Technical Specitcatons + PICTURE ‘ SWITCH 10A 1 GANG 1 WAY “© SWITCH 10A 2 GANG | WAY * SWITCH 1043 GANG 1 WAY yr Technical Speciications ¢» SWITCH 10A | GANG 2 WAY | | | 4, SOCKET OUTLETS in, 15A or 20A as shown on the Sub-Sub-Contract -outlet Socket outlets shall be 3+ Drawings. Two-pole and earthing-pin plugs, socket-outlets and sox ke adaptors and 20A plugs, socket-outlets and adaptors, where applicable. Tor socket outlets in plant rooms and switchrooms, switch socket outlets shall be surface mounting metal clad type and mounted at 1400mm. Socket outlets for emergency supplies shall have red coloured indicator lamps shall re rove wel and area susceptible to presence of water, socket outlets shall be of the rerwise stated oF weatherproof type uniess ot the Sub-Contract Drawings. The live metal parts shall be recessed below the surface to eliminate the danger of touch ntact, A brass screw cap with chain attachment shall be provided for the socket chem it is not in use, 20 amp. switched socket outlets shall be supplied from the ‘fistribution boards and not more than one such outlet will be permitted per circu These will be, unless otherwise stated, installed using 4mm? cables, in the form of a | radial circuit... | be provided where specified red coloured rocker switches Technical Specifications + PICTURE ‘+ POWER DOUBLE SOCKET, IN SLAB WALL TYPE, EARTH TERMIN. 2PRSOV/ISA Technical Specifications 5. TELEPHONE / DATA OUTLETS Telephone and data cable outlets shall comprise a deep conduit box complying with Specification for boxes for boxes for the enclosure of electrical accessories flush mounted in walls. The cover plate shalll be of the moulded type and of white or ivory colour. + PICTURE + DATA MODULER JACK ** VOICE MODULER JACK Technica Specitiations ‘+ TELEVISION JACK 6. MINIATURE CIRCUIT BREAKERS (M.C.B.) Single pole miniature circuit breakers shall be used for sub-circuit control and prolection an al lighting and small power circuits. Three-pole breakers shall be used for three-phase equipment. M.C-Bs shall be single-pote or three-pole only and neutral link switching is not required. The body and base of the units shall be moulded Bakelite or similar material and Units shall be sealed after assembly. The load handling contracts shall be silver/tungsten and the contracts and operating mechanism so designed as o give a wiping action both at make break ‘The breaker operating mechanism shall be the trip-free type so designed as to Prevent the load handling contracts from closing on a fault Circuit protection against overload and fault conditions shall be provided by means of a thermal magnetic device designed to give thermal operation on overload and ‘magnetic operation under fault conditions, Positions ofthe breaker operating dolly shall be clearly indicated The Uipping characteristics shall be suitable for the type of load connected. All cable and busbar terminations shall be sweated and tinned prior to connection to. M.C.B. terminals, B 1 Technical Specifications + PICTURE + MCCB 3P/63A/25KA “ MCCB 2P/40A/6KA Technical Specifications “MCB 1P/10A/4.5KA 7. DISTRIBUTION BOARDS Miniature circuit breaker distribution boards shall be provided to serve lighting Circuits, ‘small power outlets and/or as otherwise specified on the Sub-Contract Drawings. The number of way shown on the Sub-Contract Drawings shall be provided Al wiring, busbars, etc. within the distribution boards shall be screened behind a & 5mm thick flame retardant insulating shield. Only the M.C.B. operating dolly and insulated body shall project through the shield Connection blocks used for branching live feed cables inside distibution boards shall include one insulated support, brass connection blocks with removable anti- shear plates to enable cables to be connected without cutting, if necessary and preferably t be fixed on DIN rails. The rating ofthe connection blocks shall be not less than the tating of the incoming circuit breaker. Bakelite Insulated i) connectors used shall be PUB-approved type. Comb busbars are permitted for use in disteibution boards for residential premises only. It shall also be restricted to single-phase distribution boards and hott not exceed 100A rating. PSB certification of the comb busbar current ra ing shall be submitted.

You might also like