indicating the attempt of an outgoing
inter-eNodeB handover preparation or on transmission of S1AP message
HANDOVER REQUIRED to the MME.The handover cause is mobility
speed.
Transmission of the MobilityFromEUTRACommand message or the
HandoverFromEUTRAPreparationRequest message from the serving
eNodeB to the UE indicating the attempt of an outgoing handover from
EUTRAN to UTRAN or to GERAN or to CDMA2000 and the handover
cause is mobility speed. Each MobilityFromEUTRACommand message
or HandoverFromEUTRAPreparationRequest message transmitted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


HandoverRequired message to the MME or sends the HandoverRequest
message to the target eNodeB and the handover cause is mobility speed.

9.4.3.3.11 C373485141 Number of Outgoing HO Success(CSFB)


Definition

The counter is used to count the number of attempted outgoing


intra-eNodeB handovers for CSFB.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is CSFB.

9-132
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target (=source) eNodeB, indicating a successful
outgoing intra-eNodeB handover. The handover cause is CSFB. Each
RRCConnectionReconfigurationComplete message transimtted is added
to the counter.
Receipt at the source eNodeB of UE CONTEXT RELEASE over the X2
from the target eNodeB following a successful handover.The handover
cause is CSFB. Each UE CONTEXT RELEASE message received is
added to the counter.
Receipt of a S1AP message UE CONTEXT RELEASE COMMAND
sent from the MME to the source eNodeB, indicating a successful IRAT
handover. The handover cause is CSFB. Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is CSFB.

9.4.3.3.12 C373485143 Number of Outgoing HO Success(Trigged by PCI Modify)


Definition

The counter is used to count the number of successful outgoing


intra-eNodeB handovers for PCI modification.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is PCI modification.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target (=source) eNodeB, indicating a successful
outgoing intra-eNodeB handover. Each RRCConnectionReconfigurationComplete message transimtted is added to the counter.
Receipt at the source eNodeB of UE CONTEXT RELEASE over the
X2 from the target eNodeB following a successful handover. Each UE
CONTEXT RELEASE message received is added to the counter.
Receipt of a S1AP message UE CONTEXT RELEASE COMMAND
sent from the MME to the source eNodeB, indicating a successful IRAT
handover. Each UE CONTEXT RELEASE COMMAND message received
is added to the counter.

9-133
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB receives the


UEContextReleaseCommand message from the MME or receives the
UEContextRelease message from the target eNodeB and the handover
cause is PCI modification.

9.4.3.3.13 C373485144 Number of Outgoing HO Success(Trigged by Service Handovers)


Definition

The counter is used to count the number of successful outgoing


intra-eNodeB handovers for service.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is service.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target (=source) eNodeB, indicating a successful
outgoing intra-eNodeB handover. Each RRCConnectionReconfigurationComplete message transimtted is added to the counter.
Receipt at the source eNodeB of UE CONTEXT RELEASE over the
X2 from the target eNodeB following a successful handover. Each UE
CONTEXT RELEASE message received is added to the counter.
Receipt of a S1AP message UE CONTEXT RELEASE COMMAND
sent from the MME to the source eNodeB, indicating a successful IRAT
handover. Each UE CONTEXT RELEASE COMMAND message received
is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UEContextReleaseCommand message from the MME or receives the
UEContextRelease message from the target eNodeB and the handover
cause is service.

9.4.3.3.14 C373485145 Number of Outgoing HO Success(Based on Coverage Measurement)


Definition

The counter is used to count the number of successful outgoing


intra-eNodeB handovers for coverage.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-134
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is coverage.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target (=source) eNodeB, indicating a successful
outgoing intra-eNodeB handover. The handover cause is coverage. Each
RRCConnectionReconfigurationComplete message transimtted is added
to the counter.
Receipt at the source eNodeB of UE CONTEXT RELEASE over the X2
from the target eNodeB following a successful handover.The handover
cause is coverage. Each UE CONTEXT RELEASE message received is
added to the counter.
Receipt of a S1AP message UE CONTEXT RELEASE COMMAND
sent from the MME to the source eNodeB, indicating a successful IRAT
handover. The handover cause is coverage. Each UE CONTEXT
RELEASE COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UEContextReleaseCommand message from the MME or receives the
UEContextRelease message from the target eNodeB and the handover
cause is coverage.

9.4.3.3.15 C373485146 Number of Outgoing HO Success(Trigged by Overload Balance)


Definition

The counter is used to count the number of successful outgoing


intra-eNodeB handovers for load balance.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is LoadBalance.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target (=source) eNodeB, indicating a successful
outgoing intra-eNodeB handover. The handover cause is LoadBalance.
Each RRCConnectionReconfigurationComplete message transimtted is
added to the counter.
Receipt at the source eNodeB of UE CONTEXT RELEASE over the X2
from the target eNodeB following a successful handover.The handover
cause is LoadBalance. Each UE CONTEXT RELEASE message received
is added to the counter.

9-135
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB, indicating a successful IRAT
handover. The handover cause is LoadBalance. Each UE CONTEXT
RELEASE COMMAND message received is added to the counter.
Updated

The counter is incremented by 1 when the source eNodeB receives the


UEContextReleaseCommand message from the MME or receives the
UEContextRelease message from the target eNodeB and the handover
cause is load balance.

9.4.3.3.16 C373485147 Number of Outgoing HO Success(Based on Mobile Speed)


Definition

The counter is used to count the number of successful outgoing


intra-eNodeB handovers for mobility speed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the UEContextReleaseCommand


message from the MME or receives the UEContextRelease message from
the target eNodeB and the handover cause is mobility speed.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target (=source) eNodeB, indicating a successful
outgoing intra-eNodeB handover. The handover cause is mobility speed.
Each RRCConnectionReconfigurationComplete message transimtted is
added to the counter.
Receipt at the source eNodeB of UE CONTEXT RELEASE over the X2
from the target eNodeB following a successful handover.The handover
cause is mobility speed. Each UE CONTEXT RELEASE message
received is added to the counter.
Receipt of a S1AP message UE CONTEXT RELEASE COMMAND
sent from the MME to the source eNodeB, indicating a successful IRAT
handover. The handover cause is mobility speed. Each UE CONTEXT
RELEASE COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UEContextReleaseCommand message from the MME or receives the
UEContextRelease message from the target eNodeB and the handover
cause is mobility speed.

9-136
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5 Intra-Rat Intra-Freq Handover on EUtranRelation


9.5.1 Intra-eNB Intra-Freq Handover on EUtranRelation
9.5.1.1 Flow Charts and Sampling Points
Figure 9-17 Intra-eNB Handover

l
l
l
l

l
l

Sampling Point 1: The eNodeB receives the MeasurementReport message from UE.
Sampling Point 2: The eNodeB sends the RRCConnectionReconfiguration message
to UE.
Sampling Point 3: The handover execution process.
Sampling
Point
4:
The
eNodeB
receives
the
RRCConnectionReconfigurationComplete
message
from
UE
indicating
handover successfully.
Sampling
Point
5:
The
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling
Point
6:
The
eNodeB
receives
the
RRCConnectionReestablishmentRequest
message
from
UE
during
intra-eNB handover.

9-137
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.5.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373600000

C373600001

Number of Successful Outgoing Intra-eNB Intra-freq Handover Preparation


Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due
to Re-estabilshment to Source eNodeB

C373600002

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to Dest Preparation Failure

C373600003

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to Other Reason

C373600040

C373600041

Number of Successful Incoming Intra-eNB Intra-freq Handover Preparation


Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due
to Resource Allocation Fail

C373600042

Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due


to Dest Occur Reestblishment

C373600043

Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due


to Other Reason

C373600080

Number of Successful Outgoing Intra-eNB Intra-freq Handover Execution

10

C373600081

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to


Re-estabilshment to Source eNodeB

11

C373600082

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to


Dest Occur Reestblishment

12

C373600083

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due


to Other Cause

13

C373600084

Number of Successful Incoming Intra-eNB Intra-freq Handover Execution

14

C373600085

Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to


RRC Reconfig Complete Timeout

15

C373600086

Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to


Dest Occur Reestblishment

16

C373600087

Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due


to Other Cause

17

C373600088

Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due


to User Inactivity

18

C373600089

Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to


Waiting Reconfiguration Complete timeout

9-138
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5.1.3 Counter Description


9.5.1.3.1 C373600000 Number of Successful Outgoing Intra-eNB Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing Intra-eNB


Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


the UE.
Sampling Point 2

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing intra-eNB handover. Each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.5.1.3.2 C373600001 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover preparation failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.
Sampling Point 6

Explanation

The source cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during the preparation of resources in
target cell. The source reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9-139
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.5.1.3.3 C373600002 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to Dest
Preparation Failure
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover preparation failures due to target cell preparation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover preparation failures in target cell.

Explanation

Because the target cell in eNB has no enough resources, the source cell
reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures in target cell.

9.5.1.3.4 C373600003 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in source cell.

Explanation

Because the source cell in eNB occurs other failure during handover
preparation , it reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in source cell.

9.5.1.3.5 C373600040 Number of Successful Incoming Intra-eNB Intra-freq Handover Preparation


Definition

The counter is used to count the number of successful incoming Intra-eNB


Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-140
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from UE in target cell.
Sampling Point 2

Explanation

The targe cell in eNB has an successful preparation of resources indicating


a successful incoming intra-eNB handover.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from UE in target cell.

9.5.1.3.6 C373600041 Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due to Resource
Allocation Fail
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs the admission failures in target cell.

Explanation

The targe cell in eNB has an preparation failures of resources indicating a


incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs the admission


failures in target cell.

9.5.1.3.7 C373600042 Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due to Dest Occur
Reestblishment
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover preparation failures due to destination occuring Reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The targe cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover preparation indicating a
incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9-141
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.5.1.3.8 C373600043 Number of Incoming Intra-eNB Intra-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in target cell.

Explanation

The targe cell in eNB occurs other failures during handover preparation
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in target cell.

9.5.1.3.9 C373600080 Number of Successful Outgoing Intra-eNB Intra-freq Handover Execution


Definition

The counter is used to count the number of successful outgoing Intra-eNB


Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source cell receives the UeContexRelease message from the
target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the source cell receives the


UeContexRelease message from the target cell.

9.5.1.3.10 C373600081 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-142

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.

Explanation

The source cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution indicating a
outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9.5.1.3.11 C373600082 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to Dest Occur
Reestblishment
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to destination occuring Reestblishment

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the source
report handover failure indicating a outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.5.1.3.12 C373600083 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in source cell.

Explanation

The source cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

9-143
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in source cell.

9.5.1.3.13 C373600084 Number of Successful Incoming Intra-eNB Intra-freq Handover Execution


Definition

The counter is used to count the number of successful Incoming Intra-eNB


Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE in target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter in target cell.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from the UE in target
cell.

9.5.1.3.14 C373600085 Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to RRC Reconfig
Complete Timeout
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

Explanation

After successful the preparation of resources in target cell,the timer of


monitoring RRCConnectionReconfigurationComplete message expires
during handover execution.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9-144
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5.1.3.15 C373600086 Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to Dest Occur
Reestblishment
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to destination occuring Reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the target
report handover failure indicating a incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.5.1.3.16 C373600087 Number of Incoming Intra-eNB Intra-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in target cell.

Explanation

The targe cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in target cell.

9.5.1.3.17 C373600088 Number of Outgoing Intra-eNB Intra-freq Handover Preparation Failure due to User Inactivity
Definition

The counter is used to count the number of incoming Intra-eNB Intra-freq


handover execution failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-145
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover, the source cell detects the user inactive then
trigger UE release.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.5.1.3.18 C373600089 Number of Outgoing Intra-eNB Intra-freq Handover Execution Failure due to Waiting
Reconfiguration Complete timeout
Definition

The counter is used to count the number of outgoing Intra-eNB Intra-freq


handover execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

Explanation

After successful the preparation of resources in target cell during handover


execution,the timer of monitoring RRCConnectionReconfigurationComplete
message expires.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9.5.2 Inter-eNB X2 Intra-Freq Handover on EUtranRelation


9.5.2.1 Flow Charts and Sampling Points

9-146
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Figure 9-18 X2 Handover(1)

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequest message to the
target eNodeB.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the source eNodeB.
Sampling Point 3: The source eNodeB receives the HandoverRequestAcknowledge
message from the target eNodeB.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to the source eNodeB.
Sampling
Point
5:
The
source
eNodeB
occurs
timeout
for
HandoverRequestAcknowledge message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the target eNodeB.
Sampling Point 7: The target eNodeB sends the HandoverPreprationFailure message
to the source eNodeB.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
9-147

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l
l
l
l
l

Sampling
Point
9:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
10:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 11: The target eNodeB sends the PathSwitchRequest message to
MME.
Sampling Point 12: The target eNodeB receives the PathSwitchAck message from
MME.
Sampling Point 13: The target eNodeB receives the PathSwitchFailure message from
MME.
Sampling Point 14: The target eNodeB occurs timeout for PathSwitchAck message.
Sampling Point 15: The target eNodeB sends the UEContextRelease message to the
source eNodeB.
Sampling Point 16: The source eNodeB receives the UEContextRelease message
from the target the eNodeB.
Sampling Point 17: The source eNodeB occurs timeout for UEContextRelease
message.

Figure 9-19 X2 Handover(2)

Sampling
Point
20:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB X2 handover.

the
during

9-148
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373610300

Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover


Preparation

C373610301

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to HO Request ACK Timeout

C373610302

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Dest Preparation Failure

C373610303

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Other Reason

C373610304

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373610340

Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover


Preparation

C373610341

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Resource Allocation Fail

C373610342

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Source Cancle HO

C373610343

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Other Reason

10

C373610380

Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover


Execution

11

C373610381

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373610382

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373610383

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Other Cause

14

C373610384

Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover


Execution

15

C373610385

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

16

C373610386

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Path Switch Failure

17

C373610387

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Other Cause

9-149
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
18

C373610388

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Source Cancel HO

19

C373610389

Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to User Inactivity

20

C373610390

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

21

C373610391

Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9.5.2.3 Counter Description


9.5.2.3.1 C373610300 Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 3

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the X2 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.5.2.3.2 C373610301 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
HO Request ACK Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to handover request ack
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-150

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverRequestAck


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequst message from the source


eNodeB to the MME, the timer of monitoring the HandoverRequestAck
message expires. Then the source sends the HandoverCancel message
to the target eNodeB. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverRequestAck message expires.

9.5.2.3.3 C373610302 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the target eNodeB.
Sampling Point 6

Explanation

After transmission of the HandoverRequest message from the


source eNodeB to the target eNodeB, the source receives the
HandoverPreparationFailure message from the target eNodeB. It indicates
the handover has failed.Each HandoverPreparationFailure message
received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the target eNodeB.

9.5.2.3.4 C373610303 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-151

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source occurs other failures. Then the
source send HandoverCancel message to the target eNodeB. It indicates
the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.5.2.3.5 C373610304 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source eNodeB receives the RRC
CONNECTION REESTABLISHMENT REQUEST message from the UE. It
indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.5.2.3.6 C373610340 Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via X2) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the source eNodeB.
Sampling Point 4
9-152

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the source eNodeB indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


Request Ack message to the source eNodeB.

9.5.2.3.7 C373610341 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover Preparation failure message to


the source eNodeB due to admission failures.
Sampling Point 7

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
has no enough resource then sends the HANDOVER PREPARATION
FAILURE message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


Preparation failure message to the source eNodeB due to admission
failures.

9.5.2.3.8 C373610342 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Source Cancle HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Intra-freq handover preparation failures due to source
cancle handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

9-153
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the HANDOVER CANCEL message from the source eNodeB
indicating handover failure.Each the HANDOVER CANCEL message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9.5.2.3.9 C373610343 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
occur other failures then sends the HANDOVER PREPARATION FAILURE
message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.5.2.3.10 C373610380 Number of Successful Outgoing Inter-eNB(via X2) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release message


from the detination eNodeB.
Sampling Point 16

Explanation

When eNodeB receives a X2AP message UE CONTEXT RELEASE sent


from the target eNodeB to the source eNodeB, it indicates a successful
handover over the X2. Each UE CONTEXT RELEASE message received
is added to the counter.
9-154

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the source eNodeB receives the UE


Context Release message from the detination eNodeB.

9.5.2.3.11 C373610381 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover execution failures due to source eNB receives the
RRC Connection reestablishment Request message from the UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 20

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by the


source eNodeB from the UE during handover, the HANDOVER CANCEL
message is sent to by the source eNodeB to the target eNodeB. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.5.2.3.12 C373610382 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 17

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the timer of monitoring the message
expires.Then the source trigger UE release.

9-155
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.5.2.3.13 C373610383 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the other reason occurs.Then the
source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.5.2.3.14 C373610384 Number of Successful Incoming Inter-eNB(via X2) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via X2) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE message to


the source eNodeB.
Sampling Point 15

Explanation

Transmission of a X2AP message UE CONTEXT RELEASE sent from


source eNB to the target eNodeB, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE message received is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE message to the source eNodeB.

9-156
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5.2.3.15 C373610385 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover execution failures due to RRC Reconfig Complete
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfiguration Complete message expires.
Sampling Point 10

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the timer
of monitoring the RRCConnectionReconfigurationComplete message
expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfiguration Complete message expires.

9.5.2.3.16 C373610386 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Path Switch Failure
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the PathSwitchRequestFailure message


or the timer of waiting for the PathSwitchACK message expires.
Sampling Point 13, Sampling Point 14

Explanation

After transmission of PATH SWITCH REQUEST message from target eNB


to the MME,the target receives the PATH SWITCH REQUEST FAILURE
message from the MME indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE message is added to the
counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


the PathSwitchRequestFailure message or the timer of waiting for the
PathSwitchACK message expires.

9-157
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.5.2.3.17 C373610387 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target occur
other failures then trigger UE release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.5.2.3.18 C373610388 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter counts the number of failed intra-frequency outgoing


handovers on the X2 interfaces between ENBs because the handover is
canceled by the source side.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

Explanation

After transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the source eNodeB to the target eNodeB, the
source eNodeB receives the RRCConnectionReestablishmentRequest
message from the UE. The HANDOVER CANCEL message is sent to by
the source eNodeB to the target eNodeB.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9.5.2.3.19 C373610389 Number of Outgoing Inter-eNB(via X2) Intra-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Intra-freq handover preparation failures due to user inactive.
9-158

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

The eNodeB detects that the UE's state is "inactive" during handover
preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.5.2.3.20 C373610390 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Intra-freq handover preparation failures due to RRC
connection reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the RRCConnectionReestablishmentRequest message from the
UE then sends the HANDOVER FAILURE message to the source eNodeB
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.5.2.3.21 C373610391 Number of Incoming Inter-eNB(via X2) Intra-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


X2) Intra-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered
9-159

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target
receives the RRCConnectionReestablishmentRequest message from the
UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.5.3 Inter-eNB S1 Intra-Freq Handover on EUtranRelation


9.5.3.1 Flow Charts and Sampling Points

9-160
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Figure 9-20 S1 Handover(1)

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
9-161

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-21 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.5.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373620600

Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover


Preparation

C373620601

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to HO Command Timeout

9-162
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
3

C373620602

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Dest Preparation Failure

C373620603

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Other Reason

C373620604

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373620640

Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover


Preparation

C373620641

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Resource Allocation Fail

C373620642

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Source Cancel HO

C373620643

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Other Reason

10

C373620680

Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover


Execution

11

C373620681

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373620682

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373620683

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Other Cause

14

C373620684

Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover


Execution

15

C373620685

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

16

C373620686

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Source Cancel HO

17

C373620687

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Other Cause

18

C373620688

Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to User Inactivity

19

C373620689

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

20

C373620690

Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9-163
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.5.3.3 Counter Description


9.5.3.3.1 C373620600 Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 8

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the S1 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.5.3.3.2 C373620601 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to handover command timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source sends the HandoverCancel message
to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9-164
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5.3.3.3 C373620602 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationFailures
message from the MME. It indicates the handover has failed.Each
HandoverPreparationFailures message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9.5.3.3.4 C373620603 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.5.3.3.5 C373620604 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to re-establishment.
9-165

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source eNodeB receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE. It indicates the
handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.5.3.3.6 C373620640 Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via S1) Intra-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.5.3.3.7 C373620641 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-166

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.5.3.3.8 C373620642 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Source Cancel HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Intra-freq handover preparation failures due to source
cancle handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.5.3.3.9 C373620643 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation
9-167

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.5.3.3.10 C373620680 Number of Successful Outgoing Inter-eNB(via S1) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates
a successful handover over the S1. Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.5.3.3.11 C373620681 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover execution failures due to source eNB receives the
RRC Connection Reestablishment Request message from the UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 15

9-168
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.5.3.3.12 C373620682 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the UEContextReleaseCommand message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextReleaseCommand message expires.

9.5.3.3.13 C373620683 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.
9-169

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.5.3.3.14 C373620684 Number of Successful Incoming Inter-eNB(via S1) Intra-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via S1) Intra-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReconfigurationComplete message from UE.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReconfigurationComplete message from UE.

9.5.3.3.15 C373620685 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover execution failures due to RRC Reconfig Complete
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9-170
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.5.3.3.16 C373620686 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.5.3.3.17 C373620687 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Intra-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.5.3.3.18 C373620688 Number of Outgoing Inter-eNB(via S1) Intra-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Intra-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered
9-171

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.5.3.3.19 C373620689 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Intra-freq handover preparation failures due to RRC
connection reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the RRCConnectionReestablishmentRequest message from the UE then
sends the HANDOVER FAILURE message to the MME indicating the
handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.5.3.3.20 C373620690 Number of Incoming Inter-eNB(via S1) Intra-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


S1) Intra-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-172

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the RRCConnectionReestablishmentRequest message from the UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.6 Intra-Rat Inter-Freq Handover on EUtranRelation


9.6.1 Intra-eNB Inter-Freq Handover on EUtranRelation
9.6.1.1 Flow Charts and Sampling Points
Figure 9-22 Intra-eNB Handover

Sampling Point 1: The eNodeB receives the MeasurementReport message from UE.

9-173
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l

Sampling Point 2: The eNodeB sends the RRCConnectionReconfiguration message


to UE.
Sampling Point 3: The handover execution process.
Sampling Point 4: The eNodeB receives the RRCConnectionReconfigurationComplete message from UE indicating handover successfully.
Sampling
Point
5:
The
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling
Point
6:
The
eNodeB
receives
the
RRCConnectionReestablishmentRequest
message
from
UE
during
intra-eNB handover.

9.6.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373630900

C373630901

Number of Successful Outgoing Intra-eNB Inter-freq Handover Preparation


Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due
to Re-estabilshment to Source eNodeB

C373630902

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to Dest Preparation Failure

C373630903

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to Other Reason

C373630940

Number of Successful Incoming Intra-eNB Inter-freq Handover Preparation

C373630941

Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due


to Resource Allocation Fail

C373630942

Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due


to Dst occur Re-establishment

C373630943

Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due


to Other Reason

C373630980

Number of Successful Outgoing Intra-eNB Inter-freq Handover Execution

10

C373630981

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to


Re-estabilshment to Source eNodeB

11

C373630982

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to


Dst occur Re-establishment

12

C373630983

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due


to Other Cause

13

C373630984

Number of Successful Incoming Intra-eNB Inter-freq Handover Execution

14

C373630985

Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to


RRC Reconfig Complete Timeout

9-174
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
15

C373630986

Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to


Dst occur Re-establishment

16

C373630987

Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due


to Other Cause

17

C373630988

Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due


to User Inactivity

18

C373630989

Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to


Waiting Reconfiguration Complete Timeout

9.6.1.3 Counter Description


9.6.1.3.1 C373630900 Number of Successful Outgoing Intra-eNB Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing Intra-eNB


Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message to


the UE.
Sampling Point 2

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover,it indicates the successful preparation of an
outgoing intra-eNB handover. Each RRCConnectionReconfiguration
message transimtted is added to the counter.

Updated

The counter is incremented by 1 when the eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.6.1.3.2 C373630901 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover preparation failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation
9-175

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.
Sampling Point 6

Explanation

The source cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during the preparation of resources in
target cell. The source reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9.6.1.3.3 C373630902 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to Dest
Preparation Failure
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover preparation failures due to target cell preparation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover preparation failures in target cell.

Explanation

Because the target cell in eNB has no enough resources, the source cell
reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures in target cell.

9.6.1.3.4 C373630903 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in source cell.

Explanation

Because the source cell in eNB occurs other failure during handover
preparation , it reports handover preparation failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in source cell.

9-176
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.6.1.3.5 C373630940 Number of Successful Incoming Intra-eNB Inter-freq Handover Preparation


Definition

The counter is used to count the number of successful incoming Intra-eNB


Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from UE in target cell.
Sampling Point 2

Explanation

The targe cell in eNB has an successful preparation of resources indicating


a successful incoming intra-eNB handover.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from UE in target cell.

9.6.1.3.6 C373630941 Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due to Resource
Allocation Fail
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs the admission failures in target cell.

Explanation

The targe cell in eNB has an preparation failures of resources indicating a


incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs the admission


failures in target cell.

9.6.1.3.7 C373630942 Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due to Dst occur
Re-establishment
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover preparation failures due to destination occuring Reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-177
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover preparation indicating a
incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.6.1.3.8 C373630943 Number of Incoming Intra-eNB Inter-freq Handover Preparation Failure due to Other Reason
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover preparation failures due to other


reason in target cell.

Explanation

The targe cell in eNB occurs other failures during handover preparation
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


preparation failures due to other reason in target cell.

9.6.1.3.9 C373630980 Number of Successful Outgoing Intra-eNB Inter-freq Handover Execution


Definition

The counter is used to count the number of successful outgoing Intra-eNB


Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source cell receives the UeContexRelease message from the
target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter.

9-178
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the source cell receives the


UeContexRelease message from the target cell.

9.6.1.3.10 C373630981 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to reestablishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in source cell.

Explanation

The source cell in eNB has received the a RRCConnectionReestablishmentRequest message from the UE during handover execution indicating
a outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in source cell.

9.6.1.3.11 C373630982 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to Dst occur
Re-establishment
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to destination occuring Reestblishment

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the source
report handover failure indicating a outgoing intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.6.1.3.12 C373630983 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to other reason.
9-179

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in source cell.

Explanation

The source cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in source cell.

9.6.1.3.13 C373630984 Number of Successful Incoming Intra-eNB Inter-freq Handover Execution


Definition

The counter is used to count the number of successful Incoming Intra-eNB


Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message from the UE in target cell.
Sampling Point 4

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target cell in eNB, indicating a successful outgoing
intra-eNB handover. Each RRCConnectionReconfigurationComplete
message transimtted is added to the counter in target cell.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message from the UE in target
cell.

9.6.1.3.14 C373630985 Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to RRC Reconfig
Complete Timeout
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-180
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

Explanation

After successful the preparation of resources in target cell,the timer of


monitoring RRCConnectionReconfigurationComplete message expires
during handover execution.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9.6.1.3.15 C373630986 Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to Dst occur
Re-establishment
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to destination occuring Reestblishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB receives the RRCConnectionReestablishmentRequest


message from UE in target cell.
Sampling Point 6

Explanation

The target cell in eNB has received the RRCConnectionReestablishmentRequest message from the UE during handover execution, the target
report handover failure indicating a incoming intra-eNB handover failure.

Updated

The counter is incremented by 1 when the eNodeB receives the


RRCConnectionReestablishmentRequest message from UE in target cell.

9.6.1.3.16 C373630987 Number of Incoming Intra-eNB Inter-freq Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB occurs handover execution failures due to other reason
in target cell.

Explanation

The targe cell in eNB occurs other failures during handover execution
indicating an incoming intra-eNB handover failure.

9-181
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB occurs handover


execution failures due to other reason in target cell.

9.6.1.3.17 C373630988 Number of Outgoing Intra-eNB Inter-freq Handover Preparation Failure due to User Inactivity
Definition

The counter is used to count the number of incoming Intra-eNB Inter-freq


handover execution failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover, the source cell detects the user inactive then
trigger UE release.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.6.1.3.18 C373630989 Number of Outgoing Intra-eNB Inter-freq Handover Execution Failure due to Waiting
Reconfiguration Complete Timeout
Definition

The counter is used to count the number of outgoing Intra-eNB Inter-freq


handover execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires in target cell.
Sampling Point 5

Explanation

After successful the preparation of resources in target cell during handover


execution,the timer of monitoring RRCConnectionReconfigurationComplete
message expires.The target trigger UE release.

Updated

The counter is incremented by 1 when the eNodeB's timer of waiting for the
RRCConnectionReconfigurationComplete message expires in target cell.

9-182
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.6.2 Inter-eNB X2 Inter-Freq Handover on EUtranRelation


9.6.2.1 Flow Charts and Sampling Points
Figure 9-23 X2 Handover(1)

l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequest message to the
target eNodeB.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the source eNodeB.
Sampling Point 3: The source eNodeB receives the HandoverRequestAcknowledge
message from the target eNodeB.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to the source eNodeB.
Sampling
Point
5:
The
source
eNodeB
occurs
timeout
for
HandoverRequestAcknowledge message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the target eNodeB.
9-183

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l
l
l
l
l
l
l

Sampling Point 7: The target eNodeB sends the HandoverPreprationFailure message


to the source eNodeB.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
Sampling
Point
9:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling Point 10: The target eNodeB occurs timeout for RRCConnectionReconfigurationComplete.
Sampling Point 11: The target eNodeB sends the PathSwitchRequest message to
MME.
Sampling Point 12: The target eNodeB receives the PathSwitchAck message from
MME.
Sampling Point 13: The target eNodeB receives the PathSwitchFailure message from
MME.
Sampling Point 14: The target eNodeB occurs timeout for PathSwitchAck message.
Sampling Point 15: The target eNodeB sends the UEContextRelease message to the
source eNodeB.
Sampling Point 16: The source eNodeB receives the UEContextRelease message
from the target the eNodeB.
Sampling Point 17: The source eNodeB occurs timeout for UEContextRelease
message.

Figure 9-24 X2 Handover(2)

9-184
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling
Point
20:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB X2 handover.

the
during

9.6.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373641200

Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover


Preparation

C373641201

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to HO Request ACK Timeout

C373641202

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Dest Preparation Failure

C373641203

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Other Reason

C373641204

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373641240

Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover


Preparation

C373641241

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Resource Allocation Fail

C373641242

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Source Cancel HO

C373641243

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Other Reason

10

C373641280

Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover


Execution

11

C373641281

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373641282

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373641283

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Other Cause

14

C373641284

Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover


Execution

15

C373641285

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

9-185
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
16

C373641286

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Path Switch Failure

17

C373641287

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Other Cause

18

C373641288

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Source Cancel HO

19

C373641289

Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to User Inactivity

20

C373641290

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

21

C373641291

Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9.6.2.3 Counter Description


9.6.2.3.1 C373641200 Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 3

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the X2 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9-186
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.6.2.3.2 C373641201 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
HO Request ACK Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to handover request ack
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverRequestAck


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequst message from the source


eNodeB to the MME, the timer of monitoring the HandoverRequestAck
message expires. Then the source sends the HandoverCancel message
to the target eNodeB. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverRequestAck message expires.

9.6.2.3.3 C373641202 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Dest Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the target eNodeB.
Sampling Point 6

Explanation

After transmission of the HandoverRequest message from the


source eNodeB to the target eNodeB, the source receives the
HandoverPreparationFailure message from the target eNodeB. It indicates
the handover has failed.Each HandoverPreparationFailure message
received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the target eNodeB.

9-187
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.6.2.3.4 C373641203 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source occurs other failures. Then the
source send HandoverCancel message to the target eNodeB. It indicates
the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.6.2.3.5 C373641204 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequest message from the source


eNodeB to the target eNodeB, the source eNodeB receives the RRC
CONNECTION REESTABLISHMENT REQUEST message from the UE. It
indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.6.2.3.6 C373641240 Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via X2) Inter-freq handover preparation.
9-188

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover Request Ack message to the
source eNodeB.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the source eNodeB indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


Request Ack message to the source eNodeB.

9.6.2.3.7 C373641241 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover Preparation failure message to


the source eNodeB due to admission failures.
Sampling Point 7

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
has no enough resource then sends the HANDOVER PREPARATION
FAILURE message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


Preparation failure message to the source eNodeB due to admission
failures.

9.6.2.3.8 C373641242 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Source Cancel HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Inter-freq handover preparation failures due to source
cancle handover.

9-189
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the HANDOVER CANCEL message from the source eNodeB
indicating handover failure.Each the HANDOVER CANCEL message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9.6.2.3.9 C373641243 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
occur other failures then sends the HANDOVER PREPARATION FAILURE
message to the source eNodeB indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.6.2.3.10 C373641280 Number of Successful Outgoing Inter-eNB(via X2) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via X2) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation
9-190

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the source eNodeB receives the UE Context Release message


from the detination eNodeB.
Sampling Point 16

Explanation

When eNodeB receives a X2AP message UE CONTEXT RELEASE sent


from the target eNodeB to the source eNodeB, it indicates a successful
handover over the X2. Each UE CONTEXT RELEASE message received
is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the UE


Context Release message from the detination eNodeB.

9.6.2.3.11 C373641281 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover execution failures due to source eNB receives the
RRC Connection reestablishment Request message from the UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 20

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by the


source eNodeB from the UE during handover, the HANDOVER CANCEL
message is sent to by the source eNodeB to the target eNodeB. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.6.2.3.12 C373641282 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-191
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 17

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the timer of monitoring the message
expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.6.2.3.13 C373641283 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover execution failures due to other reason, e.g. The
eNodeB failed to send the RRC Connection Reconfiguration message to
the UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a X2AP message UE CONTEXT RELEASE sent from the


target eNodeB to the source eNodeB,the other reason occurs.Then the
source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.6.2.3.14 C373641284 Number of Successful Incoming Inter-eNB(via X2) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via X2) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE message to


the source eNodeB.
Sampling Point 15

9-192
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Transmission of a X2AP message UE CONTEXT RELEASE sent from


source eNB to the target eNodeB, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE message received is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE message to the source eNodeB.

9.6.2.3.15 C373641285 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover execution failures due to RRC Reconfig Complete
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 10

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the timer
of monitoring RRCConnectionReconfigurationComplete message
expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfiguration Complete message expires.

9.6.2.3.16 C373641286 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Path Switch Failure
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the PathSwitchRequestFailure message


or the timer of waiting for the PathSwitchACK message expires.
Sampling Point 13, Sampling Point 14

9-193
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After transmission of PATH SWITCH REQUEST message from target eNB


to the MME,the target receives the PATH SWITCH REQUEST FAILURE
message from the MME indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE message is added to the
counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


the PathSwitchRequestFailure message or the timer of waiting for the
PathSwitchACK message expires.

9.6.2.3.17 C373641287 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via X2)


Inter-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target occur
other failures then trigger UE release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.6.2.3.18 C373641288 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter counts the number of failed Inter-frequency outgoing


handovers on the X2 interfaces between ENBs because the handover is
canceled by the source side.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives Handover Cancel message from the
source eNodeB.

9-194
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

After transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the source eNodeB to the target eNodeB, the
source eNodeB receives the RRCConnectionReestablishmentRequest
message from the UE. The HANDOVER CANCEL message is sent to by
the source eNodeB to the target eNodeB.

Updated

The counter is incremented by 1 when the target eNodeB receives


Handover Cancel message from the source eNodeB.

9.6.2.3.19 C373641289 Number of Outgoing Inter-eNB(via X2) Inter-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via X2)


Inter-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.6.2.3.20 C373641290 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via X2) Inter-freq handover preparation failures due to RRC
connection reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

9-195
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After receipt of the HandoverRequest message sent by the source eNodeB


to the target eNodeB to request the preparation of resources,the target
receives the RRCConnectionReestablishmentRequest message from the
UE then sends the HANDOVER FAILURE message to the source eNodeB
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.6.2.3.21 C373641291 Number of Incoming Inter-eNB(via X2) Inter-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


X2) Inter-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After transmission of a X2AP message HANDOVER REQUEST


ACKNOWLEDGE from target eNB to the source eNodeB,the target
receives the RRCConnectionReestablishmentRequest message from the
UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.6.3 Inter-eNB S1 Inter-Freq Handover on EUtranRelation


9.6.3.1 Flow Charts and Sampling Points

9-196
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Figure 9-25 S1 Handover(1)

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.
9-197

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-26 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.6.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373651500

Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover


Preparation

C373651501

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to HO Command Timeout

9-198
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
3

C373651502

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Dst Preparation Failure

C373651503

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Other Reason

C373651504

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Source eNodeB

C373651540

Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover


Preparation

C373651541

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Resource Allocation Fail

C373651542

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Source Cancel HO

C373651543

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Other Reason

10

C373651580

Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover


Execution

11

C373651581

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Re-estabilshment to Source eNodeB

12

C373651582

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to UE Context Release Timeout

13

C373651583

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Other Cause

14

C373651584

Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover


Execution

15

C373651585

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to RRC Reconfig Complete Timeout

16

C373651586

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Source Cancel HO

17

C373651587

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Other Cause

18

C373651588

Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to User Inactivity

19

C373651589

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation


Failure due to Re-estabilshment to Target Cell

20

C373651590

Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure


due to Re-estabilshment to Target Cell

9-199
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.6.3.3 Counter Description


9.6.3.3.1 C373651500 Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 8

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover over the S1 from the source eNodeB to the target
eNodeB,it indicates the successful preparation of an outgoing inter-eNB
handover. Each RRCConnectionReconfiguration message transimtted is
added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.6.3.3.2 C373651501 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to handover command timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source sends the HandoverCancel message
to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9-200
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.6.3.3.3 C373651502 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Dst Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to target cell preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9.6.3.3.4 C373651503 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.6.3.3.5 C373651504 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to re-establishment.

Sampling Interval

Event triggered
9-201

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRC CONNECTION


REESTABLISHMENT REQUEST message from the UE during handover
preparation.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source eNodeB receives the RRC CONNECTION
REESTABLISHMENT REQUEST message from the UE. It indicates the
handover fails.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRC CONNECTION REESTABLISHMENT REQUEST message from the
UE during handover preparation.

9.6.3.3.6 C373651540 Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-eNB(via S1) Inter-freq handover preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.6.3.3.7 C373651541 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover preparation failures due to resource allocation failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-202

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.6.3.3.8 C373651542 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Source Cancel HO
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Inter-freq handover preparation failures due to source
cancle handover.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.6.3.3.9 C373651543 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover preparation failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-203
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.6.3.3.10 C373651580 Number of Successful Outgoing Inter-eNB(via S1) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful outgoing


Inter-eNB(via S1) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates
a successful handover over the S1. Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.6.3.3.11 C373651581 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover execution failures due to source eNB receives the
RRC Connection reestablishment Request message from the UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 15

9-204
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.6.3.3.12 C373651582 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.6.3.3.13 C373651583 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover execution failures due to other reason, e.g. The
eNodeB failed to send the RRC Connection Reconfiguration message to
the UE.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

9-205
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.6.3.3.14 C373651584 Number of Successful Incoming Inter-eNB(via S1) Inter-freq Handover Execution
Definition

The counter is used to count the number of successful Incoming


Inter-eNB(via S1) Inter-freq handover execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReconfigurationComplete message from UE.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReconfigurationComplete message from UE.

9.6.3.3.15 C373651585 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
RRC Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover execution failures due to RRC Reconfig Complete
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

9-206
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.6.3.3.16 C373651586 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Source Cancel HO
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover execution failures due to path switch failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.6.3.3.17 C373651587 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Other Cause
Definition

The counter is used to count the number of incoming Inter-eNB(via S1)


Inter-freq handover execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9-207
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.6.3.3.18 C373651588 Number of Outgoing Inter-eNB(via S1) Inter-freq Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-eNB(via S1)


Inter-freq handover preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.6.3.3.19 C373651589 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Preparation Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of times that the incoming
Inter-eNB(via S1) Inter-freq handover preparation failures due to RRC
connection reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the RRCConnectionReestablishmentRequest message from the UE then
sends the HANDOVER FAILURE message to the MME indicating the
handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9-208
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.6.3.3.20 C373651590 Number of Incoming Inter-eNB(via S1) Inter-freq Handover Execution Failure due to
Re-estabilshment to Target Cell
Definition

The counter is used to count the number of incoming Inter-eNB(via


S1) Inter-freq handover execution failures due to RRC connection
reestablishment in destination.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the RRCConnectionReestablishmentRequest message from the UE indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9-209
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.7 Inter-Rat Handover on EUtranRelation


9.7.1 LTE-UMTS Handover on EUtranRelation
9.7.1.1 Flow Charts and Sampling Points
Figure 9-27 Inter-RAT Handover

9-210
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.

9-211
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-28 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.7.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373661800

Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover


Preparation

C373661801

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation


Failure due to Resource Allocation Fail

9-212
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
3

C373661802

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation


Failure due to Source Cancel HO

C373661803

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation


Failure due to Other Reason

C373661804

Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover


Execution

C373661805

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure


due to RRC Reconfig Complete Timeout

C373661806

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure


due to Source Cancel HO

C373661807

Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure


due to Other Cause

C373661808

Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover


Preparation

10

C373661809

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to HO Command Timeout

11

C373661810

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to Dst Preparation Failure

12

C373661811

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to Other Reason

13

C373661812

Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover


Execution

14

C373661813

Number of Outgoing Inter-RAT(LTE->UTRAN)Handover Execution Failure


due to Re-estabilshment to Source eNodeB

15

C373661814

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure


due to UE Context Release Timeout

16

C373661815

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure


due to Other Cause

17

C373661816

Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Failure due to User Inactivity

9.7.1.3 Counter Description


9.7.1.3.1 C373661800 Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-RAT(UTRAN to LTE) Handover Preparation.
9-213

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 4

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.7.1.3.2 C373661801 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Preparation failures due to resource allocation fail.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 6

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.7.1.3.3 C373661802 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Preparation failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-214

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.7.1.3.4 C373661803 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.7.1.3.5 C373661804 Number of Successful Incoming Inter-RAT(UTRAN to LTE) Handover Execution


Definition

The counter is used to count the number of successful Incoming


Inter-RAT(UTRAN to LTE) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-215
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the target eNodeB sends the UE CONTEXT RELEASE COMMAND


message to MME.
Sampling Point 12

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the UE


CONTEXT RELEASE COMMAND message to MME.

9.7.1.3.6 C373661805 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure due to RRC
Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 11

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


MME to source eNodeB,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.7.1.3.7 C373661806 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Execution failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

9-216
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


MME to source eNodeB,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives


UEContextReleaseCommand message from MME.

9.7.1.3.8 C373661807 Number of Incoming Inter-RAT(UTRAN to LTE) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of incoming Inter-RAT(UTRAN to


LTE) Handover Execution failures due to Other Cause.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


MME to source eNodeB,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.7.1.3.9 C373661808 Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to UTRAN) Handover Preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 3

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the eNodeB to the UTRAN,it indicates
the successful preparation of an outgoing inter-eNB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.
9-217

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.7.1.3.10 C373661809 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due to
HO Command Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to HO Command Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 5

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source send HandoverCancel message to the
MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.7.1.3.11 C373661810 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due to
Dst Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to destination Preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.
Sampling Point 7

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationfailure
message from the MME. It indicates the handover has failed.Each
HandoverPreparationfailure message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.
9-218

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.7.1.3.12 C373661811 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due to
Other Reason
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.7.1.3.13 C373661812 Number of Successful Outgoing Inter-RAT(LTE to UTRAN) Handover Execution


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to UTRAN) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 13

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to UTRAN). Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.7.1.3.14 C373661813 Number of Outgoing Inter-RAT(LTE->UTRAN)Handover Execution Failure due to


Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN)Handover Execution failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

9-219
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.7.1.3.15 C373661814 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 14

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.7.1.3.16 C373661815 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-220
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.7.1.3.17 C373661816 Number of Outgoing Inter-RAT(LTE to UTRAN) Handover Preparation Failure due
to User Inactivity
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


UTRAN) Handover Preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.7.2 LTE-CDMA Handover on EUtranRelation


9.7.2.1 Flow Charts and Sampling Points

9-221
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 9-29 Inter-RAT Handover

9-222
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.

9-223
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-30 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.7.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373672100

Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover


Preparation

C373672101

Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure


due to Resource Allocation Fail

9-224
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
3

C373672102

Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure


due to Source Cancel HO

C373672103

Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure


due to Other Reason

C373672104

Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover


Execution

C373672105

Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure


due to RRC Reconfig Complete Timeout

C373672106

Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure


due to Source Cancel HO

C373672107

Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure


due to Other Cause

C373672108

Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover


Preparation

10

C373672109

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to HO Command Timeout

11

C373672110

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to Dst Preparation Failure

12

C373672111

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to Other Reason

13

C373672112

Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover


Execution

14

C373672113

Number of Outgoing Inter-RAT(LTE->CDMA)Handover Execution Failure


due to Re-estabilshment to Source eNodeB

15

C373672114

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure


due to UE Context Release Timeout

16

C373672115

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure


due to Other Cause

17

C373672116

Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure


due to User Inactivity

9.7.2.3 Counter Description


9.7.2.3.1 C373672100 Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-RAT(GSM to LTE) Handover Preparation.
9-225

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.
Sampling Point 1

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.7.2.3.2 C373672101 Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure due to
Resource Allocation Fail
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to resource allocation fail.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.7.2.3.3 C373672102 Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

9-226
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.7.2.3.4 C373672103 Number of Incoming Inter-RAT(CDMA to LTE) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.7.2.3.5 C373672104 Number of Successful Incoming Inter-RAT(CDMA to LTE) Handover Execution


Definition

The counter is used to count the number of successful Incoming


Inter-RAT(GSM to LTE) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-227
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the target eNodeB receives the RRCConnectionReconfigurationComplete message from UE.
Sampling Point 10

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReconfigurationComplete message from UE.

9.7.2.3.6 C373672105 Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure due to RRC
Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 6

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.7.2.3.7 C373672106 Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

9-228
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

After transmission of a S1AP message HandoverRequestAcknowledge


from target eNodeB to MME,the target eNodeB receives the UE CONTEXT
RELEASE COMMAND message indicating handover failure. The target
trigger UE release. Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.7.2.3.8 C373672107 Number of Incoming Inter-RAT(CDMA to LTE) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Other Cause.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HandoverRequestAcknowledge


from target eNodeB to MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.7.2.3.9 C373672108 Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover Preparation


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to CDMA) Handover Preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 12

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the eNodeB to the CDMA,it indicates
the successful preparation of an outgoing inter-eNB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.
9-229

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9.7.2.3.10 C373672109 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to HO
Command Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to HO Command Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 11

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source send HandoverCancel message to the
MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.7.2.3.11 C373672110 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to Dst
Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to destination Preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationfailure
message from the MME. It indicates the handover has failed.Each
HandoverPreparationfailure message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9-230
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.7.2.3.12 C373672111 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.7.2.3.13 C373672112 Number of Successful Outgoing Inter-RAT(LTE to CDMA) Handover Execution


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to CDMA) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 3

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to UTRAN). Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.7.2.3.14 C373672113 Number of Outgoing Inter-RAT(LTE->CDMA)Handover Execution Failure due to


Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA)Handover Execution failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

9-231
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 5

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.7.2.3.15 C373672114 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 7

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.7.2.3.16 C373672115 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-232

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.7.2.3.17 C373672116 Number of Outgoing Inter-RAT(LTE to CDMA) Handover Preparation Failure due to User
Inactivity
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


CDMA) Handover Preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.
Sampling Point 13

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.7.3 LTE-GSM Handover on EUtranRelation


9.7.3.1 Flow Charts and Sampling Points

9-233
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 9-31 Inter-RAT Handover

9-234
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

l
l
l
l
l
l
l
l

Sampling Point 1: The source eNodeB sends the HandoverRequired message to the
MME.
Sampling Point 2: The target eNodeB receives the HandoverRequest message from
the MME.
Sampling Point 3: The source eNodeB receives the HandoverCommand message
from the MME.
Sampling Point 4: The target eNodeB sends the HandoverRequestAcknowledge
message to MME.
Sampling Point 5: The source eNodeB occurs timeout for HandoverCommand
message.
Sampling Point 6: The source eNodeB receives the HandoverPreprationFailure
message from the MME.
Sampling Point 7: The target eNodeB sends the HandoverFailure message to the
MME.
Sampling Point 8: The source eNodeB sends the RRCConnectionReconfiguration
message to UE.

9-235
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

l
l
l
l
l

Sampling
Point
10:
The
target
eNodeB
receives
the
RRCConnectionReconfigurationComplete message from UE.
Sampling
Point
11:
The
target
eNodeB
occurs
timeout
for
RRCConnectionReconfigurationComplete.
Sampling Point 12: The target eNodeB sends the HandoverNotify message to the
MME.
Sampling Point 13: The source eNodeB receives the UEContextReleaseCommand
message from the MME.
Sampling
Point
14:
The
source
eNodeB
occurs
timeout
for
UEContextReleaseCommand message.

Figure 9-32 S1 Handover(2)

Sampling
Point
15:
The
eNodeB
receives
RRCConnectionReestablishmentRequest
message
from
UE
inter-eNB S1 handover.

the
during

9.7.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373682400

Number of Successful Incoming Inter-RAT(GSM to LTE) Handover


Preparation

C373682401

Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure


due to Resource Allocation Fail

9-236
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
3

C373682402

Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure


due to Source Cancel HO

C373682403

Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure


due to Other Reason

C373682404

Number of Successful Incoming Inter-RAT(GSM- to LTE) Handover


Execution

C373682405

Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure


due to RRC Reconfig Complete Timeout

C373682406

Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure


due to Source Cancel HO

C373682407

Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure


due to Other Cause

C373682408

Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover


Preparation

10

C373682409

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to HO Command Timeout

11

C373682410

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to Dst Preparation Failure

12

C373682411

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to Other Reason

13

C373682412

Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover Execution

14

C373682413

Number of Outgoing Inter-RAT(LTE->GSM)Handover Execution Failure due


to Re-estabilshment to Source eNodeB

15

C373682414

Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure


due to UE Context Release Timeout

16

C373682415

Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure


due to Other Cause

17

C373682416

Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure


due to User Inactivity

9.7.3.3 Counter Description


9.7.3.3.1 C373682400 Number of Successful Incoming Inter-RAT(GSM to LTE) Handover Preparation
Definition

The counter is used to count the number of successful incoming


Inter-RAT(GSM to LTE) Handover Preparation.

Sampling Interval

Event triggered
9-237

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends the HandoverRequestAck message to


the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME


to the target eNodeB,the target sends the HANDOVER REQUEST
ACKNOWLEDGE message to the MME indicating the successful
preparation of resources.Each HANDOVER REQUEST ACKNOWLEDGE
message is added to the counter.

Updated

The counter is incremented by 1 when the target eNodeB sends the


HandoverRequestAck message to the MME.

9.7.3.3.2 C373682401 Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure due to Resource
Allocation Fail
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to resource allocation fail.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB sends Handover failure message to the MME
due to admission failures.
Sampling Point 14

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target has no
enough resource then sends the HANDOVER FAILURE message to the
MME indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB sends Handover


failure message to the MME due to admission failures.

9.7.3.3.3 C373682402 Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-238
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from the MME.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target receives
the UE CONTEXT RELEASE COMMAND message from the MME
indicating handover failure.Each the UE CONTEXT RELEASE COMMAND
message is added to the counter.

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from the MME.

9.7.3.3.4 C373682403 Number of Incoming Inter-RAT(GSM- to LTE) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover preparation failures due to other
reason.

Explanation

After receipt of the HandoverRequest message sent by the MME to the


target eNodeB to request the preparation of resources,the target occur
other failures then sends the HANDOVER FAILURE message to the MME
indicating the handover failures.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


preparation failures due to other reason.

9.7.3.3.5 C373682404 Number of Successful Incoming Inter-RAT(GSM- to LTE) Handover Execution


Definition

The counter is used to count the number of successful Incoming


Inter-RAT(GSM to LTE) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the RRCConnectionReconfigurationComplete message from UE.
Sampling Point 4

9-239
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Transmission of a S1AP message UE CONTEXT RELEASE COMMAND


sent from source eNB to the MME, indicating a successful IRAT handover.
Each UE CONTEXT RELEASE COMMAND message received is added to
the counter.

Updated

The counter is incremented by 1 when the target eNodeB receives the


RRCConnectionReconfigurationComplete message from UE.

9.7.3.3.6 C373682405 Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure due to RRC
Reconfig Complete Timeout
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to RRC Reconfig Complete Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB's timer of waiting for the RRCConnectionReconfigurationComplete message expires.
Sampling Point 6

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the timer of monitoring RRCConnectionReconfigurationComplete message expires.The target trigger local UE entity release.

Updated

The counter is incremented by 1 when the target eNodeB's timer of waiting


for the RRCConnectionReconfigurationComplete message expires.

9.7.3.3.7 C373682406 Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure due to Source
Cancel HO
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Source Cancel HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB receives the UEContextReleaseCommand


message from MME.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target receives the UE CONTEXT RELEASE
COMMAND message indicating handover failure.The target trigger UE
release. Each the UE CONTEXT RELEASE COMMAND message is
added to the counter.
9-240

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Updated

The counter is incremented by 1 When the target eNodeB receives the


UEContextReleaseCommand message from MME.

9.7.3.3.8 C373682407 Number of Incoming Inter-RAT(GSM- to LTE) Handover Execution Failure due to Other Cause
Definition

The counter is used to count the number of incoming Inter-RAT(GSM to


LTE) Handover Execution failures due to Other Cause.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the target eNodeB occurs handover execution failures due to other
reason.

Explanation

After transmission of a S1AP message HANDOVER COMMAND from


source eNB to the MME,the target occur other failures then trigger UE
release indicating handover failure.

Updated

The counter is incremented by 1 when the target eNodeB occurs handover


execution failures due to other reason.

9.7.3.3.9 C373682408 Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover Preparation


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to GSM) Handover Preparation.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the RRCConnectionReconfiguration


message to the UE.
Sampling Point 12

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover from the eNodeB to the GSM,it indicates the
successful preparation of an outgoing inter-eNB handover. Each
RRCConnectionReconfiguration message transimtted is added to the
counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


RRCConnectionReconfiguration message to the UE.

9-241
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.7.3.3.10 C373682409 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to HO
Command Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Preparation failures due to HO Command Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the HandoverCommand


message expires.
Sampling Point 11

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the timer of monitoring the HandoverCommand
message expires. Then the source send HandoverCancel message to the
MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the HandoverCommand message expires.

9.7.3.3.11 C373682410 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to Dst
Preparation Failure
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE


to GSM) Handover Preparation failures due to destination Preparation
failures.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the Handover Preparation failure


message from the MME.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source receives the HandoverPreparationfailure
message from the MME. It indicates the handover has failed.Each
HandoverPreparationfailure message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


Handover Preparation failure message from the MME.

9-242
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.7.3.3.12 C373682411 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to Other
Reason
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Preparation failures due to Other Reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover preparation failures due to


other reason.

Explanation

After transmission of the HandoverRequired message from the source


eNodeB to the MME, the source occurs other failures. Then the source
send HandoverCancel message to the MME. It indicates the handover fails.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover preparation failures due to other reason.

9.7.3.3.13 C373682412 Number of Successful Outgoing Inter-RAT(LTE to GSM) Handover Execution


Definition

The counter is used to count the number of successful outgoing


Inter-RAT(LTE to GSM) Handover Execution.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release message


from the MME.
Sampling Point 3

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to UTRAN). Each UE CONTEXT RELEASE
COMMAND message received is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


UE Context Release message from the MME.

9.7.3.3.14 C373682413 Number of Outgoing Inter-RAT(LTE->GSM)Handover Execution Failure due to


Re-estabilshment to Source eNodeB
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM)Handover Execution failures due to the UE Reback to Source Cell.

Sampling Interval

Event triggered

9-243
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the RRCConnectionReestablishmentRequest message from the UE.
Sampling Point 5

Explanation

Receipt of a RRCConnectionReestablishmentRequest message by


the source eNodeB from the UE during handover, the HANDOVER
CANCEL message is sent to by the source eNodeB to MME. Each this
RRCConnectionReestablishmentRequest message received is added to
the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the


RRCConnectionReestablishmentRequest message from the UE.

9.7.3.3.15 C373682414 Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure due to UE
Context Release Timeout
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE


to GSM) Handover Execution failures due to the UE Context Release
Timeout.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB's timer of waiting for the UEContextRelease


message expires.
Sampling Point 7

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the timer of monitoring the
message expires.Then the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB's timer of


waiting for the UEContextRelease message expires.

9.7.3.3.16 C373682415 Number of Outgoing Inter-RAT(LTE to GSM) Handover Execution Failure due to Other
Cause
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Execution failures due to other reason.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-244

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB occurs handover execution failures due to other
reason.

Explanation

Before receipt of a S1AP message UE CONTEXT RELEASE COMMAND


sent from the MME to the source eNodeB,the other reason occurs.Then
the source trigger UE release.

Updated

The counter is incremented by 1 when the source eNodeB occurs


handover execution failures due to other reason.

9.7.3.3.17 C373682416 Number of Outgoing Inter-RAT(LTE to GSM) Handover Preparation Failure due to User
Inactivity
Definition

The counter is used to count the number of outgoing Inter-RAT(LTE to


GSM) Handover Preparation failures due to user inactive.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When UE's state detected by eNodeB is "user inactive" in source eNodeB


during handover preparation.

Explanation

Before transmission of the RRCConnectionReconfiguration message to


UE triggering the handover from the source eNodeB to the target eNodeB,
the source eNodeB detects the user inactive. The HANDOVER CANCEL
message is sent to by the eNodeB to the MME. Each the condition is
added to the counter.

Updated

The counter is incremented by 1 when UE's state detected by eNodeB is


"user inactive" in source eNodeB during handover preparation.

9.8 SRVCC Handover


9.8.1 LTE-UTRAN SRVCC Handover
9.8.1.1 Flow Charts and Sampling Points
No chart.

9-245
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.8.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373661817

Number of Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover


Preparation Request

C373661818

Number of Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover


Preparation Failure

C373661819

Number of Successful Outgoing Inter-RAT(LTE to UTRAN) SRVCC


Handover Execution

C373661820

Number of Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover Execution


Failure

9.8.1.3 Counter Description


9.8.1.3.1 C373661817 Number of Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover Preparation Request
Definition

The counter is used to count the number of attempted outgoing handover


preparation for SRVCC from LTE to UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the MobilityFromEUTRACommand


message to the UE.

Explanation

Transmission of the MobilityFromEUTRACommand message or the


HandoverFromEUTRAPreparationRequest message from the serving eNB
to the UE indicating the attempt of an outgoing handover for SRVCC
from EUTRAN to UTRAN. Each MobilityFromEUTRACommand message
transimtted is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


MobilityFromEUTRACommand message for SRVCC to the UE.

9.8.1.3.2 C373661818 Number of Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover Preparation Failure
Definition

The counter is used to count the number of outgoing handover execution


failures for SRVCC from LTE to UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-246

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the HANDOVER PREPARATION


FAILURE message or the RRCConnectionReestablishmentRequest or
occurs timeout indicating SRVCC handover preparation failures.

Explanation

Receipt of the HANDOVER PREPARATION FAILURE message by The


eNodeB or timeout etc. it indicates the handover preparation failure. If the
handover is SRVCC, the failure is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives


the HANDOVER PREPARATION FAILURE message or the
RRCConnectionReestablishmentRequest or occurs timeout indicating
SRVCC handover preparation failures.

9.8.1.3.3 C373661819 Number of Successful Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover Execution
Definition

The counter is used to count the number of successful outgoing handover


execution for SRVCC from LTE to UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release Command


message from the MME.

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates
a successful IRAT handover(LTE to UTRAN) for SRVCC. Each UE
CONTEXT RELEASE COMMAND message received is added to the
counter.

Updated

The counter is incremented by 1 when the source eNodeB receives the UE


Context Release Command message from the MME.

9.8.1.3.4 C373661820 Number of Outgoing Inter-RAT(LTE to UTRAN) SRVCC Handover Execution Failure
Definition

The counter is used to count the number of outgoing handover execution


failures for SRVCC from LTE to UTRAN.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source cell handover fails for SRVCC from LTE to UTRAN.

9-247
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Not receipt of the RRCConnectionReestablishmentComplete message by


The eNodeB or timeout etc. it indicates the handover execution failure. If
the handover cause is SRVCC from LTE to UTRAN, the failure is added to
the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


fails for SRVCC from LTE to UTRAN.

9.8.2 LTE-GSM SRVCC Handover


9.8.2.1 Flow Charts and Sampling Points
No chart.

9.8.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373682417

Number of Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Preparation


Request

C373682418

Number of Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Preparation


Failure

C373682419

Number of Successful Outgoing Inter-RAT(LTE to GSM) SRVCC Handover


Execution

C373682420

Number of Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Execution


Failure

9.8.2.3 Counter Description


9.8.2.3.1 C373682417 Number of Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Preparation Request
Definition

The counter is used to count the number of attempted outgoing handover


preparation for SRVCC from LTE to GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB sends the MobilityFromEUTRACommand


message to the UE.

9-248
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Transmission of the MobilityFromEUTRACommand message or the


HandoverFromEUTRAPreparationRequest message from the serving eNB
to the UE indicating the attempt of an outgoing handover for SRVCC from
EGSM to GSM. Each MobilityFromEUTRACommand message transimtted
is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB sends the


MobilityFromEUTRACommand message for SRVCC to the UE.

9.8.2.3.2 C373682418 Number of Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Preparation Failure
Definition

The counter is used to count the number of outgoing handover execution


failures for SRVCC from LTE to GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the HANDOVER PREPARATION


FAILURE message or the RRCConnectionReestablishmentRequest or
occurs timeout indicating SRVCC handover preparation failures.

Explanation

Receipt of the HANDOVER PREPARATION FAILURE message by The


eNodeB or timeout etc. it indicates the handover preparation failure. If the
handover is SRVCC, the failure is added to the counter.

Updated

The counter is incremented by 1 when the source eNodeB receives


the HANDOVER PREPARATION FAILURE message or the
RRCConnectionReestablishmentRequest or occurs timeout indicating
SRVCC handover preparation failures.

9.8.2.3.3 C373682419 Number of Successful Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Execution
Definition

The counter is used to count the number of successful outgoing handover


execution for SRVCC from LTE to GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source eNodeB receives the UE Context Release Command


message from the MME.

Explanation

When eNodeB receives a S1AP message UE CONTEXT RELEASE


COMMAND sent from the MME to the source eNodeB, it indicates a
successful IRAT handover(LTE to GSM) for SRVCC. Each UE CONTEXT
RELEASE COMMAND message received is added to the counter.
9-249

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the source eNodeB receives the UE


Context Release Command message from the MME.

9.8.2.3.4 C373682420 Number of Outgoing Inter-RAT(LTE to GSM) SRVCC Handover Execution Failure
Definition

The counter is used to count the number of outgoing handover execution


failures for SRVCC from LTE to GSM.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the source cell handover fails for SRVCC from LTE to GSM.

Explanation

Not receipt of the RRCConnectionReestablishmentComplete message by


The eNodeB or timeout etc. it indicates the handover execution failure. If
the handover cause is SRVCC from LTE to GSM, the failure is added to
the counter.

Updated

The counter is incremented by 1 when the source cell handover execution


fails for SRVCC from LTE to GSM.

9.9 RSRP and RSRQ


9.9.1 RSRP and RSRQ of the Serving Cell
9.9.1.1 Flow Charts and Sampling Points
Figure 9-33 RSRP and RSRQ of the Serving Cell

Sampling Point 1: When the eNodeB receives the MeasurementReport message from
UE, eNodeB judges to trigger handover.

9-250
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373743400

Maximum of RSRP Value of Serving Cell

C373743401

Minimum of RSRP Value of Serving Cell

C373743402

Average of RSRP Value of Serving Cell

C373743403

Sum of RSRP Value in the range of -140 to -91 of Serving Cell

C373743404

Sum of RSRP Value in the range of -90 to -43 of Serving Cell

C373743405

Report Times of RSRP Value in the range of -140 to -121 of Serving Cell

C373743406

Report Times of RSRP Value in the range of -120 to -116 of Serving Cell

C373743407

Report Times of RSRP Value in the range of -115 to -111 of Serving Cell

C373743408

Report Times of RSRP Value in the range of -110 to -106 of Serving Cell

10

C373743409

Report Times of RSRP Value in the range of -105 to -101 of Serving Cell

11

C373743410

Report Times of RSRP Value in the range of -100 to -96 of Serving Cell

12

C373743411

Report Times of RSRP Value in the range of -95 to -91 of Serving Cell

13

C373743412

Report Times of RSRP Value in the range of -90 to -86 of Serving Cell

14

C373743413

Report Times of RSRP Value in the range of -85 to -81 of Serving Cell

15

C373743414

Report Times of RSRP Value in the range of -80 to -76 of Serving Cell

16

C373743415

Report Times of RSRP Value in the range of -75 to -71 of Serving Cell

17

C373743416

Report Times of RSRP Value in the range of -70 to -61 of Serving Cell

18

C373743417

Report Times of RSRP Value in the range of -60 to -43 of Serving Cell

19

C373743500

Maximum of RSRQ Value of Serving Cell

20

C373743501

Minimum of RSRQ Value of Serving Cell

21

C373743502

Average of RSRQ Value of Serving Cell

22

C373743503

Linear Average of RSRQ Value of Serving Cell

23

C373743504

Report Times of RSRQ Value in the range of -20 to -18 of Serving Cell

24

C373743505

Report Times of RSRQ Value in the range of -17 to -15 of Serving Cell

25

C373743506

Report Times of RSRQ Value in the range of -14 to -12 of Serving Cell

26

C373743507

Report Times of RSRQ Value in the range of -11 to -9 of Serving Cell

27

C373743508

Report Times of RSRQ Value in the range of -8 to -6 of Serving Cell

28

C373743509

Report Times of RSRQ Value in the range of -5 to -3 of Serving Cell

9-251
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.1.3 Counter Description


9.9.1.3.1 C373743400 Maximum of RSRP Value of Serving Cell
Definition

The counter is used to count the maximum RSRP value of the serving cell
reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Maximum

Unit

dBm

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1.

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
maximum of all collected value.

Updated

The counter is replaced with the current value when the current RSRP
value is larger than the prior at sampling point.

9.9.1.3.2 C373743401 Minimum of RSRP Value of Serving Cell


Definition

The counter is used to count the minimum RSRP value of the serving cell
reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Minimum

Unit

dBm

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1.

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
minimum of all collected value.

Updated

The counter is replaced with the current value when the current RSRP
value is smaller than the prior at sampling point.

9.9.1.3.3 C373743402 Average of RSRP Value of Serving Cell


Definition

The counter is used to count the average RSRP value of the serving cell
reported in the UE measurement reports that triggered HO.
9-252

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Average

Unit

dBm

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRP value, and
then dividing the sum by the measurement period.

9.9.1.3.4 C373743403 Sum of RSRP Value in the range of -140 to -91 of Serving Cell
Definition

The counter is used to count the average RSRP linear value of quality of
the serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

1E-14mW

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRP linear value,
and then dividing the sum by the measurement period.

9.9.1.3.5 C373743404 Sum of RSRP Value in the range of -90 to -43 of Serving Cell
Definition

The counter is used to count the average RSRP linear value of quality of
the serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

1E-9mW

Measurement Object

EUtran Relation
9-253

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRP linear value,
and then dividing the sum by the measurement period.

9.9.1.3.6 C373743405 Report Times of RSRP Value in the range of -140 to -121 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-140 to -121)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -140 and -121.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-140 to -121).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -140
and -121.

9.9.1.3.7 C373743406 Report Times of RSRP Value in the range of -120 to -116 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-120 to -116)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-254
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -120 and -116.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-120 to -116).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -120
and -116.

9.9.1.3.8 C373743407 Report Times of RSRP Value in the range of -115 to -111 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-115 to -111)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -115 and -111.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-115 to -111).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -115
and -111.

9.9.1.3.9 C373743408 Report Times of RSRP Value in the range of -110 to -106 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-110 to -106)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-255
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -110 and -106.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-110 to -106).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -110
and -106.

9.9.1.3.10 C373743409 Report Times of RSRP Value in the range of -105 to -101 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-105 to -101)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -105 and -101.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-105 to -101).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -105
and -101.

9.9.1.3.11 C373743410 Report Times of RSRP Value in the range of -100 to -96 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-100 to -96)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

9-256
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -100 and -96.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-100 to -96).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -100
and -96.

9.9.1.3.12 C373743411 Report Times of RSRP Value in the range of -95 to -91 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-95 to -91)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -95 and -91.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-95 to -91).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -95
and -91.

9.9.1.3.13 C373743412 Report Times of RSRP Value in the range of -90 to -86 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-90 to -86)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

9-257
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -90 and -86.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-90 to -86).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -90
and -86.

9.9.1.3.14 C373743413 Report Times of RSRP Value in the range of -85 to -81 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-85 to -81)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -85 and -81.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-85 to -81).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -85
and -81.

9.9.1.3.15 C373743414 Report Times of RSRP Value in the range of -80 to -76 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-80 to -76)of the
serving cell reported in the UE measurement reports that triggered HO.

9-258
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -80 and -76.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-80 to -76).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -80
and -76.

9.9.1.3.16 C373743415 Report Times of RSRP Value in the range of -75 to -71 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-75 to -71)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -75 and -71.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-75 to -71).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -75
and -71.

9-259
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.1.3.17 C373743416 Report Times of RSRP Value in the range of -70 to -61 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-70 to -61)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -70 and -61.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-70 to -61).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -70
and -61.

9.9.1.3.18 C373743417 Report Times of RSRP Value in the range of -60 to -43 of Serving Cell
Definition

The counter is used to count the times of RSRP value (-60 to -43)of the
serving cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
serving cell in the message ranges between -60 and -43.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRP value (-60 to -43).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of serving cell in the message ranges between -60
and -43.
9-260

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.1.3.19 C373743500 Maximum of RSRQ Value of Serving Cell


Definition

The counter is used to count the maximum RSRQ value of quality of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Maximum

Unit

dB

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
maximum of all collected value.

Updated

The counter is replaced with the current value when the current RSRQ
value is larger than the prior at sampling point.

9.9.1.3.20 C373743501 Minimum of RSRQ Value of Serving Cell


Definition

The counter is used to count the minimum RSRQ value of quality of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Minimum

Unit

dB

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
minimum of all collected value.

Updated

The counter is replaced with the current value when the current RSRQ
value is smaller than the prior at sampling point.

9.9.1.3.21 C373743502 Average of RSRQ Value of Serving Cell


Definition

The counter is used to count the average RSRQ value of quality of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered
9-261

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Average

Unit

dB

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRQ value, and
then dividing the sum by the measurement period.

9.9.1.3.22 C373743503 Linear Average of RSRQ Value of Serving Cell


Definition

The counter is used to count the linear average RSRQ value of quality of
the serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Average

Unit

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
linear average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRQ linear value,
and then dividing the sum by the measurement period.

9.9.1.3.23 C373743504 Report Times of RSRQ Value in the range of -20 to -18 of Serving Cell
Definition

The counter is used to count the times of RSRQ value (-20 to -18)of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

9-262
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
serving cell in the message ranges between -20 and -18.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRQ value (-20 to -18).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of serving cell in the message ranges between -20
and -18.

9.9.1.3.24 C373743505 Report Times of RSRQ Value in the range of -17 to -15 of Serving Cell
Definition

The counter is used to count the times of RSRQ value (-17 to -15)of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
serving cell in the message ranges between -17 and -15.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRQ value (-17 to -15).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of serving cell in the message ranges between -17
and -15.

9.9.1.3.25 C373743506 Report Times of RSRQ Value in the range of -14 to -12 of Serving Cell
Definition

The counter is used to count the times of RSRQ value (-14 to -12)of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

9-263
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
serving cell in the message ranges between -14 and -12.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRQ value (-14 to -12).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of serving cell in the message ranges between -14
and -12.

9.9.1.3.26 C373743507 Report Times of RSRQ Value in the range of -11 to -9 of Serving Cell
Definition

The counter is used to count the times of RSRQ value (-11 to -9)of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
serving cell in the message ranges between -11 and -9.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRQ value (-11 to -9).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of serving cell in the message ranges between -11
and -9.

9.9.1.3.27 C373743508 Report Times of RSRQ Value in the range of -8 to -6 of Serving Cell
Definition

The counter is used to count the times of RSRQ value (-8 to -6)of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

9-264
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to triggerintra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
serving cell in the message ranges between -8 and -6.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRQ value (-8 to -6).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of serving cell in the message ranges between -8
and -6.

9.9.1.3.28 C373743509 Report Times of RSRQ Value in the range of -5 to -3 of Serving Cell
Definition

The counter is used to count the times of RSRQ value (-5 to -3)of the
serving cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
serving cell in the message ranges between -5 and -3.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the serving cell in the message is collected. The counter records the
number of the RSRQ value (-5 to -3).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of serving cell in the message ranges between -5
and -3.

9-265
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.2 RSRP and RSRQ of the Neighboring Cell


9.9.2.1 Flow Charts and Sampling Points
Figure 9-34 RSRP and RSRQ of the Neighboring Cell

Sampling Point 1: When the eNodeB receives the MeasurementReport message from
UE, eNodeB judges to trigger handover.

9.9.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373743418

Maximum of RSRP Value of Target Cell

C373743419

Minimum of RSRP Value of Target Cell

C373743420

Average of RSRP Value of Target Cell

C373743421

Sum of RSRP Value in the range of -140 to -91 of Target Cell

C373743422

Sum of RSRP Value in the range of -90 to -43 of Target Cell

C373743423

Report Times of RSRP Value in the range of -140 to -121 of Target Cell

C373743424

Report Times of RSRP Value in the range of -120 to -116 of Target Cell

C373743425

Report Times of RSRP Value in the range of -115 to -111 of Target Cell

C373743426

Report Times of RSRP Value in the range of -110 to -106 of Target Cell

10

C373743427

Report Times of RSRP Value in the range of -105 to -101 of Target Cell

11

C373743428

Report Times of RSRP Value in the range of -100 to -96 of Target Cell

12

C373743429

Report Times of RSRP Value in the range of -95 to -91 of Target Cell

13

C373743430

Report Times of RSRP Value in the range of -90 to -86 of Target Cell

14

C373743431

Report Times of RSRP Value in the range of -85 to -81 of Target Cell

15

C373743432

Report Times of RSRP Value in the range of -80 to -76 of Target Cell

16

C373743433

Report Times of RSRP Value in the range of -75 to -71 of Target Cell
9-266

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
17

C373743434

Report Times of RSRP Value in the range of -70 to -61 of Target Cell

18

C373743435

Report Times of RSRP Value in the range of -60 to -43 of Target Cell

19

C373743510

Maximum of RSRQ Value of Target Cell

20

C373743511

Minimum of RSRQ Value of Target Cell

21

C373743512

Average of RSRQ Value of Target Cell

22

C373743513

Linear Average of RSRQ Value of Target Cell

23

C373743514

Report Times of RSRQ Value in the range of -20 to -18 of Target Cell

24

C373743515

Report Times of RSRQ Value in the range of -17 to -15 of Target Cell

25

C373743516

Report Times of RSRQ Value in the range of -14 to -12 of Target Cell

26

C373743517

Report Times of RSRQ Value in the range of -11 to -9 of Target Cell

27

C373743518

Report Times of RSRQ Value in the range of -8 to -6 of Target Cell

28

C373743519

Report Times of RSRQ Value in the range of -5 to -3 of Target Cell

9.9.2.3 Counter Description


9.9.2.3.1 C373743418 Maximum of RSRP Value of Target Cell
Definition

The counter is used to count the maximum RSRP value of quality of


the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Maximum

Unit

dBm

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1.

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
maximum of all collected value.

Updated

The counter is replaced with the current value when the current RSRP
value is larger than the prior at sampling point.

9-267
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.2.3.2 C373743419 Minimum of RSRP Value of Target Cell


Definition

The counter is used to count the minimum RSRP value of quality of


the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Minimum

Unit

dBm

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1.

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
minimum of all collected value.

Updated

The counter is replaced with the current value when the current RSRP
value is smaller than the prior at sampling point.

9.9.2.3.3 C373743420 Average of RSRP Value of Target Cell


Definition

The counter is used to count the average RSRP value of quality of


the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Average

Unit

dBm

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1.

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRP value, and
then dividing the sum by the measurement period.

9-268
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.2.3.4 C373743421 Sum of RSRP Value in the range of -140 to -91 of Target Cell
Definition

The counter is used to count the average RSRP linear value of quality of
the neigbor cell that triggered HO reported in the UE measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

1E-14mW

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRP linear value,
and then dividing the sum by the measurement period.

9.9.2.3.5 C373743422 Sum of RSRP Value in the range of -90 to -43 of Target Cell
Definition

The counter is used to count the average RSRP linear value of quality
of the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

1E-9mW

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRP linear value,
and then dividing the sum by the measurement period.

9.9.2.3.6 C373743423 Report Times of RSRP Value in the range of -140 to -121 of Target Cell
Definition

The counter is used to count the times of RSRP value (-140 to -121)of the
neigbor cell reported in the UE measurement reports that triggered HO.
9-269

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -140 and -121.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-140 to -121).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -140
and -121.

9.9.2.3.7 C373743424 Report Times of RSRP Value in the range of -120 to -116 of Target Cell
Definition

The counter is used to count the times of RSRP value (-120 to -116)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -120 and -116.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-120 to -116).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -120
and -116.

9-270
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.2.3.8 C373743425 Report Times of RSRP Value in the range of -115 to -111 of Target Cell
Definition

The counter is used to count the times of RSRP value (-115 to -111)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -115 and -111.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-115 to -111).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -115
and -111.

9.9.2.3.9 C373743426 Report Times of RSRP Value in the range of -110 to -106 of Target Cell
Definition

The counter is used to count the times of RSRP value (-110 to -106)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -110 and -106.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-110 to -106).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -110
and -106.
9-271

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.2.3.10 C373743427 Report Times of RSRP Value in the range of -105 to -101 of Target Cell
Definition

The counter is used to count the times of RSRP value (-105 to -101)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -105 and -101.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-105 to -101).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -105
and -101.

9.9.2.3.11 C373743428 Report Times of RSRP Value in the range of -100 to -96 of Target Cell
Definition

The counter is used to count the times of RSRP value (-100 to -96)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -100 and -96.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-100 to -96).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -100
and -96.
9-272

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.2.3.12 C373743429 Report Times of RSRP Value in the range of -95 to -91 of Target Cell
Definition

The counter is used to count the times of RSRP value (-95 to -91)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -95 and -91.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-95 to -91).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -95
and -91.

9.9.2.3.13 C373743430 Report Times of RSRP Value in the range of -90 to -86 of Target Cell
Definition

The counter is used to count the times of RSRP value (-90 to -86)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -90 and -86.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-90 to -86).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -90
and -86.
9-273

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.2.3.14 C373743431 Report Times of RSRP Value in the range of -85 to -81 of Target Cell
Definition

The counter is used to count the times of RSRP value (-85 to -81)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -85 and -81.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-85 to -81).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -85
and -81.

9.9.2.3.15 C373743432 Report Times of RSRP Value in the range of -80 to -76 of Target Cell
Definition

The counter is used to count the times of RSRP value (-80 to -76)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -80 and -76.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-80 to -76).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -80
and -76.
9-274

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.2.3.16 C373743433 Report Times of RSRP Value in the range of -75 to -71 of Target Cell
Definition

The counter is used to count the times of RSRP value (-75 to -71)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -75 and -71.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-75 to -71).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -75
and -71.

9.9.2.3.17 C373743434 Report Times of RSRP Value in the range of -70 to -61 of Target Cell
Definition

The counter is used to count the times of RSRP value (-70 to -61)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -70 and -61.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-70 to -61).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -70
and -61.
9-275

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.2.3.18 C373743435 Report Times of RSRP Value in the range of -60 to -43 of Target Cell
Definition

The counter is used to count the times of RSRP value (-60 to -43)of the
neigbor cell reported in the UE measurement reports that triggered HO.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRP value of
neigbor cell in the message ranges between -60 and -43.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRP value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRP value (-60 to -43).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRP value of neigbor cell in the message ranges between -60
and -43.

9.9.2.3.19 C373743510 Maximum of RSRQ Value of Target Cell


Definition

The counter is used to count the maximum RSRQ value of quality of


the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Maximum

Unit

dB

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
maximum of all collected value.

Updated

The counter is replaced with the current value when the current RSRQ
value is larger than the prior at sampling point.

9-276
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.2.3.20 C373743511 Minimum of RSRQ Value of Target Cell


Definition

The counter is used to count the minimum RSRQ value of quality of


the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Minimum

Unit

dB

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
minimum of all collected value.

Updated

The counter is replaced with the current value when the current RSRQ
value is smaller than the prior at sampling point.

9.9.2.3.21 C373743512 Average of RSRQ Value of Target Cell


Definition

The counter is used to count the average RSRQ value of quality of


the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Average

Unit

dB

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
average of all collected value.

Updated

The counter is updated by accumulating all the sample RSRQ value(dbm),


and then dividing the sum by the measurement period.

9-277
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.9.2.3.22 C373743513 Linear Average of RSRQ Value of Target Cell


Definition

The counter is used to count the linear average RSRQ value of quality
of the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Average

Unit

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
linear average of all collected value.

Updated

The counter is updated by accumulating all the sample linear RSRQ value,
and then dividing the sum by the measurement period.

9.9.2.3.23 C373743514 Report Times of RSRQ Value in the range of -20 to -18 of Target Cell
Definition

The counter is used to count the times of RSRQ value (-20 to -18)of
the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
neigbor cell in the message ranges between -20 and -18.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRQ value (-20 to -18).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of neigbor cell in the message ranges between -20
and -18.

9-278
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.9.2.3.24 C373743515 Report Times of RSRQ Value in the range of -17 to -15 of Target Cell
Definition

The counter is used to count the times of RSRQ value (-17 to -15)of
the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
neigbor cell in the message ranges between -17 and -15.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRQ value (-17 to -15).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of neigbor cell in the message ranges between -17
and -15.

9.9.2.3.25 C373743516 Report Times of RSRQ Value in the range of -14 to -12 of Target Cell
Definition

The counter is used to count the times of RSRQ value (-14 to -12)of
the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
neigbor cell in the message ranges between -14 and -12.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRQ value (-14 to -12).

9-279
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of neigbor cell in the message ranges between -14
and -12.

9.9.2.3.26 C373743517 Report Times of RSRQ Value in the range of -11 to -9 of Target Cell
Definition

The counter is used to count the times of RSRQ value (-11 to -9)of
the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
neigbor cell in the message ranges between -11 and -9.
Sampling Point 1

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRQ value (-11 to -9).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of neigbor cell in the message ranges between -11
and -9.

9.9.2.3.27 C373743518 Report Times of RSRQ Value in the range of -8 to -6 of Target Cell
Definition

The counter is used to count the times of RSRQ value (-8 to -6)of
the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
neigbor cell in the message ranges between -8 and -6.
Sampling Point 1.

9-280
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRQ value (-8 to -6).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of neigbor cell in the message ranges between -8
and -6.

9.9.2.3.28 C373743519 Report Times of RSRQ Value in the range of -5 to -3 of Target Cell
Definition

The counter is used to count the times of RSRQ value (-5 to -3)of
the neigbor cell that triggered HO (target HO cell) reported in the UE
measurement reports.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

EUtran Relation

Sampling Point

When the eNodeB judges to trigger intra-RAT handover after receiving


the MeasurementReport message from the UE, and the RSRQ value of
neigbor cell in the message ranges between -5 and -3.
Sampling Point 1.

Explanation

When the eNodeB judges to trigger intra-RAT handover after receiving the
MeasurementReport message from the UE, the RSRQ value of the quality
of the neigbor cell in the message is collected. The counter records the
number of the RSRQ value (-5 to -3).

Updated

The counter is incremented by 1 when the eNodeB triggers intra-RAT


handover after receiving the MeasurementReport message from the UE,
and the RSRQ value of neigbor cell in the message ranges between -5
and -3.

9.10 Handover Time


9.10.1 Flow Charts and Sampling Points

9-281
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 9-35 X2 Handover Time

l
l

Sampling Point 1: When the source eNodeB sends the HandoverRequest message
to target eNodeB.
Sampling Point 2: When the source eNodeB receives the UEContextRelease message to target eNodeB.

Figure 9-36 S1 or Inter-RAT Handover Time

l
l

Sampling Point 3: When the source eNodeB sends the HandoverRequired message
to target eNodeB.
Sampling
Point
4:
When
the
source
eNodeB
receives
the
UEContextReleaseCommand message to target eNodeB.

9.10.2 Counter List


NO.

Counter

Counter Name

Number
1

C373485130

Mean Handover Camping Duration

C373485131

Number of Short Handover

C373485132

Number of UE Handover

9-282
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

9.10.3 Counter Description


9.10.3.1 C373485130 Mean Handover Camping Duration
Definition

The counter is used to count the average handover resident time.

Sampling Interval

Event triggered

Counter Type

Average

Unit

ms

Measurement Object

Cell

Sampling Point

When a UE successfully enter into the target cell from source cell via
handover,record the start time. When the UE again successfully get out
the cell via handover, record the end time. The handover resident time is
equal to the interval from the start to the end.

Explanation

The handover resident time indicates the UE staying time in a cell through
handover.

Updated

The counter is updated by arithmetic mean of the handover resident time


among sampling points.

9.10.3.2 C373485131 Number of Short Handover


Definition

The counter is used to count the number of handover resident time short
threshold.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When a UE handover resident time is less than the configuration threshold.

Explanation

The short handover indicates the handover whose resident time is


excessively short, in which the threshold configuration is available. This
counter can be applied to measure the condition of system "ping pang"
handover.

Updated

The counter is incremented by 1 when a UE handover resident time is


less than the configuration threshold.

9.10.3.3 C373485132 Number of UE Handover


Definition

The counter is used to count the total number of successful handover.

Sampling Interval

Event triggered
9-283

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When a UE successfully enter into the target cell from source cell via
handover and again successfully get out the cell.

Explanation

Transmission at the cell in target eNB of UE CONTEXT RELEASE over the


X2 to the source eNodeB following a successful handover, or if handover is
performed via S1, Transmission of UE CONTEXT RELEASE COMMAND
at the target eNodeB following a successful handover. Receipt at the
source eNodeB of UE CONTEXT RELEASE over the X2 from the target
eNodeB following a successful handover, or if handover is performed
via S1, receipt of UE CONTEXT RELEASE COMMAND at the source
eNodeB following a successful handover. The measurent also includes
intra-eNB handover.

Updated

The counter is incremented by 1 when a UE successfully enter into the


target cell from source cell via handover and again successfully get out
the cell.

9.11 DRX Handover


9.11.1 Flow Charts and Sampling Points
Refer to:
l
l
l

Figure 8-1 Intra-eNB Handover


Figure 8-2 X2 Handover(1), Figure 8-3 X2 Handover(2)
Figure 8-4 S1 Handover(1), Figure 8-5 S1 Handover(2)

9.11.2 Counter List


NO.

Counter

Counter Name

Number
1

C373485181

Attempted Outgoing Intra-frequency Handovers with DRX

C373485182

Successful Outgoing Intra-frequency Handovers with DRX

C373485183

Attempted Outgoing Intra-frequency Handovers Non-DRX

C373485184

Successful Outgoing Intra-frequency Handovers Non-DRX

C373485185

Attempted Outgoing Inter-frequency Handovers with DRX

C373485186

Successful Outgoing Inter-frequency Handovers with DRX

C373485187

Attempted Outgoing Inter-frequency Handovers Non-DRX


9-284

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

NO.

Counter

Counter Name

Number
8

C373485188

Successfu Outgoing Inter-frequency Handovers Non-DRX

9.11.3 Counter Description


9.11.3.1 C373485181 Attempted Outgoing Intra-frequency Handovers with DRX
Definition

The counter is used to count the number of attempted outgoing intra-freq


handovers when DRX is used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfigurationmessage to UE.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover, indicating the attempt of an outgoing handover
when DRX is used.

Updated

The counter is incremented by 1 when the opening of "DRX" and the


Frequency of source cell and target cell are same.

9.11.3.2 C373485182 Successful Outgoing Intra-frequency Handovers with DRX


Definition

The counter is used to count the number of successful outgoing intra-freq


handovers when DRX is used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReconfigurationComplete message from UE in intra-eNB handover.
When the source eNodeB receives the UEContextRelease message from
the target eNodeB in inter-eNB X2 handover.
When the source eNodeB receives the UEContextReleaseCommand
message from the MME in inter-eNB S1 handover.

9-285
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target eNB, indicating a successful outgoing
intra-eNB handover when DRX is used, or receipt at the source eNB of
UE CONTEXT RELEASE over the X2 from the target eNB following a
successful handover when DRX is used, or if handover is performed via
S1, receipt of UE CONTEXT RELEASE COMMAND at the source eNB
following a successful handover when DRX is used.

Updated

The counter is incremented by 1 when the closing of "DRX" and the


Frequency of source cell and target cell are same.

9.11.3.3 C373485183 Attempted Outgoing Intra-frequency Handovers Non-DRX


Definition

The counter is used to count the number of attempted outgoing intra-freq


handovers when DRX is not used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfigurationmessage to UE.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover, indicating the attempt of an outgoing handover
when DRX is not used.

Updated

The counter is incremented by 1 when the closing of "DRX" and the


Frequency of source cell and target cell are same.

9.11.3.4 C373485184 Successful Outgoing Intra-frequency Handovers Non-DRX


Definition

The counter is used to count the number of successful outgoing intra-freq


handovers when DRX is not used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-286
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Sampling Point

When the source eNodeB receives the RRCConnectionReconfigurationComplete message from UE in intra-eNB handover.
When the source eNodeB receives the UEContextRelease message from
the target eNodeB in inter-eNB X2 handover.
When the source eNodeB receives the UEContextReleaseCommand
message from the MME in inter-eNB S1 handover.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target eNB, indicating a successful outgoing intra-eNB
handover when DRX is not used when DRX is not used, or receipt at the
source eNB of UE CONTEXT RELEASE over the X2 from the target eNB
following a successful handover when DRX is not used, or if handover is
performed via S1, receipt of UE CONTEXT RELEASE COMMAND at the
source eNB following a successful handoverwhen DRX is not used.

Updated

The counter is incremented by 1 when the opening of "DRX" and the


Frequency of source cell and target cell are same.

9.11.3.5 C373485185 Attempted Outgoing Inter-frequency Handovers with DRX


Definition

The counter is used to count the number of attempted outgoing inter-freq


handovers when DRX is used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfigurationmessage to UE.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover, indicating the attempt of an outgoing handover
when DRX is used.

Updated

The counter is incremented by 1 when the opening of "DRX" and the


Frequency of source cell and target cell are not same.

9.11.3.6 C373485186 Successful Outgoing Inter-frequency Handovers with DRX


Definition

The counter is used to count the number of successful outgoing inter-freq


handovers when DRX is used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times
9-287

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReconfigurationComplete message from UE in intra-eNB handover.
When the source eNodeB receives the UEContextRelease message from
the target eNodeB in inter-eNB X2 handover.
When the source eNodeB receives the UEContextReleaseCommand
message from the MME in inter-eNB S1 handover.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target eNB, indicating a successful outgoing
intra-eNB handover when DRX is used, or receipt at the source eNB of
UE CONTEXT RELEASE over the X2 from the target eNB following a
successful handover when DRX is used, or if handover is performed via
S1, receipt of UE CONTEXT RELEASE COMMAND at the source eNB
following a successful handover when DRX is used.

Updated

The counter is incremented by 1 when the closing of "DRX" and the


Frequency of source cell and target cell are not same.

9.11.3.7 C373485187 Attempted Outgoing Inter-frequency Handovers Non-DRX


Definition

The counter is used to count the number of attempted outgoing inter-freq


handovers when DRX is not used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfigurationmessage to UE.

Explanation

Transmission of the RRCConnectionReconfiguration message to UE


triggering the handover, indicating the attempt of an outgoing handover
when DRX is not used.

Updated

The counter is incremented by 1 when the closing of "DRX" and the


Frequency of source cell and target cell are not same.

9.11.3.8 C373485188 Successfu Outgoing Inter-frequency Handovers Non-DRX


Definition

The counter is used to count the number of successful outgoing inter-freq


handovers when DRX is not used.

Sampling Interval

Event triggered

Counter Type

Accumulative
9-288

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReconfigurationComplete message from UE in intra-eNB handover.
When the source eNodeB receives the UEContextRelease message from
the target eNodeB in inter-eNB X2 handover.
When the source eNodeB receives the UEContextReleaseCommand
message from the MME in inter-eNB S1 handover.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete sent


from the UE to the target eNB, indicating a successful outgoing intra-eNB
handover when DRX is not used when DRX is not used, or receipt at the
source eNB of UE CONTEXT RELEASE over the X2 from the target eNB
following a successful handover when DRX is not used, or if handover is
performed via S1, receipt of UE CONTEXT RELEASE COMMAND at the
source eNB following a successful handoverwhen DRX is not used.

Updated

The counter is incremented by 1 when the opening of "DRX" and the


Frequency of source cell and target cell are not same.

9.12 GAP Handover


9.12.1 Flow Charts and Sampling Points
Refer to:
l
l
l

Figure 8-1 Intra-eNB Handover


Figure 8-2 X2 Handover(1), Figure 8-3 X2 Handover(2)
Figure 8-4 S1 Handover(1), Figure 8-5 S1 Handover(2)

9.12.2 Counter List


NO.

Counter

Counter Name

Number
1

C373485189

Attempted Outgoing Inter-frequency Handovers Gap-assisted


Measurement

C373485190

Successful Outgoing Inter-frequency Handovers Gap-assisted


Measurement

C373485191

Attempted Outgoing Inter-frequency Handovers Non Gap-assisted


Measurement

C373485192

Successful Outgoing Inter-frequency Handovers Non Gap-assisted


Measurement

9-289
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

9.12.3 Counter Description


9.12.3.1 C373485189 Attempted Outgoing Inter-frequency Handovers Gap-assisted
Measurement
Definition

The counter is used to count the number of attempted outgoing inter-freq


handovers when measurement gaps are used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfigurationmessage to UE.

Explanation

Transmission of the RRCConnectionReconfiguration message by the


eNB to UE triggering the handover, indicating the attempt of an outgoing
inter-frequency handover when measurement gaps are used.

Updated

The counter is incremented by 1 when the opening of "GAP" and the


Frequency of source cell and target cell are not same.

9.12.3.2 C373485190 Successful Outgoing Inter-frequency Handovers Gap-assisted


Measurement
Definition

The counter is used to count the number of successful outgoing inter-freq


handovers when measurement gaps are used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB receives the RRCConnectionReconfigurationComplete message from UE in intra-eNB handover.
When the source eNodeB receives the UEContextRelease message from
the target eNodeB in inter-eNB X2 handover.
When the source eNodeB receives the UEContextReleaseCommand
message from the MME in inter-eNB S1 handover.

9-290
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 9 Statistics of Handover

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target eNB, indicating a successful outgoing
intra-eNB inter-frequency handover when measurement gaps are used, or
receipt at the source eNB of UE CONTEXT RELEASE over the X2 from
the target eNB or following a successful inter-frequency handover when
measurement gaps are used, or if handover is performed via S1, receipt
of UE CONTEXT RELEASE COMMAND at the source eNB following a
successful inter-frequency handover when measurement gaps are used.

Updated

The counter is incremented by 1 when the closing of "GAP" and the


Frequency of source cell and target cell are not same.

9.12.3.3 C373485191 Attempted Outgoing Inter-frequency Handovers Non


Gap-assisted Measurement
Definition

The counter is used to count the number of attempted outgoing inter-freq


handovers when measurement gaps are not used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the source eNodeB sends the RRCConnectionReconfigurationmessage to UE.

Explanation

Transmission of the RRCConnectionReconfiguration message by the


eNB to UE triggering the handover, indicating the attempt of an outgoing
inter-frequency handover when measurement gaps are not used.

Updated

The counter is incremented by 1 when the closing of "GAP" and the


Frequency of source cell and target cell are not same.

9.12.3.4 C373485192 Successful Outgoing Inter-frequency Handovers Non


Gap-assisted Measurement
Definition

The counter is used to count the number of successful outgoing inter-freq


handovers when measurement gaps are not used.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

9-291
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the source eNodeB receives the RRCConnectionReconfigurationComplete message from UE in intra-eNB handover.
When the source eNodeB receives the UEContextRelease message from
the target eNodeB in inter-eNB X2 handover.
When the source eNodeB receives the UEContextReleaseCommand
message from the MME in inter-eNB S1 handover.

Explanation

Receipt of a RRC message RRCConnectionReconfigurationComplete


sent from the UE to the target eNB, indicating a successful outgoing
intra-eNB inter-frequency handover when measurement gaps are not
used, or receipt at the source eNB of UE CONTEXT RELEASE over the
X2 from the target eNB following a successful inter-frequency handover
when measurement gaps are not used, or if handover is performed via
S1, receipt of UE CONTEXT RELEASE COMMAND at the source eNB
following a successful inter-frequency handover when measurement gaps
are not used.

Updated

The counter is incremented by 1 when the opening of "GAP" and the


Frequency of source cell and target cell are not same.

9-292
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10

Statistics of Traffic QoS


Table of Contents
Traffic Throughput on Cell ........................................................................................10-1
Traffic Delay on Cell .............................................................................................10-121
Loss Packet on Cell..............................................................................................10-133
User Number on Cell............................................................................................10-162
RLC PDU Number on Cell ....................................................................................10-186
Traffic Throughput on Cell(PLMN) ........................................................................10-187
Traffic Delay on Cell(PLMN) .................................................................................10-270
Loss Packet on Cell(PLMN)..................................................................................10-281
User Number on Cell(PLMN)................................................................................10-309

10.1 Traffic Throughput on Cell


10.1.1 PDCP SDU Bitrate
10.1.1.1 Flow Charts and Sampling Points
No chart.

10.1.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373374200

Average Bitrate of PDCP SDU in The UL in Control Plane

C373374201

Maximum Bitrate of PDCP SDU in The UL in Control Plane

C373374202

Average Bitrate of PDCP SDU in The DL in Control Plane

C373374203

Maximum Bitrate of PDCP SDU in The DL in Control Plane

C373374204

Average Bitrate of PDCP SDU in The UL (QCI=1)

C373374205

Average Bitrate of PDCP SDU in The UL (QCI=2)

C373374206

Average Bitrate of PDCP SDU in The UL (QCI=3)

C373374207

Average Bitrate of PDCP SDU in The UL (QCI=4)

C373374208

Average Bitrate of PDCP SDU in The UL (QCI=5)

10

C373374209

Average Bitrate of PDCP SDU in The UL (QCI=6)

10-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
11

C373374210

Average Bitrate of PDCP SDU in The UL (QCI=7)

12

C373374211

Average Bitrate of PDCP SDU in The UL (QCI=8)

13

C373374212

Average Bitrate of PDCP SDU in The UL (QCI=9)

14

C373374213

Average Bitrate of PDCP SDU in The DL (QCI=1)

15

C373374214

Average Bitrate of PDCP SDU in The DL (QCI=2)

16

C373374215

Average Bitrate of PDCP SDU in The DL (QCI=3)

17

C373374216

Average Bitrate of PDCP SDU in The DL (QCI=4)

18

C373374217

Average Bitrate of PDCP SDU in The DL (QCI=5)

19

C373374218

Average Bitrate of PDCP SDU in The DL (QCI=6)

20

C373374219

Average Bitrate of PDCP SDU in The DL (QCI=7)

21

C373374220

Average Bitrate of PDCP SDU in The DL (QCI=8)

22

C373374221

Average Bitrate of PDCP SDU in The DL (QCI=9)

23

C373374222

Maximum Bitrate of PDCP SDU in The UL (QCI=1)

24

C373374223

Maximum Bitrate of PDCP SDU in The UL (QCI=2)

25

C373374224

Maximum Bitrate of PDCP SDU in The UL (QCI=3)

26

C373374225

Maximum Bitrate of PDCP SDU in The UL (QCI=4)

27

C373374226

Maximum Bitrate of PDCP SDU in The UL (QCI=5)

28

C373374227

Maximum Bitrate of PDCP SDU in The UL (QCI=6)

29

C373374228

Maximum Bitrate of PDCP SDU in The UL (QCI=7)

30

C373374229

Maximum Bitrate of PDCP SDU in The UL (QCI=8)

31

C373374230

Maximum Bitrate of PDCP SDU in The UL (QCI=9)

32

C373374231

Maximum Bitrate of PDCP SDU in The DL (QCI=1)

33

C373374232

Maximum Bitrate of PDCP SDU in The DL (QCI=2)

34

C373374233

Maximum Bitrate of PDCP SDU in The DL (QCI=3)

35

C373374234

Maximum Bitrate of PDCP SDU in The DL (QCI=4)

36

C373374235

Maximum Bitrate of PDCP SDU in The DL (QCI=5)

37

C373374236

Maximum Bitrate of PDCP SDU in The DL (QCI=6)

38

C373374237

Maximum Bitrate of PDCP SDU in The DL (QCI=7)

39

C373374238

Maximum Bitrate of PDCP SDU in The DL (QCI=8)

40

C373374239

Maximum Bitrate of PDCP SDU in The DL (QCI=9)

41

C373374240

Maximum Bitrate of PDCP SDU in The UL in Traffic Plane

42

C373374241

Maximum Bitrate of PDCP SDU in The DL in Traffic Plane

10-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
43

C373374242

Average Bitrate of PDCP SDU in The UL in Traffic Plane

44

C373374243

Average Bitrate of PDCP SDU in The DL in Traffic Plane

10.1.1.3 Counter Description


10.1.1.3.1 C373374200 Average Bitrate of PDCP SDU in The UL in Control Plane
Definition

The counter is used to count the average cell bit-rate of control plane
PDCP SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB sends the PDCP SDU of signal radio bear to the MME.

Explanation

At sampling time,the eNodeB collects the UL PDCP SDU volume of SRB


that is sent by PDCP layer from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL SRB PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.2 C373374201 Maximum Bitrate of PDCP SDU in The UL in Control Plane


Definition

The counter is used to count the maximum cell bit-rate of control plane
PDCP SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB sends the PDCP SDU of signal radio bear to the MME.

Explanation

At sampling time,the eNodeB collects the UL PDCP SDU volume of


SRB that is sent by PDCP layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
SDU volume is larger than the prior at sampling point.

10-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.1.3.3 C373374202 Average Bitrate of PDCP SDU in The DL in Control Plane


Definition

The counter is used to count the average cell bit-rate of control plane
PDCP SDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the PDCP SDU of signal radio bear from the
MME.

Explanation

At sampling time,the eNodeB collects the DL PDCP SDU volume of SRB


that is received by PDCP layer from the previous sampling time to the
current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL SRB PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.4 C373374203 Maximum Bitrate of PDCP SDU in The DL in Control Plane


Definition

The counter is used to count the maximum cell bit-rate of control plane
PDCP SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the PDCP SDU of signal radio bear from the
MME.

Explanation

At sampling time,the eNodeB collects the DL PDCP SDU volume of SRB


that is received by PDCP layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL SRB
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.5 C373374204 Average Bitrate of PDCP SDU in The UL (QCI=1)


Definition

The counter is used to count the average cell bit-rate of QCI1 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

10-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI1 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.6 C373374205 Average Bitrate of PDCP SDU in The UL (QCI=2)


Definition

The counter is used to count the average cell bit-rate of QCI2 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI2 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.7 C373374206 Average Bitrate of PDCP SDU in The UL (QCI=3)


Definition

The counter is used to count the average cell bit-rate of QCI3 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 PDCP SDU to the SGW.

10-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI3 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.8 C373374207 Average Bitrate of PDCP SDU in The UL (QCI=4)


Definition

The counter is used to count the average cell bit-rate of QCI4 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI4 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.9 C373374208 Average Bitrate of PDCP SDU in The UL (QCI=5)


Definition

The counter is used to count the average cell bit-rate of QCI5 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

10-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is updated by accumulating all the sample UL QCI5 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.10 C373374209 Average Bitrate of PDCP SDU in The UL (QCI=6)


Definition

The counter is used to count the average cell bit-rate of QCI6 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI6 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.11 C373374210 Average Bitrate of PDCP SDU in The UL (QCI=7)


Definition

The counter is used to count the average cell bit-rate of QCI7 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI7 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.12 C373374211 Average Bitrate of PDCP SDU in The UL (QCI=8)


Definition

The counter is used to count the average cell bit-rate of QCI8 PDCP
SDUs on the uplink.
10-7

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI8 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.13 C373374212 Average Bitrate of PDCP SDU in The UL (QCI=9)


Definition

The counter is used to count the average cell bit-rate of QCI9 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI9 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.14 C373374213 Average Bitrate of PDCP SDU in The DL (QCI=1)


Definition

The counter is used to count the average cell bit-rate of QCI1 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

10-8
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB receives the QCI1 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI1 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.15 C373374214 Average Bitrate of PDCP SDU in The DL (QCI=2)


Definition

The counter is used to count the average cell bit-rate of QCI2 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI2 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI2 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.16 C373374215 Average Bitrate of PDCP SDU in The DL (QCI=3)


Definition

The counter is used to count the average cell bit-rate of QCI3 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI3 PDCP SDU from the SGW or the
other eNodeB.

10-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI3 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.17 C373374216 Average Bitrate of PDCP SDU in The DL (QCI=4)


Definition

The counter is used to count the average cell bit-rate of QCI4 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI4 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI4 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.18 C373374217 Average Bitrate of PDCP SDU in The DL (QCI=5)


Definition

The counter is used to count the average cell bit-rate of QCI5 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI5 PDCP SDU from the SGW or the
other eNodeB.

10-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI5 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.19 C373374218 Average Bitrate of PDCP SDU in The DL (QCI=6)


Definition

The counter is used to count the average cell bit-rate of QCI6 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI6 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI6 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.20 C373374219 Average Bitrate of PDCP SDU in The DL (QCI=7)


Definition

The counter is used to count the average cell bit-rate of QCI7 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI7 PDCP SDU from the SGW or the
other eNodeB.

10-11
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI7 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.21 C373374220 Average Bitrate of PDCP SDU in The DL (QCI=8)


Definition

The counter is used to count the average cell bit-rate of QCI8 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI8 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI8 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.22 C373374221 Average Bitrate of PDCP SDU in The DL (QCI=9)


Definition

The counter is used to count the average cell bit-rate of QCI9 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI9 PDCP SDU from the SGW or the
other eNodeB.

10-12
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI9 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.1.1.3.23 C373374222 Maximum Bitrate of PDCP SDU in The UL (QCI=1)


Definition

The counter is used to count the maximum cell bit-rate of QCI1 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted.The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.24 C373374223 Maximum Bitrate of PDCP SDU in The UL (QCI=2)


Definition

The counter is used to count the maximum cell bit-rate of QCI2 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

10-13
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI2
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.25 C373374224 Maximum Bitrate of PDCP SDU in The UL (QCI=3)


Definition

The counter is used to count the maximum cell bit-rate of QCI3 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.26 C373374225 Maximum Bitrate of PDCP SDU in The UL (QCI=4)


Definition

The counter is used to count the maximum cell bit-rate of QCI4 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.27 C373374226 Maximum Bitrate of PDCP SDU in The UL (QCI=5)


Definition

The counter is used to count the maximum cell bit-rate of QCI5 PDCP
SDUs on the uplink.
10-14

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.28 C373374227 Maximum Bitrate of PDCP SDU in The UL (QCI=6)


Definition

The counter is used to count the maximum cell bit-rate of QCI6 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.29 C373374228 Maximum Bitrate of PDCP SDU in The UL (QCI=7)


Definition

The counter is used to count the maximum cell bit-rate of QCI7 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 PDCP SDU to the SGW.

10-15
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.30 C373374229 Maximum Bitrate of PDCP SDU in The UL (QCI=8)


Definition

The counter is used to count the maximum cell bit-rate of QCI8 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.31 C373374230 Maximum Bitrate of PDCP SDU in The UL (QCI=9)


Definition

The counter is used to count the maximum cell bit-rate of QCI9 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

10-16
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI9
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.32 C373374231 Maximum Bitrate of PDCP SDU in The DL (QCI=1)


Definition

The counter is used to count the maximum cell bit-rate of QCI1 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI1 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.33 C373374232 Maximum Bitrate of PDCP SDU in The DL (QCI=2)


Definition

The counter is used to count the maximum cell bit-rate of QCI2 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI2 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
PDCP SDU volume is larger than the prior at sampling point.

10-17
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.1.3.34 C373374233 Maximum Bitrate of PDCP SDU in The DL (QCI=3)


Definition

The counter is used to count the maximum cell bit-rate of QCI3 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI3 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.35 C373374234 Maximum Bitrate of PDCP SDU in The DL (QCI=4)


Definition

The counter is used to count the maximum cell bit-rate of QCI4 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI4 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.36 C373374235 Maximum Bitrate of PDCP SDU in The DL (QCI=5)


Definition

The counter is used to count the maximum cell bit-rate of QCI5 PDCP
SDUs on the downlink.

Sampling Interval

1s
10-18

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI5 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.37 C373374236 Maximum Bitrate of PDCP SDU in The DL (QCI=6)


Definition

The counter is used to count the maximum cell bit-rate of QCI6 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI6 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.38 C373374237 Maximum Bitrate of PDCP SDU in The DL (QCI=7)


Definition

The counter is used to count the maximum cell bit-rate of QCI7 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

10-19
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the QCI7 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.39 C373374238 Maximum Bitrate of PDCP SDU in The DL (QCI=8)


Definition

The counter is used to count the maximum cell bit-rate of QCI8 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI8 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.40 C373374239 Maximum Bitrate of PDCP SDU in The DL (QCI=9)


Definition

The counter is used to count the maximum cell bit-rate of QCI9 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the QCI9 PDCP SDU from the SGW or the
other eNodeB.

10-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
PDCP SDU volume is larger than the prior at sampling point.

10.1.1.3.41 C373374240 Maximum Bitrate of PDCP SDU in The UL in Traffic Plane


Definition

The counter is used to count the maximum cell bit-rate of PDCP SDUs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is sent
by PDCP layer from the previous sampling time to the current sampling
time. PDCP SDUs that are forwarded over the X2/S1 to another eNodeB
during handover have been deducted. The counter provides the maximum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
SDU volume is larger than the prior at sampling point.

10.1.1.3.42 C373374241 Maximum Bitrate of PDCP SDU in The DL in Traffic Plane


Definition

The counter is used to count the maximum cell bit-rate of PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the PDCP SDU from the SGW or the other
eNodeB.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is


received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

10-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL PDCP
SDU volume is larger than the prior at sampling point.

10.1.1.3.43 C373374242 Average Bitrate of PDCP SDU in The UL in Traffic Plane


Definition

The counter is used to count the average cell bit-rate of PDCP SDUs on
the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is sent
by PDCP layer from the previous sampling time to the current sampling
time. PDCP SDUs that are forwarded over the X2/S1 to another eNodeB
during handover have been deducted. The counter provides the average
value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL PDCP SDU


volume, and then dividing the sum by the measurement period.

10.1.1.3.44 C373374243 Average Bitrate of PDCP SDU in The DL in Traffic Plane


Definition

The counter is used to count the average cell bit-rate of PDCP SDUs on
the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB receives the PDCP SDU from the SGW or the other
eNodeB.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is


received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL PDCP SDU


volume, and then dividing the sum by the measurement period.

10-22
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.2 PDCP PDU Throughput


10.1.2.1 Flow Charts and Sampling Points
Figure 10-1 PDCP PDU Throughput

10.1.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343600

Maximum Cell DL PDCP Throughput

C373343601

Minimum Cell DL PDCP Throughput

C373343602

Average Cell DL PDCP Throughput

C373343603

Maximum Cell UL PDCP Throughput

C373343604

Minimum Cell UL PDCP Throughput

C373343605

Average Cell UL PDCP Throughput

C373343606

Maximum Cell DL PDCP Throughput(QCI=1)

C373343607

Minimum Cell DL PDCP Throughput(QCI=1)

C373343608

Average Cell DL PDCP Throughput(QCI=1)

10

C373343609

Maximum Cell UL PDCP Throughput(QCI=1)

11

C373343610

Minimum Cell UL PDCP Throughput(QCI=1)

12

C373343611

Average Cell UL PDCP Throughput(QCI=1)

10-23
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
13

C373343612

Maximum Cell DL PDCP Throughput(QCI=2)

14

C373343613

Minimum Cell DL PDCP Throughput(QCI=2)

15

C373343614

Average Cell DL PDCP Throughput(QCI=2)

16

C373343615

Maximum Cell UL PDCP Throughput(QCI=2)

17

C373343616

Minimum Cell UL PDCP Throughput(QCI=2)

18

C373343617

Average Cell UL PDCP Throughput(QCI=2)

19

C373343618

Maximum Cell DL PDCP Throughput(QCI=3)

20

C373343619

Minimum Cell DL PDCP Throughput(QCI=3)

21

C373343620

Average Cell DL PDCP Throughput(QCI=3)

22

C373343621

Maximum Cell UL PDCP Throughput(QCI=3)

23

C373343622

Minimum Cell UL PDCP Throughput(QCI=3)

24

C373343623

Average Cell UL PDCP Throughput(QCI=3)

25

C373343624

Maximum Cell DL PDCP Throughput(QCI=4)

26

C373343625

Minimum Cell DL PDCP Throughput(QCI=4)

27

C373343626

Average Cell DL PDCP Throughput(QCI=4)

28

C373343627

Maximum Cell UL PDCP Throughput(QCI=4)

29

C373343628

Minimum Cell UL PDCP Throughput(QCI=4)

30

C373343629

Average Cell UL PDCP Throughput(QCI=4)

31

C373343630

Maximum Cell DL PDCP Throughput(QCI=5)

32

C373343631

Minimum Cell DL PDCP Throughput(QCI=5)

33

C373343632

Average Cell DL PDCP Throughput(QCI=5)

34

C373343633

Maximum Cell UL PDCP Throughput(QCI=5)

35

C373343634

Minimum Cell UL PDCP Throughput(QCI=5)

36

C373343635

Average Cell UL PDCP Throughput(QCI=5)

37

C373343636

Maximum Cell DL PDCP Throughput(QCI=6)

38

C373343637

Minimum Cell DL PDCP Throughput(QCI=6)

39

C373343638

Average Cell DL PDCP Throughput(QCI=6)

40

C373343639

Maximum Cell UL PDCP Throughput(QCI=6)

41

C373343640

Minimum Cell UL PDCP Throughput(QCI=6)

42

C373343641

Average Cell UL PDCP Throughput(QCI=6)

43

C373343642

Maximum Cell DL PDCP Throughput(QCI=7)

44

C373343643

Minimum Cell DL PDCP Throughput(QCI=7)

10-24
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
45

C373343644

Average Cell DL PDCP Throughput(QCI=7)

46

C373343645

Maximum Cell UL PDCP Throughput(QCI=7)

47

C373343646

Minimum Cell UL PDCP Throughput(QCI=7)

48

C373343647

Average Cell UL PDCP Throughput(QCI=7)

49

C373343648

Maximum Cell DL PDCP Throughput(QCI=8)

50

C373343649

Minimum Cell DL PDCP Throughput(QCI=8)

51

C373343650

Average Cell DL PDCP Throughput(QCI=8)

52

C373343651

Maximum Cell UL PDCP Throughput(QCI=8)

53

C373343652

Minimum Cell UL PDCP Throughput(QCI=8)

54

C373343653

Average Cell UL PDCP Throughput(QCI=8)

55

C373343654

Maximum Cell DL PDCP Throughput(QCI=9)

56

C373343655

Minimum Cell DL PDCP Throughput(QCI=9)

57

C373343656

Average Cell DL PDCP Throughput(QCI=9)

58

C373343657

Maximum Cell UL PDCP Throughput(QCI=9)

59

C373343658

Minimum Cell UL PDCP Throughput(QCI=9)

60

C373343659

Average Cell UL PDCP Throughput(QCI=9)

10.1.2.3 Counter Description


10.1.2.3.1 C373343600 Maximum Cell DL PDCP Throughput
Definition

The counter is used to count the maximum cell throughput of PDCP PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the PDU to the eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is sent by PDCP layer to RLC layer from the
previous sampling time to the current sampling time. The counter provides
the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL PDCP
PDU volume is larger than the prior at sampling point.
10-25

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.2.3.2 C373343601 Minimum Cell DL PDCP Throughput


Definition

The counter is used to count the minimum cell throughput of PDCP PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the PDU to the eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is sent by PDCP layer to RLC layer from the
previous sampling time to the current sampling time. The counter provides
the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL PDCP
PDU volume is smaller than the prior at sampling point.

10.1.2.3.3 C373343602 Average Cell DL PDCP Throughput


Definition

The counter is used to count the average cell throughput of PDCP PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the PDU to the eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is sent by PDCP layer to RLC layer from the
previous sampling time to the current sampling time. The counter provides
the average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL PDCP PDU


volume, and then dividing the sum by the measurement period.

10.1.2.3.4 C373343603 Maximum Cell UL PDCP Throughput


Definition

The counter is used to count the maximum cell throughput of PDCP PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell
10-26

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer receives the PDU from the eNodeB RLC
layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that
includes the DRB's and SRB's and is received by PDCP layer from RLC
layer from the previous sampling time to the current sampling time. The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
PDU volume is larger than the prior at sampling point.

10.1.2.3.5 C373343604 Minimum Cell UL PDCP Throughput


Definition

The counter is used to count the minimum cell throughput of PDCP PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the PDU from the eNodeB RLC
layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that
includes the DRB's and SRB's and is received by PDCP layer from RLC
layer from the previous sampling time to the current sampling time. The
counter provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
PDU volume is smaller than the prior at sampling point.

10.1.2.3.6 C373343605 Average Cell UL PDCP Throughput


Definition

The counter is used to count the average cell throughput of PDCP PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the PDU from the eNodeB RLC
layer.

10-27
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is received by PDCP layer from RLC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL PDCP PDU


volume, and then dividing the sum by the measurement period.

10.1.2.3.7 C373343606 Maximum Cell DL PDCP Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.8 C373343607 Minimum Cell DL PDCP Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

10-28
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI1
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.9 C373343608 Average Cell DL PDCP Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI1 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.10 C373343609 Maximum Cell UL PDCP Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.11 C373343610 Minimum Cell UL PDCP Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 PDCP
PDUs on the uplink.
10-29

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.12 C373343611 Average Cell UL PDCP Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI1 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.13 C373343612 Maximum Cell DL PDCP Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

10-30
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer sends the QCI2 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.14 C373343613 Minimum Cell DL PDCP Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.15 C373343614 Average Cell DL PDCP Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

10-31
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample DL QCI2 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.16 C373343615 Maximum Cell UL PDCP Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.17 C373343616 Minimum Cell UL PDCP Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.18 C373343617 Average Cell UL PDCP Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 PDCP
PDUs on the uplink.
10-32

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI2 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.19 C373343618 Maximum Cell DL PDCP Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.20 C373343619 Minimum Cell DL PDCP Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

10-33
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer sends the QCI3 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.21 C373343620 Average Cell DL PDCP Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI3 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.22 C373343621 Maximum Cell UL PDCP Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

10-34
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI3
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.23 C373343622 Minimum Cell UL PDCP Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.24 C373343623 Average Cell UL PDCP Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI3 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.25 C373343624 Maximum Cell DL PDCP Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 PDCP
PDUs on the downlink.
10-35

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.26 C373343625 Minimum Cell DL PDCP Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.27 C373343626 Average Cell DL PDCP Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

10-36
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer sends the QCI4 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI4 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.28 C373343627 Maximum Cell UL PDCP Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.29 C373343628 Minimum Cell UL PDCP Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

10-37
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI4
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.30 C373343629 Average Cell UL PDCP Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI4 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.31 C373343630 Maximum Cell DL PDCP Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.32 C373343631 Minimum Cell DL PDCP Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 PDCP
PDUs on the downlink.
10-38

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.33 C373343632 Average Cell DL PDCP Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI5 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.34 C373343633 Maximum Cell UL PDCP Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

10-39
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer receives the QCI5 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.35 C373343634 Minimum Cell UL PDCP Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.36 C373343635 Average Cell UL PDCP Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

10-40
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is updated by accumulating all the sample UL QCI5 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.37 C373343636 Maximum Cell DL PDCP Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.38 C373343637 Minimum Cell DL PDCP Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.39 C373343638 Average Cell DL PDCP Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 PDCP
PDUs on the downlink.
10-41

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI6 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.40 C373343639 Maximum Cell UL PDCP Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.41 C373343640 Minimum Cell UL PDCP Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

10-42
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer receives the QCI6 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.42 C373343641 Average Cell UL PDCP Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI6 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.43 C373343642 Maximum Cell DL PDCP Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

10-43
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI7
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.44 C373343643 Minimum Cell DL PDCP Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.45 C373343644 Average Cell DL PDCP Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI7 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.46 C373343645 Maximum Cell UL PDCP Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 PDCP
PDUs on the uplink.
10-44

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI7 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.47 C373343646 Minimum Cell UL PDCP Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI7 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.48 C373343647 Average Cell UL PDCP Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

10-45
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer receives the QCI7 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI7 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.49 C373343648 Maximum Cell DL PDCP Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.50 C373343649 Minimum Cell DL PDCP Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

10-46
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI8
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.51 C373343650 Average Cell DL PDCP Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI8 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.52 C373343651 Maximum Cell UL PDCP Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.53 C373343652 Minimum Cell UL PDCP Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 PDCP
PDUs on the uplink.
10-47

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.54 C373343653 Average Cell UL PDCP Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI8 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.55 C373343654 Maximum Cell DL PDCP Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

10-48
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer sends the QCI9 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.56 C373343655 Minimum Cell DL PDCP Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.57 C373343656 Average Cell DL PDCP Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

10-49
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample DL QCI9 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.2.3.58 C373343657 Maximum Cell UL PDCP Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
PDCP PDU volume is larger than the prior at sampling point.

10.1.2.3.59 C373343658 Minimum Cell UL PDCP Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
PDCP PDU volume is smaller than the prior at sampling point.

10.1.2.3.60 C373343659 Average Cell UL PDCP Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 PDCP
PDUs on the uplink.
10-50

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI9 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.1.3 RLC PDU Throughput


10.1.3.1 Flow Charts and Sampling Points
Figure 10-2 RLC PDU Throughput

10-51
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343660

Maximum Cell DL RLC Throughput

C373343661

Minimum Cell DL RLC Throughput

C373343662

Average Cell DL RLC Throughput

C373343663

Maximum Cell UL RLC Throughput

C373343664

Minimum Cell UL RLC Throughput

C373343665

Average Cell UL RLC Throughput

C373343666

Maximum Cell DL RLC Throughput(QCI=1)

C373343667

Minimum Cell DL RLC Throughput(QCI=1)

C373343668

Average Cell DL RLC Throughput(QCI=1)

10

C373343669

Maximum Cell UL RLC Throughput(QCI=1)

11

C373343670

Minimum Cell UL RLC Throughput(QCI=1)

12

C373343671

Average Cell UL RLC Throughput(QCI=1)

13

C373343672

Maximum Cell DL RLC Throughput(QCI=2)

14

C373343673

Minimum Cell DL RLC Throughput(QCI=2)

15

C373343674

Average Cell DL RLC Throughput(QCI=2)

16

C373343675

Maximum Cell UL RLC Throughput(QCI=2)

17

C373343676

Minimum Cell UL RLC Throughput(QCI=2)

18

C373343677

Average Cell UL RLC Throughput(QCI=2)

19

C373343678

Maximum Cell DL RLC Throughput(QCI=3)

20

C373343679

Minimum Cell DL RLC Throughput(QCI=3)

21

C373343680

Average Cell DL RLC Throughput(QCI=3)

22

C373343681

Maximum Cell UL RLC Throughput(QCI=3)

23

C373343682

Minimum Cell UL RLC Throughput(QCI=3)

24

C373343683

Average Cell UL RLC Throughput(QCI=3)

25

C373343684

Maximum Cell DL RLC Throughput(QCI=4)

26

C373343685

Minimum Cell DL RLC Throughput(QCI=4)

27

C373343686

Average Cell DL RLC Throughput(QCI=4)

28

C373343687

Maximum Cell UL RLC Throughput(QCI=4)

29

C373343688

Minimum Cell UL RLC Throughput(QCI=4)

30

C373343689

Average Cell UL RLC Throughput(QCI=4)

31

C373343690

Maximum Cell DL RLC Throughput(QCI=5)


10-52

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
32

C373343691

Minimum Cell DL RLC Throughput(QCI=5)

33

C373343692

Average Cell DL RLC Throughput(QCI=5)

34

C373343693

Maximum Cell UL RLC Throughput(QCI=5)

35

C373343694

Minimum Cell UL RLC Throughput(QCI=5)

36

C373343695

Average Cell UL RLC Throughput(QCI=5)

37

C373343696

Maximum Cell DL RLC Throughput(QCI=6)

38

C373343697

Minimum Cell DL RLC Throughput(QCI=6)

39

C373343698

Average Cell DL RLC Throughput(QCI=6)

40

C373343699

Maximum Cell UL RLC Throughput(QCI=6)

41

C373343700

Minimum Cell UL RLC Throughput(QCI=6)

42

C373343701

Average Cell UL RLC Throughput(QCI=6)

43

C373343702

Maximum Cell DL RLC Throughput(QCI=7)

44

C373343703

Minimum Cell DL RLC Throughput(QCI=7)

45

C373343704

Average Cell DL RLC Throughput(QCI=7)

46

C373343705

Maximum Cell UL RLC Throughput(QCI=7)

47

C373343706

Minimum Cell UL RLC Throughput(QCI=7)

48

C373343707

Average Cell UL RLC Throughput(QCI=7)

49

C373343708

Maximum Cell DL RLC Throughput(QCI=8)

50

C373343709

Minimum Cell DL RLC Throughput(QCI=8)

51

C373343710

Average Cell DL RLC Throughput(QCI=8)

52

C373343711

Maximum Cell UL RLC Throughput(QCI=8)

53

C373343712

Minimum Cell UL RLC Throughput(QCI=8)

54

C373343713

Average Cell UL RLC Throughput(QCI=8)

55

C373343714

Maximum Cell DL RLC Throughput(QCI=9)

56

C373343715

Minimum Cell DL RLC Throughput(QCI=9)

57

C373343716

Average Cell DL RLC Throughput(QCI=9)

58

C373343717

Maximum Cell UL RLC Throughput(QCI=9)

59

C373343718

Minimum Cell UL RLC Throughput(QCI=9)

60

C373343719

Average Cell UL RLC Throughput(QCI=9)

10-53
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3 Counter Description


10.1.3.3.1 C373343660 Maximum Cell DL RLC Throughput
Definition

The counter is used to count the maximum cell throughput of RLC PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the PDU to the eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is sent by RLC layer to MAC layer from the
previous sampling time to the current sampling time.The volume includes
retransmission's PDU. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL RLC
PDU volume is larger than the prior at sampling point.

10.1.3.3.2 C373343661 Minimum Cell DL RLC Throughput


Definition

The counter is used to count the minimum cell throughput of RLC PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the PDU to the eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is sent by RLC layer to MAC layer from the
previous sampling time to the current sampling time.The volume includes
retransmission's PDU.The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL RLC
PDU volume is smaller than the prior at sampling point.

10.1.3.3.3 C373343662 Average Cell DL RLC Throughput


Definition

The counter is used to count the average cell throughput of RLC PDUs
on the downlink.

Sampling Interval

1s
10-54

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the PDU to the eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is sent by RLC layer to MAC layer from the
previous sampling time to the current sampling time.The volume includes
retransmission's PDU. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL RLC PDU


volume, and then dividing the sum by the measurement period.

10.1.3.3.4 C373343663 Maximum Cell UL RLC Throughput


Definition

The counter is used to count the maximum cell throughput of RLC PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the PDU from the eNodeB MAC
layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is received by RLC layer from MAC layer from the
previous sampling time to the current sampling time. The volume includes
retransmission's PDU. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL RLC
PDU volume is larger than the prior at sampling point.

10.1.3.3.5 C373343664 Minimum Cell UL RLC Throughput


Definition

The counter is used to count the minimum cell throughput of RLC PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the PDU from the eNodeB MAC
layer.
10-55

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is received by RLC layer from MAC layer from the
previous sampling time to the current sampling time. The volume includes
retransmission's PDU. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL RLC
PDU volume is smaller than the prior at sampling point.

10.1.3.3.6 C373343665 Average Cell UL RLC Throughput


Definition

The counter is used to count the average cell throughput of RLC PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the PDU from the eNodeB MAC
layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is received by RLC layer from MAC layer from
the previous sampling time to the current sampling time. The volume
includes retransmission's PDU. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL RLC PDU


volume, and then dividing the sum by the measurement period.

10.1.3.3.7 C373343666 Maximum Cell DL RLC Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI1 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that is
sent by RLC layer to MAC layer from the previous sampling time to the
current sampling time.The volume includes retransmission's PDU. The
counter provides the maximum value in the measurement period.

10-56
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI1
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.8 C373343667 Minimum Cell DL RLC Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI1 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.9 C373343668 Average Cell DL RLC Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI1 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI1 RLC PDU
volume, and then dividing the sum by the measurement period.

10-57
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3.10 C373343669 Maximum Cell UL RLC Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI1 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.11 C373343670 Minimum Cell UL RLC Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI1 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.12 C373343671 Average Cell UL RLC Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

10-58
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI1 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI1 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.13 C373343672 Maximum Cell DL RLC Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI2 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.14 C373343673 Minimum Cell DL RLC Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI2 DRB PDU to the eNodeB
MAC layer.

10-59
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.15 C373343674 Average Cell DL RLC Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI2 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI2 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.16 C373343675 Maximum Cell UL RLC Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI2 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

10-60
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI2
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.17 C373343676 Minimum Cell UL RLC Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI2 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.18 C373343677 Average Cell UL RLC Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI2 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI2 RLC PDU
volume, and then dividing the sum by the measurement period.

10-61
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3.19 C373343678 Maximum Cell DL RLC Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI3 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.20 C373343679 Minimum Cell DL RLC Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI3 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.21 C373343680 Average Cell DL RLC Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

10-62
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI3 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI3 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.22 C373343681 Maximum Cell UL RLC Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI3 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.23 C373343682 Minimum Cell UL RLC Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI3 DRB PDU from the
eNodeB MAC layer.

10-63
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.24 C373343683 Average Cell UL RLC Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI3 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI3 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.25 C373343684 Maximum Cell DL RLC Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI4 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

10-64
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI4
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.26 C373343685 Minimum Cell DL RLC Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI4 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.27 C373343686 Average Cell DL RLC Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI4 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI4 RLC PDU
volume, and then dividing the sum by the measurement period.

10-65
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3.28 C373343687 Maximum Cell UL RLC Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI4 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.29 C373343688 Minimum Cell UL RLC Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI4 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.30 C373343689 Average Cell UL RLC Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

10-66
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI4 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI4 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.31 C373343690 Maximum Cell DL RLC Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI5 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.32 C373343691 Minimum Cell DL RLC Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI5 DRB PDU to the eNodeB
MAC layer.

10-67
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.33 C373343692 Average Cell DL RLC Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI5 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI5 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.34 C373343693 Maximum Cell UL RLC Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI5 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

10-68
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI5
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.35 C373343694 Minimum Cell UL RLC Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI5 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.36 C373343695 Average Cell UL RLC Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI5 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI5 RLC PDU
volume, and then dividing the sum by the measurement period.

10-69
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3.37 C373343696 Maximum Cell DL RLC Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI6 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.38 C373343697 Minimum Cell DL RLC Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI6 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.39 C373343698 Average Cell DL RLC Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

10-70
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI6 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI6 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.40 C373343699 Maximum Cell UL RLC Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI6 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.41 C373343700 Minimum Cell UL RLC Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI6 DRB PDU from the
eNodeB MAC layer.

10-71
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.42 C373343701 Average Cell UL RLC Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI6 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI6 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.43 C373343702 Maximum Cell DL RLC Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI7 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

10-72
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI7
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.44 C373343703 Minimum Cell DL RLC Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI7 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.45 C373343704 Average Cell DL RLC Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI7 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI7 RLC PDU
volume, and then dividing the sum by the measurement period.

10-73
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3.46 C373343705 Maximum Cell UL RLC Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI7 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.47 C373343706 Minimum Cell UL RLC Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI7 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.48 C373343707 Average Cell UL RLC Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

10-74
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI7 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI7 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.49 C373343708 Maximum Cell DL RLC Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI8 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.50 C373343709 Minimum Cell DL RLC Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI8 DRB PDU to the eNodeB
MAC layer.

10-75
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.51 C373343710 Average Cell DL RLC Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI8 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI8 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.52 C373343711 Maximum Cell UL RLC Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI8 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

10-76
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI8
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.53 C373343712 Minimum Cell UL RLC Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI8 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.54 C373343713 Average Cell UL RLC Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI8 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI8 RLC PDU
volume, and then dividing the sum by the measurement period.

10-77
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.3.3.55 C373343714 Maximum Cell DL RLC Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI9 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.56 C373343715 Minimum Cell DL RLC Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI9 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.57 C373343716 Average Cell DL RLC Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

10-78
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer sends the QCI9 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time.The volume
includes retransmission's PDU. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI9 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.3.3.58 C373343717 Maximum Cell UL RLC Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI9 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
RLC PDU volume is larger than the prior at sampling point.

10.1.3.3.59 C373343718 Minimum Cell UL RLC Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI9 DRB PDU from the
eNodeB MAC layer.

10-79
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
RLC PDU volume is smaller than the prior at sampling point.

10.1.3.3.60 C373343719 Average Cell UL RLC Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB RLC layer receives the QCI9 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI9 RLC PDU
volume, and then dividing the sum by the measurement period.

10.1.4 MAC TB Throughput


10.1.4.1 Flow Charts and Sampling Points

10-80
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Figure 10-3 MAC TB Throughput

10.1.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343720

Maximum Cell DL MAC Throughput

C373343721

Minimum Cell DL MAC Throughput

C373343722

Average Cell DL MAC Throughput

C373343723

Maximum Cell UL MAC Throughput

C373343724

Minimum Cell UL MAC Throughput

C373343725

Average Cell UL MAC Throughput

10.1.4.3 Counter Description


10.1.4.3.1 C373343720 Maximum Cell DL MAC Throughput
Definition

The counter is used to count the maximum cell throughput of MAC TBs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell
10-81

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB MAC layer sends the transport block to the eNodeB
PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is sent by MAC layer to PHY layer from the previous
sampling time to the current sampling time. The counter provides the
minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL MAC
TB volume is larger than the prior at sampling point.

10.1.4.3.2 C373343721 Minimum Cell DL MAC Throughput


Definition

The counter is used to count the minimum cell throughput of MAC TBs
on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB MAC layer sends the transport block to the eNodeB
PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is sent by MAC layer to PHY layer from the previous
sampling time to the current sampling time. The counter provides the
average value in the measurement period.

Updated

The counter is replaced with the current value when the current DL MAC
TB volume is smaller than the prior at sampling point.

10.1.4.3.3 C373343722 Average Cell DL MAC Throughput


Definition

The counter is used to count the average cell throughput of MAC TBs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB MAC layer sends the transport block to the eNodeB
PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is sent by MAC layer to PHY layer from the previous
sampling time to the current sampling time. The counter provides the
maximum value in the measurement period.

10-82
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is updated by accumulating all the sample DL MAC TB


volume, and then dividing the sum by the measurement period.

10.1.4.3.4 C373343723 Maximum Cell UL MAC Throughput


Definition

The counter is used to count the maximum cell throughput of MAC TBs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB MAC layer receives the transport block from the
eNodeB PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is received by MAC layer from PHY layer from the
previous sampling time to the current sampling time. The counter provides
the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL MAC
TB volume is larger than the prior at sampling point.

10.1.4.3.5 C373343724 Minimum Cell UL MAC Throughput


Definition

The counter is used to count the minimum cell throughput of MAC TBs
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB MAC layer receives the transport block from the
eNodeB PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is received by MAC layer from PHY layer from the
previous sampling time to the current sampling time. The counter provides
the average value in the measurement period.

Updated

The counter is replaced with the current value when the current UL MAC
TB volume is smaller than the prior at sampling point.

10.1.4.3.6 C373343725 Average Cell UL MAC Throughput


Definition

The counter is used to count the average cell throughput of MAC TBs
on the uplink.
10-83

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Cell

Sampling Point

When the eNodeB MAC layer receives the transport block from the
eNodeB PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is received by MAC layer from PHY layer from the
previous sampling time to the current sampling time. The counter provides
the maximum value in the measurement period.

Updated

The counter is updated by accumulating all the sample UL MAC TB


volume, and then dividing the sum by the measurement period.

10.1.5 PHY Throughput


10.1.5.1 Flow Charts and Sampling Points
No chart.

10.1.5.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343732

Maximum Cell DL PHY Throughput

C373343733

Minimum Cell DL PHY Throughput

C373343734

Average Cell DL PHY Throughput

C373343735

Maximum Cell UL PHY Throughput

C373343736

Minimum Cell UL PHY Throughput

C373343737

Average Cell UL PHY Throughput

C373343792

Maximum Cell DL PHY Throughput within The Threshold

C373343793

Average Cell DL PHY Throughput within The Threshold

C373343794

Maximum Cell UL PHY Throughput within The Threshold

10

C373343795

Average Cell UL PHY Throughput within The Threshold

10-84
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.5.3 Counter Description


10.1.5.3.1 C373343732 Maximum Cell DL PHY Throughput
Definition

The counter is used to count the maximum cell throughput of PHY data
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer sends data to the air.

Explanation

Downlink PHY Traffic on the Sampling Point = the size of TBs. The counter
takes the maximum value of all sampling granularities in the statistical
period.

Updated

The counter is updated to the sampling value if it is higher than the current
one.

10.1.5.3.2 C373343733 Minimum Cell DL PHY Throughput


Definition

The counter is used to count the minimum cell throughput of PHY data
on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer sends data to the air.

Explanation

Downlink PHY Traffic on the Sampling Point = the size of TBs. That
includes retransmission TBs. The counter takes the minimum value of all
sampling granularities in the statistical period.

Updated

The counter is updated to the sampling value if it is lower than the current
one.

10.1.5.3.3 C373343734 Average Cell DL PHY Throughput


Definition

The counter is used to count the average cell throughput of PHY data
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell
10-85

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB physical layer sends data to the air.

Explanation

Downlink PHY Traffic on the Sampling Point = the size of TBs.That


includes retransmission TBs.The counter takes the average value of all
sampling granularities in the statistical period.

Updated

The counter is updated by accumulating all the sampling physical layer


volume, and then dividing the sum by the measurement period.

10.1.5.3.4 C373343735 Maximum Cell UL PHY Throughput


Definition

The counter is used to count the maximum cell throughput of PHY data
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer receives data from the air.

Explanation

Uplink PHY Traffic on the Sampling Point = the size of TBs.That includes
retransmission TBs.The counter takes the maximum value of all sampling
granularities in the statistical period.

Updated

The counter is updated to the sampling value if it is larger than the current
one.

10.1.5.3.5 C373343736 Minimum Cell UL PHY Throughput


Definition

The counter is used to count the minimum cell throughput of PHY data
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer receives data from the air.

Explanation

Uplink PHY Traffic on the Sampling Point = the size of TBs. That includes
retransmission TBs.The counter takes the minimum value of all sampling
granularities in the statistical period.

Updated

The counter is updated to the sampling value if it is lower than the current
one.

10.1.5.3.6 C373343737 Average Cell UL PHY Throughput


Definition

The counter is used to count the average cell throughput of PHY data
on the uplink.
10-86

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer receives data from the air.

Explanation

Uplink PHY traffic on the sampling point = the size of TBs. That includes
retransmission TBs.The counter takes the average value of all sampling
granularities in the statistical period.

Updated

The counter is updated by accumulating all the sampling physical layer


volume, and then dividing the sum by the measurement period.

10.1.5.3.7 C373343792 Maximum Cell DL PHY Throughput within The Threshold


Definition

The counter is used to count the maximum DL PHY throughput within


the threshold.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When there are downlink data to be sent on the PHY,and the threshold
requirements for RSRP and SINR must be satisfied.These threshold
values can be set in OMC windows, and the default threshold requirements
are: RSRP > Threshold for RSRP Statistics and SINR > Threshold for
DL SINR Statistics.

Explanation

Downlink PHY Traffic on the Sampling Point = the size of TBs. when
threshold for RSRP and SINR Statistics is satisfied. The counter takes the
maximum value of all sampling granularities in the statistical period.

Updated

The counter is updated to the sampling value if it is larger than the current
one.

10.1.5.3.8 C373343793 Average Cell DL PHY Throughput within The Threshold


Definition

The counter is used to count the average DL PHY throughput within the
threshold.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

10-87
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When there are downlink data to be sent on the PHY channelfrom the
MAC layer, and the threshold requirements for RSRP and DL SINR must
be satisfied.

Explanation

The average cell DL physical throughput is calculated by summing up


transport block size in sampling period, and the transport block is within
threshold, but exclude retransmission transport block.Users can set these
threshold values, and the default threshold requirements are: RSRP >
Threshold for RSRP Statistics and DL SINR > Threshold for DL SINR
Statistics.The RSRP threshold is converted by Power Headroom reporting
that UE reports by means of period or event trigger.The DL SINR threshold
is converted by CQI reported by UE.

Updated

The counter is updated per statistical period by calculating the average.

10.1.5.3.9 C373343794 Maximum Cell UL PHY Throughput within The Threshold


Definition

The counter is used to count the maximum UL PHY throughput within


the threshold.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the uplink PHY receives the data, and the threshold requirements
for RSRP and SINR must be satisfied. Users can set these threshold
values, and the default threshold requirements are: RSRP > Threshold for
RSRP Statistics and SINR > Threshold for DL SINR Statistics.

Explanation

Uplink PHY Traffic on the Sampling Point = the size of TBs.when threshold
for RSRP and SINR Statistics is satisfied. The counter takes the maximum
value of all sampling granularities in the statistical period.

Updated

The counter is updated to the sampling value if it is larger than the current
one.

10.1.5.3.10 C373343795 Average Cell UL PHY Throughput within The Threshold


Definition

The counter is used to count the average UL PHY throughput within the
threshold.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the uplink PHY receives the data, and the threshold requirements
for RSRP and DL SINR must be satisfied.
10-88

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

The average cell DL physical throughput is calculated by summing up


transport block size in sampling period, and the transport block is within
threshold, but exclude retransmission transport block. Users can set these
threshold values, and the default threshold requirements are: RSRP >
Threshold for RSRP Statistics and DL SINR > Threshold for DL SINR
Statistics. The RSRP threshold is converted by Power Headroom reporting
that UE reports by means of period or event trigger.The DL SINR threshold
is converted by CQI reported by UE.

Updated

The counter is updated per statistical period by calculating the average.

10.1.6 MAC Aggregated Throughput


10.1.6.1 Flow Charts and Sampling Points
No chart.

10.1.6.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343726

Cell DL Aggregated Volume High

C373343727

Cell DL Aggregated Volume Low

C373343728

Cell UL Aggregated Volume High

C373343729

Cell UL Aggregated Volume Low

C373343730

Cell DL Aggregated Time

C373343731

Cell UL Aggregated Time

C373343800

Nack Data Volume High Bit of UL TB Block

C373343801

Nack Data Volume Low Bit of UL TB Block

C373343802

Nack Data Volume High Bit of DL TB Block

10

C373343803

Nack Data Volume Low Bit of DL TB Block

10.1.6.3 Counter Description


10.1.6.3.1 C373343726 Cell DL Aggregated Volume High
Definition

The counter is used to count the cell bit-size of MAC TBs on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative
10-89

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB downlink scheduler get positively acknowledged for the
transmitted transport block over the air.

Explanation

The counter provides the part of TBs transmitted by eNodeB to UE


on the downlink.The total TBs = Cell DL Aggregated Volume High +
Cell DL Aggregated Volume Low.When the eNodeB get the successful
DL TB HARQ feedback,the counter is collected. That is excluded the
retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB downlink


scheduler get positively acknowledged for the transmitted transport block
over the air.

10.1.6.3.2 C373343727 Cell DL Aggregated Volume Low


Definition

The counter is used to count the cell part bit-size of MAC TBs on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB downlink scheduler get positively acknowledged for the
transmitted transport block over the air.

Explanation

The counter provides the other part of TBs transmitted by eNodeB to


UE on the downlink.The total TBs = Cell DL Aggregated Volume High +
Cell DL Aggregated Volume Low.When the eNodeB get the successful
DL TB HARQ feedback,the counter is collected. That is excluded the
retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB downlink


scheduler get positively acknowledged for the transmitted transport block
over the air.

10.1.6.3.3 C373343728 Cell UL Aggregated Volume High


Definition

The counter is used to count the cell part bit-size of MAC TBs on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

10-90
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB uplink scheduler get positively acknowledged for the
transmitted transport block by UE.

Explanation

The counter provides the part of TBs transmitted by UE to eNodeB


on the uplink.The total TBs = Cell UL Aggregated Volume High + Cell
UL Aggregated Volume Low.When the eNodeB get the successful UL
TB HARQ feedback,the counter is collected. That is excluded the
retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB uplink


scheduler get positively acknowledged for the transmitted transport block
by UE.

10.1.6.3.4 C373343729 Cell UL Aggregated Volume Low


Definition

The counter is used to count the cell part bit-size of MAC TBs on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB uplink scheduler get positively acknowledged for the
transmitted transport block by UE.

Explanation

The counter provides the other part of TBs transmitted by UE to eNodeB


on the uplink.The total TBs = Cell UL Aggregated Volume High + Cell
UL Aggregated Volume Low.When the eNodeB get the successful UL
TB HARQ feedback,the counter is collected. That is excluded the
retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB uplink


scheduler get positively acknowledged for the transmitted transport block
by UE.

10.1.6.3.5 C373343730 Cell DL Aggregated Time


Definition

The counter is used to count the sum of TTI to transmit TBs on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When the eNodeB downlink scheduler schedule the transport block.

10-91
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the DL TTI which has data scheduling.When the
eNodeB downlink scheduler schedule the transport block, one TTI is added
to the counter including the TTI of retransmission TB.

Updated

The counter is increased by 1 when the eNodeB downlink scheduler


schedule the transport block.

10.1.6.3.6 C373343731 Cell UL Aggregated Time


Definition

The counter is used to count the sum of TTI to transmit TBs on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When the eNodeB uplink scheduler schedule the transport block.

Explanation

The counter provides the UL TTI which has data scheduling.When the
eNodeB uplink scheduler schedule the transport block, one TTI is added to
the counter including the TTI of retransmission TB.

Updated

The counter is increased by 1 when the eNodeB uplink scheduler schedule


the transport block.

10.1.6.3.7 C373343800 Nack Data Volume High Bit of UL TB Block


Definition

The counter is used to count the part of TBs transmitted on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB uplink scheduler get negative acknowledged for the
transmitted transport block by UE.

Explanation

The counter provides the part of TBs transmitted by UE to eNodeB


on the uplink.The total TBs = Cell UL Volume High + Cell UL Volume
Low.When the eNodeB get the UL TB HARQ feedback failures,the counter
is collected. That is excluded the retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB uplink


scheduler get negative acknowledged for the transmitted transport block
by UE.

10.1.6.3.8 C373343801 Nack Data Volume Low Bit of UL TB Block


Definition

The counter is used to count the other part of TBs transmitted on the uplink.

Sampling Interval

15 min
10-92

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB uplink scheduler get negative acknowledged for the
transmitted transport block by UE.

Explanation

The counter provides the other part of TBs transmitted by UE to eNodeB


on the uplink.The total TBs = Cell UL Volume High + Cell UL Volume
Low.When the eNodeB get the UL TB HARQ feedback failures,the counter
is collected. That is excluded the retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB uplink


scheduler get negative acknowledged for the transmitted transport block
by UE.

10.1.6.3.9 C373343802 Nack Data Volume High Bit of DL TB Block


Definition

The counter is used to count the part of TBs transmitted on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB downlink scheduler get negative acknowledged for the
transmitted transport block over the air.

Explanation

The counter provides the part of TBs transmitted by eNodeB to UE on


the downlink.The total TBs = Cell DL Volume High + Cell DL Volume
Low.When the eNodeB get the DL TB HARQ feedback failures,the counter
is collected. That is excluded the retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB downlink


scheduler get negative acknowledged for the transmitted transport block
over the air.

10.1.6.3.10 C373343803 Nack Data Volume Low Bit of DL TB Block


Definition

The counter is used to count the other part of TBs transmitted on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When the eNodeB downlink scheduler get negative acknowledged for the
transmitted transport block over the air.
10-93

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the other part of TBs transmitted by eNodeB to UE


on the downlink.The total TBs = Cell DL Volume High + Cell DL Volume
Low.When the eNodeB get the DL TB HARQ feedback failures,the counter
is collected. That is excluded the retransmission TBs.

Updated

The counter is increased by the size of TB when the eNodeB downlink


scheduler get negative acknowledged for the transmitted transport block
over the air.

10.1.7 IP Throughput
10.1.7.1 Flow Charts and Sampling Points
Throughput of PDCP SDU bits in downlink for packet sizes or data bursts that are large
enough to require transmissions to be split across several TTIs, by excluding transmission
of the last piece of data in a data burst. Only data transmission time is considered, i.e.
when data transmission over Uu has begun but not yet finished. Each measurement is a
real value representing the throughput in kbits/s. The measurement is performed per QCI
per UE. For successful reception, the reference point is MAC upper SAP.

10.1.7.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343738

DL Aggregated Volume High,QCI=1

C373343739

DL Aggregated Volume Low,QCI=1

C373343740

DL Aggregated Time, QCI=1

C373343741

DL Aggregated Volume High,QCI=2

C373343742

DL Aggregated Volume Low,QCI=2

C373343743

DL Aggregated Time, QCI=2

C373343744

DL Aggregated Volume High,QCI=3

C373343745

DL Aggregated Volume Low,QCI=3

C373343746

DL Aggregated Time, QCI=3

10

C373343747

DL Aggregated Volume High,QCI=4

11

C373343748

DL Aggregated Volume Low,QCI=4

12

C373343749

DL Aggregated Time, QCI=4

13

C373343750

DL Aggregated Volume High,QCI=5

14

C373343751

DL Aggregated Volume Low,QCI=5

15

C373343752

DL Aggregated Time, QCI=5


10-94

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
16

C373343753

DL Aggregated Volume High,QCI=6

17

C373343754

DL Aggregated Volume Low,QCI=6

18

C373343755

DL Aggregated Time, QCI=6

19

C373343756

DL Aggregated Volume High,QCI=7

20

C373343757

DL Aggregated Volume Low,QCI=7

21

C373343758

DL Aggregated Time, QCI=7

22

C373343759

DL Aggregated Volume High,QCI=8

23

C373343760

DL Aggregated Volume Low,QCI=8

24

C373343761

DL Aggregated Time, QCI=8

25

C373343762

DL Aggregated Volume High,QCI=9

26

C373343763

DL Aggregated Volume Low,QCI=9

27

C373343764

DL Aggregated Time, QCI=9

28

C373343765

UL Aggregated Volume High,QCI=1

29

C373343766

UL Aggregated Volume Low,QCI=1

30

C373343767

UL Aggregated Time, QCI=1

31

C373343768

UL Aggregated Volume High,QCI=2

32

C373343769

UL Aggregated Volume Low,QCI=2

33

C373343770

UL Aggregated Time, QCI=2

34

C373343771

UL Aggregated Volume High,QCI=3

35

C373343772

UL Aggregated Volume Low,QCI=3

36

C373343773

UL Aggregated Time, QCI=3

37

C373343774

UL Aggregated Volume High,QCI=4

38

C373343775

UL Aggregated Volume Low,QCI=4

39

C373343776

UL Aggregated Time, QCI=4

40

C373343777

UL Aggregated Volume High,QCI=5

41

C373343778

UL Aggregated Volume Low,QCI=5

42

C373343779

UL Aggregated Time, QCI=5

43

C373343780

UL Aggregated Volume High,QCI=6

44

C373343781

UL Aggregated Volume Low,QCI=6

45

C373343782

UL Aggregated Time, QCI=6

46

C373343783

UL Aggregated Volume High,QCI=7

47

C373343784

UL Aggregated Volume Low,QCI=7

10-95
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
48

C373343785

UL Aggregated Time, QCI=7

49

C373343786

UL Aggregated Volume High,QCI=8

50

C373343787

UL Aggregated Volume Low,QCI=8

51

C373343788

UL Aggregated Time, QCI=8

52

C373343789

UL Aggregated Volume High,QCI=9

53

C373343790

UL Aggregated Volume Low,QCI=9

54

C373343791

UL Aggregated Time, QCI=9

55

C373343804

UL Aggregated Volume High

56

C373343805

UL Aggregated Volume Low

57

C373343806

DL Aggregated Volume High through Uu

58

C373343807

DL Aggregated Volume Low through Uu

10.1.7.3 Counter Description


10.1.7.3.1 C373343738 DL Aggregated Volume High,QCI=1
Definition

The counter is used to count the cell part bit-size of QCI1 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI1 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI1 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI1 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10-96
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.7.3.2 C373343739 DL Aggregated Volume Low,QCI=1


Definition

The counter is used to count the cell part bit-size of QCI1 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI1 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI1 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI1 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.3 C373343740 DL Aggregated Time, QCI=1


Definition

The counter is used to count the time to transmit a QCI1 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI1 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI1 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

The counter is incremented by the time of QCI1 PDCP SDU collected


at sampling time.

10.1.7.3.4 C373343741 DL Aggregated Volume High,QCI=2


Definition

The counter is used to count the cell part bit-size of QCI2 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

10-97
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI2 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI2 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI2 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.5 C373343742 DL Aggregated Volume Low,QCI=2


Definition

The counter is used to count the cell part bit-size of QCI2 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI2 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI2 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI2 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.6 C373343743 DL Aggregated Time, QCI=2


Definition

The counter is used to count the time to transmit a QCI2 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

10-98
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When a QCI2 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI2 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI2 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.7 C373343744 DL Aggregated Volume High,QCI=3


Definition

The counter is used to count the cell part bit-size of QCI3 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI3 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI3 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI3 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.8 C373343745 DL Aggregated Volume Low,QCI=3


Definition

The counter is used to count the cell part bit-size of QCI3 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI3 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

10-99
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the other part volume of QCI3 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI3 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.9 C373343746 DL Aggregated Time, QCI=3


Definition

The counter is used to count the time to transmit a QCI3 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI3 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI3 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI3 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.10 C373343747 DL Aggregated Volume High,QCI=4


Definition

The counter is used to count the cell part bit-size of QCI4 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI4 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI4 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

10-100
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

When all packets of a QCI4 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.11 C373343748 DL Aggregated Volume Low,QCI=4


Definition

The counter is used to count the cell part bit-size of QCI4 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI4 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI4 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI4 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.12 C373343749 DL Aggregated Time, QCI=4


Definition

The counter is used to count the time to transmit a QCI4 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI4 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI4 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI4 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10-101
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.7.3.13 C373343750 DL Aggregated Volume High,QCI=5


Definition

The counter is used to count the cell part bit-size of QCI5 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI5 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI5 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI5 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.14 C373343751 DL Aggregated Volume Low,QCI=5


Definition

The counter is used to count the cell part bit-size of QCI5 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI5 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI5 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI5 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10-102
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.7.3.15 C373343752 DL Aggregated Time, QCI=5


Definition

The counter is used to count the time to transmit a QCI5 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI5 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI5 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI5 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.16 C373343753 DL Aggregated Volume High,QCI=6


Definition

The counter is used to count the cell part bit-size of QCI6 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI6 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI6 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI6 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.17 C373343754 DL Aggregated Volume Low,QCI=6


Definition

The counter is used to count the cell part bit-size of QCI6 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

10-103
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI6 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI6 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI6 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.18 C373343755 DL Aggregated Time, QCI=6


Definition

The counter is used to count the time to transmit a QCI6 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI6 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI6 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI6 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.19 C373343756 DL Aggregated Volume High,QCI=7


Definition

The counter is used to count the cell part bit-size of QCI7 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI7 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

10-104
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

The counter provides the part volume of QCI7 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI7 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.20 C373343757 DL Aggregated Volume Low,QCI=7


Definition

The counter is used to count the cell part bit-size of QCI7 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI7 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI7 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI7 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.21 C373343758 DL Aggregated Time, QCI=7


Definition

The counter is used to count the time to transmit a QCI7 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI7 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI7 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

10-105
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

When a QCI7 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.22 C373343759 DL Aggregated Volume High,QCI=8


Definition

The counter is used to count the cell part bit-size of QCI8 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI8 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI8 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI8 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.23 C373343760 DL Aggregated Volume Low,QCI=8


Definition

The counter is used to count the cell part bit-size of QCI8 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI8 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI8 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI8 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10-106
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.7.3.24 C373343761 DL Aggregated Time, QCI=8


Definition

The counter is used to count the time to transmit a QCI8 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI8 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI8 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI8 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.25 C373343762 DL Aggregated Volume High,QCI=9


Definition

The counter is used to count the cell part bit-size of QCI9 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI9 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of QCI9 PDCP SDU transmitted by
eNodeB to UE on the downlink.The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a QCI9 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.26 C373343763 DL Aggregated Volume Low,QCI=9


Definition

The counter is used to count the cell part bit-size of QCI9 PDCP SDUs
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

10-107
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a QCI9 PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of QCI9 PDCP SDU
transmitted by eNodeB to UE on the downlink. The total volume = volume
High + Volume Low. When the eNodeB get the successful DL TB HARQ
feedback and all frag of PDCP SDU related to TB have been transmitted to
the air interface successfully,the counter is collected.

Updated

When all packets of a QCI9 PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.27 C373343764 DL Aggregated Time, QCI=9


Definition

The counter is used to count the time to transmit a QCI9 data burst on
the downlink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI9 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink.

Explanation

The eNodeB collects the time of QCI9 traffic buffer from buffered data to
empty on the downlink on the downlink at sampling period.

Updated

When a QCI9 PDCP SDU are scheduled by the eNodeB over air interface
on the downlink,the counter is incremented by 1.

10.1.7.3.28 C373343765 UL Aggregated Volume High,QCI=1


Definition

The counter is used to count the cell part bit-size of QCI1 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI1 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI1 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.
10-108

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

When a QCI1 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.29 C373343766 UL Aggregated Volume Low,QCI=1


Definition

The counter is used to count the cell part bit-size of QCI1 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI1 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI1 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI1 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.30 C373343767 UL Aggregated Time, QCI=1


Definition

The counter is used to count the time to transmit a QCI1 data burst on
the uplink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI1 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI1 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

The counter is incremented by the time of QCI1 PDCP SDU collected


at sampling time.

10.1.7.3.31 C373343768 UL Aggregated Volume High,QCI=2


Definition

The counter is used to count the cell part bit-size of QCI2 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

10-109
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI2 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI2 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI2 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.32 C373343769 UL Aggregated Volume Low,QCI=2


Definition

The counter is used to count the cell part bit-size of QCI2 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI2 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI2 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI2 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.33 C373343770 UL Aggregated Time, QCI=2


Definition

The counter is used to count the time to transmit a QCI2 data burst on
the uplink

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI2 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI2 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI2 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10-110
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.7.3.34 C373343771 UL Aggregated Volume High,QCI=3


Definition

The counter is used to count the cell part bit-size of QCI3 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI3 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI3 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI3 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.35 C373343772 UL Aggregated Volume Low,QCI=3


Definition

The counter is used to count the cell part bit-size of QCI3 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI3 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI3 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI3 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.36 C373343773 UL Aggregated Time, QCI=3


Definition

The counter is used to count the time to transmit a QCI3 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

10-111
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When a QCI3 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI3 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI3 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10.1.7.3.37 C373343774 UL Aggregated Volume High,QCI=4


Definition

The counter is used to count the cell part bit-size of QCI4 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI4 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI4 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI4 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.38 C373343775 UL Aggregated Volume Low,QCI=4


Definition

The counter is used to count the cell part bit-size of QCI4 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI4 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI4 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI4 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10-112
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.1.7.3.39 C373343776 UL Aggregated Time, QCI=4


Definition

The counter is used to count the time to transmit a QCI4 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI4 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI4 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI4 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10.1.7.3.40 C373343777 UL Aggregated Volume High,QCI=5


Definition

The counter is used to count the cell part bit-size of QCI5 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI5 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI5 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI5 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.41 C373343778 UL Aggregated Volume Low,QCI=5


Definition

The counter is used to count the cell part bit-size of QCI5 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI5 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.
10-113

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the other part volume of QCI5 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI5 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.42 C373343779 UL Aggregated Time, QCI=5


Definition

The counter is used to count the time to transmit a QCI5 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI5 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI5 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI5 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10.1.7.3.43 C373343780 UL Aggregated Volume High,QCI=6


Definition

The counter is used to count the cell part bit-size of QCI6 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI6 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI6 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI6 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.44 C373343781 UL Aggregated Volume Low,QCI=6


Definition

The counter is used to count the cell part bit-size of QCI6 PDCP SDUs
on the uplink.

Sampling Interval

15 min
10-114

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI6 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI6 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI6 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.45 C373343782 UL Aggregated Time, QCI=6


Definition

The counter is used to count the time to transmit a QCI6 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI6 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI6 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI6 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10.1.7.3.46 C373343783 UL Aggregated Volume High,QCI=7


Definition

The counter is used to count the cell part bit-size of QCI7 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI7 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI7 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

10-115
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

When a QCI7 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.47 C373343784 UL Aggregated Volume Low,QCI=7


Definition

The counter is used to count the cell part bit-size of QCI7 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI7 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI7 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI7 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.48 C373343785 UL Aggregated Time, QCI=7


Definition

The counter is used to count the time to transmit a QCI7 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI7 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI7 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI7 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10.1.7.3.49 C373343786 UL Aggregated Volume High,QCI=8


Definition

The counter is used to count the cell part bit-size of QCI8 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

10-116
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI8 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI8 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI8 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.50 C373343787 UL Aggregated Volume Low,QCI=8


Definition

The counter is used to count the cell part bit-size of QCI8 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI8 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI8 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI8 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.51 C373343788 UL Aggregated Time, QCI=8


Definition

The counter is used to count the time to transmit a QCI8 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When a QCI8 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI8 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI8 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10-117
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.7.3.52 C373343789 UL Aggregated Volume High,QCI=9


Definition

The counter is used to count the cell part bit-size of QCI9 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI9 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the part volume of QCI9 PDCP SDU transmitted by
eNodeB to UE on the uplink.The total volume = volume High + Volume Low.

Updated

When a QCI9 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.53 C373343790 UL Aggregated Volume Low,QCI=9


Definition

The counter is used to count the cell part bit-size of QCI9 PDCP SDUs
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a QCI9 PDCP SDU are received by PDCP layer from RLC layer
on the uplink.

Explanation

The counter provides the other part volume of QCI9 PDCP SDU
transmitted by eNodeB to UE on the uplink. The total volume = volume
High + Volume Low.

Updated

When a QCI9 PDCP SDU are received by PDCP layer from RLC layer on
the uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.54 C373343791 UL Aggregated Time, QCI=9


Definition

The counter is used to count the time to transmit a QCI9 data burst on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

10-118
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When a QCI9 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink.

Explanation

The eNodeB collects the time of QCI9 traffic buffer from buffered data to
empty on the uplink at sampling period.

Updated

When a QCI9 PDCP SDU are scheduled by the eNodeB over air interface
on the uplink,the counter is incremented by 1.

10.1.7.3.55 C373343804 UL Aggregated Volume High


Definition

The counter is used to count the cell part bit-size of PDCP SDUs on the
uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When a PDCP SDU are received by PDCP layer from RLC layer on the
uplink.

Explanation

The counter provides the part volume of PDCP SDU transmitted by


eNodeB to UE on the uplink. The total volume = volume High + Volume
Low.

Updated

When a PDCP SDU are received by PDCP layer from RLC layer on the
uplink,the counter is incremented by the bit-size of the PDCP SDU.

10.1.7.3.56 C373343805 UL Aggregated Volume Low


Definition

The counter is used to count the cell part bit-size of PDCP SDUs on the
uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Kbit

Measurement Object

Cell

Sampling Point

When a PDCP SDU are received by PDCP layer from RLC layer on the
uplink.

Explanation

The counter provides the other part volume of PDCP SDU transmitted by
eNodeB to UE on the uplink. The total volume = volume High + Volume
Low.

Updated

When a PDCP SDU are received by PDCP layer from RLC layer on the
uplink,the counter is incremented by the bit-size of the PDCP SDU.

10-119
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.1.7.3.57 C373343806 DL Aggregated Volume High through Uu


Definition

The counter is used to count the cell part bit-size of PDCP SDUs on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Mbit

Measurement Object

Cell

Sampling Point

When all packets of a PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the part volume of PDCP SDU transmitted by


eNodeB to UE on the downlink. The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully, the counter is collected.

Updated

When all packets of a PDCP SDU are sent by the eNodeB over air
interface on the downlink, the counter is incremented by the bit-size of
the PDCP SDU.

10.1.7.3.58 C373343807 DL Aggregated Volume Low through Uu


Definition

The counter is used to count the cell part bit-size of PDCP SDUs on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Kbit

Measurement Object

Cell

Sampling Point

When all packets of a PDCP SDU are sent by the eNodeB over air
interface on the downlink.

Explanation

The counter provides the other part volume of PDCP SDU transmitted by
eNodeB to UE on the downlink. The total volume = volume High + Volume
Low. When the eNodeB get the successful DL TB HARQ feedback and all
frag of PDCP SDU related to TB have been transmitted to the air interface
successfully,the counter is collected.

Updated

When all packets of a PDCP SDU are sent by the eNodeB over air
interface on the downlink,the counter is incremented by the bit-size of
the PDCP SDU.

10-120
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.2 Traffic Delay on Cell


10.2.1 IP Latency on Cell
10.2.1.1 Flow Charts and Sampling Points
Figure 10-4 IP Latency

10.2.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373364109

DL QCI1 IP Packet Delay

C373364110

DL QCI2 IP Packet Delay

C373364111

DL QCI3 IP Packet Delay

C373364112

DL QCI4 IP Packet Delay

C373364113

DL QCI5 IP Packet Delay

C373364114

DL QCI6 IP Packet Delay

C373364115

DL QCI7 IP Packet Delay

C373364116

DL QCI8 IP Packet Delay

C373364117

DL QCI9 IP Packet Delay

10

C373364119

DL IP Packet Delay

10.2.1.3 Counter Description


10.2.1.3.1 C373364109 DL QCI1 IP Packet Delay
Definition

The counter is used to count IP Latency of QCI1 packets in DL.


10-121

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI1 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI1 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI1 PDCP SDU over the air.

10.2.1.3.2 C373364110 DL QCI2 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI2 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI2 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI2 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI2 PDCP SDU over the air.

10.2.1.3.3 C373364111 DL QCI3 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI3 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

10-122
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

The eNodeB records the start time at receiving the QCI3 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI3 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI3 PDCP SDU over the air.

10.2.1.3.4 C373364112 DL QCI4 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI4 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI4 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI4 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI4 PDCP SDU over the air.

10.2.1.3.5 C373364113 DL QCI5 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI5 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI5 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

10-123
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When a QCI5 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI5 PDCP SDU over the air.

10.2.1.3.6 C373364114 DL QCI6 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI6 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI6 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI6 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI6 PDCP SDU over the air.

10.2.1.3.7 C373364115 DL QCI7 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI7 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI7 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI7 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI7 PDCP SDU over the air.

10-124
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.2.1.3.8 C373364116 DL QCI8 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI8 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI8 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI8 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI8 PDCP SDU over the air.

10.2.1.3.9 C373364117 DL QCI9 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI9 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI9 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI9 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI9 PDCP SDU over the air.

10.2.1.3.10 C373364119 DL IP Packet Delay


Definition

The counter is used to count IP Latency of packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

10-125
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the PDCP SDU, and than
records the end time at sending the first part of the PDCP SDU over the air.

Explanation

When a PDCP SDU arrives the eNodeB PDCP layer, it is the start point in
time.When the first piece of PDCP SDU was was sent to air interface,it is
the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the PDCP SDU over the air.

10.2.2 PDCP SDU DL Delay on Cell


10.2.2.1 Flow Charts and Sampling Points
No chart.

10.2.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373364100

DL QCI1 PDCP SDU Delay

C373364101

DL QCI2 PDCP SDU Delay

C373364102

DL QCI3 PDCP SDU Delay

C373364103

DL QCI4 PDCP SDU Delay

C373364104

DL QCI5 PDCP SDU Delay

C373364105

DL QCI6 PDCP SDU Delay

C373364106

DL QCI7 PDCP SDU Delay

C373364107

DL QCI8 PDCP SDU Delay

C373364108

DL QCI9 PDCP SDU Delay

10

C373364118

DL PDCP SDU Delay

10.2.2.3 Counter Description


10.2.2.3.1 C373364100 DL QCI1 PDCP SDU Delay
Definition

The counter is used to count the average QCI1 PDCP SDU delay on the
downlink.

Sampling Interval

15 min
10-126

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI1 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI1 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI1 PDCP SDU.

10.2.2.3.2 C373364101 DL QCI2 PDCP SDU Delay


Definition

The counter is used to count the average QCI2 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI2 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI2 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI2 PDCP SDU.

10.2.2.3.3 C373364102 DL QCI3 PDCP SDU Delay


Definition

The counter is used to count the average QCI3 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

10-127
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI3 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI3 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI3 PDCP SDU.

10.2.2.3.4 C373364103 DL QCI4 PDCP SDU Delay


Definition

The counter is used to count the average QCI4 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI4 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI4 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI4 PDCP SDU.

10.2.2.3.5 C373364104 DL QCI5 PDCP SDU Delay


Definition

The counter is used to count the average QCI5 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

10-128
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

The eNodeB records the start time at receiving the QCI5 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI5 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI5 PDCP SDU.

10.2.2.3.6 C373364105 DL QCI6 PDCP SDU Delay


Definition

The counter is used to count the average QCI6 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI6 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI6 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI6 PDCP SDU.

10.2.2.3.7 C373364106 DL QCI7 PDCP SDU Delay


Definition

The counter is used to count the average QCI7 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI7 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.
10-129

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When a QCI7 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI7 PDCP SDU.

10.2.2.3.8 C373364107 DL QCI8 PDCP SDU Delay


Definition

The counter is used to count the average QCI8 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI8 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI8 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI8 PDCP SDU.

10.2.2.3.9 C373364108 DL QCI9 PDCP SDU Delay


Definition

The counter is used to count the average QCI9 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the QCI9 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

10-130
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When a QCI9 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI9 PDCP SDU.

10.2.2.3.10 C373364118 DL PDCP SDU Delay


Definition

The counter is used to count the average PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

The eNodeB records the start time at receiving the PDCP SDU, and than
records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a PDCP SDU arrives the eNodeB PDCP layer,it is the start point in
time.When the last piece of PDCP SDU was received by the UE according
to received HARQ feedback information,it is the end point in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the PDCP SDU.

10.2.3 Call Duration Before Drop on Cell


10.2.3.1 Flow Charts and Sampling Points
No chart.

10.2.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373343796

Call Time before Drop, QCI=1

C373343797

Call Time before Drop, QCI=2

C373343798

Call Time before Drop, QCI=3

C373343799

Call Time before Drop, QCI=4


10-131

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.2.3.3 Counter Description


10.2.3.3.1 C373343796 Call Time before Drop, QCI=1
Definition

The counter is used to count the call duration of QCI1 E-RABs before
dropping.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a data radio bearer with QCI = 1 is initiated to release by eNodeB.

Explanation

After a data radio bearer with QCI = 1 is successfully setup, the eNodeB
start to detect the active session time of the bearer. When the bearer is
initiated to release by eNodeB, report the total session time of it. The
counter provides the number of atcivity session time.

Updated

When a data radio bearer with QCI = 1 is initiated to release by eNodeB,the


counter is increased by the in-session activity time for the bearer.

10.2.3.3.2 C373343797 Call Time before Drop, QCI=2


Definition

The counter is used to count the call duration of QCI2 E-RABs before
dropping.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a data radio bearer with QCI = 2 is initiated to release by eNodeB.

Explanation

After a data radio bearer with QCI = 2 is successfully setup, the eNodeB
start to detect the active session time of the bearer. When the bearer
is initiated to release by eNodeB, report the total session time of it.The
counter provides the number of atcivity session time.

Updated

When a data radio bearer with QCI = 2 is initiated to release by eNodeB,the


counter is increased by the in-session activity time for the bearer.

10.2.3.3.3 C373343798 Call Time before Drop, QCI=3


Definition

The counter is used to count the call duration of QCI3 E-RABs before
dropping.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit
10-132

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Measurement Object

Cell

Sampling Point

When a data radio bearer with QCI = 3 is initiated to release by eNodeB.

Explanation

After a data radio bearer with QCI = 3 is successfully setup, the eNodeB
start to detect the active session time of the bearer. When the bearer is
initiated to release by eNodeB, report the total session time of it. The
counter provides the number of atcivity session time.

Updated

When a data radio bearer with QCI = 3 is initiated to release by eNodeB,the


counter is increased by the in-session activity time for the bearer.

10.2.3.3.4 C373343799 Call Time before Drop, QCI=4


Definition

The counter is used to count the call duration of QCI4 E-RABs before
dropping.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When a data radio bearer with QCI = 4 is initiated to release by eNodeB.

Explanation

After a data radio bearer with QCI = 4 is successfully setup, the eNodeB
start to detect the active session time of the bearer. When the bearer is
initiated to release by eNodeB, report the total session time of it. The
counter provides the number of atcivity session time.

Updated

When a data radio bearer with QCI = 4 is initiated to release by eNodeB,the


counter is increased by the in-session activity time for the bearer.

10.3 Loss Packet on Cell


10.3.1 PDCP SDU Loss Packet on Cell
10.3.1.1 Flow Charts and Sampling Points
No chart.

10.3.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373353900

UL PDCP SDU Loss Number, QCI=1

C373353901

UL PDCP SDU Loss Number, QCI=2


10-133

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
3

C373353902

UL PDCP SDU Loss Number, QCI=3

C373353903

UL PDCP SDU Loss Number, QCI=4

C373353904

UL PDCP SDU Loss Number, QCI=5

C373353905

UL PDCP SDU Loss Number, QCI=6

C373353906

UL PDCP SDU Loss Number, QCI=7

C373353907

UL PDCP SDU Loss Number, QCI=8

C373353908

UL PDCP SDU Loss Number, QCI=9

10

C373353909

DL PDCP SDU Loss Number, QCI=1

11

C373353910

DL PDCP SDU Loss Number, QCI=2

12

C373353911

DL PDCP SDU Loss Number, QCI=3

13

C373353912

DL PDCP SDU Loss Number, QCI=4

14

C373353913

DL PDCP SDU Loss Number, QCI=5

15

C373353914

DL PDCP SDU Loss Number, QCI=6

16

C373353915

DL PDCP SDU Loss Number, QCI=7

17

C373353916

DL PDCP SDU Loss Number, QCI=8

18

C373353917

DL PDCP SDU Loss Number, QCI=9

19

C373353956

UL PDCP SDU Loss Number

20

C373353957

DL PDCP SDU Loss Number

10.3.1.3 Counter Description


10.3.1.3.1 C373353900 UL PDCP SDU Loss Number, QCI=1
Definition

The counter is used to count the number of QCI1 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI1 PDCP SDU sequece number
discontinuity in UL.

10-134
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When the eNodeB PDCP layer receives the QCI1 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI1 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.2 C373353901 UL PDCP SDU Loss Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI2 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI2 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI2 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.3 C373353902 UL PDCP SDU Loss Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI3 PDCP SDU sequece number
discontinuity in UL.

10-135
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB PDCP layer receives the QCI3 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI3 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.4 C373353903 UL PDCP SDU Loss Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI4 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI4 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI4 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.5 C373353904 UL PDCP SDU Loss Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI5 PDCP SDU sequece number
discontinuity in UL.

10-136
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When the eNodeB PDCP layer receives the QCI5 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI5 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.6 C373353905 UL PDCP SDU Loss Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI6 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI6 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI6 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.7 C373353906 UL PDCP SDU Loss Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI7 PDCP SDU sequece number
discontinuity in UL.

10-137
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB PDCP layer receives the QCI7 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI7 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.8 C373353907 UL PDCP SDU Loss Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI8 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI8 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI8 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.9 C373353908 UL PDCP SDU Loss Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the QCI9 PDCP SDU sequece number
discontinuity in UL.

10-138
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When the eNodeB PDCP layer receives the QCI9 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI9 UL PDCP SDU sequece
number discontinuity.

10.3.1.3.10 C373353909 DL PDCP SDU Loss Number, QCI=1


Definition

The counter is used to count the number of QCI1 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI1 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI1 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI1 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.11 C373353910 DL PDCP SDU Loss Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI2 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

10-139
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

the eNodeB discards the QCI2 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI2 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.12 C373353911 DL PDCP SDU Loss Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI3 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI3 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI3 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.13 C373353912 DL PDCP SDU Loss Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI4 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI4 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

10-140
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is increased by 1 when the eNodeB discards the QCI4 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.14 C373353913 DL PDCP SDU Loss Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI5 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI5 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI5 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.15 C373353914 DL PDCP SDU Loss Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI6 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI6 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI6 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10-141
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.3.1.3.16 C373353915 DL PDCP SDU Loss Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI7 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI7 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI7 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.17 C373353916 DL PDCP SDU Loss Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI8 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI8 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI8 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.18 C373353917 DL PDCP SDU Loss Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min
10-142

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI9 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI9 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI9 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.3.1.3.19 C373353956 UL PDCP SDU Loss Number


Definition

The counter is used to count the number of PDCP SDU that are lost on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB detects the PDCP SDU sequece number discontinuity
in UL.

Explanation

When the eNodeB PDCP layer receives the PDCP PDU from the RLC
layer, compare the received PDU sequence number with the expected
sequence number. If the received is larger than the expected, it is
considered that there is packet loss in UL. The number of the lost SDU is
the difference between the received sequence number and the expected
sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the UL PDCP SDU sequece number
discontinuity.

10.3.1.3.20 C373353957 DL PDCP SDU Loss Number


Definition

The counter is used to count the number of packets that are lost at Uu
transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

10-143
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB discards the PDCP SDU in DL, for which at least a part
has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the PDCP SDU
in DL, for which at least a part has been transmitted over the air but not
positively acknowledged.

10.3.2 PDCP SDU Discard Packet on Cell


10.3.2.1 Flow Charts and Sampling Points
No chart.

10.3.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373353918

DL PDCP SDU Discard Number, QCI=1

C373353919

DL PDCP SDU Discard Number, QCI=2

C373353920

DL PDCP SDU Discard Number, QCI=3

C373353921

DL PDCP SDU Discard Number, QCI=4

C373353922

DL PDCP SDU Discard Number, QCI=5

C373353923

DL PDCP SDU Discard Number, QCI=6

C373353924

DL PDCP SDU Discard Number, QCI=7

C373353925

DL PDCP SDU Discard Number, QCI=8

C373353926

DL PDCP SDU Discard Number, QCI=9

10

C373353958

DL PDCP SDU Discard Number

10.3.2.3 Counter Description


10.3.2.3.1 C373353918 DL PDCP SDU Discard Number, QCI=1
Definition

The counter is used to count the number of QCI1 packets that are dropped
due to congestion, traffic management etc.
10-144

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI1 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI1 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI1 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.2 C373353919 DL PDCP SDU Discard Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI2 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI2 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI2 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.3 C373353920 DL PDCP SDU Discard Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI3 PDCP SDU in DL, for which no part
has been transmitted over the air.

10-145
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

the eNodeB discards the QCI3 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI3 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.4 C373353921 DL PDCP SDU Discard Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI4 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI4 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI4 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.5 C373353922 DL PDCP SDU Discard Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI5 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI5 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI5 PDCP
SDU in DL, for which no part has been transmitted over the air.

10-146
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.3.2.3.6 C373353923 DL PDCP SDU Discard Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI6 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI6 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI6 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.7 C373353924 DL PDCP SDU Discard Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI7 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI7 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI7 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.8 C373353925 DL PDCP SDU Discard Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
10-147

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB discards the QCI8 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI8 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI8 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.9 C373353926 DL PDCP SDU Discard Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the QCI9 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB will discard the QCI9 PDCP SDU and no part of which has
been transmitted over the air when "timer discard" timer of detecting the
SDU expires or there is no DL buffer for the SDU. The counter is used
to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB discards the QCI9 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.3.2.3.10 C373353958 DL PDCP SDU Discard Number


Definition

The counter is used to count the number of packets that are dropped due
to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB discards the PDCP SDU in DL, for which no part has
been transmitted over the air.

Explanation

the eNodeB discards the PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the PDCP SDU
in DL, for which no part has been transmitted over the air.
10-148

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.3.3 PDCP SDU Total Number on Cell


10.3.3.1 Flow Charts and Sampling Points
No chart.

10.3.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373353927

UL PDCP SDU Number, QCI=1

C373353928

UL PDCP SDU Number, QCI=2

C373353929

UL PDCP SDU Number, QCI=3

C373353930

UL PDCP SDU Number, QCI=4

C373353931

UL PDCP SDU Number, QCI=5

C373353932

UL PDCP SDU Number, QCI=6

C373353933

UL PDCP SDU Number, QCI=7

C373353934

UL PDCP SDU Number, QCI=8

C373353935

UL PDCP SDU Number, QCI=9

10

C373353936

DL PDCP SDU Number, QCI=1

11

C373353937

DL PDCP SDU Number, QCI=2

12

C373353938

DL PDCP SDU Number, QCI=3

13

C373353939

DL PDCP SDU Number, QCI=4

14

C373353940

DL PDCP SDU Number, QCI=5

15

C373353941

DL PDCP SDU Number, QCI=6

16

C373353942

DL PDCP SDU Number, QCI=7

17

C373353943

DL PDCP SDU Number, QCI=8

18

C373353944

DL PDCP SDU Number, QCI=9

19

C373353947

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=1

20

C373353948

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=2

21

C373353949

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=3

22

C373353950

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=4

23

C373353951

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=5

24

C373353952

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=6

25

C373353953

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=7

26

C373353954

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=8

10-149
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
27

C373353955

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=9

28

C373353959

UL PDCP SDU Number

29

C373353960

DL PDCP SDU Number

30

C373353961

DL PDCP SDU Number Which HARQ Successfully Responds

10.3.3.3 Counter Description


10.3.3.3.1 C373353927 UL PDCP SDU Number, QCI=1
Definition

The counter is used to count the number of QCI1 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI1 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI1 PDCP packet in the uplink.

10.3.3.3.2 C373353928 UL PDCP SDU Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI2 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI2 PDCP packet in the uplink.
10-150

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.3.3.3.3 C373353929 UL PDCP SDU Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI3 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI3 PDCP packet in the uplink.

10.3.3.3.4 C373353930 UL PDCP SDU Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI4 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI4 PDCP packet in the uplink.

10.3.3.3.5 C373353931 UL PDCP SDU Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 PDCP packet in the uplink.

10-151
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After the PDCP layer receives the QCI5 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI5 PDCP packet in the uplink.

10.3.3.3.6 C373353932 UL PDCP SDU Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI6 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI6 PDCP packet in the uplink.

10.3.3.3.7 C373353933 UL PDCP SDU Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI7 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI7 PDCP packet in the uplink.

10.3.3.3.8 C373353934 UL PDCP SDU Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min
10-152

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI8 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI8 PDCP packet in the uplink.

10.3.3.3.9 C373353935 UL PDCP SDU Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI9 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI9 PDCP packet in the uplink.

10.3.3.3.10 C373353936 DL PDCP SDU Number, QCI=1


Definition

The counter is used to count the number of QCI1 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI1 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI1 PDCP SDU from the SGW or the other eNodeB.

10-153
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.3.3.3.11 C373353937 DL PDCP SDU Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI2 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI2 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.12 C373353938 DL PDCP SDU Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI3 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI3 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.13 C373353939 DL PDCP SDU Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI4 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

10-154
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI4 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.14 C373353940 DL PDCP SDU Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI5 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI5 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.15 C373353941 DL PDCP SDU Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI6 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI6 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.16 C373353942 DL PDCP SDU Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI7 PDCP SDU.
10-155

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB PDCP layer receives the QCI7 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI7 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.17 C373353943 DL PDCP SDU Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI8 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI8 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.18 C373353944 DL PDCP SDU Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI9 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI9 PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.19 C373353947 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=1
Definition

The counter is used to count the number of QCI1 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative
10-156

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI1 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI1 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.20 C373353948 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=2
Definition

The counter is used to count the number of QCI2 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI2 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI2 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.21 C373353949 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=3
Definition

The counter is used to count the number of QCI3 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI3 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.
10-157

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI3 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.22 C373353950 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=4
Definition

The counter is used to count the number of QCI4 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI4 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI4 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.23 C373353951 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=5
Definition

The counter is used to count the number of QCI5 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI5 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI5 PDCP SDU,for which all parts have been
transmitted over the air.

10-158
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.3.3.3.24 C373353952 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=6
Definition

The counter is used to count the number of QCI6 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI6 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI6 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.25 C373353953 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=7
Definition

The counter is used to count the number of QCI7 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI7 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI7 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.26 C373353954 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=8
Definition

The counter is used to count the number of QCI8 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative
10-159

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI8 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI8 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.27 C373353955 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=9
Definition

The counter is used to count the number of QCI9 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI9 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI9 PDCP SDU,for which all parts have been
transmitted over the air.

10.3.3.3.28 C373353959 UL PDCP SDU Number


Definition

The counter is used to count the number of packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer sends the PDCP packet in the uplink.

Explanation

After the PDCP layer receives the PDCP PDU from RLC layer,the PDU is
disposed successfully and than becomes PDCP SDU. The counter is used
to count the number of the SDU.

10-160
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
PDCP packet in the uplink.

10.3.3.3.29 C373353960 DL PDCP SDU Number


Definition

The counter is used to count the number of packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB PDCP layer receives the PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the PDCP SDU from the SGW or
the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
PDCP SDU from the SGW or the other eNodeB.

10.3.3.3.30 C373353961 DL PDCP SDU Number Which HARQ Successfully Responds


Definition

The counter is used to count the number of PDCP SDUs that the last piece
was received by the UE according to received HARQ feedback information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about PDCP SDU,for which all parts have been
transmitted over the air.

10-161
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.4 User Number on Cell


10.4.1 Active User Number on Cell
10.4.1.1 Flow Charts and Sampling Points
No chart.

10.4.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373384300

Average UL Active User Number(QCI=1)

C373384301

Average UL Active User Number(QCI=2)

C373384302

Average UL Active User Number(QCI=3)

C373384303

Average UL Active User Number(QCI=4)

C373384304

Average UL Active User Number(QCI=5)

C373384305

Average UL Active User Number(QCI=6)

C373384306

Average UL Active User Number(QCI=7)

C373384307

Average UL Active User Number(QCI=8)

C373384308

Average UL Active User Number(QCI=9)

10

C373384309

Average DL Active User Number(QCI=1)

11

C373384310

Average DL Active User Number(QCI=2)

12

C373384311

Average DL Active User Number(QCI=3)

13

C373384312

Average DL Active User Number(QCI=4)

14

C373384313

Average DL Active User Number(QCI=5)

15

C373384314

Average DL Active User Number(QCI=6)

16

C373384315

Average DL Active User Number(QCI=7)

17

C373384316

Average DL Active User Number(QCI=8)

18

C373384317

Average DL Active User Number(QCI=9)

19

C373384318

Maximum UL Active User Number(QCI=1)

20

C373384319

Maximum UL Active User Number(QCI=2)

21

C373384320

Maximum UL Active User Number(QCI=3)

22

C373384321

Maximum UL Active User Number(QCI=4)

23

C373384322

Maximum UL Active User Number(QCI=5)

24

C373384323

Maximum UL Active User Number(QCI=6)

10-162
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
25

C373384324

Maximum UL Active User Number(QCI=7)

26

C373384325

Maximum UL Active User Number(QCI=8)

27

C373384326

Maximum UL Active User Number(QCI=9)

28

C373384327

Maximum DL Active User Number(QCI=1)

29

C373384328

Maximum DL Active User Number(QCI=2)

30

C373384329

Maximum DL Active User Number(QCI=3)

31

C373384330

Maximum DL Active User Number(QCI=4)

32

C373384331

Maximum DL Active User Number(QCI=5)

33

C373384332

Maximum DL Active User Number(QCI=6)

34

C373384333

Maximum DL Active User Number(QCI=7)

35

C373384334

Maximum DL Active User Number(QCI=8)

36

C373384335

Maximum DL Active User Number(QCI=9)

37

C373384348

Maximum Active User Number on User Plane

38

C373384349

Average Active User Number on User Plane

10.4.1.3 Counter Description


10.4.1.3.1 C373384300 Average UL Active User Number(QCI=1)
Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 1,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 1
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI1 active


UEs, and then dividing the sum by the measurement period.

10-163
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.4.1.3.2 C373384301 Average UL Active User Number(QCI=2)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 2,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 2
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI2 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.3 C373384302 Average UL Active User Number(QCI=3)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 3,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 3
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI3 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.4 C373384303 Average UL Active User Number(QCI=4)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 4,and that have DTCH data queued on
the uplink.
10-164

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 4
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI4 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.5 C373384304 Average UL Active User Number(QCI=5)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 5,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 5
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI5 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.6 C373384305 Average UL Active User Number(QCI=6)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 6,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell
10-165

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 6
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI6 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.7 C373384306 Average UL Active User Number(QCI=7)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 7,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 7
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI7 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.8 C373384307 Average UL Active User Number(QCI=8)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 8,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI8 DRB at sampling time.

10-166
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 8
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI8 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.9 C373384308 Average UL Active User Number(QCI=9)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 9,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 9
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI9 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.10 C373384309 Average DL Active User Number(QCI=1)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 1,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 1
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

10-167
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample DL QCI1 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.11 C373384310 Average DL Active User Number(QCI=2)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 2,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 2
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI2 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.12 C373384311 Average DL Active User Number(QCI=3)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 3,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 3
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI3 active


UEs, and then dividing the sum by the measurement period.

10-168
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.4.1.3.13 C373384312 Average DL Active User Number(QCI=4)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 4,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 4
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI4 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.14 C373384313 Average DL Active User Number(QCI=5)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 5,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 5
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI5 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.15 C373384314 Average DL Active User Number(QCI=6)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 6,and that have DTCH data queued on
the downlink.
10-169

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 6
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI6 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.16 C373384315 Average DL Active User Number(QCI=7)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 7,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 7
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI7 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.17 C373384316 Average DL Active User Number(QCI=8)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 8,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell
10-170

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 8
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI8 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.18 C373384317 Average DL Active User Number(QCI=9)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 9,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 9
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI9 active


UEs, and then dividing the sum by the measurement period.

10.4.1.3.19 C373384318 Maximum UL Active User Number(QCI=1)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 1,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI1 DRB at sampling time.

10-171
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 1 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
actives UEs is larger than the prior at sampling point.

10.4.1.3.20 C373384319 Maximum UL Active User Number(QCI=2)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 2,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 2 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
actives UEs is larger than the prior at sampling point.

10.4.1.3.21 C373384320 Maximum UL Active User Number(QCI=3)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 3,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 3 at sampling time.The counter provides the maximum value in the
measurement period.

10-172
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI3
actives UEs is larger than the prior at sampling point.

10.4.1.3.22 C373384321 Maximum UL Active User Number(QCI=4)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 4,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 4 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
actives UEs is larger than the prior at sampling point.

10.4.1.3.23 C373384322 Maximum UL Active User Number(QCI=5)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 5,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 5 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
actives UEs is larger than the prior at sampling point.

10-173
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.4.1.3.24 C373384323 Maximum UL Active User Number(QCI=6)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 6,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 6 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
actives UEs is larger than the prior at sampling point.

10.4.1.3.25 C373384324 Maximum UL Active User Number(QCI=7)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 7,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 7 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
actives UEs is larger than the prior at sampling point.

10.4.1.3.26 C373384325 Maximum UL Active User Number(QCI=8)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 8,and that have DTCH data
queued on the uplink.
10-174

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 8 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
actives UEs is larger than the prior at sampling point.

10.4.1.3.27 C373384326 Maximum UL Active User Number(QCI=9)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 9,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 9 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
actives UEs is larger than the prior at sampling point.

10.4.1.3.28 C373384327 Maximum DL Active User Number(QCI=1)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 1,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell
10-175

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 1 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
actives UEs is larger than the prior at sampling point.

10.4.1.3.29 C373384328 Maximum DL Active User Number(QCI=2)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 2,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 2 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
actives UEs is larger than the prior at sampling point.

10.4.1.3.30 C373384329 Maximum DL Active User Number(QCI=3)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 3,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI3 DRB at sampling time.

10-176
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 3 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
actives UEs is larger than the prior at sampling point.

10.4.1.3.31 C373384330 Maximum DL Active User Number(QCI=4)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 4,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 4 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
actives UEs is larger than the prior at sampling point.

10.4.1.3.32 C373384331 Maximum DL Active User Number(QCI=5)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 5,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 5 at sampling time.The counter provides the maximum value in the
measurement period.

10-177
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI5
actives UEs is larger than the prior at sampling point.

10.4.1.3.33 C373384332 Maximum DL Active User Number(QCI=6)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 6,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 6 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
actives UEs is larger than the prior at sampling point.

10.4.1.3.34 C373384333 Maximum DL Active User Number(QCI=7)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 7,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 7 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
actives UEs is larger than the prior at sampling point.

10-178
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.4.1.3.35 C373384334 Maximum DL Active User Number(QCI=8)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 8,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 8 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
actives UEs is larger than the prior at sampling point.

10.4.1.3.36 C373384335 Maximum DL Active User Number(QCI=9)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 9,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 9 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
actives UEs is larger than the prior at sampling point.

10.4.1.3.37 C373384348 Maximum Active User Number on User Plane


Definition

The counter is used to count the maximum number of UEs that have
DTCH data queued on the downlink or uplink.

Sampling Interval

100 ms
10-179

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in buffer at
sampling time.

Explanation

Number of UEs for which there is buffered data in MAC, RLC or PDCP
protocol layers for Data Radio Bearer of traffic class at sampling time. The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current actives
UEs is larger than the prior at sampling point.

10.4.1.3.38 C373384349 Average Active User Number on User Plane


Definition

The counter is used to count the average number of UEs that have DTCH
data queued on the downlink or the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs which has data in buffer at
sampling time.

Explanation

Number of UEs for which there is buffered data in MAC, RLC or


PDCP protocol layers for Data Radio Bearer of traffic class at sampling
time.The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by accumulating all the sample active UEs, and
then dividing the sum by the measurement period.

10.4.2 Active State Number on Cell


10.4.2.1 Flow Charts and Sampling Points
No chart.

10.4.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373384336

Maximum Active State User Number

10-180
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
2

C373384337

Minimum Active State User Number

C373384338

Average Active State User Number

C373970000

Number of Maximum Active State UE(Board)

C373970001

Number of Average Active State UE(Board)

10.4.2.3 Counter Description


10.4.2.3.1 C373384336 Maximum Active State User Number
Definition

The counter is used to count maximum number of UEs that the state is
"active".

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user is active
when having traffic and DRX high level.Otherwise the user is inactive.The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current active
state UEs is larger than the prior at sampling point.

10.4.2.3.2 C373384337 Minimum Active State User Number


Definition

The counter is used to count minimum number of UEs that the state is
"active".

Sampling Interval

100 ms

Counter Type

Minimum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

10-181
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user is active
when having traffic and DRX high level.Otherwise the user is inactive.The
counter provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current active
state UEs is smaller than the prior at sampling point.

10.4.2.3.3 C373384338 Average Active State User Number


Definition

The counter is used to count average number of UEs that the state is
"active".

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user
is active when having traffic and DRX high level.Otherwise the user is
inactive.The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by accumulating all the sample active state UEs,
and then dividing the sum by the measurement period.

10.4.2.3.4 C373970000 Number of Maximum Active State UE(Board)


Definition

The counter is used to count the maximum number of UEs which state
is "active" on board level.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

TBoard

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user is active
when having traffic and DRX high level.Otherwise the user is inactive.The
counter provides the maximum value in the measurement period.

Updated

When the eNodeB initiates the X2 self setup.

10-182
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.4.2.3.5 C373970001 Number of Average Active State UE(Board)


Definition

The counter is used to count the average number of UEs which state is
"active" on board level.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

TBoard

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user
is active when having traffic and DRX high level.Otherwise the user is
inactive.The counter provides the average value of all sampling point in the
measurement period.

Updated

When the eNodeB initiates the X2 self setup successfully.

10.4.3 Category User Number


10.4.3.1 Flow Charts and Sampling Points
No chart.

10.4.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373384343

Cat1 Average User Number

C373384344

Cat2 Average User Number

C373384345

Cat3 Average User Number

C373384346

Cat4 Average User Number

C373384347

Cat5 Average User Number

10.4.3.3 Counter Description


10.4.3.3.1 C373384343 Cat1 Average User Number
Definition

The counter is used to count average number of UEs with category = 1.

Sampling Interval

10 s
10-183

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs with category = 1 at sampling time.

Explanation

When eNodeB receives the UECapibilityInformation message from UE, it


gets the category of the UE. The number of cat1 user is incremented by
1 When the eNodeB sends the InitialContextSetupResponse message
to MME.
When eNodeB releases the UE Context triggered by MME or eNodeB,
the number is decremented by 1.

Updated

The counter is updated by accumulating all the sample UEs with category
= 1, and then dividing the sum by the measurement period.

10.4.3.3.2 C373384344 Cat2 Average User Number


Definition

The counter is used to count average number of UEs with category = 2.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs with category = 2 at sampling time.

Explanation

When eNodeB receives the UECapibilityInformation message from UE, it


gets the category of the UE. The number of cat2 user is incremented by
1 When the eNodeB sends the InitialContextSetupResponse message
to MME.
When eNodeB releases the Ue Context triggered by MME or eNodeB,
the number is decremented by 1.

Updated

The counter is updated by accumulating all the sample UEs with category
= 2, and then dividing the sum by the measurement period.

10.4.3.3.3 C373384345 Cat3 Average User Number


Definition

The counter is used to count average number of UEs with category = 3.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs with category = 3 at sampling time.

10-184
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When eNodeB receives the UECapibilityInformation message from UE, it


gets the category of the UE. The number of cat3 user is incremented by
1 When the eNodeB sends the InitialContextSetupResponse message
to MME.
When eNodeB releases the UE Context triggered by MME or eNodeB,
the number is decremented by 1.

Updated

The counter is updated by accumulating all the sample UEs with category
= 3, and then dividing the sum by the measurement period.

10.4.3.3.4 C373384346 Cat4 Average User Number


Definition

The counter is used to count average number of UEs with category = 4.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs with category = 4 at sampling time.

Explanation

When eNodeB receives the UECapibilityInformation message from UE, it


gets the category of the UE. The number of cat4 user is incremented by
1 When the eNodeB sends the InitialContextSetupResponse message
to MME.
When eNodeB releases the Ue Context triggered by MME or eNodeB,
the number is decremented by 1.

Updated

The counter is updated by accumulating all the sample UEs with category
= 4, and then dividing the sum by the measurement period.

10.4.3.3.5 C373384347 Cat5 Average User Number


Definition

The counter is used to count average number of UEs with category = 5.

Sampling Interval

10 s

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collects the number of UEs with category = 5 at sampling time.

Explanation

When eNodeB receives the UECapibilityInformation message from UE, it


gets the category of the UE. The number of cat5 user is incremented by
1 When the eNodeB sends the InitialContextSetupResponse message
to MME.
When eNodeB releases the Ue Context triggered by MME or eNodeB,
the number is decremented by 1.

10-185
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample UEs with category
= 5, and then dividing the sum by the measurement period.

10.5 RLC PDU Number on Cell


10.5.1 RLC PDU Retransmission
10.5.1.1 Flow Charts and Sampling Points
No chart.

10.5.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373454816

Number of RLC PDU Retransmission

C373454817

Number of RLC PDU Transmission

10.5.1.3 Counter Description


10.5.1.3.1 C373454816 Number of RLC PDU Retransmission
Definition

The counter is used to count the number of RLC PDU re-transmitted by


eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the RLC layer retransmit a RLC PDU to MAC layer.

Explanation

The counter provides the number of RLC PDUs retransmited by eNodeB.

Updated

The counter is incremented by 1 when the RLC layer retransmit a RLC


PDU to MAC layer.

10.5.1.3.2 C373454817 Number of RLC PDU Transmission


Definition

The counter is used to count the number of RLC PDU transmitted by


eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative
10-186

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Unit

Times

Measurement Object

Cell

Sampling Point

When the RLC layer transmit a RLC PDU to MAC layer.

Explanation

The counter provides the number of RLC PDUs transmited by eNodeB.

Updated

The counter is incremented by 1 when the RLC layer transmit a RLC


PDU to MAC layer.

10.6 Traffic Throughput on Cell(PLMN)


10.6.1 PDCP SDU Bitrate
10.6.1.1 Flow Charts and Sampling Points
No chart.

10.6.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C374574200

Average Bitrate of PDCP SDU in The UL in Control Plane

C374574201

Maximum Bitrate of PDCP SDU in The UL in Control Plane

C374574202

Average Bitrate of PDCP SDU in The DL in Control Plane

C374574203

Maximum Bitrate of PDCP SDU in The DL in Control Plane

C374574204

Average Bitrate of PDCP SDU in The UL (QCI=1)

C374574205

Average Bitrate of PDCP SDU in The UL (QCI=2)

C374574206

Average Bitrate of PDCP SDU in The UL (QCI=3)

C374574207

Average Bitrate of PDCP SDU in The UL (QCI=4)

C374574208

Average Bitrate of PDCP SDU in The UL (QCI=5)

10

C374574209

Average Bitrate of PDCP SDU in The UL (QCI=6)

11

C374574210

Average Bitrate of PDCP SDU in The UL (QCI=7)

12

C374574211

Average Bitrate of PDCP SDU in The UL (QCI=8)

13

C374574212

Average Bitrate of PDCP SDU in The UL (QCI=9)

14

C374574213

Average Bitrate of PDCP SDU in The DL (QCI=1)

15

C374574214

Average Bitrate of PDCP SDU in The DL (QCI=2)

16

C374574215

Average Bitrate of PDCP SDU in The DL (QCI=3)

17

C374574216

Average Bitrate of PDCP SDU in The DL (QCI=4)


10-187

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
18

C374574217

Average Bitrate of PDCP SDU in The DL (QCI=5)

19

C374574218

Average Bitrate of PDCP SDU in The DL (QCI=6)

20

C374574219

Average Bitrate of PDCP SDU in The DL (QCI=7)

21

C374574220

Average Bitrate of PDCP SDU in The DL (QCI=8)

22

C374574221

Average Bitrate of PDCP SDU in The DL (QCI=9)

23

C374574222

Maximum Bitrate of PDCP SDU in The UL (QCI=1)

24

C374574223

Maximum Bitrate of PDCP SDU in The UL (QCI=2)

25

C374574224

Maximum Bitrate of PDCP SDU in The UL (QCI=3)

26

C374574225

Maximum Bitrate of PDCP SDU in The UL (QCI=4)

27

C374574226

Maximum Bitrate of PDCP SDU in The UL (QCI=5)

28

C374574227

Maximum Bitrate of PDCP SDU in The UL (QCI=6)

29

C374574228

Maximum Bitrate of PDCP SDU in The UL (QCI=7)

30

C374574229

Maximum Bitrate of PDCP SDU in The UL (QCI=8)

31

C374574230

Maximum Bitrate of PDCP SDU in The UL (QCI=9)

32

C374574231

Maximum Bitrate of PDCP SDU in The DL (QCI=1)

33

C374574232

Maximum Bitrate of PDCP SDU in The DL (QCI=2)

34

C374574233

Maximum Bitrate of PDCP SDU in The DL (QCI=3)

35

C374574234

Maximum Bitrate of PDCP SDU in The DL (QCI=4)

36

C374574235

Maximum Bitrate of PDCP SDU in The DL (QCI=5)

37

C374574236

Maximum Bitrate of PDCP SDU in The DL (QCI=6)

38

C374574237

Maximum Bitrate of PDCP SDU in The DL (QCI=7)

39

C374574238

Maximum Bitrate of PDCP SDU in The DL (QCI=8)

40

C374574239

Maximum Bitrate of PDCP SDU in The DL (QCI=9)

41

C374574240

Maximum Bitrate of PDCP SDU in The UL in Traffic Plane

42

C374574241

Maximum Bitrate of PDCP SDU in The DL in Traffic Plane

43

C374574242

Average Bitrate of PDCP SDU in The UL in Traffic Plane

44

C374574243

Average Bitrate of PDCP SDU in The DL in Traffic Plane

10-188
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.1.3 Counter Description


10.6.1.3.1 C374574200 Average Bitrate of PDCP SDU in The UL in Control Plane
Definition

The counter is used to count the average cell bit-rate of control plane
PDCP SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB sends the PDCP SDU of signal radio bear to the MME.

Explanation

At sampling time,the eNodeB collects the UL PDCP SDU volume of SRB


that is sent by PDCP layer from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL SRB PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.2 C374574201 Maximum Bitrate of PDCP SDU in The UL in Control Plane


Definition

The counter is used to count the maximum cell bit-rate of control plane
PDCP SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB sends the PDCP SDU of signal radio bear to the MME.

Explanation

At sampling time,the eNodeB collects the UL PDCP SDU volume of


SRB that is sent by PDCP layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
SDU volume is larger than the prior at sampling point.

10.6.1.3.3 C374574202 Average Bitrate of PDCP SDU in The DL in Control Plane


Definition

The counter is used to count the average cell bit-rate of control plane
PDCP SDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps
10-189

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the PDCP SDU of signal radio bear from the
MME.

Explanation

At sampling time,the eNodeB collects the DL PDCP SDU volume of SRB


that is received by PDCP layer from the previous sampling time to the
current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL SRB PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.4 C374574203 Maximum Bitrate of PDCP SDU in The DL in Control Plane


Definition

The counter is used to count the maximum cell bit-rate of control plane
PDCP SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the PDCP SDU of signal radio bear from the
MME.

Explanation

At sampling time,the eNodeB collects the DL PDCP SDU volume of SRB


that is received by PDCP layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL SRB
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.5 C374574204 Average Bitrate of PDCP SDU in The UL (QCI=1)


Definition

The counter is used to count the average cell bit-rate of QCI1 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 PDCP SDU to the SGW.

10-190
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI1 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.6 C374574205 Average Bitrate of PDCP SDU in The UL (QCI=2)


Definition

The counter is used to count the average cell bit-rate of QCI2 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI2 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.7 C374574206 Average Bitrate of PDCP SDU in The UL (QCI=3)


Definition

The counter is used to count the average cell bit-rate of QCI3 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

10-191
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample UL QCI3 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.8 C374574207 Average Bitrate of PDCP SDU in The UL (QCI=4)


Definition

The counter is used to count the average cell bit-rate of QCI4 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI4 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.9 C374574208 Average Bitrate of PDCP SDU in The UL (QCI=5)


Definition

The counter is used to count the average cell bit-rate of QCI5 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI5 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.10 C374574209 Average Bitrate of PDCP SDU in The UL (QCI=6)


Definition

The counter is used to count the average cell bit-rate of QCI6 PDCP
SDUs on the uplink.
10-192

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI6 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.11 C374574210 Average Bitrate of PDCP SDU in The UL (QCI=7)


Definition

The counter is used to count the average cell bit-rate of QCI7 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI7 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.12 C374574211 Average Bitrate of PDCP SDU in The UL (QCI=8)


Definition

The counter is used to count the average cell bit-rate of QCI8 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 PDCP SDU to the SGW.

10-193
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI8 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.13 C374574212 Average Bitrate of PDCP SDU in The UL (QCI=9)


Definition

The counter is used to count the average cell bit-rate of QCI9 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that is
sent by PDCP layer in UL from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI9 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.14 C374574213 Average Bitrate of PDCP SDU in The DL (QCI=1)


Definition

The counter is used to count the average cell bit-rate of QCI1 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI1 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.
10-194

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is updated by accumulating all the sample DL QCI1 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.15 C374574214 Average Bitrate of PDCP SDU in The DL (QCI=2)


Definition

The counter is used to count the average cell bit-rate of QCI2 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI2 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI2 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.16 C374574215 Average Bitrate of PDCP SDU in The DL (QCI=3)


Definition

The counter is used to count the average cell bit-rate of QCI3 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI3 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI3 PDCP


SDU volume, and then dividing the sum by the measurement period.

10-195
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.6.1.3.17 C374574216 Average Bitrate of PDCP SDU in The DL (QCI=4)


Definition

The counter is used to count the average cell bit-rate of QCI4 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI4 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI4 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.18 C374574217 Average Bitrate of PDCP SDU in The DL (QCI=5)


Definition

The counter is used to count the average cell bit-rate of QCI5 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI5 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI5 PDCP


SDU volume, and then dividing the sum by the measurement period.

10-196
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.1.3.19 C374574218 Average Bitrate of PDCP SDU in The DL (QCI=6)


Definition

The counter is used to count the average cell bit-rate of QCI6 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI6 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI6 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.20 C374574219 Average Bitrate of PDCP SDU in The DL (QCI=7)


Definition

The counter is used to count the average cell bit-rate of QCI7 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI7 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI7 PDCP


SDU volume, and then dividing the sum by the measurement period.

10-197
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.6.1.3.21 C374574220 Average Bitrate of PDCP SDU in The DL (QCI=8)


Definition

The counter is used to count the average cell bit-rate of QCI8 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI8 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI8 PDCP


SDU volume, and then dividing the sum by the measurement period.

10.6.1.3.22 C374574221 Average Bitrate of PDCP SDU in The DL (QCI=9)


Definition

The counter is used to count the average cell bit-rate of QCI9 PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI9 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI9 PDCP


SDU volume, and then dividing the sum by the measurement period.

10-198
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.1.3.23 C374574222 Maximum Bitrate of PDCP SDU in The UL (QCI=1)


Definition

The counter is used to count the maximum cell bit-rate of QCI1 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted.The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.24 C374574223 Maximum Bitrate of PDCP SDU in The UL (QCI=2)


Definition

The counter is used to count the maximum cell bit-rate of QCI2 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.25 C374574224 Maximum Bitrate of PDCP SDU in The UL (QCI=3)


Definition

The counter is used to count the maximum cell bit-rate of QCI3 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

10-199
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.26 C374574225 Maximum Bitrate of PDCP SDU in The UL (QCI=4)


Definition

The counter is used to count the maximum cell bit-rate of QCI4 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.27 C374574226 Maximum Bitrate of PDCP SDU in The UL (QCI=5)


Definition

The counter is used to count the maximum cell bit-rate of QCI5 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 PDCP SDU to the SGW.

10-200
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.28 C374574227 Maximum Bitrate of PDCP SDU in The UL (QCI=6)


Definition

The counter is used to count the maximum cell bit-rate of QCI6 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.29 C374574228 Maximum Bitrate of PDCP SDU in The UL (QCI=7)


Definition

The counter is used to count the maximum cell bit-rate of QCI7 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

10-201
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI7
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.30 C374574229 Maximum Bitrate of PDCP SDU in The UL (QCI=8)


Definition

The counter is used to count the maximum cell bit-rate of QCI8 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.31 C374574230 Maximum Bitrate of PDCP SDU in The UL (QCI=9)


Definition

The counter is used to count the maximum cell bit-rate of QCI9 PDCP
SDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that
is sent by PDCP layer from the previous sampling time to the current
sampling time. PDCP SDUs that are forwarded over the X2/S1 to another
eNodeB during handover have been deducted. The counter provides the
maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.32 C374574231 Maximum Bitrate of PDCP SDU in The DL (QCI=1)


Definition

The counter is used to count the maximum cell bit-rate of QCI1 PDCP
SDUs on the downlink.
10-202

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI1 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI1 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.33 C374574232 Maximum Bitrate of PDCP SDU in The DL (QCI=2)


Definition

The counter is used to count the maximum cell bit-rate of QCI2 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI2 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI2 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.34 C374574233 Maximum Bitrate of PDCP SDU in The DL (QCI=3)


Definition

The counter is used to count the maximum cell bit-rate of QCI3 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell
10-203

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the QCI3 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI3 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.35 C374574234 Maximum Bitrate of PDCP SDU in The DL (QCI=4)


Definition

The counter is used to count the maximum cell bit-rate of QCI4 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI4 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI4 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.36 C374574235 Maximum Bitrate of PDCP SDU in The DL (QCI=5)


Definition

The counter is used to count the maximum cell bit-rate of QCI5 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI5 PDCP SDU from the SGW or the
other eNodeB.

10-204
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time,the eNodeB collects the QCI5 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.37 C374574236 Maximum Bitrate of PDCP SDU in The DL (QCI=6)


Definition

The counter is used to count the maximum cell bit-rate of QCI6 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI6 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI6 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.38 C374574237 Maximum Bitrate of PDCP SDU in The DL (QCI=7)


Definition

The counter is used to count the maximum cell bit-rate of QCI7 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI7 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI7 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.
10-205

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI7
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.39 C374574238 Maximum Bitrate of PDCP SDU in The DL (QCI=8)


Definition

The counter is used to count the maximum cell bit-rate of QCI8 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI8 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI8 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
PDCP SDU volume is larger than the prior at sampling point.

10.6.1.3.40 C374574239 Maximum Bitrate of PDCP SDU in The DL (QCI=9)


Definition

The counter is used to count the maximum cell bit-rate of QCI9 PDCP
SDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the QCI9 PDCP SDU from the SGW or the
other eNodeB.

Explanation

At sampling time,the eNodeB collects the QCI9 PDCP SDU volume that
is received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
PDCP SDU volume is larger than the prior at sampling point.

10-206
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.1.3.41 C374574240 Maximum Bitrate of PDCP SDU in The UL in Traffic Plane


Definition

The counter is used to count the maximum cell bit-rate of PDCP SDUs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is sent
by PDCP layer from the previous sampling time to the current sampling
time. PDCP SDUs that are forwarded over the X2/S1 to another eNodeB
during handover have been deducted. The counter provides the maximum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
SDU volume is larger than the prior at sampling point.

10.6.1.3.42 C374574241 Maximum Bitrate of PDCP SDU in The DL in Traffic Plane


Definition

The counter is used to count the maximum cell bit-rate of PDCP SDUs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the PDCP SDU from the SGW or the other
eNodeB.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is


received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted.The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL PDCP
SDU volume is larger than the prior at sampling point.

10.6.1.3.43 C374574242 Average Bitrate of PDCP SDU in The UL in Traffic Plane


Definition

The counter is used to count the average cell bit-rate of PDCP SDUs on
the uplink.

Sampling Interval

1s

Counter Type

Average
10-207

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the PDCP SDU to the SGW.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is sent
by PDCP layer from the previous sampling time to the current sampling
time. PDCP SDUs that are forwarded over the X2/S1 to another eNodeB
during handover have been deducted. The counter provides the average
value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL PDCP SDU


volume, and then dividing the sum by the measurement period.

10.6.1.3.44 C374574243 Average Bitrate of PDCP SDU in The DL in Traffic Plane


Definition

The counter is used to count the average cell bit-rate of PDCP SDUs on
the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB receives the PDCP SDU from the SGW or the other
eNodeB.

Explanation

At sampling time,the eNodeB collects the PDCP SDU volume that is


received by PDCP layer in DL from the previous sampling time to the
current sampling time. PDCP SDUs that are forwarded over the X2/S1
to another eNodeB during handover have been deducted. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL PDCP SDU


volume, and then dividing the sum by the measurement period.

10.6.2 PDCP PDU Throughput


10.6.2.1 Flow Charts and Sampling Points

10-208
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Figure 10-5 PDCP PDU Throughput

10.6.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C374543600

Maximum Cell DL PDCP Throughput

C374543601

Minimum Cell DL PDCP Throughput

C374543602

Average Cell DL PDCP Throughput

C374543603

Maximum Cell UL PDCP Throughput

C374543604

Minimum Cell UL PDCP Throughput

C374543605

Average Cell UL PDCP Throughput

C374543606

Maximum Cell DL PDCP Throughput(QCI=1)

C374543607

Minimum Cell DL PDCP Throughput(QCI=1)

C374543608

Average Cell DL PDCP Throughput(QCI=1)

10

C374543609

Maximum Cell UL PDCP Throughput(QCI=1)

11

C374543610

Minimum Cell UL PDCP Throughput(QCI=1)

12

C374543611

Average Cell UL PDCP Throughput(QCI=1)

13

C374543612

Maximum Cell DL PDCP Throughput(QCI=2)

14

C374543613

Minimum Cell DL PDCP Throughput(QCI=2)

15

C374543614

Average Cell DL PDCP Throughput(QCI=2)

10-209
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
16

C374543615

Maximum Cell UL PDCP Throughput(QCI=2)

17

C374543616

Minimum Cell UL PDCP Throughput(QCI=2)

18

C374543617

Average Cell UL PDCP Throughput(QCI=2)

19

C374543618

Maximum Cell DL PDCP Throughput(QCI=3)

20

C374543619

Minimum Cell DL PDCP Throughput(QCI=3)

21

C374543620

Average Cell DL PDCP Throughput(QCI=3)

22

C374543621

Maximum Cell UL PDCP Throughput(QCI=3)

23

C374543622

Minimum Cell UL PDCP Throughput(QCI=3)

24

C374543623

Average Cell UL PDCP Throughput(QCI=3)

25

C374543624

Maximum Cell DL PDCP Throughput(QCI=4)

26

C374543625

Minimum Cell DL PDCP Throughput(QCI=4)

27

C374543626

Average Cell DL PDCP Throughput(QCI=4)

28

C374543627

Maximum Cell UL PDCP Throughput(QCI=4)

29

C374543628

Minimum Cell UL PDCP Throughput(QCI=4)

30

C374543629

Average Cell UL PDCP Throughput(QCI=4)

31

C374543630

Maximum Cell DL PDCP Throughput(QCI=5)

32

C374543631

Minimum Cell DL PDCP Throughput(QCI=5)

33

C374543632

Average Cell DL PDCP Throughput(QCI=5)

34

C374543633

Maximum Cell UL PDCP Throughput(QCI=5)

35

C374543634

Minimum Cell UL PDCP Throughput(QCI=5)

36

C374543635

Average Cell UL PDCP Throughput(QCI=5)

37

C374543636

Maximum Cell DL PDCP Throughput(QCI=6)

38

C374543637

Minimum Cell DL PDCP Throughput(QCI=6)

39

C374543638

Average Cell DL PDCP Throughput(QCI=6)

40

C374543639

Maximum Cell UL PDCP Throughput(QCI=6)

41

C374543640

Minimum Cell UL PDCP Throughput(QCI=6)

42

C374543641

Average Cell UL PDCP Throughput(QCI=6)

43

C374543642

Maximum Cell DL PDCP Throughput(QCI=7)

44

C374543643

Minimum Cell DL PDCP Throughput(QCI=7)

45

C374543644

Average Cell DL PDCP Throughput(QCI=7)

46

C374543645

Maximum Cell UL PDCP Throughput(QCI=7)

47

C374543646

Minimum Cell UL PDCP Throughput(QCI=7)

10-210
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
48

C374543647

Average Cell UL PDCP Throughput(QCI=7)

49

C374543648

Maximum Cell DL PDCP Throughput(QCI=8)

50

C374543649

Minimum Cell DL PDCP Throughput(QCI=8)

51

C374543650

Average Cell DL PDCP Throughput(QCI=8)

52

C374543651

Maximum Cell UL PDCP Throughput(QCI=8)

53

C374543652

Minimum Cell UL PDCP Throughput(QCI=8)

54

C374543653

Average Cell UL PDCP Throughput(QCI=8)

55

C374543654

Maximum Cell DL PDCP Throughput(QCI=9)

56

C374543655

Minimum Cell DL PDCP Throughput(QCI=9)

57

C374543656

Average Cell DL PDCP Throughput(QCI=9)

58

C374543657

Maximum Cell UL PDCP Throughput(QCI=9)

59

C374543658

Minimum Cell UL PDCP Throughput(QCI=9)

60

C374543659

Average Cell UL PDCP Throughput(QCI=9)

10.6.2.3 Counter Description


10.6.2.3.1 C374543600 Maximum Cell DL PDCP Throughput
Definition

The counter is used to count the maximum cell throughput of PDCP PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the PDU to the eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is sent by PDCP layer to RLC layer from the
previous sampling time to the current sampling time. The counter provides
the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL PDCP
PDU volume is larger than the prior at sampling point.

10.6.2.3.2 C374543601 Minimum Cell DL PDCP Throughput


Definition

The counter is used to count the minimum cell throughput of PDCP PDUs
on the downlink.
10-211

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the PDU to the eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is sent by PDCP layer to RLC layer from the
previous sampling time to the current sampling time. The counter provides
the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL PDCP
PDU volume is smaller than the prior at sampling point.

10.6.2.3.3 C374543602 Average Cell DL PDCP Throughput


Definition

The counter is used to count the average cell throughput of PDCP PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the PDU to the eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is sent by PDCP layer to RLC layer from the
previous sampling time to the current sampling time. The counter provides
the average value of all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL PDCP PDU


volume, and then dividing the sum by the measurement period.

10.6.2.3.4 C374543603 Maximum Cell UL PDCP Throughput


Definition

The counter is used to count the maximum cell throughput of PDCP PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the PDU from the eNodeB RLC
layer.

10-212
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that
includes the DRB's and SRB's and is received by PDCP layer from RLC
layer from the previous sampling time to the current sampling time. The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
PDU volume is larger than the prior at sampling point.

10.6.2.3.5 C374543604 Minimum Cell UL PDCP Throughput


Definition

The counter is used to count the minimum cell throughput of PDCP PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the PDU from the eNodeB RLC
layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that
includes the DRB's and SRB's and is received by PDCP layer from RLC
layer from the previous sampling time to the current sampling time. The
counter provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL PDCP
PDU volume is smaller than the prior at sampling point.

10.6.2.3.6 C374543605 Average Cell UL PDCP Throughput


Definition

The counter is used to count the average cell throughput of PDCP PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the PDU from the eNodeB RLC
layer.

Explanation

At sampling time, the eNodeB collects the PDCP PDU volume that includes
the DRB's and SRB's and is received by PDCP layer from RLC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

10-213
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample UL PDCP PDU


volume, and then dividing the sum by the measurement period.

10.6.2.3.7 C374543606 Maximum Cell DL PDCP Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.8 C374543607 Minimum Cell DL PDCP Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.9 C374543608 Average Cell DL PDCP Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 PDCP
PDUs on the downlink.
10-214

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI1 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.10 C374543609 Maximum Cell UL PDCP Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.11 C374543610 Minimum Cell UL PDCP Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

10-215
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer receives the QCI1 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.12 C374543611 Average Cell UL PDCP Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI1 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.13 C374543612 Maximum Cell DL PDCP Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

10-216
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI2
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.14 C374543613 Minimum Cell DL PDCP Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.15 C374543614 Average Cell DL PDCP Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI2 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.16 C374543615 Maximum Cell UL PDCP Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 PDCP
PDUs on the uplink.
10-217

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.17 C374543616 Minimum Cell UL PDCP Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.18 C374543617 Average Cell UL PDCP Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

10-218
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer receives the QCI2 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI2 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.19 C374543618 Maximum Cell DL PDCP Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.20 C374543619 Minimum Cell DL PDCP Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

10-219
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI3
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.21 C374543620 Average Cell DL PDCP Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI3 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.22 C374543621 Maximum Cell UL PDCP Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.23 C374543622 Minimum Cell UL PDCP Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 PDCP
PDUs on the uplink.
10-220

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.24 C374543623 Average Cell UL PDCP Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI3 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.25 C374543624 Maximum Cell DL PDCP Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

10-221
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer sends the QCI4 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.26 C374543625 Minimum Cell DL PDCP Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.27 C374543626 Average Cell DL PDCP Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

10-222
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is updated by accumulating all the sample DL QCI4 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.28 C374543627 Maximum Cell UL PDCP Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.29 C374543628 Minimum Cell UL PDCP Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.30 C374543629 Average Cell UL PDCP Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 PDCP
PDUs on the uplink.
10-223

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI4 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.31 C374543630 Maximum Cell DL PDCP Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.32 C374543631 Minimum Cell DL PDCP Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

10-224
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer sends the QCI5 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.33 C374543632 Average Cell DL PDCP Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI5 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.34 C374543633 Maximum Cell UL PDCP Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

10-225
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI5
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.35 C374543634 Minimum Cell UL PDCP Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.36 C374543635 Average Cell UL PDCP Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI5 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.37 C374543636 Maximum Cell DL PDCP Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 PDCP
PDUs on the downlink.
10-226

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.38 C374543637 Minimum Cell DL PDCP Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.39 C374543638 Average Cell DL PDCP Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

10-227
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer sends the QCI6 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI6 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.40 C374543639 Maximum Cell UL PDCP Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.41 C374543640 Minimum Cell UL PDCP Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

10-228
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI6
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.42 C374543641 Average Cell UL PDCP Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI6 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.43 C374543642 Maximum Cell DL PDCP Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.44 C374543643 Minimum Cell DL PDCP Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 PDCP
PDUs on the downlink.
10-229

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.45 C374543644 Average Cell DL PDCP Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI7 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.46 C374543645 Maximum Cell UL PDCP Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

10-230
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer receives the QCI7 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.47 C374543646 Minimum Cell UL PDCP Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI7 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.48 C374543647 Average Cell UL PDCP Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI7 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

10-231
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample UL QCI7 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.49 C374543648 Maximum Cell DL PDCP Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.50 C374543649 Minimum Cell DL PDCP Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.51 C374543650 Average Cell DL PDCP Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 PDCP
PDUs on the downlink.
10-232

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI8 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.52 C374543651 Maximum Cell UL PDCP Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.53 C374543652 Minimum Cell UL PDCP Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

10-233
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB PDCP layer receives the QCI8 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.54 C374543653 Average Cell UL PDCP Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI8 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.55 C374543654 Maximum Cell DL PDCP Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the maximum value in the
measurement period.

10-234
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current DL QCI9
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.56 C374543655 Minimum Cell DL PDCP Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
sent by PDCP layer to RLC layer from the previous sampling time to the
current sampling time. The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.57 C374543656 Average Cell DL PDCP Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 PDCP
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 DRB PDU to the eNodeB
RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that
is sent by PDCP layer to RLC layer from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI9 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.2.3.58 C374543657 Maximum Cell UL PDCP Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 PDCP
PDUs on the uplink.
10-235

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
PDCP PDU volume is larger than the prior at sampling point.

10.6.2.3.59 C374543658 Minimum Cell UL PDCP Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that
is received by PDCP layer from RLC layer from the previous sampling
time to the current sampling time. The counter provides the minimum
value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
PDCP PDU volume is smaller than the prior at sampling point.

10.6.2.3.60 C374543659 Average Cell UL PDCP Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 PDCP
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

10-236
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB PDCP layer receives the QCI9 DRB PDU from the
eNodeB RLC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 PDCP PDU volume that is
received by PDCP layer from RLC layer from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI9 PDCP


PDU volume, and then dividing the sum by the measurement period.

10.6.3 RLC PDU Throughput


10.6.3.1 Flow Charts and Sampling Points
Figure 10-6 RLC PDU Throughput

10.6.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C374543660

Maximum Cell DL RLC Throughput

C374543661

Minimum Cell DL RLC Throughput

C374543662

Average Cell DL RLC Throughput

C374543663

Maximum Cell UL RLC Throughput


10-237

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
5

C374543664

Minimum Cell UL RLC Throughput

C374543665

Average Cell UL RLC Throughput

C374543666

Maximum Cell DL RLC Throughput(QCI=1)

C374543667

Minimum Cell DL RLC Throughput(QCI=1)

C374543668

Average Cell DL RLC Throughput(QCI=1)

10

C374543669

Maximum Cell UL RLC Throughput(QCI=1)

11

C374543670

Minimum Cell UL RLC Throughput(QCI=1)

12

C374543671

Average Cell UL RLC Throughput(QCI=1)

13

C374543672

Maximum Cell DL RLC Throughput(QCI=2)

14

C374543673

Minimum Cell DL RLC Throughput(QCI=2)

15

C374543674

Average Cell DL RLC Throughput(QCI=2)

16

C374543675

Maximum Cell UL RLC Throughput(QCI=2)

17

C374543676

Minimum Cell UL RLC Throughput(QCI=2)

18

C374543677

Average Cell UL RLC Throughput(QCI=2)

19

C374543678

Maximum Cell DL RLC Throughput(QCI=3)

20

C374543679

Minimum Cell DL RLC Throughput(QCI=3)

21

C374543680

Average Cell DL RLC Throughput(QCI=3)

22

C374543681

Maximum Cell UL RLC Throughput(QCI=3)

23

C374543682

Minimum Cell UL RLC Throughput(QCI=3)

24

C374543683

Average Cell UL RLC Throughput(QCI=3)

25

C374543684

Maximum Cell DL RLC Throughput(QCI=4)

26

C374543685

Minimum Cell DL RLC Throughput(QCI=4)

27

C374543686

Average Cell DL RLC Throughput(QCI=4)

28

C374543687

Maximum Cell UL RLC Throughput(QCI=4)

29

C374543688

Minimum Cell UL RLC Throughput(QCI=4)

30

C374543689

Average Cell UL RLC Throughput(QCI=4)

31

C374543690

Maximum Cell DL RLC Throughput(QCI=5)

32

C374543691

Minimum Cell DL RLC Throughput(QCI=5)

33

C374543692

Average Cell DL RLC Throughput(QCI=5)

34

C374543693

Maximum Cell UL RLC Throughput(QCI=5)

35

C374543694

Minimum Cell UL RLC Throughput(QCI=5)

36

C374543695

Average Cell UL RLC Throughput(QCI=5)

10-238
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
37

C374543696

Maximum Cell DL RLC Throughput(QCI=6)

38

C374543697

Minimum Cell DL RLC Throughput(QCI=6)

39

C374543698

Average Cell DL RLC Throughput(QCI=6)

40

C374543699

Maximum Cell UL RLC Throughput(QCI=6)

41

C374543700

Minimum Cell UL RLC Throughput(QCI=6)

42

C374543701

Average Cell UL RLC Throughput(QCI=6)

43

C374543702

Maximum Cell DL RLC Throughput(QCI=7)

44

C374543703

Minimum Cell DL RLC Throughput(QCI=7)

45

C374543704

Average Cell DL RLC Throughput(QCI=7)

46

C374543705

Maximum Cell UL RLC Throughput(QCI=7)

47

C374543706

Minimum Cell UL RLC Throughput(QCI=7)

48

C374543707

Average Cell UL RLC Throughput(QCI=7)

49

C374543708

Maximum Cell DL RLC Throughput(QCI=8)

50

C374543709

Minimum Cell DL RLC Throughput(QCI=8)

51

C374543710

Average Cell DL RLC Throughput(QCI=8)

52

C374543711

Maximum Cell UL RLC Throughput(QCI=8)

53

C374543712

Minimum Cell UL RLC Throughput(QCI=8)

54

C374543713

Average Cell UL RLC Throughput(QCI=8)

55

C374543714

Maximum Cell DL RLC Throughput(QCI=9)

56

C374543715

Minimum Cell DL RLC Throughput(QCI=9)

57

C374543716

Average Cell DL RLC Throughput(QCI=9)

58

C374543717

Maximum Cell UL RLC Throughput(QCI=9)

59

C374543718

Minimum Cell UL RLC Throughput(QCI=9)

60

C374543719

Average Cell UL RLC Throughput(QCI=9)

10.6.3.3 Counter Description


10.6.3.3.1 C374543660 Maximum Cell DL RLC Throughput
Definition

The counter is used to count the maximum cell throughput of RLC PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

10-239
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the PDU to the eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is sent by RLC layer to MAC layer from the
previous sampling time to the current sampling time.The volume includes
retransmission's PDU. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL RLC
PDU volume is larger than the prior at sampling point.

10.6.3.3.2 C374543661 Minimum Cell DL RLC Throughput


Definition

The counter is used to count the minimum cell throughput of RLC PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the PDU to the eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is sent by RLC layer to MAC layer from the
previous sampling time to the current sampling time.The volume includes
retransmission's PDU.The counter provides the minimum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL RLC
PDU volume is smaller than the prior at sampling point.

10.6.3.3.3 C374543662 Average Cell DL RLC Throughput


Definition

The counter is used to count the average cell throughput of RLC PDUs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the PDU to the eNodeB MAC layer.

10-240
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is sent by RLC layer to MAC layer from the
previous sampling time to the current sampling time.The volume includes
retransmission's PDU. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL RLC PDU


volume, and then dividing the sum by the measurement period.

10.6.3.3.4 C374543663 Maximum Cell UL RLC Throughput


Definition

The counter is used to count the maximum cell throughput of RLC PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the PDU from the eNodeB MAC
layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is received by RLC layer from MAC layer from the
previous sampling time to the current sampling time. The volume includes
retransmission's PDU. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL RLC
PDU volume is larger than the prior at sampling point.

10.6.3.3.5 C374543664 Minimum Cell UL RLC Throughput


Definition

The counter is used to count the minimum cell throughput of RLC PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the PDU from the eNodeB MAC
layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is received by RLC layer from MAC layer from the
previous sampling time to the current sampling time. The volume includes
retransmission's PDU. The counter provides the minimum value in the
measurement period.
10-241

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL RLC
PDU volume is smaller than the prior at sampling point.

10.6.3.3.6 C374543665 Average Cell UL RLC Throughput


Definition

The counter is used to count the average cell throughput of RLC PDUs
on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the PDU from the eNodeB MAC
layer.

Explanation

At sampling time, the eNodeB collects the RLC PDU volume that includes
the DRB's, SRB's and is received by RLC layer from MAC layer from
the previous sampling time to the current sampling time. The volume
includes retransmission's PDU. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL RLC PDU


volume, and then dividing the sum by the measurement period.

10.6.3.3.7 C374543666 Maximum Cell DL RLC Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI1 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that is
sent by RLC layer to MAC layer from the previous sampling time to the
current sampling time.The volume includes retransmission's PDU. The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
RLC PDU volume is larger than the prior at sampling point.

10-242
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.3.3.8 C374543667 Minimum Cell DL RLC Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI1 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.9 C374543668 Average Cell DL RLC Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI1 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI1 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.10 C374543669 Maximum Cell UL RLC Throughput(QCI=1)


Definition

The counter is used to count the maximum cell throughput of QCI1 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum
10-243

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI1 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.11 C374543670 Minimum Cell UL RLC Throughput(QCI=1)


Definition

The counter is used to count the minimum cell throughput of QCI1 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI1 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.12 C374543671 Average Cell UL RLC Throughput(QCI=1)


Definition

The counter is used to count the average cell throughput of QCI1 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI1 DRB PDU from the
eNodeB MAC layer.

10-244
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the QCI1 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI1 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.13 C374543672 Maximum Cell DL RLC Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI2 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.14 C374543673 Minimum Cell DL RLC Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI2 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

10-245
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI2
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.15 C374543674 Average Cell DL RLC Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI2 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI2 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.16 C374543675 Maximum Cell UL RLC Throughput(QCI=2)


Definition

The counter is used to count the maximum cell throughput of QCI2 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI2 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
RLC PDU volume is larger than the prior at sampling point.

10-246
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.3.3.17 C374543676 Minimum Cell UL RLC Throughput(QCI=2)


Definition

The counter is used to count the minimum cell throughput of QCI2 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI2 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.18 C374543677 Average Cell UL RLC Throughput(QCI=2)


Definition

The counter is used to count the average cell throughput of QCI2 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI2 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI2 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI2 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.19 C374543678 Maximum Cell DL RLC Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum
10-247

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI3 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.20 C374543679 Minimum Cell DL RLC Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI3 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.21 C374543680 Average Cell DL RLC Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI3 DRB PDU to the eNodeB
MAC layer.

10-248
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI3 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.22 C374543681 Maximum Cell UL RLC Throughput(QCI=3)


Definition

The counter is used to count the maximum cell throughput of QCI3 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI3 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.23 C374543682 Minimum Cell UL RLC Throughput(QCI=3)


Definition

The counter is used to count the minimum cell throughput of QCI3 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI3 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

10-249
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI3
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.24 C374543683 Average Cell UL RLC Throughput(QCI=3)


Definition

The counter is used to count the average cell throughput of QCI3 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI3 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI3 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI3 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.25 C374543684 Maximum Cell DL RLC Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI4 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
RLC PDU volume is larger than the prior at sampling point.

10-250
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.3.3.26 C374543685 Minimum Cell DL RLC Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI4 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.27 C374543686 Average Cell DL RLC Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI4 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI4 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.28 C374543687 Maximum Cell UL RLC Throughput(QCI=4)


Definition

The counter is used to count the maximum cell throughput of QCI4 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum
10-251

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI4 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.29 C374543688 Minimum Cell UL RLC Throughput(QCI=4)


Definition

The counter is used to count the minimum cell throughput of QCI4 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI4 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI4
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.30 C374543689 Average Cell UL RLC Throughput(QCI=4)


Definition

The counter is used to count the average cell throughput of QCI4 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI4 DRB PDU from the
eNodeB MAC layer.

10-252
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the QCI4 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI4 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.31 C374543690 Maximum Cell DL RLC Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI5 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.32 C374543691 Minimum Cell DL RLC Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI5 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

10-253
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI5
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.33 C374543692 Average Cell DL RLC Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI5 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI5 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.34 C374543693 Maximum Cell UL RLC Throughput(QCI=5)


Definition

The counter is used to count the maximum cell throughput of QCI5 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI5 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
RLC PDU volume is larger than the prior at sampling point.

10-254
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.3.3.35 C374543694 Minimum Cell UL RLC Throughput(QCI=5)


Definition

The counter is used to count the minimum cell throughput of QCI5 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI5 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.36 C374543695 Average Cell UL RLC Throughput(QCI=5)


Definition

The counter is used to count the average cell throughput of QCI5 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI5 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI5 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI5 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.37 C374543696 Maximum Cell DL RLC Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum
10-255

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI6 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.38 C374543697 Minimum Cell DL RLC Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI6 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI6
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.39 C374543698 Average Cell DL RLC Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI6 DRB PDU to the eNodeB
MAC layer.

10-256
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI6 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.40 C374543699 Maximum Cell UL RLC Throughput(QCI=6)


Definition

The counter is used to count the maximum cell throughput of QCI6 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI6 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.41 C374543700 Minimum Cell UL RLC Throughput(QCI=6)


Definition

The counter is used to count the minimum cell throughput of QCI6 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI6 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

10-257
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI6
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.42 C374543701 Average Cell UL RLC Throughput(QCI=6)


Definition

The counter is used to count the average cell throughput of QCI6 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI6 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI6 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI6 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.43 C374543702 Maximum Cell DL RLC Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI7 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
RLC PDU volume is larger than the prior at sampling point.

10-258
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.3.3.44 C374543703 Minimum Cell DL RLC Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI7 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.45 C374543704 Average Cell DL RLC Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI7 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI7 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.46 C374543705 Maximum Cell UL RLC Throughput(QCI=7)


Definition

The counter is used to count the maximum cell throughput of QCI7 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum
10-259

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI7 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.47 C374543706 Minimum Cell UL RLC Throughput(QCI=7)


Definition

The counter is used to count the minimum cell throughput of QCI7 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI7 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.48 C374543707 Average Cell UL RLC Throughput(QCI=7)


Definition

The counter is used to count the average cell throughput of QCI7 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI7 DRB PDU from the
eNodeB MAC layer.

10-260
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the QCI7 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI7 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.49 C374543708 Maximum Cell DL RLC Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI8 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.50 C374543709 Minimum Cell DL RLC Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI8 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

10-261
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI8
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.51 C374543710 Average Cell DL RLC Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI8 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample DL QCI8 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.52 C374543711 Maximum Cell UL RLC Throughput(QCI=8)


Definition

The counter is used to count the maximum cell throughput of QCI8 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI8 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
RLC PDU volume is larger than the prior at sampling point.

10-262
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.6.3.3.53 C374543712 Minimum Cell UL RLC Throughput(QCI=8)


Definition

The counter is used to count the minimum cell throughput of QCI8 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI8 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.54 C374543713 Average Cell UL RLC Throughput(QCI=8)


Definition

The counter is used to count the average cell throughput of QCI8 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI8 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI8 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI8 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.55 C374543714 Maximum Cell DL RLC Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Maximum
10-263

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI9 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.56 C374543715 Minimum Cell DL RLC Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI9 DRB PDU to the eNodeB
MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.57 C374543716 Average Cell DL RLC Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 RLC
PDUs on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer sends the QCI9 DRB PDU to the eNodeB
MAC layer.

10-264
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is sent by RLC layer to MAC layer from
the previous sampling time to the current sampling time.The volume
includes retransmission's PDU. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI9 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.3.3.58 C374543717 Maximum Cell UL RLC Throughput(QCI=9)


Definition

The counter is used to count the maximum cell throughput of QCI9 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI9 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
RLC PDU volume is larger than the prior at sampling point.

10.6.3.3.59 C374543718 Minimum Cell UL RLC Throughput(QCI=9)


Definition

The counter is used to count the minimum cell throughput of QCI9 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI9 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the minimum value in the measurement period.

10-265
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current UL QCI9
RLC PDU volume is smaller than the prior at sampling point.

10.6.3.3.60 C374543719 Average Cell UL RLC Throughput(QCI=9)


Definition

The counter is used to count the average cell throughput of QCI9 RLC
PDUs on the uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB RLC layer receives the QCI9 DRB PDU from the
eNodeB MAC layer.

Explanation

At sampling time, the eNodeB collects the QCI9 RLC PDU volume that
includes the retransmission's and is received by RLC layer from MAC layer
from the previous sampling time to the current sampling time. The counter
provides the average value of all sampling point in the measurement
period.

Updated

The counter is updated by accumulating all the sample UL QCI9 RLC PDU
volume, and then dividing the sum by the measurement period.

10.6.4 MAC TB Throughput


10.6.4.1 Flow Charts and Sampling Points

10-266
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Figure 10-7 MAC TB Throughput

10.6.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C374543720

Maximum Cell DL MAC Throughput

C374543721

Minimum Cell DL MAC Throughput

C374543722

Average Cell DL MAC Throughput

C374543723

Maximum Cell UL MAC Throughput

C374543724

Minimum Cell UL MAC Throughput

C374543725

Average Cell UL MAC Throughput

10.6.4.3 Counter Description


10.6.4.3.1 C374543720 Maximum Cell DL MAC Throughput
Definition

The counter is used to count the maximum cell throughput of MAC TBs
on the downlink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell
10-267

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB MAC layer sends the transport block to the eNodeB
PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is sent by MAC layer to PHY layer from the previous
sampling time to the current sampling time. The counter provides the
minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current DL MAC
TB volume is larger than the prior at sampling point.

10.6.4.3.2 C374543721 Minimum Cell DL MAC Throughput


Definition

The counter is used to count the minimum cell throughput of MAC TBs
on the downlink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB MAC layer sends the transport block to the eNodeB
PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is sent by MAC layer to PHY layer from the previous
sampling time to the current sampling time. The counter provides the
average value in the measurement period.

Updated

The counter is replaced with the current value when the current DL MAC
TB volume is smaller than the prior at sampling point.

10.6.4.3.3 C374543722 Average Cell DL MAC Throughput


Definition

The counter is used to count the average cell throughput of MAC TBs
on the downlink.

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB MAC layer sends the transport block to the eNodeB
PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is sent by MAC layer to PHY layer from the previous
sampling time to the current sampling time. The counter provides the
maximum value in the measurement period.

10-268
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is updated by accumulating all the sample DL MAC TB


volume, and then dividing the sum by the measurement period.

10.6.4.3.4 C374543723 Maximum Cell UL MAC Throughput


Definition

The counter is used to count the maximum cell throughput of MAC TBs
on the uplink.

Sampling Interval

1s

Counter Type

Maximum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB MAC layer receives the transport block from the
eNodeB PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is received by MAC layer from PHY layer from the
previous sampling time to the current sampling time. The counter provides
the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current UL MAC
TB volume is larger than the prior at sampling point.

10.6.4.3.5 C374543724 Minimum Cell UL MAC Throughput


Definition

The counter is used to count the minimum cell throughput of MAC TBs
on the uplink.

Sampling Interval

1s

Counter Type

Minimum

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB MAC layer receives the transport block from the
eNodeB PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is received by MAC layer from PHY layer from the
previous sampling time to the current sampling time. The counter provides
the average value in the measurement period.

Updated

The counter is replaced with the current value when the current UL MAC
TB volume is smaller than the prior at sampling point.

10.6.4.3.6 C374543725 Average Cell UL MAC Throughput


Definition

The counter is used to count the average cell throughput of MAC TBs
on the uplink.
10-269

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Average

Unit

Mbps

Measurement Object

Logic Cell

Sampling Point

When the eNodeB MAC layer receives the transport block from the
eNodeB PHY layer.

Explanation

At sampling time, the eNodeB collects the MAC TB volume that includes
retransmission's and is received by MAC layer from PHY layer from the
previous sampling time to the current sampling time. The counter provides
the maximum value in the measurement period.

Updated

The counter is updated by accumulating all the sample UL MAC TB


volume, and then dividing the sum by the measurement period.

10.7 Traffic Delay on Cell(PLMN)


10.7.1 IP Latency on Cell
10.7.1.1 Flow Charts and Sampling Points
Figure 10-8 IP Latency

10.7.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C374564109

DL QCI1 IP Packet Delay

C374564110

DL QCI2 IP Packet Delay

C374564111

DL QCI3 IP Packet Delay


10-270

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
4

C374564112

DL QCI4 IP Packet Delay

C374564113

DL QCI5 IP Packet Delay

C374564114

DL QCI6 IP Packet Delay

C374564115

DL QCI7 IP Packet Delay

C374564116

DL QCI8 IP Packet Delay

C374564117

DL QCI9 IP Packet Delay

10

C374564119

DL IP Packet Delay

10.7.1.3 Counter Description


10.7.1.3.1 C374564109 DL QCI1 IP Packet Delay
Definition

The counter is used to count IP Latency of QCI1 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI1 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI1 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI1 PDCP SDU over the air.

10.7.1.3.2 C374564110 DL QCI2 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI2 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

10-271
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

The eNodeB records the start time at receiving the QCI2 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI2 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI2 PDCP SDU over the air.

10.7.1.3.3 C374564111 DL QCI3 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI3 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI3 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI3 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI3 PDCP SDU over the air.

10.7.1.3.4 C374564112 DL QCI4 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI4 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI4 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

10-272
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When a QCI4 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI4 PDCP SDU over the air.

10.7.1.3.5 C374564113 DL QCI5 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI5 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI5 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI5 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI5 PDCP SDU over the air.

10.7.1.3.6 C374564114 DL QCI6 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI6 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI6 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI6 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI6 PDCP SDU over the air.

10-273
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.7.1.3.7 C374564115 DL QCI7 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI7 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI7 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI7 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI7 PDCP SDU over the air.

10.7.1.3.8 C374564116 DL QCI8 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI8 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI8 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI8 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI8 PDCP SDU over the air.

10.7.1.3.9 C374564117 DL QCI9 IP Packet Delay


Definition

The counter is used to count IP Latency of QCI9 packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

10-274
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI9 PDCP SDU,
and than records the end time at sending the first part of the PDCP SDU
over the air.

Explanation

When a QCI9 PDCP SDU arrives the eNodeB PDCP layer, it is the start
point in time.When the first piece of PDCP SDU was was sent to air
interface,it is the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the QCI9 PDCP SDU over the air.

10.7.1.3.10 C374564119 DL IP Packet Delay


Definition

The counter is used to count IP Latency of packets in DL.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the PDCP SDU, and than
records the end time at sending the first part of the PDCP SDU over the air.

Explanation

When a PDCP SDU arrives the eNodeB PDCP layer, it is the start point in
time.When the first piece of PDCP SDU was was sent to air interface,it is
the end point in time.
IP Latency in DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB sends the
first part of the PDCP SDU over the air.

10.7.2 PDCP SDU DL Delay on Cell


10.7.2.1 Flow Charts and Sampling Points
No chart.

10.7.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C374564100

DL QCI1 PDCP SDU Delay

C374564101

DL QCI2 PDCP SDU Delay

C374564102

DL QCI3 PDCP SDU Delay


10-275

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
4

C374564103

DL QCI4 PDCP SDU Delay

C374564104

DL QCI5 PDCP SDU Delay

C374564105

DL QCI6 PDCP SDU Delay

C374564106

DL QCI7 PDCP SDU Delay

C374564107

DL QCI8 PDCP SDU Delay

C374564108

DL QCI9 PDCP SDU Delay

10

C374564118

DL PDCP SDU Delay

10.7.2.3 Counter Description


10.7.2.3.1 C374564100 DL QCI1 PDCP SDU Delay
Definition

The counter is used to count the average QCI1 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI1 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI1 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI1 PDCP SDU.

10.7.2.3.2 C374564101 DL QCI2 PDCP SDU Delay


Definition

The counter is used to count the average QCI2 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

10-276
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI2 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI2 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI2 PDCP SDU.

10.7.2.3.3 C374564102 DL QCI3 PDCP SDU Delay


Definition

The counter is used to count the average QCI3 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI3 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI3 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI3 PDCP SDU.

10.7.2.3.4 C374564103 DL QCI4 PDCP SDU Delay


Definition

The counter is used to count the average QCI4 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

10-277
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

The eNodeB records the start time at receiving the QCI4 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI4 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI4 PDCP SDU.

10.7.2.3.5 C374564104 DL QCI5 PDCP SDU Delay


Definition

The counter is used to count the average QCI5 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI5 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI5 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI5 PDCP SDU.

10.7.2.3.6 C374564105 DL QCI6 PDCP SDU Delay


Definition

The counter is used to count the average QCI6 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI6 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.
10-278

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When a QCI6 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI6 PDCP SDU.

10.7.2.3.7 C374564106 DL QCI7 PDCP SDU Delay


Definition

The counter is used to count the average QCI7 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI7 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI7 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI7 PDCP SDU.

10.7.2.3.8 C374564107 DL QCI8 PDCP SDU Delay


Definition

The counter is used to count the average QCI8 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI8 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

10-279
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When a QCI8 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI8 PDCP SDU.

10.7.2.3.9 C374564108 DL QCI9 PDCP SDU Delay


Definition

The counter is used to count the average QCI9 PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the QCI9 PDCP SDU, and
than records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

Explanation

When a QCI9 PDCP SDU arrives the eNodeB PDCP layer,it is the start
point in time.When the last piece of PDCP SDU was received by the
UE according to received HARQ feedback information,it is the end point
in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the QCI9 PDCP SDU.

10.7.2.3.10 C374564118 DL PDCP SDU Delay


Definition

The counter is used to count the average PDCP SDU delay on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

ms

Measurement Object

Logic Cell

Sampling Point

The eNodeB records the start time at receiving the PDCP SDU, and than
records the end time at getting the all positive HARQ acknowledgment
for the PDCP SDU.

10-280
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When a PDCP SDU arrives the eNodeB PDCP layer,it is the start point in
time.When the last piece of PDCP SDU was received by the UE according
to received HARQ feedback information,it is the end point in time.
Packet Delay in the DL is equal to the inteval from the start to the end.

Updated

The counter is increased by the sample value when the eNodeB gets the
all positive HARQ acknowledgment for the PDCP SDU.

10.8 Loss Packet on Cell(PLMN)


10.8.1 PDCP SDU Loss Packet on Cell
10.8.1.1 Flow Charts and Sampling Points
No chart.

10.8.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C374553900

UL PDCP SDU Loss Number, QCI=1

C374553901

UL PDCP SDU Loss Number, QCI=2

C374553902

UL PDCP SDU Loss Number, QCI=3

C374553903

UL PDCP SDU Loss Number, QCI=4

C374553904

UL PDCP SDU Loss Number, QCI=5

C374553905

UL PDCP SDU Loss Number, QCI=6

C374553906

UL PDCP SDU Loss Number, QCI=7

C374553907

UL PDCP SDU Loss Number, QCI=8

C374553908

UL PDCP SDU Loss Number, QCI=9

10

C374553909

DL PDCP SDU Loss Number, QCI=1

11

C374553910

DL PDCP SDU Loss Number, QCI=2

12

C374553911

DL PDCP SDU Loss Number, QCI=3

13

C374553912

DL PDCP SDU Loss Number, QCI=4

14

C374553913

DL PDCP SDU Loss Number, QCI=5

15

C374553914

DL PDCP SDU Loss Number, QCI=6

16

C374553915

DL PDCP SDU Loss Number, QCI=7

17

C374553916

DL PDCP SDU Loss Number, QCI=8

10-281
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
18

C374553917

DL PDCP SDU Loss Number, QCI=9

19

C374553956

UL PDCP SDU Loss Number

20

C374553957

DL PDCP SDU Loss Number

10.8.1.3 Counter Description


10.8.1.3.1 C374553900 UL PDCP SDU Loss Number, QCI=1
Definition

The counter is used to count the number of QCI1 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI1 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI1 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI1 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.2 C374553901 UL PDCP SDU Loss Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI2 PDCP SDU sequece number
discontinuity in UL.

10-282
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When the eNodeB PDCP layer receives the QCI2 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI2 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.3 C374553902 UL PDCP SDU Loss Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI3 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI3 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI3 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.4 C374553903 UL PDCP SDU Loss Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI4 PDCP SDU sequece number
discontinuity in UL.

10-283
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB PDCP layer receives the QCI4 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI4 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.5 C374553904 UL PDCP SDU Loss Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI5 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI5 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI5 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.6 C374553905 UL PDCP SDU Loss Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI6 PDCP SDU sequece number
discontinuity in UL.

10-284
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

When the eNodeB PDCP layer receives the QCI6 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI6 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.7 C374553906 UL PDCP SDU Loss Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI7 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI7 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI7 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.8 C374553907 UL PDCP SDU Loss Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI8 PDCP SDU sequece number
discontinuity in UL.

10-285
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB PDCP layer receives the QCI8 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI8 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.9 C374553908 UL PDCP SDU Loss Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that are lost
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB detects the QCI9 PDCP SDU sequece number
discontinuity in UL.

Explanation

When the eNodeB PDCP layer receives the QCI9 PDCP PDU from
the RLC layer, compare the received PDU sequence number with the
expected sequence number. If the received is larger than the expected,
it is considered that there is packet loss in UL. The number of the lost
SDU is the difference between the received sequence number and the
expected sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the QCI9 UL PDCP SDU sequece
number discontinuity.

10.8.1.3.10 C374553909 DL PDCP SDU Loss Number, QCI=1


Definition

The counter is used to count the number of QCI1 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI1 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

10-286
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

the eNodeB discards the QCI1 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI1 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.11 C374553910 DL PDCP SDU Loss Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI2 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI2 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI2 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.12 C374553911 DL PDCP SDU Loss Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI3 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI3 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

10-287
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is increased by 1 when the eNodeB discards the QCI3 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.13 C374553912 DL PDCP SDU Loss Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI4 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI4 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI4 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.14 C374553913 DL PDCP SDU Loss Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI5 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI5 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI5 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10-288
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.8.1.3.15 C374553914 DL PDCP SDU Loss Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI6 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI6 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI6 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.16 C374553915 DL PDCP SDU Loss Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI7 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI7 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI7 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.17 C374553916 DL PDCP SDU Loss Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min
10-289

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI8 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI8 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI8 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.18 C374553917 DL PDCP SDU Loss Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that are lost at
Uu transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI9 PDCP SDU in DL, for which at least
a part has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the QCI9 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI9 PDCP
SDU in DL, for which at least a part has been transmitted over the air
but not positively acknowledged.

10.8.1.3.19 C374553956 UL PDCP SDU Loss Number


Definition

The counter is used to count the number of PDCP SDU that are lost on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

10-290
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB detects the PDCP SDU sequece number discontinuity
in UL.

Explanation

When the eNodeB PDCP layer receives the PDCP PDU from the RLC
layer, compare the received PDU sequence number with the expected
sequence number. If the received is larger than the expected, it is
considered that there is packet loss in UL. The number of the lost SDU is
the difference between the received sequence number and the expected
sequence number.

Updated

The counter is increased by the number of missing UL PDCP sequence


numbers when the eNodeB detects the UL PDCP SDU sequece number
discontinuity.

10.8.1.3.20 C374553957 DL PDCP SDU Loss Number


Definition

The counter is used to count the number of packets that are lost at Uu
transmission on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the PDCP SDU in DL, for which at least a part
has been transmitted over the air but not positively acknowledged.

Explanation

the eNodeB discards the PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If at least a part of it has
been transmitted over the air but not positively acknowledged, the counter
is counted.

Updated

The counter is increased by 1 when the eNodeB discards the PDCP SDU
in DL, for which at least a part has been transmitted over the air but not
positively acknowledged.

10.8.2 PDCP SDU Discard Packet on Cell


10.8.2.1 Flow Charts and Sampling Points
No chart.

10.8.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C374553918

DL PDCP SDU Discard Number, QCI=1


10-291

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
2

C374553919

DL PDCP SDU Discard Number, QCI=2

C374553920

DL PDCP SDU Discard Number, QCI=3

C374553921

DL PDCP SDU Discard Number, QCI=4

C374553922

DL PDCP SDU Discard Number, QCI=5

C374553923

DL PDCP SDU Discard Number, QCI=6

C374553924

DL PDCP SDU Discard Number, QCI=7

C374553925

DL PDCP SDU Discard Number, QCI=8

C374553926

DL PDCP SDU Discard Number, QCI=9

10

C374553958

DL PDCP SDU Discard Number

10.8.2.3 Counter Description


10.8.2.3.1 C374553918 DL PDCP SDU Discard Number, QCI=1
Definition

The counter is used to count the number of QCI1 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI1 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI1 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI1 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.2 C374553919 DL PDCP SDU Discard Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell
10-292

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB discards the QCI2 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI2 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI2 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.3 C374553920 DL PDCP SDU Discard Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI3 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI3 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI3 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.4 C374553921 DL PDCP SDU Discard Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI4 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI4 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI4 PDCP
SDU in DL, for which no part has been transmitted over the air.

10-293
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.8.2.3.5 C374553922 DL PDCP SDU Discard Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI5 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI5 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI5 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.6 C374553923 DL PDCP SDU Discard Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI6 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI6 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI6 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.7 C374553924 DL PDCP SDU Discard Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell
10-294

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB discards the QCI7 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI7 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI7 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.8 C374553925 DL PDCP SDU Discard Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI8 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB discards the QCI8 PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the QCI8 PDCP
SDU in DL, for which no part has been transmitted over the air.

10.8.2.3.9 C374553926 DL PDCP SDU Discard Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that are dropped
due to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the QCI9 PDCP SDU in DL, for which no part
has been transmitted over the air.

Explanation

the eNodeB will discard the QCI9 PDCP SDU and no part of which has
been transmitted over the air when "timer discard" timer of detecting the
SDU expires or there is no DL buffer for the SDU. The counter is used
to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB discards the QCI9 PDCP
SDU in DL, for which no part has been transmitted over the air.
10-295

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.8.2.3.10 C374553958 DL PDCP SDU Discard Number


Definition

The counter is used to count the number of packets that are dropped due
to congestion, traffic management etc.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB discards the PDCP SDU in DL, for which no part has
been transmitted over the air.

Explanation

the eNodeB discards the PDCP SDU when timeout of "timer discard"
detecting the SDU or not DL buffer for the SDU. If no part of it has been
transmitted over the air, the counter is counted.

Updated

The counter is increased by 1 when the eNodeB discards the PDCP SDU
in DL, for which no part has been transmitted over the air.

10.8.3 PDCP SDU Total Number on Cell


10.8.3.1 Flow Charts and Sampling Points
No chart.

10.8.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C374553927

UL PDCP SDU Number, QCI=1

C374553928

UL PDCP SDU Number, QCI=2

C374553929

UL PDCP SDU Number, QCI=3

C374553930

UL PDCP SDU Number, QCI=4

C374553931

UL PDCP SDU Number, QCI=5

C374553932

UL PDCP SDU Number, QCI=6

C374553933

UL PDCP SDU Number, QCI=7

C374553934

UL PDCP SDU Number, QCI=8

C374553935

UL PDCP SDU Number, QCI=9

10

C374553936

DL PDCP SDU Number, QCI=1

11

C374553937

DL PDCP SDU Number, QCI=2

12

C374553938

DL PDCP SDU Number, QCI=3


10-296

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

NO.

Counter

Counter Name

Number
13

C374553939

DL PDCP SDU Number, QCI=4

14

C374553940

DL PDCP SDU Number, QCI=5

15

C374553941

DL PDCP SDU Number, QCI=6

16

C374553942

DL PDCP SDU Number, QCI=7

17

C374553943

DL PDCP SDU Number, QCI=8

18

C374553944

DL PDCP SDU Number, QCI=9

19

C374553947

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=1

20

C374553948

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=2

21

C374553949

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=3

22

C374553950

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=4

23

C374553951

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=5

24

C374553952

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=6

25

C374553953

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=7

26

C374553954

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=8

27

C374553955

DL PDCP SDU Number Which HARQ Successfully Responds, QCI=9

28

C374553959

UL PDCP SDU Number

29

C374553960

DL PDCP SDU Number

30

C374553961

DL PDCP SDU Number Which HARQ Successfully Responds

10.8.3.3 Counter Description


10.8.3.3.1 C374553927 UL PDCP SDU Number, QCI=1
Definition

The counter is used to count the number of QCI1 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI1 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI1 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

10-297
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI1 PDCP packet in the uplink.

10.8.3.3.2 C374553928 UL PDCP SDU Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI2 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI2 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI2 PDCP packet in the uplink.

10.8.3.3.3 C374553929 UL PDCP SDU Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI3 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI3 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI3 PDCP packet in the uplink.

10.8.3.3.4 C374553930 UL PDCP SDU Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit
10-298

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI4 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI4 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI4 PDCP packet in the uplink.

10.8.3.3.5 C374553931 UL PDCP SDU Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI5 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI5 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI5 PDCP packet in the uplink.

10.8.3.3.6 C374553932 UL PDCP SDU Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI6 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI6 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI6 PDCP packet in the uplink.

10-299
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.8.3.3.7 C374553933 UL PDCP SDU Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI7 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI7 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI7 PDCP packet in the uplink.

10.8.3.3.8 C374553934 UL PDCP SDU Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI8 PDCP packet in the uplink.

Explanation

After the PDCP layer receives the QCI8 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI8 PDCP packet in the uplink.

10.8.3.3.9 C374553935 UL PDCP SDU Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the QCI9 PDCP packet in the uplink.

10-300
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

After the PDCP layer receives the QCI9 PDCP PDU from RLC layer,the
PDU is disposed successfully and than becomes PDCP SDU. The counter
is used to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
QCI9 PDCP packet in the uplink.

10.8.3.3.10 C374553936 DL PDCP SDU Number, QCI=1


Definition

The counter is used to count the number of QCI1 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI1 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI1 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI1 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.11 C374553937 DL PDCP SDU Number, QCI=2


Definition

The counter is used to count the number of QCI2 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI2 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI2 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI2 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.12 C374553938 DL PDCP SDU Number, QCI=3


Definition

The counter is used to count the number of QCI3 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative
10-301

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI3 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI3 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI3 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.13 C374553939 DL PDCP SDU Number, QCI=4


Definition

The counter is used to count the number of QCI4 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI4 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI4 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI4 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.14 C374553940 DL PDCP SDU Number, QCI=5


Definition

The counter is used to count the number of QCI5 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI5 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI5 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI5 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.15 C374553941 DL PDCP SDU Number, QCI=6


Definition

The counter is used to count the number of QCI6 packets that has entered
PDCP on the downlink.
10-302

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI6 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI6 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI6 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.16 C374553942 DL PDCP SDU Number, QCI=7


Definition

The counter is used to count the number of QCI7 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI7 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI7 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI7 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.17 C374553943 DL PDCP SDU Number, QCI=8


Definition

The counter is used to count the number of QCI8 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI8 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI8 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI8 PDCP SDU from the SGW or the other eNodeB.

10-303
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.8.3.3.18 C374553944 DL PDCP SDU Number, QCI=9


Definition

The counter is used to count the number of QCI9 packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the QCI9 PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the QCI9 PDCP SDU from the
SGW or the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
QCI9 PDCP SDU from the SGW or the other eNodeB.

10.8.3.3.19 C374553947 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=1
Definition

The counter is used to count the number of QCI1 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI1 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI1 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.20 C374553948 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=2
Definition

The counter is used to count the number of QCI2 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell
10-304

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI2 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI2 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.21 C374553949 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=3
Definition

The counter is used to count the number of QCI3 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI3 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI3 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.22 C374553950 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=4
Definition

The counter is used to count the number of QCI4 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI4 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

10-305
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI4 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.23 C374553951 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=5
Definition

The counter is used to count the number of QCI5 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI5 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI5 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.24 C374553952 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=6
Definition

The counter is used to count the number of QCI6 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI6 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI6 PDCP SDU,for which all parts have been
transmitted over the air.

10-306
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.8.3.3.25 C374553953 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=7
Definition

The counter is used to count the number of QCI7 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI7 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI7 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.26 C374553954 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=8
Definition

The counter is used to count the number of QCI8 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI8 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI8 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.27 C374553955 DL PDCP SDU Number Which HARQ Successfully Responds , QCI=9
Definition

The counter is used to count the number of QCI9 PDCP SDUs that the
last piece was received by the UE according to received HARQ feedback
information.

Sampling Interval

15 min

Counter Type

Accumulative
10-307

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about QCI9 PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about QCI9 PDCP SDU,for which all parts have been
transmitted over the air.

10.8.3.3.28 C374553959 UL PDCP SDU Number


Definition

The counter is used to count the number of packets that has entered
PDCP on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer sends the PDCP packet in the uplink.

Explanation

After the PDCP layer receives the PDCP PDU from RLC layer,the PDU is
disposed successfully and than becomes PDCP SDU. The counter is used
to count the number of the SDU.

Updated

The counter is increased by 1 when the eNodeB PDCP layer sends the
PDCP packet in the uplink.

10.8.3.3.29 C374553960 DL PDCP SDU Number


Definition

The counter is used to count the number of packets that has entered
PDCP on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB PDCP layer receives the PDCP SDU.

Explanation

When the eNodeB PDCP layer receives the PDCP SDU from the SGW or
the other eNodeB.the counter is used to count.

Updated

The counter is increased by 1 when the eNodeB PDCP layer receives the
PDCP SDU from the SGW or the other eNodeB.

10-308
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.8.3.3.30 C374553961 DL PDCP SDU Number Which HARQ Successfully Responds


Definition

The counter is used to count the number of PDCP SDUs that the last piece
was received by the UE according to received HARQ feedback information.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When the eNodeB got the all positive acknowledgment about PDCP
SDU,for which all parts have been transmitted over the air.

Explanation

The counter provides the number of PDCP SDU when the last piece was
received by the UE according to received HARQ feedback information.

Updated

The counter is increased by 1 when the eNodeB got the all positive
acknowledgment about PDCP SDU,for which all parts have been
transmitted over the air.

10.9 User Number on Cell(PLMN)


10.9.1 Active User Number on Cell
10.9.1.1 Flow Charts and Sampling Points
No chart.

10.9.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C374584300

Average UL Active User Number(QCI=1)

C374584301

Average UL Active User Number(QCI=2)

C374584302

Average UL Active User Number(QCI=3)

C374584303

Average UL Active User Number(QCI=4)

C374584304

Average UL Active User Number(QCI=5)

C374584305

Average UL Active User Number(QCI=6)

C374584306

Average UL Active User Number(QCI=7)

C374584307

Average UL Active User Number(QCI=8)

C374584308

Average UL Active User Number(QCI=9)

10

C374584309

Average DL Active User Number(QCI=1)


10-309

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
11

C374584310

Average DL Active User Number(QCI=2)

12

C374584311

Average DL Active User Number(QCI=3)

13

C374584312

Average DL Active User Number(QCI=4)

14

C374584313

Average DL Active User Number(QCI=5)

15

C374584314

Average DL Active User Number(QCI=6)

16

C374584315

Average DL Active User Number(QCI=7)

17

C374584316

Average DL Active User Number(QCI=8)

18

C374584317

Average DL Active User Number(QCI=9)

19

C374584318

Maximum UL Active User Number(QCI=1)

20

C374584319

Maximum UL Active User Number(QCI=2)

21

C374584320

Maximum UL Active User Number(QCI=3)

22

C374584321

Maximum UL Active User Number(QCI=4)

23

C374584322

Maximum UL Active User Number(QCI=5)

24

C374584323

Maximum UL Active User Number(QCI=6)

25

C374584324

Maximum UL Active User Number(QCI=7)

26

C374584325

Maximum UL Active User Number(QCI=8)

27

C374584326

Maximum UL Active User Number(QCI=9)

28

C374584327

Maximum DL Active User Number(QCI=1)

29

C374584328

Maximum DL Active User Number(QCI=2)

30

C374584329

Maximum DL Active User Number(QCI=3)

31

C374584330

Maximum DL Active User Number(QCI=4)

32

C374584331

Maximum DL Active User Number(QCI=5)

33

C374584332

Maximum DL Active User Number(QCI=6)

34

C374584333

Maximum DL Active User Number(QCI=7)

35

C374584334

Maximum DL Active User Number(QCI=8)

36

C374584335

Maximum DL Active User Number(QCI=9)

37

C374584348

Maximum Active User Number on User Plane

38

C374584349

Average Active User Number on User Plane

10-310
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.9.1.3 Counter Description


10.9.1.3.1 C374584300 Average UL Active User Number(QCI=1)
Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 1,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 1
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI1 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.2 C374584301 Average UL Active User Number(QCI=2)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 2,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 2
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI2 active


UEs, and then dividing the sum by the measurement period.

10-311
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.9.1.3.3 C374584302 Average UL Active User Number(QCI=3)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 3,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 3
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI3 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.4 C374584303 Average UL Active User Number(QCI=4)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 4,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 4
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI4 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.5 C374584304 Average UL Active User Number(QCI=5)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 5,and that have DTCH data queued on
the uplink.
10-312

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 5
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI5 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.6 C374584305 Average UL Active User Number(QCI=6)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 6,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 6
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI6 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.7 C374584306 Average UL Active User Number(QCI=7)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 7,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell
10-313

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 7
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI7 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.8 C374584307 Average UL Active User Number(QCI=8)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 8,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 8
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI8 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.9 C374584308 Average UL Active User Number(QCI=9)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 9,and that have DTCH data queued on
the uplink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI9 DRB at sampling time.

10-314
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 9
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample UL QCI9 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.10 C374584309 Average DL Active User Number(QCI=1)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 1,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 1
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI1 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.11 C374584310 Average DL Active User Number(QCI=2)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 2,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 2
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

10-315
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample DL QCI2 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.12 C374584311 Average DL Active User Number(QCI=3)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 3,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 3
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI3 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.13 C374584312 Average DL Active User Number(QCI=4)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 4,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 4
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI4 active


UEs, and then dividing the sum by the measurement period.

10-316
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.9.1.3.14 C374584313 Average DL Active User Number(QCI=5)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 5,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 5
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI5 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.15 C374584314 Average DL Active User Number(QCI=6)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 6,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 6
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI6 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.16 C374584315 Average DL Active User Number(QCI=7)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 7,and that have DTCH data queued on
the downlink.
10-317

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 7
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI7 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.17 C374584316 Average DL Active User Number(QCI=8)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 8,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 8
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI8 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.18 C374584317 Average DL Active User Number(QCI=9)


Definition

The counter is used to count the average number of UEs for a Data Radio
Bearer of traffic class with QCI = 9,and that have DTCH data queued on
the downlink.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell
10-318

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC or
PDCP protocol layers for a Data Radio Bearer of traffic class with QCI = 9
at sampling time.The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample DL QCI9 active


UEs, and then dividing the sum by the measurement period.

10.9.1.3.19 C374584318 Maximum UL Active User Number(QCI=1)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 1,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 1 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI1
actives UEs is larger than the prior at sampling point.

10.9.1.3.20 C374584319 Maximum UL Active User Number(QCI=2)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 2,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI2 DRB at sampling time.

10-319
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 2 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI2
actives UEs is larger than the prior at sampling point.

10.9.1.3.21 C374584320 Maximum UL Active User Number(QCI=3)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 3,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 3 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI3
actives UEs is larger than the prior at sampling point.

10.9.1.3.22 C374584321 Maximum UL Active User Number(QCI=4)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 4,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI4 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 4 at sampling time.The counter provides the maximum value in the
measurement period.

10-320
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Updated

The counter is replaced with the current value when the current UL QCI4
actives UEs is larger than the prior at sampling point.

10.9.1.3.23 C374584322 Maximum UL Active User Number(QCI=5)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 5,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 5 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI5
actives UEs is larger than the prior at sampling point.

10.9.1.3.24 C374584323 Maximum UL Active User Number(QCI=6)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 6,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 6 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI6
actives UEs is larger than the prior at sampling point.

10-321
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

10.9.1.3.25 C374584324 Maximum UL Active User Number(QCI=7)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 7,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 7 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI7
actives UEs is larger than the prior at sampling point.

10.9.1.3.26 C374584325 Maximum UL Active User Number(QCI=8)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 8,and that have DTCH data
queued on the uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 8 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI8
actives UEs is larger than the prior at sampling point.

10.9.1.3.27 C374584326 Maximum UL Active User Number(QCI=9)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 9,and that have DTCH data
queued on the uplink.
10-322

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in UL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the UL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 9 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current UL QCI9
actives UEs is larger than the prior at sampling point.

10.9.1.3.28 C374584327 Maximum DL Active User Number(QCI=1)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 1,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI1 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 1 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI1
actives UEs is larger than the prior at sampling point.

10.9.1.3.29 C374584328 Maximum DL Active User Number(QCI=2)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 2,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell
10-323

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI2 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 2 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI2
actives UEs is larger than the prior at sampling point.

10.9.1.3.30 C374584329 Maximum DL Active User Number(QCI=3)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 3,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI3 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 3 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI3
actives UEs is larger than the prior at sampling point.

10.9.1.3.31 C374584330 Maximum DL Active User Number(QCI=4)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 4,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI4 DRB at sampling time.

10-324
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 4 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI4
actives UEs is larger than the prior at sampling point.

10.9.1.3.32 C374584331 Maximum DL Active User Number(QCI=5)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 5,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI5 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 5 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI5
actives UEs is larger than the prior at sampling point.

10.9.1.3.33 C374584332 Maximum DL Active User Number(QCI=6)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 6,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI6 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 6 at sampling time.The counter provides the maximum value in the
measurement period.

10-325
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced with the current value when the current DL QCI6
actives UEs is larger than the prior at sampling point.

10.9.1.3.34 C374584333 Maximum DL Active User Number(QCI=7)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 7,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI7 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 7 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI7
actives UEs is larger than the prior at sampling point.

10.9.1.3.35 C374584334 Maximum DL Active User Number(QCI=8)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 8,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI8 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 8 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI8
actives UEs is larger than the prior at sampling point.

10-326
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

10.9.1.3.36 C374584335 Maximum DL Active User Number(QCI=9)


Definition

The counter is used to count the maximum number of UEs for a Data
Radio Bearer of traffic class with QCI = 9,and that have DTCH data queued
on the downlink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in DL buffer for
QCI9 DRB at sampling time.

Explanation

Number of UEs for which there is buffered data for the DL in MAC, RLC
or PDCP protocol layers for a Data Radio Bearer of traffic class with QCI
= 9 at sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current DL QCI9
actives UEs is larger than the prior at sampling point.

10.9.1.3.37 C374584348 Maximum Active User Number on User Plane


Definition

The counter is used to count the maximum number of UEs that have
DTCH data queued on the downlink or uplink.

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in buffer at
sampling time.

Explanation

Number of UEs for which there is buffered data in MAC, RLC or PDCP
protocol layers for Data Radio Bearer of traffic class at sampling time. The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current actives
UEs is larger than the prior at sampling point.

10.9.1.3.38 C374584349 Average Active User Number on User Plane


Definition

The counter is used to count the average number of UEs that have DTCH
data queued on the downlink or the uplink.

Sampling Interval

100 ms

Counter Type

Average

10-327
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB collects the number of UEs which has data in buffer at
sampling time.

Explanation

Number of UEs for which there is buffered data in MAC, RLC or


PDCP protocol layers for Data Radio Bearer of traffic class at sampling
time.The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by accumulating all the sample active UEs, and
then dividing the sum by the measurement period.

10.9.2 Active State Number on Cell


10.9.2.1 Flow Charts and Sampling Points
No chart.

10.9.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C374584336

Maximum Active State User Number

C374584337

Minimum Active State User Number

C374584338

Average Active State User Number

10.9.2.3 Counter Description


10.9.2.3.1 C374584336 Maximum Active State User Number
Definition

The counter is used to count maximum number of UEs that the state is
"active".

Sampling Interval

100 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

10-328
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 10 Statistics of Traffic QoS

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user is active
when having traffic and DRX high level.Otherwise the user is inactive.The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current active
state UEs is larger than the prior at sampling point.

10.9.2.3.2 C374584337 Minimum Active State User Number


Definition

The counter is used to count minimum number of UEs that the state is
"active".

Sampling Interval

100 ms

Counter Type

Minimum

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user is active
when having traffic and DRX high level.Otherwise the user is inactive.The
counter provides the minimum value in the measurement period.

Updated

The counter is replaced with the current value when the current active
state UEs is smaller than the prior at sampling point.

10.9.2.3.3 C374584338 Average Active State User Number


Definition

The counter is used to count average number of UEs that the state is
"active".

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state"
at sampling time.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user
is active when having traffic and DRX high level.Otherwise the user is
inactive.The counter provides the average value of all sampling point in the
measurement period.

10-329
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is updated by accumulating all the sample active state UEs,
and then dividing the sum by the measurement period.

10-330
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11

Statistics of Radio Resources


Table of Contents
DL Transmit Power...................................................................................................11-2
Received Signal Strength Indication .........................................................................11-4
Power Headroom .....................................................................................................11-5
PRB Usage ............................................................................................................ 11-11
PRB Usage(PLMN) ................................................................................................ 11-28
SPS ....................................................................................................................... 11-30
SINR ...................................................................................................................... 11-35
BLER ..................................................................................................................... 11-36
Scheduled User Number ........................................................................................ 11-42
Sub-band CQI ........................................................................................................ 11-44
Modulation Scheme................................................................................................ 11-62
MIMO Usage .......................................................................................................... 11-65
CCE Aggregation ................................................................................................... 11-71
TA .......................................................................................................................... 11-74
Msg2 ...................................................................................................................... 11-81
NI ........................................................................................................................... 11-82
ICIC...................................................................................................................... 11-169
TTI Bundling......................................................................................................... 11-197

11-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.1 DL Transmit Power


11.1.1 Flow Charts and Sampling Points
Figure 11-1 DL Transmit Power

Sampling point 1: Record the actual power of PDSCH within Type A and Type B
symbols, and then choose the larger one as the sample value.

Type A: OFDM symbols without RS

Type B: OFDM symbols with RS

11.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373414550

Maximum DL Transmit Power Per Cell

C373414551

Minimal DL Transmit Power Per Cell

C373414552

Average DL Transmit Power Per Cell

11-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.1.3 Counter Description


11.1.3.1 C373414550 Maximum DL Transmit Power Per Cell
Definition

The counter is used to count the maximum transmit power on the downlink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

mW

Measurement Object

Cell

Sampling Point

When the eNodeB collects the power of TypeA and TypeB At sampling
time, and then selects the larger between TypeA and TypeB.

Explanation

The eNodeB collects the DL power at per sampling time.The counter take
the maximum of DL power among sampling points.

Updated

The counter is replaced with the current value when the current DL power
is larger than the prior at sampling point.

11.1.3.2 C373414551 Minimal DL Transmit Power Per Cell


Definition

The counter is used to count the minimum transmit power on the downlink.

Sampling Interval

1 ms

Counter Type

Minimum

Unit

mW

Measurement Object

Cell

Sampling Point

When the eNodeB collects the power of TypeA and TypeB At sampling
time, and then selects the larger between TypeA and TypeB.

Explanation

The eNodeB collects the DL power at per sampling time.The counter take
the minimum of DL power among sampling points.

Updated

The counter is replaced with the current value when the current DL power
is smaller than the prior at sampling point.

11.1.3.3 C373414552 Average DL Transmit Power Per Cell


Definition

The counter is used to count the average transmit power on the downlink.

Sampling Interval

1 ms

Counter Type

Average

Unit

mW

Measurement Object

Cell
11-3

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB collects the power of TypeA and TypeB At sampling
time, and then select the larger between TypeA and TypeB.

Explanation

The eNodeB collects the DL power at per sampling time.The counter take
the average of DL power among sampling points.

Updated

The counter is updated by accumulating all the sample DL power, and then
dividing the sum by the measurement period.

11.2 Received Signal Strength Indication


11.2.1 Flow Charts and Sampling Points
No chart.

11.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373910000

Maximum RSSI

C373910001

Minimum RSSI

C373910002

Average RSSI

11.2.3 Counter Description


11.2.3.1 C373910000 Maximum RSSI
Definition

The counter is used to count the maximum RSSI on the uplink.

Sampling Interval

10 s

Counter Type

Maximum

Unit

dBm

Measurement Object

AntPort

Sampling Point

The eNodeB RRU collects the received power at sampling time.

Explanation

The eNodeB RRU samples the received power once at each sampling
point. After the report period expires, it reports the maximum receiving
power value of the report period.

Updated

The counter is replaced with the current value when the current RSSI is
larger than the prior at sampling point.

11-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.2.3.2 C373910001 Minimum RSSI


Definition

The counter is used to count the minimum RSSI on the uplink.

Sampling Interval

10 s

Counter Type

Minimum

Unit

dBm

Measurement Object

AntPort

Sampling Point

The eNodeB RRU collects the received power at sampling time.

Explanation

The eNodeB RRU samples the receiving power once at each sampling
point. After the report period expires, it reports the minimum receiving
power value of the report period.

Updated

The counter is replaced with the current value when the current RSSI is
smaller than the prior at sampling point.

11.2.3.3 C373910002 Average RSSI


Definition

The counter is used to count the average RSSI on the uplink.

Sampling Interval

10 s

Counter Type

Average

Unit

dBm

Measurement Object

AntPort

Sampling Point

The eNodeB RRU collects the received power at sampling time.

Explanation

The eNodeB RRU samples the receiving power once at each sampling
point. After the report period expires, it reports the average receiving
power value of the report period.

Updated

The counter is updated by accumulating all the sample RSSI, and then
dividing the sum by the measurement period.

11.3 Power Headroom


11.3.1 Flow Charts and Sampling Points
The Power Headroom reported by UE indicates the difference between UE transmit power
and maximum UE transmit power. The following section provide the distribution of power
headroom.

11-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373414576

Number of Power Headroom Reported by UE in the range of -23 to -11

C373414577

Number of Power Headroom Reported by UE in the range of -10 to -6

C373414578

Number of Power Headroom Reported by UE in the range of -5 to -1

C373414579

Number of Power Headroom Reported by UE in the range of 0 to 5

C373414580

Number of Power Headroom Reported by UE in the range of 6 to 10

C373414581

Number of Power Headroom Reported by UE in the range of 11 to 15

C373414582

Number of Power Headroom Reported by UE in the range of 16 to 20

C373414583

Number of Power Headroom Reported by UE in the range of 21 to 25

C373414584

Number of Power Headroom Reported by UE in the range of 26 to 40

10

C373414585

Number of Power Headroom Reported by UE lower than -23

11

C373414586

Number of Power Headroom Reported by UE higher than 40

11.3.3 Counter Description


11.3.3.1 C373414576 Number of Power Headroom Reported by UE in the range of
-23 to -11
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of -23 to -11.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of -23 to -11.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of -23 to -11,the counter is
increased by 1.

11-6
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.3.3.2 C373414577 Number of Power Headroom Reported by UE in the range of


-10 to -6
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of -10 to -6.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of -10 to -6.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of -10 to -6,the counter is increased
by 1.

11.3.3.3 C373414578 Number of Power Headroom Reported by UE in the range of -5


to -1
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of -5 to -1.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of -5 to -1.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of -5 to -1,the counter is increased
by 1.

11.3.3.4 C373414579 Number of Power Headroom Reported by UE in the range of 0 to 5


Definition

The counter is used to count the number of UE reported Power Headroom


within the range of 0 to 5.

11-7
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of 0 to 5.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of 0 to 5,the counter is increased
by 1.

11.3.3.5 C373414580 Number of Power Headroom Reported by UE in the range of 6


to 10
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of 6 to 10.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of 6 to 10.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of 6 to 10,the counter is increased
by 1.

11.3.3.6 C373414581 Number of Power Headroom Reported by UE in the range of


11 to 15
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of 11 to 15.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times
11-8

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of 11 to 15.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of 11 to 15,the counter is increased
by 1.

11.3.3.7 C373414582 Number of Power Headroom Reported by UE in the range of


16 to 20
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of 16 to 20.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of 16 to 20.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of 16 to 20,the counter is increased
by 1.

11.3.3.8 C373414583 Number of Power Headroom Reported by UE in the range of


21 to 25
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of 21 to 25.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

11-9
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of 21 to 25.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of 21 to 25,the counter is increased
by 1.

11.3.3.9 C373414584 Number of Power Headroom Reported by UE in the range of


26 to 40
Definition

The counter is used to count the number of UE reported Power Headroom


within the range of 26 to 40.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between UE


transmit power and maximum UE transmit power. The counter shows the
number of Power Headroom whithin the range of 26 to 40.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is whithin the range of 26 to 40,the counter is increased
by 1.

11.3.3.10 C373414585 Number of Power Headroom Reported by UE lower than -23


Definition

The counter is used to count the number of UE reported Power Headroom


lower than -23.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom

Explanation

The Power Headroom reported by UE indicates the difference between


UE transmit power and maximum UE transmit power. The counter shows
the number of Power Headroom lower than -23.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is lower than -23, the counter is increased by 1.
11-10

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.3.3.11 C373414586 Number of Power Headroom Reported by UE higher than 40


Definition

The counter is used to count the number of UE reported Power Headroom


higher than 40.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the TB including MACCE Power Headroom.

Explanation

The Power Headroom reported by UE indicates the difference between


UE transmit power and maximum UE transmit power. The counter shows
the number of Power Headroom higher than 40.

Updated

When the eNodeB receives the TB including MACCE Power Headroom


and the PHR value is higher than 40, the counter is increased by 1.

11.4 PRB Usage


11.4.1 Flow Charts and Sampling Points
No chart.

11.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373424600

PRB Number Used on PUSCH Channel

C373424601

PRB Number Available on PUSCH Channel

C373424602

PRB Number Used on PDSCH Channel

C373424603

PRB Number Available on PDSCH Channel

C373424604

CCE Number Used on PDCCH Channel

C373424605

CCE Number Available on PDCCH Channel

C373424606

Peak PRB Usage for PUSCH

C373424607

Peak PRB Usage for PDSCH

C373424608

PRB Number Used on Uplink Channel

10

C373424609

PRB Number Available on Uplink Channel

11

C373424610

PRB Number Used on Downlink Channel

12

C373424611

PRB Number Available on Downlink Channel


11-11

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
13

C373424621

QCI1 DL PRB Usage for Traffic

14

C373424622

QCI2 DL PRB Usage for Traffic

15

C373424623

QCI3 DL PRB Usage for Traffic

16

C373424624

QCI4 DL PRB Usage for Traffic

17

C373424625

QCI5 DL PRB Usage for Traffic

18

C373424626

QCI6 DL PRB Usage for Traffic

19

C373424627

QCI7 DL PRB Usage for Traffic

20

C373424628

QCI8 DL PRB Usage for Traffic

21

C373424629

QCI9 DL PRB Usage for Traffic

22

C373424630

UL Peak PRB Usage

23

C373424631

DL Peak PRB Usage

24

C373424634

UL RACH RBs

25

C373424635

UL DCCH RBs

26

C373424636

UL DTCH RBs

27

C373424637

DL PCCH RBs

28

C373424638

DL BCCH RBs

29

C373424639

DL DCCH RBs

30

C373424640

DL DTCH RBs

31

C373424641

PRB Number Used on PUSCH Channel within The Threshold

32

C373424642

PRB Number Used on PDSCH Channel within The Threshold

33

C373444750

Number of Successful Access Using Group A Preamble

34

C373444751

Number of Successful Access Using Group B Preamble

35

C373444752

Number of Successful Access Using Dedicated Preamble

11.4.3 Counter Description


11.4.3.1 C373424600 PRB Number Used on PUSCH Channel
Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the uplink for DTCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

11-12
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB uplink scheduler schedule TB and assign the PRB in


PUSCH channel.

Explanation

It is all available PRBs that eNodeB have assigned for PUSCH on the
uplink.

Updated

The counter is increased by the assigned PRB number for PUSCH at


sampling point.

11.4.3.2 C373424601 PRB Number Available on PUSCH Channel


Definition

The counter is used to count the PRB number available on PUSCH


Channel.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collect the available PRB number for PUSCH at sampling
point.

Explanation

It is PRB number that eNodeB allocates for PUSCH channel, is equal to


the PRB number for system bandwidth minus the PRB number for PUCCH.

Updated

The counter is increased by the available PRB number for PUSCH at


sampling point.

11.4.3.3 C373424602 PRB Number Used on PDSCH Channel


Definition

The counter is used to count physical resource blocks (PRBs) on the


downlink for DTCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB downlink scheduler schedule TB and assign the PRB


in PDSCH channel.

Explanation

It is all available PRBs that eNodeB have assigned for PDSCH on the
downlink.

11-13
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is increased by the PRB number used for PDSCH channel at
sampling point.

11.4.3.4 C373424603 PRB Number Available on PDSCH Channel


Definition

The counter is used to count the number of available PRB in PDSCH.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB collect the available PRB number for PDSCH at sampling
point.

Explanation

It is PRB number that eNodeB allocates for PDSCH channel, is equal to


the PRB number for system bandwidth on the downlink.

Updated

The counter is increased by the available PRB number for PDSCH at


sampling point.

11.4.3.5 C373424604 CCE Number Used on PDCCH Channel


Definition

The counter is used to count the number of allocated CCEs on PDCCH


channel.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB calculates the number of CCEs that each DCI uses in each
TTI.

Explanation

The counter counts the number of CCEs that the eNodeB allocates to the
PDCCH. It includes DCI0, DCI1, DCI1A, and DCI2. The number of used
CCEs = The number of allocated DCIs (including the uplink DCI0 and the
downlink DCI) * The number of CCE that one DCI occupies

Updated

The counter is updated by adding the previous value and the number of
measured CCEs in each TTI.

11-14
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.4.3.6 C373424605 CCE Number Available on PDCCH Channel


Definition

The counter is used to count the number of available CCEs on PDCCH


channel.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB calculates the number of CCEs that each DCI uses in each
TTI.

Explanation

The eNodeB uplink scheduler calculates the number of available CCEs


on the basis of the CFI and system bandwidth reported by the UE.The
number of avaiable CCEs on PDCCH = (The number of available REGs The number of REGs occupied by PHICH - The number of REGs occupied
by PCFICH)/9

Updated

The counter is updated by adding the previous value and the number of
CCEs when the CFI is received from the UE.

11.4.3.7 C373424606 Peak PRB Usage for PUSCH


Definition

The counter is used to count the peak usage (in percentage) of physical
resource blocks (PRBs) on the uplink for DTCH traffic.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about PUSCH channel.

Explanation

The eNodeB caculates the PRB usage about uplink channel.Detailed


Definitions:
the number of PRB for transport block / the total number of available PRB
for PUSCH.

Updated

The counter is replaced with the current when the current PUSCH PRB
usage is larger than the prior at sampling point.

11.4.3.8 C373424607 Peak PRB Usage for PDSCH


Definition

The counter is used to count the peak usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic.

11-15
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1 ms

Counter Type

Maximum

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about PDSCH channel.

Explanation

The eNodeB caculates the PRB usage about uplink channel.Detailed


Definitions:
the number of PRB for transport block / the total number of available PRB
for PDSCH.

Updated

The counter is replaced with the current when the current PDSCH PRB
usage is larger than the prior at sampling point.

11.4.3.9 C373424608 PRB Number Used on Uplink Channel


Definition

The counter is used to count The counter is used to count the number of
physical resource blocks (PRBs) on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB uplink scheduler schedule the TB for uplink channel.

Explanation

It is all available PRBs that eNodeB have assigned for uplink channel. The
channel includes PRACH,PUCCH and PUSCH.

Updated

The counter is increased by the PRB number used for uplink channel at
sampling point.

11.4.3.10 C373424609 PRB Number Available on Uplink Channel


Definition

The counter is used to count the total number of physical resource blocks
(PRBs) on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB uplink scheduler assign PRB for uplink channel.

11-16
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Explanation

It is PRB number that eNodeB allocates for uplink channel, is equal to the
PRB number for system banwidth.

Updated

The counter is increased by the PRB number allocated for uplink channel
at sampling point.

11.4.3.11 C373424610 PRB Number Used on Downlink Channel


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB downlink scheduler schedule TB and assign the PRB


in downlink channel.

Explanation

It is all available PRBs that eNodeB have assigned for downlink channel.

Updated

The counter is increased by the PRB number used for PDSCH channel at
sampling point.

11.4.3.12 C373424611 PRB Number Available on Downlink Channel


Definition

The counter is used to count The counter is used to count the total number
of physical resource blocks (PRBs) on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB downlink scheduler assign PRB for the PDSCH channel.

Explanation

It is PRB number that eNodeB allocates for downlink channel, is equal to


the PRB number for system banwidth on the downlink.

Updated

The counter is increased by the available PRB number in PDSCH channel


at sampling point.

11.4.3.13 C373424621 QCI1 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=1.
11-17

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI1 traffic.

Explanation

The eNodeB caculates the PRB usage about QCI1 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 1/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI1 PRB usage during


measument period.

11.4.3.14 C373424622 QCI2 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=2.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI2 traffic.

Explanation

The eNodeB caculates the PRB usage about QCI2 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 2/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI2 PRB usage during


measument period.

11.4.3.15 C373424623 QCI3 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=3.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent
11-18

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI3 traffic.

Explanation

The eNodeB caculates the PRB usage about QCI3 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 3/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI3 PRB usage during


measument period.

11.4.3.16 C373424624 QCI4 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=4.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI4 traffic.

Explanation

The eNodeB caculates the PRB usage about QCI4 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 4/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI4 PRB usage during


measument period.

11.4.3.17 C373424625 QCI5 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=5.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI5 traffic.

11-19
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The eNodeB caculates the PRB usage about QCI5 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 5/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI5 PRB usage during


measument period.

11.4.3.18 C373424626 QCI6 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=6.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI6 traffic.

Explanation

The eNodeB caculates the PRB usage about QCI6 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 6/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI6 PRB usage during


measument period.

11.4.3.19 C373424627 QCI7 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=7.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI7 traffic.

11-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Explanation

The eNodeB caculates the PRB usage about QCI7 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 7/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI7 PRB usage during


measument period.

11.4.3.20 C373424628 QCI8 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=8.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI8 traffic.

Explanation

The eNodeB caculates the PRB usage about QCI8 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 8/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI8 PRB usage during


measument period.

11.4.3.21 C373424629 QCI9 DL PRB Usage for Traffic


Definition

The counter is used to count the mean usage (in percentage) of physical
resource blocks (PRBs) on the downlink for DTCH traffic with QCI=9.

Sampling Interval

1 ms

Counter Type

Average

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about QCI9 traffic.

11-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The eNodeB caculates the PRB usage about QCI9 traffic.


Detailed Definitions:
(The number of bits for DTCHs with QCI = 9/ The number of bits carried in
transport block) *(the number of PRB for transport block / the total number
of available PRB for PDSCH.

Updated

The counter is updated by the average of QCI9 PRB usage during


measument period.

11.4.3.22 C373424630 UL Peak PRB Usage


Definition

The counter is used to count the peak usage (in percentage) of physical
resource blocks (PRBs) on the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about uplink channel.

Explanation

The eNodeB caculates the PRB usage about uplink channel.


Detailed Definitions:
the number of PRB for transport block / the total number of available PRB
for PUSCH.

Updated

The counter is replaced with the current when the current UL PRB usage is
larger than the prior at sampling point.

11.4.3.23 C373424631 DL Peak PRB Usage


Definition

The counter is used to count the peak usage (in percentage) of physical
resource blocks (PRBs) on the downlink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

Percent

Measurement Object

Cell

Sampling Point

The eNodeB caculates the PRB usage about downlink channel.

Explanation

The eNodeB caculates the PRB usage about downlink channel.


Detailed Definitions:
the number of PRB for transport block / the total number of available PRB
for PDSCH.

11-22
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Updated

The counter is replaced with the current when the current DL PRB usage is
larger than the prior at sampling point.

11.4.3.24 C373424634 UL RACH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on RACH channel.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the Msg1 from the UE.

Explanation

It is all available PRBs that eNodeB have assigned for RACH on the uplink.

Updated

When the eNodeB receives the Msg1 from the UE,the counter is increased
by the PRB number allocated for it.

11.4.3.25 C373424635 UL DCCH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the uplink for DCCH channel.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the SRB data is scheduled by eNodeB uplink scheduler.

Explanation

It is all available PRBs that eNodeB have assigned for DCCH on the uplink.

Updated

When the SRB data is scheduled by eNodeB uplink scheduler,the counter


is increased by the PRB number allocated for it.

11.4.3.26 C373424636 UL DTCH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the uplink for DTCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit
11-23

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the traffic data is scheduled by eNodeB uplink scheduler.

Explanation

It is all available PRBs that eNodeB have assigned for DTCH on the uplink.

Updated

When the traffic data is scheduled by eNodeB uplink scheduler,the counter


is increased by the PRB number allocated for it.

11.4.3.27 C373424637 DL PCCH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink for paging traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the paging message is scheduled by eNodeB downlink scheduler.

Explanation

It is all available PRBs that eNodeB have assigned for PCCH on the
downlink.

Updated

When the paging message is scheduled by eNodeB downlink scheduler,the


counter is increased by the PRB number allocated for it.

11.4.3.28 C373424638 DL BCCH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink for BCCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the broadcast message is scheduled by eNodeB downlink scheduler.

Explanation

It is all available PRBs that eNodeB have assigned for BCCH on the
downlink.

Updated

When the broadcast message is scheduled by eNodeB downlink


scheduler,the counter is increased by the PRB number allocated for it.

11-24
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.4.3.29 C373424639 DL DCCH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink for DCCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the SRB data is scheduled by eNodeB downlink scheduler.

Explanation

It is all available PRBs that eNodeB have assigned for DCCH on the
downlink.

Updated

When the SRB data is scheduled by eNodeB downlink scheduler,the


counter is increased by the PRB number allocated for it.

11.4.3.30 C373424640 DL DTCH RBs


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink for DTCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the traffic data is scheduled by eNodeB downlink scheduler.

Explanation

It is all available PRBs that eNodeB have assigned for DTCH on the
downlink.

Updated

When the traffic data is scheduled by eNodeB downlink scheduler,the


counter is increased by the PRB number allocated for it.

11.4.3.31 C373424641 PRB Number Used on PUSCH Channel within The Threshold
Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the uplink for DTCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

11-25
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When there are uplink PRB used for the PUSCH, and the threshold
requirements for RSRP and SINR must be satisfied. Users can set these
threshold values, and the default threshold requirements are: RSRP
> Threshold for RSRP Statistics and SINR > Threshold for DL SINR
Statistics.

Explanation

The counter displays the allocated RB number when eNB sends DCI0
or MSG 2 at the sample moment and the reserved RB number during
non-adaptive retransmission or SPS scheduling.

Updated

The counter is updated by the new data during UL data transmission.

11.4.3.32 C373424642 PRB Number Used on PDSCH Channel within The Threshold
Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink for DTCH traffic.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When there are downlink PRB used for the PDSCH, and the threshold
requirements for RSRP and DL SINR must be satisfied.

Explanation

The counter statics the sum number of PRB used for PDSCH channel
within the threshold,but but exclude retransmission PRB number.The
counter displays the allocated PRB number when eNB sends DCI1/1A/2/2A
at the sample moment and the reserved PRB number during non-adaptive
retransmission or SPS scheduling.Users can set these threshold values,
and the default threshold requirements are: RSRP > Threshold for RSRP
Statistics and DL SINR > Threshold for DL SINR Statistics.The RSRP
threshold is converted by Power Headroom reporting that UE reports by
means of period or event trigger.The DL SINR threshold is converted by
CQI reported by UE.

Updated

The counter is updated when a new measurement value is obtained.

11.4.3.33 C373444750 Number of Successful Access Using Group A Preamble


Definition

The counter is used to count the number of RACH preambles in group A.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

11-26
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

The MAC calculates the number of Preambles reported after the PHY
detection in each TTI.

Explanation

The eNodeB uplink scheduler detects the Preamble in each TTI and the
counter counts the number of successful detections.Group A Preamble is
the Preamble whose value is lower than sizeOfRA-PreamblesGroupA.

Updated

The counter is updated by adding the previous value and the number of
measured Preambles in each TTI.

11.4.3.34 C373444751 Number of Successful Access Using Group B Preamble


Definition

The counter is used to count the number of RACH preambles in group B.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The MAC calculates the number of Preambles reported after the PHY
detection in each TTI.

Explanation

The CMAC uplink scheduler detects the Preamble in each TTI and the
counter counts the number of successful detections.Group B Preamble is
the Preamble whose value is lower than numberOfRA-Preambles and
higher than or equal to sizeOfRA-PreamblesGroupA.

Updated

The counter is updated by adding the previous value and the number of
measured Preambles in each TTI.

11.4.3.35 C373444752 Number of Successful Access Using Dedicated Preamble


Definition

The counter is used to count the number of RACH dedicated preambles.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

The MAC calculates the number of Preambles reported after the PHY
detection in each TTI.

11-27
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The eNodeB uplink scheduler detects the Preamble in each TTI and
the counter counts the number of successful detections.Dedicated
Preamble is the Preamble whose value is higher than or equal to
numberOfRA-Preambles.

Updated

The counter is updated by adding the previous value and the number of
measured Preambles in each TTI.

11.5 PRB Usage(PLMN)


11.5.1 Flow Charts and Sampling Points
No chart.

11.5.2 Counter List


NO.

Counter

Counter Name

Number
1

C374624608

PRB Number Used on Uplink Channel

C374624609

PRB Number Available on Uplink Channel

C374624610

PRB Number Used on Downlink Channel

C374624611

PRB Number Available on Downlink Channel

11.5.3 Counter Description


11.5.3.1 C374624608 PRB Number Used on Uplink Channel
Definition

The counter is used to count The counter is used to count the number of
physical resource blocks (PRBs) on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When eNodeB uplink scheduler schedule the TB for uplink channel.

Explanation

It is all available PRBs that eNodeB have assigned for uplink channel. The
channel includes PRACH,PUCCH and PUSCH.

Updated

The counter is increased by the PRB number used for uplink channel at
sampling point.
11-28

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.5.3.2 C374624609 PRB Number Available on Uplink Channel


Definition

The counter is used to count the total number of physical resource blocks
(PRBs) on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB uplink scheduler assign PRB for uplink channel.

Explanation

It is PRB number that eNodeB allocates for uplink channel, is equal to the
PRB number for system banwidth.

Updated

The counter is increased by the PRB number allocated for


uplink channel at sampling point.

11.5.3.3 C374624610 PRB Number Used on Downlink Channel


Definition

The counter is used to count the number of physical resource blocks


(PRBs) on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Logic Cell

Sampling Point

When eNodeB downlink scheduler schedule TB and assign the PRB


in downlink channel.

Explanation

It is all available PRBs that eNodeB have assigned for downlink channel.

Updated

The counter is increased by the PRB number used for PDSCH channel at
sampling point.

11.5.3.4 C374624611 PRB Number Available on Downlink Channel


Definition

The counter is used to count The counter is used to count the total number
of physical resource blocks (PRBs) on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

11-29
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When eNodeB downlink scheduler assign PRB for the PDSCH


channel.

Explanation

It is PRB number that eNodeB allocates for downlink channel, is equal to


the PRB number for system banwidth on the downlink.

Updated

The counter is increased by the available PRB number in


PDSCH channel at sampling point.

11.6 SPS
11.6.1 Flow Charts and Sampling Points
No chart.

11.6.2 Counter List


NO.

Counter

Counter Name

Number
1

C373424676

Number of UL SPS activation request

C373424677

Number of UL SPS activation completed

C373424678

Number of UL SPS reacivation request

C373424679

Number of UL SPS reactivation completed

C373424680

Number of UL SPS deacivation request

C373424681

Number of UL SPS deactivation completed

C373424682

Number of DL SPS activation request

C373424683

Number of DL SPS activation completed

C373424684

Number of DL SPS reacivation request

10

C373424685

Number of DL SPS reactivation completed

11

C373424686

Number of DL SPS deacivation request

12

C373424687

Number of DL SPS deactivation completed

11.6.3 Counter Description


11.6.3.1 C373424676 Number of UL SPS activation request
Definition

The counter is used to count the number of UL SPS activation request.

Sampling Interval

Event triggered
11-30

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UL SPS activation request.

Explanation

The counter provides the number of UL SPS activation request.

Updated

The counter is increased by 1 when the eNodeB sends the UL SPS


activation request.

11.6.3.2 C373424677 Number of UL SPS activation completed


Definition

The counter is used to count the number of UL SPS activation completed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UL SPS activation completed.

Explanation

The counter provides the number of UL SPS activation completed.

Updated

The counter is increased by 1 when the UL SPS activation completed.

11.6.3.3 C373424678 Number of UL SPS reacivation request


Definition

The counter is used to count the number of UL SPS reacivation request.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UL SPS reactivation request.

Explanation

The counter provides the number of UL SPS reacivation request.

Updated

The counter is increased by 1 when the eNodeB sends the UL SPS


reactivation request.

11.6.3.4 C373424679 Number of UL SPS reactivation completed


Definition

The counter is used to count the number of UL SPS reactivation completed.

Sampling Interval

Event triggered
11-31

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UL SPS reactivation completed.

Explanation

The counter provides the number of UL SPS reactivation completed.

Updated

The counter is increased by 1 when the UL SPS reactivation completed.

11.6.3.5 C373424680 Number of UL SPS deacivation request


Definition

The counter is used to count the number of UL SPS deacivation request.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the UL SPS deactivation request.

Explanation

The counter provides the number of UL SPS deacivation request.

Updated

The counter is increased by 1 when the eNodeB sends the UL SPS


deactivation request.

11.6.3.6 C373424681 Number of UL SPS deactivation completed


Definition

The counter is used to count the number of UL SPS deactivation


completed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the UL SPS deactivation completed.

Explanation

The counter provides the number of UL SPS deactivation completed.

Updated

The counter is increased by 1 when the UL SPS deactivation completed.

11.6.3.7 C373424682 Number of DL SPS activation request


Definition

The counter is used to count the number of DL SPS activation request.

Sampling Interval

Event triggered
11-32

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the DL SPS activation request.

Explanation

The counter provides the number of DL SPS activation request.

Updated

The counter is increased by 1 when the eNodeB sends the DL SPS


activation request.

11.6.3.8 C373424683 Number of DL SPS activation completed


Definition

The counter is used to count the number of DL SPS activation completed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the DL SPS activation completed.

Explanation

The counter provides the number of DL SPS activation completed.

Updated

The counter is increased by 1 when the DL SPS activation completed.

11.6.3.9 C373424684 Number of DL SPS reacivation request


Definition

The counter is used to count the number of DL SPS reacivation request.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the DL SPS reactivation request.

Explanation

The counter provides the number of DL SPS reacivation request.

Updated

The counter is increased by 1 when the eNodeB sends the DL SPS


reactivation request.

11.6.3.10 C373424685 Number of DL SPS reactivation completed


Definition

The counter is used to count the number of DL SPS reactivation completed.

Sampling Interval

Event triggered
11-33

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the DL SPS reactivation completed.

Explanation

The counter provides the number of DL SPS reactivation completed.

Updated

The counter is increased by 1 when the DL SPS reactivation completed.

11.6.3.11 C373424686 Number of DL SPS deacivation request


Definition

The counter is used to count the number of DL SPS deacivation request.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the DL SPS deactivation request.

Explanation

The counter provides the number of DL SPS deacivation request.

Updated

The counter is increased by 1 when the eNodeB sends the DL SPS


deactivation request.

11.6.3.12 C373424687 Number of DL SPS deactivation completed


Definition

The counter is used to count the number of DL SPS deactivation


completed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the DL SPS deactivation completed.

Explanation

The counter provides the number of DL SPS deactivation completed.

Updated

The counter is increased by 1 when the DL SPS deactivation completed.

11-34
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.7 SINR
11.7.1 Flow Charts and Sampling Points
No chart.

11.7.2 Counter List


NO.

Counter

Counter Name

Number
1

C373444754

Average UL SINR(Linear Value)

C373444760

Average UL SINR(DB Value)

11.7.3 Counter Description


11.7.3.1 C373444754 Average UL SINR(Linear Value)
Definition

The counter is used to count the average of SINR.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB's PHY layer receives the UL data, measure the SINR
on every used PRB.

Explanation

The counter provides the mean SINR linear value of used PRB.

Updated

The counter is updated by accumulating all the sample SINR linear value
and then dividing the sum by the measurement period.

11.7.3.2 C373444760 Average UL SINR(DB Value)


Definition

The counter is used to count the average of SINR(db).

Sampling Interval

15 min

Counter Type

Average

Unit

dB

Measurement Object

Cell

Sampling Point

When the eNodeB's PHY layer receives the UL data, measure the SINR
on every used PRB.
11-35

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the mean SINR of used PRB.

Updated

The counter is updated by accumulating all the sample SINR and then
dividing the sum by the measurement period.

11.8 BLER
11.8.1 Flow Charts and Sampling Points
Figure 11-2 BLER

11.8.2 Counter List


NO.

Counter

Counter Name

Number
1

C373454800

Error Number of DL TBs

C373454801

Total Number of DL TBs

C373454802

Error Number of UL TBs

C373454803

Total Number of UL TBs

C373454804

Error Number of DL Init TBs

C373454805

Total Number of DL Init TBs

C373454806

Error Number of UL Init TBs

C373454807

Total Number of UL Init TBs

C373454818

Total Number of DL TBs that include RRC Release Msg

11-36
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

NO.

Counter

Counter Name

Number
10

C373454819

Error Number of DL TBs that include RRC Release Msg

11

C373454820

Total Number of DL TBs that include RRC Reconfig Msg in HO

12

C373454821

Error Number of DL TBs that include RRC Reconfig Msg in HO

11.8.3 Counter Description


11.8.3.1 C373454800 Error Number of DL TBs
Definition

The counter is used to count the number of error TBs transmitted on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty receiption of TB


by UE.

Explanation

After the eNodeB send a transport block to the UE, it will receive HARQ
feedback information from the UE. If the HARQ feedback is NACK or DTX,
it is added to the counter.

Updated

The counter is incremented by 1 when eNB receives a NACK or DTX


HARQ feedback.

11.8.3.2 C373454801 Total Number of DL TBs


Definition

The counter is used to count the total number of TBs transmitted on the
downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for DL data.

Explanation

After the eNodeB send a transport block to the UE, it will receive HARQ
feedback information from the UE. No matter the HARQ feedback is
ACK,NACK or DTX, it is added to the counter.

11-37
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when eNB schedules one TB for DL data.

11.8.3.3 C373454802 Error Number of UL TBs


Definition

The counter is used to count the number of error TBs transmitted on the
uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB sends a NACK or DTX indicating a faulty reception of TB to


UE.

Explanation

After the eNodeB received a transport block from the UE, it will reply
HARQ feedback information to the UE. If the HARQ feedback is NACK
or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNB detects a CRC error TB.

11.8.3.4 C373454803 Total Number of UL TBs


Definition

The counter is used to count the total number of TBs transmitted on the
uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for UL data.

Explanation

After the eNodeB received a transport block from the UE, it will reply
HARQ feedback information to the UE. No matter the HARQ feedback is
ACK,NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNB schedules one TB for UL data.

11.8.3.5 C373454804 Error Number of DL Init TBs


Definition

The counter is used to count the number of error TBs first transmitted
on the downlink.

Sampling Interval

15 min

11-38
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty receiption of TB


by UE and the TB is transmitted.

Explanation

After the eNodeB first send a transport block to the UE, it will receive
HARQ feedback information about the TB from the UE. If the HARQ
feedback is NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNB receives a NACK or DTX of


init TB.

11.8.3.6 C373454805 Total Number of DL Init TBs


Definition

The counter is used to count the total number of TBs first transmitted on
the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for DL data.

Explanation

After the eNodeB first send a transport block to the UE, it will receive
HARQ feedback information from the UE. No matter the HARQ feedback
is ACK,NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNB schedules one init TB for DL


data.

11.8.3.7 C373454806 Error Number of UL Init TBs


Definition

The counter is used to count the number of error TBs first transmitted
on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty receiption of TB


by UE.

11-39
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

After the eNodeB first received a transport block from the UE, it will reply
HARQ feedback information to the UE. If the HARQ feedback is NACK
or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNB detectes a CRC error init TB.

11.8.3.8 C373454807 Total Number of UL Init TBs


Definition

The counter is used to count the total number of TBs first transmitted on
the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for UL data.

Explanation

After the eNodeB first received a transport block from the UE, it will reply
HARQ feedback information to the UE. No matter the HARQ feedback is
ACK,NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNB schedules one init TB for UL


data.

11.8.3.9 C373454818 Total Number of DL TBs that include RRC Release Msg
Definition

The counter is used to count the number of TBs including the


RRCConnectionRelease message on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for DL data and the RRCConnectionRelease


message is included in the TB.

Explanation

After the eNodeB sends a transmission block including the


RRCConnectionRelease message to the UE, it will receive HARQ
feedback information from the UE. No matter the HARQ feedback is
ACK,NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNodeB schedules a TB for DL data


and the RRCConnectionRelease message is included in the TB.

11-40
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.8.3.10 C373454819 Error Number of DL TBs that include RRC Release Msg
Definition

The counter is used to count the number of faulty TBs including the
RRCConnectionRelease message on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty receiption of TB


by UE and the RRCConnectionRelease message is included in the TB.

Explanation

After the eNodeB received a transport block including the


RRCConnectionRelease message from the UE, it will reply HARQ
feedback information to the UE. If the HARQ feedback is NACK or DTX,
it is added to the counter.

Updated

The counter is incremented by 1 when eNodeB receives a NACK or DTX


indicating a faulty receiption of TB by UE and the RRCConnectionRelease
message is included in the TB.

11.8.3.11 C373454820 Total Number of DL TBs that include RRC Reconfig Msg in HO
Definition

The counter is used to count the number of TBs including the


RRCConnectionReconfiguration message for handover on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for DL data and the RRCConnectionReconfiguration message for handover is included in the TB.

Explanation

After the eNodeB sends a transmission block including the


RRCConnectionReconfiguration message for handover to the UE, it will
receive HARQ feedback information from the UE. No matter the HARQ
feedback is ACK,NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNodeB schedules a TB for DL


data and the RRCConnectionReconfiguration message for handover is
included in the TB.

11-41
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.8.3.12 C373454821 Error Number of DL TBs that include RRC Reconfig Msg in HO
Definition

The counter is used to count the number of faulty TBs including the
RRCConnectionReconfiguration message for handover on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty receiption of


TB by UE and the RRCConnectionReconfiguration message for handover
is included in the TB.

Explanation

After the eNodeB received a transport block including the


RRCConnectionReconfiguration message for handover from the UE, it will
reply HARQ feedback information to the UE. If the HARQ feedback is
NACK or DTX, it is added to the counter.

Updated

The counter is incremented by 1 when eNodeB receives a


NACK or DTX indicating a faulty receiption of TB by UE and the
RRCConnectionReconfiguration message for handover is included in the
TB.

11.9 Scheduled User Number


11.9.1 Flow Charts and Sampling Points
The Scheduled User per TTI reflects the processing capability of eNodeB scheduler.
This sector provides the scheduled user number on downlink and uplink.

11.9.2 Counter List


NO.

Counter

Counter Name

Number
1

C373384339

Maximum DL User Number Scheduled Per TTI

C373384341

Maximum UL User Number Scheduled Per TTI

C373384350

Total Number of UL Scheduled User

C373384351

Total Number of DL Scheduled User

11-42
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.9.3 Counter Description


11.9.3.1 C373384339 Maximum DL User Number Scheduled Per TTI
Definition

The counter is used to count maximum number of UEs sheduled in DL


per TTI.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB DL sheduler collects the number of sheduled UEs in DL per


TTI.

Explanation

The value is obtained by sampling at a 1ms interval, the number of


scheduled user on the downlink and then taking the maximum.

Updated

The counter is replaced with the current value when the current active
state UEs is larger than the prior at sampling point.

11.9.3.2 C373384341 Maximum UL User Number Scheduled Per TTI


Definition

The counter is used to count maximum number of UEs sheduled in UL


per TTI.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB UL sheduler collects the number of sheduled UEs in UL per


TTI.

Explanation

The value is obtained by sampling at a 1ms interval, the number of


scheduled user on the uplink and then taking the maximum.

Updated

The counter is replaced with the current value when the current active
state UEs is larger than the prior at sampling point.

11.9.3.3 C373384350 Total Number of UL Scheduled User


Definition

The counter is used to count the total number of scheduled UEs in UL.

Sampling Interval

1 ms

Counter Type

Accumulative

11-43
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB UL scheduler collects the total number of scheduled UEs in


UL.

Explanation

The value is obtained by sampling at a 1 ms interval, the total number of


UL scheduled user on the uplink and then taking the sum.

Updated

The counter is updated by accumulating all the sample active state UEs.

11.9.3.4 C373384351 Total Number of DL Scheduled User


Definition

The counter is used to count the total number of scheduled UEs in DL.

Sampling Interval

1 ms

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB DL scheduler collects the total number of scheduled UEs in


DL.

Explanation

The value is obtained by sampling at a 1 ms interval, the total number of


DL scheduled user on the downlink and then taking the sum.

Updated

The counter is updated by accumulating all the sample active state UEs.

11.10 Sub-band CQI


11.10.1 Flow Charts and Sampling Points
A subband is a set of k contiguous PRBs where k is a function of system bandwidth. Note
the last subband in set S may have fewer than k contiguous PRBs depending on NRBDL. The
number of subbands for system bandwidth given by NRBDL is defined by N=[NRBDL/k].The
subbands shall be indexed in the order of increasing frequency and non-increasing sizes
starting at the lowest frequency.
Subband Size k(RBs)

System Bandwidth
NRBDL
67

NA

810

1126

2763

3
11-44

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

System Bandwidth

Subband Size k(RBs)

NRBDL
64110

11.10.2 Counter List


NO.

Counter

Counter Name

Number
1

C373434700

Number of CQI0 Be Used

C373434701

Number of CQI1 Be Used

C373434702

Number of CQI2 Be Used

C373434703

Number of CQI3 Be Used

C373434704

Number of CQI4 Be Used

C373434705

Number of CQI5 Be Used

C373434706

Number of CQI6 Be Used

C373434707

Number of CQI7 Be Used

C373434708

Number of CQI8 Be Used

10

C373434709

Number of CQI9 Be Used

11

C373434710

Number of CQI10 Be Used

12

C373434711

Number of CQI11 Be Used

13

C373434712

Number of CQI12 Be Used

14

C373434713

Number of CQI13 Be Used

15

C373434714

Number of CQI14 Be Used

16

C373434715

Number of CQI15 Be Used

17

C373434716

Average CQI of Suband 0

18

C373434717

Average CQI of Suband 1

19

C373434718

Average CQI of Suband 2

20

C373434719

Average CQI of Suband 3

21

C373434720

Average CQI of Suband 4

22

C373434721

Average CQI of Suband 5

23

C373434722

Average CQI of Suband 6

24

C373434723

Average CQI of Suband 7

25

C373434724

Average CQI of Suband 8

26

C373434725

Average CQI of Suband 9

11-45
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
27

C373434726

Average CQI of Suband 10

28

C373434727

Average CQI of Suband 11

29

C373434728

Average CQI of Suband 12

30

C373434729

Average CQI of Suband 13

31

C373434730

Average CQI of Suband 14

32

C373434731

Average CQI of Suband 15

33

C373434732

Average CQI of Suband 16

34

C373434733

Average CQI of Suband 17

35

C373434734

Average CQI of Suband 18

36

C373434735

Average CQI of Suband 19

37

C373434736

Average CQI of Suband 20

38

C373434737

Average CQI of Suband 21

39

C373434738

Average CQI of Suband 22

40

C373434739

Average CQI of Suband 23

41

C373434740

Average CQI of Suband 24

11.10.3 Counter Description


11.10.3.1 C373434700 Number of CQI0 Be Used
Definition

The counter is used to count the number of CQI0 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 0 from the UE feedback.

Explanation

The counter provides the number of CQI0 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI0


Feedback information on the PUCCH from UE.

11.10.3.2 C373434701 Number of CQI1 Be Used


Definition

The counter is used to count the number of CQI1 received by eNodeB.


11-46

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 1 from the UE feedback.

Explanation

The counter provides the number of CQI1 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI1


Feedback information on the PUCCH from UE.

11.10.3.3 C373434702 Number of CQI2 Be Used


Definition

The counter is used to count the number of CQI2 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 2 from the UE feedback.

Explanation

The counter provides the number of CQI2 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI2


Feedback information on the PUCCH from UE.

11.10.3.4 C373434703 Number of CQI3 Be Used


Definition

The counter is used to count the number of CQI3 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 3 from the UE feedback.

Explanation

The counter provides the number of CQI3 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI3


Feedback information on the PUCCH from UE.

11-47
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.10.3.5 C373434704 Number of CQI4 Be Used


Definition

The counter is used to count the number of CQI4 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 4 from the UE feedback.

Explanation

The counter provides the number of CQI4 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI4


Feedback information on the PUCCH from UE.

11.10.3.6 C373434705 Number of CQI5 Be Used


Definition

The counter is used to count the number of CQI5 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 5 from the UE feedback.

Explanation

The counter provides the number of CQI5 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI5


Feedback information on the PUCCH from UE.

11.10.3.7 C373434706 Number of CQI6 Be Used


Definition

The counter is used to count the number of CQI6 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 6 from the UE feedback.

Explanation

The counter provides the number of CQI6 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI6


Feedback information on the PUCCH from UE.

11-48
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.10.3.8 C373434707 Number of CQI7 Be Used


Definition

The counter is used to count the number of CQI7 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 7 from the UE feedback.

Explanation

The counter provides the number of CQI7 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI7


Feedback information on the PUCCH from UE.

11.10.3.9 C373434708 Number of CQI8 Be Used


Definition

The counter is used to count the number of CQI8 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 8 from the UE feedback.

Explanation

The counter provides the number of CQI8 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI8


Feedback information on the PUCCH from UE.

11.10.3.10 C373434709 Number of CQI9 Be Used


Definition

The counter is used to count the number of CQI9 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 9 from the UE feedback.

Explanation

The counter provides the number of CQI9 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI9


Feedback information on the PUCCH from UE.

11-49
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.10.3.11 C373434710 Number of CQI10 Be Used


Definition

The counter is used to count the number of CQI10 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 10 from the UE
feedback.

Explanation

The counter provides the number of CQI10 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI10


Feedback information on the PUCCH from UE.

11.10.3.12 C373434711 Number of CQI11 Be Used


Definition

The counter is used to count the number of CQI11 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 11 from the UE
feedback.

Explanation
Updated

The counter provides the number of CQI11 reported by UE.


The counter is incremented by 1 When the eNodeB receives the CQI11
Feedback information on the PUCCH from UE.

11.10.3.13 C373434712 Number of CQI12 Be Used


Definition

The counter is used to count the number of CQI12 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 12 from the UE
feedback.

Explanation

The counter provides the number of CQI12 reported by UE.

11-50
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Updated

The counter is incremented by 1 When the eNodeB receives the CQI12


Feedback information on the PUCCH from UE.

11.10.3.14 C373434713 Number of CQI13 Be Used


Definition

The counter is used to count the number of CQI13 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 13 from the UE
feedback.

Explanation

The counter provides the number of CQI13 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI13


Feedback information on the PUCCH from UE.

11.10.3.15 C373434714 Number of CQI14 Be Used


Definition

The counter is used to count the number of CQI14 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value equal to 14 from the UE
feedback.

Explanation

The counter provides the number of CQI14 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI14


Feedback information on the PUCCH from UE.

11.10.3.16 C373434715 Number of CQI15 Be Used


Definition

The counter is used to count the number of CQI15 received by eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell
11-51

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the eNodeB receives the CQI value equal to 15 from the UE
feedback.

Explanation

The counter provides the number of CQI15 reported by UE.

Updated

The counter is incremented by 1 When the eNodeB receives the CQI15


Feedback information on the PUCCH from UE.

11.10.3.17 C373434716 Average CQI of Suband 0


Definition

The counter is used to count the average of the sub-band 0 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 0.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 0.

Updated

The counter is obtained by computing the average value of the sub-band 0


CQI reported by UEs within the measurement granularity period.

11.10.3.18 C373434717 Average CQI of Suband 1


Definition

The counter is used to count the average of the sub-band 1 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 1.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 1.

Updated

The counter is obtained by computing the average value of the sub-band 1


CQI reported by UEs within the measurement period.

11-52
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.10.3.19 C373434718 Average CQI of Suband 2


Definition

The counter is used to count the average of the sub-band 2 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 2.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 2.

Updated

The counter is obtained by computing the average value of the sub-band 2


CQI reported by UEs within the measurement period.

11.10.3.20 C373434719 Average CQI of Suband 3


Definition

The counter is used to count the average of the sub-band 3 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 3.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 3.

Updated

The counter is obtained by computing the average value of the sub-band 3


CQI reported by UEs within the measurement period.

11.10.3.21 C373434720 Average CQI of Suband 4


Definition

The counter is used to count the average of the sub-band 4 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

11-53
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 4.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 4.

Updated

The counter is obtained by computing the average value of the sub-band 4


CQI reported by UEs within the measurement period.

11.10.3.22 C373434721 Average CQI of Suband 5


Definition

The counter is used to count the average of the sub-band 5 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 5.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 5.

Updated

The counter is obtained by computing the average value of the sub-band 5


CQI reported by UEs within the measurement period.

11.10.3.23 C373434722 Average CQI of Suband 6


Definition

The counter is used to count the average of the sub-band 6 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 6.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 6.

Updated

The counter is obtained by computing the average value of the sub-band 6


CQI reported by UEs within the measurement period.
11-54

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.10.3.24 C373434723 Average CQI of Suband 7


Definition

The counter is used to count the average of the sub-band 7 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 7.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 7.

Updated

The counter is obtained by computing the average value of the sub-band 7


CQI reported by UEs within the measurement period.

11.10.3.25 C373434724 Average CQI of Suband 8


Definition

The counter is used to count the average of the sub-band 8 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 8.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 8.

Updated

The counter is obtained by computing the average value of the sub-band 8


CQI reported by UEs within the measurement period.

11.10.3.26 C373434725 Average CQI of Suband 9


Definition

The counter is used to count the average of the sub-band 9 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

11-55
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 9.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 9.

Updated

The counter is obtained by computing the average value of the sub-band 9


CQI reported by UEs within the measurement period.

11.10.3.27 C373434726 Average CQI of Suband 10


Definition

The counter is used to count the average of the sub-band 10 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 10.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 10.

Updated

The counter is obtained by computing the average value of the sub-band


10 CQI reported by UEs within the measurement period.

11.10.3.28 C373434727 Average CQI of Suband 11


Definition

The counter is used to count the average of the sub-band 11 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 11.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 11.

Updated

The counter is obtained by computing the average value of the sub-band


11 CQI reported by UEs within the measurement period.
11-56

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.10.3.29 C373434728 Average CQI of Suband 12


Definition

The counter is used to count the average of the sub-band 12 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 12.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 12.

Updated

The counter is obtained by computing the average value of the sub-band


12 CQI reported by UEs within the measurement period.

11.10.3.30 C373434729 Average CQI of Suband 13


Definition

The counter is used to count the average of the sub-band 13 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 13.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 13.

Updated

The counter is obtained by computing the average value of the sub-band


13 CQI reported by UEs within the measurement period.

11.10.3.31 C373434730 Average CQI of Suband 14


Definition

The counter is used to count the average of the sub-band 14 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

11-57
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 14.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 14.

Updated

The counter is obtained by computing the average value of the sub-band


14 CQI reported by UEs within the measurement period.

11.10.3.32 C373434731 Average CQI of Suband 15


Definition

The counter is used to count the average of the sub-band 15 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 15.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 15.

Updated

The counter is obtained by computing the average value of the sub-band


15 CQI reported by UEs within the measurement period.

11.10.3.33 C373434732 Average CQI of Suband 16


Definition

The counter is used to count the average of the sub-band 16 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 16.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 16.

Updated

The counter is obtained by computing the average value of the sub-band


16 CQI reported by UEs within the measurement period.
11-58

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.10.3.34 C373434733 Average CQI of Suband 17


Definition

The counter is used to count the average of the sub-band 17 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 17.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 17.

Updated

The counter is obtained by computing the average value of the sub-band


17 CQI reported by UEs within the measurement period.

11.10.3.35 C373434734 Average CQI of Suband 18


Definition

The counter is used to count the average of the sub-band 18 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 18.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 18.

Updated

The counter is obtained by computing the average value of the sub-band


18 CQI reported by UEs within the measurement period.

11.10.3.36 C373434735 Average CQI of Suband 19


Definition

The counter is used to count the average of the sub-band 19 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

11-59
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 19.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 19.

Updated

The counter is obtained by computing the average value of the sub-band


19 CQI reported by UEs within the measurement period.

11.10.3.37 C373434736 Average CQI of Suband 20


Definition

The counter is used to count the average of the sub-band 20 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 20.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 20.

Updated

The counter is obtained by computing the average value of the sub-band


20 CQI reported by UEs within the measurement period.

11.10.3.38 C373434737 Average CQI of Suband 21


Definition

The counter is used to count the average of the sub-band 21 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 21.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 21.

Updated

The counter is obtained by computing the average value of the sub-band


21 CQI reported by UEs within the measurement period.
11-60

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.10.3.39 C373434738 Average CQI of Suband 22


Definition

The counter is used to count the average of the sub-band 22 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 22.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 22.

Updated

The counter is obtained by computing the average value of the sub-band


22 CQI reported by UEs within the measurement period.

11.10.3.40 C373434739 Average CQI of Suband 23


Definition

The counter is used to count the average of the sub-band 23 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 23.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 23.

Updated

The counter is obtained by computing the average value of the sub-band


23 CQI reported by UEs within the measurement period.

11.10.3.41 C373434740 Average CQI of Suband 24


Definition

The counter is used to count the average of the sub-band 24 CQI reported
by UEs.

Sampling Interval

15 min

Counter Type

Average

Unit

N/A

11-61
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the CQI value from the UE feedback in
sub-band 24.

Explanation

The counter provides the average value of CQI reported by UE for


sub-band 24.

Updated

The counter is obtained by computing the average value of the sub-band


24 CQI reported by UEs within the measurement period.

11.11 Modulation Scheme


11.11.1 Flow Charts and Sampling Points
Modulation Scheme: QPSK, 16QAM and 64QAM.
The dispatched transmission blocks under different modulation schemes are calculated on
downlink and uplink traffic channels.

11.11.2 Counter List


NO.

Counter

Counter Name

Number
1

C373515500

Number of DL TBs With QPSK Modulation

C373515501

Number of DL TBs With 16QAM Modulation

C373515502

Number of DL TBs With 64QAM Modulation

C373515503

Number of UL TBs With QPSK Modulation

C373515504

Number of UL TBs With 16QAM Modulation

C373515505

Number of UL TBs With 64QAM Modulation

11.11.3 Counter Description


11.11.3.1 C373515500 Number of DL TBs With QPSK Modulation
Definition

The counter is used to count the number of transport blocks with QPSK
modulation on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

11-62
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on QPSK modulation


schedule on the downlink.

Explanation

The counter provides the number of transport blocks based on QPSK


modulation schedule on the downlink.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on QPSK modulation schedule on the downlink.

11.11.3.2 C373515501 Number of DL TBs With 16QAM Modulation


Definition

The counter is used to count the number of transport blocks with 16QAM
modulation on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on 16QAM modulation


schedule on the downlink.

Explanation

The counter provides the number of transport blocks based on 16QAM


modulation schedule on the downlink.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on 16QAM modulation schedule on the downlink.

11.11.3.3 C373515502 Number of DL TBs With 64QAM Modulation


Definition

The counter is used to count the number of transport blocks with 64QAM
modulation on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on 64QAM modulation


schedule on the downlink.

Explanation

The counter provides the number of transport blocks based on 64QAM


modulation schedule on the downlink.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on 64QAM modulation schedule on the downlink.
11-63

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.11.3.4 C373515503 Number of UL TBs With QPSK Modulation


Definition

The counter is used to count the number of transport blocks with QPSK
modulation on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on QPSK modulation


schedule on the uplink.

Explanation

The counter provides the number of transport blocks based on QPSK


modulation schedule on the uplink.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on QPSK modulation schedule on the uplink.

11.11.3.5 C373515504 Number of UL TBs With 16QAM Modulation


Definition

The counter is used to count the number of transport blocks with 16QAM
modulation on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on 16QAM modulation


schedule on the uplink.

Explanation

The counter provides the number of transport blocks based on 16QAM


modulation schedule on the uplink.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on 16QAM modulation schedule on the uplink.

11.11.3.6 C373515505 Number of UL TBs With 64QAM Modulation


Definition

The counter is used to count the number of transport blocks with 64QAM
modulation on the uplink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

11-64
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on 64QAM modulation


schedule on the uplink.

Explanation

The counter provides the number of transport blocks based on 64QAM


modulation schedule on the uplink.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on 64QAM modulation schedule on the uplink.

11.12 MIMO Usage


11.12.1 Flow Charts and Sampling Points
The dispatched transmission blocks under different MIMOs are calculated on downlink
PDSCH channel.

11.12.2 Counter List


NO.

Counter

Counter Name

Number
1

C373515506

Number of DL TBs with TM1 Mode

C373515507

Number of DL TBs with TM2 Mode

C373515508

Number of DL TBs with TM3 Mode

C373515509

Number of DL TBs with TM4 Mode

C373515510

Number of DL TBs with TM5 Mode

C373515511

Number of DL TBs with TM6 Mode

C373515512

Number of DL TBs with TM7 Mode

C373515591

Number of DL TBs with TM3 RI=1 Mode

C373515592

Number of DL TBs with TM3 RI=2 Mode

10

C373515593

Number of DL TBs with TM4 RI=1 and Tx-Div Mode

11

C373515594

Number of DL TBs with TM4 RI=1 and SM Mode

12

C373515595

Number of DL TBs with TM4 RI=2 Mode

13

C373515596

Number of DL TBs with TM6 RI=1 and Tx-Div Mode

14

C373515597

Number of DL TBs with TM6 RI=1 and SM Mode

11-65
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.12.3 Counter Description


11.12.3.1 C373515506 Number of DL TBs with TM1 Mode
Definition

The counter is used to count the number of transport blocks with TM1
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM1 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM1 MIMO
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM1 MIMO mode in PDSCH channel.

11.12.3.2 C373515507 Number of DL TBs with TM2 Mode


Definition

The counter is used to count the number of transport blocks with TM2
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM2 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM2 MIMO
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM2 MIMO mode in PDSCH channel.

11.12.3.3 C373515508 Number of DL TBs with TM3 Mode


Definition

The counter is used to count the number of transport blocks with TM3
on the downlink.

Sampling Interval

15 min

11-66
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM3 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM3 MIMO
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM3 MIMO mode in PDSCH channel.

11.12.3.4 C373515509 Number of DL TBs with TM4 Mode


Definition

The counter is used to count the number of transport blocks with TM4
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM4 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM4 MIMO
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM4 MIMO mode in PDSCH channel.

11.12.3.5 C373515510 Number of DL TBs with TM5 Mode


Definition

The counter is used to count the number of transport blocks with TM5
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM5 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM5 MIMO
mode in PDSCH channel.
11-67

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM5 MIMO mode in PDSCH channel.

11.12.3.6 C373515511 Number of DL TBs with TM6 Mode


Definition

The counter is used to count the number of transport blocks with TM6
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM6 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM6 MIMO
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM6 MIMO mode in PDSCH channel.

11.12.3.7 C373515512 Number of DL TBs with TM7 Mode


Definition

The counter is used to count the number of transport blocks with TM7
on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM7 MIMO mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM7 MIMO
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM7 MIMO mode in PDSCH channel.

11.12.3.8 C373515591 Number of DL TBs with TM3 RI=1 Mode


Definition

The counter is used to count the number of transport blocks with TM3
RI=1 on the downlink.
11-68

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM3 RI=1 mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM3 RI=1
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM3 RI=1 mode in PDSCH channel.

11.12.3.9 C373515592 Number of DL TBs with TM3 RI=2 Mode


Definition

The counter is used to count the number of transport blocks with TM3
RI=2 on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM3 RI=2 mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM3 RI=2
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM3 RI=2 mode in PDSCH channel.

11.12.3.10 C373515593 Number of DL TBs with TM4 RI=1 and Tx-Div Mode
Definition

The counter is used to count the number of transport blocks with TM4
RI=1 Tx-div on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM4 RI=1 Tx-DIV
mode in PDSCH channel.

11-69
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the number of transport blocks based on TM4 RI=1
Tx-DIV mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM4 RI=1 Tx-DIV mode in PDSCH channel.

11.12.3.11 C373515594 Number of DL TBs with TM4 RI=1 and SM Mode


Definition

The counter is used to count the number of transport blocks with TM4
RI=1 SM on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM4 RI=1 SM


mode in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM4 RI=1
SM mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM4 RI=1 SM mode in PDSCH channel.

11.12.3.12 C373515595 Number of DL TBs with TM4 RI=2 Mode


Definition

The counter is used to count the number of transport blocks with TM4
RI=2 SM on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM4 RI=2 mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM4 RI=2
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM4 RI=2 mode in PDSCH channel.

11-70
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.12.3.13 C373515596 Number of DL TBs with TM6 RI=1 and Tx-Div Mode
Definition

The counter is used to count the number of transport blocks with TM6
RI=1 Tx-div on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM6 RI=1 mode
in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM6 RI=1
mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM6 RI=1 mode in PDSCH channel.

11.12.3.14 C373515597 Number of DL TBs with TM6 RI=1 and SM Mode


Definition

The counter is used to count the number of transport blocks with TM6
RI=1 SM on the downlink.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB schedule a transport block based on TM6 RI=1 mode in
PDSCH channeWhen the eNodeB schedule a transport block based on
TM6 RI=1 SM mode in PDSCH channel.

Explanation

The counter provides the number of transport blocks based on TM6 RI=1
SM mode in PDSCH channel.

Updated

The counter is incremented by 1 When the eNodeB schedule a transport


block based on TM6 RI=1 SM mode in PDSCH channel.

11.13 CCE Aggregation


11.13.1 Flow Charts and Sampling Points
The CCE aggregation level is a search space that the UE monitor. The aggregation levels
defining the search spaces are listed in Table 11-1.

11-71
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Table 11-1 CCE Aggregation Level


Search space
Type

Aggregation level

Size [in CCEs]

UE-specific

12

16

16

16

Common

11.13.2 Counter List


NO.

Counter

Counter Name

Number
1

C373424643

Number of CCE Aggregation Level 1

C373424644

Number of CCE Aggregation Level 2

C373424645

Number of CCE Aggregation Level 4

C373424646

Number of CCE Aggregation Level 8

11.13.3 Counter Description


11.13.3.1 C373424643 Number of CCE Aggregation Level 1
Definition

The counter is used to count the number of CCE aggregation level 1.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 1


for PDCCH.

Explanation

The counter provides the number of CCE aggregation level 1 for PDCCH.

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 1 for PDCCH.

11-72
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.13.3.2 C373424644 Number of CCE Aggregation Level 2


Definition

The counter is used to count the number of CCE aggregation level 2.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 2


for PDCCH.

Explanation

The counter provides the number of CCE aggregation level 2 for PDCCH.

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 2 for PDCCH.

11.13.3.3 C373424645 Number of CCE Aggregation Level 4


Definition

The counter is used to count the number of CCE aggregation level 4.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 4


for PDCCH.

Explanation
Updated

The counter provides the number of CCE aggregation level 4 for PDCCH.
The counter is incremented by 1 when the eNodeB DL scheduler allocates
the CCE aggregation level 4 for PDCCH.

11.13.3.4 C373424646 Number of CCE Aggregation Level 8


Definition

The counter is used to count the number of CCE aggregation level 8.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 8


for PDCCH.

Explanation

The counter provides the number of CCE aggregation level 8 for PDCCH.

11-73
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 8 for PDCCH.

11.14 TA
11.14.1 Flow Charts and Sampling Points
Upon reception of a timing advance command, the UE shall adjust its uplink transmission
timing for PUCCH/PUSCH/SRS. The timing advance command indicates the change of
the uplink timing relative to the current uplink timing as multiples of 16Ts.
In case of random access response, 11-bit timing advance command [8], TA, indicates NTA
values by index values ofTA = 0, 1, 2,..., 1282, where an amount of the time alignment is
given by NTA = TA x 16.

11.14.2 Counter List


NO.

Counter

Counter Name

Number
1

C373556400

Report Times of TA Value in the range of 0 to 1

C373556401

Report Times of TA Value in the range of 2 to 3

C373556402

Report Times of TA Value in the range of 4 to 5

C373556403

Report Times of TA Value in the range of 6 to 7

C373556404

Report Times of TA Value in the range of 8 to 9

C373556405

Report Times of TA Value in the range of 10 to 11

C373556406

Report Times of TA Value in the range of 12 to 13

C373556407

Report Times of TA Value in the range of 14 to 20

C373556408

Report Times of TA Value in the range of 21 to 27

10

C373556409

Report Times of TA Value in the range of 28 to 34

11

C373556410

Report Times of TA Value in the range of 35 to 40

12

C373556411

Report Times of TA Value in the range of 41 to 50

13

C373556412

Report Times of TA Value in the range of 51 to 80

14

C373556413

Report Times of TA Value in the range of 81 to Max

15

C373556414

Maximum of TA Value

11-74
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.14.3 Counter Description


11.14.3.1 C373556400 Report Times of TA Value in the range of 0 to 1
Definition

The counter is used to count the number of Timing Advance values (0 to


1) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 0 and 1.

Explanation

The counter provides the number of TA value which ranges between 0 and
1 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 0 and 1.

11.14.3.2 C373556401 Report Times of TA Value in the range of 2 to 3


Definition

The counter is used to count the number of Timing Advance values (2 to


3) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 2 and 3.

Explanation

The counter provides the number of TA value which ranges between 2 and
3 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 2 and 3.

11.14.3.3 C373556402 Report Times of TA Value in the range of 4 to 5


Definition

The counter is used to count the number of Timing Advance values (4 to


5) transmitted by the eNB to UEs.

Sampling Interval

15 min

11-75
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 4 and 5.

Explanation

The counter provides the number of TA value which ranges between 4 and
5 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 4 and 5.

11.14.3.4 C373556403 Report Times of TA Value in the range of 6 to 7


Definition

The counter is used to count the number of Timing Advance values (6 to


7) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 6 and 7.

Explanation

The counter provides the number of TA value which ranges between 6 and
7 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 6 and 7.

11.14.3.5 C373556404 Report Times of TA Value in the range of 8 to 9


Definition

The counter is used to count the number of Timing Advance values (8 to


9) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 8 and 9.

Explanation

The counter provides the number of TA value which ranges between 8 and
9 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.
11-76

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 8 and 9.

11.14.3.6 C373556405 Report Times of TA Value in the range of 10 to 11


Definition

The counter is used to count the number of Timing Advance values (10 to
11) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 10 and 11.

Explanation

The counter provides the number of TA value which ranges between 10


and 11 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 10 and 11.

11.14.3.7 C373556406 Report Times of TA Value in the range of 12 to 13


Definition

The counter is used to count the number of Timing Advance values (12 to
13) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 12 and 13.

Explanation

The counter provides the number of TA value which ranges between 12


and 13 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 12 and 13.

11.14.3.8 C373556407 Report Times of TA Value in the range of 14 to 20


Definition

The counter is used to count the number of Timing Advance values (14 to
20) transmitted by the eNB to UEs.
11-77

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 14 and 20.

Explanation

The counter provides the number of TA value which ranges between 14


and 20 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 14 and 20.

11.14.3.9 C373556408 Report Times of TA Value in the range of 21 to 27


Definition

The counter is used to count the number of Timing Advance values (21 to
27) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 21 and 27.

Explanation

The counter provides the number of TA value which ranges between 21


and 27 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 21 and 27.

11.14.3.10 C373556409 Report Times of TA Value in the range of 28 to 34


Definition

The counter is used to count the number of Timing Advance values (28 to
34) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 28 and 34.

11-78
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Explanation

The counter provides the number of TA value which ranges between 28


and 34 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 28 and 34.

11.14.3.11 C373556410 Report Times of TA Value in the range of 35 to 40


Definition

The counter is used to count the number of Timing Advance values (35 to
40) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 35 and 40.

Explanation

The counter provides the number of TA value which ranges between 35


and 40 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 35 and 40.

11.14.3.12 C373556411 Report Times of TA Value in the range of 41 to 50


Definition

The counter is used to count the number of Timing Advance values (41 to
50) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 41 and 50.

Explanation

The counter provides the number of TA value which ranges between 41


and 50 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 41 and 50.

11-79
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.14.3.13 C373556412 Report Times of TA Value in the range of 51 to 80


Definition

The counter is used to count the number of Timing Advance values (51 to
80) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 51 and 80.

Explanation

The counter provides the number of TA value which ranges between 51


and 80 in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 51 and 80.

11.14.3.14 C373556413 Report Times of TA Value in the range of 81 to Max


Definition

The counter is used to count the number of Timing Advance values (81 to
MAX) transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE and the TA absolute
value therein ranges between 81 and Max.

Explanation

The counter provides the number of TA value which ranges between 81 and
MAX in message2 transmitted by eNodeB to UEs. The value unit is 16Ts.

Updated

The counter is incremented by 1 when the eNodeB sends the message2 to


the UE and the TA absolute value therein ranges between 81 and Max.

11.14.3.15 C373556414 Maximum of TA Value


Definition

The counter is used to count the maximum of Timing Advance values


transmitted by the eNB to UEs.

Sampling Interval

15 min

Counter Type

Maximum

Unit

16 Ts

11-80
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

When the eNodeB sends the message2 to the UE

Explanation

When the eNodeB sends the message2 to the UE, the TA value is includes
in the message2. The counter provides the maximum of TA value in
message2.

Updated

The counter is replaced with the current value when the current TA value is
larger than the prior at sampling point.

11.15 Msg2
11.15.1 Flow Charts and Sampling Points
No chart.

11.15.2 Counter List


NO.

Counter

Counter Name

Number
1

C373444755

Number of Successful Msg3 Checked by eNodeB

C373444756

Number of Lossed Msg3 Checked by eNodeB

C373444759

Number of Sended Msg2 by ENB

11.15.3 Counter Description


11.15.3.1 C373444755 Number of Successful Msg3 Checked by eNodeB
Definition

The counter is used to count the number of successful msg3 checked


by eNodeB.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB checks the msg3 successfully.

Explanation

The counter provides the number of successful msg3 checked by eNodeB.

Updated

The counter is incremented by 1 when the eNodeB checks the msg3


successfully.

11-81
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.15.3.2 C373444756 Number of Lossed Msg3 Checked by eNodeB


Definition

The counter is used to count the number of lossed msg3 checked by


eNodeB.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB checks the msg3 unsuccessfully.

Explanation

The counter provides the number of lossed msg3 checked by eNodeB.

Updated

The counter is incremented by 1 when the eNodeB checks the msg3


unsuccessfully.

11.15.3.3 C373444759 Number of Sended Msg2 by ENB


Definition

The counter is used to count the number of the message2 transmitted


by eNodeB.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the messag2 to the UE.

Explanation

The counter provides the number of the message2 transmitted by eNodeB


to UE.

Updated

The counter is incremented by 1 when the eNodeB sends the messag2 to


the UE.

11.16 NI
11.16.1 Flow Charts and Sampling Points
No chart.

11.16.2 Counter List


NO.

Counter

Counter Name

Number
1

C373586700

RB0 Maximum NI
11-82

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

NO.

Counter

Counter Name

Number
2

C373586701

RB1 Maximum NI

C373586702

RB2 Maximum NI

C373586703

RB3 Maximum NI

C373586704

RB4 Maximum NI

C373586705

RB5 Maximum NI

C373586706

RB6 Maximum NI

C373586707

RB7 Maximum NI

C373586708

RB8 Maximum NI

10

C373586709

RB9 Maximum NI

11

C373586710

RB10 Maximum NI

12

C373586711

RB11 Maximum NI

13

C373586712

RB12 Maximum NI

14

C373586713

RB13 Maximum NI

15

C373586714

RB14 Maximum NI

16

C373586715

RB15 Maximum NI

17

C373586716

RB16 Maximum NI

18

C373586717

RB17 Maximum NI

19

C373586718

RB18 Maximum NI

20

C373586719

RB19 Maximum NI

21

C373586720

RB20 Maximum NI

22

C373586721

RB21 Maximum NI

23

C373586722

RB22 Maximum NI

24

C373586723

RB23 Maximum NI

25

C373586724

RB24 Maximum NI

26

C373586725

RB25 Maximum NI

27

C373586726

RB26 Maximum NI

28

C373586727

RB27 Maximum NI

29

C373586728

RB28 Maximum NI

30

C373586729

RB29 Maximum NI

31

C373586730

RB30 Maximum NI

32

C373586731

RB31 Maximum NI

33

C373586732

RB32 Maximum NI

11-83
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
34

C373586733

RB33 Maximum NI

35

C373586734

RB34 Maximum NI

36

C373586735

RB35 Maximum NI

37

C373586736

RB36 Maximum NI

38

C373586737

RB37 Maximum NI

39

C373586738

RB38 Maximum NI

40

C373586739

RB39 Maximum NI

41

C373586740

RB40 Maximum NI

42

C373586741

RB41 Maximum NI

43

C373586742

RB42 Maximum NI

44

C373586743

RB43 Maximum NI

45

C373586744

RB44 Maximum NI

46

C373586745

RB45 Maximum NI

47

C373586746

RB46 Maximum NI

48

C373586747

RB47 Maximum NI

49

C373586748

RB48 Maximum NI

50

C373586749

RB49 Maximum NI

51

C373586750

RB50 Maximum NI

52

C373586751

RB51 Maximum NI

53

C373586752

RB52 Maximum NI

54

C373586753

RB53 Maximum NI

55

C373586754

RB54 Maximum NI

56

C373586755

RB55 Maximum NI

57

C373586756

RB56 Maximum NI

58

C373586757

RB57 Maximum NI

59

C373586758

RB58 Maximum NI

60

C373586759

RB59 Maximum NI

61

C373586760

RB60 Maximum NI

62

C373586761

RB61 Maximum NI

63

C373586762

RB62 Maximum NI

64

C373586763

RB63 Maximum NI

65

C373586764

RB64 Maximum NI

11-84
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

NO.

Counter

Counter Name

Number
66

C373586765

RB65 Maximum NI

67

C373586766

RB66 Maximum NI

68

C373586767

RB67 Maximum NI

69

C373586768

RB68 Maximum NI

70

C373586769

RB69 Maximum NI

71

C373586770

RB70 Maximum NI

72

C373586771

RB71 Maximum NI

73

C373586772

RB72 Maximum NI

74

C373586773

RB73 Maximum NI

75

C373586774

RB74 Maximum NI

76

C373586775

RB75 Maximum NI

77

C373586776

RB76 Maximum NI

78

C373586777

RB77 Maximum NI

79

C373586778

RB78 Maximum NI

80

C373586779

RB79 Maximum NI

81

C373586780

RB80 Maximum NI

82

C373586781

RB81 Maximum NI

83

C373586782

RB82 Maximum NI

84

C373586783

RB83 Maximum NI

85

C373586784

RB84 Maximum NI

86

C373586785

RB85 Maximum NI

87

C373586786

RB86 Maximum NI

88

C373586787

RB87 Maximum NI

89

C373586788

RB88 Maximum NI

90

C373586789

RB89 Maximum NI

91

C373586790

RB90 Maximum NI

92

C373586791

RB91 Maximum NI

93

C373586792

RB92 Maximum NI

94

C373586793

RB93 Maximum NI

95

C373586794

RB94 Maximum NI

96

C373586795

RB95 Maximum NI

97

C373586796

RB96 Maximum NI

11-85
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
98

C373586797

RB97 Maximum NI

99

C373586798

RB98 Maximum NI

100

C373586799

RB99 Maximum NI

101

C373586800

RB0 Average NI

102

C373586801

RB1 Average NI

103

C373586802

RB2 Average NI

104

C373586803

RB3 Average NI

105

C373586804

RB4 Average NI

106

C373586805

RB5 Average NI

107

C373586806

RB6 Average NI

108

C373586807

RB7 Average NI

109

C373586808

RB8 Average NI

110

C373586809

RB9 Average NI

111

C373586810

RB10 Average NI

112

C373586811

RB11 Average NI

113

C373586812

RB12 Average NI

114

C373586813

RB13 Average NI

115

C373586814

RB14 Average NI

116

C373586815

RB15 Average NI

117

C373586816

RB16 Average NI

118

C373586817

RB17 Average NI

119

C373586818

RB18 Average NI

120

C373586819

RB19 Average NI

121

C373586820

RB20 Average NI

122

C373586821

RB21 Average NI

123

C373586822

RB22 Average NI

124

C373586823

RB23 Average NI

125

C373586824

RB24 Average NI

126

C373586825

RB25 Average NI

127

C373586826

RB26 Average NI

128

C373586827

RB27 Average NI

129

C373586828

RB28 Average NI

11-86
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

NO.

Counter

Counter Name

Number
130

C373586829

RB29 Average NI

131

C373586830

RB30 Average NI

132

C373586831

RB31 Average NI

133

C373586832

RB32 Average NI

134

C373586833

RB33 Average NI

135

C373586834

RB34 Average NI

136

C373586835

RB35 Average NI

137

C373586836

RB36 Average NI

138

C373586837

RB37 Average NI

139

C373586838

RB38 Average NI

140

C373586839

RB39 Average NI

141

C373586840

RB40 Average NI

142

C373586841

RB41 Average NI

143

C373586842

RB42 Average NI

144

C373586843

RB43 Average NI

145

C373586844

RB44 Average NI

146

C373586845

RB45 Average NI

147

C373586846

RB46 Average NI

148

C373586847

RB47 Average NI

149

C373586848

RB48 Average NI

150

C373586849

RB49 Average NI

151

C373586850

RB50 Average NI

152

C373586851

RB51 Average NI

153

C373586852

RB52 Average NI

154

C373586853

RB53 Average NI

155

C373586854

RB54 Average NI

156

C373586855

RB55 Average NI

157

C373586856

RB56 Average NI

158

C373586857

RB57 Average NI

159

C373586858

RB58 Average NI

160

C373586859

RB59 Average NI

161

C373586860

RB60 Average NI

11-87
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
162

C373586861

RB61 Average NI

163

C373586862

RB62 Average NI

164

C373586863

RB63 Average NI

165

C373586864

RB64 Average NI

166

C373586865

RB65 Average NI

167

C373586866

RB66 Average NI

168

C373586867

RB67 Average NI

169

C373586868

RB68 Average NI

170

C373586869

RB69 Average NI

171

C373586870

RB70 Average NI

172

C373586871

RB71 Average NI

173

C373586872

RB72 Average NI

174

C373586873

RB73 Average NI

175

C373586874

RB74 Average NI

176

C373586875

RB75 Average NI

177

C373586876

RB76 Average NI

178

C373586877

RB77 Average NI

179

C373586878

RB78 Average NI

180

C373586879

RB79 Average NI

181

C373586880

RB80 Average NI

182

C373586881

RB81 Average NI

183

C373586882

RB82 Average NI

184

C373586883

RB83 Average NI

185

C373586884

RB84 Average NI

186

C373586885

RB85 Average NI

187

C373586886

RB86 Average NI

188

C373586887

RB87 Average NI

189

C373586888

RB88 Average NI

190

C373586889

RB89 Average NI

191

C373586890

RB90 Average NI

192

C373586891

RB91 Average NI

193

C373586892

RB92 Average NI

11-88
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

NO.

Counter

Counter Name

Number
194

C373586893

RB93 Average NI

195

C373586894

RB94 Average NI

196

C373586895

RB95 Average NI

197

C373586896

RB96 Average NI

198

C373586897

RB97 Average NI

199

C373586898

RB98 Average NI

200

C373586899

RB99 Average NI

11.16.3 Counter Description


11.16.3.1 C373586700 RB0 Maximum NI
Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.2 C373586701 RB1 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.


11-89

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.3 C373586702 RB2 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.4 C373586703 RB3 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11-90
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.5 C373586704 RB4 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.6 C373586705 RB5 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.7 C373586706 RB6 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-91
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.8 C373586707 RB7 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.9 C373586708 RB8 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-92

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.10 C373586709 RB9 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.11 C373586710 RB10 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.12 C373586711 RB11 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-93
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.13 C373586712 RB12 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.14 C373586713 RB13 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-94

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.15 C373586714 RB14 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.16 C373586715 RB15 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.17 C373586716 RB16 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-95
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.18 C373586717 RB17 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.19 C373586718 RB18 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-96

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.20 C373586719 RB19 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.21 C373586720 RB20 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.22 C373586721 RB21 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-97
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.23 C373586722 RB22 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.24 C373586723 RB23 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-98

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.25 C373586724 RB24 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.26 C373586725 RB25 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.27 C373586726 RB26 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-99
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.28 C373586727 RB27 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.29 C373586728 RB28 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-100

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.30 C373586729 RB29 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.31 C373586730 RB30 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.32 C373586731 RB31 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-101
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.33 C373586732 RB32 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.34 C373586733 RB33 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-102

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.35 C373586734 RB34 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.36 C373586735 RB35 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.37 C373586736 RB36 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-103
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.38 C373586737 RB37 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.39 C373586738 RB38 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-104

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.40 C373586739 RB39 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.41 C373586740 RB40 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.42 C373586741 RB41 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-105
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.43 C373586742 RB42 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.44 C373586743 RB43 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-106

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.45 C373586744 RB44 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.46 C373586745 RB45 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.47 C373586746 RB46 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-107
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.48 C373586747 RB47 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.49 C373586748 RB48 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-108

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.50 C373586749 RB49 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.51 C373586750 RB50 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.52 C373586751 RB51 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-109
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.53 C373586752 RB52 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.54 C373586753 RB53 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-110

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.55 C373586754 RB54 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.56 C373586755 RB55 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.57 C373586756 RB56 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-111
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.58 C373586757 RB57 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.59 C373586758 RB58 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-112

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.60 C373586759 RB59 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.61 C373586760 RB60 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.62 C373586761 RB61 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-113
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.63 C373586762 RB62 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.64 C373586763 RB63 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-114

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.65 C373586764 RB64 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.66 C373586765 RB65 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.67 C373586766 RB66 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-115
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.68 C373586767 RB67 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.69 C373586768 RB68 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-116

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.70 C373586769 RB69 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.71 C373586770 RB70 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.72 C373586771 RB71 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-117
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.73 C373586772 RB72 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.74 C373586773 RB73 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-118

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.75 C373586774 RB74 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.76 C373586775 RB75 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.77 C373586776 RB76 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-119
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.78 C373586777 RB77 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.79 C373586778 RB78 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-120

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.80 C373586779 RB79 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.81 C373586780 RB80 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.82 C373586781 RB81 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-121
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.83 C373586782 RB82 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.84 C373586783 RB83 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-122

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.85 C373586784 RB84 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.86 C373586785 RB85 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.87 C373586786 RB86 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-123
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.88 C373586787 RB87 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.89 C373586788 RB88 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-124

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.90 C373586789 RB89 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.91 C373586790 RB90 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.92 C373586791 RB91 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-125
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.93 C373586792 RB92 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.94 C373586793 RB93 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-126

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.95 C373586794 RB94 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.96 C373586795 RB95 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.97 C373586796 RB96 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

11-127
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.98 C373586797 RB97 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.99 C373586798 RB98 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.
11-128

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.100 C373586799 RB99 Maximum NI


Definition

The counter is used to count the maximum NI of RBx(x=0,1,,99) on


the uplink.

Sampling Interval

1 ms

Counter Type

Maximum

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99). Take the maximum NI of RBx(x=0,1,,99) as
the sampling value.

Updated

The counter is replaced with the current value when the current NI of
RBx(x=0,1,,99) is larger than the prior at sampling point.

11.16.3.101 C373586800 RB0 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.102 C373586801 RB1 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-129
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.103 C373586802 RB2 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.104 C373586803 RB3 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-130

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.105 C373586804 RB4 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.106 C373586805 RB5 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.107 C373586806 RB6 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-131
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.108 C373586807 RB7 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.109 C373586808 RB8 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-132

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.110 C373586809 RB9 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.111 C373586810 RB10 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.112 C373586811 RB11 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-133
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.113 C373586812 RB12 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.114 C373586813 RB13 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-134

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.115 C373586814 RB14 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.116 C373586815 RB15 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.117 C373586816 RB16 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-135
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.118 C373586817 RB17 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.119 C373586818 RB18 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-136

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.120 C373586819 RB19 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.121 C373586820 RB20 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.122 C373586821 RB21 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-137
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.123 C373586822 RB22 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.124 C373586823 RB23 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-138

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.125 C373586824 RB24 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.126 C373586825 RB25 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.127 C373586826 RB26 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-139
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.128 C373586827 RB27 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.129 C373586828 RB28 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-140

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.130 C373586829 RB29 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.131 C373586830 RB30 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.132 C373586831 RB31 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-141
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.133 C373586832 RB32 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.134 C373586833 RB33 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-142

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.135 C373586834 RB34 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.136 C373586835 RB35 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.137 C373586836 RB36 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-143
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.138 C373586837 RB37 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.139 C373586838 RB38 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-144

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.140 C373586839 RB39 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.141 C373586840 RB40 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.142 C373586841 RB41 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-145
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.143 C373586842 RB42 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.144 C373586843 RB43 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-146

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.145 C373586844 RB44 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.146 C373586845 RB45 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.147 C373586846 RB46 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-147
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.148 C373586847 RB47 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.149 C373586848 RB48 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-148

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.150 C373586849 RB49 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.151 C373586850 RB50 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.152 C373586851 RB51 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-149
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.153 C373586852 RB52 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.154 C373586853 RB53 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-150

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.155 C373586854 RB54 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.156 C373586855 RB55 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.157 C373586856 RB56 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-151
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.158 C373586857 RB57 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.159 C373586858 RB58 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-152

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.160 C373586859 RB59 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.161 C373586860 RB60 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.162 C373586861 RB61 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-153
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.163 C373586862 RB62 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.164 C373586863 RB63 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-154

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.165 C373586864 RB64 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.166 C373586865 RB65 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.167 C373586866 RB66 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-155
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.168 C373586867 RB67 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.169 C373586868 RB68 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-156

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.170 C373586869 RB69 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.171 C373586870 RB70 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.172 C373586871 RB71 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-157
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.173 C373586872 RB72 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.174 C373586873 RB73 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-158

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.175 C373586874 RB74 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.176 C373586875 RB75 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.177 C373586876 RB76 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-159
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.178 C373586877 RB77 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.179 C373586878 RB78 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-160

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.180 C373586879 RB79 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.181 C373586880 RB80 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.182 C373586881 RB81 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-161
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.183 C373586882 RB82 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.184 C373586883 RB83 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-162

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.185 C373586884 RB84 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.186 C373586885 RB85 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.187 C373586886 RB86 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-163
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.188 C373586887 RB87 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.189 C373586888 RB88 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-164

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.190 C373586889 RB89 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.191 C373586890 RB90 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.192 C373586891 RB91 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-165
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.193 C373586892 RB92 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.194 C373586893 RB93 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-166

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.195 C373586894 RB94 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.196 C373586895 RB95 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.197 C373586896 RB96 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

11-167
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.198 C373586897 RB97 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.16.3.199 C373586898 RB98 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.
11-168

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.16.3.200 C373586899 RB99 Average NI


Definition

The counter is used to count the average NI of RBx(x=0,1,,99) on the


uplink.

Sampling Interval

1 ms

Counter Type

Average

Unit

dBm

Measurement Object

Cell

Sampling Point

When the eNodeB receives the UL data from the UE.

Explanation

When the eNodeB receives the UL data from the UE, PHY detect the
NI of RBx(x=0,1,,99).Take the average NI of RBx(x=0,1,,99) as the
sampling value.

Updated

The counter is updated by accumulating all the sampling NI of


RBx(x=0,1,,99), and then dividing the sum by the measurement period.

11.17 ICIC
11.17.1 Flow Charts and Sampling Points
No chart.

11.17.2 Counter List


NO.

Counter

Counter Name

Number
1

C373566450

Average Number of Cell Edge Users

C373566451

Average Throughput of DL PHY on Edge Area

C373566452

Average Throughput of UL PHY on Edge Area

C373566453

PRB Number of PDSCH for Cell Edge Users

C373566454

PRB Number of PUSCH for Cell Edge Users

C373566455

Number of CCE Aggregation Level 1 on Edge Area

C373566456

Number of CCE Aggregation Level 2 on Edge Area

C373566457

Number of CCE Aggregation Level 4 on Edge Area

C373566458

Number of CCE Aggregation Level 8 on Edge Area

10

C373566459

Number of DL TBs on Edge Area

11

C373566460

Error Number of DL TBs on Edge Area

12

C373566461

Number of UL TBs on Edge Area


11-169

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

NO.

Counter

Counter Name

Number
13

C373566462

Error Number of UL TBs on Edge Area

14

C373566463

Percentage of RNTP beyond the Threshold in the range of 0 to 5

15

C373566464

Percentage of RNTP beyond the Threshold in the range of 6 to 10

16

C373566465

Percentage of RNTP beyond the Threshold in the range of 11 to 15

17

C373566466

Percentage of RNTP beyond the Threshold in the range of 16 to 20

18

C373566467

Percentage of RNTP beyond the Threshold in the range of 21 to 25

19

C373566468

Percentage of RNTP beyond the Threshold in the range of 26 to 30

20

C373566469

Percentage of RNTP beyond the Threshold in the range of 31 to 35

21

C373566470

Percentage of RNTP beyond the Threshold in the range of 36 to 40

22

C373566471

Percentage of RNTP beyond the Threshold in the range of 41 to 45

23

C373566472

Percentage of RNTP beyond the Threshold in the range of 46 to 50

24

C373566473

Percentage of RNTP beyond the Threshold in the range of 51 to 55

25

C373566474

Percentage of RNTP beyond the Threshold in the range of 56 to 60

26

C373566475

Percentage of RNTP beyond the Threshold in the range of 61 to 65

27

C373566476

Percentage of RNTP beyond the Threshold in the range of 66 to 70

28

C373566477

Percentage of RNTP beyond the Threshold in the range of 71 to 75

29

C373566478

Percentage of RNTP beyond the Threshold in the range of 76 to 80

30

C373566479

Percentage of RNTP beyond the Threshold in the range of 81 to 85

31

C373566480

Percentage of RNTP beyond the Threshold in the range of 86 to 90

32

C373566481

Percentage of RNTP beyond the Threshold in the range of 91 to 95

33

C373566482

Percentage of RNTP beyond the Threshold in the range of 96 to 100

34

C373566483

Percentage of HII in the range of 0 to 5

35

C373566484

Percentage of HII in the range of 6 to 10

36

C373566485

Percentage of HII in the range of 11 to 15

37

C373566486

Percentage of HII in the range of 16 to 20

38

C373566487

Percentage of HII in the range of 21 to 25

39

C373566488

Percentage of HII in the range of 26 to 30

40

C373566489

Percentage of HII in the range of 31 to 35

41

C373566490

Percentage of HII in the range of 36 to 40

42

C373566491

Percentage of HII in the range of 41 to 45

43

C373566492

Percentage of HII in the range of 46 to 50

44

C373566493

Percentage of HII in the range of 51 to 55

11-170
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

NO.

Counter

Counter Name

Number
45

C373566494

Percentage of HII in the range of 56 to 60

46

C373566495

Percentage of HII in the range of 61 to 65

47

C373566496

Percentage of HII in the range of 66 to 70

48

C373566497

Percentage of HII in the range of 71 to 75

49

C373566498

Percentage of HII in the range of 76 to 80

50

C373566499

Percentage of HII in the range of 81 to 85

51

C373566500

Percentage of HII in the range of 86 to 90

52

C373566501

Percentage of HII in the range of 91 to 95

53

C373566502

Percentage of HII in the range of 96 to 100

54

C373566503

HII exceeds a threshold Time

11.17.3 Counter Description


11.17.3.1 C373566450 Average Number of Cell Edge Users
Definition

The counter is used to count the average number of cell edge user.

Sampling Interval

100 ms

Counter Type

Average

Unit

Unit

Measurement Object

Cell

Sampling Point

The eNodeB sheduler collects the number of UEs which is "active state" at
sampling time in cell edge.

Explanation

The active state indicates the user is always active if the short DRX is
configured to UE. And if the long DRX is configured to UE, the user
is active when having traffic and DRX high level.Otherwise the user is
inactive. The counter provides the average value of all sampling point
in the measurement period.

Updated

The counter is updated by accumulating all the sample active state UEs,
and then dividing the sum by the measurement period.

11.17.3.2 C373566451 Average Throughput of DL PHY on Edge Area


Definition

The counter is used to count the average cell edge throughput on the
downlink.

11-171
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer sends data to the air in cell edge.

Explanation

Downlink PHY Traffic on the Sampling Point = the size of TBs.That


includes retransmission TBs.The counter takes the average value of all
sampling granularities in the statistical period.

Updated

The counter is updated by accumulating all the sampling physical layer


volume, and then dividing the sum by the measurement period.

11.17.3.3 C373566452 Average Throughput of UL PHY on Edge Area


Definition

The counter is used to count the average cell edge throughput on the
uplink.

Sampling Interval

1s

Counter Type

Average

Unit

Kbps

Measurement Object

Cell

Sampling Point

When the eNodeB physical layer receives data from the air in cell edge.

Explanation

Uplink PHY traffic on the sampling point = the size of TBs. That includes
retransmission TBs. The counter takes the average value of all sampling
granularities in the statistical period.

Updated

The counter is updated by accumulating all the sampling physical layer


volume, and then dividing the sum by the measurement period.

11.17.3.4 C373566453 PRB Number of PDSCH for Cell Edge Users


Definition

The counter is used to count the number of PDSCH PRB in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB downlink scheduler schedule TB and assign the PRB in


PDSCH channe in cell edge.

11-172
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Explanation

It is all available PRBs that eNodeB have assigned for PDSCH on the
downlink in cell edge.

Updated

The counter is increased by the PRB number used for PDSCH channel at
sampling point.

11.17.3.5 C373566454 PRB Number of PUSCH for Cell Edge Users


Definition

The counter is used to count the number of PUSCH PRB in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB uplink scheduler schedule TB and assign the PRB in


PUSCH channel in cell edge.

Explanation

It is all available PRBs that eNodeB have assigned for PUSCH on the
uplink in cell edge.

Updated

The counter is increased by the assigned PRB number for PUSCH at


sampling point.

11.17.3.6 C373566455 Number of CCE Aggregation Level 1 on Edge Area


Definition

The counter is used to count the number of CCE aggregation level 1


in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 1 for
PDCCH in cell edge.

Explanation

The counter provides the number of CCE aggregation level 1 for PDCCH
in cell edge.

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 1 for PDCCH in cell edge.

11-173
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.17.3.7 C373566456 Number of CCE Aggregation Level 2 on Edge Area


Definition

The counter is used to count the number of CCE aggregation level 2


in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 2 for
PDCCH in cell edge.

Explanation

The counter provides the number of CCE aggregation level 2 for PDCCH
in cell edge.

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 2 for PDCCH in cell edge.

11.17.3.8 C373566457 Number of CCE Aggregation Level 4 on Edge Area


Definition

The counter is used to count the number of CCE aggregation level 4


in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 4 for
PDCCH in cell edge.

Explanation

The counter provides the number of CCE aggregation level 4 for PDCCH
in cell edge.

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 4 for PDCCH in cell edge.

11.17.3.9 C373566458 Number of CCE Aggregation Level 8 on Edge Area


Definition

The counter is used to count the number of CCE aggregation level 8


in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

11-174
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Measurement Object

Cell

Sampling Point

When the eNodeB DL scheduler allocates the CCE aggregation level 8 for
PDCCH in cell edge.

Explanation

The counter provides the number of CCE aggregation level 8 for PDCCH
in cell edge.

Updated

The counter is incremented by 1 when the eNodeB DL scheduler allocates


the CCE aggregation level 8 for PDCCH in cell edge.

11.17.3.10 C373566459 Number of DL TBs on Edge Area


Definition

The counter is used to count the total number of TBs transmitted on the
downlink in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty reception of TB


by UE in cell edge.

Explanation

After the eNodeB send a transport block to the UE, it will receive HARQ
feedback information from the UE. If the HARQ feedback is NACK or DTX
in cell edge, it is added to the counter.

Updated

The counter is incremented by 1 when eNB receives a NACK or DTX


HARQ feedback in cell edge.

11.17.3.11 C373566460 Error Number of DL TBs on Edge Area


Definition

The counter is used to count the number of faulty TBs transmitted on the
downlink in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for DL data in cell edge.

Explanation

After the eNodeB send a transport block to the UE, it will receive HARQ
feedback information from the UE. No matter the HARQ feedback is
ACK,NACK or DTX in cell edge, it is added to the counter.

11-175
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is incremented by 1 when eNB schedules one TB for DL data


in cell edge.

11.17.3.12 C373566461 Number of UL TBs on Edge Area


Definition

The counter is used to count the total number of TBs transmitted on the
uplink in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB receives a NACK or DTX indicating a faulty reception of TB


by UE in cell edge.

Explanation

After the eNodeB received a transport block from the UE, it will reply
HARQ feedback information to the UE. If the HARQ feedback is NACK or
DTX in cell edge, it is added to the counter.

Updated

The counter is incremented by 1 when eNB detects a CRC error TB in


cell edge.

11.17.3.13 C373566462 Error Number of UL TBs on Edge Area


Definition

The counter is used to count the number of faulty TBs transmitted on the
uplink in cell edge.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When eNodeB schedules a TB for UL data in cell edge.

Explanation

After the eNodeB received a transport block from the UE, it will reply
HARQ feedback information to the UE. No matter the HARQ feedback is
ACK,NACK or DTX in cell edge, it is added to the counter.

Updated

The counter is incremented by 1 when eNB schedules one TB for UL data


in cell edge.

11-176
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.17.3.14 C373566463 Percentage of RNTP beyond the Threshold in the range of 0 to 5


Definition

The counter is used to count the number of the RNTP percentage (0%
to 5%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(0% to 5%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 0% to 5%, the


counter is incremented by 1.

11.17.3.15 C373566464 Percentage of RNTP beyond the Threshold in the range of 6


to 10
Definition

The counter is used to count the number of the RNTP percentage (6% to
10%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(6% to 10%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 6% to 10%,


the counter is incremented by 1.

11-177
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.17.3.16 C373566465 Percentage of RNTP beyond the Threshold in the range of


11 to 15
Definition

The counter is used to count the number of the RNTP percentage (11% to
15%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(11% to 15%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 11% to 15%,


the counter is incremented by 1.

11.17.3.17 C373566466 Percentage of RNTP beyond the Threshold in the range of


16 to 20
Definition

The counter is used to count the number of the RNTP percentage (16% to
20%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(16% to 20%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 16% to 20%,


the counter is incremented by 1.

11-178
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.17.3.18 C373566467 Percentage of RNTP beyond the Threshold in the range of


21 to 25
Definition

The counter is used to count the number of the RNTP percentage (21% to
25%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(21% to 25%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 21% to 25%,


the counter is incremented by 1.

11.17.3.19 C373566468 Percentage of RNTP beyond the Threshold in the range of


26 to 30
Definition

The counter is used to count the number of the RNTP percentage (26% to
30%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(26% to 30%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 26% to 30%,


the counter is incremented by 1.

11-179
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.17.3.20 C373566469 Percentage of RNTP beyond the Threshold in the range of


31 to 35
Definition

The counter is used to count the number of the RNTP percentage (31% to
35%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(31% to 35%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 31% to 35%,


the counter is incremented by 1.

11.17.3.21 C373566470 Percentage of RNTP beyond the Threshold in the range of


36 to 40
Definition

The counter is used to count the number of the RNTP percentage (36% to
40%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(36% to 40%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 36% to 40%,


the counter is incremented by 1.

11-180
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.17.3.22 C373566471 Percentage of RNTP beyond the Threshold in the range of


41 to 45
Definition

The counter is used to count the number of the RNTP percentage (41% to
45%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(41% to 45%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 41% to 45%,


the counter is incremented by 1.

11.17.3.23 C373566472 Percentage of RNTP beyond the Threshold in the range of


46 to 50
Definition

The counter is used to count the number of the RNTP percentage (46% to
50%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(46% to 50%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 46% to 50%,


the counter is incremented by 1.

11-181
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.17.3.24 C373566473 Percentage of RNTP beyond the Threshold in the range of


51 to 55
Definition

The counter is used to count the number of the RNTP percentage (51% to
55%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(51% to 55%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 51% to 55%,


the counter is incremented by 1.

11.17.3.25 C373566474 Percentage of RNTP beyond the Threshold in the range of


56 to 60
Definition

The counter is used to count the number of the RNTP percentage (56% to
60%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(56% to 60%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 56% to 60%,


the counter is incremented by 1.

11-182
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.17.3.26 C373566475 Percentage of RNTP beyond the Threshold in the range of


61 to 65
Definition

The counter is used to count the number of the RNTP percentage (61% to
65%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(61% to 65%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 61% to 65%,


the counter is incremented by 1.

11.17.3.27 C373566476 Percentage of RNTP beyond the Threshold in the range of


66 to 70
Definition

The counter is used to count the number of the RNTP percentage (66% to
70%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(66% to 70%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 66% to 70%,


the counter is incremented by 1.

11-183
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.17.3.28 C373566477 Percentage of RNTP beyond the Threshold in the range of


71 to 75
Definition

The counter is used to count the number of the RNTP percentage (71% to
75%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(71% to 75%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 71% to 75%,


the counter is incremented by 1.

11.17.3.29 C373566478 Percentage of RNTP beyond the Threshold in the range of


76 to 80
Definition

The counter is used to count the number of the RNTP percentage (76% to
80%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(76% to 80%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 76% to 80%,


the counter is incremented by 1.

11-184
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.17.3.30 C373566479 Percentage of RNTP beyond the Threshold in the range of


81 to 85
Definition

The counter is used to count the number of the RNTP percentage (81% to
85%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(81% to 85%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 81% to 85%,


the counter is incremented by 1.

11.17.3.31 C373566480 Percentage of RNTP beyond the Threshold in the range of


86 to 90
Definition

The counter is used to count the number of the RNTP percentage (86% to
90%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(86% to 90%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 86% to 90%,


the counter is incremented by 1.

11-185
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

11.17.3.32 C373566481 Percentage of RNTP beyond the Threshold in the range of


91 to 95
Definition

The counter is used to count the number of the RNTP percentage (91% to
95%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(91% to 95%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 91% to 95%,


the counter is incremented by 1.

11.17.3.33 C373566482 Percentage of RNTP beyond the Threshold in the range of


96 to 100
Definition

The counter is used to count the number of the RNTP percentage (96% to
100%) that exceeds the threshold.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the Relative Narrowband Tx Power (RNTP) IE is received in the LOAD


INFORMATION message, it indicates, per PRB, whether downlink
transmission power is lower than the value indicated by the RNTP
Threshold IE. The counter provides the number of the RNTP percentage
(96% to 100%) that exceeds the threshold.

Updated

When the being 1 percentage of RNTP bitmap is in range of 96% to 100%,


the counter is incremented by 1.

11-186
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.17.3.34 C373566483 Percentage of HII in the range of 0 to 5


Definition

The counter is used to count the number of the HII percentage (0% to 5%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (0% to 5%).

Updated

When the being 1 percentage of HII bitmap is in range of 0% to 5%, the


counter is incremented by 1.

11.17.3.35 C373566484 Percentage of HII in the range of 6 to 10


Definition

The counter is used to count the number of the HII percentage (6% to 10%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (6% to
10%).

Updated

When the being 1 percentage of HII bitmap is in range of 6% to 10%, the


counter is incremented by 1.

11.17.3.36 C373566485 Percentage of HII in the range of 11 to 15


Definition

The counter is used to count the number of the HII percentage (11%
to 15%).
11-187

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (11%
to 15%).

Updated

When the being 1 percentage of HII bitmap is in range of 11% to 15%, the
counter is incremented by 1.

11.17.3.37 C373566486 Percentage of HII in the range of 16 to 20


Definition

The counter is used to count the number of the HII percentage (16% to
20%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (16% to
20%).

Updated

When the being 1 percentage of HII bitmap is in range of 16% to 20%, the
counter is incremented by 1.

11.17.3.38 C373566487 Percentage of HII in the range of 21 to 25


Definition

The counter is used to count the number of the HII percentage (21% to
25%).
11-188

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (21% to
25%).

Updated

When the being 1 percentage of HII bitmap is in range of 21% to 25%, the
counter is incremented by 1.

11.17.3.39 C373566488 Percentage of HII in the range of 26 to 30


Definition

The counter is used to count the number of the HII percentage (26% to
30%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (26% to
30%).

Updated

When the being 1 percentage of HII bitmap is in range of 26% to 30%, the
counter is incremented by 1.

11.17.3.40 C373566489 Percentage of HII in the range of 31 to 35


Definition

The counter is used to count the number of the HII percentage (31% to
35%).
11-189

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (31% to
35%).

Updated

When the being 1 percentage of HII bitmap is in range of 31% to 35%, the
counter is incremented by 1.

11.17.3.41 C373566490 Percentage of HII in the range of 36 to 40


Definition

The counter is used to count the number of the HII percentage (36% to
40%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (36% to
40%).

Updated

When the being 1 percentage of HII bitmap is in range of 36% to 40%, the
counter is incremented by 1.

11.17.3.42 C373566491 Percentage of HII in the range of 41 to 45


Definition

The counter is used to count the number of the HII percentage (41% to
45%).
11-190

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (41% to
45%).

Updated

When the being 1 percentage of HII bitmap is in range of 41% to 45%, the
counter is incremented by 1.

11.17.3.43 C373566492 Percentage of HII in the range of 46 to 50


Definition

The counter is used to count the number of the HII percentage (46% to
50%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (46% to
50%).

Updated

When the being 1 percentage of HII bitmap is in range of 46% to 50%, the
counter is incremented by 1.

11.17.3.44 C373566493 Percentage of HII in the range of 51 to 55


Definition

The counter is used to count the number of the HII percentage (51% to
55%).
11-191

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (51% to
55%).

Updated

When the being 1 percentage of HII bitmap is in range of 51% to 55%, the
counter is incremented by 1.

11.17.3.45 C373566494 Percentage of HII in the range of 56 to 60


Definition

The counter is used to count the number of the HII percentage (56% to
60%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (56% to
60%).

Updated

When the being 1 percentage of HII bitmap is in range of 56% to 60%, the
counter is incremented by 1.

11.17.3.46 C373566495 Percentage of HII in the range of 61 to 65


Definition

The counter is used to count the number of the HII percentage (61% to
65%).
11-192

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (61% to
65%).

Updated

When the being 1 percentage of HII bitmap is in range of 61% to 65%, the
counter is incremented by 1.

11.17.3.47 C373566496 Percentage of HII in the range of 66 to 70


Definition

The counter is used to count the number of the HII percentage (66% to
70%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (66% to
70%).

Updated

When the being 1 percentage of HII bitmap is in range of 66% to 70%, the
counter is incremented by 1.

11.17.3.48 C373566497 Percentage of HII in the range of 71 to 75


Definition

The counter is used to count the number of the HII percentage (71% to
75%).
11-193

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (71% to
75%).

Updated

When the being 1 percentage of HII bitmap is in range of 71% to 75%, the
counter is incremented by 1.

11.17.3.49 C373566498 Percentage of HII in the range of 76 to 80


Definition

The counter is used to count the number of the HII percentage (76% to
80%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (76% to
80%).

Updated

When the being 1 percentage of HII bitmap is in range of 76% to 80%, the
counter is incremented by 1.

11.17.3.50 C373566499 Percentage of HII in the range of 81 to 85


Definition

The counter is used to count the number of the HII percentage (81% to
85%).
11-194

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (81% to
85%).

Updated

When the being 1 percentage of HII bitmap is in range of 81% to 85%, the
counter is incremented by 1.

11.17.3.51 C373566500 Percentage of HII in the range of 86 to 90


Definition

The counter is used to count the number of the HII percentage (86% to
90%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (86% to
90%).

Updated

When the being 1 percentage of HII bitmap is in range of 86% to 90%, the
counter is incremented by 1.

11.17.3.52 C373566501 Percentage of HII in the range of 91 to 95


Definition

The counter is used to count the number of the HII percentage (91% to
95%).
11-195

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (91% to
95%).

Updated

When the being 1 percentage of HII bitmap is in range of 91% to 95%, the
counter is incremented by 1.

11.17.3.53 C373566502 Percentage of HII in the range of 96 to 100


Definition

The counter is used to count the number of the HII percentage (96% to
100%).

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the LOAD INFORMATION message to other


eNodeBs.

Explanation

If the UL High Interference Indication IE is received in the LOAD


INFORMATION message, it indicates, per PRB, the occurrence of high
interference sensitivity, as seen from the sending eNB. The receiving eNB
should try to avoid scheduling cell edge UEs in its cells for the concerned
PRBs. The counter provides the number of the HII percentage (96% to
100%).

Updated

When the being 1 percentage of HII bitmap is in range of 96% to 100%,


the counter is incremented by 1.

11.17.3.54 C373566503 HII exceeds a threshold Time


Definition

The counter is used to count the time that that NI exceeds the threshold.

Sampling Interval

1 ms
11-196

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

Counter Type

Accumulative

Unit

ms

Measurement Object

Cell

Sampling Point

When the NI of RBs detected by eNodeB exceed the threshold.

Explanation

The eNodeB collect the NI of all RBs at sampling time and get the average
NI about all RB. If the average NI is larger the threshold, the counter is
incremented by the sampling period.

Updated

When the NI of RBs detected by eNodeB exceed the threshold, the counter
is incremented by the sampling period.

11.18 TTI Bundling


11.18.1 Flow Charts and Sampling Points
No chart.

11.18.2 Counter List


NO.

Counter

Counter Name

Number
1

C373424688

Number of TTI bundling activation request

C373424689

Number of TTI bundling activation completed

C373424690

Number of TTI bundling deactivation request

C373424691

Number of TTI bundling deactivation completed

11.18.3 Counter Description


11.18.3.1 C373424688 Number of TTI bundling activation request
Definition

The counter is used to count the number of TTI bundling activation request.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message


due to activate the TTI bundling.
11-197

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The counter provides the number of TTI bundling activation requests.

Updated

The counter is increased by 1 when the eNodeB sends the


RRCConnectionReconfiguration message due to activate the TTI bundling.

11.18.3.2 C373424689 Number of TTI bundling activation completed


Definition

The counter is used to count the number of TTI bundling activation


completed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message for TTI bundling activation completing.

Explanation

The counter provides the number of completed TTI bundling activations.

Updated

The counter is increased by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message for TTI bundling
activation completing.

11.18.3.3 C373424690 Number of TTI bundling deactivation request


Definition

The counter is used to count the number of TTI bundling deactivation


request.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB sends the RRCConnectionReconfiguration message


due to deactivate the TTI bundling.

Explanation

The counter provides the number of TTI bundling deactivation requests.

Updated

The counter is increased by 1 when the eNodeB sends the


RRCConnectionReconfiguration message due to deactivate the TTI
bundling.

11-198
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 11 Statistics of Radio Resources

11.18.3.4 C373424691 Number of TTI bundling deactivation completed


Definition

The counter is used to count the number of TTI bundling deactivation


completed.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

Cell

Sampling Point

When the eNodeB receives the RRCConnectionReconfigurationComplete


message for TTI bundling deactivation completing.

Explanation

The counter provides the number of completed TTI bundling deactivations.

Updated

The counter is increased by 1 when the eNodeB receives the


RRCConnectionReconfigurationComplete message for TTI bundling
deactivation completing.

11-199
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

11-200
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 12

Statistics of Paging
Table of Contents
Paging......................................................................................................................12-1

12.1 Paging
12.1.1 Flow Charts and Sampling Points
Figure 12-1 Paging

Sampling Point 1: When the eNodeB receives the Paging message from the MME.

12.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373394400

Number of Paging Records Received by the eNodeB

C373394401

Number of Paging Records Discarded at the eNodeB

C373394402

Number of Paging Records Congested at the eNodeB

12.1.3 Counter Description


12.1.3.1 C373394400 Number of Paging Records Received by the eNodeB
Definition

The counter is used to count the number of paging message from the MME.

12-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB receives the paging message from the MME.

Explanation

Reception of a S1AP PAGING message from MME,the eNodeB can be


queued. When each paging occasion reach, the paging will be transmitted.

Updated

The counter is incremented by 1 when the eNodeB receives the paging


message from the MME.

12.1.3.2 C373394401 Number of Paging Records Discarded at the eNodeB


Definition

The counter is used to count the number of paging records that are
discarded by the eNodeB.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the eNodeB sends the paging records failures.

Explanation

Reception of a S1AP PAGING message from MME,the eNodeB can be


queued. When each paging occasion reach, the paging will be transmitted.
If the paging is discarded by eNodeB,the counter records.

Updated

The counter is incremented by 1 when the eNodeB sends the paging


message failures.

12.1.3.3 C373394402 Number of Paging Records Congested at the eNodeB


Definition

The counter is used to count the number of paging records that are
congested at the eNodeB for paging occasions.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Unit

Measurement Object

Cell

Sampling Point

When the paging records that are congested at the eNodeB for paging
occasions.

12-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 12 Statistics of Paging

Explanation

Reception of a S1AP PAGING message from MME,the eNodeB can be


queued. When each paging occasion reach, the paging will be transmitted.
If the paging is congested by eNodeB at paging occasions, the counter
records.

Updated

The counter is incremented by 1 when the paging record congested for


paging occasions.

12-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

12-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13

Statistics of Transport
Resources
Table of Contents
Throughput on IP Pair ..............................................................................................13-1
Vlan Throughput on IP Pair ......................................................................................13-3
Dscp Throughput on IP Pair .....................................................................................13-6
Total Throughput on eNodeB....................................................................................13-8
SCTP Link..............................................................................................................13-20
OAM Link ...............................................................................................................13-21

13.1 Throughput on IP Pair


13.1.1 Flow Charts and Sampling Points
No chart.

13.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373840000

IP Pair Sending Maximum Throughput

C373840001

IP Pair Receiving Maximum Throughput

C373840002

IP Pair Sending Average Throughput

C373840003

IP Pair Receiving Average Throughput

13.1.3 Counter Description


13.1.3.1 C373840000 IP Pair Sending Maximum Throughput
Definition

The counter is used to count the maximum UL throughput of ethernet


packets on IP pair.

Sampling Interval

10 s

13-1
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Maximum

Unit

Mbps

Measurement Object

IP Pair

Sampling Point

When the data is transmitted on the transmission layer IP pairs of eNodeB.

Explanation

At sampling time, the eNodeB collects the transport volume to assigning IP


Pair on the uplink from the previous sampling time to the current sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current throughput
of ip pair transmitted by transport layer is larger than the prior at sampling
point.

13.1.3.2 C373840001 IP Pair Receiving Maximum Throughput


Definition

The counter is used to count the maximum DL throughput of ethernet


packets on IP pair.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

IP Pair

Sampling Point

When the data is received on the transmission layer IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the transport volume to assigning


IP Pair on the downlink from the previous sampling time to the current
sampling time. The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced with the current value when the current received
throughput in ip pair is larger than the prior at sampling point.

13.1.3.3 C373840002 IP Pair Sending Average Throughput


Definition

The counter is used to count the average UL throughput of ethernet


packets on IP pair.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

IP Pair

Sampling Point

When the data is transmitted on the transmission layer IP pairs of the


eNodeB.
13-2

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Explanation

At sampling time, the eNodeB collects the transport volume to assigning IP


Pair on the uplink from the previous sampling time to the current sampling
time. The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by accumulating all the sample transmitted


throughput in ip pair, and then dividing the sum by the measurement period.

13.1.3.4 C373840003 IP Pair Receiving Average Throughput


Definition

The counter is used to count the average DL throughput of ethernet


packets on IP pair.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

IP Pair

Sampling Point

When the data is received on the transmission layer IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the transport volume to assigning


IP Pair on the downlink from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample received throughput


in ip pair, and then dividing the sum by the measurement period.

13.2 Vlan Throughput on IP Pair


13.2.1 Flow Charts and Sampling Points
No chart.

13.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373900000

IP Pair Vlan Sending Maximum Throughput

C373900001

IP Pair Vlan Receiving Maximum Throughput

C373900002

IP Pair Vlan Sending Average Throughput

C373900003

IP Pair Vlan Receiving Average Throughput

13-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

13.2.3 Counter Description


13.2.3.1 C373900000 IP Pair Vlan Sending Maximum Throughput
Definition

The counter is used to count the maximum UL throughput of ethernet


packets per Vlan on IP pair.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

IP Pair Vlan

Sampling Point

When the data is transmitted on the current VLAN of the transmission


layer IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the UL transport volume to assigning


Vlan on IP Pair from the previous sampling time to the current sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current throughput
of ip pair transmitted by transport layer is larger than the prior at sampling
point.

13.2.3.2 C373900001 IP Pair Vlan Receiving Maximum Throughput


Definition

The counter is used to count the maximum DL throughput of ethernet


packets per Vlan on IP pair.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

IP Pair Vlan

Sampling Point

When the data is received on the current VLAN of the transmission layer
IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the DL transport volume to assigning


Vlan on IP Pairfrom the previous sampling time to the current sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current received
throughput in ip pair is larger than the prior at sampling point.

13-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

13.2.3.3 C373900002 IP Pair Vlan Sending Average Throughput


Definition

The counter is used to count the average UL throughput of ethernet


packets per Vlan on IP pair.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

IP Pair Vlan

Sampling Point

When the data is transmitted on the current VLAN of the transmission


layer IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the UL transport volume to


assigning Vlan on IP Pair from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample transmitted


throughput in ip pair, and then dividing the sum by the measurement period.

13.2.3.4 C373900003 IP Pair Vlan Receiving Average Throughput


Definition

The counter is used to count the average DL throughput of ethernet


packets per Vlan on IP pair.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

IP Pair Vlan

Sampling Point

When the data is received on the current VLAN of the transmission layer
IP pairs of the eNodeB.

Explanation

At sampling time,the eNodeB collects the DL transport volume to assigning


Vlan on IP Pair on the downlink from the previous sampling time to the
current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample received throughput


in ip pair, and then dividing the sum by the measurement period.

13-5
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

13.3 Dscp Throughput on IP Pair


13.3.1 Flow Charts and Sampling Points
No chart.

13.3.2 Counter List


NO.

Counter

Counter Name

Number
1

C373850000

Dscp Sending Maximum Throughput

C373850001

Dscp Receiving Maximum Throughput

C373850002

Dscp Sending Average Throughput

C373850003

Dscp Receiving Average Throughput

13.3.3 Counter Description


13.3.3.1 C373850000 Dscp Sending Maximum Throughput
Definition

The counter is used to count the maximum UL throughput of ethernet


packets per DSCP on IP pair.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

IP Pair Dscp

Sampling Point

When the data is transmitted on the current DSCP of the transmission


layer IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the UL transport volume to assigning


DSCP on IP Pair from the previous sampling time to the current sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current throughput
of ip pair transmitted by transport layer is larger than the prior at sampling
point.

13.3.3.2 C373850001 Dscp Receiving Maximum Throughput


Definition

The counter is used to count the maximum DL throughput of ethernet


packets per DSCP on IP pair.
13-6

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

IP Pair Dscp

Sampling Point

When the data is received on the current DSCP of the transmission layer
IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the DL transport volume to assigning


DSCP on IP Pairfrom the previous sampling time to the current sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the current value when the current received
throughput in ip pair is larger than the prior at sampling point.

13.3.3.3 C373850002 Dscp Sending Average Throughput


Definition

The counter is used to count the average UL throughput of ethernet


packets per DSCP on IP pair.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

IP Pair Dscp

Sampling Point

When the data is transmitted on the current DSCP of the transmission


layer IP pairs of the eNodeB.

Explanation

At sampling time, the eNodeB collects the UL transport volume to


assigning DSCP on IP Pair from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by accumulating all the sample transmitted


throughput in ip pair, and then dividing the sum by the measurement period.

13.3.3.4 C373850003 Dscp Receiving Average Throughput


Definition

The counter is used to count the average DL throughput of ethernet


packets per DSCP on IP pair.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

IP Pair Dscp
13-7

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Point

When the data is received on the current DSCP of the transmission layer
IP pairs of the eNodeB.

Explanation

At sampling time,the eNodeB collects the DL transport volume to assigning


DSCP on IP Pair on the downlink from the previous sampling time to the
current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by accumulating all the sample received throughput


in ip pair, and then dividing the sum by the measurement period.

13.4 Total Throughput on eNodeB


13.4.1 Flow Charts and Sampling Points
No chart.

13.4.2 Counter List


NO.

Counter

Counter Name

Number
1

C373930000

Control Plane Sending S1 Average Throughput

C373930001

Control Plane Receiving S1 AverageThroughput

C373930002

Control Plane Sending X2 Average Throughput

C373930003

Control Plane Receiving X2 Average Throughput

C373930004

Control Plane Sending OAM Average Throughput

C373930005

Control Plane Receiving OAM Average Throughput

C373930006

Control Plane Sending S1 Maximum Throughput

C373930007

Control Plane Receiving S1 Maximum Throughput

C373930008

Control Plane Sending X2 Maximum Throughput

10

C373930009

Control Plane Receiving X2 Maximum Throughput

11

C373930010

Control Plane Sending OAM Maximum Throughput

12

C373930011

Control Plane Receiving OAM Maximum Throughput

13

C373930012

User Plane Sending S1 Average Throughput

14

C373930013

User Plane Receiving S1 Average Throughput

15

C373930014

User Plane Sending X2 Average Throughput

16

C373930015

User Plane Receiving X2 Average Throughput

17

C373930016

User Plane Sending Other Average Throughput

13-8
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

NO.

Counter

Counter Name

Number
18

C373930017

User Plane Receiving Other Average Throughput

19

C373930018

User Plane Sending S1 Maximum Throughput

20

C373930019

User Plane Receiving S1 Maximum Throughput

21

C373930020

User Plane Sending X2 Maximum Throughput

22

C373930021

User Plane Receiving X2 Maximum Throughput

23

C373930022

User Plane Sending Other Maximum Throughput

24

C373930023

User Plane Receiving Other Maximum Throughput

25

C373930024

Maximum UL Total Throughput on Transport Layer

26

C373930025

Maximum DL Total Throughput on Transport Layer

13.4.3 Counter Description


13.4.3.1 C373930000 Control Plane Sending S1 Average Throughput
Definition

The counter is used to count the average UL throughput sent by eNodeB


to the MME.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the signaling message in sctp link to the MME.

Explanation

At sampling time, the eNodeB collects the transport UL volume sent to


the MME on SCTP link from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.2 C373930001 Control Plane Receiving S1 AverageThroughput


Definition

The counter is used to count the average DL throughput received by


eNodeB from the MME.

Sampling Interval

10 s

Counter Type

Average
13-9

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the signaling in sctp link from the MME.

Explanation

At sampling time, the eNodeB collects the transport DL volume received


from the MME on SCTP link from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.3 C373930002 Control Plane Sending X2 Average Throughput


Definition

The counter is used to count the average UL throughput sent by eNodeB


to other eNodeB.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the signaling in sctp link to another eNodeB.

Explanation

At sampling time, the eNodeB collects the transport UL volume sent to the
target eNodeB on SCTP link from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.4 C373930003 Control Plane Receiving X2 Average Throughput


Definition

The counter is used to count the average DL throughput received by


eNodeB from other eNodeB.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the signaling in sctp link from another eNodeB.

13-10
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Explanation

At sampling time, the eNodeB collects the transport DL volume received


from the target eNodeB on SCTP link from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.5 C373930004 Control Plane Sending OAM Average Throughput


Definition

The counter is used to count the average UL throughput sent by eNodeB


to the OMC.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the message to the OMC.

Explanation

At sampling time, the eNodeB collects the transport volume sent to the
OMC from the previous sampling time to the current sampling time.
The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.6 C373930005 Control Plane Receiving OAM Average Throughput


Definition

The counter is used to count the average DL throughput received by


eNodeB from the OMC.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the message from the OMC.

Explanation

At sampling time, the eNodeB collects the transport volume received from
the OMC on SCTP link from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.
13-11

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

13.4.3.7 C373930006 Control Plane Sending S1 Maximum Throughput


Definition

The counter is used to count the maximum UL throughput sent by eNodeB


to the MME.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the signaling message in sctp link to the MME.

Explanation

At sampling time, the eNodeB collects the transport UL volume sent to the
MME on SCTP link from the previous sampling time to the current sampling
time.The counter provides the maximum value in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.8 C373930007 Control Plane Receiving S1 Maximum Throughput


Definition

The counter is used to count the maximum DL throughput received by


eNodeB from the MME.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the signaling in sctp link from the MME.

Explanation

At sampling time, the eNodeB collects the transport DL volume received


from the MME on SCTP link from the previous sampling time to the
current sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.9 C373930008 Control Plane Sending X2 Maximum Throughput


Definition

The counter is used to count the maximum UL throughput sent by eNodeB


to other eNodeB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps
13-12

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the signaling in sctp link to another eNodeB.

Explanation

At sampling time, the eNodeB collects the transport UL volume sent to


the target eNodeB on SCTP link from the previous sampling time to the
current sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.10 C373930009 Control Plane Receiving X2 Maximum Throughput


Definition

The counter is used to count the maximum DL throughput received by


eNodeB from other eNodeB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the signaling in sctp link from another eNodeB.

Explanation

At sampling time, the eNodeB collects the transport DL volume received


from the target eNodeB on the downlink from the previous sampling time
to the current sampling time.The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.11 C373930010 Control Plane Sending OAM Maximum Throughput


Definition

The counter is used to count the maximum UL throughput sent by eNodeB


to the OMC.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends the message to the OMC.

Explanation

At sampling time, the eNodeB collects the transport volume sent to the
OMC from the previous sampling time to the current sampling time.The
counter provides the maximum value in the measurement period.
13-13

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.12 C373930011 Control Plane Receiving OAM Maximum Throughput


Definition

The counter is used to count the maximum DL throughput received by


eNodeB from the OMC.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives the message from the OMC.

Explanation

At sampling time, the eNodeB collects the transport volume received


from the OMC on the downlink from the previous sampling time to the
current sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.13 C373930012 User Plane Sending S1 Average Throughput


Definition

The counter is used to count the average UL throughput sent by eNodeB


to the SGW.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When there are user plane data transmitted from The eNodeB to the SGW.

Explanation

At sampling time, the eNodeB collects the transport traffic volume sent to
the SGW on the uplink from the previous sampling time to the current
sampling time. The counter provides the average value of all sampling
point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13-14
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

13.4.3.14 C373930013 User Plane Receiving S1 Average Throughput


Definition

The counter is used to count the average DL throughput received by


eNodeB from the SGW.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When The eNodeB receives the user plane data from the SGW.

Explanation

At sampling time, the eNodeB collects the transport traffic volume received
from the SGW on the downlink from the previous sampling time to the
current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.15 C373930014 User Plane Sending X2 Average Throughput


Definition

The counter is used to count the average UL throughput sent by eNodeB


to other eNodeB.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When there are user plane data transmitted from the source eNodeB to
the target eNodeB.

Explanation

At sampling time, the eNodeB collects the transport traffic volume sent
to the target eNodeB on the uplink from the previous sampling time to
the current sampling time. The counter provides the average value of all
sampling point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.16 C373930015 User Plane Receiving X2 Average Throughput


Definition

The counter is used to count the average DL throughput received by


eNodeB from other eNodeB.

Sampling Interval

10 s
13-15

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When The eNodeB receives the data from another eNodeB.

Explanation

At sampling time, the eNodeB collects the transport traffic volume received
from the target eNodeB on the downlink from the previous sampling time
to the current sampling time. The counter provides the average value of
all sampling point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.17 C373930016 User Plane Sending Other Average Throughput


Definition

The counter is used to count the average UL throughput sent by eNodeB.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends other data, which are not included in the
S1/X2/OAM data.

Explanation

At sampling time, the eNodeB collects the transport other volume from the
previous sampling time to the current sampling time. The counter provides
the average value of all sampling point in the measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.18 C373930017 User Plane Receiving Other Average Throughput


Definition

The counter is used to count the average DL throughput received by


eNodeB.

Sampling Interval

10 s

Counter Type

Average

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives other data, which are not included in the
S1/X2/OAM data.

13-16
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Explanation

At sampling time, the eNodeB collects the transport other volume received
on the downlink from the previous sampling time to the current sampling
time. The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by calculating the average value of all of sampling


point in measurement period.

13.4.3.19 C373930018 User Plane Sending S1 Maximum Throughput


Definition

The counter is used to count the maximum UL throughput sent by eNodeB


to the SGW.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When there are user plane data transmitted from The eNodeB to the SGW.

Explanation

At sampling time, the eNodeB collects the transport volume sent to the
SGW on the uplink from the previous sampling time to the current sampling
time.The counter provides the maximum value in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.20 C373930019 User Plane Receiving S1 Maximum Throughput


Definition

The counter is used to count the maximum DL throughput received by


eNodeB from the SGW.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When The eNodeB receives the user plane data from the SGW.

Explanation

At sampling time, the eNodeB collects the transport volume received


from the SGW on the downlink from the previous sampling time to the
current sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13-17
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

13.4.3.21 C373930020 User Plane Sending X2 Maximum Throughput


Definition

The counter is used to count the maximum UL throughput sent by eNodeB


to other eNodeB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When there are user plane data transmitted from The eNodeB to The
eNodeB.

Explanation

At sampling time, the eNodeB collects the transport traffic volume sent to
the target eNodeB on the uplink from the previous sampling time to the
current sampling time.The counter provides the maximum value in the
measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.22 C373930021 User Plane Receiving X2 Maximum Throughput


Definition

The counter is used to count the maximum DL throughput received by


eNodeB from other eNodeB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When The eNodeB receives the data from another eNodeB.

Explanation

At sampling time, the eNodeB collects the transport traffic volume received
from the target eNodeB on the downlink from the previous sampling time
to the current sampling time.The counter provides the maximum value
in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.23 C373930022 User Plane Sending Other Maximum Throughput


Definition

The counter is used to count the maximum UL throughput sent by eNodeB.

Sampling Interval

10 s

Counter Type

Maximum
13-18

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB sends other data, which are not included in the
S1/X2/OAM data.

Explanation

At sampling time, the eNodeB collects the transport other volume sent
from the previous sampling time to the current sampling time. The counter
provides the maximum value in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.24 C373930023 User Plane Receiving Other Maximum Throughput


Definition

The counter is used to count the maximum DL throughput received by


eNodeB.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When the eNodeB receives other data, which are not included in the
S1/X2/OAM data.

Explanation

At sampling time, the eNodeB collects the transport other volume received
on the downlink from the previous sampling time to the current sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.25 C373930024 Maximum UL Total Throughput on Transport Layer


Definition

The counter is used to count the maximum UL throughput sent by eNodeB


from the SGW.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When The eNodeB receives the user plane data from the SGW.

13-19
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

At sampling time, the eNodeB collects the transport volume sent on the
uplink from the previous sampling time to the current sampling time.The
counter provides the maximum value in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.4.3.26 C373930025 Maximum DL Total Throughput on Transport Layer


Definition

The counter is used to count the maximum DL throughput received by


eNodeB to the SGW.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Mbps

Measurement Object

eNodeB

Sampling Point

When there are user plane data transmitted from The eNodeB to the SGW.

Explanation

At sampling time, the eNodeB collects the transport volume received on


the downlink from the previous sampling time to the current sampling
time.The counter provides the maximum value in the measurement period.

Updated

The counter is replaced by the current value when it is larger than the
counter.

13.5 SCTP Link


13.5.1 Flow Charts and Sampling Points
The SCTP link refers to the link between eNodeB and MME or eNodeB and eNodeB. The
statistics of the link includes the disconnection times and service time. The link fault is
reflected by SCTP disconnection times and the normal service time is reflected by the
available time of SCTP link.

13.5.2 Counter List


NO.

Counter

Counter Name

Number
1

C373920000

Disconnection Times Per SCTP Link

C373920001

Sctp Link Service Time

13-20
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

13.5.3 Counter Description


13.5.3.1 C373920000 Disconnection Times Per SCTP Link
Definition

The counter is used to count the number of breakage on SCTP link.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

IP Sctp

Sampling Point

When the SCTP link is detected breakdown.

Explanation

The peirod heartbeat message will be send in the SCTP link.If the
heartbeat is detected abnormally, the eNodeB will report the link fault and
statics the disconnection.

Updated

The counter is incremented by 1 when the SCTP link is detected


breakdown.

13.5.3.2 C373920001 Sctp Link Service Time


Definition

The counter is used to count the time SCTP link has been available.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Measurement Object

IP Sctp

Sampling Point

The eNodeB collects the SCTP link service time at sampling time
according to "Explanation".

Explanation

The sampling rule of SCTP link service time is as follows:


When the eNodeB successfully setup the SCTP link, record the start
time. When the eNodeB detect the SCTP link abnormal, record the end
time.The SCTP link service time is equal to the interval from the start time
to the end time.

Updated

The counter is incremented by the SCTP link service time at sampling point.

13.6 OAM Link


13.6.1 Flow Charts and Sampling Points
The OAM link refers to the link between eNodeB and OAM. The statistics of the link
includes the disconnection times and service time. The link fault is reflected by OAM
13-21
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

disconnection times and the normal service time is reflected by the available time of OAM
link.

13.6.2 Counter List


NO.

Counter

Counter Name

Number
1

C373950430

Disconnection Times Per OAM Link

C373950431

OAM Link Service Time

13.6.3 Counter Description


13.6.3.1 C373950430 Disconnection Times Per OAM Link
Definition

The counter is used to count the number of breakage on OAM link.

Sampling Interval

Event triggered

Counter Type

Accumulative

Unit

Times

Measurement Object

eNodeB

Sampling Point

When the link between the eNodeB and the OMC is detected breakdown
by eNodeB.

Explanation

The peirod heartbeat message will be send in the link between eNodeB
and OMC. If the heartbeat is detected abnormally, the eNodeB will report
the link fault and statics the disconnection.

Updated

The counter is incremented by 1 when the link between the eNodeB and
the OMC is detected breakdown by eNodeB.

13.6.3.2 C373950431 OAM Link Service Time


Definition

The counter is used to count the time OAM link has been available.

Sampling Interval

15 min

Counter Type

Accumulative

Unit

Measurement Object

eNodeB

Sampling Point

When the eNodeB successfully setup the OAM link, record the start time;
When the eNodeB detect the OAM link abnormal, record the end time.The
OAM link service time is equal to the interval from the start time to the
end time.
13-22

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 13 Statistics of Transport Resources

Explanation

The OAM link refer to the link from the eNodeB to the OMC.

Updated

The counter is incremented by the OAM link service time at per


measurement period.

13-23
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

This page intentionally left blank.

13-24
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 14

Statistics of System
Resources
Table of Contents
CPU Resources .......................................................................................................14-1
Memory Resources ..................................................................................................14-3

14.1 CPU Resources


14.1.1 Flow Charts and Sampling Points
The statistic of CPU Utilization of the eNodeB CC board includes peak CPU utilization rate,
average CPU utilization rate and duration when CPU load is higher than threshold.

14.1.2 Counter List


NO.

Counter

Counter Name

Number
1

C373940400

Peak CPU Utilization Rate of ENB CC Board

C373940401

Average CPU Utilization Rate of ENB CC Board

C373940402

Duration When CPU Load Is Higher Than Threshold

14.1.3 Counter Description


14.1.3.1 C373940400 Peak CPU Utilization Rate of ENB CC Board
Definition

The counter is used to count the peak usage of the main processor during
the granularity period.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Percent

Measurement Object

eNodeB

Sampling Point

The eNodeB collects the cpu usage at sampling time.


14-1

SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Explanation

The CPU utilization rate refers to the ratio of the time of main cpu running
and the total time. The eNodeB collects the cpu usage at per sampling
time. The counter provides the maximum value in the measurement period.

Updated

The counter is replaced with the new value when the CPU utilization rate in
a sampling point is larger than the counter.

14.1.3.2 C373940401 Average CPU Utilization Rate of ENB CC Board


Definition

The counter is used to count the mean usage of the main processor during
the granularity period.

Sampling Interval

10 s

Counter Type

Average

Unit

Percent

Measurement Object

eNodeB

Sampling Point

The eNodeB collects the cpu usage at sampling time.

Explanation

The CPU utilization rate refers to the ratio of the time of main cpu running
and the total time. The eNodeB collects the cpu usage at per sampling
time. The counter provides the average value of all sampling point in the
measurement period.

Updated

The counter is updated by the mean of CPU utilization rate in measurement


period.

14.1.3.3 C373940402 Duration When CPU Load Is Higher Than Threshold


Definition

The counter is used to count the overload time of the main processor.

Sampling Interval

10 s

Counter Type

Accumulative

Unit

Measurement Object

eNodeB

Sampling Point

When the CPU load is higher than the threshold at sampling time.

Explanation

The CPU utilization rate refers to the ratio of the time of main cpu running
and the total time. The eNodeB collects the cpu usage at per sampling
time and compare it with the threshold. If it is higher than the threshold, the
counter is incremented by the sampling period.

Updated

The counter is incremented by time when the CPU load is higher.

14-2
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Chapter 14 Statistics of System Resources

14.2 Memory Resources


14.2.1 Flow Charts and Sampling Points
The statistic of memory utilization of the eNodeB CC board includes peak memory
utilization rate, average memory utilization rate, duration when memory load is higher
than threshold.

14.2.2 Counter List


NO.

Counter

Counter Name

Number
1

C373940403

Peak Memory Utilization Rate of ENB CC Board

C373940404

Average Memory Utilization Rate of ENB CC Board

C373940405

Duration When Memory Load Is Higher Than Threshold

14.2.3 Counter Description


14.2.3.1 C373940403 Peak Memory Utilization Rate of ENB CC Board
Definition

The counter is used to count the peak usage of memory during the
granularity period.

Sampling Interval

10 s

Counter Type

Maximum

Unit

Percent

Measurement Object

eNodeB

Sampling Point

When the memory of eNB CC board runs.

Explanation

The memory utilization rate refers to the ratio of the number of used
memory and the total number of memory. The eNodeB collects the
memory usage at per sampling time. The counter provides the maximum
value in the measurement period.

Updated

The counter is replaced with the new value when the memory utilization
rate in a sampling point is larger than the counter.

14.2.3.2 C373940404 Average Memory Utilization Rate of ENB CC Board


Definition

The counter is used to count the mean usage of memory during the
granularity period.

14-3
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Sampling Interval

10 s

Counter Type

Average

Unit

Percent

Measurement Object

eNodeB

Sampling Point

When the memory of eNB CC board runs.

Explanation

The memory utilization rate refers to the ratio of the number of used
memory and the total number of memory. The eNodeB collects the
memory usage at per sampling time. The counter provides the average
value of all sampling point in the measurement period.

Updated

The counter is updated by the mean of memory utilization rate in


measurement period.

14.2.3.3 C373940405 Duration When Memory Load Is Higher Than Threshold


Definition

The counter is used to count the overload time of memory.

Sampling Interval

10 s

Counter Type

Accumulative

Unit

Measurement Object

eNodeB

Sampling Point

When the memory load is higher than the threshold.

Explanation

The memory utilization rate refers to the ratio of the number of used
memory and the total number of memory. The eNodeB collects the memory
usage at per sampling time and compare it with the threshold. If it is higher
than the threshold, the counter is incremented by the sampling period.

Updated

The counter is incremented by time when the memory load is higher


threshold.

14-4
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Figures
Figure 1-1 RRC Connection Establishment............................................................... 1-2
Figure 1-2 RRC Connection Re-Establishment ....................................................... 1-15
Figure 1-3 RRC Connection again Re-Establishment.............................................. 1-16
Figure 1-4 RRC Connection Re-configuration ......................................................... 1-32
Figure 1-5 RRC Connection Release ...................................................................... 1-36
Figure 1-6 RRC Connection Number ...................................................................... 1-44
Figure 1-7 RRC Connection Number ...................................................................... 1-49
Figure 1-8 RRC Connection Setup Time ................................................................. 1-51
Figure 1-9 RRC Connection Setup to Reconfiguration Time.................................... 1-52
Figure 2-1 Initial E-RAB Setup .................................................................................. 2-2
Figure 2-2 Additional E-RAB Setup ......................................................................... 2-46
Figure 2-3 E-RAB Modification................................................................................ 2-88
Figure 2-4 E-RAB Release.................................................................................... 2-130
Figure 2-5 E-RAB Setup Time(1) .......................................................................... 2-280
Figure 2-6 E-RAB Setup Time(2) .......................................................................... 2-280
Figure 3-1 UE Context Setup .................................................................................... 3-2
Figure 3-2 UE Context Modification........................................................................... 3-8
Figure 3-3 UE Context Release .............................................................................. 3-12
Figure 3-4 Security Mode........................................................................................ 3-22
Figure 4-1 UE-associated Logical S1-connection ...................................................... 4-1
Figure 4-2 S1 Error Indication ................................................................................... 4-3
Figure 8-1 LTE-UTRAN Redirection .......................................................................... 8-1
Figure 8-2 LTE-CDMA Redirection............................................................................ 8-4
Figure 8-3 LTE-GSM Redirection .............................................................................. 8-8
Figure 9-1 Intra-eNB Handover ................................................................................. 9-2
Figure 9-2 X2 Handover(1) ..................................................................................... 9-12
Figure 9-3 X2 Handover(2) ..................................................................................... 9-13
Figure 9-4 S1 Handover(1) ..................................................................................... 9-25
Figure 9-5 S1 Handover(2) ..................................................................................... 9-27
Figure 9-6 Intra-eNB Handover ............................................................................... 9-38
Figure 9-7 X2 Handover(1) ..................................................................................... 9-48
Figure 9-8 X2 Handover(2) ..................................................................................... 9-49
I
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

ZXSDR UniRAN Performance Counter Reference

Figure 9-9 S1 Handover(1) ..................................................................................... 9-62


Figure 9-10 S1 Handover(2) ................................................................................... 9-63
Figure 9-11 Inter-RAT Handover ............................................................................. 9-75
Figure 9-12 S1 Handover(2) ................................................................................... 9-77
Figure 9-13 Inter-RAT Handover ............................................................................. 9-87
Figure 9-14 S1 Handover(2) ................................................................................... 9-89
Figure 9-15 Inter-RAT Handover ............................................................................. 9-99
Figure 9-16 S1 Handover(2) ................................................................................. 9-101
Figure 9-17 Intra-eNB Handover ........................................................................... 9-137
Figure 9-18 X2 Handover(1) ................................................................................. 9-147
Figure 9-19 X2 Handover(2) ................................................................................. 9-148
Figure 9-20 S1 Handover(1) ................................................................................. 9-161
Figure 9-21 S1 Handover(2) ................................................................................. 9-162
Figure 9-22 Intra-eNB Handover ........................................................................... 9-173
Figure 9-23 X2 Handover(1) ................................................................................. 9-183
Figure 9-24 X2 Handover(2) ................................................................................. 9-184
Figure 9-25 S1 Handover(1) ................................................................................. 9-197
Figure 9-26 S1 Handover(2) ................................................................................. 9-198
Figure 9-27 Inter-RAT Handover ........................................................................... 9-210
Figure 9-28 S1 Handover(2) ................................................................................. 9-212
Figure 9-29 Inter-RAT Handover ........................................................................... 9-222
Figure 9-30 S1 Handover(2) ................................................................................. 9-224
Figure 9-31 Inter-RAT Handover ........................................................................... 9-234
Figure 9-32 S1 Handover(2) ................................................................................. 9-236
Figure 9-33 RSRP and RSRQ of the Serving Cell ................................................. 9-250
Figure 9-34 RSRP and RSRQ of the Neighboring Cell .......................................... 9-266
Figure 9-35 X2 Handover Time ............................................................................. 9-282
Figure 9-36 S1 or Inter-RAT Handover Time ......................................................... 9-282
Figure 10-1 PDCP PDU Throughput ..................................................................... 10-23
Figure 10-2 RLC PDU Throughput ........................................................................ 10-51
Figure 10-3 MAC TB Throughput .......................................................................... 10-81
Figure 10-4 IP Latency........................................................................................ 10-121
Figure 10-5 PDCP PDU Throughput ................................................................... 10-209
Figure 10-6 RLC PDU Throughput ...................................................................... 10-237
Figure 10-7 MAC TB Throughput ........................................................................ 10-267

II
SJ-20121224143652-001|20130925(R1.6)

ZTE Proprietary and Confidential

Figures

Figure 10-8 IP Latency........................................................................................ 10-270


Figure 11-1 DL Transmit Power............................................................................... 11-2
Figure 11-2 BLER ................................................................................................. 11-36
Figure 12-1 Paging ................................................................................................. 12-1

III
SJ-20121224143652-001|20130925(R1.6)