1.0 Packaged Air Cooled Rotary Screw Water


Chillers
Supply, Installation and setting to work including all
required field wiring in rigid metal conduit from
Chiller panel to local isolators, condenser anti
corrosion coatings, spring vibration isolators,
electrical isolators temperature controllers, testing
and commissioning etc. as per equipment schedule

Refrigerant : R- HFC 134 A


1.1 ACWC-01 capacity 00 ton / 00 GPM No. -
1.2 ACWC-02 capacity 00 ton /00 GPM (STD BY) No. -

2.0 Chilled Water AHU


Supply, Installation and setting to work including all
required field wiring in rigid metal conduit from AHU
panel to local isolators, condenser anti corrosion
coatings, spring vibration isolators, electrical
isolators temperature controllers, testing and
commissioning etc. Complete (modulating 3 way
valve temperature controls) as per equipment
schedule

2.1 AHU-1 capacity 25 ton No. -


2.2 AHU-2 capacity 30 ton No. -

3.0 Chilled Water Pump Set


Supply, installation and setting to work including all
required field wiring, galvanized rigid metal conduit
from Pump panel to local isolator & from Pump to
Pump panel, electrical isolator, pump control panel,
controls, spring type vibration isolators testing and
commissioning etc., as per equipment schedule

3.1 CWPP-01 to 00 capacity 00 GPM @ 00 meter head No. -


(00 duty + 01 std by)
3.2 CWSP-01 to 00 capacity 00 GPM @ 00 meter head No. -
(00 duty + 01 std by)

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 1of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

4.0 Roof Top Package Units:


Supply, lift into position, install, test, set to work,
and commission weatherproof Package Units, Units
shall be complete with internal & external. Anti
vibration mounts, and a spare set of filters shall be
installed after commissioning. Installation shall
include all required field wiring, power wiring from
an adjacent disconnect switch (supplied and
installed by others), weatherproof cables,
galvanized rigid metal conduits, condensate drain,
complete. operating at 380/3/60 Hz power supply
including thermostat and as specified in the
equipment schedule. Package unit time delay to be
adjusted by the contractor.

4.1 Capacity 30 ton / 12000 CFM No. 820,000.00 -


4.2 Capacity 25 ton / 10000 CFM No. 73,000.00 -
4.3 Capacity 20 ton / 8000 CFM No. 60,000.00 -
4.4 Capacity 15 ton / 6000 CFM No. 45,500.00 -
4.5 Capacity 10 ton / 4000 CFM No. 30,000.00 -

5.0 DX Type Air Conditioning Unit


Supply, lift into position, install, test, set to work,
and commission DX type (mini-split A/C unit &
ducted-split A/C unit) complete with thermostat with
ACU outside, Installation shall include all required
field control wiring, power wiring from an adjacent
disconnect switch (supplied and installed by others),
weatherproof cables, galvanized rigid metal
conduits, refrigerant pipes and insulation, support
for ACCU, etc, complete to set to work (as specified
in the drawing). Out door refrigerant pipe shall have
canvas with two coats of foster paint and supported
by cable trays. All units to be suitable for externally
locating and Nominal capacities indicated.

5.1 Ducted Split Air Conditioning Unit


5.1.1 Capacity 5 ton No. 22,500.00 -
5.1.2 Capacity 4 ton No. 18,600.00 -
5.1.3 Capacity 3 ton No. 14,500.00 -
5.1.4 Capacity 2.5 ton No. 12,000.00 -
5.1.5 Capacity 2.0 ton No. 9,500.00 -
5.1.6 Capacity 1.5 ton No. 7,300.00 -

09/24/2010 40655422.xlsHVAC Page 2of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

To Bill Summary

5.2 Ducted Split Air Conditioning Unit


5.2.1 Capacity 2.0 ton No. 6,000.00 -
5.2.2 Capacity 1.5 ton No. 5,000.00 -
No.
5.3 Window AC No.
5.3.1 1.5 Tons No. 3,500.00 -

6.0 Extract Air Fans


Supply, lift into position, install, test, set to work and
commission Extract Air Fans. The Fan Units shall
have Anti-back draught shutters & internal Anti
vibration mounts. Installation shall include all
required power wiring from an adjacent disconnect
switch weatherproof cables, galvanized rigid metal
conduits, etc., complete. All fans are centrifugal and
roof mounted and wall fans are wall mounted.

6.1 EF-01 capacity 00 CFM @ 00" static (Roof top) No. -


6.2 EF-02 capacity 00 CFM @ 00" static (Inline) No. -
6.3 EF-03 capacity 100 CFM (wall mounted) No. -

7.0 Air curtains


Supply, lift into position, install, test, set to work and No. -
commission air curtains operating at 230/1/60 Hz
power supply, capacity 00 CFM as per equipment
schedule, from Mars or equal manufacturer

8.0 Duct Works


8.1 Supply, installation and setting to work ductwork as
per SMACNA Standards including full sealing of all
joints, Rectangular volume control dampers,
galvanized hangers and supports, leak testing, air
balancing and testing and commissioning etc.,
complete For Air Conditioned Air & Exhaust air.

8.1.1 20 GAUGE m2 185.00 -


8.1.2 22 GAUGE m2 160.00 -
8.1.3 24 GAUGE m2
145.00 -
8.1.4 26 GAUGE m2
140.00 -

8.2 Supply and installation Aluminum cladding 0.6 mm m2 125 -


thickness to exposed supply & return ducts
including full sealing of all joints

09/24/2010 40655422.xlsHVAC Page 3of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 4of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

8.3 Supply and installation Supply and installation m2 50 -


Acoustic lining fiber glass 25mm thick to supply and
return duct up to 5 meter length and of density 24
kg / m3 from AFICO or equal

8.4 Supply and installation Fiber glass Insulation 50mm m2 65 -


thick 48 kg / m3 density from AFICO or equal to
exposed supply & return ducts

8.5 Supply and installation Fiber glass Insulation 25mm m2 40 -


thick 24 kg / m3 density from AFICO or equal to
indoor supply & return duct

8.6 Supply, installation and setting to work Flexible


duct1.2m long as per SMACNA Standards including
full sealing of all joints, Round volume control
dampers, galvanized hangers and supports, leak
testing, air balancing and testing and commissioning
etc., complete For Air Conditioned Air & Exhaust
air. as per drawings. from SAFID or equal
manufacturer

8.6.1 250 mm (10 Inch) diameter No. 135 -


8.6.2 200 mm (8 Inch) diameter No. 125 -
8.6.3 150 mm (6 Inch) diameter No. 115 -

9.0 Air Distributing Equipment

9.1 Supply and install Supply air Ceiling Diffuser SCD


with internally insulated plenum boxes as per
drawings. from GGC or equal
9.1.1 600 x 600 mm (24 x 24) Inch No. 650 -
9.1.2 450 x 450 mm (18 x 18) Inch No. 500 -
9.1.3 300 x 300 mm (12 x 12) Inch No. 350 -
9.1.4 225 x 225 mm (9 x 9) Inch No. 300 -
9.1.5 150 x 150 mm (6 x 6) Inch No. 250 -

9.2 Supply and install Return air Ceiling Diffuser RCD,


with internally insulated plenum boxes unless it is
not connected to return duct, as per drawings. from
GGC or equal
9.2.1 600 x 600 mm (24 x 24) Inch No. 450 -
9.2.2 450 x 450 mm (18 x 18) Inch No. 350 -
9.2.3 300 x 300 mm (12 x 12) Inch No. 225 -
9.2.4 225 x 225 mm (9 x 9) Inch No. 175 -
9.2.5 150 x 150 mm (6 x 6) Inch No. 150 -

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 5of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

09/24/2010 40655422.xlsHVAC Page 6of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

9.3 Supply and install Exhaust air Ceiling Diffusers ECD


with plenum boxes internally insulated, as per
drawings. from GGC or equal
9.3.1 225 x 225 mm (9 x 9) Inch No. 275 -
9.3.2 150 x 150 mm (6 x 6) Inch No. 210 -

9.4 Supply and install Supply Linear Slot Diffusers LSD


including plenum boxes with internally insulation, as
per drawings. from GGC or equal
9.4.1 2 slot x 1 m No. -
9.4.2 3 slot x 1 m No. -

9.5 Supply and install Linear Bar air Supply Grill LBSG
including plenum boxes with internally insulation as
per drawings. from GGC or equal
9.5.1 1000 x 150 mm No. -
9.5.2 1500 x 200 mm No. -

9.6 Supply and install Return Linear Slot Diffusers RLSD


including plenum boxes with internally insulation
unless it is not connected to a return duct, as per
drawings. from GGC or equal
9.6.1 2 slot x 1 m No. -
9.6.2 3 slot x 1 m No. -

9.7 Supply and install Linear Bar air Return Grill LBRG
including plenum boxes with internally insulation
unless it is not connected to a return duct, as per
drawings. from GGC or equal
9.7.1 1000 x 150 mm No. -
9.7.2 1500 x 200 mm No. -

9.8 Supply and install Intake air Sand Trap Louver STL
as per drawings. from GGC or equal
9.8.1 2000 x 600 mm No. -

9.8 Supply and install Exhaust air Sand Trap Louver


ESTL as per drawings. from GGC or equal
9.8.1 2000 x 600 mm No. -

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 7of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

09/24/2010 40655422.xlsHVAC Page 8of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

10.0 Chilled Water Pipe works


10.1 Supply, installation and setting to work chilled water
pipes and fittings including galvanized hangers and
supports, vibration isolators, expansion joints, thrust
block, pressure testing, system testing and
commissioning all necessary accessories to finalize
work

10.1.1 300 mm (12 Inch) dia. black steel sch. 40 ERW m -


10.1.2 250 mm (10 Inch) dia. black steel sch. 40 ERW m -
10.1.3 200 mm (8 Inch) dia. black steel sch. 40 ERW m -
10.1.4 150 mm (6 Inch) dia. black steel sch. 40 ERW m -
10.1.5 100 mm (4 Inch) dia. black steel sch. 40 ERW m -
10.1.6 75 mm (3 Inch) dia. black steel sch. 40 ERW m -
10.1.7 65 mm (2 ½ Inch) dia. black steel sch. 40 ERW m -
10.1.8 50 mm (2 Inch) dia. black steel sch. 40 ERW m -
10.1.9 40 mm (1 ½ Inch) dia. black steel sch. 40 ERW m -
10.1.1 32 mm (1¼ Inch) dia. black steel sch. 40 ERW m -
0
10.1.1 25 mm (1 Inch) dia. black steel sch. 40 ERW m -
1
10.2 Supply, installation and setting to work exposed
chilled water pipes and fittings including galvanized
hangers and supports, vibration isolators, expansion
joints, thrust block, pressure testing, system testing
and commissioning and all necessary accessories to
finalize work

10.2.1 300 mm (12 Inch) dia. black steel sch. 40 ERW m -


10.2.2 250 mm (10 Inch) dia. black steel sch. 40 ERW m -
10.2.3 200 mm (8 Inch) dia. black steel sch. 40 ERW m -
10.2.4 150 mm (6 Inch) dia. black steel sch. 40 ERW m -
10.2.5 100 mm (4 Inch) dia. black steel sch. 40 ERW m -
10.2.6 75 mm (3 Inch) dia. black steel sch. 40 ERW m -
10.2.7 65 mm (2 ½ Inch) dia. black steel sch. 40 ERW m -
10.2.8 50 mm (2 Inch) dia. black steel sch. 40 ERW m -
10.2.9 40 mm (1 ½ Inch) dia. black steel sch. 40 ERW m -
10.2.1 32 mm (1¼ Inch) dia. black steel sch. 40 ERW m -
0
10.2.1 25 mm (1 Inch) dia. black steel sch. 40 ERW m -
1

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 9of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

09/24/2010 40655422.xlsHVAC Page 10of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

Supply and install Thermal insulation to chilled


water pipework. minimum density 64 kg/m3 pre-
formed rigid fiber glass Thermal Insulation with
10.3 factory applied foil reinforced Kraft laminate facing
& 0.6 mm thick aluminium cladding for the external
pipes

10.3.1 300 mm (12 Inch) dia. black steel sch. 40 ERW m -


10.3.2 250 mm (10 Inch) dia. black steel sch. 40 ERW m -
10.3.3 200 mm (8 Inch) dia. black steel sch. 40 ERW m -
10.3.4 150 mm (6 Inch) dia. black steel sch. 40 ERW m -
10.3.5 100 mm (4 Inch) dia. black steel sch. 40 ERW m -
10.3.6 75 mm (3 Inch) dia. black steel sch. 40 ERW m -
10.3.7 65 mm (2 ½ Inch) dia. black steel sch. 40 ERW m -
10.3.8 50 mm (2 Inch) dia. black steel sch. 40 ERW m -
10.3.9 40 mm (1 ½ Inch) dia. black steel sch. 40 ERW m -
10.3.10 32 mm (1 ¼ Inch) dia. black steel sch. 40 ERW m -

11.0 Chilled Water Valves and Accessories


11.1 Supply, install, set to work and commission all Item -
necessary sundries, supports, etc., complete

11.2 Supply, install, set to work and commission chemical Item -


dosing pot assembly (00 litres) including 1" dia. ball
valves for filling, inlet line, outlet line, and drain.
Filling funnel with cap, automatic air vent with cock,
and all other accessories needed to finalise the work
as per drawings. From METITO or equal

11.3 Air Separator including gate valves for inlet, outlet


and by-pass, automatic air vent with cock, drain
valve, and othe accessories needed to finalise the
work as per drawings. From TACO or equal

11.3.1 250 mm dia inlet/outlet connection No. -


11.3.2 Expansion tank 00 liters, bladder type similar or No. -
equal to TACO

11.4 Valves and Pipeline Ancillaries


11.4.1 Supply, install, set to work and commission all 1 Item -
valves and pipeline ancillaries etc. complete. From
Nibco/Crane/Bell & Gossette

11.5 32 mm dia. water supply isolation valve for make-up No. -


water
11.6 25 mm dia. Isolating gate valves - for dosing pot No. -
11.7 15 mm dia. drain valve for dosing pot No. -

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 11of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

09/24/2010 40655422.xlsHVAC Page 12of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

11.8 25 mm dia. drain valve No. -


11.9 100 mm dia. check valves No. -
11.10 100 mm dia. butterfly valve No. -
11.11 50 mm dia. pressure relief valve No. -
11.12 150 mm dia. facia pressure gauge & gauge ports No. -
11.13 100 mm dia. pipeline Y - Strainer No. -
11.14 15 mm dia. Automatic air vent No. -
11.15 100 mm dia. flexible connectors for the pump (to be No. -
pump connection size)

12.0 Chilled water pump valves and accessories


12.1 15 mm dia. drain valve No. -
12.2 150 mm dia. triple duty valve No. -
12.3 50 mm dia. pressure relief valve No. -
12.4 150 mm dia. butterfly valve No. -
12.5 100 mm dia. check valves No. -
12.6 150 mm dia. Y-Strainer No. -
12.7 150 mm dia. fascia pressure gauge No. -
12.8 100 mm dia. flexible connectors for the pump (to be No. -
pump connection size)

13.0 Flushing and Water Treatment Chemicals


Supply, installation and setting to work including all Item -
necessary sundries, water requirement and proper
waste water disposal, laboratory test, etc.,
complete. From Metito or equal

14.0 Supply, installation, test and setting to work item -


condensate drain piping of AC machines connected
to nearest drain point with fittings and accessories
completely

AA Mechanical Identification:
Supply and install approved services identification item -
tags, markings and flow direction arrows.

BB Civil Works
Provide for associated civil works required for the job -
Mechanical Services Installation as described and
listed in this B of Q and as shown on the drawings.
The works shall include the formation of all holes for
the services to pass through etc., and the sealing of
the holes once the services have been installed.
Provide structural supports / framing for the WU, EU
& ACU, EF at height such as to allow for the
installation of P- trap for condensate drain lines.

To Bill Summary

09/24/2010 40655422.xlsHVAC Page 13of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

BILL SUMMARY

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 1 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 2 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 3 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 4 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 5 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 6 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 7 of 8

00 -Bill #00 -Div.15 -HVAC -Rev.0 -Page 8 of 8

09/24/2010 40655422.xlsHVAC Page 14of15


BILLS OF QUANTITIES
PROJECT NAME SAK ENGINEERING CONSULTANTS
LOCATION Bill No. - 00 (Rev. 0)
BUILDIONG NAME DIVISION - 15 - Mech. Works (HVAC)

Unit Price Amount


Ref. DESCRIPTION Quantit Unit SR SR
y

To General Summary

09/24/2010 40655422.xlsHVAC Page 15of15

You might also like