You are on page 1of 5

Ourhighlyprefabricatedelementsystemforexteriorwallsspeedsuponsiteconstruction.

TheprefabricatedelementsincludeanenergyefficientTermostudframeandaninsulationcore,bothmadeofnoncombustiblematerial.
Externalcladdingelementcanbeanythingfrommetalthroughwood,glasstonaturalstone,brickorceramictiles.Flexibilityinthenumberand
sizeorshapeofwindowsanddoors,coupledwithseveralcladdingalternativesgivesalmostunlimitedoptionsforafaadeappealing
appearance.
CEmarking:AccordingEN13830

Applications:
l Externalwallsinofficeandcommercialbuildings
l Externalwallsinpublicandindustrialbuildings
l Externalwallsinresidentialbuildings

Squareelement: max.3600x10500mm
Stripelement: max.600x10500mm
Horizontalframeelement: max.3600x10500mm
Commercialbuildings:
Squareelementsystem Stripelementsystem

Blockofflats:


1.Externalfacadeoptions
l Steelorothermetals
l Wood
l Glass
l Naturalstone,brickorclaytile
l Ventilatedthinrendering
l Insulatedrendering
l Ceramictiles
2.Ventilationchannel20mm
l Purlins,e.g.SupportstudCA1SS
3.WindshieldBoardOptions
l Gypsumsheathingboard,9mm
l Porouswoodfibresheathingboard,e.g.12mmor25mm
l Plywood,e.g.6,5mmor9mm
l Bitulite,e.g.12mm
l Cementbondedparticleboard,4mmor8mm.
4.Thermalinsulation/termostud
l Thermalinsulationisnoncombustible
l DesignthermalconductivityDesign=0.034/0.035W/mK
l Windshieldboardpaneljointsaresealedandbothsidesoftheinsulationareincontactwithinsulatedsurfaces
l TermostudmaterialS350GD+Z
l LPATU,Ushapedtermostud
l LPATC,Cshapedtermostud
l LPATUW,Ushapedtermostudwithwideflanges
5.Vapourbarrier
l LDPEpolyethylene0,2mm,SFS4225,EclassUVprotected
l WatervapourpermeabilityvalueWp=0,002*109kg/(m
2
sPa)

l WatervapourdiffusionresistanceZp=500*109m
2
sPa/kg

6.InternalLiningOptions
l Hardenedgypsumboard,13mm(EK13)
l Thinsteelsheet0,61,0mm+hardenedgypsumboard13mm
l Woodgypsumboard,e.g.10mmor12mm
l Chipboard,e.g.10mm,11mmor12mm
l Plywood,e.g.9mmor12mm
l Semihardwoodfibreboard,e.g.9mm
l Thinsteelsheet1,5mm


WallelementUvalues8rowperforation
WallelementUvalues10rowperforation,insulation(W/mK)0.034RockwoolfireEI60
WallelementUvalues10rowperforation,insulation(W/mK)0.033GlasswoolfireEI
UvaluesbystandardISOEN6946:2007andEN10211:2007.
Widthofthermalstud(mm) Thicknessofsteel(mm) Perforation Insulation(W/mK)
Uvalue(W/m
2
K)
175 1.0 8rows 0.035 0.22
175 1.2 8rows 0.035 0.23
175 1.5 8rows 0.035 0.23
175 2.0 8rows 0.035 0.24
200 1.0 8rows 0.035 0.20
200 1.2 8rows 0.035 0.21
200 1.5 8rows 0.035 0.21
200 2.0 8rows 0.035 0.22
Widthofthermalstud(mm) Thicknessofpurlins(mm) Perforation
Insulation(W/mK)
1)
Uvalue(W/m
2
K)
225 1.0 10rows 0.034 0.18
225 1.2 10rows 0.034 0.18
225 1.5 10rows 0.034 0.19
225 2.0 10rows 0.034 0.19
250 1.0 10rows 0.034 0.17
250 1.2 10rows 0.034 0.17
250 1.5 10rows 0.034 0.17
250 2.0 10rows 0.034 0.18
275 1.2 10rows 0.034 0.16
275 1.5 10rows 0.034 0.17
275 2.0 10rows 0.034 0.17
Widthofthermalstud(mm) Thicknessofpurlins(mm) Perforation
Insulation(W/mK)
1)
Uvalue(W/m
2
K)
225 1.0 10rows 0.033 0.17
225 1.2 10rows 0.033 0.18
225 1.5 10rows 0.033 0.18
225 2.0 10rows 0.033 0.19
250 1.0 10rows 0.033 0.16
250 1.2 10rows 0.033 0.17
250 1.5 10rows 0.033 0.17
250 2.0 10rows 0.033 0.18
275 1.2 10rows 0.033 0.16
275 1.5 10rows 0.033 0.16
275 2.0 10rows 0.033 0.17

*Calculatedvalue
Rw(dB):Airbornesoundinsulationvalue
R
A,tr
(=RW+Ctr)(dB):Trafficnoisesoundinsulationvalue
Teststandard: ENISO1403:1995
Classificationstandard: ENISO7171:1996
Structuresfrominsideoutwards:
Rw(dB) C
tr,1003150
(dB) R
A,tr
(=Rw+C
tr
)(dB)
Studdepth225mm:
EK13+LPTC225+TS9 54 7 47
Studdepth175mm:
EK13+LPTC175+TS9 51 9 42
EK13+0,6thinsteelsheet+LPTC175+TS9 54 9 45
EK13+LPTC175+TS9+purlins+corrugatedsheet 50 7 43
2xEK13+LPTC175+TS9+purlins+corrugatedsheet 51 6 45
EK13+LPTC175+TS9+verticalpurlins+horizontalcladding 49 6 43
EK13+LPTC175+TS9+purlins/additionalinsulation+corrugatedsheet 52 9 43
EK13+LPTC175+TS9thermalinsulation+50mm+8mmrendering 54 7 47
EK13+LPTC175+TS9+30mmventilationcavity+tilecladding85mm 61 5 56
EK13+LPTC175+TS9+horizontalpurlins20mm+Aquapanel12.5+8mmrendering* 51 10 41
EK13+LPTC175+TS9+horizontalpurlins45mm+Aquapanel12.5+8mmrendering* 55 11 44
Studdepth125mm:
EK13+LPTC125+TS9 50 8 42

InloadbearingwallsituationsstructurescanalsomeetREI30andREI60inaccordancewithseparateinstructions.
R=resistance,E=integrity,I=insulation
Infirestructures,rockwoolshouldbeusedasthermalinsulation,e.g.ParoceXtra.
Teststandard: EN13631,EN13651
Classificationstandard: EN135012
Facadestructuresfrominsideoutwards: Fireclass
EK13+LPTC175+TS9 EI60