Professional Documents
Culture Documents
Reprinting, (even in excerpts) requires our express approval. All rights reserved. All dimensions in mm. Subject to design changes. 2 Technical Manual: Industrial Folding Doors 06.2009
Contents
Topic
Page
Door selection guide Folding door FSN/FAW (nger trap protection) Steel folding door FSN, standard prole Aluminium folding door FAW, with thermal breaks FSN/FAW design examples FSN/FAW/FPU/FMI oor details Head details for FSN/FAW, tting to the wall, 90 opening, view I I (see page 5) Head details for FSN/FAW, tting in the opening, 90 opening, view I I (see page 5) Wicket door FSN/FAW Divided trafc leaf FSN/FAW Folding door FPU/FMI, double-skinned FPU with PUR insulation FMI with mineral wool insulation Ventilation slots FPU/FMI Head details for FPU/FMI, tting to the wall, 90 opening, view D D (see page 12) Head details for FPU/FMI, tting in the opening, 90 opening, view D D (see page 12) Glazings FPU Glazings FMI Wicket door FPU/FMI Divided trafc leaf FPU/FMI Sideroom FSN/FAW, view A A (see page 5) Sideroom FSN/FAW, tting to the wall, no passage loss, 90 Sideroom FSN/FAW, tting to the wall, no passage loss, 180 Sideroom PU/FMI, view A A (see page 12) Sideroom FPU/FMI, tting to the wall, no passage loss, 90 Sideroom FPU/FMI, tting to the wall, no passage loss, 180 Choice of folding arrangements/passage width for 3 and 5-leaf doors, FSN/FAW/FPU/FMI Choice of folding arrangements/passage width for 3 to 12-leaf doors, FSN/FAW/FPU/FMI FSN/FAW/FPU/FMI operator type AFT B900 - folding arrangement 0:2 or 2:0 FSN/FAW/FPU/FMI operator type AFT B900 - folding arrangement 2:2 Rain canopy/headroom, opening angle 90, FSN/FAW/FPU/FMI Rain canopy/headroom, opening angle 180, FSN/FAW/FPU/FMI Fire station folding door FSN/FAW/FPU/FMI, fast opening via a mechanical opening aid Fire station folding door FSN/FAW/FPU/FMI, fast opening via a mechanical opening aid Notes
4 5
6 7 8 9 10 11 12
13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34
Version
FSN
Sheet steel 1.5 mm Glazing types between 3 36 mm (*) Insulated glass 26 36 mm PU panel 26 mm Polyurethane (*)
KS
Between 3.5 W/m2 K and 3.7 W/m2 K Between 2.0 W/m2 K and 2.3 W/m2 K Between 1.5 W/m2 K and 1.8 W/m2 K Between 1.6 W/m2 K and 1.9 W/m2 K
FAW
KS
Approx. 28 dB/(A)
FPU doubleskinned
KS
Surfacemounted
Approx. 22 dB/(A)
FMI doubleskinned
*
KS
Surfacemounted
Approx. 24 dB/(A)
Fire station folding door with folding arrangement 2:2 (see pages 32 33) Size range for manually operated doors
6000 5000
RAM height
4500 4000 3500 3000 2500 Approx. 5200 Approx. 8000 Approx. 3500 Approx. 14000 4000
RAM width
6000 5000
RAM height
4500 4000 3500 3000 2500 Approx. 5200 Approx. 5600 Approx. 8000 Approx. 3500 Approx. 14000 4000
RAM width Fully glazed Max. RAM 4000 x 4000 Fire station Max. RAM 5200 x 5000 FPU Leaf width max. 1400 FMI Leaf width max. 1400 FSN Leaf width max. 1400 FAW Leaf width max. 1300
Steel Folding Door FSN (Standard Prole) with Finger Trap Protection Aluminium Folding Door FAW (with thermal breaks) with Finger Trap Protection
Folding door, 3-leaf version
Tubular guide rail Track roller Intermediate, adjustable aluminium diecast hinge
Surfacemounted espagnolette lock, prepared for prole cylinder with lever handle set
FFL
Elastic trap protection proles on the vertical leaf edges ensure accident-free operation and also reduce noise.
Fixing of the open door leaves via a drop bolt. Wall hold-open device on request.
LDB (90)
Note: Do plaster and screed work after door tting. Folding arrangements and clear passage dimensions, see pages 26 27. With/without ventilation slots
= = = =
Overall frame dimension Clear width Clear passage width Top edge of nished oor level
FSN
Max. 1250
Max. 4000
Max. 5000
Max. 2375
Max. 3000
FSN: View K K Smooth sheet steel Single pane Insulated pane Special inll
Min. 1.5 mm
Max. 6 mm
26 mm or 36 mm
Min. 18 mm to max. 36 mm
Min. 26 mm to max. 36 mm
PU panel Max. 26 mm
Max. 6000
INTERIOR
EXTERIOR
L 120 x 80 x 8
FFL 26
130
15 150 Recess 130 x 150 Leave free until after tting INTERIOR EXTERIOR FFL On-site internal water run-off 94
15
Head Details for FSN/FAW Fitting to the Wall, 90 Opening View I I (see page 5)
Sideroom overview, see pages 20 22 90 headroom overview, see page 30 180 headroom overview, see page 31 External tting Internal tting
135
135
Min. 95
Min. 60
20
20
RAM = LH + 106
RAM = LH + 80
Min. 60 LDH = LH 26
LH = LDH
Min. 95 INTERIOR EXTERIOR INTERIOR EXTERIOR 30 x 68 x 50 15 FFL 26 FFL 15 30 x 68 x 50 100 100 50 50 On-site recess 150 On-site internal water run-off 150
RAM LH LDH FFL = = = = Overall frame dimension Clear height Clear passage height Top edge of nished oor level
On-site recess
Doors on the weather side are preferably tted externally! Threshold required as a guide. 3 and 4-leaf doors also without a threshold on request On-site internal water run-off required.
LH
Head Details for FSN/FAW Fitting in the Opening, 90 Opening View I I (see page 5)
Sideroom overview, see pages 20 22 90 headroom overview, see page 30 180 headroom overview, see page 31 External tting
135 Min. 60 Min. 60
Internal tting
135 Min. 60 Min. 60
15
15
15
15
RAM = LH + 26 15
RAM = LH 15
LH
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
30 x 68 x 50 30 x 68 x 50 15 FFL 26 FFL 15
On-site recess
100
100
50
50
On-site recess
150
150
Doors on the weather side are preferably tted externally! Threshold required as a guide. 3 and 4-leaf doors also without a threshold on request On-site internal water run-off required.
= = = =
Overall frame dimension Clear height Clear passage height Top edge of nished oor level
26
LH
A wicket door must be provided for folding doors without a trafc leaf (locking leaf), i.e. those with folding arrangements 2:2, 2:4, 4:4, etc. and without a second entrance. An outward-opening escape door may also be required by the authorities.
Wicket door height (note horizontal rail division for the door leaf!)
60
70 = rail 60 90 = rail 80
FFL
30
FFL
110
110
Backset 40
Note: The wicket door is adjusted to match the appearance of the door version.
= Clear passage width = Clear passage height = Top edge of nished oor level
10
30
Divided trafc leaves (lock leaves) do not have an obstructive threshold rail as with wicket doors. They are recommended for door heights above 3500 mm and in windy areas (with manual operation). They also reduce loss of heat. Divided trafc leaves enable a larger passage width and barely impair the overall appearance of the door.
Detail
Track roller Tubular guide rail
Detail
Surface-mounted espagnolette lock, prepared for prole cylinder, with lever handle set
FFL
FFL
11
Steel Folding Door FPU/FMI, Double-Skinned FPU with PUR Insulation FMI with Mineral Wool Insulation
FPU: Door leaf with PUR insulation approx. 60 mm thick (textured on both sides or smooth sheet steel) FMI: Door leaf with mineral wool insulation approx. 60 mm thick (1.50 mm thick smooth sheet steel on both sides) Door leaf, guide rail and frame hot galvanized and wet primer-coated. Finger trap protection consisting of a hollow rubber prole between the individual door leaves and side frame. Top lip seal, bottom brush seal.
View D D See pages 14 15 Elastic trap protection proles on the vertical leaf edges ensure accident-free operation and also reduce noise.
1050 from FFL
Surfacemounted espagnolette lock, prepared for prole cylinder, with lever handle set
FFL D
Fixing of the open door leaves via a drop bolt. Wall hold-open device on request.
LDB (90)
Note: Do plaster and screed work after door tting. Folding arrangements and clear passage dimensions, see pages 26 27. Without ventilation slots With ventilation slots with/without sliding cover 12
= = = =
Overall frame dimension Clear width Clear passage width Top edge of nished oor level
Free ventilation cross section: 3 ventilation slots form one group = 12 cm2, several groups can be arranged next to or on top of each other. Interior sliding cover possible.
Min. 180 80
Min. 180
Min. 80
Min. 80
30
13
Head Details for FPU/FMI Fitting to the Wall, 90 View D D (see page 12)
Sideroom overview, see pages 23 25 90 headroom overview, see page 30 180 headroom overview, see page 31 External tting Internal tting
135
135
Min. 95
85 x 60
85 x 60
Min. 60
20
15
15
Insulation
Insulation
RAM = LH + 106
RAM = LH + 80
INTERIOR
EXTERIOR
60
On-site recess
150
50
With insulation Doors on the weather side are preferably tted externally! Threshold required as a guide. 3 and 4-leaf doors also without a threshold on request On-site internal water run-off required.
RAM LH LDH FFL = = = =
Without insulation
Overall frame dimension Clear height Clear passage height Top edge of nished oor level
14
LDH = LH -26 LH
LH = LDH
Min. 95
Head Details for FPU/FMI Fitting in the Opening, 90 Opening View D D (see page 12)
Sideroom overview, see pages 23 25 90 headroom overview, see page 30 180 headroom overview, see page 31 External tting Internal tting
15
15 Insulation
15
85 x 60
85 x 60
Insulation
RAM = LH + 11
RAM = LH 15
15
LDH = LH -121
LH
LDH = LH 95
INTERIOR
EXTERIOR
INTERIOR
EXTERIOR
30 x 68 x 50 15 30 x 68 x 50 15 FFL 26 FFL
100
100
50
50
On-site recess
With insulation Doors on the weather side are preferably tted externally! Threshold required as a guide. 3 and 4-leaf doors also without a threshold on request On-site internal water run-off required.
RAM LH LDH FFL = = = =
Without insulation
Overall frame dimension Clear height Clear passage height Top edge of nished oor level
26
LH
15
Glazings FPU
Glazing frame in rounded version, arrangement of glazing in the partial surface Plastic as standard, metal on request Preferably in the standard sizes (clear view 473, 523, 573 mm wide, each 773 mm high, Duratec synthetic double pane 26 mm) including clear Duratec acrylic double pane or double-moulded pane 20 mm Other single panes from 3 to 6 mm or insulated panes up to 26 mm thick are possible on-site. Special sizes available up to max. 1250 mm high. Single pane View E E Insulated pane View F F
Standard
Special size
773
Max. 6
Min. 208
Min. 208
2000
Divided trafc leaf Leaf section A = Min. 1300 to H = 3000 Min. 1400 to H = 3500 Min. 1500 to H = 4000 Min. 1600 to H = 4500 Min. 1700 to H = 5000 a = min. surrounding area 180 Black glazing frame as a clamping prole with clear Duratec synthetic single pane 3 mm or Duratec polycarbonate pane 6 mm or Duratec synthetic double pane 26 mm.
16
370
Min. 208
Glazings FMI
Glazing frame in rounded version, arrangement of glazing in the entire surface Plastic as standard, metal on request Preferably in the standard sizes (clear view 473, 523, 573 mm wide, each 773 mm high, Duratec synthetic double pane 26 mm) including clear Duratec acrylic double pane or double-moulded pane 20 mm. Other single panes from 3 to 6 mm or insulated panes up to 26 mm thick are possible on-site. Special sizes available up to max. 1250 mm high. Single pane View G G
Standard
Special size
773
Min. 1250
Max. 6
min. 108
Min. 300
2000
Divided trafc leaf Black glazing frame as a clamping prole with clear Duratec synthetic single pane 3 mm or Duratec polycarbonate pane 6 mm or Duratec synthetic double pane 26 mm.
370
Min. 108
17
A wicket door with threshold must be provided for folding doors without a trafc leaf (locking leaf), i.e. those with folding arrangements 2:2, 2:4, 4:4 etc. and without a second entrance (on request also without a threshold for type FMI with folding arrangments 1:2, 2:1, 2:2). An outward-opening escape door may also be required by the authorities. With PUR doors a wicket door can only be included from a door height of 3500 mm, and should usually be tted in the door leaf without glazing cut-out.
Exterior rain canopy EPDM seal 2-piece aluminium hinge, black, screwed Black aluminium edge
FFL
40
Backset 65
Note: The wicket door is adjusted to match the appearance of the door version.
= Clear passage width = Clear passage height = Top edge of nished oor level
18
Divided trafc leaves (lock leaves) do not have an obstructive threshold rail as with wicket doors. They are recommended for door heights above 3500 mm and in windy areas (with manual operation). They also reduce loss of heat. Divided trafc leaves enable a larger passage width and barely impair the overall appearance of the door.
Detail
Track roller Tubular guide rail
Detail
Surface-mounted espagnolette lock, prepared for prole cylinder, with lever handle set
FFL
FFL
19
90 Min. 60 10 20
LB 10
70
LB
85 x 60
Min. 60
85
85 x 60
Fitting to the wall Free passage width with 180 opening angle
LB 10 10
Min. 120 85
LB
Min. 60
50 85 x 60 85 x 60
Min. 60
RAM = LB 20
RAM = LB + 220
RAM LB
20
Head details overview, see pages 8 9 Folding arrangement overview, see pages 26 27
RAM LB
21
135
120
365
275
LB
120
135
135
120
605
495
LB
120
135
Head details overview, see pages 8 9 Folding arrangement overview, see pages 26 27
715
RAM LB
22
135
135
90 Min. 60 10 20
LB 70 10 LB
85 x 60
85 Min. 60
85 x 60
RAM = LB + 160
RAM = LB + 120
Fitting to the wall Free passage width with 180 opening angle
Min. 140 10 LB 10 85
LB
Min. 60
70
85 x 60 Min. 60 85 x 60
RAM = LB 20
RAM = LB + 260
RAM LB
23
Head details overview, see pages 14 15 Folding arrangement overview, see pages 26 27
RAM LB
24
135
135
365
275
605
495
135
Head details overview, see pages 14 15 Folding arrangement overview, see pages 26 27
715
RAM LB
135
135
135
25
no second entrance.
RAM - 590
RAM - 240
RAM - 280
1:2
RAM - 590
RAM - 240
RAM - 280
2:1
RAM - 565
RAM - 215
RAM - 200
3:00
RAM - 565
RAM - 215
RAM - 200
00:3
RAM - 720
RAM - 240
RAM - 280
1:3
RAM - 720
RAM - 240
RAM - 280
3:1
RAM - 680
RAM - 240
RAM - 280
2:2
RAM - 655
RAM - 215
RAM - 200
00:4
RAM - 655
RAM - 215
RAM - 200
4:00
RAM - 810
RAM - 240
RAM - 280
2:3
RAM - 810
RAM - 240
RAM - 280
3:2
RAM - 810
RAM - 240
RAM - 280
4:1
RAM - 785
RAM - 215
RAM - 200
00:5
26
FAW FSN
FPU FMI
Folding doors without a trafc leaf: A wicket door is required if there is no second entrance. Not possible with FAW
RAM - 940
RAM - 240
RAM - 280
3:3
RAM - 940
RAM - 240
RAM - 280
3:3
RAM - 900
RAM - 240
RAM - 280
2:4
RAM - 1030
RAM - 240
RAM - 280
3:4
RAM - 1030
RAM - 240
RAM - 280
4:3
RAM - 1120
RAM - 240
RAM - 280
4:4
RAM - 1250
RAM - 240
RAM - 280
4:5
RAM - 1250
RAM - 240
RAM - 280
5:4
RAM - 1380
RAM - 240
RAM - 280
5:5
RAM - 1380
RAM - 240
RAM - 280
5:5
RAM - 1470
6:5
RAM - 1470
5:6
RAM - 1560
6:6
27
Operator
Operator
RAM
RAM
80
= = = = = =
Overall frame dimension Clear height Clear width Clear passage width Clear passage height Top edge of nished oor level
28
330
LH
Operator
Operator
Operator
1050
LDH = LH approx. 95
RAM
LH
FFL
RAM
330
80
330
80
170
80
Approx. 360
Approx. 370
= = = = = =
Overall frame dimension Clear height Clear width Clear passage width Clear passage height Top edge of nished oor level
80
170
29
Approx. 170
Approx. 270
190 165
120
190 165 80
120
Cover 3
Approx. 435 Approx. 270 Approx. 270
295
210
270
120
Operator
INTERIOR
EXTERIOR
Rain canopy length: RAM + approx. 100 mm Type of tting Without rain canopy To the interior wall To the exterior wall In the opening In the opening Fire station folding door 95 95 160 170 Headroom [mm] With rain canopy 200/200 on request on request -
Applies to FSN folding arrangements: 1:2/2:1/2:2/2:3/3:2/2:4/4:2/2:5/5:2 Applies to FAW folding arrangements: 1:2/2:1/2:2/2:3/3:2/2:4/4:2/2:5/5:2
30 Technical Manual: Industrial Folding Doors 06.2009
120
60
Approx. 450
295
270 210
INTERIOR
EXTERIOR
Canopy 5
Approx. 660
315
290
210
115
INTERIOR
EXTERIOR
Rain canopy length: RAM + approx. 300 mm Type of tting Without rain canopy On the wall In the opening 240 160 Headroom [mm] With rain canopy 310/330 -
80
31
Fire Station Folding Doors FSN/FAW/FPU/FMI Fast Opening via a Mechanical Opening Aid
Fast opening via pre-tensioned opening aids with sound absorber. Folding arrangement 2:2. Opening angle 90. Release via pull cord. Supplemented with lifting magnet. On-site connecting lead. The quick release can be operated on the left or right (right arrangement shown). The release with pull cord can be supplemented by a lifting magnet and is triggered via a push button. Group switching possible.
Without trafc leaf (locking leaf). Can only be opened from inside (second entrance required).
FFL
1520
60 x 85
INTERIOR Min. 170 Folding arrangement 2:2, opening angle 90 Space requirement = LB + 800 (min. 4300)
= = = =
Overall frame dimension Clear width Clear passage width Top edge of nished oor level
DIN 14092 part 2 stipulates doors opening inwards and requires a minimum passage dimension of 3500 mm width and 3500 mm or 4000 mm height. Due to the leaf packs when the door is open, larger opening dimensions may be required, depending on the door, see also folding arrangement 2:2 on page 26. In exceptional cases involving renovations, doors opening outwards are also available, notwithstanding DIN.
32
Fire Station Folding Doors FAW/FPU/FMI/FSN Fast Opening via a Mechanical Opening Aid
Fast opening via pre-tensioned opening aids with sound absorber. Folding arrangement 2:2. Opening angle 90. Release via pull cord. Supplemented with lifting magnet. On-site connecting lead. The quick release can be operated on the left or right (right arrangement shown). The release with pull cord can be supplemented by a lifting magnet and is triggered via a push button. Group switching possible.
15
60x85
15
60x85
140
Min. 60
60x85
120
15
60x85
RAM = LH + 140
EXTERIOR
INTERIOR
EXTERIOR
INTERIOR
25
15
25
FFL
15
RAM = LH -15
FFL
Min. 60 Min. 60
Detail A See page 30 FAW FSN with insulation FSN without insulation
120
60x85 60x85 RAM LH LDH FFL = = = = Overall frame dimension Clear height Clear passage height Top edge of nished oor level
10
DIN 14092 part 2 stipulates doors opening inwards and requires a minimum passage dimension of 3500 mm width and 3500 mm or 4000 mm height. Due to the leaf packs when the door is open, larger opening dimensions may be required, depending on the door, see also folding arrangement 2:2 on page 26. In exceptional cases involving renovations, doors opening outwards are also available, notwithstanding DIN.
33
Notes
34
Notes
35
Hrmann KG Amshausen
Hrmann KG Antriebstechnik
Hrmann KG Brandis
Hrmann KG Brockhagen
Hrmann KG Dissen
Hrmann KG Eckelhausen
Hrmann KG Freisen
Hrmann KG Ichtershausen
Hrmann KG Werne
Hrmann is the only manufacturer worldwide that offers you a complete range of all major building products from one source. We manufacture in highly-specialized factories using the latest production technologies.
GARAGE DOORS
OPERATORS
INDUSTRIAL DOORS
LOADING EQUIPMENT
The close-meshed network of sales and service companies throughout Europe, and activities in the USA and China, make Hrmann your strong partner for first-class building products, offering Quality without Compromise.
HINGED DOORS
DOOR FRAMES