Protocol Driver

FieldServer Driver - Serial


FS-8700-60

Gardner Denver Auto Sentry ES / RS2000


Description The Gardner Denver Auto Sentry ES / RS2000 driver allows the FieldServer to transfer data from devices over either RS-232 or RS-485 using Gardner Denver Auto Sentry ES / RS2000 protocol. The driver can be set to communicate with ES controllers with software versions V2.0X, V2.1X and RS2000 controllers. The client driver implements the following functionality: Polls controllers for service and maintenance data. Polls controllers for operating mode data. Polls controllers for operating data. Fieldserver Mode Client Formal Driver Type Serial Client Only Compatibility Matrix FieldServer Model FS-B2010 FS-B2011 FS-B40 Connection Information Connection type: Baud Rates: Data Bits: Stop Bits: Parity: Multidrop Capability RS-232 or RS-485 (Two wire, Half-Duplex) 1200; 9600; Baud 7,8 1,2 Odd, Even, None Yes Compatible with this driver Yes Yes Yes Nodes 1 Comments A client node can communicate with up to 8 controllers

FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldserver.com Website: www.fieldserver.com Page 1 of 4

Protocol Driver

Devices tested Device AUTO Sentry ES RS2000 Connection configurations Tested (FACTORY, SITE) Site Site

Connection Notes None

FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldserver.com Website: www.fieldserver.com Page 2 of 4

Protocol Driver

Communications functions - Supported functions at a glance: Read Operations supported FieldServer as a Client Read Service and Maintenance Data Advisories Shutdown codes Total runtime hourmeter readings @ shutdown codes Current total runtime hourmeter reading Current loaded runtime hourmeter reading Current temp hourmeters Stored temp hourmeters Last maintenance A Last maintenance B Oilage Read Operating Mode Data Operating mode indication * Sequence number * Unit operating state * Only RS2000 & ES V2.10 and later software versions Read Operating Data System pressure Filter pressure Discharge temperature Reservoir temperature * Motor current * Not for RS2000 Unsupported Functions and Data Types Function Programming messages Reason FieldServer is a data transfer device, and as such, programming messages are not required

FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldserver.com Website: www.fieldserver.com Page 3 of 4

Protocol Driver

Revision History Doc. Rev. 0 1 2 3 4

Date 6/19/02 8/14/03 4/09/04 6/12/04 12/29/04

Resp JD DR DR JD

Format Driver Ver. 1.00a 1.00a 1.02a 1.02a 1.02a

Comment Releasing Releasing Updated with other controllers supported Updated connection diagram Releasing

DR DR

FieldServer Technologies, 1991 Tarob Court, Milpitas, CA 95035 USA Tel: 408-262-2299, Fax: 408-262-9042 Toll-Free: 888-509-1970 Email: sales@fieldserver.com Website: www.fieldserver.com Page 4 of 4