FRAME DETAILS
technical

02

COMMITMENT IS THE DIFFERENCE

FIXING DETAILS
technical

03

The following Fixing Mechanisms can be provided on request

COMMITMENT IS THE DIFFERENCE

CEILING DIFFUSERS
technical types -CD, CAB

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

CEILING DIFFUSERS
Details FIXED BLADE CEILING DIFFUSER - CD
Versatility is the key to why the popular directional or pattern-type diffusers are being used so widely for so many different applications. Recommended for heating, ventilation, and cooling, the directional type diffuser provides directed air diffusion, channelling the designed amount of conditioned air into the areas where it is needed. Available in a wide range of sizes, both square and rectangular. There's the choice of one, two, three, four way patterns segmented in rectangular, corner, "y" or diagonal configurations. This takes care of and permits changes as the use or arrangement of conditioned space is varied. The desired versatility is designed into the diffusers. Offered exclusively in extruded aluminium, the diffuser models provide the best robustness and durability combined with inflamibility in directed air diffusion. The core is easily removable for access to the duct. The frame and core are constructed of 1.25mm thickness extruded aluminium. All models can be supplied with a surface finish off temperature-set white powder coated paint preceded by a seven-stage preparation process of degreasing, acid bathing and passivation. This process ensures proper paint adhesion which provides long lasting aesthetics and durability. To enhance the appearance of the units, the finest available paints are used which can be matched to your colour requirements. Optional aluminium paint is available at no extra charge. There are two frames available depending on the application in use. The flat frame is standard whilst a bevelled frame can be supplied on request.

02

ADJUSTABLE BLADE CEILING DIFFUSER - CAB


Further versatility is added to the diffuser range by way of adjustable blades. A similar range of blow patterns as for fixed ceiling diffusers are available. Adjustable blades allows ultimate control in the direction of flows.

FEATURES
All Aluminium construction offers exceptional quality and performance. Light in weight. yet strong and durable. Wide range of sizes, both square and rectangular, Other finishes available upon request. Complete selection data to ensure quiet, draft less air distribution. Tested and rated in accordance with specifications.

CEILING DIFFUSERS
Details
The performance data which follows permits quick, easy and accurate selection of diffusers. Two groups of data are required for selection. The first group is that established by the structural and room-use considerations. The second group consists of the performance characteristics of the diffusers. Consider first the spaces which are to be conditioned and their effects upon outlet selection.

03

Patterns Requirement
The pattern requirement is determined by the shape of the space to be conditioned, the number of diffusers in it, and the type and location of lighting fixtures or other devices mounted on the ceiling. For example a two-way opposite pattern pattern 2A, 2B or 2C - might be used in a corridor. A larger area can often be divided into squares or rectangles of nearly equal size and, if a diffuser can be located in the center of each of these areas, patterns 4A or 4B could be used for four-way delivery.

AIR FLOW
The performance data which follows permits quick, easy and accurate selection of diffusers. Two groups of data are required for selection. The first group is that established by the structural and room-use considerations. The second group consists of the performance characteristics of the diffusers. Consider first the spaces which are to be conditioned and their effects upon outlet selection.

Throw Requirement
The required throw is determined from the building plan after the diffuser location has been decided. The throw requirement is the distance from the diffuser to the nearest enclosing wall. In some cases the throw requirement will be the distance from the diffuser to the intersection of its air stream with air being delivered from another diffuser. For high ceiling applications, the throw requirement may be measured as the horizontal distance described above plus the vertical distance from the diffuser to occupied zone. This is usually considered to extend to the 1,5m level in the room. Another consideration is diffuser mounting height. As air travels from a diffuser, room air is entrained into the supply air stream and the delivery pattern thickens. If the throw requirement is too great, the lower part of the supply air stream can intrude into the occupied zone of the conditioned space. To avoid this, diffusers should be located so that the throw requirement is no greater than 1.5 times the diffuser mounting height. For example, in a space with a 3.6m ceiling height diffusers should be so located and in such numbers that the required throw of any one diffuser Vi/auld not exceed 5.5m. The final consideration is the pressure loss of the diffuser.

TABLE 1 - Recommended NC Level Design Goals

NC LEVEL
The permissible sound level in each space may be specified by the owner or the architect, or it may be determined as an engineering design goal. Table 1 contains an abbreviated list of design goals for air-conditioning sound control in common occupancies.

CEILING DIFFUSERS
Details TABLE 2 - Recommended Max Throw Requirement

04

The basic selection data in Tables to follow for all directional diffusers. The table list performance data as a function of the air velocity in the neck of the diffuser. It lists several sizes for each core pattern and gives the neck area, expressed in m2, for each diffuser size. Performance factors listed are the air volume delivered through the diffuser, the NC level, the air volume delivered through each side of the diffuser, and two values of throw. The values of throw shown in the Tables are bases upon studies of air motion in the occupied zone under conditions of cooling system operation.

When a diffuser is equipped with an opposed blade damper (OBD), both the total pressure requirement and the NC level increase. The OBD increases the total pressure requirement of a diffuser by 10 percent. The NC addition, when the OBD is wide open, can be determined from Table 4. When the OBD is throttled, the NC factor for the throttled damper can be determined from Figure 17. The opposed blade action of the damper permits equal distribution of air over the entire face of the diffuser. The operating mechanism provides for positive damper setting in a position from fully open to fully closed. See holes on OBD for additional information.

ADDITION TO OPEN DAMPER NC

TABLE 3 - Velocity Pressure

The allowance in the design of the system for outlet pressure loss should not be exceeded by the diffuser pressure loss. The room velocity, YR, should not exceed O.6m!s when the diffuser selection is based upon minimal throw. When diffuser selection is based upon maximum throw, the room velocity, YR, should not exceed O.4m!s. The tabulated values of throw apply for diffusers mounted in a ceiling. Selection data are given for neck velocities ranging from 1.5 to 3.5m!s Also listed are values of total pressure drop through the diffuser at each of these neck velocities. The total pressure requirement is the sum of the static pressure drop of the air as it passes through the diffuser and the velocity pressure of their air at the neck of the diffuser. If the static pressure is required, it can be determined by subtracting the velocity pressure from the total pressure.

TABLE 4 - NC ADDITION FOR DIRECTIONAL DIFFUSER WITH OBD.

CEILING DIFFUSERS
Type - CD

05

Dimensions: "D" Celing Opening Over Flange

= Outside Neck = "D" + lOmm = "D" + 120mm

Dimensions: "D" Celing Opening Over Flange

= Outside Neck = "D" + 75mm = "D" + 130mm

TYPE CD: Ceiling Diffusers manufactured from Anodised Aluminium with Removeable Cores Accessories OBD = Note Opposed Blade Damper remains in position when core is removed Plenum Box with spigot Ceiling Plate Standard Flat SB 1. 2. 3. PB Fits over neck of CD +/-2mm clearance all round CP Fixed to neck of CD on request only Refer selection data for standard size (increments 76mm) Standard Bevel on request only

PB CP Frame Options Finish Options Blade Spacing: SF

= = =

NA = Natural Anodised EPC = Epoxy Powder Coating 38mm Standard

Type CD:

Ceiling Diffuser available in a choice of air distribution patterns.

Note:

T1 is always longer than T2 except in 3A where T1 = T2 All flow patterns are given looking at Diffuser face

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are Outside Neck Size - "D" Type CD Core 3A indicates Ceiling Diffuser with 3 way blow core

CEILING DIFFUSERS
Type - CD

06

Dimensions: "D" Celing Opening Over Flange

= Outside Neck = "D" + lOmm = "D" + 120mm

Dimensions: "D" Celing Opening Over Flange

= Outside Neck = "D" + 75mm = "D" + 130mm

TYPE CD: Ceiling Diffusers manufactured from Anodised Aluminium with Removeable Cores Accessories OBD = Note Opposed Blade Damper remains in position when core is removed Plenum Box with spigot Ceiling Plate Standard Flat SB 1. 2. 3. PB Fits over neck of CD +/-2mm clearance all round CP Fixed to neck of CD on request only Refer selection data for standard size (increments 76mm) Standard Bevel on request only

PB CP Frame Options Finish Options Blade Spacing: SF

= = =

NA = Natural Anodised EPC = Epoxy Powder Coating 38mm Standard

Type CD:

Ceiling Diffuser available in a choice of air distribution patterns.

Note:

T1 is always longer than T2 except in 3A where T1 = T2 All flow patterns are given looking at Diffuser face

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are Outside Neck Size - "D" Type CD Core 3A indicates Ceiling Diffuser with 3 way blow core

CEILING DIFFUSERS
Type - CD
General Notes On Selection

07

(i) "TOTAL VOLUME" means Total Volume per outlet. (ii) "THROW MIN-MAX" is to a terminal velocity of 0.75 m/s at Minimum throw and 0, 25rn1s at maximum throw. (iii) "VOLUME T1/T2" means volume per side i.e. T1/T2 = 0,092/0,040 means Volume on T1 = 0,092 and Volume on T2 = 0, 040 (iv) "T1 is always longer than "T2" except on type 3A where T1 = T2. (v) Noise Levels: "A" = Up to 30 dbA "B" = 31 to 40 dbA "C" = 41 to 50 dbA (vi) Ordering: When ordering T1 (longest side) is always given first (vii) Sizes shown refer to over outside neck. (viii) For sizes not shown please contact nearest sales office. (ix) Selection Example: Problem: Select a 4 way blow diffuser to delivery 0,25 m3/s with a throw of 3,5m in all directions. Solution: Use Size 381 x 381 Core 4A, Pressure drop = 15 N/m2. Noise level = A.

Performace Data

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

08

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

09

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

10

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

11

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

12

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

13

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

14

CEILING DIFFUSERS
Type - CD
Performace Data (Continued)

15

CEILING DIFFUSERS
Ceiling Plate - CP

16

Type CP: Ceiling Plate manufactured of electro galvanized flat sheet for installation in lay-in "T" Bar suspended ceiling system. It is easily relocated to meet changing space requirements. It also fits all common suspended grid ceilings, and are available with epoxy powder coating finish to your colour requirements.

Ordering Procedure - Example

CEILING DIFFUSERS
Type - CAB

17

TYPE CAB:

Curved Adjustable Blades - Ceiling Diffuser Manufactured of extruded type 50S Anodising Grade Aluminium with individually adjustable blade. The blades are held in place by plastic friction grommets or wire. PCS OBD PB CP = = = = Punched Counter Sunk Holes Opposed Blade Damper Plenum Box with spigot Ceiling Plate ON OS OP = = = Over Neck Over Flange Opening or Normal Duct Size

Accessories

Frame Options

30mm Standard 20mm 50mm WS NA = =

Finish Options

Wet Spray Colour Natuaral Anodised Aluminium

Blade Spacing:

19mm Standard

Type CAB - Ceiling Diffuser available in a choice of Air Distribution Patterns Note: H1 is always longer than H2 All Flow Patterns are given looking at difuuser face

Ordering Procedure - Example

Note: (1) (2)

Dimensions given are for over Flange size Type CAB Core 2A indicates CAB with two way blow

CEILING DIFFUSERS
Type - CAB

18

GENERAL NOTES ON SELECTIONS A) TOTAL VOLUME MEANS TOTAL VOLUME PER OUTLET - m3/sec. B) THROW MIN-MAX IS TO A TERMINAL VELOCITY OF 0.64 MIS MINIMUM THROW AND 0.031 MIS AT MAXIMUM THROW. C) VOLUME HI + H2 MEANS VOLUME PER RESPECTIVE SIDE. D) HI IS ALWAYS LARGER THAN H2 , EXCEPT ON TYPE 3A WHERE Hl=H2. E) NOISE (NC) LEVEL A = 0-30 B = 31-35 C = 36-40 D = 41-45 SELECTION OF CURVED ADJUSTABLE BLADE GRILLE IS BASED UPON THROW AND M3/S REQUIREMENTS. THE THROW, M3/S AND PRESSURE DROP APPLY WHEN THE INDIVIDUAL BLADES ARE ADJUSTED IN THE MANNER ILLUSTRATED BELOW. OTHER BLADE SETTINGS WILL PROVIDE SIGNIFICANTLY DIFFERENT THROWS AND AIR DELIVERIES. THE M3/S TABULATED IS THE VOLUME DELIVERED BY THE GRILLE. BALANCING OF CURVED BLADE IS ACCOMPLISHED BY MEASURING FACE VELOCITY. THE MEASURED VELOCITY CAN BE CORRELATED TO TABULATED FACE VELOCITY AND M3/S WHEN THE BLADES ADJUSTMENT IS THAT AS ILLUSTRATED. THE PERFORMANCE OF RECTANGULAR GRILLES WITH AREAS EQUAL TO SQUARE GRILLES, WILL BE THE SAME.

CEILING DIFFUSERS
Type - CAB

19

SELECTION DATA

CORE PATTERN

CEILING DIFFUSERS
Type - CAB

20

SELECTION DATA

CORE PATTERN

CEILING DIFFUSERS
Type - CAB

21

SELECTION DATA

CORE PATTERN

CEILING DIFFUSERS
Type - CAB

22

SELECTION DATA

CORE PATTERN

COMMITMENT IS THE DIFFERENCE

SUPPLY AIR GRILLES


technical types -DD, SD

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

SUPPLY AIR GRILLS


Details SELECTION OF SUPPLY GRILLES AND REGISTERS
The performance data which follows permits quick, easy, and accurate selection of supply grilles and registers. Two groups of data are required for selection. Inherently required by the structural and room use considerations. The required performance characteristics of the supply outlets. Consider first the spaces which are to b conditioned and their effects upon outlet selections. 1. m3/s The air volume to be delivered to each space is determined by overall system design, and the m3/s per outlet is determined by the number of outlets which supply each space. 2. NC Level The permissible sound level in each space may be specified by the owner or the architect, or it may be determined as an engineering design goal. Figure 1 contains an abbreviated list of design goals for air conditioning sound control in common occupancies. 3. Throw Requirement The required throw is determined from the building plan. Often the throw requirement will be the distance from the outlet to the opposite wall. Sometimes it will be the distance from the outlet to the intersection of its air system with air being delivered from another supply outlet. Other items to be considered are the spread requirement, permissible drop, and acceptable pressure drop. The air stream should spread sufficiently so that the wall or space at the end of the throw is blanketed.

02

The drop of the air stream should not be so great that it is within 1.5m of the floor at the end of the throw. Finally, the allowance in the design of the system for outlet pressure loss should not be exceeded. After the design requirements - air flow, NC level, throw spread, and drop requirements - are known, the outlet can be selected

Selection of Grilles and Registers 19mm Louvers


The basic selection data are given in the Tables to follow for grilles and registers having louvers on a 19mm spacing. For each listed air volume, the static pressure drop and two values of throw are given for each grille area factor. The minimum throw is the distance the air will travel to a terminal velocity of 0.64m1s; the maximum throw is the distance of air travel to a terminal velocity of 0.41m1s. For each m3/s and the grille size, selection data are given at three spread angles -0, 22 and 45. NC level is coded in 5 db increments for each m3/s, spread angle, and area factor in the table.

SUPPLY AIR GRILLS


Details TABLE 5 RECOMMENDED NC LEVEL DESIGN GOALS

03

To obtain the static pressure loss of the register, multiply the grille static pressure by the "Ps multiplier" of the damper. Note these two factors vary with grille width.

Drop
The drop of a cooled air stream is shown in Table 7. This is the vertical distance which the air will have dropped as it travels across the room and slows to a velocity of 0.6mJs. Note that, at a constant air flow, the drop increases as the grille area factor increases. This occurs because the air velocity at the grille face decreases as the grille area increases. On the other hand, it must be realized that the further the air travels - that is: the longer the throw - the greater the drop becomes. For this reason, drop increases as air flow is increased if the grille size and spread angle are kept constant. The spread angle setting affects all of th performance characteristics of a grille. The following general rules can be used to estimate the spread: 1. For 0 spread angle, the total spread of the air stream is one-third of the throw. 2. For 22 spread angle, the total spread of the air stream is about 45 percent of the throw. 3. For 45 spread angle, the total spread of the air stream is 1.5 times the throw. These values are the total spread of the air stream, but they do not consider grille width which should be added to the spread estimated above.

The area factor shown at the top of each column is the key to actual grille-size selection. The Grille Sizes shown are not the only grilles which could be selected. Complete size selection is given, in Tables 6, 7 & 8 to follow, which relates grille height and grille width to the area factor. Selecting a register requires that the effects of dampers on grille performace be considered. Throw, spread, and drop are not affected by the dampers of a register - if the damper is wide open - but the pressure requirement and the sound level generated by a register are different from those of a grille only. The effects of the damper on these performance characteristics are shown in Table 6 to follow. To obtain the NC level of a register add the "NC addition" factor to the NC level of the grille as determined from Tables 6 & 9 to follow.

SUPPLY AIR GRILLS


Details

04

If three grilles serve the space, determine the difference between the combined NY level for the fIrst two grilles and the NC level of the third grille. Determine the NC addition as above, and add this to the combined NC level of the first two units.If the difference between NC levels of two grilles is 10 db or more, the sound generated by the quieter grille will not affect the space NC.

TABLE 6 - NC AND STATIC PRESSURE FACTORS FOR REGISTERS (OPEN DAMPER)

NOTES: (1) NC Addition plus grille NC equals register NC level. (2) Ps Multiplier times grille static pressure equals register static pressure.

TABLE 7 - DROP OF COOLED SUPPLY AIR

For larger spaces and specific room absorption conditions, a calculation using sound power level data is required. Closing the damper of a register results in: The restriction of the air flow, thereby increasing the pressure drop and decreasing the air flow. The damper generating sound - increases the NC level. For example a damper closed sufficiently to double the pressure loss of a register (pressure ratio of 2) causes and NC increase of about 7 db. (As a rule of thumb - and for general reference only - it can be assumed that closing an opposed blade damper to an effective opening ratio of 70 percent doubles the pressure loss of the damper outlet combination. Closing the damper to an effective opening ratio of fifty percent increases the pressure loss to 4-times the grille-open damper loss.)

SUPPLY AIR GRILLS


Details

05

Combining Sound Sources


The NC data for registers and grilles, given in tables to follow, contain an allowance for the sound adsorbing properties of the average room and its contents. This absorption is assumed to be 8 db. For relatively small spaces - about 73.5 sq m. or less of floor area and ceiling height of 3.0m or less - the following simplified method for estimating NC level produced by combinations of supply and return registers and grilles can be used: 1. Determine the difference in NC level between the grilles or registers having the highest NC and the second highest NC level. 2. From table 9 to follow determine the number of decibels to be added to the NC level of the grille having highest NC level. This sum is the combined NC level generated by the two grilles or registers.

TABLE 8 AREA FACTORS, FOR SELECTION OF SUPPLY GRILLES - 19mm, SD AND DD

SUPPLY AIR GRILLS


Details

06

TABLE 9 - NC ADDITION FOR COMBINING EFFECTS OF SOUND SOURCES

Selection of Grilles and Registers - 19mm Blade Spacing


Grilles and registers having louvers (blades) on 19mm spacing are selected in a similar manner. The structural and room-use factors, the air volume, and the throw, spread drop and NC requirements must be considered in the same way as with other grilles and registers. For each listed air volume, the static pressure and two values of throw are given. The minimum throw is the distance the air will travel to a terminal velocity of 0.64m/2; the maximum throw is the distance of air travel to a terminal velocity of 0.41m/s. Selection data are given at each of three spread angles - 0, 22, and 45 - and for NC level in 5 db increments. The area factor shown at the top of each column permits flexibility in grille-size selection.

SUPPLY AIR GRILLS


Type - DD

07

TYPE DD:

Double deflection supply air grilles manufactured of extruded type 50S anodising grade aluminium with individually adjustable front vertical and rear horizontal louvres held in place by starlock washers and spring wire. OBD PC CF 30mm 20mm 50mm NA EPC WS = Opposed Blade Damper = Punched counter sunk holes = Concealed Fixing Standard

Optional Accessories

Frame Options

Finish Options

= = =

Natural Anodised Epoxy Powder Coating Wet Spray Colour

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for opening size into which grille will fit (i.e Normal Duct Size) If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange.

SUPPLY AIR GRILLS


Performance Data - DD - SD

08

SUPPLY AIR GRILLS


Performance Data - DD - SD

09

SUPPLY AIR GRILLS SUPPLY AIR GRILLS


Details Type - DD

10

TABLE 5 - RECOMMENDED NC LEVEL DESIGN GOALSindividually adjustable louvres - vertical and horizontal - with or without a damper attached, The two sets of
allow these grilles to provide maximum flexibility of adjustments for spread and throw requirements. The multi directional flexibility allows for multi-directional air supply. They are recommended for high sidewall, bulkhead or duct mounting and can be used for heating, cooling, or ventilating applications

GENERAL SPECIFICATIONS
All models feature two sets of individually adjustable blades - vertical and horizontal - spaced at 19mm apart, and fitted into a 20, 30 or 50mm frame. The optional opposed blade damper is constructed using extruded aluminium blades and frame. The individual blades are secured by corrosion resistant star lock washers with added adjusting tension supplied by corrosion resistant spring wire. All models can be furnished with powder coated white finish preceded by five stage preparation process of cleaning, phosphatizing and drying. Grilles can be supplied in natural anodised and white powder coated finishes. Other colours are available on request.

SUPPLY AIR GRILLS


Type - SD

11

These models have one set of individually adjustable blades on a horizontal plane to provide maximum throw requirements or on a vertical plane (on special request) to provide maximum spread adjustment. They are recommended for heating, cooling, and ventilating applications, generally mounted in a high sidewall, bulkhead or duct when either spread or throw only is important. The grilles are provided with or without an opposed blade damper. The adjustable blades are spaced at 19mm, but fixed blades with 13,21 and 26mm spacing can be offered at special request.

GENERAL SPECIFICATIONS
All models feature one set of individually adjustable blades of extruded aluminium set in a 20, 30 or 50mm extruded aluminium frame. An optional extra opposed blade damper is constructed of extruded aluminium blades can be supplied on request. All models can have a powder coated white surface finish preceded by five stage preparation process of cleaning, phosphatizing and drying. Other colours are available on request. Grilles can also be supplied in natural anodised finish.

SUPPLY AIR GRILLS


Details

12

TYPE SD:

Single Deflection Supply Air Grille manufactured of extruded type 50S anodising grade aluminium with individually adjustable horizontal louvers held in place by starlock washers and wire

Optional Accessories

Frame Options

OBD PC CF 30mm 20mm 50mm NA EPC

= Opposed Blade Damper = Punched counter sunk holes = Concealed Fixing Standard

Finish Options

= =

Natural Anodised Epoxy Powder Coating

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for opening size into which grille will fit (i.e Normal Duct Size) If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange.

COMMITMENT IS THE DIFFERENCE

RETURN AIR GRILLES


technical types -RA, RARB, RAFF, TG, EC

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

RETURN AIR GRILLS


Type - RA

02

These grilles feature light weight extruded aluminium with or without damper attached. The standard grilles are available with fixed horizontal blades spaced at 21mm apart.

GENERAL SPECIFICATIONS
Different spacing can be offered as a special request. The frame is constructed of 1.3mm thickness extruded aluminium with curved fins of extruded aluminium of 1.2 to 1.6mm thickness. The damper is constructed from extruded aluminium blades and frame. Grille can be furnished with powder coated white finish preceded by a five stage preparation process of cleaning, phosphatising and drying. Other colours are available on request. Grilles can also be supplied as natural anodised. For outside weatherproof applications the Return Air Ribbed Blade (RARB) can be offered. This type is particularly suited to grilles for console air conditioners.

RETURN AIR GRILLS


Details

03

TYPE RA

(45deg. Deflection): Return Air Grille manufactured of extruded type anodising grade aluminium with fixed curved blade profile giving low see through characteristics.

This grille may be mounted vertically or horizontally. Optional Accessories

OBD PC CF FS

= = = =

Opposed Blade Damper Punched counter sunk holes Concealed Fixing Rear Fixing Straps

Frame Options

30mm Standard 20mm 50mm NA EPC WS 13mm 19mm 21mm 26mm = = = Natural Anodised Epoxy Powder Coating Wet Spray Colour

Finish Options

Blade Spacings

Standard

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for over flange size If 13mm, 19mm, 26mm Blade Spacing required, enter under SPECIAL INSTRUCTIONS

RETURN AIR GRILLS


TYPE - RA

04

SELECTION DATA
100 A

2.0 1.8 1.6 1.4 1.2 1.0 .9 .8 .7 .6 .5 15 10 8 6 5 4 .3 3 2 1.5 .2 1.0 0.75 .15 0.50 0.1 0.25 Velocity m/s .10 .09 .08 .07 .06 Air Flow m3 / s 0.05 Grillle 150 100 80 60 40 20 15 10 8 6 4 2 1 0.8 0.6 0.4 0.2 225 150 120 90 60 30 15 12 9 6 3 1.5 1.2 0.9 0.6 0.3 0.15 0.075 Grillle + OBD 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 WIDTH mm 350 400 450 500 550 600 HEIGHT mm 300 250 250 150 200 150 100

310 200 350

.4

Pressure N/m2

RETURN AIR GRILLS


TYPE - RARB

05

TYPE RA/RB

Return Air or Discharge Grille with ribbed or un-ribbed blades manufactured of extruded type 50S anodising grade aluminium with fixed horizontal blades.

TYPE RARB Grille can be used internally or externally and is particularly well suited for console air conditioning units. Optional Accessories

OBD WM CF FS D

= = = = =

Opposed Blade Damper Wire Mesh Concealed Fixing Rear Fixing Straps Over Neck Size

Dimensions

Frame Options

30mm Standard 20mm 50mm NA EPC WS = = = Natural Anodised Epoxy Powder Coating Wet Spray Colour

Finish Options

Blade Spacings

25mm Standard 19mm 13mm

Ordering Procedure: Example

Note: (1) (2) (3)

Dimensions given are for over neck size If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange If 13mm, 19mm Blade Spacing required, enter under SPECIAL INSTRUCTIONS

RETURN AIR GRILLS RETURN AIR GRILLS


TYPE -Details RARB FIXED BLADE CEILING DIFFUSER - CD

06

2.0 1.8 1.6 1.4 1.2 1.0 .9 .8 .7 .6 .5 15 10 8 6 5 4 .3 3 2 1.5 .2 1.0 0.75 .15 0.50 0.1 0.25 Velocity m/s .10 .09 .08 .07 .06 Air Flow m3 / s 0.05 Grillle 150 100 80 60 40 20 15 10 8 6 4 2 1 0.8 0.6 0.4 0.2 225 150 120 90 60 30 15 12 9 6 3 1.5 1.2 0.9 0.6 0.3 0.15 0.075 Grillle + OBD 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 WIDTH mm 350 400 450 500 550 600 HEIGHT mm 300 250 250 150 200 150 100

310 200 350

.4

Pressure N/m2

SELECTION DATA

100

RETURN AIR GRILLS RETURN AIR GRILLS


Details FIXED BLADE CEILING DIFFUSER - CD

07 06

RETURN AIR FILTER FRAME RAFF


This model is constructed from extruded aluminium. Core is hinged for easy installation and replacement of ftlters. Core can be of fixed blade type (RA, RARBISB, DD, SD, EC or WL) All models can be furnished with powder coated white fInish preceded by fIve stage preparation process of cleaning, phosphatizing and drying. Other colours are available on request. Can also be supplied in natural anodize.

RETURN AIR GRILLS


TYPE - RAFF

08

TYPE RAFF Return Air Filter Frame Grille manufactured of extruded type 50S Anodising grade aluminium. This Grille consists of a fixed outer frame and hinged inner frame with grille core. The filter media is positioned inside the outer frame behind the hinged grille section. The Grille section is held closed by hidden clips. A handle is provided for opening the grille section. The grille can be utilised without the rear mounted filter section to provide access to Air-conditioning plant mounted above ceilings. Optional Accessories OBD = Opposed Blade Damper PB = Plenum Box with spigots PC = Punched counter sunk holes Dimensions D = Normal Duct Size Frame Options 30mm Standard 20mm 50mm Core SD = Standard
Any of our Standard Blades can be used viz., DD, RA, EC, WL, SGS, SGT, or Perforated Plate. etc.

Blade Spacings Finish Options

Filter Options

Varies per type of blade NA = Natural Anodised EPC = Epoxy Powder Coating WS = Wet Spray Colour 6mm Washable Synthetic Media - Standard Flat Panel Filter as alternative.

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are over flange size First dimensions given is for side on which handle is fitted.

RETURN AIR GRILLS RETURN AIR GRILLS


TYPE Details - RAFF FIXED BLADE CEILING DIFFUSER - CD SELECTION DATA

09 06

100

2.0 1.8 1.6 1.4 1.2 1.0 .9 .8 .7 .6 .5 15 10 8 6 5 4 .3 3 2 1.5 .2 1.0 0.75 .15 0.50 0.1 0.25 Velocity m/s .10 .09 .08 .07 .06 Air Flow m3 / s 0.05 Grillle 150 100 80 60 40 20 15 10 8 6 4 2 1 0.8 0.6 0.4 0.2 225 150 120 90 60 30 15 12 9 6 3 1.5 1.2 0.9 0.6 0.3 0.15 0.075 Grillle + OBD 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 WIDTH mm 350 400 450 500 550 600 HEIGHT mm 300 250 250 150 200 150 100

310 200 350

.4

Pressure N/m2

TRANSFERRETURN AIR GRILLS RETURN AIR GRILLS


Details FIXED BLADE CEILING DIFFUSER - CD

10 06

1) TYPE TG-RA

Transfer Return Air Grilles manufactured of extrudedtype anodising grade aluminium with fixed curved blade profile giving low see through characteristics. They are recommended for walls or partitions where a sight proof transfer grille is requested. It consists of two return air grilles mounted back-to-back.

1) TYPE TG-RA/WL

TTransfer Return AirlWeather Louvres Grilles manufactured of extruded type anodising grade aluminium with fIXed blade profile. They are recommended for interior/exterior wall where a transfer grille is requested.

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for over neck size Partition thickness is entered under special instructions. Neck sizes (depth) may be trimmed, to suit your partition thickness, on request.

COMMITMENT IS THE DIFFERENCE

STRIP GRILLES
technical types -SGT, SGS, FLG

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

STRIP GRILLS
Type - SGT

02

TYPE SGT (0 DEGREE DEFLECTION: Strip Grilles manufactured of extruded Type 50S anodising grade aluminium with ftxed blades. These grilles can be used either vertically or horizontally. They can be used as supply or return Air Grilles and also for fancoil and induction units, and can incorporate access flaps. Optional Accessories

OBD PC CF

= = =

Opposed Blade Damper Punched counter sunk holes Concealed Fixing

SGT13 SGT19 Frame Options

13mm Blade Spacing 19mm Blade Spacing 30mm Standard 20mm 50mm NA EPC WS = = = Natural Anodised Epoxy Powder Coating Wet Spray

Finish Options

Blade Spacings

13mm Standard 19mm 21mm 26mm

Ordering Procedure: Example

Note: (1) (2) (3)

Dimensions given are for over neck size If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange. If 19, 21 or 26mm Blade Spacing required, enter under SPECIAL INSTRUCTIONS.

STRIP GRILLS
Type - SGT

03

SELECTION DATA

NOTE
1) For dimensional data refer to sheet SGT. 2) Selection data is for 13mm blade spacing. 3) Selection data is based on m3/s/metre width. 4) Jet velocity is actual velocity between blades. Average face velocity (25mm from grille) - 65% of jet velocity. 5) Type SGT usually only used for extract.

EXAMPLE (Selection based on 1 metre lenghts of grille) TypeSGT For 0,278 m3/s/metre and 6 metre throw use 137,5mm wide grille (duct width) Jet velocity Pressure drop 4,6m/s 9N/m2 (Extract) or 12N/M2 (Supply)

CONVERSION FACTORS CFM FPM inches WG INCHES X X X X 0,000472 0,005 250 25.4 = = = = m3/s m/s N/m2 mm

STRIP GRILLS
Type - SGT

04

SELECTION DATA

37.5 1.5

1.0 0.9 0.8 0.7 0.6 20 0.5 0.4 10 0.3 0.25 5 0.2 5 4 5 3 0.15 2 4 3 2 1 0.1 0.09 0.08 0.07 0.06 0.05 1 Throe in metres to a Terminal velocity of 0,25m/s 0.5 0.4 0.3 Jet Velocity m/s 1 0.8 0.2 0.2 Extract Grille OBD - ADD 50% Supply Grille OBD - ADD 50% 2 0.5 0.5 1 162.5 175 187.5 200 212.5 225 237.5 250 262.5 275 287.5 300 312.5 325 Opening width mm 10 8 20 20 10 10 112.5 5 3 2 137.5 150 125 100 300 200 100 100 50 50 87.5 75 300 200 62.5 30 50

0.04

0.03 Air Flow m3 / s / metre lenght

Pressure N/m2

NOTE: FOR SELECTION PROCEDURE AND GENERAL NOTES SEE PREVIOUS PAGE

STRIP GRILLS
Type - SGS

05

TYPE SGS (18 DEGREE DEFLECTION): Strip Grille manufactured of extruded Type 50S anodising grade aluminium with fixed blades. These grilles can be used either vertically or horizontally. They can be used as Supply or Return Air Grilles and also for fancoil and induction units, and can incorporate access flaps. Accessories OBD PC CF = = = Opposed Blade Damper Punched counter sunk holes Concealed Fixing

TYPE SGS Frame Options

13mm 30mm Standard 20mm 50mm NA BEW EPC = = = Natural Anodised Baked Enamal White Epoxy Powder Coating

Finish Options

Blade Spacings

13mm Standard 19mm 21mm 26mm

Ordering Procedure: Example

Note: (1) (2) (3)

Dimensions given are for opening size into which grille will fit (i.e Normal Duct Size) If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange. If 19, 21, 26mm Blade Spacing required, enter under SPECIAL INSTRUCTIONS.

STRIP GRILLS
Type - SGS

06

SELECTION DATA

NOTE
1) Selection data is for 13mm blade spacing. 2) Selection data is based on m3/s/metre width. 3) Jet velocity is actual velocity between blades. Average face velocity (25mm from grille) - 65% of jet velocity. 4) Type SGS usually only used for extract.

EXAMPLE (Selection based on 1 metre lenghts of grille) For 0,3 m3/s/metre and 6 metre throw use 150mm wide grille (duct width) Jet velocity Pressure drop 3m/s 6N/m2 (Extract) or 8N/M2 (Supply)

CONVERSION FACTORS CFM FPM inches WG INCHES X X X X 0,000472 0,005 250 25.4 = = = = m3/s m/s N/m2 mm

STRIP GRILLS
Details

07

1.5 37.5

1.0 0.9 0.8 0.7 0.6 20 0.5 0.4 10 0.3 0.25 5 4 0.2 5 3 5 0.15 2 4 3 2 1 0.1 0.09 0.08 0.07 0.06 0.05 1 Throe in metres to a Terminal velocity of 0,25m/s 0.5 0.4 0.3 2 1 0.8 0.5 0.5 162.5 0.2 0.2 Extract Grille OBD - ADD 50% Supply Grille OBD - ADD 50% 175 187.5 200 212.5 225 237.5 250 262.5 275 287.5 300 312.5 325 Opening width mm 1 137.5 150 20 20 10 10 100 5 3 2 112.5 125 87.5 300 200 100 100 50 50 75 300 200 62.5 10 8 30 50

0.04

0.03 Air Flow m3 / s / metre lenght

Jet Velocity m/s

Pressure N/m2

NOTE: FOR SELECTION PROCEDURE AND GENERAL NOTES SEE PREVIOUS PAGE

COMMITMENT IS THE DIFFERENCE

EGG CRATE GRILLES


technical types -EC, ECA

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

EGG CRATE GRILLS


Tupe - ECP

02

TYPE EC Egg Crate Grille manufactured with frame of extruded Type 50S anodising grade aluminium and high density styrene core. Accessories OBD PC CF Dimensions D = = = = Opposed Blade Damper Punched counter sunk holes Concealed Fixing ON / Normal Duct Size ON - Over Neck Size OS - Over Flange

Frame Options Finish Options

30mm Standard A) FRAME NA = Natural Anodised Aliminium BEW = Baked Enamel White B) CORE = High Density Polystyrene = Aliminium

Ordering Procedure: Example

Note: (1)

Dimensions given are for 'OS' = Over Flange

EGG CRATE GRILLS


Tupe - ECA

03

TYPE ECA Egg Crate Grille manufactured with frame of extruded Type 50S anodising grade aluminium and the grid manufactured from 0,5mm aluminium sheet. Accessories OBD PC CF Dimensions D = = = = Opposed Blade Damper Punched counter sunk holes Concealed Fixing ON / Normal Duct Size ON - Over Neck Size OS - Over Flange

Frame Options Finish Options

30mm Standard NA BEW EPC = = = Natural Anodised Aliminium Baked Enamel White Epoxy Powder Coating

Ordering Procedure: Example

Note: (1)

Dimensions given are for 'OS' = Over Flange

EGG CRATE GRILLS


CORES

04

SPECIAL APPLICATIONS
EC & ECA CORES EC & ECA Cores are available with a 10mm channel frame for "Drop In" Ceilings. The channel frame fabricated of electrogalvanised metal and painted. Mitre cuts are not accurate as it is intended for channel to be hidden by ceiling "T". Other Cores are also available on request - Honeycomb - 45 Angled Louvres - Chrome Finish - both Matt or Gloss

EGG CRATE GRILLS


Details

05

SELECTION DATA
100 A

2.0 1.8 1.6 1.4 1.2 1.0 .9 .8 .7 .6 .5 15 10 8 6 5 4 .3 3 2 1.5 .2 1.0 0.75 .15 0.50 0.1 0.25 Velocity m/s .10 .09 .08 .07 .06 Air Flow m3 / s 0.05 Grillle 150 100 80 60 40 20 15 10 8 6 4 2 1 0.8 0.6 0.4 0.2 225 150 120 90 60 30 15 12 9 6 3 1.5 1.2 0.9 0.6 0.3 0.15 0.075 Grillle + OBD 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 WIDTH mm 350 400 450 500 550 600 HEIGHT mm 300 250 250 150 200 150 100

310 200 350

.4

Pressure N/m2

COMMITMENT IS THE DIFFERENCE

DOOR GRILLES
technical types -DG, DG-DR

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

DOOR GRILLS
Type - DG

02

TYPE DG

Door Grille complete with telescopic back frame manufactured of extruded Type 50S anodising grade aluminium. These grilles have ftxed horizontal Chevron Louvres. W UD PC CF = = = = Door Thickness Undrilled Standard Punched counter sunk holes Spring Clip can be supplied if door thickness W is ACCURATELY provided (Door thicknesses vary considerably

Dimensions Fixing Options

Note

Also available without frames

TYPE DG DOOR GRILLE Frame Options Standard Frame = Telescopic Back Frame = NA BEW EPC = = = 20mm 22mm

Finish Options

Natural Anodised Baked Enamal White Epoxy Powder Coating

Blade Spacings

13mm Standard 19mm 21mm 26mm

Ordering Procedure: Example

Note: (1) (2) (3)

Dimensions given are for opening size into which grille will fit (i.e Normal Duct Size) If code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange. If 19, 21, 26mm Blade Spacing required, enter under SPECIAL INSTRUCTIONS.

DOOR GRILLS
Type - DG

03

SELECTION DATA

0.6 100 0.5 A

0.4

100 150

0.3

0.25 150 0.2 200

0.15

5 4 3 2

120 100 50 40 30 20 10

250

200

310 350

250

0.10 0.09 0.08 0.07 0.06 0.05 0.04 1 0.75

300 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 WIDTH mm A 350 400 450 500 550 600 HEIGHT mm

5 2 Face Velocity m/s Pressure Drop N/m2

0.03 Air Flow m3 / s

DOOR GRILLS DOOR GRILLS


Type - DG-DR Details FIXED BLADE CEILING DIFFUSER - CD

04

TYPE DG

Door Grille without telescopic back frame manufactured of anodising grade aluminium. These grilles have fIxed horizontal Chevron Louvres. For dark rooms and other areas where light sensitivity is critical, Type DG-DR is recommended. PC = Punched Counter Sunk Holes

Fixing Methods

TYPE DG-DR DOOR GRILLE Frame Options Finish Options NA BEB EPC = = = = 22mm Standard Natural Anodised Baked Enamal Matt White Epoxy Powder Coating Matt Black

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for opening size into which grille will fIt Horizontal dimension is given fIrst.

COMMITMENT IS THE DIFFERENCE

WEATHER LOUVRES
technical

type - WL

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

WEATHER LOUVRES
Type - WPL

02

TYPE WLP

Weather Louvre manufactured of extruded Type 50S anodising grade aluminium. The fIxed horizontal blades are held in place by screws. Blades are spaced 35mm apart. Standard Spacing = Top Blade fIts flush with frame. Lip of Bottom Blade overlap frame. Accessories WM = Wire Mesh OBD = Opposed Blade Damper NOTE: Adjustment from face of
Louvre is not advisable.

PC FS Dimensions Notes

= =

Punched Counter Sunk Holes Rear Fixing Straps

ON = Normal Duct Size 1) Alternative Meshes available on request. 2) For Weather Louvres smaller than 450 x 300 we recommend the use of Type RA with RARB Blade with19mm spacing.

TYPE WLP: WEATHER LOUVRE Vermin Protection: - Plastic Bird mesh - Standard - Galvanised wire mesh Frame Options 50mm Standard 30mm NA BEC EPC = = = Natural Anodised Baked Enamal Colour Epoxy Powder Coating

Finish Options

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for opening size into which grille will fIt If Code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange.

WEATHER LOUVRES
Type - WPL

03

TYPE WL

Weather Louvre manufactured of extruded Type 50S anodising grade aluminium. The ftxed horizontal blades are held in place by screws. Blades are spaced 50mm apart. = WM OBD PC FS = = Top Blade fits flush with frame. Lip of Bottom Blade overlap frame. Wire Mesh Opposed Blade Damper NOTE: Adjustment from face of
Louvre is not advisable.

Standard Spacing Accessories

= = =

Punched Counter Sunk Holes Rear Fixing Straps Normal Duct Size

Dimensions Notes

ON

1) Alternative Meshes available on request. 2) For Weather Louvres smaller than 450 x 300 we recommend the use of Type RA with RARB Blade with19mm spacing.

TYPE WL: WEATHER LOUVRE Vermin Protection: - Plastic Bird mesh - Standard - Galvanised wire mesh Finish Options NA BEC EPC = = = Natural Anodised Baked Enamal Colour Epoxy Powder Coating

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for ON size If Code "OS" is entered under SPECIAL INSTRUCTIONS, then dimensions given are over flange

WEATHER LOUVRES
Type - WL

04

100 90 80 70 60 50 40 30 25 20 15

10 9 8 7 6 5 4 3 2.5 2 1.5 I Intake Air

II Reject Air

10 8 1.25 0.05 0.06 0.07 0.08 0.09 0.1 0.12 0.14 0.16 0.18 0.2 0.25 0.3
20

1.5

2.5

3.5

m/s

NR

0.025 0.03 0.035 0.04 0.045 0.05 0.06 0.07 0.08 0.09 0.1 0.12 0.14 0.16 0.18 0.2 0.25 0.3 0.35 0.4 0.5 0.6 0.7 0.8 0.9 1
40 45 50 55

0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.2 1.4 1.6 1.8 2 2.5 3
30

25

4 5 6 7 8 9 10 m3/s

35

1.2 1.4 1.6 1.8 2 2.5

3.75

3.5

m2

COMMITMENT IS THE DIFFERENCE

FLOOR GRILLES
technical

type - FG

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

FLOOR GRILLES
Type - FG

02

TYPE FG

Floor Grille manufactured of extra heavy section extruded Type 50S anodising grade aluminium. Grille cores are easily removable. Generally used in raised computer room floors. PB OBD = = Plenum Box Opposed Blade Damper

Accessories

Frame

Finish Options

NA = BEC = EPC = NOTE:

Natural Anodised Baked Enamal Colour Epoxy Powder Coating PaintinglEpoxy Powder Coating of Type FG is n ot recommended.

Blade Options

TYPEFG O: 0 Blade

TYPE FG 15: 15 Blade

Blade Spacings

13mm Standard

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for opening size into which grille will fit, (i.e "OS" size of grille). If Type FG 0 or FG 15 required, enter under Type.

FLOOR GRILLES
Type - FG SELECTION DATA
37.5 1.5

03

1.0 0.9 0.8 0.7 0.6 300 0.5 0.4 10 0.3 0.25 5 0.2 4 5 3 0.15 2 4 3 2 1 0.1 0.09 0.08 0.07 0.06 0.05 0.5 0.4 0.04 0.3 Jet Velocity m/s 1 0.8 0.2 0.2 Extract Grille OBD - ADD 50% Supply Grille OBD - ADD 50% 0.5 0.5 1 162.5 175 187.5 200 212.5 225 237.5 250 262.5 275 287.5 300 312.5 325 Opening width mm 8 20 20 10 10 112.5 5 3 2 137.5 150 125 100 200 100 100 50 50 87.5 75 300 200 62.5 50

0.03 Air Flow m3 / s / metre lenght

Pressure N/m2

NOTES:
SELECTION DATA IS BASED ON m3/s/met. JET VELOCITY IS ACTUAL VELOCITY BETWEEN BLADES

EXAMPLE
SELECTION BASED ON 1 METRE LENGTH OF GRILLE FOR 0.25m3/s/met AND JET VELOCITY OF 3.6m/s USE 162.5mm WIDE GRILLE OR 0.165 SQ.MET.

COMMITMENT IS THE DIFFERENCE

OPPOSED BLADE DAMPER


technical types -OBD

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

OPPOSED BLADE DAMPER


Type - OBD

02

Determine the sound level which results from the combined effects of several sound sources is not as difficult as it is confusing. The NY data for diffusers given contains an allowance for the sound absorbing properties of the average room and its contents. This absorption is assumed to be 8 db with sound power level referenced to 10-12 Watts. (The absorption is 18 db referenced to 10-13 Watts)? For relatively small spaces - about 76.2m2 or less floor area and ceiling height of 3.0m or less the following simplified method for estimating NC levels produced by a combination of supply diffusers and return registers or grilles can be used: 1. Determine the difference in NC level between the supply outlets or return intakes having the highest NC and the second highest NC level. 2. From Table 9 determine the number of decibels to be added to the NY level of the unit having the highest NC level. This sum is the combined NC level generated by the two units. 3. If three units serve the space, determine the difference between the combined NC level of the first two units and the NC level of the third unit. Determine the NC addition as above, and add this to the combined NC level of the first two units. If the difference between NC levels of two units is 10 db or more, the sound generated by the quieter unit will not affect the space NC. EXAMPLE Two supply diffusers having an NC level of 30 and a return grille having an NC level of 35 serve a room. What is the combined NC level? SOLUTION The return has the highest NC level 35 db. The second highest is one of the diffusers at 30 db. The difference between them is 5 db. From Table 6, the NC addition for a 5 db difference is about one. Adding this to the higher NC gives a combined NC of 36.To take the second diffuser into consideration, follow the same procedure as above. The NC calculated above is 36. The NC of the diffuser is 30. The difference between them is 6. The NC addition for this difference is 1, and the combined effect of the two diffusers and the return grille is NC 37.

OPPOSED BLADE DAMPER


Type - OBD

03

TYFE OBD:

Opposed Blade Damper manufactured from extruded aluminiunm Blades. Blades are held in place by spring wire and starlock push on fix. The OBD blades are linked and lever or slot operated. OBD suits all standard grilles and diffusers.

BLADE OPTIONS: FINISH OPTIONS:

Standard as per sketch

PR MF BLADE SPACING:

= Primed Black (optional) = Mill Finish (standard)

25mm Standard

Ordering Procedure: Example

Note: (1) (2)

Dimensions given are for - To ftt ON of mother grille If OBD to ftt grille, indicate type of grille, outside neck size.

COMMITMENT IS THE DIFFERENCE

CONCEALED FIXINGS
technical

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

CONCEALED FIXINGS
Details

02

Concealed fixings come complete with a 100mm length of flange which serves as a duct cleat.

COMMITMENT IS THE DIFFERENCE

PLENUM BOX
technical types -PB

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

PLENUM BOX
Type - PB

02

PLENUM BOX TYPEPB

PLENUM BOX
Type - PB

03

TYPEPB

Plenum Box manufactured of Galvanised Flat Sheet with top or side entry spigot - Uninsulated or internally insulated with lOmm Thermaflex. Plenum Box usually fits over neck of Ceiling Diffuser. Spigot sizes have been selected using maximum neck velocity shown in our chart for each CD. i.e: 3.5m/sec. When ordering spigot diameter larger than those shown cannot be used , smaller can be specified.

All dimensions in mm. ORDERING PROCEDURE:

Example

Note: (1) (2)

Dimensions given are for Ceiling Diffuser Size. If insulated Plenum Box required - Enter under SPECIAL INSTRUCTIONS

COMMITMENT IS THE DIFFERENCE

CUSTOM MADE PRODUCTS


technical types -CM

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

CUSTOM MADE PRODUCTS


Type - CM

02

CUSTOM MADE TYPE CM

CUSTOM MADE PRODUCTS


Type - CM

03

TYPECM:

Custom Made products are fabricated of aluminium flat sheets and aluminium extruded sections, and are available with epoxy powder coating or baked enamel colour finish. Type CM products are designed to complement architectural and interior/exterior designs and are available on special request to your requirements.

COMMITMENT IS THE DIFFERENCE

PLASTIC DIFFUSERS
technical T-Bar Register, Surface Mounted Register, Side Wall Register

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

PLASTIC DIFFUSERS
T-Bar Register
T-BAR REGISTER MODEL: JM-602 FIXED CORE JM-602R REMOVABLE CORE SPECIFICATIONS Size: Outer frame either

02

595mm x 595mm metric 603mm x 603mm imperial. Neck 360mm x 360mm Material: Plastic, either ABS or HIPS, can have U.V Stabilizing and with or without fire retardant. It is important to check the price before selecting materials for production. Colour: Our colour is standard white however for large runs we are prepared to use other colours but there may be a cost penalty. ADVANTAGES Cost effective Less condensation than metal grilles Do not rust Easy to clean Light weight Range of black plastic neck adaptors to suit. TECHNICAL DATA Neck l/S 35 150 45 55 65 80 200 75 100 125 150 175 250 100 150 175 200 250

360x360 55 595x595 603x603


Neck 300 350 l/S 125 150 225 270 315 210 260 345 420 490 N.C. 22 24 29 33 39 21 25 30 34 39 pa 15 25 20 35 50 15 25 35 45 55 Throw 2.8 3.4 4.4 4.9 5.3 3.3 3.6 4.6 5.2 5.5

N.C. 7 14 20 24 11 18 24 28 10 14 18 26 30

pa 15 20 25 35 45 15 25 35 45 50 15 25 35 45 50

Throw 2.1 2.4 2.7 3.0 3.3 2.7 3.0 3.4 3.6 3.9 2.6 3.6 4.4 4.8 5.1

Black Plastic Neck Adaptors To Suit The Above Models Neck Adaptor Size A06 150dia 360mm x 360mm A08 200dia 360mm x 360mm A10 250dia 360mm x 360mm A12 300dia 360mm x 360mm A14 350dia 360mm x 360mm

PLASTIC DIFFUSERS
T-Bar Register
T-BAR REGISTER MODEL: MC-24 FIXED BLADES MC-24A ADJUSTABLE BLADES SPECIFICATIONS Size: Outer frame either 595mm x 595mm metric 603mm x 603mm imperial. Neck 500mm x 500mm Material: Plastic, either ABS or HIPS, can have U.V Stabilizing and with or without fire retardant. It is important to check the price before selecting materials for production. Colour: Our colour is standard white however for large runs we are prepared to use other colours but there may be a cost penalty.

03

450x450
ADVANTAGES Cost effective Less condensation than metal grilles Do not rust Easy to clean Light weight TECHNICAL DATA l/S 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1050 1100 1150 1200 NR 22 22 22 24 26 28 30 32 34 36 36 37 37 38 38 40 42 44 44 46 48 50 50 pa 0 0 1 2 3 4 5 7 9 11 12 14 17 19 21 23 26 28 31 34 37 40 45 Throw/1 Way 1.0 2.0 3.3 3.6 3.7 3.9 4.3 4.4 4.5 4.6 4.8 4.9 5.0 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.8 5.9 5.9 Throw/2 Way 0.8 1.0 2.4 3.0 3.2 3.4 3.6 3.8 3.9 4.1 4.2 4.3 4.3 4.4 4.4 4.5 4.5 4.6 4.6 4.7 4.7 4.8 4.8 Throw/3 Way 0.5 1.0 1.8 2.1 2.2 2.3 2.4 2.6 2.8 2.8 2.9 2.9 3.0 3.0 3.2 3.2 3.3 3.3 3.4 3.4 3.5 3.6 3.6

595x595 603X603

55

PLASTIC DIFFUSERS
Surface Mounted Register
SURFACE MOUNTED REGISTER MODEL: MC-300 ADJUSTABLE BLADES MC-370 ADJUSTABLE BLADES SPECIFICATIONS Material: Plastic, either ABS or HIPS, can have U.VStabilizing and with or without fire retardant. It is important to check the price before selecting materials for production. Colour: Our colour is standard white however for large runs we are prepared to use other colours but there may be a cost penalty. ADVANTAGES Cost effective Less condensation than metal grilles Do not rust Easy to clean Light weight Range of black plastic neck adaptors to suit..

04

300x300 65 365x365 370x370 65 435x435

TECHNICAL DATA MC-300 ADJUSTABLE BLADES SET AT 45 l/S 75 150 200 250 300 350 400 450 NR 17 23 35 41 46 49 53 pa 1 4 8 15 23 33 44 54 Throw/1 Way 2.4 3.6 4.6 5.3 5.8 6.0 6.2 6.4 Throw/2 Way 2.0 3.0 3.8 4.4 5.0 5.2 5.3 5.5

Throw/4 Way 1.4 2.2 2.7 3.2 3.5 3.5 3.7 3.8

MC-370 ADJUSTABLE BLADES SET AT 45 l/S 150 200 250 300 350 400 450 500 550 NR 21 27 33 38 45 51 53 55 pa 2.5 5.0 9.0 16 22 28 36 44 50 Throw/1 Way 1.8 3.4 4.3 4.6 5.0 5.3 5.4 5.5 5.7 Throw/2 Way 1.5 2.8 3.6 4.0 4.2 4.4 4.5 4.7 4.8 Throw/4 Way 1.0 2.0 2.6 2.9 3.0 3.2 3.4 3.5 3.6

PLASTIC DIFFUSERS
Surface Mounted Register

05

SURFACE MOUNTED REGISTER MODEL: MC-555 ADJUSTABLE BLADES

SPECIFICATIONS Size: Outer frame 620mm x 435mm Neck 555mm x 370mm Material: Plastic, either ABS or HIPS, can haveU.V. Stabilizing and with or without fire retardant. It is important to check the price before selecting materials for production. Colour: Our colour is standard white however for large runs we are prepared to use other colours but there may be a cost penalty. ADVANTAGES Cost effective Less condensation than metal grilles Do not rust Easy to clean Light weight Range of black plastic neck adaptors to suit.

555x370 65 620x435

TECHNICAL DATA ADJUSTABLE BLADES SET AT 45

l/S 150 200 250 300 350 400 450 500 550 600 650

NR 21 27 33 39 46 47 49 50 52

pa 2 4 7 11 16 22 28 36 44 54 64

Throw 1/Way 1.8 3.4 4.3 4.6 5.0 5.3 5.4 5.6 5.8 6.0 6.0

Throw 2/Way 1.5 2.8 3.6 4.2 4.4 4.5 4.7 4.8 4.9 5.0 5.1

PLASTIC DIFFUSERS
Side Wall Register

06

SIDE WALL REGISTER MODEL: JM-608 ADJUSTABLE BLADES JM-6060 ADJUSTABLE BLADES JM-6080 ADJUSTABLE BLADES

SPECIFICATIONS Material: Plastic, either ABS or HIPS, can have V.v. Stabilizing and with or without fire retardant. It is important to check the price before selecting materials for production. Colour: Our colour is standard white however for large runs we are prepared to use other colours but there may be a cost penalty. ADVANTAGES Cost effective Less condensation than metal grilles Do not rust Easy to clean Light weight

C X D 40 A X B
Dim C 700 mm 600 mm 800 mm Dim D 120 mm 120 mm 120 mm

TECHNICAL DATA Model JM-608 JM-6060 JM-6080 Dim A 740 mm 630 mm 830 mm Dim B 170 mm 170 mm 170 mm

PLASTIC DIFFUSERS
Multiround Jet Diffuser

07

MULTIROUND JET DIFFUSER TECHNICAL DATA Description Velocity (m/s) 150mm Plastic 2 (Cold Air) 3 4 MJ-06 5 6 Description Velocity (m/s) 200mm Plastic 2 (Cold Air) 3 4 MJ-08 5 6 Description Velocity (m/s) 250mm Plastic 2 (Cold Air) 3 4 MJ-10 5 6 Description Velocity (m/s) 300mm Plastic 2 (Cold Air) 3 4 MJ-06 5 6 7 Volume (m 3/s) 0.030 0.046 0.062 0.083 0.107 Volume (m 3/s) 0.058 0.086 0.113 0.140 0.180 Volume (m 3/s) 0.089 0.136 0.187 0.238 0.273 Volume (m 3/s) 0.131 0.200 0.277 0.353 0.416 0.490 NC 26 30 36 43 49 NC 27 30 36 44 50 NC 24 26 33 42 49 NC 24 29 33 36 43 47

PLASTIC DIFFUSERS
Multiround Cone Diffuser

08

MULTI ROUND CONE DIFFUSER TECHNICAL DATA Description Velocity (m/s) 150mm Plastic 2 (Cold Air) 3 4 MC-06 5 6 Description Velocity (m/s) 200mm Plastic 2 (Cold Air) 3 4 MC-08 5 6 Description Velocity (m/s) 250mm Plastic 2 (Cold Air) 3 4 MC-10 5 6 Description Velocity (m/s) 300mm Plastic 2 (Cold Air) 3 4 MC-12 5 6 Volume (m 3/s) 0.023 0.030 0.043 0.052 0.081 Volume (m 3/s) 0.042 0.059 0.077 0.111 0.140 Volume (m 3/s) 0.060 0.100 0.143 0.197 0.241 Volume (m 3/s) 0.120 0.180 0.252 0.320 0.415 NC 28 30 36 42 54 NC 29 33 39 44 48 NC 25 29 34 43 51 NC 25 29 35 39 45

COMMITMENT IS THE DIFFERENCE

METAL DIFFUSERS
technical T-BAR Regsiter Surface Mounted Jet Diffuser

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

METAL DIFFUSERS METAL DIFFUSERS

T-Bar Register Details

02 02

T-BAR REGISTER MODEL: JM-602M REMOVABLE CORE SPECIFICATIONS Size: Outer frame either 595mm x 595mm metric Neck 450mm x 450mm Material: Pressed Metal - Steel - Powder Coated Colour: Standard white but for large numbers we are prepared to use other colours, but there may be a cost penalty. ADVANTAGES Lightweight No visible joints on face Reduces possibility of corrosion Easy to clean Captive air system, no air leak to ceiling space

TECHNICAL DATA

450x450 55 595x595

l/S 100 150 200 250 300 400 500 600 700

l/S NR 100 150 200 250 22 300 24 400 26 500 32 600 36 700 42

NRpa pa Throw Throw - - 1.0 1.0 - - 1.4 1.4 - - 1.8 1.8 22 5 5 2.3 2.3 24 10 103.5 3.5 26 15 155.5 5.5 32 25 256.3 6.3 36 35 356.9 6.9 42 45 457.2 7.2

METAL DIFFUSERS
Surface Mounted Jet Diffuser

03

SURFACE MOUNTED JET DIFFUSER MODEL: JQJ-lS / JQJ-20 / JQJ-2S / JQJ-30

SPECIFICATIONS Material: Metal Spun Aluminium - uncoated. ADVANTAGES Light Weight Adjustable Air flow Integral Damper blade Excellent throw

Model JQ J-15 JQ J-20 JQ J-25 JQ J-30

Size Outer Frame A dia di a 180 di a 230 di a 280 di a 330

Neck B dia 150mm di a 200mm di a 200mm di a 300mm di a

A B

Neck Size Velocity 150 Volume (l/s) Throw (m) NC 200 Volume (l/s) Throw (m) NC 250 Volume (l/s) Throw (m) NC 300 Volume (l/s) Throw (m) NC

2 36 2.6 64 3.8 101 4.6 146 5.6 -

3 54 4.0 26 97 5.6 26 152 7.0 24 219 8.4 24

4 72 5.5 30 129 7.4 30 202 9.5 28 292 11.2 29

5 90 5.8 36 161 9.2 36 253 11.6 33 365 14.0 33

6 110 8.2 43 194 11.0 43 304 13.8 38 436 16.8 38

7 127 9.6 49 226 13.0 49 355 16.2 42 511 19.5 42

10 8 145 181 11.0 15.2 56 53 259 314 14.7 20.5 56 53 405 506 18.5 25.4 50 46 584 737 22.2 31.0 50 46

45

45

COMMITMENT IS THE DIFFERENCE

LINEAR AIR DIFFUSERS


technical Sound Level - Air -DD, SD types Supply

Europair Africa (Pty) Ltd


(a div. of First Strut)

tel +27 11 974 2425 fax +27 11 974 2443 web www.europair-africa.com email: info@europar.co.za

Cnr. Grader and Vuurslag Spartan Ext. 3 Kempton Park Johannesburg

LINEAR AIR DIFFUSERSDIFFUSERS LINEAR AIR


SOUND LEVEL- SUPPLY AIR

Sound Level - Supply Air Details

02 02

Opening Width mm Height mm Opening M3/s 0.005 0.007 0.009 0.011 0.014 0.018 0.023 0.028 0.037 0.047 0.056 0.066 0.075

944 20 1-slot 21 26 30 37 -

944 40 2-slot 26 29 33 40 -

944 60 3-slot 28 33 37 42 -

944 80 4-slot 29 32 36 40 43

Please note: Sound level given measured 1.5m away based on 1,2m length. For NC sound ratings: Subtract 6 from readings above. dba Corrections for various lengths: 300mm minus 4 600mm minus 3 900mm minus 1 1500mm plus 1 1800mm plus 2

HORIZONTAL DISCHARGE - THROW (METRES) Opening Width mm Height mm Opening M3/s 0.005 0.007 0.009 0.011 0.018 0.023 0.028 0.037 0.047 0.056 0.066 0.075 944 20 1-slot Throw 100% open 1.22 2.13 2.74 3.35 3.96 6.71 944 20 1-slot Throw 50% open 1.52 2.74 3.96 4.88 5.79 9.76 944 40 944 40 944 60 944 60 944 80 944 80

2-slot 2-slot 3-slot 3-slot Throw Throw Throw Throw 100% open 50% open 100% open 50% open 0.91 1.22 1.52 1.83 2.13 2.44 0.91 1.52 2.74 3.35 1.52 2.13 3.05 3.66 1.83 2.44 5.18 6.40 2.74 3.96 6.10 7.32 3.35 5.18 8.23 9.76 5.18 6.10 5.79 7.32 7.01 8.84 -

4-slot 4-slot Throw Throw 100% open 50% open 1.22 1.83 1.52 2.13 2.74 3.35 3.05 3.96 4.27 5.18 5.18 6.40 6.10 7.62 7.32 9.15 8.54 10.37

1. Throw based upon 1m length of diffuser. 2. For continuous lengths add 10% to above figures. 3. Above data for 1-way air pattern. 4. For 2-way air pattern consider each direction as a separate unit