You are on page 1of 10

CONSTRUCTION CROSS-SECTION DRAWINGS AND GUIDE SPECIFICATIONS

FOR CAMBRIDGE INTERLOCKING PAVINGSTONES


Index of Drawings
NO.

DESCRIPTION

NO.

DESCRIPTION

19

Fountain

Patio/Sidewalk/Plaza On
Compacted Aggregate Base

20

Roof Deck Over Habitable Space


Roof Deck Over Uninhabited Space

Patio/Sidewalk/Plaza On Concrete Base

21

03

22

04

Street/Parking Lot/Residential Driveway


Overlay On Existing Concrete Pavement

Parking Garage Over Uninhabited Space


Expansion Joint

23

05

Street/Parking Lot/Residential Driveway


Overlay On Existing Asphalt Pavement

Parking Garage Over Inhabited/


Uninhabited Space Drain

24

06

Heated Sidewalk/Driveway

Parking Garage Over Inhabited Space


Expansion Joint

07

Interior Concrete Base

25

Bridge Deck

08

Steps

26

Gas Station On Cement Treated Base

09

Street/Parking Lot On
Compacted Gravel Base

27

Port/Industrial/Airfield Pavement With


Cement Treated Base

Concrete Curb And Gutter

28

11

Crosswalk On Compacted Aggregate Base

Port/Industrial Pavement On Existing


Asphalt Or Concrete

12

Crosswalk On Concrete Base

29

Airfield Pavement With Cement Treated


Or Asphalt Base

13

Crosswalk On Asphalt Or
Cement Treated Base

30

Airfield Pavement On Existing


Asphalt Or Concrete

14

Utility Structure

31

15

Utility Structure Value Box/Pull Box/


Lamphole

Turfstone Firelane/Driveway/
Intermittent Parking

32

Turfstone Slope Protection

Catch Basin

33

Turfstone Riparian Stabilization

17

Tree Pit Non-Compacted Root Zone

34

Ditch Liner For Intermittent Flows

18

Slope Protection

35

Turfstone Boat Ramp

01
02

10

Residential Driveway With Concrete Edges

16

Cambridge Pavers, Inc. PO Box 157 Lyndhurst, NJ 07071.0157


Order/Dispatch:
Fax 201.933.2230

Phone:
201.933.5000

Administration Fax:
201.933.5532

Find Us Online:
www.cambridgepavers.com

CONCRETE CURB SET 1/4" (70 MM)


BELOW TOP OF CAMBRIDGE PAVERS AND CONTROL
JOINTS @ 15' (5 M) OC
CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
COMPACTED AGGREGATE BASE
6" (150 MM) MIN DEPTH
GEOTEXTILE AS REQUIRED
TURN UP AT SIDES TO COVER BASE

CAMBRIDGE-01

DRAWING NO.

COMPACTED SUBGRADE
12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER
TURN UP AT CURB (DO NOT COVER TOP OF BASE)
NOTES:
1. THICKNESS OF AGGREGATE BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE.
COLDER CLIMATES MAY REQUIRE THICKER BASES.
2. CAMBRIDGE PAVERS SHOULD BE PLACED ON A CEMENT TREATED BASE IF SOIL IS EXTREMELY
WEAK OR CONSTANTLY SATURATED. PAVERS CAN BE OVERLAID OR INLAID ON EXISTING
ASPHALT OR CONCRETE DRIVEWAYS.
PLASTIC, STEEL, ALUMINUM OR PRECAST CONCRETE EDGING MAY BE USED.
3.

RESIDENTIAL DRIVEWAY WITH


CONCRETE EDGES

MIN 6" WIDE x 12" DEEP


(150 MM x 300 MM) CONCRETE CURB
SET 1/4" (7 MM) BELOW TOP OF PAVERS
AND CONTROL JOINTS @ 15' (5 M) OC
CAMBRIDGE PAVERS
2 3/8" (60 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
12" (300 MM) WIDE GEOTEXTILE ALONG PERIMETER
TURN UP AT CURB (DO NOT COVER TOP OF BASE)
CONCRETE / ASPHALT BASE
4" (100 MM) MIN. THICKNESS FOR CONCRETE
3" (75 MM) MIN. THICKNESS FOR ASPHALT

COMPACTED SUBGRADE

CAMBRIDGE-03

DRAWING NO.

2" (50 MM) DIA. DRAIN HOLE FILLED WITH PEA GRAVEL
LOCATE AT LOWEST ELEVATIONS
NOTE:
1. THICKNESS OF BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE.
COLDER CLIMATES MAY REQUIRE THICKER BASES.

PATIO / SIDEWALK / PLAZA


ON CONCRETE BASE

CONCRETE CURB
SET 1/4" (7 MM) BELOW TOP OF PAVERS
AND CONTROL JOINTS @ 15' (5 M) OC

CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS

1" TO 1 1/2"
(25-40 MM) BEDDING SAND

COMPACTED AGGREGATE BASE


4" (100 MM) MIN. THICKNESS

COMPACTED SOIL SUBGRADE

EXISTING BASE

EXISTING SOIL SUBGRADE

1. DRAIN BEDDING SAND OF EXCESS MOISTURE THROUGH PAVEMENT AT LOWEST POINT OR


AT CATCH BASIN(S). SEE DRAWING NO. CAMBRIDGE-03.

STREET/PARKING LOT/RESIDENTIAL DRIVEWAY


OVERLAY ON EXISTING CONCRETE PAVEMENT

CAMBRIDGE-02

DRAWING NO.

CAMBRIDGE-04

DRAWING NO.

EXISTING CONCRETE PAVEMENT

GEOTEXTILE

APPROX. 1" TO 1 1/2"


(25-40 MM) BEDDING SAND

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
(2 3/8" (60 MM) MIN. THICKNESS
FOR RESIDENTIAL DRIVEWAY)

EXISTING CONCRETE CURB

PATIO / SIDEWALK / PLAZA


ON COMPACTED AGGREGATE BASE

NOTE:
1. THICKNESS OF BASE WILL VARY WITH SUBGRADE CONDITIONS AND CLIMATE.
COLDER CLIMATES MAY REQUIRE THICKER BASES.

NOTE:

VARIES

NOTE:

CONCRETE CURB AND FOUNDATION


PER LOCAL STANDARDS
CAMBRIDGE PAVER 3 1/8" (80 MM) MIN.
THICKNESS. 2 3/8" (60 MM) MIN. THICKNESS
FOR RESIDENTIAL DRIVEWAY
1"-1 1/2" (25-40 MM) BEDDING SAND

NOTE:

HEATED SIDEWALK / DRIVEWAY

CONCRETE FOOTER
CONCRETE BASE FOR STEPS

CONCRETE CURB

GEOTEXTILE TURN UP AT CURB

CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS

1 1/2" (40 MM) BEDDING SAND

ELECTRIC HEAT TRACING OR FLEXIBLE


HOSE LAYOUT DETERMINED BY
MANUFACTURER
CONCRETE BASE 4" (200 MM) MIN.
THICKNESS OR COMPACTED AGGREGATE
BASE 6" (150 MM) MIN. THICKNESS

COMPACTED SOIL SUBGRADE

CAMBRIDGE-06

ADHESIVE AT JOINTS AND BOTTOMS

CAMBRIDGE-08

DRAWING NO.

6"-7"
(150-175 MM)
RISE

CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS
SLOPE TO DRAIN

1/4" (7 MM) NOSE

1. USE OF MORTAR IS NOT RECOMMENDED IN PLACE OF ADHESIVE.

STEPS WITH CAMBRIDGE PAVERS

DRAWING NO.

AGGREGATE SUB-BASE AS REQUIRED


UNDER CONCRETE
NOTES:
1. HEATED ASSEMBLIES CAN BE PLACED ON A CEMENT TREATED BASE OR COMPACTED
GRAVEL.
2. ON CONCRETE BASE, PROVIDE PEA GRAVEL-FILLED WEEP HOLE(S) AT LOWEST POINT(S).
COVER TOP OF HOLE WITH GEOTEXTILE.
ON AN AGGREGATE BASE, GEOTEXTILE IS ONLY REQUIRED ALONG THE CURB.
FLEXIBLE HOSE CAN BE PLACED IN TOP LAYER OF AGGREGATE BASE.
3.
4.

VARIES

GEOTEXTILE
EXISTING ASPHALT PAVEMENT
(OR CONCRETE)

EXISTING AGGREGATE BASE


EXISTING SOIL SUBGRADE
2" (50MM) DIA. DRAIN HOLE, FILL WITH
PEA GRAVEL. LOCATE AT LOWEST
ELEVATIONS.
1. DRAIN BEDDING SAND OF EXCESS MOISTURE THROUGH PAVEMENT AT LOWEST POINTS
AS SHOWN OR AT CATCH BASIN(S).

CAMBRIDGE-05

DRAWING NO.

CAMBRIDGE-07

DRAWING NO.

EXISTING CONCRETE FLOOR

GEOTEXTILE AT EDGES & OVER JOINTS

1" (25 MM) BEDDING SAND

CAMBRIDGE PAVER WITH SEALER


2 3/8" (60 MM) MIN. THICKNESS

DOORS, WINDOWS, OR WALLS


ON CONCRETE FOUNDATION

STREET/PARKING LOT/RESIDENTIAL DRIVEWAY


OVERLAY ON EXISTING ASPHALT PAVEMENT

INTERIOR
CONCRETE BASE

6
(150
MIN

VARIES

STREET / PARKING LOT


ON COMPACTED GRAVEL BASE

CONCRETE CURB AND FOUNDATION


PER LOCAL STANDARDS
CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2" (25-40 MM) BEDDING
SAND
12" (300 MM) WIDE GEOTEXTILE ALONG
PERIMETER TURN UP AT CURB

WALK / GRASS

CONCRETE CURB AND GUTTER


PER LOCAL STANDARDS
WITH 90 DEGREE FACE
CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS

12" (300 MM) WIDE GEOTEXTILE


ALONG PERIMETER TURN UP
AGAINST CURB

CAMBRIDGE-10

DRAWING NO.

GEOTEXTILE AS REQUIRED

COMPACTED SOIL SUBGRADE

1" TO 1 1/2"
(25-40 MM) BEDDING SAND

1. DRAIN MAY BE NECESSARY IN SOIL SUBGRADE.

EXISTING ASPHALT PAVEMENT


SAW-CUT PAVEMENT
SEAL JOINT

CONCRETE CURB MIN. 12" (300 MM)


WIDE x 12" (300 MM) DEEP
CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS

1" TO 1 1/2"
(25-40 MM) BEDDING SAND
GEOTEXTILE

CONCRETE BASE
WIRE WELDED FABRIC OR STEEL REBAR AS REQUIRED

COMPACTED SOIL SUBGRADE

CROSSWALK ON CONCRETE BASE

CAMBRIDGE-12

DRAWING NO.

AGGREGATE SUB-BASE AS REQUIRED


8"
2" (50 MM) DIA. DRAIN HOLE
(200
LOCATE AT LOWEST ELEVATIONS
MI
FILL WITH PEA GRAVEL
NOTES:
1. BASE THICKNESS AND REINFORCING VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE CONDITIONS.
2. CONCRETE BASE MINIMUM 2% SLOPE FROM CENTERLINE TO CURB.
3. DO NOT USE DRAIN HOLES TO SUBGRADE WHEN WATER TABLE IS LESS THAN 2' (0.6 M) FROM
TOP OF SUBGRADE. DRAIN TO CATCH BASINS.

NOTE:

COMPACTED AGGREGATE BASE

CAMBRIDGE-09

CAMBRIDGE-11

CONCRETE CURB AND GUTTER


WITH CAMBRIDGE PAVERS

COMPACTED AGGREGATE BASE

VARIES

GEOTEXTILE AS REQUIRED

GEOTEXTILE AS REQUIRED

CROSSWALK
ON COMPACTED AGGREGATE BASE

DRAWING NO.

GEOTEXTILE 12" (300 MM) WIDE,


TURN UP AGAINST CURB
COMPACTED AGGREGATE BASE

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND

CONCRETE CURB MIN. 8" (200 MM)


WIDE x 16" (400 MM) DEEP

SAW-CUT PAVEMENT
SEAL JOINT

EXISTING ASPHALT PAVEMENT

DRAWING NO.

COMPACTED SOIL SUBGRADE


NOTES:
1. DRAIN MAY BE NECESSARY IN SLOW DRAINING SUBGRADE.
2. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE CONDITIONS. COLDER
CLIMATES AND WEAK SOILS MAY REQUIRE THICKER BASES.
DO NOT COVER ENTIRE TOP OF AGGREGATE BASE WITH GEOTEXTILE.
3.

VARIES
COMPACTED SOIL SUBGRADE
REBAR AS REQUIRED
NOTES:
1. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE CONDITIONS.
2. CONCRETE CURBS DO NOT DEFLECT TO THE SAME DEPTH AS CAMBRIDGE PAVERS OR EXISTING
ASPHALT. THIS DETAIL IS NOT RECOMMENDED FOR OTHER THAN LOW VOLUME
RESIDENTIAL STREETS.
THICKENING ASPHALT PAVEMENT ADJACENT TO CONCRETE CURB IS RECOMMENDED.
3.

VARIES
VARIES

VARIES
VARIES

REBAR

CROSSWALK ON ASPHALT
OR CEMENT TREATED BASE

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
GEOTEXTILE AS REQUIRED
BASE MATERIAL

SECTION AA

UTILITY STRUCTURE
VALVE BOX \ PULL BOX \ LAMPHOLE

EXISTING ASPHALT PAVEMENT


SAW-CUT PAVEMENT
SEAL JOINT
12" (300 MM) WIDE GEOTEXTILE ALONG
PERIMETER TURN UP AT CURB
CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
EXISTING ASPHALT PAVEMENT

EXISTING AGGREGATE BASE

COVER

CAMBRIDGE-15

DRAWING NO.

SUBGRADE
12" (300 MM) WIDE GEOTEXTILE
TURN UP AGAINST COLLAR

COVER
CONCRETE COLLAR MIN. 8" WIDE
x 8" DEEP (200 MM X 200 MM)
ELEVATION TO BE 1/4"
(7 MM) BELOW PAVERS
REBAR

CAMBRIDGE-13

DRAWING NO.

EXISTING SUBGRADE
2" (50 MM) DIA. DRAIN HOLES AT LOWEST
ELEVATIONS, FILL WITH PEA GRAVEL,
COVER WITH GEOTEXTILE
NOTES:
1. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE.
COLDER CLIMATES AND WEAK SOIL MAY REQUIRE THICKER BASES.
BOTTOM ELEVATION OF EXISTING ASPHALT PAVEMENT MUST BE EVEN OR BELOW BEDDING SAND.
CONCRETE BEAMS AT ENDS OF PAVEMENT MAY BE NECESSARY IF ASPHALT IS SUBJECT TO RUTTING.
DO NOT USE DRAIN HOLES TO SUBGRADE WHEN WATER TABLE IS LESS THAN 2' (0.6 M)
FROM TOP OF SUBGRADE. DRAIN TO CATCH BASINS.

2.
3.
4.

VARIES

REBAR

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2" (25-40 MM) BEDDING SAND
BASE MATERIAL

SECTION AA

CONCRETE UTILITY
STRUCTURE

CONCRETE BRICK
AS REQUIRED

GEOTEXTILE
12" (300 MM) WIDE GEOTEXTILE
TURN UP AGAINST COLLAR

UTILITY STRUCTURE

GRATE AND FRAME


CONCRETE COLLAR

1. SIZE AND REINFORCING OF


CONCRETE VARIES WITH TRAFFIC.

SECTION AA

CAMBRIDGE PAVERS
3 1/8" (80 MM)
1" TO 1 1/2"
(25-40
BEDDING SAND
BASE MATERIAL
GEOTEXTILE

NOTE:

CATCH BASIN

COVER

STRING COURSE OF PAVERS


AROUND COLLAR

COVER
CONCRETE COLLAR
MIN. 8" (200 MM) WIDE
ELEVATION TO BE 1/4"
(7MM) BELOW PAVERS

REBAR AS REQUIRED

CAMBRIDGE-14

DRAWING NO.

REBAR
STRING COURSE OF PAVERS
AROUND COLLAR

GRATE AND FRAME


CONCRETE COLLAR
MIN. 8" (200 MM) WIDE
ELEVATION TO BE 1/4" (7MM)
BELOW CAMBRIDGE PAVERS
REBAR
12" (300 MM) WIDE GEOTEXTILE
TURN UP AGAINST COLLAR

COMPACTED SOIL SUBGRADE

CONCRETE CATCH BASIN


PER LOCAL STANDARD

CAMBRIDGE-16

DRAWING NO.

EXISTING CURB
MIN. 2 3/8" (60 MM) THICK
CAMBRIDGE PAVERS
OVER ROOT ZONE
MIN 1/4" (7 MM) WIDE JOINTS
APPROX. 1" TO 1 1/2"
(25-40 MM) BEDDING SAND
GEOTEXTILE
LAVA SLAG WITH
TREE PIT SOIL
MIX 2 TO 1 IN ROOT ZONE

12"
(300
MIN

GEOTEXTILE

B AND B TREE
TREE GRATE
WASHED AGGREGATE
TREE PIT
WITH PLANTING SOIL
MIN. DEPTH 3' (.9 M)
CONCRETE COLLAR

CAMBRIDGE-19

DRAWING NO.

CAMBRIDGE-17

DRAWING NO.

95% COMPACTION OF
SOIL UNDER ROOTBALL
4" (100 MM) DIA. PERFORATED PLASTIC PIPE
WRAPPED WITH WASHED AGGREGATE AND
FILTER FABRIC DRAIN TO STORM SEWER

TREE PIT - NON-COMPACTED


ROOT ZONE UNDER CAMBRIDGE PAVERS

SPRAY NOZZLE
DRAIN WITH HOLES
AT TOP OF CONCRETE BASE
CAMBRIDGE PAVER WITH EMPTY JOINTS
2 3/8" (60 MM) MIN. THICKNESS
ADHESIVE
CONCRETE BASE
FOUNTAIN WALL

DRAIN HOLES AT BOTTOM


OF CAMBRIDGE PAVERS/TOP OF CONCRETE

NOTE: 1. CAMBRIDGE PAVERS CAN BE LAID WITHOUT ADHESIVE.

FOUNTAIN

CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
GEOTEXTILE
COMPACTED SUBGRADE
SEGMENTAL RETAINING WALL
BOND TOP COURSE

COMPACTED OPEN GRADED AGGREGATE


WRAPPED IN GEOTEXTILE
PIPE DRAIN

FOOTER AS REQUIRED
BY WALL DESIGN

RIGID INSULATION WITH


GROOVED BOTTOM FOR DRAINAGE
THICKNESS VARIES WITH
LOCAL CODES AND CLIMATE

CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS
1" (25 MM) THICK BEDDING SAND
GEOTEXTILE
OVERLAP ENTIRE STRIP SEAL
PROTECTION BOARD
GROOVED BOTTOM FOR
DRAINAGE AT BOTTOM

CAMBRIDGE-20

DRAWING NO.

CAMBRIDGE-18

DRAWING NO.

NOTES:
1. MAXIMUM SLOPE SHOULD NOT EXCEED ANGLE OF REPOSE FOR BEDDING SAND.
2. PROVIDE EDGE RESTRAINTS ON SIDES OF INSTALLATION.
3. ENGINEERING OF THE SEGMENTAL RETAINING WALL IS REQUIRED WHEN HEIGHT EXCEEDS
4' (1.0 M).

SLOPE PROTECTION
CAMBRIDGE PAVERS

6
(150
MIN

ROOF DRAIN
GASKET
HOLES FOR DRAINAGE

ROOF DECK OVER HABITABLE SPACE

WATERPROOF MEMBRANE
OVERLAP ENTIRE ALUMINUM PLATE
STRUCTURAL SLAB
SLOPE TO DRAIN
ALUMINUM PLATE
MIN. 1/8" (3 MM) THICK
FASTEN ON ONE SIDE
COMPRESSION SEAL AT CONTROL JOINT
NOTES: 1. CHECK WITH LOCAL WIND CODES FOR BALLAST REQUIREMENTS.
2. PROTECTION BOARD AND INSULATION MUST WITHSTAND STATIC AND DYNAMIC LOADS.

1/2
(13
MIN

12"
(300
MIN

6"
(150
MIN

CAMBRIDGE PAVER
2 3/8" (60 MM) MIN. THICKNESS
1" (25 MM) BEDDING SAND
GEOTEXTILE
OVERLAP ENTIRE PLATE
PROTECTION BOARD
GROOVED BOTTOM FOR
DRAINAGE AT BOTTOM

ROOF DRAIN

ROOF DECK
OVER UNINHABITED SPACE

PARKING GARAGE OVER INHABITED /


UNINHABITED SPACE - DRAIN

DRAWING NO.

CAMBRIDGE-21

CAMBRIDGE-23

DRAWING NO.

CONCRETE ROOF DECK


SLOPE TO DRAIN
WATERPROOF MEMBRANE
NOTES:
1. PROTECTION BOARD AND INSULATION MUST WITHSTAND STATIC AND DYNAMIC VEHICULAR LOADS.
2. INSULATION MAY BE EXCLUDED FOR SOME APPLICATIONS OVER INHABITED SPACE.

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
GEOTEXTILE
TURN UP AT DRAIN AND
ALL VERTICAL SURFACES
PROTECTION BOARD 1/4" (7 MM) MIN.
AS REQUIRED
RIGID INSULATION
THICKNESS VARIES WITH
LOCAL CODES AND CLIMATE
ROOF DRAIN
HOLES FOR DRAINAGE

GASKET
HOLES FOR DRAINAGE
WATERPROOF MEMBRANE
OVERLAP ENTIRE PLATE
STRUCTURAL SLAB
SLOPE TO DRAIN
ALUMINUM PLATE
MIN. 1/8" (3 MM) THICK
FASTEN ON ONE SIDE
COMPRESSION SEAL AT CONTROL JOINT
NOTES: 1. CHECK WITH LOCAL WIND CODES FOR BALLAST REQUIREMENTS.
2. PROTECTION BOARD MUST WITHSTAND STATIC AND DYNAMIC LOADS.

1/2
(13
MIN

CAMBRIDGE PAVERS
3 1/8" (80 MM) MIN THICKNESS

GEOTEXTILE

APPROX. 1" TO 1 1/2"


(25-40 MM) BEDDING SAND

PROTECTION BOARD 1/4" (7 MM) MIN


AS REQUIRED
WATERPROOF MEMBRANE

WATERPROOF ADHESIVE

CAMBRIDGE-22

DRAWING NO.

STRIP SEAL AT CONSTRUCTION JOINT

EPOXY GROUT FILLER

PARKING GARAGE OVER UNINHABITED


SPACE - EXPANSION JOINT

CAMBRIDGE PAVERS
3 1/8" (80 MM) MIN. THICKNESS

GEOTEXTILE

1" TO 1 1/2"
(25-40 MM) BEDDING SAND

PROTECTION BOARD 1/4" (7 MM) MIN.


AS REQUIRED

RIGID INSULATION
WATERPROOF ADHESIVE

CAMBRIDGE-24

DRAWING NO.

STRIP SEAL AT CONSTRUCTION JOINT

EPOXY GROUT FILLER

WATERPROOF MEMBRANE

STRUCTURAL SLAB
SLOPE TO DRAIN

PARKING GARAGE OVER INHABITED


SPACE - EXPANSION JOINT

NOTE:

NOTE:

1. BASE, SUB-BASE, AND SUBGRADE THICKNESS VARY WITH


LOADS, SUBGRADE STRENGTH, AND CLIMATE.

3.

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS

APPROX. 1" TO 1 1/2"


(25-40 MM) BEDDING SAND

CEMENT TREATED BASE

COMPACTED SOIL SUBGRADE

CAMBRIDGE-26

DRAWING NO.

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS

1" TO 1 1/2"
(25-40 MM) BEDDING SAND

GEOTEXTILE
TURN UP AT SIDES/EDGES

EXISTING ASPHALT
OR CONCRETE PAVEMENT

EXISTING SUB-BASE

EXISTING SOIL SUBGRADE

PORT / INDUSTRIAL PAVEMENT


ON EXISTING ASPHALT OR CONCRETE

CAMBRIDGE-28

DRAWING NO.

NOTES:
1. EXISTING ASPHALT OR CONCRETE PAVEMENT SHALL BE THOROUGHLY INSPECTED FOR AREAS
IN NEED OF PATCHING OR REPLACEMENT. CONDUCT ALL REPAIRS AND FILL ALL CRACKS
GREATER THAN 1/4" (7 MM) WIDE PRIOR TO PLACING GEOTEXTILE, SAND, AND CAMBRIDGE PAVERS.
PROVIDE DRAINAGE OF SAND LAYER THROUGH PEA GRAVEL-FILLED WEEP HOLE(S) OR
CATCH BASIN(S).
2.

GAS STATION
ON CEMENT TREATED BASE

NOTES:
1. BASE, SUB-BASE, AND SUBGRADE THICKNESS VARY WITH
LOADS, SUBGRADE STRENGTH, AND CLIMATE.
CAMBRIDGE PAVERS MAY BE INLAID ON EXISTING ASPHALT
OR CONCRETE GAS STATION PAVEMENTS.
SEALING JOINTS OF PAVERS IS RECOMMENDED.
2.

VARIES

CAMBRIDGE PAVERS
3 1/8" (60 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND

EPOXY GROUT FILLER

WOVEN GEOTEXTILE

SEAL AT JOINT

STRUCTURAL SLAB
SLOPE TO DRAIN
ON STEEL OR CONCRETE BEAMS

DRAWING NO.

CAMBRIDGE-25

CAMBRIDGE PAVER
3 1/8" (80 MM) MIN. THICKNESS
1" TO 1 1/2"
(25-40 MM) BEDDING SAND
GEOTEXTILE
TURN UP AT SIDES/EDGES

CEMENT TREATED BASE

COMPACTED AGGREGATE
SUB-BASE AS REQUIRED

CAMBRIDGE-27

DRAWING NO.

COMPACTED OR STABILIZED
SUBGRADE

PORT / INDUSTRIAL / AIRFIELD


PAVEMENT W/CEMENT TREATED BASE

VARIES

1. PROVIDE DRAINAGE OF EXCESS MOISTURE IN BEDDING SAND


AT PERIMETER OF STRUCTURAL SLAB.

BRIDGE DECK

VARIES
VARIES

VARIES

1" TO 1 1/2"
(25-40 MM) BEDDING SAND

CAMBRIDGE PAVER (FAA,P502)


3 1/8" (80 MM) MIN. THICKNESS
WITH SEALER

GEOTEXTILE
TURN UP AT SIDES
TO COVER CAMBRIDGE PAVERS

APPROX. 1" TO 1 1/2"


(25-40 MM) BEDDING SAND

CAMBRIDGE PAVERS (P-502)


3 1/8" (80 MM) MIN. THICKNESS

VARIES
VEGETATION
CAMBRIDGE TURFSTONE
3 1/8" (80 MM) MIN. THICKNESS
MAX. SLOPE 1 TO 1
TOPSOIL IN OPENINGS
FILL 1/2" (13 MM) BELOW SURFACE

SLOPE PROTECTION
CAMBRIDGE TURFSTONE

COMPACTED EMBANKMENT SOIL

CAMBRIDGE-30

CAMBRIDGE-32

DRAWING NO.

STAKE EVERY THIRD ROW OF GRIDS


WITH 12" x 3/8" DIA. (300 MM x 10 MM)
STEEL PINS

AIRFIELD PAVEMENT
ON EXISTING ASPHALT OR CONCRETE

NOTE:
1. EXISTING ASPHALT OR CONCRETE PAVEMENT SHALL BE THOROUGHLY INSPECTED FOR AREAS
IN NEED OF PATCHING OR REPLACEMENT. CONDUCT ALL REPAIRS AND FILL ALL CRACKS
GREATER THAN 1/4" (7 MM) WIDE PRIOR TO PLACING GEOTEXTILE, SAND, AND CAMBRIDGE PAVERS.

EXISTING SUBGRADE

EXISTING BASE AND SUB-BASE

EXISTING ASPHALT
OR CONCRETE PAVEMENT

GEOTEXTILE
TURN UP AT SIDES
TO COVER CAMBRIDGE PAVERS

CEMENT TREATED BASE (P-304)


OR ASPHALT BASE (P-401)

COMPACTED AGGREGATE
SUB-BASE AS REQUIRED
(P-209 OR P-154, AS REQUIRED)
COMPACTED OR STABILIZED
SOIL SUBGRADE (P-152)

CAMBRIDGE-29

COMPACTED SOIL AT PERIMETER


CAMBRIDGE TURFSTONE
3 1/8" (80 MM) MIN. THICKNESS
SOD PLUGS OR GRASS SEED
TOPSOIL IN OPENINGS
FILL 1/2" (13 MM) BELOW SURFACE
1" TO 1 1/2"
(25-40 MM) BEDDING SAND

CAMBRIDGE-31

DRAWING NO.

COMPACTED AGGREGATE BASE

GEOTEXTILE AS REQUIRED
TURN UP AT SIDES

COMPACTED SUBGRADE

CAMBRIDGE TURFSTONE-FIRELANE,
DRIVEWAY & INTERMITTENT PARKING

NOTES: 1. BASE THICKNESS VARIES WITH TRAFFIC, CLIMATE, AND SUBGRADE.


2. MINIMUM BASE THICKNESS: 6" (150 MM) RESIDENTIAL DRIVEWAYS,
8" FIRELANES & PARKING LOTS.

6"
(150
MIN

AIRFIELD PAVEMENT WITH


CEMENT TREATED OR ASPHALT BASE

NOTE:
1. BASE, SUB-BASE, AND SUBGRADE THICKNESS VARY WITH
LOADS, SOIL STRENGTH, AND CLIMATE.

VARIES

12" (300 MM)


MIN.

12" (300 MM)


MIN.

RIP-RAP OR CONCRETE TOE AND SIDES

GEOTEXTILE
WRAP AROUND TOE ON ALL SIDES

FILL OPENINGS ABOVE MEAN WATER LEVEL


WITH TOPSOIL AND VEGETATION
CAMBRIDGE TURFSTONE
3 1/8" (80 MM) MIN. THICKNESS
MAX. SLOPE 1 TO 1
EXTEND MIN. TWO (2) COURSES
ABOVE MEAN WATER LEVEL
RIPARIAN VEGETATION
MEAN WATER LEVEL

24" (600 MM) MIN.

RIPARIAN STABILIZATION

COMPACTED
SUBGRADE

DRAWING NO.

CAMBRIDGE-33

CAMBRIDGE-35

DRAWING NO.

RIP-RAP OR CONCRETE TOE AND SIDES

GEOTEXTILE
WRAP AROUND TOE ON ALL SIDES

COMPACTED SUBGRADE

GEOTEXTILE ON SOIL SUBGRADE


AS REQUIRED

CAMBRIDGE TURFSTONE FOR STREAM BANKS AND LAKESIDES

GRAVEL OR PAVED APPROACH RAMP


CAMBRIDGE TURFSTONE
3 1/8" (80 MM) MIN. THICKNESS
MAX SLOPE = 12
AGGREGATE IN OPENINGS
GRAVEL COMPACTED TO
8" (200 MM) MIN. DEPTH

24" (600 MM) MIN.

BOAT RAMP
CAMBRIDGE TURFSTONE

CAMBRIDGE TURFSTONE
3 1/8" (80 MM) MIN THICKNESS
MAX SLOPE 1 TO 1

VEGETATION

TOPSOIL IN OPENINGS
FILL 1/2" (13 MM)
BELOW SURFACE

COMPACTED SOIL SUBGRADE

NOTE: 1. AGGREGATE MAY BE USED IN OPENINGS OF GRID PAVERS.

DITCH LINER FOR INTERMITTENT


FLOWS - CAMBRIDGE TURFSTONE

NOTE: ALL CROSS-SECTION DRAWINGS SHOWN


ARE AVAILABLE ON CD-ROM.

CAMBRIDGE-34

DRAWING NO.

www.cambridgepavers.com

You might also like