You are on page 1of 26

CONSTRUCTION ESTIMATE CALCULATOR

(BY ENGR. RONALD JOHN R. CAJILLA)


(JUST INPUT THE DATA INSIDE THE YELLOW CELL)
ITEM - I CONCRETING WORKS
A. DETERMINING THE VOLUME OF A CONCRETE
FOOTING
FORMULA:
VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length L (M)
0,60
Enter Width W (M)
0,60
Enter Thickness T (M)
0,25
W
T
0,09
TOTAL VOLUME OF CONCRETE:
Number of Footing Units
10,00
0,90
TOTAL VOLUME OF CONCRETE:
9,00
# OF CEMENT BAGS
0,50
VOL. OF SAND CU.M.
L
0,90
VOL. OF 3/4" GRAVEL CU.M.

M
M
M
CU.M.
Units
CU.M.
BAGS
CU.M.
CU.M.

WALL FOOTING

T
L = LENGTH
FORMULA:

LT = TOTAL LENGTH/PERIMETER
FLOOR SLAB

VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length LT (M)
32,00
Enter Width W (M)
0,30
Enter Thickness T (M)
0,15
1,44
TOTAL VOLUME OF CONCRETE:
13,00
# OF CEMENT BAGS
0,80
VOL. OF SAND CU.M.
1,50
VOL. OF 3/4" GRAVEL CU.M.
FORMULA:

VOLUME = L * W * T
CLASS A CONCRETE MIX
Enter Length L (M)
6,00
Enter
Width
9,00
W
(M)
T
Enter Thickness T (M)
0,10
Enter Concrete Mix Design (CLASS) AA, A,or B
b
7,5
0,5
5,40
TOTAL VOLUME OF CONCRETE:
41,00
# OF CEMENT BAGS
2,70
VOL. OF SAND CU.M.

M
M
M
CU.M.
BAGS
CU.M.
CU.M.

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

M
M
M
1:3:6
1
CU.M.
BAGS
CU.M.

L
VOL. OF 3/4" GRAVEL CU.M.
(BY ENGR. RONALD JOHN R. CAJILLA)

5,40

CU.M.

FLOOR SLAB - BY AREA


FORMULA:

Area
7,5

0,5

CONCRETE COLUMNS
RECTANGULAR

VOLUME = Floor Area* T


CLASS A CONCRETE MIX
T
Enter Floor Area A (SQ.M)
420,00
SQ.M
Enter Thickness T (M)
0,10
M
Enter Concrete Mix Design (CLASS) AA, A,or B
B
1:3:6
42,00
CU.M.
TOTAL VOLUME OF CONCRETE:
315,00
# OF CEMENT BAGS
BAGS
21,00
CU.M.
VOL. OF SAND CU.M.
42,00
CU.M.
VOL. OF 3/4" GRAVEL CU.M.
COLUMN DIMENSIONS:

W1

Width 1
Width 2

0,25
0,25

M
M

W2
FORMULA:

VOLUME = H * W1 * W2
CLASS A CONCRETE MIX
H
Enter Height L (M)
1,22
M
0,08
CU.M.
VOLUME OF CONCRETE FOR EACH COLUME:
Number of Columns Units
10,00
Units
0,76
CU.M.
TOTAL VOLUME OF CONCRETE:
7,00
# OF CEMENT BAGS
BAGS
0,40
CU.M.
VOL. OF SAND CU.M.
0,80
CU.M.
VOL. OF 3/4" GRAVEL CU.M.

CONCRETE COLUMNS
CIRCULAR

COLUMN DIMENSIONS:

D1

Diameter

0,30

AreaCirc

0,07

SQ.M.

FORMULA:

VOLUME = H * AreaCirc
CLASS A CONCRETE MIX
H
Enter Height L (M)
3,00
0,21
VOLUME OF CONCRETE EACH COLUMN:
Number of Columns Units
6,00
1,27
TOTAL VOLUME OF CONCRETE:
12,00
# OF CEMENT BAGS
0,70
VOL. OF SAND CU.M.
1,30
VOL. OF 3/4" GRAVEL CU.M.

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

M
CU.M.
Units
CU.M.
BAGS
CU.M.
CU.M.

(BY ENGR. RONALD JOHN R. CAJILLA)

CONCRETE BEAMS
VOLUME = LT * W * D
CLASS A CONCRETE MIX
EnterTotal Length LT (M)
5,00
M
Enter Width W (M)
0,20
M
Enter Depth D (M)
0,30
M
0,30
CU.M.
TOTAL VOLUME OF CONCRETE:
3,00
BAGS
# OF CEMENT BAGS
0,20 CU.M.
VOL. OF SAND CU.M.
0,30 CU.M.
VOL. OF 3/4" GRAVEL CU.M.
FORMULA:

LT
BEAM DIMENSIONS:

W
CONCRETE STAIRS

Enter Riser Height


Enter Tread Run
Enter Stair Width
Enter # of Steps
Enter Stringer Thickness

TR
RH

0,25

TS

RH (M)
TR (M)
W (M)
N
TS (M)

0,20
0,30
1,20
7,00
0,15

0,45

0,71

TOTAL VOLUME OF CONCRETE:


# OF CEMENT BAGS
VOL. OF SAND CU.M.
VOL. OF 3/4" GRAVEL CU.M.

0,71
7,00
0,40
0,80

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

M
M
M
Steps
M

CU.M.
BAGS
CU.M.
CU.M.

BY: ENGR. RONALD JOHN R. CAJILLA


ITEM - II MASONRY WORKS
A. DETERMINING THE NUMBER OF CONCRETE HOLLOW BLOCKS USED
B. DETERMINING THE NUMBER OF CEMENT & VOLUME OF SAND FOR MORTAR & PLASTERING
Enter Wall Height H (M)
6,00
M
Enter Wall Length L (M)
20,00
M
Enter Area of Window AW (SQ.M.)
2,88
SQ.M
Enter Area of Door AD (SQ.M)
1,47
SQ.M.
Breakage Allowance
5,00
%
%
115,65
TOTAL WALL AREA:
TOTAL NUMBER OF CHB: 1.518,00

SQ.M.
PCS

MORTAR USING 4" CHB


61,00
BAGS
BAGS
5,10 CU.M.
CU.M.
MORTAR USING 6" CHB
118,00
# OF CEMENT BAGS
BAGS
9,80 CU.M.
VOL. OF SCREENED SAND CU.M.
# OF CEMENT
VOL. OF SCREENED SAND

# OF CEMENT
VOL. OF FINE SAND

# OF CEMENT
VOL. OF FINE SAND
RIPRAPING WORKS

W1

PLASTER : 16mm thk Mix: 1:2


One face ofthe wall only
34,00
BAGS
BAGS
1,90 CU.M.
CU.M.
PLASTER : 16mm thk Mix: 1:2
Two faces of the wall
67,00
BAGS
BAGS
3,80 CU.M.
CU.M.

Enter Height H (M)


Enter Width 1 W1 (M)
Enter Width 2 W2 (M)
Enter Length L (M)

2,00
0,30
0,60
20,00

M
M
M
M

Using: Stones ranging from 15 to 25 kgs with atleast


50% of stones weighing more than 20 kgs, &
Class A Mixture
TOTAL SIDE AREA:
TOTAL VOLUME:
VOL. OF BOULDERS CU.M.
# OF CEMENT BAGS
VOL. OF SAND CU.M.

W2

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

0,90
18,00
18,00
47,00
2,60

SQ.M.
CU.M.
CU.M.
BAGS
CU.M.

BY: ENGR. RONALD JOHN R. CAJILLA


ITEM - III STEEL REINFORCEMENT
LENGTH OF REINFORCING BARS FOR CHB IN METERS
VERT. SPACING
(CM)

(M) LENGTH OF
VERTICAL
REIN./SQ.M.

SPACEING LAYER

(M) LENGTH OF
HORIZONTAL
REIN./ SQ.M.

40

2,93

2 Layers

3,300

60

2,13

3 Layers

2,150

80

1,6

4 Layers

vertical spacing

spacing
layer

1,720

DETERMINING THE NUMBER OF BARS USED


Enter Wall Height H (M)
Enter Wall Length L (M)
Enter wall openings
SQ.M
Enter Constant Factor VERTICAL
Enter Constant Factor HORIZONTAL
TOTAL WALL AREA:
# OF VERTICAL BARS USED:
# OF HORIZONTAL BARS USED:
#16 TIE WIRE USED:

3,50
M
10,00
M
1,68
SQ.M.
2,13
60cm
2,15 3 layers
33,32
SQ.M.
12,00 PCS @ 6M
12,00 PCS @ 6M
1,60
Kgs

FOOTING MATTING
Enter Footing Length
Enter Footing Width
Enter # of Bars along L
Enter Number of Bars along W
Enter Number of Footing
Enter Clear Cover

L (M)
W (M)
#
#
#
Cc (M)

0,60
0,60
4,00
4,00
10,00
0,050

M
M
Pcs
Pcs
Units
M

Note: Standard Clear Cover for footing =0.05m to 0.075m

# of Bars
per Side
W

Net. Length along L


Net. Length along W
# OF REIN. BARS USED:
#16 TIE WIRE USED:

Clear
Cover

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

0,50
0,50
8,00
1,30

M
M
LHS
Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


WALL FOOTING REINFORCEMENT
Enter Wall Footing Width W (M)
Enter Wall Footing Total Length LT (M)
Enter Spacing of Tie Bars for Wall footing
(M)
Total # of Ties:
Total # of Horizontal Bars Used:
Overall Total # of Bars used:
#16 TIE WIRE USED:

0,30
32,00
0,40

M
M
M

81,00
12,00
17,00
1,30

PCS
LHS
LHS
Kgs

Tie Bars

LT = TOTAL LENGTH/PERIMETER

RECTANGULAR COLUMN REINFORCEMENT

D1

Clear Cover
for
columns =
0.40m

D2
Enter Column Height
Enter Number of Columns
Enter Reinforcement Bar Diameter required
Enter Column Dimension D1
Enter Column Dimension D2
Enter Number of Vertical Bars

End Hook/ L hookEnter Stirrup bar diameter required

Enter Stirrups Spacing

H (M)
#

(M)
(M)

1,47
10,00

M
Units

12,00
0,25
0,25

mm
M
M

(M)

(M)

4,00

PCS

10,00
0,20

mm
M

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

BY: ENGR. RONALD JOHN R. CAJILLA


0,5
0,2
Use End Hook:
Total length of each bars should be more than or equal to:
Total Number of Vertical Bars @ 6M:
3
Cut Length of each stirrups:
Number of Stirrups per Column:
Total Number of Bars used for stirrups @ 6M :
#16 TIE WIRE USED:

0,200
2,20
20,00

M
M
LHS

0,90
19,00
29,00

M
PCS
LHS

4,40

Kgs

3,50
8,00

M
Units

12,00
0,30

mm
M

6,00

PCS

10,00
0,20

mm
M

CIRCULAR COLUMN REINFORCEMENT


Enter Column Height
Enter Number of Columns
Enter Reinforcement Bar Diameter required
Enter Column Diameter D1

D1

Enter Number of Vertical Bars


Enter Stirrup bar diameter required
Enter Stirrups Spacing

H (M)
#

(M)

(M)

(M)

0,2
Use End Hook:
0,200
Total length of each bars should be more than or equal to:
4,20
48,00
Total Number of Vertical Bars @ 6M:
6 Circular Stirrups
Cut Length of each stirrups:
0,90
Number of Stirrups per Column:
28,50
35,00
Total Number of Bars required for stirrups @ 6M :
7,80
#16 TIE WIRE required:
Spiral Stirrups
Cut Length of each stirrups:
Number of Stirrup Loops per Column:
Total Number of Bars required for stirrups @ 6M :
#16 TIE WIRE required:

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

0,70
28,50
30,00
7,80

M
M
LHS
M
M
LHS
Kgs

M
M
LHS
Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.0 METERS) ONE BAY

L(beam to beam)

Enter Beam to Beam Length


Enter Beam Width
Enter Beam Depth
Enter Column Width

Bottom Bars

M
M
M
M
Units

16,00

mm

Web Bars
12,00
Note: put "0" zero if web bars not applicable
2
Bottom Bars
16,00

mm

Top Bars
Web Bars

5,00
0,20
0,30
0,30

# of Non# of Bars
Continuous Size of Bars
Continuous
Bars

Top Bars

L (M)
W (M)
D (M)
Cw(M)

Enter Stirrup Bars Diameter required:


Enter Stirrup Spacing:

mm

10,00
0,20

mm
M

3,00
-

PCS
PCS

PCS

2,00
-

PCS
PCS

L = Span
L/4

0.15L

Column
Width

TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars
# of 6m Length Deformed Bars required as Non-Continuous Bars
WEB BARS
# of 6m Length Deformed Bars required as Web Bars
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars
# of 6m Length Deformed Bars required as Non-Continuous Bars

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 16mm bars used as main bars
Number of 12mm bars used as web bars
Number of 10mm bars used as stirrups
#16 TIE WIRE USED:
BEAM REINFORCEMENT (TWO BAYS) CONTINUOUS BEAM
Enter Beam Length 1 L1 (M)
Enter Beam Length 2 L2 (M)
Enter Beam Width W (M)
Enter Beam Depth
D (M)
L2
L1
Enter Column Width Max Cw(M)

Top Bars
Web Bars

Bottom Bars

5,00
5,00
0,20
0,30
0,30

M
M
M
M
M
Units

12,00

mm

Web Bars
10,00
Note: put "0" zero if web bars not applicable
2
1
Bottom Bars
12,00

mm

Enter Stirrup Bars Diameter required:


Enter Stirrup Spacing:

L = Span1
L/4

PCS
PCS
PCS
Kgs

# of Non# of Bars
Continuous Size of Bars
Continuous
Bars

Top Bars

5,00
6,00
0,80

mm

10,00
0,20

mm
M

4,00
2,00

PCS
PCS

PCS

L = Span2
L/4

0.15 L
0.15 L

Column
Width

TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars
# of 6m Length Deformed Bars required as Non-Continuous Bars
WEB BARS
# of 6m Length Deformed Bars required as Web Bars

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

BOTTOM BARS
# of 6m Length Deformed Bars used as Continuous Bars
# of 6m Length Deformed Bars required as Non-Continuous Bars

4,00
2,00

PCS
PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 12mm bars required as main bars
Number of 10mm bars required as web bars
Number of 10mm bars required as stirrups
#16 TIE WIRE USED:

12,00
2,00
2,20

PCS
PCS
PCS
Kgs

ONE WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB


BAR SPACING IN CM.
10,000
12,500
15,000
17,500
20,000
22,200
25,000

NUMBER OF STEEL BARS PER SQUARE METER

TIES (KGS)

3,764
3,062
2,584
2,232
1,980
1,786
1,627

0,474
0,316
0,228
0,168
0,132
0,110
0,089

Enter Length
Enter Width
Enter Bar Spacing

L (M)
W (M)
cm

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

9,00
7,00
22,20

M
M
CM

# of Steel Bar Constant factor


c
# of Ties #16 Constant factor
c
# OF STEEL BARS required PCS @ 6M
# OF #16 TIE WIRE required
KGS
BY: ENGR. RONALD JOHN R. CAJILLA

1,786
0,110
113,00
7,00

PCS
KGS

TWO WAY SLAB

QUANTITY OF REINFORCING STEEL BARS IN A ONEWAY REINFORCED CONCRETE SLAB


BAR SPACING IN CM.
10,000
12,500
15,000
17,500
20,000
22,200
25,000

NUMBER OF STEEL BARS PER SQUARE METER

TIES (KGS)

4,369
3,603
3,221
2,647
2,360
2,168
1,977

0,592
0,416
0,350
0,247
0,174
0,168
0,142

Enter Length
Enter Width
Enter Bar Spacing

# of Steel Bar Constant factor

L (M)
W (M)
cm

9,00
7,00
25,00

1,977

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

M
M
CM

# of Ties #16 Constant factor


c
# OF STEEL BARS required PCS @ 6M
# OF #16 TIE WIRE required
KGS

0,142
125,00
9,00

PCS
KGS

9,00
7,00
40,00
40,00

M
M
CM
CM

# OF STEEL BARS USED PARALLEL TO L PCS @ 6M


# OF STEEL BARS USED PARALLEL TO W PCS @ 6M
# OF #16 TIE WIRE required
KGS

31,00
30,00
6,00

PCS
PCS
KGS

Enter Riser Height


Enter Tread Run
Enter Stair Width
Enter # of Steps
RH Enter Stringer Thickness

0,20
0,30
1,00
10,00
0,15
0,36

M
M
M
Steps
M
0,66

BY: ENGR. RONALD JOHN R. CAJILLA

REINFORCED GROUND SLAB (BARS SPACING MORE THAN 25CM)


Enter Length
Enter Width
Enter Bar Spacing along W
Enter Bar Spacing along L

L (M)
W (M)
cm
cm

CONCRETE STAIRS

TR

RH (M)
TR (M)
W (M)
N
TS (M)
0,30

Enter Spacing (M)

0,30
Enter Spacing (M)

Enter Steps Lateral Bar diameter (mm)

0,30

12

Enter Stringer Lateral Bar diameter (mm)

TS

16

Enter Spacing (M)

0,30
Enter Spacing (M)

0,30

Enter Steps Lateral Bar diameter (mm)

12

Enter Stringer Horizontal Bar diameter (mm)

12
Number of 12 mm Lateral Bars required @ Steps
Number of 12 mm Horizontal Bars required @ Steps
Number of 16 mm Lateral Bars required @ Stringer
Number of 12 mm Horizontal Bars required @ Stringer
# OF #16 TIE WIRE USED
NOTES:

PCS @ 6M
PCS @ 6M
PCS @ 6M
PCS @ 6M
KGS

5,00
5,00
4,00
2,00
1,00

DOWELS FOR LATERAL BARS ARE ALREADY INCLUDED IN THE ESTIMATES


FOR STAIRS LANDINGS YOU MAY USE THE SLAB REINFORCEMENT CALCULATOR

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

PCS
PCS
PCS
PCS
KGS

BY: ENGR. RONALD JOHN R. CAJILLA

CONCRETE CANAL
TOP OPENING WIDTH
Stiffener
(M)
(M)
(M)
(M)
(M)
(M)

100,00
0,80
0,50
0,30
0,50
0,15

Enter # of layers of CHB used (1 Side)

Layer

3,00

layers

Enter Size of CHB required

4"= 0.10,
6" = 0.15

0,10
10

M
%

CANAL TOTAL HEIGHT

Enter Canal Total Length


Enter Canal Total Height
Enter Top Opening Width

BOTTOM
OPENING
WIDTH

Enter Bottom Opening width


Enter Canal Flooring Bottom Width
Enter Canal Flooring Thickness

TCF

CHB Breakage % allowance


Calc. U bar length

CANAL
FLOORING
BOTTOM
WIDTH
CONCRETING
Canal Flooring
Canal Top Stiffener

%
2,45

PCS
Enter # of Horizonal Bars for flooring
PCS
Enter U bar spacing
(M)
7,5
Enter Concrete Mix Design (CLASS) A or B
Total Volume
7,50
cu.m.
Total Volume
1,00
cu.m.
# of Bags cement
Volume of Sand
Volume of 3/4 Gravel

Enter # of Horizonal Barsfor Walling (2 sides)

4,00
3,00
0,60
0,5
B
56,25
9,00
66,00
29,13
7,50

M
M
M
M
M
M

PCS
PCS
M
1
1:3:6
28,13
1,00
BAGS
CU.M.
CU.M.

MASONRY
# of CHB used
550,00
PCS
AREA
120
MORTAR USING 4" CHB
63,00
BAGS
# OF CEMENT BAGS
5,30 CU.M.
VOL. OF SCREENED SAND CU.M.
MORTAR USING 6" CHB
122,00
# OF CEMENT BAGS
BAGS
10,20
VOL. OF SCREENED SAND CU.M.
CU.M.
PLASTER : 16mm thk Mix: 1:2

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

One face ofthe wall only


35,00
BAGS
# OF CEMENT BAGS
2,00 CU.M.
VOL. OF FINE SAND CU.M.
BY: ENGR. RONALD JOHN R. CAJILLA
REINFORCEMENTS
# of Horizontal Bars Used at CHB Wall
# of Horizontal Bars Used at Flooring
# U Bars
# Bars Used for U Bars

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

73,00 PCS @ 6M
55,00 PCS @ 6M
168,00
PCS
69,00 PCS @ 6M

BY: ENGR. RONALD JOHN R. CAJILLA


CARPENTRY WORKS
Determining the total board foot of a lumber.
Enter Number of pieces
Enter lumber Dimension

#
W1(IN)
W2(IN)
L(FT)

100,00
2,00
4,00
12,00

PCS
inches
inches
feet (ft)

Bd.ft.

800,00

BD.FT

Enter Number of pieces


Enter lumber Dimension

#
D1(IN)
L(FT)

1,00
28,00
20,00

PCS
inches
feet (ft)

TOTAL # OF LUMBER IN BD.FT

Bd.ft.

720,00

BD.FT

Bd.ft.
W1 (in)
2

720
W2 (in)
4

L (ft)
10

PCS

108,00

PCS

L
TOTAL # OF LUMBER IN BD.FT
W2
W1
Determining the total board foot of a round log
FORMULA:

(D - 4) x L
16

Determining the total lengths or pcs of a certain lumber from Bd.ft.

Enter total Bd.ft :


Enter desired lumber dimension :

TOTAL # OF LUMBER IN PIECES/LENGTHS


W2
W1

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

BY: ENGR. RONALD JOHN R. CAJILLA


NUMBER OF BOARD FOOT OF STUDS & NAILING JOIST PER SQUARE METER
SPACING IN CENTIMETER (CENTER TO CENTER)
Lumber size in
inches
30 x 30
30 x 60
40 x 40
40 x 60
60 x 60
1x2
4,103
3,147
3,189
2,686
2,268
2x2
8,198
6,293
6,379
5,373
4,594
2x3
12,284
9,440
9,569
8,060
6,898
2x4
16,414
12,592
12,758
10,746
9,195

L
Enter Length of Wall/Ceilling/Flooring
Enter Height of Wall/Ceilling/Flooring
Enter Constant Factor
# OF BD.FT OF STUDS & NAILING JOIST USED:
Enter total Bd.ft :
Enter desired lumber dimension :
TOTAL # OF LUMBER IN PIECES/LENGTHS

L (M)
H (M)
C
BD.FT

9,00
3,00
6,898
186,25

BD.FT.

Bd.ft.
W1 (in)
2
PCS

186,25
W2 (in)
3
47,00

L (ft)
8
PCS

USING 1/4" ORDINARY PLYWOOD or 4' x 8' HARDIFLEX BOARD


TOTAL # OF 4'X 8' ORDINARY PLYWOOD USED (ONE SIDE) SHTS
10
TOTAL # OF 4'X 8' ORDINARY PLYWOOD USED (TWO SIDES) SHTS
19
# OF 1" CWNails Used for Boards (ONE SIDE)
# OF 1" CWNails Used for Boards (TWO SIDES)
# OF 2 1/2" CWNails Used for Joining the Studs together

KGS
KGS
KGS

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

0,6
1,1
1,4

M
M

Sheets
Sheets
KGS
KGS
KGS

BY: ENGR. RONALD JOHN R. CAJILLA


ROOFING WORKS

Side Lapping
Effective Width

2 1/2
0,60

End Lapping

1 1/2
0,70

25cm - 30 cm

Ls
Span

Projection (Bulada)

Pitch

12

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

BY: ENGR. RONALD JOHN R. CAJILLA


DETERMINING THE DESIRABLE NUMBER OF SHEETS IF USING MORE THAN ONE SHEET
Rafter L1 3,231099
Enter Span (Ls)
3,00
M
Angle 0,422793
Enter Height (H)
1,20
M
H2
0,40 Enter Projection Width (Bulada)
1,00
M
Rafter L2 1,076766
# of pulins
8,00
Total Length of Rafter
4,31
M
USING ONLY TWO SHEETS
Roofing Length
4,38
Total Roofing Net Length
4,38
M
1
2,40
Enter Roof Sheet Length 1
FT
8
2,10
Enter Roof Sheet Length 2
FT
8
2
Overlap
0,42
M
1,37
OK Roof Sheet combination

M
M
M
M
M
FT
FT
FT

USING THREE SHEETS


Total Roofing Net Length
4,38
M
M
Enter Roof Sheet Length 1
FT
8
FT
2
Enter Roof Sheet Length 2
FT
8
FT
Enter Roof Sheet Length 3
FT
8
FT
3
Overlap
1,41
M
4,62
FT
OK Roof Sheet combination
But not economical, cost you more money!
End Lapping must not be more than 2 ft
DETERMINING THE NUMBER OF ROOF SHEETS
Roofing Length1

4,38
2,40
2,10
2,10

Side Lapping
2 1/2
Effective Width
0,60
Enter Roofing total with
11,00
M
Total Roof Width
Enter Effective Width
0,70
M
USING ONLY TWO SHEETS
Number of the 1st Roof sheet used @ 8 feet long at one side only
16
Number of the 2nd Roof sheet used @ 8 feet long at one side only
16
Number of Umbrella Nails/Tekscrews
5

1 1/2
0,70
M
M
Sheets
Sheets
KGS

Note: Must multiply by two if the other side of the roof is similar
USING THREE SHEETS
Number of the 1st Roof sheet used @ 8 feet long at one side only
16
Number of the 2nd Roof sheet used @ 8 feet long at one side only
16
Number of the 3rd Roof sheet used @ 8 feet long at one side only
16
Number of Umbrella Nails/Tekscrews
8
Not recommended, cost you more money!
Note: Must multiply by two if the other side of the roof is similar

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

Sheets
Sheets
Sheets
KGS

Roof Width

BY: ENGR. RONALD JOHN R. CAJILLA

Roof Width

ROOF ACCESSORIES

Enter Total Covered Length


Enter Effective Length
Number of Roof Accessories Used

11,00
2,20
5

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

M
M
PCS

BY: ENGR. RONALD JOHN R. CAJILLA


TILING WORKS
Enter Wall or Floor Area
Enter Breakage Allowance (5 - 10%)

48,00
5,00

SQ.M.
%

Tile Size
# of PCS
Inches
cm
per Sq.m.
3x3
7.5 x 7.5
8.962,00
4x4
10 x 10
5.040,00
4 1/4 x 4 1/4 10.6 x 10.6 4.456,00
4x8
10 x 20
2.520,00
6x6
15 x 15
2.240,00
6x8
15 x 20
1.680,00
6 x 12
15 x 30
1.120,00
8x8
20 x 20
1.260,00
8 x 12
20 x 30
840,00
8 x 16
20 x 40
630,00
10 x 16
25 x 25
807,00
12 x 12
30 x 30
560,00
12 x 24
30 x 60
281,00
16 x 16
40 x 40
315,00
20 x 20
50 x 50
202,00
24 x 24
60 x 60
141,00
Cement Mortar
White Cement
Adhesive

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

5,00
24,00
6,00

BAGS
KGS
BAGS

BY: ENGR. RONALD JOHN R. CAJILLA


PAINTING WORKS
Enter Wall Area

Unit Conversion:1 Gallon = 4 Liters

Simplified Construction Estimate


Table 10-6 Kinds of Paint, Uses and Area Coverage
PRIMERS
KIND OF PAINT
1. Interior
Primer &
Sealer

USES

THINING

DRYING TIME COVERAGE/Gal

For interior
Paint Thinner
wood surfaces

2 hrs, allow
overnight b4 25 to 30 sq.m.
recoating

2. Exterior
For exterior
Paint Thinner
Wood Primer wood surfaces

6 hrs, allow
overnight b4 30 to 40 sq.m.
recoating

3. Red Oxide
Primer

4. Red Lead
Primer

5. Epoxy
Primer

Enter Coverage
Enter # of Coats
Number of Gallons

Primer for
ferrous and
Paint Thinner
3 Hours
35 to 40 sq.m.
non-ferrous
materials
Rust
preventive
Paint Thinner
3 Hours
30 to 40 sq.m.
primer for
ferrous
surfaces
For Steel,
6 hrs, allow
Aluminum,
Epoxy Reducer overnight b4 30 to 40 sq.m.
Galvanized
recoating
iron

WATER BASE MASONRY PAINT


KIND OF PAINT
1. Acrylic Latex
Paint

2. Acrylic SemiGloss Latex

3. Acrylic
Gloss Latex

USES
Exterior &
Interior
masonry
surfaces
Exterior &
Interior
masonry
surfaces
Exterior &
Interior
masonry
surfaces

For furniture,
cabinets,
doors,
windows,
4. Latex HiGloss Enamel tools, toys,
wrought iron,
& primed
metals
5. Tinting
Colors

Acrylic colors

THINING

DRYING TIME COVERAGE/Gal

1/2 lts/ 4 lts


water

30 minutes
allow 6 hrs b4 30 to 40 sq.m.
recoat

Water

30 minutes
allow 6 hrs b4 30 to 40 sq.m.
recoat

Water

30 minutes
allow 6 hrs b4 30 to 40 sq.m.
recoat

Usse as is

1 Hour. Allow
4 hrs before 30 to 40 sq.m.
recoating

water

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

27,00 SQ.M.
Coverage/
25,00
Gal
2,00
Coats
3,00
Gals

ROOF PAINT
KIND OF PAINT

USES

for G.I. Shts,


asbestos
1. All weather
bricks
acylic roof
concrete and
shield
stucco

THINING

water

G.I. roofs and


other metal
2. Davies Roof
such as
Paint Thinner
paint
aluminum and
steel

DRYING TIME COVERAGE/Gal


4 hrs. allow
overnight
before
recoating

40 to 50 sq.m.

6 hrs. allow
overnight
before
recoating

30 to 40 sq.m.

ENAMEL AND GLOSS PAINT


KIND OF PAINT

USES

THINING

DRYING TIME COVERAGE/Gal

for exterior &


5 hrs. allow 8
interior wood
1. Quick
Paint Thinner hrs. before 30 to 40 sq.m.
Drying Enamel and metal
recoating
surface
6 hrs. allow
overnight
before
recoating
3 hrs. allow
overnight
before
recoating

2. Interior
semi-Gloss
Enamel

Interior wood
and metal
Paint Thinner
surfaces

3. Flat wall
Enamel

for interior
Paint Thinner
wall & ceilings

4. Exterior
Gloss paint

for exterrior
wood and
6 hrs. allow 48
Paint Thinner hrs. before 30 to 35 sq.m.
properly
primed metal
recoating
surfaces

5. Tinting
Colors

25 to 30 sq.m.

40 to 50 sq.m.

Oil Base
tinting color

VARNISHING
KIND OF PAINT

1. Valspar or
Spar Varnish

USES

THINING

for floors,
sidings
Paint Thinner
furnitures,
deck of boats

DRYING TIME COVERAGE/Gal

24 hours

40 to 50 sq.m.

for interior
new wood
2. Hi-solid furnitures and
sanding sealer
fixtures,
cabinet,
doors, etc.

Lacquer
Thinner

10 minutes.
Allow 30
40 to 50 sq.m.
minutes
before recoat

for interior
new wood
furnitures,
door panelling
and trim.

Lacquer
Thinner

Allow 30
minutes
30 to 40 sq.m.
before recoat

3. Hi-solid
clear gloss
Lacquer

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

4. Hi-solid
Semi-gloss
Lacquer

for interior
new wood
furnitures,
cabinets,
doors, shelves,
etc

Lacquer
Thinner

Allow 30
minutes
30 to 40 sq.m.
before recoat

5. Hi-solid
dead flat
Lacquer

for interior
wood
furniture,
cabinets, door
jambs, trim
panelling, etc.

Lacquer
Thinner

Allow 30
minutes
30 to 40 sq.m.
before recoat

for furnitures,
cabinets,
6. Water white
doors, panel
gloss Lacquer
and interior
walls

Lacquer
Thinner

Allow 30
30 to 40 sq.m.
minutes
before recoat

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

BY: ENGR. RONALD JOHN R. CAJILLA


FORMS
DETERMINING THE TOTAL MATERIALS USED FOR SQUARES & RECTANGULAR COLUMN FORMS

4' OR 2.4M

Column Height

Enter Column Height


Column Dimension A
Column Dimension B
Enter Number of Columns

M
1,22
M
0,25
M
0,25
Units
4,00
1,20
11,52
Note: One form per column - (Resusable form)
Total # of Bd.ft of frame required:
118,68
Bd.ft
Enter desired lumber dimension : W1 (in)
W2 (in)
L (ft)
2
3
8
Total Number of Lumber:
30,00
PCS
Total Number of Plywood required:
4,00 Sheet(s)
Total Number of #2 1/2 CWNails:
1,00
KGS
Total Number of #1 Finishing Nails:
0,40
Kgs

DETERMINING THE TOTAL MATERIALS USED FOR BEAMS & GIRDER FORMS

Total Beam Length

Enter Beam Length


Beam Dimension D
Beam Dimension B
Enter Number of Beams

M
M
M
Units
0,90

7,00
0,30
0,20
4,00
25,20

Total # of Bd.ft of frame required:


W1 (in)
2
Total Number of Lumber:
Total Number of Plywood required:
Total Number of #2 1/2 CWNails:
Total Number of #1 Finishing Nails:

252,00
W2 (in)
3
63,00
9,00
2,10
0,90

Bd.ft
L (ft)
8
PCS
Sheet(s)
KGS
Kgs

BY: ENGR. RONALD JOHN R. CAJILLA


SCAFFOLDINGS
PARTS OF SCAFFOLDINGS
1. Vertical Support
2. Base of Vertical Support
3. Horizontal Member
4. Diagonal Braces
5. Block and Wedges
6. Nails & Bolts

BY: ENGR. RONALD JOHN R. CAJILLA


COLUMN
Enter Column Height
M
Enter # of Columns
Units
Total Column Height:
30,00

3,00
10,00
M. Ht.

BEAM
Enter Beam Length
M
Enter # of Beams
Units
Total Beam Length:
21,00

FLOORING
Enter Floor Area SQ.M.

3,50
6,00
M. Ht.

80,00

QUANTITY OF LUMBER FOR SCAFFOLDING OR STAGING


Column
Beam
Lumber
Flooring
Size
Vertical Horizontal Brace
Vertical Horizontal
141,00
630,00
351,00
84,00
98,70
488,00
2" x 2"
210,00
950,10
525,00
126,00
147,00
728,00
2" x 3"
280,50 1.267,50
700,50
168,00
196,35
968,00
2" x 4"
Enter total # of Bd.ft of Lumber required:
W1 (in)
2
Total Number of Lumber:
Total Number of #4 CWNails:

224,40
W2 (in)
4
43,00
22,00

Bd.ft
L (ft)
8
PCS
KGS

You might also like