You are on page 1of 4

Fp Pipe Reducer Correction Factors

For Cv Valve Coefficients


Technical Bulletin No. 1033
Date: March 1987 Page 1 of 4

The following charts show the Bray Fp factors, the pipe reducer correction factors for Cv coefficients, for the given
reducer/valve size combinations at 10 increments of valve opening 0-90. The first chart is for the "Thin Profile DiscStem" valve style and the second is for the "Thru-Stem Disc" valve style. Note that when there are no pipe reducers; that
is, the pipe inlet and outlet diameters are the same as the valve size, the Fp factor is equal to 1 at all angles of opening.
Fp Factors for Bray "Thin Profile Disc-Stem" Valve Style-Series 20,21
REDUCER/VALVE SIZE
COMBINATIONS
Inle Pipe
Valve
Outlet Pipe
Diameter
Size
Diameter

ANGLE OF OPENING
10

20

30

40

50

60

70

80

90

2
2.5
2.5
3
3
3

2
2
2
2
2
2

2
2
2.5
2
2.5
3

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
1.00
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.97

1.00
0.90
0.97
0.86
0.92
0.92

1.00
0.77
0.91
0.70
0.81
0.82

1.00
0.65
0.84
0.58
0.70
0.71

1.00
0.52
0.74
0.45
0.57
0.58

2.5
3
3

2.5
2.5
2.5

2.5
2.5
3

1.00
1.00
1.00

1.00
1.00
1.00

1.00
0.99
1.00

1.00
0.99
1.00

1.00
0.96
0.99

1.00
0.91
0.97

1.00
0.78
0.92

1.00
0.62
0.85

1.00
0.49
0.75

3
4
4

3
3
3

3
3
4

1.00
1.00
1.00

1.00
1.00
1.00

1.00
0.99
1.00

1.00
0.98
0.99

1.00
0.95
0.98

1.00
0.88
0.95

1.00
0.72
0.87

1.00
0.53
0.72

1.00
0.40
0.59

4
5
5
6
6
6

4
4
4
4
4
4

4
4
5
4
5
6

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
0.99
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.97

1.00
0.89
0.97
0.86
0.92
0.92

1.00
0.75
0.90
0.69
0.80
0.81

1.00
0.55
0.77
0.47
0.60
0.61

1.00
0.42
0.65
0.36
0.47
0.48

5
6
6
8
8
8

5
5
5
5
5
5

5
5
6
5
6
8

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
0.99
1.00

1.00
0.99
1.00
0.97
0.98
0.99

1.00
0.96
0.99
0.93
0.96
0.96

1.00
0.91
0.97
0.85
0.90
0.91

1.00
0.78
0.93
0.67
0.76
0.78

1.00
0.57
0.82
0.46
0.56
0.58

1.00
0.43
0.69
0.33
0.42
0.43

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed
written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers
detailed knowledge and experience with their application.

Fp Pipe Reducer Correction Factors


For Cv Valve Coefficients
Technical Bulletin No. 1033
Date: March 1987 Page 2 of 4

6
8
8
10
10
10

6
6
6
6
6
6

6
6
8
6
8
10

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
0.99
0.98
0.99
0.99

1.00
0.96
0.98
0.94
0.97
0.96

1.00
0.89
0.96
0.86
0.92
0.91

1.00
0.75
0.88
0.70
0.80
0.79

1.00
0.54
0.73
0.48
0.60
0.59

1.00
0.40
0.58
0.35
0.45
0.44

8
10
10
12
12
12

8
8
8
8
8
8

8
8
10
8
10
12

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
1.00
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.97

1.00
0.90
0.97
0.86
0.92
0.93

1.00
0.77
0.91
0.71
0.81
0.82

1.00
0.57
0.79
0.50
0.62
0.64

1.00
0.41
0.64
0.35
0.46
0.48

10
12
12
14
14
14

10
10
10
10
10
10

10
10
12
10
12
14

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
1.00
1.00

1.00
0.99
1.00
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.98

1.00
0.91
0.98
0.87
0.93
0.94

1.00
0.79
0.93
0.72
0.83
0.85

1.00
0.59
0.83
0.51
0.64
0.68

1.00
0.43
0.70
0.36
0.48
0.52

12
14
14
16
16
16

12
12
12
12
12
12

1.00 1.00 1.00 1.00 1.00 1.00


1.00 1.00 1.00 0.99 0.97 0.92
1.00 1.00 1.00 1.00 0.99 0.98
1.00 1.00 0.99 0.98 0.95 0.88
1.00 1.00 1.00 0.99 0.97 0.93
1.00 1.00 1.00 0.99 0.98 0.95
"Thru-Stem Disc" Valve Style Series 30,31,34

1.00
0.81
0.95
0.74
0.84
0.87

1.00
0.62
0.86
0.53
0.66
0.72

1.00
0.45
0.74
0.37
0.49
0.55

12
12
14
12
14
16
Fp Factors for Bray

REDUCER/VALVE SIZE
COMBINATIONS
Inle Pipe
Valve
Outlet Pipe
Diameter
Size
Diameter

ANGLE OF OPENING
10

20

30

40

50

60

70

80

90

2
2.5
2.5
3
3
3

2
2
2
2
2
2

2
2
2.5
2
2.5
3

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
1.00
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.97

1.00
0.92
0.98
0.89
0.94
0.94

1.00
0.87
0.96
0.82
0.90
0.90

1.00
0.79
0.92
0.73
0.83
0.84

1.00
0.72
0.88
0.65
0.76
0.77

2.5
3
3

2.5
2.5
2.5

2.5
2.5
3

1.00
1.00
1.00

1.00
1.00
1.00

1.00
1.00
1.00

1.00
0.99
1.00

1.00
0.97
0.99

1.00
0.92
0.98

1.00
0.84
0.95

1.00
0.74
0.91

1.00
0.66
0.87

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed
written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers
detailed knowledge and experience with their application.

Fp Pipe Reducer Correction Factors


For Cv Valve Coefficients
Technical Bulletin No. 1033
Date: March 1987 Page 3 of 4

3
4
4

3
3
3

3
3
4

1.00
1.00
1.00

1.00
1.00
1.00

1.00
0.99
1.00

1.00
0.98
0.99

1.00
0.95
0.98

1.00
0.89
0.96

1.00
0.75
0.88

1.00
0.64
0.81

1.00
0.55
0.74

4
5
5
6
6
6

4
4
4
4
4
4

4
4
5
4
5
6

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
0.99
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.97

1.00
0.91
0.97
0.87
0.93
0.93

1.00
0.77
0.91
0.70
0.81
0.82

1.00
0.64
0.84
0.57
0.70
0.71

1.00
0.57
0.79
0.50
0.63
0.64

5
6
6
8
8
8

5
5
5
5
5
5

5
5
6
5
6
8

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
0.99
1.00

1.00
0.99
1.00
0.97
0.98
0.99

1.00
0.97
0.99
0.94
0.96
0.97

1.00
0.92
0.98
0.86
0.91
0.92

1.00
0.79
0.93
0.69
0.78
0.79

1.00
0.65
0.87
0.54
0.64
0.66

1.00
0.59
0.82
0.47
0.57
0.59

6
8
8
10
10
10

6
6
6
6
6
6

6
6
8
6
8
10

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
0.99
0.98
0.99
0.99

1.00
0.96
0.98
0.95
0.97
0.97

1.00
0.91
0.96
0.88
0.93
0.92

1.00
0.76
0.89
0.71
0.81
0.80

1.00
0.62
0.79
0.56
0.67
0.66

1.00
0.55
0.73
0.49
0.61
0.60

8
10
10
12
12
12

8
8
8
8
8
8

8
8
10
8
10
12

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
0.99
1.00
0.99
1.00
1.00

1.00
0.98
1.00
0.98
0.99
0.99

1.00
0.96
0.99
0.94
0.97
0.97

1.00
0.91
0.97
0.87
0.93
0.93

1.00
0.78
0.92
10.72
0.82
0.83

1.00
0.64
0.84
0.57
0.69
0.70

1.00
0.58
0.79
0.51
0.63
0.65

10
12
12
14
14
14

10
10
10
10
10
10

10
10
12
10
12
14

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
1.00
1.00

1.00
0.99
1.00
0.98
0.99
0.99

1.00
0.97
0.99
0.95
0.97
0.98

1.00
0.92
0.98
0.88
0.94
0.95

1.00
0.80
0.94
0.74
0.84
0.86

1.00
0.66
0.87
0.58
0.71
0.74

1.00
0.59
0.83
0.51
0.64
0.68

12
14
14
16
16
16

12
12
12
12
12
12

12
12
14
12
14
16

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
1.00
1.00

1.00
0.99
1.00
0.98
0.99
0.99

1.00
0.97
0.99
0.95
0.97
0.98

1.00
0.92
0.98
0.88
0.94
0.95

1.00
0.81
0.95
0.74
0.84
0.88

1.00
0.67
0.89
0.59
0.71
0.77

1.00
0.60
0.85
0.52
0.65
0.70

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed
written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers
detailed knowledge and experience with their application.

Fp Pipe Reducer Correction Factors


For Cv Valve Coefficients
Technical Bulletin No. 1033
Date: March 1987 Page 4 of 4

14
16
16
18
18
18

14
14
14
14
14
14

14
14
16
14
16
18

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
1.00
1.00

1.00
0.99
1.00
0.98
0.99
0.99

1.00
0.97
0.99
0.95
0.98
0.98

1.00
0.93
0.99
0.90
0.95
0.96

1.00
0.83
0.96
0.76
0.86
0.90

1.00
0.70
0.92
0.62
0.74
0.81

1.00
0.64
0.89
0.55
0.68
0.75

16
18
18
20
20
20

16
16
16
16
16
16

16
16
18
16
18
20

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
1.00
1.00

1.00
0.99
1.00
0.98
0.99
0.99

1.00
0.97
1.00
0.96
0.98
0.99

1.00
0.94
0.99
0.90
0.95
0.97

1.00
0.84
0.97
0.77
0.86
0.91

1.00
0.72
0.93
0.63
0.75
0.83

1.00
0.66
0.91
0.56
0.69
0.78

18
20
20
24
24
24

18
18
18
18
18
18

18
18
20
18
20
24

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
1.00
1.00
1.00

1.00
1.00
1.00
0.99
1.00
1.00

1.00
0.99
1.00
0.98
0.99
0.99

1.00
0.98
1.00
0.95
0.97
0.98

1.00
0.94
0.99
0.89
0.93
0.95

1.00
0.85
0.97
0.74
0.81
0.87

1.00
0.74
0.94
0.60
0.70
0.78

1.00
0.68
0.92
0.54
0.63
0.72

20
24
24

20
20
20

20
20
24

1.00
1.00
1.00

1.00
1.00
1.00

1.00
0.99
1.00

1.00
0.98
1.00

1.00
0.96
0.99

1.00
0.91
0.98

1.00
0.78
0.93

1.00
0.65
0.86

1.00
0.58
0.82

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed
written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers
detailed knowledge and experience with their application.