You are on page 1of 64

Power and Gas

We power the world with innovative gas turbines

siemens.com/ gasturbinesII

Gas turbines from


4 to 400 MW
The Siemens gas turbine range has been designed and
tailored to help meet our customers challenges in a
dynamic market environment.
Our models range from 4 to 400MW, fulfilling the
requirements of a wide spectrum of applications in terms
of efficiency, reliability, flexibility, and environmental
compatibility.
The products offer low lifecycle costs and an excellent
return on investment.

Industrial and aeroderivative


gas turbines

Heavy-duty
gas turbines

SGT5-8000H

50 Hz

400 MW

SGT5-4000F

307 MW

SGT5-2000E

187 MW
296 MW

SGT6-8000H

60 Hz

SGT6-5000F

242 MW
116 MW

SGT6-2000E
Ind. Trent 60

53 to 66 / 54 to 62 MW
48 to 53 MW

SGT-800
SGT-750

38 / 39 MW

SGT-700

33 / 34 MW

50 Hz

Ind. RB211

27 to 32 / 28 to 34 MW

or

SGT-600

60 Hz

SGT-500
SGT-400
SGT-300

24 / 25 MW
19 / 19 MW
13 to 14 / 13 to 15 MW
8 / 8 MW

SGT-200

7 / 8 MW

SGT-100

5 / 6 MW

Ind. 501

4 to 6 MW

Siemens gas turbines overview


[Power generation in MW(e) / Mechanical drive in MW]

SGT-500
SGT-600
Industrial 501
Heavy-duty
gas turbines

Industrial
gas turbines

Industrial RB211

[4 to 6 MW]

SGT-100

[5/6 MW]

SGT-700

SGT-200

[7/8 MW]

SGT-750

SGT-300

[8/8 MW]

SGT-800

SGT-400

[13 to 14 /13 to 15 MW]

50 Hz

Industrial Trent 60
and

60 Hz

Aeroderivative
gas turbines

Gas turbines in the range of

Gas turbines in the range of

015 MW

1699 MW

SGT6-2000E

[116 MW]

[19/19 MW]

SGT6-5000F

[242 MW]

[24/25 MW]

SGT6-8000H

[296 MW]

[33 / 34 MW]

SGT5-2000E

[187 MW]

[38 / 39 MW]

SGT5-4000F

[307 MW]

[48 to 53 MW]

SGT5-8000H

[400 MW]

60 Hz

[27 to 32/ 28 to 34 MW]

50 Hz

[53 to 66/ 54 to 62 MW]

Gas turbines in the range of

100400 MW

General note:
All simple cycle and mechanical drive performance data in
this document are gross values at ISO ambient conditions.
All combined cycle performance data in this document are
net values at ISO ambient conditions, assuming 50mbar
condenser pressure.

Table of
contents
Siemens gas turbines are suitable for a wide range
of applications:
Power generation application for utilities, independent
power producers, oil and gas, and industrial users,
such as chemicals, pulp and paper, food and beverage,
sugar, automotive, metalworking, mining, cement,
wood processing, and textiles.
Mechanical drive applications for oil and gas, and
chemical industry.

Heavy-duty gas turbines.................................................................6


Industrial gas turbines..................................................................28
Aeroderivative gas turbines...........................................................48
References...................................................................................56
Performance data overview..........................................................58

Heavy-duty
gas turbines
Siemens heavy-duty gas turbines are robust and
flexible engines, designed for large simple or
combined cycle power plants. They are suitable
for peak, i ntermediate, or base load duty, as well
as for cogeneration applications.
Customers benefit from our extensive validation
and testing capabilites.
Our engines are proven in commercial operation
and provide outstanding efficiency.

SGT5-8000H...................................................................................8
SGT6-8000H.................................................................................10
SGT5-4000F..................................................................................14
SGT6-5000F.................................................................................18
SGT5-2000E.................................................................................22
SGT6-2000E.................................................................................24

SGT5-8000H
Heavy-duty gas turbine
The SGT5-8000H offers outstanding performance and high
flexibility. With a gross power output of 400 MW, it is the
worlds most powerful gas turbine in commercial operation
today.

The turbine is the core component of highly efficient


gas-fired power plants, designed for 600 MW in combined
cycle operation, and combined cycle efficiencies of more
than 60%.
With more than 180,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
availability.

References
Dsseldorf Lausward,
Germany
Turnkey combined cycle power plant
Power output: 595 MW(e) and up
to 300 MW(th)
Customer: Stadtwerke Dsseldorf AG
Scope: SCC5-8000H 1S with
1 x SGT5-8000H gas turbine
package

Bandirma II, Cengiz, Turkey


Combined cycle power plant
Power output: 583 MW
Customer: Cengiz Enerji Samsun
Scope: SCC5-8000H with
1 x SGT5-8000H gas turbine
package for power island installation

Dsseldorf Lausward, Germany


8

Power output: 400 MW


Outstanding performance
High flexibility, short start-up times
Proven in commercial operations

The SGT5-8000H achieves a world-class efficiency of more than 60% in combined cycle operations

High operational flexibility due to world


class fast cold start and hot restart capability

Simple cycle power generation

Combined cycle power generation

Power output

400 MW

21

Natural gas, LNG, distillate oil, Arabian Super


Light crude oil, kerosene, condensate; other
fuels on request

Siemens combined
cycle power plant

11

Fuel

Net plant power output

600 MW

1,200 MW

Net plant efficiency

>60%

>60%

Net heat rate

<6,000 kJ/kWh
(<5,687 Btu/kWh)

<6,000 kJ/kWh
(<5,687 Btu/kWh)

Frequency

50 Hz

Gross efficiency

40.0%

Heat rate

8,999 kJ/kWh (8,530 Btu/kWh)

Number of gas turbines

Turbine speed

3,000 rpm

Pressure/reheat

Triple/Yes

Triple/Yes

Pressure ratio

19.2:1

Exhaust mass flow

869 kg/s (1,915 lb/s)

Physical dimensions

Exhaust temperature

627C (1,161F)

Approx. weight

445,000 kg (981,000 lb)

NOx emissions

<25 ppmvd at 15% O2 on fuel gas


(without water injection for NOX control),
<42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control)

Length

12.6 m (41 ft)

Width

5.5 m (18 ft)

Height

5.5 m (18 ft)

SGT6-8000H
Heavy-duty gas turbine
The SGT6-8000H offers outstanding performance and high
flexibility. The air-cooled turbine with a gross power output
of 296 MW is designed for simple and fast combined cycle
integration and short start-up times.
The turbine is the core component of highly efficient
gas-fired power plants, designed for 440 MW in combined

References
Riviera Beach, Florida, USA
Supply of gas turbine packages
Power output: 3274 MW
Customer: Florida Power & Light
Scope: 3SGT6-8000H gas
turbine packages

Andong, South Korea


Power block for combined cycle
power plant
Power output: 416 MW
Customer: Korea Southern
Power Co. Ltd.
Scope: SCC6-8000H 1S with
1 x SGT6-8000H gas turbine

Dangjin 3, South Korea


10

cycle operation with combined cycle efficiencies of more


than 60%.
With more than 180,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
availability.

Power output: 296 MW


Outstanding performance
High flexibility, short start-up times
Proven in commercial operations

The blade design provides high efficiency and


is designed to ensure high reliability with low
outage risk

Valves allow for controlled cooling air supply,


to cover the needs of different o
perating
conditions

The SGT6-8000H can be easily integrated in


single-shaft or multi-shaft combined cycle
plants

Simple cycle power generation

Combined cycle power generation

Power output

296 MW

Fuel

Natural gas, LNG, distillate oil, Arabian Super


Light crude oil, kerosene, condensate; other
fuels on request

Siemens
combined
cycle power
plant

Frequency

60 Hz

Gross efficiency

40%

Heat rate

11

21

31

Net plant
power output

440 MW

880 MW

1,320 MW

Net plant
efficiency

>60%

>60%

>60%

8,999 kJ/kWh (8,530 Btu/kWh)

Turbine speed

3,600 rpm

Net heat rate

<6,000 kJ/kWh
(<5,687 Btu/kWh)

<6,000 kJ/kWh
(<5,687 Btu/kWh)

<6,000 kJ/kWh
(<5,687 Btu/kWh)

Pressure ratio

19.5:1

Exhaust mass flow

640 kg/s (1,410 lb/s)

Number of
gas turbines

Exhaust temperature

630C (1,166F)

Triple/Yes

Triple/Yes

Triple/Yes

NOx emissions

<25 ppmvd at 15% O2 on fuel gas


(without water injection for NOX control),
<42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control)

Pressure/
reheat

Physical dimensions
Approx. weight

289,000 kg (637,000 lb)

Length

10.5 m (34 ft)

Width

4.3 m (14 ft)

Height

4.3 m (14 ft)

11

Turbine
High cycling capability due to
fully internally air cooled
turbine section

SGT-8000H series: Key features

3D four stage turbine with


advanced materials and thermal
barrier coating

Rotor

Shorter outages:
All turbine vanes and blades
replaceable without rotor lift;
vane 1, blade 1 and 4replaceable
without cover lift

Proven rotor design (Hirth serration,


central tie rod, internal cooling
air passages): For world class fast
(cold) start and hot restart
capability

Easy rotor destacking on-site: Disc


assembly with Hirth serration and
central tie rod

1
Compressor
Four stages of fast acting variablepitch guide vanes (VGV) allowing
for improved part load efficiency
and high load transients

2
3

Evolutionary 3D blading
Rotating blades replaceable without
rotor destack or lift

Combustion
Advanced can annular
combustion system

Bearings

More than 60% combined cycle


efficiency

Hydraulic Clearance Optimization


(HCO) for reduced clearance losses
Transient protection of clearances
for reduced degradation with
HCO active clearance control

Flexibility

Performance

Serviceability

SGT5-4000F
Heavy-duty gas turbine
The proven SGT5-4000F gas turbine has a robust design
with internal cooling air passages for trusted long-term
operation and fast start-up capability. The advanced annular
combustion chamber with individually replaceable heat
shields allows for easy and fast walk-in maintenance.
Hydraulic Clearance Optimization (HCO) reduces clearance
losses to increase the gas turbine efficiency and minimize
degradation at start-up and shut down.

References
Kirishi, Russia
Supply of gas turbine packages
Power output: 800 MW
Customer: OGK-2 JSC, a subsidiary of
Gazprom Energo Holding OOO/LLC
Scope: Repowering project with
2SGT5-4000F gas turbine packages

Shuweihat S2, Abu Dhabi


Turnkey combined cycle power plant
Power output: 1,500 MW
Customer: Suez Energy Middle East
Scope: 2SCC5-4000F 21 with
4SGT5-4000F gas turbine packages

Al Taweelah, United Arab Emirates


14

Today, around 340 turbines have been sold. The installed


fleet has accumulated an impressive fleet experience of
11.5 million equivalent operating hours, and a fleet
reliability of 99.2%.

Power output: 307 MW


Proven design, large fleet
experience
Easy maintenance, high availability
High operational flexibility

The SGT5-4000F is a well-proven 50 Hz gas turbine


with an outstanding reliability and availability

Easy plant integration: Proven package


concepts for early power generation in simple
cycle operation; fast project execution

For combined cycle applications, the


SGT5-4000F is offered in single-shaft or
multi-shaft (21) arrangements

Simple cycle power generation

Combined cycle power generation

Power output

307 MW

21

Natural gas, LNG, ethane, propane, distillate oil


(dual fuel option); other fuels on request

Siemens combined
cycle power plant

1S

Fuel

Net plant power output

445 MW

890 MW

50 Hz

Net plant efficiency

58.7%

58.7%

Gross efficiency

40.0%

Net heat rate

Heat rate

9,001 kJ/kWh (8,532 Btu/kWh)

6,133 kJ/kWh
(5,812 Btu/kWh)

6,133 kJ/kWh
(5,812 Btu/kWh)

Turbine speed

3,000 rpm

Number of gas
turbines

Pressure ratio

18.8:1

Pressure/reheat

Triple/Yes

Triple/Yes

Exhaust mass flow

723 kg/s (1,595 lb/s)

Frequency

Exhaust temperature

579C (1,074F)

NOx emissions

<25 ppmvd at 15% O2 on fuel gas


(without water injection for NOX control),
<42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control),
<58 ppmvd at 15% O2 on fuel oil
(without water injection for NOX control)

Physical dimensions
Approx. weight

312,000 kg (688,000 lb)

Length

10.8 m (35 ft)

Width

5.2 m (17 ft)

Height

4.8 m (16 ft)

15

Combustion System
Low NOx burners, for dry operation
with gaseous & liquid fuels

SGT5-4000F: Key features

Homogeneous outlet profile for


minimized mechanical and
thermal turbine stress

Rotor

Robust design with internal


cooling air passages for trusted
long term operation and fast
start-up capability
Easy de-stacking on-site due to
Hirth serration and central tie
rod

HCO
Improved performance

and minimized d
egradation by
active control of clearances at
start-up and shut down

Annular chamber with individually


replaceable heat shields for easy
and fast walk-in maintenance

Turbine
High cycling capability due to
fully air cooled hot gas path
without cooling air coolers

Compressor
Proven design

Four stages with film cooling


and thermal barrier coatings for
well balanced turbine load and
low lifecycle costs

Rotating blades of all 15 stages


replaceable without rotor lift

Flexibility

Performance

Serviceability

SGT6-5000F
Heavy-duty gas turbine
The SGT6-5000F gas turbine offers economical power
generation with fast start-up for peak, intermediate, or
base load duty. It achieves peak values for reliability and
continuous operation with highest performance values
in its class.

References
Ras Al-Khair, Saudi Arabia
Supply of gas turbine packages
Power output: 2,400 MW
Customer: Consortium comprising
AlArrab Contracting Company,
Saudi Arabia and the Chinese SepcoII Electric Power Construction
Corporation
Scope: 12SGT6-5000F gas turbine
packages

Marsh Landing, USA


Power block for open cycle power
plant
Power output: 720 MW
Customer: NRG Energy
Scope: SCC6-5000F with 4
SGT6-5000F gas turbine packages
La Caridad, Sonora, Mexico
18

Today, around 370 turbines have been sold. The installed


fleet has accumulated more than 11 million equivalent
operating hours, with a fleet reliability of 99.2%.

Power output: 242 MW


Highest power output for 60 Hz
F-class
Fast start-up and load changing
capabilities
Low emissions with NOx emissions of
<9 ppm on gas and <25 ppm on oil
The SGT6-5000F offers world class reliability and best in class emission values

The SGT6-5000F is the first choice for reliable simple


or combined cycle operation in the 60 Hz market

Simple cycle power generation

Combined cycle power generation

Power output

242 MW

11

21

Fuel

Natural gas, LNG, syngas, ethane, propane,


condensate, distillate oil, Arabian Super Light
crude oil, Arabian Extra Light crude oil, biodiesel, alcohols, Jet-A oil, kerosene

Siemens combined
cycle power plant
Net plant power output

360 MW

725 MW

Frequency

60 Hz

Gross efficiency

39.0%

Heat rate

9,230 kJ/kWh (8,748 Btu/kWh)

Turbine speed

3,600 rpm

Pressure ratio

18.9:1

Exhaust mass flow

576 kg/s (1,270 lb/s)

Exhaust temperature

600C (1,113F)

NOx emissions

<9 ppmvd at 15% O2 on fuel gas


(without water injection for NOx control),
<25 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control)

Net plant efficiency

58.1%

58.6%

Net heat rate

6,193 kJ/kWh
(5,870 Btu/kWh)

6,138 kJ/kWh
(5,817 Btu/kWh)

Number of gas turbines

Pressure/reheat

Triple/Yes

Triple/Yes

Physical dimensions
Approx. weight

219,000 kg (482,000 lb)

Length

10.1 m (33 ft)

Width

4.0 m (13 ft)

Height

4.6 m (15 ft)

Combined cycle plant turn down in emissions compliance to 20% load.

Gas turbine turn down in emissions compliance


to 30% load. Fast start-up capable of generating
200 MW in 10 minutes from turning gear speed.
Gas turbine ramp rate up to 40 MW/min.

19

Turbine
Four stage turbine with
proven conventionally cast
turbine alloys

SGT6-5000F: Key features

Low firing temperature for


long service intervals

Combustion
Fuel flexible and proven Ultra
Low NOx combustion system
Single digit emissions down to
30%load

4
3
2

Rotor
Compressor
Variable guide vanes for part
load efficiency and transient
operation

Single tie rod with Hirth


serrations for reliable torque
transmission
External rotor air cooler for
constant cooling air temperature
across the ambient range

Blades and vanes removable


without a rotor de-stack or lift

Flexibility

Performance

Serviceability

SGT5-2000E
Heavy-duty gas turbine
The SGT5-2000E gas turbine is a proven, robust engine for
the 50 Hz market which is used in simple cycle or combined
cycle processes with or without combined heat and power.
It is suitable for all load ranges, including peak load.
The SGT5-2000E offers outstanding fuel flexibility. It can be
fired with low calorific gases or gases containing CO2, H2S
and N2, as well as with crude oil and other liquid fuels with

References
Braemar 2, Australia
Power block for open cycle power
plant
Power output: 450 MW
Customer: ERM Power
Scope: 3SGT5-2000E gas turbine
packages

Geregu 2, Nigeria
Turnkey open cycle power plant
Power output: 434 MW
Customer: Niger Delta Power
Holding Company
Scope: 3SGT5-2000E gas turbine
packages

Az-Zour, Kuwait
22

high viscosity. It provides low NOx emissions, even in the


part load range.
Today, around 480 turbines have been sold (approx. 220
under license). Our installed fleet has accumulated more
than 17 million equivalent operating hours. The SGT-2000E
series fleets overall best-in-class r eliability exceeds 99%.

Power output: 187 MW


Best-in-class reliability
High operational and fuel flexibility
Easy maintenance

Best-in-class reliable technology; robust and flexible performance

Service-friendly design and customer-focused maintenance intervals


help to keep life cycle costs down

Simple cycle power generation

Combined cycle power generation

Power output

187 MW

11

21

Fuel

Natural gas, LNG, syngas, blast furnace gas,


biogas, ethane, propane, condensate, distillate
oil, heavy and crude oils, bio-diesel, alcohols,
naphtha, kerosene

Siemens combined
cycle power plant
Net plant power output

275 MW

551 MW

Net plant efficiency

53.3%

53.3%

Net heat rate

6,755 kJ/kWh
(6,403 Btu/kWh)

6,755 kJ/kWh
(6,403 Btu/kWh)

Number of gas turbines

Pressure/reheat

Dual/No

Dual/No

Frequency

50 Hz

Gross efficiency

36.2%

Heat rate

9,945 kJ/kWh (9,427 Btu/kWh)

Turbine speed

3,000 rpm

Pressure ratio

12.1:1

Exhaust mass flow

558 kg/s (1,230 lb/s)

Physical dimensions

Exhaust temperature

536 C (997F)

Approx. weight

189,000 kg (417,000 lb)

<25 ppmvd at 15% O2 on fuel gas


(without water injection for NOx control),
<42 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control)

Length

10.3 m (34 ft)

Width

4.0 m (13 ft)

Height

4.0 m (13 ft)

NOX emissions

23

SGT6-2000E
Heavy-duty gas turbine
The SGT6-2000E gas turbine is a proven, robust engine for
the 60 Hz market which is used in simple cycle or combined
cycle processes with or without combined heat and power
supply. It is suitable for all load ranges, including peak load.
The SGT6-2000E offers outstanding fuel flexibility.
It can be fired with low calorific gases or gases containing
CO2, H2S and N2, as well as with crude oil and other liquid

References
Hsinta, Taiwan
Combined cycle power plant
Power output: 2,200 MW
Customer: Taiwan Power Company
Scope: 5SCC6-2000E 31 with
15SGT6-2000E gas turbine
packages

Shoaiba, Saudi Arabia


Most powerful and efficient crude
oil plant in the world
Power output: 1,200 MW
Customer: Saudi Electricity Company
Scope: 2SCC6-2000E 51 with
10SGT6-2000E gas turbine
packages

Charles D. Lamb Energy Center, Oklahoma, USA


24

fuels with high viscosity. It provides low NOx emissions,


even in the part load range.
Today, around 110 turbines have been sold, resulting in
a fleet experience of nearly 7 million equivalent operating
hours. The SGT-2000E series fleets overall best-in-class
reliability constantly exceeds 99%.

Power output: 116 MW


Best-in-class reliability
High operational and fuel flexibility
Easy maintenance

Two accessible silo combustion chambers for easy


maintenance; ceramic tiles can be replaced individually

Variable inlet guide vanes (IGV); all


rotating blades replaceable without rotor
de-stack or lift

Excellent start-up and part load behavior,


at 30 MW/min ramp rate

Simple cycle power generation

Combined cycle power generation

Power output

116 MW

11

21

Fuel

Natural gas, LNG, syngas, blast furnace gas,


biogas, ethane, propane, condensate, distillate
oil, heavy and crude oils, bio-diesel, alcohols,
naphtha, kerosene

Siemens combined
cycle power plant
Net plant power output

171 MW

342 MW

Net plant efficiency

51.3%

52.0%

Net heat rate

7,018 kJ/kWh
(6,651 Btu/kWh)

6,923 kJ/kWh
(6,561 Btu/kWh)

Number of gas turbines

Pressure/reheat

Dual/No

Dual/No

Frequency

60 Hz

Gross efficiency

34.3%

Heat rate

10,496 kJ/kWh (9,949 Btu/kWh)

Turbine speed

3,600 rpm

Pressure ratio

12.1:1

Exhaust mass flow

367 kg/s (809 lb/s)

Physical dimensions

Exhaust temperature

537C (999F)

Approx. weight

108,000 kg (239,000 lb)

<25 ppmvd at 15% O2 on fuel gas


(without water injection for NOx control),
<42 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control)

Length

9.1 m (30 ft)

Width

3.3 m (11 ft)

Height

3.3 m (11 ft )

NOx emissions

25

Compressor

SGT-2000E series: Key features

Emission-compliant operation down to


45% at constant exhaust temperature
Fast-acting variable inlet guide vanes
for grid frequency stabilization
All rotating blades replaceable without
rotor de-stack/lift

Combustion
Full fuel flexibility, ranging from heavy
fuel oil to low calorific gases

1
Axial Exhaust

Two easily accessible silo combustion


chambers for fast maintenance
Lining with ceramic tiles which can be
replaced individually

Cold end generator drive for


optimal flow pattern

5
Rotor and Bearings
Transient protection of clearances for
reduced degradation with Hydraulic
Clearance Optimization (HCO) active
clearance control

Light-weight, highly rigid design with


excellent start-up performance
Built disc-type rotor with radial Hirth
serrations and one central tie rod,
rotor de-stacking on-site

Turbine
Four stage turbine, blades and vanes
with Si3D design for enhanced
performance

Flexibility

Performance

Serviceability

27

Industrial
gas turbines
The industrial gas turbine models with their compact
and rugged design make them an ideal choice for
both i ndustrial power generation and mechanical
drive applications.
Their high steam-raising capabilities help achieve
overall plant efficiency of 80percent or higher.
They are proven with more than 2,250 units sold at
small utilities, independent power producers, and in
the oil and gas industry.

SGT-800...........................................................................................30
SGT-750...........................................................................................32
SGT-700...........................................................................................34
SGT-600...........................................................................................36
SGT-500...........................................................................................38
SGT-400...........................................................................................40
SGT-300...........................................................................................42
SGT-200...........................................................................................44
SGT-100...........................................................................................46

SGT-800
Industrial gas turbine
The SGT-800 industrial gas turbine offers broad flexibility
in fuels, operating conditions, maintenance concepts,
package solutions, and ratings.
The excellent efficiency and steam-raising capability
make it outstanding in cogeneration and combined cycle
installations. The SGT-800-based power plant, designed
for flexible operation, is perfectly suited as grid support.

References
Amata Nakorn, Thailand
Combined cycle cogeneration
power plants
Customer: Amata B. Grimm
Power Limited (ABP)
Scope: 12SGT-800 gas turbines
and 9SST-400 steam turbines

Hassi Rmel, Algeria


Combined cycle power plant
Customer: Abengoa
Scope: 2SGT-800 gas turbines
and 1SST-600 steam turbine

Two SGT-800 packages at Amata Nakorn, Chonburi, Thailand


30

The SGT-800 combines a simple, robust design, for high


reliability and easy maintenance, with high efficiency
and low emissions. With a proven, long-term record of
successful installations around the world, the SGT-800 is
an excellent choice for power generation for industrial
and oil and gas applications.

Power generation:
47.5/50.5/53.0 MW(e)
Proven reliability
Flexible solution
Excellent performance

SGT-800 core engine is available in three ratings with


standard options for hot and cold climates

Classic package easily transported and


installed at site, easy on-site maintenance

Single lift package short installation and commissioning time at site; U.S. adapted version

Physical dimensions
Simple cycle power generation
47.5 MW version

50.5 MW version

53.0 MW version

Classic package

Single lift package

290,000 kg
(617,300 lb)

320,000 kg
(705,500 lb)

Power output

47.5 MW(e)

50.5 MW(e)

53.0 MW(e)

Approx.
weight

Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Length

27.9 m (91 ft)

19.6 m (64 ft)

Gross efficiency

37.7%

38.3%

39.0%

Width

7.3 m (24 ft)

4.7 m (15 ft)

Heat rate

9,547 kJ/kWh

9,389 kJ/kWh

9,231 kJ/kWh

Height

15.1 m (49 ft)

15.3 m (50 ft)

Turbine speed

6,608 rpm

6,608 rpm

6,608 rpm

Pressure ratio

20.1:1

21.0:1

21.4:1

Exhaust gas flow

132.8 kg/s

134.2 kg/s

137.2 kg/s

Exhaust gas temperature

541C (1,007F)

553C (1,027F)

551C (1,024F)

NOx emissions

15 ppmvd at 15% O2 on fuel gas (with DLE)


11 Combined cycle power plant

Net plant output

66.6 MW(e)

71.4 MW(e)

74.0 MW(e)

Net plant efficiency

53.8%

55.1%

55.6%

Net plant heat rate

6,693 kJ/kWh

6,530 kJ/kWh

6,475 kJ/kWh

Number of gas turbines

21 Combined cycle power plant


Net plant output

135.4 MW(e)

143.6 MW(e)

150.0 MW(e)

Net plant efficiency

54.7%

55.4%

56.2%

Net plant heat rate

6,583 kJ/kWh

6,494 kJ/kWh

6,406 kJ/kWh

Number of gas turbines

Note: Standard design; ISO ambient conditions. No intake or exhaust loss.


Fuel: Natural gas. Options available for other gases within specification
and dual fuel with gas and Diesel no2.
The combined cycle plant SCC-800 is also available based on more than
two SGT-800. All combined cycle performance is based on 2 pressure,
no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

31

SGT-750
Industrial gas turbine
With maximized uptime, top-class performance, and a low
environmental footprint offering the customer high lifetime
profitability, the SGT-750 industrial gas turbine is a perfect
choice for the oil and gas industry as well as industrial
power generation.
The modular and flexible engine enables onshore or offshore
applications, mechanical drive or heat and power.

References
Kaltex Altamira, Mexico
Combined heat and power plant
Customer: Energia MK KF, S.A. de C.V.
Scope: 1 x SGT-750 gas turbine

Greifswald Wingas, Germany


Combined heat and power plant
Customer: Industriekraftwerk
Greifswald GmbH, Lubmin
Scope: 1 x SGT-750 gas turbine,
automation & control for landfall
station

SGT-750 combined heat and power plant in Altamira, Mexico


32

It combines a robust, reliable design with high efficiency


and low emissions.
The SGT-750 has a track record of proven and verified
results after years in operation and several references in
both power generation and mechanical drive applications
such as pipeline and liquefied natural gas (LNG).

Power generation: 38.1 MW(e)


Mechanical drive: 39.3 MW
Maximized uptime
High efficiency
Low emissions

SGT-750 core engine with a free high-speed power


turbine

Power generation package


also available as single lift

O&G mechanical drive package for on- or


offshore applications also as single lift

Simple cycle power generation

Mechanical drive applications

Power output

38.1 MW(e)

39.3 MW

Fuel

Natural gas

Natural gas

Frequency

50/60 Hz

Gross efficiency

40.2%

41.45%

Heat rate

8,953 kJ/kWh

8,685 kJ/kWh

Turbine speed

6,100 rpm

6,100 rpm

Pressure ratio

23.8:1

23.8:1

Exhaust gas flow

~113.8 kg/s

~113.8 kg/s

Exhaust temperature

458.1C (856.5F)

458.1C (856.5F)

NOx emissions

<15 ppmvd at 15% O2 on fuel gas (with DLE)

<15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation

Physical dimensions

Siemens combined
cycle power plant

SCC-750 11

SCC-750 21

Power generation package

Mechanical drive package


76,000 kg (167,551 lb)

49.4 MW(e)

99.4 MW(e)

Approx.
weight

175,000 kg (385,809 lb)

Net power output


Net plant efficiency

52.1%

52.7%

Length

20.3 m (66.6 ft)

12.3 m (40.35 ft)

Net heat rate

6,946 kJ/kWh

6,898 kJ/kWh

Width

4.8 m (15.75 ft)

4.3 m (14.11 ft)

Number of gas turbines

Height

4.1 m (13.45 ft)

4.1 m (13.45 ft)

Note: All combined cycle is based on 2 pressure, no reheat.


Dimensions exclude inlet filter housing and exhaust stack. For power
generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

33

SGT-700
Industrial gas turbine
Thanks to its wide fuel range capability and design features,
the SGT-700 is a perfect choice for several onshore applications:
Industrial power generation, oil and gas power generation,
and mechanical drive applications.
It performs well in combined cycle plants and combined heat
and power plants.

References
Tianjin Bohai, China
Onshore simple cycle propane
dehydrogenation (PDH) plant
Customer: Tianjin Bohai Chemical
Industry Group
Scope: 2SGT-700 gas turbines and
2axial flow compressors

Pinghu/Satellite Energy
450 KTA, China
Onshore simple cycle propane
dehydrogenation (PDH) plant
Customer: Zhejiang Satellite Energy
Co., Ltd
Scope: 1 x SGT-700 gas turbine coupled
with 1 x 25 MW compressor

Three SGT-700 packages for mechanical drive


34

The SGT-700 gas turbine is an evolution of the proven


SGT-600 and is specifically designed for higher power
output. It offers easy on-site or off-site maintenance and
operates with a wide range of gaseous and liquid fuels
on Dry Low Emission (DLE).
More than 70 units have been sold with 1.2 million
equivalent operating hours, and 78,000 equivalent
operating hours for the fleet-leading gas turbine.

Power generation: 32.8 MW(e)


Mechanical drive: 33.7 MW
Robust, reliable design
High fuel flexibility
Low emissions

Maintainable, reliable, and robust twin-shaft design for mechanical drive and
power generation

For both power generation and mechanical drive package,


the driver is the same

Simple cycle power generation

Mechanical drive applications

Power output

32.8 MW(e)

33.7 MW

Fuel

Natural gas, liquid fuel, dual fuel

Natural gas, liquid fuel, dual fuel

Frequency

50/60 Hz

Gross efficiency

37.2%

38.2%

Heat rate

9,675 kJ/kWh

9,424 kJ/kWh

Turbine speed

6,500 rpm

6,500 rpm

Pressure ratio

18.7:1

18.7:1

Exhaust gas flow

95 kg/s

95 kg/s

Exhaust temperature

533C (991F)

533C (991F )

NOx emissions

15 ppmvd at 15% O2 on fuel gas (with DLE)

15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation

Physical dimensions

Siemens combined
cycle power plant

SCC-700 11

SCC-700 21

Power generation package

Mechanical drive package

Net power output

45.2 MW

91.6 MW

Approx.
weight

169,000 kg (372,581 lb)

63,000 kg (138,891 lb)

Net plant efficiency

52.3%

53.1%

Length

18.8 m (61.68 ft)

11.7 m (38.38 ft)

Net heat rate

6,876 kJ/kWh

6,778 kJ/kWh

Width

4.6 m (15.09 ft)

4.0 m (13.12 ft)

Number of gas turbines

Height

5.8 m (19.03 ft)

5.8 m (19.03 ft)

Note: All combined cycle is based on 2 pressure, no reheat.


Dimensions exclude inlet filter housing and exhaust stack. For power
generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

35

SGT-600
Industrial gas turbine
High reliability and availability in combination with good
fuel flexibility and third-generation DLE makes the SGT-600
a perfect choice for several onshore applications:
Industrial power generation, oil and gas power generation,
and mechanical drive applications. Within the IPG applications,
the turbine performs well in combined heat and power
plants and combined cycle plants.

References
Bahia Blanca, Argentina
Combined heat and power
Customer: Profertil S.A.
Scope: 1 x SGT-600 gas turbine,
STC-GV (80-6) compressor, generator,
NEM heat recovery steam generator

Tiszajvros, Hungary
Combined cycle power plant
Customer: TVK Ltd
Scope: 1 x SGT-600 gas turbine and
1 x SST-700 steam turbine

SGT-600 installation for both mechanical drive and power generation


36

The industrial gas turbine combines a robust, reliable


design with high fuel flexibility and low emissions.
More than 330 units have been sold with over 9 million
equivalent operating hours, and 185,000 equivalent
operating hours for the fleet-leading gas turbine.

Power generation: 24.5 MW(e)


Mechanical drive: 25.3 MW
Robust, reliable design
High fuel flexibility
Low emissions

Maintainable, reliable, and robust twin-shaft design for mechanical drive and
power generation

For both power generation and mechanical drive package,


the driver is the same

Simple cycle power generation

Mechanical drive applications

Power output

24.5 MW(e)

25.3 MW

Fuel

Natural gas, liquid fuel, dual fuel

Natural gas, liquid fuel, dual fuel

Frequency

50/60 Hz

Gross efficiency

33.6%

34.6%

Heat rate

10,720 kJ/kWh

10,390 kJ/kWh

Turbine speed

7,700 rpm

7,700 rpm

Pressure ratio

14.0:1

14.0:1

Exhaust gas flow

81.3 kg/s

81.3 kg/s

Exhaust temperature

543C (1,009F)

543C (1,009F)

NOx emissions

15 ppmvd at 15% O2 on fuel gas (with DLE)

15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation

Physical dimensions

Siemens combined
cycle power plant

SCC-600 11

SCC-600 21

Power generation package

Mechanical drive package

Net power output

35.9 MW(e)

73.3 MW(e)

Approx.
weight

150,000 kg (330,693 lb)

59,000 kg (130,072 lb)

Net plant efficiency

49.9%

50.9%

Length

18.8 m (61.68 ft)

11.7 m (38.38 ft)

Net heat rate

7,220 kJ/kWh

7,071 kJ/kWh

Width

4.6 m (15.09 ft)

4.0 m (13.12 ft)

Number of gas turbines

Height

5.8 m (19.03 ft)

5.8 m (19.03 ft)

Note: All combined cycle is based on 2 pressure, no reheat.


Dimensions exclude inlet filter housing and exhaust stack. For power
generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

37

SGT-500
Industrial gas turbine
Combining high overall efficiency and low maintenance
costs with long intervals between overhauls, the SGT-500
is positioned well for oil and gas power generation and
mechanical drive applications both onshore and offshore.
In addition to its proven, robust, and reliable design, the
SGT-500 has excellent fuel flexibility with the capability of

References
BUA Okpella cement plant,
Nigeria
Simple cycle power plant
Customer: BUA International Ltd.
Scope: 3SGT-500 gas turbines
High returns thanks to low
investment and operating costs,
excellent fuel flexibility, fuel
changeover on load

Two SGT-500 installations on an FPSO


38

burning heavy fuel oils (HFO), naphtha, and hydrogen


gases.
More than 175 units have been sold with over 9 million
equivalent operating hours.

Power generation: 19.1 MW(e)


Mechanical drive: 19.3 MW
Fuel flexibility
Proven design
Easily maintained

SGT-500 core engine proven and robust design

SGT-500 offshore package compact and


easily maintained

Simple cycle power generation

Mechanical drive applications

Power output

19.1 MW(e)

19.3 MW

Fuel

Natural gas, liquid, dual, HFO, crude oil

Natural gas, liquid, dual, HFO, crude oil

Frequency

50/60 Hz

Gross efficiency

33.8%

34.5%

Heat rate

10,690 kJ/kWh

10,530 kJ/kWh

Turbine speed

3,600 rpm

3,450 rpm

Pressure ratio

13.0:1

13.0:1

Exhaust gas flow

97.9 kg/s

97.9 kg/s

Exhaust temperature

369C (697F)

369C (697F)

NOx emissions

42 ppmvd at 15% O2 on fuel gas (with DLE)

42 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions
Power generation package

Mechanical drive package

Approx. weight

210,000 kg (462,970 lb)

71,000 kg (176,000 lb)

Length

20.6 m (67.6 ft)

14.1 m (46 ft)

Width

4.0 m (13.1 ft)

4.0 m (13.1 ft)

Height

3.96 m (13 ft)

3.96 m (13 ft)

Note: Dimensions exclude inlet filter housing and exhaust stack.


For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

39

SGT-400
Industrial gas turbine
The SGT-400 is a twin-shaft gas turbine available in two
different power ratings for both power generation and
mechanical drive applications.
The twin-shaft arrangement allows for commonality of
parts in mixed-duty installations.
The gas turbine offers the highest efficiency in its power
class, incorporating the latest aerodynamic and combustion
technologies.

References
Municipal utilities, Erlangen,
Germany
Combined cycle cogeneration
Customer: Erlanger Stadtwerke
Scope: 1 x SGT-400 gas turbine and
1 x SST-300 steam turbine

Bulwer Island, Brisbane,


Australia
Combined cycle power generation
Customer: Alstrom
Scope: 2SGT-400 gas turbines

The SGT-400 is available as a factory-assembled package


40

With over 25 years of operating experience, the SGT-400


is proven in both offshore and onshore applications.
Over 300 units have been sold with approximately 3 million
hours operating experience.

Power generation: 12.9/14.3 MW(e)


Mechanical drive: 13.4/14.9 MW
Latest aerodynamic and combustion
technology
Suitable for all climates, onshore
and offshore
High power-to-weight ratio

Twin-shaft design for both power generation and mechanical drive applications

Compact power generation package design

Simple cycle power generation

Mechanical drive applications

13 MW version

15 MW version

13 MW version

15 MW version

Power output

12.9 MW(e)

14.3 MW(e)

13.4 MW

14.9 MW

Fuel

Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency

50/60 Hz

50/60 Hz

Gross efficiency

34.8%

35.4%

36.2%

36.8%

Heat rate

10,355 kJ/kWh

10,178 kJ/kWh

9,943 kJ/kWh

9,774 kJ/kWh

Turbine speed

9,500 rpm

9,500 rpm

9,500 rpm

9,500 rpm

Pressure ratio

16.8:1

18.9:1

16.8:1

18.9:1

Exhaust gas flow

39.4 kg/s

44.3 kg/s

39.4 kg/s

44.0 kg/s

Exhaust temperature

555C (1,031F)

540C (1,004F)

555C (1,031F)

540C (1,004F)

NOx emissions

15 ppmvd at 15% O2 on fuel gas (with DLE)

15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions
Power generation package

Mechanical drive package

Approx. weight

83,824 kg (184,800 lb)

40,142 kg (88,500 lb)

Length

14.0 m (46 ft)

7.3 m (24 ft)

Width

3.1 m (10 ft)

3.1 m (10 ft)

Height

4.3 m (14 ft)

4.3 m (14 ft)

Note: Dimensions exclude inlet filter housing and exhaust stack.


For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

41

SGT-300
Industrial gas turbine
The SGT-300 industrial gas turbine has a rugged industrial
design that enables high efficiency, reliability, and
excellent emissions performance in a broad spectrum of
applications for both power generation and mechanical
drive.
The gas turbine is a proven unit for all electrical power
generation and cogeneration applications.

References
Over 140 units have been sold,
with more than 4.5 million equivalent
operating hours.

The SGT-300 twin-shaft version is used for mechanical drive


42

It operates on a wide range of gaseous and liquid fuels.


The compact arrangement, on-site or off-site maintainability,
and inherent reliability of the SGT-300 make it an ideal gas
turbine for the demanding oil and gas industry.

Power generation: 7.9 MW(e)


Mechanical drive: 8.2 MW
Low maintenance requirements
Low emissions
Single-shaft version for power
generation, twin-shaft version for
mechancial drive applications

Twin-shaft design evolutionary design focused on reliability

SGT-300 gas turbine package design

Simple cycle power generation

Mechanical drive applications

Power output

7.9 MW(e)

8.2 MW

Fuel

Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency

50/60 Hz

Gross efficiency

30.6%

Heat rate

11,773 kJ/kWh

10,400 kJ/kWh

Turbine speed

14,010 rpm

11,500 rpm

Pressure ratio

13.7:1

13.3:1

Exhaust gas flow

30.2 kg/s

29.0 kg/s

Exhaust temperature

542C (1,008F)

498C (924F)

NOx emissions

15 ppmvd at 15% O2 on fuel gas (with DLE)

15 ppmvd at 15% O2 on fuel gas (with DLE)

34.6%

Physical dimensions
Power generation package

Mechanical drive package

Approx. weight

59,000 kg (130,073 lb)

32,000 kg (70,548 lb)

Length

11.8 m (38.55 ft)

6.9 m (22.64 ft)

Width

2.9 m (9.35 ft)

2.9 m (9.35 ft)

Height

3.5 m (11.48 ft)

3.9 m (12.76 ft)

Note: Dimensions exclude inlet filter housing and exhaust stack.


For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

43

SGT-200
Industrial gas turbine
The rugged and compact SGT-200 gas turbine is available
as a single-shaft version for power generation, and as a
twin-shaft turbine for mechanical drive.

The SGT-200 gas turbine combines simple design with


state-of-the-art technology and is ideally suited for use,
for example, as a compressor drive.

The gas turbine operates with various gaseous and liquid


fuels. It provides high efficiency and an excellent power-toweight ratio and is available as a factory-assembled package.

More than 430 units have been sold with more than
30 million equivalent operating hours.

References
Mining industry, Jingdezhen,
China
Combined heat and power
Customer: Jingdezhen Coking Industry
Group Co. Ltd.
Scope: 2SGT-200 1S gas turbines
packaged by ZNGT
Reduced CO2 emissions, lower
operating and production costs

Rapid core engine exchange for minimized downtime


44

Power generation: 6.8 MW(e)


Mechanical drive: 7.7 MW
Robust, reliable design
Flexible fuel capability
Single-shaft and twin-shaft
options available

SGT-200 industrial gas turbine

Shop-tested and certified fluid system modules, fully wired


and with onskid controls

Simple cycle power generation

Mechanical drive applications

Power output

6.8 MW(e)

7.7 MW

Fuel

Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency

50/60 Hz

Gross efficiency

31.5%

Heat rate

11,418 kJ/kWh

10,906 kJ/kWh

Turbine speed

11,053 rpm

10,950 rpm

Pressure ratio

12.2:1

12.3:1

Exhaust gas flow

29.3 kg/s

29.5 kg/s

Exhaust temperature

466C (871F)

493C (919F)

NOx emissions

25 ppmvd at 15% O2 on fuel gas (with DLE)

15 ppmvd at 15% O2 on fuel gas (with DLE)

33%

Physical dimensions
Power generation package

Mechanical drive package

Approx. weight

56,245 kg (124,000 lb)

42,637 kg (94,000 lb)

Length

12.5 m (41 ft)

10.4 m (34 ft)

Width

2.4 m (8 ft)

2.4 m (8 ft)

Height

3.4 m (11 ft)

3.4 m (11 ft)

Note: Dimensions exclude inlet filter housing and exhaust stack.


For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

45

SGT-100
Industrial gas turbine
The SGT-100 industrial gas turbine is a proven unit for
all electrical power generation and mechanical drive
applications. The compact arrangement, on-site or off-site
maintainability, and inherent reliability make it an ideal
gas turbine for the demanding oil and gas industry.

References
Girvan, Scotland, UK
Combined heat and power
Customer: William Grant & Sons
distillery
Scope: 1 x SGT-100 gas turbine
cogeneration package
Able to provide its production process
with steam and electricity, and also to
supply electricity for the region

The SGT-100 combines advanced technology with robust construction


46

The gas turbine has a rugged industrial design that enables


high efficiency and excellent emissions performance on a
wide range of gaseous and liquid fuels.
More than 410 units have been sold with more than
24 million operating hours. The lead package has over
120,000 equivalent hours of operation.

Power generation: 5.1/5.4 MW(e)


Mechanical drive: 5.7 MW
Robust and reliable product
Wide range of gaseous and liquid fuels
Single-shaft version for power
generation or twin-shaft version for
mechanical drive applications
Robust, reliable, maintainable single-shaft version for
power generation applications

Common modular package design for


power generation

Simple cycle power generation

Common modular package design for


mechanical drive applications

Mechanical drive applications

5.1 MW version

5.4 MW version
5.4 MW(e)

Power output

5.1 MW(e)

Fuel

Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

5.7 MW

Frequency

50/60 Hz

50/60 Hz

Gross efficiency

30.2%

31.0%

32.9%

Heat rate

11,914 kJ/kWh

11,613 kJ/kWh

10,948 kJ/kWh

Turbine speed

17,384 rpm

17,384 rpm

13,000 rpm

Pressure ratio

14.0:1

15.6:1

14.9:1

Exhaust gas flow

19.5 kg/s

20.6 kg/s

19.7 kg/s

Exhaust temperature

545C (1,013F)

531C (988F)

543C (1,009F)

NOx emissions

25 ppmvd at 15% O2 on fuel gas (with DLE)

25 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions
Power generation package

Mechanical drive package

Approx. weight

61,325 kg (135,198 lb)

47,227 kg (104,117 lb)

Length

11.0 m (36.09 ft)

6.1 m (20.01 ft)

Width

2.9 m (9.35 ft)

2.9 m (9.35 ft)

Height

3.6 m (11.81 ft)

3.6 m (11.81 ft)

Note: Dimensions exclude inlet filter housing and exhaust stack.


For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

47

Aeroderivative
gas turbines
Originally developed for use in aviation, aeroderivative
gas turbines are flexible, compact, and lightweight
designs that are ideally suited for power generation
and mechanical drives in the oil and gas industry.
Their high efficiency and fast start capabilities mean
that aeroderivative gas turbines also perform well in
decentralized power generation applications.
With a fleet of 2,500 installed units, millions of
operation hours in different environments have been
generated in numerous reference projects.

Industrial Trent 60............................................................................50


Industrial RB211...............................................................................52
Industrial 501...................................................................................54

Industrial Trent 60
Aeroderivative gas turbine
Designed for industrial use in power generation and
mechanical drive applications, the Industrial Trent 60 has
established a new benchmark for power output, fuel
economy, and cost savings.
The gas turbine is highly flexible, offering high power and
efficiency with minimal drop-off at part-load and reduced

References
Bayonne, New Jersey, USA
Gas-fired power plant
Customer: Hess and ArcLight JV
Scope: 8Industrial Trent 60 WLE
ISI units

Dolphin Gas Project, Qatar


Customer: Dolphin Energy Limited
Scope: 9Industrial Trent 60 gas
turbines and 9Dresser-Rand
DATUM centrifugal compressors

Three Industrial Trent 60 units for power generation


50

speed conditions. It is available with Wet Low Emission


(WLE) and DLE combustion systems.
The Industrial Trent 60 is proven in many different
environments including arctic, desert, tropical, and coastal
in different applications ranging from peaking to base load,
simple cycle, combined cycle, and mechanical drive.

Power generation: 53.1 66.0 MW(e)


Mechanical drive: 54.2 61.8 MW
Most powerful gas turbine in its class
Flexible with high cyclic life,
fast starts
Modular package design for quick
installation and maintenance

The Industrial Trent 60 can cold-start to full power in under 10 minutes


and also has high cyclic life

Industrial Trent 60 package for power generation

Physical dimensions

Simple cycle power generation


50 Hz DLE

50 Hz DLE
with ISI

60 Hz DLE

60 Hz DLE
with ISI

50 Hz WLE
with ISI

60 Hz WLE
with ISI

Power output

53.1 MW(e)

63.5 MW(e)

54.0 MW(e)

61.8 MW(e)

66.0 MW(e)

65.7 MW(e)

Fuel

Natural gas only; other fuels on request

Frequency

50 Hz

50 Hz

60 Hz

60 Hz

50 Hz

60 Hz

Gross efficiency

42.4%

43.2%

42.5%

43.4%

41.5%

41.1%

Heat rate

8,488 kJ/kWh

8,322 kJ/kWh

8,465 kJ/kWh

8,300 kJ/kWh

8,669 kJ/kWh

8,760 kJ/kWh

Turbine speed

3,000 rpm

3,000 rpm

3,600 rpm

3,600 rpm

3,000 rpm

3,600 rpm

Pressure ratio

33.3:1

37.9:1

33.6:1

36.2:1

39.0:1

38.0:1

Exhaust gas flow

155 kg/s

177 kg/s

158 kg/s

168 kg/s

180 kg/s

172 kg/s

Exhaust temperature

433C (811F)

416C (781F)

431C (808F)

421C (790F)

416C (781F)

426C (799F)

NOx emissions

25 ppmvd at 15% O2 on fuel gas (with WLE and DLE)

Natural gas, liquid fuel, dual fuel;


other fuels on request

Power generation
package

Mechanical drive
package

Approx.
weight

208,000 kg
(458,561 lb)

105,000 kg
(231,485 lb)

Length

29.6 m (97 ft)

12.0 m (39.4 ft)

Width

4.6 m (15 ft)

4.7 m (15.4 ft)

Height

18.9 m (62 ft)

5.0 m (16.4 ft)

Combined cycle power generation


DLE 50 Hz

DLE 50 Hz
with ISI

WLE 50 Hz
with ISI

DLE 60 Hz

DLE 60 Hz
with ISI

WLE 60 Hz
with ISI

Net power output

65.3 MW(e)

77.7 MW(e)

82.9 MW(e)

66.4 MW(e)

77.5 MW(e)

80.3 MW(e)

Net plant efficiency

53.6%

53.4%

51.2%

53.5%

53.5%

50.7%

Net heat rate

6,718 kJ/kWh

6,736 kJ/kWh

7,022 kJ/kWh

6,725 kJ/kWh

6,727 kJ/kWh

7,093 kJ/kWh

Pressure/reheat

Dual/No

Dual/No

Dual/No

Dual/No

Dual/No

Dual/No

Note: Industrial Trent 60 WLE water injected. ISI Inlet Spray


Intercooling (wet compression water to the compressor).
All combined cycle performance is based on 2 pressure, no reheat.
For power generation, AC generator is included, dimensions include inlet
filter housing, exclude exhaust stack. For mechanical drive, driven equipment is excluded, dimensions exclude inlet filter housing and exhaust
stack.

51

Industrial RB211
Aeroderivative gas turbine
With class-leading reliability and availability, the Industrial
RB211 is a proven, dependable choice in power generation
and mechanical drive applications. It is qualified to meet
the stringent standards of the oil and gas industry in both
onshore and offshore service.
The aeroderivative gas generator is highly tolerant of
transient excursions and challenging mission cycles, and
can be easily exchanged at site, reducing maintenance

References
Lula (Tupi) and Guar
oilfields, offshore Brazil
Power generation in eight offshore
oil and gas FPSO vessels
Customer: Petrobras
Scope: 32Industrial RB211-GT62
generating sets

West East Pipeline, China


Gas pipeline compression station
Customer: Petro China
Scope: 30Industrial RB211 gas
turbines driving centrifugal pipeline
compressors

Two Industrial RB211 packages on an FPSO vessel


52

downtime and cost. Both conventional and DLE combustion


systems are available, including dual fuel capability.
In its 40-year evolution, the Industrial RB211 has
accumulated over 36 million equivalent operating hours,
with over 750 units sold.

Power generation: 27.2 32.5 MW(e)


Mechanical drive: 27.9 33.8 MW
Proven track record in the O&G market
Several variants to meet different
power needs
Lightweight, compact, modular package
design to maximize power density
The Industrial RB211 is a two-spool gas generator aerodynamically
coupled to a free power turbine

Modular package design to meet specifications of a wide range of


applications

Simple cycle power generation

Physical dimensions

G62 DLE

GT62 DLE

GT61 DLE

GT30 50Hz

GT30 60Hz

Power output

27.2 MW(e)

29.8 MW(e)

32.1 MW(e)

32.5 MW(e)

31.5 MW(e)

Fuel

Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency

50/60 Hz

50/60 Hz

50/60 Hz

50 Hz

Gross efficiency

36.4%

37.5%

39.3%

Heat rate

9,904 kJ/kWh

9,589 kJ/kWh

Turbine speed

4,800 rpm

Pressure ratio
Exhaust gas flow

Power generation
package

Mechanical drive
package

Approx.
weight

150,000 kg
(330,693 lb)

99,000 kg
(218,257 lb)

60 Hz

Length

16.0 m (52.49 ft)

9.2 m (30.2 ft)

37.7%

36.4%

Width

3.3 m (10.83 ft)

4 m (13.1 ft)

9,159 kJ/kWh

9,549 kJ/kWh

9,901 kJ/kWh

Height

5.4 m (17.72 ft)

5 m (16.4 ft)

4,800 rpm

4,850 rpm

3,600 rpm

3,000 rpm

20.6:1

21.7:1

21.6:1

22.7:1

22.9:1

91.0 kg/s

95.0 kg/s

94.0 kg/s

98.5 kg/s

99.8 kg/s

Exhaust temperature

501C (934F)

503C (937F)

510C (950F)

508C (946F)

512C (953F)

NOx emissions

25 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation

Net power output

G62

GT62 DLE

GT61 DLE

37.7 MW(e)

39.8 MW(e)

42.6 MW(e)

Net plant efficiency

50.2%

51.4%

52.8%

Net heat rate

7,175 kJ/kWh

7,005 kJ/kWh

6,820 kJ/kWh

Pressure/reheat

Dual/No

Dual/No

Dual/No

Note: All combined cycle is based on 2 pressure, no reheat.


For power generation, AC generator is included, dimensions exclude
inlet filter housing and exhaust stack.
For mechanical drive, driven equipment is excluded, dimensions
exclude inlet filter housing and exhaust stack.

53

Industrial 501
Aeroderivative gas turbine
Based on proven aeroderivative design, the Industrial 501
delivers high efficiency and outstanding reliability for
power generation applications like cogeneration, offshore
platforms, and emergency power. The gas turbine offers
rugged, easy-to-maintain performance due to features such
as auxiliary equipment.
The gas turbine engine is designed to operate on a wide
variety of fuels. The fuel system operations include dual

References
Grampian, Scotland
Combined heat and power plant
Customer: National Health Service,
Foresterhill Health Campus
Scope: 1 x Industrial 501-K gas turbine

Power station at Mitchelstown, Ireland


54

fuel, steam, and water injection. DLE technology is also


available.
The Industrial 501 has accumulated over 110 million
hours of operation with more than 500 customers in
53 countries.

Power generation: 3.9 6.4 MW(e)


More than 1,600 gas turbines supplied
Full power available within 60 seconds
High electrical and cycle efficiency

Industrial 501 on a test stand at Siemens facility in Mount


Vernon, Ohio, USA

Power Generation with the Industrial 501

Simple cycle power generation


Industrial 501-KB5S

Industrial 501-KB7S

Industrial 501-KH5

Power output

3.9 MW(e)

5.2 MW(e)

6.4 MW(e)

Fuel

Natural gas, liquid fuel, duel fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency

50/60 Hz

50/60 Hz

50/60 Hz

Gross efficiency

29.0%

31.5%

40.1%

Heat rate

12,393 kJ/kWh

11,445 kJ/kWh

8,971 kJ/kWh

Turbine speed

14,200 rpm

14,600 rpm

14,600 rpm

Pressure ratio

10.3:1

13.9:1

12.5:1

Exhaust gas flow

15.4 kg/s

21.1 kg/s

18.4 kg/s

Exhaust temperature

560C (1,040F)

498C (928F)

530C (986F)

NOx emissions

25 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions
Power generation package
Approx. weight

35,000 kg (85,980 lb)

Length

9 m (29.5 ft)

Width

2.7 m (8.9 ft)

Height

3.1 m (10.2 ft)

Note: Industrial 501-KH5 with case steam injection (2.73kg/s)


Dimensions exclude inlet filter housing and exhaust stack.
For power generation, AC generator is included.

55

Heavy-duty
gas turbines

Aeroderivative
gas turbines

Industrial
gas turbines

References
Siemens gas turbines are operating in more
than 60 countries.
We provide proven technology with more
than 6,750 installed heavy-duty, industrial,
and aeroderivative gas turbines.

Performance data overview


Mechanical drive applications (metric units)
Power output

Gross efficiency

Heat rate

Turbine speed

Pressure ratio

Exhaust mass flow

Exhaust temperature

SGT-750

39.3 MW

41.5%

8,685 kJ/kWh

6,100 rpm

23.8:1

113.8 kg/s

458 C

SGT-700

33.7 MW

38.2%

9,424 kJ/kWh

6,500 rpm

18.7:1

95.0 kg/s

533 C

SGT-600

25.3 MW

34.6%

10,390 kJ/kWh

7,700 rpm

14.0:1

81.3 kg/s

543 C

SGT-500

19.3 MW

34.5%

10,530 kJ/kWh

3,450 rpm

13.0:1

97.9 kg/s

369 C

SGT-400 (15 MW)

14.9 MW

36.8%

9,774 kJ/kWh

9,500 rpm

18.9:1

44.0 kg/s

540 C

SGT-400 (13 MW)

13.4 MW

36.2%

9,943 kJ/kWh

9,500 rpm

16.8:1

39.4 kg/s

555 C

SGT-300

8.2 MW

34.6%

10,400 kJ/kWh

11,500 rpm

13.3:1

29.0 kg/s

498 C

SGT-200

7.7 MW

33.0%

10,906 kJ/kWh

10,950 rpm

12.3:1

29.5 kg/s

493 C

SGT-100

5.7 MW

32.9%

10,948 kJ/kWh

13,000 rpm

14.9:1

19.7 kg/s

543 C

Industrial Trent 60 DLE

54.2 MW

43.6%

8,256 kJ/kWh

3,400 rpm

34.3:1

154.4 kg/s

440 C

Industrial Trent 60 WLE

61.8 MW

41.9%

8,592 kJ/kWh

3,400 rpm

36.1:1

164.2 kg/s

422 C

Industrial RB211 G62 DLE

27.9 MW

37.3%

9,649 kJ/kWh

4,800 rpm

20.6:1

91.3 kg/s

501 C

Industrial RB211 G62 Non-DLE

29.1 MW

37.8%

9,542 kJ/kWh

4,800 rpm

21.3:1

93.4 kg/s

500 C

Industrial RB211 GT62 DLE

30.6 MW

38.6%

9,342 kJ/kWh

4,800 rpm

21.7:1

95.4 kg/s

503 C

Industrial RB211 GT62 Non-DLE

30.9 MW

38.6%

9,338 kJ/kWh

4,800 rpm

22.0:1

96.1 kg/s

501 C

Industrial RB211 GT61 DLE

33.0 MW

40.4%

8,923 kJ/kWh

4,850 rpm

21.6:1

93.8 kg/s

510 C

Industrial RB211 GT61 Non-DLE

33.8 MW

40.4%

8,913 kJ/kWh

4,850 rpm

22.1:1

95.0 kg/s

510 C

58

58

Mechanical drive applications (imperial units)


Power output

Gross efficiency

Heat rate

Turbine speed

Pressure ratio

Exhaust mass flow

Exhaust temperature

SGT-750

39.3 MW

41.5%

8,232 Btu/kWh

6,100 rpm

23.8:1

250.9 lb/s

857 F

SGT-700

33.7 MW

38.2%

8,932 Btu/kWh

6,500 rpm

18.7:1

209.0 lb/s

991 F

SGT-600

25.3 MW

34.6%

9,848 Btu/kWh

7,700 rpm

14.0:1

179.0 lb/s

1,009 F

SGT-500

19.3 MW

34.5%

9,981 Btu/kWh

3,450 rpm

13.0:1

215.9 lb/s

697 F

SGT-400 (15 MW)

14.9 MW

36.8%

9,264 Btu/kWh

9,500 rpm

18.9:1

97.7 lb/s

1,004 F

SGT-400 (13 MW)

13.4 MW

36.2%

9,424 Btu/kWh

9,500 rpm

16.8:1

86.8 lb/s

1,031 F

SGT-300

8.2 MW

34.6%

9,857 Btu/kWh

11,500 rpm

13.3:1

63.9 lb/s

924 F

SGT-200

7.7 MW

33.0%

10,337 Btu/kWh

10,950 rpm

12.3:1

65.0 lb/s

919 F

SGT-100

5.7 MW

32.9%

10,377 Btu/kWh

13,000 rpm

14.9:1

43.4 lb/s

1,009 F

Industrial Trent 60 DLE

54.2 MW

43.6%

7,825 Btu/kWh

3,400 rpm

34.3:1

340.4 lb/s

824 F

Industrial Trent 60 WLE

61.8 MW

41.9%

8,144 Btu/kWh

3,400 rpm

36.1:1

362.0 lb/s

792 F

Industrial RB211 G62 DLE

27.9 MW

37.3%

9,145 Btu/kWh

4,800 rpm

20.6:1

201.3 lb/s

934 F

Industrial RB211 G62 Non-DLE

29.1 MW

37.8%

9,044 Btu/kWh

4,800 rpm

21.3:1

205.9 lb/s

932 F

Industrial RB211 GT62 DLE

30.6 MW

38.6%

8,855 Btu/kWh

4,800 rpm

21.7:1

210.3 lb/s

937 F

Industrial RB211 GT62 Non-DLE

30.9 MW

38.6%

8,851 Btu/kWh

4,800 rpm

22.0:1

211.9 lb/s

934 F

Industrial RB211 GT61 DLE

33.0 MW

40.4%

8,457 Btu/kWh

4,850 rpm

21.6:1

206.8 lb/s

950 F

Industrial RB211 GT61 Non-DLE

33.8 MW

40.4%

8,448 Btu/kWh

4,850 rpm

22.1:1

209.4 lb/s

950 F

59

59

Simple cycle power generation (metric units)


Power output

Frequency

Gross efficiency

Heat rate

Turbine speed

Pressure ratio

Exhaust mass flow

Exhaust temperature

SGT5-8000H

400 MW

50 Hz

40.0%

8,999 kJ/kWh

3,000 rpm

19.2:1

869.0 kg/s

627 C

SGT6-8000H

296 MW

60 Hz

40.0%

8,999 kJ/kWh

3,600 rpm

19.5:1

640.0 kg/s

630 C

SGT5-4000F

307 MW

50 Hz

40.0%

9,001 kJ/kWh

3,000 rpm

18.8:1

723.0 kg/s

579 C

SGT6-5000F

242 MW

60 Hz

39.0%

9,230 kJ/kWh

3,600 rpm

18.9:1

576.0 kg/s

600 C

SGT5-2000E

187 MW

50 Hz

36.2%

9,945 kJ/kWh

3,000 rpm

12.1:1

558.0 kg/s

536 C

116 MW

60 Hz

34.3%

10,496 kJ/kWh

3,600 rpm

12.1:1

367.0 kg/s

537 C

53.0 MW(e)

50/60 Hz

39.0%

9,231 kJ/kWh

6,608 rpm

21.4:1

137.2 kg/s

551 C

SGT6-2000E
SGT-800 (53.0 MW)
SGT-800 (50.5 MW)

50.5 MW(e)

50/60 Hz

38.3%

9,389 kJ/kWh

6,608 rpm

21.0:1

134.2 kg/s

553 C

SGT-800 (47.5 MW)

47.5 MW(e)

50/60 Hz

37.7%

9,547 kJ/kWh

6,608 rpm

20.1:1

132.8 kg/s

541 C

SGT-750

38.1 MW(e)

50/60 Hz

40.2%

8,953 kJ/kWh

6,100 rpm

23.8:1

113.8 kg/s

458 C

SGT-700

32.8 MW(e)

50/60 Hz

37.2%

9,675 kJ/kWh

6,500 rpm

18.7:1

95.0 kg/s

533 C

SGT-600

24.5 MW(e)

50/60 Hz

33.6%

10,720 kJ/kWh

7,700 rpm

14.0:1

81.3 kg/s

543 C

SGT-500

19.1 MW(e)

50/60 Hz

33.8%

10,690 kJ/kWh

3,600 rpm

13.0:1

97.9 kg/s

369 C

SGT-400 (15 MW)

14.3 MW(e)

50/60 Hz

35.4%

10.178 kJ/kWh

9,500 rpm

18.9:1

44.3 kg/s

540 C

SGT-400 (13 MW)

12.9 MW(e)

50/60 Hz

34.8%

10.355 kJ/kWh

9,500 rpm

16.8:1

39.4 kg/s

555 C

7.9 MW(e)

50/60 Hz

30.6%

11,773 kJ/kWh

14,010 rpm

13.7:1

30.2 kg/s

542 C

SGT-300
SGT-200

6.8 MW(e)

50/60 Hz

31.5%

11,418 kJ/kWh

11,053 rpm

12.2:1

29.3 kg/s

466 C

SGT-100 (5.4 MW)

5.4 MW(e)

50/60 Hz

31.0%

11,613 kJ/kWh

17,384 rpm

15.6:1

20.6 kg/s

531 C

SGT-100 (5.1 MW)

5.1 MW(e)

50/60 Hz

30.2%

11,914 kJ/kWh

17,384 rpm

14.0:1

19.5 kg/s

545 C

Industrial Trent 60 DLE

53.1 MW(e)

50 Hz

42.4%

8,488 kJ/kWh

3,000 rpm

33.3:1

155.0 kg/s

433 C

Industrial Trent 60 DLE with ISI

63.5 MW(e)

50 Hz

43.2%

8,322 kJ/kWh

3,000 rpm

37.9:1

177.0 kg/s

416 C

Industrial Trent 60 DLE

54.0 MW(e)

60 Hz

42.5%

8,465 kJ/kWh

3,600 rpm

33.6:1

158.0 kg/s

431 C

Industrial Trent 60 DLE with ISI

61.8 MW(e)

60 Hz

43.4%

8,300 kJ/kWh

3,600 rpm

36.2:1

168.0 kg/s

421 C

Industrial Trent 60 WLE with ISI

66.0 MW(e)

50 Hz

41.5%

8,669 kJ/kWh

3,000 rpm

39.0:1

180.0 kg/s

416 C

Industrial Trent 60 WLE with ISI

65.7 MW(e)

60 Hz

41.1%

8,760 kJ/kWh

3,600 rpm

38.0:1

172.0 kg/s

426 C

Industrial RB211 G62 DLE

27.2 MW(e)

50/60 Hz

36.4%

9,904 kJ/kWh

4,800 rpm

20.6:1

91.0 kg/s

501 C

Industrial RB211 GT62 DLE

29.8 MW(e)

50/60 Hz

37.5%

9,589 kJ/kWh

4,800 rpm

21.7:1

95.0 kg/s

503 C

Industrial RB211 GT61 DLE

32.1 MW(e)

Industrial RB211 GT30 50 Hz

32.5 MW(e)

Industrial RB211 GT30 60 Hz

60

50/60 Hz

39.3%

9,159 kJ/kWh

4,850 rpm

21.6:1

94.0 kg/s

510 C

50 Hz

37.7%

9,549 kJ/kWh

3,000 rpm

22.7:1

98.5 kg/s

508 C

31.5 MW(e)

60 Hz

36.4%

9,901 kJ/kWh

3,600 rpm

22.9:1

99.8 kg/s

512 C

Industrial 501 (6.4 MW)

6.4 MW(e)

50/60 Hz

40.1%

8,971 kJ/kWh

14,600 rpm

12.5:1

18.4 kg/s

530 C

Industrial 501 (5.2 MW)

5.2 MW(e)

50/60 Hz

31.5%

11,445 kJ/kWh

14,600 rpm

13.9:1

21.1 kg/s

498 C

Industrial 501 (3.9 MW)

3.9 MW(e)

50/60 Hz

29.0%

12,393 kJ/kWh

14,200 rpm

10.3:1

15.4 kg/s

560 C

60

Simple cycle power generation (imperial units)


Power output

Frequency

Gross efficiency

Heat rate

Turbine speed

Pressure ratio

Exhaust mass flow

Exhaust temperature

SGT5-8000H

400 MW

50 Hz

40.0%

8,530 Btu/kWh

3,000 rpm

19.2:1

1,915.0 lb/s

1,161 F

SGT6-8000H

296 MW

60 Hz

40.0%

8,530 Btu/kWh

3,600 rpm

19.5:1

1,410.0 lb/s

1,166 F

SGT5-4000F

307 MW

50 Hz

40.0%

8,532 Btu/kWh

3,000 rpm

18.8:1

1,595.0 lb/s

1,074 F

SGT6-5000F

242 MW

60 Hz

39.0%

8,748 Btu/kWh

3,600 rpm

18.9:1

1,270.0 lb/s

1,113 F

SGT5-2000E

187 MW

50 Hz

36.2%

9,427 Btu/kWh

3,000 rpm

12.1:1

1,230.0 lb/s

997 F

SGT6-2000E

116 MW

60 Hz

34.3%

9,949 Btu/kWh

3,600 rpm

12.1:1

809.0 lb/s

999 F

SGT-800 (53.0 MW)

53.0 MW(e)

50/60 Hz

39.0%

8,749 Btu/kWh

6,608 rpm

21.4:1

302.5 lb/s

1,024 F

SGT-800 (50.5 MW)

50.5 MW(e)

50/60 Hz

38.3%

8,899 Btu/kWh

6,608 rpm

21.0:1

295.8 lb/s

1,027 F

SGT-800 (47.5 MW)

47.5 MW(e)

50/60 Hz

37.7%

9,048 Btu/kWh

6,608 rpm

20.1:1

292.8 lb/s

1,007 F

SGT-750

38.1 MW(e)

50/60 Hz

40.2%

8,486 Btu/kWh

6,100 rpm

23.8:1

250.9 lb/s

856.5 F

SGT-700

32.8 MW(e)

50/60 Hz

37.2%

9,170 Btu/kWh

6,500 rpm

18.7:1

209.0 lb/s

991 F

SGT-600

24.5 MW(e)

50/60 Hz

33.6%

10,161 Btu/kWh

7,700 rpm

14.0:1

179.0 lb/s

1,009 F

SGT-500

19.1 MW(e)

50/60 Hz

33.8%

10,132 Btu/kWh

3,600 rpm

13.0:1

215.9 lb/s

697 F

SGT-400 (15 MW)

14.3 MW(e)

50/60 Hz

35.4%

9,647 Btu/kWh

9,500 rpm

18.9:1

97.7 lb/s

1,004 F

SGT-400 (13 MW)

12.9 MW(e)

50/60 Hz

34.8%

9,815 Btu/kWh

9,500 rpm

16.8:1

86.8 lb/s

1,031 F

SGT-300

7.9 MW(e)

50/60 Hz

30.6%

11,158 Btu/kWh

14,010 rpm

13.7:1

66.6 lb/s

1,008 F

SGT-200

6.8 MW(e)

50/60 Hz

31.5%

10,822 Btu/kWh

11,053 rpm

12.2:1

64.5 lb/s

871 F

SGT-100 (5.4 MW)

5.4 MW(e)

50/60 Hz

31.0%

11,007 Btu/kWh

17,384 rpm

15.6:1

45.4 lb/s

988 F

SGT-100 (5.1 MW)

5.1 MW(e)

50/60 Hz

30.2%

11,292 Btu/kWh

17,384 rpm

14.0:1

43.1 lb/s

1,013 F

Industrial Trent 60 DLE

53.1 MW(e)

50 Hz

42.4%

8,045 Btu/kWh

3,000 rpm

33.3:1

342.0 lb/s

811 F

Industrial Trent 60 DLE with ISI

63.5 MW(e)

50 Hz

43.2%

7,888 Btu/kWh

3,000 rpm

37.9:1

390.0 lb/s

781 F

Industrial Trent 60 DLE

54.0 MW(e)

60 Hz

42.5%

8,023 Btu/kWh

3,600 rpm

33.6:1

348.0 lb/s

808 F

Industrial Trent 60 DLE with ISI

61.8 MW(e)

60 Hz

43.4%

7,867 Btu/kWh

3,600 rpm

36.2:1

370.0 lb/s

790 F

Industrial Trent 60 WLE with ISI

66.0 MW(e)

50 Hz

41.5%

8,217 Btu/kWh

3,000 rpm

39.0:1

397.0 lb/s

781 F

Industrial Trent 60 WLE with ISI

65.7 MW(e)

60 Hz

41.1%

8,303 Btu/kWh

3,600 rpm

38.0:1

379.0 lb/s

799 F

Industrial RB211 G62 DLE

27.2 MW(e)

50/60 Hz

36.4%

9,387 Btu/kWh

4,800 rpm

20.6:1

200.6 lb/s

934 F

Industrial RB211 GT62 DLE

29.8 MW(e)

50/60 Hz

37.5%

9,089 Btu/kWh

4,800 rpm

21.7:1

209.4 lb/s

937 F

Industrial RB211 GT61 DLE

32.1 MW(e)

50/60 Hz

39.3%

8,681 Btu/kWh

4,850 rpm

21.6:1

207.2 lb/s

950 F

Industrial RB211 GT30 50 Hz

32.5 MW(e)

50 Hz

37.7%

9,051 Btu/kWh

3,000 rpm

22.7:1

217.2 lb/s

946 F

Industrial RB211 GT30 60 Hz

31.5 MW(e)

60 Hz

36.4%

9,384 Btu/kWh

3,600 rpm

22.9:1

220.0 lb/s

953 F

Industrial 501 (6.4 MW)

6.4 MW(e)

50/60 Hz

40.1%

8,503 Btu/kWh

14,600 rpm

12.5:1

40.6 lb/s

986 F

Industrial 501 (5.2 MW)

5.2 MW(e)

50/60 Hz

31.5%

10,848 Btu/kWh

14,600 rpm

13.9:1

46.5 lb/s

928 F

Industrial 501 (3.9 MW)

3.9 MW(e)

50/60 Hz

29.0%

11,746 Btu/kWh

14,200 rpm

10.3:1

34.0 lb/s

1,040 F

61

61

Published by
Siemens Energy, Inc.
Power and Gas Division
4400 Alafaya Trail
Orlando, FL 32826-2399, USA
For more information, please contact
our Customer Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
Email: support.energy@siemens.com
Article-No. PGDG-B10006-00-4AUS
Printed in Germany
Dispo 34806 BR 11152.0

Subject to changes and errors. The information given in


this document only contains general descriptions and/or
performance features which may not always specifically
reflect those described, or which may undergo modification
in the course of further development of the products. The
requested performance features are binding only when
they are expressly agreed upon in the concluded contract.

You might also like