You are on page 1of 2

A.

GAS COMPOSITION
Composition of Natural Gas
Product
Mole %
CH4
95.73%
C2H6

2.06%

C3H8

0.86%

iC4H10

0.30%

nC4H10

0.16%

i C5H12

0.07%

n C5H12

0.05%

C6H14

0.02%

N2

0.51%

CO2

0.24% (max.)

H2S
Water Content:

5 PPM(max)
0.3 0.4 (v/v)

B. ENVIRONMENTAL SPECIFICATIONS
Site Conditions
Max. /Min. temperature

65 / -5 deg. Celsius.

Design Temperature

-20 C to 65 C

Relative Humidity

Max / Min. : 90%/ 41%

Hazardous Area classification

The hazardous area classification as per IS 5572/

IEC
C. Steel Pipeline sizes : 12, 8, 6 and 4. Isolation Valve located at 3km interval
Wall Thickness, mm 6.4
Service Natural Gas (Non-Sour)
Size (NPS), 12, 8, 6, 4
Design pressure, Barg 49
Design temperature, 0C -20 to +60
Max. Gas Velocity, m/s (Design) 20
Maximum Operating Pressure 26 bar g
D. ASSIGNMENT

1. Please calculate hold up volume of gas in between two Isolation Valves of 3km
apart for all the pipe sizes.
2. Envisage rupture in line covering 2, 4, 6, 8, 10 and 12 in the hold-up
segment.
3. Calculate the gas discharge and associate fire including radiant flux profile with
respect to radial distance from the rupture locations.