You are on page 1of 12

TRX228 - 10 function AC mini receiver TRX229 - 2 function AC micro receiver

INSTALLATION INSTRUCTIONS INS00054 Issue 8

CONTENTS

PAGE

Important Notes / Preventative Maintenance .............................................................................. 1 General Description / Contents Of Box ....................................................................................... 2 Telemetry Options/ RS485 Network Termination ....................................................................... 3 Fitting Optional Telemetry Sub-board / Connection Details ........................................................ 4 Cable Recommendations / Cable Glands / Fuse Ratings........................................................... 4 Supply Inputs / Circuit Description .............................................................................................. 5 Receiver Layout ~ TRX229 ......................................................................................................... 5 Receiver Layout ~ TRX228 ......................................................................................................... 6 4 to 3 Wire Lens Converter Connections .................................................................................... 7 Pan & Tilt Unit Connections / Video & Telemetry Connections................................................... 8 Test Modes ................................................................................................................................. 8 Setting Receiver Address............................................................................................................ 9 Troubleshooting .......................................................................................................................... 9 Specifications ............................................................................................................................ 10

Before attempting to connect or operate this product, please read these instructions completely
It is recommended that this unit is installed in accordance with the latest national standards: IEE Regulations for Electrical Installation, BS 7671. If this equipment is to be operated in Sub-zero temperatures, ARCTIC GRADE PVC CABLE must be used. Refer to cable manufacturers specifications for operating temperatures, etc.

Molynx Videmech, Albany Street, Newport, South Wales, United Kingdom, NP20 5XW. Tel: +44 (0)1 633 821000, Fax : +44 (0)1 633 850893, Email : sales@molynx.co.uk
Whilst every effort has been made to ensure that all information contained in this document is correct at the time of publication, due to our policy of continuous product improvement, the company reserves its right to change any information contained herein without notice. Molynx Videmech is a division of Bewator Group Limited.

Important Notes
SELECT SUITABLE EQUIPMENT! Please ensure that all equipment is suitable for the application and the environment for which it is intended. Ensure all applicable specifications are adhered to. Please take particular care that inter-connected equipment is fully compatible with each other and suitable for such use. Check load ratings, dimensions, etc. SECURELY MOUNT THE ASSEMBLY! This boxed unit must be properly and securely mounted. Care should be exercised to select suitable hardware to install the unit, taking into account both the composition of the mounting surface and the weight the surface will be required to sustain. Ensure that each part of the assembly is securely attached. Always use the recommended or supplied fixing screws. Failure to comply with the aforementioned could result in the unit coming loose from the supporting structure and falling, with resultant damages or injury to anyone or anything struck by the falling unit. INSTALL OUT OF REACH! This equipment is designed to be installed out of reach of the user, or anyone who will come into casual contact with the installation. Be sure to provide suitable access equipment to ensure the safety of installation or service personnel working on the equipment. INSTALL CORRECTLY! The installation should be made by a qualified installer. Specific tools may be required for installation purposes dependant upon the site in which the assembly is to be installed. Use the appropriate tools. Refer to local and national standards for wiring and follow recommendations. The installation should be in compliance with local codes. Check that correct cable types are used.

WARNING: This apparatus must be connected to Earth!


An appropriate disconnection device must be fitted when installing electrical supply. Always disconnect and remove the power before working on the installation. Ensure the power CANNOT be re-connected by external sources while the unit is being worked upon. PREVENTATIVE MAINTENANCE! Although the unit contains no user serviceable parts it is recommended that the following checks be carried out on a routine basis; 1. One month after installation and every six months thereafter, check the tightness and security of all external fastenings (i.e. the whole CCTV installation). 2. Every six months check electrical cables for signs of wear. Replace where necessary. Regular checks should be performed to ensure that the cables are not fouling on any obstruction.

Page 1 of 10

ISSUE : 7
November 1997

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER

INSTALLATION INSTRUCTIONS

17 Function Preset AC Telemetry Receiver


INSTALLATION INSTRUCTIONS
General Description
The TRX228/TRX229 telemetry receivers are available either as circuit board only or a completed assembly inside an IP55 weatherproof enclosure or the IP66 rated Connoisseur housing (Fig.1.) in several voltage options. Each receiver unit is supplied with either a C (coaxial) or D (twisted pair) telemetry receiver module (Molynx Part No.s ~ PLW231, PLW233). The receivers are compatible with either of the following Molynx telemetry transmission systems; 600 Series Visilynx II. The TRX229 2 function telemetry receiver is ideal for outdoor static camera RX8H55 assemblies which require a wash/wipe facility and is as standard powered from a supply of 230V AC with options of 24V AC output and 110V AC input. The TRX228 10 function telemetry receiver is ideal for outdoor, fixed speed, AC PTZ camera systems. Additional options include Random Autopan function. The Pan, Tilt and User functions can be supplied with options of 24V or, 110120V or, 230-240V AC @ 50-60Hz. RX9H44 The circuit boards are powered from a 12V DC PSU (fitted as standard in all enclosures), that supplies all lens functions. This unit requires a 4-wire lens system. Each internally mounted receiver assembly includes its own power supply unit used for mains supply input and 12V DC output to power the PCB. There is also a 12V DC auxiliary supply via a 5.5mm jack socket (spare jack plug supplied) as well as a 3 pin AC auxiliary supply (rated at mains input voltage), either of which may be used to power a camera assembly. A Test button provides a comprehensive test facility to ease installation and maintenance. This manual covers all enclosure and voltage options. Examples of each are explained throughout the document with wiring options explained.
FIG.1.

Notes: 1. A 12V DC PSU is supplied with all housing and boxed versions. This is pre-wired to the receiver board. The AC mains supply only, should be applied to the receiver. Connect via terminal block 4, which is pre-wired to supply CN2 (terminals 1, 2 and 3) with an AC supply (refer to FIGs.4 and 5, pg5). 2. The lens functions i.e. ZOOM and FOCUS, speed up gradually when the transmitter key is held down. This enables precise positioning of the lens by the operator.

Contents Of Box
Receiver Built into a Connoisseur Housing: e.g. ~ TRX228/Connoisseur Assembly ~ RX8H55C240. 1 off Connoisseur Installation Instructions (INS00126) 1 off Receiver Installation Instructions (INS00054) 4 off M6 Plain Washers 4 off M6 x 12 Hex. Head Screws 1 off 4mm AF Allen Key - ZW322A 1 off " (6mm thick) Spacer Block - ZF331 1 off 1/8" (4mm thick) Spacer Block - ZF332 1 off 1/16" (3mm thick) Spacer Block - ZF333 1 off Nylon Shoulder Washer - ZW324A 1 off 1/4" BSW x 3/8 Hex. Head Screw 1 off 1/4" BSW x Hex. Head Screw Receiver Built into IP55 Boxed Unit: Receiver/Weatherproof Box Assembly Blanking Plugs and Screws Installation Instructions (INS00054) Receiver Board Only: Assembled Receiver Board 4 x Stick-on Board Mounting Pillars 4 x Screw-on Board Mounting Pillars Installation Instructions (INS00054) Note: Before/During Installation of the Assembly Unit Ensure That; 1. The contents of box are correct. 2. The installation instructions are read thoroughly. 3. The correct tools are used when installing. 4. The complete assembly is mounted and tested in the workshop prior to use on site. (This can reduce the installation time considerably.)

DO NOT CARRY OUT ELECTRICAL INSTALLATIONS IN WET WEATHER CONDITIONS

Page 2 of 10

ISSUE : 7
November 1997

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER

INSTALLATION INSTRUCTIONS

TELEMETRY OPTIONS
Molynx AC telemetry receivers offer both COAXIAL ("C" Type) and TWISTED PAIR ("D" Type) telemetry options. NOTE: The majority of video amplifiers cannot be used with "C" type telemetry. However, Molynx can supply a Video Amplifier that can be used with "C" type telemetry. Always keep telemetry cables as short as possible to prevent/reduce R.F interference.

C Type Transmission (coaxial cable)


Video and telemetry signals travel down the same cable in different directions at different frequencies.

Recommendation - For ease of use, when connecting coaxial cables to this unit use right-angled (90) BNC plugs. Signal Specification: 11.50MHz carrier modulated @ 9600 baud. Cable Recommendations: Video and Telemetry signals travel down the same cable in different directions at different frequencies. Telemetry will operate with link losses up to 26dB @ 11.50MHz. Most video pictures will be severely impaired with a loss greater than 6dB in the cable. Choose an appropriate coaxial cable to give an acceptable loss (in dB) for the required distance. Refer to data supplied by cable manufacturers for further information and NACOSS (NACP20) guidelines for greater technical detail. Typical distance: 500 metres (longer distances possible using a high specification cable). Note: For fixed cameras it may be necessary to use a Molynx RF rejector unit (VT148) at the camera assembly to prevent the telemetry signal interference with the video picture.

D Type Transmission (twisted pair)


Signal Specification: Cable Recommendations: Typical distance: EIA RS485 electrical interface, uni-directional @ 9600 baud. Twisted pair cable is essential for the telemetry signals with all video signals using coaxial cable. 3km maximum transmission distance with a suitably rated cable, e.g. Belden 8205 twisted pair. For distances below 1km, most twisted pair cable will be suitable Refer to cable manufacturers data for further information and NACOSS (NACP20) guidelines for greater technical detail. Refer to technical specification TS-060-2 for information regarding RS485 cabling guidelines.

FIG.2. Telemetry Sub-boards

Terminating Jumper JP1

The receiver units can be ordered with a C type (coaxial) or D type (twisted pair) sub-board. These plug-in modular circuit boards can be interchanged on-site. Use plug-in module PLW231 if you require D type control or, use PLW233 for C type telemetry. (Refer to page 4, for installation guidelines).

Termination of RS485 transmission network


Termination of an RS485 communications network is achieved using the jumper connector supplied with PLW231 (twisted pair) D type sub-board. It is important to match the impedance of the load to the characteristic impedance of the transmission line so that the receiver absorbs the signal and does not reflect stray signals, which may disrupt the data. That is why the two furthest ends of the transmission line must be terminated in a "daisy chain" network. The PLW231 has a 120-Ohm terminating resistor in circuit with JP1. When the jumper connector is not in use simply position the jumper onto one pin of JP1 for safekeeping. Receivers can be supplied as a stand-alone board, or a pre-wired assembly within a weatherproof box or camera housing.

Page 3 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER Fitting Optional Telemetry Sub-boards


FIG.3.

INSTALLATION INSTRUCTIONS

M3 x 6mm Mounting Screw

M3 x 6mm Mounting Screw

As an additional option the telemetry modules (coaxial or twisted pair) may be changed.

Remember; always ensure power is disconnected before working on this unit!


Change the module as follows; 1. Release the information overlay that covers the PCB, from the four PCB spacers (TRX228 only). 2. Remove the M3 x 6mm cheese head and M3 fibre washer from the supporting hex. spacer and unplug the module from the five pin header socket (CN 4). 3. The output terminal for the telemetry module is CON1. Plug module CON1 into place on the receiver, CN4 and secure using the M3 x 6mm cheese head and M3 fibre washer. The supporting hex. spacer when fitted correctly acts as an earth connection for the new module. (Do not place the fibre washer on the under side of the new module.) 4. Replace the information overlay (TRX228 only).

Connection Details
Cable Recommendations
Notes: ALWAYS CHECK VOLTAGE LABELS BEFORE APPLYING POWER TO THE UNIT. The recommended mains cable for all units is 0.75mm (24/0.2mm). The mains supply MUST be fused at 5Amps. For 230/240v AC units a minimum conductor size of 0.5mm can be used, provided the supply is fused at 3Amps or less. (It is recommended that this cable be kept to less than 3 metres due to the high current.) When connecting cables for the electrical supply ALWAYS ensure that High (mains) voltage conductors are separated from Low voltage (telemetry, lens, etc.) conductors. Where conduit is not used, do not insert more than one cable per cable gland to ensure weatherproofing. Note: Ensure that Cable Glands are sealed securely to prevent the ingress of moisture into the unit. Recommended Pan/Tilt unit cable 24/0.2mm, (0.75mm) Olflex YY PVC insulated, grey PVC sheathed, 7 core (6 + Earth), 8.1mm nominal, or similar. 16/0.2mm, (0.5mm) minimum conductor size @ 230/240v 3A. (Note: It is recommended that this cable is kept as short as possible due to the high current.) Pan and tilt motor cable minimum conductor size 16/0.2mm. Lens functions: 7/0.2mm with overall screen. Note: Always keep cables as short as possible to prevent/ reduce R.F interference. Electrical installation methods should comply with current national regulations and site regulations. Technicians qualified to the appropriate level should only carry out the installation. An appropriate disconnection device MUST be included in the installation. Prior to commencement of installation, all relevant safety requirements must be adhered to. These will vary with the nature of the site and may involve specialist installation equipment when working in hazardous areas. Cable Glands Fuse Ratings (Insert only one cable per cable gland to ensure weatherproof IP66 rating) Main Assembly :5Amps 2 x 20mm cable glands 2 x 16mm cable glands Power Supply :2A Cable range 8mm to 13mm (diameter) Cable range 7mm to 10.5mm (diameter). PCB Fuse :2A anti-surge

Page 4 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER Supply Inputs


Boxed unit: Board only:

INSTALLATION INSTRUCTIONS

The Pan/Tilt and Auxiliary functions can be supplied with 24V or, 110-120V or, 230-240V AC @ 50-60Hz. 12V DC is pre-wired to supply all lens functions. Unregulated 12V DC to supply board and all lens functions. 24V or, 110-120V or 230-240V AC, which is, supplied to all mains functions via terminal block. ALWAYS CHECK VOLTAGE LABELS BEFORE APPLYING POWER TO THE UNIT

Important Note: The boards have two LED indicators: GREEN Valid data indicator, when lit continuously (i.e. no flickering), indicates that valid data is being received from the transmitter unit. If the GREEN LED flickers corrupt data is reaching the receiver. RED Power-on indicator when lit indicates power is being applied to the board. Note ~ If this happens switch OFF the power and check all wiring before re-powering unit. Circuit Description IC1 is the processor and controller. All functions received 2. The AC mains input supply should be applied to the receiver power supply via terminal block 4. This is previa the telemetry input are interpreted and switched onto ports P0 and P2, then through IC2 and IC3 onto wired to supply the receiver via CN2 (terminals 1, 2 connectors CN2 and CN3. IC4 is a simple watchdog that and 3). The AC voltage applied on the L E N terminals resets if the power supply drops below a certain voltage. of CN2 is the voltage that appears as the switched outputs on PR, PL, TU, TD, USR1 and USR2. Notes: Breaking links JP1 and JP2 on the rear of the PCB allocates voltage free relay contacts for terminal 1. The receiver boards are powered from an unregulated USR2. 12v DC power supply (polarity is not important) situated under the chassis (fitted as standard in all 3. The lens functions i.e. ZOOM and FOCUS speed up gradually (12v DC ramped output) when the boxed enclosures and housings). This is pre-wired to transmitter key is held down. This enables precise the receiver board via CN1 and is supplied as a positioning of the lens by the operator. The power ramped output to all lens functions (ZI, ZO, FN and supply has a 12v DC 420mA auxiliary output via a jack FF) on connector CN3. This voltage is then regulated socket to power a camera or other equipment. by RG1 down to 5v DC for the digital supply.

Receiver Layout
1. 2. The polarity of the 12V DC input is NOT important (pre-wired in boxed versions). 24V, 110V or 240V AC applied to terminals 1, 2 and 3 of the main terminal block is supplied to the appropriate function when operated from the transmitter (on boxed version, the AC supply is pre-wired to the main terminal block). Breaking links JP1 and JP2 on the rear of the receiver board results in USR2 becoming a voltage-free contact. FIG.4.a

3.

TRX229: 2 Function Receiver Board Note:


1. 12V DC 420mA output is available on the mains input terminal block. 2. A 2Amp fuse protects the PSU with a 2Amp anti-surge fuse to protect the Main PCB.

AC Functions

24V to 230V

Page 5 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER

INSTALLATION INSTRUCTIONS

FIG.4.b Key 1. 12V DC AUX O/P for camera. 2. 12V DC supply to PCB. 3. AC AUX O/P supply. (L, E, N) 4. Video input from camera. 5. C Type Control input / Video output. 6. Mains AC supply input. (L, E, N) 7. Spare 16mm cable gland (blank) 8. Spare 20mm cable gland (blank) 9. 20mm Conduit 10. Wiper motor supply connections 11. Power supply fuse. 12. Earth point

TRX228: 10 Function Receiver Board Note:


1. With the 24V AC option the box is supplied with 230V AC and 24V is pre-wired to the TRX228 board. A 24V AC output is available from the mains input terminal block. 2. 12V DC 400mA lens output is available on the mains input terminal block. The PSU is protected by a 2Amp fuse with a 2Amp anti-surge fuse protecting the main PCB.

FIG.5.a

AC Functions

24V to 230V

Page 6 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER

INSTALLATION INSTRUCTIONS

FIG.5.b Key: 1. 12V DC AUX O/P for camera. 2. 12V DC supply to PCB. 3. AC AUX O/P supply. (L, E, N) 4. Video input from camera. 5. C Type Control input/Video output. 6. Mains AC supply input. (L, E, N) 7. Spare 16mm cable gland (blank) 8. Spare 20mm cable gland (blank) 9. 20mm Conduit 10. Pan/Tilt control cable 11. Power supply fuse. 12. Earth point

4 wire to 3 wire Lens Converter


The TRX228 telemetry receiver requires a four-wire lens system i.e. two wires from each motor (zoom, focus, with no common connection). The diagram represents lens/receiver interconnections. A 4 wire to 3 wire lens converter module VT234 is available from Molynx Ltd, Part No. ~ PCBT234. Notes: 1. Connect wires to the terminals as labelled, i.e. ZI (ZOOM IN) to ZI, etc. 2. Connect wires from the 12V DC (unregulated) 5.5mm jack socket to the terminals "12V" and "GND" on the VT234 box via the spare jack plug (supplied). 3. The VT234 converter box must not be fitted externally to the housing or enclosure, as it is not weatherproof.

FIG.6

Page 7 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER Pan and Tilt Unit Connection to Receiver. Notes: Refer to Pan/Tilt Unit instructions ~ INS00053.

INSTALLATION INSTRUCTIONS

Standard 7 Pin Control Cable Connector Detail For Molynx Mustang 12 AC Pan and Tilt Unit
1. 2. 3. 4. 5. 6. 7. NEUTRAL PAN RIGHT PAN LEFT TILT UP TILT DOWN N/U. (Autopan). EARTH

FIG.7

Video and Telemetry Transmission Connection (i.e. Camera/Transmitter to Receiver.)


Video from camera: CAM (BNC on receiver module PLW233). Note: A switched AC supply is available to the camera via the USR2, AUX1 setting. This enables the operator to switch the camera ON and OFF via the transmitter. Connect the camera mains input to CAM and NEUT. Coaxial cable (C type data transmission) from transmitter : LINE (BNC on receiver module) OR, Twisted Pair cable from transmitter (D type data transmission) : + and - (2-pin connector module PLW231). Note: The valid data indicator will light to indicate data reaching the receiver unit.

Test Modes
Individual Test
To test each function in individually set SW1 to the function you require from 1 through to A and press the test button SW4. The function associated with the switch position will operate. Address Switch Sw1 Test Sequence 1. Pan Right 2. Pan Left 3. Tilt Up 4. Tilt Down 5. USR 1 6. USR 2 7. Zoom In 8. Zoom Out 9. Focus Near A. Focus Far Examples; SW1 set to 4, SW4 test button pressed; TILT DOWN operates FIG.8 SW1 set to 5, SW4 test button pressed; USR 1 function operates SW1 set to A, SW4 test button pressed; FOCUS FAR operates

Automatic Function Tests


Turn Address switch SW1 to 0 and press the test button SW4. All receiver functions will be sequentially activated automatically for approximately 5 seconds in the following order.

Position 0

Self test Pan Right Pan Left Tilt Up Tilt Down USR 1

USR 2 Zoom In Zoom Out Focus Near Focus Far

Page 8 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER Addressing the Receiver (channel / camera No.)

INSTALLATION INSTRUCTIONS

Address Settings For Molynx Telemetry Receivers


Receiver / Camera addresses can be set from 1 to 256 using SW1 and SW2. (SW2 sets the bank of 16 receivers.) The table shown is an example and represents just a small number of the addresses. The table and the examples below explain st 1 bank of 16 the switch settings for various addresses. Examples; Address 35 : SW1=2 SW2 = 2 (SW2 denotes 2nd bank of 16) Address 117 : SW1=4 SW2=7 nd 2 bank of 16 (SW2 denotes 8th bank of 16) Address 256 : SW1=F SW2=F (SW2 denotes 16th bank of 16)

TROUBLE SHOOTING and TESTING


PCBs leave the factory fully tested and operational, if a fault does occur check all system interconnections before assuming faulty electronics. Check the twisted pair/coaxial cable between the PTZ and the telemetry receiver unit. Ensure correct inter-connection between telemetry receiver and the controller. Verify link and switch settings are correct. Ensure all cable connections to external equipment are secure and there are no short circuits between the pins. 1. a) b) Has the RED POWER ON LED illuminated? Check FUSE 1: 2A 250V HRC 20mm. c) Ensure PINS 1 of RG1 regulator is supplied with +12v Ensure PINS 1 & 2 of CN1 are providing 12v DC DC. unregulated supply. d) Ensure +5v DC supply on PIN 1 of telemetry module CON1. Has the GREEN VALID DATA LED illuminated? Check the coaxial or twisted pair signal cables have i.e. C type: BNC from camera to CAM, BNC from been installed correctly. transmitter to LINE D type: +ve data to + terminal, -ve data to - terminal (reverse twisted pair for a quick check). Carry out the INDIVIDUAL TEST ROUTINES (pg8) to ensure all external connections are correct. Note: Fuse 3 - 2A anti-surge (only applicable with receivers mounted inside enclosures).

2.

3.

Nothing operates at all Check there is power to the board on CN2 (L, E, N). If there is no power check that the correct mains has been applied to the chassis terminal block (L, E, N) and that the pre-wired connections are not loose or damaged. Check the chassis fuse (5A @ 250V). If there is power to the board check the receiver test functions (pg8). Check for 12V DC at CN3 when a lens function is activated from the transmitter. Video present - no control Ensure the valid data indicator is lit continuously (GREEN LED). If it does not light up after data wires have been connected; 1. When using D type data reverse the twisted pair. (i.e. swap over the +'ve and -'ve data at the receiver.) 2. When using C type data - Ensure the coaxial cable from the transmitter and the camera have been installed correctly. If reversed you will receive a video picture but no control. Connect Coaxial cable from camera to CAM and from transmitter to LINE.

If All The Above Checks Have Been Carried Out And The Card Is Still Not Functioning Correctly Please Contact Our Technical Support Department.

Page 9 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER

INSTALLATION INSTRUCTIONS

SPECIFICATIONS
TRX228

TRX229

WEATHERPROOF BOX

DIMENSIONS (mm)
Printed circuit board External Dimensions of HW550 camera housing External Dimensions of HW440 camera housing TRX228 TRX229 L 100 101 617 567 W 102 60 168 168 H Weight 30(max) 80 g 30 (max) 80 g 148 6 kg with sunshield 148 6 kg with sunshield

Cable Gland Sizes 2 x16mm : cable range 7 - 10.5mm 2 x13mm : cable range 2 - 5mm

Internal Dimensions (RX8H55). 468 110 95 4.5 kg (with TRX228 fitted in extended housing) without sunshield Weatherproof box TRX228/229 220 168 86 1.5kg

Electrical Specifications
Power Requirements: 230V AC, 50/60Hz @ 20VA
Optional, 110-120V 50/60Hz @ 20VA or, 24V AC @ 100 VA max.

Boxed units: 230-240/110-120V AC @ 6 VA (voltage labels fitted on all units). Board: TRX229: 12V DC @ 80mA TRX228: 12V DC @ 100mA + lens consumption (check lens specification).

Mains Cable: Recommended minimum : 0.75mm (Supply fused at 6Amps or less.). Fuse Ratings: Main Assembly: 5Amps Auxiliary Functions: 2A Pan and Tilt Functions: 2A

Mechanical Specifications
Material: Box - IP66 polycarbonate enclosure (incl. lid & fixings) Mounting Details: Box - 4 x 6.5mm dia. holes PCB 4 x 4mm dia. holes. Shock: 30G Max. (packed product). Operational: Operating temperature: -20C to +40C. (Ta = +25C). Relative Humidity: 95% non-condensing. Weatherproof standard: BS EN 60 529 Enclosure: IP55, Housing: IP66, MTTR: 30 Mins MTBF: 30,000hrs at Ta. Air Pressure: operating range within 70 to 110 Kpa Vibration: suitable to IEC 68-2-6 Fc5g Electrostatic Discharge: rated at IEC 801-2 level 3

FUNCTIONS
TRX228 - Pan, Tilt, Zoom, Focus, a choice of 2 user selectable auxiliary functions. TRX229 - 2 user selectable options from the table shown. Self test facility covering all functions. LED indicators; Green, Valid data from transmitter. Red, PSU indicator. AUX1 terminals provide a set of voltage free changeover contacts. (N/O, N/C & Common).

CONTROL OUTPUTS
TRX228 - 230-240/110-120V AC input switched to pan/tilt and two user selectable functions. Maximum load capacity 1A per function. 12V DC for lens functions @ 50mA (MAX.) per function. TRX229 - 24-240V AC input switched to pan/tilt and two user selectable functions. Maximum load capacity: 1A per function.

Page 10 of 10

ISSUE : 8
November 1999

INS00054

TRX228 / 229 ~ AC TELEMETRY RECEIVER


Additional Information

INSTALLATION INSTRUCTIONS

INS00054

November 1997

ISSUE : 8

You might also like