Professional Documents
Culture Documents
Weighing Electronics
Stand-Alone Integrators
Milltronics BW100
■ Dimensional drawings
■ Schematics
Terminal Block
AC Supply
4 + SIG A 20 + EXC
5 CNST. SPD. 21 shield
6 COM. 22 TX1
speed
7 + SIG 23 TX2 comm
port
8 + EXC 24 RX1
9 + auto 25 RX2
zero
10 26 dc
11 shield 27 + total (1)
12 28 + mA
dc/ac
13 total (2) 29 output
14 N.O. 30 31
24 V
15 COM alarm 31 L2/N 32 +
16 N.C. 32 L1
31
12 V
32 +
Interconnection
All field wiring must have insulation for at least 250 V.
DC terminals shall be supplied from an SELV source in accordance
with IEC-1010-1 Annex H.
For DC versions TB#31 is used for negative (-) and TB#32 is used
for positive (+) connection.
Non-metallic enclosure does not provide grounding between connections.
Use grounding type bushings and jumpers.