You are on page 1of 103

STANDARD SCHEDULE OF RATES

FOR

BUILDING WORKS

(JUL 2011)

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011)
CONTENTS S/N GENERAL PREAMBLES PARTICULAR PREAMBLES TO VARIOUS TRADES 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 EXCAVATION CONCRETE WORK BRICKWORK AND BLOCKWORK FLOOR FINISHES ROOFING CARPENTRY AND JOINERY IRONMONGERY STRUCTURAL STEELWORK & METALWORK WALL AND CEILING FINISHES SANITARY, WATER AND GAS INSTALLATION GLAZING PAINTING AND DECORATING TURFING, TREE PLANTING & LANDSCAPING WORKS MISCELLANEOUS DAYWORK DESCRIPTION PAGE 1-3 4 - 18 19 - 21 22 - 31 32 - 33 34 - 39 40 - 41 42 - 47 48 - 51 52 - 67 68 - 69 70 - 87 88 - 89 90 - 92 93 - 95 96 - 98 99 - 101

Published by Housing and Development Board, Republic of Singapore. No part of this document may be reproduced or copied in any form or by any means without the prior written permission of the publisher.

Page 1 of 101

GENERAL PREAMBLES
Introduction 1.1 The clauses in the General Preambles shall apply to all work items contained in the Standard Schedule of Rates. The Particular Preambles to each Trade shall be read in conjunction with the respective Trade in the Standard Schedule of Rates. All rates include the allowances for complying with the General and Particular Preambles. All rates contained in the Standard Schedule of Rates are fixed basic rates (in Singapore Currency) and no amendment whatsoever shall be made to such rates. The tenderers shall be deemed to have closely studied all rates contained herein and duly noted their implications. All rates contained in this Standard Schedule of Rates are exclusive of any Goods and Services Tax. Any such Goods and Services Tax shall be borne by the HDB as and when the same becomes due and payable. All work, materials and goods described in this Standard Schedule of Rates shall be of the respective kinds described in the Contract and in accordance with the instructions of the Superintending Officer or the Superintending Officer's Representative. Headings to groups of items shall be read as part of the descriptions of the items to which the headings apply. Where brand/trade names are given in the descriptions, they are solely intended for fixing the rates of the items. The products and materials to be used in the contract shall be governed by the specifications, Drawings and other documents forming the contract (and not this Schedule of Rates). Description of Works and Inclusions 7 Unless specifically stated otherwise, the following shall be deemed to be included in the description of the item of work:a) Labour and all costs in connection therewith including the labour in fabricating, assembling, setting, fitting and fixing of materials and goods in position.

1.2

1.3

Page 2 of 101

GENERAL PREAMBLES
Description of Works and Inclusions (Contd) b) Materials and goods including materials required for lapping, jointing and the like and all costs in connection therewith such as delivery, unloading, storing, returning of packings, handling, hoisting and lowering. Preparing surfaces to receive work. Protecting materials and work. Waste of materials. All cutting and waste. Use of construction equipment, tools, vehicles and all costs in connection therewith. Cleaning up on completion and making good all work disturbed. General requirements set out in the Specifications, Drawings and other documents forming the Contract. Establishment charges, overhead and profit.

c) d) e) f) g)

h) i)

j) 8

Unless otherwise stated, all work shall be measured net as fixed in its place. Where minimum deductions of voids are dealt with in this document they shall refer only to openings or voids which are within the boundaries of measured area. Openings or voids which are at the boundaries of measured area shall always be the subject of deductions irrespective of size. Billing of Quantities Where the unit of measurement is the linear metre, square metre and cubic metre, quantities shall be billed to the nearest whole unit. Fractions of the unit less than half shall be disregarded and all other fractions shall be regarded as a whole unit.

10.1

Page 3 of 101

GENERAL PREAMBLES
Billing of Quantities (Cont'd) 10.2 Where the unit of measurement is the kilogramme, quantities shall be billed to the nearest whole unit. Fractions of a unit less than half shall be disregarded and all other fractions shall be regarded as a whole unit. Where the unit of billing is the tonne or litre, quantities shall be billed to the nearest two places of decimals. Where the unit of measurement is the hour, fractions of the unit shall be billed to the nearest next half hour. Where the application of clauses 11.1 and 11.2 would cause an entire item to be eliminated, such item shall be billed to the nearest two places of decimals. Where rates with descriptions pertain to the same purpose are listed in more than one Standard Schedule of Rates incorporated in the Contract; the rate as listed in the following schedules (in the stated order of precedence) shall prevail:1st Precedence Standard Schedule of Rates for Building Works Standard Schedule of Rates for Civil Engineering Works Standard Schedule of Rates for Electrical Works

10.3

10.4

11

2nd Precedence

3rd Precedence

12

Unless otherwise stated, the term "as specified" means as specified in any of the documents forming part of the Contract. The following abbreviations are used for the units:m m2 m3 no kg ton pr sht ltr hr Linear metre Square metre Cubic metre Number Kilogram Tonne Pair Sheet Litre Hour

13

Page 4 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


1.0 EXCAVATION Definition of Ground Ordinary ground:- includes spoil or rubbish of every description, rubbish tip material etc, sand gravel, decomposed granite, red or white earth, loamy or gravelly clay, gravelly laterite, mud, bog or any other formation of pick and shovel and at any depth. Description The description of each item of excavation shall be deemed to include excavating around foundation, piles and confined areas, getting out, removing of bakau piles, trimming, levelling and compacting bottoms of excavations, keeping sides plumb and planking and strutting. Measurement The measurement of all excavations and subsequent disposal shall be those before excavating. The increases in bulk and any extra excavation required for earthwork support, planking and strutting and formwork for concrete shall be deemed to be included in the rates. No allowance for working space shall be made in the measurement of all excavation unless the method of construction requires workmen to operate from the outside of the structure. In such cases, a working space of 600mm shall be measured from the external face of the structure. Filling shall be measured as equal to the void to be filled. Any thickness stated shall be deemed to be after compacting. Rate Rates for each item shall be held to include for keeping all excavation free from water and site dry, pumping or bailing if required and providing any temporary drains required. Pre-Treatment of Soil against Subterranean Termites Measurement Soil treatment shall be measured flat on plan and the method of measurement shall be up to the perimeter of the building line (excluding the apron areas). Link buildings, linkways and other structures shall also be similarly measured. No deduction shall be made in the measurement for plan areas occupied by the column stumps.

1.1

1.2

1.3.1

1.3.2

1.3.3

1.3.4

1.4

1.4.1

1.4.2

Page 5 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


1.0 1.4.3 EXCAVATION (CONTD) The rates indicated shall be inclusive of the provision of warranty and shall not in any way affect the provisions of Building Specifications on Pre-Treatment of Soil for Protection of Buildings Against Subterranean Termites which provisions remain applicable in every respect in relation to all situations where these rates are applied. CONCRETE WORK Rate Rates for each item of concrete shall be held to include the following:a) Forming, cutting grooves, chases, mortices, holes and making good any other sundry items of a like nature. Extra labour for laying to falls, or cambers and preparing surfaces to receive screeds or pavings also to be included. All tests on concrete, cement and aggregate etc, as required and compliance with the strengths as specified. Tamping and/or vibrating to give thorough compaction; working between and around reinforcements. Laying on any type of sub-base; preparing and leaving surfaces to receive screeds or paving.

2.0

2.1

b)

c)

d)

e)

2.2

Deduction No deduction shall be made in the measurement of concrete work for:a) b) c) Voids of 0.05 cubic metre or less. Volume of the reinforcement and steelwork. Openings in walls, floor, roof slabs and the like of 0.10 square metre or less.

2.2.1

Measurement In the measurement of concrete for pile caps, the overall dimensions of the pile caps shall be taken. No deduction shall be made for the precast formwork panels.

Page 6 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


2.0 2.3 CONCRETE WORK (CONT'D) Reinforcement Description The description of each item of reinforcement shall be deemed to include:a) Allowances in the weight of reinforcement for rolling margins. b) All cleaning, cutting, bending, fabricating, placing, tying and the provision of all necessary distance blocks, tying wires, spacers or chairs, temporary fixings and supports.

2.3.1

2.3.2

Measurement The conversion factor for the various steel reinforcement bars shall be as follows: 6mm diameter 7mm diameter 8mm diameter 9mm diameter 10mm diameter 13mm diameter 16mm diameter 20mm diameter 22mm diameter 25mm diameter 28mm diameter 32mm diameter 0.222 kg/m 0.302 kg/m 0.394 kg/m 0.499 kg/m 0.616 kg/m 1.042 kg/m 1.579 kg/m 2.466 kg/m 2.984 kg/m 3.854 kg/m 4.834 kg/m 6.313 kg/m

2.4

Fabric Reinforcement Rate Rates for each item of fabric reinforcement shall be held to include for extra material at laps, tying wires and all bending, cutting and notching around obstruction. Only the net area covered shall be measured and no deduction shall be made for opening less than 1.00 square metre.

2.4.1

Page 7 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


2.0 2.5 CONCRETE WORK (CONT'D) Cage Reinforcement Rate Rates for each item of cage reinforcement shall be held to include for extra material at laps. Measurement The area of Beam Stirrup Cage Reinforcement shall be the product of the perimeter of stirrup multiplied by the length of the Cage. The area of the Capping Link shall be the product of the perimeter of the Link multiplied by the length of the Cage. The area for prefabricated pilecap mesh reinforcement shall be based on the bottom flat area of the mesh reinforcement without considering the upward projecting bars. The area for dowel mesh reinforcement shall be the product of the length and breadth which includes the depth of the bend. Formwork Description The description of each item of formwork shall be deemed to include:a) All necessary boardings, supports, erecting, framing, cutting, perforations for pipes, angles, cleaning, wetting and treatment with mould oil, mould liquid or limewhite and the like. All splayed edges, notchings, allowance for overlaps and passings at angles, battens, strutting, bolting, wedging, easing, striking and removal.

2.5.1

2.5.2

2.5.3

2.5.4

2.5.5

2.6

2.6.1

b)

2.6.2

Measurement Formwork shall be measured to the surface of work sloping more than 15 degree from the horizontal. Deduction No deduction shall be made in measurement of formwork for:a) b) c) Openings less than 1 square metre. Intersection of main and secondary beams. Intersection of beams and stanchion casing or columns.

2.6.3

Page 8 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


2.0 2.7 CONCRETE WORK (CONT'D) Unless otherwise stated, rates for concrete, reinforcement and formwork shall be applicable to all work irrespective of locality, positions, shapes and height. Precast Work Description a) All precast concrete components shall be grade 40 concrete as specified unless otherwise indicated. b) The description of each item of precast work shall be deemed to include concrete, reinforcement, formwork including the formation and filling of pockets, holes, chases and recesses for anchors, bolts and the like, grouting, pointing of joints, surface finishes, delivery, unloading, hoisting, erecting, fixing including all necessary temporary erection gear, bracing and working platforms.

2.8

2.8.1

2.9

Precast Concrete Vent Measurement The measurement of precast concrete vents shall be taken by volumes without deduction of voids. Piling Work Piling work shall be executed in accordance with the relevant Specifications and the instructions of Superintending Officer's Representative. Description The description of each type of piling work shall be deemed to include removal of underground obstructions together with all work in connection therewith unless specifically otherwise provided. The description of each type of piling work shall be deemed to include extending piles, dollying and connections unless specifically otherwise provided. Redriving or intermittent driving necessitated by lengthening or upheaving of piles or by the removal of obstructions under piles or other causes including moving and repositioning the piling frame shall be deemed to be included with the items of piling.

2.9.1

2.10 2.10.1

2.10.2

2.10.3

2.10.4

Page 9 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


2.0 2.10 CONCRETE WORK (CONT'D) Piling Work (Cont'd) Rate The rate of each item of piling shall be deemed to include:a) Handling, pitching, heading, pointing and bracing and providing protective wrought iron ring or helmet to pile. Cutting off surplus and heads of piles, preparing and integrating reinforcement into pile caps where applicable, extra excavation, backfilling and disposal of debris. Disposing of materials displaced arising out of driving the piles.

2.10.5

b)

c) 2.10.6

The rate of each item of treated timber piles includes the application of wood preservative to cut off surfaces of piles. The rate of each item of reinforced concrete piles includes moulds, reinforcement, preparing heads and extra labour and materials to receive pile extensions. The rate of each item of pile tests includes provision of all anchors, platforms, loading and unloading of materials, instruments and monitoring of the tests. Movement of piling frames into position and about the site, any necessary excavation or filling required to place the frames, raising or lowering the frames and any staging, barges or the like required to support the frames, shall be deemed to be included with the item of piling. Measurement Payment for treated timber piles driven shall be the product of the relevant rate per metre run and the penetration depth (measured from tip to cut-off level). The pay length of each reinforced concrete pile after it is driven into the ground is measured from the cut-off level of the pile to the end of pile shoe. Notwithstanding the provisions of Billing of Quantities contained in the General Preambles, the pay length of reinforced concrete piles shall be billed to the accuracy of nearest of 10mm.

2.10.7

2.10.8

2.10.9

2.10.10

2.10.11

Page 10 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


2.0 2.11 CONCRETE WORK (CONT'D) Surface Water Channels Rate Rates for each item of surface water channels shall be held to include for all angles, intersections, ends, outlets and extra labour and material for forming grooves or rebates to sides. Measurement Where an item is described as Add to last item for the increase in stages of 150mm deep, the difference of any depth less than 150mm shall be paid based on 150mm depth. BRICKWORK AND BLOCKWORK Rate The rates for each item of block, brickwork shall be held to include for all special made blocks, bricks and in-situ concrete in lieu, all rough and fair cuttings, oversailing and receding courses, rough relieving and discharging arches, wedging and pining, raking out joints for and pointing flashings, bedding plates, bedding and pointing of frames, parging and coring flues, labour eaves filling, plumbing angles, forming square and rebated reveals, cut squints or birdsmouths, notches, forming, leaving or cutting chases, holes and mortices, cutting and pining and making good and any other sundry items of a like nature. Rates for blockwork and brickwork shall be applicable to all work irrespective of positions, patterns, shapes and height. Deduction Deductions shall be measured the net sizes of the openings and recesses, including the extra width or rebated reveals. No deductions shall be made for openings of 0.50 square metre or less. Deductions shall be made for strings, sills, lintols and the like only when exceeding 100mm in height.

2.11.1

2.11.2

3.0

3.1

3.2

3.3

3.4

Page 11 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


4.0 FLOOR FINISHES Description The description of each item of floor finishes shall be deemed to include all temporary rules, temporary grounds, temporary screeds and the like, cutting holes, notching and the like, all normal bedding and pointing materials, providing all necessary samples, cleaning down and making good around pipes, sanitary fixtures and the like, work in narrow widths and small quantities in areas interrupted by seatings, channels and the like, all internal angles, quirks, grooves, throats, drips, coves and rounded external angles not exceeding 25mm radius, angles, stops, intersections, fair ends junctions, wreathed corners and the like on cornices, mouldings, enrichments, coves, skirtings, gutters, channels, strings, kerbs and similar or other sundry items of a like nature. The description of each item of floor finishes shall be deemed to include protecting surfaces from the weather or building operations. Rate Unless otherwise stated, rates in this section are applicable to works at horizontal surfaces exceeding 300mm wide. The rates for skirtings, shall be applicable to the following:(a) Drops, risers, sides of plinths and curbs and other vertical surfaces not exceeding 300mm high. Treads, top of curbs and other horizontal surfaces not exceeding 300mm wide.

4.1

4.2

4.3

4.4

(b)

4.5 4.6

Deduction No deduction shall be made for openings of 0.50 square metre or less. Measurement Where an item is described as Add to (or deduct from) ..... for each 5mm thickness over (or under) ......, the difference for any thickness less than 5mm shall be paid/deducted based on 5mm thick.

Page 12 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


5.0 ROOFING Description The description of each item of roofing shall be deemed to include:a) All laps, straight, skew and circular cutting at eaves, verges, top edges, abutments, valleys and hips, cutting holes for pipes, nails, screws, clips, pellets, straps and the like. Chasing the structure for burning-in or tucking in edges of coverings, flashing and the like. Holes in coverings, underbeds and insulations for pipes, standards and the like and making good.

5.1

b)

c)

5.2 5.3

Deduction No deduction shall be made for voids of 0.50 square metre or less. Membranes System and Panel Roofing System Rate Rates for Waterproofing Membranes System and Panel Roofing System shall be held to include for narrow widths, small quantities, temporary rules, covering up, protecting after laying and cleaning on completion, all labour to form arrises, fair edges etc., all cuttings and working around pipes, dress down at eaves to form drips or carried up at abutments to walls, pipes, parapets, skirtings, concrete curbs etc. and the like. Profiled Sheet Roofing Description The description of each item of profiled sheet roofing or cladding shall be deemed to include all cutting at square and raking abutments, top edges, bedding and pointing eaves fillers, verges, cutting and fitting and making good around outlets, pipes and any other sundry items of a like nature.

5.3.1

5.4

5.4.1

Page 13 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


6.0 CARPENTRY AND JOINERY Description The description of each item of carpentry work shall be deemed to include all cutting, notching, boring, sinking, pelleting, fitting, trimming, mitring, halving, morticing, tenoning, dovetailing, scarfing, wedging and all ends, splayed edges, short lengths and temporary supports and any other sundry of a like nature and also all labour in forming, drilling for bolts and fixing in position complete with nails, screws or adhesives. The description of each item of joinery work shall be deemed to include all nailing, gluing, screwing, plugging, cutting, notching, holes, housing ends, mitring ends and shaped ends, angles, junctions, heading joints, short lengths, tongued angles, splayed or rounded edges, chamfers, rebates, grooves and any other sundry items of a like nature including stops and working cross-grain, fitting and hanging and the like. Nominal sizes are stated for wrot timber and an allowance of 2.5mm is permitted for each wrot face. Rates for windows and doors include hanging and fixing. Where ironmongery is included in the description of doors, it shall be deemed to include hinges, floor springs, door gears, locks, latches, catches, bolts, closers, holders, padlocks, stoppers, push-bars and plates, pull bars and handles, kickplates, locking eyes and the like as specified. IRONMONGERY Rate Rates for each item shall be held to include for supply, delivery to site and fixing complete with all matching screws of the same finish as ironmongery, nails, pins or brads, cutting sinking and boring and morticing as required, oiling and easing and adjusting all moving parts, taking off and refixing after painting where necessary and handing 3 keys properly labelled to the Superintending Officer or the Superintending Officer's Representative etc unless otherwise described.

6.1

6.2

6.3

6.4 6.5

7.0

7.1

Page 14 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


8.0 8.1 STRUCTURAL STEELWORK AND METALWORK Description The description of each item of work shall be deemed to include:a) b) Allowances for rolling margins and the weight of welding materials. Shop and site fabrication including drilling, cutting (including holes and openings for other trades), notching, splicing, mitring, welding, riveting, bolting, machining ends and bearings, delivery, unloading, handling, assembling, hoisting, erecting, fitting and fixing in position, bedding, filling in solid, polishing and pointing including necessary lugs or other attachment. Provision of all necessary construction equipment, temporary bracing supports and the like required for erection, providing samples and tests required by the specification, the inspection of welds including the use of any special radio-graphic techniques. Protection such as wrapping finished work with paper, coating with grease or carrying out such other protective measures as may be required and removing and cleaning on completion. Nuts and any type of washer which may be required. Preparation of shop Drawings.

c)

d)

e) f)

8.2

Deduction No deduction shall be made for drillings, holes, notchings, splay cuts and the like. Measurement Weights stated shall be net theoretical weights. Steel sections and plates in connections or fitted stiffeners, column cap and base plates, rigid frame bases and butt plates, purlins, girts, eaves, fascias and similar cleats or brackets attached to trusses, lattice girders and open web joists and plates, and similar items shall be weighted at net dimensions. Irregular, including circular shaped plates shall be weighted at the smallest size rectangles from which they can be cut; regular and triangular shaped plates shall be weighted at net dimensions.

8.3 8.4

8.5

Page 15 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


8.0 8.6 STRUCTURAL STEELWORK AND METALWORK (CONTD) Half or other parts of steel sections in connections shall be weighted at half the weight of the section from which they have been cut when equal to or less than half the section and at the full weight of the section from which they have been cut when greater than half the section.

9.0

WALL AND CEILING FINISHES Rate Rates for each item shall be deemed to include the provision of keys to receive finishes, all temporary rules, temporary grounds, temporary screeds and the like, cramps, dowels, ties, special metal supporting brackets and the like, cutting holes, notching and the like, masking, labour to internal angles other than coved angles, making good around pipes, sanitary fixtures and the like, work in narrow widths and small quantities, joints between different types of work, joints between new and old work, internal angles, fair edges, rounded or chamfered edges or angles, quirks, grooves, V-joints, groin points and other intersections of curved surfaces, rounded coves and external angles not exceeding 25mm radius, necessary UPVC trimming pieces, mitres, stops and the like on cornices, mouldings, architraves, coves, skirtings, gutters, strings and all making good and any other sundry items of a like nature. Rates for each item shall also be deemed to include protecting surfaces from the weather or building operations. Rates for each item of wall tiling shall be held to include for narrow widths and small quantities, fittings around air bricks, pipes and the like and any other sundry items. Rates for each item of terrazzo shall be held to include for narrow widths and small quantities, and for all temporary rules, internal angles, arises, joints between different types of terrazzo, quirks and all making good and any other sundry items of a like nature on in-situ terrazzo, fitting around air bricks, pipes and the like and any other sundry items of a like nature on precast terrazzo. Deduction No deduction shall be made for openings of 0.50 square metre or less. Measurement In the measurement of plastering, no deduction shall be made for casings for pipes under 300mm wide or angles which are finished in a different material if these do not exceed 100mm girth.

9.1

9.2

9.3

9.4

9.5

9.6

Page 16 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


9.0 9.7 9.8 WALL AND CEILING FINISHES (CONTD) Measurement of ceilings shall include sides and soffits of beams. "Within the building" shall mean surfaces within the internal of buildings/flats, corridors, staircases and the like which normally do not entail scaffolding or mechanical cradles to carry out the works. "External face of building" shall mean surfaces such as gable end walls, front/back external walls and any other surfaces which are constantly exposed to weather and/or which normally require the use of scaffolding or mechanical cradles to carry out the work. Work shall be deemed to be executed when scaffolding has been provided during the course of construction. Should scaffolding be required separately just to execute the work, it would be paid as an extra item.

9.9

9.10

10.0

SANITARY, WATER AND GAS INSTALLATION Description The description of each item of pipework shall be deemed to include:a) All short lengths, joints in the running lengths, joints to all branches, tees, sockets, sleeves, connectors, backnuts, nipples, standard pipe framings or supporting clips, saddles, fastening brackets, holderbats, straps and the like. b) c) Giving notices. Complying with all requirements of the relevant authorities, paying fees and the like in connection with the installations and preparing and submitting Drawings for approval if required.

10.1

10.2

Measurement Where an item is described as Add to last item for each additional 150mm depth, the difference of any depth less than 150mm shall be paid based on 150mm depth.

11.0

GLAZING Rate Rates for each item of glazier shall be held to include for cutting and rounded edges, fixing panel pins, clips, brass screws and cup, neoprene strips, silicone sealants and the like and leaving the glass clean on completion

11.1

Page 17 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


12.0 PAINTING AND DECORATING Rate Rates for each item of painting shall be held to include for all necessary preparation of surfaces including cleaning off, knotting, stopping and sandpapering woodwork, wirebrushing metal and leaving all surfaces free from dust, rust, grease and oil before painting, narrow widths, etc. All items in this section shall be deemed to include for multi-coloured works. Deduction No deduction shall be made for openings of 0.50 m2 or less. Work shall be deemed to be executed when scaffolding has been provided during the course of construction. Should scaffolding be required separately just to execute the work, it would be paid as an extra item.

12.1

12.2

12.3 12.4

13.0

TURFING AND TREE-PLANTING & LANDSCAPING WORKS Definition of Approved Soil Mixture Approved soil mixture shall be three parts topsoil with one part of soil conditioner and 1 kg per m3 of granular fertilizer NPK (15:15:6.4) or 4:2:1 subsoil, unwashed sand and soil conditioner with 1 kg per m3 of granular fertilizer NPK (15:15:6.4). Measurement The measurement of girths of the trees shall be at a height of 1.0 metre above ground. Rates The rate for cutting down trees shall be deemed to include for grubbing up roots and filling of voids after removal of tree roots. The rate of each item of turfing and planting shall be deemed to include for watering, weeding, fertilizing, cutting, settlement, re-seeding and maintenance during the Maintenance Period as specified.

13.1

13.2

13.3

13.4

Page 18 of 101

PARTICULAR PREAMBLES TO VARIOUS TRADES


14.0 DAYWORK Rate Rates shall be applicable in respect of all work executed on a daywork basis. During the continuance of such work, the Contractor shall keep proper records of the names, occupations and working hours of all workmen employed for such work and the quantities and descriptions of all materials and construction equipment employed. Such records, receipts or vouchers must be verified by the Superintending Officer or the Superintending Officer's Representative before payment can be effected.

14.1

Page 19 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) EXCAVATION Excavation oversite commencing from ground level in ordinary ground, including forming of surfaces and removal of surplus excavated materials within site, for the following average overall depth:

CODE

1 2 3 4

not exceeding 150mm deep. exceeding 150mm but not exceeding 300mm deep. exceeding 300mm deep. Excavation in Embankment commencing from reduced level in ordinary ground including forming of surfaces and removal of surplus excavated materials within site. Excavate to form Trenches for Columns, Pilecaps, Foundations, Beams, Basements, Pier Holes etc in ordinary ground including forming of bottom, necessary planking and strutting, part return, fill and ram, and remainder get out and deposit on site as directed in stages of the following depth:

m m m m

2.00 3.60 10.90 12.50

SA001 SA002 SA003 SA007

5 6 7 8

not exceeding 2.00m deep. exceeding 2.00m but not exceeding 4.00m deep. exceeding 4.00m but not exceeding 6.00m deep. exceeding 6.00m but not exceeding 8.00m deep. Excavation for HARD GROUND where blasting will not be permitted HARD GROUND is defined as: cemented sand, shale, decomposed rock or other material with Standard Penetration Values not exceeding 70 blows per 30cm and bulk density not exceeding 2100kg/m3 and can be excavated by heavy machinery with a maximum breakout force of 13,000kg such as Caterpillar 977L or its equivalent:

m m m m

21.30 23.10 26.20 29.40

SA008 SA009 SA010 SA042

9 10 11

not exceeding 2.00m deep. exceeding 2.00m but not exceeding 4.00m deep. exceeding 4.00m but not exceeding 6.00m deep.

m m m

32.50 37.00 43.40

SA012 SA013 SA014

Page 20 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) EXCAVATION (CONT'D) Excavate to form trenches for drain lines in ordinary ground including forming of bottom, necessary planking and strutting, get out and deposit on site as directed and backfill excavated trench with granite dust/fines in stages of the following depth:

CODE

12 13

not exceeding 2.00m deep. exceeding 2.00m but not exceeding 4.00m deep. Excavate to form trenches for service pipes, cable crossings, etc. in ordinary ground including forming bottom and get out, deposit on site as directed and backfill trench in stages of the following depths:

m m

43.10 44.20

SA034 SA035

14 15

not exceeding 2.00m deep with granular materials. exceeding 2.00m but not exceeding 4.00m deep with ditto. not exceeding 2.00m deep with selected excavated material. exceeding 2.00m but not exceeding 4.00m deep with ditto. not exceeding 2.00m deep with selected imported earth. exceeding 2.00m but not exceeding 4.00m deep with ditto. CART AWAY excavated materials off site and deposit at the Contractor's own dumping ground. Dry approved earth filling obtained from outside source and fill in layers of 300mm thick; including labour for spreading, trimming and consolidating to form earth mounds or to form levels outside buildings and/or under floor slabs, etc as specified. Selected excavated material obtained within the site and used as filling to make up level including consolidation.

m m

39.80 40.00

SA038 SA039

16

15.80

SA036

17

16.00

SA040

18

24.90

SA037

19

25.10

SA041

20

10.80

SA016

21

14.70

SA017

22

13.90

SA018

Page 21 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) EXCAVATION (CONT'D)

CODE

23

80mm diameter (minimum) bakau piles as roller supports.

1.70

SA033

24

Unwashed sand including spreading, levelling and consolidating. Hardcore in beds, comprising of clean broken bricks/concrete, deposit, spread, levelled, mechanically consolidated and including 25mm thick sand or granite dust blinding/topping. Granite dust, spread, level and consolidate. Pre-treatment of soil for the protection of building against subterranean termites with approved chemicals including a layer of black polythene sheets on top of the treated area (treated/untreated area shall be measured flat on plan up to the perimeter of the building line excluding apron areas - rate inclusive of the provision of a 5-year warranty). Supply and delivery of Grade 43 steel sheet piles for use as temporary shoring to retain the sides of excavation in approved section and lengths. Driving Grade 43 steel sheet piles including the provision of all labour, Construction equipment (providing, assembling and subsequent dismantling of piling equipment measured separately), tools and everything necessary for the installation as specified. Extracting, recovering and stacking Grade 43 steel sheet piles including the provision of all labour, tools (providing, assembling and subsequent dismantling of piling equipment measured separately), and everything necessary for the execution as specified. Grade 43 steel sheet piles left in permanently including the provision of all labours, tools (providing, assembling and subsequent dismantling of piling equipment measured separately), and everything necessary for the installation as specified. Providing and assembling of necessary piling equipment to drive/extract Grade 43 steel sheet piles of any size including all necessary tools and appliances, subsequent dismantling and removal on completion of the work on site.

50.70

SA020

25

24.20

SA024

26 27

m m

53.20 12.50

SA025 SA027

28

ton

171.30

SA028

29

ton

379.50

SA029

30

ton

253.00

SA030

31

ton

1,847.50

SA031

32

item

8,159.30

SA032

Page 22 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK Mass/lean concrete to underside of foundations, ground beams, floor slabs, apron slabs, etc irrespective of thickness as specified:

CODE

33 34

Concrete (1:3:6). Concrete (1:2:4). Reinforced Concrete in foundations, ground beams, column stumps, ground floor slabs, apron slabs etc including working around rod or fabric reinforcement below ground floor level as specified (reinforcement measured separately):

m m

116.30 118.70

SB003 SB002

35 36 37 38 39 40 41 42

Grade 20. Grade 25. Grade 30. Grade 35. Grade 40. Grade 45. Grade 50. Extra over grade 40 reinforced concrete for the provision of precast pilecap formwork panels including fabrication and all necessary tie bars and clamps. Reinforced Concrete to suspended slabs, beams, columns, staircases, walls, etc including working around rod or fabric reinforcement above ground floor level as specified (reinforcement measured separately):

m m m m m m m m
2

122.20 124.60 127.00 129.50 133.10 134.90 140.90 46.10

SB004 SB006 SB008 SB111 SB113 SB116 SB118 SB367

43 44 45 46

Grade 20. Grade 25. Grade 30. Grade 35.

m m m m

129.10 131.60 134.00 136.40

SB005 SB007 SB009 SB112

Page 23 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Reinforced Concrete to suspended slabs, beams, columns, staircases, walls, etc including working around rod or fabric reinforcement above ground floor level as specified (reinforcement measured separately) (Cont'd):

CODE

47 48 49 50

Grade 40. Grade 45. Grade 50. Approved damp proof membrane Type B (felt fibre base) to underside of reinforced concrete slab including provision for laps and preparation of surface as specified.

m m m m

140.00 141.80 147.90 9.30

SB114 SB117 SB119 SB011

51

Liquid-applied flexible cementitious or water-based Waterproofing Membrane to bath/wc/kitchen floors including upturns on pipes and walls as specified (Measured flat-on-plan and no adjustment to be made for voids occupied by pipes). Mild Steel Rod Reinforcement, fabricated and laid in foundations, beds, suspended slab, walls, columns, beams, staircases etc, and including labour for forming stirrups, links etc:

12.50

SB359

52 53 54 55 56 57 58

6mm diameter. 8mm diameter. 10mm diameter. 13mm diameter. 16mm diameter. 20mm diameter. 25mm diameter.

kg kg kg kg kg kg kg

2.40 2.20 2.00 2.00 2.00 1.80 1.70

SB022 SB154 SB023 SB024 SB025 SB026 SB028

Page 24 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Deformed High Tensile Steel Rod Reinforcement, fabricated and laid in foundations, beds, suspended slabs, walls, columns, beams, staircases etc, and including labour for forming stirrups, links etc:

CODE

59 60 61 62 63 64 65 66 67 68 69

6mm diameter. 8mm diameter. 10mm diameter. 13mm diameter. 16mm diameter. 20mm diameter. 22mm diameter. 25mm diameter. 28mm diameter. 32mm diameter. Extra over steel rod reinforcement for galvanising. Welded steel fabric reinforcement well lapped and tied at joints (measured nett) :

kg kg kg kg kg kg kg kg kg kg kg

2.40 1.90 2.00 2.00 1.90 1.80 1.80 1.80 1.80 1.80 0.80

SB155 SB157 SB031 SB032 SB033 SB034 SB035 SB036 SB037 SB038 SB039

70 71 72 73

A5. A6. A7. A8.

m m m m

3.70 4.70 6.00 7.50

SB040 SB041 SB042 SB043

Page 25 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Welded steel fabric reinforcement well lapped and tied at joints (measured nett) (Cont'd):

CODE

74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94

A10. A12. B5. B6. B7. B8. B8A. B9. B10. B12. B13. D5. D6. D7. D8. D9. D10. D11. D12. D13. Dowel Mesh (DM).

m m m m m m m m m m m m m m m m m m m m m

11.40 16.00 6.50 7.50 8.40 11.00 6.50 12.90 14.80 18.90 24.30 6.70 8.70 11.20 14.40 18.00 22.20 26.60 30.80 36.20 8.90

SB145 SB284 SB146 SB147 SB148 SB149 SB352 SB229 SB150 SB151 SB350 SB346 SB048 SB049 SB124 SB230 SB231 SB347 SB348 SB349 SB358

Page 26 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Prefabricated pilecap mesh reinforcement:

CODE

95 96 97 98 99 100 101 102 103 104 105 106 107

Type H1320 0840. Type H1315 1315. Type H1310 1310. Type H1310 1610. Type 2H1310 1320. Type 2H1315 1315. Type 2H1310 0840. Type 2H1315 0840. Type 2H1310 1310. Type 2H1310 1610. ECC mesh H1320 (Type 1) ECC mesh H1320 (Type 2) Prefabricated pilecap link mesh reinforcement. Prefabricated beam stirrup cage reinforcement:

m m m m m m m m m m m m m

13.10 25.10 34.90 45.00 44.80 36.40 38.00 26.70 53.20 61.90 12.10 13.30 19.90

SB326 SB354 SB324 SB325 SB327 SB331 SB330 SB355 SB328 SB329 SB363 SB364 SB332

108 109 110 111 112 113 114 115 116

Reference no. S07. Reference no. S10. Reference no. S15. Reference no. S20. Reference no. S25. Reference no. S130. Reference no. S137. Reference no. 2S130 (twin). Prefabricated beam capping link reinforcement no R10300.

m m m m m m m m m

17.50 14.20 11.00 9.30 8.40 21.00 26.50 36.40 19.10

SB280 SB167 SB168 SB169 SB170 SB281 SB333 SB334 SB288

Page 27 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Prefabricated wall mesh reinforcement:

CODE

117 118

Type H1320 0820. Type H1310 0820. Prefabricated column link cage of R6 reinforcement (Reference no L36, L36A, L36B, L46, L46A, L46B, L56, L56A, L56B) :

m m

11.70 20.90

SB356 SB357

119 120 121 122

at 100mm spacing. at 150mm spacing. at 175mm spacing. at 200mm spacing. Prefabricated column link cage of R8 reinforcement (Reference no L38, L38A, L38B, L48, L48A, L48B, L58, L58A, L58B) :

m m m m

7.60 6.40 6.00 5.80

SB306 SB307 SB337 SB308

123 124 125 126 127

at 100mm spacing. at 150mm spacing. at 200mm spacing. at 250mm spacing. Timber formwork to surfaces of concrete foundations, column stumps, ground beams, ground floor slabs, etc. Timber formwork to surfaces of concrete columns, walls, suspended slabs, stairs, canopies, beams, lintols etc. Timber formwork to produce a good off-form finish to surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols etc. as specified. Formwork of approved materials to produce a good offform finish to curved surfaces of concrete columns, walls, slabs, beams, staircases, canopies, lintols, etc. as specified. LABOUR ONLY for preparing, cleaning, assembling, erecting and dismantling of metal formwork of any types to surfaces of concrete columns, walls, suspended slabs, staircases, canopies, beams etc.

m m m m m

10.50 8.30 7.20 6.50 16.00

SB309 SB310 SB311 SB338 SB110

128

24.00

SB062

129

32.70

SB274

130

40.50

SB275

131

27.60

SB064

Page 28 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) PRECAST CONCRETE in sills, lintols, slabs, etc including moulds, hoisting and fixing in position:

CODE

132 133 134 135 136 137 138

Grade 25 with reinforcement. Grade 25 without reinforcement. Grade 30 with reinforcement. Grade 30 without reinforcement. Grade 40 with reinforcement. Grade 40 without reinforcement. Precast concrete Grade 40 in footing/stump including moulds, hoisting and placing in position (reinforcement measured separately). Hacking through reinforced concrete floors or walls (any thickness) to form opening including making good and remove debris from site. Breaking up existing reinforced concrete structures including removing debris off the site. Breaking up of existing mass concrete structures including removing debris off the site. One layer of approved epoxy concrete bonding agent to hacked concrete surfaces before concreting. Concrete in small quantities not exceeding 0.15m including all necessary formwork:

m m m m m m m

509.00 268.20 511.50 270.60 517.50 276.70 249.00

SB158 SB159 SB161 SB162 SB339 SB340 SB380

139

645.30

SB068

140

128.20

SB164

141

101.60

SB165

142

26.20

SB166

143 144 145 146

Grade 20. Grade 25. Grade 30. Grade 40.

m m m m

327.40 331.00 334.60 343.70

SB069 SB160 SB163 SB317

Page 29 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Coring of holes through concrete structure including removal of debris off site:

CODE

147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169

25 to 31mm diameter x 100 to 200mm depth. 25 to 31mm diameter x 201 to 300mm depth. 25 to 31mm to diameter x 301 to 400mm depth. 32 to 49mm diameter x 100 to 200mm depth. 32 to 49mm diameter x 201 to 300mm depth. 32 t0 49mm diameter x 301 to 400mm depth. 50 to 74mm diameter x 100 to 200mm depth. 50 to 74mm diameter x 201 to 300mm depth. 50 to 74mm diameter x 301 to 400mm depth. 75 to 99mm diameter x 100 to 200mm depth. 75 to 99mm diameter x 201 to 300mm depth. 75 to 99mm diameter x 301 to 400mm depth. 100 to 149mm diameter x 100 to 200mm depth. 100 to 149mm diameter x 201 to 300mm depth. 100 to 149mm diameter x 301 to 400mm depth. 150 to 199mm diameter x 201 to 300mm depth. 150 to 199mm diameter x 301 to 400mm depth. 200 to 249mm diameter x 100 to 200mm depth. 200 to 249mm diameter x 201 to 300mm depth. 200 to 249mm diameter x 301 to 400mm depth. 250 to 299mm diameter x 100 to 200mm depth. 250 to 299mm diameter x 201 to 300mm depth. 250 to 299mm diameter x 301 to 400mm depth.

no no no no no no no no no no no no no no no no no no no no no no no

50.50 62.30 74.70 47.70 50.60 74.70 62.10 77.10 92.90 71.00 86.80 105.50 79.90 104.90 124.50 149.50 179.10 145.20 174.80 217.60 143.20 191.50 264.50

SB190 SB193 SB194 SB300 SB301 SB302 SB195 SB198 SB199 SB200 SB203 SB204 SB205 SB208 SB209 SB213 SB214 SB215 SB218 SB219 SB319 SB320 SB321

Page 30 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D) Coring of holes through concrete structure including removal of debris off site (Cont'd):

CODE

170 171 172

300mm diameter x 100 to 200mm depth. 300mm diameter x 201 to 300mm depth. 300mm diameter x 301 to 400mm depth. Forming bituminous expansion joint in concrete floors including all necessary formwork and bituminous seal:

no no no

192.30 225.00 264.50

SB220 SB223 SB224

173 174 175

13mm wide x 75mm deep. 25mm wide x 100mm deep. Forming of 25mm wide expansion joint in cavity with foam plastic infill as specified. Forming of surface channel 150mm wide x 50mm deep on concrete floor slab to fall. 225mm wide (internal) Reinforced Concrete SURFACE DRAIN constructed with 100mm thick sides, 100mm thick bottom and all exposed sides, bottom and arrises rendered smooth in cement mortar including all necessary excavation, formwork and lean concrete laid to fall as directed:

m m m

6.30 14.40 2.40

SB316 SB096 SB120

176

1.90

SB360

177

Grade 25 not exceeding 400mm deep (average) to invert and reinforced with B6 WSF reinforcement. Add to LAST ITEM for the increase in stages of 100mm deep. Grade 40 not exceeding 400mm deep (average) to invert and reinforced with A7 WSF reinforcement. Add to LAST ITEM for the increase in stages of 100mm deep. Extra over 225mm wide reinforced concrete drain for PRECAST CONCRETE INVERT.

91.50

SB099

178

17.70

SB100

179

90.80

SB314

180

17.60

SB315

181

2.90

SB105

Page 31 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CONCRETE WORK (CONT'D)

CODE

182

225mm wide (internal) grade 40 precast concrete house drain not exceeding 400mm deep (average) to invert with 100mm thick sides and bottom complete with reinforcement and topping up sides with in-situ concrete including all necessary jointing, excavation, formwork and lean concrete and laid to falls as specified.

63.20

SB365

183

Add to LAST ITEM for the increase in stages of 100mm deep. 315mm diameter UPVC pipe conforming to SS272 for concealed drain outlet with Grade 30 concrete bed and reinforced with WSF B5 including formwork and lean concrete (excavation measured separately) Precast concrete (Grade 40) components including all reinforcement, moulds, formwork stacking, hoisting, setting, labour and materials for jointing, testing accessories and protection, etc as specified:

5.00

SB366

184

83.10

SB371

185 186 187 188 189

100mm normal weight Partition Wall 90mm normal weight Partition Wall 70-90mm thick Prestressed Plank 70-90mm thick Non-prestressed Plank 75mm thick Ferrolite Partition Wall (design mix as specified) 250mm Gable End Wall Faade Wall without Beam Beam Precast concrete (Grade 50) components including all reinforcement, moulds, formwork stacking, hoisting, setting, labour and materials for jointing, testing accessories and protection, etc as specified:

m m m m m

88.00 82.20 67.60 84.80 63.80

SB130 SB131 SB381 SB383 SB384

190 191 192

m m m
3

198.40 75.90 580.80

SB134 SB132 SB372

193

Column/300mm thick Wall

592.30

SB373

Page 32 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) BRICKWORK AND BLOCKWORK Brickwork in standard common bricks (size 215 x 102.5 x 65mm) laid in prepacked mortar as specified with 10mm joints raked 10mm deep or flush pointed as work proceeds:

CODE

194 195 196

Generally. One brick thick wall. Half brick thick wall reinforced with expanded metal brickwork reinforcement. Half brick thick wall built honeycomb. Common brickwall using modular bricks laid in prepacked mortar as specified with 10mm joints raked 10mm deep or flush pointed as the work proceeds:

m m m

293.40 69.60 35.40

SC005 SC006 SC007

197

27.10

SC008

198

90mm thick reinforced with expanded metal brickwork reinforcement. 190mm thick. 290mm thick. Red facing brickwall using modular bricks laid in prepacked mortar as specified with 10mm joints raked 10mm deep or flush pointed as the work proceeds:

30.10

SC016

199 200

m m

59.70 83.30

SC015 SC044

201

90mm thick reinforced with expanded metal brickwork reinforcement. 190mm thick. Extra over common modular brickwork for using red facing bricks to one face of the brickwall (applicable to brickwall of thickness 190mm and above).

60.70

SC055

202 203

m m

117.40 34.40

SC062 SC017

Page 33 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) BRICKWORK AND BLOCKWORK (CONT'D) Glass block wall laid in premix mortar complete with panel reinforcing, panel anchors, expansion strips, etc as specified:

CODE

204

146 x 146 x 98mm thick "Pittsburgh Corning" transparent/non-transparent glass blocks. Extra over item SC047 for using colour coated edge blocks. 197 x 197 x 98mm thick "Pittsburgh Corning" transparent/non-transparent glass blocks. Extra over item SC045 for using colour coated edge blocks. 145 x 145 x 95mm thick "NEG" transparent/nontransparent glass blocks. 190 x 190 x 95mm thick "NEG" transparent/nontransparent glass blocks. Solid block wall laid in prepacked mortar as specified:

439.90

SC047

205

41.60

SC048

206

294.70

SC045

207

23.40

SC046

208

434.00

SC052

209

311.70

SC049

210

70mm thick wall using 190 x 90 x 70mm solid blocks.

27.60

SC027

211

90mm thick wall using 190/290 x 90 x 90mm solid blocks. 190mm thick wall using 190 x 90 x 90mm solid blocks. Breaking up blockwork or brickwork in cement mortar including plaster (measured in gross thickness) and removing debris off site. Approved horizontal damp proof course Type B (felt fibre base) to brick/block walls bedded in prepacked mortar as specified. 13mm deep polyurethane sealant joint (horizontal or vertical) with 10mm diameter backer rod to gap between brickwall and beam/column as specified.

31.10

SC028

212

61.20

SC030

213

40.10

SC031

214

14.50

SC035

215

6.40

SC040

Page 34 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) FLOOR FINISHES

CODE

216

Hack existing concrete surface to form keys and wash clean to receive finishing. Extra over concrete slab for trowelling surface of floor or roof slab. Extra over concrete slab for compacting and trowelling smooth surface of reinforced concrete floor slab by power trowel. Extra over concrete floor or screed for the application of approved non-metallic hardener with power trowelled finish including spraying a coat of approved curing agent onto the finished surface as specified. Extra over concrete ramp for the application of approved non-metallic hardener with power trowelled finish including spraying a coat of approved curing agent onto the finished surface and forming ring indentations as specified (measured flat on plan). Forming 10mm wide groove lines on surfaces of concrete ramp:

2.60

SD001

217

0.80

SD002

218

2.30

SD003

219

14.90

SD082

220

19.90

SD083

221 222

At not more than 150mm apart. Exceeding 150mm but not more than 300mm apart.

m m

5.60 2.50

SD104 SD109

223

Matt finished polymer surface coating of approved colours over roof slab as specified. (rate inclusive of the provision of a 5-year warranty). 20-30mm thick non-shrink cement rendering to concrete surfaces trowelled to a smooth finish. 10mm thick prepacked waterproof screed for kitchen, bath and WC floors as specified. ADD to (or deduct from) ITEM SD110 for each 5mm thickness over (or under) 10mm. 20mm thick prepacked screed to floor trowelled to a smooth finish. ADD to (or deduct from) ITEM SD004 for each 5mm thickness over (or under) 20mm.

31.10

SD103

224

91.10

SD105

225

6.80

SD110

226

2.00

SD112

227

8.50

SD004

228

1.70

SD005

Page 35 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) FLOOR FINISHES (CONT'D) 20mm thick prepacked screed to skirting, treads, risers, curbs and returns etc and trowelled to a smooth finish including coved and rounded angles:

CODE

229 230

Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width. ADD to (or deduct from) ITEM SD006 for each 5mm thickness over (or under) 20mm. ADD to (or deduct from) ITEM SD007 for each 5mm thickness over (or under) 20mm. 20mm thick prepacked screed to receive floor finishes. ADD to (or deduct from) ITEM SD087 for each 5mm thickness over (or under) 20mm. 25mm thick Concrete Screed (Grade 25) with 10mm maximum size aggregate to concrete floor surfaces finished with steel trowelling including all necessary labour and materials for preparation of substrate's surface to receive screed as specified. ADD to (or deduct from) ITEM SD010 for each 5mm thickness over (or under) 25mm. 25mm thick Concrete Screed (Grade 25) with 10mm maximum size aggregate to skirting, treads, risers, curbs and return etc, trowelled to a smooth finish including coved and rounded angles and all necessary labour and materials for preparation of substrate's surface as specified:

m m

5.10 7.90

SD006 SD007

231

1.00

SD008

232

1.60

SD009

233 234

m m

6.90 1.40

SD087 SD088

235

8.90

SD010

236

1.40

SD011

237 238

Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width. ADD to (or deduct from) ITEM SD012 for each 5mm thickness over (or under) 25mm . ADD to (or deduct from) ITEM SD013 for each 5mm thickness over (or under) 25mm.

m m

6.40 9.20

SD012 SD013

239

1.00

SD014

240

1.50

SD015

Page 36 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) FLOOR FINISHES (CONT'D)

CODE

241

20mm thick granolithic paving consisting of cement, sand and granite chippings (1:1:2) to floor and trowelled to a smooth finish. ADD to (or deduct from) ITEM SD019 for each 5mm thickness of granolithic layer over (or under) 20mm. 20mm thick granolithic consisting of cement, sand and granite chippings (1:1:2) to skirtings, treads, risers, curbs and returns etc and trowelled to a smooth surface including coved and rounded angles:

10.00

SD019

242

2.00

SD020

243 244

Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width. ADD to (or deduct from) ITEM SD021 for each 5mm thickness over (or under) 20mm. ADD to (or deduct from) ITEM SD022 for each 5mm thickness over (or under) 20mm. Extra over granolithic paving (irrespective of thickness) for exposed aggregate finish. Extra over granolithic paving (irrespective of thickness) for exposed aggregate finish all as in ITEM SD025 but for skirting etc not exceeding 150mm in height/width. Extra over granolithic paving (irrespective of thickness) for exposed aggregate finish all as in ITEM SD025 but for skirting etc exceeding 150mm but not exceeding 300mm in height/width. 50mm thick cement rendering to floor slab including 20mm thk granolithic paving consisting of cement, sand and granite chippings (1:1:1) with concrete hardener trowelled to a smooth finish.

m m

5.90 7.90

SD021 SD022

245

1.10

SD023

246

1.60

SD024

247

7.80

SD025

248

2.10

SD026

249

3.50

SD027

250

26.30

SD116

Page 37 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) FLOOR FINISHES (CONT'D) 8mm thick quarry tiles laid and bedded on and including necessary prepacked base screed as specified:

CODE

251 252 253

100 x 100mm tiles. 200 x 100mm tiles. Brick-on-edge paving using red facing modular bricks laid to approved pattern, jointed and pointed in prepacked mortar as specified (screed measured separately).

m m m

42.70 40.60 59.00

SD043 SD044 SD047

254

190mm wide brick-on-edge curb using M211 red facing modular bricks jointed and pointed in prepacked mortar as specified (screed measured separately). 190mm wide brick-on-edge curb/coping using M211 red facing bullnose/splayed edge bricks jointed and pointed in prepacked mortar as specified (screed measured separately) Grade C glazed ceramic floor tiles of approved colours, patterns and textures (nominal size 200 x 200 x 8mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Grade C glazed ceramic floor tiles of approved colours, patterns and textures (to match 200 x 200 x 8mm thick tiling) to skirtings, treads, risers, curbs, nosing and returns, bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified:

17.50

SD054

255

17.60

SD070

256

43.00

SD092

257 258

Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width.

m m

10.10 16.30

SD093 SD094

Page 38 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) FLOOR FINISHES (CONT'D)

CODE

259

Grade C glazed ceramic floor tiles of approved colours, patterns and textures (nominal size 300 x 300 x 9mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified.

45.40

SD064

Grade C glazed ceramic floor tiles of approved colours, patterns and textures (to match 300 x 300 x 9mm thick tiling) to skirtings, treads, risers, curbs, nosing and returns, bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified: 260 261 Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width. Glazed porcelain ceramic floor tiles of approved colours, patterns (nominal size 600 x 600 x 10mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Glazed porcelain ceramic floor tiles of approved colours, patterns (nominal size 500 x 500 x 10mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Heavy duty unglazed ceramic floor tiles of approved colours, patterns and textures (nominal size 200 x 200 x 8mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Heavy duty unglazed ceramic floor tiles of approved colours, patterns and textures (to match 200 x 200 x 8mm thick tiling) to skirtings, treads, risers, curbs, nosing and returns, bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified: 265 266 Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width. Heavy duty unglazed ceramic floor tiles of approved colours, patterns and textures (nominal size 300 x 300 x 9mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. m m 11.70 19.30 SD101 SD102 m m 9.80 15.80 SD065 SD066

262

57.80

SD119

263

54.40

SD118

264

50.40

SD100

267

51.70

SD097

Page 39 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) FLOOR FINISHES (CONT'D) Heavy duty unglazed ceramic floor tiles of approved colours, patterns and textures (to match 300 x 300 x 9mm thick tiling) to skirtings, treads, risers, curbs, nosing and returns, bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified:

CODE

268 269

Not exceeding 150mm in height/width. Exceeding 150mm but not exceeding 300mm in height/width. Glazed ceramic round edge skirting tile 400x80x8mm thick of approved colour and textures bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Heavy duty structured/textured ceramic floor tile (nominal size 300x300x9mm thick) bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Heavy duty polished homogeneous floor tiles of approved colours, patterns and textures, (nominal size 400 x 400 x 9mm thick), bedded on and including prepacked screed and pointing with approved coloured tile grouts as specified. Extra over ceramic floor tiles for prepacked waterproof screed in lieu of prepacked screed. Coloured interlocking concrete paving blocks to approved pattern including 50mm thick compacted sand bed as specified:

m m

10.90 17.80

SD098 SD099

270

14.00

SD115

271

49.70

SD114

272

56.20

SD111

273

m2

1.60

SD113

274 275 276 277

224 x 110.5 x 80mm thick. 225 x 111 x 100mm thick. 453 x 453 x 100mm thick. 600 x 600 x 50mm thick concrete paving slab of grade 25 concrete with 10mm max. aggregate jointed with prepacked mortar as specified. 20 x 25mm PVC "L" shaped Floor Strip laid to fall, secured to reinforced concrete floor slab with masonry nails at 500mm centre to centre and top of strip to be flushed with concrete screed as specified.

m m m m

29.50 30.90 32.70 16.90

SD077 SD078 SD079 SD080

278

3.10

SD084

Page 40 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) ROOFING

CODE

279

BRC 3315 to roof to support sisalation paper. Woodwool slab to roof:

2.60

SE001

280 281 282

25mm thick. 50mm thick. 900 x 600 x 20mm thick ferrocement secondary roof slabs, reinforced with galvanised fine mesh to reinforced concrete flat roof including all necessary supporting concrete solid blocks, labour and materials for sealing up pipes etc as specified. 3mm thick acrylic polymer modified cementitious coating to roof surfaces and gutter as specified. Panel Roofing System to roof surfaces consisting of 38mm thick waterproofing cement and sand panel (1:3), 50mm thick Styrofoam insulation board or other approved and 6 coats of waterproofing membranes, 1 layer of open woven glass membrane and a minimum of 20mm thick waterproofing cement and sand screed (1:3) laid to fall as specified and including all necessary materials for jointing (measured flat on plan - rate inclusive of the provision of a 10 year warranty). One layer of "Parsec Thermo-brite II" double sided reflective roof heat insulation sheet including lapping with "Parsec Thermo-brite" tape and secured to roof structure by self-drilling fasteners complete with metal washers as specified and in accordance with Manufacturer's instructions. One layer of "Super Sisalation" double sided reflective roof heat insulation sheet including lapping with PPC 493 reinforced aluminium foil tape and secured to roof structure by self-drilling fasteners complete with metal washers as specified and in accordance with Manufacturer's instructions. One layer of "Super Brite" double sided reflective roof heat insulation sheet including lapping and secured to roof structure by self-drilling fasteners complete with metal washers as specified and in accordance with Manufacturer's instructions.

m m m

39.20 51.70 36.30

SE005 SE045 SE048

283

10.90

SE049

284

53.40

SE008

285

9.20

SE034

286

8.00

SE035

287

7.80

SE047

Page 41 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) ROOFING (CONT'D) Colourbond XRW metal roofing sheets including all necessary fixing accessories as specified (rate inclusive of the provision of a 10-year warranty):

CODE

288 289 290 291

0.47mm thick Lysaght Spandek 0.47mm thick Lysaght Trimdek 0.53mm thick Lysaght Kliplok 0.65mm thick Lysaght Kliplok 0.60mm thick custom made colourbond XRW flashings/cappings/trims to Kliplok/Spandek roofing including all necessary fixing accessories as specified (rate inclusive of the provision of a 10-year warranty):

m m m m

31.90 32.70 40.40 48.10

SE014 SE046 SE015 SE016

292 293 294 295 296 297

not exceeding 100mm girth. exceeding 100mm but not exceeding 200mm girth. exceeding 200mm but not exceeding 300mm girth. exceeding 300mm but not exceeding 400mm girth. exceeding 600mm but not exceeding 800mm girth. 0.53mm thick Lysaght Speed Deck colorbond metal roofing including all necessary fixing accessories as specified (rate inclusive of the provision of a 10-year warranty). Colorbond ridge capping (type A) to Lysaght Speed Deck roofing including all necessary fixing accessories as specified (rate inclusive of the provision of a 10-year warranty).

m m m m m m

8.80 12.60 15.60 20.90 32.20 46.90

SE019 SE020 SE021 SE022 SE025 SE012

298

35.60

SE013

Page 42 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CARPENTRY AND JOINERY Approved calcium silicate board as ceiling board including corrosion resistant countersunk screws fixed to timber joists as specified (timber joists and painting measured separately):

CODE

299 300 301

9mm thick. 12mm thick. Ceiling duct for concealment of discharge pipes and fittings comprising of 9mm thick calcium silicate board with galvanised steel angle frames, including egg crate chrome plastic lighting diffuser with powder coated aluminium frames as specified. (measurement based on exposed surface area of duct and painting measured separately) 9mm thick calcium silicate board as box-up for concealment of gas pipes complete with 40 x 40 x 3mm thick galvanised steel angle frames/supports as specified (painting measured separately). Approved calcium silicate board with 1-hour compartmentation as box-up for concealment of gas pipes complete with galvanised steel angle frames/supports as specified (painting measured separately). Extra over items SF208 and SF209 for forming 15mm diameter ventilation holes at 300mm centres Sawn timber in wall plates, rafters, purlins, joists, collars and backing pieces. Extra over structural timber for pressure impregnation treatment with approved wood preservative. Wrot timber for BOARDS under 50mm thick and 100mm or more wide including all labour and materials for any necessary jointings. Wrot timber for frame, head, mullion, transome or cill worked to the required shape. Wrot timber for hand rails not exceeding 5,000 mm in sectional area.

m m m
2

16.00 20.60 75.90

SF128 SF049 SF204

302

51.40

SF208

303

81.50

SF209

304

0.90

SF210

305

1,330.00

SF004

306

82.20

SF005

307

1,344.50

SF006

308

1,539.10

SF007

309

18.20

SF010

Page 43 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CARPENTRY AND JOINERY (CONT'D) Wrot timber for architraves, cover fillets, etc:

CODE

310 311

not exceeding 500 mm in sectional area. exceeding 500 mm but not exceeding 1,000 mm in sectional area. Wrot timber for louvre blades:

m m

1.70 2.20

SF008 SF009

312 313

not exceeding 2,000 mm in sectional area. exceeding 2,000 mm but not exceeding 4,000 mm in sectional area. Boarding in shelving, partitions, panellings, etc screwed on:

m m

3.70 5.10

SF011 SF012

314 315 316

19mm thick. 25mm thick. Teak or other approved timber hardwood strip flooring comprising of 70mm wide x 350-450mm long x 12mm thick tongued and grooved timber strips jointed together and laid to approved patterns including sanding and polishing to approval and painting surfaces with 3 coats varnish as specified (cement screed measured 95mm high timber skirting comprising of 95mm wide x 1200mm long x 11mm thick timber strips including sanding and polishing to approval and painting surfaces with 3 coats varnish as specified. 45mm thick solid cored timber door comprising of 33mm thick tongued and grooved jointed boards fixed together with 3nos 10mm diameter bolts and filled in both faces with 6mm thick plywood lining as specified (door frame and ironmongery measured separately):

m m m
2

37.40 44.20 97.40

SF013 SF014 SF205

317

18.60

SF206

318

Single-leaf door Type DT2A, D1/D1A or ST1 for opening of 1000 x 2190mm height. Double leaf door Type DT2B or ST2 for opening of 1500 x 2190mm height.

no

405.90

SF096

319

no

617.70

SF094

Page 44 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CARPENTRY AND JOINERY (CONT'D) 38mm thick single-leaf semi-cored timber flush door with 6mm thick plywood lining on both faces as specified (door frame, calcium silicate panel and ironmongery measured separately):

CODE

320

Type DT1B/DF1B for opening 450 x 2190mm height.

no

190.10

SF164

321

Type DT1C/DF1C for opening 500 x 2190mm height.

no

193.90

SF165

322

Type DT1E/DF1E for opening 650 x 2190mm height.

no

200.20

SF167

323

Type DT1F/DF1F for opening 750 x 2190mm height.

no

209.80

SF168

324

Type DT1G/DF1G for opening 850 x 2190mm height.

no

221.30

SF169

325

Type HT/1 or HTF/1 for opening of 380 x 2190mm height. Type HT/2 or HTF/2 for opening of 530 x 2190mm height. Type HT/3 or HTF/3 for opening of 780 x 2190mm height. Type HT/4 or HTF/4 for opening of 880 x 2190mm height. 38mm thick single-leaf semi-cored timber flush door with fixed timber louvres on top and 6mm thick plywood lining on both faces as specified (door frame, calcium silicate panel and ironmongery measured separately):

no

186.20

SF192

326

no

193.80

SF193

327

no

214.40

SF194

328

no

237.60

SF195

329

Type DL1C/DFL1C for opening 500 x 2190mm height. Type DL1E/DFL1E for opening 650 x 2190mm height.

no

167.20

SF175

330

no

185.60

SF177

331

Type DL1F/DFL1F for opening 750 x 2190mm height.

no

196.10

SF178

332

Type DL1G/DFL1G for opening 850 x 2190mm height.

no

205.10

SF179

Page 45 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CARPENTRY AND JOINERY (CONT'D)

CODE

333

12mm thick calcium silicate fixed panel to top of door complete with supporting frames as specified. 23mm thick fixed timber louvred service closet door in 4leaves (2 tops & 2 bottoms) to opening size 700x2190mm height with 30x6mm thick fixed timber lourves and timber door knobs (timber frames measured separately).

48.80

SF187

334

no

368.50

SF212

335

38mm thick semi-solid timber toilet door with high pressure plastic laminated on both sides as specified to opening size 900x2190mm (door frame and ironmongery measured separately) 38mm thick single-leaf solid timber bedroom door Type DM4, DM5 and DM6 with approved veneered plywood facing and decorative inlays on both sides complete with varnish as specified to opening size of 975x2190mm height (door frame and ironmongery measured separately). 38mm thick single-leaf semi-solid timber bedroom door Type DM4, DM5 and DM6 with approved veneered plywood facing and decorative inlays on both sides complete with varnish as specified to opening size of 900x2190mm height (door frame and ironmongery measured separately). 45mm thick solid timber main entrance door Type DM1, DM2 and DM3 with approved veneered plywood facing and decorative inlays on both sides and complete with mild steel door frame, varnish, approved ironmongery as specifed to opening size of 1000x2190mm height.

no

451.10

SF217

336

no

455.50

SF214

337

no

419.30

SF218

338

no

831.10

SF216

339

45mm thick half-hour fire-rated solid timber main entrance door Type FDM1A, FDM2A and FDM3A with approved veneered plywood facing and decorative inlays on both sides and complete with mild steel door frame, varnish, approved ironmongery as specifed to opening size of 1000x2190mm height.

no

902.60

SF215

Page 46 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CARPENTRY AND JOINERY (CONT'D) 45mm thick double-leaf half-hour fire rated timber surface finished composite door complete with 100 x 63mm timber door frame, all necessary ironmongery and accessories as specified:

CODE

340 341

Type FDT2F for opening of 1500 x 2190mm height. Type FST2 for opening of 1500 x 2190mm height.

no no

920.20 928.90

SF089 SF202

45mm thick single-leaf half-hour fire rated timber surface finished composite door complete with 100 x 63mm timber door frame, all necessary ironmongery and accessories as specified (fire-rated removable panel measured separately) : 342 Type FDT1B/FDF1B for opening of 450 x 2190mm height. Type FDT1C/FDF1C for opening of 500 x 2190mm height. Type FDT1E/FDF1E for opening of 650 x 2190mm height. Type FDT1F/FDF1F for opening of 750 x 2190mm height. Type FDT1G/FDF1G for opening of 850 x 2190mm height. Type FDT2H for opening of 1000 x 2190mm height. no 486.80 SF145

343

no

491.40

SF146

344

no

517.10

SF148

345

no

527.60

SF149

346

no

543.70

SF150

347

no

593.60

SF091

348 349

Type FST1 for opening of 1000 x 2190mm height. Type FDT2J for opening of 1000 x 2190mm height with clear glass observation panel size 150 x 300mm.

no no

646.00 607.50

SF201 SF092

350

45mm thick half-hour fire rated removal timber panel with 3mm thick plywood finish on both sides and complete with 100x63mm thick timber frame to service duct above door panel.

262.60

SF207

Page 47 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) CARPENTRY AND JOINERY (CONT'D) Approved waterproofed plywood shelves, partitions and the like: in panels for

CODE

351 352 353 354 355

6mm thick . 9mm thick . 12mm thick. 18mm thick. 25mm thick.

m m m m m

15.60 18.40 21.70 23.30 28.70

SF033 SF034 SF035 SF036 SF037

Page 48 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) IRONMONGERY Brass lever action flush bolt in satin finish:

CODE

356 357

200 x 20mm wide. 300 x 20mm wide. Stainless steel shoot bolt:

no no

9.30 11.50

SG091 SG092

358 359

90 x 27mm barrel/square shoot bolt. 240 x 27mm barrel/square shoot bolt. Stainless steel lever action flush bolt:

no no

5.70 8.00

SG013 SG014

360 361

225 x 25mm wide. 150 x 25mm wide. Stainless steel lever action box type flush bolt in satin finish:

no no

9.90 8.90

SG072 SG073

362 363

200 x 20mm wide. 300 x 20mm wide. Stainless steel butt hinges (grade 304):

no no

9.30 9.90

SG123 SG124

364 365 366

100 x 70 x 1.5/1.7/1.8mm (0.2mm) thick. 102 x 76 x 2.0mm thick. 102 x 76 x 3mm thick satin finished solid brass hinges with flat button tip and ball bearing. Nickel plated cabinet spring hinge. Cabin hook and eye:

no no no

4.90 4.90 7.40

SG141 SG075 SG090

367

no

1.90

SG137

368 369

80mm brass. 100mm stainless steel. 4mm thick stainless steel plate locking eyes for:

no no

8.90 11.70

SG080 SG041

370 371

Single leaf door. Double leaf door.

set set

13.80 16.10

SG096 SG093

Page 49 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) IRONMONGERY (CONT'D)

CODE

372 373

95mm stainless steel bow handle. 18mm diameter (min) x approximate length 225mm stainless steel pull handle Tiki PH-20/BB/225SS. 300 x 150 x 1.2mm thick stainless steel push plate. 150mm Stout hasp and staple. Aluminium die cast single panic bolt with extruded aluminium guides in silver colour finish Accord 376 for single door complete with cylinder panic lock. Solid brass magnetic door holder. Antique brass finish door viewer. Slim line door closer with cushioned back checking action as specified Rebated 5 pin double cylinder mortice lockset complete with brass chromium plated/stainless steel handle as specified

no no

6.30 18.10

SG079 SG110

374 375 376

no no no

24.60 21.20 252.80

SG111 SG078 SG116

377 378 379

no no no

9.70 8.00 48.60

SG136 SG040 SG142

380

no

78.30

SG143

Page 50 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) IRONMONGERY (CONT'D)

CODE

381

Rebated 5 pin single cylinder antique brass mortice lever on backplate lockset complete with thumb turn and solid brass lever handles on both sides for entrance door as specified Cylinder mortice night latch with chromium plated finish including the provision of keys as specified Antique brass finish lever handle lockset with 5-pin single cylinder and thumb turn (key on outside and thumb turn on inside) with lver handles on both sides for bedroom door as specified Antique brass finish lever handle lockset with emergency release on outside and thumb turn on inside with lever handles on bothsides for bathroom door as specified Antique brass finish 5 pin tumbler single cylinder knobset (with key on the outside and push button on the inside) for bedroom door as specified. Antique brass finish privacy knobset with emergency release on the outside and push button on the inside for bathroom door as specified. Privacy knobset with emergency release as specified: Cylinder deadlock as specified:

no

80.70

SG144

382

no

91.00

SG145

383

no

72.70

SG150

384

no

68.50

SG151

385

no

25.10

SG139

386

no

22.90

SG138

387 388

no no

21.10 91.00

SG146 SG147

Page 51 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) IRONMONGERY (CONT'D) Padlock under master key as specified:

CODE

389 390 391 392 393 394 395 396 397 398 399

Union 3104-50mm. Union 3142. Union 3122/2 PL. Yale 110.30. Yale 110.50. Yale 110.60. Abloy 330C/25. Abloy 320C/20 Abloy 330C/25 under key alike series Stainless steel cup handle as specified Stainless steel cup handle passage latch with cup handles on both sides as specified Brass rebated part for lockset.

no no no no no no no no no no no

15.50 31.10 16.60 12.90 17.90 25.00 32.10 32.10 45.00 10.80 29.80

SG061 SG062 SG106 SG063 SG105 SG064 SG065 SG127 SG095 SG148 SG149

400

no

9.20

SG094

Page 52 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK Galvanised steel Class 'A' pipe bent to shape and fixed as rails including necessary bends, tees, etc welded (masonry work measured separately):

CODE

401 402 403 404 405

50mm diameter. 40mm diameter. 30mm diameter. 20mm diameter. Galvanised wrought iron holdfast 25x230x3mm, one end screwed to door or window frames and the other end fishtailed and built into joints of brick or block walls, or cast into reinforced concrete walls/columns. Heavy duty hot-dipped galvanised steel grating comprising of 65x9mm thick flats as framing, 65x9mm thick intermediate flats spaced at 30mm centres resting on 12mm diameter rods at 85mm centres and supporting on 75x75x9.4mm thick angle frame anchored to concrete structure with mild steel fish tail. Heavy duty hot-dipped galvanised steel grating comprising of 65x9mm thick flats as framing, 50x9mm thick intermediate flats spaced at 30mm centres resting on 10mm diameter rods at 75mm centres and supporting on 75x75x9.4mm thick angle frame anchored to concrete structure with mild steel fish tail. Heavy duty hot-dipped galvanised steel grating comprising of 65x10mm thick flats as framing, 55x10mm thick intermediate flats at 30mm centres resting on 10mm diameter bars at 75mm centres and supporting on 75x60x8mm thick angle frame anchored to concrete structure with mild steel fish tail. 300mm wide hot dipped galvanised steel grating over apron drain comprising of 50x8mm thick galvanised steel flats as framing infilled with 10 nos 25x6mm thick galvanised steel flats resting on 25x6mm thick galvanised steel flat supports at 200mm centres as specified.

m m m m no

15.40 11.80 10.60 8.10 1.50

SH469 SH470 SH471 SH472 SH410

406

808.50

SH475

407

734.70

SH590

408

681.40

SH714

409

78.30

SH658

Page 53 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D)

CODE

410

300x600mm hot dipped galvanised steel hinged grating over apron drain comprising of 32x9mm thick galvanised steel flats as framing infilled with 9 nos 25x6mm thick galvanised steel flats resting on 2 nos 25x6mm thick galvanised steel flats and supported on 64x38x4.5mm thick galvanised steel angle frame anchored to concrete structure as specified. 300x600mm hot-dipped galvanised hinged grating complete with 3mm thick galvanised mild steel chequered plate over reinforced concrete apron drain as specified.

no

63.80

SH659

411

no

62.70

SH568

412

0.8mm thick galvanised steel motorised roller shutter (with ventilation holes) finished with colourbond silicone modified polyester coating complete with channel guide, shutter motor, angle bolts, bottom rail, auto-stop safety device, push-button switches in weatherproof control box with utility lock and all necessary components in accordance with Manufacturer's instructions to centralised refuse chamber with approximate overall size 3400mm (min) wide x 3800mm height to underside of motor casing. 0.5mm (minimum) thick zincalume steel motorised roller shutter (with ventilation holes) finished with colourbond silicone modified polyester coating complete with channel guide, shutter motor, angle bolts, bottom rail, auto-stop safety device, push-button switches in weatherproof control box with utility lock and all necessary components in accordance with Manufacturer's instructions to centralised refuse chamber with approximate overall size 3400mm (min) wide x 3800mm height to underside of motor casing. Galvanised steel grille panel over parapet at staircase & access balcony comprising of 50x50x1.6mm thick hollow section frame filled in with 18x9mm thick flats spaced at not more than 100mm centres welded on to frame and the panel fixed to wall with 38x9mm fishtail holdfast. Galvanised steel railing 900mm high at staircase comprising of 18x9mm thick flat baluster spaced at not more than 100mm centres and 25x25x1.6mm thick hollow section supports at not more than 1200mm centres, all welded to 43mm diameter x 1.6mm thick hollow section handrail and 38x9mm thick flat bottom rail and the support cast into concrete curb.

no

3,650.00

SH411

413

no

3,984.80

SH489

414

129.00

SH707

415

94.80

SH708

Page 54 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D)

CODE

416

Galvanised steel grille panel comprising of 50x50x6mm thick hollow section framings filled in with 19x10x1.2mm thick hollow section members welded to the frame and panel fixed to wall with 25x25x2.2mm thick hollow section supports. Mild steel Grade 43A for flats, angles, tees, channels, hollow sections, square sections, rivets and bolts, etc. of any size fabricated and fixed including welding or bolting, and painting with one coat of lead and chromate-free primer (for structural steel work only). Mild steel flats, angles, tees, channels, rivets and bolts, etc. of any size fabricated and fixed including welding or bolting (for non-structural steel work only). Extra over mild steel rods, flats, angles, tees, channels, hollow sections, rivets, bolts, etc for galvanising in lieu of painting one coat of lead and chromate-free primer. Extra over mild steel rods, flats, angles, tees, channels, hollow sections, rivets, bolts, etc for galvanising. 13mm diameter mild steel fan hook to concrete surface of ceiling. Ramset Nail No.2330 or equal and approved including use of gun and explosive charges. Mild steel blast door BD4 for household shelter complete with mild steel door frames, hinges, locking device, stainless steel handles ventilation sleeve and plate units, etc including approved primer as specified. Wrought iron steel gate Type MG4, MG5 and MG6 fixed to metal door frame of entrance door of opening size 1000x2190mm height complete with approved ironmongery, wrought iron house number plate and painting as specified.

87.60

SH587

417

kg

5.50

SH018

418

kg

4.80

SH019

419

kg

0.50

SH670

420

kg

0.80

SH584

421

no

5.90

SH022

422

no

0.50

SH023

423

no

1,092.50

SH671

424

no

552.00

SH715

Page 55 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Mild steel door frame fixed into door openings in accordance with Board's Standard Drawings including one coat of approved primer and all necessary fittings and hinges, all as specified:

CODE

425

90 x 45 x 1.6mm thick jamb to opening size 900mm width x 2190mm height. 130 x 45 x 1.6mm thick jamb to opening size 900mm width x 2190mm height. 70 x 60 x 1.6mm thick jamb to opening size 1000mm width x 2190mm height. 3.175mm B.G. x 50mm PVC coated mesh Chain Link Fencing of the following heights, to top of mesh with 3 nos. horizontal lines of double strand 2.517mm B.G. galvanised barbed wire above at 100mm centres, the chain link and barbed wires fixed to and including 50x50x6mm angle iron posts at 3m centres with top bent to form spurs and bottom cast in 300x300x450mm deep concrete (1:3:6) foundations including all necessary straining and tying wires and split pins and priming and painting posts with one coat aluminium paint:

no

81.20

SH062

426

no

92.70

SH073

427

no

104.40

SH084

428 429 430 431 432 433

1.20m high. 1.50m high. 1.80m high. 2.10m high. 2.40m high. 625mm high fluorocarbon coated aluminium sunbreaker comprising of 50.8mm diameter x 3mm thick aluminium CHS frames filled in with 3mm thick aluminium perforated sheets and fixed according to PE's recommendations as specified (rate inclusive of the provision of 10-year warranty). 0.7mm thick aluminium false ceiling comprising of 600 x 600mm double coated polyester stove enamelled colour aluminium tiles complete with all fixing accessories, suspension hangers, etc in accordance to Manufacturer's instructions. 3mm thick aluminium chequered plate cover to bulk meter sump complete with stainless steel handle, hinges and welded to and including galvanised steel frames.

m m m m m m

34.20 37.80 43.40 47.80 60.10 157.30

SH009 SH011 SH013 SH015 SH017 SH672

434

95.50

SH585

435

m2

229.70

SH709

Page 56 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Natural anodised aluminium door comprising of 97 x 42 x 2.3mm thick natural anodised aluminium top rail and stiles, and 120x42x2.3mm thick middle and bottom rails filled in with 2.3mm thick natural anodised aluminium louvres complete with 2.3mm thick galvanised steel door frame and all necessary ironmongery and accessories as specified:

CODE

436

Single leaf door Type DT5 for opening of 900 x 2190mm height. Double-leaf door Type D7A for opening of 1500 x 2190mm height. Natural anodised aluminium door comprising of 40 x 30 x 3mm thick aluminium stiles, top, bottom and intermediate rails covered with 2mm thick aluminium flat sheet on both faces and fill in with rockwool (density: 60kg/m) complete with 2.3mm thick aluminium door frame and all ironmongery and accessories as specified:

no

1,605.60

SH420

437

no

2,075.70

SH479

438

Single-leaf door Type DT2G/DT2J for opening of 1000 x 2190mm height. Double-leaf door Type DT2E for opening of 1500 x 2190mm height. Natural anodised aluminium door comprising of 100 x 42 x 2.3mm thick aluminium stiles, top, bottom and intermediate rails covered with 2mm thick aluminium flat sheet on both faces complete with 2.3mm thick aluminium door frame and all ironmongery and accessories as specified:

no

1,545.00

SH599

439

no

2,514.10

SH597

440

Single-leaf door Type STM1 for opening of 1000 x 2190mm height. Double-leaf door Type STM2 for opening of 1500 x 2190mm height.

no

1,801.50

SH681

441

no

2,789.30

SH682

Page 57 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Natural anodised aluminium door comprising of aluminium supports and bracings covered with 2mm thick aluminium flat sheet on both faces and filled in with rockwool complete with aluminium refuse hopper, fixed aluminium louvred vent and 2.3mm thick aluminium door frame and all ironmongery and accessories as specified:

CODE

442

Single leaf door Type DT6 for opening of 1000 x 2190mm height. Double-leaf door Type DT6B for opening of 1500 x 2190mm height. Heavy duty natural anodised aluminium louvred door for ESS comprising of 2.3mm thick aluminium louvres complete with 2mm thick aluminium door frame including ironmongery all as specified:

no

2,023.50

SH600

443

no

2,755.70

SH602

444

Double-leaf door Type ALD/1 for opening of 2700 x 2700mm height. Double-leaf door Type ALD/2 for opening of 1800 x 2900mm height. Heavy duty natural anodised aluminium flush door for ESS complete with 2mm thick aluminium door frame including ironmongery all as specified:

no

3,271.00

SH574

445

no

2,681.00

SH579

446

Single-leaf door Type AFD/3 for opening of 900 x 1500mm height. Double-leaf door Type AFD/4 for opening of 1800 x 1500mm height. Single-leaf door Type AFD/5 for opening of 900 x 2200mm height. Bronze anodised aluminium louvred vent at service duct complete with frame filled in with 2.3mm thick extruded aluminium louvred blades for:

no

1,558.30

SH711

447

no

2,668.80

SH712

448

no

1,721.40

SH713

449 450

Opening size 615 x 400mm height. Opening size 310 x 900mm height.

no no

132.30 146.30

SH605 SH606

Page 58 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D)

CODE

451

Three-way natural anodised aluminium letter box with antijunk mail device in accordance with Board's Standard Drawings including master doors, locks and keys and engraving with house numbers, block numbers and street name to top frame of letter box (masonry work measured separately). Block number numeral size 500mm high x 35mm deep made to profile, with 1.5mm thick bronze anodised aluminium sheet and fixed to wall with aluminium extruded sections as specified. Anodised aluminium motorised roller shutter (with ventilation holes) with channel guide, shutter motor, angle bolts, bottom rail, auto-stop safety device, push-button switches in weatherproof control box with utility lock and all necessary components in accordance with Manufacturer's instructions:

no

86.30

SH717

452

no

44.30

SH559

453

Approximate size 3400mm wide (min) x 3800mm height to underside of motor casing for centralised refuse chamber comprising of 1.6mm thick extruded aluminium curtain interlocking slats. Approximate size 2100mm wide (min) x 2100mm height to underside of motor casing for utilities centre comprising of 1.6mm thick extruded aluminium curtain interlocking slats. Aluminium alloy inspection door overall size 550 x 800mm comprising of 1.2mm thick aluminium sheets to both faces supported with aluminium "C" channel bracings complete with aluminium frames, 100mm stainless steel butt hinges and cam lock to manufacturer's details.

no

3,910.00

SH412

454

no

966.00

SH607

455

no

386.20

SH414

Page 59 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D)

CODE

456

40mm thick inspection cover for refuse chute overall size 1140 x 1140mm to top of refuse chute comprising of 1.2mm thick anodised aluminium alloy sheets on both faces supported with 1.2mm thick galvanised steel "C" channel bracings and infilled with rockwool insulation complete with 5mm thick extruded aluminium section framings including stainless steel friction stay, hinges and hot dipped galvanised steel safety mesh supported on galvanised steel angle, etc to manufacturer's details.

no

652.40

SH413

457

Aluminium catladder approximately 450mm wide comprising of aluminium 'U' channel handle, 25mm diameter tubular aluminium rungs, complete with aluminium hooks, brackets, rubber cappings and all necessary fixing accessories as specified. Aluminium retractable ladder overall 2900mm long comprising of aluminium 'C' channel, aluminium hooks, 25mm diameter aluminium rungs spaced at 305mm apart and complete with 2 sets of aluminium fixing brackets including all necessary fixing accessories as specified.

97.70

SH586

458

no

271.70

SH129

459

Aluminium retractable ladder overall 5700mm long comprising of aluminium 'C' channel, aluminium hooks, 25mm diameter aluminium rungs spaced at 305mm apart and complete with 5 sets of aluminium fixing brackets including all necessary fixing accessories as specified.

no

948.40

SH130

460

Aluminium cage guard comprising of 6 nos. of 32mm diameter (external) aluminium pipes spaced not more than 650mm apart with 38x6mm thick vertical aluminium flats rivetted to pipes and including all necessary fixing accessories as specified. Purpose made aluminium handrails to roof top access opening comprising of 32mm diameter (external) aluminium pipe bent to shape and welded with 10mm thick aluminium plates and including all necessary fixing accessories as specified. Bronze anodised extruded aluminium framed adjustable louvred vents complete with aluminium 'U' clips/holders, 6mm thick obscure wired rough cast glass louvres and all necessary fixing and jointing materials and accessories as specified (measurement based on size of opening).

no

166.10

SH131

461

pr

388.90

SH132

462

498.50

SH677

Page 60 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D)

CODE

463

Bronze anodised extruded aluminium framed fixed louvred vent complete with 2.3mm thick extruded bronze anodised aluminium louvred blades, and all necessary fixing and jointing materials and accessories as specified (based on size of opening). Bronze anodised extruded aluminium framed window complete with 5mm thick green grey/grey tinted float glass and ironmongery and all necessary fixing and jointing materials and accessories as specified (measurement based on size of opening):

405.40

SH678

464 465 466 467 468

Top hung casement window. Top and side hung casement windows. 2-track sliding window with top hung casement. 3-track sliding window with top hung casement. Bronze anodised extruded aluminium framed sliding door complete with 6mm thick green grey/grey tinted float glass, ironmongery and jointing materials and accessories as specified (measurement based on size of opening). Bronze anodised extruded aluminium framed fixed louvred vent for ESS complete with 2.3mm thick extruded bronze anodised aluminium louvred blades and all necessary fixing and jointing materials and accessories as specified (measurement based on size of opening).

m m m m m

438.20 355.10 304.80 303.00 194.60

SH673 SH674 SH675 SH676 SH680

469

340.10

SH706

Page 61 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) 2mm thick natural anodised aluminium sign plate with helvetica medium letters and figures/symbols engraved in black/red colour including fixing with stainless steel screws as specified:

CODE

470 471 472

200/220 x 25mm services duct signage. 300 x 300mm 'No Smoking' sign plate. 700mm to 1000mm long x 120mm high sign plates for services rooms. 700mm to 1000mm long x 120mm high warning sign plate for consumer switch room. 2mm thick natural anodised aluminium sign plate with folio caravelle bold letters and figures/symbols engraved in red colour including fixing with stainless steel screws as specified :

no no no

7.70 20.70 29.60

SH480 SH582 SH468

473

no

29.60

SH142

474

70mm height x width of door leaf (approximately 290mm to 790mm) with the wordings "Wet Rising Main Outlet", "Dry Rising Main Inlet", "Fire Hose Reel" or "Down Comer Outlet". 130mm height x width of door leaf (approximately 290mm to 790mm) with the wordings "Wet Rising Main Outlet", "Dry Rising Main Outlet", "Wet Rising Main Inlet", "Dry Rising Main Inlet" or "Down Comer Outlet". Signplate to multi-storey carpark comprising of 2mm thick natural anodised aluminium plate with approved Engineer's grade reflective sheets with helvetica medium letters and figures/symbols fixed to wall as specified:

no

19.30

SH660

475

no

19.30

SH661

476 477 478 479

450 x 250mm. 450 x 450mm. 600 x 250mm. 600 x 450mm.

no no no no

27.80 52.80 36.40 57.90

SH704 SH591 SH705 SH592

Page 62 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D)

CODE

480

Height limit signboard comprising of 600 x 600 x 2mm thick aluminium plate with approved Engineer's grade reflective sheets and letterings on one face mounted on and including 50 x 50 x 6mm thick mild steel hollow section with base plate set in concrete (1:2:4) foundation and all necessary excavation as specified. External clothes drying racks consist of stainless steel clothes drying racks extrusion with 3 nos of fixed stainless steel poles, bend sections and all necessary components fixed to structure as specified, Internal retractable clothes drying racks consist of stainless steel poles (for wall mounted) or aluminium extrusion poles (for ceiling mounted); brackets, links, fasteners and all necessary components fixed to structure as specified. Complete set of clothes drying racks at recess area comprising of 2 nos aluminium racks and stainless steel railings of approximate size 2800 x 1250mm height as specified. 2mm thick grade 304 hair-line finish stainless steel plate signage with letterings and graphics engraved, all as specified:

no

126.50

SH593

481

set

621.00

SH112

482

set

517.50

SH113

483

set

948.80

SH571

484 485 486

200 x 200mm signage for central refuse chute. 300 x 300mm plaque at 1st storey lift entrance. Foot-operated grade 304 stainless steel refuse chute hopper to centralised refuse chute complete with all necessary fixing accessories as specified.

no no no

19.40 28.20 862.50

SH416 SH417 SH476

Page 63 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Stainless steel pipe for railing purposes including all necessary cutting, welding, polishing, bending to shape and fixing on site.(Measurement based on length of stainless steel pipes)

CODE

487 488 489 490 491 492 493 494 495 496

19.1mm diameter x 1.0mm thick. 19.1mm diameter x 1.2mm thick. 25.4mm diameter x 1.0mm thick. 25.4mm diameter x 1.5mm thick. 31.8mm diameter x 1.5mm thick. 31.8mm diameter x 2.0mm thick. 38.1mm diameter x 1.5mm thick. 38.1mm diameter x 2.0mm thick. 50.8mm diameter x 1.5mm thick. 50.8mm diameter x 2.0mm thick. Stainless steel square tube for railing purposes including all necessary cutting, welding, polishing, bending to shape and fixing on site. (Measurement based on length of stainless steel square tube)

m m m m m m m m m m

25.40 25.90 31.60 33.60 41.00 44.00 47.80 51.30 60.50 65.50

SH687 SH688 SH689 SH690 SH691 SH692 SH693 SH694 SH695 SH696

497 498 499 500 501 502 503

19.1mm x 19.1mm x 1.2mm thick. 25.4mm x 25.4mm x 1.5mm thick. 31.8mm x 31.8mm x 1.5mm thick. 38.1mm x 38.1mm x 1.5mm thick. 40.0mm x 40.0mm x 2.0mm thick. 50.8mm x 50.8mm x 2.0mm thick. Stainless steel flats, angles, plates, channels, bolts, etc including cutting, welding, polishing and fixing on site complete with other fixing accessories.

m m m m m m kg

29.90 38.60 46.00 54.10 59.20 75.30 21.50

SH697 SH698 SH699 SH700 SH701 SH702 SH703

Page 64 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Galvanised heavy duty expansion anchor including stud anchor, nut and washer : bolt

CODE

504

8mm anchor diameter x 95mm long (Hilti HSL 3M8/20). 8mm anchor diameter x 115mm long (Hilti HSL 3M8/40). 10mm anchor diameter x 107mm long (Hilti HSL 3M10/20). 12mm anchor diameter x 120mm long (Hilti HSL 3M12/25). 12mm anchor diameter x 145mm long (Hilti HSL 3M12/50). 20mm anchor diameter x 183mm long (Hilti HSL 3M20/30). 24mm anchor diameter x 205mm long (Hilti HSL 3M24/30). M10 x 108mm length (Ramset SA10108). M10 x 128mm length (Ramset SA10128). M12 x 98mm length (Ramset SA12098). M12 x 124mm length (Ramset SA12124). M12 x 153mm length (Ramset SA12153). M16 x 149mm length (Ramset SA16149). M16 x 167mm length (Ramset SA16167). M20 x 189mm length (Ramset SA20189). M20 x 219mm length (Ramset SA20219). M24 x 197mm length (Ramset SA24197). M24 x 236mm length (Ramset SA24236).

no

13.30

SH346

505

no

14.60

SH347

506

no

15.60

SH348

507

no

21.50

SH349

508

no

23.80

SH350

509

no

55.90

SH351

510

no

67.40

SH352

511 512 513 514 515 516 517 518 519 520 521

no no no no no no no no no no no

11.20 11.50 12.10 12.90 13.20 15.20 17.90 25.60 26.60 42.10 44.20

SH353 SH354 SH355 SH356 SH357 SH358 SH359 SH360 SH361 SH362 SH363

Page 65 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Galvanised medium duty expansion anchor bolt including stud anchor, nut and washer :

CODE

522

6mm anchor diameter x 65mm long (Hilti HSA M6x65). 6mm anchor diameter x 100mm long (Hilti HSA M6x100). 8mm anchor diameter x 75mm long (Hilti HSA M8x75). 8mm anchor diameter x 115mm long (Hilti HSA M8x115). 10mm anchor diameter x 90mm long (Hilti HSA M10x90). 10mm anchor diameter x 120mm long (Hilti HSA M10x120). 12mm anchor diameter x 110mm long (Hilti HSA M12x110). 12mm anchor diameter x 180mm long (Hilti HSA M12x180). 16mm anchor diameter x 145mm long (Hilti HSA M16x145). 20mm anchor diameter x 170mm long (Hilti HSA M20x170). 6mm anchor diameter x 45mm long (Ramset Trubolt T6045). 6mm anchor diameter x 55mm long (Ramset Trubolt T6055). 6mm anchor diameter x 85mm long (Ramset Trubolt T6085). 8mm anchor diameter x 50mm long (Ramset Trubolt T8050). 8mm anchor diameter x 65mm long (Ramset Trubolt T8065).

no

2.50

SH365

523

no

4.20

SH366

524

no

4.40

SH367

525

no

4.60

SH368

526

no

5.00

SH369

527

no

5.80

SH370

528

no

6.40

SH371

529

no

9.10

SH372

530

no

9.10

SH373

531

no

13.90

SH374

532

no

1.80

SH375

533

no

2.00

SH376

534

no

3.80

SH377

535

no

2.20

SH378

536

no

2.00

SH379

Page 66 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Galvanised medium duty expansion anchor bolt including stud anchor, nut and washer (Cont'd): 8mm anchor diameter x 90mm long (Ramset Trubolt T8090). 8mm anchor diameter x 130mm long (Ramset Trubolt T8130). 10mm anchor diameter x 60mm long (Ramset Trubolt T10060). 10mm anchor diameter x 75mm long (Ramset Trubolt T10075). 10mm anchor diameter x 90mm long (Ramset Trubolt T10090). 10mm anchor diameter x 120mm long (Ramset Trubolt T10120). 12mm anchor diameter x 80mm long (Ramset Trubolt T12080). 12mm anchor diameter x 100mm long (Ramset Trubolt T12100). 12mm anchor diameter x 140mm long (Ramset Trubolt T12140). 16mm anchor diameter x 100mm long (Ramset Trubolt T16100). 16mm anchor diameter x 125mm long (Ramset Trubolt T16125). 16mm anchor diameter x 175mm long (Ramset Trubolt T16175). 20mm anchor diameter x 120mm long (Ramset Trubolt T20120). 20mm anchor diameter x 160mm long (Ramset Trubolt T20160). 20mm anchor diameter x 215mm long (Ramset Trubolt T20215).

CODE

537

no

3.70

SH380

538

no

4.20

SH381

539

no

2.20

SH382

540

no

2.20

SH383

541

no

3.90

SH384

542

no

4.60

SH385

543

no

4.20

SH386

544

no

4.30

SH387

545

no

5.10

SH388

546

no

5.30

SH389

547

no

5.90

SH390

548

no

7.60

SH391

549

no

8.60

SH394

550

no

11.50

SH396

551

no

16.10

SH398

Page 67 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) STRUCTURAL STEELWORK & METALWORK (CONT'D) Chemical Adhesive Galvanised stud anchor including anchor rod, nut and washer :

CODE

552

8mm anchor diameter x 110mm long with chemical capsules (Ramset M8110/CHEM8). 10mm anchor diameter x 130mm long with chemical capsules (Ramset M10130/CHEM10). 12mm anchor diameter x 160mm long with chemical capsules (Ramset M12160/CHEM12). 16mm anchor diameter x 190mm long with chemical capsules (Ramset M16190/CHEM16). 24mm anchor diameter x 300mm long with chemical capsules (Ramset M24300/CHEM24). 8mm anchor diameter x 80mm long with adhesive capsule (Hilti HAS M8 + HVU). 10mm anchor diameter x 90mm long with adhesive capsule (Hilti HAS M10 + HVU). 12mm anchor diameter x 110mm long with adhesive capsule (Hilti HAS M12 + HVU). 16mm anchor diameter x 125mm long with adhesive capsule (Hilti HAS M16 + HVU). 20mm anchor diameter x 170mm long with adhesive capsule (Hilti HAS M20 + HVU). 24mm anchor diameter x 210mm long with adhesive capsule (Hilti HAS M24 + HVU). Chemical Capsule all to manufacturer's instructions:

no

5.50

SH399

553

no

6.40

SH400

554

no

7.80

SH401

555

no

9.90

SH402

556

no

19.90

SH403

557

no

11.30

SH404

558

no

13.50

SH405

559

no

15.90

SH406

560

no

21.90

SH407

561

no

31.20

SH408

562

no

39.50

SH409

563 564 565 566 567 568

Hilti HVU M8. Hilti HVU M10. Hilti HVU M12. Hilti HVU M16. Hilti HVU M20. Hilti HVU M24.

no no no no no no

7.20 8.60 9.70 12.70 16.00 17.70

SH553 SH554 SH555 SH556 SH557 SH558

Page 68 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) WALL AND CEILING FINISHES

CODE

569

Hack existing concrete surface to form keys and wash and clean to receive finishes. Skim coat of approved skimming materials applied from within the building:

3.80

SI001

570 571

To wall. To ceiling. Skim coat of approved skimming materials applied from the external face of the building:

m m

5.10 5.60

SI002 SI004

572 573 574

To wall. To sides and soffit of beam and slab. Skim coating to external RC surfaces in two coats to a maximum total thickness of 6mm using approved skimming materials as specified. Two coats of polymer compound and cement (1:2) mixture (total thickness 2.5mm) to concrete blockwall. 18mm thk plastering with approved PREPACKED MORTAR MIX to RC surfaces, brickwalls and blockwalls etc., applied from within the building as specified. 18mm thk plastering with approved PREPACKED MORTAR MIX to RC surfaces, brickwalls and blockwalls etc., applied from the external face of the building as specified. Extra over plastering for forming 20 x 15mm deep groove lines to walls, columns, beams, etc as specified. Pattern coloured glazed wall tiles size (200 to 300)mm x (200 to 300)mm x 7mm thick of approved colours, patterns and texture to walls including prepacked mortar screed as specified. Extra over pattern coloured glazed wall tiles for laying one course of Listello tiles size 198 x 65mm high.

m m m

6.20 6.60 14.90

SI003 SI005 SI035

575

5.70

SI029

576

18.50

SI037

577

21.50

SI038

578

3.30

SI032

579

46.20

SI039

580

9.60

SI036

Page 69 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) WALL AND CEILING FINISHES (CONT'D) First quality grade Y glazed ceramic tiles of approved colours, patterns and textures to walls including prepacked mortar screed as specified:

CODE

581 582

200 x 200 x 8mm thick (nominal size). Polished homogeneous ceramic tiles of approved colours, patterns and textures (nominal size 300 x 300 x 9mm) to wall surface including prepacked mortar screed as specified.

m m

47.60 61.50

SI033 SI034

Page 70 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION UPVC pipe for rainwater fixed to wall with collar brackets as specified:

CODE

583

200mm diameter. Extra over UPVC rainwater downpipe for fittings:

31.00

SJ324

584 585 586

200mm diameter connector piece. 200 x 50mm diameter junction. 200mm diameter x 275 x 120 mm adaptor UPVC fittings for rainwater downpipe :

no no no

41.60 35.10 120.90

SJ329 SJ387 SJ326

587 588

120 x 275mm rectangular elbow. Rectangular 'Y' branch junction. UPVC pipe for rainwater outlet embedded in concrete floor (concrete measured separately):

no no

148.30 148.20

SJ327 SJ328

589 590 591

200 x 80 x 5mm thick rectangular pipe. 275 x 120 x 5mm thick rectangular pipe. UPVC screw-down domical grating to top of 200mm diameter pipe complete with 240 x 240mm square body. UPVC pipe for underground sewer with flexible joints laid on concrete bed in trench (trench and concrete bed measured separately) :

m m no

29.00 39.50 39.30

SJ331 SJ330 SJ325

592 593 594

100mm diameter. 150mm diameter. 200mm diameter. Extra over UPVC sewer pipe for fittings:

m m m

10.80 14.60 25.40

SJ390 SJ391 SJ392

595

100mm diameter bend (all angles).

no

6.30

SJ393

Page 71 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Extra over UPVC sewer pipe for fittings (Cont'd):

CODE

596 597 598 599 600

100mm diameter Y-junction. 150mm diameter bend (all angles). 150mm diameter Y-junction. 200mm diameter bend (all angles). 200mm diameter Y-junction. UPVC pipe Class D for soil, waste, ventilation, discharge stacks and down pipes fixed to wall or ceiling with collar brackets :

no no no no no

14.60 10.70 23.60 59.20 40.20

SJ394 SJ395 SJ396 SJ397 SJ398

601 602 603

80mm diameter. 100mm diameter. 150mm diameter. UPVC pipe for soil, waste,ventilation, discharge stacks and down pipes fixed to wall or ceiling with collar brackets :

m m m

16.40 19.80 35.70

SJ428 SJ399 SJ400

604 605 606 607 608

32mm diameter. 50mm diameter. 80mm diameter. 100mm diameter. 150mm diameter. Extra over UPVC soil, waste, ventilation, discharge stacks and down pipes for fittings:

m m m m m

7.00 8.00 11.90 14.90 22.60

SJ401 SJ402 SJ403 SJ404 SJ405

609 610

32mm diameter bend (all angles). 50mm diameter bend (all angles) - with doublelocking device. 80mm diameter bend (all angles) - with doublelocking device. 80mm x 50mm diameter junction.

no no

4.90 5.80

SJ406 SJ407

611

no

9.90

SJ408

612

no

12.20

SJ409

Page 72 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Extra over UPVC soil, waste, ventilation, discharge stacks and down pipes for fittings (cont'd) :

CODE

613

100mm diameter bend (all angles) - with doublelocking device. 100mm diameter single junction - with double-locking device. 100mm diameter double junction. 100mm x 50mm diameter single junction - with doublelocking device. 100mm x 50mm diameter double junction - with double-locking device. 100mm x 80mm diameter single junction. 100mm x 80mm diameter double junction. 150mm diameter bend (all angles). 150mm diameter single junction. UPVC fittings for soil, waste, ventilation, discharge stacks and down pipes :

no

11.30

SJ410

614

no

18.20

SJ411

615 616

no no

19.70 21.70

SJ412 SJ413

617

no

31.70

SJ414

618 619 620 621

no no no no

11.80 21.40 12.20 25.90

SJ415 SJ416 SJ417 SJ418

622 623 624

80mm diameter adaptor. 100mm diameter adaptor. 150mm diameter adaptor. Extra over UPVC soil, waste, ventilation, discharge stacks and down pipes for fittings Class D :

no no no

9.20 11.00 11.60

SJ422 SJ423 SJ424

625 626

100mm x 80mm diameter level invert taper. 150mm x 100mm diameter level invert taper. UPVC end cap to waste pipe :

no no

7.60 10.90

SJ425 SJ426

627 628 629

50mm diameter. 100mm diameter. 150mm diameter.

no no no

3.40 4.60 6.00

SJ296 SJ295 SJ294

Page 73 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D UPVC waste outlet to 50mm diameter waste pipe comprising of 110 x 110mm square base including jointing to pipe and setting on concrete floor:

CODE

630 631

With dome-shaped screw-in grating cover. With flat round screw-in grating cover. UPVC downspout outlet with dome-shaped screw-in grating complete with all necessary accessories and setting in cement mortar as specified:

no no

9.00 5.70

SJ271 SJ333

632

With 150 x 150mm square base to 80mm diameter pipe. With 200 x 200mm square base to 100mm diameter pipe. 150mm diameter UPVC gully trap complete with hopper and 150 x 150mm UPVC grating with screw-in round grating cover and filter including jointing to waste pipe and encasing in concrete. 100mm diameter UPVC floor waste complete with hopper and 150 x 150mm UPVC grating with screw-in round grating cover and filter including jointing to waste pipe and encasing in concrete. Anti-mosquito device to floor and gully traps as specified.

no

13.20

SJ231

633

no

16.50

SJ232

634

no

80.30

SJ265

635

no

52.20

SJ268

636

no

2.70

SJ368

Page 74 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D 100mm diameter UPVC floor trap complete with 150 x 150mm UPVC hinged grating with round grating cover including jointing to waste pipe:

CODE

637 638

'S' trap - with double-locking device. 'P' trap - with double-locking device. UPVC socket sleeve to reinforced concrete floor opening:

no no

54.20 42.30

SJ264 SJ349

639 640 641

100mm diameter. 80mm diameter. 50mm diameter. UPVC vent cowl to top of pipe as specified:

no no no

5.80 9.60 3.00

SJ344 SJ507 SJ346

642 643

100mm diameter. 150mm diameter. Ductile iron pipe with cement lining laid on concrete bed in trench (trench and concrete bed measured separately):

no no

2.80 5.20

SJ229 SJ230

644 645 646

80mm diameter. 100mm diameter. 150mm diameter. Extra over ductile iron pipe for:

m m m

44.30 41.60 54.00

SJ033 SJ034 SJ035

647 648 649

80mm diameter bend (all angles). 100mm diameter bend (all angles). 150mm diameter bend (all angles).

no no no

16.10 38.10 66.00

SJ036 SJ037 SJ038

Page 75 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D

CODE

650

80mm diameter stainless steel washout connecting pipe 350mm long with stainless steel flange at one end and welded with and including 150mm diameter x 9mm thick stainless steel collar at mid-length and cast in reinforced concrete structure. 28mm diameter stainless steel overflow warning connecting pipe 400mm long welded with and including stainless steel collar at mid-length and cast in reinforced concrete structure. 15mm diameter stainless steel flexible connecting pipe 400mm long welded with and including stainless steel collar at mid-length and cast in reinforced concrete structure. Grade 30 concrete bed and haunching to drain pipe complete with 40mm thick lean concrete and all necessary formwork (drain pipes measured separately):

set

347.10

SJ027

651

set

93.30

SJ028

652

set

7.70

SJ261

653

400mm wide x overall 400mm thick to 100mm diameter pipe reinforced with A10 WSF reinforcement. 400mm wide x overall 400mm thick to 100mm diameter pipe reinforced with B10 WSF reinforcement. 400mm wide x overall 400mm thick to 100mm diameter pipe reinforced with B10 WSF reinforcement and 2 nos T13 reinforcement bars. 450mm wide x overall 450mm thick to 150mm diameter pipe reinforced with A10 WSF reinforcement. 450mm wide x overall 450mm thick to 150mm diameter pipe reinforced with B10 WSF reinforcement. 450mm wide x overall 450mm thick to 150mm diameter pipe reinforced with B10 WSF reinforcement and 2 nos T13 reinforcement bars. 500mm wide x overall 500mm thick to 200mm diameter pipe reinforced with A10 WSF reinforcement.

43.40

SJ347

654

44.60

SJ334

655

48.60

SJ029

656

50.90

SJ348

657

52.30

SJ335

658

56.30

SJ030

659

58.60

SJ386

Page 76 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Reinforced Concrete Grade 30 inspection chamber/sump comprising of 150mm thick walls and bottom slab, 200mm thick top slab including necessary reinforcement and formwork complete with granolithic concrete benching, half round vitrified clay main and branch channels, cement plastering to internal walls, lean concrete base and excavation (inspection chamber/sump cover and frame measured separately):

CODE

660 661 662 663 664 665 666 667 668 669 670 671 672 673

Overall size 1200 x 1000 x 1070mm deep to invert. Add to last item for each additional 150mm depth. Overall size 1500 x 1000 x 1070mm deep to invert. Add to last item for each additional 150mm depth. Overall size 1800 x 1000 x 1070mm deep to invert. Add to last item for each additional 150mm depth. Overall size 2100 x 1000 x 1070mm deep to invert. Add to last item for each additional 150mm depth. Overall size 1650 x 1650 x 1070mm deep to invert. Add to last item for each additional 150mm depth. Overall size 900 x 900 x 600mm deep to invert. Add to last item for each additional 150mm depth. Overall size 1200 x 1000 x 750mm deep to invert. Add to last item for each additional 150mm depth.

no no no no no no no no no no no no no no

755.00 73.70 866.60 84.80 992.60 95.90 1,172.90 107.10 1,310.50 115.60 356.90 40.70 563.80 73.70

SJ298 SJ299 SJ300 SJ301 SJ302 SJ303 SJ304 SJ305 SJ306 SJ307 SJ308 SJ309 SJ310 SJ311

Page 77 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D

CODE

674

Precast concrete inspection chamber size 900x700(internal)x1070mm deep to invert complete with reinforcement, granolithic concrete benching, channels, cast-in-situ concrete topping and excavation (structural beam supports, inspection chamber cover and frame measured separately). Add to last item for each additional 150mm depth. Precast concrete inspection chamber size 1200x700(internal)x1070mm deep to invert complete with reinforcement, granolithic concrete benching, channels, cast-in-situ concrete topping and excavation (structural beam supports, inspection chamber cover and frame measured separately). Add to last item for each additional 150mm depth. Precast concrete encasement for 150mm diameter main drainline including concrete haunching and jointing (excavation, drain pipe and structural supports measured separately). 225mm thick (average) granolithic concrete (1:1:1) in benching and haunching to bottom of inspection chamber/sump finished to falls towards channels, including all necessary shaping of channels, bends etc as required. 100mm diameter half round vitrified clay straight or curve main or branch channels to inspection chamber/sump including bedding and jointing in cement mortar (1:1).

no

661.10

SJ502

675 676

no no

40.30 791.60

SJ503 SJ504

677 678

no m

45.90 131.30

SJ505 SJ506

679

41.60

SJ051

680

10.00

SJ054

681 682

150mm diameter ditto. 13mm thick cement and sand (1:2) rendering to internal/external surfaces of inspection chamber/sump. Light duty galvanised cast iron cover and frame size 600 x 450mm for inspection chamber/sump including setting frame in cement mortar and sealing cover in grease and fine sand. Standard cast iron street gulley including connection, all necessary excavation and concrete surround.

m m

12.50 10.40

SJ055 SJ056

683

no

62.90

SJ057

684

no

360.60

SJ046

Page 78 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Close-coupled dual flush low capacity vitreous china pedestal w.c. suite complete with w.c bowl, seat and cover and cistern with a flushing capacity of 4.5 litres per single action flush, including all necessary fittings and accessories:

CODE

685 686 687

White. Coloured. Squat w.c. pan in white vitreous china with brass cleaning eye, high level dual action plastic cistern complete with all necessary flush pipe, fittings and accessories.

no no no

238.70 268.80 175.10

SJ257 SJ281 SJ094

688

Squat w.c. pan in white vitreous china with brass cleaning eye, but without cistern and flush pipe. Wash-hand basin in coloured vitreous china size 500 x 400mm complete with waste plug and chain, approved non-corrosive brackets, UPVC waste pipe, bottle trap and all necessary washers, seals and nuts and fixed to wall all as specified. Wash-hand basin with pedestal stand in coloured vitreous china size 500 x 400mm complete with waste plug and chain, approved non- corrosive brackets, UPVC waste pipe, bottle trap and all necessary washers, seals and nuts and fixed to wall all as specified. Integral coloured cultured marble basin and top of approximate size 525 x 1500mm with 100mm backsplash, 200mm front apron complete with integrated basin, approved single lever mixer tap with pop-up waste, bottle trap, waste pipe and galvanised steel brackets for fixing to wall and all necessary accessories for fixing and jointing to pipework.

no

116.70

SJ095

689

no

92.80

SJ105

690

no

146.00

SJ501

691

no

663.40

SJ274

Page 79 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D

CODE

692

PUB approved stainless steel sensor operated flush valve complete with stainless steel outlet flush pipes to water closets including fixing and jointing to water supply and fittings as specified. PUB approved stainless steel sensor operated flush valve complete with stainless steel outlet flush pipes to urinals including fixing and jointing to water supply and fittings as specified. 15mm chromium plated brass pillar tap including all necessary accessories for fixing and jointing to pipeworks. 15mm chromium plated brass pillar tap with swivel swan neck including all necessary accessories for fixing and jointing to pipeworks. Delay action tap including all necessary accessories for fixing and jointing to pipeworks. 15mm chromium plated brass bib-tap including all necessary accessories for fixing and jointing to pipeworks. 15mm chromium plated brass 2-way bib-tap including all necessary accessories for fixing and jointing to pipeworks. 15mm chromium plated ceramic disc cartridge operated single lever basin mixer tap complete with pop-up waste including all necessary accessories for fixing and jointing to pipeworks. Chrome plated bath mixer tap with single lever control complete with adjustable jet shower head, 1.5m flexible shower hose and sliding bar and all necessary accessories as specified.

no

421.60

SJ286

693

no

394.00

SJ285

694

no

25.50

SJ106

695

no

63.30

SJ107

696

no

163.30

SJ109

697

no

23.70

SJ110

698

no

32.80

SJ290

699

no

71.90

SJ273

700

set

118.70

SJ361

Page 80 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Food-grade silicone thimble in natural colour with 4 nos holes each 2.5mm diameter:

CODE

701

Size 18.5mm diameter x 2.5mm thick at basin tap inlet. Size 21.0mm diameter x 2.5mm thick for tap mixer. 15mm diameter constant flow regulator of 12 litres per minute for bib tap inlet at common areas. Stainless steel water supply pipe including connectors, elbows, bends, tees, reducers, etc and laid in trench including excavation:

no

0.10

SJ350

702 703

no no

0.10 5.30

SJ351 SJ352

704 705 706 707 708

22mm diameter. 28mm diameter. 35mm diameter. 42mm diameter. 54mm diameter. Stainless steel water supply pipe including connectors, elbows, bends, tees, reducers, etc. and fixed to roof top with concrete supports:

m m m m m

18.90 22.00 28.00 33.40 55.50

SJ220 SJ221 SJ222 SJ223 SJ224

709 710 711 712 713

22mm diameter. 28mm diameter. 35mm diameter. 42mm diameter. 54mm diameter. Stainless steel water supply pipes including connectors, elbows, bends, tees, reducers, etc. and fixed to wall with stainless steel clips/holderbats:

m m m m m

12.20 15.30 20.70 26.10 48.10

SJ215 SJ216 SJ217 SJ218 SJ219

714 715

15mm diameter. 22mm diameter.

m m

11.70 15.20

SJ239 SJ129

Page 81 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Stainless steel water supply pipes including connectors, elbows, bends, tees, reducers, etc. and fixed to wall with stainless steel clips/holderbats (cont'd):

CODE

716 717 718 719

28mm diameter. 35mm diameter. 42mm diameter. 54mm diameter. Concealed copper pipes for cold/hot water supply complete with couplings, elbows, tees, etc fixed to walls, columns, beams including forming recesses, cutting grooves or chases in walls, columns etc and making good on completion as specified:

m m m m

19.30 26.50 32.90 57.20

SJ130 SJ131 SJ132 SJ225

720 721 722

15mm diameter. 22mm diameter. 28mm diameter. Compression fitting caps for copper pipes:

m m m

16.20 21.50 25.10

SJ362 SJ363 SJ364

723 724 725

15mm diameter. 22mm diameter. 28mm diameter. Ductile iron pipes with cement lining for water mains including spigot and socket joints, laid in trench including excavation:

no no no

3.20 3.70 7.10

SJ365 SJ366 SJ367

726 727

80mm diameter and backfilling with selected earth. 80mm diameter and backfilling with approved granular material. 100mm diameter and backfilling with selected earth. 100mm diameter and backfilling with approved granular material.

m m

52.40 89.60

SJ136 SJ369

728 729

m m

51.70 88.80

SJ137 SJ370

Page 82 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Ductile iron pipes with cement lining for water mains including flanged joints complete with bolts and nuts, laid on and including precast concrete support blocks:

CODE

730 731

80mm diameter. 100mm diameter. Ductile iron pipes with cement lining for water mains including spigot and socket joints fixed to wall with holderbats:

m m

57.00 55.00

SJ138 SJ139

732 733

80mm diameter. 100mm diameter. Extra over 80mm diameter ductile iron cement lined pipes for water mains for fittings including flanged joints complete with bolts and nuts:

m m

45.90 43.50

SJ140 SJ145

734 735 736 737

Bends. Tees. Collars. Socket adaptor. Extra over 100mm diameter ductile iron cement lined pipes for water mains for fittings including flanged joints complete with bolts and nuts:

no no no no

72.80 112.50 86.40 29.30

SJ141 SJ142 SJ143 SJ144

738 739 740 741 742

Bends. Tees. Collars. Duckfoot bend. 100mm diameter ductile iron flange adaptor for distribution main complete with rubber gaskets, bolts and nuts all as specified. Cast iron sluice/gate valve with flanged ends:

no no no no no

79.60 129.60 99.00 38.70 121.90

SJ146 SJ147 SJ148 SJ259 SJ318

743 744

80mm diameter. 100mm diameter.

no no

117.00 136.20

SJ151 SJ152

Page 83 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D

CODE

745

100mm diameter x 65mm ductile iron flanged flow nozzle.

no

115.80

SJ260

Bronze spring loaded lift check valve: 746 747 35mm diameter. 40mm diameter. Cast iron spring loaded lift check valve with flanged ends: 748 749 80mm diameter. 100mm diameter. Brass high pressure equilibrium ball valve with brass arm and copper float: 750 751 50mm diameter. 100mm diameter. Brass gate valve: 752 753 40mm diameter. 50mm diameter. Brass ball stop valve: 754 755 756 757 758 759 760 20mm diameter. 25mm diameter. 40mm diameter. 15mm diameter isolating ball stop valve 25mm diameter brass ball float valve. 35mm diameter brass globe valve. 40mm diameter solenoid valve for automatic timecontrolled refuse chute flashing system. Labour only for boring holes in UPVC pipes for approximately 3.2m long at 50mm centre/centre for use as bin chute sparge pipe. no no no no no no no 18.10 23.30 44.20 6.70 52.80 48.20 291.40 SJ210 SJ211 SJ212 SJ498 SJ262 SJ213 SJ214 no no 33.50 44.50 SJ208 SJ209 no no 478.20 1,267.50 SJ153 SJ154 no no 348.70 421.40 SJ206 SJ207 no no 24.20 33.00 SJ263 SJ205

761

no

9.40

SJ173

Page 84 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Brass high pressure screw down stop or bib cocks:

CODE

762 763 764 765 766 767 768

15mm diameter. 22mm diameter. 28mm diameter. 35mm diameter. 42mm diameter. 54mm diameter. 82mm diameter x 68mm high x 1.2mm thick purposemade galvanised steel casing as locking device for public tap. (padlock measured separately). Rolled steel joists for support to tanks including bolts, fixing and painting. 63mm diameter Polyethylene gas pipe sleeved in 80mm diameter UPVC pipe and laid in concrete channel including bituminous joints and filling up with cement mortar grout (concrete channel measured separately). 63mm diameter Polyethylene gas pipe sleeved in 80mm diameter UPVC pipe and laid in trench including excavation. 63mm x 50mm diameter galvanised steel Electrofusion Transition elbow to gas pipe. 80mm diameter UPVC pipe sleeve for vertical gas pipe fixed to wall. 'Viking Johnson Junor' coupling for 50mm diameter galvanised steel gas pipe including locking ring, gasket, etc. and all necessary accessories. Heavy duty galvanised steel gas pipe including sockets, connectors, elbows, tees, plugs, etc and fixed to wall or ceiling with collar brackets as specified:

no no no no no no no

12.20 20.00 37.00 78.40 97.10 139.80 7.60

SJ174 SJ175 SJ176 SJ177 SJ178 SJ179 SJ270

769

kg

1.30

SJ181

770

52.90

SJ491

771

29.70

SJ495

772

no

46.40

SJ493

773

11.70

SJ492

774

no

43.30

SJ494

775 776

40mm diameter. 50mm diameter.

m m

16.70 19.90

SJ186 SJ187

Page 85 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Full bore ball valve:

CODE

777 778 779 780 781 782 783

15mm diameter. 20mm diameter. 25mm diameter. 32mm diameter. 40mm diameter. 50mm diameter. 80mm diameter. Copper gas pipe including connectors, elbows, bends, tees, etc and fixed to wall:

no no no no no no no

14.80 17.40 21.70 24.60 28.80 38.40 130.90

SJ195 SJ196 SJ197 SJ198 SJ199 SJ200 SJ201

784 785 786

15mm diameter. 22mm diameter. UPVC Casing/Trunking for water and gas services including trunking cover with splayed edges, overall size 84 x 51mm as specified. Heavy duty galvanised steel pipe complying with API Standard 5L Grade B Schedule 40 with welded joints and fixed to wall or ceiling with pipe clips or mild steel brackets:

m m m

14.30 19.80 12.60

SJ202 SJ203 SJ228

787 788

40mm diameter. 50mm diameter. Class "C" galvanised steel pipes fixed to duct wall as dry, wet or hosereel rising main including all necessary brackets, connectors, welded flanges, bolts, nuts and gaskets, etc and testing the installation as specified:

m m

21.20 24.50

SJ272 SJ269

789 790 791

50mm diameter. 100mm diameter. 150mm diameter.

m m m

17.00 65.50 87.10

SJ357 SJ242 SJ243

Page 86 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D Class "C" galvanised steel pipes fixed to duct wall as dry, wet or hosereel rising main including all necessary brackets, connectors, welded flanges, bolts, nuts and gaskets, etc and testing the installation as specified (cont'd):

CODE

792 793 794 795

Extra over 50mm diameter pipe for bend or elbow. Extra over 50mm diameter pipe for tee. Extra over 100mm diameter pipe for bend. Extra over 150mm diameter pipe for bend. Rust proof electro galvanised steel box with glass front for breeching inlet complete with locks and master keys as specified (breeching inlet measured separately) :

no no no no

7.00 7.90 46.10 87.40

SJ496 SJ497 SJ244 SJ247

796 797

2-way. 4-way. Breeching inlet complete with 1 no. 25mm diameter drain valve including all necessary blank caps, chain, handwheel etc as specified:

no no

133.30 147.80

SJ250 SJ251

798 799 800

100mm diameter 2-way. 150mm diameter 4-way. Dry riser landing valve with instantaneous 63.5mm diameter female coupling complete with gunmetal bodies including necessary handwheel, blank caps, chains, mechanical tee connectors/adaptors, etc as specified. 25mm automatic air release valve as specified. Approved canvas/nylon belt with key-alike padlocks for strap locking handwheels in closed position.

no no no

184.70 313.80 125.00

SJ253 SJ254 SJ252

801 802

no no

26.50 6.30

SJ255 SJ256

Page 87 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) SANITARY, WATER AND GAS INSTALLATION (CONT'D 1.6mm thick electro-galvanised steel casing finished in baked red epoxy resin complete with all necessary accessories as specified for:

CODE

803 804 805 806

Fire hose-reel. 2.5 kg fire extinguisher. 4.5 kg fire extinguisher. Approved wall mounted double swivel and recessed type fire hose-reel complete with 30m long x 25mm diameter reinforced braided rubber hose, a jet or spray type shutoff nozzle, gun metal control valves, wall brackets and fittings including fixing to wall and painting.

no no no no

204.50 69.20 84.30 342.20

SJ292 SJ342 SJ359 SJ291

Dry powder portable fire extinguisher complete with horn, wall brackets and embossing extinguisher with 2 nos HDB logo as specified: 807 808 809 810 2.5 kg. 4.5 kg. 9 kg. 5kg CO2 portable fire extinguisher complete with horn, wall brackets and embossing extinguisher with 2 nos HDB logo as specified. no no no no 44.50 56.90 76.60 155.90 SJ338 SJ339 SJ340 SJ341

Page 88 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) GLAZING Sheet/float glass in panes:

CODE

811 812 813 814

4mm thick ordinary quality clear sheet/float glass. 5mm thick ditto. 6mm thick ditto. 5mm thick obscured glass. Tinted float glass in panes:

m m m m

25.90 31.60 35.00 40.30

SK001 SK002 SK003 SK004

815 816

5mm thick. 6mm thick. Clear tempered float glass in panes:

m m

44.30 48.20

SK005 SK006

817 818 819 820

6mm thick. 8mm thick. 10mm thick. 12mm thick. Tinted tempered float glass in panes:

m m m m

106.80 150.90 170.80 191.00

SK012 SK013 SK014 SK015

821 822 823 824

6mm thick. 8mm thick. 10mm thick. 12mm thick. Tinted laminated safety float glass in panes:

m m m m

123.30 168.20 182.70 205.20

SK016 SK017 SK018 SK019

825 826

10.38mm thick. 12.76mm thick.

m m

122.70 170.80

SK020 SK021

Page 89 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) GLAZING (CONT'D) Glass in louvres - varying from 100mm to 200mm wide:

CODE

827 828 829 830

5mm thick ordinary clear sheet/float glass. 6mm thick ditto. 5mm thick obscured wired glass. 6mm thick rough cast obscured wired glass.

m m m m

31.10 35.00 40.50 47.40

SK008 SK009 SK010 SK011

Page 90 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) PAINTING AND DECORATING Concrete or Plastered Surfaces

CODE

831

One coat of approved acrylic emulsion paint (with 20% water dilution). One priming coat (with 20% water dilution) and two upper coats (without water dilution) of approved acrylic synthetic emulsion paint. One priming coat (with 20% water dilution) and one upper coat (without water dilution) of approved acrylic synthetic emulsion paint by spraying equipment, paint roller or other means including protecting door/window frames, or other surfaces from being tainted with paint. One coat of water based sealer and two subsequent coats of approved water based Algae Resistant Emulsion Paint (all coats without dilution) Rate inclusive of the provision of a 6 year warranty. One coat of water based sealer. Metal Surfaces

1.40

SL002

832

3.50

SL003

833

2.50

SL037

834

4.80

SL041

835

1.50

SL008

836 837 838

One coat of approved lead and chromate-free primer. One coat of polyvinyl butyral etching primer. One undercoat and one finishing coat of approved synthetic enamel paint. One undercoat and one finishing coat of approved synthetic enamel paint on grilles or railing etc (rate inclusive of painting on both faces). Two coats of approved synthetic enamel paint to mild steel sections or door frame not exceeding 300mm girth. Surface treatment to structural steelwork with one coat of zinc-rich epoxy primer and two coats of zinc phosphate priming paint including blast cleaning at workshop.

m m

3.50 2.60 4.50

SL038 SL039 SL009

839

5.20

SL010

840

1.60

SL018

841

42.30

SL040

Page 91 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) PAINTING AND DECORATING (CONT'D) Pipe Surfaces One coat of approved lead and chromate-free primer:

CODE

842 843

not exceeding 75mm diameter. exceeding 75mm but not exceeding 150mm diameter.

m m

0.90 1.70

SL012 SL013

844

exceeding 150mm but not exceeding 300mm diameter. Two coats of approved lead and chromate-free primer:

3.40

SL014

845

exceeding 75mm but not exceeding 150mm diameter.

3.10

SL023

One coat of polyvinyl butyral etching primer: 846 847 not exceeding 75mm diameter. exceeding 75mm but not exceeding 150mm diameter. m m 0.70 1.30 SL030 SL031

848

exceeding 150mm but not exceeding 300mm diameter. Two coats of approved synthetic enamel paint:

2.60

SL032

849 850

not exceeding 75mm diameter. exceeding 75mm but not exceeding 150mm diameter.

m m

1.20 2.30

SL015 SL016

851

exceeding 150mm but not exceeding 300mm diameter.

4.50

SL017

Page 92 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) PAINTING AND DECORATING (CONT'D) Timber Surfaces

CODE

852

One coat wood primer and two coats of approved synthetic enamel paint. Two coats of wood stain/wood dye and three coats of clear varnish/lacquer in matt or gloss finish. Two coats of wood preservative. Two coats of polyurethane varnish.

7.40

SL019

853

11.30

SL036

854 855

m m

2.40 5.70

SL020 SL022

Page 93 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) TURFING, TREE PLANTING & LANDSCAPING WORKS

CODE

856

225x225mm spot turfing (with 25mm thick original top soil) at 450mm centre both directions with a layer of approved soil mixture 125mm thick including the maintenance of the turfing works during the "Maintenance Period" as specified. Strip turfing (with 25mm thick original top soil) 450mm wide and spaced 600mm between strips at an angle of 45 degree on embankments with a layer of approved soil mixture 125mm thick including the maintenance of the turfing works during the "Maintenance Period" as specified. Close turfing (with 25mm thick original top soil) with a layer of approved soil mixture 125mm thick including the maintenance of the turfing works during the "Maintenance Period" as specified:

6.50

SM002

857

9.90

SM004

858 859 860

To slope embankment. To flat level surface. Excavate trench to form shrub/flower bed, including backfilling to level about 250mm above the adjacent ground level with approved soil mixture as specified (plants measured separately). Excavate tree hole including backfill to a level 250mm above ground with approved soil mixture as specified (tree measured separately):

m m m

12.30 11.50 43.40

SM009 SM011 SM018

861 862 863

1.50 x 1.50 x 1.00m deep. 1.00 x 1.00 x 1.00m deep. 0.50 x 0.50 x 0.50m deep. Planting of instant tree including maintenance as specified (tree measured separately):

no no no

99.60 44.30 6.30

SM078 SM077 SM079

864 865

Not exceeding 300mm girth. Exceeding 300mm but not exceeding 500mm girth.

no no

3.60 4.80

SM080 SM081

Page 94 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) TURFING, TREE PLANTING & LANDSCAPING WORKS (CONT'D) Planting of tree saplings/fruit trees/palms including maintenance as specified (tree measured separately):

CODE

866 867 868 869

Large size with minimun height 2.00m. Medium size with minimun height 1.50m. Small size with minimun height 1.00m. Planting of shrubs of any size including maintenance as specified (shrub measured separately). Cut down trees with girth measured at a point 1.0m above the ground, grub up roots and clear away from site:

no no no no

3.00 2.40 1.80 0.83

SM082 SM083 SM084 SM085

870 871 872 873 874 875 876 877 878 879

Not exceeding 0.5m girth. Exceeding 0.5m but not exceeding 1.0m girth. Exceeding 1.0m but not exceeding 1.5m girth. Exceeding 1.5m but not exceeding 2.0m girth. Exceeding 2.0m but not exceeding 2.5m girth. Exceeding 2.5m but not exceeding 3.0m girth. Exceeding 3.0m but not exceeding 4.0m girth. Exceeding 4.0m but not exceeding 5.0m girth. Exceeding 5.0m but not exceeding 6.0m girth. Bintangore pole as supporting stake to tree including ties as specified. Tripod support with 3 nos. of bintangore poles including ties and gunny sack as specified. Tree guard with 4 nos. bintangore poles 1.50m above ground and tied together with galvanised wire bracing as specified. Tree guard with 4 nos. bintangore poles 0.30m above ground and tied together with galvanised wire bracing as specified.

no no no no no no no no no m

193.80 237.50 313.90 467.80 592.60 773.30 949.40 1,209.20 1,446.30 1.40

SM066 SM067 SM068 SM069 SM070 SM071 SM072 SM073 SM074 SM039

880

no

12.60

SM040

881

no

20.90

SM041

882

no

8.40

SM042

Page 95 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) TURFING, TREE PLANTING & LANDSCAPING WORKS (CONT'D) Approved perforated UPVC sub-soil pipe with open end butt joints:

CODE

883 884 885

100mm diameter. 150mm diameter. 150mm diameter wrapped round with geotextile fabric (non-woven type). 19 to 25mm coarse aggregate wrapped round with ordinary grade geotextile fabric (non-woven type) to perforated UPVC pipe including all necessary excavation (pipe measured separately). 50mm diameter UPVC pipe as weephole not exceeding 300mm long. Supply, fix and subsequent removal of temporary barricade fencing consisting of 50 x 50 x 1650mm long balau timber post spaced at 2400mm centre to centre, pointed at bottom and driven 450mm deep into the ground and with 10mm diameter nylon ropes running horizontally and diagonally across the top and bottom of barricade including extra timber strutting at corner and end post as specified. Approved green nylon netting:

m m m

8.40 12.00 13.40

SM014 SM013 SM076

886

70.60

SM065

887

no

2.10

SM075

888

4.30

SM015

889 890

Single layer. Double layer.

m m

1.40 2.70

SM043 SM044

Page 96 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) MISCELLANEOUS

CODE

891

Design, erection and subsequent removal of protective hoarding with overhead shelter average 4.5m high and 1.70m wide with timber supports, metal sheet hoarding and timber floor boarding as shown in drawings. Natural anodised aluminium extruded framed notice board, size 1200 x 900mm high, constructed of 2mm thick aluminium casing, complete with 1 no. aluminium frame door infilled with 5mm thick clear polycarbonate sheet, hinges, lockset, 12.7mm thick softboard with velvet fabric finish, 9mm thick plywood, complete with fluorescent tube and wiring as specified. 200 x 50mm Electro-Galvanised Steel Trunking with removable cover for telephone cables fixed to wall or ceiling complete with slotted brackets and fixing accessories as specified. 200 x 75mm Electro-Galvanised Steel Trunking with removable cover for telephone cables fixed to wall or ceiling complete with slotted brackets and fixing accessories as specified. 155mm diameter Class `B' UPVC pipe for underground LT reticulation cables with concrete haunching and necessary fabric reinforcement at pipe joints including the provision of a nylon/polyethelane rope and testing of pipe on completion (Excavation and sand bed measured separately). Extra over 155mm diameter UPVC pipe for Grade 20 concrete haunching throughout including all necessary formwork and A6 WSF reinforcement (Excavation measured separately). UPVC plugs at pipe mouth of 155mm diameter UPVC pipe in draw pits. 110mm diameter UPVC lead-in pipe in trench including end cap (Trench measured separately). 172.4mm wide (nominal) x 2mm thick high impact UPVC cable cover plates with embossed letterings as specified.

385.40

SM064

892

no

384.70

SM034

893

20.70

SM035

894

21.90

SM036

895

17.90

SM050

896

6.40

SM051

897

no

7.90

SM058

898

5.90

SM063

899

3.00

SM052

Page 97 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) MISCELLANEOUS (CONT'D) Drawpits for underground LT reticulation cables comprising of 100mm thick `L' shaped pc slabs as walls, 100mm thick concrete base reinforced with A6 WSF reinforcement, the pit filled with sand bags and covered with 450x450x75mm thick precast concrete top cover slabs with UPVC plates for various shapes and types as specified (measured flat on plan excavation measured separately):

CODE

900 901 902 903 904 905 906

Rectangular shaped. `T' shaped. `Y' shaped. `X' shaped. `L' shaped. `R' shaped. Vertical drawpit marker comprising of 75mm diameter heavy duty UPVC conduit pipe with purpose made capping cover as specified. StarHub Telecommunication Cable Pipes and Manholes 110mm diameter UPVC pipes in trench including excavation and backfilling and completely surrounding pipe with grade 20 concrete bed and haunching and all necessary formwork :

m m m m m m no

164.70 132.20 133.70 127.80 134.70 143.00 31.50

SM053 SM054 SM055 SM056 SM057 SM062 SM059

907

1-way with concrete bed and haunching, 210mm wide x overall 210mm thick. 2-way with concrete bed and haunching, 346mm wide x overall 210mm thick. 3-way with concrete bed and haunching, 346mm wide x overall 346mm thick. 4-way with concrete bed and haunching, 346mm wide x overall 346mm thick. 6-way with concrete bed and haunching, 481mm wide x overall 346mm thick.

27.40

SJ371

908

42.90

SJ372

909

58.30

SJ373

910

62.80

SJ374

911

84.30

SJ375

Page 98 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) MISCELLANEOUS (CONT'D) StarHub Telecommunication Cable Pipes and Manholes (Cont'd) 110mm diameter UPVC pipes in trench including excavation and backfilling and completely surrounding pipe with grade 20 concrete bed and haunching and all necessary formwork (cont'd):

CODE

912

9-way with concrete bed and haunching, 481mm wide x overall 481mm thick. 12-way with concrete bed and haunching, 617mm wide x overall 481mm thick. Reinforced concrete grade 30 manhole including necessary reinforcement and formwork with 20mm thick screeding trowelled smooth to fall at base, lean concrete, excavation, hardcore and the installation of channel bracket and anchor iron (cover and frame measured separately):

110.20

SJ376

913

139.50

SJ377

914

Type JX2 comprising of 120mm thick walls and bottom slab. Type MX1 comprising of 150mm thick walls and bottom slab. Type MX2 comprising of 150mm thick walls and bottom slab. Type MX3 comprising of 230mm thick walls and bottom slab. Type MX4 comprising of 230mm thick walls and bottom slab. 78mm thick grade 30 concrete top slab overall size approximately 1316 x 1202mm inclusive of the collection of manhole frame and cover from StarHub's warehouse and setting frame in cement mortar and sealing cover in grease and sand (manhole cover and frame supplied by StarHub).

no

301.70

SJ378

915

no

1,116.00

SJ379

916

no

1,375.60

SJ380

917

no

2,658.90

SJ381

918

no

3,229.30

SJ382

919

no

56.80

SJ499

Page 99 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) DAYWORK Rates for the following items do not include establishment charges and profit:

CODE

920 921 922 923 924 925 926 927 928 929 930 931 932 933 934 935 936 937 938 939 940 941

Bricklayer. Blocklayer. Carpenter. Concretor. Construction Equipment Operator. Crane Driver. Drainlayer. Excavator. Fitter. Glazier. Ironmonger. Joiner. Labourer. Lorry Driver. Mason. Mechanic. Painter. Pavior. Piler. Plasterer. Plumber. Roller Driver.

hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr hr

9.10 9.10 9.70 9.50 13.30 12.80 9.40 8.50 9.50 9.60 9.90 9.80 7.40 9.30 9.10 10.00 8.30 9.30 10.30 10.40 11.00 13.30

SN001 SN002 SN003 SN004 SN019 SN005 SN006 SN007 SN008 SN009 SN010 SN011 SN012 SN013 SN014 SN015 SN016 SN017 SN018 SN020 SN021 SN022

Page 100 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) DAYWORK (CONT'D) Rates for the following items do not include establishment charges and profit (Cont'd):

CODE

942 943 944 945 946 947 948 949 950 951

Roofer. Scaffolder. Steel Bender & Fixer. Steel Worker. Tiler. Tractor Driver. Watchman. Welder. Wireman. Air compressor with air delivery capacity not less than 4.5 cu m per minute including pneumatic and sharpening tools and power supply (operator measured separately). Concrete mixer 200/140 litres including fuel. Concrete mixer 300/200 litres including fuel. Crane (KATO KR20H) including fuel and driver. Diesel powered field welding machine with minimum 300 amp. Mechanical lawn mover with blade not exceeding 500mm and engine power not exceeding 150 cc. Motor crane including fuel and driver (3 tonne lifting capacity). Motor Crane including fuel and driver (8-13 tonne lifting capacity). Motor lorry 2.5 - 3 tonne size including fuel and driver.

hr hr hr hr hr hr hr hr hr hr

9.70 9.70 9.60 8.90 10.50 13.30 7.30 9.80 10.90 23.45

SN023 SN024 SN025 SN026 SN027 SN028 SN029 SN030 SN031 SN032

952 953 954 955

hr hr hr hr

14.70 21.55 111.30 14.50

SN033 SN034 SN050 SN036

956

hr

2.50

SN037

957

hr

39.90

SN038

958

hr

74.48

SN051

959

hr

28.35

SN039

Page 101 of 101

S/N

HOUSING AND DEVELOPMENT BOARD STANDARD SCHEDULE OF RATES FOR BUILDING WORKS (JUL 2011) DESCRIPTION UNIT RATE($) DAYWORK (CONT'D) Rates for the following items do not include establishment charges and profit (Cont'd):

CODE

960

Motor lorry 5.5 - 7 tonne size including fuel and driver.

hr

44.09

SN040

961 962

Motor lorry 10 tonne size including fuel and driver. Power driven pump 50mm size including fuel and driver. Power driven pump 75mm size including fuel and driver. Power loader on rubber-tyred wheels 1.20 cu m bucket capacity (flywheel horsepower 60 kw range) including fuel and driver. Road roller 6 tonne capacity including fuel and driver.

hr hr

54.60 19.48

SN052 SN041

963

hr

25.17

SN042

964

hr

65.65

SN043

965

hr

34.15

SN044

966

Road roller 8 to 10 tonne capacity including fuel and driver. Traxacavator 1.0 cu m capacity including fuel and driver. Traxacavator 1.5 cu m capacity including fuel and driver. Traxacavator 2.0 cu m capacity including fuel and driver. Wheel or crawler shovel or excavator loaders with back hoe bucket not exceeding 0.4 cu m or 1.3 cu m loader bucket capacity including fuel and driver.

hr

40.09

SN045

967

hr

81.60

SN046

968

hr

89.25

SN047

969

hr

110.25

SN048

970

hr

78.75

SN049

You might also like