You are on page 1of 8

GMVC8

ComfortNet-Compatible
Two-Stage, Variable-Speed Gas Furnace
80% AFUE

Heating Input: 60,000100,000 BTU/h


Contents

Nomenclature......................................... 2
Product Specifications............................ 3
Dimensions............................................. 4
Airflow Data............................................ 5
Wiring Diagram ...................................... 7
Accessories............................................. 8

Standard Features

Cabinet Features

ComfortNet Communicating Systems compatible


Heavy-duty aluminized-steel dualdiameter, tubular heat exchanger
Two-stage gas valve provides quiet, economical heating
Durable Silicon Nitride igniter
Quiet two-speed induced draft blower
Uses ComfortNet communicating,
two-stage or single-stage thermostats
Self-diagnostic control board with constant memory fault
code history output to a dual 7-segment display
Color-coded low-voltage terminals with
provisions for electronic air cleaner and humidifier
Efficient and quiet variable-speed airflow system gently
ramps up or down according to heating or cooling demand
Multiple continuous fan speed
options offer quiet air circulation
Auto-Comfort and enhanced
dehumidification modes available
California Low NOx emissions-compliant models available
AHRI Certified; ETL Listed

Multi-position installation: upflow,


horizontal left or right
Convenient left or right connection
for gas and electrical service
Cabinet air leakage (QLeak) 2%
Heavy-gauge steel cabinet with durable
baked-enamel finish
Fully insulated heat exchanger
and blower section

* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you
own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation.
Online registration is not required in California or Qubec.

SS-GMVC8

www.goodmanmfg.com

9/15
Supersedes 4/15

Nomenclature

G
1

M
2

V
3

C
4

80
5,6

040
7,8,9

4
10

Brand
G - Goodman Brand

A
14

NOx
N - Natural Gas
X - Low NOx

S - Single Stage
H - Convertible Single Phase

AFUE
80 - 80% AFUE

Cabinet Width
A - 14" C - 21"
B - 17" D - 24"
Maximum CFM
2 - 800 CFM
3 - 1200 CFM
4 - 1600 CFM
5 - 2000 CFM

MBTU/h

A
13

Major Revision
A - Initial Release
B - 1st Revision

Motor
V - Variable Speed ECM / ComfortNet
E - Multi-Speed ECM
S - Single Speed

040 - 40,000 BTU/h


060 - 60,000 BTU/h
080 - 80,000 BTU/h

*
12

Minor Revision
A - Initial Release
B - 1st Revision

Configuration
M - Upflow/Horizontal
C - Downflow/Horizontal

Gas Valve
M - Modulating
C - Two Stage

C
11

100 - 100,000 BTU/h


120 - 120,000 BTU/h
140 - 140,000 BTU/h

www.goodmanmfg.com

SS-GMVC8

Specifications

GMVC8
0604B*B

GMVC8
0805C*B

GMVC8
1005C*B

60,000

80,000

100,000

Heating Capacity
High Fire Input (BTU/h)
High Fire Output (BTU/h) (below)
Natural Gas

48,000

64,000

80,000

LP Gas

48,000

64,000

80,000

42,000

56,000

70,000

Natural Gas

33,600

44,800

56,000

LP Gas

33,600

44,800

56,000

80

80

80

Available AC @ 0.5 ESP

1.5 - 4.0

2.0 - 5.0

2.0 - 5.0

Temperature Rise Range ( F)

20 - 50

20 - 50

25 - 55

10 x 8

10 x 10

10 x 10

Low Fire Input (BTU/h)


Low Fire Output (BTU/h) (below)

AFUE

Circulator Blower
Size (D x W)
Horsepower - RPM
Speed

Variable

Variable

Variable

Vent Diameter

No. of Burners

11.7

11.7

11.7

Electrical Data
Min. Circuit Ampacity
Max. Overcurrent Device (amps)

15

15

15

Ship Weight (lbs)

107

121

124

Natural Gas BTU/h; for altitudes above from 0 to 4,500 above sea level, reduce input rating 4% for each 1,000 above 4,500 altitude. Low-fire rate is 70% of
high-fire rate.
DOE AFUE based upon Isolated Combustion System (ICS)
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical
Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the
same size as noted.

Notes
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
Gas Service Connection FPT
Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all
existing local codes.

SS-GMVC8

www.goodmanmfg.com

Dimensions

Alt. Gas Inlet

19

33

20

Alt. Gas Inlet

27
High-Voltage Inlet

19

23

Alt. High Voltage

13

Low-Voltage Inlet

Alt. Low Voltage

23
28

Dimensions Key
Model

GMVC80604B*B

17

16

GMVC80805C*B

21

19

GMVC81005C*B

21

19

Minimum Clearances to Combustible Materials


Sides

Rear

Front

Bottom

Vent
SW

Top
1

C = If placed on combustible floor, the floor MUST be wood ONLY.


Notes:
For servicing or cleaning, a 24 front clearance is recommended.
Unit connections (electrical, flue, and drain) may necessitate greater clearances than the minimum clearances listed above.
In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
Refer to the appropriate USA and Canadian codes:

In the USA: the National Fuel Gas Code NFPA 54 / ANSI Z223.1
In Canada: the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2

www.goodmanmfg.com

SS-GMVC8

Airflow Data
GMVC80604B*B
Cooling Speeds
(@ .1" - .8" w.c. ESP)
Tap

Adjust

High-Stage
CFM

GMVC80604B*B
Heating Speeds
(@ .1" - .5" w.c. ESP; Rise Range: 20 - 50F)
Low-Stage
CFM

Tap

High-Stage
CFM

Low-Stage
CFM

Rise

Minus 10%

540

351

Minus 10%

1,125

788

46

Minus 5%

570

371

Minus 5%

1,188

831

43

Normal

600

390

Normal

1,250

875

41

Plus 5%

630

410

Plus 5%

1,313

919

39

Plus 10%

660

429

Plus 10%

1,375

963

38

Minus 10%

720

468

Minus 10%

1,215

851

43

Minus 5%

760

494

Minus 5%

1,283

898

40

Normal

800

520

Normal

1,350

945

38

Plus 5%

840

546

Plus 5%

1,418

992

36

Plus 10%

880

572

Plus 10%

1,485

1,040

35

Minus 10%

990

644

Minus 10%

1,305

914

40

Minus 5%

1,045

679

Minus 5%

1,378

964

38

Normal

1,100

715

Normal

1,450

1,015

36

Plus 5%

1,155

751

Plus 5%

1,523

1,066

34

Plus 10%

1,210

787

Plus 10%

1,595

1,117

33

Minus 10%

1,260

819

Minus 10%

1,395

977

37

Minus 5%

1,330

865

Minus 5%

1,473

1,031

35
33

Normal

1,400

910

Normal

1,550

1,085

Plus 5%

1,470

956

Plus 5%

1,628

1,139

31

Plus 10%

1,540

1,001

Plus 10%

1,705

1,194

30

GMVC80805C*B
Cooling Speeds
(@ .1" - .8" w.c. ESP)
Tap

Adjust

GMVC80805C*B
Heating Speeds
(@ .1" - .5" w.c. ESP; Rise Range: 20 - 50F)

High-Stage
CFM

Low-Stage
CFM

Minus 10%

720

Minus 5%

760

Adjust

Adjust

High-Stage
CFM

468

Minus 10%

494

Minus 5%

Tap

Low-Stage
CFM

Rise

1,350

945

49

1,425

998

46
44

Normal

800

520

Normal

1,500

1,050

Plus 5%

840

546

Plus 5%

1,575

1,103

42

Plus 10%

880

572

Plus 10%

1,650

1,155

40

Minus 10%

990

644

Minus 10%

1,440

1,008

46

Minus 5%

1,045

679

Minus 5%

1,520

1,064

44

Normal

1,100

715

Normal

1,600

1,120

42
40

Plus 5%

1,155

751

Plus 5%

1,680

1,176

Plus 10%

1,210

787

Plus 10%

1,760

1,232

38

Minus 10%

1,260

819

Minus 10%

1,530

1,071

44

Minus 5%

1,330

865

Normal

1,400

910

Plus 5%

1,470

956

Plus 10%

1,540

1,001

Minus 10%

1,620

1,053

Minus 5%

1,710

1,112

Minus 5%

1,615

1,131

41

Normal

1,700

1,190

39

Plus 5%

1,785

1,250

37

Plus 10%

1,870

1,309

36

Minus 10%

1,620

1,134

41

Minus 5%

1,710

1,197

39

Normal

1,800

1,170

Normal

1,800

1,260

37

Plus 5%

1,890

1,229

Plus 5%

1,890

1,323

35

Plus 10%

1,980

1,287

Plus 10%

1,980

1,386

34

See Notes on next page.

SS-GMVC8

www.goodmanmfg.com

Airflow Data (cont.)


GMVC81005C*B
Cooling Speeds
(@ .1" - .8" w.c. ESP)

GMVC81005C*B
Heating Speeds
(@ .1" - .5" w.c. ESP; Rise Range: 25 - 55F)

High-Stage
CFM

Low-Stage
CFM

Minus 5%
Normal
Plus 5%
Plus 10%

720
760
800
840
880

468
494
520
546
572

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

990
1,045
1,100
1,155
1,210

644
679
715
751
787

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

1,260
1,330
1,400
1,470
1,540

819
865
910
956
1,001

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

1,620
1,710
1,800
1,890
1,980

1,053
1,112
1,170
1,229
1,287

Tap

Adjust
Minus 10%

Tap

Adjust

High-Stage
CFM

Low-Stage
CFM

Rise

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

1,553
1,639
1,725
1,811
1,898

1,089
1,150
1,210
1,271
1,331

55
52
49
47
45

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

1,575
1,663
1,750
1,838
1,925

1,103
1,164
1,225
1,286
1,348

54
51
49
46
44

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

1,598
1,686
1,775
1,864
1,953

1,121
1,183
1,245
1,307
1,370

53
50
48
46
44

Minus 10%
Minus 5%
Normal
Plus 5%
Plus 10%

1,620
1,710
1,800
1,890
1,980

1,134
1,197
1,260
1,323
1,386

53
50
47
45
43

Notes
These charts are for furnaces installed at 0 - 4,500. At higher altitudes, a properly de-rated unit will have the same temperature rise at a particular CFM, while the ESP at that CFM
will be lower.
The installation must be adjusted to obtain a temperature rise within the range listed on the furnace nameplate.
Do not operate above .5 w.c. ESP in heating mode.
Propane gas installations will have a high-stage rise approximately 4F lower than shown in the tables.

Minimum Filter Sizes


Model #
Filter Size (in)

GMVC80604B*

GMVC80805C*

GMVC81005C*

(1) 16 x 25 (Side or Bottom)

(1) 16 x 25 (Side or Bottom)

(2) 16 x 25 (Side) or (1) 20 x 25 (Bottom)

Note: Other size filters of equal or greater surface area may be used; filters may also be centrally located.
Use 2 - 16 X 25 filters on side returns or 20 X 25 filter on bottom return if furnace is connected to a cooling unit over 4 tons nominal capacity.

www.goodmanmfg.com

SS-GMVC8

Wiring Diagram

WH
DISCONNECT

TO 115VAC/ 1 /60 HZ POWER SUPPLY WITH


OVERCURRENT PROTECTION DEVICE

BR

RD

PU

OR

PU

PU

2
1

5
4

BK

FS

OR

BK

EAC

HUMID IF IER

EAC
IND HI

RD

12

RD

CONT FAN
HEAT OFF DLY
T-STAT

BK

TWO- STAGE
INTEGRATED
CONTROL
MODULE

YL

11

115
VAC
40 VA

TRANSFORMER

DIAGNOSTIC
LED' S

HOT SURFACE
IGN IT ER

FLAME S ENSOR
115 V AC

Y1

Y2

W2

W1

WH

GR
PK

BK

CIRCULATOR
BLOWER

INDUCTOR CO IL

AUTO RESET PRIMARY


LIMIT CONTR OL

LOW FIRE PRESS.


SWITCH

24V HUM.

PS1 (2)

NO
W2
Y2

TO
MICRO

PS2 ( 12)

NO
C

HIGH FIRE
PRESS. S WTICH

MANUAL RESET ROLLOU T


LIMIT CONTR OLS

HL I ( 1)
MVL (13)

PM

MVH ( 14)
C

HI

MVC ( 8)

GND ( 5)

BK

BK

BLOW ER
COMPARTMENT
DOOR SW ITCH
(OPEN WHEN
DOOR OPEN)

GND

TR (11)
TO
R

WH
GND

24V HUM.

BL
GY

W1

24 V THERMOSTAT CONNECTIONS

BK

24 VAC
AUTO RESET AUXILIARY LIMIT
CONTR OLS

PSO (7)

DEHUM

5
4
3
2
1

TH (4)

HLO ( 10)

Y1

WH

BK

TO +VDC

NEUTRAL
40 V A
TRANSFORMER

DEHUM

PU

YL

SEE
NOTE 5

24
VAC

24V THERMOSTAT CONNECTIONS

DIP SWITCHES

RD

10

DEHUM ENABLE
TRIM ENABLE

RD

NEUTRAL

IND LO

IGN

FUSE 3 A

BL

NEUTRAL

ID
BLW R

FS

NEUTRAL

ELECTRONIC
AIR CLEANER

NEUTRAL

HUMID IF IER

HUM

4 CIRCUIT MOTOR
CONNECTOR

YL

BR

15

FUSE

ECM MTR
HARNESS

GN

BL
WH

BL

14

24 V
3A

RD

COOL PRFL
HEAT AF

13

TRIM %

SEE N OTE 6

HUM-OUT

L INE
COOL A F

GND
NEUTRAL

GND ( 4)
+ VDC (1)
INDOOR
AIR
CIRCULATOR
BLWR

RX (2)
TO
MICRO

TX (3)
AUX

INTEGRATED CON TROL M ODULE

HUMIDIF IER
NOTES:
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. I F ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED,
IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF
AT LEAST 105 $ C. USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH F OR MORE
THAN 2 SECONDS WHILE IN STANDBY (NO THERMOSTAT INPUTS)
6. HUMIDIFIER INSTALLATION OPTIONS: USE HUM TERMINAL TO RUN HUMIDIFIER DURING HEAT CALL
(COMMUNICATING OR LEGACY MODES). USE HUM-IN AND HUM-OUT TERMINALS TO RUN
HUMIDIFIER DURING HEAT CALL ( COMMUNICATING MODE OR LEGACY MODE) OR INDEPENDENTLY
FROM HEAT CALL (COMMUNICATING MODE ONLY - SETUP I S DONE WITHIN COMMUNICATING
THERMOSTAT)

COLOR CODES:
PK PINK
BR BROWN
WH WHITE
BL BLUE
GY GRAY
RD RED
YL YELLOW
OR ORANGE
PU PURPLE
GN GREEN
BK BLACK

INTEGRATED CONTROL MODULE

5 CIRCUIT CONNECTOR

HUM

HUMIN

HUMOUT

INTEGRATED CONTROL MODULE

BK
RD
WH

AUTO RESET
AUXIL IARY
LIMIT CONTROL

NEUTRAL

INDOOR
AIR
CIRCULATOR
BLW R

HUM-IN
L INE

PU

BLOWER COMPARTMENT

LINE

JUNCT ION BOX


INDUCTOR COIL
70kBTU ,9 0kBTU,
115kBTU MODELS
ONLY

GND

BURNER COMPARTMENT

DIS CONNECT

DOOR
SW ITCH

GN

INDUCED
DRAFT
BLOWER

WH
RD
BK

CHASSIS GROUND

AUTO RESET PRIMARY


LIMIT CONTROL

MANUAL RESET ROLLOUT LIMIT


CONTROLS

High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.

WH

GND

Warning

BL

WARNING:
DISCONNECT POWER
BEFORE SERVICING.
WIRING TO UNIT
MUST BE PROPERLY
POLARIZED AND
GROUNDED.

LOW VOLTAGE (24V)


LOW VOLTAGE FIELD
HI VOLTAGE (115V)
HI VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
INTEGRATED CONTROL
PLUG CONNECTION

FLAME
SENSOR

YL

EQUIPMENT GND

GAS
VALVE

Wiring is subject to change. Always


refer to the wiring diagram or the
unit for the most up-to-date wiring.

JUNCTION BOX

WH

PM

WH

BK

WARNING:DISCONNECT
POWER BEFORE
SERVICING. W IRING
TO UNIT MUST BE
PROPERLY POLARIZED
AND GROUNDED.

NO

HIGH FIRE
PRESSURE SWITCH

GAS VALVE
(HONEY WELL)

BK

NO

TWO STAGE

YL

BL

YL

SWITCH
2 CIRCUIT
CONNECTOR

HI

24V HUM.

YL

LOW FIRE
PRESSURE

BR

SWITCH ASSEMBLY
HOT
SURFACE
IGNITER

YL

RD

ID BLOWER TWO-STAGE PRESSURE

TO
115 VAC/ 1 /60 HZ
POWER SUPPLY WITH
OVERCURRENT
PROTECTION DEVICE

GND

FIELD GND
FIELD SPLICE
SWITCH (TEMP.)
IGNITER
SWITCH (PRESS.)
OVERCURRENT
PROT. DEVICE

0140F01168-B

SS-GMVC8

www.goodmanmfg.com

Accessories
Model

Description

LPM-06

LP Conversion Kit (Springs & Orifice)

AFE18-60A

Fossil Fuel Kit (must be used in a dual-fuel application with a compatible thermostat)

ASAS

Electronic Air Cleaners (sizes = -10, -11, -12 or -18)

AMU

Media Air Cleaners (sizes = 1620, 2020, 1625 or 2025)

White-Rodgers and Honeywell valves

Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without
notice or without incurring obligations. 2015 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA.

www.goodmanmfg.com

SS-GMVC8

You might also like