(i)
Calculate the MMF required for the air gap of a machine having
core length = 0.32m, including 4 ducts of 10 mm each; pole
arc=0.19m;slot pitch = 65.4 mm; slot opening = 5mm; air gap length
= 5mm ; flux per pole = 52mWb. Given carters coefficient is 0.18
for opening/gap=1; and is 0.28 for opening/gap= 2.
QP-01
Rev. 0
11-02-16
(b)
(i)
(ii) Calculate the core and window area required for a 1000KVA,
6600/400V, 50Hz, single phase core type transformer. Assume a
maximum flux density of 1.25Wb/m2 and a current density of 2.5
A/mm2, voltage per turn =30V, window space factor is 0.32.
(10)
K2
C314.2
(5)
K3
C314.3