Professional Documents
Culture Documents
IMPORTANT NOTES: In order to successfully install Autodesk and Bentley applications you must
be logged in as the local User, with local Administrator rights. Further, to install Bentley AutoPLANT V8i (SELECTseries 1) successfully, AutoCAD 2007 SP2 must first be installed and launched at least once to create the default AutoCAD 2007 profile.
Once you have successfully installed the applications as above, install the Praxair customizations as detailed in the following pages.
3. After successfully installing the Praxair BASE Customizations, set the Drawing Flattener Settings by running the Registry Entries file: 02_PX-PTC_CUST_appd08110630en_v1.0h_Drawing_Flattener.reg 4. For regional installs, run the appropriate executable from the list below: For Belgium: For Brazil: For Canada: For China: For India: For Mexico: 03_PX-BEL_CUST_appd08110630en_v1.0h.exe 03_PX-BRA_CUST_appd08110630en_v1.0h.exe 03_PX-CAN_CUST_appd08110630en_v1.0h.exe 03_PX-CHN_CUST_appd08110630en_v1.0h.exe 03_PX-IND_CUST_appd08110630en_v1.0h.exe 03_PX-MEX_CUST_appd08110630en_v1.0h.exe
At the welcome screen that appears (as below), click Next >.
5. Installation is now complete. For detailed information on project administrator procedures and standards, please see the following documents: 01 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - New Project Creation 02 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Project Administration - Creating Project Specific VISION Startup Icons 03 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - File Naming Convention and Reference Model Hierarchy 04a - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation Using Bentley Vision V8i (SELECTseries 1) 04b - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - New Document Creation Using ProjectWise Explorer V8i (SELECTseries 1) 05 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - Work Area Setup 06 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production - Drawing Flattener 07 - Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Praxair AutoCAD Color Table
From the docked browser tree structure select Supports > Base Supports.
Two custom support sections are available. I. II. Praxair Supports - Cold Box Praxair Supports - Warmend
Double-click on PSD-01 U-Bolt Support - Loose (guide). You will be prompted to select the piping component on which you wish to place the support. Select T to toggle the port you wish to start from then Enter to make the selection. Enter the distance from the port at which you wish to place the support.
Chapter 1
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) Project Administration - New Project Creation
Initial Project Creation
New projects can be created in two ways: Distributed Mode: This is a MS Access MDB project database, with individual model MDB files. Distributed mode is intended for small/medium sized projects (only recommended for local C:\ drive temporary project environments) where the user wants to continue to run MS Access for the primary database while retaining the benefits of a managed project. (See page 6 of this chapter) Central Mode: All data is stored in central project database. It requires a SQL Server database to be created. All Praxair projects are to be created in this mode. (See page 11 of this chapter)
Getting Started
The first step in setting up a project is to create the Local Projects Root folder. This folder is the top level directory under which individual projects related to the root will reside. You will have more than one Local Projects Root folder with multiple projects defined under each.
Would be: \PLANT\Projects\CAN138-Varennes, QB\... More Examples: \PLANT\Projects\BRACOS-Cosipa, Brazil\... \PLANT\Projects\CHNCAO-Caojing, China\... \PLANT\Projects\DEUHEU-Huerth, Germany\... \PLANT\Projects\MEXTAM-Tampico, Mexico\... \PLANT\Projects\USA360-Hawkins, TX\... \PLANT\Projects\USA978-Riverport, TN\...
The next level will be: \PLANT\Projects\SITE_ID\PLANT_TYPE\ PROJ_NAME \... Where: PLANT_TYPE refers to the type of plant at the site. Example: \PLANT\Projects\CAN044-Montreal_East_QB\ TLA_480\... \PLANT\Projects\CAN138-Varennes_QB\300_MTON\... \PLANT\Projects\USA357-Texas_City_2\T-1800\... \PLANT\Projects\ USA978-Riverport, TN \ PL3XL \... This folder will act as the Local Projects Root folder. When initially set up as a root using Project Administrator it will contain the following root files: Access.mdb at_prods.dbf at_proj.dbf This file controls Bentley login access/permissions to the projects in the root. This file contains REGAPP mappings for Bentley Vision. This file logs the PROJ_ID contained in this root (0001, 0002, 0003)
Note: If the site has multiple identical plant types such as two PL4s then the root will have to be adjusted to be unique. PL4_1 and PL4_2, etc Further: If there are both 2D PID projects and 3D PIPING projects at the plant then the roots are to be adjusted as follows: PL4_2D and PL4_3D, etc The last level will be: \PLANT\Projects\SITE_ID\PLANT_TYPE\ PROJ_NAME \... Where: PROJ_NAME is actually the project number. Example: \PLANT\Projects\ CAN044-Montreal_East_QB \ TLA_480\10762C\... \PLANT\Projects\CAN138-Varennes_QB\300_MTON \10133C\... \PLANT\Projects\USA357-Texas_City_2\T-1800\12711B\...
Below this level is where the Bentley AutoPLANT project file share resides. The folder structure and contents is controlled with Bentley Vision. Unless it is a ProjectWise enabled project, users should only use Bentley Vision to access and modify the project content. The next section will cover project creation using Bentley Project Administrator V8i.
2. Browse to the PLANT_TYPE folder level which is the actual Local Project Root and notice the OK button is now enabled. Click OK to add this project to your local list of AutoPLANT projects.
3. Click the + sign to open the tree structure and see the projects under the Local Projects Root you just added. Highlighting the project will challenge you with the Login to Project dialog.
4. Enter the correct User Name and Password as required for the project roots Access.mdb file. You can check Save Password if you wish.
2. Select Make New Folder and type in a new project root folder. Example: C:\PLANT\Projects\USA926-Bridgeton, NJ\...
3. Click OK.
A new project may now be created under the new Local Project Root folder by using one of the following methods: Select File > New from the menu. Right-click on the root folder in the navigation tree, then select New from the context menu displayed. The New Project - Provider Type dialog will appear. Select Access for Distributed mode or SQL Server for Central mode projects.
6. At the New Project - Base Template and 3D Settings dialog leave the Base Schematic Template as the default Standard Base Project. Select the 3D Modelling Project Settings. For Praxair projects you must use the correct PX_ prefixed configuration. Select PX_WARMEND_MMetric Click Next >.
7. Accept the default New Project - Project Paths. Click Next >.
8. At the New Project - Details dialog the only required field is the Project Name. The rest are informational fields only. For Praxair projects the Project Name is the Project Number
Example:
Fill in the details and click Finish. You will see the Creating Project status bar.
9. When the process is completed you will see Ready in the bottom-left corner. You can also confirm the Mode, Version and Units Type.
Do NOT check the Enforce password policy, Enforce password expiration and User must change password at next login. Default database can be left as Master. Default language can be left as <default> c. Create new project database: i. Database name should be in the format ap_<projectnumber>_<2D>/<3D> e.g. ap_12711B_2D or ap_13593B_3D .
d. Configure the SQL Server Account created in step 1 to have db_owner rights to the project database.
The new project may now be created under the network Local Project Root folder by using one of the following methods: Select File > New from the menu. Right-click on the root folder in the navigation tree, then select New from the context menu displayed. The New Project - Provider Type dialog will appear. 2. Choose SQL Server and click Next>.
DO NOT check Use Multi Project Mode. DO NOT change the Project Schema Location. Leave it as the default Access database.
3. At the New Project - Base Template and 3D Settings dialog leave the Base Schematic Template as the default Standard Base Project. Select the 3D Modelling Project Settings. For Praxair projects you must use the correct PX_ prefixed configuration. Select PX_WARMEND_MMetric BE SURE to check the Use Central Project Mode box. Click Next >.
4. Accept the default New Project - Project Paths. Click Next >.
5. At the New Project - Details dialog the only required field is the Project Name. The rest are informational fields only. For Praxair projects the Project Name is the Project Number
Example:
Fill in the details and click Finish. You will see the Creating Project status bar.
6. You will be shown the Data Link Properties dialog. Enter the correct SQL Server name. Enter the User name: and Password: as provided by the Database Administrator. IMPORTANT: BE SURE to check Allow saving password and BE SURE that you have selected the correct project database.
Click Test Connection. When you see that the Test connection succeeded click OK. Click OK one last time.
7. When the process is completed you will see Ready in the bottom-left corner.
The project is now created. BEFORE allowing users access to the project, please read and implement Chapter 2:
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) Project Administration - Creating Project Specific Bentley Vision V8i STARTUP Icons
Chapter 2
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) Project Administration - Creating Project Specific Bentley Vision V8i STARTUP Icons
Initial Project Creation
The Project Administrator, upon creation of a new AutoPLANT Plant Design V8i (SELECTseries 1) project from Chapter 1, needs to set up the project specific Bentley Vision V8i startup icon for the users.
Getting Started
Each project comes with the following folder: Config\Custom\STARTUP\...
3. Right-mouse click > Edit on the COPY Me to your desktop icon. This will open the Vision.bat file. (For XM Legacy projects edit the COPY Me to your desktop V8i_XM_Legacy icon). Replace the following two lines by pasting the STARTUP folder path into the file as shown below:
Replace: C:\Program Files\Bentley\Plant V8i\Config\PX_COLDBOX_MMetric\Custom\STARTUP With: C:\PLANT\Projects\USA926-Bridgeton, NJ\14646B\Config\Custom\STARTUP 4. Next, replace the PROJECT_ROOT path as follows:
Replace: G:\PLANT\Projects\PROJECT_ROOT With: C:\PLANT\Projects\USA926-Bridgeton, NJ 5. You must also replace the PROJECT_DIR path as follows:
6. Finally, add the PROJECTNAME to the following two lines. Save and close.
Update: C:\Documents and Settings\All Users\Application Data\Bentley\Plant V8i\Config With: C:\Documents and Settings\All Users\Application Data\Bentley\Plant V8i\Config\ 14646B
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) File Naming Convention and Reference Model Hierarchy Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production New Document Creation
Chapter 3
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) File Naming Convention and Reference Model Hierarchy
Due to the introduction of Bentley ProjectWise and the enhanced Bentley Vision feature set, the document management issues of the past pertaining to file share directory structures has been greatly simplified. The Praxair customizations for Bentley AutoPLANT Plant Design V8i (SELECTseries 1) has been stripped down to the following REGAPPS and LOCATION: AutoPLANT Piping = AT_PIPE AutoPLANT Equipment = AT_EQP AutoPLANT Structural = AT_STRUCT AutoPLANT Raceways = AT_ELECT AutoCAD = AT_ACAD > > > > > \documents\ PIPE\... \documents\ EQP\... \documents\ STRUCT\... \documents\ ELECT\... \documents\ ACAD\...
Design packages will be Document Grouped within Visions Display Options. (See the Praxair documentation on Bentley Vision V8i (SELECTseries 1) for instruction on the use of AREA folders in the DOC_REG)
Naming Conventions
To facilitate smoother administration of project documents, it is recommended that all models that get created for each application are clearly and consistently named using an easy to identify description or TAGNUMBER and suffixed with their corresponding REGAPP. Example: AutoPLANT Piping model CB_INT_PIPE.dwg AutoPLANT Equipment model AV-0200_EQP.dwg (vessel models associative primitives and nozzles) AutoPLANT Structural model AV-0200_STRUCT.dwg (vessel models structural components) IMPORTANT NOTE: These are examples of root-level models and when referencing each other, are to use the OVERLAY attachment method only.
CB_INT_PIPE_ASSY.dwg
Drawing Production
When the time comes to generate layout drawings, we launch AutoPLANT Piping and go through the procedures outlined in the Praxair documentation listed below. At this point when we attach the reference models, it is only the overall model that gets attached. The rest of the models will be automatically brought along and attached. If the project utilizes Work Areas, it is as simple as inserting a pre-generated view into the layout and the references will automatically be attached. Example: Layout Drawing B-XXXXXXX.dwg References (Attached) CB_OVERALL_ASSY.dwg
BEFORE allowing users to start creating project documents have them read Chapter 4:
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) - Drawing Production New Document Creation
Chapter 4
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) Drawing Production - New Document Creation
Document Creation Methods
In Chapter 3 - File Naming Convention and Reference Model Hierarchy we covered project structure. Now we are ready to start creating project documents. The following section covers document creation and grouping using two methods: Non-ProjectWise Enabled: Bentley Vision V8i is used as a document interface to access and create documents. ProjectWise Enabled: If the project is ProjectWise enabled proceed to the appropriate section in this chapter.
Getting Started
What Is Bentley Vision V8i
Bentley Vision V8i provides an easy-to-use environment to manage critical plant data and documentation. The tree-like user interface allows you to quickly navigate to a specific component to view operating data and associated documentation. Vision and the P&ID Workgroup share a common relational database model for storage of all plant data including process equipment, lines, valves and instrumentation. Changes made to a P&ID are immediately available through the Vision interface. By sharing a common relational database, errors and data maintenance costs associated with duplicate data are virtually eliminated. Launch Bentley Vision V8i using the STARTUP icon created in Chapter 2. Once in the project you will see the interface below. The current project is identified along the top bar and in the bottom-left corner.
3. Enter a name for the document in the File Name field. Entering a description is optional but recommended (the Name and Location fields auto-populate). Then select the appropriate application from the pick-list and press Record Only. This procedure creates a new document record without actually launching the associated application.
4. Notice the new document record is displayed under an Area Not Defined folder in the navigation tree. This is how Bentley Vision V8i displays a blank Area value within the DOC_REG.DBF table for all newly created entries.
5. To associate the document record with the correct Document Grouping, left-click the Area Property in the Properties tab. For Praxair configurations this pull down [GridLists] menu is pre-populated with Praxair defaults. Make your selection from the pick-list. (NOTE: We will cover how to modify these as needed a little later on.)
6. To update the navigation tree Document Grouping, highlight the application and select Display > Refresh Tree or you can press function key F5.
7. Each of the applications in the navigation tree will function the same way when adding or creating new documents or document records. ISOGEN documents, when generated will also register in the DOC_REG and also show up under an Area Not Defined folder.
3. Like before, enter a name for the document in the File Name field. Then select the appropriate application from the pick-list, but this time press Create. This procedure creates a new document and launches the associated application.
4. After saving and closing AutoCAD notice the new document record is displayed under an Area Not Defined folder in the navigation tree.
5. Like before associate the document record with the correct Document Grouping, by leftclicking the Area Property in the Properties tab. Make your selection then update the navigation tree Document Grouping by highlighting the application and selecting Display > Refresh Tree or by pressing function key F5.
Chapter 5
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) Drawing Production - Work Area Setup
Work Area Creation
The Project Administrator, upon creation of a new AutoPLANT Plant Design V8i (SELECTseries 1) project from Chapter 1, needs to set up the project specific Bentley Vision V8i startup icon for the users.
Getting Started
1. To setup a Work Area in AutoPLANT Plant Design V8i you must have a Piping session open. Using the pull down menu: Piping > Drawing Production > Work Area Setup You will see the Work Area Setup dialog box. Select Open
2. You will then see a list of Praxair pre-populated work areas contained in the current project. Select the one you wish to create and click OK.
3. Next, we want to build a list of Reference Drawings by clicking Add and then OK.
4. At the Project Documents Selection dialog box highlight the location you wish to attach and click the arrow button shown.
6. Verify the Membership Status. Normally, if the current drawing is an assembly model you would set the status to Guest. Select Done and if prompted to save changes select Yes.
Chapter 6
Bentley AutoPLANT Plant Design V8i (SELECTseries 1) Drawing Production - Drawing Flattener
Drawing Flattener
This is a Bentley AutoPLANT V8i utility that generates a flat AutoCAD file from a source files layout view. It must contain at least one MVIEW viewport of the 3D model. Much like how ISOGEN generates an isometric drawing, this output file is an unintelligent snapshot of the source file that shows visible and hidden edges on separate layers.
Getting Started
1. Drawing Flattener V8i is launched from the Start menu. Start > All Programs > Bentley > Plant V8i > Tools > Drawing Flattener Or from: C:\Documents and Settings\All Users\Start Menu\Programs\Bentley\Plant V8i\Tools
2. You will see the Bentley AutoPLANT Drawing Flattener V8i (SELECTseries 1) interface below:
3. You can add files to the list from either the File pull down menu or from the toolbar button menu.
4. Browse to the folder where the layout drawings that you wish to flatten reside. Make your selection and click Open.
5. AutoCAD will open and close a few times to build the selection set. When it is ready you will see an open empty AutoCAD session and your selection in the list. You can start flattening from the pull down menu File > Flatten or from the toolbar button menu. If you have a previously flattened file you will be prompted to overwrite it. Click Yes.
6. Depending on the complexity of the source file, the procedure can take anywhere from as short as 2-3 minutes or as long as 10-15 minutes. It all depends on how many viewports the source file contains and how many references models are being processed. It is recommended you not work on other tasks while the procedure runs. You may inadvertently interrupt the flattening process.
7. When the procedure has successfully completed you will see a green check next to the file. You can
CASING QUADRANT_2
35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82
Orange
0.50 0.50 0.25 0.25 0.25 0.25 0.18 0.70 0.13 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.50 0.50 0.50 0.25 0.25 0.25 0.25 0.25 0.25 0.35 0.18 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.50 0.50 0.50 0.25 0.25 0.25 0.25 0.25 0.25
0.020 0.020 0.010 0.010 0.010 0.010 0.007 0.028 0.005 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.010 0.010 0.014 0.007 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.010 0.010
KETTLE5 KETTLE6
TEXT-THIN FOUNDATION
STEEL_PIPE_SUPPORT STEEL_GRATING
83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130
Cyan
Cyan
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.35 0.50 0.50 0.50 0.50 0.50 0.50 0.25 0.25 0.25 0.25 0.13 0.70 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.18 0.25 0.35 0.25 0.25 0.25 0.25 0.25 0.25 0.25
0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.014 0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.005 0.028 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.007 0.010 0.014 0.010 0.010 0.010 0.010 0.010 0.010 0.010
BLDG REVISION
CASING QUADRANT_4
131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178
0.50 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.35 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.50 0.50 0.50 0.25 0.25 0.25 0.25 0.50 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.13 0.13 0.25 0.25 0.25 0.25 0.25 0.25
0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.010 0.010 0.014 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.005 0.005 0.010 0.010 0.010 0.010 0.010 0.010
179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226
0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.50 0.50 0.50 0.25 0.25 0.25 0.25 0.25 1.00 0.13 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.50 0.50 0.50 0.50
0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.020 0.020 0.020 0.020 0.020 0.010 0.010 0.010 0.010 0.010 0.039 0.005 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.020 0.020 0.020 0.020 0.020
MATCHLINES GRIDLINES
TEXT_HEAVY
227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255
0.25 0.25 0.25 0.25 0.35 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.18 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.50 0.50 0.18 0.25
0.010 0.010 0.010 0.010 0.014 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.007 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.010 0.020 0.020 0.007 0.010
TEXT_BUBBLE
Removing AutoPlant XM
After removing all AutoPlant XM applications (including ProjectWise) it is necessary to remove all the Bentley folders and registry entries from the users machine before installing AutoPlant V8i. Make sure the user has admin privileges on the machine. Also, make sure the user has checked the option Show Hidden Files and Folders in the View tab in Folder Options in Windows Explorer. Note: It is not necessary to remove AutoCAD before installing V8i.