You are on page 1of 2

PROJECT

RESIDENTIAL HOUSE

OWNER

LITA SAMULDE ABAD

LOCATION :

BAGUMBAYAN, SAN JOSE, ANTIQUE

GENERAL SPECIFICATIONS
I.

SITE WORK
I.1 GENERAL SITE WORK

II.

I.1.1

ALL TREES & GROUP OF TREES, SHUBBERY,


AND
VISIBLE
STRUCTURES INDICATED IN THE DRAWINGS OR DESIGNATED BY THE
ARCHITECT TO BE LEFT STANDING SHALL BE PROPERLY PROTECTED
FROM DAMAGE INCIDENTAL TO CONSTRUCTION OPERATIONS BY THE
ERECTION OF SUITABLE BARRELS AS APPROVED BY THE OWNER.

I.1.2

UNDERTAKE GENERAL EXTERIOR GRADING, CUTTING, FILLING


REQUIRED TO TRANSFORM EXISTING GRADES TO THOSE SHOWN ON
DRAWINGS. SPREAD UNIFORM TOPSOIL OVER ENTIRE REDGRADED
AREA.

I.1.3

CONSTRUCT ALL SHORING, BRACING, PLANKING AND CRIBBING


REQUIRED AND UNDERTAKE REMOVAL OF THE SAME.

I.1.4

STAKE OUT THE BUILDING ACCURATELY, AND ESTABLISH GRADES,


PLACING SUCH WHERE THEY WILL NOT BE DISTURBED DURING THE
CONSTRUCTION OF THE FOUNDATIONS. CONTRACTOR SHALL BE
RESPONSIBLE FOR ANY VERIFICATIONS REQUIRED TO COMPLY WITH
SETBACKS REQUIRED BY THE MUNICIPAL, LOCAL OR SUBDIVISIONS
REGULATIONS.

I.1.5

THE AREAS WITHIN THE CONSTRUCTION WORK SHALL BE GRADED SO


AS TO ASSUREPROPER DRAINAGE AND PREVENT THE FORMING OF
POOLS.

I.1.6

ALL UTILITY LINES SHALL BE EXTENDED FROM THE BUILDING TO THE


UTILITY CONNECTION.

EXCAVATION
2.2.1 STRUCTURAL EXCAVATIONS SHALL BE TO THE DEPTHS INDICATED,
RECKONED EITHER FROM THE NATURAL GROUND LINE OF THE FINISHED
GRADE LINE WHICHEVER IS LOWER. THE INDICATED DEPTH IS THE
MINIMUM REQUIREMENT FOR EXCAVATION.
2.2.2 ALL STRUCTURAL EXCAVATIONS SHALL EXTEND TO A SUFFECIENT
DISTANCE FROM WALLS AND FOOTINGS TO ALLOW FOR THE PROPER
ERECTION AND DISMANTLING OF FORMS, INSTALLATION OF SERVICE LINES
AND FOR INSPECTION.
2.2.3 ALL EXCESS MATERIALS RESULTING FROM GRADING OPERATIONS
NOT REQUIRED OR UNSUITABLE FOR FILL OR BACKFILL SHALL BE DISPOSED
OF BY THE CONTRACTOR.

INSTALLATIONS. WORKMANSHIP SHALL CONFIRM TO


THE STANDARDS OF GOOD ENGINEERING PRACTICE.

10.7.15 COMPLETION OF ELECTRICAL WORKS: THE ELECTRICAL WORKS SHALL BE


CONSIDERED COMPLETED.
10.7.15.1 TEST RESULT OF ELECTRICAL INSTALLATIONS SHALL BE
SATISFACTORY TO THE OWNER OR HIS AUTHORIZED REPRESENTATIVE.
10.7.15.2 ISSUANCE OF THE CERTIFICATE OF ELECTRICAL INSPECTION
10.7.16 THE CONTRACTOR SHALL TAKE SPECIAL CARE TO INSTALL THE JUNCTION
BOXES AND PULL BOXES IN PLACES THAT WILL NOT AFFECT THE ESTHETICS OF THE
BUILDING.
10.7.17 GUARANTEE. THE ELECTRICAL WORKS SHALL BE GUARANTEED BY THE
ELECTRICAL CONTRACTOR FROM DEFECTS AT HIS OWN EXPENSE, WITHIN A PERIOD
OF ONE (1) YEAR AFTER COMPLETION.

PREPARED BY:

ELDION S. GUERRA
CIVIL ENGINEER
PRC

0124934

PTR

5436403
Date:
Place Issued:

APPROVED BY:
LITA SAMULDE ABAD
OWNER

4/14/2016
ILOILO
CITY