You are on page 1of 4
RESERVOI nove: 50232SL ASSEMBLY_ INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS 1ons. WAY THROUGH PRIOR TO ASSEMBLY. ‘THIS FOUNTAIN SHOULD TAKE APPROXIMATELY 40 MINUTES 10 ASSEMBLE. MAKE SURE ALL PARTS ARF FIRMLY TIGHTENED, ‘CAUTION: HEAVY SLATE FOUNTAIN ‘TWO PEOPLE REQUIRED TO LIFT AND ASSEMBLE ‘THIS FOUNTAIN INCLUDE 50232SL_AND_ 50232SLB0x2, '50252SL_AND 50232SLBOX2 ARE SOLD SEPARATELY. UNPACK THE FOUNTAIN ‘YOU SHOULD HAVE RECEIVED THE FOLLOWING PARTS IN THE BOX OF $0232SL: UPPER FOUNTAIN BODY, MIDDLE FOUNTAIN BODY, UPPER METAL BRANCH, MIDDLE METAL BRANCH AND LOWER METAL BRANCH. YOU SHOULD HAVE RECEIVED THE FOLLOWING PARTS IN THE BOX OF 50232SLBOX2: LOWER FOUNTAIN BODY, RESERVOIR, SPOT LIGHT, (2) EXTRA MR—11 BULES, TRANSFORMER, PUMP, SPOT LIGHT’ HOLDER AND A BAG OF RIVER STONES. FOUNTAIN ASSEMBLY 1. PLACE SPOT LIGHT AND PUMP INTO RESERVOIR, THEN RUN LIGHT POWER CORD AND PUMP POWER CORD UP AND OVER BACK OF RESERVOIR. UMP. POWER CORD ume r PUMP2011 (repLacewent | bl PART) \ th IgHT POWER CORD sror Lee ty V ero 2. REMOVE (2) LARGE SCREWS AND (2) METAL WASHERS FROM RESERVOIR, PLACE LOWER FOUNTAIN BODY INTO RESERVOIR, THEN SECURE WITH (2) METAL WASHERS AND (2) LARGE SCREWS REMOVED ABOVE. Lower |_FounTaIn BODY LARGE SCREW (2 Pcs) METAL WASHER (2 Pcs) RESERVOIR 3. INSERT PINS OF MIDDLE FOUNTAIN BODY INTO HOLES OF THE LOWER FOUNTAIN BODY, THEN SECURE WITH (2) SMALL SCREWS FROM BACK OF THE LOWER FOUNTAIN BODY. MiDDLe |-——FOUNTAN, BODY IN (2 PCS) MALL SCREW (2 Pcs) LOWER |—FounTaNn BODY 50232SL INSTRUCTIONS (PAGE 1/4) wove 5O0232SL ASSEMBLY_|NSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS 4. INSERT PINS OF UPPER FOUNTAIN BODY INTO HOLES OF THE MIDDLE FOUNTAIN BODY, THEN SECURE WITH (2) SMALL SCREWS FROM BACK OF THE MIDDLE FOUNTAIN BODY. JPPER FOUNTAIN BoDy IN (2 PCS) SMALL SCREW (2 Pcs) MIDoLE ‘OUNTAIN BODY 5. SECURE THE RUBBER HOSE TO BACK OF THE FOUNTAIN BODY WITH CLIP. THEN FEED THE RUBBER HOSE THROUGH HOLE IN LOWER FOUNTAIN BODY. 4[+rountan Boo LP {UBBER HOSE |-—Lower a FOUNTAIN BODY 9/10 6. To PREVENT FOUNTAIN FROM TILTING, IT CAN BE ATTACHED TO THE WALL. MEASURE DISTANCE FROM FLOOR TO CHAINS ON BACK OF THE FOUNTAIN. 7. SECURE FOUNTAIN TO WALL WITH CHAIN. (HARDWARE NOT INCLUDED. CONTACT YOUR LOCAL HARDWARE PROFESSIONAL TO CHOOSE AN ATTACHMENT MECHANISM APPROPRIATE FOR YOUR WALL) IMPORTANT NOTE: FOUNTAIN BODY MUST SIT ON FLOOR, NOT HANG ON WALL. i — [-—FouNTAN BooY 8. ATTACH PUMP TO RUBBER HOSE AND PLACE THE PUMP FLAT IN RESERVOIR. RESERVOIR—y RUBBER HOSE- Puwi 50232SL INSTRUCTIONS (PAGE 2/4) wove: SO0232SL ASSEMBLY_ INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Q. IF OPTIONAL METAL BRANCHES ARE BEING USED, FOLLOW THE INSTRUCTIONS AS BELOW. IF USE OF METAL BRANCHES ARE NOT DESIRED, SKIP TO STEP #13. 10. REMOVE NUT FROM NIPPLE, INSERT NIPPLE OF LOWER METAL BRANCH INTO HOLE IN LOWER FOUNTAIN BODY AND SECURE WITH THE NUT. MAKE SURE THE HOOKS ARE INSERTED INTO THE LOOPS ON FRONT OF FOUNTAIN BODY. HOOK: FOUNTAIN BODY. LOWER METAL BRANCH Loor i i f= ( \ NIPPLE NUT 11. INSERT PIN OF MIDDLE METAL BRANCH INTO HOLE OF LOWER METAL BRANCH. MAKE SURE THE HOOKS ARE INSERTED INTO THE LOOPS ON FRONT OF FOUNTAIN BODY. MIODLE ETAL ‘BRANCH HooK- oop |-—FounTann oDy Lower METAL BRANC! 12. INSERT PIN OF UPPER METAL BRANCH INTO HOLE OF MIDDLE METAL BRANCH. MAKE SURE THE HOOKS ARE INSERTED INTO THE LOOPS ON FRONT OF FOUNTAIN BODY. 00? FOUNTAIN BODY. 13. FILL RESERVOIR WITH 4 GALLONS OF WATER TO COMPLETELY SUBMERSE THE PUNP. NOTE: DISTILLED WATER IS RECOMMENDED TO REDUCE MINERAL DEPOSITS AND BACTERIA BUILD-UP. RESERVOIR—| = '50232SL INSTRUCTIONS (PAGE 3/4) wove: SO0232SL ASSEMBLY_ INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS 14. INseRT SPOT LIGHT INTO SPOT LIGHT HOLDER, MAKE SURE THE LIGHT POWER CORD EXITS OUT FROM CHANNEL IN SPOT LIGHT HOLDER. THEN PLACE THE SPOT LIGHT HOLDER ONTO RESERVOIR TO COVER ENTRY. sor be vy spor uct BY rolne ~- ENTRY. RESERVOI 15. PLACE DECORATIVE RIVER STONES ONTO TOP OF THE RESERVOIR. 16. JoIN THE CONNECTORS AT TRANSFORMER AND SCREW THE CAP TIGHTLY TOGETHER. 17. PLUG TRANSFORMER AND POWER CORD INTO OUTLET, YOUR NEW FOUNTAIN IS READY FOR USE. DECORATIVE WER - SS RESERVOI Transrormer CONNECTOR) | (OA? TRANS1O16. (aepacement PART) /POHER CORD 9/10 TROUBLE SHOOTIN‘ 1. IF YOUR FOUNTAIN DOES NOT WORK, CHECK PLUG AT THE SOCKET. MAKE SURE THE PLUG IS FULLY AND PROPERLY INSERTED INTO THE WALL OUTLET. 2. NEXT CHECK TO MAKE SURE THE OUTLET IS POWERED. 3. IF THE FOUNTAIN STILL DOES NOT WORK, PLEASE CONTACT YOUR DISTRIBUTOR OR PLACE OF PURCHASE. SPLASHING DISCLAIMER: SPLASHING MAY OCCUR WHEN FOUNTAIN IS INITIALLY TURNED ON. PROTECT SURROUNDING SURFACES AS NEEDED. IMPORTANT PUMP INFORMATION: PUMP MUST BE FULLY SUBMERSED IN WATER WHILE OPERATING. WATER: TO REDUCE MINERAL DEPOSITS AND BACTERIA BUILD UP THE USE OF DISTILLED WATER IS RECOMMENDED. WARNING: * THIS FOUNTAIN IS RATED FOR INDOOR & OUTDOOR USE. ** ONCE A WEEK INSPECT FOUNTAIN, FLOOR AND ADJACENT WALL FOR MOISTURE BUILD-UP AND CLEAN AS NECESSARY. THIS IS ESPECIALLY IMPORTANT FOR HUMID ENVIRONMENTS. wes THIS UNIT MUST BE CONNECTED TO A SUPPLY CIRCUIT THAT IS PROTECTED BY A GROUND FAULT CIRCUIT INTERRUPTER (GFCI). THE GFCI SHOULD BE TESTED ON A ROUTINE BASIS. TO TEST THE GFCI, PUSH THE TEST BUTTON. THE GFCI SHOULD INTERRUPT POWER. PUSH THE RESET BUTTON. POWER SHOULD BE RESTORED. IF THE GFCI FAILS TO OPERATE IN THIS MANNER, THE GFCI IS DEFECTIVE. w#** THE FOUNTAIN IS FOR FLOOR USE ONLY, THE CHAIN IS FOR ADDED STABILITY. FOUNTAIN MUST MAINTAIN CONTACT WITH LEVEL FLOOR OPERATE PROPERLY. Vi PuMP2011_ (PUMP) TRANS1016_ (TRANSFORMER) 50232SL INSTRUCTIONS (PAGE 4/4)

You might also like