Xc2002 Quick start guide

Dirk Schepens 10/01/2012

2915 6626 00 edition 00

1 Hardware

1 Hardware
Xc 2002 Control module - specs

2.1 Control panel buttons

2.2 Control panel LED functions

3.1 Main views survey

Navigation buttons allow


user to scroll through
readouts on display

3.2 Main views detailed


Initial view after power-up of the controller, is the fuel level and hour counter
The hour counter starts when the engine speed exceeds 800 min-1
The decimal indicator (.) will blink during counting
Fuel level:
 Fuel level is measured by means of a 0,54,5 VDC fuel level sender in the main fuel tank.
 A negativ fuel level indicates an incorrect signal due to a sensor failure or wiring defect

Icon View

Language view

Vessel pressure:
 Vessel pressure is measured by means of a 0,54,5 VDC sender in the load valve manifold.
 A negativ pressure indicates an incorrect signal due to a sensor failure or wiring defect

3.2 Main views detailed


Engine rpm:
 Engine rpm is measured by the engine electronics (EIC) and transmitted to the Xc2002 over Canbus.
 The value is only available when the engine is running

Battery voltage:
 The voltage is measured at the voltage in of the controller
 A too low value will case a charge fail warning

Service timers:
 The counter countes down to 0 meaning that the maintenance is due
 If not reset, a service warning will be displayed at every start-up

3.2 Main views detailed


Event logs:
 Up to 20 events can be logged.
 shutdowns, service timer resets, software downloads

LOG list
Alarms list:
 Displays all active alarms ( warnings & shutdowns).

Alarm list
2 Alarm(s)
Parameter:
 Opens subview where different parameters can be viewed and modified

Parameter
SW version:
 Shows version of currently loaded firmware

3.2 Main views detailed


Coolant temperature:
 Coolant temperature is measured by the engine electronics (EIC) and transmitted to the Xc2002 over Canbus

Engine oil pressure :


 Engine oil pressure is measured by the engine electronics (EIC) and transmitted to the Xc2002 over Canbus

10

4 Log list details


LOG list

Xc2002 EVENT LOG # 01


New software dl
Time:
000000h
Xc2002 EVENT LOG # 02
Element Temp. 1
Time:
000005h
Xc2002 EVENT LOG # 03
Emergency stop
Time:
000012h

The navigation buttons allow the user to


scroll trough the different event logs
( max 20)

Back to display views.

11

5 Alarm list details


Alarm list

2 Alarm(s)

The navigation buttons allow the user to


scroll trough the different active alarms

Back to display views.

12

5 Alarm list details


When an alarm is triggered, a pop-up screen will appear on the display and the alarm led
wiIl be activated.(continuous for a warning, on-off for a shutdown)
When the alarm is acknowledged (only that alarm in the popup screen), the alarm will
disappear when the fault is corrected (blinking led will then burn continuously)
Acknowledge is done by pressing the ENTER button.
An Unacknowledged shutdown will prevent the compressor from starting.
Unacknowledged alarm:

Acknowledged alarm:

The alarm pop-up will disappear when pressing the BACK button.
Active alarms can be viewed by entering the Alarm list.
Remark:
Sensor failure W -> sensor failure, at compressor side, casing a Warning
Sensor failure S -> sensor failure, at compressor side, casing a Shut down

13

6.1 Extra views survey


Extra Views

Navigation buttons allow the user to


scroll trough the extra views.

Back to display views.

14

6.2 Extra views detailed


Air inlet temperature:
 Air inlet temperature is measured by the engine electronics (EIC) and transmitted to the Xc2002 over Canbus

Engine Fuel consumption:


 Engine fuel consumptionis measured by the engine electronics (EIC) and transmitted to the Xc2002 over
Canbus

Engine Fuel pressure:


 Engine fuel pressure measured by the engine electronics (EIC) and transmitted to the Xc2002 over Canbus

15

6.2 Extra views detailed


Element temperature:
 Element temperature is monitored by a PT1000 sensor.

Regulating pressure:
 Regulating pressure is measured by a 0,54,5VDC sensor.
The value is used to control the engine speed

RegP
 00305.6h

16

0.00bar

7.1 Parameters survey


Parameter

Language
Icons

Unit
C/bar

C/bar

F/psi

Auto NoLoad
No

No

Yes

ST1 Reset
No

No

The navigation buttons allow the user to


scroll trough the different parameters

Yes

ST2 Reset
No

No

Yes

Unit Type
1

10

Production Test
No selection

Diagnostics
Off

Off

On

Back to display views.

17

7.2 Parameters details


Set language:

Language
Icons

Passw. 1999

Language
Icons

Passw. 2003

Language
English

Language
German

Language
Acknowledge

Spanish

Language
French

Back to parameters.

Language
Italian

Language
Cyrillic

18

7.2 Parameters details


Set units:

Unit
C/bar

C/bar

F/psi

Passw. 2003

Passw. 1999

Unit
C/bar

Unit
F/psi

Acknowledge

Back to parameters.

19

7.2 Parameters details


Activate Auto NoLoad:
 If active , unit will automatically go to NoLoad when in UnLoad for more then 60 sec.

Auto NoLoad
No

No

Yes

Passw. 2003

Passw. 1999

Auto NoLoad
No

Auto NoLoad
Yes

Acknowledge

Back to parameters.

20

7.2 Parameters details


Service Timer reset:
 Identical procedure for service timer 1 and service timer 2

ST1 Reset
No

No

Yes

Passw. 1968

Passw. 1999

ST1 Reset
No

ST1 Reset
Yes

Acknowledge

Back to parameters.

21

7.2 Parameters details


Set Unit type:
 Factory set, when initial unit type is set this list will dissapear from view and can only be
reset using the PARUS software. (consult GBP for latest list of unit types)

Unit Type
1

10

Passw. 1999
Unit Type

default

Unit Type

Passw. 2003

XAMS287DD

Unit Type

XAS850CD

Unit Type

XAMS287CD

Unit Type

XAMS407CD

Unit Type

XATS377CD

Acknowledge

Unit Type

XAHS237CD

Unit Type

XAHS347CD

Back to parameters.

Unit Type
9

Unit Type
10

22

XAVS307CD
XAH237DD

7.2 Parameters details


Diagnostics:
 When diagnostics is selected, power to the engine electronics will be interrupted for 30 sec.( engine will
shutdown if running at that time) before power comes back on in order to carry out engine diagnostics.

Diagnostics
Off

Off

On

Passw. 2003

Passw. 1999

Diagnostics
Off

Diagnostics
On

Acknowledge

Back to parameters.
Disable Diagnostics : switch diagnostics back to the OFF position, press STOP or start the unit.

23

8 Operation
START

If the unit is in Local control it can be started with this button.


Xc2002 will power up the EIC and initiate the Canbus communication. This can take a few seconds,
showing a WAIT pop-up on the display.
When Canbus communication is ok, Xc2002 will check if EIC is preheating the engine.
The display will show a Preheat pop-up.
After preheating or if no preheat was needed, the Xc controller will start the engine.
The starter motor is activated till the engine reaches 800rpm
After a warm-up to +40C at 1300 rpm, with a max. of 5 minutes, the compressor is ready for loading: the
LOAD led will blink
When loaded the first time, the engine speed will be raised to max. rpm for 7 sec.
Then the regulation system comes in action to adjust the speed.
If the LOAD button is applied during the warming up fase, LOAD led will blink fast and unit will
automatically load when warming up is finished.
When during Loaded operation the LOAD button is applied, load valve will be deactivated and
compressor will run in NoLoad at 1300rpm.

24

8 Operation
STOP

Compressor can be stopped with this button.


If compressor was running in LOAD the load valve will be deactivated and unit will return to NoLoad
(1300rpm). After 5 minutes cooldown, the engine will be stopped.
If running in NoLoad
when stopping , then cooldown time will be 5 minutes minus the time the unit has been running in
NoLoad.
If compressor has not been loaded there will be no cooldown time.
If ON/OFF button is switched to OFF with the unit running, the same procedure will be followed as when
the stop button was pushed.

25

8 Operation
AUTOMATIC

This compressor can be remotely controlled (start-stop-load-noload) trough digital inputs


The automatic button switches between local and remote mode.
When the Automatic led is lid , the unit is in remote control and start /stop buttons on the controller
cannot be used.

26

8.1 Operation: most common Icons

27

8.1 Operation: most common Icons

28

9 PARUS (PAR Utility Software)


Enabling Unit Type selection

29

1.

Start PARUS

2.

Connect to controller

3.

Select PARAMETERS

4.

Load parameters from controller

5.

Dubbelclick channel 8001

6.

Select the enable checkbox

7.

Write to the controller and close the window

8.

Disconnect PARUS

9.

Unit type selection is available in controller menu

We are committed to your


superior productivity through
interaction and innovation.

30