You are on page 1of 4

TP15DD Series

DESCRIPTION

15W Wide Voltage Input DC/DC Converters

The rated output power of TP15DD converters is 15W,the outline dimensions is 50.8*40.6*11.2, 2:1
and 4:1 wide input voltage range, the voltage range is 9V-18V,18V-36V,36V-72V,9V-36V and
18V-72VDC.The accuracy of the converter can reach 1%, it can be widely used in
telecommunications, railway transportation, instrument and etc.

FEATURES
15W output power

2:1&4:1 wide input voltage range

Under input voltage protection

50.8mm*40.6mm*11.2mm standard package

Fixed switching frequency

Over output voltage protection

Operating temperature: -25 to 55

Long-term short circuit protection

Good capability of capacity load

Metal shielding package

RoHS compliant

SELECTION GUIDE
Input Voltage
Part Number
TP15DD12S03
TP15DD12S05
TP15DD12S12
TP15DD12S15
TP15DD12S24
TP15DD12D05
TP15DD12D12
TP15DD12D15
TP15DD24S03
TP15DD24S05
TP15DD24S12
TP15DD24S15
TP15DD24S24
TP15DD24D05
TP15DD24D12
TP15DD24D15
TP15DD48S03
TP15DD48S05
TP15DD48S12
TP15DD48S15
TP15DD48S24
TP15DD48D05
TP15DD48D12
TP15DD48D15
TP15DD24S05W
TP15DD24S12W
TP15DD24S15W
TP15DD24S24W
TP15DD24D05W
TP15DD24D12W
TP15DD24D15W
TP15DD48S05W
TP15DD48S12W
TP15DD48S15W
TP15DD48S24W
TP15DD48D05W
TP15DD48D12W
TP15DD48D15W

Output

voltageVDC)
Rated

Range values

12(2:1)
12(2:1)
12(2:1)
12(2:1)
12(2:1)
12(2:1)
12(2:1)
12(2:1)
24(2:1)
24(2:1)
24(2:1)
24(2:1)
24(2:1)
24(2:1)
24(2:1)
24(2:1)
48(2:1)
48(2:1)
48(2:1)
48(2:1)
48(2:1)
48(2:1)
48(2:1)
48(2:1)
24(4:1)
24(4:1)
24(4:1)
24(4:1)
24(4:1)
24(4:1)
24(4:1)
48(4:1)
48(4:1)
48(4:1)
48(4:1)
48(4:1)
48(4:1)
48(4:1)

9-18
9-18
9-18
9-18
9-18
9-18
9-18
9-18
18-36
18-36
18-36
18-36
18-36
18-36
18-36
18-36
36-72
36-72
36-72
36-72
36-72
36-72
36-72
36-72
9-36
9-36
9-36
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
18-72
18-72
18-72

VoltageVDC)

CurrentA

Efficiency(Typ)
%

3.3
5
12
15
24
5
12
15
3.3
5
12
15
24
5
12
15
3.3
5
12
15
24
5
12
15
5
12
15
24
5
12
15
5
12
15
24
5
12
15

4
3
1.25
1
0.63
1.5
0.63
0.5
4
3
1.25
1
0.63
1.5
0.63
0.5
4
3
1.25
1
0.63
1.5
0.63
0.5
3
1.25
1
0.63
1.5
0.63
0.5
3
1.25
1
0.63
1.5
0.63
0.5

80
82
82
84
84
80
83
85
80
83
85
85
85
83
85
85
80
83
85
85
85
83
85
85
80
82
83
84
81
83
84
80
82
83
85
81
83
84

All specifications typical at TA=25C, nominal input voltage and rated output current unless otherwise specified.

www.gztoppower.com

TEL:086-20-82019000

Email:sales2@gztoppower.com

Page 1 /4

TP15DD Series
GENERAL CHARACTERISTICS
parameter

Test conditions

Isolation voltage

Input to output

Insulation resistance

Input to output

Seismic

10~55Hz

MTBF

MIL-HDBK-217F2

Over-current protection mode

All input range

Min

Typ

Max

500

1500

100M

Units
VDC
Ohm

5 x 105

hrs

Automatic recovery

Cooling

Free air convection

Case material

Metal case

INPUT CHARACTERISTICS
parameter

Test conditions

Min

Typ

Max

Units

Startup voltage

The12V input module(9V-18V)

9.2

9.5

9.8

VDC

Startup voltage

The24V input module(18V-36V)

18

VDC

Startup voltage

The48Vinput module(36V-72V)

36

VDC

Startup voltage

The24V input module(9V-36V)

9.3

VDC

Startup voltage

The48Vinput module(18V-72V)

18

VDC

Under input voltage protection

The12V input module(9V-18V)

8.5

VDC

Under input voltage protection

The24V input module(18V-36V)

17

VDC

Under input voltage protection

The48Vinput module(36V-72V)

35

VDC

Start time

Input rising time from 5%-100%

CTL remote control

CTL remote control add -vin

Turn off

CTL remote control

CTL remote control pending Level control from 12V-40V

Turn on

8.8

20

ms

OUTPUT CHARACTERISTICS
parameter

Test conditions

Voltage accuracy

Io=0.11.0 x Ionom vi=vi rated

Line regulation

ViminViVimax

Min

Typ

Io=0.11.0 x Ionom

Load regulation

ViminViVimax

Max

Units

0.2

0.5

Main Load and auxiliary load differ 25%,the


Auxiliary voltage accuracy

auxiliary circuit of the load with at least 25%, the


main circuit with full load

Ripple and noise

20MHz bandwidth

Over current protection

ViminViVimax

120

output voltage change range

ViminViVimax

10

Transient recovery time

25% load changes

Transient overshoot time

25% load changes

400

us

Switch frequency

ViminViVimax

300

KHz

ENVIRONMENT CHARACTERISTICS
parameter

Test conditions

Min

Environment temperature

industrial-class

-25

Maximum case temperature

industrial-class

Storage temperature

Industry-class/ Military JI&JII class

Relative humidity

No condensation

Max

Units

+55

+85

-40

+105

90

RH(%

0.02

Temperature coefficient


Typ

%/

Module in every environment temperature rating, case temperature under shall not exceed the maximum case temperature level.

www.gztoppower.com

TEL:086-20-82019000

Email:sales2@gztoppower.com

Page 2 /4

TP15DD Series
MECHANICAL DIMENSIONS
50.80
2.54

PIN CONNECTION

45.72

7
10.16

5.08

1
2

10.16

6 (6)
10.16 40.60

bottom view

10.16

7.80

Pin

Single output

Dual output

+Vin

+Vin

-Vin

-Vin

CTL

CTL

TRM

TRM

-Vout

-Vout

+Vout

(6)

Com

+Vout

5.08

11.20

1.20

>4.00

1.00

Unitsmm
Tolerance:0.2mm

MODEL SELECTION

TP

15

D D

24

S 05

W
W:4:1 Wide voltage input range
Output voltage
S: single output

D: Dual output

Input Rated Voltage


Package type
DC-DC
Output rated power
Brand name

RECOMMEND CIRCUIT
Single Output

+vin

Cin

-vin

www.gztoppower.com

TEL:086-20-82019000

+ V0

DC-DC

+
Cout
-V0

Email:sales2@gztoppower.com

Page 3 /4

TP15DD Series
RECOMMEND CIRCUIT
Dual Output
+vin

+V0

Cin

Cout1

DC-DC

COM

Cout2

-vin

-V0

Add input capacitance Cin is helpful to improve the electromagnetic compatibility, recommend Cin use 47 uF-100uF of the electrolytic capacitors.

If the module connect to the digital circuits, please add the CoutCout1Cout2.

If Cout, Cout1, Cout2 value is too high or lower ESR, it will cause the module instable,

The recommended value of Cout, Cout1, Cout2 should be 100 uF/A, the current here means the output current.

Trim application&Trim Resistance


Raise the output Voltage

+Vo

+Vo
Trim(Vadj)
-Vo

Down the output voltage

DC-DC

Trim(Vadj)

DC-DC

-Vo

In dual and triple output modules,this application can just used in the mian road(auxiliary road chage together with the main road)

USING ATTENTIONS


Module will cause irreversible damage when in the state of the input reverse polarity.

Module will cause irreversible damage when in the long-term overload conditions.

Module will cause irreversible damage when out of the maximum input voltage range.

STEMPERATURE DERATING GR

www.gztoppower.com

TEL:086-20-82019000

Email:sales2@gztoppower.com

Page 4 /4